Sample records for ultrasonography diagnostic role

  1. Role of ultrasonography in the differential diagnosis of thyrotoxicosis: a noninvasive, cost-effective, and widely available but underutilized diagnostic tool.

    PubMed

    Alzahrani, Ali S; Ceresini, Graziano; Aldasouqi, Saleh A

    2012-01-01

    To explore the use of ultrasonography as a diagnostic alternative to the traditional "gold standard" imaging study of nuclear scintigraphy in the evaluation of thyrotoxicosis. We review the relevant literature and share our own experience to highlight the promising role of ultrasonography in thyrotoxicosis. In addition, we present a diagnostic algorithm suggesting liberal use of ultrasonography in the evaluation of thyrotoxicosis. Ultrasonography has proved effective not only in the differentiation of Graves disease from other types and causes of thyrotoxicosis but also in the detection of subtle thyroid nodules. The latter role is emphasized in light of the recent observation of an increased risk of occurrence of papillary thyroid carcinoma in patients with Graves disease. Ultrasonography is a cost-effective, noninvasive, portable, and safe imaging modality in the evaluation of thyrotoxicosis, both for physiologic assessment and for detection of nonpalpable thyroid cancers that may elude identification on physical examination and nuclear imaging studies. Although thyroid scintigraphy remains a standard radiologic study, thyroid ultrasonography can be a practical alternative in many cases and the primary imaging modality in some situations such as during pregnancy and lactation and for evaluation and management of amiodarone-induced thyrotoxicosis.

  2. [Vascular complications following kidney transplant: the role of color-Doppler imaging].

    PubMed

    Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale

    2012-01-01

    The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.

  3. The role of diagnostic ultrasound as a new diagnostic aid in oral and maxillofacial surgery

    PubMed Central

    Venkataraman, Siva Subramaniyam; Aravind, Ramraj Jayabalan; Kavin, Thangavelu

    2012-01-01

    Only very few studies have been done in the past to evaluate the usefulness and limitations of ultrasonography in oral and maxillofacial surgery. This study, though in an embryonic stage, has been done to bring this technique to limelight and to put forth the importance of its use and limitations in the branch of oral surgery. The purpose of this study was to investigate and study the characteristic pattern of the oral tissues on gray scale ultrasonography and to assess the practical applicability of this new diagnostic technique in diagnosing various tissue pathologies in the field of oral and maxillofacial surgery. PMID:23066231

  4. [Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].

    PubMed

    Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia

    2012-01-01

    Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.

  5. Role of endoscopic ultrasonography in evaluation of metastatic lesions to the pancreas: a tertiary cancer center experience.

    PubMed

    Atiq, Muslim; Bhutani, Manoop S; Ross, William A; Raju, Gottumukkala S; Gong, Yun; Tamm, Eric P; Javle, Milind; Wang, Xuemei; Lee, Jeffrey H

    2013-04-01

    Metastatic lesions to the pancreas pose diagnostic challenges with regards to their differentiation from primary pancreatic cancer. Data on the yield of endoscopic ultrasonography (EUS)-guided fine-needle aspiration in detection of these lesions are limited. This is a retrospective review of 23 patients referred to a tertiary referral center for further evaluation of suspected pancreatic metastases. Main outcome measures were diagnostic yield of endoscopic ultrasonography-guided fine-needle aspiration in evaluation of metastatic lesions to the pancreas. Of 644 patients, 23 (3.6%) undergoing EUS of the pancreas were diagnosed to have metastatic disease to the pancreas based on clinical, radiological, and cytological results. Mean (SD) age was 64.3 (11.7) years. Of the 23 patients, 18 (78.3%) were asymptomatic. Mean (SD) size of lesion on EUS was 39.1 (19.9) mm. A diagnosis of malignant lesion was made in 21 of 23 cases, with a diagnostic accuracy of 91.3%. Metastatic lesions to the pancreas present as incidental, solitary mass lesions on staging or surveillance imaging. Endoscopic ultrasonography-guided fine-needle aspiration is an important tool in the characterization and further differentiation of metastatic lesions to the pancreas from primary pancreatic cancer.

  6. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no difference between the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy according to the internal composition of the lesions. There were no complications requiring intervention or hospitalization in our patients. Ultrasonography-guided core needle biopsy is superior to ultrasonography-guided fine-needle aspiration in detecting and characterizing malignant tumors of the salivary gland and could emerge as the diagnostic method of choice for patients presenting with a salivary gland mass. © 2015 by American Journal of Neuroradiology.

  7. Imaging of thyrotoxicosis.

    PubMed

    Sipos, Jennifer A; Kahaly, George J

    2012-09-01

    The diagnostic algorithm for patients with Graves' disease frequently involves the use of thyroid autoantibody testing and radioisotope scanning (full text available online: http://education.amjmed.com/pp1/248). However, ultrasound has myriad uses in the evaluation of patients with hyperthyroidism. The purpose of this paper is to review the medical literature outlining the important role that ultrasonography (US) can play in the diagnosis and management of patients with hyperthyroidism. We will make a case for the use of ultrasonography in the initial evaluation of all patients with thyrotoxicosis. This review will delineate the advantages of ultrasonography compared to nuclear medicine imaging in determining the etiology of the hyperthyroidism. The role of sonography in predicting remission and relapse of Graves' disease will also be examined. Finally, this paper will detail the importance of ultrasonography in the workup of hyperthyroidism during pregnancy. We will also outline its utility for predicting fetal thyroid dysfunction in maternal Graves' disease without the need for cordocentesis and its attendant complications. Copyright © 2012. Published by Elsevier Inc.

  8. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    PubMed

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  9. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    PubMed Central

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  10. Diagnostic utility of abdominal ultrasonography in dogs with chronic vomiting.

    PubMed

    Leib, M S; Larson, M M; Panciera, D L; Troy, G C; Monroe, W E; Rossmeisl, J H; Forrester, S D; Herring, E S

    2010-01-01

    Chronic vomiting is a common problem in dogs that has many causes. Ultrasonographic descriptions of many gastrointestinal (GI) diseases have been published. However, diagnostic utility of ultrasonography in dogs with chronic vomiting has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. Eighty-nine pet dogs with chronic vomiting. Medical records were reviewed and the contribution of abdominal ultrasound to the clinical diagnosis was subjectively scored. In 68.5% of dogs, the reviewers thought that the same diagnosis would have been reached without performing ultrasonography. In 22.5% of dogs, the ultrasound examination was considered to be vital or beneficial to the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with increasing age, a greater number of vomiting episodes per week, presence of weight loss, a greater percentage of lost body weight, and a final diagnosis of GI lymphoma or gastric adenocarcinoma. However, multivariate analysis only identified increasing age and a final diagnosis of gastric adenocarcinoma or GI lymphoma to be associated with increased diagnostic utility. In 12.4% of dogs, additional benefits of ultrasonography to case management, excluding the contribution to the vomiting problem, were identified. The diagnostic utility of abdominal ultrasonography was high in 27% of dogs. The presence of factors that are associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic vomiting.

  11. Diagnostic utility of abdominal ultrasonography in dogs with chronic diarrhea.

    PubMed

    Leib, M S; Larson, M M; Grant, D C; Monroe, W E; Troy, G C; Panciera, D L; Rossmeisl, J H; Werre, S R

    2012-01-01

    Chronic diarrhea is common in dogs and has many causes. Ultrasonographic descriptions of many gastrointestinal diseases have been published, but the diagnostic utility of ultrasonography in dogs with chronic diarrhea has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. 87 pet dogs with chronic diarrhea. Prospective study in which medical records were reviewed and contribution of abdominal ultrasound toward making diagnosis was scored. In 57/87 (66%) of dogs, the same diagnosis would have been reached without ultrasonography. In 13/87 (15%) of dogs, the ultrasound examination was vital or beneficial to making the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with weight loss (P = .0086), palpation of an abdominal or rectal mass (P = .0031), diseases that commonly have mass lesions visible on ultrasound examination (P < .0001), and a final diagnosis of GI neoplasia. Multivariable regression indicated that utility of abdominal ultrasonography would be 30 times more likely to be high in dogs in which an abdominal or rectal mass was palpated (odds ratio 30.5, 95% CI 5.5-169.6) (P < .0001) versus dogs without a palpable mass. In 15/87 (17%) of dogs, additional benefits of ultrasonography to case management, independent of the contribution to the diagnosis of diarrhea, were identified. Overall, the diagnostic utility of abdominal ultrasonography was low in dogs with chronic diarrhea. Identification of factors associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic diarrhea. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  12. [The role of ultrasonography in the investigation of male infertility].

    PubMed

    Fejes, Zsuzsanna; Pásztor, Norbert; Karczagi, Lilla; Brzózka, Ádám; Király, István; Morvay, Zita; Palkó, András

    2018-05-01

    Unintended childlessness affects approximately 9-15% of couples in the reproductive age. It is known that a remarkable proportion of infertility is caused by the disorders of the male reproductive functions. Diagnostic imaging methods and especially ultrasonography play a crucial role in the infertility work-up, the ultrasound examination has become the method of choice for imaging in diseases affecting the testis. With the development of high resolution transducers and technology using colour Doppler, pulsed Doppler, share wave elastography and strain elastography, it is now possible to make accurate diagnoses. However, the place of the new imaging methods in the algorithm of infertility check-up should be clearly defined. Orv Hetil. 2018; 159(21): 815-822.

  13. Accuracy of Four Imaging Techniques for Diagnosis of Posterior Pelvic Floor Disorders.

    PubMed

    van Gruting, Isabelle M A; Stankiewicz, Aleksandra; Kluivers, Kirsten; De Bin, Riccardo; Blake, Helena; Sultan, Abdul H; Thakar, Ranee

    2017-11-01

    To establish the diagnostic test accuracy of evacuation proctography, magnetic resonance imaging (MRI), transperineal ultrasonography, and endovaginal ultrasonography for detecting posterior pelvic floor disorders (rectocele, enterocele, intussusception, and anismus) in women with obstructed defecation syndrome and secondarily to identify the most patient-friendly imaging technique. In this prospective cohort study, 131 women with symptoms of obstructed defecation syndrome underwent evacuation proctogram, MRI, and transperineal and endovaginal ultrasonography. Images were analyzed by two blinded observers. In the absence of a reference standard, latent class analysis was used to assess diagnostic test accuracy of multiple tests with area under the curve (AUC) as the primary outcome measure. Secondary outcome measures were interobserver agreement calculated as Cohen's κ and patient acceptability using a visual analog scale. No significant differences in diagnostic accuracy were found among the imaging techniques for all the target conditions. Estimates of diagnostic test accuracy were highest for rectocele using MRI (AUC 0.79) or transperineal ultrasonography (AUC 0.85), for enterocele using transperineal (AUC 0.73) or endovaginal ultrasonography (AUC 0.87), for intussusception using evacuation proctography (AUC 0.76) or endovaginal ultrasonography (AUC 0.77), and for anismus using endovaginal (AUC 0.95) or transperineal ultrasonography (AUC 0.78). Interobserver agreement for the diagnosis of rectocele (κ 0.53-0.72), enterocele (κ 0.54-0.94) and anismus (κ 0.43-0.81) was moderate to excellent, but poor to fair for intussusception (κ -0.03 to 0.37) with all techniques. Patient acceptability was better for transperineal and endovaginal ultrasonography as compared with MRI and evacuation proctography (P<.001). Evacuation proctography, MRI, and transperineal and endovaginal ultrasonography were shown to have similar diagnostic test accuracy. Evacuation proctography is not the best available imaging technique. There is no one optimal test for the diagnosis of all posterior pelvic floor disorders. Because transperineal and endovaginal ultrasonography have good test accuracy and patient acceptability, we suggest these could be used for initial assessment of obstructed defecation syndrome. ClinicalTrials.gov, NCT02239302.

  14. Portable duplex ultrasonography: A diagnostic and decision-making tool in reconstructive microsurgery.

    PubMed

    Gravvanis, Andreas; Karakitsos, Dimitrios; Dimitriou, Vasilios; Zogogiannis, Ioannis; Katsikeris, Nick; Karabinis, Andreas; Tsoutsos, Dimosthenis

    2010-07-01

    Unidirectional Doppler is a common diagnostic tool by the Reconstructive Microsurgeons; however, it may generate false signals and surely provides less imaging data as compared to duplex ultrasonography. We have reviewed the use of Portable Duplex Ultrasonography (PDU) in 16 patients who underwent complex soft-tissue/bone reconstruction, aiming to determine its role in the design and management of free tissue transfer. According to our data, there were modifications either of the surgical plan and/or of patient's management, based on PDU findings, in 10 out of 16 patients (62.5%). The use of ultrasound directed to subtle modifications in three patients (19%), but to significant changes of the surgical plan in four patients (25%). Also, the use of ultrasound improved significantly the postoperative management in three patients (19%). Thus, significant impact of PDU in patient's treatment was recorded in 44% of cases. Portable ultrasound represents generally available method for preoperative, intraoperative, and postoperative diagnosis and decision-making in free tissue transfer, hence could replace in the near future the unidirectional Doppler in the hands of Microsurgeons. (c) 2010 Wiley-Liss, Inc.

  15. The use of ultrasonography and digital mammography in women under 40 years with symptomatic breast cancer: a 7-year Irish experience.

    PubMed

    Redmond, C E; Healy, G M; Murphy, C F; O'Doherty, A; Foster, A

    2017-02-01

    Breast cancer in women under 40 years of age is rare and typically presents symptomatically. The optimal imaging modality for this patient group is controversial. Most women undergo ultrasonography with/without mammography. Young women typically have dense breasts, which can obscure the features of malignancy on film mammography, however, initial studies have suggested that digital mammography may have a more accurate diagnostic performance in younger women. Ultrasound generally performs well in this age group, although it is poor at detecting carcinoma in situ (DCIS). To evaluate the comparative diagnostic performance of ultrasonography and digital mammography in the initial diagnostic evaluation of women under 40 years of age with symptomatic breast cancer. Retrospective review of all women under the age of 40 years managed at our symptomatic breast cancer unit from January 2009 to December 2015. There were 120 patients that met the inclusion criteria for this study. The sensitivity of ultrasonography and digital mammography for breast cancer in this patient group was 95.8 and 87.5 %, respectively. The patients with a false negative mammographic examination were more likely to have dense breasts (p < 0.01). Five patients had a false negative ultrasonographic examination, withal of whom were diagnosed with DCIS detected by mammography. This study demonstrates the superior sensitivity of ultrasound for breast cancer in women under the age of 40 years, however, the results show that digital mammography has an important complimentary role in the comprehensive assessment of these patients, particularly in the diagnosis of DCIS.

  16. Extreme hydronephrosis due to uretropelvic junction obstruction in infant (case report).

    PubMed

    Krzemień, Grażyna; Szmigielska, Agnieszka; Bombiński, Przemysław; Barczuk, Marzena; Biejat, Agnieszka; Warchoł, Stanisław; Dudek-Warchoł, Teresa

    2016-01-01

    Hydronephrosis is the one of the most common congenital abnormalities of urinary tract. The left kidney is more commonly affected than the right side and is more common in males. To determine the role of ultrasonography, renal dynamic scintigraphy and lowerdose computed tomography urography in preoperative diagnostic workup of infant with extreme hydronephrosis. We presented the boy with antenatally diagnosed hydronephrosis. In serial, postnatal ultrasonography, renal scintigraphy and computed tomography urography we observed slightly declining function in the dilated kidney and increasing pelvic dilatation. Pyeloplasty was performed at the age of four months with good result. Results of ultrasonography and renal dynamic scintigraphy in child with extreme hydronephrosis can be difficult to asses, therefore before the surgical procedure a lower-dose computed tomography urography should be performed.

  17. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis.

    PubMed

    Yousefifard, Mahmoud; Baikpour, Masoud; Ghelichkhani, Parisa; Asady, Hadi; Shahsavari Nia, Kavous; Moghadas Jafari, Ali; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  18. Diagnostic Approach to Pediatric Spine Disorders.

    PubMed

    Rossi, Andrea; Martinetti, Carola; Morana, Giovanni; Severino, Mariasavina; Tortora, Domenico

    2016-08-01

    Understanding the developmental features of the pediatric spine and spinal cord, including embryologic steps and subsequent growth of the osteocartilaginous spine and contents is necessary for interpretation of the pathologic events that may affect the pediatric spine. MR imaging plays a crucial role in the diagnostic evaluation of patients suspected of harboring spinal abnormalities, whereas computed tomography and ultrasonography play a more limited, complementary role. This article discusses the embryologic and developmental anatomy features of the spine and spinal cord, together with some technical points and pitfalls, and the most common indications for pediatric spinal MR imaging. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    PubMed

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  20. An update on the role of advanced diagnostic bronchoscopy in the evaluation and staging of lung cancer

    PubMed Central

    Belanger, Adam R.; Akulian, Jason A.

    2017-01-01

    Lung cancer remains a common and deadly disease. Many modalities are available to the bronchoscopist to evaluate and stage lung cancer. We review the role of bronchoscopy in the staging of the mediastinum with convex endobronchial ultrasound (EBUS) and discuss emerging role of esophageal ultrasonography as a complementary modality. In addition, we discuss advances in scope technology and elastography. We review the bronchoscopic methods available for the diagnosis of peripheral lung nodules including radial EBUS and navigational bronchoscopy (NB) with a consideration of the basic methodologies and diagnostic accuracies. We conclude with a discussion of the comparison of the various methodologies. PMID:28470104

  1. Comparison of strain and shear wave elastography for qualitative and quantitative assessment of breast masses in the same population.

    PubMed

    Kim, Hyo Jin; Kim, Sun Mi; Kim, Bohyoung; La Yun, Bo; Jang, Mijung; Ko, Yousun; Lee, Soo Hyun; Jeong, Heeyeong; Chang, Jung Min; Cho, Nariya

    2018-04-18

    We investigated addition of strain and shear wave elastography to conventional ultrasonography for the qualitative and quantitative assessment of breast masses; cut-off points were determined for strain ratio, elasticity ratio, and visual score for differentiating between benign and malignant masses. In all, 108 masses from 94 patients were evaluated with strain and shear wave elastography and scored for suspicion of malignancy, visual score, strain ratio, and elasticity ratio. The diagnostic performance between ultrasonography alone and ultrasonography combined with either type of elastography was compared; cut-off points were determined for strain ratio, elasticity ratio, and visual score. Of the 108 masses, 44 were malignant and 64 were benign. The areas under the curves were significantly higher for strain and shear wave elastography-supplemented ultrasonography (0.839 and 0.826, respectively; P = 0.656) than for ultrasonography alone (0.764; P = 0.018 and 0.035, respectively). The diagnostic performances of strain and elasticity ratios were similar when differentiating benign from malignant masses. Cut-off values for strain ratio, elasticity ratio, and visual scores for strain and shear wave elastography were 2.93, 4, 3, and 2, respectively. Both forms of elastography similarly improved the diagnostic performance of conventional ultrasonography in the qualitative and quantitative assessment of breast masses.

  2. Comparison of the diagnostic value of ultrasonography and standing radiography for pelvic-femoral disorders in horses.

    PubMed

    Geburek, Florian; Rötting, Anna K; Stadler, Peter M

    2009-04-01

    To assess agreement between ultrasonography (transcutaneous and transrectal) and standing radiography in horses with fractures in the pelvic region and disorders of the coxofemoral joint. Case series. Warmblood horses (n=23) and 2 ponies. Medical records (1999-2008) of equids with pelvic or coxofemoral disorders that had pelvic radiography and ultrasonography were retrieved and results of both techniques compared. Radiography and ultrasonography each identified equal numbers of fractures of the tuber coxa (n=4), ilial shaft (2), ischium (3), femoral neck (2), and osteoarthritis/osis of the coxofemoral joint (6). Fractures of the ilial wing (4) were only identified by ultrasonography not by standing radiography. Of 9 acetabular fractures, 3 were identified on radiographs only, 5 were identified with both modalities. One pubic fracture was identified using ultrasonography and radiography. One acetabular and 1 pubic fracture were only diagnosed on necropsy. We found reasonable agreement (73%; 24/33) between ultrasonography and standing radiography for diagnosis of pelvic-femoral disorders. Ultrasonography was more useful for ilial wing fractures and radiography for acetabular fractures. Ultrasonography is a rapid, safe imaging technique for detecting disorders of the pelvic region with a high diagnostic yield and is a preferred initial approach in horses with severe hindlimb lameness.

  3. External ultrasonography of the neck does not add diagnostic value to integrated positron emission tomography-computed tomography (PET-CT) scanning in the diagnosis of cervical lymph node metastases in patients with esophageal carcinoma.

    PubMed

    Blom, R L G M; Vliegen, R F A; Schreurs, W M J; Belgers, H J; Stohr, I; Oostenbrug, L E; Sosef, M N

    2012-08-01

    One of the objectives of preoperative imaging in esophageal cancer patients is the detection of cervical lymph node metastases. Traditionally, external ultrasonography of the neck has been combined with computed tomography (CT) in order to improve the detection of cervical metastases. In general, integrated positron emission tomography-computed tomography (PET-CT) has been shown to be superior to CT or PET regarding staging and therefore may limit the role of external ultrasonography of the neck. The objective of this study was to determine the additional value of external ultrasonography of the neck to PET-CT. This study included all patients referred our center for treatment of esophageal carcinoma. Diagnostic staging was performed to determine treatment plan. Cervical lymph nodes were evaluated by external ultrasonography of the neck and PET-CT. In case of suspect lymph nodes on external ultrasonography or PET-CT, fine needle aspiration (FNA) was performed. Between 2008 and 2010, 170 out of 195 referred patients underwent both external ultrasonography of the neck and PET-CT. Of all patients, 84% were diagnosed with a tumor at or below the distal esophagus. In 140 of 170 patients, the cervical region was not suspect; no FNA was performed. Seven out of 170 patients had suspect nodes on both PET-CT and external ultrasonography. Five out of seven patients had cytologically confirmed malignant lymph nodes, one of seven had benign nodes, in one patient FNA was not performed; exclusion from esophagectomy was based on intra-abdominal metastases. In one out of 170 patients, PET-CT showed suspect nodes combined with a negative external ultrasonography; cytology of these nodes was benign. Twenty-two out of 170 patients had a negative PET-CT with suspect nodes on external ultrasonography. In 18 of 22 patients, cervical lymph nodes were cytologically confirmed benign; in four patients, FNA was not possible or inconclusive. At a median postoperative follow-up of 15 months, only 1% of patients developed cervical lymph node metastases. This study shows no additional value of external ultrasonography to a negative PET-CT. According to our results, it can be omitted in the primary workup. However, suspect lymph nodes on PET-CT should be confirmed by FNA to exclude false positives if it would change treatment plan. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  4. How useful is abdominal ultrasonography in dogs with diarrhoea?

    PubMed

    Mapletoft, E K; Allenspach, K; Lamb, C R

    2018-01-01

    To assess the utility of abdominal ultrasonography in the diagnostic work-up of dogs with diarrhoea. Retrospective cross-sectional study based on a referral population of dogs with diarrhoea. Associations between the clinical signs, use of abdominal ultrasonography, results of abdominal ultrasonography and subsequent work-up were examined. The utility of abdominal ultrasonography was scored as high, moderate, none or counterproductive based on review of medical records. Medical records of 269 dogs were reviewed, of which 149 (55%) had abdominal ultrasonography. The most frequent result was no ultrasonographic abnormalities affecting the intestine in 65 (44%) dogs. Ultrasonography results were associated with subsequent work-up as follows: (1) no detected abnormalities and dietary trial; (2) focal thickening of the intestinal wall, loss of intestinal wall layers or enlarged abdominal lymph nodes and ultrasound-guided fine-needle aspirates; (3) diffuse thickening of the intestinal wall or hyperechoic striations in the small intestinal mucosa and endoscopy; and (4) small intestinal foreign body and coeliotomy. Abdominal ultrasonography was considered to be diagnostic without further testing in only four (3%) dogs: two had a portosystemic shunt identified ultrasonographically, one had a linear foreign body and one had a perforated pyloric ulcer. Abdominal ultrasonography had moderate utility in 56 (38%) dogs and no utility in 79 (53%) dogs. Abdominal ultrasonography was considered counterproductive in 10 (7%) dogs because results were either falsely negative or falsely positive. These results should prompt clinicians to reconsider routine use of abdominal ultrasonography in dogs with diarrhoea. © 2017 British Small Animal Veterinary Association.

  5. An economic evaluation of second-trimester genetic ultrasonography for prenatal detection of down syndrome.

    PubMed

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T; Knuppel, R A

    1998-11-01

    The objective of this study was to perform an economic evaluation of second-trimester genetic ultrasonography for prenatal detection of Down syndrome. More specifically, we sought to determine the following: (1) the diagnostic accuracy requirements (from the cost-benefit point of view) of genetic ultrasonography versus genetic amniocentesis for women at increased risk for fetal Down syndrome and (2) the possible economic impact of second-trimester genetic ultrasonography for the US population on the basis of the ultrasonographic accuracies reported in previously published studies. A cost-benefit equation was developed from the hypothesis that the cost of universal genetic amniocentesis of patients at increased risk for carrying a fetus with Down syndrome should be at least equal to the cost of universal genetic ultrasonography with amniocentesis used only for those with abnormal ultrasonographic results. The main components of the equation included the diagnostic accuracy of genetic ultrasonography (sensitivity and specificity for detecting Down syndrome), the costs of the amniocentesis package and genetic ultrasonography, and the lifetime cost of Down syndrome cases not detected by the genetic ultrasonography. After appropriate manipulation of the equation a graph was constructed, representing the balance between sensitivity and false-positive rate of genetic ultrasonography; this was used to examine the accuracy of previously published studies from the cost-benefit point of view. Sensitivity analyses included individual risks for Down syndrome ranging from 1:261 (risk of a 35-year-old at 18 weeks' gestation) to 1:44 (risk of a 44-year-old at 18 weeks' gestation). This economic evaluation was conducted from the societal perspective. Genetic ultrasonography was found to be economically beneficial only if the overall sensitivity for detecting Down syndrome was >74%. Even then, the cost-benefit ratio depended on the corresponding false-positive rate. Of the 7 published studies that used multiple ultrasonographic markers for genetic ultrasonography, 6 had accuracies compatible with benefits. The required ultrasonographic accuracy (sensitivity and false-positive rate) varied according to the prevalence of Down syndrome in the population tested. The cost-benefit ratio of second-trimester genetic ultrasonography depends on its diagnostic accuracy, and it is beneficial only when its overall sensitivity for Down syndrome is >74%.

  6. Ultrasonography versus computed tomography for suspected nephrolithiasis.

    PubMed

    Smith-Bindman, Rebecca; Aubin, Chandra; Bailitz, John; Bengiamin, Rimon N; Camargo, Carlos A; Corbo, Jill; Dean, Anthony J; Goldstein, Ruth B; Griffey, Richard T; Jay, Gregory D; Kang, Tarina L; Kriesel, Dana R; Ma, O John; Mallin, Michael; Manson, William; Melnikow, Joy; Miglioretti, Diana L; Miller, Sara K; Mills, Lisa D; Miner, James R; Moghadassi, Michelle; Noble, Vicki E; Press, Gregory M; Stoller, Marshall L; Valencia, Victoria E; Wang, Jessica; Wang, Ralph C; Cummings, Steven R

    2014-09-18

    There is a lack of consensus about whether the initial imaging method for patients with suspected nephrolithiasis should be computed tomography (CT) or ultrasonography. In this multicenter, pragmatic, comparative effectiveness trial, we randomly assigned patients 18 to 76 years of age who presented to the emergency department with suspected nephrolithiasis to undergo initial diagnostic ultrasonography performed by an emergency physician (point-of-care ultrasonography), ultrasonography performed by a radiologist (radiology ultrasonography), or abdominal CT. Subsequent management, including additional imaging, was at the discretion of the physician. We compared the three groups with respect to the 30-day incidence of high-risk diagnoses with complications that could be related to missed or delayed diagnosis and the 6-month cumulative radiation exposure. Secondary outcomes were serious adverse events, related serious adverse events (deemed attributable to study participation), pain (assessed on an 11-point visual-analogue scale, with higher scores indicating more severe pain), return emergency department visits, hospitalizations, and diagnostic accuracy. A total of 2759 patients underwent randomization: 908 to point-of-care ultrasonography, 893 to radiology ultrasonography, and 958 to CT. The incidence of high-risk diagnoses with complications in the first 30 days was low (0.4%) and did not vary according to imaging method. The mean 6-month cumulative radiation exposure was significantly lower in the ultrasonography groups than in the CT group (P<0.001). Serious adverse events occurred in 12.4% of the patients assigned to point-of-care ultrasonography, 10.8% of those assigned to radiology ultrasonography, and 11.2% of those assigned to CT (P=0.50). Related adverse events were infrequent (incidence, 0.4%) and similar across groups. By 7 days, the average pain score was 2.0 in each group (P=0.84). Return emergency department visits, hospitalizations, and diagnostic accuracy did not differ significantly among the groups. Initial ultrasonography was associated with lower cumulative radiation exposure than initial CT, without significant differences in high-risk diagnoses with complications, serious adverse events, pain scores, return emergency department visits, or hospitalizations. (Funded by the Agency for Healthcare Research and Quality.).

  7. Comparing Magnetic Resonance Imaging and High-Resolution Dynamic Ultrasonography for Diagnosis of Plantar Plate Pathology: A Case Series.

    PubMed

    Donegan, Ryan J; Stauffer, Anthony; Heaslet, Michael; Poliskie, Michael

    Plantar plate pathology has gained noticeable attention in recent years as an etiology of lesser metatarsophalangeal joint pain. The heightened clinical awareness has led to the need for more effective diagnostic imaging accuracy. Numerous reports have established the accuracy of both magnetic resonance imaging and ultrasonography for the diagnosis of plantar plate pathology. However, no conclusions have been made regarding which is the superior imaging modality. The present study reports a case series directly comparing high-resolution dynamic ultrasonography and magnetic resonance imaging. A multicenter retrospective comparison of magnetic resonance imaging versus high-resolution dynamic ultrasonography to evaluate plantar plate pathology with surgical confirmation was conducted. The sensitivity, specificity, and positive and negative predictive values for magnetic resonance imaging were 60%, 100%, 100%, and 33%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 66%. The sensitivity, specificity, and positive and negative predictive values for high-resolution dynamic ultrasound imaging were 100%, 100%, 100%, and 100%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 100%. The p value using Fisher's exact test for magnetic resonance imaging and high-resolution dynamic ultrasonography was p = .45, a difference that was not statistically significant. High-resolution dynamic ultrasonography had greater accuracy than magnetic resonance imaging in diagnosing lesser metatarsophalangeal joint plantar plate pathology, although the difference was not statistically significant. The present case series suggests that high-resolution dynamic ultrasonography can be considered an equally accurate imaging modality for plantar plate pathology at a potential cost savings compared with magnetic resonance imaging. Therefore, high-resolution dynamic ultrasonography warrants further investigation in a prospective study. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. ROLE OF IMAGING TESTS FOR PREOPERATIVE LOCATION OF PATHOLOGIC PARATHYROID TISSUE IN PATIENTS WITH PRIMARY HYPERPARATHYROIDISM.

    PubMed

    Coelho, Maria Caroline Alves; de Oliveira E Silva de Morais, Nathalie Anne; Beuren, Andrea Cristiani; Lopes, Cristiane Bertolino; Santos, Camila Vicente; Cantoni, Joyce; Neto, Leonardo Vieira; Lima, Maurício Barbosa

    2016-09-01

    Primary hyperparathyroidism (PHPT) can be cured by parathyroidectomy, and the preoperative location of enlarged pathologic parathyroid glands is determined by imaging studies, especially cervical ultrasonography and scintigraphy scanning. The aim of this retrospective study was to evaluate the use of preoperative cervical ultrasonography and/or parathyroid scintigraphy in locating pathologic parathyroid tissue in a group of patients with PHPT followed in the same endocrine center. We examined the records of 61 patients who had undergone parathyroidectomy for PHPT following (99m)Tc-sestamibi scintigraphy scan and/or cervical ultrasonography. Scintigraphic and ultrasonographic findings were compared to histopathologic results of the surgical specimens. Ultrasonography detected enlarged parathyroid glands in 87% (48/55) of patients with PHPT and (99m)Tc-sestamibi scintigraphy in 79% (37/47) of the cases. Ultrasonography was able to correctly predict the surgical findings in 75% (41/55) of patients and scintigraphy in 72% (34/47). Of 7 patients who had negative ultrasonography, scintigraphy correctly predicted the surgical results in 2 (29%). Of 10 patients who had negative scintigraphy, ultrasonography correctly predicted the surgical results in 4 (40%). When we analyzed only patients with solitary eutopic parathyroid adenomas, the predictive positive values of ultrasonography and scintigraphy were 90% and 86%, respectively. Cervical ultrasonography had a higher likelihood of a correct positive test and a greater predictive positive value for solitary adenoma compared to (99m)Tc-sestamibi and should be used as the first diagnostic tool for preoperative localization of affected parathyroid glands in PHPT. Ca = calcium IEDE = Instituto Estadual de Diabetes e Endocrinologia Luiz Capriglione PHPT = primary hyperparathyroidism PTH = parathyroid hormone.

  9. Preoperative Duplex Scanning is a Helpful Diagnostic Tool in Neurogenic Thoracic Outlet Syndrome.

    PubMed

    Orlando, Megan S; Likes, Kendall C; Mirza, Serene; Cao, Yue; Cohen, Anne; Lum, Ying Wei; Freischlag, Julie A

    2016-01-01

    To evaluate the diagnostic role of venous and arterial duplex scanning in neurogenic thoracic outlet syndrome (NTOS). Retrospective review of patients who underwent duplex ultrasonography prior to first rib resection and scalenectomy (FRRS) for NTOS from 2005 to 2013. Abnormal scans included ipsilateral compression (IC) with abduction of the symptomatic extremity (>50% change in subclavian vessel flow), contralateral (asymptomatic side) compression (CC) or bilateral compression (BC). A total of 143 patients (76% female, average age 34, range 13-59) underwent bilateral preoperative duplex scanning. Ipsilateral compression was seen in 44 (31%), CC in 12 (8%), and BC in 14 (10%). Seventy-three (51%) patients demonstrated no compression. Patients with IC more often experienced intraoperative pneumothoraces (49% vs. 25%, P < .05) and had positive Adson tests (86% vs. 61%, P < .02). Compression of the subclavian vein or artery on duplex ultrasonography can assist in NTOS diagnosis. Ipsilateral compression on abduction often correlates with Adson testing. © The Author(s) 2016.

  10. [Abdominal ultrasonography in patients with diabetes mellitus. Part 1: Liver].

    PubMed

    Jenssen, C; Pietsch, C; Gottschalk, U; Barreiros, A P; Teufel, A; Cui, X W; Dietrich, C F

    2015-04-01

    In patients with diabetes mellitus, abdominal ultrasonography is the appropriate diagnostic technique to detect and to follow-up secondary and accompanying diseases of the liver, the kidneys, the pancreas, the gastrointestinal tract and of abdominal vessels. Moreover, pancreatic and hepatic diseases may be realized which are of etiological importance for diabetes mellitus. Based on a systematic survey of the published literature, this review in 3 parts will describe the value of abdominal ultrasonography in patients with diabetes mellitus. Part 1 deals with the diagnostic relevance and particular findings of ultrasonographic methods in hepatic manifestations and complications of diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Acute primary mesenteroaxial gastric volvulus in a 6 years old child; the contribution of ultrasonographic findings to the prompt diagnosis (a case report and review of the literature).

    PubMed

    Patoulias, Dimitrios; Rafailidis, Vasileios; Kalogirou, Maria; Farmakis, Konstantinos; Rafailidis, Dimitrios; Patoulias, Ioannis

    2017-01-01

    The aim of the present case study is to raise concern on the proper diagnostic approach of acute gastric volvulus (AGV) cases, in which, the key issue is the timely diagnosis and the prompt therapeutic intervention. After thorough and systematic research of the current literature, it is concluded that early diagnosis remains challenging, while there is no relevant publication with emphasis on the contribution of ultrasonography to the diagnostic documentation of AGV. A 6 years old boy was admitted to our Department due to repeatedly non bilious vomiting and food refusal during the last 72 hours before admission. Physical examination revealed the presence of a spherical, painful mass in the epigastrium, which did not recede a er placement of a nasogastric tube. Abdominal radiography showed the presence of a large gastric air bubble. Ultrasonography highlighted a distended and fluid-filled stomach, which was displaced in a cephalic position compared to esophagus and a pylorus pointing downward, in a cranial caudal orientation. Following barium meal examination confirmed the diagnosis of gastric volvulus. Patient underwent an urgent exploratory laparotomy, revealing the presence of acute mesenteroaxial gastric volvulus with a serosal ecchymosis in the major arc. After restoration of the gastric volvulus, thorough intraoperative investigation on the existence of a subject cause followed. Presence of relaxation of stomach's ligaments was finally documented. Fixation of the stomach' fundus to the diaphragm and anterior gastropexy were then conducted. Postoperative period was uneventful and the patient was discharged home on the 4th postoperative day. In conclusion, we believe that ultrasonography plays a significant role in the diagnostic approach of acute gastric volvulus, as it has the potential to detect findings suggestive of the diagnosis. Once the diagnosis is suspected on ultrasonography, contrast series should be performed, without further delay, in order to con rm the diagnosis.

  12. Meridional lenticular astigmatism associated with bilateral concurrent uveal metastases in renal cell carcinoma.

    PubMed

    Priluck, Joshua C; Grover, Sandeep; Chalam, Kv

    2012-01-01

    To demonstrate a case illustrating meridional lenticular astigmatism as a result of renal cell carcinoma uveal metastases. Case report with images. Clinical findings and diagnostic testing of a patient with acquired meridional lenticular astigmatism are described. The refraction revealed best-corrected visual acuity of 20/20-1 OD (-2.50 + 0.25 × 090) and 20/50 OS (-8.25 + 3.25 × 075). Bilateral concurrent renal cell carcinoma metastases to the choroid and ciliary body are demonstrated by utilizing ultrasonography, ultrawidefield fluorescein angiography, and unique spectral-domain optical coherence tomography. Metastatic disease should be included in the differential of acquired astigmatism. Spectral-domain optical coherence tomography, ultrawidefield fluorescein angiography, and ultrasonography have roles in delineating choroidal metastases.

  13. Ultrasonography in gastroenterology.

    PubMed

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  14. Ultrasonography of the hand, wrist, and elbow.

    PubMed

    Bodor, Marko; Fullerton, Brad

    2010-08-01

    High-frequency diagnostic ultrasonography of the hand, wrist and elbow has significant potential to improve the quality of diagnosis and care provided by neuromuscular and musculoskeletal specialists. In patients referred for weakness, pain and numbness of the hand, wrist or elbow, diagnostic ultrasonography can be an adjunct to electrodiagnosis and help in identifying ruptured tendons and treating conditions such as carpal tunnel syndrome or trigger finger. Use of a small high-frequency (>10-15 MHz) transducer, an instrument with a blunt pointed tip to enhance sonopalpation and a model of the hand, wrist and elbow is advised to enhance visualization of small anatomical structures and complex bony contours. A range of conditions, including tendon and ligament ruptures, trigger finger, de Quervain tenosynovitis, intersection syndrome, lateral epicondylitis, and osteoarthritis, is described along with detailed ultrasonography-guided injection techniques for carpal tunnel syndrome and trigger finger. Copyright 2010 Elsevier Inc. All rights reserved.

  15. High-frequency ultrasonography (HFUS) as a useful tool in differentiating between plaque morphea and extragenital lichen sclerosus lesions

    PubMed Central

    Reszke, Radomir; Szepietowski, Jacek C.

    2017-01-01

    Introduction Morphea and lichen sclerosus (LS) are chronic inflammatory diseases that may pose a diagnostic challenge for a physician. High-frequency ultrasonography (HFUS) is a versatile diagnostic method utilized in dermatologic practice, allowing monitoring the course of the disease, treatment response and differentiation between certain skin disorders. Aim To prove the usefulness of HFUS in differentiating between plaque morphea and extragenital LS lesions. Material and methods We examined 16 patients with plaque morphea and 4 patients with extragenital LS using 20 MHz taberna pro medicum TM (Germany) device. Results Investigations revealed hyperechogenic entrance echo in both morphea and LS lesions, whereas a distinct polycyclic surface of the entrance echo was detected exclusively in LS. Conclusions High-frequency ultrasonography is a current diagnostic modality that may prove useful in differentiating between morphea and LS lesions. PMID:29507565

  16. [The role of ultrasonography exam in orbital-ocular tumors].

    PubMed

    Ciocâlteu, Alina Mihaela; Ardeleanu, S; Checheriţă, I A

    2011-01-01

    Ophthalmology is one of the specialties that have particularly benefited from the contribution of ultrasonography exam as a method of investigation. Ultrasonography is very much essential for diagnostic to complement other clinical and laboratory investigations, providing images in real time. The basic principle of diagnostic ultrasound is to study and to interpret the changes they undergo when crossing ultrasonic waves diverse biological properties different sound, and such injuries can be traced in the dynamics or can be documented on photographic paper and thus can diagnose correct certain eye diseases. The indications for performing ultrasound consist in: measurement of distances and volumes, examine difficult or inaccessible case of opaque media; ophthalmoscopic view of a mass lesion, examine the orbit or optic nerve. The advantages of ultrasound for orbital-ocular tumors are represented by the fact that ultrasound is a noninvasive method, safe, well tolerated, less expensive that the advantage of determining the position and distance from structures ocular tumor. High frequency ultrasound provides excellent resolution of 0-1 to 0.01 mm, and serial scans allow tracking progress and measuring lesion diameters tumor while allowing monitoring and evaluation of stereotactic radiation treatments applied to small tumors. In conclusion ultrasound allows not only early diagnosis of eye tumors, but accurate assessment of the proposed therapy and of the evolution of detected mass lesions or tumors.

  17. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    PubMed

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  18. Meridional lenticular astigmatism associated with bilateral concurrent uveal metastases in renal cell carcinoma

    PubMed Central

    Priluck, Joshua C; Grover, Sandeep; Chalam, KV

    2012-01-01

    Purpose To demonstrate a case illustrating meridional lenticular astigmatism as a result of renal cell carcinoma uveal metastases. Methods Case report with images. Results Clinical findings and diagnostic testing of a patient with acquired meridional lenticular astigmatism are described. The refraction revealed best-corrected visual acuity of 20/20–1 OD (−2.50 + 0.25 × 090) and 20/50 OS (−8.25 + 3.25 × 075). Bilateral concurrent renal cell carcinoma metastases to the choroid and ciliary body are demonstrated by utilizing ultrasonography, ultrawidefield fluorescein angiography, and unique spectral-domain optical coherence tomography. Conclusions Metastatic disease should be included in the differential of acquired astigmatism. Spectral-domain optical coherence tomography, ultrawidefield fluorescein angiography, and ultrasonography have roles in delineating choroidal metastases. PMID:23152663

  19. Clinical use of ultrasonography associated with color Doppler in the diagnosis and follow-up of acute pyelonephritis.

    PubMed

    Dell'Atti, Lucio; Borea, Pier Andrea; Ughi, Gianni; Russo, Gian Rosario

    2010-12-01

    The purpose of this study is to evaluate the current role of the Ultrasound associated with the color-Doppler in the diagnosis of acute pyelonephritis (APN) and to compare ultrasound images with CT images in order to reduce the amount radiation absorbe without significant loss of diagnostic efficacy, since this disease in most cases affects young adults. We studied 38 patients (aged 17-65 years) who presented from September 2007 to March 2010 to the emergency department with suspected diagnosis of APN. All patients underwent first to an ultrasound study, then to abdominal CT. Renal, perirenal and extrarenal tomographic findings usually associated with acute pyelonephritis were analyzed, in an attempt to identify what are the differences with respect to the images obtained with an ultrasound study. All patients then performed ultrasonography and/or abdominal CT evaluation one month later, 25 patients repeated both examinations, while the other 13 repeated only ultrasound. In 38 subjects with suspected APN, CT assessed the presence in 79% and in 21% the absence of the disease. Ultrasonography in 68% of cases diagnosed APN, by an increase in kidney size related to the presence of hypoechoic areas associated to edema, blurred margins and reduction of the color-Doppler vascularity. Ultrasound associated with the use of color-Doppler revealed a sensibility of 76% and specificity of 75%. Color and power-Doppler have better diagnostic accuracy than basic gray scale ultrasound, in the diagnosis of focal pyelonephritis. Therefore the combined use of ultrasound and color-Doppler can obtain useful information about the diagnosis and follow-up of the disease, with an improvement in terms of cost, without significantly altering the diagnostic efficacy and reducing the amount of radiation absorbed.

  20. Comparison of the use of scapular ultrasonography, physical examination, and measurement of serum biomarkers of bone turnover versus scintigraphy for detection of bone fragility syndrome in horses.

    PubMed

    Arens, Amanda M; Puchalski, Sarah M; Whitcomb, Mary Beth; Bell, Robin; Gardner, Ian A; Stover, Susan M

    2013-01-01

    To define scintigraphic, physical examination, and scapular ultrasonographic findings consistent with bone fragility syndrome (BFS) in horses; develop indices of BFS severity; and assess accuracy of physical examination, scapular ultrasonography, and serum biomarkers for BFS diagnosis. Prospective case-control study. 48 horses (20 horses with BFS and 28 control horses). Horses underwent forelimb scintigraphic evaluation, physical examination, scapular ultrasonography, and serum collection. Scintigraphy was used as a reference standard to which physical examination, scapular ultrasonography, and concentrations of serum biomarkers (carboxy-terminal telopeptide of collagen crosslinks and bone-specific alkaline phosphatase activity) were compared for assessing accuracy in BFS diagnosis. A diagnosis of BFS was strongly supported on scintigraphy by ≥ 2 regions of increased radiopharmaceutical uptake, including 1 region in the scapular spine and 1 region in the scapular body or ribs; on physical examination by lateral bowing of the scapulae; and on ultrasonography by widening of the scapular spine. None of the tests evaluated were accurate enough to replace scintigraphy for mild disease; however, physical examination and scapular ultrasonography were accurate in horses with moderate to severe BFS. Serum biomarkers were not accurate for BFS diagnosis. Scintigraphy remained the most informative diagnostic modality for BFS, providing insight into disease severity and distribution; however, physical examination and scapular ultrasonographic abnormalities were diagnostic in horses with moderate to severe disease. Proposed severity indices classified the spectrum of disease manifestations. Clearly defined criteria for interpretation of diagnostic tests aid in the detection of BFS. Severity indices may be useful for assessing disease progression and response to treatment.

  1. Doppler ultrasonography in living donor liver transplantation recipients: Intra- and post-operative vascular complications

    PubMed Central

    Abdelaziz, Omar; Attia, Hussein

    2016-01-01

    Living-donor liver transplantation has provided a solution to the severe lack of cadaver grafts for the replacement of liver afflicted with end-stage cirrhosis, fulminant disease, or inborn errors of metabolism. Vascular complications remain the most serious complications and a common cause for graft failure after hepatic transplantation. Doppler ultrasound remains the primary radiological imaging modality for the diagnosis of such complications. This article presents a brief review of intra- and post-operative living donor liver transplantation anatomy and a synopsis of the role of ultrasonography and color Doppler in evaluating the graft vascular haemodynamics both during surgery and post-operatively in accurately defining the early vascular complications. Intra-operative ultrasonography of the liver graft provides the surgeon with useful real-time diagnostic and staging information that may result in an alteration in the planned surgical approach and corrections of surgical complications during the procedure of vascular anastomoses. The relevant intra-operative anatomy and the spectrum of normal and abnormal findings are described. Ultrasonography and color Doppler also provides the clinicians and surgeons early post-operative potential developmental complications that may occur during hospital stay. Early detection and thus early problem solving can make the difference between graft survival and failure. PMID:27468207

  2. Two-dimensional ultrasonography of the brain: its diagnostic usefullness in herpes simplex encephalitis and cytomegalic inclusion disease.

    PubMed

    Matsumoto, N; Yano, S; Miyao, M; Kamoshita, S; Itoh, K

    1983-01-01

    We have used brain ultrasonography in diagnosing and following up two infants, one with herpes simplex encephalitis and the other with cytomegalic inclusion disease. It was found that this technique was very useful to observe the changes of the brain parenchyma such as cystic degeneration and periventricular calcification. Also because it is non-invasive and an easy procedure, ultrasonography can be applied even for infants in critical condition when needed.

  3. Comparison of ultrasonography and physical examination in the diagnosis of incisional hernia in a prospective study.

    PubMed

    Bloemen, A; van Dooren, P; Huizinga, B F; Hoofwijk, A G M

    2012-02-01

    Incisional hernia is a frequent complication of abdominal surgery (incidence 2-20%). Diagnosis by physical examination is sometimes difficult, especially in small incisional hernias or in obese patients. The additional diagnostic value of standardized ultrasonography was evaluated in this prospective study. A total of 456 patients participating in a randomized trial comparing two suture materials for closure of the abdominal fascia underwent physical examination and ultrasonography at 6-month intervals. Wound complaints and treatment of incisional hernia were also noted. Statistical analysis was performed using the Chi-squared and Fisher's exact tests (SPSS). Interest variability analysis was performed. During a median follow-up of 31 months, 103 incisional hernias were found. A total of 82 incisional hernias were found by physical examination and an additional 21 with ultrasonography. Six of these additional hernias were symptomatic and only one of the additional hernias received operative treatment. The false-negative rates for physical examination and ultrasonography were 25.3 and 24.4%, respectively. Interest variability was low, with a Kappa of 0.697 (P < 0.001). There are no clear diagnostic criteria for incisional hernia available in the literature. Standardized combination of ultrasonography with physical examination during follow-up yields a significant number of, mostly asymptomatic, hernias, which would not be found using physical examination alone. This is especially relevant in research settings.

  4. Diagnostic Accuracy of Ultrasonography and Radiography in Initial Evaluation of Chest Trauma Patients.

    PubMed

    Vafaei, Ali; Hatamabadi, Hamid Reza; Heidary, Kamran; Alimohammadi, Hosein; Tarbiyat, Mohammad

    2016-01-01

    Application of chest radiography for all multiple trauma patients is associated with a significant increase in total costs, exposure to radiation, and overcrowding of the emergency department. Ultrasound has been introduced as an alternative diagnostic tool in this regard. The aim of the present study is to compare the diagnostic accuracy of chest ultrasonography and radiography in detection of traumatic intrathoracic injuries. In the present prospective cross-sectional study, patients with traumatic intrathoracic injuries, who were referred to the emergency department from December 2013 to December 2014, were assessed. The patients underwent bedside ultrasound, radiographic and computed tomography (CT) scan examinations based on ATLS recommendations. Screening performance characteristics of ultrasonography and radiography were compared using SPSS 21.0. Chest CT scan was considered as gold standard. 152 chest trauma patients with a mean age of 31.4 ± 13.8 years (range: 4 ‒ 67), were enrolled (77.6% male). Chest CT scan showed pulmonary contusion in 48 (31.6%) patients, hemothorax in 29 (19.1%), and pneumothorax in 55 (36.2%) cases. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion were 0.91 (95% CI: 0.86‒0.96), 0.86 (95% CI: 0.78‒0.94), and 0.80 (95% CI: 0.736‒0.88), respectively. Area under the ROC curve of radiography was 0.80 (95% CI: 0.736‒0.87) for detection of pneumothorax, 0.77 (95% CI: 0.68‒0.86) for hemothorax, and 0.58 (95% CI: 0.5‒0.67) for pulmonary contusion. Comparison of areas under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax (p = 0.02) and pulmonary contusion (p < 0.001). However, the diagnostic value of the two tests was equal in detection of hemothorax (p = 0.08). The results of the present study showed that ultrasonography is preferable to radiography in the initial evaluation of patients with traumatic injuries to the thoracic cavity.

  5. Ultrasonography of ovarian hyperandrogenemia

    NASA Astrophysics Data System (ADS)

    Kuzmina, Svetlana A.; Zharkin, Nikolay A.

    2001-05-01

    The method of ultrasonography is high informative and widely used in diagnostics of ovarian hyperandrogenaemia. The majority of authors consider that a hyperplasia of a stroma is the main pathognomonic marker of polycystic ovaries (PCO). Still recently swell of a stroma was valued visually, that had subjective nature. We offer for the first time a way of diagnostics of stromal hyperplasia grounded on measurement of a volume of a stroma and ovary with ultrasound method, calculation of the ratio of a volume of the ovary to a volume of a stroma for every patient.

  6. Role of ultrasonography with color-Doppler in the emergency diagnosis of acute penile fracture: a case report.

    PubMed

    Buyukkaya, Ramazan; Buyukkaya, Ayla; Ozturk, Beyhan; Kayıkçı, Ali; Yazgan, Ömer

    2014-03-01

    Penile fracture is the rupture of tunica albuginea, typically resulting from blunt trauma, intercourse, or penile manipulation. Diagnosis is made clinically. Ultrasound is not used frequently in diagnosis of penile fracture but it provides a fast, non-invasive alternative to more often used MRI and cavernography. We aimed to present diagnostic ultrasound and color Doppler images of a patient with acute penile fracture in conjunction with literature.

  7. Shear-wave elastography in breast ultrasonography: the state of the art

    PubMed Central

    2017-01-01

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy. PMID:28513127

  8. Role of ultrasound in colorectal diseases.

    PubMed

    Bor, Renáta; Fábián, Anna; Szepes, Zoltán

    2016-11-21

    Ultrasound is an undervalued non-invasive examination in the diagnosis of colonic diseases. It has been replaced by the considerably more expensive magnetic resonance imaging and computed tomography, despite the fact that, as first examination, it can usefully supplement the diagnostic process. Transabdominal ultrasound can provide quick information about bowel status and help in the choice of adequate further examinations and treatment. Ultrasonography, as a screening imaging modality in asymptomatic patients can identify several colonic diseases such as diverticulosis, inflammatory bowel disease or cancer. In addition, it is widely available, cheap, non-invasive technique without the use of ionizing radiation, therefore it is safe to use in childhood or during pregnancy, and can be repeated at any time. New ultrasound techniques such as elastography, contrast enhanced and Doppler ultrasound, mini-probes rectal and transperineal ultrasonography have broadened the indication. It gives an overview of the methodology of various ultrasound examinations, presents the morphology of normal bowel wall and the typical changes in different colonic diseases. We will pay particular attention to rectal and transperineal ultrasound because of their outstanding significance in the diagnosis of rectal and perineal disorders. This article seeks to overview the diagnostic impact and correct indications of bowel ultrasound.

  9. Diagnostic imaging features of normal anal sacs in dogs and cats.

    PubMed

    Jung, Yechan; Jeong, Eunseok; Park, Sangjun; Jeong, Jimo; Choi, Ul Soo; Kim, Min-Su; Kim, Namsoo; Lee, Kichang

    2016-09-30

    This study was conducted to provide normal reference features for canine and feline anal sacs using ultrasound, low-field magnetic resonance imaging (MRI) and radiograph contrast as diagnostic imaging tools. A total of ten clinically normal beagle dogs and eight clinically normally cats were included. General radiography with contrast, ultrasonography and low-field MRI scans were performed. The visualization of anal sacs, which are located at distinct sites in dogs and cats, is possible with a contrast study on radiography. Most surfaces of the anal sacs tissue, occasionally appearing as a hyperechoic thin line, were surrounded by the hypoechoic external sphincter muscle on ultrasonography. The normal anal sac contents of dogs and cats had variable echogenicity. Signals of anal sac contents on low-field MRI varied in cats and dogs, and contrast medium using T1-weighted images enhanced the anal sac walls more obviously than that on ultrasonography. In conclusion, this study provides the normal features of anal sacs from dogs and cats on diagnostic imaging. Further studies including anal sac evaluation are expected to investigate disease conditions.

  10. Diagnostic imaging features of normal anal sacs in dogs and cats

    PubMed Central

    Jung, Yechan; Jeong, Eunseok; Park, Sangjun; Jeong, Jimo; Choi, Ul Soo; Kim, Min-Su; Kim, Namsoo

    2016-01-01

    This study was conducted to provide normal reference features for canine and feline anal sacs using ultrasound, low-field magnetic resonance imaging (MRI) and radiograph contrast as diagnostic imaging tools. A total of ten clinically normal beagle dogs and eight clinically normally cats were included. General radiography with contrast, ultrasonography and low-field MRI scans were performed. The visualization of anal sacs, which are located at distinct sites in dogs and cats, is possible with a contrast study on radiography. Most surfaces of the anal sacs tissue, occasionally appearing as a hyperechoic thin line, were surrounded by the hypoechoic external sphincter muscle on ultrasonography. The normal anal sac contents of dogs and cats had variable echogenicity. Signals of anal sac contents on low-field MRI varied in cats and dogs, and contrast medium using T1-weighted images enhanced the anal sac walls more obviously than that on ultrasonography. In conclusion, this study provides the normal features of anal sacs from dogs and cats on diagnostic imaging. Further studies including anal sac evaluation are expected to investigate disease conditions. PMID:26645338

  11. Use of dynamic 3-dimensional transvaginal and transrectal ultrasonography to assess posterior pelvic floor dysfunction related to obstructed defecation.

    PubMed

    Murad-Regadas, Sthela M; Regadas Filho, Francisco Sergio Pinheiro; Regadas, Francisco Sergio Pinheiro; Rodrigues, Lusmar Veras; de J R Pereira, Jacyara; da S Fernandes, Graziela Olivia; Dealcanfreitas, Iris Daiana; Mendonca Filho, Jose Jader

    2014-02-01

    New ultrasound techniques may complement current diagnostic tools, and combined techniques may help to overcome the limitations of individual techniques for the diagnosis of anorectal dysfunction. A high degree of agreement has been demonstrated between echodefecography (dynamic 3-dimensional anorectal ultrasonography) and conventional defecography. Our aim was to evaluate the ability of a combined approach consisting of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a 3-dimensional biplane endoprobe to assess posterior pelvic floor dysfunctions related to obstructed defecation syndrome in comparison with echodefecography. This was a prospective, observational cohort study conducted at a tertiary-care hospital. Consecutive female patients with symptoms of obstructed defecation were eligible. Each patient underwent assessment of posterior pelvic floor dysfunctions with a combination of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a biplane transducer and with echodefecography. Kappa (κ) was calculated as an index of agreement between the techniques. Diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of the combined technique in detection of posterior dysfunctions was assessed with echodefecography as the standard for comparison. A total of 33 women were evaluated. Substantial agreement was observed regarding normal relaxation and anismus. In detecting the absence or presence of rectocele, the 2 methods agreed in all cases. Near-perfect agreement was found for rectocele grade I, grade II, and grade III. Perfect agreement was found for entero/sigmoidocele, with near-perfect agreement for rectal intussusception. Using echodefecography as the standard for comparison, we found high diagnostic accuracy of transvaginal and transrectal ultrasonography in the detection of posterior dysfunctions. This combined technique should be compared with other dynamic techniques and validated with conventional defecography. Dynamic 3-dimensional transvaginal and transrectal ultrasonography is a simple and fast ultrasound technique that shows strong agreement with echodefecography and may be used as an alternative method to assess patients with obstructed defecation syndrome.

  12. [Ultrasonography of the lower urethra in male sheep lambs].

    PubMed

    AlLugami, Ammar; von Pückler, Kerstin; Sickinger, Marlene

    2018-06-01

    In male small ruminants, voiding disturbances are not uncommon. A precise knowledge of the underlying disease is essential for prognostic evaluation as well as for a decision concerning the therapeutic approach. Common reasons for voiding disturbances in the male small ruminant are obstructive urolithiasis, traumata of the penis or inflammatory processes within the urethra or urinary bladder. The diagnostic method of choice - in addition to clinical examination - is diagnostic imaging. Because radiology is not always possible under field conditions, the aim of this article is a detailed presentation of ultrasonography of the distal urethra of the male lamb. Schattauer GmbH.

  13. [Analysis of eye ultrasonography in patients with trinitrotoluene cataract].

    PubMed

    Huang, Dongmei; Zhu, Linping; Yang, Jinping; Wu, Donping

    2015-04-01

    To evaluate the diagnostic value of ultrasonography for trinitrotoluene (TNT) cataract. The morphology and internal echoes of 90 lenses of 45 TNT cataract patients and 120 lenses of 60 healthy adults were observed and compared using ultrasonography and slit lamp, and the hemodynamic parameters of the post-ophthalmic artery were also measured. The findings of the slit-lamp microscope were regarded as diagnostic criteria, and the sensitivity, specificity, and accordance rate of ultrasonography in the diagnosis of TNT cataract were calculated. The sensitivity, specificity, and accordance rate of ultrasonography in the diagnosis of TNT cataract were 93.33%, 100.00%, and 97.14%, respectively; the positive and negative predictive values were 100% and 95.23%, respectively; the positive and negative likelihood ratios were 93.33 and 0.67, especuvey. With the progression TNT cataract, utrasonography showed that the lenses demonstrated morphological changes (spindle-shaped, spherical, and discoid morphologies), and the arc echoes of the posterior capsule were thickened and enhanced. The TNT cataract patients showed significantly lower peak systolic velocity and end-diastolic velocity of the ophthalmic artery (OA) and central retinal artery (P<0.01) and a significantly higher resistance index (P<0.05) than the healthy adults. The sensitivity of ultrasonography in the diagnosis of TNT cataract is similar to that of slit lamp. Ultrasonography can demonstrate objectively the shape, range, and degree of lens opacity in an efficient manner, which is conducive to the diagnosis and staging of TNT cataract by slit lamp, and can also provide hemodynamic information of the OA, thus providing new ideas for clinical physicians in evaluating the disease and clinical efficacy as well as exploring therapies.

  14. Chest ultrasonography for the emergency diagnosis of traumatic pneumothorax and haemothorax: A systematic review and meta-analysis.

    PubMed

    Staub, Leonardo Jönck; Biscaro, Roberta Rodolfo Mazzali; Kaszubowski, Erikson; Maurici, Rosemeri

    2018-03-01

    To assess the accuracy of the chest ultrasonography for the emergency diagnosis of traumatic pneumothorax and haemothorax in adults. Systematic review and meta-analysis. PubMed, EMBASE, Scopus, Web of Science and LILACS (up to 2016) were systematically searched for prospective studies on the diagnostic accuracy of ultrasonography for pneumothorax and haemothorax in adult trauma patients. The references of other systematic reviews and the included studies were checked for further articles. The characteristics and results of the studies were extracted using a standardised form, and their methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Primary analysis was performed considering each hemithorax as an independent unit, while secondary analysis considered each patient. The global diagnostic accuracy of the chest ultrasonography was estimated using the Rutter-Gatsonis hierarchical summary ROC method. Moreover, Reitsma's bivariate model was used to estimate the sensitivity, specificity, positive likelihood ratio (LR + ) and negative likelihood ratio (LR-) of each sonographic sign. This review was previously registered (PROSPERO CRD42016048085). Nineteen studies were included in the review, 17 assessing pneumothorax and 5 assessing haemothorax. The reference standard was always chest tomography, alone or in parallel with chest radiography and observation of the chest tube. The overall methodological quality of the studies was low. The diagnostic accuracy of chest ultrasonography had an area under the curve (AUC) of 0.979 for pneumothorax (Fig). The absence of lung sliding and comet-tail artefacts was the most reported sonographic sign of pneumothorax, with a sensitivity of 0.81 (95% confidence interval [95%CI], 0.71-0.88), specificity of 0.98 (95%CI, 0.97-0.99), LR+ of 67.9 (95%CI, 26.3-148) and LR- of 0.18 (95%CI, 0.11-0.29). An echo-poor or anechoic area in the pleural space was the only sonographic sign for haemothorax, with a sensitivity of 0.60 (95%CI, 0.31-0.86), specificity of 0.98 (95%CI, 0.94-0.99), LR+ of 37.5 (95%CI, 5.26-207.5), LR- of 0.40 (95%CI, 0.17-0.72) and AUC of 0.953. Notwithstanding the limitations of the included studies, this systematic review and meta-analysis suggested that chest ultrasonography is an accurate tool for the diagnostic assessment of traumatic pneumothorax and haemothorax in adults. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    PubMed

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of meniscal pathology was associated with Sn = 91.7%, Sp = 66.7%, PPV = 84.6%, NPV = 80.0%, CCR = 81.1%, LR(+) = 2.75, and LR(-) = 0.13. Ultrasonography was two times more likely than MRI to correctly determine presence or absence of meniscal pathology seen arthroscopically in this study. Ultrasonography is a useful tool for diagnosis of meniscal pathology with potential advantages over MRI. Based on these data and available portable equipment, ultrasonography could be considered for use as a point-of-injury diagnostic modality for meniscal injuries. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. The role of radiology in diagnosis and management of drug mules: an update with new challenges and new diagnostic tools

    PubMed Central

    Cengel, Ferhat

    2016-01-01

    Emergency physicians and radiologists have been increasingly encountering internal concealment of illegal drugs. The packages commonly contain powdered solid drugs such as cocaine, heroin, methamphetamine and hashish, but they may also contain cocaine in the liquid form. The second type of package has recently been more commonly encountered, and poses a greater diagnostic challenge. As clinical evaluation and laboratory tests frequently fail to make the correct diagnosis, imaging examination is typically required. Imaging methods assume a vital role in the diagnosis, follow-up and management. Abdominal X-ray, ultrasonography, CT and MRI are used for the imaging purposes. Among the aforementioned methods, low-dose CT is state-of-the-art in these cases. It is of paramount importance that radiologists have a full knowledge of the imaging characteristics of these packages and accurately guide physicians and security officials. PMID:26867003

  17. Indices of diagnostic abdominal ultrasonography in acute appendicitis: influence of gender and physical constitution, time evolution of the disease and experience of radiologist.

    PubMed

    Peixoto, Rodrigo de Oliveira; Nunes, Tarcizo Afonso; Gomes, Carlos Augusto

    2011-01-01

    To assess the value of abdominal ultrasonography in the diagnosis of acute appendicitis and the influence of gender, physical constitution, experience of the radiologist and the time evolution of the disease on the results of diagnostic indices. We prospectively evaluated 156 patients with clinical diagnosis of acute appendicitis who underwent laparoscopic appendectomy and abdominal ultrasonography, together with pathology of the excised appendices. Patients were allocated in relation to BMI in both groups (below or above 25 kg/m²) and radiologists, in three groups according to their professional experience (less than five years, between five and 10 years and more than 10 years). The survey also assessed the influence of gender and time of disease progression using the median of 36 hours. The sensitivity and specificity of abdominal ultrasonography for diagnosing appendicitis were 64.9 and 72% respectively. Gender, body mass index, length of experience of the radiologists in the three groups and time of onset of symptoms showed no significant differences in the establishment of sonographic diagnosis of acute appendicitis. The abdominal ultrasonography showed low sensitivity and specificity and little contribution to the diagnosis of acute appendicitis. Gender, physical constitution, the experience of the radiologist and time of onset of symptoms did not affect the outcome of the sonography.

  18. Image-guided fine-needle aspiration of retroperitoneal masses: The role of the cytopathologist.

    PubMed

    Mehdi, Ghazala; Maheshwari, Veena; Afzal, Sheerin; Ansari, Hena A; Ahmad, Ibne

    2013-01-01

    Retroperitoneal tumors constitute a difficult diagnostic category as they are not easily accessible. The advent of image-guided fine-needle aspiration (FNA) has resolved this problem significantly. We present a short study based on guided aspiration of retroperitoneal tumors, in which we have tried to assess the role of image-guided fine-needle aspiration cytology as a tool for pre-operative diagnosis. The study was conducted on patients diagnosed with retroperitoneal masses. FNA was performed under image guidance with the help of ultrasonography and/or computed tomography; smears were prepared and meticulously screened according to a fixed protocol. The results were analyzed to determine sensitivity, specificity, and diagnostic efficacy of cytopathological diagnosis using image-guided FNA techniques. We assessed 38 patients with retroperitoneal masses. In all cases, adequate cellular material was obtained. No major complications were encountered. Statistical analysis was carried out in 35 cases; sensitivity, specificity, and diagnostic accuracy were 100% in these cases. FNA under image guidance should be considered a first-line diagnostic approach for retroperitoneal and other abdominal tumors, although caution should be exercised in case selection. In areas where advanced tests are not available, the cytotechnologist and cytopathologist have a very important role to play in ensuring accurate diagnoses.

  19. Intraoral ultrasonography: development of a specific high-frequency probe and clinical pilot study.

    PubMed

    Salmon, Benjamin; Le Denmat, Dominique

    2012-04-01

    Although ultrasonography is a non-invasive, inexpensive and painless diagnostic tool for soft tissue imaging, this technique is not currently used for oral exploration. Therefore, we developed a 25-MHz high-frequency ultrasound probe, specially designed for intraoral applications. This paper aims to present clinical intraoral ultrasound images actually interpretable, in order to identify the relevant applications of this novel tool and to design future oral studies. Two independent radiologists performed ultrasound examinations on three healthy volunteers. All the teeth were explored on the lingual and buccal sides (162 samples) to evaluate the ergonomics of the system and the visualisation of anatomic structures. Osseointegrated dental implants and a mucocele were also scanned. At the gingivodental junction of the maxillary and mandibular teeth, the device clearly identifies the tooth surfaces, the alveolar bone reflection with its surrounding subepithelial connective tissue of the gingiva and the gingival epithelia. The bone level and the thickness of soft tissue around the implant are measurable on the buccal and lingual sides. Therefore, intraoral ultrasonography provides additional morphological information that is not accessible by conventional dental x-rays. We propose a novel diagnostic tool that explores the biological width and is able to define the thin or thick nature of the gums. Moreover, intraoral ultrasonography may help to monitor precancerous lesions. This promising device requires large-scale clinical studies to determine whether it should remain a research tool or be used as a diagnostic tool for daily dental practice.

  20. Comparison of Radiography and Ultrasonography for Diagnosis of Diaphragmatic Hernia in Bovines

    PubMed Central

    Athar, Hakim; Mohindroo, Jitender; Singh, Kiranjeet; Kumar, Ashwani; Raghunath, Mulinti

    2010-01-01

    The present study was conducted on 101 animals suffering from thoracoabdominal disorders; out of which twenty seven animals (twenty six buffaloes and one cow) were diagnosed with diaphragmatic hernia based on clinical signs, radiography, ultrasonography, and left flank laparorumenotomy. Radiography alone confirmed diaphragmatic hernia in 18 cases (66.67%) with a sac-like structure cranial to the diaphragm. In 15 animals the sac contained metallic densities while in three cases a sac-like structure with no metallic densities was present. Ultrasonography was helpful in confirming diaphragmatic hernia in 23 cases (85.18%) and ultrasonographically reticular motility was evident at the level of 4th/5th intercostal space in all the animals. B+M mode ultrasonography was used for the first time for diagnosis of diaphragmatic hernia in bovines and the results suggested that ultrasonography was a reliable diagnostic modality for diaphragmatic hernia in bovines. PMID:20445795

  1. [Intraoperative ultrasonography during laparoscopic surgery].

    PubMed

    Alecu, L; Lungu, C; Pascu, A; Costan, I; Corodeanu, G; Deacu, A; Marin, A

    2000-01-01

    Of this study is the introduction and the results evaluation of laparoscopic ultrasonography performed. We realize a prospective study about laparoscopic ultrasonography performed in 37 cases with laparoscopic surgical treatment. The Aloka SSD 2000 mobile scanner is used. This system make possible the use of an linear-array transducer, with mechanical flexibility and availability of Doppler analysis. Most frequently we used intraoperative ultrasonography in laparoscopic cholecystectomy as an alternative for cholangiography to exclude CBD pathology. Because of various surgical pathology with laparoscopic approach, the laparoscopic ultrasonography utilization range was vastly. In all the cases we could performed the laparoscopic ultrasonography. In 6 of 27 cases with laparoscopic cholecystectomy we found pathological disorders of bile ducts. CBD with diameter found between 5-12 mm. We properly saw the distal segment of CBD in 23 cases (89.2%), and common hepatic duct in 26 cases (97.3%). The quality of visualization was very good in 21 cases (83.8%) and moderate in 6 cases (16.2%). We easy identify CBD stones and we successfully used Doppler color mode in differentiating vascular from non-vascular from non-vascular structures. Laparoscopic ultrasonography performed in a case with left colon cancer excluded liver metastasis and lymph nodes metastasis. 1. Laparoscopic ultrasonography combines the advantages of diagnostic laparoscopy and intraoperative contact ultrasonography; 2. Laparoscopic ultrasonography is a simple and very efficient intraoperative examination procedure; 3. Laparoscopic ultrasonography is the technique to choose in CBD intraoperative exploration; 4. Laparoscopic ultrasonography improve abdominal malignancy exploration, thus modifying therapeutic decisions; 5. Color Doppler mode guides the surgeon's steps in difficult directions.

  2. Errors in imaging patients in the emergency setting

    PubMed Central

    Reginelli, Alfonso; Lo Re, Giuseppe; Midiri, Federico; Muzj, Carlo; Romano, Luigia; Brunese, Luca

    2016-01-01

    Emergency and trauma care produces a “perfect storm” for radiological errors: uncooperative patients, inadequate histories, time-critical decisions, concurrent tasks and often junior personnel working after hours in busy emergency departments. The main cause of diagnostic errors in the emergency department is the failure to correctly interpret radiographs, and the majority of diagnoses missed on radiographs are fractures. Missed diagnoses potentially have important consequences for patients, clinicians and radiologists. Radiologists play a pivotal role in the diagnostic assessment of polytrauma patients and of patients with non-traumatic craniothoracoabdominal emergencies, and key elements to reduce errors in the emergency setting are knowledge, experience and the correct application of imaging protocols. This article aims to highlight the definition and classification of errors in radiology, the causes of errors in emergency radiology and the spectrum of diagnostic errors in radiography, ultrasonography and CT in the emergency setting. PMID:26838955

  3. Errors in imaging patients in the emergency setting.

    PubMed

    Pinto, Antonio; Reginelli, Alfonso; Pinto, Fabio; Lo Re, Giuseppe; Midiri, Federico; Muzj, Carlo; Romano, Luigia; Brunese, Luca

    2016-01-01

    Emergency and trauma care produces a "perfect storm" for radiological errors: uncooperative patients, inadequate histories, time-critical decisions, concurrent tasks and often junior personnel working after hours in busy emergency departments. The main cause of diagnostic errors in the emergency department is the failure to correctly interpret radiographs, and the majority of diagnoses missed on radiographs are fractures. Missed diagnoses potentially have important consequences for patients, clinicians and radiologists. Radiologists play a pivotal role in the diagnostic assessment of polytrauma patients and of patients with non-traumatic craniothoracoabdominal emergencies, and key elements to reduce errors in the emergency setting are knowledge, experience and the correct application of imaging protocols. This article aims to highlight the definition and classification of errors in radiology, the causes of errors in emergency radiology and the spectrum of diagnostic errors in radiography, ultrasonography and CT in the emergency setting.

  4. Immersion ultrasonography: simultaneous A-scan and B-scan.

    PubMed

    Coleman, D J; Dallow, R L; Smith, M E

    1979-01-01

    In eyes with opaque media, ophthalmic ultrasound provides a unique source of information that can dramatically affect the course of patient management. In addition, when an ocular abnormality can be visualized, ultrasonography provides information that supplements and complements other diagnostic testing. It provides documentation and differentiation of abnormal states, such as vitreous hemorrhage and intraocular tumor, as well as differentiation of orbital tumors from inflammatory causes of exophthalmos. Additional capabilities of ultrasound are biometric determinations for calculation of intraocular lens implant powers and drug-effectiveness studies. Maximal information is derived from ultrasonography when A-scan and B-scan techniques are employed simultaneously. Flexibility of electronics, variable-frequency transducers, and the use of several different manual scanning patterns aid in detection and interpretation of results. The immersion system of ultrasonography provides these features optimally.

  5. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    PubMed

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  6. Assessment of ultrasonography and computed tomography for the evaluation of unilateral orbital disease in dogs.

    PubMed

    Boroffka, Susanne A E B; Verbruggen, Anne-Marie; Grinwis, Guy C M; Voorhout, George; Barthez, Paul Y

    2007-03-01

    To describe clinical, ultrasonographic, and computed tomographic (CT) features of confirmed neoplastic and nonneoplastic disease in dogs with unilateral orbital diseases, determine criteria to differentiate between the 2 conditions, and assess the relative value of ultrasonography and CT for the differential diagnosis of these 2 conditions. Prospective study. 29 dogs with unilateral neoplastic orbital disease and 16 dogs with unilateral nonneoplastic orbital disease. Clinical history and results of physical and ophthalmologic examinations were recorded. Ultrasonographic and CT images were evaluated, and discriminating factors were identified to differentiate neoplastic from nonneoplastic diseases. Diagnostic value of ultrasonography and CT was assessed. Dogs with neoplastic disease were significantly older; had clinical signs for a longer time before initial examination; had more progressive onset of clinical signs; and more frequently had protrusion of the nictitating membrane, fever, and anorexia. The most discriminating factor for both imaging modalities was delineation of the margins (odds ratio was 41.7 for ultrasonography and 45 for CT), with neoplastic lesions clearly delineated more often. Ultrasonographically, neoplastic lesions were more frequently hypoechoic and homogeneous, with indentation of the globe and bone involvement evident more frequently than for nonneoplastic lesions. Mineralization was detected only with neoplasia. Fluctuant fluid was seen more frequently in dogs with nonneoplastic disease. Computed tomography more frequently revealed extraorbital involvement. Diagnostic value was similar for both imaging modalities. Ultrasonography and CT are valuable imaging modalities to assist in differentiating neoplastic from nonneoplastic unilateral orbital disease in dogs.

  7. Competency-based assessment in surgeon-performed head and neck ultrasonography: A validity study.

    PubMed

    Todsen, Tobias; Melchiors, Jacob; Charabi, Birgitte; Henriksen, Birthe; Ringsted, Charlotte; Konge, Lars; von Buchwald, Christian

    2018-06-01

    Head and neck ultrasonography (HNUS) increasingly is used as a point-of-care diagnostic tool by otolaryngologists. However, ultrasonography (US) is a very operator-dependent image modality. Hence, this study aimed to explore the diagnostic accuracy of surgeon-performed HNUS and to establish validity evidence for an objective structured assessment of ultrasound skills (OSAUS) used for competency-based assessment. A prospective experimental study. Six otolaryngologists and 11 US novices were included in a standardized test setup for which they had to perform focused HNUS of eight patients suspected for different head and neck lesions. Their diagnostic accuracy was calculated based on the US reports, and two blinded raters assessed the video-recorded US performance using the OSAUS scale. The otolaryngologists obtained a high diagnostic accuracy on 88% (range 63%-100%) compared to the US novices on 38% (range 0-63%); P < 0.001. The OSAUS score demonstrated good inter-case reliability (0.85) and inter-rater reliability (0.76), and significant discrimination between otolaryngologist and US novices; P < 0.001. A strong correlation between the OSAUS score and the diagnostic accuracy was found (Spearman's ρ, 0.85; P < P 0.001), and a pass/fail score was established at 2.8. Strong validity evidence supported the use of the OSAUS scale to assess HNUS competence with good reliability, significant discrimination between US competence levels, and a strong correlation of assessment score to diagnostic accuracy. An OSAUS pass/fail score was established and could be used for competence-based assessment in surgeon-performed HNUS. NA. Laryngoscope, 128:1346-1352, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Novel and Practical Scoring Systems for the Diagnosis of Thyroid Nodules

    PubMed Central

    Wei, Ying; Zhou, Xinrong; Liu, Siyue; Wang, Hong; Liu, Limin; Liu, Renze; Kang, Jinsong; Hong, Kai; Wang, Daowen; Yuan, Gang

    2016-01-01

    Objective The clinical management of patients with thyroid nodules that are biopsied by fine-needle aspiration cytology and yield indeterminate results remains unsettled. The BRAF V600E mutation has dubious diagnostic value due to its low sensitivity. Novel strategies are urgently needed to distinguish thyroid malignancies from thyroid nodules. Design This prospective study included 504 thyroid nodules diagnosed by ultrasonography from 468 patients, and fine-needle aspiration cytology was performed under ultrasound guidance. Cytology and molecular analysis, including BRAF V600E, RET/PTC1 and RET/PTC3, were conducted simultaneously. The cytology, ultrasonography results, and mutational status were gathered and analyzed together. Predictive scoring systems were designed using a combination of diagnostic parameters for ultrasonography, cytology and genetic analysis. The utility of the scoring systems was analyzed and compared to detection using the individual methods alone or combined. Result The sensitivity of scoring systema (ultrasonography, cytology, BRAF V600E, RET/PTC) was nearly identical to that of scoring systemb (ultrasonography, cytology, BRAF V600E); these were 91.0% and 90.2%, respectively. These sensitivities were significantly higher than those obtained using FNAC, genetic analysis and US alone or combined; their sensitivities were 63.9%, 70.7% and 87.2%, respectively. Scoring systemc (ultrasonography, cytology) was slightly inferior to the former two scoring systems but still had relatively high sensitivity and specificity (80.5% and 95.1%, respectively), which were significantly superior to those of single cytology, ultrasonography or genetic analysis. In nodules with uncertainty cytology, scoring systema, scoring systemb and scoring systemc could elevate the malignancy detection rates to 69.7%, 69.7% and 63.6%, respectively. Conclusion These three scoring systems were quick for clinicians to master and could provide quantified information to predict the probability of malignant nodules. Scoring systemb is recommended for improving the detection rate among nodules of uncertain cytology. PMID:27654865

  9. [The diagnostic performance of color Doppler ultrasonography for newborn four cases of midgut volvulus accompanied by intestinal malrotation].

    PubMed

    Ikeshima, Yukari; Hisano, Katsuya; Morisawa, Takeshi; Inoue, Kozue; Shimamoto, Masahiro; Koujitani, Toshiaki; Yonetani, Masahiko; Yasufuku, Masao

    2014-03-01

    Midgut volvulus accompanied by intestinal malrotation is classified as a surgical emergency disease of the newborn, which emerges with the bilious vomiting or melena. This report presents four patients of this disease in our hospital, evaluated by color Doppler ultrasonography before surgical operation. All four patients were presented by bilious vomiting at the onset. By color Doppler ultrasonography method, the whirlpool sign which is the view of intestine and superior mesenteric vein rotated around with the axis of superior mesenteric artery, were shown in all cases. This whirlpool sign led to the diagnosis of midgut volvulus accompanied by intestinal malrotation. Intestinal contrast imaging was tested in three patients for the purpose of confirming the diagnosis. Repair of the volvulus and a ladd operation was performed in all four patients, without the excision of intestine because of no intestinal ischemic change. The clinical courses of four cases were good, and all patients were discharged within 17 days. Early diagnosis and timely surgical operation are essential for decreasing the possibility of occurring intestinal ischemic changes and improving clinical outcome after surgical operation. We propose that color Doppler ultrasonography is the powerful tool for the diagnosis of this disease, especially for the newborn, for whom the available diagnostic tests are limited.

  10. Diagnostic Thyroidectomy May Be Preferable in Patients With Suspicious Ultrasonography Features After Cytopathology Diagnosis of AUS/FLUS in the Bethesda System

    PubMed Central

    Lee, Yong Sang; Kim, Hyeung Kyoo; Chang, Hojin; Kim, Seok Mo; Kim, Bup-Woo; Chang, Hang-Seok; Park, Cheong Soo

    2015-01-01

    Abstract Atypia/follicular lesion of undetermined significance (AUS/FLUS) is a new category in the Bethesda System for Reporting Thyroid Cytopathology (BSRTC) for which repeat fine-needle aspiration cytology (FNAC) is recommended. The aim of this study was to identify specific ultrasonography and clinical predictors of malignancy in a subset of thyroid nodules associated with cytology diagnoses of AUS/FLUS. Between January 2011 and December 2102, 5440 patients underwent thyroid surgery at our institution. Of these, 213 patients were diagnosed AUS/FLUS at the preoperative cytopathology diagnosis. The frequency of FNAC and ultrasonography images was compared between patients with cancerous and benign tumors based on their final pathology. Of the 213 patients, 158 (74.2%) were diagnosed with thyroid carcinoma in their final pathology reports. In univariate and multivariate analyses, the frequency of FNAC was not significantly correlated with the cancer diagnosis. Hypoechogenicity (odds ratio 2.521, P = 0.007) and microcalcification (odds ratio 3.247, P = 0.005) were statistically correlated with cancer risk. Although AUS/FLUS in cytopathology is recommended for repeating FNAC in BSRTC, we proposed that thyroid nodules with ultrasonography findings that suggest the possibility of cancer should undergo thyroidectomy with diagnostic intent. PMID:26705204

  11. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    PubMed Central

    Znajdek, Michał; Gietka, Piotr; Vasilevska-Nikodinovska, Violeta; Patrovic, Lukas; Salapura, Vladka

    2017-01-01

    Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging. PMID:29075522

  12. Diagnosis of Nipple Discharge: Value of Magnetic Resonance Imaging and Ultrasonography in Comparison with Ductoscopy.

    PubMed

    Yılmaz, Ravza; Bender, Ömer; Çelik Yabul, Fatma; Dursun, Menduh; Tunacı, Mehtap; Acunas, Gülden

    2017-04-05

    Pathologic nipple discharge, which is a common reason for referral to the breast imaging service, refers to spontaneous or bloody nipple discharge that arises from a single duct. The most common cause of nipple discharge is benign breast lesions, such as solitary intraductal papilloma and papillomatosis. Nevertheless, in rare cases, a malignant cause of nipple discharge can be found. To study the diagnostic value of ultrasonography, magnetic resonance imaging, and ductoscopy in patients with pathologic nipple discharge, compare their efficacy, and investigate the importance of magnetic resonance imaging in the diagnosis of intraductal pathologies. Diagnostic accuracy study. Fifty patients with pathologic nipple discharge were evaluated by ultrasonography and magnetic resonance imaging. Of these, 44 ductoscopic investigations were made. The patients were classified according to magnetic resonance imaging, ultrasonography, and ductoscopy findings. A total of 25 patients, whose findings were reported as intraductal masses, underwent surgery oincluding endoscopic excision for two endoscopic excision. Findings were compared with the pathology results that were accepted as the gold standard in the description of the aetiology of nipple discharge. In addition, magnetic resonance imaging, ultrasonography and ductoscopy findings were analysed comparatively in patients who had no surgery. Intraductal masses were reported in 26 patients, 20 of whom operated and established accurate diagnosis of 18 patients on magnetic resonance imaging. According to the ultrasonography, intraductal masses were identified in 22 patients, 17 of whom underwent surgery. Ultrasonography established accurate diagnoses in 15 patients. Intraductal mass was identified in 22 patients and ductoscopy established accurate diagnoses based on histopathologic results in 16 patients. The sensitivities of methods were 75% in ultrasonography, 90% in magnetic resonance imaging, and 94.6% in ductoscopy. The specificities were 66.7% in ultrasonography, 66.7% in magnetic resonance imaging, and 40% in ductoscopy. Intraductal papillomas were mostly observed as oval nodules with well-circumscribed smooth margins within dilated ducts and persistant in the dynamic analysis. Lesions that protruded into the lumen of the ducts, either solitary or multiple, were characteristic ductoscopy findings of our patients who were diagnosed as having papilloma/papillomatosis. Magnetic resonance imaging and ductoscopy had no statistical superiority over each other, however they were superior to ultrasonography in the diagnosis of pathologic nipple discharge. Magnetic resonance imaging may be highly sensitive for diagnosing nipple discharge with new techniques and sequences and a non-invasive method that more advantageous for showing ductal tree visualization and is able to detect completely obstructed intraductal lesions.

  13. Endobronchial ultrasonography using a guide sheath technique for diagnosis of peripheral pulmonary lesions

    PubMed Central

    Zhang, Lei; Wu, Hongxu; Wang, Guiqi

    2017-01-01

    Endobronchial ultrasonography using a guide sheath (EBUS-GS) is a novel method used for collecting peripheral pulmonary lesion (PPL) samples. EBUS-GS is performed by introducing a guide sheath-covered miniprobe into the target bronchus and then withdrawing the miniprobe after lesion detection, leaving the guide sheath in situ as a working channel for obtaining lesion samples. EBUS-GS can improve PPL diagnosis rates and be used for obtaining specimens for molecular analysis. In this review, we discuss the clinical applications of EBUS-GS, the factors that affect its diagnostic sensitivity, and potential complications. We also compare EBUS-GS with other available diagnostic techniques and discuss the strengths and limitations of this method. PMID:29063872

  14. Dynamic Ultrasonography of the Deep External Rotator Musculature of the Hip: A Descriptive Study.

    PubMed

    Battaglia, Patrick J; Mattox, Ross; Haun, Daniel W; Welk, Aaron B; Kettner, Norman W

    2016-07-01

    No detailed reports exist describing the methodology of ultrasound image acquisition of the deep external rotator muscles of the hip. Because gluteal pain and sciatica are common, ultrasound may be a useful dynamic imaging adjunct in the evaluation of these patients. To describe dynamic ultrasonography of the deep external rotator muscles of the hip for diagnostic purposes. Descriptive. University radiology department. Participants (n = 25; 14 male) without gluteal pain or sciatica were enrolled (mean age 27.6 ± 4.7 years; mean body mass index 26.0 ± 4.1 kg/m(2)). Ultrasonographic cine clips oriented to the long axis of each deep external rotator muscle were captured. In addition, cine clips of the piriformis tendon and obturator internus tendon were obtained. Cine clips were analyzed approximately 1 week after completion of image acquisition independently by 2 blinded raters. A 5-point Likert scale to evaluate the diagnostic utility of the ultrasound image. The modal Likert scores for rater 1 were as follows: piriformis muscle = 4; piriformis tendon = 4; superior gemellus muscle = 3; obturator internus muscle = 4; obturator internus tendon = 4; inferior gemellus muscle = 4; quadratus femoris muscle = 4. The modal scores for rater 2 were: piriformis muscle = 4; piriformis tendon = 3; superior gemellus muscle = 4; obturator internus muscle = 3; obturator internus tendon = 4; inferior gemellus muscle = 3; quadratus femoris muscle = 4. Dynamic ultrasonography may be useful to image the hip deep external rotator musculature for diagnostic purposes and therefore aid in the evaluation of gluteal pain and sciatica. Future work should investigate the reliability and validity of ultrasonography in the evaluation of pathology of these muscles. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  15. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    PubMed

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  16. COMPARISON BETWEEN COMPUTED TOMOGRAPHIC ARTHROGRAPHY, RADIOGRAPHY, ULTRASONOGRAPHY, AND ARTHROSCOPY FOR THE DIAGNOSIS OF FEMOROTIBIAL JOINT DISEASE IN WESTERN PERFORMANCE HORSES.

    PubMed

    Nelson, Brad B; Kawcak, Chris E; Goodrich, Laurie R; Werpy, Natasha M; Valdés-Martínez, Alejandro; McIlwraith, C Wayne

    2016-07-01

    The femorotibial joints are a common source of lameness in Western performance horses. The objective of this prospective study was to compare the radiography, ultrasonography, computed tomographic arthrography (CTA), and arthroscopy findings in horses with lameness localized to the femorotibial joints. Twenty-five stifles in 24 horses were included and were evaluated with all four of these diagnostic methods. Defects detected in femorotibial joint structures were compared between diagnostic methods using a McNemar's test to evaluate for disagreement. Cranial medial meniscotibial desmopathy was most detected on arthroscopy (in 14/25 cases) and was only detected on ultrasonography in three out of 11 (27.3%) arthroscopically observed cases, but was detected on CTA in nine out of 12 (75%) arthroscopically observed cases. Medial meniscal injury located on the craniolateral border was most detected on arthroscopy (n = 9) and was detected on CTA in five cases, but on ultrasonography in 0 cases. Detection of articular cartilage defects on the medial femoral condyle was most detected with arthroscopy (24/25, 96% cases) and was also detected on CTA in 12/20 (60%) cases with a significant disagreement identified between modalities (P = 0.02). Cranial and caudal cruciate ligament defects were detected on CTA in 6/22 (27.3%) and 7/19 (36.8%) cases, respectively, and with arthroscopy in 3/25 (12%) and 2/25 (8%) cases, respectively. The use of CTA detected more defects in the cruciate ligaments, proximal tibia, and ligament entheses than the other diagnostic methods, but was not reliable for detection of articular cartilage damage on the medial femoral condyle. © 2016 American College of Veterinary Radiology.

  17. Grey-scale ultrasonography for monitoring industrial exposure to hepatotoxic agents.

    PubMed

    Taylor, K J; Williams, D M; Smith, P M; Duck, B W

    1975-05-31

    Industrial exposure to several potentially hepatotoxic agents, such as vinyl-chloride monomer may occur, and there is a need for non-vasive, diagnostic techniques to detect and monitor progressive pathological processes in liver or spleen. Grey-scale ultrasonography permits display of detailed anatomy and pathology in the liver, portal veins, and spleen. The combination of fine resolution, non-invasiveness, absence of ionising radiation hazard, and portable equipment makes the technique ideal for screening populations at risk.

  18. [Ultrasound diagnostics of muscle and tendon injuries].

    PubMed

    Stević, Ruza; Masulović, Dragan

    2009-01-01

    Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow- up of healing process. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. The study included 170 patients (148 male and 22 female), mean age 29.6 years (range 14-60 years). All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Traumatic lesions of muscles were diagnosed in 113 patients (66.7%) and tendon injuries in 57 cases (33.2%). The muscle changes detected by ultrasonography were the following: 70 (61.9%) partial and two (1.76%) complete ruptures, 22 (19.46%) haematoma, 9 (7.96%) strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively). Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8%) ruptures and 36 (66.1%) tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  19. Application of Ultrasonography and Radiography in Detection of Hemothorax; a Systematic Review and Meta-Analysis.

    PubMed

    Rahimi-Movaghar, Vafa; Yousefifard, Mahmoud; Ghelichkhani, Parisa; Baikpour, Masoud; Tafakhori, Abbas; Asady, Hadi; Faridaalaee, Gholamreza; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography and radiography in detection of hemothorax through a systematic review and meta-analysis. Two independent reviewers performed an extended systematic search in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Data were extract and quality of the relevant studies were assessed. The number of true positive, false positive, true negative and false negative cases were extracted and screening performance characteristics of two imaging techniques were calculated using a mixed-effects binary regression model. Data from 12 studies were extracted and included in the meta-analysis (7361 patients, 77.1% male). Pooled sensitivity and specificity of ultrasonography in detection of hemothorax were 0.67 (95% CI: 0.41-0.86; I2= 68.38, p<0.001) and 0.99 (95% CI: 0.95-1.0; I2= 88.16, p<0.001), respectively. These measures for radiography were 0.54 (95% CI: 0.33-0.75; I2= 92.85, p<0.001) and 0.99 (95% CI: 0.94-1.0; I2= 99.22, p<0.001), respectively. Subgroup analysis found operator of the ultrasonography device, frequency of the transducer and sample size to be important sources of heterogeneity of included studies. The results of this study showed that although the sensitivity of ultrasonography in detection of hemothorax is relatively higher than radiography, but it is still at a moderate level (0.67%). The specificity of both imaging modalities were found to be at an excellent level in this regard. The screening characteristics of ultrasonography was found to be influenced of the operator and frequency of transducer.

  20. Comparison of the accuracy of radiography and ultrasonography for detection of articular lesions in horses.

    PubMed

    Hinz, Antje; Fischer, Andrew T

    2011-10-01

    To compare the accuracy of ultrasonographic and radiographic examination for evaluation of articular lesions in horses. Cross-sectional study. Horses (n = 137) with articular lesions. Radiographic and ultrasonographic examinations of the affected joint(s) were performed before diagnostic or therapeutic arthroscopic surgery. Findings were recorded and compared to lesions identified during arthroscopy. In 254 joints, 432 lesions were identified by arthroscopy. The overall accuracy was 82.9% for ultrasonography and 62.2% for radiography (P < .0001) with a sensitivity of 91.4% for ultrasonography and 66.7% for radiography (P < .0001). The difference in specificity was not statistically significant (P = .2628). The negative predictive value for ultrasonography was 31.5% and 13.2% for radiography (P = .0022), the difference for the positive predictive value was not statistically significant (P = .3898). The accuracy for ultrasonography and radiography for left versus right joints was equal and corresponded with the overall results. Ultrasonographic evaluation of articular lesions was more accurate than radiographic evaluation. © Copyright 2011 by The American College of Veterinary Surgeons.

  1. Advances in diagnostic interventional pulmonology

    PubMed Central

    Al-Zubaidi, Nassar; Soubani, Ayman O.

    2015-01-01

    The recent advances in diagnostic pulmonary procedures have revolutionized the evaluation of abnormal thoracic findings including lung nodules and masses, mediastinal lymphadenopathy, and pleural diseases. Bronchoscopies with endobronchial ultrasonography and electromagnetic navigation are examples of new technology that has significantly improved the specificity and sensitivity of these procedures in diagnosis and staging of lung cancer without the need for more invasive procedures. This report describes the different diagnostic pulmonary interventions providing a description of the procedures, their indications, diagnostic yield and drawback. PMID:26229756

  2. Diagnostic accuracy of a novel software technology for detecting pneumothorax in a porcine model.

    PubMed

    Summers, Shane M; Chin, Eric J; April, Michael D; Grisell, Ronald D; Lospinoso, Joshua A; Kheirabadi, Bijan S; Salinas, Jose; Blackbourne, Lorne H

    2017-09-01

    Our objective was to measure the diagnostic accuracy of a novel software technology to detect pneumothorax on Brightness (B) mode and Motion (M) mode ultrasonography. Ultrasonography fellowship-trained emergency physicians performed thoracic ultrasonography at baseline and after surgically creating a pneumothorax in eight intubated, spontaneously breathing porcine subjects. Prior to pneumothorax induction, we captured sagittal M-mode still images and B-mode videos of each intercostal space with a linear array transducer at 4cm of depth. After collection of baseline images, we placed a chest tube, injected air into the pleural space in 250mL increments, and repeated the ultrasonography for pneumothorax volumes of 250mL, 500mL, 750mL, and 1000mL. We confirmed pneumothorax with intrapleural digital manometry and ultrasound by expert sonographers. We exported collected images for interpretation by the software. We treated each individual scan as a single test for interpretation by the software. Excluding indeterminate results, we collected 338M-mode images for which the software demonstrated a sensitivity of 98% (95% confidence interval [CI] 92-99%), specificity of 95% (95% CI 86-99), positive likelihood ratio (LR+) of 21.6 (95% CI 7.1-65), and negative likelihood ratio (LR-) of 0.02 (95% CI 0.008-0.046). Among 364 B-mode videos, the software demonstrated a sensitivity of 86% (95% CI 81-90%), specificity of 85% (81-91%), LR+ of 5.7 (95% CI 3.2-10.2), and LR- of 0.17 (95% CI 0.12-0.22). This novel technology has potential as a useful adjunct to diagnose pneumothorax on thoracic ultrasonography. Published by Elsevier Inc.

  3. [Pancreatic ultrasonography].

    PubMed

    Fernández-Rodríguez, T; Segura-Grau, A; Rodríguez-Lorenzo, A; Segura-Cabral, J M

    2015-04-01

    Despite the recent technological advances in imaging, abdominal ultrasonography continues to be the first diagnostic test indicated in patients with a suspicion of pancreatic disease, due to its safety, accessibility and low cost. It is an essential technique in the study of inflammatory processes, since it not only assesses changes in pancreatic parenchyma, but also gives an indication of the origin (bile or alcoholic). It is also essential in the detection and tracing of possible complications as well as being used as a guide in diagnostic and therapeutic punctures. It is also the first technique used in the study of pancreatic tumors, detecting them with a sensitivity of around 70% and a specificity of 90%. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  4. B-scan ultrasonography for the detection of space-occupying ocular masses.

    PubMed

    Miller, W W; Cartee, R E

    1985-07-01

    A noninvasive technique, B-scan ultrasonography, was used to obtain detailed cross-sectional images of ocular and orbital structure and form. When a low-frequency probe (5 MHz) was used, tissue penetration was excellent; however, axial resolution was limited. The technique was used in a study of 2 cats and 1 dog. The use of low-frequency B-scan ultrasound should aid in the diagnostic examinations of space-occupying masses in the posterior portion of the ocular bulb and the orbit.

  5. [Prostatic abscess: diagnosis and treatment].

    PubMed

    Franco, A; Menéndez, V; Luque, M P; Ribal, M J; Mallafre, J M; Alcover, J; Vilana, R; Carretero, P

    1996-02-01

    Prostatic abscesses are an infrequent pathology, probably due to a better and early management of prostatic infections. Predisposing factors in this pathology are diabetes mellitus, urethral catheterism or manipulation, and immunodepressed states like AIDS. Nowadays, ultrasonography is an excellent diagnostic method of this pathology, and serves as a guidance of directed drainage. We present five cases in which the size of the abscess was determining in relation to the therapeutic attitude. Abscesses of less than 2 cm, measured by transrectal ultrasonography, can be evacuated by directed puncture, followed by antibiotic treatment. When the diameter of the abscess is greater than 2 cm, we realize a perineal drainage with a catheter placed with transrectal ultrasonography. Currently, TUR and other methods seems to be overcome.

  6. The cost-effectiveness of iodine 131 scintigraphy, ultrasonography, and fine-needle aspiration biopsy in the initial diagnosis of solitary thyroid nodules.

    PubMed

    Khalid, Ayesha N; Hollenbeak, Christopher S; Quraishi, Sadeq A; Fan, Chris Y; Stack, Brendan C

    2006-03-01

    To compare the cost-effectiveness of fine-needle aspiration biopsy, iodine 131 scintigraphy, and ultrasonography for the initial diagnostic workup of a solitary palpable thyroid nodule. A deterministic cost-effectiveness analysis was conducted using a decision tree to model the diagnostic strategies. A single, mid-Atlantic academic medical center. Expected costs, expected number of cases correctly diagnosed, and incremental cost per additional case correctly diagnosed. Relative to the routine use of fine-needle aspiration biopsy, the incremental cost per case correctly diagnosed is 24,554 dollars for the iodine 131 scintigraphy strategy and 1212 dollars for the ultrasound strategy. A diagnostic strategy using initial fine-needle aspiration biopsy for palpable thyroid nodules was found to be cost-effective compared with the other approaches as long as a payor's willingness to pay for an additional correct diagnosis is less than 1212 dollars. Prospective studies are needed to validate these finding in clinical practice.

  7. Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use.

    PubMed

    Rella, Rossella; Belli, Paolo; Giuliani, Michela; Bufi, Enida; Carlino, Giorgio; Rinaldi, Pierluigi; Manfredi, Riccardo

    2018-03-16

    Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Committee Opinion No. 723 Summary: Guidelines for Diagnostic Imaging During Pregnancy and Lactation.

    PubMed

    2017-10-01

    Imaging studies are important adjuncts in the diagnostic evaluation of acute and chronic conditions. However, confusion about the safety of these modalities for pregnant and lactating women and their infants often results in unnecessary avoidance of useful diagnostic tests or the unnecessary interruption of breastfeeding. Ultrasonography and magnetic resonance imaging are not associated with risk and are the imaging techniques of choice for the pregnant patient, but they should be used prudently and only when use is expected to answer a relevant clinical question or otherwise provide medical benefit to the patient. With few exceptions, radiation exposure through radiography, computed tomography scan, or nuclear medicine imaging techniques is at a dose much lower than the exposure associated with fetal harm. If these techniques are necessary in addition to ultrasonography or magnetic resonance imaging or are more readily available for the diagnosis in question, they should not be withheld from a pregnant patient. Breastfeeding should not be interrupted after gadolinium administration.

  9. Committee Opinion No. 723: Guidelines for Diagnostic Imaging During Pregnancy and Lactation.

    PubMed

    2017-10-01

    Imaging studies are important adjuncts in the diagnostic evaluation of acute and chronic conditions. However, confusion about the safety of these modalities for pregnant and lactating women and their infants often results in unnecessary avoidance of useful diagnostic tests or the unnecessary interruption of breastfeeding. Ultrasonography and magnetic resonance imaging are not associated with risk and are the imaging techniques of choice for the pregnant patient, but they should be used prudently and only when use is expected to answer a relevant clinical question or otherwise provide medical benefit to the patient. With few exceptions, radiation exposure through radiography, computed tomography scan, or nuclear medicine imaging techniques is at a dose much lower than the exposure associated with fetal harm. If these techniques are necessary in addition to ultrasonography or magnetic resonance imaging or are more readily available for the diagnosis in question, they should not be withheld from a pregnant patient. Breastfeeding should not be interrupted after gadolinium administration.

  10. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study.

    PubMed

    Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel

    2012-01-01

    To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  11. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study

    PubMed Central

    Zuhur, Sayid Shafi; Özel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Çil, Esra; Altuntas, Yüksel

    2012-01-01

    OBJECTIVE: To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. METHODS: The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age- and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. RESULTS: The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. CONCLUSIONS: This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. PMID:22358236

  12. Learning curve of office-based ultrasonography for rotator cuff tendons tears.

    PubMed

    Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook

    2013-07-01

    To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.

  13. Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta- Analysis

    PubMed

    Nafisi Moghadam, Reza; Amlelshahbaz, Amir Pasha; Namiranian, Nasim; Sobhan-Ardekani, Mohammad; Emami-Meybodi, Mahmood; Dehghan, Ali; Rahmanian, Masoud; Razavi-Ratki, Seid Kazem

    2017-12-28

    Objective: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid adenoma with a systematic review and meta-analysis of the literature. Methods: Pub Med, Scopus (EMbase), Web of Science and the reference lists of all included studies were searched up to 1st January 2016. The search strategy was according PICO characteristics. Heterogeneity between the studies was accounted by P < 0.1. Point estimates were pooled estimate of sensitivity, specificity and positive predictive value of SPECT and ultrasonography with 99% confidence intervals (CIs) by pooling available data. Data analysis was performed using Meta-DiSc software (version 1.4). Results: Among 188 studies and after deletion of duplicated studies (75), a total of 113 titles and abstracts were studied. From these, 12 studies were selected. The meta-analysis determined a pooled sensitivity for scintigraphy of 83% [99% confidence interval (CI) 96.358 -97.412] and for ultra-sonography of 80% [99% confidence interval (CI) 76-83]. Similar results for specificity were also obtained for both approache. Conclusion: According this meta- analysis, there were no significant differences between the two methods in terms of sensitivity and specificity. There were overlaps in 99% confidence intervals. Also features of the two methods are similar. Creative Commons Attribution License

  14. [Complex ultrasonic study of parathyroids in diagnostic and surgical treatment of primary hyperparathyroidism].

    PubMed

    Chernousov, A F; Ippolitov, L I; Musaev, G Kh; Saliba, M B

    2014-01-01

    Primary hyperparathyroidism is the most common disease in Russian Federation, cured by endocrine surgeons. Health status after surgical correction of primary hyperparathyroidism depends on availability of screening hypercalciemia, which is still absent in our country. Another problem is a model of surgical management of primary hyperparathyroidism (frozen section, intraoperative monitoring of parathyroid hormone, gamma-detection and so on). Although minimally invasive parathyroidectomy has become the only method of treatment in many countries, it is still crucial to identify and accurately localize parathyroid glands before bilateral neck exploration surgery. The diagnostic efficacy of the various imaging techniques is still the subject of current debate. The usefulness of preoperative parathyroid imaging with both dual scintigraphy-single-photon emission computed tomography (SPECT) Tc 99m and high-resolution ultrasonography (US) was studied in 92 patients undergoing operations for primary hyperparathyroidism. The accuracy of "integrated" ultrasonography ("check-up US", "target US" after SPECT) and "intraoperative US") of parathyroid glands was 92.9%, sensitivity - 91% and positive predictive value - 94%. This study supports an algorithm of obtaining "integrated" ultrasonography as the initial and in most cases the only preoperative localization tests for patients with primary hyperparathyroidism.

  15. Improvements in diagnostic tools for early detection of psoriatic arthritis.

    PubMed

    D'Angelo, Salvatore; Palazzi, Carlo; Gilio, Michele; Leccese, Pietro; Padula, Angela; Olivieri, Ignazio

    2016-11-01

    Psoriatic arthritis (PsA) is a heterogeneous chronic inflammatory disease characterized by a wide clinical spectrum. The early diagnosis of PsA is currently a challenging topic. Areas covered: The literature was extensively reviewed for studies addressing the topic area "diagnosis of psoriatic arthritis". This review will summarize improvements in diagnostic tools, especially referral to the rheumatologist, the role of patient history and clinical examination, laboratory tests, and imaging techniques in getting an early and correct diagnosis of PsA. Expert commentary: Due to the heterogeneity of its expression, PsA may be easily either overdiagnosed or underdiagnosed. A diagnosis of PsA should be taken into account every time a patient with psoriasis or a family history of psoriasis shows peripheral arthritis, especially if oligoarticular or involving the distal interphalangeal joints, enthesitis or dactylitis. Magnetic resonance imaging and ultrasonography are useful for diagnosing PsA early, particularly when isolated enthesitis or inflammatory spinal pain occur.

  16. Ultrasonography in diagnosing chronic pancreatitis: New aspects

    PubMed Central

    Dimcevski, Georg; Erchinger, Friedemann G; Havre, Roald; Gilja, Odd Helge

    2013-01-01

    The course and outcome is poor for most patients with pancreatic diseases. Advances in pancreatic imaging are important in the detection of pancreatic diseases at early stages. Ultrasonography as a diagnostic tool has made, virtually speaking a technical revolution in medical imaging in the new millennium. It has not only become the preferred method for first line imaging, but also, increasingly to clarify the interpretation of other imaging modalities to obtain efficient clinical decision. We review ultrasonography modalities, focusing on advanced pancreatic imaging and its potential to substantially improve diagnosis of pancreatic diseases at earlier stages. In the first section, we describe scanning techniques and examination protocols. Their consequences for image quality and the ability to obtain complete and detailed visualization of the pancreas are discussed. In the second section we outline ultrasonographic characteristics of pancreatic diseases with emphasis on chronic pancreatitis. Finally, new developments in ultrasonography of the pancreas such as contrast enhanced ultrasound and elastography are enlightened. PMID:24259955

  17. Discussion of the quality control and performance testing of ultrasound diagnostic equipment

    NASA Astrophysics Data System (ADS)

    Jiang, Junjie

    2018-03-01

    In recent years, with the rapid development of ultrasonography, the application and popularization of new technology used in ultrasound equipment, the level of providing diagnostic information for doctors enhances unceasingly, which has become the indispensable diagnostic tool for medical institutions. The performance of equipment is directly related to the doctor’s diagnosis and the patient’s health, therefore, it is very important to choose a good method for quality control and performance testing.

  18. Modern management of juvenile recurrent parotitis.

    PubMed

    Capaccio, P; Sigismund, P E; Luca, N; Marchisio, P; Pignataro, L

    2012-12-01

    To evaluate modern diagnostic and therapeutic management of juvenile recurrent parotitis, and to show the benefits of operative sialoendoscopy on the basis of our experience in 14 patients and the results of others. Ultrasonography is sensitive in detecting the pathological features of juvenile recurrent parotitis. Interventional sialoendoscopy is a safe and effective method of treating the disease. In our case series, after a mean follow-up time of 30 months only 5 patients experienced recurrence of symptoms, with a mean symptom-free period of 20 months. The use of modern, minimally invasive diagnostic tools such as colour Doppler ultrasonography, magnetic resonance sialography and sialoendoscopy represents a new frontier in the management of juvenile recurrent parotitis. Operative sialoendoscopy also has the important therapeutic benefit of reducing the number of recurrences of acute episodes of parotitis, thus giving patients a better quality of life until puberty.

  19. Linear array ultrasonography to stage rectal neoplasias suitable for local treatment.

    PubMed

    Ravizza, Davide; Tamayo, Darina; Fiori, Giancarla; Trovato, Cristina; De Roberto, Giuseppe; de Leone, Annalisa; Crosta, Cristiano

    2011-08-01

    Because of the many therapeutic options available, a reliable staging is crucial for rectal neoplasia management. Adenomas and cancers limited to the submucosa without lymph node involvement may be treated locally. The aim of this study is to evaluate the diagnostic accuracy of endorectal ultrasonography in the staging of neoplasias suitable for local treatment. We considered all patients who underwent endorectal ultrasonography between 2001 and 2010. The study population consisted of 92 patients with 92 neoplasias (68 adenocarcinomas and 24 adenomas). A 5 and 7.5MHz linear array echoendoscope was used. The postoperative histopathologic result was compared with the preoperative staging defined by endorectal ultrasonography. Adenomas and cancers limited to the submucosa were considered together (pT0-1). The sensitivity, specificity, overall accuracy rate, positive predictive value, and negative predictive value of endorectal ultrasonography for pT0-1 were 86%, 95.6%, 91.3%, 94.9% and 88.7%. Those for nodal involvement were 45.4%, 95.5%, 83%, 76.9% and 84%, with 3 false positive results and 12 false negative. For combined pT0-1 and pN0, endorectal ultrasonography showed an 87.5% sensitivity, 95.9% specificity, 92% overall accuracy rate, 94.9% positive predictive value and 90.2% negative predictive value. Endorectal linear array ultrasonography is a reliable tool to detect rectal neoplasias suitable for local treatment. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  20. Diagnostic Imaging of Pregnant Women – The Role of Magnetic Resonance Imaging

    PubMed Central

    Bekiesińska-Figatowska, Monika; Romaniuk-Doroszewska, Anna; Szkudlińska-Pawlak, Sylwia; Duczkowska, Agnieszka; Mądzik, Jarosław; Szopa-Krupińska, Martyna; Maciejewski, Tomasz M.

    2017-01-01

    Summary Background Presentation of magnetic resonance imaging (MRI) findings in pregnant women in the Department of Diagnostic Imaging, Institute of Mother and Child, Warsaw, Poland. Material/Methods Forty-three symptomatic pregnant women underwent MRI between 9 and 33 weeks of gestation (mean of 23 weeks). Moreover, we included 2 pregnant women who underwent fetal MRI and had incidental abnormalities. Results In 9 cases, we excluded the suspected brain abnormalities. In 4 cases, we found unremarkable changes in the brain without clinical significance. One patient was diagnosed with multiple sclerosis, one with cortical dysplasia, one with pineal hemorrhage and one with a brain tumor. On abdominal MRI, 2 patients had normal findings, one patient had colon cancer with a hepatic metastasis, one patient had a hepatic angioma, one patient had an extraadrenal pheochromocytoma, one patient had an abscess in the iliopsoas muscle, 9 patients had myomas, two patients had ovarian simple cysts, two endometrial cysts, three dermoid cysts, one patient had sacrococcygeal teratoma, one patient had a cystadenofibroma (partial borderline tumor), one patient had an androgenic ovarian tumor and two patients had hyperreactio luteinalis. One patient was diagnosed with transient osteoporosis of the hip and one with a stress fracture of the sacral bone. Conclusions Magnetic resonance imaging is the best imaging modality for pregnant women. Although ultrasonography is the method of choice, doubtful cases as well as structures that cannot be examined with ultrasonography can be non-invasively evaluated with MRI. PMID:28507642

  1. Fundamentals of diagnostic ultrasonography.

    PubMed

    Noce, J P

    1990-01-01

    Diagnostic ultrasonography uses acoustical waves in the frequency range of 1 to 20 MHz. These waves obey Snell's law of reflection and refraction, which are rules ordinary to wave behavior. In ultrasound, the analogy to momentum is acoustic impedance. The acoustic impedance, Z, is equal to the density, p, times velocity, v. The ultrasound transducer converts electrical energy into ultrasound energy and vice versa. The transducer usually consists of a piezoelectric crystal composed of such ceramic materials as barium titanate, lead titanate, zirconate, or lead metaniobate. Five basic ultrasonic scanning modes play the major roles in clinical applications. A-mode, or amplitude-mode, scanning measures the tissue discontinuity along the scan axis. B-mode scanning produces a two-dimensional image of the tissue under study by combining A-mode signals from various directions through mechanical transducer scanning. M-mode, or time motion scanning, is an extension of the A-mode approach in which a single stationary transducer is used. The depth of the echo is displayed on the vertical axis; the brightness of the oscilloscope display is modulated by the echo amplitude. Real-time scanning, or rapid B-scanning, techniques provide continuous data acquisition at a rate sufficient to give the impression of the instantaneous motion of moving structures. Doppler scanning relies on the presence of motion. The Doppler effect occurs when there is relative motion between the source of sound and the receiver of the sound, causing a change in the detected frequency of the sound source.

  2. Electrophysiological examination and high frequency ultrasonography for diagnosis of radial nerve torsion and compression

    PubMed Central

    Shi, Miao; Qi, Hengtao; Ding, Hongyu; Chen, Feng; Xin, Zhaoqin; Zhao, Qinghua; Guan, Shibing; Shi, Hao

    2018-01-01

    Abstract This study aims to evaluate the value of electrophysiological examination and high frequency ultrasonography in the differential diagnosis of radial nerve torsion and radial nerve compression. Patients with radial nerve torsion (n = 14) and radial nerve compression (n = 14) were enrolled. The results of neurophysiological and high frequency ultrasonography were compared. Electrophysiological examination and high-frequency ultrasonography had a high diagnostic rate for both diseases with consistent results. Of the 28 patients, 23 were positive for electrophysiological examination, showing decreased amplitude and decreased conduction velocity of radial nerve; however, electrophysiological examination cannot distinguish torsion from compression. A total of 27 cases showed positive in ultrasound examinations among all 28 cases. On ultrasound images, the nerve was thinned at torsion site whereas thickened at the distal ends of torsion. The diameter and cross-sectional area of torsion or compression determined the nerve damage, and ultrasound could locate the nerve injury site and measure the length of the nerve. Electrophysiological examination and high-frequency ultrasonography can diagnose radial neuropathy, with electrophysiological examination reflecting the neurological function, and high-frequency ultrasound differentiating nerve torsion from compression. PMID:29480857

  3. Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis.

    PubMed

    Alrajab, Saadah; Youssef, Asser M; Akkus, Nuri I; Caldito, Gloria

    2013-09-23

    Ultrasonography is being increasingly utilized in acute care settings with expanding applications. Pneumothorax evaluation by ultrasonography is a fast, safe, easy and inexpensive alternative to chest radiographs. In this review, we provide a comprehensive analysis of the current literature comparing ultrasonography and chest radiography for the diagnosis of pneumothorax. We searched English-language articles in MEDLINE, EMBASE and Cochrane Library dealing with both ultrasonography and chest radiography for diagnosis of pneumothorax. In eligible studies that met strict inclusion criteria, we conducted a meta-analysis to evaluate the diagnostic accuracy of pleural ultrasonography in comparison with chest radiography for the diagnosis of pneumothorax. We reviewed 601 articles and selected 25 original research articles for detailed review. Only 13 articles met all of our inclusion criteria and were included in the final analysis. One study used lung sliding sign alone, 12 studies used lung sliding and comet tail signs, and 6 studies searched for lung point in addition to the other two signs. Ultrasonography had a pooled sensitivity of 78.6% (95% CI, 68.1 to 98.1) and a specificity of 98.4% (95% CI, 97.3 to 99.5). Chest radiography had a pooled sensitivity of 39.8% (95% CI, 29.4 to 50.3) and a specificity of 99.3% (95% CI, 98.4 to 100). Our meta-regression and subgroup analyses indicate that consecutive sampling of patients compared to convenience sampling provided higher sensitivity results for both ultrasonography and chest radiography. Consecutive versus nonconsecutive sampling and trauma versus nontrauma settings were significant sources of heterogeneity. In addition, subgroup analysis showed significant variations related to operator and type of probe used. Our study indicates that ultrasonography is more accurate than chest radiography for detection of pneumothorax. The results support the previous investigations in this field, add new valuable information obtained from subgroup analysis, and provide accurate estimates for the performance parameters of both bedside ultrasonography and chest radiography for pneumothorax evaluation.

  4. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder.

    PubMed

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-11-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound for inter-reader agreements were 0.717, 0.794 and 0.914. Three-dimensional contrast-enhanced ultrasound imaging, with contrast-enhanced spatial visualization is clinical useful for differentiating invasive and noninvasive neoplasms of urinary bladder objectively. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Point-of-Care Ultrasonography in Emergency and Critical Care Medicine.

    PubMed

    Chen, Leon; Malek, Tony

    To stabilize critically ill patients, emergency and critical care medicine providers often require rapid diagnosis and intervention. The demand for a safe, timely diagnostic device, alongside technological innovation, led to the advent of point-of-care ultrasonography (POCUS). POCUS allows the provider to gain invaluable clinical information with a high level of accuracy, leading to better clinical decision-making and improvements in patient safety. We have outlined the history of POCUS adaptation in emergency and critical care medicine and various clinical applications of POCUS described in literature.

  6. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis.

    PubMed

    Martins, N; Polido-Pereira, J; Rodrigues, A M; Soares, F; Batista, P; Pereira da Silva, J A

    2016-01-01

    Giant Cell Arteritis (GCA) is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS) is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  7. Role of ultrasonography in the management of twin gestation.

    PubMed

    Smith, Jessica; Treadwell, Marjorie C; Berman, Deborah R

    2018-06-01

    Twins represent 1%-2% of all pregnancies, yet continue to account for a disproportionate share of neonatal adverse events including neonatal intensive care admission, morbidity, and mortality. Ultrasonography is central to the proper diagnosis of the type of twinning. Ideally, ultrasonography is performed before 14 weeks of gestation to determine chorionicity and amnionicity. Correct identification of the chorionicity in a twin pregnancy facilitates proper counseling and management of the gestation, including ultrasonography follow-up. Herein, the different types of twinning are reviewed, together with the implications for ultrasonography monitoring of each specific type of twin gestation. © 2018 International Federation of Gynecology and Obstetrics.

  8. Medical Imaging.

    ERIC Educational Resources Information Center

    Jaffe, C. Carl

    1982-01-01

    Describes principle imaging techniques, their applications, and their limitations in terms of diagnostic capability and possible adverse biological effects. Techniques include film radiography, computed tomography, nuclear medicine, positron emission tomography (PET), ultrasonography, nuclear magnetic resonance, and digital radiography. PET has…

  9. Application of Ultrasonography and Radiography in Detection of Hemothorax; a Systematic Review and Meta-Analysis

    PubMed Central

    Rahimi-Movaghar, Vafa; Yousefifard, Mahmoud; Ghelichkhani, Parisa; Baikpour, Masoud; Tafakhori, Abbas; Asady, Hadi; Faridaalaee, Gholamreza; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    Introduction: Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography and radiography in detection of hemothorax through a systematic review and meta-analysis. Methods: Two independent reviewers performed an extended systematic search in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Data were extract and quality of the relevant studies were assessed. The number of true positive, false positive, true negative and false negative cases were extracted and screening performance characteristics of two imaging techniques were calculated using a mixed-effects binary regression model. Results: Data from 12 studies were extracted and included in the meta-analysis (7361 patients, 77.1% male). Pooled sensitivity and specificity of ultrasonography in detection of hemothorax were 0.67 (95% CI: 0.41-0.86; I2= 68.38, p<0.001) and 0.99 (95% CI: 0.95-1.0; I2= 88.16, p<0.001), respectively. These measures for radiography were 0.54 (95% CI: 0.33-0.75; I2= 92.85, p<0.001) and 0.99 (95% CI: 0.94-1.0; I2= 99.22, p<0.001), respectively. Subgroup analysis found operator of the ultrasonography device, frequency of the transducer and sample size to be important sources of heterogeneity of included studies. Conclusion: The results of this study showed that although the sensitivity of ultrasonography in detection of hemothorax is relatively higher than radiography, but it is still at a moderate level (0.67%). The specificity of both imaging modalities were found to be at an excellent level in this regard. The screening characteristics of ultrasonography was found to be influenced of the operator and frequency of transducer PMID:27299139

  10. Transvaginal duplex ultrasonography appears to be the gold standard investigation for the haemodynamic evaluation of pelvic venous reflux in the ovarian and internal iliac veins in women.

    PubMed

    Whiteley, M S; Dos Santos, S J; Harrison, C C; Holdstock, J M; Lopez, A J

    2015-12-01

    To assess the suitability of transvaginal duplex ultrasonography to identify pathological reflux in the ovarian and internal iliac veins in women. A retrospective study of patients treated in 2011 and 2012 was performed in a specialised vein clinic. Diagnostic transvaginal duplex ultrasonography in women presenting with symptoms or signs of pelvic vein reflux were compared with the outcomes of treatment from pelvic vein embolisation. A repeat transvaginal duplex ultrasonography was performed 6 weeks later by a blinded observer and any residual reflux was identified. Results from 100 sequential patients were analysed. Mean age 44.2 years (32-69) with mode average parity of 3 (0-5 deliveries). Pre-treatment, 289/400 veins were refluxing (ovarian - 29 right, 81 left; internal iliac - 93 right, 86 left). Coil embolisation was successful in 86/100 patients and failed partially in 14/100 - 5 due to failure to cannulate the target vein. One false-positive diagnosis was made. Currently there is no accepted gold standard for pelvic vein incompetence. Comparing transvaginal duplex ultrasonography with the outcome from selectively treating the veins identified as having pathological reflux with coil embolisation, there were no false-negative diagnoses and only one false-positive. This study suggests that transvaginal duplex ultrasonography could be the gold standard in assessing pelvic vein reflux. © The Author(s) 2014.

  11. Carcinoma of the pancreatic head and periampullary region. Tumor staging with laparoscopy and laparoscopic ultrasonography.

    PubMed Central

    John, T G; Greig, J D; Carter, D C; Garden, O J

    1995-01-01

    OBJECTIVE: The authors performed a prospective evaluation of staging laparoscopy with laparoscopic ultrasonography in predicting surgical resectability in patients with carcinomas of the pancreatic head and periampullary region. SUMMARY BACKGROUND DATA: Pancreatic resection with curative intent is possible in a select minority of patients who have carcinomas of the pancreatic head and periampullary region. Patient selection is important to plan appropriate therapy and avoid unnecessary laparotomy in patients with unresectable disease. Laparoscopic ultrasonography is a novel technique that combines the proven benefits of staging laparoscopy with high resolution intraoperative ultrasound of the liver and pancreas, but which has yet to be evaluated critically in the staging of pancreatic malignancy. METHODS: A cohort of 40 consecutive patients referred to a tertiary referral center and with a diagnosis of potentially resectable pancreatic or periampullary cancer underwent staging laparoscopy with laparoscopic ultrasonography. The diagnostic accuracy of staging laparoscopy alone and in conjunction with laparoscopic ultrasonography was evaluated in predicting tumor resectability (absence of peritoneal or liver metastases; absence of malignant regional lymphadenopathy; tumor confined to pancreatic head or periampullary region). RESULTS: "Occult" metastatic lesions were demonstrated by staging laparoscopy in 14 patients (35%). Laparoscopic ultrasonography demonstrated factors confirming unresectable tumor in 23 patients (59%), provided staging information in addition to that of laparoscopy alone in 20 patients (53%), and changed the decision regarding tumor resectability in 10 patients (25%). Staging laparoscopy with laparoscopic ultrasonography was more specific and accurate in predicting tumor resectability than laparoscopy alone (88% and 89% versus 50% and 65%, respectively). CONCLUSIONS: Staging laparoscopy is indispensable in the detection of "occult" intra-abdominal metastases. Laparoscopic ultrasonography improves the accuracy of laparoscopic staging in patients with potentially resectable pancreatic and periampullary carcinomas. Images Figure 1. Figure 2. Figure 3. Figure 4. PMID:7857143

  12. Diagnostic accuracy of transabdominal ultrasonography for gallbladder polyps: systematic review.

    PubMed

    Martin, Erin; Gill, Richdeep; Debru, Estifanos

    2018-06-01

    Previous research has shown variable but generally poor accuracy of transabdominal ultrasonography in the diagnosis of gallbladder polyps. We performed a systematic review of the literature with the aim of helping surgeons interpret and apply these findings in the preoperative assessment and counselling of their patients. We searched PubMed, MEDLINE and the Cochrane database using the keywords "gallbladder," "polyp," "ultrasound," "pathology" and "diagnosis" for English-language articles published after 1990 with the full-text article available through our institutional subscriptions. Polyps were defined as immobile features that on transabdominal ultrasonography appear to arise from the mucosa and that lack an acoustic shadow, and pseudopolyps were defined as features such as inflammation, hyperplasia, cholesterolosis and adenomyomatosis that convey no risk of malignant transformation. The search returned 1816 articles, which were narrowed down to 14 primary sources involving 15 497 (range 23-13 703) patients who had preoperative transabdominal ultrasonography, underwent cholecystectomy and had postoperative pathology results available. Among the 1259 patients in whom a gallbladder polyp was diagnosed on ultrasonography, 188 polyps were confirmed as true polyps on pathologic examination, and 81 of these were found to be malignant. Of the 14 238 patients for whom a polyp was not seen on ultrasonography, 38 had a true polyp on pathologic examination, none of which were malignant. For true gallbladder polyps, transabdominal ultrasonography had a sensitivity of 83.1%, specificity of 96.3%, positive predictive value of 14.9% (7.0% for malignant polyps) and negative predictive value of 99.7%. Transabdominal ultrasonography has a high false-positive rate (85.1%) for the diagnosis of gallbladder polyps. Further study of alternative imaging modalities and reevaluation of existing management guidelines are warranted.

  13. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    PubMed

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  14. Diagnostic imaging and radiation exposure in inflammatory bowel disease.

    PubMed

    Zakeri, Nekisa; Pollok, Richard C G

    2016-02-21

    Diagnostic imaging plays a key role in the diagnosis and management of inflammatory bowel disease (IBD). However due to the relapsing nature of IBD, there is growing concern that IBD patients may be exposed to potentially harmful cumulative levels of ionising radiation in their lifetime, increasing malignant potential in a population already at risk. In this review we explore the proportion of IBD patients exposed to high cumulative radiation doses, the risk factors associated with higher radiation exposures, and we compare conventional diagnostic imaging with newer radiation-free imaging techniques used in the evaluation of patients with IBD. While computed tomography (CT) performs well as an imaging modality for IBD, the effective radiation dose is considerably higher than other abdominal imaging modalities. It is increasingly recognised that CT imaging remains responsible for the majority of diagnostic medical radiation to which IBD patients are exposed. Magnetic resonance imaging (MRI) and small intestine contrast enhanced ultrasonography (SICUS) have now emerged as suitable radiation-free alternatives to CT imaging, with comparable diagnostic accuracy. The routine use of MRI and SICUS for the clinical evaluation of patients with known or suspected small bowel Crohn's disease is to be encouraged wherever possible. More provision is needed for out-of-hours radiation-free imaging modalities to reduce the need for CT.

  15. Diagnostic imaging and radiation exposure in inflammatory bowel disease

    PubMed Central

    Zakeri, Nekisa; Pollok, Richard CG

    2016-01-01

    Diagnostic imaging plays a key role in the diagnosis and management of inflammatory bowel disease (IBD). However due to the relapsing nature of IBD, there is growing concern that IBD patients may be exposed to potentially harmful cumulative levels of ionising radiation in their lifetime, increasing malignant potential in a population already at risk. In this review we explore the proportion of IBD patients exposed to high cumulative radiation doses, the risk factors associated with higher radiation exposures, and we compare conventional diagnostic imaging with newer radiation-free imaging techniques used in the evaluation of patients with IBD. While computed tomography (CT) performs well as an imaging modality for IBD, the effective radiation dose is considerably higher than other abdominal imaging modalities. It is increasingly recognised that CT imaging remains responsible for the majority of diagnostic medical radiation to which IBD patients are exposed. Magnetic resonance imaging (MRI) and small intestine contrast enhanced ultrasonography (SICUS) have now emerged as suitable radiation-free alternatives to CT imaging, with comparable diagnostic accuracy. The routine use of MRI and SICUS for the clinical evaluation of patients with known or suspected small bowel Crohn’s disease is to be encouraged wherever possible. More provision is needed for out-of-hours radiation-free imaging modalities to reduce the need for CT. PMID:26900282

  16. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    PubMed

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression ultrasonographic result. One patient with a negative Department of Radiology ultrasonographic result was found to have decreased compression of the popliteal vein on ED compression ultrasonography, giving a single false-positive result, yet repeated ultrasonography by the Department of Radiology 1 week later showed a popliteal deep venous thrombosis. The sensitivity and specificity of ED 2-point compression ultrasonography for deep venous thrombosis were 100% (95% confidence interval 92% to 100%) and 99% (95% confidence interval 96% to 100%), respectively. Emergency physician-performed 2-point compression ultrasonography of the lower extremity with a portable vascular ultrasonographic machine, conducted in the ED by this physician group and in this patient sample, accurately identified the presence and absence of proximal lower extremity deep venous thrombosis. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  17. Use of high-frequency ultrasonography for evaluation of skin thickness in relation to hydration status and fluid distribution at various cutaneous sites in dogs.

    PubMed

    Diana, Alessia; Guglielmini, Carlo; Fracassi, Federico; Pietra, Marco; Balletti, Erika; Cipone, Mario

    2008-09-01

    To assess the usefulness of high-frequency diagnostic ultrasonography for evaluation of changes of skin thickness in relation to hydration status and fluid distribution at various cutaneous sites in dogs. 10 clinically normal adult dogs (6 males and 4 females) of various breeds. Ultrasonographic examination of the skin was performed before and after hydration via IV administration of an isotonic crystalloid solution (30 mL/kg/h for 30 minutes). A 13-MHz linear-array transducer was used to obtain series of ultrasonographic images at 4 different cutaneous sites (the frontal, sacral, flank, and metatarsal regions). Weight and various clinicopathologic variables (PCV; serum osmolality; and serum total protein, albumin, and sodium concentrations) were determined before and after the infusion. These variables and ultrasonographic measurements of skin thickness before and after hydration were compared. Among the 10 dogs, mean preinfusion skin thickness ranged from 2,211 microm (metatarsal region) to 3,249 microm (sacral region). Compared with preinfusion values, weight was significantly increased, whereas PCV; serum osmolality; and serum total protein, albumin, and sodium concentrations were significantly decreased after infusion. After infusion, dermal echogenicity decreased and skin thickness increased significantly by 21%, 14%, 15%, and 13% in the frontal, sacral, flank, and metatarsal regions, respectively. Cutaneous site and hydration were correlated with cutaneous characteristics and skin thickness determined by use of high-frequency ultrasonography in dogs. Thus, diagnostic ultrasonography may be a useful tool for the noninvasive evaluation of skin hydration in healthy dogs and in dogs with skin edema.

  18. Efficacy of High Frequency Ultrasound in Localization and Characterization of Orbital Lesions

    PubMed Central

    Gurushankar, G; Bhimarao; Kadakola, Bindushree

    2015-01-01

    Background The complicated anatomy of orbit and the wide spectrum of pathological conditions present a formidable challenge for early diagnosis, which is critical for management. Ultrasonography provides a detailed cross sectional anatomy of the entire globe with excellent topographic visualization and real time display of the moving organ. Objectives of the study To evaluate the efficacy of high frequency Ultrasound in localization of orbital diseases and to characterize various orbital pathologies sonologically. Materials and Methods Hundred eyes of 85 patients were examined with ultrasound using linear high frequency probe (5 to 17 MHz) of PHILPS IU22 ultrasound system. Sonological diagnosis was made based on location, acoustic characteristics, kinetic properties and Doppler flow dynamics. Final diagnosis was made based on clinical & laboratory findings/higher cross-sectional imaging/surgery & histopathology (as applicable). Diagnostic accuracy of ultrasonography was evaluated and compared with final diagnosis. Results The distinction between ocular and extraocular pathologies was made in 100% of cases. The overall sensitivity, specificity, NPV and accuracy of ultrasonography were 94.2%, 98.8%, 92.2% & 94.9% respectively for diagnosis of ocular pathologies and 94.2%, 99.2%, 95.9% & 95.2% respectively for extra ocular pathologies. Conclusion Ultrasonography is a readily available, simple, cost effective, non ionizing and non invasive modality with overall high diagnostic accuracy in localising and characterising orbital pathologies. It has higher spatial and temporal resolution compared to CT/MRI. However, CT/MRI may be indicated in certain cases for the evaluation of calcifications, bony involvement, extension to adjacent structures and intracranial extension. PMID:26500977

  19. High-resolution ultrasonography in assessment of nail-related disorders.

    PubMed

    Singh, R; Bryson, D; Singh, H P; Jeyapalan, K; Dias, J J

    2012-09-01

    Disorders of the nail can pose a diagnostic challenge, and non-invasive imaging is frequently required to clarify diagnosis and delineate anatomy pre-operatively. We explored the use of high-resolution ultrasonography in the assessment of patients with nail disorders attending orthopaedic hand clinics. A search of a university teaching hospital musculoskeletal radiology database identified 36 patients (mean age 54.2 years) where ultrasonography was used to assess nail-related disorders between April 2003 and January 2007. Clinical, surgical and histological findings were correlated in these cases with ultrasound reports. Ultrasound findings correlated with the provisional diagnosis in 20 (61%) of 33 patients and provided a diagnosis in 3 patients where a provisional diagnosis was unavailable. In 7 of the 13 cases where the clinical diagnosis differed from ultrasound findings, a lump originally diagnosed as cystic in origin was shown to be solid on ultrasound. Different nail pathologies showed different characteristics on ultrasonography, including differences in vascularity, echogenicity, changes in nail structure/shape and extension into the nail bed, matrix, fold or evidence of bony erosion. The ultrasound findings correlated with histological analysis and intra-operative assessment in 10 of 15 patients who underwent operative treatment. Ultrasound provides important information on the anatomy of the nail apparatus and can differentiate solid and cystic lesions. It can be used as a diagnostic tool and can therefore help in pre-operative planning of nail-related disorders. In our series ultrasound supported or improved upon the clinical diagnosis in 31 (86%) out of the 36 patients presenting with nail-related disorders.

  20. The utility and yield of endoscopic ultrasonography for suspected choledocholithiasis in common gastroenterology practice.

    PubMed

    Quispel, Rutger; van Driel, Lydi M W J; Veldt, Bart J; van Haard, Paul M M; Bruno, Marco J

    2016-12-01

    Endoscopic ultrasonography (EUS) is an established diagnostic modality for diagnosing common bile duct (CBD) stones. Its use has led to a reduction in the number of endoscopic retrograde cholangiopancreatography (ERCP) procedures performed for suspected choledocholithiasis. We aimed to explore the role of EUS in detecting CBD stones and/or sludge in common gastroenterology practice. We reviewed case records of 268 consecutive patients who underwent (EUS) procedures performed to confirm or rule out the presence of CBD stones and/or sludge between November 2006 and January 2011 in the Reinier de Graaf Hospital, Delft, The Netherlands, which is a nonacademic community hospital. On the basis of EUS findings, 169 of 268 (63%) patients did not undergo ERCP and were therefore not exposed to its risk of complications. Patients with positive findings on EUS (n=99) all underwent ERCP and endoscopic sphincterotomy. Only 57 of 99 (58%) had positive findings at ERCP. The main contributing factors to this finding seem to be time interval between EUS and ERCP and the type of CBD content (i.e. sludge, one CBD stone or more than one CBD stone) described. In our common gastroenterology practice, EUS plays an important role in selecting patients suspected to have CBD stones or sludge for ERCP. Much is to be learned about the probability of spontaneous passage of CBD stones and sludge into the duodenum.

  1. Diagnosis of a sigmoid volvulus in pregnancy: ultrasonography and magnetic resonance imaging findings

    PubMed Central

    Palmucci, Stefano; Lanza, Maria Letizia; Gulino, Fabrizio; Scilletta, Beniamino; Ettorre, Giovanni Carlo

    2014-01-01

    Sigmoid volvulus complicating pregnancy is a rare, non-obstetric cause of abdominal pain that requires prompt surgical intervention (decompression) to avoid intestinal ischemia and perforation. We report the case of a 31-week pregnant woman with abdominal pain and subsequent development of constipation. Preoperative diagnosis was achieved using magnetic resonance imaging and ultrasonography: the large bowel distension and a typical whirl sign - near a sigmoid colon transition point - suggested the diagnosis of sigmoid volvulus. The decision to refer the patient for emergency laparotomy was adopted without any ionizing radiation exposure, and the pre-operative diagnosis was confirmed after surgery. Imaging features of sigmoid volvulus and differential diagnosis from other non-obstetric abdominal emergencies in pregnancy are discussed in our report, with special emphasis on the diagnostic capabilities of ultrasonography and magnetic resonance imaging. PMID:24967020

  2. Diagnosis of a sigmoid volvulus in pregnancy: ultrasonography and magnetic resonance imaging findings.

    PubMed

    Palmucci, Stefano; Lanza, Maria Letizia; Gulino, Fabrizio; Scilletta, Beniamino; Ettorre, Giovanni Carlo

    2014-02-01

    Sigmoid volvulus complicating pregnancy is a rare, non-obstetric cause of abdominal pain that requires prompt surgical intervention (decompression) to avoid intestinal ischemia and perforation. We report the case of a 31-week pregnant woman with abdominal pain and subsequent development of constipation. Preoperative diagnosis was achieved using magnetic resonance imaging and ultrasonography: the large bowel distension and a typical whirl sign - near a sigmoid colon transition point - suggested the diagnosis of sigmoid volvulus. The decision to refer the patient for emergency laparotomy was adopted without any ionizing radiation exposure, and the pre-operative diagnosis was confirmed after surgery. Imaging features of sigmoid volvulus and differential diagnosis from other non-obstetric abdominal emergencies in pregnancy are discussed in our report, with special emphasis on the diagnostic capabilities of ultrasonography and magnetic resonance imaging.

  3. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    PubMed

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  4. Does ultrasonography accurately diagnose acute cholecystitis? Improving diagnostic accuracy based on a review at a regional hospital

    PubMed Central

    Hwang, Hamish; Marsh, Ian; Doyle, Jason

    2014-01-01

    Background Acute cholecystitis is one of the most common diseases requiring emergency surgery. Ultrasonography is an accurate test for cholelithiasis but has a high false-negative rate for acute cholecystitis. The Murphy sign and laboratory tests performed independently are also not particularly accurate. This study was designed to review the accuracy of ultrasonography for diagnosing acute cholecystitis in a regional hospital. Methods We studied all emergency cholecystectomies performed over a 1-year period. All imaging studies were reviewed by a single radiologist, and all pathology was reviewed by a single pathologist. The reviewers were blinded to each other’s results. Results A total of 107 patients required an emergency cholecystectomy in the study period; 83 of them underwent ultrasonography. Interradiologist agreement was 92% for ultrasonography. For cholelithiasis, ultrasonography had 100% sensitivity, 18% specificity, 81% positive predictive value (PPV) and 100% negative predictive value (NPV). For acute cholecystitis, it had 54% sensitivity, 81% specificity, 85% PPV and 47% NPV. All patients had chronic cholecystitis and 67% had acute cholecystitis on histology. When combined with positive Murphy sign and elevated neutrophil count, an ultrasound showing cholelithiasis or acute cholecystitis yielded a sensitivity of 74%, specificity of 62%, PPV of 80% and NPV of 53% for the diagnosis of acute cholecystitis. Conclusion Ultrasonography alone has a high rate of false-negative studies for acute cholecystitis. However, a higher rate of accurate diagnosis can be achieved using a triad of positive Murphy sign, elevated neutrophil count and an ultrasound showing cholelithiasis or cholecystitis. PMID:24869607

  5. Postoperative ultrasonography of the musculoskeletal system.

    PubMed

    Chun, Kyung Ah; Cho, Kil-Ho

    2015-07-01

    Ultrasonography of the postoperative musculoskeletal system plays an important role in the accurate diagnosis of abnormal lesions in the bone and soft tissues. Ultrasonography is a fast and reliable method with no harmful irradiation for the evaluation of postoperative musculoskeletal complications. In particular, it is not affected by the excessive metal artifacts that appear on computed tomography or magnetic resonance imaging. Another benefit of ultrasonography is its capability to dynamically assess the pathologic movement in joints, muscles, or tendons. This article discusses the frequent applications of musculoskeletal ultrasonography in various postoperative situations including those involving the soft tissues around the metal hardware, arthroplasty, postoperative tendons, recurrent soft tissue tumors, bone unions, and amputation surgery.

  6. A review of ultrasonographic methods for the assessment of the anterior cruciate ligament in patients with knee instability – diagnostics using a posterior approach

    PubMed Central

    Kielar, Maciej

    2016-01-01

    Aim The purpose of the study was to improve the ultrasonographic assessment of the anterior cruciate ligament by an inclusion of a dynamic element. The proposed functional modification aims to restore normal posterior cruciate ligament tension, which is associated with a visible change in the ligament shape. This method reduces the risk of an error resulting from subjectively assessing the shape of the posterior cruciate ligament. It should be also emphasized that the method combined with other ultrasound anterior cruciate ligament assessment techniques helps increase diagnostic accuracy. Methods Ultrasonography is used as an adjunctive technique in the diagnosis of anterior cruciate ligament injury. The paper presents a sonographic technique for the assessment of suspected anterior cruciate ligament insufficiency supplemented by the use of a dynamic examination. This technique can be recommended as an additional procedure in routine ultrasound diagnostics of anterior cruciate ligament injuries. Results Supplementing routine ultrasonography with the dynamic assessment of posterior cruciate ligament shape changes in patients with suspected anterior cruciate ligament injury reduces the risk of subjective errors and increases diagnostic accuracy. This is important especially in cases of minor anterior knee instability and bilateral anterior knee instability. Conclusions An assessment of changes in posterior cruciate ligament using a dynamic ultrasound examination effectively complements routine sonographic diagnostic techniques for anterior cruciate ligament insufficiency. PMID:27679732

  7. Ultrasonography of ovarian masses using a pattern recognition approach

    PubMed Central

    Jung, Sung Il

    2015-01-01

    As a primary imaging modality, ultrasonography (US) can provide diagnostic information for evaluating ovarian masses. Using a pattern recognition approach through gray-scale transvaginal US, ovarian masses can be diagnosed with high specificity and sensitivity. Doppler US may allow ovarian masses to be diagnosed as benign or malignant with even greater confidence. In order to differentiate benign and malignant ovarian masses, it is necessary to categorize ovarian masses into unilocular cyst, unilocular solid cyst, multilocular cyst, multilocular solid cyst, and solid tumor, and then to detect typical US features that demonstrate malignancy based on pattern recognition approach. PMID:25797108

  8. [Double localization of pancreatic insulinoma. Diagnostic and therapeutic difficulties].

    PubMed

    Ungureanu, C D; David, L; Braşoveanu, V; Herlea, V; Coculescu, M; Popescu, I

    2005-01-01

    Insulinomas are the most common cause of hypoglycemia resulting from endogenous hyperinsulinism. Because most of insulinomas are less than 2 cm in size and rarely they not may be visible by CT scan or transabdominal ultrasonography. Intraoperative ultrasonography may be a solution. Although as surgical method is preferred enucleation because operative time is shorter and easier and the low frequency postoperative complications, pancreaticoduodenectomy Whipple is indicated in selected cases. We report a case of double insulinoma located in the head of the pancreas in which the diagnosis and surgical treatment presented difficulties which determined a particular clinical evolution.

  9. How to manage thyroid nodules with two consecutive non-diagnostic results on ultrasonography-guided fine-needle aspiration.

    PubMed

    Moon, Hee Jung; Kwak, Jin Young; Choi, Yoon Seong; Kim, Eun-Kyung

    2012-03-01

    The aim of this study was to investigate the factors for considering surgery on thyroid nodules that had non-diagnostic results on two consecutive cytology examinations. A total of 104 thyroid nodules with two consecutive non-diagnostic cytology examinations in 104 patients were investigated. Nodules with one or more suspicious ultrasonography (US) features of marked hypoechogenicity, a not well defined margin, microcalcifications, or a taller-than-wide shape were assessed as sonographically suspicious. Those without any suspicious features were assessed as sonographically benign. The clinicopathologic characteristics of patients and US features of the nodules were compared according to malignancy and benignity. The odds ratio for predicting malignancy was calculated. Altogether, 12 nodules were malignant, and 92 were benign. Age, sex, nodule size, and solidness were not associated with malignancy (P = 0.73, 0.92, 0.48, and 0.73, respectively). The malignancy rate of sonographically suspicious nodules was 25.7%, higher than the 4.3% of sonographically benign nodules (P = 0.002). The odds ratio of sonographically suspicious nodules for predicting malignancy was 16.01 (95% confidence interval 2.36-108.54, P = 0.005). Based on sonographic features, surgery can be performed selectively on nodules with two consecutive non-diagnostic cytology results.

  10. Diagnostic accuracy of ultrasonography, MRI and MR arthrography in the characterisation of rotator cuff disorders: a systematic review and meta-analysis

    PubMed Central

    Roy, Jean-Sébastien; Braën, Caroline; Leblond, Jean; Desmeules, François; Dionne, Clermont E; MacDermid, Joy C; Bureau, Nathalie J; Frémont, Pierre

    2015-01-01

    Background Different diagnostic imaging modalities, such as ultrasonography (US), MRI, MR arthrography (MRA) are commonly used for the characterisation of rotator cuff (RC) disorders. Since the most recent systematic reviews on medical imaging, multiple diagnostic studies have been published, most using more advanced technological characteristics. The first objective was to perform a meta-analysis on the diagnostic accuracy of medical imaging for characterisation of RC disorders. Since US is used at the point of care in environments such as sports medicine, a secondary analysis assessed accuracy by radiologists and non-radiologists. Methods A systematic search in three databases was conducted. Two raters performed data extraction and evaluation of risk of bias independently, and agreement was achieved by consensus. Hierarchical summary receiver-operating characteristic package was used to calculate pooled estimates of included diagnostic studies. Results Diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears was high with overall estimates of sensitivity and specificity over 0.90. As for partial RC tears and tendinopathy, overall estimates of specificity were also high (>0.90), while sensitivity was lower (0.67–0.83). Diagnostic accuracy of US was similar whether a trained radiologist, sonographer or orthopaedist performed it. Conclusions Our results show the diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears. Since full thickness tear constitutes a key consideration for surgical repair, this is an important characteristic when selecting an imaging modality for RC disorder. When considering accuracy, cost, and safety, US is the best option. PMID:25677796

  11. Utility of Endoanal Ultrasonography in Assessment of Primary and Recurrent Anal Fistulas and for Detection of Associated Anal Sphincter Defects.

    PubMed

    Emile, Sameh Hany; Magdy, Alaa; Youssef, Mohamed; Thabet, Waleed; Abdelnaby, Mahmoud; Omar, Waleed; Khafagy, Wael

    2017-11-01

    Tridimensional endoanal ultrasonography (3D-EAUS) has been used for the assessment of various anorectal lesions. Previous studies have reported good accuracy of 3D-EAUS in preoperative assessment of fistula-in-ano (FIA). This study aimed to assess the diagnostic utility of 3D-EAUS in preoperative evaluation of primary and recurrent FIA and its role in detection of associated anal sphincter (AS) defects. Prospectively collected data of patients with FIA who were investigated with 3D-EAUS were reviewed. The findings of EAUS were compared with the intraoperative findings, the reference standard, to find the degree of agreement regarding the position of the internal opening (IO) and primary tract (PT), and presence of secondary tracts using kappa (k) coefficient test. A subgroup analysis was performed to compare the accuracy and sensitivity of EAUS for primary and recurrent FIA. Of the patients, 131 were included to the study. EAUS had an overall accuracy of 87, 88.5, and 89.5% in detection of IO, PT, and AS defects, respectively. There was very good concordance between the findings of EAUS and intraoperative findings for the investigated parameters (kappa = 0.748, 0.83, 0.935), respectively. Accuracy and sensitivity of EAUS in recurrent FIA were insignificantly lower than primary cases. EAUS detected occult AS defects in 5.3% of the patients studied. The diagnostic utility of 3D-EAUS was comparable in primary and recurrent FIA. 3D-EAUS was able to detect symptomatic and occult AS defects with higher accuracy than clinical examination.

  12. Ultrasound and other imaging technologies in the intensive care unit.

    PubMed

    Lee, S Y; Frankel, H L

    2000-06-01

    As technology advances, more imaging and procedures are performed at the bedside on critically ill patients in ICUs, thereby eliminating the risks of transporting patients. These imaging techniques can serve as diagnostic and therapeutic tools in treating the acute and chronic consequences of injured, critically ill patients. One area of growth is ultrasonography. Critical care applications of ultrasonography are expanding, and the learning curve of surgeons and intensivists performing some of these studies is improving. Ultrasonography can supplement physical examination and provide useful "real-time" information on nearly every body cavity. Other imaging technology is also available in a portable form, enabling imaging directly at the bedside. Images are now becoming readily and easily available with the advancement of teleradiology. Some of the imaging modalities are still in development, and their clinical effectiveness is being studied. In the future, more uses of these various imaging technologies may become evident and cost-effective.

  13. Ultrasonography in neuralgic amyotrophy: Sensitivity, spectrum of findings, and clinical correlations.

    PubMed

    ArÁnyi, Zsuzsanna; Csillik, Anita; DéVay, Katalin; Rosero, Maja; Barsi, PéTer; BÖhm, Josef; Schelle, Thomas

    2017-12-01

    The aim of this study was to assess the value of ultrasonography in neuralgic amyotrophy. Fifty-three patients with 70 affected nerves were examined with high-resolution ultrasound. The most commonly affected nerve was the anterior interosseous (23%). Ultrasonographic abnormalities in the affected nerves, rather than in the brachial plexus, were observed, with an overall sensitivity of 74%. Findings included the swelling of the nerve/fascicle with or without incomplete/complete constriction and rotational phenomena (nerve torsion and fascicular entwinement). A significant difference was found among the categories of ultrasonographic findings with respect to clinical outcome (P = 0.01). In nerves with complete constriction and rotational phenomena, reinnervation was absent or negligible, indicating surgery was warranted. Ultrasonography may be used as a diagnostic aid in neuralgic amyotrophy, which was hitherto a clinical and electrophysiological diagnosis, and may also help in identifying potential surgical candidates. Muscle Nerve 56: 1054-1062, 2017. © 2017 Wiley Periodicals, Inc.

  14. Value of imaging studies after a first febrile urinary tract infection in young children: data from Italian renal infection study 1.

    PubMed

    Montini, Giovanni; Zucchetta, Pietro; Tomasi, Lisanna; Talenti, Enrico; Rigamonti, Waifro; Picco, Giorgio; Ballan, Alberto; Zucchini, Andrea; Serra, Laura; Canella, Vanna; Gheno, Marta; Venturoli, Andrea; Ranieri, Marco; Caddia, Valeria; Carasi, Carla; Dall'amico, Roberto; Hewitt, Ian

    2009-02-01

    We examined the diagnostic accuracy of routine imaging studies (ultrasonography and micturating cystography) for predicting long-term parenchymal renal damage after a first febrile urinary tract infection. This study addressed the secondary objective of a prospective trial evaluating different antibiotic regimens for the treatment of acute pyelonephritis. Data for 300 children < or =2 years of age, with normal prenatal ultrasound results, who completed the diagnostic follow-up evaluation (ultrasonography and technetium-99m-dimercaptosuccinic acid scanning within 10 days, cystography within 2 months, and repeat technetium-99m-dimercaptosuccinic acid scanning at 12 months to detect scarring) were analyzed. Outcome measures were sensitivity, specificity, and negative and positive predictive values for ultrasonography and cystography in predicting parenchymal renal damage on the 12-month technetium-99m-dimercaptosuccinic acid scans. The kidneys and urinary tracts were mostly normal. The acute technetium-99m-dimercaptosuccinic acid scans showed pyelonephritis in 54% of cases. Renal scarring developed in 15% of cases. The ultrasonographic and cystographic findings were poor predictors of long-term damage, showing minor sonographic abnormalities for 12 and reflux for 23 of the 45 children who subsequently developed scarring. The benefit of performing ultrasonography and scintigraphy in the acute phase or cystourethrography is minimal. Our findings support (1) technetium-99m-dimercaptosuccinic acid scintigraphy 6 months after infection to detect scarring that may be related to long-term hypertension, proteinuria, and renal function impairment (although the degree of scarring was generally minor and did not impair renal function) and (2) continued surveillance to identify recurrent urinary tract infections that may warrant further investigation.

  15. [Technique of abdominal ultrasonography in newborn foals and normal findings].

    PubMed

    Behn, C; Bostedt, H

    2000-09-01

    Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.

  16. The complexity of fetal imaging: reconciling clinical care with patient entertainment.

    PubMed

    Simonsen, Sara Ellis; Branch, D Ware; Rose, Nancy C

    2008-12-01

    Currently in the United States, pregnant women may obtain both medical fetal ultrasonography for screening and commercial fetal ultrasonography for entertainment purposes. The proliferation of commercial fetal ultrasonography suggests that medical screening alone does not satisfy patient expectations regarding fetal imaging. We investigated the prevalence of nonmedical fetal imaging and patient experiences and perceptions with both medical and nonmedical ultrasonography in our metropolitan area. We initiate a dialogue to explore the distinctions between medical and nonmedical fetal ultrasound imaging and the role of entertainment imaging in the medical setting. Concerns about safety, false reassurance, and unnecessary anxiety that might be generated by nonmedical ultrasonography should prompt us to examine the expectations of women regarding entertainment imaging, current clinical practice, and the potential for regulation of this commercial industry.

  17. The role of modern diagnostic imaging in diagnosing and differentiating kidney diseases in children.

    PubMed

    Maliborski, Artur; Zegadło, Arkadiusz; Placzyńska, Małgorzata; Sopińska, Małgorzata; Lichosik, Marianna; Jobs, Katarzyna

    2018-01-01

    Urinary tract diseases are in the group of the most commonly diagnosed medical conditions in pediatric patients. Many diseases with different etiologies are accompanied by pain, fever, hematuria, or urinary tract dysfunction. Those most common ones in children are urinary tract infections and congenital malformation. They can also represent tumors or changes caused by systemic diseases. Clinical tests and even more often additional imaging studies are required to make a proper diagnosis of urinary tract diseases. Just a few decades ago urography, cystography or voiding cystourethrography were the main methods in diagnostic imaging of the urinary tract. Today's imaging methods supported by digital radiographic and fluoroscopy systems, high sensitivity detectors with quantum detection, advanced algorithms eliminating motion artifacts, modern medical imaging monitors with a resolution of three or even eight megapixels significantly differ from conventional radiographic methods. The methods that are currently usually performed are: computed tomography, magnetic resonance imaging, isotopic methods and ultrasonography using elastography and new solutions in Doppler imaging. Modern techniques are currently focused on reducing radiation exposure with better imaging capabilities. The development of these techniques became an essential diagnostic aid in nephrological and urological practice. The aim of this paper is to present the latest solutions that are currently used in the diagnostic imaging of urinary tract diseases.

  18. Carpal tunnel syndrome assessment with ultrasonography: value of inlet-to-outlet median nerve area ratio in patients versus healthy volunteers.

    PubMed

    Fu, Tengfei; Cao, Manlin; Liu, Fang; Zhu, Jiaan; Ye, Dongmei; Feng, Xianxuan; Xu, Yiming; Wang, Gang; Bai, Yuehong

    2015-01-01

    To evaluate the diagnostic value of the Inlet-to-outlet median nerve area ratio (IOR) in patients with clinically and electrophysiologically confirmed carpal tunnel syndrome (CTS). Forty-six wrists in 46 consecutive patients with clinical and electrodiagnostic evidence of CTS and forty-four wrists in 44 healthy volunteers were examined with ultrasonography. The cross-sectional area (CSA) of the median nerve was measured at the carpal tunnel inlet (the level of scaphoid-pisiform) and outlet (the level of the hook of the hamate), and the IOR was calculated for each wrist. Ultrasonography and electrodiagnostic tests were performed under blinded conditions. Electrodiagnostic testing combined with clinical symptoms were considered to be the gold standard test. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic value between the inlet CSA and IOR. The study population included 16 men and 30 women (mean age, 45.3 years; range, 18-83 years). The control population included 18 men and 26 women (mean age, 50.4 years; range, 18-79 years). The mean inlet CSA was 8.7 mm2 in healthy controls and 14.6mm2 in CTS group (P<0.001). The mean IOR in healthy volunteers (1.0) was smaller than that in patients (1.6, P<0.001). Receiver operating characteristic analysis revealed a diagnostic advantage to using the IOR rather than the inlet CSA (P<0.01). An IOR cutoff value of ≥ 1.3 would yield 93% specificity and 91% sensitivity in the diagnosis of CTS. The IOR of median nerve area promises to be an effective means in the diagnosis of CTS. A large-scale, randomized controlled trial is required to determine how and when this parameter will be used.

  19. A COMPARATIVE STUDY OF REAL-TIME AND STATIC ULTRASONOGRAPHY DIAGNOSES FOR THE INCIDENTAL DETECTION OF DIFFUSE THYROID DISEASE.

    PubMed

    Kim, Dong Wook

    2015-08-01

    The aim of this study was to compare the diagnostic accuracy of real-time and static ultrasonography (US) for the incidental detection of diffuse thyroid disease (DTD). In 118 consecutive patients, a single radiologist performed real-time US before thyroidectomy. For static US, the same radiologist retrospectively investigated the sonographic findings on a picture-archiving and communication system after 3 months. The diagnostic categories of both real-time and static US diagnoses were determined based on the number of abnormal findings, and the diagnostic indices were calculated by a receiver operating characteristic (ROC) curve analysis using the histopathologic results as the reference standard. Histopathologic results included normal thyroid (n = 77), Hashimoto thyroiditis (n = 11), non-Hashimoto lymphocytic thyroiditis (n = 29), and diffuse hyperplasia (n = 1). Normal thyroid and DTD showed significant differences in echogenicity, echotexture, glandular margin, and vascularity on both real-time and static US. There was a positive correlation between US categories and histopathologic results in both real-time and static US. The highest diagnostic indices were obtained when the cutoff criteria of real-time and static US diagnoses were chosen as indeterminate and suspicious for DTD, respectively. The ROC curve analysis showed that real-time US was superior to static US in diagnostic accuracy. Both real-time and static US may be helpful for the detection of incidental DTD, but real-time US is superior to static US for detecting incidental DTD.

  20. Sensitivity and specificity of ultrasonography and low-field magnetic resonance imaging for diagnosing arthritis.

    PubMed

    Broll, Matthias; Albrecht, Katinka; Tarner, Ingo; Müller-Ladner, Ulf; Strunk, Johannes

    2012-01-01

    To evaluate the value of grey-scale ultrasonography (US) including power Doppler ultrasonography (PDUS) and low-field magnetic resonance imaging (MRI) for the diagnosis of arthritis in a diagnostic phase III study. Fifty consecutive patients with suspected arthritis were included in the study. Following a standardised protocol, US of the carpus and the metacarpophalangeal (MCP) joints of the dominant hand was performed. Subsequently, low-field MRI was done using standard sequences, with contrast agent (Gadolinium DTPA) administered to 29 patients. In 32 out of 50 patients a clinical diagnosis of arthritis was established. In grey-scale ultrasonography including PDUS, sensitivity and specificity were determined as 0.94 and 0.5, respectively, for synovitis (effusion and hypertrophy), 0.72 and 0.94, respectively, for Doppler signals, and 0.38 and 1.0, respectively, for bone erosions. In low-field MRI, sensitivity and specificity values were 0.77 and 0.75, respectively, for synovitis (when using contrast agent), 0.48 and 0.78, respectively, for bone marrow oedema, and 0.58 and 0.83, respectively, for bone erosion. Both grey-scale ultrasonography including PDUS and low-field MRI are suitable imaging methods for diagnosing arthritis at an early stage. However, PDUS displays a higher specificity and almost the same sensitivity as compared to contrast-enhanced MRI, while being a much simpler and less costly procedure.

  1. The role of orbital ultrasonography in distinguishing papilledema from pseudopapilledema

    PubMed Central

    Carter, S B; Pistilli, M; Livingston, K G; Gold, D R; Volpe, N J; Shindler, K S; Liu, G T; Tamhankar, M A

    2014-01-01

    Purpose To determine the sensitivity and specificity of orbital ultrasonography in distinguishing papilledema from pseudopapilledema in adult patients. Methods The records of all adult patients referred to the neuro-ophthalmology service who underwent orbital ultrasonography for the evaluation of suspected papilledema were reviewed. The details of history, ophthalmologic examination, and results of ancillary testing including orbital ultrasonography, MRI, and lumbar puncture were recorded. Results of orbital ultrasonography were correlated with the final diagnosis of papilledema or pseudopapilledema on the basis of the clinical impression of the neuro-ophthalmologist. Ultrasound was considered positive when the optic nerve sheath diameter was ≥3.3 mm along with a positive 30° test. Results The sensitivity of orbital ultrasonography for detection of papilledema was 90% (CI: 80.2–99.3%) and the specificity in detecting pseudopapilledema was 79% (CI: 67.7–90.7%). Conclusions Orbital ultrasonography is a rapid and noninvasive test that is highly sensitive, but less specific in differentiating papilledema from pseudopapilledema in adult patients, and can be useful in guiding further management of patients in whom the diagnosis is initially uncertain. PMID:25190532

  2. Mechanisms influencing establishment of the ovarian reserve in heifers

    USDA-ARS?s Scientific Manuscript database

    Ultrasonography serves as a diagnostic tool for understanding what is occurring at the microscopic level in the bovine ovary. Situations exist, however, in which genetic or nutritional influences can alter the population of microscopic follicles without altering the number of antral follicles obser...

  3. [Endocrine orbitopathy - the topic still alive].

    PubMed

    Fryšák, Zdeněk; Karásek, David; Halenka, Milan

    Endocrine orbitopathy (EO) must be understood mainly as a result of oxidative stress. The pathological process finally affects both the appearance and vision of the patient. In the case of inappropriate or late treatment or lack of patient cooperation, it significantly influences the quality of life of those affected. In spite of the sophisticated dia-gnostic algorithms, in some cases it is difficult to confirm the diagnosis of EO. The range of laboratory methods, the essential part of the diagnostic process, has only recently been extended by the possibility of quantification of specific, stimulating immunoglobulins (TSI). A major shortcoming may be seen in an undervalued importance of orbital ultrasonography, in particular of the eye muscles (US).Key words: biological treatment - endocrine orbitopathy (EO) - Graves-Basedow disease (GB) - "hashitoxicosis" (HTX) - hyaluronan synthase 2 (HAS2) - thyroid-blocking immunoglobulins (TBI) - thyroid-stimulating immunoglobulins (TSI) - hyaluronic acid (HA) - lymphocytary, Hashimotos thyroiditis (HT) - pulse therapy - TSH-receptor - transcription factors FOXOs - orbital ultrasonography, mainly of the eye muscles (US).

  4. Ultrasonography for the diagnosis of tendinitis and electromyography for the diagnosis of peripheral neuropathy and upper limb radiculopathy: rheumatologists' perspectives.

    PubMed

    Helfenstein, Milton; Ferreira, Mario Soares; Maia, Anna Beatriz Assad; Siena, César Augusto Fávaro; Techy, Antonio

    2013-01-01

    To ascertain the value ascribed by Brazilian rheumatologists to ultrasonography (US) for diagnosing tendinitis and to electromyography (EMG) for diagnosing peripheral neuropathy and upper limb radiculopathy. In total, 165 rheumatologists answered an anonymous survey (sent via the internet) concerning the two exams, with respect to the following characteristics: reliability, diagnostic accuracy, the importance and necessity of these tests for diagnostic The study revealed that most of the rheumatologists recognised that these exams are operator-dependent, that clinicians do not rely entirely on the results, that these exams are not mandatory for the diagnoses listed, and that professionals who perform these exams should be better trained to provide reliable results. The Brazilian rheumatologists believe the following: the results of these exams should be interpreted with caution and are not definitive for diagnosis; musculoskeletal US and EMG should be performed by trained professionals; and there must be better preparation of the professionals who perform these exams.

  5. Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography.

    PubMed

    Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide

    2016-01-01

    An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the usefulness of OXR in the diagnosis of the occult pneumothorax and to compare OXR with ultrasonography. All consecutive blunt chest trauma patients with clinically suspected pneumothorax on arrival at the emergency department were prospectively included at our tertiary-care center. The patients underwent OXR and ultrasonography, and underwent computed tomography scans as the gold standard. Occult pneumothorax size on computed tomography was classified as minuscule, anterior, or anterolateral. One hundred and fifty-nine patients were enrolled. Of the 70 occult pneumothoraces found in the 318 thoraces, 19 were minuscule, 32 were anterior, and 19 were anterolateral. The sensitivity and specificity of OXR for detecting occult pneumothorax was 61.4 % and 99.2 %, respectively. The sensitivity and specificity of lung ultrasonography was 62.9 % and 98.8 %, respectively. Among 27 occult pneumothoraces that could not be detected by OXR, 16 were minuscule and 21 could be conservatively managed without thoracostomy. OXR appears to be as good method as lung ultrasonography in the detection of large occult pneumothorax. In trauma patients who are difficult to transfer to computed tomography scan, OXR may be effective at detecting occult pneumothorax with a risk of progression.

  6. Teaching of clinical ultrasonography to undergraduates: students as mentors.

    PubMed

    García de Casasola Sánchez, G; González Peinado, D; Sánchez Gollarte, A; Muñoz Aceituno, E; Peña Vázquez, I; Torres Macho, J

    2015-05-01

    Ultrasonography is a highly useful diagnostic technique that supplements traditional physical examinations. To demonstrate that students previously trained in clinical ultrasonography are capable of instructing other students in a similar manner in a short period of time ("peer mentoring"). Five medical students in their 5th year, trained in abdominal and cardiac ultrasonography by physicians with experience, instructed 24 other students in the same procedure. The training consisted of an online theoretical course and practical training lasting about 12hours, in which each student had to perform 6 basic abdominal planes and 4 basic cardiac planes on 20 healthy volunteers. Subsequently, the students underwent an objective assessment test on healthy models performed by expert physicians in clinical ultrasonography. The students managed to correctly identify 90.2% of the basic abdominal planes, except for the left coronal (spleen and left kidney) and subcostal (gallbladder) planes, with slightly lower success rates of 82.5% and 80%, respectively. Due to the greater difficulty of obtaining cardiac planes, the success rate was lower: 70.3%, in the subxiphoid, short parasternal and four chamber planes. The cardiac plane with the fewest errors in identification was the parasternal long plane (90% success). We observed no statistically significant differences between the results (teaching capacity) of the various mentors. Medical students are capable of instructing other colleagues (peer mentoring) on the basic aspects of abdominal and cardiac ultrasonography after a relatively short training period. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  7. Prenatal Imaging: Ultrasonography and Magnetic Resonance Imaging

    PubMed Central

    Reddy, Uma M.; Filly, Roy A.; Copel, Joshua A.

    2009-01-01

    The Eunice Kennedy Shriver National Institute of Child Health and Human Development held a workshop on September 18–19, 2006, to summarize the available evidence on the role and performance of current fetal imaging technology and to establish a research agenda. Ultrasonography is the imaging modality of choice for pregnancy evaluation due to its relatively low cost, real-time capability, safety, and operator comfort and experience. First-trimester ultrasonography extends the available window for fetal observation and raises the possibility of performing an early anatomic survey. Three-dimensional ultrasonography has the potential to expand the clinical application of ultrasonography by permitting local acquisition of volumes and remote review and interpretation at specialized centers. New advances allow performance of fetal magnetic resonance imaging (MRI) without maternal or fetal sedation, with improved characterization and prediction of prognosis of certain fetal central nervous system anomalies such as ventriculomegaly when compared with ultrasonography. Fewer data exist on the usefulness of fetal MRI for non–central nervous system anomalies. PMID:18591320

  8. Role of endoscopic ultrasonography in the diagnosis of acute and chronic pancreatitis.

    PubMed

    Stevens, Tyler

    2013-10-01

    Endoscopic ultrasonography (EUS) can be a useful tool for detecting underlying causes of acute pancreatitis and establishing the severity of fibrosis in chronic pancreatitis. Ancillary techniques include fine needle aspiration and core biopsy, bile collection for crystal analysis, pancreatic function testing, and celiac plexus block. This review focuses on the role of EUS in the diagnosis of acute and chronic pancreatitis. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. A specific role of endoscopic ultrasonography for therapeutic decision-making in patients with gastric cardia cancer.

    PubMed

    Park, Chan Hyuk; Park, Jun Chul; Chung, Hyunsoo; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2016-10-01

    The role of endoscopic ultrasonography (EUS) in gastric cardia cancer should be further evaluated because the accuracy of EUS depends on tumor location. We aimed to identify a specific role of EUS for therapeutic decision-making in patients with gastric cardia cancer. Initial EUS examinations for treatment-naïve gastric cancer that were followed by endoscopic resection or surgery were included in the study. Lesions were classified as cardiac and non-cardiac cancer according to tumor location. The diagnostic performance of EUS in predicting invasion depth was compared between the two groups. The overall accuracy of EUS in predicting invasion depth did not differ between the cardiac and non-cardiac cancer groups (44.4 vs. 52.3 %, P = 0.259). The underestimation rate was higher in the cardiac cancer group than in the non-cardiac cancer group (37.0 vs. 18.5 %, P = 0.001). When the depth of invasion was predicted to be deeper than the mucosa (submucosal or deeper) by EUS, the positive predictive value was 82.1 [95 % confidence interval (CI), 66.5-92.5 %] and 62.9 % (95 % CI, 60.5-66.9 %) in the cardiac and non-cardiac cancer groups, respectively (P = 0.015). In multivariable analysis, tumor location in the cardia was found to be an independent factor for the underestimation of invasion depth [odds ratio (95 % CI) = 2.242 (1.156-4.349)]. The underestimation rate in predicting invasion depth was significantly higher for cardiac cancers than for non-cardiac cancers. Therefore, selection of the treatment method for gastric cardia cancer via EUS should be done carefully.

  10. ULTRASONOGRAPHY, AN EFFECTIVE TOOL IN DIAGNOSING PLANTAR FASCIITIS: A SYSTEMATIC REVIEW OF DIAGNOSTIC TRIALS

    PubMed Central

    Wyland, Matthew; Applequist, Lee; Bolowsky, Erin; Klingensmith, Heather; Virag, Isaac

    2016-01-01

    Background Plantar fasciitis (PF) is the most common cause of heel pain that affects 10% of the general population, whether living an athletic or sedentary lifestyle. The most frequent mechanism of injury is an inflammatory response that is caused by repetitive micro trauma. Many techniques are available to diagnose PF, including the use of ultrasonography (US). Purpose The purpose of this study is to systematically review and appraise previously published articles published between the years 2000 and 2015 that evaluated the effectiveness of using US in the process of diagnosing PF, as compared to alternative diagnostic methods. Methods A total of eight databases were searched to systematically review scholarly (peer reviewed) diagnostic and intervention articles pertaining to the ability of US to diagnose PF. Results Using specific key words the preliminary search yielded 264 articles, 10 of which were deemed relevant for inclusion in the study. Two raters independently scored each article using the 15 point modified QUADAS scale. Discussion Six studies compared the diagnostic efficacy of US to another diagnostic technique to diagnose PF, and four studies focused on comparing baseline assessment of plantar fascia before subsequent intervention. The most notable US outcomes measured were plantar fascia thickness, enthesopathy, and hypoechogenicity. Conclusion US was found to be accurate and reliable compared to alternative reference standards like MRI in the diagnosis of PF. The general advantages of US (e.g. cost efficient, ease of administration, non-invasive, limited contraindications) make it a superior diagnostic modality in the diagnosis of PF. US should be considered in rehabilitation clinics to effectively diagnose PF and to accurately monitor improvement in the disease process following rehabilitation interventions. Level of Evidence 1A PMID:27757279

  11. Sonographic diagnosis of juvenile polyps in children.

    PubMed

    Zhang, Yao; Li, Shi-Xing; Xie, Li-Mei; Shi, Bo; Ju, Hao; Bai, Yu-Zuo; Zhang, Shu-Cheng

    2012-09-01

    The aim of this study was to assess the diagnostic value of ultrasonography for juvenile polyps in children and their sonographic characteristics. A retrospective analysis was performed of the ultrasound findings in 27 children who were diagnosed preoperatively with juvenile polyp within the intestinal tract by ultrasonography and then confirmed by colonoscopy, laparotomy and histopathology. The ultrasonic finding common to all polyps was an isolated intraluminal nodular or massive protrusion, associated with multiple mesh-like fluid areas of different sizes. In 25 children, surrounding pedicle-like low echoes of varying lengths were seen connecting with the polyps to form "mushroom" sign. The color Doppler showed abundant blood flow signals within all polyps and pedicles in a shape of a branch or an umbrella. For seven children with an intussusception, the polyp shadow was detected in the cervical part or interior of the intussusception. Ultrasonography is, thus, considered to be a feasible method for diagnosing intestinal juvenile polyp. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Diagnosis of post-partum ovarian vein thrombophlebitis by color Doppler ultrasonography: about 10 cases.

    PubMed

    Giraud, J R; Poulain, P; Renaud-Giono, A; Darnault, J P; Proudhon, J F; Grall, J Y; Mocquet, P Y

    1997-09-01

    Post-partum ovarian vein thrombosis is often overlooked or mistaken for other complications such as endometritis. Color Doppler ultrasonography is a very good diagnostic method when properly indicated and correctly interpreted according to clinical data. This study reports ten cases that were retrospectively studied, during which color Doppler ultrasonography was used. The clinical signs and the results are reviewed. The lesions were clearly visualized in eight of the ten cases; one of the two failures resulted from a methodological fault (uninterpretable result); the other one was due to the lack of experience of the operator and nonrecognition of the clinical signs. Thrombosis appears as a hypoechogenic and tubular image. This type of examination is particularly indicated in the presence of certain clinical signs that were observed in our cases: fever and iliac pain are the main precursor signs, often associated with abdominal meteorism and slow digestive transit; provoked cul-de-sac pain during vaginal probing was the only constant sign, sometimes associated with painful swelling.

  13. Saline infusion sonohysterography.

    PubMed

    2004-01-01

    Saline infusion sonohysterography consists of ultrasonographic imaging of the uterus and uterocervical cavity, using real-time ultrasonography during injection of sterile saline into the uterus. When properly performed, saline infusion sonohysterography can provide information about the uterus and endometrium. The most common indication for sonohysterography is abnormal uterine bleeding. sonohysterography should not be performed in a woman who is pregnant or could be pregnant or in a woman with a pelvic infection or unexplained pelvic tenderness. Physicians who perform or supervise diagnostic saline infusion sonohysterograpy should have training, experience, and demonstrated competence in gynecologic ultrasonography and saline infusion sonohysterography. Portions of this document were developed jointly with the American College of Radiology and the American Institute of Ultrasound in Medicine.

  14. Removal of a retropharyngeal foreign body in a horse, with the aid of ultrasonography during surgery.

    PubMed

    French, D A; Pharr, J W; Fretz, P B

    1989-05-01

    Diagnostic ultrasonography was used during surgery to assist in the removal of a piece of wire from the retropharyngeal region. A 3-year-old Quarter Horse mare was referred with dysphagia of 2 days' duration. Radiography revealed a 9-cm piece of wire located caudodorsal to the larynx. A ventral surgical approach was performed, dissecting along the right side of the larynx and trachea. The surgical field was filled with 0.85% sterile physiologic saline solution. A 5 MHz-mm sector scanner probe immersed in the fluid was able to locate the wire and facilitate the direction and depth of dissection to where the wire was identified and removed.

  15. The value of ultrasonography alone in screening surveys of cystic echinococcosis in children in Turkey.

    PubMed

    Kilimcioğlu, Ali A; Ozkol, Mine; Bayindir, Petek; Girginkardeşler, Nogay; Ostan, Ipek; Ok, Ulgen Z

    2006-12-01

    A total of 1,205 primary school children were examined for cystic echinococcosis in five villages of Manisa, Turkey, to evaluate the efficacy of diagnostic methods of this infection in community-based screening surveys. Six hundred and thirty children from three villages, examined by a portable ultrasound scanner, chest microfilm and serological methods (ELISA, indirect hemagglutination) in our previous study, were designated as Study Group 1; and 575 children, from two adjacent villages, examined by ultrasonography alone in the present study, were designated as Study Group 2. In Study Group 1, hepatic cystic echinococcosis was detected in two cases (0.3%) by ultrasonography, while 43 (8.9%) and 49 (10.1%) cases were found to be positive for cystic echinococcosis by ELISA and indirect hemagglutination, respectively. Three of 575 children (0.5%) were diagnosed with cystic echinococcosis (two hepatic and one renal involvement) by ultrasonography alone in Study Group 2; and lung lesions were later detected in both cases with liver involvement by chest radiography. Our results suggested that serological tests may be beneficial in suspected cases for confirmation and differential diagnosis, but have some drawbacks, such as discrepancy in results and high false seropositivity rates. Chest microfilm is not easy in field studies and exposure to X-ray is undesirable. As a reliable, simple, inexpensive and rapid technique, ultrasonography alone is recommended to be used in community-based screening surveys for cystic echinococcosis with confirmatory tests for suspected cases found during the screening program.

  16. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study

    PubMed Central

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Introduction: Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. Methods: This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. Results: 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. Conclusion The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures. PMID:28286822

  17. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study.

    PubMed

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures.

  18. Diagnostic imaging in bovine orthopedics.

    PubMed

    Kofler, Johann; Geissbühler, Urs; Steiner, Adrian

    2014-03-01

    Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Laparoscopic-assisted extirpation of falciform ligament hemangiosarcoma in a dog.

    PubMed

    Hoddinott, Katie; Singh, Ameet; Crawford, Evan C; Guieu, Elizabeth V; Richardson, Danielle

    2015-04-01

    An 8-year-old, spayed female, bichon frisé dog had incidental nodules within its falciform ligament identified on routine abdominal ultrasonography. A laparoscopic-assisted technique provided both a diagnostic and a therapeutic treatment option. A histopathological diagnosis of hemangiosarcoma was made. This is the second case reporting hemangiosarcoma of the falciform fat.

  20. Clinics in diagnostic imaging (133). Retained placenta from an intra-abdominal pregnancy.

    PubMed

    Win, T; Tang, P H; Lim, T Y

    2011-01-01

    A 29-year-old Indonesian woman presented with abdominal pain seven months after an intra-abdominal pregnancy. Ultrasonography revealed a cystic mass in the pelvis and magnetic resonance imaging showed an umbilical stump within it, indicating a retained placenta. This was removed surgically, and on histology, an infarcted placenta was confirmed.

  1. Intermittent pancreatitis in a 2-year-old Chihuahua mixed breed dog

    PubMed Central

    2006-01-01

    Abstract A 2-year-old, female, Chihuahua mixed breed was presented on multiple occasions with vomiting and diarrhea. Diagnostic tests, including blood analyses and ultrasonography, established pancreatitis as the cause of gastrointestinal irritation. Hospitalization and supportive care, followed by maintenance of a prescription gastrointestinal diet, allowed management of the disease. PMID:16734375

  2. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    PubMed

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial neoplasia or atypical small acinar proliferation. • No significant differences were found among the three groups for cancer detection rate (P= 0.329). • Additionally, low sensitivity, specificity and accuracy of colour Doppler with or without SonoVue™ contrast agent were found. • Prostate cancer detection rate does not significantly improve with the use of colour Doppler ultrasonography with or without SonoVue™. • Although no collateral effects have been highlighted, the combined use of colour Doppler ultrasonography and SonoVue™ determines adjunctive costs and increases the mean time for taking a single prostate biopsy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  3. Optimal Combination of Non-Invasive Tools for the Early Detection of Potentially Life-Threatening Emergencies in Gynecology

    PubMed Central

    Varas, Catalina; Ravit, Marion; Mimoun, Camille; Panel, Pierre; Huchon, Cyrille; Fauconnier, Arnaud

    2016-01-01

    Objectives Potentially life-threatening gynecological emergencies (G-PLEs) are acute pelvic conditions that may spontaneously evolve into a life-threatening situation, or those for which there is a risk of sequelae or death in the absence of prompt diagnosis and treatment. The objective of this study was to identify the best combination of non-invasive diagnostic tools to ensure an accurate diagnosis and timely response when faced with G-PLEs for patients arriving with acute pelvic pain at the Gynecological Emergency Department (ED). Methods The data on non-invasive diagnostic tools were sourced from the records of patients presenting at the ED of two hospitals in the Parisian suburbs (France) with acute pelvic pain between September 2006 and April 2008. The medical history of the patients was obtained through a standardized questionnaire completed for a prospective observational study, and missing information was completed with data sourced from the medical forms. Diagnostic tool categories were predefined as a collection of signs or symptoms. We analyzed the association of each sign/symptom with G-PLEs using Pearson’s Chi-Square or Fischer’s exact tests. Symptoms and signs associated with G-PLEs (p-value < 0.20) were subjected to logistic regression to evaluate the diagnostic value of each of the predefined diagnostic tools and in various combinations. Results The data of 365 patients with acute pelvic pain were analyzed, of whom 103 were confirmed to have a PLE. We analyzed five diagnostic tools by logistic regression: Triage Process, History-Taking, Physical Examination, Ultrasonography, and Biological Exams. The combination of History-Taking and Ultrasonography had a C-index of 0.83, the highest for a model combining two tools. Conclusions The use of a standardized self-assessment questionnaire for history-taking and focal ultrasound examination were found to be the most successful tool combination for the diagnosis of gynecological emergencies in a Gynecological ED. Additional tools, such as physical examination, do not add substantial diagnostic value. PMID:27583697

  4. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    PubMed

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups <40, 40-49, 50-59 and >59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  5. Imaging of thoracic tuberculosis in children: current and future directions.

    PubMed

    Sodhi, Kushaljit Singh; Bhalla, Ashu S; Mahomed, Nasreen; Laya, Bernard F

    2017-09-01

    Tuberculosis continues to be an important cause of morbidity and mortality worldwide. It is the leading cause of infection-related deaths worldwide. Children are amongst the high-risk groups for developing tuberculosis and often pose a challenge to the clinicians in making a definitive diagnosis. The newly released global tuberculosis report from World Health Organization reveals a 50% increase in fatality from tuberculosis in children. Significantly, diagnostic and treatment algorithms of tuberculosis for children differ from those of adults. Bacteriologic confirmation of the disease is often difficult in children; hence radiologists have an important role to play in early diagnosis of this disease. Despite advancing technology, the key diagnostic imaging modalities for primary care and emergency services, especially in rural and low-resource areas, are chest radiography and ultrasonography. In this article, we discuss various diagnostic imaging modalities used in diagnosis and treatment of tuberculosis and their indications. We highlight the use of US as point-of-care service along with mediastinal US and rapid MRI protocols, especially in mediastinal lymphadenopathy and thoracic complications. MRI is the ideal modality in high-resource areas when adequate infrastructure is available. Because the prevalence of tuberculosis is highest in lower-resource countries, we also discuss global initiatives in low-resource settings.

  6. Comparison of radiography and ultrasonography for diagnosing small-intestinal mechanical obstruction in vomiting dogs.

    PubMed

    Sharma, Ajay; Thompson, Margret S; Scrivani, Peter V; Dykes, Nathan L; Yeager, Amy E; Freer, Sean R; Erb, Hollis N

    2011-01-01

    A cross-sectional study was performed on acutely vomiting dogs to compare the accuracy of radiography and ultrasonography for the diagnosis of small-intestinal mechanical obstruction and to describe several radiographic and ultrasonographic signs to identify their contribution to the final diagnosis. The sample population consisted of 82 adult dogs and small-intestinal obstruction by foreign body was confirmed in 27/82 (33%) dogs by surgery or necropsy. Radiography produced a definitive result (obstructed or not obstructed) in 58/82 (70%) of dogs; ultrasonography produced a definitive result in 80/82 (97%) of dogs. On radiographs, a diagnosis of obstruction was based on detection of segmental small-intestinal dilatation, plication, or detection of a foreign body. Approximately 30% (8/27) of obstructed dogs did not have radiographic signs of segmental small-intestinal dilatation, of which 50% (4/8) were due to linear foreign bodies. The ultrasonographic diagnosis of small-intestinal obstruction was based on detection of an obstructive lesion, sonographic signs of plication or segmental, small-intestinal dilatation. The ultrasonographic presence or absence of moderate-to-severe intestinal diameter enlargement (due to lumen dilatation) of the jejunum (>1.5 cm) was a useful discriminatory finding and, when present, should prompt a thorough search for a cause of small-intestinal obstruction. In conclusion, both abdominal radiography and abdominal ultrasonography are accurate for diagnosing small-intestinal obstruction in vomiting dogs and either may be used depending on availability and examiner choice. Abdominal ultrasonography had greater accuracy, fewer equivocal results and provided greater diagnostic confidence compared with radiography. © 2010 Veterinary Radiology & Ultrasound.

  7. The role for peer-assisted ultrasound teaching in medical school.

    PubMed

    Dickerson, Jonathan; Paul, Katie; Vila, Pierre; Whiticar, Rebecca

    2017-06-01

    Bedside ultrasonography has an increasing role in medicine yet medical students have limited exposure. Although countless hours are devoted to plain radiograph and electrocardiogram (ECG) interpretation, ultrasound is frequently glossed over. Yet this imaging modality could enhance students' understanding of anatomy, physiology and pathology, and may increase their integration into hospital teams. We aimed to investigate whether a peer-assisted ultrasound course has a place within the undergraduate medical curriculum. We describe the implementation of a course and discuss its acceptability and utility in student education. Bedside ultrasonography has an increasing role in medicine yet medical students have limited exposure METHODS: Following consultation with the medical school, an improved ultrasonography course was developed with expert guidance from an ultrasonographer and with new equipment. Sessions involved peer-tutors teaching ultrasonography techniques to medical students during emergency medicine placements. Tutees completed questionnaires to assess the quality and perceived benefits of the course and of learning ultrasonography. Both quantitative and thematic analyses of the responses were conducted by the authors. Over a period of 8 months, 105 medical students received teaching across four sessions. A total of 103 students (98%) returned questionnaires on their evaluation of the course and tutors, and on their confidence in using ultrasound. Ninety-eight per cent felt that the teaching was well delivered, 100 per cent felt that their knowledge of ultrasound had improved and 100 per cent would recommend the course. The peer-assisted ultrasound course described here enabled the majority of students to feel confident gaining elementary ultrasound views, and performing abdominal aneurysm screening and trauma assessments: techniques that they could hopefully put to use during their placements. The peer-assisted model has an acceptable role in teaching emerging clinical skills to medical students. © 2016 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  8. Ultrasonographic variations are present in the distal sesamoidean impar ligament of clinically sound horses.

    PubMed

    MacDonald, Jessica Lauren; Richter, Ruth-Anne; Wimer, Christine L

    2018-05-11

    Ultrasonography is an established diagnostic test for evaluating horses with foot pain due to suspected podotrochlear apparatus pathology. However, variations from the previously reported normal appearance of the distal sesamoidean impar ligament have not always coincided with lameness. The objective of this prospective, cross-sectional, descriptive study was to characterize variations in the ultrasonographic appearance of the distal sesamoidean impar ligament in sound horses using the transcuneal approach. Transcuneal ultrasonography of the distal sesamoidean impar ligament was performed on sound horses, and images were evaluated for fiber pattern, echogenicity, and thickness. Varying echogenicities of the distal sesamoidean impar ligament compared to the deep digital flexor tendon were found. Hypoechogenic or hyperechogenic focal areas were noted in the mid-body of the distal sesamoidean impar ligament or at its attachment to the navicular bone or the distal phalanx. In some of the sound horses, an anechoic linear area between the deep digital flexor tendon and distal sesamoidean impar ligament was observed as well as multifocal areas of hyperechogenicity or hypoechogenicity, irregular fiber pattern, and measurable thickening of the distal sesamoidean impar ligament. Several findings were bilaterally symmetrical, and no finding was always bilaterally symmetrical each time it was noted. This study supports transcuneal ultrasonography as an ancillary diagnostic tool for evaluating the equine distal sesamoidean impar ligament, describes sonographic variations in clinically sound horses, and suggests that the clinical significance of a lesion may not be determined by comparison of the distal sesamoidean impar ligament in the contralateral limb. © 2018 American College of Veterinary Radiology.

  9. Reliable and valid assessment of point-of-care ultrasonography.

    PubMed

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt; Henriksen, Birthe Merete; Hillingsø, Jens Georg; Konge, Lars; Jensen, Morten Lind; Ringsted, Charlotte

    2015-02-01

    To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. POC US is increasingly used by clinicians and is an essential part of the management of acute surgical conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different surgical patient cases in a controlled set-up. All ultrasound examinations were video-recorded and assessed by 2 blinded radiologists using OSAUS. Reliability was examined using generalizability theory. Construct validity was examined by comparing performance scores between the groups and by correlating physicians' OSAUS scores with diagnostic accuracy. The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores between the novice group (17.0; SD 8.4) and the intermediate group (30.0; SD 10.1), P = 0.007, as well as between the intermediate group and the expert group (72.9; SD 4.4), P = 0.04, and by a high correlation between OSAUS scores and diagnostic accuracy (Spearman ρ correlation coefficient = 0.76; P < 0.001). This study demonstrates high reliability as well as evidence of construct validity of the OSAUS scale for assessment of POC US competence. Hence, the OSAUS scale may be suitable for both in-training as well as end-of-training assessment.

  10. Endoscopic ultrasonography does not differentiate neoplastic from non-neoplastic small gallbladder polyps.

    PubMed

    Cheon, Young Koog; Cho, Won Young; Lee, Tae Hee; Cho, Young Deok; Moon, Jong Ho; Lee, Joon Seong; Shim, Chan Sup

    2009-05-21

    To assess the ability of endoscopic ultrasonography (EUS) to differentiate neoplastic from non-neoplastic polypoid lesions of the gallbladder (PLGs). The uses of EUS and transabdominal ultrasonography (US) were retrospectively analyzed in 94 surgical cases of gallbladder polyps less than 20 mm in diameter. The prevalence of neoplastic lesions with a diameter of 5-10 mm was 17.2% (10/58); 11-15 mm, 15.4% (4/26), and 16-20 mm, 50% (5/10). The overall diagnostic accuracies of EUS and US for small PLGs were 80.9% and 63.9% (P < 0.05), respectively. EUS correctly distinguished 12 (63.2%) of 19 neoplastic PLGs but was less accurate for polyps less than 1.0 cm (4/10, 40%) than for polyps greater than 1.0 cm (8/9, 88.9%) (P = 0.02). Although EUS was more accurate than US, its accuracy for differentiating neoplastic from non-neoplastic PLGs less than 1.0 cm was low. Thus, EUS alone is not sufficient for determining a treatment strategy for PLGs of less than 1.0 cm.

  11. Endoscopic ultrasonography does not differentiate neoplastic from non-neoplastic small gallbladder polyps

    PubMed Central

    Cheon, Young Koog; Cho, Won Young; Lee, Tae Hee; Cho, Young Deok; Moon, Jong Ho; Lee, Joon Seong; Shim, Chan Sup

    2009-01-01

    AIM: To assess the ability of endoscopic ultrasonography (EUS) to differentiate neoplastic from non-neoplastic polypoid lesions of the gallbladder (PLGs). METHODS: The uses of EUS and transabdominal ultrasonography (US) were retrospectively analyzed in 94 surgical cases of gallbladder polyps less than 20 mm in diameter. RESULTS: The prevalence of neoplastic lesions with a diameter of 5-10 mm was 17.2% (10/58); 11-15 mm, 15.4% (4/26), and 16-20 mm, 50% (5/10). The overall diagnostic accuracies of EUS and US for small PLGs were 80.9% and 63.9% (P < 0.05), respectively. EUS correctly distinguished 12 (63.2%) of 19 neoplastic PLGs but was less accurate for polyps less than 1.0 cm (4/10, 40%) than for polyps greater than 1.0 cm (8/9, 88.9%) (P = 0.02). CONCLUSION: Although EUS was more accurate than US, its accuracy for differentiating neoplastic from non-neoplastic PLGs less than 1.0 cm was low. Thus, EUS alone is not sufficient for determining a treatment strategy for PLGs of less than 1.0 cm. PMID:19452579

  12. Nanocapsules of perfluorooctyl bromide for theranostics: from formulation to targeting

    NASA Astrophysics Data System (ADS)

    Diou, O.; Fattal, E.; Payen, T.; Bridal, S. L.; Valette, J.; Tsapis, N.

    2014-03-01

    The need to detect cancer at its early stages, as well as, to deliver chemotherapy to targeted site motivates many researchers to build theranostic platforms which combine diagnostic and therapy. Among imaging modalities, ultrasonography and Magnetic Resonance Imaging (MRI) are widely available, non invasive and complement each other. Both techniques often require the use of contrast agents. We have developed nanocapsules of perfluorooctyl bromide as dual contrast agent for both imaging modalities. The soft, amorphous polymer shell provides echogenicity, while the high-density perfluorinated liquid core allows detection by 19F MRI. We have used a shell of poly(lactide-co-glycolide) (PLGA) since this polymer is biodegradable, biocompatible and can be loaded with drugs. These capsules were shown to be efficient in vitro as contrast agents for both 19F MRI and ultrasonography. In addition, for in vivo applications a poly(ethyleneglycol) (PEG) coating promotes stability and prolonged circulation. Being stealth, nanocapsule can accumulate passively into implanted tumors by the EPR effect. We will present nanocapsule formulation and characterization, and will show promising in vivo results obtained for both ultrasonography and 19F MRI.

  13. Role of Ultrasonography of Regional Nodal Basins in Staging Triple-Negative Breast Cancer and Implications For Local-Regional Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaitelman, Simona F., E-mail: sfshaitelman@mdanderson.org; Tereffe, Welela; Dogan, Basak E.

    2015-09-01

    Purpose: We sought to determine the rate at which regional nodal ultrasonography would increase the nodal disease stage in patients with triple-negative breast cancer (TNBC) beyond the clinical stage determined by physical examination and mammography alone, and significantly affect the treatments delivered to these patients. Methods and Materials: We retrospectively reviewed the charts of women with stages I to III TNBC who underwent physical examination, mammography, breast and regional nodal ultrasonography with needle biopsy of abnormal nodes, and definitive local-regional treatment at our institution between 2004 and 2011. The stages of these patients' disease with and without ultrasonography of the regionalmore » nodal basins were compared using the Pearson χ{sup 2} test. Definitive treatments of patients whose nodal disease was upstaged on the basis of ultrasonographic findings were compared to those of patients whose disease stage remained the same. Results: A total of 572 women met the study requirements. In 111 (19.4%) of these patients, regional nodal ultrasonography with needle biopsy resulted in an increase in disease stage from the original stage by physical examination and mammography alone. Significantly higher percentages of patients whose nodal disease was upstaged by ultrasonographic findings compared to that in patients whose disease was not upstaged underwent neoadjuvant systemic therapy (91.9% and 51.2%, respectively; P<.0001), axillary lymph node dissection (99.1% and 34.5%, respectively; P<.0001), and radiation to the regional nodal basins (88.2% and 29.1%, respectively; P<.0001). Conclusions: Regional nodal ultrasonography in TNBC frequently changes the initial clinical stage and plays an important role in treatment planning.« less

  14. Structured imaging technique in the gynecologic office for the diagnosis of abnormal uterine bleeding.

    PubMed

    Dueholm, Margit; Hjorth, Ina Marie D

    2017-04-01

    The aim in the diagnosis of abnormal uterine bleeding (AUB) is to identify the bleeding cause, which can be classified by the PALM-COEIN (Polyp, Adenomyosis, Leiomyoma, Malignancy (and hyperplasia), Coagulopathy, Ovulatory disorders, Endometrial, Iatrogenic and Not otherwise classified) classification system. In a gynecologic setting, the first step is most often to identify structural abnormalities (PALM causes). Common diagnostic options for the identification of the PALM include ultrasonography, endometrial sampling, and hysteroscopy. These options alone or in combination are sufficient for the diagnosis of most women with AUB. Contrast sonography with saline or gel infusion, three-dimensional ultrasonography, and magnetic resonance imaging may be included. The aim of this article is to describe how a simple structured transvaginal ultrasound can be performed and implemented in the common gynecologic practice to simplify the diagnosis of AUB and determine when additional invasive investigations are required. Structured transvaginal ultrasound for the identification of the most common endometrial and myometrial abnormalities and the most common ultrasound features are described. Moreover, situations where magnetic resonance imaging may be included are described. This article proposes a diagnostic setup in premenopausal women for the classification of AUB according to the PALM-COEIN system. Moreover, a future diagnostic setup for fast-track identification of endometrial cancer in postmenopausal women based on a structured evaluation of the endometrium is described. Copyright © 2016. Published by Elsevier Ltd.

  15. EVALUATION OF CONTRAST-ENHANCED ULTRASONOGRAPHY AS A METHOD FOR DETECTING GALLBLADDER NECROSIS OR RUPTURE IN DOGS.

    PubMed

    Bargellini, Paolo; Orlandi, Riccardo; Paloni, Chiara; Rubini, Giuseppe; Fonti, Paolo; Peterson, Mark E; Rishniw, Mark; Boiti, Cristiano

    2016-11-01

    Gall bladder necrosis and rupture are life-threatening conditions in dogs requiring surgical intervention and early diagnosis is essential. Human patients with suspected gall bladder necrosis/rupture are commonly evaluated with contrast-enhanced ultrasonography (CEUS), however this procedure has not been described in dogs with suspected gall bladder necrosis/rupture. In a prospective diagnostic cohort study, CEUS (using SonoVue contrast medium) was performed in 93 dogs with gallbladder lesions identified by abdominal conventional ultrasonography. Necrosis/rupture was identified by CEUS as a focal lack of enhancement of the gallbladder wall. Dogs with positive CEUS finding for necrosis/rupture (complete lack of regional wall enhancement) underwent immediate surgery as did dogs with other biliary disorders requiring surgery. Dogs with negative CEUS findings or those not requiring surgery were managed medically. In cases undergoing surgery, necrosis/rupture was confirmed intraoperatively (and via histopathology). Absence of necrosis/rupture was confirmed either intraoperatively (via histopathology) or was assumed to be absent by complete recovery with medical management. Forty-nine dogs underwent surgery and cholecystectomy: 24 had necrosis/rupture. CEUS was more accurate (100% sensitive and specific) in diagnosing gallbladder wall necrosis/rupture than conventional ultrasonography (75% sensitive and 81% specific) (P < 0.03). In conclusion, CEUS provides accurate characterization of gallbladder wall integrity that can impact decisions regarding clinical management, either surgical or medical. © 2016 American College of Veterinary Radiology.

  16. Transrectal contrast-enhanced ultrasonography, transrectal ultrasonography and retrograde cystography for the detection of vesicourethral anastomosis leakage after radical retropubic prostatectomy: a prospective comparative evaluation.

    PubMed

    Cantiello, Francesco; Cicione, Antonio; Autorino, Riccardo; De Nunzio, Cosimo; Tubaro, Andrea; Damiano, Rocco

    2013-01-01

    To evaluate the diagnostic accuracy of cystography (CG), transrectal ultrasonography (TRUS) and transrectal contrast-enhanced ultrasonography (CEUS) for the detection of vesicourethral extravasation (VE) after radical retropubic prostatectomy (RRP). In 80 consecutive patients who underwent RRP, the strength of the vesicourethral anastomosis (VUA) was assessed by CG, TRUS and transrectal CEUS. The investigation started with a conventional CG evaluated by an experienced uroradiologist. Following this, patients underwent TRUS which was performed by an experienced urologist who was blinded to the CG findings. The examination started with a conventional B-scan and, subsequently, a CEUS was performed by emptying and refilling the bladder with 90 ml of NaCl 0.9% + 10 ml suspension of 1:10 SonoVue and NaCl 0.9%. 26 patients (32.5%) presented urinary VE and 54 (67.5%) a watertight VUA. In 16 patients (61%) we observed a small leakage, 9 patients (35%) presented a moderate VE, and a large VE was detected in 1 patient (4%). No statistically significant difference in detection of VE was found among the three tests (p = 0.472). TRUS and CEUS are able to provide information about the integrity of the VUA that is comparable with that of CG. Copyright © 2013 S. Karger AG, Basel.

  17. B-mode and power Doppler ultrasonography of the equine suspensory ligament branches: A descriptive study on 13 horses.

    PubMed

    Rabba, Silvia; Grulke, Sigrid; Verwilghen, Denis; Evrard, Laurence; Busoni, Valeria

    2018-03-01

    Ultrasonography is routinely used to achieve the diagnosis of equine suspensory ligament desmopathy. In human medicine, power Doppler ultrasonography has also been found to be useful for the diagnosis of tendon/ligament injuries. The aim of this prospective, pilot study was to assess the presence or absence of power Doppler signal in suspensory ligament branches and compare B-mode findings with power Doppler findings in suspensory ligament branches of lame and non-lame limbs. Thirteen horses were used (eight lame horses, with lameness related to pain in the suspensory ligament branches, and five non-lame horses). Ten lame limbs and 24 sound limbs were assessed by B-mode and power Doppler ultrasonography. The severity of power Doppler signal was scored by two independent readers. The B-mode ultrasonographic examination revealed abnormalities in branches of lame limbs and in branches of sound limbs. Suspensory ligament branches that were considered normal in B-mode showed no power Doppler signal. However, power Doppler signal was detected in suspensory ligament branches that were abnormal in B-mode, both in lame and sound limbs. Power Doppler scores were subjectively higher in suspensory ligament branches of lame limbs and in branches with more severe B-mode changes. Findings supported the use of power Doppler as an adjunctive diagnostic test for lame horses with suspected suspensory desmopathy. © 2018 American College of Veterinary Radiology.

  18. Feasibility and Diagnostic Yield of Endoscopic Ultrasonography-Guided Fine Needle Biopsy With a New Core Biopsy Needle Device in Patients With Gastric Subepithelial Tumors

    PubMed Central

    Lee, Minju; Min, Byung-Hoon; Lee, Hyuk; Ahn, Sangjeong; Lee, Jun Haeng; Rhee, Poong-Lyul; Kim, Jae J.; Sohn, Tae Sung; Kim, Sung; Kim, Kyoung-Mee

    2015-01-01

    Abstract As treatment decisions for patients with gastric subepithelial tumors (SETs) largely depend on the histopathologic diagnosis, noninvasive and effective tissue acquisition methods are definitely required for proper management of gastric SETs. Recently, a new endoscopic ultrasonography-guided fine needle biopsy (EUS-FNB) device with ProCore reverse bevel technology was developed. We aimed to elucidate the feasibility and diagnostic yield of EUS-FNB with this new core biopsy needle device in patients with gastric SETs. A prospectively maintained database was retrospectively reviewed to identify consecutive patients who underwent EUS-FNB with a 22-gauge ProCore needle for gastric SETs 2 cm or larger. The main outcome measurement was the diagnostic yield of EUS-FNB. Procedure results were categorized into diagnostic, suggestive, or nondiagnostic. Of the 43 patients, needle punctures were successful in all cases irrespective of tumor location. EUS-FNB procedure results were diagnostic in 86.0%, suggestive in 4.7%, and nondiagnostic in 9.3% of cases, respectively. The diagnostic yield was the highest in fundus (100.0%), followed by body (89.5%), cardia (83.3%), and antrum (50.0%). All 18 patients with cardiac SET were finally diagnosed to have leiomyoma, and 16 patients with diagnostic or suggestive results avoided surgery. A heterogeneous echo pattern on EUS was found in 33.3% of cases with nondiagnostic or suggestive results and in 5.4% with diagnostic results. In multivariate analysis, no independent predictor of unsuccessful EUS-FNB with nondiagnostic or suggestive results was identified. Agreement between EUS-FNB and surgical pathology was 100% with respect to the diagnosis of gastrointestinal stromal tumor. However, there was a significant discrepancy in mitotic counts observed between the EUS-FNB and surgical specimens in patients with gastrointestinal stromal tumor. There were no significant procedure-related adverse events during and after the procedures. EUS-FNB with a 22G ProCore needle is a technically feasible, safe, and effective procedure for pathologic diagnosis of gastric SETs. This procedure can help refine surgical indications and facilitate a proper treatment decisions for gastric SETs, especially in the cardia. PMID:26448008

  19. Ultrasonographic evaluation of acute pelvic pain in pregnant and postpartum period.

    PubMed

    Park, Sung Bin; Han, Byoung Hee; Lee, Young Ho

    2017-04-22

    Acute pelvic pain in pregnant and postpartum patients presents diagnostic and therapeutic challenges. The interpretation of imaging findings in these patients is influenced by the knowledge of the physiological changes that occur during the pregnant and postpartum period, as well as by the clinical history. Ultrasonography remains the primary imaging investigation of the pregnant and postpartum women. This article describes the causes and imaging features of acute pelvic pain in pregnant and postpartum period and suggests characteristics to such diseases, focusing on the ultrasonography features that allow one to arrive at the corrective diagnosis. Knowledge of the clinical settings and imaging features of acute pelvic pain in pregnant and postpartum period can lead to accurate diagnosis and appropriate management of the condition.

  20. A Review and Proposed Rationale for the use of Ultrasonography as a Diagnostic Modality in the Identification of Bone Stress Injuries.

    PubMed

    Fukushima, Yaeko; Ray, Jeremiah; Kraus, Emily; Syrop, Isaac P; Fredericson, Michael

    2018-04-14

    Bone stress injuries are common in military personnel and athletes. The delayed diagnosis of a bone stress injury can lead to a more severe injury that requires a longer period of treatment. The early detection of bone stress injuries is a central part of management. Currently, the reference standard for detecting bone stress injuries is magnetic resonance imaging. However, the expanding use of point-of-care ultrasonography (US) may enable the early detection of bone stress injuries in the clinical setting. In this article, we review the US detection of bone stress injuries, as well as discuss the rationale for the use of US in the diagnosis of these injuries. © 2018 by the American Institute of Ultrasound in Medicine.

  1. Medical auditing of whole-breast screening ultrasonography

    PubMed Central

    2017-01-01

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes. PMID:28322034

  2. Medical auditing of whole-breast screening ultrasonography.

    PubMed

    Kim, Min Jung

    2017-07-01

    Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.

  3. Assessment of the Role of Different Imaging Modalities with Emphasis on Fdg Pet/Ct in the Management of Well Differentiated Thyroid Cancer (WDTC).

    PubMed

    Kendi A, Tuba Karagulle; Mudalegundi, Shwetha; Switchenko, Jeffrey; Lee, Daniel; Halkar, Raghuveer; Chen, Amy Y

    2016-01-01

    Positron emission tomography/computed tomography is suggested to have a role in detection of iodine negative recurrence in well differentiated thyroid cancer. The aim of this study is to identify role of different imaging modalities in the management of well differentiated thyroid cancer. We reviewed 900 well differentiated thyroid cancer patients after post-thyroidectomy who underwent recombinant human thyroid stimulating hormone stimulated Sodium Iodide I 131 imaging. Out of 900 patients, 74 had positron emission tomography/computed tomography. Multivariate analysis was performed by controlling positron emission tomography/computed tomography, Sodium Iodide I 131 scan, neck ultrasonography, age, sex, primary tumor size, stage, histology, thyroglobulin. Patients were grouped according to results of Sodium Iodide I 131 scan and positron emission tomography/computed tomography. Positron emission tomography/computed tomography was positive in 23 of 74 patients. The sensitivity for positron emission tomography was 11/11(100%), the specificity was 51/63 (81.0%), the positive predictive value was 11/23 (47.8%), and the negative predictive value was 51/51 (100%). The sensitivity for the neck ultrasonography was 4/8 (50%), the specificity was 53/60 (88.3%), positive predictive value was 4/11 (36.4%), and negative predictive value was 53/57 (93.0%). 50% of patients who had Sodium Iodide I 131 negative scan and positive positron emission tomography/computed tomography had a change in management. Thirty-six percent with positive neck ultrasonography had a change in management. Out of 11 recurrences, 6 had distant metastatic disease, and 5/11 had regional nodal disease. Neck ultrasonography showed nodal metastasis in 4/5 (80%). Positron emission tomography/computed tomography altered management in the presence of a high thyroglobulin level and a negative Sodium Iodide I 131 scan. Neck ultrasonography should be the first line of imaging with rising thyroglobulin levels. Positron emission tomography/computed tomography should be considered for cases with high thyroglobulin levels and normal neck ultrasonography to look for distant metastatic disease.

  4. “Nodule in Nodule” on Thyroid Ultrasonography: Possibility of Follicular Carcinoma Transformed from Benign Thyroid Tumor

    PubMed Central

    Kobayashi, Kaoru; Ota, Hisashi; Hirokawa, Mitsuyoshi; Yabuta, Tomonori; Fukushima, Mitsuhiro; Masuoka, Hiroo; Higashiyama, Takuya; Kihara, Minoru; Ito, Yasuhiro; Miya, Akihiro; Miyauchi, Akira

    2017-01-01

    Background It is generally considered impossible to differentiate follicular carcinomas from follicular adenomas by means of ultrasonography or cytology before surgery. Therefore, follicular carcinoma is histopathologically diagnosed by verifying capsular and/or vascular invasion after surgery. However, ultrasonography may play an important role in diagnosing follicular carcinoma preoperatively in a small number of cases. Case Description Four cases of follicular carcinoma or follicular neoplasm that transformed from a benign thyroid tumor and demonstrated a “nodule in nodule” appearance on ultrasonography are presented in this report. Characteristic ultrasound features of such patients are: (1) a “nodule in nodule” appearance, (2) a well-defined boundary line between the nodules, and (3) separate distribution of blood signals within each nodule. Conclusion A small number of patients with follicular carcinomas or follicular neoplasms may present with a “nodule in nodule” appearance on ultrasonography. It was suggested a long time ago that follicular carcinomas may develop from benign thyroid tumors. The fact that follicular carcinomas appear within benign tumors may be evidence of thyroid tumorigenesis. PMID:28589092

  5. Magnetic resonance imaging, ultrasonography and histology of the suspensory ligament origin: a comparative study of normal anatomy of warmblood horses.

    PubMed

    Bischofberger, A S; Konar, M; Ohlerth, S; Geyer, H; Lang, J; Ueltschi, G; Lischer, C J

    2006-11-01

    The diagnosis of lameness caused by proximal metacarpal and metatarsal pain can be challenging. Magnetic resonance imaging (MRI) offers the possibility for further diagnosis but there have been no studies on the normal MRI appearance of the origin of the suspensory ligament (OSL) in conjunction with ultrasonography and histology. To describe the MRI appearance of the OSL in fore- and hindlimbs of sound horses and compare it to the ultrasonographic and histological appearance. The findings can be used as reference values to recognise pathology in the OSL. The OSL in the fore- and hindlimbs of 6 sound horses was examined by ultrasonography prior to death, and MRI and histology post mortem. Qualitative evaluation and morphometry of the OSL were performed and results of all modalities compared. Muscular tissue, artefacts, variable SL size and shape complicated ultrasonographic interpretation. In MRI and histology the forelimb OSL consisted of 2 portions, the lateral being significantly thicker than medial. The hindlimb SL had a single large area of origin. In fore- and hindlimbs, the amount of muscular tissue was significantly larger laterally than medially. Overall SL measurements using MRI were significantly higher than using histology and ultrasonography and histological higher than ultrasonographic measurements. Morphologically, there was a good correlation between MRI and histology. MRI provides more detailed information than ultrasonography regarding muscle fibre detection and OSL dimension and correlates morphologically well with histology. Therefore, ultrasonographic results should be regarded with caution. MRI may be a diagnostic aid when other modalities fail to identify clearly the cause of proximal metacarpal and metatarsal pain; and may improve selection of adequate therapy and prognosis for injuries in this region.

  6. A new diagnostic approach to popliteal artery entrapment syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Charles; Kennedy, Dominic; Bastian-Jordan, Matthew

    A new method of diagnosing and defining functional popliteal artery entrapment syndrome is described. By combining ultrasonography and magnetic resonance imaging techniques with dynamic plantarflexion of the ankle against resistance, functional entrapment can be demonstrated and the location of the arterial occlusion identified. This combination of imaging modalities will also define muscular anatomy for guiding intervention such as surgery or Botox injection.

  7. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    PubMed Central

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  8. Patterns of the utilization of prenatal diagnosis services among pregnant women, their satisfaction and its associated factors in Viet Nam.

    PubMed

    Doan, Duong Thi Thuy; Nguyen, Huong Thi Thu; Bui, Ha Thi Thu

    2017-02-01

    This study aimed at understanding the patterns of the utilization of prenatal diagnostic (PND) services among pregnant women, their satisfaction and its associated factors at three regional prenatal diagnostic centres in Viet Nam. A cross-sectional design was used, with a consecutive sampling method to recruit pregnant women who used PND services at the three biggest regional PND services centres in Viet Nam between January and June, 2014. A total of 298 participants, about 100 participants per centre were interviewed and included in data analysis. Descriptive analyses and logistic regression methods were applied to identify association between satisfaction of women and their socio-economic characteristics. 80% of pregnant women received counselling on PND services, whilst 90% received ultrasonography services; 65.4% were satisfied with the PND services they used. Pregnant women, who were in a lower income group and received counselling but did not receive ultrasonography, were more likely to have higher satisfaction levels of PND services. A process to ensure that every pregnant woman receives sufficient PND counselling before and after receiving PND testing must be given careful and thorough consideration.

  9. Influence of environmental tobacco smoke on morphology and functions of cardiovascular system assessed using diagnostic imaging.

    PubMed

    Gać, Paweł; Poręba, Małgorzata; Pawlas, Krystyna; Sobieszczańska, Małgorzata; Poręba, Rafał

    Exposure to tobacco smoke is a significant problem of environmental medicine. Tobacco smoke contains over one thousand identified chemicals including numerous toxicants. Cardiovascular system diseases are the major cause of general mortality. The recent development of diagnostic imaging provided methods which enable faster and more precise diagnosis of numerous diseases, also those of cardiovascular system. This paper reviews the most significant scientific research concerning relationship between environmental exposure to tobacco smoke and the morphology and function of cardiovascular system carried out using diagnostic imaging methods, i.e. ultrasonography, angiography, computed tomography and magnetic resonance imaging. In the forthcoming future, the studies using current diagnostic imaging methods should contribute to the reliable documentation, followed by the wide-spreading knowledge of the harmful impact of the environmental tobacco smoke exposure on the cardiovascular system.

  10. Echinococcus multilocularis Detection in Live Eurasian Beavers (Castor fiber) Using a Combination of Laparoscopy and Abdominal Ultrasound under Field Conditions

    PubMed Central

    Gottstein, Bruno; Cracknell, John; Schwab, Gerhard; Rosell, Frank

    2015-01-01

    Echinococcus multilocularis is an important pathogenic zoonotic parasite of health concern, though absent in the United Kingdom. Eurasian beavers (Castor fiber) may act as a rare intermediate host, and so unscreened wild caught individuals may pose a potential risk of introducing this parasite to disease-free countries through translocation programs. There is currently no single definitive ante-mortem diagnostic test in intermediate hosts. An effective non-lethal diagnostic, feasible under field condition would be helpful to minimise parasite establishment risk, where indiscriminate culling is to be avoided. This study screened live beavers (captive, n = 18 or wild-trapped in Scotland, n = 12) and beaver cadavers (wild Scotland, n = 4 or Bavaria, n = 11), for the presence of E. multilocularis. Ultrasonography in combination with minimally invasive surgical examination of the abdomen by laparoscopy was viable under field conditions for real-time evaluation in beavers. Laparoscopy alone does not allow the operator to visualize the parenchyma of organs such as the liver, or inside the lumen of the gastrointestinal tract, hence the advantage of its combination with abdominal ultrasonography. All live beavers and Scottish cadavers were largely unremarkable in their haematology and serum biochemistry with no values suspicious for liver pathology or potentially indicative of E. multilocularis infection. This correlated well with ultrasound, laparoscopy, and immunoblotting, which were unremarkable in these individuals. Two wild Bavarian individuals were suspected E. multilocularis positive at post-mortem, through the presence of hepatic cysts. Sensitivity and specificity of a combination of laparoscopy and abdominal ultrasonography in the detection of parasitic liver cyst lesions was 100% in the subset of cadavers (95%Confidence Intervals 34.24–100%, and 86.7–100% respectively). For abdominal ultrasonography alone sensitivity was only 50% (95%CI 9.5–90.6%), with specificity being 100% (95%CI 79.2–100%). For laparoscopy alone sensitivity was 100% (95% CI 34.2–100%), with specificity also being 100% (95% CI 77.2–100%). Further immunoblotting, PCR and histopathological examination revealed one individual positive for E. multilocularis, whilst the other individual was positive for Taenia martis. PMID:26167927

  11. Dutch guideline for clinical foetal-neonatal and paediatric post-mortem radiology, including a review of literature.

    PubMed

    Sonnemans, L J P; Vester, M E M; Kolsteren, E E M; Erwich, J J H M; Nikkels, P G J; Kint, P A M; van Rijn, R R; Klein, W M

    2018-06-01

    Clinical post-mortem radiology is a relatively new field of expertise and not common practice in most hospitals yet. With the declining numbers of autopsies and increasing demand for quality control of clinical care, post-mortem radiology can offer a solution, or at least be complementary. A working group consisting of radiologists, pathologists and other clinical medical specialists reviewed and evaluated the literature on the diagnostic value of post-mortem conventional radiography (CR), ultrasonography, computed tomography (PMCT), magnetic resonance imaging (PMMRI), and minimally invasive autopsy (MIA). Evidence tables were built and subsequently a Dutch national evidence-based guideline for post-mortem radiology was developed. We present this evaluation of the radiological modalities in a clinical post-mortem setting, including MIA, as well as the recently published Dutch guidelines for post-mortem radiology in foetuses, neonates, and children. In general, for post-mortem radiology modalities, PMMRI is the modality of choice in foetuses, neonates, and infants, whereas PMCT is advised in older children. There is a limited role for post-mortem CR and ultrasonography. In most cases, conventional autopsy will remain the diagnostic method of choice. Based on a literature review and clinical expertise, an evidence-based guideline was developed for post-mortem radiology of foetal, neonatal, and paediatric patients. What is Known: • Post-mortem investigations serve as a quality check for the provided health care and are important for reliable epidemiological registration. • Post-mortem radiology, sometimes combined with minimally invasive techniques, is considered as an adjunct or alternative to autopsy. What is New: • We present the Dutch guidelines for post-mortem radiology in foetuses, neonates and children. • Autopsy remains the reference standard, however minimal invasive autopsy with a skeletal survey, post-mortem computed tomography, or post-mortem magnetic resonance imaging can be complementary thereof.

  12. Near-infrared Fluorescence Optical Imaging in Early Rheumatoid Arthritis: A Comparison to Magnetic Resonance Imaging and Ultrasonography.

    PubMed

    Krohn, Michaela; Ohrndorf, Sarah; Werner, Stephanie G; Schicke, Bernd; Burmester, Gerd-Rüdiger; Hamm, Bernd; Backhaus, Marina; Hermann, Kay-Geert A

    2015-07-01

    Near-infrared fluorescence optical imaging (FOI) is a novel imaging technology in the detection and evaluation of different arthritides. FOI was validated in comparison to magnetic resonance imaging (MRI), greyscale ultrasonography (GSUS), and power Doppler ultrasonography (PDUS) in patients with early rheumatoid arthritis (RA). Hands of 31 patients with early RA were examined by FOI, MRI, and US. In each modality, synovitis of the wrist, metacarpophalangeal joints (MCP) 2-5, and proximal interphalangeal joints (PIP) 2-5 were scored on a 4-point scale (0-3). Sensitivity and specificity of FOI were analyzed in comparison to MRI and US as reference methods, differentiating between 3 phases of FOI enhancement (P1-3). Intraclass correlation coefficients (ICC) were calculated to evaluate the agreement of FOI with MRI and US. A total of 279 joints (31 wrists, 124 MCP and 124 PIP joints) were evaluated. With MRI as the reference method, overall sensitivity/specificity of FOI was 0.81/0.00, 0.49/0.84, and 0.86/0.38 for wrist, MCP, and PIP joints, respectively. Under application of PDUS as reference, sensitivity was even higher, while specificity turned out to be low, except for MCP joints (0.88/0.15, 0.81/0.76, and 1.00/0.27, respectively). P2 appears to be the most sensitive FOI phase, while P1 showed the highest specificity. The best agreement of FOI was shown for PDUS, especially with regard to MCP and PIP joints (ICC of 0.57 and 0.53, respectively), while correlation with MRI was slightly lower. FOI remains an interesting diagnostic tool for patients with early RA, although this study revealed limitations concerning the detection of synovitis. Further research is needed to evaluate its full diagnostic potential in rheumatic diseases.

  13. Ultrasonography of adnexal causes of acute pelvic pain in pre-menopausal non-pregnant women

    PubMed Central

    Dupuis, Carolyn S.; Kim, Young H.

    2015-01-01

    Acute-onset pelvic pain is an extremely common symptom in premenopausal women presenting to the emergency department. After excluding pregnancy in reproductive-age women, ultrasonography plays a major role in the prompt and accurate diagnosis of adnexal causes of acute pelvic pain, such as hemorrhagic ovarian cysts, endometriosis, ovarian torsion, and tubo-ovarian abscess. Its availability, relatively low cost, and lack of ionizing radiation make ultrasonography an ideal imaging modality in women of reproductive age. The primary goal of imaging in these patients is to distinguish between adnexal causes of acute pelvic pain that may be managed conservatively or medically, and those requiring emergency/urgent surgical or percutaneous intervention. PMID:26062637

  14. Best methods for identification and treatment of PCOS.

    PubMed

    Artini, P G; Di Berardino, O M; Simi, G; Papini, F; Ruggiero, M; Monteleone, P; Cela, V

    2010-02-01

    The polycystic ovarian syndrome (PCOS) includes a wide spectrum of clinical symptoms and signs. Three different diagnostic classifications have been proposed to define this disease. The first one, published in 1990, known as the "NIH criteria" requires the simultaneous presence of hyperandrogenism and menstrual dysfunction in order to diagnose PCOS. Later on, in 2003, an expert panel met in Rotterdam and added to the previous criteria the presence of polycystic ovarian morphology detected by transvaginal ultrasonography. The later classification broadened the spectrum of PCOS and also included women with oligomenorrhea and PCO without hyperandrogenism or hyperandrogenism and PCO without menstrual dysfunction. Finally, the Androgen Excess Society, published in 2006 new diagnostic criteria which required the presence of clinical or biochemical hyperandrogenism, with either PCO or menstrual dysfunction to diagnose PCOS. This review focuses on the diagnostic techniques and methods of treatment for PCOS patients. Special attention is given to the role of insulin resistance and the potential utility of insulin sensitizers in management of the syndrome. The benefit and utmost importance of lifestyle modification for the long-term health of these women is stressed as well. It is hoped that some clarity in this regard will allow more women to not only be diagnosed and managed properly for their presenting symptoms (hirsutism, irregular menses, etc.), but also to be educated and managed for the continuing health risk of insulin resistance throughout their lives.

  15. The challenge of rapid diagnosis in oncology: Diagnostic accuracy and cost analysis of a large-scale one-stop breast clinic.

    PubMed

    Delaloge, Suzette; Bonastre, Julia; Borget, Isabelle; Garbay, Jean-Rémi; Fontenay, Rachel; Boinon, Diane; Saghatchian, Mahasti; Mathieu, Marie-Christine; Mazouni, Chafika; Rivera, Sofia; Uzan, Catherine; André, Fabrice; Dromain, Clarisse; Boyer, Bruno; Pistilli, Barbara; Azoulay, Sandy; Rimareix, Françoise; Bayou, El-Hadi; Sarfati, Benjamin; Caron, Hélène; Ghouadni, Amal; Leymarie, Nicolas; Canale, Sandra; Mons, Muriel; Arfi-Rouche, Julia; Arnedos, Monica; Suciu, Voichita; Vielh, Philippe; Balleyguier, Corinne

    2016-10-01

    Rapid diagnosis is a key issue in modern oncology, for which one-stop breast clinics are a model. We aimed to assess the diagnosis accuracy and procedure costs of a large-scale one-stop breast clinic. A total of 10,602 individuals with suspect breast lesions attended the Gustave Roussy's regional one-stop breast clinic between 2004 and 2012. The multidisciplinary clinic uses multimodal imaging together with ultrasonography-guided fine needle aspiration for masses and ultrasonography-guided and stereotactic biopsies as needed. Diagnostic accuracy was assessed by comparing one-stop diagnosis to the consolidated diagnosis obtained after surgery or biopsy or long-term monitoring. The medical cost per patient of the care pathway was assessed from patient-level data collected prospectively. Sixty-nine percent of the patients had masses, while 31% had micro-calcifications or other non-mass lesions. In 75% of the cases (87% of masses), an exact diagnosis could be given on the same day. In the base-case analysis (i.e. considering only benign and malignant lesions at one-stop and at consolidated diagnoses), the sensitivity of the one-stop clinic was 98.4%, specificity 99.8%, positive and negative predictive values 99.7% and 99.0%. In the sensitivity analysis (reclassification of suspect, atypical and undetermined lesions), diagnostic sensitivity varied from 90.3% to 98.5% and specificity varied from 94.3% to 99.8%. The mean medical cost per patient of one-stop diagnostic procedure was €420. One-stop breast clinic can provide timely and cost-efficient delivery of highly accurate diagnoses and serve as models of care for multiple settings, including rapid screening-linked diagnosis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Diagnostic Performance of Ultrasonography for Pediatric Appendicitis: A Night and Day Difference?

    PubMed

    Mangona, Kate Louise M; Guillerman, R Paul; Mangona, Victor S; Carpenter, Jennifer; Zhang, Wei; Lopez, Monica; Orth, Robert C

    2017-12-01

    For imaging pediatric appendicitis, ultrasonography (US) is preferred because of its lack of ionizing radiation, but is limited by operator dependence. This study investigates the US diagnostic performance during night shifts covered by radiology trainees compared to day shifts covered by attending radiologists. Appy-Scores (1 = completely visualized normal appendix; 2 = partially visualized normal appendix; 3 = nonvisualized appendix with no inflammatory changes in the expected region of the appendix; 4 = equivocal; 5a = nonperforated appendicitis; 5b = perforated appendicitis) from 2935 US examinations (2161:774, day-to-night) from July 2013 to 2014 were correlated with the intraoperative diagnoses and the clinical follow-up. The diagnostic performance of trainees and attendings was compared with Fisher exact test. Interobserver agreement was measured by Cohen kappa coefficient. Appendicitis prevalence was 25.3% (day) and 22.5% (night). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive vale were 94.0%, 93.7%, 93.8%, 97.9%, and 83.4% during the day and 92.0%, 91.2%, 91.3%, 97.5%, and 75.2% at night. Specificity (P = .048) and positive predictive value (P = .011) differed, with more false positives at night (7%) than during the day (4.7%). Trainee and attending agreement was high (k = 0.995), with Appy-Scores of 1, 4, and 5a most frequently discordant. US has a high diagnostic performance and interobserver agreement for pediatric appendicitis when interpreted by radiology trainees during night shifts or attending radiologists during day shifts. However, lower specificity and positive predictive value at night warrants a thorough trainee education to avoid false-positive examinations. Published by Elsevier Inc.

  17. Use of transfer learning to detect diffuse degenerative hepatic diseases from ultrasound images in dogs: A methodological study.

    PubMed

    Banzato, T; Bonsembiante, F; Aresu, L; Gelain, M E; Burti, S; Zotti, A

    2018-03-01

    The aim of this methodological study was to develop a deep convolutional neural network (DNN) to detect degenerative hepatic disease from ultrasound images of the liver in dogs and to compare the diagnostic accuracy of the newly developed DNN with that of serum biochemistry and cytology on the same samples, using histopathology as a standard. Dogs with suspected hepatic disease that had no prior history of neoplastic disease, no hepatic nodular pathology, no ascites and ultrasonography performed 24h prior to death were included in the study (n=52). Ultrasonography and serum biochemistry were performed as part of the routine clinical evaluation. On the basis of histopathology, dogs were categorised as 'normal' (n=8), or having 'vascular abnormalities'(n=8), or 'inflammatory'(n=0), 'neoplastic' (n=4) or 'degenerative'(n=32) disease; dogs with 'neoplastic' disease were excluded from further analysis. On cytological evaluation, dogs were categorised as 'normal' (n=11), or having 'inflammatory' (n=0), 'neoplastic' (n=4) or 'degenerative' (n=37) disease. Dogs were categorised as having 'degenerative' (n=32) or 'non-degenerative' (n=16) liver disease for analysis due to the limited sample size. The DNN was developed using a transfer learning methodology on a pre-trained neural network that was retrained and fine-tuned to our data set. The resultant DNN had a high diagnostic accuracy for degenerative liver disease (area under the curve 0.91; sensitivity 100%; specificity 82.8%). Cytology and serum biochemical markers (alanine transaminase and aspartate transaminase) had poor diagnostic accuracy in the detection of degenerative liver disease. The DNN outperformed all the other non-invasive diagnostic tests in the detection of degenerative liver disease. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Periportal fibrosis and other liver ultrasonography findings in vinyl chloride workers

    PubMed Central

    Maroni, M; Mocci, F; Visentin, S; Preti, G; Fanetti, A

    2003-01-01

    Aims: To investigate the presence of liver lesions and their relation with vinyl chloride monomer (VCM) exposure or other personal risk factors, in workers involved in the production of VCM and polyvinyl chloride (PVC). Methods: A liver ultrasonography examination was conducted in 757 workers, some of whom had long standing service in the production of VCM and PVC. The study involved: assessment of individual past and present VCM exposure of each worker; collection of past personal health history, lifestyle and personal data; routine liver function tests; and liver ultrasonography. Results: No cases of liver malignancies were detected. Angiomas and liver cysts were found with a frequency of occurrence within the expected range of the general population. The main findings consisted of hepatomegaly (34.7%), steatosis (31.8%), and periportal fibrosis (16.0%). A logistic regression analysis indicated that hepatomegaly and steatosis were associated with obesity and lipid metabolism disturbances and not with VCM exposure. Periportal fibrosis, in addition to constitutional or dietary factors, was shown to be associated with VCM exposure, but only when maximum exposure in the subject's history had been at least 200 ppm as a yearly average; no effects were observed at 50 ppm or below. Conclusions: Workers exposed to 200 ppm VCM for at least one year have a fourfold increased risk of developing periportal liver fibrosis. Liver ultrasonography is a suitable and important diagnostic test for the medical surveillance of vinyl chloride workers. PMID:12499459

  19. Endoanal ultrasonography in fecal incontinence: Current and future perspectives.

    PubMed

    Albuquerque, Andreia

    2015-06-10

    Fecal incontinence has a profound impact in a patient's life, impairing quality of life and carrying a substantial economic burden due to health costs. It is an underdiagnosed condition because many affected patients are reluctant to report it and also clinicians are usually not alert to it. Patient evaluation with a detailed clinical history and examination is very important to indicate the type of injury that is present. Endoanal ultrasonography is currently the gold standard for sphincter evaluation in fecal incontinence and is a simple, well-tolerated and non-expensive technique. Most studies revealed 100% sensitivity in identifying sphincter defect. It is better than endoanal magnetic resonance imaging for internal anal sphincter defects, equivalent for the diagnosis of external anal sphincter defects, but with a lower capacity for assessment of atrophy of this sphincter. The most common cause of fecal incontinence is anal sphincter injury related to obstetric trauma. Only a small percentage of women are diagnosed with sphincter tears immediately after vaginal delivery, but endoanal ultrasonography shows that one third of these women have occult sphincter defects. Furthermore, in patients submitted to primary repair of these tears, ultrasound revealed a high frequency of persistent sphincter defects after surgery. Three-dimensional endoanal ultrasonography is currently largely used and accepted for sphincter evaluation in fecal incontinence, improving diagnostic accuracy and our knowledge of physiologic and pathological sphincters alterations. Conversely, there is currently no evidence to support the use of elastography in fecal incontinence evaluation.

  20. Ultrasonographic findings in hereditary neuropathy with liability to pressure palsies.

    PubMed

    Bayrak, Ayse O; Bayrak, Ilkay Koray; Battaloglu, Esra; Ozes, Burcak; Yildiz, Onur; Onar, Musa Kazim

    2015-02-01

    The aims of this study were to evaluate the sonographic findings of patients with hereditary neuropathy with liability to pressure palsies (HNPP) and to examine the correlation between sonographic and electrophysiological findings. Nine patients whose electrophysiological findings indicated HNPP and whose diagnosis was confirmed by genetic analysis were enrolled in the study. The median, ulnar, peroneal, and tibial nerves were evaluated by ultrasonography. We ultrasonographically evaluated 18 median, ulnar, peroneal, and tibial nerves. Nerve enlargement was identified in the median, ulnar, and peroneal nerves at the typical sites of compression. None of the patients had nerve enlargement at a site of noncompression. None of the tibial nerves had increased cross-sectional area (CSA) values. There were no significant differences in median, ulnar, and peroneal nerve distal motor latencies (DMLs) between the patients with an increased CSA and those with a normal CSA. In most cases, there was no correlation between electrophysiological abnormalities and clinical or sonographic findings. Although multiple nerve enlargements at typical entrapment sites on sonographic evaluation can suggest HNPP, ultrasonography cannot be used as a diagnostic tool for HNPP. Ultrasonography may contribute to the differential diagnosis of HNPP and other demyelinating polyneuropathies or compression neuropathies; however, further studies are required.

  1. The role of CEUS in characterization of superficial lymph nodes: a single center prospective study

    PubMed Central

    de Stefano, Giorgio; Scognamiglio, Umberto; Di Martino, Filomena; Parrella, Roberto; Scarano, Francesco; Signoriello, Giuseppe; Farella, Nunzia

    2016-01-01

    Accurate lymph node characterization is important in a large number of clinical settings. We evaluated the usefulness of Contrast Enhanced Ultrasound (CEUS) in distinguishing between benign and malignant lymph nodes compared with conventional ultrasonography in the differential diagnosis of superficial lymphadenopathy. We present our experience for 111 patients enrolled in a single center. 111 superficial lymph nodes were selected and only 1 lymph node per patient underwent CEUS. A definitive diagnosis for all lymph nodes was obtained by ultrasonographically guided biopsy and/or excision biopsy. The size of the lymph nodes, the site (neck, axilla, inguinal region) being easily accessible for biopsy, and the US and color Doppler US characteristics guided us in selecting the nodes to be evaluated by CEUS. In our study we identified different enhancement patterns in benign and malignant lymph nodes, with a high degree of diagnostic accuracy for superficial lymphadenopathy in comparison with conventional US. PMID:27191746

  2. Contrast-enhanced endoscopic ultrasonography: advance and current status

    PubMed Central

    2014-01-01

    Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review. PMID:25038805

  3. The role of routine preoperative EUS when performed after contrast enhanced CT in the diagnostic work-up in patients suspected of pancreatic or periampullary cancer.

    PubMed

    Cieslak, Kasia P; van Santvoort, Hjalmar C; Vleggaar, Frank P; van Leeuwen, Maarten S; ten Kate, Fibo J; Besselink, Marc G; Molenaar, I Quintus

    2014-01-01

    In patients suspected of pancreatic or periampullary cancer, abdominal contrast-enhanced computed tomography (CT) is the standard diagnostic modality. A supplementary endoscopic ultrasonography (EUS) is often performed, although there is only limited evidence of its additional diagnostic value. The aim of the study is to evaluate the additional diagnostic value of EUS over CT in deciding on exploratory laparotomy in patients suspected of pancreatic or periampullary cancer. We retrospectively analyzed 86 consecutive patients who routinely underwent CT and EUS before exploratory laparotomy with or without pancreatoduodenectomy for suspected pancreatic or periampullary carcinoma between 2007 and 2010. Primary outcomes were visibility of a mass, resectability on CT/EUS and resection with curative intent. A mass was visible on CT in 72/86 (84%) patients. In these 72 patients, EUS demonstrated a mass in 64/72 (89%) patients. Resectability was accurately predicted by CT in 65/72 (90%) and by EUS in 58/72 (81%) patients. In 14/86 (16%) patients no mass was seen on CT. EUS showed a mass in 12/14 (86%) of these patients. A malignant lesion was histological proven in 11/12 (92%) of these patients. Overall, resectability was accurately predicted by CT and EUS in 90% (77/86) and 84% (72/86), respectively. In patients with a visible mass on CT, suspected for pancreatic or periampullary cancer, EUS has no additional diagnostic value, does not influence the decision to perform laparotomy and should therefore not be performed routinely. In patients without a visible mass on CT, EUS is useful to confirm the presence of a tumor. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  4. Radiologic evaluation of nonalcoholic fatty liver disease

    PubMed Central

    Lee, Seung Soo; Park, Seong Ho

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a frequent cause of chronic liver diseases, ranging from simple steatosis to nonalcoholic steatohepatitis (NASH)-related liver cirrhosis. Although liver biopsy is still the gold standard for the diagnosis of NAFLD, especially for the diagnosis of NASH, imaging methods have been increasingly accepted as noninvasive alternatives to liver biopsy. Ultrasonography is a well-established and cost-effective imaging technique for the diagnosis of hepatic steatosis, especially for screening a large population at risk of NAFLD. Ultrasonography has a reasonable accuracy in detecting moderate-to-severe hepatic steatosis although it is less accurate for detecting mild hepatic steatosis, operator-dependent, and rather qualitative. Computed tomography is not appropriate for general population assessment of hepatic steatosis given its inaccuracy in detecting mild hepatic steatosis and potential radiation hazard. However, computed tomography may be effective in specific clinical situations, such as evaluation of donor candidates for hepatic transplantation. Magnetic resonance spectroscopy and magnetic resonance imaging are now regarded as the most accurate practical methods of measuring liver fat in clinical practice, especially for longitudinal follow-up of patients with NAFLD. Ultrasound elastography and magnetic resonance elastography are increasingly used to evaluate the degree of liver fibrosis in patients with NAFLD and to differentiate NASH from simple steatosis. This article will review current imaging methods used to evaluate hepatic steatosis, including the diagnostic accuracy, limitations, and practical applicability of each method. It will also briefly describe the potential role of elastography techniques in the evaluation of patients with NAFLD. PMID:24966609

  5. A comparative study of endoscopic ultrasonography versus endoscopic retrograde cholangiopancreatography in children with chronic liver disease.

    PubMed

    El-Karaksy, Hanaa M; El-Koofy, Nehal M; Okasha, Hussein; Kamal, Naglaa M; Naga, Mazen

    2008-09-01

    Endoscopic ultrasonography (EUS) is a less invasive modality and may be equal or superior to endoscopic retrograde cholangiopancreatography (ERCP) in visualizing the biliary tree. Its role and feasibility in children need to be accurately defined. This study aimed at evaluation of EUS in assessment of children with chronic liver disease (CLD) in comparison with ERCP. The present study was carried out between September 2004 and February 2006 on 40 children suffering from CLD. Patients were selected from the Pediatric Hepatology Unit, Cairo University Children's Hospital, Egypt. They were included if they had: sonographic (n = 8) or histopathological evidence of biliary pathology (n = 2); autoimmune hepatitis with high gamma glutammyl transpeptidase (GGT) levels and/or not responding to immunosuppressive therapy (n = 15); cryptogenic CLD (n = 13); neonatal cholestasis with relapsing or persistent course (n = 2). They all underwent EUS and ERCP. Three of six cases with intrahepatic biliary radicle dilatation had Caroli's disease by EUS and ERCP; and the other 3 had sclerosing cholangitis. EUS was equal to ERCP in diagnosis of biliary pathology. However, one false positive case was described to have dilatation and tortuosity of the pancreatic duct by EUS as compared to ERCP. EUS could detect early pancreatitis in 5 cases. One case with cryptogenic liver disease proved to have sclerosing cholangitis by both EUS and ERCP. EUS is an important diagnostic tool for biliary pathology and pancreatitis in children with pancreatico-biliary pathology. ERCP should be reserved for therapeutic purposes.

  6. [Accuracy of placenta accreta prenatal diagnosis by ultrasound and MRI in a high-risk population].

    PubMed

    Daney de Marcillac, F; Molière, S; Pinton, A; Weingertner, A-S; Fritz, G; Viville, B; Roedlich, M-N; Gaudineau, A; Sananes, N; Favre, R; Nisand, I; Langer, B

    2016-02-01

    Main objective was to compare accuracy of ultrasonography and MRI for antenatal diagnosis of placenta accreta. Secondary objectives were to specify the most common sonographic and RMI signs associated with diagnosis of placenta accreta. This retrospective study used data collected from all potential cases of placenta accreta (patients with an anterior placenta praevia with history of scarred uterus) admitted from 01/2010 to 12/2014 in a level III maternity unit in Strasbourg, France. High-risk patients beneficiated antenatally from ultrasonography and MRI. Sonographic signs registered were: abnormal placental lacunae, increased vascularity on color Doppler, absence of the retroplacental clear space, interrupted bladder line. MRI signs registered were: abnormal uterine bulging, intraplacental bands of low signal intensity on T2-weighted images, increased vascularity, heterogeneous signal of the placenta on T2-weighed, interrupted bladder line, protrusion of the placenta into the cervix. Diagnosis of placenta accreta was confirmed histologically after hysterectomy or clinically in case of successful conservative treatment. Twenty-two potential cases of placenta accreta were referred to our center and underwent both ultrasonography and MRI. All cases of placenta accreta had a placenta praevia associated with history of scarred uterus. Sensibility and specificity for ultrasonography were, respectively, 0.92 and 0.67, for MRI 0.84 and 0.78 without significant difference (p>0.05). The most relevant signs associated with diagnosis of placenta accreta in ultrasonography were increased vascularity on color Doppler (sensibility 0.85/specificity 0.78), abnormal placental lacunae (sensibility 0.92/specificity 0.55) and loss of retroplacental clear space (sensibility 0.76/specificity 1.0). The most relevant signs in MRI were: abnormal uterine bulging (sensitivity 0.92/specificity 0.89), dark intraplacental bands on T2-weighted images (sensitivity 0.83/specificity 0.80) or placental heterogeneity (sensitivity 0.92/specificity 0.89). Association of two sonographic or MRI signs had the best sensitivity/specificity ratio. Ultrasonography and RMI represent two interesting and complementary diagnostic tools for antenatal diagnosis of placenta accreta. Because of its cost and accessibility, ultrasonography remains the first in line to be used for diagnosis. Use of an analytical grid for diagnosis of placenta accreta could be helpful. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. International guidelines for contrast-enhanced ultrasonography: ultrasound imaging in the new millennium

    PubMed Central

    Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramatically extended, and now includes functional imaging and tissue characterization, which in many cases enable tumor diagnosis without a biopsy. It is virtually impossible to imagine the practice of modern medicine as we know it in high-income countries without the use of imaging, and yet, an estimated two thirds of the global population may receive no such care. Ultrasound imaging with CEUS has the potential to correct this inequity. PMID:26867761

  8. Detection of residual disease after neoadjuvant chemoradiotherapy for oesophageal cancer (preSANO): a prospective multicentre, diagnostic cohort study.

    PubMed

    Noordman, Bo Jan; Spaander, Manon C W; Valkema, Roelf; Wijnhoven, Bas P L; van Berge Henegouwen, Mark I; Shapiro, Joël; Biermann, Katharina; van der Gaast, Ate; van Hillegersberg, Richard; Hulshof, Maarten C C M; Krishnadath, Kausilia K; Lagarde, Sjoerd M; Nieuwenhuijzen, Grard A P; Oostenbrug, Liekele E; Siersema, Peter D; Schoon, Erik J; Sosef, Meindert N; Steyerberg, Ewout W; van Lanschot, J Jan B

    2018-05-31

    After neoadjuvant chemoradiotherapy for oesophageal cancer, roughly half of the patients with squamous cell carcinoma and a quarter of those with adenocarcinoma have a pathological complete response of the primary tumour before surgery. Thus, the necessity of standard oesophagectomy after neoadjuvant chemoradiotherapy should be reconsidered for patients who respond sufficiently to neoadjuvant treatment. In this study, we aimed to establish the accuracy of detection of residual disease after neoadjuvant chemoradiotherapy with different diagnostic approaches, and the optimal combination of diagnostic techniques for clinical response evaluations. The preSANO trial was a prospective, multicentre, diagnostic cohort study at six centres in the Netherlands. Eligible patients were aged 18 years or older, had histologically proven, resectable, squamous cell carcinoma or adenocarcinoma of the oesophagus or oesophagogastric junction, and were eligible for potential curative therapy with neoadjuvant chemoradiotherapy (five weekly cycles of carboplatin [area under the curve 2 mg/mL per min] plus paclitaxel [50 mg/m 2 of body-surface area] combined with 41·4 Gy radiotherapy in 23 fractions) followed by oesophagectomy. 4-6 weeks after completion of neoadjuvant chemoradiotherapy, patients had oesophagogastroduodenoscopy with biopsies and endoscopic ultrasonography with measurement of maximum tumour thickness. Patients with histologically proven locoregional residual disease or no-pass during endoscopy and without distant metastases underwent immediate surgical resection. In the remaining patients a second clinical response evaluation was done (PET-CT, oesophagogastroduodenoscopy with biopsies, endoscopic ultrasonography with measurement of maximum tumour thickness, and fine-needle aspiration of suspicious lymph nodes), followed by surgery 12-14 weeks after completion of neoadjuvant chemoradiotherapy. The primary endpoint was the correlation between clinical response during clinical response evaluations and the final pathological response in resection specimens, as shown by the proportion of tumour regression grade (TRG) 3 or 4 (>10% residual carcinoma in the resection specimen) residual tumours that was missed during clinical response evaluations. This study was registered with the Netherlands Trial Register (NTR4834), and has been completed. Between July 22, 2013, and Dec 28, 2016, 219 patients were included, 207 of whom were included in the analyses. Eight of 26 TRG3 or TRG4 tumours (31% [95% CI 17-50]) were missed by endoscopy with regular biopsies and fine-needle aspiration. Four of 41 TRG3 or TRG4 tumours (10% [95% CI 4-23]) were missed with bite-on-bite biopsies and fine-needle aspiration. Endoscopic ultrasonography with maximum tumour thickness measurement missed TRG3 or TRG4 residual tumours in 11 of 39 patients (28% [95% CI 17-44]). PET-CT missed six of 41 TRG3 or TRG4 tumours (15% [95% CI 7-28]). PET-CT detected interval distant histologically proven metastases in 18 (9%) of 190 patients (one squamous cell carcinoma, 17 adenocarcinomas). After neoadjuvant chemoradiotherapy for oesophageal cancer, clinical response evaluation with endoscopic ultrasonography, bite-on-bite biopsies, and fine-needle aspiration of suspicious lymph nodes was adequate for detection of locoregional residual disease, with PET-CT for detection of interval metastases. Active surveillance with this combination of diagnostic modalities is now being assessed in a phase 3 randomised controlled trial (SANO trial; Netherlands Trial Register NTR6803). Dutch Cancer Society. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. The role of ultrasonography in examination of the stability of Tile-B2 pelvic fractures: 7 case reports and a literature review.

    PubMed

    Zhang, Bin-Fei; Zhang, Hong; Wang, Peng-Fei; Wang, Hu; Lei, Jin-Lai; Fu, Ya-Hui; Cong, Yu-Xuan; Huang, Hai; Huo, Xiao-Ming; Zhuang, Yan; Zhang, Kun

    2017-09-01

    Determining whether a Tile-B2 pelvic fracture is stable is very challenging. We sought to identify the role of ultrasonography in determining the stability of Tile-B2 pelvic fractures. We collected the clinical data of patients with Tile-B2 pelvic fractures who presented at Xi'an Hong-Hui Hospital between June 1, 2016, and August 5, 2016. The treatment strategy of each patient was determined by a team of senior surgeons in the department. A single sinologist observed the movement of the fracture sites in patients during rest, under compression, and during separation to determine fracture stability. According to the pelvic fracture stability assessment, an appropriate treatment strategy was redetermined. Overall, 7 patients, including 5 women and 2 men, with Tile-B2 pelvic fractures were included in this case series. During the initial examination, senior surgeons recommended that 2 patients should undergo internal fixation and 4 patients, conservative treatment; treatment was undecided for 1 patient. After ultrasonography examination, 4 patients underwent surgery via the Stoppa (n = 2) or ilioinguinal approach (n = 1) or cannulated screw fixation (n = 1). The rest of the patients (n = 3) received conventional treatment. Follow-up ranged from 6 to 10 months. Most of the patients showed excellent functions based on their last Majeed grading scores. There were no complications during the follow-up. Using ultrasonography examination, the preoperative treatment plan in 1 patient was changed, and the uncertain preoperative plan in 1 patient was identified. Preoperative assessment of stability using ultrasonography may assist surgeons in making appropriate treatment choices for patients with Tile-B2 pelvic fractures.

  10. Thyroid sonography as an effective tool to discriminate between euthyroid sick and hypothyroid dogs.

    PubMed

    Reese, Sven; Breyer, Ulrike; Deeg, Cornelia; Kraft, Wilfried; Kaspers, Bernd

    2005-01-01

    The diagnosis of canine hypothyroidism and its differentiation from euthyroid sick syndrome still is a major diagnostic challenge. In this study, ultrasonography was shown to be an effective tool for the investigation of thyroid gland diseases. Healthy control dogs (n = 87), dogs with euthyroid sick syndrome (n = 26), thyroglobulin autoantibody-positive (TgAA-positive, n = 30) hypothyroid dogs, and TgAA-negative (n = 23) hypothyroid dogs were examined by thyroid ultrasonography. Maximal cross sectional area (MCSA), thyroid volume, and echogenicity were measured. Statistical analysis identified highly significant (P < .001) differences between euthyroid and hypothyroid dogs both in thyroid volume and in MCSA, whereas no significant differences in thyroid size were detected between healthy euthyroid dogs and dogs with euthyroid sick syndrome. In euthyroid and euthyroid sick dogs, parenchymal echotexture was homogeneous and hyperechoic, whereas relative thyroid echogenicity of both TgAA-positive and TgAA-negative hypothyroid dogs was significantly lower (P < .001). When using arbitrarily chosen cutoff values for relative thyroid volume, MCSA, and echogenicity, thyroid volume especially was found to have highly specific predictive value for canine hypothyroidism. In summary, the data reveal that thyroid sonography is an effective ancillary diagnostic tool to differentiate between canine hypothyroidism and euthyroid sick syndrome.

  11. Diagnostic accuracy of ultrasonography in detection of blunt abdominal trauma and comparison of early and late ultrasonography 24 hours after trauma.

    PubMed

    Feyzi, Ali; Rad, Masoud Pezeshki; Ahanchi, Navid; Firoozabadi, Jalil

    2015-01-01

    Despite the advantages of ultrasound scan, its use as a screening tool in blunt abdominal trauma is controversial. The aim of this study was to evaluate the diagnostic value of early and late ultrasound in patients with blunt abdominal trauma (BAT). In this study which was performed in a level I trauma center, firstly, 2418 patients with BAT had ultrasound (US) examination by two trauma expert radiologists. Results were compared with the best available gold standards such as laparotomy, CT, repeated ultrasound or clinical course follow-up. Then, 400 patients with BAT were examined by a trained residency student. In the first phase, sensitivity, specificity, negative predictive value, positive predictive value and accuracy of ultrasound were 97%, 98.1%, 99.7%, 83% and 98% respectively. In the second phase, they were 97.3%, 97.2%, 97.7%, 96.8% and 97.3% for the early and 98.5%, 97.6%, 98.5%, 97.5% and 98% for the late ultrasound respectively. Results obtained from this study indicate that negative ultrasound findings associated with negative clinical observation virtually exclude abdominal injury, and confirmation by performing other tests is unnecessary. High sensitivity and negative predictive value is achieved if ultrasound is performed by expert trauma radiologist.

  12. Bedside ultrasonography for diagnosis of pneumothorax

    PubMed Central

    Chen, Lin

    2015-01-01

    Ultrasonography (US) has found its way into the critical care and emergency settings for the evaluation of acute respiratory failure conditions in recent years. It is useful for the diagnosis of varieties of abnormalities involving pleura and lung such as pleural effusion, alveolar interstitial syndrome, and pneumothorax (PTX). In addition to its reproducibility and timeliness, US has high sensitivity and specificity for the diagnosis of these conditions. The most widely used method for bedside evaluation of PTX is chest X-ray (CXR). However, the diagnostic sensitivity of CXR in detecting PTX is limited especially in occult PTX and when the patient is assumed supine position. Computed tomography (CT) is the gold standard in the evaluation of PTX, but is limited by its high radiation exposure and safety concerns in transporting critically ill patients. In this paper we review current advances in PTX diagnosis using US. PMID:26435925

  13. Experimental study of microwave-induced thermoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Jacobs, Ryan T.

    Microwave-Induced Thermoacoustic Imaging (TAI) is a noninvasive hybrid modality which improves contrast by using thermoelastic wave generation induced by microwave absorption. Ultrasonography is widely used in medical practice as a low-cost alternative and supplement to magnetic resonance imaging (MRI). Although ultrasonography has relatively high image resolution (depending on the ultrasonic wavelength at diagnostic frequencies), it suffers from low image contrast of soft tissues. In this work samples are irradiated with sub-microsecond electromagnetic pulses inducing acoustic waves in the sample that are then detected with an unfocused transducer. The advantage of this hybrid modality is the ability to take advantage of the microwave absorption coefficients which provide high contrast in tissue samples. This in combination with the superior spatial resolution of ultrasound waves is important to providing a low-cost alternative to MRI and early breast cancer detection methods. This work describes the implementation of a thermoacoustic experiment using a 5 kW peak power microwave source.

  14. Evaluation of diaphragmatic motion in normal and diaphragmatic paralyzed dogs using M-mode ultrasonography.

    PubMed

    Choi, Mihyun; Lee, Namsoon; Kim, Ahyoung; Keh, Seoyeon; Lee, Jinsoo; Kim, Hyunwook; Choi, Mincheol

    2014-01-01

    Diagnosis of unilateral diaphragmatic paralysis in dogs is currently based on fluoroscopic detection of unequal movement between the crura. Bilateral paralysis may be more difficult to confirm with fluoroscopy because diaphragmatic movement is sometimes produced by compensatory abdominal muscle contractions. The purpose of this study was to develop a new method to evaluate diaphragmatic movement using M-mode ultrasonography and to describe findings for normal and diaphragmatic paralyzed dogs. Fifty-five clinically normal dogs and two dogs with diaphragmatic paralysis were recruited. Thoracic radiographs were acquired for all dogs and fluoroscopy studies were also acquired for clinically affected dogs. Two observers independently measured diaphragmatic direction of motion and amplitude of excursion using M-mode ultrasonography for dogs meeting study inclusion criteria. Eight of the clinically normal dogs were excluded due to abnormal thoracic radiographic findings. For the remaining normal dogs, the lower limit values of diaphragmatic excursion were 2.85-2.98 mm during normal breathing. One dog with bilateral diaphragmatic paralysis showed paradoxical movement of both crura at the end of inspiration. One dog with unilateral diaphragmatic paralysis had diaphragmatic excursion values of 2.00 ± 0.42 mm on the left side and 4.05 ± 1.48 mm on the right side. The difference between left and right diaphragmatic excursion values was 55%. Findings indicated that M-mode ultrasonography is a relatively simple and objective method for measuring diaphragmatic movement in dogs. Future studies are needed in a larger number of dogs with diaphragmatic paralysis to determine the diagnostic sensitivity of this promising new technique. © 2013 American College of Veterinary Radiology.

  15. Integrating trans-abdominal ultrasonography with fecal steroid metabolite monitoring to accurately diagnose pregnancy and predict the timing of parturition in the red panda (Ailurus fulgens styani).

    PubMed

    Curry, Erin; Browning, Lissa J; Reinhart, Paul; Roth, Terri L

    2017-05-01

    Red pandas (Ailurus fulgens styani) exhibit a variable gestation length and may experience a pseudopregnancy indistinguishable from true pregnancy; therefore, it is not possible to deduce an individual's true pregnancy status and parturition date based on breeding dates or fecal progesterone excretion patterns alone. The goal of this study was to evaluate the use of transabdominal ultrasonography for pregnancy diagnosis in red pandas. Two to three females were monitored over 4 consecutive years, generating a total of seven profiles (four pregnancies, two pseudopregnancies, and one lost pregnancy). Fecal samples were collected and assayed for progesterone (P4) and estrogen conjugate (EC) to characterize patterns associated with breeding activity and parturition events. Animals were trained for voluntary transabdominal ultrasound and examinations were performed weekly. Breeding behaviors and fecal EC data suggest that the estrus cycle of this species is 11-12 days in length. Fecal steroid metabolite analyses also revealed that neither P4 nor EC concentrations were suitable indicators of pregnancy in this species; however, a secondary increase in P4 occurred 69-71 days prior to parturition in all pregnant females, presumably coinciding with embryo implantation. Using ultrasonography, embryos were detected as early as 62 days post-breeding/50 days pre-partum and serial measurements of uterine lumen diameter were documented throughout four pregnancies. Advances in reproductive diagnostics, such as the implementation of ultrasonography, may facilitate improved husbandry of pregnant females and allow for the accurate prediction of parturition. © 2017 Wiley Periodicals, Inc.

  16. Clinical findings and results of diagnostic imaging in 82 dogs with gastrointestinal ulceration.

    PubMed

    Fitzgerald, E; Barfield, D; Lee, K C L; Lamb, C R

    2017-04-01

    To describe clinical and imaging findings in dogs with confirmed gastrointestinal ulceration, to compare findings in dogs with perforated and non-perforated ulcers and to estimate the sensitivities of radiography, ultrasonography and computed tomography (CT) for gastrointestinal ulceration and perforation. Retrospective review of medical records of 82 dogs that had a macroscopic ulcer in the gastric or intestinal mucosa diagnosed directly at endoscopy, surgery or necropsy and had survey radiography, ultrasonography or a CT scan of the abdomen during the same period of hospitalisation. The most frequent clinical signs were vomiting in 88% dogs, haematemesis in 32%, melaena in 31% and weight loss in 7%. The most frequent imaging findings in dogs with non-perforated ulcers were gastrointestinal mural lesion in 56%, mucosal defect compatible with an ulcer in 44% and peritoneal fluid in 21%. In dogs with perforated ulcers the most frequent imaging findings were peritoneal fluid in 83%, gastrointestinal mural lesion in 48%, peritoneal gas in 31% and mucosal defect compatible with an ulcer in 29%. Sensitivities of radiography, ultrasonography and CT were 30, 65 and 67% in dogs with non-perforated ulcers and 79, 86 and 93% in dogs with perforated ulcers, respectively. In dogs with non-perforated ulcers, survey radiography was usually negative whereas ultrasonography and CT frequently enabled detection of the site of the ulcer; in dogs with perforated ulcers, radiography was frequently positive for peritoneal gas and CT was a sensitive modality for both the ulcer and signs of perforation. © 2017 British Small Animal Veterinary Association.

  17. Impact of target organ damage assessment in the evaluation of global risk in patients with essential hypertension.

    PubMed

    Viazzi, Francesca; Leoncini, Giovanna; Parodi, Denise; Ratto, Elena; Vettoretti, Simone; Vaccaro, Valentina; Parodi, Angelica; Falqui, Valeria; Tomolillo, Cinzia; Deferrari, Giacomo; Pontremoli, Roberto

    2005-03-01

    Accurate assessment of cardiovascular risk is a key step toward optimizing the treatment of hypertensive patients. We analyzed the impact and cost-effectiveness of routine, thorough assessment of target organ damage (TOD) in evaluating risk profile in hypertension. A total of 380 never-treated patients with essential hypertension underwent routine work-up plus evaluation of albuminuria and ultrasonography of cardiac and vascular structures. The impact of these tests on risk stratification, as indicated by European Society of Hypertension-European Society of Cardiology guidelines, was assessed in light of their cost and sensitivity. The combined use of all of these tests greatly improved the detection of TOD, therefore leading to the identification of a higher percentage of patients who were at high/very high risk, as compared with those who were detected by routine clinical work-up (73% instead of 42%; P < 0.0001). Different signs of TOD only partly cluster within the same subgroup of patients; thus, all three tests should be performed to maximize the sensitivity of the evaluation process. The diagnostic algorithm yielding the lowest cost per detected case of TOD is the search for microalbuminuria, followed by echocardiography and then carotid ultrasonography. Adopting lower cut-off values to define microalbuminuria allows us to optimize further the cost-effectiveness of diagnostic algorithms. In conclusion, because of its low cost and widespread availability, measuring albuminuria is an attractive and cost-effective screening test that is especially suitable as the first step in the large-scale diagnostic work-up of hypertensive patients.

  18. [Doppler ultrasonography of the renal artery: Guidelines and predictive factors for the presence of a tight stenosis. Retrospective analysis of 450 consecutive examinations].

    PubMed

    Dejerome, C; Grange, C; De Laforcade, L; Bonin, O; Laville, M; Lermusiaux, P; Long, A

    2018-05-01

    Duplex ultrasonography screening for renal artery stenosis has been the object of guidelines published by four societies designed to optimize the cost-effectiveness of the examination. To determine how well guideline indications for ultrasonography matched with requests and results in our university hospital; to determine whether compliance with guidelines was predictive of renal artery stenosis; to identify guidelines predictive of presence of stenosis; and to determine whether other predictive factors can be recognized. Requests and results of 450 Duplex ultrasonography examinations of the renal arteries performed from January 1st 2014 to December 31st 2015 were compared with published guidelines. At least one guideline indication was identified for 212 of the 450 examinations performed (47.1%). Among these examinations, renal artery stenosis≥70% was identified in 18 patients (8.0%). No case of stenosis was identified during examinations performed outside guideline indications. Factors predictive of stenosis were: compliance with guidelines (OR=21.86 [2.88; 165.8]). Predictive guidelines were: resistant hypertension in spite of appropriate treatment (OR=3.85, [1.44; 10.33], P=0.011), accelerated hypertension (OR=7.30, [1.40; 37.99], P=0.049), sudden unexplained pulmonary edema (OR=7.30, [1.40; 37.99], P=0.049), unexplained renal insufficiency (OR=3.58, [1.37; 9.37], P=0.011), unexplained renal hypotrophy (OR=16.69, [4.38; 63.69], P<0.001), renal asymmetry (OR=4.32, [1.45; 12.85], P<0.016). No other factor was predictive of renal stenosis. These examinations had therapeutic consequences in only 50% of patients. This study confirms the relevance of published guidelines. The diagnostic-effectiveness of Duplex ultrasonography examinations to search for renal artery stenosis depends upon compliance with these guidelines. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  19. Imaging of gout: an overview.

    PubMed

    Dalbeth, Nicola; Doyle, Anthony J

    2012-12-01

    The diverse clinical states and sites of pathology in gout provide challenges when considering the features apparent on imaging. Ideally, an imaging modality should capture all aspects of disease including monosodium urate crystal deposition, acute inflammation, tophus, tissue remodelling and complications of disease. The modalities used in gout include conventional radiography, ultrasonography, magnetic resonance imaging, computed tomography and dual-energy computed tomography. This review discusses the role of each of these imaging modalities in gout, focussing on the imaging characteristics, role in gout diagnosis and role for disease monitoring. Ultrasonography and dual-energy computed tomography are particularly promising methods for both non-invasive diagnosis and monitoring of disease. The observation that ultrasonographic appearances of monosodium urate crystal deposition can be observed in patients with hyperuricaemia but no other clinical features of gout raises important questions about disease definitions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. A comparative study of two-dimensional and three-dimensional ultrasonography in evaluation of gastric affections in dogs

    PubMed Central

    Pal, Madan; Singh, Prem; Tayal, Rishi; Dehmiwal, Dinesh; Behl, S. M.; Kumar, Sarvan; Chandolia, R. K

    2015-01-01

    Aim: The objective of the study was to obtain and compare the two-dimensional (2D) and three-dimensional (3D) ultrasonographic images of pathological conditions of the stomach in dogs in clinical cases. Materials and Methods: In our study, 12 clinical conditions of the stomach were recorded using ultrasonography. The ultrasound machine used for this study was 3D ultrasound machine (Nemio-XG: Toshiba, Japan) having four-dimensional volumetric transducer. Results: Present study was done to compare 2D and 3D ultrasonographic images in different gastric affections in dogs. In case of uremic gastropathy due to inflammatory response, the wall of the stomach was 0.6 cm thick and hyperechoic and gastric folds were also hyperechoic indicative of gastritis. In second, third, and fourth case of gastritis the wall of the stomach was 0.7, 0.6, and 0.55 cm, respectively thick and hyperechoic. In fifth and sixth case of gastritis, inflammatory response due to ingestion of polythene and sand led to gastritis and ultrasonographically, the wall of the stomach was 0.6 cm and 0.7 cm thick, respectively, and hyperechoic. In case of gastric ulcer, ultrasonographically, there was a disruption of gastric mucosal layer. In cases of gastric dilatation, anechoic content indicating fluid was seen in stomach area and due to dilatation boundary of the stomach was not clear and the increase in the lumen of the stomach was observed. In case of foreign body, ultrasonographically the wall of the stomach was 0.55 cm thick and hyperechoic. In the middle of the stomach, multiple hyperechoic shadows of the foreign bodies i.e. leather and bunch of straw of grass were observed. In case of pyloric stenosis ultrasonographically, anechoic lumen of the pylorus surrounded by 0.5 cm hypoechoic thickened muscle. In some cases, 3D ultrasonography was not diagnostic i.e. gastric foreign bodies and gastric dilatation. These conditions were better visualized on the 2D sonogram. Conclusion: The appearance of clinical conditions of the stomach such as gastritis and pyloric stenosis were more distinct on 3D ultrasonogram than 2D ultrasonogram. The 3D ultrasonography was not diagnostic in cases of gastric foreign bodies and gastric dilatation. PMID:27065634

  1. Penile fracture with urethral trauma.

    PubMed

    de Carvalho, Arlindo Monteiro; de Melo, Fábio Martinez; Félix, Gabriella Alves de Lima; Sarmento, Juliana Fernandes; Capriglione, Maria Luisa Dutra

    2013-01-01

    We reported a case of a twenty-nine-year-old male who presented a penile fracture associated with urethral injury caused by a sexual intercourse. An ideal anamnesis and a special physical examination were determinant to correct diagnostics. Ultrasonography and uretrocistography must be performed for confirmation. The treatment is based on the presence of associated urethral injury. The surgical repair of cavernous body and urethra can produce good results, with a favorable prognosis and minimal rate of complications.

  2. Diagnostic Tools of Pleural Effusion

    PubMed Central

    2014-01-01

    Pleural effusion is not a rare disease in Korea. The diagnosis of pleural effusion is very difficult, even though the patients often complain of typical symptoms indicating of pleural diseases. Pleural effusion is characterized by the pleural cavity filled with transudative or exudative pleural fluids, and it is developed by various etiologies. The presence of pleural effusion can be confirmed by radiological studies including simple chest radiography, ultrasonography, or computed tomography. Identifying the causes of pleural effusions by pleural fluid analysis is essential for proper treatments. This review article provides information on the diagnostic approaches of pleural effusions and further suggested ways to confirm their various etiologies, by using the most recent journals for references. PMID:24920946

  3. B-Flow Imaging in Lower Limb Peripheral Arterial Disease and Bypass Graft Ultrasonography.

    PubMed

    D'Abate, Fabrizio; Ramachandran, Veni; Young, Mark A; Farrah, John; Ahmed, Mudasar H; Jones, Keith; Hinchliffe, Robert J

    2016-09-01

    Doppler ultrasonography plays a key role in the diagnosis of peripheral arterial disease, but is often limited by pitfalls that may be overcome by B-flow imaging. Thus far, there is little information on B-flow imaging for the assessment of peripheral arterial disease and bypass grafts in lower limbs. This article describes the authors' early experience with B-flow in the lower extremities. Sixty patients were included among a large cohort of patients routinely referred to the vascular laboratory for peripheral arterial disease and bypass graft assessments. Two experienced vascular sonographers performed all scans, comparing color Doppler ultrasonography with B-flow imaging. All scans were performed using a combination of the 9 L linear and C2-9 curvilinear transducers with the LOGIQ E9 system (GE Healthcare, Waukesha, WI, USA). Our experience indicates that this relatively unexplored technology has the potential to significantly improve peripheral blood flow evaluation. Nevertheless, B-flow imaging is not exempt from limitations and should be considered complementary to color Doppler ultrasonography. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. From a genetic innovation to mass health programmes: the diffusion of Down's Syndrome prenatal screening and diagnostic techniques in France.

    PubMed

    Vassy, Carine

    2006-10-01

    Down's Syndrome prenatal diagnostic and screening techniques have spread widely in France over the last 30 years and are now part of the routine clinical practice of prenatal care. These techniques, which originated in the field of genetics, ultrasonography and biochemistry, were the first to provide the possibility of choosing the features of the foetus, or at least to reject some of its characteristics. They lead to new norms of healthy foetuses and a progressive acceptance of medical abortions. The aim of this paper is to understand how the use of these tests has been generalised in France despite scientific controversies about their risks and ethical questioning about a potential renewal of eugenics. It analyses the representations of public needs that have been articulated by key players in the scientific and medical fields. This research explores political and administrative decision making processes to understand how progressively widening public access to prenatal testing has been organised and funded. The results highlight the scientific and political role of biomedical researchers, the forms of involvement of health authorities and politicians, and the passive participation of the vast majority of the users. The paper also examines the characteristics of the French health system that facilitated the generalised use of the technology.

  5. Power Doppler Ultrasonography and Shear Wave Elastography as Complementary Imaging Methods for Suspected Local Breast Cancer Recurrence.

    PubMed

    Jales, Rodrigo Menezes; Dória, Maira Teixeira; Serra, Kátia Piton; Miranda, Mila Meneguelli; Menossi, Carlos Alberto; Schumacher, Klaus; Sarian, Luis Otávio

    2018-06-01

    To prospectively investigate the diagnostic accuracy and clinical consequences of power Doppler morphologic criteria and shear wave elastography (SWE) as complementary imaging methods for evaluation of suspected local breast cancer recurrence in the ipsilateral breast or chest wall. Thirty-two breast masses with a suspicion of local breast cancer recurrence on B-mode ultrasonography underwent complementary power Doppler and SWE evaluations. Power Doppler morphologic criteria were classified as avascular, hypovascular, or hypervascular. Shear wave elastography was classified according to a 5-point scale (SWE score) and SWE maximum elasticity. Diagnostic accuracy was assessed by the sensitivity, specificity, and area under the curve. A decision curve analysis assessed clinical consequences of each method. The reference standard for diagnosis was defined as core needle or excisional biopsy. Histopathologic examinations revealed 9 (28.2%) benign and 23 (71.8%) malignant cases. Power Doppler ultrasonography (US) had sensitivity of 34.8% (95% confidence interval [CI], 6.6%-62.9%) and specificity of 45.4% (95% CI, 19.3%-71.5%). The SWE score (≥3) had sensitivity of 87.0% (95% CI, 66.4%-97.2%) and specificity of 44.4% (95% CI, 13.7%-78.8%). The SWE maximum elasticity (velocity > 6.5cm/s) had sensitivity of 87% (95% CI, 66.4%-97.2%) and specificity of 77.8% (95% CI, 40.0% to 97.2%). The areas under the curves for the SWE score and SWE maximum elasticity were 0.71 (95% CI, 0.53-0.87) and 0.82 (95% CI, 0.64-0.93), respectively (P = .32). Power Doppler US is unsuitable for discrimination between local breast cancer recurrence and fibrosis. Although the SWE score and SWE maximum elasticity can make this discrimination, the use of these methods to determine biopsy may lead to poorer clinical outcomes than the current practice of performing biopsies of all suspicious masses. © 2017 by the American Institute of Ultrasound in Medicine.

  6. Age, tumor size, and in-office ultrasonography are predictive parameters of malignancy in follicular neoplasms of the thyroid.

    PubMed

    Paramo, Juan C; Mesko, Thomas

    2008-01-01

    To identify clinical predictors of malignancy in patients with intraoperative frozen-section diagnosis of follicular neoplasm of the thyroid. We performed a retrospective cross-sectional study of 71 patients with intraoperative frozen-section diagnosis of follicular neoplasm who underwent thyroidectomy between January 1992 and December 2000. Age, sex, tumor size, and in-office ultrasonography characteristics of the lesions were assessed. These clinical factors were compared between cases that had benign definitive pathologic findings and those that were found to be carcinomas on permanent sections. Nine (13%) of the 71 follicular neoplasms were found to be carcinomas after definitive pathologic evaluation. The incidence of malignancy was 13% (2/16) in men and 13% (7/55) in women (P>.5). Patients younger than 45 years had a 27% (8/30) incidence of malignancy compared with 2% (1/41) in patients 45 years or older (P<.01). Of tumors smaller than 4 cm, 7% (4/55) were ultimately diagnosed as carcinomas compared with 31% (5/16) of those 4 cm or larger (P = .05). When the in-office ultrasonography findings were interpreted as benign, only 7% (3/46) of cases were malignant compared with 40% (4/10) when the ultrasonography findings were suspicious (P = .02). Age and tumor size are predictive parameters of malignancy in follicular neoplasm of the thyroid. Suspicious ultrasonography findings also have an important predictive role. Total thyroidectomy is reasonable in patients with follicular neoplasm on frozen section if they are young (<45 years old), with large (>4 cm) tumors or if there are suspicious findings on in-office ultrasonography.

  7. Alpha-fetoprotein and its value for predicting pregnancy outcomes – a re-evaluation

    PubMed Central

    Darouich, Ayham Alhaj; Liehr, Thomas; Weise, Anja; Schlembach, Dietmar; Schleußner, Ekkehart; Kiehntopf, Michael; Schreyer, Isolde

    2015-01-01

    Introduction Alpha-fetoprotein (AFP) concentrations can be determined framing others from invasively acquired amnion fluid (AF-AFP). While the biological role of AFP remains unclear it is well known that AFP-levels can be altered in connection with specific clinical and/or genetic alterations of the fetus. Materials and Method here a retrospective study based on 3,119 singleton and 56 twin pregnancies is presented. The standard levels of amnion fluid derived alpha-fetoprotein level (AF-AFP) between 12th and 36th weeks of gestation were determined. Additionally, acetylcholinesterase (AChE) test results for 63 cases, ultrasonography results for 32 cases and abnormal karyotypic findings for 100 cases were available for selected cases. Results and Discussion according to the present data the AF-AFP test is reliable and provides expected test results in terms of population studies. However, individual AF-AFP test results can be subject to high individual variations. In this study AF-AFP multiple of medians (MoM) over 1.7 were indicative for neuronal tube defects and/or omphalocele in only 6.3% of the cases, while such AF-AFP values were hints on severe sonographic signs in 62% of the cases. Also, altered AF-AFP concentrations were present in 82% of cytogenetically abnormal cases. Overall, even though predicative value of the AF-AFP-test is matter of discussion it continues to be widely applied in invasive prenatal diagnostics. This study indicates that it only can be applied reliably in combination with other tests like banding cytogenetics, ultrasonography and all embedded in well-established genetic counseling. PMID:27358693

  8. Multicentre external validation of IOTA prediction models and RMI by operators with varied training

    PubMed Central

    Sayasneh, A; Wynants, L; Preisler, J; Kaijser, J; Johnson, S; Stalder, C; Husicka, R; Abdallah, Y; Raslan, F; Drought, A; Smith, A A; Ghaem-Maghami, S; Epstein, E; Van Calster, B; Timmerman, D; Bourne, T

    2013-01-01

    Background: Correct characterisation of ovarian tumours is critical to optimise patient care. The purpose of this study is to evaluate the diagnostic performance of the International Ovarian Tumour Analysis (IOTA) logistic regression model (LR2), ultrasound Simple Rules (SR), the Risk of Malignancy Index (RMI) and subjective assessment (SA) for preoperative characterisation of adnexal masses, when ultrasonography is performed by examiners with different background training and experience. Methods: A 2-year prospective multicentre cross-sectional study. Thirty-five level II ultrasound examiners contributed in three UK hospitals. Transvaginal ultrasonography was performed using a standardised approach. The final outcome was the surgical findings and histological diagnosis. To characterise the adnexal masses, the six-variable prediction model (LR2) with a cutoff of 0.1, the RMI with cutoff of 200, ten SR (five rules for malignancy and five rules for benignity) and SA were applied. The area under the curves (AUCs) for performance of LR2 and RMI were calculated. Diagnostic performance measures for all models assessed were sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR−), and the diagnostic odds ratio (DOR). Results: Nine-hundred and sixty-two women with adnexal masses underwent transvaginal ultrasonography, whereas 255 had surgery. Prevalence of malignancy was 29% (49 primary invasive epithelial ovarian cancers, 18 borderline ovarian tumours, and 7 metastatic tumours). The AUCs for LR2 and RMI for all masses were 0.94 (95% confidence interval (CI): 0.89–0.97) and 0.90 (95% CI: 0.83–0.94), respectively. In premenopausal women, LR2−RMI difference was 0.09 (95% CI: 0.03–0.15) compared with −0.02 (95% CI: −0.08 to 0.04) in postmenopausal women. For all masses, the DORs for LR2, RMI, SR+SA (using SA when SR inapplicable), SR+MA (assuming malignancy when SR inapplicable), and SA were 62 (95% CI: 27–142), 43 (95% CI: 19–97), 109 (95% CI: 44–274), 66 (95% CI: 27–158), and 70 (95% CI: 30–163), respectively. Conclusion: Overall, the test performance of IOTA prediction models and rules as well as the RMI was maintained in examiners with varying levels of training and experience. PMID:23674083

  9. Fracture of the penis: a radiological or clinical diagnosis? A case series and literature review.

    PubMed

    Agarwal, Mayank Mohan; Singh, Shrawan K; Sharma, Darshan Kumar; Ranjan, Priyadarshi; Kumar, Santosh; Chandramohan, Vaddi; Gupta, Nitin; Acharya, Naveen C; Bhalla, Vidur; Mavuduru, Ravimohan; Mandal, Arup K

    2009-04-01

    Fracture of the penis is rare and needs a surgeon's attention for appropriate management. The exact role of diagnostic investigations has not been established. We studied the role of these investigations and the results of surgery. Seventeen patients with median age of 36 years (range, 27-72 years) presented to us between 2002 and 2007 with suspected fracture of the penis. The mode of injury was sexual intercourse (15 patients), masturbation (1 patient), and rolling over in bed (1 patient). The median time from injury to presentation was 10 hours (range, 1-144 hours). Clinical evaluation included patient history and examination for all patients, ultrasonography in 6 patients, retrograde urethrography in 6 patients, and magnetic resonance imaging in 1 patient. Fifteen patients underwent immediate surgical exploration, 1 patient was kept under observation, and 1 patient refused surgical exploration. Patient history and clinical examination were highly sensitive and accurate in predicting a cavernosal tear, and retrograde urethrography was highly sensitive and accurate in detecting urethral injury. Ultrasonography was highly specific but not sensitive for detecting a cavernosal tear. Radiological investigations did not influence patient management in any of the cases. On surgical exploration, 15 patients had cavernosal tears and 4 also had urethral injuries; all injuries were repaired successfully. One patient had a negative surgical exploration and was diagnosed as having a superficial dorsal vein rupture. One patient had a history suggestive of penile fracture but had a normal clinical examination and was kept under observation. At follow up in a mean of 7.5 months, no patient had erectile dysfunction or penile deformity. Further evaluation beyond taking a patient history and performing a clinical examination is not necessary in most cases for managing patients with suspected penile fracture. Retrograde urethrography may be omitted before surgical exploration, even in cases with suspected urethral injury. Early surgical repair is associated with a good outcome with minimal complications.

  10. [Screening of benign and malignant thyroid nodules in 5 196 physical examination population].

    PubMed

    Li, M H; Liu, J T

    2018-02-23

    Objective: To investigate the distribution characteristics of thyroid nodules and thyroid cancer in physical examination population in Tianjin, and report the outcome of ultrasonography in detection of thyroid nodules. Methods: Enrolled all of physical examination population in our hospital from Jan 1, 2014 to Dec 31, 2014 as our study subjects then the thyroid gland lesions were screened by ultrasound diagnostic technique. The risk assessment of benign and malignant thyroid nodules was assessed by ultrasonography and thyroid imaging reporting and data system (TI-RADS), and the individuals were followed up for 1 year. Results: Among the 5 196 cases, the patients with thyroid nodules was 2 068 cases (39.80%). The thyroid nodules was 35.04% in male and 44.78% in female subjects, lower in females than in male cases ( P <0.001). 18 cases of thyroid cancer patients were detected (0.35%). The thyroid cancer rate were 0.34% and 0.36% in male and female respectively ( P >0.05). Thyroid nodules increased with age, but the thyroid cancer patients were mainly concentrated in the 30 to 39 years old group and 50 to 59 years old group. All of the thyroid cancer patients underwent surgical treatment, better differentiation thyroid papillary carcinoma (17 cases) in major, most were early stage cancer and micro-cancer, possessing relatively low risk of recurrence. The sensitivity, specificity and accuracy of ultrasonography and TI-RADS diagnosis of thyroid cancer was 72.22%, 98.94% and 98.85%. Conclusions: The detection rate of thyroid nodules in our population is close to 40%, and there are differences between sexes and ages. Ultrasonography and TI-RADS association is an efficient method to detect the nodules in thyroid.

  11. Evaluation of lymph node perfusion using continuous mode harmonic ultrasonography with a second-generation contrast agent.

    PubMed

    Rubaltelli, Leopoldo; Khadivi, Yeganeh; Tregnaghi, Alberto; Stramare, Roberto; Ferro, Federica; Borsato, Simonetta; Fiocco, Ugo; Adami, Fausto; Rossi, Carlo Riccardo

    2004-06-01

    To evaluate the contribution of continuous mode contrast-enhanced harmonic ultrasonography (CE-HUS) with a second-generation contrast agent to the characterization of superficial lymphadenopathies with respect to conventional ultrasonographic techniques (B-mode and power Doppler). Fifty-six lymph nodes from 45 patients were studied both by conventional techniques and by CE-HUS. The dimensions, intranodal architecture, margins, and location of vessels were evaluated. Subsequently, all the lymph nodes were examined by CE-HUS, and enhancement of echogenicity was evaluated. The diagnoses obtained by means of fine-needle aspiration cytologic examination, surgical biopsy, or both were compared with those obtained by ultrasonography. Of the lymph nodes examined, 30 were benign and 26 were malignant (18 metastases and 8 non-Hodgkin lymphomas). The study using CE-HUS showed intense homogeneous enhancement in 28 of 30 reactive lymph nodes; perfusion defects in 17, of which 15 were neoplastic and 2 were inflammatory; intense but inhomogeneous speckled enhancement in the early arterial phase in 5 cases of lymphoma; and, last, scarce or absent intranodal enhancement in 4 metastases. The specificity, sensitivity, and accuracy of conventional techniques in differentiation between benign and malignant lymph nodes were 76%, 80%, and 78% versus 93%, 92%, and 92.8% for CE-HUS. The increase in correct diagnoses was significant (P = .05) when conventional ultrasonography was tested against CE-HUS. Superficial lymph nodes can be characterized as being neoplastic or benign with a high degree of diagnostic accuracy on the basis of the perfusion characteristics evaluated by CE-HUS. This technique has been shown to afford a higher degree of accuracy than currently obtainable by any other ultrasonographic technique.

  12. The role of transvaginal ultrasonography for detecting ovarian cancer in an asymptomatic screening population: a systematic review.

    PubMed

    Buhling, Kai J; Lezon, S; Eulenburg, C; Schmalfeldt, B

    2017-05-01

    The purpose of this study was to systematically analyze the effect of transvaginal ultrasonography in an asymptomatic female population as an annual screening procedure with regard to mortality data. Studies were evaluated descriptively on their strengths and weaknesses considering the methods and results. We evaluated 632 international studies by selecting only randomized controlled trials (RCTs). Three RCTs concerning transvaginal ultrasonography were found, performed in Japan, the USA, and Great Britain. Currently, no clear recommendation for the screening for ovarian cancer in an asymptomatic population can be given based on these three studies. The authors could not show a change in mortality using transvaginal ultrasonography for annual screening. An annual palpation does not offer a beneficial effect. The development of new ultrasound machines with higher image resolution in combination with a well-standardized algorithm for ovarian cancer in upcoming years might provide an improvement regarding mortality. The current studies do not show a benefit in screening an asymptomatic population annually with transvaginal ultrasonography, but the most recent publication showed a trend toward lower mortality in patients who underwent screening after 7-14 years of follow-up. Nevertheless, all three heterogeneous RCTs had weaknesses in their methods and therefore they neither contradict the general recommendation for screening in an asymptomatic population nor do they support it.

  13. Mandibular fracture caused by periodontal abscess: Radiological, US, CT and MRI findings.

    PubMed

    Mazza, D; Marini, M; Tesei, J; Primicerio, P

    2006-09-01

    Mandibular fracture is a rare but possible outcome of a periodontal abscess. A case of complete fracture of the mandible with abscess infiltrating the surrounding soft tissues is described. The patient reported nor trauma, nor locoregional surgery. Ultrasonography and orthopantomography revealed the fracture of the mandible and the abscess at the masseter muscle. Further preoperative diagnostic examinations included CT and MRI. CT revealed the complete fracture line more clearly; MR the extension of the abscess.

  14. [Duodenal leiomyosarcoma. Apropos of a case].

    PubMed

    Galliou, G; Nonent, M; Kergastel, I; Le Guyader, J

    1995-01-01

    The authors report a new case of leiomyosarcoma of the duodenum. The exoluminal growth and the volume of this tumor explain the difficulties of the imaging methods diagnostic. Computed tomography, magnetic resonance imaging and angiography were not sufficient to determine the origin of the tumor. Surgical exposure itself was not conclusive and only pathology provided the definitive diagnosis. We think that endoscopic ultrasonography should be indicated in these submucosal tumors of the duodenum to differentiate them from pancreatic neoplasms.

  15. Assessment of total placenta previa by magnetic resonance imaging and ultrasonography to detect placenta accreta and its variants.

    PubMed

    Peker, Nuri; Turan, Volkan; Ergenoglu, Mete; Yeniel, Ozgur; Sever, Ahmet; Kazandi, Mert; Zekioglu, Osman

    2013-03-01

    To evaluate the importance of ultrasonography (US) and magnetic resonance imaging (MRI) in detecting placental adherence defects. Patients diagnozed with total placenta previa (n = 40) in whom hysterectomy was performed due to placental adherence defects (n = 20) or in whom the placenta detached spontaneously after a Cesarean delivery (n = 20) were included into the study between June 2008 and January 2011, at the Department of Obstetrics and Gynecology Ege University (lzmir Turkey). Gray-scale US was used to check for any placental lacunae, sub-placental sonolucent spaces or a placental mass invading the vesicouterine plane and bladder Intra-placental lacunar turbulent blood flow and an increase in vascularization in the vesicouterine plane were evaluated with color Doppler mode. Subsequently all patients had MRI and the results were compared with the histopathologic examinations. The sensitivity of MRI for diagnosis of placental adherence defects before the operation was 95%, with a specificity of 95%. In the presence of at least one diagnostic criterion, the sensitivity and specificity of US were 87.5% and 100% respectively, while the sensitivity of color Doppler US was 62.5% with a specificity of 100%. Currently MRI appears to be the gold standard for the diagnosis of placenta accreta. None of the ultrasonographic criteria is solely sufficient to diagnose placental adherence defects, however they assist in the diagnostic process.

  16. Ultrasound as Diagnostic Tool for Diaphragmatic Myoclonus

    PubMed Central

    Llaneza Ramos, Vesper Fe Marie; Considine, Elaine; Karp, Barbara I.; Lungu, Codrin; Alter, Katharine; Hallett, Mark

    2015-01-01

    Background Diaphragmatic myoclonus is a rare disorder of repetitive diaphragmatic contractions, acknowledged to be a spectrum that includes psychogenic features. Electromyography has been the diagnostic tool most commonly used in the literature. Methods To test if we could perform a noninvasive technique to delineate the diaphragm as the source of abnormal movements and demonstrate distractibility and entrainability, we used B-mode ultrasound in a patient with diaphragmatic myoclonus. Results Ultrasound imaging clearly delineated the diaphragm as the source of her abdominal movements. We were able to demonstrate entrainability of the diaphragm to hand tapping to a prescribed rhythm set by examiner. Conclusion We recommend the use of ultrasound as a noninvasive, convenient diagnostic tool for further studies of diaphragmatic myoclonus. We agree with previous findings that diaphragmatic myoclonus may be a functional movement disorder, as evidenced by distractibility and entrainability demonstrated on real-time video with ultrasonography. PMID:27430001

  17. Musculoskeletal management of a patient with a history of chronic ankle sprains: identifying rupture of peroneal brevis and peroneal longus with diagnostic ultrasonography.

    PubMed

    Bruin, Dick B; von Piekartz, Harry

    2014-09-01

    The purpose of this case report is to describe the use of mobilization and eccentric exercise training for a patient with ankle pain and a history of chronic ankle sprains and discuss the course of diagnostic decision making when the patient did not respond to care. A 48-year-old police officer who had sustained multiple ankle sprains throughout his life presented with pain and restriction in his ability to walk, run, and work. The Global Rating of Change Scale score was - 6, the Numeric Pain Rating Scale score was 7/10, and the Lower Extremity Functional Scale score was - 33. Palpation of the peroneus longus and brevis muscles and inversion with overpressure reproduced the chief concern (Numeric Pain Rating Scale 7/10). The patient was initially diagnosed with chronic peroneal tendinopathy. Treatment included lateral translation mobilization of the talocrural joint combined with eccentric exercise using an elastic band for the peroneal muscles. The patient reported improvement in pain and function during the course of intervention but not as rapidly as expected. Therefore, follow-up ultrasonographic imaging and radiography were performed. These studies revealed partial rupture of the peroneal brevis muscle and total rupture of the peroneal longus muscle. A patient with long-term concerns of the foot complex with a diagnosis of peroneal tendinopathy showed slight improvement with eccentric exercises combined with manual therapy of the talocrural joint. After a course of treatment but minimal response, a diagnosis of tendon rupture was confirmed with diagnostic ultrasonography. Clinicians should be aware that when injuries do not improve with care, tendon rupture should be considered.

  18. Preoperative identification of a suspicious adnexal mass: a systematic review and meta-analysis.

    PubMed

    Dodge, Jason E; Covens, Allan L; Lacchetti, Christina; Elit, Laurie M; Le, Tien; Devries-Aboud, Michaela; Fung-Kee-Fung, Michael

    2012-07-01

    To systematically review the existing literature in order to determine the optimal strategy for preoperative identification of the adnexal mass suspicious for ovarian cancer. A review of all systematic reviews and guidelines published between 1999 and 2009 was conducted as a first step. After the identification of a 2004 AHRQ systematic review on the topic, searches of MEDLINE for studies published since 2004 was also conducted to update and supplement the evidentiary base. A bivariate, random-effects meta-regression model was used to produce summary estimates of sensitivity and specificity and to plot summary ROC curves with 95% confidence regions. Four meta-analyses and 53 primary studies were included in this review. The diagnostic performance of each technology was compared and contrasted based on the summary data on sensitivity and specificity obtained from the meta-analysis. Results suggest that 3D ultrasonography has both a higher sensitivity and specificity when compared to 2D ultrasound. Established morphological scoring systems also performed with respectable sensitivity and specificity, each with equivalent diagnostic competence. Explicit scoring systems did not perform as well as other diagnostic testing methods. Assessment of an adnexal mass by colour Doppler technology was neither as sensitive nor as specific as simple ultrasonography. Of the three imaging modalities considered, MRI appeared to perform the best, although results were not statistically different from CT. PET did not perform as well as either MRI or CT. The measurement of the CA-125 tumour marker appears to be less reliable than do other available assessment methods. The best available evidence was collected and included in this rigorous systematic review and meta-analysis. The abundant evidentiary base provided the context and direction for the diagnosis of early-staged ovarian cancer. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Diagnostic utility of carotid artery duplex ultrasonography in the evaluation of syncope: a good test ordered for the wrong reason.

    PubMed

    Kadian-Dodov, Daniella; Papolos, Alexander; Olin, Jeffrey W

    2015-06-01

    Syncope refers to a transient loss of consciousness and postural tone secondary to cerebral hypoperfusion. Guidelines recommend against neurovascular testing in cases of syncope without neurologic symptoms; however, many pursue carotid artery duplex ultrasonography (CUS) due to the prognostic implications of identified cerebrovascular disease. Our objective was to determine the diagnostic utility of CUS in the evaluation of syncope and the identification of new or severe atherosclerosis with the potential to change patient management. We reviewed records of 569 patients with CUS ordered for the primary indication of syncope through an accredited vascular laboratory at an academic, urban medical centre. Findings on CUS, patient demographic, clinical and laboratory information, and medications within 6 months of the CUS exam were reviewed. Bivariate relationships between key medical history characteristics and atherosclerosis status (known vs. new disease) were examined. Among 495 patients with complete information, cerebrovascular findings could potentially explain syncope in 2% (10 patients). Optimization of cardiovascular risk factors would benefit patients with known (56.6%) and new atherosclerosis (33.5%) with suboptimal lipid control, (LDL > 70 in 42.2 and 34.9% respectively; LDL > 100 in 15.7 and 20.4%), and those not on high-intensity statin therapy (80 and 87.5%) or antiplatelet medications (13.2 and 50.6%). CUS is a low-yield diagnostic test in the evaluation of syncope, but it is useful in the diagnosis of atherosclerosis and identification of subjects who would benefit from optimal medical therapy. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  20. Does this adult patient have a blunt intra-abdominal injury?

    PubMed

    Nishijima, Daniel K; Simel, David L; Wisner, David H; Holmes, James F

    2012-04-11

    Blunt abdominal trauma often presents a substantial diagnostic challenge. Well-informed clinical examination can identify patients who require further diagnostic evaluation for intra-abdominal injuries after blunt abdominal trauma. To systematically assess the precision and accuracy of symptoms, signs, laboratory tests, and bedside imaging studies to identify intra-abdominal injuries in patients with blunt abdominal trauma. We conducted a structured search of MEDLINE (1950-January 2012) and EMBASE (1980-January 2012) to identify English-language studies examining the identification of intra-abdominal injuries. A separate, structured search was conducted for studies evaluating bedside ultrasonography. We included studies of diagnostic accuracy for intra-abdominal injury that compared at least 1 finding with a reference standard of abdominal computed tomography, diagnostic peritoneal lavage, laparotomy, autopsy, and/or clinical course for intra-abdominal injury. Twelve studies on clinical findings and 22 studies on bedside ultrasonography met inclusion criteria for data extraction. Critical appraisal and data extraction were independently performed by 2 authors. The prevalence of intra-abdominal injury in adult emergency department patients with blunt abdominal trauma among all evidence level 1 and 2 studies was 13% (95% CI, 10%-17%), with 4.7% (95% CI, 2.5%-8.6%) requiring therapeutic surgery or angiographic embolization of injuries. The presence of a seat belt sign (likelihood ratio [LR] range, 5.6-9.9), rebound tenderness (LR, 6.5; 95% CI, 1.8-24), hypotension (LR, 5.2; 95% CI, 3.5-7.5), abdominal distention (LR, 3.8; 95% CI, 1.9-7.6), or guarding (LR, 3.7; 95% CI, 2.3-5.9) suggest an intra-abdominal injury. The absence of abdominal tenderness to palpation does not rule out an intra-abdominal injury (summary LR, 0.61; 95% CI, 0.46-0.80). The presence of intraperitoneal fluid or organ injury on bedside ultrasound assessment is more accurate than any history and physical examination findings (adjusted summary LR, 30; 95% CI, 20-46); conversely, a normal ultrasound result decreases the chance of injury detection (adjusted summary LR, 0.26; 95% CI, 0.19-0.34). Test results increasing the likelihood of intra-abdominal injury include a base deficit less than -6 mEq/L (LR, 18; 95% CI, 11-30), elevated liver transaminases (LR range, 2.5-5.2), hematuria (LR range, 3.7-4.1), anemia (LR range, 2.2-3.3), and abnormal chest radiograph (LR range, 2.5-3.8). Symptoms and signs may be most useful in combination, particularly in identification of patients who do not need further diagnostic workup. Bedside ultrasonography has the highest accuracy of all individual findings, but a normal result does not rule out an intra-abdominal injury. Combinations of clinical findings may be most useful to determine which patients do not require further evaluation, but the ideal combination of variables for identifying patients without intra-abdominal injury requires further study.

  1. Examination of products of conception terminated after prenatal investigation.

    PubMed Central

    Knowles, S

    1986-01-01

    A large number of district general hospitals have access to diagnostic ultrasonography and other methods of prenatal diagnosis, resulting in an increased supply of freshly terminated malformed fetuses to general histopathology departments, and there is now more open discussion of malformation and greater concern over fetal wastage. General pathologists are therefore under greater pressure to produce complete and detailed descriptions of a wide range of often complex anomalies. The dismissal of specimens as "multiple congenital anomalies" is becoming increasingly unacceptable to couples who wish to embark on further pregnancies and to their medical attendants. As in other fields an understanding of the methods and terminology in clinical use and a consistent diagnostic approach should help pathologists to extract sufficient information for accurate counselling. Images PMID:3537013

  2. Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis

    PubMed Central

    Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami

    2013-01-01

    AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754

  3. Transthoracic ultrasonography for the immunocompromised patient. A pilot project that introduces transthoracic ultrasonography for the follow-up of hematological patients in Romania.

    PubMed

    Frinc, Ioana; Ilies, Petru; Zaharie, Florin; Dima, Delia; Tanase, Alina; Petrov, Ljubomir; Irimie, Alexandru; Berce, Cristian; Lisencu, Cosmin; Berindan-Neagoe, Ioana; Tomuleasa, Ciprian; Bojan, Anca

    2017-06-01

    In the past decade, there has been significant progress in clinical hematology with the discovery of targeted molecules and thus the achievement of both hematologic and molecular responses. Nevertheless, chemotherapy remains the treatment of choice for many types of hematological malignancies. Aggressive chemotherapy leads to immunosuppression, accompanied by a high rate of infections and an increased rate of treatment-related mortality. Invasive fungal infections as well as more common bacterial and viral infections are frequent in immunocompromised patients as they are difficult to diagnose and treat. Pleuropulmonary infections in immunocompromised patients are diagnosed using clinical examination, imaging and laboratory tests. Many laboratory tests are run for several days before a final result is given and are expensive. Computer tomography is a reliable technique, but it is encumbered by high irradiation and high cost, and can assess lesions larger than 1 cm. Transthoracic ultrasound is a modern method, used in the diagnostic algorithm of pleuropulmonary pathology. It allows the diagnosis of small lesions, can be performed at the patients' bedside, with acceptable costs and no irradiation. A fast, informed and accurate medical decision is essential for a favorable outcome in immunosuppressed patients with an adjacent infection. In the current case series we present the implementation of a new protocol for the follow-up of immunocompromised patients using transthoracic ultrasonography, of great potential use in the clinic.

  4. Ultrasonographic evaluation of abdominal distension in 52 camels (Camelus dromedarius).

    PubMed

    Tharwat, Mohamed; Al-Sobayil, Fahd; Ali, Ahmed; Buczinski, Sébastien

    2012-08-01

    The purpose of this study was to assess the diagnostic value of ultrasonography in the evaluation of abdominal distension in 52 camels (Camelus dromedarius). The conditions included trypanosomiasis (n=35), intestinal obstruction (n=12) and ruptured urinary bladder (n=5). Fifteen clinically normal camels were included as controls. Transabdominal and transrectal ultrasonography was carried out on all camels. In animals with trypanosomiasis, ultrasonographic findings included accumulation of massive amounts of hypoechoic abdominal fluids where liver, intestine, kidney, spleen and urinary bladder were imaged floating. Except in two cases of bile duct calcification and one of hepatic abscessation, no detectable abnormal sonographic lesions were detected while imaging the hepatic and renal parenchyma, and the heart and its valves and major blood vessels. In camels with intestinal obstruction, ultrasonographic findings included distended intestinal loops with markedly reduced or absent motility. In one camel, the intestinal lumen contained localised hyperechoic material that was consistent with a foreign body. Hypoechoic fluid with or without fibrin was seen between intestinal loops. In camels with ruptured urinary bladder, ultrasonographic findings included collapsed and perforated bladder, echogenic blood clots within the urinary bladder and peritoneal cavity, increased thickness of the bladder wall, floating intestines in hypoechogenic fluid and echogenic calculi within the urethra. Ultrasonography was considered a useful tool for the evaluation of dromedary camels with abdominal distension. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification.

    PubMed

    Lee, Dong Ho

    2017-12-01

    Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method.

  6. Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification

    PubMed Central

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method. PMID:28994271

  7. Return to contact sports following infectious mononucleosis: the role of serial ultrasonography.

    PubMed

    O'Connor, Tony E; Skinner, Liam J; Kiely, Patrick; Fenton, John E

    2011-08-01

    Splenic rupture is a rare but potentially fatal complication of infectious mononucleosis. Athletes returning to contact sports following infectious mononucleosis are at potential risk of splenic rupture secondary to abdominal trauma. No clear consensus exists as to when it is safe to allow these athletes to return to contact sports. Suggested periods of abstinence have ranged from 2 weeks to 6 months. We outline our experiences with the use of abdominal ultrasonography at 1 month after the diagnosis of infectious mononucleosis as a means of determining when athletes can safely return to contact sports. Our study group was made up of 19 such patients (mean age: 16.7 yr). We found that 16 of these patients (84%) had normal splenic dimensions on ultrasonography 1 month after diagnosis, and they were therefore allowed to return to contact sports. While the remaining 3 patients had an enlarged spleen at 1 month, their splenic dimensions had all returned to normal when ultrasonographic examination was repeated at 2 months postdiagnosis. We conclude that serial abdominal ultrasonography allows for informed decision making in determining when athletes can safely return to contact sports following infectious mononucleosis.

  8. Point-of-care ultrasonography as a training milestone for internal medicine residents: the time is now.

    PubMed

    Sabath, Bruce F; Singh, Gurkeerat

    2016-01-01

    Point-of-care (POC) ultrasonography is considered fundamental in emergency medicine training and recently has become a milestone in critical care fellowship programs as well. Currently, there is no such standard requirement for internal medicine residency programs in the United States. We present a new case and briefly review another case at our institution - a community hospital - in which internal medicine house staff trained in ultrasonography were able to uncover unexpected and critical diagnoses that significantly changed patient care and outcomes. We also review the growing evidence of the application of ultrasound in the diagnosis of a myriad of conditions encountered in general internal medicine as well as the mounting data on the ability of internal medicine residents to apply this technology accurately at the bedside. We advocate that the literature has sufficiently established the role of POC ultrasonography in general internal medicine that there should no longer be any delay in giving this an official place in the development of internal medicine trainees. This may be particularly useful in the community hospital setting where 24-h echocardiography or other sonography may not be readily available.

  9. Ultrasonographic patterns in patients with obstructed defaecation.

    PubMed

    Brusciano, L; Limongelli, P; Pescatori, M; Napolitano, V; Gagliardi, G; Maffettone, V; Rossetti, G; del Genio, G; Russo, G; Pizza, F; del Genio, A

    2007-08-01

    Anal ultrasound is helpful in assessing organic anorectal lesions, but its role in functional disease is still questionable. The purpose of the present study is to assess anal-vaginal-dynamic perineal ultrasonographic findings in patients with obstructed defecation (OD) and healthy controls. Ninety-two consecutive patients (77 women; mean age 51 years; range 21-71) with symptoms of OD were retrospectively evaluated. All patients underwent digital exploration, endoanal and endovaginal ultrasound (US) with rotating probe. Forty-one patients underwent dynamic perineal US with linear probe. Anal manometry and defaecography were performed in 73 and 43 patients, respectively. Ultrasonographic findings of 92 patients with symptoms of OD were compared to 22 healthy controls. Anismus was defined on US when the difference in millimetres between the distance of the inner edge of the puborectalis muscle posteriorly and the probe at rest and on straining was less then 5 mm. Sensitivity and specificity were calculated by assuming defaecography as the gold standard for intussusception and rectocele and proctoscopy for rectal internal mucosal prolapse. Since no gold standard for the diagnosis of anismus was available in the literature, the agreement between anal US and all other diagnostic procedures was evaluated. The incidence of anismus resulted significantly higher (P < 0.05) in OD patients than healthy controls on anal (48 vs 22%), vaginal (44 vs 21%), and dynamic perineal US (53 vs 22%). A significantly higher incidence of rectal internal mucosal prolapse was observed in OD patients when compared to healthy controls on both anal (61.9 vs 13.6%, P < 0.0001) and dynamic perineal US (51.2 vs.9% P = 0.001). For the diagnosis of rectal internal mucosal prolapse, anal US had a 100% sensitivity and specificity. For diagnosis of rectal intussusception, anal US had an 83.3% sensitivity and 100% specificity and perineal US had a 66.6% sensitivity and 100% specificity. In the diagnosis of anismus, anal ultrasonography resulted in agreement with perineal and vaginal US, manometry, defaecography, and digital exam (P < 0.05). Other lesions detected by US in patients with OD include solitary rectal ulcer, rectocele and enterocele. Damage of internal and/or external sphincter was diagnosed at anal US in 19/92 (20%) patients, all continent and with normal manometric values. Anal, vaginal and dynamic perineal ultrasonography can diagnose or confirm many of the abnormalities seen in patients with OD. The value of the information obtained by this non-invasive test and its role in the diagnostic algorithm of OD is yet to be defined.

  10. Primary and secondary prevention of breast cancer.

    PubMed

    Kolak, Agnieszka; Kamińska, Marzena; Sygit, Katarzyna; Budny, Agnieszka; Surdyka, Dariusz; Kukiełka-Budny, Bożena; Burdan, Franciszek

    2017-12-23

    Breast cancer is the most common cancer among women and is the second cancer frequently occurring worldwide of newly-diagnosed cancers. There is much evidence showing the influence of life style and environmental factors on the development of mammary gland cancer (high-fat diet, alcohol consumption, lack of physical exercise), the elimination of which (primary prevention) may contribute to a decrease in morbidity and mortality. Secondary prevention, comprising diagnostic tests (e.g. mammography, ultrasonography, magnetic resonance imaging, breast self-examination, as well as modern and more precise imaging methods) help the early detection of tumours or lesions predisposing to tumours. The aim of this study paper is to review current knowledge and reports regarding primary and secondary prevention of breast cancer. It is estimated that nearly 70% of malign tumours are caused by environmental factors, whereas in breast cancer this percentage reaches 90-95%. There are national programmes established in many countries to fight cancer, where both types of prevention are stressed as serving to decrease morbidity and mortality due to cancers. Cancer prevention is currently playing a key role in the fight against the disease. Behaviour modification, as well as greater awareness among women regarding breast cancer, may significantly contribute towards reducing the incidence of this cancer. Another important aspect is the number of women undergoing diagnostic tests, which still remains at an unsatisfactory level.

  11. Preoperative predictive factors for gallbladder cholesterol polyp diagnosed after laparoscopic cholecystectomy for polypoid lesions of gallbladder

    PubMed Central

    Lee, Hyojin; Park, Inseok; Cho, Hyunjin; Gwak, Geumhee; Yang, Keunho; Bae, Byung-Noe; Kim, Hong-Ju; Kim, Young Duk

    2016-01-01

    Backgrounds/Aims We investigated patients' clinical and radiological data to determine preoperative factors that predict cholesterol gallbladder (GB) polyps of large size, which can be helpful for decision on further diagnostic tools. Methods In this study, we retrospectively analyzed 126 patients who underwent laparoscopic cholecystectomy for GB polyps >10 mm diagnosed preoperatively by abdominal ultrasonography between February 2002 and February 2016 in Department of Surgery, Sanggye Paik Hospital. Patients were divided into non-cholesterol polyps group and cholesterol polyps group, based on the postoperative pathologic diagnosis. Clinical and radiological data, such as gender, age, body weight, height, body mass index (BMI), laboratory findings, size, number and shape of the polypoid lesions, and presence of the concurrent GB stone were compared between the two groups. Results Of the 126 cases, 73 had cholesterol polyps (57.9%) and 53 cases were non-cholesterol polyps (42.1%). The younger age (<48.5 years), size of polyp <13.25 mm and multiple polyps were independent predictive variables for cholesterol polyps, with odd ratios (OR) of 2.352 (p=0.045), 5.429 (p<0.001) and 0.472 (p<0.001), respectively. Conclusions Age, size and polyp number were used to predict cholesterol GB polyp among polypoid lesions of the gallbladder >10 mm. For cases in which these factors are not applicable, it is strongly recommended to evaluate further diagnostic tools, such as computed tomography, endoscopic ultrasonography and tumor markers. PMID:28261697

  12. Contrast-enhanced color Doppler ultrasonography increases diagnostic accuracy for soft tissue tumors.

    PubMed

    Oebisu, Naoto; Hoshi, Manabu; Ieguchi, Makoto; Takada, Jun; Iwai, Tadashi; Ohsawa, Masahiko; Nakamura, Hiroaki

    2014-10-01

    Resolution of ultrasonography (US) has undergone marked development. Additionally, a new-generation contrast medium (Sonazoid) used for US is newly available. Contrast-enhanced US has been widely used for evaluating several types of cancer. In the present study, we evaluated the ability of color Doppler US (CDUS) and Sonazoid to differentiate between benign and malignant soft tissue tumors. A total of 180 patients (87 male, 93 female) were enrolled in the present study. The patient ages ranged from 1 to 91 years (mean 58.1±20.0 years). The maximum size, depth, tumor margins, shape, echogenicity and textural pattern were measured on gray-scale images. CDUS was used to evaluate the intratumoral blood flow with and without Sonazoid. Peak systolic flow velocity (Vp), mean flow velocity (Vm), resistivity index (RI) and pulsatility index (PI) of each detected intratumoral artery were automatically calculated with power Doppler US (PDUS). The present study included 118 benign and 62 malignant tumors. Statistical significances were found in size, depth, tumor margin and textural pattern but not in shape or echogenicity on gray-scale images. Before Sonazoid injection, CDUS findings showed 55% sensitivity, 77% specificity and 69% accuracy, whereas contrast-enhanced CDUS showed 87% sensitivity, 68% specificity and 74% accuracy. There were no statistically significant differences between malignant and benign tumors regarding the mean Vp, Vm, RI and PI values determined on PDUS. In conclusion, contrast-enhanced CDUS proved to be a reliable diagnostic tool for detecting malignant potential in soft tissue tumors.

  13. Establishment of ultrasound as a diagnostic aid in the referral of patients with abdominal pain in an emergency department – a pilot study

    PubMed Central

    Poulsen, Liv la Cour; Bækgaard, Emilie Stokholm; Istre, Per Grosen; Schmidt, Thomas Andersen; Larsen, Torben

    2015-01-01

    Purpose Ultrasonography is a noninvasive, cheap, and fast way of assessing abdominal pain in an emergency department. Many physicians working in emergency departments do not have pre-existing ultrasound experience. The purpose of this study was to investigate the ability of first-year internship doctors to perform a reliable ultrasound examination on patients with abdominal pain in an emergency setting. Materials and methods This study took place in an emergency department in Denmark. Following a 1-day ultrasound introduction course, three doctors without prior ultrasound experience scanned 45 patients during a 2-month period. The applicability of the examinations was evaluated by subsequent control examination: computed tomography, operation, or ultrasound by a trained radiologist or gynecologist or, in cases where the patient was immediately discharged, by ultrasound image evaluation. Results In 14 out of 21 patients with a control examination, there was diagnostic agreement between the project ultrasound examination and the control. Image evaluation of all patients showed useful images of the gallbladder, kidneys, liver, abdominal aorta, and urinary bladder, but no useful images for either the pancreas or colon. Conclusion With only little formal training, it is possible for first-year internship doctors to correctly visualize some abdominal organs with ultrasonography. However, a longer study time frame, including more patients, and an ultrasound course specifically designed for the purpose of use in an emergency department, is needed to enhance the results. PMID:27147884

  14. [Differential echographic diagnosis in small tissue areas--exemplified by the orbits].

    PubMed

    Buschmann, W; Haigis, W

    1982-12-01

    Measurement-based ultrasonography proved mandatory in ophthalmic diagnostic work. It provides comparable examination conditions and therefore, comparable results, in contrast to simple, empirical ultrasonic examination. Measurement methods which can be easily applied under clinical conditions have been developed for determination of those technical characteristics of the apparatus and transducer probes which proved decisive for the diagnostic results. Some echographic criteria can be additionally or better evaluated using this basis. All echo-amplitude measurements should be related to a well-defined test-reflector echo. In addition to sensitivity and resolution, frequency and frequency spectrum are especially important. Manufacturer's data have proved insufficient up to now, insufficient; even within one manufacturer's series of one equipment or transducer probe type considerable deviations from the declared data have been found. Such deviations may mimick pathologic alterations in the echograms. The size of a lesion area can be better evaluated when using well-defined technical conditions. The echographic presentation of tissue structures in the depth is especially dependent on frequency and on the frequency spectrum. Pathologic alterations of tissues may cause changes in the ultrasound attenuation which results in emphasized or reduced presentation of echoes from normal structures behind the lesion area. Tissue differentiation should be based on additional A-scan echograms. Computerized echogram averaging provides a more reliable evaluation of echo amplitudes and ultrasound attenuation. Use of measurement-based ultrasonography permits to compare measured echo-amplitudes and ultrasound attenuation with the results of other working groups, even if these are based on other equipment and transducers.

  15. Comparison of transvaginal ultrasound and saline contrast sonohysterography in evaluation of cesarean scar defect. A prospective cohort study.

    PubMed

    Antila-Långsjö, Riitta; Mäenpää, Johanna U; Huhtala, Heini; Tomás, Eija; Staff, Synnöve

    2018-05-12

    The aim of this study was to investigate the prevalence of post-cesarean isthmocele and to measure agreement between transvaginal ultrasonography and saline contrast sonohysterography in assessment of isthmocele. Prospective observational cohort study was carried out at Tampere University Hospital, Finland. Non-pregnant women delivered by cesarean section (n=371) were examined with transvaginal ultrasonography (TVUS) and sonohysterography (SHG) six months after cesarean section. The main outcome measure was the prevalence of isthmocele using TVUS and SHG. Secondary outcome measures were characteristics of isthmocele. Three hundred and seventy-one women were included. The prevalence of isthmocele was 22.4% based on TVUS and 45.6% based on SHG. Sensitivity and specificity for TVUS was 49.1 and 100% when compared to SHG. Therefore, half of the defects (50.9%) diagnosed with SHG remained undiagnosed with TVUS. Bland-Altman analysis showed an underestimation of 1.1 mm (range 0.00 to 7.90) for TVUS compared to SHG, with 95% limits of agreement from -1.9 to 4.1 mm. This methodological study provides confirmatory data that TVUS and SHG are not in good agreement in the isthmocele diagnostics and the use of only TVUS may lead to an underestimation of the prevalence of isthmocele. Thus, SHG should be considered as a method of choice in diagnostics of isthmocele. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  16. [Physiology and pathology of reproduction in domesticated New World camelids with special emphasis on ultrasonography].

    PubMed

    Hoops, M; Kauffold, J

    2013-01-01

    The number of New World camelids in Germany is increasing. Owners and breeders are usually well educated regarding their animals. For practitioners, this means being up-to-date with respect to their veterinary knowledge. This includes the physiology and pathology of reproduction. Specifics of reproduction in domesticated New World camelids are an induced ovulation, the absence of cyclic sexual activity, a relatively long gestation of 336-349 days and a predominantly left-horn gestation. Ultrasonography plays an important role as part of the gynecological examination. Generally, the ultrasonographic examination can be performed transrectally and transcutaneously in the left or right flanks. Transrectal ultrasonography has to be carried out with particular caution to avoid rectal injuries. An accurate pregnancy diagnosis by transrectal scanning is possible starting from day 20 of pregnancy; using transcutaneous scanning, diagnosis is accurate starting on days 50-60 (left flank) or from day 90 (right flank) of pregnancy, respectively. Ultrasonography is also appropriate to examine the non-gravid uterus and the ovaries. Based on 5 years of experience working with farmed New World camelids, the article describes the physiology and pathology of reproduction in domesticated New World camelids. Particular consideration is given to the ultrasonographical examination of the genital organs.

  17. The role of ultrasonography in the management of lung and pleural diseases.

    PubMed

    Rumende, C Martin

    2012-04-01

    Ultrasonographic examination in pulmonology provides a revolutionary advance because it is very helpful in the diagnosis and management of various pleural and peripheral pulmonary defects. Lung ultrasonography allows the clinicians to diagnose some pulmonary abnormalities more rapidly, including the diagnosis of pleural effusion. Ultrasound examination also provides great assistance for the clinicians to perform invasive techniques in the field of pulmonology, which may increase the success rate and reduce the likelihood of complications. In addition to pleural effusion, other lung disorders can be diagnosed by ultrasound such as peripheral lung tumors and other pleural abnormalities caused by pleural fibrosis and tumor metastasis as well as the primary pleural tumor (mesothelioma). Ultrasound-guided invasive procedures include aspiration of minimal effusion, Transthoracal Needle Aspiration, Transthoracal biopsies and chest tube insertion. Lung ultrasound also offers other advantages, i.e. free from radiation hazards, portable, non-invasive and relatively inexpensive. Ultrasonography in the thorax also has its limitations, especially in detecting mediastinal abnormalities.

  18. The role of transvaginal power Doppler ultrasound in the differential diagnosis of benign intrauterine focal lesions.

    PubMed

    Cogendez, Ebru; Eken, Meryem Kurek; Bakal, Nuray; Gun, Ismet; Kaygusuz, Ecmel Isik; Karateke, Ates

    2015-10-01

    The purpose of this prospective study was to assess the role of power Doppler imaging in the differential diagnosis of benign intrauterine focal lesions such as endometrial polyps and submucous myomas using the characteristics of power Doppler flow mapping. A total of 480 premenopausal patients with abnormal uterine bleeding were evaluated by transvaginal ultrasonography (TVS) searching for intrauterine pathology. Sixty-four patients with a suspicious focal endometrial lesion received saline infusion sonography (SIS) after TVS. Fifty-eight patients with focal endometrial lesions underwent power Doppler ultrasound (PDUS). Three different vascular flow patterns were defined: Single vessel pattern, multiple vessel pattern, and circular flow pattern. Finally, hysteroscopic resection was performed in all cases, and Doppler flow characteristics were then compared with the final histopathological findings. Histopathological results were as follows: endometrial polyp: 40 (69 %), submucous myoma: 18 (31 %). Of the cases with endometrial polyps, 80 % demonstrated a single vessel pattern, 7.5 % a multiple vessel pattern, and 0 % a circular pattern. Vascularization was not observed in 12.5 % of patients with polyps. Of the cases with submucousal myomas, 72.2 % demonstrated a circular flow pattern, 27.8 % a multiple vessel pattern, and none of them showed a single vessel pattern. The sensitivity, specificity, and positive and negative predictive values of the single vessel pattern in diagnosing endometrial polyps were 80, 100, 100, and 69.2 %, respectively; and for the circular pattern in diagnosing submucous myoma, these were 72.2, 100, 100, and 88.9 %, respectively. Power Doppler blood flow mapping is a useful, practical, and noninvasive diagnostic method for the differential diagnosis of benign intrauterine focal lesions. Especially in cases of recurrent abnormal uterine bleeding, recurrent abortion, and infertility, PDUS can be preferred as a first-line diagnostic method.

  19. Imaging of female infertility: a pictorial guide to the hysterosalpingography, ultrasonography, and magnetic resonance imaging findings of the congenital and acquired causes of female infertility.

    PubMed

    Kaproth-Joslin, Katherine; Dogra, Vikram

    2013-11-01

    Hysterosalpingography is the gold standard in assessing the patency of the fallopian tubes, which is among the most common causes of female factor infertility, making this technique the most frequent first-choice imaging modality in the assessment of female infertility. Ultrasonography and magnetic resonance imaging are typically used for evaluation of indeterminate or complicated cases of female infertility and presurgical planning. Imaging also plays a role in the detection of the secondary causes of ovarian factor infertility, including endometriosis and polycystic ovarian syndrome. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.

    PubMed

    Stengel, Dirk; Bauwens, Kai; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas

    2013-07-31

    Ultrasonography is regarded as the tool of choice for early diagnostic investigations in patients with suspected blunt abdominal trauma. Although its sensitivity is too low for definite exclusion of abdominal organ injury, proponents of ultrasound argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of computed tomography scans and cut costs. To assess the effects of trauma algorithms that include ultrasound examinations in patients with suspected blunt abdominal trauma. We searched the Cochrane Injuries Group's Specialised Register, CENTRAL (The Cochrane Library), MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL (EBSCO), publishers' databases, controlled trials registers and the Internet. Bibliographies of identified articles and conference abstracts were searched for further elligible studies. Trial authors were contacted for further information and individual patient data. The searches were updated in February 2013. randomised controlled trials (RCTs) and quasi-randomised trials (qRCTs). patients with blunt torso, abdominal or multiple trauma undergoing diagnostic investigations for abdominal organ injury. diagnostic algorithms comprising emergency ultrasonography (US). diagnostic algorithms without ultrasound examinations (for example, primary computed tomography [CT] or diagnostic peritoneal lavage [DPL]). mortality, use of CT and DPL, cost-effectiveness, laparotomy and negative laparotomy rates, delayed diagnoses, and quality of life. Two authors independently selected trials for inclusion, assessed methodological quality and extracted data. Where possible, data were pooled and relative risks (RRs), risk differences (RDs) and weighted mean differences, each with 95% confidence intervals (CIs), were calculated by fixed- or random-effects modelling, as appropriate. We identified four studies meeting our inclusion criteria. Overall, trials were of moderate methodological quality. Few trial authors responded to our written inquiries seeking to resolve controversial issues and to obtain individual patient data. We pooled mortality data from three trials involving 1254 patients; relative risk in favour of the US arm was 1.00 (95% CI 0.50 to 2.00). US-based pathways significantly reduced the number of CT scans (random-effects RD -0.52, 95% CI -0.83 to -0.21), but the meaning of this result is unclear. Given the low sensitivity of ultrasound, the reduction in CT scans may either translate to a number needed to treat or number needed to harm of two. There is currently insufficient evidence from RCTs to justify promotion of ultrasound-based clinical pathways in diagnosing patients with suspected blunt abdominal trauma.

  1. Oxidant/antioxidant status in lambs and sheep with liver and lung cystic echinococcosis diagnosed by ultrasonography and necropsy.

    PubMed

    Sagkan-Ozturk, A; Durgut, R; Ozturk, O H

    2015-03-15

    The aim of this study was to evaluate total antioxidant capacity (TAC), total oxidant status (TOS), and oxidative stress index (OSI) in sheep and lambs with cyctic eccinocoocosis (CE) diagnosed by ultrasonography and necropsy findings. A total of 9 sheep and 17 lambs with CE were used in this study and the findings were compared to those of 6 healthy control sheep. Ultrasonography were used for the diagnosis of CE in sheep and lambs, and necropsy was performed to check the presence of cysts in liver and lungs. Serum TOS and TAC were measured by a novel colorimetric method. The TOS-to-TAC ratios were also calculated as OSI values. Serum biochemical profiles were determined by conventional measurement methods as well. The mean values for TOS, TAC and OSI were significantly (p<0.001) lower in sheep and lambs with CE when compared with those of the control sheep, and they were also significantly lower in lambs with CE in comparison to the mean values obtained in sheep with CE. The levels of serum albumin, total cholesterol, creatinine, and triglycerides in lambs with CE were found out to decrease significantly (p<0.001) when compared with those of both sheep with EC and the control group. There were no significant differences between the groups in terms of other serum parameters. In addition, when clinically and some biochemical values were evaluated, CE was found to be more severe in lambs than in sheep. It was concluded that although common diagnostic cyst detection is performed by postmortem examination, ultrasonography could successfully be used in conjunction with serum biochemical profile detection and serum TOS, TAC and OSI measurements for diagnosis of cysts in liver and lungs of severely infected living sheep and lambs. Serum albumin, total cholesterol, creatinine, total protein and triglycerides might be used as indicators in sheep and particularly in lambs for the diagnosis of CE. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Imaging for Polyps and Leiomyomas in Women With Abnormal Uterine Bleeding: A Systematic Review.

    PubMed

    Maheux-Lacroix, Sarah; Li, Fiona; Laberge, Philippe Y; Abbott, Jason

    2016-12-01

    To evaluate the accuracy of saline infusion sonohysterography in comparison with transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. We searched the databases MEDLINE, EMBASE, CENTRAL, and ClinicalTrials.gov as well as citations and reference lists to the end of November 2015. Two authors screened 5,347 citations for eligibility. We included randomized controlled trials or prospective cohort studies published in English, assessing the accuracy of saline infusion sonohysterography and transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. We considered studies using histopathologic specimens obtained at either hysteroscopy or hysterectomy as criterion standard. Twenty-five studies were eligible. Two authors extracted data and assessed the quality of included studies. Bivariate random-effects models were used to compare the different tests and evaluate sources of heterogeneity. Saline infusion sonohysterography was superior to transvaginal ultrasonography with pooled sensitivity and specificity of 0.92 and 0.89 compared with 0.64 and 0.90, respectively (P<.001). Transvaginal ultrasound sensitivity for diagnosing polyps was particularly low (0.51). Saline infusion sonohysterography was also compared with hysteroscopy in seven studies and had similar sensitivity but inferior specificity (0.93 and 0.83 compared with 0.95 and 0.90, respectively, P=.007). All three procedures were well-tolerated by women. Saline infusion sonohysterography was successfully completed in 95% of women. Technical variations such as the use of balloon catheters were not found to affect diagnostic accuracy. Transvaginal ultrasonography lacks sensitivity to be used alone to exclude the presence of polyps and leiomyomas in women with abnormal uterine bleeding. Although less specific than hysteroscopy, saline infusion sonohysterography offers a similar detection rate and permits concomitant visualization of the ovaries and myometrium. Cost, convenience, and tolerability of different imaging techniques require further evaluation. PROSPERO International prospective register of systematic reviews, http://www.crd.york.ac.uk/PROSPERO, CRD42016034005.

  3. Performance analysis of medical video streaming over mobile WiMAX.

    PubMed

    Alinejad, Ali; Philip, N; Istepanian, R H

    2010-01-01

    Wireless medical ultrasound streaming is considered one of the emerging application within the broadband mobile healthcare domain. These applications are considered as bandwidth demanding services that required high data rates with acceptable diagnostic quality of the transmitted medical images. In this paper, we present the performance analysis of a medical ultrasound video streaming acquired via special robotic ultrasonography system over emulated WiMAX wireless network. The experimental set-up of this application is described together with the performance of the relevant medical quality of service (m-QoS) metrics.

  4. Variations of ultrasonic anatomy of the hepatic veins within the human liver.

    PubMed

    Lamanna, I; Bilić, A; Ljubicić, N; Bakula, B

    1990-01-01

    The aim of this study was to investigate various physiological variations of the hepatic veins within the liver of the 60 healthy subjects. All participants required physical examinations, different laboratory tests and upper abdominal ultrasonogram--all completely normal. Demonstration of the hepatic veins have been performed on sector real-time systems. The results clearly demonstrated that the physiological variations of the hepatic veins are very common. Ultrasonography obviously represents a diagnostic method of choice in the evaluation of anatomy of the hepatic venous system.

  5. Laryngeal juvenile xanthogranuloma: Imaging finding.

    PubMed

    Wang, L M; Chen, Q H; Zhang, Y X; Fang, Y Q

    2010-08-01

    Laryngeal juvenile xanthogranuloma is rare and there were only four cases have been reported previously in English literature. We report a case of isolated JXG of larynx in the superglottic region. The mass was well-defined and homogeneous hypoechoic in ultrasonography while presented indistinct boundary and soft tissue density in Computed Tomography images. Radiological findings are nonspecific but could help to understand the extent of the lesion. We suggest that JXG should be considered as differential diagnosis for laryngeal stridor. Laryngeal ultrasound is safe and reliable, which could be considered a useful diagnostic tool for supplementing laryngoscopy.

  6. Double valvular insufficiency in a Burmese python (Python molurus bivittatus, Linnaeus, 1758) suffering from concomitant bacterial pneumonia.

    PubMed

    Schilliger, Lionel; Tréhiou-Sechi, Emilie; Petit, Amandine M P; Misbach, Charlotte; Chetboul, Valérie

    2010-12-01

    Ultrasonography, and, to a lesser extent, echocardiography are now well-established, noninvasive, and painless diagnostic tools in herpetologic medicine. Various cardiac lesions have been previously described in reptiles, but valvulopathy is rarely documented in these animals and, consequently, is poorly understood. In this report, sinoatrial and atrioventricular insufficiencies were diagnosed in a 5-yr-old captive dyspneic Burmese python (Python molurus bivittatus) on the basis of echocardiographic and Doppler examination. This case report is the first to document Doppler assessment of valvular regurgitations in a reptile.

  7. Juvenile recurrent parotitis in children: diagnosis and treatment using sialography.

    PubMed

    Narsimha Rao, Vanga V; Putta Buddi, Jai Shankar Homberhali; Kurthukoti, Ameet J

    2014-01-01

    Juvenile recurrent parotitis (JRP) is a nonobstructive, nonsuppurative parotid inflammation in young children. Causative factors are many such as allergy, infection, local autoimmune manifestations, and genetic inheritance have been suggested, but none have been proved. Parotid sialography is a hallmark in the diagnosis of JRP but newer modalities such as ultrasonography, computed tomography and magnetic resonance imaging-sialography are noninvasive investigative techniques. Recurrent attacks are often managed conservatively. Here we report a case of a 5-year-old child with JRP. Sailography can be used as both diagnostic and therapeutic modality.

  8. Waterborne Pathogens: The Protozoans.

    PubMed

    Moss, Joseph Anthony

    2016-09-01

    Waterborne diseases associated with polluted recreational and potable waters have been documented for more than a century. Key microbial protozoan parasites, such as Cryptosporidium and Giardia, are causative agents for gastrointestinal disease worldwide. Although not a first-line diagnostic approach for these diseases, medical imaging, such as radiography, computed tomography, magnetic resonance imaging, ultrasonography, and nuclear medicine technologies, can be used to evaluate patients with long-term effects. This article describes protozoan pathogens that affect human health, treatment of common waterborne pathogen-related diseases, and associated medical imaging. ©2016 American Society of Radiologic Technologists.

  9. The clinical diagnosis of splenomegaly.

    PubMed Central

    Yang, J. C.; Rickman, L. S.; Bosser, S. K.

    1991-01-01

    Assessing for the presence of splenomegaly is an important component of the physical examination. Although several methods of palpation and percussion of the spleen have been described, until recently they have not been validated by noninvasive imaging techniques such as ultrasonography, radionuclide scanning, and computed tomography that offer objective means to assess splenomegaly. We review the literature comparing various physical examination techniques with noninvasive imaging modalities and conclude that palpation and percussion of the spleen are complementary but frequently insensitive and that further studies are needed to evaluate the efficacy of specific diagnostic methods. PMID:1877230

  10. Role of endoscopic ultrasonography in the staging and follow-up of esophageal cancer.

    PubMed

    Lightdale, Charles J; Kulkarni, Ketan G

    2005-07-10

    To evaluate the role of endoscopic ultrasonography (EUS) in the initial staging and follow-up of esophageal cancer on the basis of a review of the published literature. Articles published from 1985 to 2005 were searched and reviewed using the following keywords: "esophageal cancer staging," "endoscopic ultrasound," and "endoscopic ultrasonography." For initial anatomic staging, EUS results have consistently shown more than 80% accuracy compared with surgical pathology for depth of tumor invasion (T). Accuracy increased with higher stage, and was >90% for T3 cancer. EUS results have shown accuracy in the range of 75% for initial staging of regional lymph nodes (N). EUS has been invariably more accurate than computed tomography for T and N staging. EUS is limited for staging distant metastases (M), and therefore EUS is usually performed after a body imaging modality such as computed tomography or positron emission tomography. Pathologic staging can be achieved at EUS using fine-needle aspiration (FNA) to obtain cytology from suspect Ns. FNA has had greatest efficacy in confirming celiac axis lymph node metastases with more than 90% accuracy. EUS is inaccurate for staging after radiation and chemotherapy because of inability to distinguish inflammation and fibrosis from residual cancer, but a more than 50% decrease in tumor cross-sectional area or diameter has been found to correlate with treatment response. EUS has a central role in the initial anatomic staging of esophageal cancer because of its high accuracy in determining the extent of locoregional disease. EUS is inaccurate for staging after radiation therapy and chemotherapy, but can be useful in assessing treatment response.

  11. Role of B-scan ultrasonography in pre-operative cataract patients.

    PubMed

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  12. Applications of diagnostic ultrasonography in small ruminant reproductive management.

    PubMed

    Scott, P R

    2012-02-01

    Modern portable ultrasound machines provide the veterinary clinician with an inexpensive and non-invasive method to further examine the reproductive tract of both male and female sheep on farm which should take no more than 5 min with the results available immediately. Unlike cattle, ultrasound examination of the ovaries is not undertaken because failure to cycle during the normal season is rare in sheep and there are no common ovarian conditions causing acyclicity. Accurate diagnosis of foetal number has greatly improved the nutritional management of late gestation ewes over the past 30 years. Late gestation nutritional supply in response to foetal demand greatly reduces perinatal lamb mortality by ensuring lamb birthweight and ewe colostrum accumulation. The contents of vaginal prolapse have been determined using ultrasonography which has led to an improved method for correction. A retained foetus when second stage labour is considered to have been completed, and uterine torsion, can be identified during ultrasound examination allowing timely correction. Ultrasonographic examination of palpable scrotal abnormalities can provide much useful information particularly in the diagnosis of epididymitis, orchitis and testicular atrophy. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Incidental Fetal Ultrasound Findings: Interpretation and Management.

    PubMed

    Kaplan, Rebekah; Adams, Sharon

    2018-05-01

    Ultrasonography is a common component of prenatal care worldwide and is often used in early pregnancy to determine gestational age, number of fetuses, fetal cardiac activity, and placental location. Patients and their families may also consider ultrasonography a social event, as it provides confirmation and reassurance of a normal pregnancy. Ultrasound screening is typically scheduled in the second trimester to visualize fetal anatomy and confirm gestational age. Most ultrasound examinations are reassuring, but some incidentally identify structural anomalies and soft markers for aneuploidy, making it necessary for health care providers to correctly interpret these findings. The health care provider's ability to prepare patients prior to the ultrasound and deliver the necessary information needed to make informed decisions regarding any follow-up screening or diagnostic testing is critical to reducing parental anxiety. Preparation for the anatomic survey should include counseling for normal and abnormal findings. The ethical concepts of patient autonomy and shared decision making are used as a guide in providing this critical information and enabling informed choices during follow-up for incidental ultrasound findings. © 2018 by the American College of Nurse-Midwives.

  14. Cardiac ultrasonography over 4G wireless networks using a tele-operated robot

    PubMed Central

    Panayides, Andreas S.; Jossif, Antonis P.; Christoforou, Eftychios G.; Vieyres, Pierre; Novales, Cyril; Voskarides, Sotos; Pattichis, Constantinos S.

    2016-01-01

    This Letter proposes an end-to-end mobile tele-echography platform using a portable robot for remote cardiac ultrasonography. Performance evaluation investigates the capacity of long-term evolution (LTE) wireless networks to facilitate responsive robot tele-manipulation and real-time ultrasound video streaming that qualifies for clinical practice. Within this context, a thorough video coding standards comparison for cardiac ultrasound applications is performed, using a data set of ten ultrasound videos. Both objective and subjective (clinical) video quality assessment demonstrate that H.264/AVC and high efficiency video coding standards can achieve diagnostically-lossless video quality at bitrates well within the LTE supported data rates. Most importantly, reduced latencies experienced throughout the live tele-echography sessions allow the medical expert to remotely operate the robot in a responsive manner, using the wirelessly communicated cardiac ultrasound video to reach a diagnosis. Based on preliminary results documented in this Letter, the proposed robotised tele-echography platform can provide for reliable, remote diagnosis, achieving comparable quality of experience levels with in-hospital ultrasound examinations. PMID:27733929

  15. Advances in diagnostic ultrasonography.

    PubMed

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  16. Diagnostic imaging in ophthalmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, C.F.; Becker, M.H.; Flanagan, J.C.

    There are three sections in the book. The first section is a discussion of imaging techniques, which includes plain film radiography and multidirectional tomography of the orbit, computed tomography (CT) of the orbit and its use in the evaluation of ocular motility disorders, ultrasonography of the eye and orbit, investigation of the orbit by contrast techniques (which includes a brief review of angiography), the lachrimal drainage system, foreign body localization, and magnetic resonance imaging of the eye and orbit. There is extensive discussion of CT throughout the book. The second section is devoted to the role of these imaging methodsmore » in the evaluation of ophthalmic disorders. A discussion of congenital anomalies is useful for those centers that are exposed to unusual congenital anomalies and syndromes. Also included is evaluation of exophthalmous and thyroid ophthamalopathy, orbital tumors, lesions involving the visual pathways, CT assessment of paraorbital pathology (including basal and squamous cell tumors of the face), infection of the orbit, and orbital trauma. The third section is an overview of radiation therapy and malignant intraoccular tumors.« less

  17. Carpal Tunnel Syndrome: Symptoms, Causes and Treatment Options. Literature Reviev.

    PubMed

    Zamborsky, Radoslav; Kokavec, Milan; Simko, Lukas; Bohac, Martin

    2017-01-26

    Carpal Tunnel Syndrome (CTS) is the most common form of entrapment neuropathy. Several authors have investigated the anatomical and pathophysiological features of CTS and have identified several parameters that, in combination, play a significant role in its pathophysiology. Advancement in biological research on CTS has enabled the advent of efficient diagnostic techniques such as provocative tests and nerve conduction studies. Sophisticated technologies, such as magnetic resonance imaging (MRI) and ultrasonography (US), have facilitated the diagnosis of CTS. This review article aims at consolidating the relevant medical literature pertaining to the symptoms, pathophysiology, clinical diagnosis and treatment strategies of CTS. It also compares the various methods of diagnosis and discusses their benefits and disadvantages. Finally, it sheds light on the conservative vs. surgical approach to treatment and compares them. While the surgical approach has proved to be more efficient relative to the conservative methods of steroid injections and splinting, many studies have demonstrated both advantages and adverse effects of the surgical methods. Surgical options and complications are discussed in detail. This article comprehensively summarizes all medical aspects of CTS to update medical professionals' knowledge regarding the disease.

  18. Role of contrast-enhanced ultrasonography with Sonazoid for hepatocellular carcinoma: evidence from a 10-year experience.

    PubMed

    Maruyama, Hitoshi; Sekimoto, Tadashi; Yokosuka, Osamu

    2016-05-01

    Hepatocellular carcinoma (HCC) represents primary liver cancer. Because the development of HCC limits the prognosis as well as the quality of life of the patients, its management should be properly conducted based on an accurate diagnosis. The liver is the major target organ of ultrasound (US), which is the simple, non-invasive, and real-time imaging method available worldwide. Microbubble-based contrast agents are safe and reliable and have become popular, which has resulted in the improvement of diagnostic performances of US due to the increased detectability of the peripheral blood flow. Sonazoid (GE Healthcare, Waukesha, WI, USA), a second-generation contrast agent, shows the unique property of accumulation in the liver and spleen. Contrast-enhanced US with Sonazoid is now one of the most frequently used modalities in the practical management of liver tumors, including the detection and characterization of the nodule, evaluation of the effects of non-surgical treatment, intraoperative support, and post-treatment surveillance. This article reviews the 10-year evidence for contrast-enhanced US with Sonazoid in the practical management of HCC.

  19. Thoracic wall trauma—misdiagnosed lesions on radiographs and usefulness of ultrasound, multidetector computed tomography and magnetic resonance imaging

    PubMed Central

    Facenda, Catherine; Vaz, Nuno; Castañeda, Edgar Augusto; del Amo, Montserrat; Garcia-Diez, Ana Isabel; Pomes, Jaime

    2017-01-01

    Blunt injuries to the chest wall are an important chapter on emergency room (ER) departments, being the third most common injuries in trauma patients which ominous complications could appear. This article describes different types of traumatic events affecting the chest wall, which maybe misdiagnosed with conventional X-ray. Special emphasis has been done in computed tomography (CT) and multidetector CT (MDCT) imaging. This technique is considered the “gold-standard” for those traumatic patients, due to its fast acquisition covering the whole area of interest in axial plane, reconstructing multiplanar (2D, 3D) volume-rendered images with a superb quality and angiographic CT capabilities for evaluating vascular damage. Complementary techniques such as ultrasonography (US) and magnetic resonance imaging (MRI) may improve the diagnostic accuracy due to its great capacity in visualising soft-tissue trauma (muscle-tendinous tears) and subtle fractures. All these imaging methods have an important role in quantifying the severity of chest wall trauma. The findings of this study have been exposed with cases of our archives in a didactic way. PMID:28932697

  20. Physical examination and imaging of medial collateral ligament and posteromedial corner of the knee.

    PubMed

    Craft, Jason A; Kurzweil, Peter R

    2015-06-01

    The medial collateral ligament (MCL) is the most commonly injured knee ligament. Most will heal well with nonoperative treatment. However, not all medial knee injuries are the same. A detailed physical examination can help determine the severity of the medial-sided injury. When combined with advanced imaging, the examination will delineate damage to associated medial knee structures, including the location of MCL damage, posteromedial capsule injuries, and combined cruciate injuries. Failure to recognize MCL injuries that may be prone to chronic laxity can lead to significant disability, joint damage, and failure of concomitant cruciate ligament reconstructions. Magnetic resonance imaging is the mainstay of diagnostic imaging, with coronal sequences allowing full assessment of the MCL complex. Tangential views aid in the diagnosis of concomitant injuries. Stress radiography can play a role in evaluating MCL healing and subtle chronic laxity. Ultrasonography is also gaining acceptance as a means to assess MCL injuries. Use of a detailed examination and advanced imaging will allow optimal treatment of medial knee injuries and improve clinical outcomes.

  1. Penile involvement in Systemic Sclerosis: New Diagnostic and Therapeutic Aspects

    PubMed Central

    Aversa, Antonio; Bruzziches, Roberto; Francomano, Davide; Rosato, Edoardo; Salsano, Felice; Spera, Giovanni

    2010-01-01

    Systemic Sclerosis (SSc) is a connective tissue disorder featuring vascular alterations and an immunological activation leading to a progressive and widespread fibrosis of several organs such as the skin, lung, gastrointestinal tract, heart, and kidney. Men with SSc are at increased risk of developing erectile dysfunction (ED) because of the evolution of early microvascular tissutal damage into corporeal fibrosis. The entity of penile vascular damage in SSc patients has been demonstrated by using Duplex ultrasonography and functional infra-red imaging and it is now clear that this is a true clinical entity invariably occurring irrespective of age and disease duration and constituting the ‘‘sclerodermic penis”. Once-daily phosphodiesterase type-5 (PDE5) inhibitors improve both sexual function and vascular measures of cavernous arteries by improving surrogate markers of endothelial dysfunction, that is, plasma endothelin-1 and adrenomedullin levels, which may play a potential role in preventing progression of penile fibrosis and ED. Also, the beneficial effect of long-term PDE5i add-on therapy to SSc therapy in the treatment of Raynaud's phenomenon is described. PMID:20981315

  2. Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan.

    PubMed Central

    van Rossum, A. B.; Treurniet, F. E.; Kieft, G. J.; Smith, S. J.; Schepers-Bok, R.

    1996-01-01

    BACKGROUND: A study was carried out to evaluate the potential place of spiral volumetric computed tomography (SVCT) in the diagnostic strategy for pulmonary embolism. METHODS: In a prospective study 249 patients with clinical suspicion of pulmonary embolism were evaluated with various imaging techniques. In all patients a ventilation/perfusion (V/Q) scan was performed. Seventy seven patients with an abnormal V/Q scan underwent SVCT. Pulmonary angiography was then performed in all 42 patients with a non-diagnostic V/Q scan and in three patients with a high probability V/Q scan without emboli on the SVCT scan. Patients with an abnormal perfusion scan also underwent ultrasonography of the legs for the detection of deep vein thrombosis. RESULTS: One hundred and seventy two patients (69%) had a normal V/Q scan. Forty two patients (17%) had a non-diagnostic V/Q scan, and in five of these patients pulmonary emboli were found both by SVCT and pulmonary angiography. In one patient, although SVCT showed no emboli, the angiogram was positive for pulmonary embolism. In one of the 42 patients the SVCT scan showed an embolus which was not confirmed by pulmonary angiography. The other 35 patients showed no sign of emboli. Thirty five patients (14%) had a high probability V/Q scan, and in 32 patients emboli were seen on SVCT images. Two patients had both a negative SVCT scan and a negative pulmonary angiogram. In one who had an inconclusive SVCT scan pulmonary angiography was positive. The sensitivity for pulmonary embolism was 95% and the specificity 97%; the positive and negative predicted values of SVCT were 97% and 97%, respectively. CONCLUSIONS: SVCT is a relatively noninvasive test for pulmonary embolism which is both sensitive and specific and which may serve as an alternative to ventilation scintigraphy and possibly to pulmonary angiography in the diagnostic strategy for pulmonary embolism. Images PMID:8658363

  3. Specialized Diagnostic Investigations to Assess Ocular Status in Hypertensive Diseases of Pregnancy.

    PubMed

    Bakhda, Rahul Navinchandra

    2016-04-22

    This review describes specialized diagnostic investigations to assess ocular status in hypertensive diseases of pregnancy. Ocular assessment can aid in early detection for prompt multidisciplinary treatment, obstetric intervention and follow-up. The investigations accurately predict the possible causes of blindness in hypertensive diseases of pregnancy. The investigations include fluorescein angiography, ophthalmodynamometry, fluorophotometry, imaging modalities, OCT, ultrasonography, doppler velocimetry and blood chemistry analysis. The review includes a summary of imaging techniques and related recent developments to assess the neuro-ophthalmic aspects of the disease. The imaging modalities have been instrumental in understanding the complex neuropathophysiological mechanisms of eclamptic seizures. The importance of blood chemistry analysis in hypertensive diseases of pregnancy has been emphasized. The investigations have made a significant contribution in improving the standards of antenatal care and reducing maternal and fetal morbidity and mortality.

  4. Specialized Diagnostic Investigations to Assess Ocular Status in Hypertensive Diseases of Pregnancy

    PubMed Central

    Bakhda, Rahul Navinchandra

    2016-01-01

    This review describes specialized diagnostic investigations to assess ocular status in hypertensive diseases of pregnancy. Ocular assessment can aid in early detection for prompt multidisciplinary treatment, obstetric intervention and follow-up. The investigations accurately predict the possible causes of blindness in hypertensive diseases of pregnancy. The investigations include fluorescein angiography, ophthalmodynamometry, fluorophotometry, imaging modalities, OCT, ultrasonography, doppler velocimetry and blood chemistry analysis. The review includes a summary of imaging techniques and related recent developments to assess the neuro-ophthalmic aspects of the disease. The imaging modalities have been instrumental in understanding the complex neuropathophysiological mechanisms of eclamptic seizures. The importance of blood chemistry analysis in hypertensive diseases of pregnancy has been emphasized. The investigations have made a significant contribution in improving the standards of antenatal care and reducing maternal and fetal morbidity and mortality. PMID:28933399

  5. Recent advances of ultrasound imaging in dentistry--a review of the literature.

    PubMed

    Marotti, Juliana; Heger, Stefan; Tinschert, Joachim; Tortamano, Pedro; Chuembou, Fabrice; Radermacher, Klaus; Wolfart, Stefan

    2013-06-01

    Ultrasonography as an imaging modality in dentistry has been extensively explored in recent years due to several advantages that diagnostic ultrasound provides. It is a non-invasive, inexpensive, painless method and unlike X-ray, it does not cause harmful ionizing radiation. Ultrasound has a promising future as a diagnostic imaging tool in all specialties in dentistry, for both hard and soft tissue detection. The aim of this review is to provide the scientific community and clinicians with an overview of the most recent advances of ultrasound imaging in dentistry. The use of ultrasound is described and discussed in the fields of dental scanning, caries detection, dental fractures, soft tissue and periapical lesions, maxillofacial fractures, periodontal bony defects, gingival and muscle thickness, temporomandibular disorders, and implant dentistry. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Diagnostic accuracy of Onen's Alternative Grading System combined with Doppler evaluation of ureteral jets as an alternative in the diagnosis of obstructive hydronephrosis in children.

    PubMed

    de Bessa, Jose; Rodrigues, Cicilia M; Chammas, Maria Cristina; Miranda, Eduardo P; Gomes, Cristiano M; Moscardi, Paulo R; Bessa, Marcia C; Molina, Carlos A; Tiraboschi, Ricardo B; Netto, Jose M; Denes, Francisco T

    2018-01-01

    Ureteropelvic junction obstruction (UPJO) is a common congenital anomaly leading to varying degrees of hydronephrosis (HN), ranging from no apparent effect on the renal function to atrophy. Evaluation of these children is based on Diuretic Renal Scintigraphy (DRS) and Ultrasonography (US). Recent studies have suggested that new parameters of conventional and color Doppler ultrasonography (CDUS) may be useful in discriminating which kidneys are obstructed. The present study aims to assess the diagnostic accuracy of such parameters in the diagnosis of obstruction in children with UPJO. We evaluated 44 patients (33 boys) with a mean age of 6.53 ± 4.39 years diagnosed with unilateral high-grade hydronephrosis (SFU grades 3 and 4). All underwent DRS and index tests (conventional US and CDUS to evaluate ureteral jets frequency) within a maximum interval of two weeks. Hydronephrotic units were reclassified according to the alternative grading system (AGS) proposed by Onen et al. Obstruction in the DRS was defined as a differential renal function <40% on the affected side and/or features indicating poor drainage function like T1/2 >20 minutes after the administration of furosemide, and a plateau or ascending pattern of the excretion curve. Nineteen hydronephrotic units (43.1%) were obstructed. Some degree of cortical atrophy-grades 3 (segmental) or 4 (diffuse)-was present in those obstructed units. AGS grades had 100% sensitivity, 76% of specificity and 86.4% of accuracy. The absence of ureteral jets had a sensitivity of 73.68%, a specificity of 100% with an accuracy of 88.6%. When we analyzed the two aspects together and considered obstructed the renal units classified as AGS grade 3 or 4 with no jets, sensitivity increased to 78.9%, accuracy to 92%, remaining with a maximum specificity of 100%. These features combined would allow us to avoid performing DRS in 61% of our patients, leaving more invasive tests to inconclusive cases. Although DRS remains the mainstay to distinguishing obstructive from non-obstructive kidneys, grade of hydronephrosis and frequency of ureteral jets, independently or in combination may be a reliable alternative in the mostly cases.This alternative approach has high accuracy, it is less invasive, easily reproducible and may play a role in the diagnosis of obstruction in pediatric population.

  7. A comparison between gastroesophagheal ultrasonography vs. barium swallow in determining the pattern of gastroesophageal reflux in a pediatric population.

    PubMed

    Khatami, Alireza; Allameh, Mohammad Mahdi; Shahnazi, Makhtoom; Kiumarsi, Azadeh; Tajik, Ali

    2015-03-01

    Gastroesophageal reflux disease (GERD) is one of the most common gastrointestinal pathology in infants and young children. Ultrasonography (US) has been considered to be a reliable diagnostic tool for GERD but the severity of GERD and the clinical implications based on imaging findings has not been evaluated. To compare the diagnostic value of lower esophageal US with that of barium swallow in demonstrating the severity of GERD. Fifty one pediatric patients, age between 1 month to 12 years, 34 male and 17 female with clinical suspicion of GERD were included. The patients were initially submitted to barium swallow (BS) and subsequently to transabdominal US. During BS, the number of gastroesophageal reflux episodes was documented in a 5-minute period. Transabdominal US documented the number and duration of reflux episodes during a 5-minute period, the angle of His, mucosal thickness, and intraabdominal esophageal length (IAEL). Duration and number of reflux episodes in US were significantly higher in patients that had severe gastroesophageal refluxes at BS. At US the cutoff point of 9.5 seconds (sensitivity 80%, specificity 60%) for reflux duration and more than 2 episodes in 5 minute ultrasound study (sensitivity 75%, specificity 58%) were defined to correlate with severe gastroesophageal reflux at BS.The angle of His, the esophageal wall mucosal thickness, and the IAEL did not correlate with the severity of GERD detected in BS. US can predict the severity of GERD. Therefore, except in the case of specific patients in whom mechanical causes are suspected to be responsible for GERD, BS can be replaced by US.

  8. Radioimmunotargeting in ovarian carcinoma patients with indium-111 labeled monoclonal antibody OV-TL 3 F(ab')2: pharmacokinetics, tissue distribution, and tumor imaging.

    PubMed

    Buist, M.R.; Kenemans, P.; Vermorken, J.B.; Golding, R.P.; Burger, C.W.; Den Hollander, W.; Van Kamp, G.J.; Van Lingen, A.; Teule, G.J.J.; Baak, J.P.A.; Roos, J.C.

    1992-01-01

    Safety and feasibility of tumor targeting with radiolabeled monoclonal antibodies was studied in 28 patients suspected of having ovarian carcinoma, after i.v. administration of 1 mg F(ab')2 fragments of the murine monoclonal antibody OV-TL 3, labeled with 150 MBq Indium-111. There were no adverse reactions, hematological and biochemical serum parameters were stable. In one patient a (subclinical) HAMA-response was found. Plasma clearance of the immunoconjugate was biphasic with half lives of t(1/2)}alpha = 1.4+/-0.8 h and t(1/2)}beta = 25.1+/-3.7 h, resulting in an optimal time period for immunoscintigraphy at 24-48 h after administration. In 20 patients, undergoing extensive explorative surgery, a total of 271 samples of tumorous and normal tissues were analyzed for radiolabel uptake and tumor presence. The mean uptake in tumor deposits was 5.6 times (range 2.2-19.3) as high as the uptake in normal tissues (fat, peritoneum, muscle, skin). The diagnostic accuracy of immunosctigraphy was compared with that obtained with computer tomography, magnetic resonance imaging, ultrasonography and physical examination. While pelvic localizations were equally well detected by all methods, 48% of the abdominally located tumor deposits were correctly diagnosed by immunoscintigraphy, with only 12% detected by ultrasonography, 8% by CT-scanning and physical examination, and 6% by MRI. Immunoscintigraphy has potential as a diagnostic tool in ovarian cancer patients and biolocalization results justify further research into the therapeutic application of labeled monoclonal antibodies.

  9. Nationwide epidemiological survey of early chronic pancreatitis in Japan.

    PubMed

    Masamune, Atsushi; Kikuta, Kazuhiro; Nabeshima, Tatsuhide; Nakano, Eriko; Hirota, Morihisa; Kanno, Atsushi; Kume, Kiyoshi; Hamada, Shin; Ito, Tetsuhide; Fujita, Motokazu; Irisawa, Atsushi; Nakashima, Masanori; Hanada, Keiji; Eguchi, Takaaki; Kato, Ryusuke; Inatomi, Osamu; Shirane, Akio; Takeyama, Yoshifumi; Tsuji, Ichiro; Shimosegawa, Tooru

    2017-08-01

    The world's first diagnostic criteria for early CP were proposed in 2009 in Japan. This study aimed to clarify the clinico-epidemiological features of early CP in Japan. Patients with early CP who were diagnosed according to the diagnostic criteria for early CP and had visited the selected hospitals in 2011 were surveyed. The study consisted of two-stage surveys: the number of patients with early CP was estimated by the first questionnaire and their clinical features were assessed by the second questionnaire. The estimated number of early CP patients was 5410 (95% confidence interval 3675-6945), with an overall prevalence of 4.2 per 100,000 persons. The number of patients who were newly diagnosed with early CP was estimated to be 1330 (95% confidence interval 1058-1602), with an annual incidence of 1.0 per 100,000 persons. Detailed clinical information was obtained in 151 patients in the second survey. The male-to-female sex ratio was 1.32:1. The mean age was 60.4 and the mean age at disease onset was 55.4. Idiopathic (47.7%) and alcoholic (45.0%) were the two most common etiologies. Proportions of female and idiopathic cases were higher in early CP than in definite CP. Hyperechoic foci without shadowing and stranding were the most common findings on endoscopic ultrasonography. The clinical profiles of early CP patients who showed lobularity with honeycombing on endoscopic ultrasonography or previous episodes of acute pancreatitis were similar to those of definite CP patients. We clarified the current status of early CP in Japan.

  10. [Diagnostic performance of MR imaging, coloscan and MRI/CT enterography for the diagnosis of pelvic endometriosis: CNGOF-HAS Endometriosis Guidelines].

    PubMed

    Thomassin-Naggara, I; Bendifallah, S; Rousset, P; Bazot, M; Ballester, M; Darai, E

    2018-03-01

    Diagnostic performance of MR imaging for the diagnosis of pelvic endometriosis are good. Even if some differences of performances exists according the location considered, the risk of misdiagnosis is lower than 10% for trained teams (NP2). The performance of pelvic MR imaging and surgery are quite similar to diagnose endometrioma (sensitivity and specificity>90%). A negative pelvic MR imaging allows to exclude deep pelvic endometriosis with a performance similar to surgery but a positive MR imaging is less accurate than surgery because of a high number of false positives (23%). Pelvic MR imaging is more sensitive and less specific than ultrasonography for the diagnosis of uterosacral ligament, vagina or recto vaginal septum (NP2). Pelvic ultrasonography is more sensitive than pelvic MR imaging for the diagnosis of colorectal location (NP3). Pelvic MR imaging is a reproducible technique for the diagnosis of pelvic endometriosis (NP3). Regarding, quality criteria of pelvic MR imaging, no data are enough to recommend a specific MR unit, digestive preparation, or a specific moment during the menstrual cycle to realize the examination. Vaginal and/or rectal opacification are options. Most of studies are based a protocol including 3D T2W and 3DT1W sequences. Gadolinium injection is useful to characterize a complex adnexal mass. In clinical routine, slices crossing the kidneys are useful to evaluate the presence of pyelo calic distension. ColoCT is an accurate technique to diagnose pelvic digestive endometriosis (rectosigmoide and iléocaecal) (NP3). Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. Computer-aided diagnosis of focal liver lesions by use of physicians' subjective classification of echogenic patterns in baseline and contrast-enhanced ultrasonography.

    PubMed

    Sugimoto, Katsutoshi; Shiraishi, Junji; Moriyasu, Fuminori; Doi, Kunio

    2009-04-01

    To develop a computer-aided diagnostic (CAD) scheme for classifying focal liver lesions (FLLs) by use of physicians' subjective classification of echogenic patterns of FLLs on baseline and contrast-enhanced ultrasonography (US). A total of 137 hepatic lesions in 137 patients were evaluated with B-mode and NC100100 (Sonazoid)-enhanced pulse-inversion US; lesions included 74 hepatocellular carcinomas (HCCs) (23: well-differentiated, 36: moderately differentiated, 15: poorly differentiated HCCs), 33 liver metastases, and 30 liver hemangiomas. Three physicians evaluated single images at B-mode and arterial phases with a cine mode. Physicians were asked to classify each lesion into one of eight B-mode and one of eight enhancement patterns, but did not make a diagnosis. To classify five types of FLLs, we employed a decision tree model with four decision nodes and four artificial neural networks (ANNs). The results of the physicians' pattern classifications were used successively for four different ANNs in making decisions at each of the decision nodes in the decision tree model. The classification accuracies for the 137 FLLs were 84.8% for metastasis, 93.3% for hemangioma, and 98.6% for all HCCs. In addition, the classification accuracies for histological differentiation types of HCCs were 65.2% for well-differentiated HCC, 41.7% for moderately differentiated HCC, and 80.0% for poorly differentiated HCC. This CAD scheme has the potential to improve the diagnostic accuracy of liver lesions. However, the accuracy in the histologic differential diagnosis of HCC based on baseline and contrast-enhanced US is still limited.

  12. Diagnosis of Polycystic Ovary Syndrome: AMH in combination with clinical symptoms.

    PubMed

    Sahmay, Sezai; Aydin, Yavuz; Oncul, Mahmut; Senturk, Levent M

    2014-02-01

    We assessed the utility of using anti-Müllerian hormone (AMH) and clinical features of polycystic ovary syndrome (PCOS), polycystic ovarian morphology (PCOM), oligo/amenorrhea (OA), and hyperandrogenism (HA) for diagnosing PCOS, and compared their diagnostic accuracy with those of classical diagnostic systems. A total of 606 females were admitted to a university hospital with menstrual irregularities or symptoms of hyperandrogenism were enrolled in this cross-sectional study. Fasting blood samples were collected. Pelvic and/or abdominal ultrasonography and clinical examination were performed. Patients were evaluated for the presence of PCOS according to conventional diagnostic criteria. The diagnostic performance of using serum AMH levels alone and in various combinations with the clinical features of PCOM, OA, and HA were investigated. For the diagnosis of PCOS, the combination of OA and/or HA with AMH showed 83% sensitivity and 100% specificity according to the Rotterdam criteria; 83% sensitivity and 89% specificity according to the National Institutes of Health (NIH) criteria; and 82% sensitivity and 93.5% specificity according to the Androgen Excess Society (AES) criteria. The serum AMH level is a useful diagnostic marker for PCOS and is correlated with conventional diagnostic criteria. The combination of AMH level with OA and/or HA markedly increased the clinical scope for PCOS diagnosis and can be introduced as a possible objective criterion for the diagnosis of this disease.

  13. The diagnostic management of upper extremity deep vein thrombosis: A review of the literature.

    PubMed

    Kraaijpoel, Noémie; van Es, Nick; Porreca, Ettore; Büller, Harry R; Di Nisio, Marcello

    2017-08-01

    Upper extremity deep vein thrombosis (UEDVT) accounts for 4% to 10% of all cases of deep vein thrombosis. UEDVT may present with localized pain, erythema, and swelling of the arm, but may also be detected incidentally by diagnostic imaging tests performed for other reasons. Prompt and accurate diagnosis is crucial to prevent pulmonary embolism and long-term complications as the post-thrombotic syndrome of the arm. Unlike the diagnostic management of deep vein thrombosis (DVT) of the lower extremities, which is well established, the work-up of patients with clinically suspected UEDVT remains uncertain with limited evidence from studies of small size and poor methodological quality. Currently, only one prospective study evaluated the use of an algorithm, similar to the one used for DVT of the lower extremities, for the diagnostic workup of clinically suspected UEDVT. The algorithm combined clinical probability assessment, D-dimer testing and ultrasonography and appeared to safely and effectively exclude UEDVT. However, before recommending its use in routine clinical practice, external validation of this strategy and improvements of the efficiency are needed, especially in high-risk subgroups in whom the performance of the algorithm appeared to be suboptimal, such as hospitalized or cancer patients. In this review, we critically assess the accuracy and efficacy of current diagnostic tools and provide clinical guidance for the diagnostic management of clinically suspected UEDVT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Real-time elastography in the evaluation of diffuse thyroid disease: a study based on elastography histogram parameters.

    PubMed

    Yoon, Jung Hyun; Yoo, Jaeheung; Kim, Eun-Kyung; Moon, Hee Jung; Lee, Hye Sun; Seo, Jae Young; Park, Hye Young; Park, Woon-Ju; Kwak, Jin Young

    2014-09-01

    The purpose of this study was to evaluate the diagnostic performance of quantitative histogram parameters using real-time tissue elastography (RTE) in the diagnosis of patients with diffuse thyroid disease. One hundred and sixteen patients (mean age, 43.7 ± 10.97 y) who had undergone pre-operative staging ultrasonography and RTE were included. For each patient, 11 parameters were obtained from RTE images, from which the "elastic index" was calculated. Diagnostic performance of the elastic index and that of the 11 parameters on RTE were calculated and compared. Of the 116 patients, 31 had diffuse thyroid disease and 85 had normal thyroid parenchyma. Area under the receiver operating characteristic curve (A(z)) of MEAN (average relative value) elasticity was high (0.737), without significant differences from other elasticity values. Diagnostic performance of the elastic index was higher than the MEAN, A(z) = 0.753, without significance (p = 0.802). In conclusion, RTE using the elastic index was found to have good diagnostic performance and may be useful in the diagnosis and management of patients with diffuse thyroid disease. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Plantar fasciitis in athletes: diagnostic and treatment strategies. A systematic review

    PubMed Central

    Petraglia, Federica; Ramazzina, Ileana; Costantino, Cosimo

    2017-01-01

    Summary Background: Plantar fasciitis (PF) is reported in different sports mainly in running and soccer athletes. Purpose of this study is to conduct a systematic review of published literature concerning the diagnosis and treatment of PF in both recreational and élite athletes. The review was conducted and reported in accordance with the PRISMA statement. Methods: The following electronic databases were searched: PubMed, Cochrane Library and Scopus. As far as PF diagnosis, we investigated the electronic databases from January 2006 to June 2016, whereas in considering treatments all data in literature were investigated. Results: For both diagnosis and treatment, 17 studies matched inclusion criteria. The results have highlighted that the most frequently used diagnostic techniques were Ultrasonography and Magnetic Resonance Imaging. Conventional, complementary, and alternative treatment approaches were assessed. Conclusions: In reviewing literature, we were unable to find any specific diagnostic algorithm for PF in athletes, due to the fact that no different diagnostic strategies were used for athletes and non-athletes. As for treatment, a few literature data are available and it makes difficult to suggest practice guidelines. Specific studies are necessary to define the best treatment algorithm for both recreational and élite athletes. Level of evidence: Ib. PMID:28717618

  16. Screening for fetal growth restriction with universal third trimester ultrasonography in nulliparous women in the Pregnancy Outcome Prediction (POP) study: a prospective cohort study.

    PubMed

    Sovio, Ulla; White, Ian R; Dacey, Alison; Pasupathy, Dharmintra; Smith, Gordon C S

    2015-11-21

    Fetal growth restriction is a major determinant of adverse perinatal outcome. Screening procedures for fetal growth restriction need to identify small babies and then differentiate between those that are healthy and those that are pathologically small. We sought to determine the diagnostic effectiveness of universal ultrasonic fetal biometry in the third trimester as a screening test for small-for-gestational-age (SGA) infants, and whether the risk of morbidity associated with being small differed in the presence or absence of ultrasonic markers of fetal growth restriction. The Pregnancy Outcome Prediction (POP) study was a prospective cohort study of nulliparous women with a viable singleton pregnancy at the time of the dating ultrasound scan. Women participating had clinically indicated ultrasonography in the third trimester as per routine clinical care and these results were reported as usual (selective ultrasonography). Additionally, all participants had research ultrasonography, including fetal biometry at 28 and 36 weeks' gestational age. These results were not made available to participants or treating clinicians (universal ultrasonography). We regarded SGA as a birthweight of less than the 10th percentile for gestational age and screen positive for SGA an ultrasonographic estimated fetal weight of less than the 10th percentile for gestational age. Markers of fetal growth restriction included biometric ratios, utero-placental Doppler, and fetal growth velocity. We assessed outcomes for consenting participants who attended research scans and had a livebirth at the Rosie Hospital (Cambridge, UK) after the 28 weeks' research scan. Between Jan 14, 2008, and July 31, 2012, 4512 women provided written informed consent of whom 3977 (88%) were eligible for analysis. Sensitivity for detection of SGA infants was 20% (95% CI 15-24; 69 of 352 fetuses) for selective ultrasonography and 57% (51-62; 199 of 352 fetuses) for universal ultrasonography (relative sensitivity 2·9, 95% CI 2·4-3·5, p<0·0001). Of the 3977 fetuses, 562 (14·1%) were identified by universal ultrasonography with an estimated fetal weight of less than the 10th percentile and were at an increased risk of neonatal morbidity (relative risk [RR] 1·60, 95% CI 1·22-2·09, p=0·0012). However, estimated fetal weight of less than the 10th percentile was only associated with the risk of neonatal morbidity (pinteraction=0·005) if the fetal abdominal circumference growth velocity was in the lowest decile (RR 3·9, 95% CI 1·9-8·1, p=0·0001). 172 (4%) of 3977 pregnancies had both an estimated fetal weight of less than the 10th percentile and abdominal circumference growth velocity in the lowest decile, and had a relative risk of delivering an SGA infant with neonatal morbidity of 17·6 (9·2-34·0, p<0·0001). Screening of nulliparous women with universal third trimester fetal biometry roughly tripled detection of SGA infants. Combined analysis of fetal biometry and fetal growth velocity identified a subset of SGA fetuses that were at increased risk of neonatal morbidity. National Institute for Health Research, Medical Research Council, Sands, and GE Healthcare. Copyright © 2015 Sovio et al. Open Access article distributed under the terms of CC BY. Published by Elsevier Ltd.. All rights reserved.

  17. The Clinical Accuracy of Endoscopic Ultrasonography and White Light Imaging in Gastric Endoscopic Submucosal Dissection

    PubMed Central

    Park, Soon Hong; Sung, Sang Hun; Lee, Seung Jun; Jung, Min Kyu; Kim, Sung Kook

    2012-01-01

    Purpose Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection. PMID:22792522

  18. Fecal retention in childhood: Evaluation on ultrasonography.

    PubMed

    Hatori, Reiko; Tomomasa, Takeshi; Ishige, Takashi; Tatsuki, Maiko; Arakawa, Hirokazu

    2017-04-01

    To assess the usefulness of rectal diameter measurement on ultrasonography as a diagnostic tool for fecal retention in children. One hundred children (median age, 5.0 years), consisting of 80 with functional constipation and 20 without constipation, participated in the study. All patients underwent physical examination that included digital rectal examination. Forty-five children underwent ultrasonography in three differential planes: transection above the symphysis; under the ischial spine; and at the bladder neck. The measurement of the rectal diameter at the transection above the symphysis could most easily detect fecal retention and had the closest correlations with retention among the three planes. Rectal diameter was wider at all measuring points (35.2 vs 20.9 mm above the symphysis, P < 0.0001; 35.7 vs 24.0 mm under the ischial spine, P < 0.0001; and 19.4 vs 8.7 mm at the bladder neck, P < 0.0001) in children with fecal retention than in those with no fecal retention. With regard to presence of constipation, children with fecal retention had a wider rectal diameter above the symphysis than those with no fecal retention (children with functional constipation, 35.3 vs 20.0 mm, P < 0.0001; children without constipation: 32.6 vs 14.6 mm, P = 0.0026). The cut-off for the rectal diameter measured above the symphysis to identify fecal retention was 27 mm, with high sensitivity and specificity (95.5% and 94.1%, respectively). Ultrasound rectal diameter measurement can be used to detect fecal retention in children. © 2016 Japan Pediatric Society.

  19. Transthoracic lung ultrasound in normal dogs and dogs with cardiogenic pulmonary edema: a pilot study.

    PubMed

    Rademacher, Nathalie; Pariaut, Romain; Pate, Julie; Saelinger, Carley; Kearney, Michael T; Gaschen, Lorrie

    2014-01-01

    Pulmonary edema is the most common complication of left-sided heart failure in dogs and early detection is important for effective clinical management. In people, pulmonary edema is commonly diagnosed based on transthoracic ultrasonography and detection of B line artifacts (vertical, narrow-based, well-defined hyperechoic rays arising from the pleural surface). The purpose of this study was to determine whether B line artifacts could also be useful diagnostic predictors for cardiogenic pulmonary edema in dogs. Thirty-one normal dogs and nine dogs with cardiogenic pulmonary edema were prospectively recruited. For each dog, presence or absence of cardiogenic pulmonary edema was based on physical examination, heartworm testing, thoracic radiographs, and echocardiography. A single observer performed transthoracic ultrasonography in all dogs and recorded video clips and still images for each of four quadrants in each hemithorax. Distribution, sonographic characteristics, and number of B lines per thoracic quadrant were determined and compared between groups. B lines were detected in 31% of normal dogs (mean 0.9 ± 0.3 SD per dog) and 100% of dogs with cardiogenic pulmonary edema (mean 6.2 ± 3.8 SD per dog). Artifacts were more numerous and widely distributed in dogs with congestive heart failure (P < 0.0001). In severe cases, B lines increased in number and became confluent. The locations of B line artifacts appeared consistent with locations of edema on radiographs. Findings from the current study supported the use of thoracic ultrasonography and detection of B lines as techniques for diagnosing cardiogenic pulmonary edema in dogs. © 2014 American College of Veterinary Radiology.

  20. A clinical decision rule and D-dimer testing to rule out upper extremity deep vein thrombosis in high-risk patients.

    PubMed

    van Es, Nick; Bleker, Suzanne M; Di Nisio, Marcello; Kleinjan, Ankie; Beyer-Westendorf, Jan; Camporese, Giuseppe; Kamphuisen, Pieter W; Büller, Harry R; Bossuyt, Patrick M

    2016-12-01

    In a management study, a diagnostic algorithm consisting of a clinical decision rule, D-dimer, and ultrasonography was shown to safely exclude upper extremity deep vein thrombosis (UEDVT). Efficiency may be lower in high-risk subgroups: those with a central venous catheter or pacemaker, inpatients, cancer, and elderly patients. Data of 406 patients with suspected UEDVT enrolled in a prospective management study were used for the present analysis. The aim was to evaluate the efficiency of the algorithm in subgroups, defined as the proportion of patients in whom imaging could be safely withheld based on the combination of a decision rule result indicating "UEDVT unlikely" and a normal D-dimer result. The strategy excluded UEDVT in 87 of 406 patients (21%); ultrasonography was withheld in these patients and none developed UEDVT during 3months of follow-up. In contrast, ultrasonography could be withheld in only 4 of 92 patients with a catheter or pacemaker (4.3%; 95% CI: 1.7% to 11%) and in 4 of 83 inpatients (4.8%; 95% CI: 1.9% to 12%). The efficiency was 11% in patients with cancer and 13% in those older than 75years. Although the combination of a decision rule and D-dimer testing is safe in excluding UEDVT in the overall population of patients with suspected UEDVT, its efficiency appears limited in some subgroups, in particular those with a central venous catheter or pacemaker, and inpatients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Comparative Evaluation of Advanced and Conventional Diagnostic Aids for Endodontic Management of Periapical Lesions, An in Vivo Study

    PubMed Central

    Singh, Smita; Arora, Saurabh; Sandhu, Amneet Kaur; Dhingra, Ravneet

    2015-01-01

    Aim: To evaluate efficacy of Colour Doppler ultrasonography (CDUSG), direct digital radiography (DDR) and conventional radiography (CR) in diagnosis of periapical lesions and to clinically correlate treatment plan of periapical diseases. Materials and Methods: Thirty patients which were diagnosed with periapical lesions in anterior region by using both conventional and digital radiography were examined using colour doppler ultrasound imaging at the site of lesion. The images of each lesion were analysed by two endodontists and by an expert oral radiologist. A tentative differential diagnosis was agreed upon, based on certain principles discussed in article, then a diagnosis between cyst, granuloma and mixed lesions was made. Periapical lesions diagnosed as mixed lesions by colour doppler ultrasonography (CDUSG) were treated non-surgically whereas other periapical lesions were treated surgically. Tissues obtained during endodontic surgery were processed and examined for histopathological findings, and compared with the diagnosis made by ultrasound images. Statistical analysis was done with Chi-Square test and using one-way-Anova. Results: The periapical lesions which were diagnosed as granuloma by ultrasonographic findings, was confirmed by the results of histopathological examination in all 16 surgically treated cases. The lesions in rest of the 14 cases which showed vascularity and were diagnosed as mixed lesions by ultrasonography, were treated non-surgically and had a favourable prognosis. Conclusion: CR and DDR facilitate diagnosis of the presence of periapical disease, but do not provide and information of its nature. CDUSG imaging facilitates accurate information on the pathological nature of the lesion and hence can lead to predictable treatment planning. PMID:25738075

  2. Reproductive Medicine in Lizards.

    PubMed

    Knotek, Zdenek; Cermakova, Eva; Oliveri, Matteo

    2017-05-01

    Common reproductive problems in captive male lizards are hemipenile plugs in hemipenial sac, unilateral prolapse of hemipenis, or bilateral prolapse of hemipene. Although the orchiectomy is performed as a treatment for testicular disease, the effectiveness in reducing aggressive behavior is unclear. Female captive lizards suffer from cloacal prolapse, preovulatory follicular stasis, or dystocia. The veterinarian must differentiate between the disorders because the treatment differs. Mating, physical, or visual contact with the male stimulates ovulation and prevents preovulatory follicular stasis. Surgical intervention is usually required for dystocia. This article discusses selected procedures and use of ultrasonography and diagnostic endoscopy. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Stable Encapsulated Air Nanobubbles in Water.

    PubMed

    Wang, Yu; Liu, Guojun; Hu, Heng; Li, Terry Yantian; Johri, Amer M; Li, Xiaoyu; Wang, Jian

    2015-11-23

    The dispersion into water of nanocapsules bearing a highly hydrophobic fluorinated internal lining yielded encapsulated air nanobubbles. These bubbles, like their micrometer-sized counterparts (microbubbles), effectively reflected ultrasound. More importantly, the nanobubbles survived under ultrasonication 100-times longer than a commercial microbubble sample that is currently in clinical use. We justify this unprecedented stability theoretically. These nanobubbles, owing to their small size and potential ability to permeate the capillary networks of tissues, may expand the applications of microbubbles in diagnostic ultrasonography and find new applications in ultrasound-regulated drug delivery. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Myofibroblastoma of the male breast: a rare entity with radiologic-pathologic correlation

    PubMed Central

    Comer, John D.; Cui, Xiaoyan; Eisen, Carolyn Sharyn; Abbey, Genevieve; Arleo, Elizabeth Kagan

    2016-01-01

    A 73-year old man with a history of multiple genitourinary malignancies was found to have a left retroareolar soft tissue mass on CT assessment of disease, and dedicated breast imaging was recommended. Diagnostic mammography and ultrasonography confirmed a solid mass, for which biopsy was recommended. Pathologic analysis demonstrated a spindle cell neoplasm with an immunoreactivity pattern consistent with myofibroblastoma. While this entity is benign, nonspecific imaging features necessitate tissue sampling for pathologic diagnosis, and, given pathologic rarity, open communication between the radiologist and pathologist is important to establish the correct diagnosis and to recommend appropriate management. PMID:27936420

  5. Paediatric Gastrointestinal Endoscopy: European Society for Paediatric Gastroenterology Hepatology and Nutrition and European Society of Gastrointestinal Endoscopy Guidelines.

    PubMed

    Thomson, Mike; Tringali, Andrea; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf D; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro

    2017-01-01

    This guideline refers to infants, children, and adolescents ages 0 to 18 years. The areas covered include indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; corrosive ingestion and stricture/stenosis endoscopic management; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography; and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease has been dealt with in other guidelines and are therefore not mentioned in this guideline. Training and ongoing skill maintenance are to be dealt with in an imminent sister publication to this.

  6. Perspectives in ultrasound-guided musculoskeletal interventions

    PubMed Central

    Daftary, Aditya Ravindra; Karnik, Alpana Sudhir

    2015-01-01

    Ultrasonography (USG) is a safe, easily available, and cost-effective modality, which has the additional advantage of being real time for imaging and image-guided interventions of the musculoskeletal system. Musculoskeletal interventions are gaining popularity in sports and rehabilitation for rapid healing of muscle and tendon injuries in professional athletes, healing of chronic tendinopathies, aspiration of joint effusions, periarticular bursae and ganglia, and perineural injections in acute and chronic pain syndromes. This article aims to provide an overview of the spectrum of musculoskeletal interventions that can be done under USG guidance both for diagnostic and therapeutic purposes. PMID:26288519

  7. The history of imaging in obstetrics.

    PubMed

    Benson, Carol B; Doubilet, Peter M

    2014-11-01

    During the past century, imaging of the pregnant patient has been performed with radiography, scintigraphy, computed tomography, magnetic resonance imaging, and ultrasonography (US). US imaging has emerged as the primary imaging modality, because it provides real-time images at relatively low cost without the use of ionizing radiation. This review begins with a discussion of the history and current status of imaging modalities other than US for the pregnant patient. The discussion then turns to an in-depth description of how US technology advanced to become such a valuable diagnostic tool in the obstetric patient. Finally, the broad range of diagnostic uses of US in these patients is presented, including its uses for distinguishing an intrauterine pregnancy from a failed or ectopic pregnancy in the first trimester; assigning gestational age and assessing fetal weight; evaluating the fetus for anomalies and aneuploidy; examining the uterus, cervix, placenta, and amniotic fluid; and guiding obstetric interventional procedures.

  8. Recent advances in the imaging of hepatocellular carcinoma. From ultrasound to positron emission tomography scan.

    PubMed

    Camaggi, Valeria; Piscaglia, Fabio; Bolondi, Luigi

    2007-07-01

    Recent advances in imaging techniques for hepatocellular carcinoma (HCC) offer the possibility of investigating contrast perfusion of liver nodules in cirrhosis. It is now accepted that a non-invasive diagnosis of HCC can be established based on the vascular pattern obtained with pure blood pool contrast agents. The diagnostic pattern consists of contrast enhancement in the arterial phase, indicative of arterial hypervascularization, followed by contrast wash out in the portal and late phases, which leads the nodule to show the same, or, more specifically, a lower contrast signal than the surrounding parenchyma. Such patterns can be obtained by CT, MRI and, more recently, by real time Contrast Enhanced Ultrasonography with second-generation ultrasound contrast agents. A typical vascular pattern in a nodule perceptible also without contrast is highly specific for HCC, so that non-invasive diagnostic algorithms have been developed and recently updated.

  9. Diagnostic evaluation of ovarian torsion: An analysis of pediatric patients using the Nationwide Emergency Department Sample.

    PubMed

    Rialon, Kristy L; Wolf, Steven; Routh, Jonathan C; Adibe, Obinna O

    2017-04-01

    Ultrasonography (US) is the diagnostic modality of choice during work-up for ovarian torsion, although computed tomography (CT) may be used. We examined the utilization of CT in girls with ovarian torsion, and determined which patients are most likely to undergo this study. The Nationwide Emergency Department Sample dataset was searched for patients <18 years who presented with ovarian torsion from 2006 to 2012. Hospitals were categorized by the volume of pediatric patients seen. A total of 1279 patients were identified. Seven hundred twelve (56%) were seen at adult hospitals, 154 (12%) at pediatric privileged, and 413 (32%) at pediatric hospitals. Patients cared for in a pediatric or pediatric privileged hospital had more US alone performed to diagnose ovarian torsion (p < 0.01). Girls seen at pediatric hospitals are more likely to undergo US for work-up of ovarian torsion. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Pancreatic trauma: demographics, diagnosis, and management.

    PubMed

    Stawicki, Stanislaw Peter; Schwab, C William

    2008-12-01

    Pancreatic injuries are rare, with penetrating mechanisms being causative in majority of cases. They can create major diagnostic and therapeutic challenges and require multiple diagnostic modalities, including multislice high-definition computed tomography, magnetic resonance cholangiopancreatography, endoscopic retrograde cholangiopancreatography, ultrasonography, and at times, surgery and direct visualization of the pancreas. Pancreatic trauma is frequently associated with duodenal and other severe vascular and visceral injuries. Mortality is high and usually related to the concomitant vascular injury. Surgical management of pancreatic and pancreatic-duodenal trauma is challenging, and multiple surgical approaches and techniques have been described, up to and including pancreatic damage control and later resection and reconstruction. Wide surgical drainage is a key to any surgical trauma technique and access for enteral nutrition, or occasionally parenteral nutrition, are important adjuncts. Morbidity associated with pancreatic trauma is high and can be quite severe. Treatment of pancreatic trauma-related complications often requires a combination of interventional, endoscopic, and surgical approaches.

  11. Ultrasonography in Detection of Vaginal Foreign Bodies in Girls: A Retrospective Study.

    PubMed

    Yang, Xiuzhen; Sun, Liying; Ye, Jingjing; Li, Xiaoying; Tao, Ran

    2017-12-01

    In this study we investigated the sonographic features of vaginal foreign bodies in girls and the diagnostic role of combined transperineal and transabdominal ultrasonography in the detection of vaginal foreign bodies in this population. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: A retrospective review of the records of 249 girls seen in the outpatient pediatric and adolescent gynecology clinic of our hospital and referred to our department for sonographic evaluation of suspected vaginal foreign bodies between 2013 and 2016 was performed. All patients were transperineally and transabdominally scanned using an ultrasound machine with 3-MHz and 7.5-MHz transducers. The sonographic features of the detected foreign bodies were recorded and reported. All patients also underwent pelvic radiography. The presence of foreign bodies was confirmed using vaginoscopy. Two hundred forty-nine patients were included in this study, and vaginal foreign bodies were detected in 181 patients. Vaginal foreign bodies often present in girls aged from 2 to 12 years old. The most common vaginal foreign bodies were toilet paper, beads, small parts of toys, cap of water color brush, and crayons. The overall sensitivity, specificity, positive and negative predictive values of transperineal/transabdominal sonography in the diagnosis of vaginal foreign bodies were 81%, 53%, 82%, and 51%, respectively. The sensitivity, specificity, and positive and negative predictive values of transabdominal sonography were 33%, 49%, 63%, and 21%, respectively. The sensitivity, specificity, and positive and negative predictive values of transperineal sonography were 64%, 49%, 77%, and 33%, respectively. Abnormal findings were detected using x-ray in only 43 of the 181 cases (23.7%). The sensitivity, specificity, and positive and negative predictive values of x-ray were 24%, 91%, 88%, and 31%, respectively. The size of the foreign bodies ranged from 2 mm to 35 mm. For foreign bodies larger than 5 mm, the rate of sonographic accuracy reached 100%. For foreign bodies smaller than 5 mm, 32 false positive results, and 34 false negative results were identified. One hundred thirty-nine of 181 foreign bodies were less than 2 cm from the vaginal orifice (77%). All foreign bodies were hyperechoic compared with adjacent tissues. Some vaginal foreign bodies had characteristic echo patterns. With the exception of 1 patient with a detained AAA battery that caused vaginal ulceration, the other patients had a full recovery. Vaginal foreign bodies were hyperechoic compared with adjacent tissues and often had characteristic echo patterns. The use of combined transperineal and transabdominal ultrasonography might be helpful in diagnosing foreign bodies, especially when the size of the foreign body is larger than 5 mm. Therefore, ultrasonography might be preferred for the initial evaluation of suspected vaginal foreign bodies, because it is a noninvasive, radiation-free, and inexpensive technique. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  12. Diagnostic performance of alpha-fetoprotein, lens culinaris agglutinin-reactive alpha-fetoprotein, des-gamma carboxyprothrombin, and glypican-3 for the detection of hepatocellular carcinoma: a systematic review and meta-analysis protocol

    PubMed Central

    2013-01-01

    Background Diagnosis of early-stage hepatocellular carcinoma (HCC) followed by curative resection or liver transplantation offers the best chance for long-term patient survival. Clinically, ultrasonography has suboptimal sensitivity for detecting early-stage HCC. Several serological tests including alpha-fetoprotein (AFP), the ratio of lens culinaris agglutinin-reactive alpha-fetoprotein to total AFP (AFP-L3/AFP), des-gamma carboxyprothrombin (DCP), and glypican-3 (GPC-3) have been widely investigated as diagnostic biomarkers for early-stage HCC in at-risk populations. However, these tests are not recommended for routine HCC screening. Our objective is to determine the diagnostic performance of AFP, AFP-L3/AFP, DCP, and GPC-3 for the detection of HCC, particularly early-stage tumors meeting the Milan criteria. Methods/design We will include cross-sectional studies that consecutively or randomly recruit target populations. We will search the Cochrane Library, Medline, Embase, Science Citation Index, and the Chinese National Knowledge Infrastructure. We will also search the MEDION and ARIF databases to identify diagnostic systematic reviews that include primary studies. Reference lists of relevant reviews will be searched for additional trials. Language restrictions will not be applied. Two reviewers will independently screen study eligibility and extract data. Methodological quality will be assessed according to the revised tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Two authors will apply the QUADAS-2 assessment to all the included studies, and any discrepancies will be resolved by the third author. The following test characteristics will be extracted into 2 × 2 tables for all included studies: true positives, false positives, true negatives, and false negatives. Study-specific estimates of sensitivity and specificity with 95% confidence intervals will be displayed in forest plots. When possible, we will use the bivariate random-effects model or the Rutter and Gatsonis hierarchical summary receiver operating characteristic model for statistical analysis. To investigate heterogeneity, we will include study designs, population characteristics, test characteristics, and types of reference standard as the study-level variables. Discussion Our systematic review will allow patients, clinicians, and researchers to determine the diagnostic performance of AFP, AFP-L3/AFP, DCP, and GPC-3 for the detection of early-stage HCC and the potential roles of these diagnostic biomarkers in the existing diagnostic pathways. Systematic Review Registration: PROSPERO 2013; CRD42013003879 PMID:23738605

  13. Chest Ultrasonography in Modern Day Extreme Settings: From Military Setting and Natural Disasters to Space Flights and Extreme Sports

    PubMed Central

    Mucci, Viviana

    2018-01-01

    Chest ultrasonography (CU) is a noninvasive imaging technique able to provide an immediate diagnosis of the underlying aetiology of acute respiratory failure and traumatic chest injuries. Given the great technologies, it is now possible to perform accurate CU in remote and adverse environments including the combat field, extreme sport settings, and environmental disasters, as well as during space missions. Today, the usage of CU in the extreme emergency setting is more likely to occur, as this technique proved to be a fast diagnostic tool to assist resuscitation manoeuvres and interventional procedures in many cases. A scientific literature review is presented here. This was based on a systematic search of published literature, on the following online databases: PubMed and Scopus. The following words were used: “chest sonography,” “ thoracic ultrasound,” and “lung sonography,” in different combinations with “extreme sport,” “extreme environment,” “wilderness,” “catastrophe,” and “extreme conditions.” This manuscript reports the most relevant usages of CU in the extreme setting as well as technological improvements and current limitations. CU application in the extreme setting is further encouraged here. PMID:29736195

  14. Ultrasonographic assessment of the atlanto-occipital space in healthy Thoroughbred foals and Thoroughbred foals with neonatal maladjustment syndrome.

    PubMed

    Mackenzie, C J; Haggett, E F; Pinchbeck, G L; Marr, C M

    2017-05-01

    Ultrasonography of the atlanto-occipital (AO) space may be useful as a non-invasive diagnostic tool in neonatal foals. The aims of the study were establish a range of values for ultrasonographic measurements of the AO space in healthy Thoroughbred foals and to compare these variables in healthy foals with foals diagnosed with neonatal maladjustment syndrome (NMS). Ultrasonography of the AO space was performed on 38 healthy Thoroughbred foals and 28 Thoroughbred foals with NMS≤4days of age. Transverse image spinal cord height (P=0.001), width (P<0.001) and spinal cord cross sectional area (P<0.001), and longitudinal image dorsoventral diameter of the ventral spinal artery, were significantly smaller in foals with NMS than in healthy foals. Ratios of spinal canal to cord width and cross sectional area were significantly smaller in healthy foals than in foals with NMS (P<0.001). Spinal canal variables were not significantly different between groups. Several ultrasonographic measurements of the AO space were significantly different between healthy foals and foals with NMS. Further investigation is warranted to investigate the clinical application of this technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Ultrasonography of uterine leiomyomas.

    PubMed

    Woźniak, Andrzej; Woźniak, Sławomir

    2017-12-01

    Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan - TVS) or transabdominally (transabdominal scan - TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus.

  16. Non-contact photoacoustic tomography and ultrasonography for brain imaging

    NASA Astrophysics Data System (ADS)

    Rousseau, Guy; Blouin, Alain; Monchalin, Jean-Pierre

    2012-02-01

    Photoacoustic tomography (PAT) and ultrasonography (US) of biological tissues usually rely on transducer arrays for the detection of ultrasound. Obtaining the best sensitivity requires a physical contact with the tissue using an intermediate coupling fluid (water or gel). This type of contact is a major drawback for several applications such as neurosurgery. Laser-ultrasonics is an established optical technique for the non-contact generation and detection of ultrasound in industrial materials. In this paper, the non-contact detection scheme used in laser-ultrasonics is adapted to allow probing of ultrasound in biological tissues while remaining below laser exposure safety limits. Both non-contact PAT (NCPAT) and non-contact US (NCUS) are demonstrated experimentally using a single-frequency detection laser emitting suitably shaped pulses and a confocal Fabry-Perot interferometer. It is shown that an acceptable sensitivity is obtained while remaining below the maximum permissible exposure (MPE) of biological tissues. Results obtained ex vivo with a calf brain specimen show that sub-mm endogenous and exogenous inclusions can be detected at depths exceeding 1 cm. When fully developed, the technique could be a unique diagnostic tool in neurosurgery providing deep imaging of blood vessels, blood clots and blood oxygenation.

  17. Laser biostimulation therapy planning supported by imaging

    NASA Astrophysics Data System (ADS)

    Mester, Adam R.

    2018-04-01

    Ultrasonography and MR imaging can help to identify the area and depth of different lesions, like injury, overuse, inflammation, degenerative diseases. The appropriate power density, sufficient dose and direction of the laser treatment can be optimally estimated. If required minimum 5 mW photon density and required optimal energy dose: 2-4 Joule/cm2 wouldn't arrive into the depth of the target volume - additional techniques can help: slight compression of soft tissues can decrease the tissue thickness or multiple laser diodes can be used. In case of multiple diode clusters light scattering results deeper penetration. Another method to increase the penetration depth is a second pulsation (in kHz range) of laser light. (So called continuous wave laser itself has inherent THz pulsation by temporal coherence). Third solution of higher light intensity in the target volume is the multi-gate technique: from different angles the same joint can be reached based on imaging findings. Recent developments is ultrasonography: elastosonography and tissue harmonic imaging with contrast material offer optimal therapy planning. While MRI is too expensive modality for laser planning images can be optimally used if a diagnostic MRI already was done. Usual DICOM images offer "postprocessing" measurements in mm range.

  18. Diagnostic value of contrast-enhanced ultrasonography in the characterization of ovarian tumors☆

    PubMed Central

    Sconfienza, L.M.; Perrone, N.; Delnevo, A.; Lacelli, F.; Murolo, C.; Gandolfo, N.; Serafini, G.

    2009-01-01

    Introduction Vascularity influences the characteristics of gynecologic tumors observed with direct imaging techniques that reveal the macrovascular component of these lesions (color and power Doppler) and with indirect imaging involving the administration of contrast agents to examine the microcirculation and interstitial perfusion (contrast-enhanced computed tomography [CT] and magnetic resonance [MR] imaging). The purpose of this study was to determine whether contrast-enhanced ultrasonography (CEUS) of ovarian lesions provides useful information that cannot be obtained with conventional US. Materials and methods We used CEUS to assess 72 nonspecific adnexal lesions in 61 patients. CEUS was performed with a 4.8-ml bolus of a second-generation ultrasonographic contrast agent and dedicated imaging algorithms. For each lesion, B-mode morphology, CEUS morphology, and time/intensity curves were evaluated. Results In 8/61 cases (13.1%) CEUS offered no additional morphovascular information. In 38/61 cases (62.3%), it provided additional information that did not modify the management of the lesion, and in 15/61 cases (24.6%) it gave additional information that modified the management of the lesion. Malignant lesions were characterized by significantly shorter times to peak enhancement (11.9 ± 3.1 s vs 19.8 ± 4.0 s p < 0.01) and significantly higher peak intensity (24.7 ± 4.2 dB vs 17.8 ± 3.3 dB p < 0.01) compared with benign lesions. Conclusions CEUS improves diagnostic confidence in the characterization of liquid-corpuscular lesions where conventional US is inconclusive. CEUS can be proposed as a valid alternative to CT and MR. However, information obtained by CEUS influences the therapy in a limited percentage of cases (24.6%). PMID:23396092

  19. Imaging of intrahepatic progression of hepatocellular carcinoma post transarterial chemoembolization. A long-term, prospective evaluation of contrast-enhanced ultrasonography (CEUS).

    PubMed

    Moschouris, Hippocrates; Kalokairinou-Motogna, Mariana; Vrakas, Spyros; Papadatou, Aggeliki; Karagiannis, Eyaggelos; Kiltenis, Michail; Kladis-Kalentzis, Konstantinos; Marmaridou, Kyriaki; Papadogeorgopoulos, Nikolaos; Malagari, Katerina

    2017-04-22

    To assess the diagnostic efficacy of contrast-enhanced ultrasonography (CEUS) in the context of intrahepatic progression (IHP) of hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE). Sixty HCC patients were prospectively included in the study. They were treated with transarterial chemoembolization (TACE)with doxorubicin-eluting microspheres (231 sessions). Imaging follow-up was performed 1 month after each session and at 3-6 month intervals after the last session of TACE and included CEUS and contrast-enhanced magnetic resonance (MR) imaging (reference modality). The diagnosis of IHP was based on mRECIST criteria and the respective findings of MR and CEUS were recorded, categorized and correlated. A total of 441 CEUS studies were compared with the corresponding MR studies. During a follow-up period of 5-82 months (mean: 22 months), MR diagnosed 51 cases of IHP in 34/60 (56.6%) patients. CEUS correctly diagnosed 12/14 (85.7%) cases of IHP of target tumors, 2/5 (40%) cases of IHP of non-target tumors, 13/18 (72.2%) cases of distal and 6/9 (66.6%) cases of proximal new lesions, and 5/5 (100%) cases of major vessel involvement. On a per-lesion basis, CEUS was significantly inferior to MR in the detection of new lesions (p=0.002). No false positive CEUS diagnoses of IHP were observed. 54% of the diagnostic failures of CEUS were considered clinically significant.  In the long term evaluation of HCC post TACE, CEUS appears to have limitations in the detection of IHP, which are more prominent in the case of new lesions and of progressive non-target tumors.

  20. Diagnostic value of contrast-enhanced ultrasonography in the characterization of ovarian tumors().

    PubMed

    Sconfienza, L M; Perrone, N; Delnevo, A; Lacelli, F; Murolo, C; Gandolfo, N; Serafini, G

    2010-03-01

    Vascularity influences the characteristics of gynecologic tumors observed with direct imaging techniques that reveal the macrovascular component of these lesions (color and power Doppler) and with indirect imaging involving the administration of contrast agents to examine the microcirculation and interstitial perfusion (contrast-enhanced computed tomography [CT] and magnetic resonance [MR] imaging). The purpose of this study was to determine whether contrast-enhanced ultrasonography (CEUS) of ovarian lesions provides useful information that cannot be obtained with conventional US. We used CEUS to assess 72 nonspecific adnexal lesions in 61 patients. CEUS was performed with a 4.8-ml bolus of a second-generation ultrasonographic contrast agent and dedicated imaging algorithms. For each lesion, B-mode morphology, CEUS morphology, and time/intensity curves were evaluated. In 8/61 cases (13.1%) CEUS offered no additional morphovascular information. In 38/61 cases (62.3%), it provided additional information that did not modify the management of the lesion, and in 15/61 cases (24.6%) it gave additional information that modified the management of the lesion. Malignant lesions were characterized by significantly shorter times to peak enhancement (11.9 ± 3.1 s vs 19.8 ± 4.0 s p < 0.01) and significantly higher peak intensity (24.7 ± 4.2 dB vs 17.8 ± 3.3 dB p < 0.01) compared with benign lesions. CEUS improves diagnostic confidence in the characterization of liquid-corpuscular lesions where conventional US is inconclusive. CEUS can be proposed as a valid alternative to CT and MR. However, information obtained by CEUS influences the therapy in a limited percentage of cases (24.6%).

  1. Results of upper airway radiography and ultrasonography predict dynamic laryngeal collapse in affected horses.

    PubMed

    Fjordbakk, C T; Chalmers, H J; Holcombe, S J; Strand, E

    2013-11-01

    The pathogenesis of dynamic bilateral laryngeal collapse (DLC) associated with poll flexion is unknown. Diagnosis is dependent upon exercise endoscopy while replicating the flexed head position harness racehorses experience during racing. To describe the effects of poll flexion on rostrocaudal laryngeal positioning and laryngeal lumen width in resting horses diagnosed with DLC compared to controls, and to establish diagnostic criteria for DLC by use of diagnostic imaging. Case-control study. Fifty harness racehorses were prospectively included in the study: 25 cases diagnosed with DLC by treadmill endoscopy and 25 controls in which treadmill endoscopy revealed no abnormal findings. Laryngeal radiography and ultrasonography were obtained in neutral and flexed head positions. Laryngeal positioning and laryngohyoid conformation were compared between the groups and head positions. Poll flexion induced a greater rostral advancement of the larynx in relation to the hyoid apparatus in resting harness racehorses affected with DLC compared to controls (P = 0.007). At the level of the vocal folds, poll flexion resulted in a smaller laryngeal lumen width in horses affected with DLC compared to controls (P = 0.04). Horses were significantly more likely to be affected with DLC when the thyrohyoid bone to thyroid cartilage distance was ≥12 mm in poll flexion (odds ratio 21.3, 95% confidence interval 3.65-124.8, P = 0.004) and when laryngeal lumen width at the level of the vocal folds was less in poll flexion than in the neutral head position (odds ratio 8.4; 95% confidence interval 1.6-44.1, P = 0.012). In DLC horses, poll flexion advanced the larynx more rostrally and resulted in a decreased airway lumen width compared to control horses. Laryngeal ultrasound and radiography may facilitate the diagnosis of DLC at rest. © 2013 EVJ Ltd.

  2. Salivary calculus diagnosis with 3-dimensional cone-beam computed tomography.

    PubMed

    Dreiseidler, Timo; Ritter, Lutz; Rothamel, Daniel; Neugebauer, Jörg; Scheer, Martin; Mischkowski, Robert A

    2010-07-01

    The objective of this study was to evaluate cone-beam CT (CBCT) diagnoses of sialoliths in the major salivary glands. Twenty-nine CBCT images containing salivary calculi were retrospectively evaluated for image quality and artifact influence. Additionally, the reproducibility of calculus measurement and the differences between CBCT measurements and ultrasonography (US) and histomorphometry (HM) measurements were determined. Diagnostic sensitivity and specificity calculations were based on the observations of 3 masked clinicians, who reviewed a total of 58 CBCT volumes. Salivary calculi were sufficiently visualized in all patients. Metal artifacts were detected in images of 7 patients, and movement artifacts in 2. CBCT calculi measurements were highly reproducible, with mean differences of less than 350 microm. Mean CBCT measurements of calculi diameters differed from mean US measurements by approximately 500 microm and differed from mean HM measurements by approximately 1 mm. For calculus diagnoses, the mean sensitivity and specificity were both 98.85%. Although poor image qualities and artifacts can reduce diagnostic information, salivary calculi can be evaluated adequately with CBCT. CBCT measurements of calculi are highly reproducible and differ little from measurements made with US and HM. Diagnostic sensitivity and specificity levels with CBCT are as high as or higher than those obtained with other diagnostic methods. Because of its high diagnostic-information-to-radiation-dose ratio, CBCT is the preferable imaging modality for salivary calculus diagnosis. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  3. Diagnostic Criteria and Accuracy of Categorizing Malignant Thyroid Nodules by Ultrasonography and Ultrasound Elastography with Pathologic Correlation.

    PubMed

    Elsayed, Naglaa Mostafa; Elkhatib, Yasser Atta

    2016-03-01

    Thyroid nodules are a common medical and surgical concern. Thyroid ultrasound (US) is the primary imaging modality used for initial evaluation and assortment of nodules for fine needle aspiration (FNA) cytology/biopsy. Ultrasound elastography (USE) is believed to improve the diagnostic accuracy of US in distinguishing benign from malignant nodules. The aim of the work described here is to evaluate the diagnostic criteria and accuracy of US and USE in the diagnosis of malignant thyroid nodules. A prospective study of 88 patients who have thyroid nodules was performed. US, color Doppler, and USE were evaluated using a Philips iU22 equipped with a 5 to 12 MHz, linear transducer, followed by FNA of the each scanned nodule. The most sensitive US criteria for malignant nodules were a height-to-width ratio greater than one and the absence of a halo sign (sensitivity 0.875% and 1.000%, respectively). The most specific criteria for malignancy were a spiculated/blurred margin and the presence of microcalcifications (specificity 0.968% and 0.888%, respectively). The receiver operating characteristic curve showed that the cutoff diagnostic criteria of malignancy are two US characteristics and an elastography score of 4. The diagnostic accuracy of US for malignant thyroid nodules increases by combining US and USE. © The Author(s) 2015.

  4. Comparison of gray-scale contrast-enhanced ultrasonography with contrast-enhanced computed tomography in different grading of blunt hepatic and splenic trauma: an animal experiment.

    PubMed

    Tang, Jie; Li, Wenxiu; Lv, Faqin; Zhang, Huiqin; Zhang, Lihai; Wang, Yuexiang; Li, Junlai; Yang, Li

    2009-04-01

    To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with contrast-enhanced computed tomography (CECT) for the detection of different grading of solid organ injuries in blunt abdominal trauma in animals. A self-made miniature tools were used as models to simulate a blunt hepatic or splenic trauma in 16 and 14 anesthetized dogs, respectively. Baseline ultrasound, CEUS and CECT were used to detect traumatic injuries of livers and spleens. The degree of injuries was determined by CEUS according to the American Association for the Surgery of Trauma (AAST) scale and the results compared with injury scale based on CECT evaluation. CEUS showed 22 hepatic injury sites in 16 animals and 17 splenic injury sites in other 14 animals. According to AAST scale, 2 grade I, 4 grade II, 3 grade III, 5 grade IV and 2 grade V hepatic lesions were present in 16 animals; 2 grade I, 4 grade II, 6 grade III and 2 grade IV splenic lesions in 14 animals. On CECT scan, 21 hepatic and 17 splenic injuries were demonstrated. According to Becker CT scaling for hepatic injury, 1 grade I, 2 grade II, 4 grade III, 5 grade IV and 2 grade V hepatic injuries were present. On the basis of Buntain spleen scaling, 2 grade I, 5 grade II, 5 grade III, 2 grade IV splenic injuries were showed. After Spearman rank correlation analysis, the agreement of CEUS with CECT on the degree of hepatic and splenic injury is 93.3% and 92.9%, respectively. CT is currently considered as the reference method for grading blunt abdominal trauma, according to experiment results, CEUS grading showed high levels of concordance with CECT. CEUS can accurately determine the degree of injury and will play an important role in clinical application.

  5. COMPARISON OF THORACIC ULTRASONOGRAPHY AND RADIOGRAPHY FOR THE DETECTION OF INDUCED SMALL VOLUME PNEUMOTHORAX IN THE HORSE.

    PubMed

    Partlow, Jessica; David, Florent; Hunt, Luanne Michelle; Relave, Fabien; Blond, Laurent; Pinilla, Manuel; Lavoie, Jean-Pierre

    2017-05-01

    Small volume pneumothorax can be challenging to diagnose in horses. The current standard method for diagnosis is standing thoracic radiography. We hypothesized that thoracic ultrasonography would be more sensitive. Objectives of this prospective, experimental study were to describe a thoracic ultrasound method for detection of small volume pneumothorax in horses and to compare results of radiography and ultrasound in a sample of horses with induced small volume pneumothorax. Six mature healthy horses were recruited for this study. For each horse, five 50 ml air boluses were sequentially introduced via a teat cannula into the pleural space. Lateral thoracic radiographs and standardized ultrasound (2D and M-mode) examinations of both hemithoraces were performed following administration of each 50 ml air bolus. Radiographs and ultrasound images/videos were analyzed for detection of pneumothorax by four independent investigators who were unaware of treatment status. Sensitivity, specificity, positive predictive values, negative predictive values, and agreement among investigators (Kappa test, κ) were calculated for radiography, 2D and M-mode ultrasound. Comparisons were made using a chi-squared exact test with significance set at P < 0.05. Two-dimensional (84%) and M-mode (80%) ultrasound were more sensitive than radiography (48%) for pneumothorax detection (P = 0.02 and P = 0.04, respectively). Specificity and positive predictive values were similar for all three imaging modalities (P = 1). Agreement between investigators for pneumothorax detection was excellent for 2D ultrasound (κ = 1), very good for M-mode ultrasound (κ = 0.87), and good for radiography (κ = 0.79). Findings from this experimental study supported the use of thoracic ultrasonography as a diagnostic method for detecting pneumothorax in horses. © 2017 American College of Veterinary Radiology.

  6. Evidence and Recommendations for Imaging Liver Fat in Children, Based upon Systematic Review

    PubMed Central

    Awai, Hannah I.; Newton, Kimberly P.; Sirlin, Claude B.; Behling, Cynthia; Schwimmer, Jeffrey B.

    2013-01-01

    Background & Aims Fatty liver is a common problem in children, and increases their risk for cirrhosis, diabetes, and cardiovascular disease. Liver biopsy is the clinical standard for diagnosing and grading fatty liver. However, non-invasive imaging modalities are needed to assess liver fat in children. We performed a systematic review of studies that evaluated imaging of liver fat in children. Methods We searched PubMed for original research articles in peer-reviewed journals from January 1, 1982 through December 31, 2012 using the key words “imaging liver fat.” Studies included those in English, and those performed in children from birth to 18 y of age. To be eligible for inclusion, studies were required to measure hepatic steatosis via an imaging modality and a quantitative comparator as the reference standard. Results We analyzed 9 studies comprising 610 children; 4 studies assessed ultrasonography and 5 assessed magnetic resonance imaging (MRI). Ultrasonography was used in the diagnosis of fatty liver with positive predictive values of 47–62%. There was not a consistent relationship between ultrasound steatosis score and the reference measurement of hepatic steatosis. Liver fat as measurements by MRI or by spectroscopy varied with the methodologies used. Liver fat measurements by MRI correlated with results from histologic analyses, but sample size did not allow for assessment of diagnostic accuracy. Conclusions Available evidence does not support the use of ultrasonography for the diagnosis or grading of fatty liver in children. Although MRI is a promising approach, the data are insufficient to make evidence-based recommendations regarding its use in children for assessment of hepatic steatosis. PMID:24090729

  7. Clinical utility of magnetic resonance imaging and ultrasonography for diagnosis of polycystic ovary syndrome in adolescent girls.

    PubMed

    Kenigsberg, Lisa E; Agarwal, Chhavi; Sin, Sanghun; Shifteh, Keivan; Isasi, Carmen R; Crespi, Rebecca; Ivanova, Janeta; Coupey, Susan M; Heptulla, Rubina A; Arens, Raanan

    2015-11-01

    To evaluate ovarian morphology using three-dimensional magnetic resonance imaging (MRI) in adolescent girls with and without polycystic ovary syndrome (PCOS). Also compare the utility of MRI versus ultrasonography (US) for diagnosis of PCOS. Cross-sectional study. Urban academic tertiary-care children's hospital. Thirty-nine adolescent girls with untreated PCOS and 22 age/body mass index (BMI)-matched controls. Magnetic resonance imaging and/or transvaginal/transabdominal US. Ovarian volume (OV); follicle number per section (FNPS); correlation between OV on MRI and US; proportion of subjects with features of polycystic ovaries (PCOs) on MRI and US. Magnetic resonance imaging demonstrated larger OV and higher FNPS in subjects with PCOS compared with controls. Within the PCOS group, median OV was 11.9 (7.7) cm(3) by MRI compared with 8.8 (7.8) cm(3) by US. Correlation coefficient between OV by MRI and US was 0.701. Due to poor resolution, FNPS could not be determined by US or compared with MRI. The receiver operating characteristic curve analysis for MRI demonstrated that increasing volume cutoffs for PCOs from 10-14 cm(3) increased specificity from 77%-95%. For FNPS on MRI, specificity increased from 82%-98% by increasing cutoffs from ≥ 12 to ≥ 17. Using Rotterdam cutoffs, 91% of subjects with PCOS met PCO criteria on MRI, whereas only 52% met criteria by US. Ultrasonography measures smaller OV than MRI, cannot accurately detect follicle number, and is a poor imaging modality for characterizing PCOs in adolescents with suspected PCOS. For adolescents in whom diagnosis of PCOS remains uncertain after clinical and laboratory evaluation, MRI should be considered as a diagnostic imaging modality. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  8. Doppler ultrasonography combined with transient elastography improves the non-invasive assessment of fibrosis in patients with chronic liver diseases.

    PubMed

    Alempijevic, Tamara; Zec, Simon; Nikolic, Vladimir; Veljkovic, Aleksandar; Stojanovic, Zoran; Matovic, Vera; Milosavljevic, Tomica

    2017-01-31

    Accurate clinical assessment of liver fibrosis is essential and the aim of our study was to compare and combine hemodynamic Doppler ultrasonography, liver stiffness by transient elastography, and non-invasive serum biomarkers with the degree of fibrosis confirmed by liver biopsy, and thereby to determine the value of combining non-invasive method in the prediction significant liver fibrosis. We included 102 patients with chronic liver disease of various etiology. Each patient was evaluated using Doppler ultrasonography measurements of the velocity and flow pattern at portal trunk, hepatic and splenic artery, serum fibrosis biomarkers, and transient elastography. These parameters were then input into a multilayer perceptron artificial neural network with two hidden layers, and used to create models for predicting significant fibrosis. According to METAVIR score, clinically significant fibrosis (≥F2) was detected in 57.8% of patients. A model based only on Doppler parameters (hepatic artery diameter, hepatic artery systolic and diastolic velocity, splenic artery systolic velocity and splenic artery Resistance Index), predicted significant liver fibrosis with a sensitivity and specificity of75.0% and 60.0%. The addition of unrelated non-invasive tests improved the diagnostic accuracy of Doppler examination. The best model for prediction of significant fibrosis was obtained by combining Doppler parameters, non-invasive markers (APRI, ASPRI, and FIB-4) and transient elastography, with a sensitivity and specificity of 88.9% and 100%. Doppler parameters alone predict the presence of ≥F2 fibrosis with fair accuracy. Better prediction rates are achieved by combining Doppler variables with non-invasive markers and liver stiffness by transient elastography.

  9. Evidence and recommendations for imaging liver fat in children, based on systematic review.

    PubMed

    Awai, Hannah I; Newton, Kimberly P; Sirlin, Claude B; Behling, Cynthia; Schwimmer, Jeffrey B

    2014-05-01

    Fatty liver is a common problem in children and increases their risk for cirrhosis, diabetes, and cardiovascular disease. Liver biopsy is the clinical standard for diagnosing and grading fatty liver. However, noninvasive imaging modalities are needed to assess liver fat in children. We performed a systematic review of studies that evaluated imaging liver fat in children. We searched PubMed for original research articles in peer-reviewed journals from January 1, 1982, through December 31, 2012, using the key words "imaging liver fat." Studies included those in English, and those performed in children from birth to 18 years of age. To be eligible for inclusion, studies were required to measure hepatic steatosis via an imaging modality and a quantitative comparator as the reference standard. We analyzed 9 studies comprising 610 children; 4 studies assessed ultrasonography and 5 studies assessed magnetic resonance imaging (MRI). Ultrasonography was used in the diagnosis of fatty liver with positive predictive values of 47% to 62%. There was not a consistent relationship between ultrasound steatosis score and the reference measurement of hepatic steatosis. Liver fat as measurements by MRI or by spectroscopy varied with the methodologies used. Liver fat measurements by MRI correlated with results from histologic analyses, but sample size did not allow for an assessment of diagnostic accuracy. Available evidence does not support the use of ultrasonography for the diagnosis or grading of fatty liver in children. Although MRI is a promising approach, the data are insufficient to make evidence-based recommendations regarding its use in children for the assessment of hepatic steatosis. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. Comparison of thoracic auscultation, clinical score, and ultrasonography as indicators of bovine respiratory disease in preweaned dairy calves.

    PubMed

    Buczinski, S; Forté, G; Francoz, D; Bélanger, A-M

    2014-01-01

    The diagnostic tools for bovine respiratory disease diagnosis include clinical inspection, thoracic auscultation, and ultrasonography. Thoracic auscultation and clinical examination have limitations in the detection of lung consolidation in dairy calves. Prospective cohort of 106 preweaned calves from 13 different dairy herds (10 with a history of active bovine respiratory disease (BRD) in calves and 3 without suspected BRD problems). Each preweaned calf was clinically inspected using the Wisconsin calf respiratory scoring chart (CRSC) and treatment history was noted. Systematic thoracic auscultation and ultrasonography then were performed, the latter focusing on lung consolidation. Mortality was recorded over a 30-day period. A total of 56 of 106 calves had ultrasonographic evidence of lung consolidation. The sensitivity of thoracic auscultation to detect consolidation was 5.9% (range, 0-16.7%). Only 41.1% (23/33) of calves with consolidated lungs had been treated previously by the producers. When adding CRSC and previous BRD treatment by the producer, sensitivity of detection increased to 71.4% (40/56). The area under the receiver operating characteristics curve was 0.809 (95% CI, 0.721-0.879) for the number of areas within the lungs with consolidation and 0.743 (95% CI, 0.648-0.823) for the maximal depth of consolidation as predictors of death within 1 month after examination. These were not significantly different (P = .06). This study shows that thoracic auscultation is of limited value in diagnosing lung consolidation in calves. Ultrasonographic assessment of the thorax could be a useful tool to assess BRD detection efficiency on dairy farms. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  11. A study of bedside ocular ultrasonography in the emergency department.

    PubMed

    Blaivas, Michael; Theodoro, Daniel; Sierzenski, Paul R

    2002-08-01

    The use of ocular ultrasonography for the evaluation of emergency patients has recently been described in the emergency medicine (EM) literature. There are a number of potential uses that may greatly aid the emergency physician (EP) and avoid lengthy consultation or other diagnostic tests. To examine the accuracy of bedside ultrasonography as performed by EPs for the evaluation of ocular pathology. This prospective, observational study took place in a high-volume, suburban community hospital with an EM residency program. All patients arriving with a history of eye trauma or acute change in vision were eligible to participate in the study. A 10-MHz linear-array transducer was used for imaging. All imaging was performed through a closed eyelid, using water-soluble ultrasound gel. Investigators filled out standardized data sheets and all examinations were taped for review. All ultrasound examinations were followed by orbital computed tomography or complete ophthalmologic evaluation from the ophthalmology service. Statistical analysis included sensitivity, specificity, and positive and negative predictive values. Sixty-one patients were enrolled in the study; 26 were found to have intraocular pathology on ultrasound. Of these, three had penetrating globe injuries, nine had retinal detachments, one had central retinal artery occlusion, and two had lens dislocations. The remaining pathology included vitreous hemorrhage and vitreous detachment. Emergency sonologists were in agreement with the criterion standard examination in 60 out of 61 cases. Emergency bedside ultrasound is highly accurate for ruling out and diagnosing ocular pathology in patients presenting to the emergency department. Further, it accurately differentiates between pathology that needs immediate ophthalmologic consultation and that which can be followed up on an outpatient basis.

  12. Transabdominal ultrasonography of the ruminal mucosa as a tool to diagnose subacute ruminal acidosis in adult dairy bulls: a pilot study.

    PubMed

    Mirmazhari-Anwar, Vahid; Sharifi, Kamran; Mirshahi, Ali; Mohri, Mehrdad; Grünberg, Walter

    2013-01-01

    Subacute rumen acidosis (SARA) is frequently encountered in ruminants on high-concentrate rations and characterized by mild to moderate rumen pH depression. Although the measurement of rumen pH is considered as a gold standard approach to diagnose SARA, rumen fluid collection is conceived as a cumbersome and invasive procedure. In the present study, the suitability of transabdominal ultrasonography to identify structural changes of the rumen mucosa associated with SARA was explored. Five adult rumen canulated bulls previously adjusted to a roughage-based ration were switched in 10-day intervals to rations with increasing concentrate content. Seven rations with a concentrate content ranging from 5% to 95% were fed. The rumen pH and rumen mucosal thickness were measured at the end of each 10-d feeding period. The left flank was divided into 12 acoustic windows and the mean rumen mucosal thickness for each acoustic window determined for each ration. Repeated measure ANOVA and stepwise regression analyses were conducted. Increasing the dietary concentrate content resulted in thickening of rumen mucosa which was most pronounced in the upper part of the ventral rumen sac and the least pronounced in the uppermost and lowermost parts of the rumen. The intersection of a horizontal line going through the costochondral junction and a vertical line coming from the third lumbar vertebra was found to be most suitable to identify animals with rumen pH < 5.5 at 4 h post feeding. We conclude that transabdominal ultrasonography of the rumen mucosa has the potential to be a suitable, non-invasive diagnostic tool to identify adult ruminants with SARA.

  13. A cost-utility analysis of the use of preoperative computed tomographic angiography in abdomen-based perforator flap breast reconstruction.

    PubMed

    Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei

    2015-04-01

    Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.

  14. [Magnetic resonance imaging and ultrasonography in dogs and cats with ocular and orbital diseases. Part 1: Ocular diseases].

    PubMed

    von Krosigk, F; Steinmetz, A; Ellenberger, C; Oechtering, G

    2012-01-01

    This two-part study describes the clinical usefulness and value of ultrasound and magnetic resonance imaging (MRI) in dogs and cats with ocular (n=30) and orbital diseases (n=31). MRI and ultrasonography characteristics are described in single cases with ocular and orbital disease. Ultrasonography and MRI were performed in 15 dogs and 15 cats with intraocular neoplasia or intraocular inflammatory disease. In all patients with intraocular neoplasia, sonography revealed masses with increased echogenicity and fairly uniform echotexture, thus allowing the tentative diagnosis of an intraocular tumour. In these cases, MRI often proved to be a valuable diagnostic tool in showing the complete extent of intraocular lesion. An additional benefit of MRI was seen in the tissue characterization of tumours based on MRI signal characteristics and pattern of contrast enhancement. Discreet intraocular inflammatory alterations, in particular to the anterior and posterior segment of the eyeball, were more clearly shown by ultrasound than by MRI. Neoplasia could be excluded and inflammatory disease was successfully diagnosed using MRI due to the different image sequences with or without contrast medium administration. Traumatic ruptures of the lens capsule and the globe after trauma were depicted more clearly with MRI. When opacity of the anterior eye segment is present, various intraocular changes can be quickly diagnosed by ultrasound with high accuracy, without requiring anaesthesia of the patient. MRI of the globe allows differentiation of diverse pathologies, gives detailed information of infiltration in orbital structures and the exact degree of ocular lesions after trauma. This additional evidence often makes it easier to predict the correct prognosis and choose the best therapy.

  15. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    PubMed

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  16. [A Multimedia Tutorial to Train Ultrasonography of the Thyroid for Medical Students].

    PubMed

    Ritter, Julia; Wolfram, Maximilian; Schuler, Stefan; Guntinas-Lichius, Orlando

    2017-11-01

    Physicians in education often have poor experience in practice and assessment of ultrasonography on entering their profession, due to a deficiency of training offers during their study of medicine. Hence, a multimedia device for stepwise learning and training ultrasonography of the thyroid was developed. A software for a portable ultrasonography system was used to design a multimedia device for ultrasonography of the thyroid. It allows the user to illustrate texts and pictorial material simultaneously with ultrasound examination in order to compare own findings with examples from a database. The device was evaluated by 8 medical students and compared to a tutor-guided training. A structured, stepwise manual for ultrasonography of the thyroid with a large content of examples in different sectional images was designed for simultaneous reconstruction with the ultrasonography device. The informative content of the device and the replicability of the examination procedure were evaluated positively. Assessment respecting clarity, eligibility for users without experience and learning success was varying. The tutorial to learn and train ultrasonography of the thyroid is an instrument for self-learning and improving practical education in ultrasonography in medical education. In the next version, the manual for the examination will be structured in greater detail. © Georg Thieme Verlag KG Stuttgart · New York.

  17. [Etiology and diagnostic methods in vocal cord paralysis].

    PubMed

    Jørgensen, Gita; Clausen, Eva Wiinstedt; Mantoni, Margit Y; Misciattelli, Lorenzo; Balle, Viggo

    2003-02-10

    The etiology of vocal cord paralysis (VCP) is varied. There is lack of consensus regarding the choice of investigations to be used in the evaluation of VCP. The aim of this study was to establish the etiology, assess the diagnostic methods used in the evaluation, and outline an algorithm for future evaluation of unilateral vocal cord paralysis (UVCP). Charts of all patients (n = 94) with the diagnostic code of VCP were reviewed, and reexaminations were performed of patients in whom no etiology was found after the initial symptoms. The etiology of UVCP was neoplasm in 34%, surgical trauma in 12%, and miscellaneous causes in 54%. The etiology of bilateral vocal cord paralysis (BVCP) was neoplasm in 24%, surgical trauma in 24%, and miscellaneous causes in 52%. The reexaminations did not reveal any cancer diseases in the patients concerned. The most effective diagnostic method was CT-scanning while the least effective was thyroid scanning. Because cancer is a common cause of VCP a thorough evaluation is necessary. For UVCP we recommend history and physical examination, X-ray of the chest, ultrasonography of the neck, and CT-scanning of the superior mediastinum. If these prove negative, panendoscopy should be performed. Workup of patients with idiopathic VCP should include examination, X-ray of the chest at 6-month intervals, and annual CT-scanning for two years.

  18. Endoscopic Ultrasonography in the Diagnosis and Treatment Strategy Choice of Esophageal Leiomyoma.

    PubMed

    Sun, Ling-Jia; Chen, Xin; Dai, Yi-Ning; Xu, Cheng-Fu; Ji, Feng; Chen, Li-Hua; Chen, Hong-Tan; Chen, Chun-Xiao

    2017-04-01

    Esophageal leiomyoma is the most common benign tumor of the esophagus, and it originates from mesenchymal tissue. This study analyzed the clinicopathological characteristics of esophageal leiomyoma and aimed to evaluate the role of endoscopic ultrasonography in the diagnosis and treatment selection for these lesions. Two hundred and twenty-five patients who had suspected esophageal leiomyomas in endoscopic ultrasonography were enrolled at the Endoscopy Center of The First Affiliated Hospital, Zhejiang University from January 1st, 2009 to May 31th, 2015. The main outcomes included the demographic and morphological characteristics, symptoms, comparisons of diagnosis and treatment methods, adverse events, and prognosis. One hundred and sixty-seven patients were diagnosed as having an esophageal leiomyoma by pathological examination. The mean patient age was 50.57±9.983 years. In total, 62.9% of the lesions originated from the muscularis mucosa, and the others originated from the muscularis propria. The median distance to the incisors was 30±12 cm. The median diameter was 0.72±0.99 cm. As determined by endoscopic ultrasonography, most existing leiomyomas were homogeneous, endophytic, and spherical. The leiomyomas from the muscularis mucosa were smaller than those from the muscularis propria and much closer to the incisors (p<0.05). SMA (smooth muscle antibody) (97.2%) and desmin (94.5%) were positive in the majority of patients. In terms of treatments, patients preferred endoscopic therapies, which led to less adverse events (e.g., intraoperative bleeding, local infection, pleural effusion) than surgical operations (p<0.05). The superficial leiomyomas presented less adverse events and better recovery (p<0.05) than deep leiomyomas. Endoscopic ultrasonography has demonstrated high accuracy in the diagnosis of esophageal leiomyomas and provides great support in selecting treatments; however, EUS cannot completely avoid misdiagnosis, so combining it with other examinations may be a good strategy to solve this problem.

  19. Liver Contrast-Enhanced Ultrasound Improves Detection of Liver Metastases in Patients with Pancreatic or Periampullary Cancer.

    PubMed

    Taimr, Pavel; Jongerius, Vivian L; Pek, Chulja J; Krak, Nanda C; Hansen, Bettina E; Janssen, Harry L A; Metselaar, Herold J; van Eijck, Casper H J

    2015-12-01

    The aim of this study is to provide a diagnostic performance evaluation of contrast-enhanced ultrasonography (CEUS) in detecting liver metastases in patients with suspected of pancreatic or periampullary cancer. Computed tomography (CT) is often insufficient for detection of liver metastases, but their presence plays a crucial role in the choice of therapy. Eighty-nine patients with suspected pancreatic or periampullary cancer were included in this prospective study with retrospective analysis. Patients underwent an abdominal CT and CEUS. Fifteen patients had liver metastases. The CT sensitivity was 73.3% (11/15), the specificity 93.2% (69/74), the positive predictive value (PPV) 68.8% (11/16) and the negative predictive value (NPV) 94.6% (69/73). Based on CEUS, the sensitivity was 80% (12/15), specificity 98.6% (73/74), PPV 92.3% (12/13) and NPV 96.1% (73/76). CEUS improved characterization of liver lesions in patients with suspected pancreatic or periampullary cancer compared with CT. CEUS can better detect benign liver lesions and distinguish false-positive or indeterminate CT results. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Gastrointestinal endoscopy in pregnancy

    PubMed Central

    Savas, Nurten

    2014-01-01

    Gastrointestinal endoscopy has a major diagnostic and therapeutic role in most gastrointestinal disorders; however, limited information is available about clinical efficacy and safety in pregnant patients. The major risks of endoscopy during pregnancy include potential harm to the fetus because of hypoxia, premature labor, trauma and teratogenesis. In some cases, endoscopic procedures may be postponed until after delivery. When emergency or urgent indications are present, endoscopic procedures may be considered with some precautions. United States Food and Drug Administration category B drugs may be used in low doses. Endoscopic procedures during pregnancy may include upper gastrointestinal endoscopy, percutaneous endoscopic gastrostomy, sigmoidoscopy, colonoscopy, enteroscopy of the small bowel or video capsule endoscopy, endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography. All gastrointestinal endoscopic procedures in pregnant patients should be performed in hospitals by expert endoscopists and an obstetrician should be informed about all endoscopic procedures. The endoscopy and flexible sigmoidoscopy may be safe for the fetus and pregnant patient, and may be performed during pregnancy when strong indications are present. Colonoscopy for pregnant patients may be considered for strong indications during the second trimester. Although therapeutic endoscopic retrograde cholangiopancreatography may be considered during pregnancy, this procedure should be performed only for strong indications and attempts should be made to minimize radiation exposure. PMID:25386072

  1. A comparison of symptoms between non-ulcer dyspepsia patients positive and negative for Helicobacter pylori.

    PubMed

    Collins, J S; Knill-Jones, R P; Sloan, J M; Hamilton, P W; Watt, P C; Crean, G P; Love, A H

    1991-04-01

    The role of Helicobacter pylori infection in the symptom complex associated with non-ulcer dyspepsia is uncertain, despite the presence of the organism in a high proportion of these patients. In order to exclude physician bias in history taking, 18 patients (9 female) diagnosed as non-ulcer dyspepsia, after endoscopy and gallbladder ultrasonography, underwent computer interrogation using the Glasgow Diagnostic System for Dyspepsia (GLADYS). Five antral and 3 fundal endoscopic biopsies from these patients were also histologically examined for the presence of Helicobacter pylori and quantitatively analysed for polymorph and chronic inflammatory cell densities per mm2 of lamina propria using computer-linked image analysis. In the group of 9/18 patients who were positive for Helicobacter pylori, there were significantly higher antral and fundal inflammatory cell counts than in negative patients. However, analysis of the GLADYS interrogation data showed no significant positive relationships between Helicobacter pylori positivity and any gastrointestinal symptoms. These results confirm a significant association between Helicobacter pylori and superficial gastritis but suggest that non-ulcer dyspepsia in patients with Helicobacter pylori colonisation is probably not a clinically identifiable and distinct syndrome.

  2. Point-of-care ultrasonography by pediatric emergency medicine physicians.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Emergency physicians have used point-of-care ultrasonography since the 1990 s. Pediatric emergency medicine physicians have more recently adopted this technology. Point-of-care ultrasonography is used for various scenarios, particularly the evaluation of soft tissue infections or blunt abdominal trauma and procedural guidance. To date, there are no published statements from national organizations specifically for pediatric emergency physicians describing the incorporation of point-of-care ultrasonography into their practice. This document outlines how pediatric emergency departments may establish a formal point-of-care ultrasonography program. This task includes appointing leaders with expertise in point-of-care ultrasonography, effectively training and credentialing physicians in the department, and providing ongoing quality assurance reviews. Copyright © 2015 by the American Academy of Pediatrics.

  3. Gallbladder Boundary Segmentation from Ultrasound Images Using Active Contour Model

    NASA Astrophysics Data System (ADS)

    Ciecholewski, Marcin

    Extracting the shape of the gallbladder from an ultrasonography (US) image allows superfluous information which is immaterial in the diagnostic process to be eliminated. In this project an active contour model was used to extract the shape of the gallbladder, both for cases free of lesions, and for those showing specific disease units, namely: lithiasis, polyps and changes in the shape of the organ, such as folds or turns of the gallbladder. The approximate shape of the gallbladder was found by applying the motion equation model. The tests conducted have shown that for the 220 US images of the gallbladder, the area error rate (AER) amounted to 18.15%.

  4. Mycobacteriosis in a domestic ferret (Mustela putorius furo).

    PubMed

    Nakata, Makoto; Miwa, Yasutsugu; Tsuboi, Masaya; Uchida, Kazuyuki

    2014-05-01

    A 4-year-old spayed female ferret presented with a 2-month history of anorexia, vomiting and occasional diarrhea. Abdominal ultrasonography revealed thickening of the gastric wall and enlarged abdominal lymph nodes. Biopsy samples from the thickened gastric wall, enlarged abdominal lymph nodes and liver were taken during an exploratory laparotomy. Based on the histopathological examination, mycobacterium infection was diagnosed. The bacterial species could not be identified by additional diagnostic tests of feces, including fecal smear, culture and polymerase chain reaction (PCR). The ferret was treated with prednisolone and multiple antimicrobials, including rifampicin, azithromycin and enrofloxacin, but did not improve with treatment and died 220 days after the first presentation.

  5. Application of special diagnostic techniques in the management of nodular goitre.

    PubMed Central

    Walfish, P. G.; Miskin, M.; Rosen, I. B.; Strawbridge, H. T.

    1976-01-01

    The primary challenge in the management of nodular goitre is to establish which thyroid nodules are malignant. Since selection of patients for operation on the basis of palpation of nodules alone gives a low yield of malignant disease, physicians have sought criteria for selection that combine the information obtained from special laboratory procedures with thoughtful clinical appraisal. Such special procedures, which include radioisotope scintiscanning, echography by B-mode ultrasonography, and either large- or fine-needle aspiration and cytologic examination of the aspirate, are considered valuable in a proposed clinical approach to the management of thyroid nodules. Images FIG. 1 FIG. 2 FIG. 3 PMID:1277058

  6. Real-time Three-dimensional Echocardiography: From Diagnosis to Intervention.

    PubMed

    Orvalho, João S

    2017-09-01

    Echocardiography is one of the most important diagnostic tools in veterinary cardiology, and one of the greatest recent developments is real-time three-dimensional imaging. Real-time three-dimensional echocardiography is a new ultrasonography modality that provides comprehensive views of the cardiac valves and congenital heart defects. The main advantages of this technique, particularly real-time three-dimensional transesophageal echocardiography, are the ability to visualize the catheters, and balloons or other devices, and the ability to image the structure that is undergoing intervention with unprecedented quality. This technique may become one of the main choices for the guidance of interventional cardiology procedures. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Retrobulbar tumors in dogs and cats: 25 cases.

    PubMed

    Attali-Soussay, K; Jegou, J P; Clerc, B

    2001-03-01

    Twenty-five cases of retrobulbar tumors are presented and discussed. Affected animals were dogs and cats (average 10.7 years). No breed or sex predisposition was noted. The most common clinical signs were exophthalmos (84%), conjunctival hyperemia (40%), protrusion of the nictitating membrane (28%), exposure keratitis (20%) and fundus abnormalities (20%). Diagnostic tools included fine needle aspiration, radiography, ultrasonography, computed tomography and histology. Surgical treatment by orbitotomy or exenteration was combined with chemotherapy and radiotherapy in some cases. The prognosis was poor with low survival times: 1 month in cats, and 10 months in dogs, with a high rate of euthanasia (35%) at the time of diagnosis.

  8. Optimal Measurement Level and Ulnar Nerve Cross-Sectional Area Cutoff Threshold for Identifying Ulnar Neuropathy at the Elbow by MRI and Ultrasonography.

    PubMed

    Terayama, Yasushi; Uchiyama, Shigeharu; Ueda, Kazuhiko; Iwakura, Nahoko; Ikegami, Shota; Kato, Yoshiharu; Kato, Hiroyuki

    2018-06-01

    Imaging criteria for diagnosing compressive ulnar neuropathy at the elbow (UNE) have recently been established as the maximum ulnar nerve cross-sectional area (UNCSA) upon magnetic resonance imaging (MRI) and/or ultrasonography (US). However, the levels of maximum UNCSA and diagnostic cutoff values have not yet been established. We therefore analyzed UNCSA by MRI and US in patients with UNE and in controls. We measured UNCSA at 7 levels in 30 patients with UNE and 28 controls by MRI and at 15 levels in 12 patients with UNE and 24 controls by US. We compared UNCSA as determined by MRI or US and determined optimal diagnostic cutoff values based on receiver operating characteristic curve analysis. The UNCSA was significantly larger in the UNE group than in controls at 3, 2, 1, and 0 cm proximal and 1, 2, and 3 cm distal to the medial epicondyle for both modalities. The UNCSA was maximal at 1 cm proximal to the medial epicondyle for MRI (16.1 ± 3.5 mm 2 ) as well as for US (17 ± 7 mm 2 ). A cutoff value of 11.0 mm 2 for MRI and US was found to be optimal for differentiating between patients with UNE and controls, with an area under the receiver operating characteristic curve of 0.95 for MRI and 0.96 for US. The UNCSA measured by MRI was not significantly different from that by US. Intra-rater and interrater reliabilities for UNCSA were all greater than 0.77. The UNCSA in the severe nerve dysfunction group of 18 patients was significantly larger than that in the mild nerve dysfunction group of 12 patients. By measuring UNCSA with MRI or US at 1 cm proximal to the ME, patients with and without UNE could be discriminated at a cutoff threshold of 11.0 mm 2 with high sensitivity, specificity, and reliability. Diagnostic III. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Serum total prostate-specific antigen values in men with symptomatic prostate enlargement in Nigeria: role in clinical decision-making.

    PubMed

    Nnabugwu, Ikenna I; Ugwumba, Fred O; Enivwenae, Oghenekaro A; Udeh, Emeka I; Otene, Chris O; Nnabugwu, Chinwe A

    2015-01-01

    Prostatic enlargement is a common cause of bladder outlet obstruction in men in Nigeria. Malignant enlargements must be differentiated from benign enlargements for adequate treatment of each patient. High serum total prostate-specific antigen (tPSA) levels suggest malignancy, but some of the biopsies done due to a serum tPSA value >4 ng/mL would be negative for malignancy because of the low specificity of tPSA for prostate cancer. This study aims to compare the histologic findings of all prostate specimens obtained from core needle biopsy, open simple prostatectomy, and transurethral resection of the prostate with the respective serum tPSA values in an attempt to decipher the role of serum tPSA in the management of these patients. The case notes of patients attended to from April 2009 to March 2012 were analyzed. Essentially, the age of the patient, findings on digital rectal examination, abdominopelvic ultrasonography report on the prostate, serum tPSA, and histology reports from biopsy or prostatectomy specimens as indicated were extracted for analysis. The relationship between age, findings on digital rectal examination, serum tPSA, abdominopelvic ultrasonography report, and histology are compared. A statistically significant relationship existed between a malignant histology and age 65 years and older, suspicious findings on digital rectal examination, suspicious ultrasonography findings, and serum tPSA >10 ng/mL, but not tPSA >4 ng/mL. In Nigerian patients with symptomatic prostate enlargement, serum tPSA should be seen as a continuum with increasing risk of prostate malignancy.

  10. Clinical utility of colour flow Doppler ultrasonography in planning anterolateral thigh flap harvest.

    PubMed

    Patel, Rajan S; Higgins, Kevin M; Enepekides, Danny J; Hamilton, Paul A

    2010-10-01

    The anatomic variability of cutaneous perforators contributes to the technical challenges of anterolateral thigh (ALT) free flap harvest. The objective of this study was to assess the accuracy and clinical utility of preoperative colour flow Doppler (CFD) ultrasonography in evaluating planned ALT flap donor sites. A prospective study of the infrainguinal vasculature (profunda femoris and lateral circumflex femoral arteries) in 16 consecutive patients scheduled for ALT free flap transfer for reconstruction of head and neck surgical defects was undertaken. All patients underwent CFD ultrasonography. The location of perforators and the thigh thickness determined by CFD ultrasonography were correlated with the actual intraoperative findings using a scatter plot and paired t-test. Two patients were diagnosed with bilateral silent infrainguinal claudication, which precluded safe use of the ALT donor site. In two other patients, the planned ALT donor site ipsilateral to the defect was not used because of silent infrainguinal claudication diagnosed by CFD ultrasonography. In the 14 patients who underwent ALT flap harvest, CFD ultrasonography identified 48 perforators, which coincided with 43 actual perforators found intraoperatively. CFD ultrasonography demonstrated a statistically significant correlation with the actual perforator locations (Spearman coefficient .76; p = .55). Although CFD ultrasonography tended to underestimate flap thickness, there was a statistically significant correlation (Spearman coefficient .94; p ≤ .0001) with the actual flap thickness. CFD ultrasonography has clinical utility in facilitating decision making and planning ALT flap harvest.

  11. Increased survival of children with solid tumours: how did we get there and how to keep the success going?

    PubMed

    Rechnitzer, Catherine

    2011-10-03

    Survival after childhood cancer has dramatically increased in the last 3 to 4 decades. Among extracranial tumours, Wilms tumours and other less common kidney tumours have the best results, but treatment of neuroblastoma, often disseminated at diagnosis, is still extremely challenging. How did survival of solid tumours in childhood increase from around 30% in the 1970s to 70-90% today? This is the result of a multidisciplinary effort and access to improved diagnostic techniques and treatment modalities. This article focuses on the role of imaging in this positive evolution and particularly, how imaging will contribute to keep the survival curves improving. Radiologists and other imaging experts retain a key position before diagnosis and during and after treatment. Investigations before diagnosis are key to further investigations and referral with no delay. The first investigations will most often involve radiologists through radiography or ultrasonography, according to tumour site. The description of these first observations and particularly the conclusion and its wording are crucial to the subsequent events leading to diagnosis. In imaging at diagnosis, the aim is to obtain a precise description of the primary tumour and its local spread as soon as possible. The choice of technique depends on local conditions but may include ultrasonography, computed tomography (CT)/magnetic resonance imaging (MRI) scanning, scintigraphies (bone, meta-iodobenzylguanidine (MIBG), octreotide), or fluorodeoxyglucose (FDG)-positron emission tomography (PET), combined with low dose CT or MRI scanning. CT scan and chest radiography are recommended for investigating the presence of lung metastases. There is no infiltrate too small to be a metastasis. Overall there is no specific imaging criterion. The pathologists hold this diagnostic key. Tumour response is evaluated during and after preoperative chemotherapy using techniques and measurements comparable with those used at diagnosis. Following evaluation of tumour response, additional investigations may be needed to define the resectability of the tumour, combining different imaging techniques, e.g. CT scanning and/or MRI angiographies, ultrasound with Doppler. After tumour resection and particularly in the case of non-radical resection, imaging of the tumour residue is required as baseline for further surveillance and eventually planning of irradiation fields. How do we secure further improvement in treatment results for childhood cancer? Multidisciplinary teams, optimal logistics and continuous education are the best tools with focus on reduction in delay to diagnosis and improvement in the multidisciplinary forum allowing optimal therapeutic decisions.

  12. Effect of Ultrasonography on Student Learning of Shoulder Anatomy and Landmarks.

    PubMed

    de Vries, Kristen D; Brown, Rebecca; Mazzie, Joseph; Jung, Min-Kyung; Yao, Sheldon C; Terzella, Michael J

    2018-01-01

    Ultrasonography is becoming more common in clinical use, and it has been shown to have promising results when introduced into medical school curricula. To determine whether the use of ultrasonography as an educational supplement can improve osteopathic medical students' confidence and ability to locate 4 specific shoulder anatomical landmarks: the coracoid process, the transverse process of T1, the long head of the biceps within the bicipital groove, and the supraspinatus tendon. In this randomized controlled study, first-year osteopathic medical students aged 18 years or older were recruited and randomly assigned to a group with exposure (ultrasonography group) or without exposure (control group) to an ultrasonography machine. First, a survey was administered to measure students' baseline knowledge of shoulder anatomy, confidence in palpation skills, and opinion on anatomical landmark identification teaching methods. Next, students were shown presentations on shoulder anatomy and allowed to practice locating and palpating the specified landmarks. Students in the ultrasonography group were also given instruction on the use of ultrasonography. All students were asked to locate each of the 4 specified anatomical landmarks and then given a follow-up survey. A Mann Whitney U test was used to compare the confidence of the students before and after the intervention. A secondary analysis was performed to compare the degree of deviance from the correct position of the specified anatomical landmark between the ultrasonography and control groups. P values less than .05 were considered statistically significant. Sixty-four students participated. Compared with the control group, students in the ultrasonography group had a greater increase in confidence after the session in their ability to locate the coracoid process, bicipital tendon, and supraspinatus tendon (P=.022, P=.029, P=.44, respectively). Students in the ultrasonography group were also able to more accurately palpate the landmarks than those in the control group, with a significant difference in accurate palpation of the bicipital tendon (P=.024). The ultrasonography group showed less deviation with palpation of the other 3 landmarks compared with the control group, but these results were not significant (P=.50, P=.82, P=.29, respectively). Ultrasonography in the preclinical curriculum may improve medical students' confidence in and accuracy of palpation.

  13. Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.

    PubMed

    Stengel, Dirk; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas; Mutze, Sven

    2015-09-14

    Ultrasonography (performed by means of a four-quadrant, focused assessment of sonography for trauma (FAST)) is regarded as a key instrument for the initial assessment of patients with suspected blunt abdominal and thoraco-abdominal trauma in the emergency department setting. FAST has a high specificity but low sensitivity in detecting and excluding visceral injuries. Proponents of FAST argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of unnecessary multi-detector computed tomography (MDCT) scans, and enable quicker triage to surgical and non-surgical care. Given the proven accuracy, increasing availability of, and indication for, MDCT among patients with blunt abdominal and multiple injuries, we aimed to compile the best available evidence of the use of FAST-based assessment compared with other primary trauma assessment protocols. To assess the effects of diagnostic algorithms using ultrasonography including in FAST examinations in the emergency department in relation to the early, late, and overall mortality of patients with suspected blunt abdominal trauma. The most recent search was run on 30th June 2015. We searched the Cochrane Injuries Group Specialised Register, The Cochrane Library, MEDLINE (OvidSP), EMBASE (OvidSP), ISI Web of Science (SCI-EXPANDED, SSCI, CPCI-S, and CPSI-SSH), clinical trials registers, and screened reference lists. Trial authors were contacted for further information and individual patient data. We included randomised controlled trials (RCTs). Participants were patients with blunt torso, abdominal, or multiple trauma undergoing diagnostic investigations for abdominal organ injury. The intervention was diagnostic algorithms comprising emergency ultrasonography (US). The control was diagnostic algorithms without US examinations (for example, primary computed tomography (CT) or diagnostic peritoneal lavage (DPL)). Outcomes were mortality, use of CT or invasive procedures (DPL, laparoscopy, laparotomy), and cost-effectiveness. Two authors (DS and CG) independently selected trials for inclusion, assessed methodological quality, and extracted data. Methodological quality was assessed using the Cochrane Collaboration risk of bias tool. Where possible, data were pooled and relative risks (RRs), risk differences (RDs), and weighted mean differences, each with 95% confidence intervals (CIs), were calculated by fixed-effect or random-effects models as appropriate. We identified four studies meeting our inclusion criteria. Overall, trials were of poor to moderate methodological quality. Few trial authors responded to our written inquiries seeking to resolve controversial issues and to obtain individual patient data. Strong heterogeneity amongst the trials prompted discussion between the review authors as to whether the data should or should not be pooled; we decided in favour of a quantitative synthesis to provide a rough impression about the effect sizes achievable with US-based triage algorithms. We pooled mortality data from three trials involving 1254 patients; the RR in favour of the FAST arm was 1.00 (95% CI 0.50 to 2.00). FAST-based pathways reduced the number of CT scans (random-effects model RD -0.52, 95% CI -0.83 to -0.21), but the meaning of this result was unclear. The experimental evidence justifying FAST-based clinical pathways in diagnosing patients with suspected abdominal or multiple blunt trauma remains poor. Because of strong heterogeneity between the trial results, the quantitative information provided by this review may only be used in an exploratory fashion. It is unlikely that FAST will ever be investigated by means of a confirmatory, large-scale RCT in the future. Thus, this Cochrane Review may be regarded as a review which provides the best available evidence for clinical practice guidelines and management recommendations. It can only be concluded from the few head-to-head studies that negative US scans are likely to reduce the incidence of MDCT scans which, given the low sensitivity of FAST (or reliability of negative results), may adversely affect the diagnostic yield of the trauma survey. At best, US has no negative impact on mortality or morbidity. Assuming that major blunt abdominal or multiple trauma is associated with 15% mortality and a CT-based diagnostic work-up is considered the current standard of care, 874, 3495, or 21,838 patients are needed per intervention group to demonstrate non-inferiority of FAST to CT-based algorithms with non-inferiority margins of 5%, 2.5%, and 1%, power of 90%, and a type-I error alpha of 5%.

  14. Value of ultrasonography for detecting chronic injury of the lateral ligaments of the ankle joint compared with ultrasonography findings.

    PubMed

    Cheng, Y; Cai, Y; Wang, Y

    2014-01-01

    The aim of this study was to assess the accuracy of ultrasonography in the diagnosis of chronic lateral ankle ligament injury. A total of 120 ankles in 120 patients with a clinical suspicion of chronic ankle ligament injury were examined by ultrasonography by using a 5- to 17-MHz linear array transducer before surgery. The results of ultrasonography were compared with the operative findings. There were 18 sprains and 24 partial and 52 complete tears of the anterior talofibular ligament (ATFL); 26 sprains, 27 partial and 12 complete tears of the calcaneofibular ligament (CFL); and 1 complete tear of the posterior talofibular ligament (PTFL) at arthroscopy and operation. Compared with operative findings, the sensitivity, specificity and accuracy of ultrasonography were 98.9%, 96.2% and 84.2%, respectively, for injury of the ATFL and 93.8%, 90.9% and 83.3%, respectively, for injury of the CFL. The PTFL tear was identified by ultrasonography. The accuracy of identification between acute-on-chronic and subacute-chronic patients did not differ. The accuracies of diagnosing three grades of ATFL injuries were almost the same as those of diagnosing CFL injuries. Ultrasonography provides useful information for the evaluation of patients presenting with chronic pain after ankle sprain. Intraoperative findings are the reference standard. We demonstrated that ultrasonography was highly sensitive and specific in detecting chronic lateral ligments injury of the ankle joint.

  15. Value of ultrasonography for detecting chronic injury of the lateral ligaments of the ankle joint compared with ultrasonography findings

    PubMed Central

    Cheng, Y; Cai, Y

    2014-01-01

    Objective: The aim of this study was to assess the accuracy of ultrasonography in the diagnosis of chronic lateral ankle ligament injury. Methods: A total of 120 ankles in 120 patients with a clinical suspicion of chronic ankle ligament injury were examined by ultrasonography by using a 5- to 17-MHz linear array transducer before surgery. The results of ultrasonography were compared with the operative findings. Results: There were 18 sprains and 24 partial and 52 complete tears of the anterior talofibular ligament (ATFL); 26 sprains, 27 partial and 12 complete tears of the calcaneofibular ligament (CFL); and 1 complete tear of the posterior talofibular ligament (PTFL) at arthroscopy and operation. Compared with operative findings, the sensitivity, specificity and accuracy of ultrasonography were 98.9%, 96.2% and 84.2%, respectively, for injury of the ATFL and 93.8%, 90.9% and 83.3%, respectively, for injury of the CFL. The PTFL tear was identified by ultrasonography. The accuracy of identification between acute-on-chronic and subacute–chronic patients did not differ. The accuracies of diagnosing three grades of ATFL injuries were almost the same as those of diagnosing CFL injuries. Conclusion: Ultrasonography provides useful information for the evaluation of patients presenting with chronic pain after ankle sprain. Advances in knowledge: Intraoperative findings are the reference standard. We demonstrated that ultrasonography was highly sensitive and specific in detecting chronic lateral ligments injury of the ankle joint. PMID:24352708

  16. Comprasion of ovarian stromal blood flow measured by color Doppler ultrasonography in polycystic ovary syndrome patients and healthy women with ultrasonographic evidence of polycystic.

    PubMed

    Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat

    2015-04-01

    To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p < 0.05). 3-D ovarian volumes were found significantly higher in patients with PCOS (p < 0.05), and a negative correlation was also obtained between ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.

  17. (18)F-FDG uptake predicts diagnostic yield of transbronchial biopsy in peripheral lung cancer.

    PubMed

    Umeda, Yukihiro; Demura, Yoshiki; Anzai, Masaki; Matsuoka, Hiroki; Araya, Tomoyuki; Nishitsuji, Masaru; Nishi, Koichi; Tsuchida, Tatsuro; Sumida, Yasuyuki; Morikawa, Miwa; Ameshima, Shingo; Ishizaki, Takeshi; Kasahara, Kazuo; Ishizuka, Tamotsu

    2014-07-01

    Recent advances in endobronchial ultrasonography with a guide sheath (EBUS-GS) have enabled better visualization of distal airways, while virtual bronchoscopic navigation (VBN) has been shown useful as a guide to navigate the bronchoscope. However, indications for utilizing VBN and EBUS-GS are not always clear. To clarify indications for a bronchoscopic examination using VBN and EBUS-GS, we evaluated factors that predict the diagnostic yield of a transbronchial biopsy (TBB) procedure for peripheral lung cancer (PLC) lesions. We retrospectively reviewed the charts of 194 patients with 201 PLC lesions (≤3cm mean diameter), and analyzed the association of diagnostic yield of TBB with [(18)F]-fluoro-2-deoxy-d-glucose ((18)F-FDG) positron emission tomography and chest computed tomography (CT) findings. The diagnostic yield of TBB using VBN and EBUS-GS was 66.7%. High maximum standardized uptake value (SUVmax), positive bronchus sign, and ground-glass opacity component shown on CT were all significant predictors of diagnostic yield, while multivariate analysis showed only high (18)F-FDG uptake (SUVmax ≥2.8) and positive bronchus sign as significant predictors. Diagnostic yield was higher for PLC lesions with high (18)F-FDG uptake (SUVmax ≥2.8) and positive bronchus sign (84.6%) than for those with SUVmax <2.8 and negative bronchus sign (33.3%). High (18)F-FDG uptake was also correlated with tumor invasiveness. High (18)F-FDG uptake predicted the diagnostic yield of TBB using VBN and EBUS-GS for PLC lesions. (18)F-FDG uptake and bronchus sign may indicate for the accurate application of bronchoscopy with those modalities for diagnosing PLC. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial

    PubMed Central

    Di Santo, Pietro; Harnett, David T.; Simard, Trevor; Ramirez, F. Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G.; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong

    2018-01-01

    BACKGROUND: Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. METHODS: We compared the modified Allen test with a smartphone heart rate–monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient’s index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate–monitoring application. RESULTS: Among 438 patients who were included in the study, we found that the heart rate–monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). INTERPRETATION: A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient’s bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. PMID:29615421

  19. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial.

    PubMed

    Di Santo, Pietro; Harnett, David T; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong; Hibbert, Benjamin

    2018-04-03

    Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. We compared the modified Allen test with a smartphone heart rate-monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient's index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate-monitoring application. Among 438 patients who were included in the study, we found that the heart rate-monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient's bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. © 2018 Joule Inc. or its licensors.

  20. Diagnostic criteria for hepatocellular carcinoma ⩽3 cm with hepatocyte-specific contrast-enhanced magnetic resonance imaging.

    PubMed

    Choi, Sang Hyun; Byun, Jae Ho; Lim, Young-Suk; Yu, Eunsil; Lee, So Jung; Kim, So Yeon; Won, Hyung Jin; Shin, Yong Moon; Kim, Pyo Nyun

    2016-05-01

    Current diagnostic imaging criteria for hepatocellular carcinoma (HCC) are dedicated to imaging with nonspecific extracellular contrast agents. This study aimed to evaluate diagnostic criteria for HCC ⩽3 cm on magnetic resonance imaging (MRI) with a hepatocyte-specific contrast agent through an inception cohort study. Of 291 patients with chronic liver disease and new nodules of 1-3 cm in diameter at surveillance ultrasonography, 295 solid nodules (194 HCCs, 98 benign nodules, and three other malignancies) in 198 patients with a confirmed final diagnosis or ⩾24 months follow-up were evaluated on gadoxetic acid-enhanced MRI. Through univariate and multivariate logistic regression analyses, various diagnostic criteria were developed by combining significant MRI findings for diagnosing HCC. The diagnostic performance of each criterion was compared with that of the European Association for the Study of the Liver (EASL) criteria. Four MRI findings (arterial-phase hyperintensity, transitional-phase hypointensity, hepatobiliary-phase hypointensity, and rim enhancement) were independently significant for diagnosis of HCC ⩽3 cm. For whole nodules, EASL criteria showed the best performance for diagnosing HCC (sensitivity, 83.5%; specificity, 81.2%). For nodules ⩽2 cm in diameter, a new criterion (arterial-phase hyperintensity and hepatobiliary-phase hypointensity) showed a significantly higher sensitivity than that of the EASL criteria (83.0% vs. 74.5%, p=0.008), without a significantly different specificity (76.7% vs. 81.1%, p=0.125). EASL criteria exhibit the best diagnostic performance for HCC ⩽3 cm on hepatocyte-specific contrast-enhanced MRI. A newly identified criterion (arterial-phase hyperintensity and hepatobiliary-phase hypointensity) may increase the diagnostic sensitivity of small (⩽2 cm) HCC. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  1. Human prenatal diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filkins, K.; Russo, J.F.

    Advances in the field of prenatal diagnosis have been rapid during the past decade. Moreover, liberal use of birth control methods and restriction of family size have placed greater emphasis on optimum outcome of each pregnancy. There are many prenatal diagnostic techniques of proven value; the risks, including false negatives and false positives, are known. With the rapid proliferation of new and experimental techniques, many disorders are potential diagnosable or even treatable; however, risk factors are unknown and issues relating to quality control have not been resolved. These problems are readily appreciated in the dramatic new techniques involving recombinant DNA,more » chorion villus sampling, and fetal surgery. Unfortunately, clinicians may not appreciate the difficulties that may also be encountered in the more mundane prenatal diagnostic tests such as ultrasonography or enzymatic testing. The aim of this volume is to clarify and rationalize certain aspects of diagnosis, genetic counseling, and intervention. New and experimental techniques are presented in the light of current knowledge.« less

  2. CT Dose Optimization in Pediatric Radiology: A Multiyear Effort to Preserve the Benefits of Imaging While Reducing the Risks.

    PubMed

    Greenwood, Taylor J; Lopez-Costa, Rodrigo I; Rhoades, Patrick D; Ramírez-Giraldo, Juan C; Starr, Matthew; Street, Mandie; Duncan, James; McKinstry, Robert C

    2015-01-01

    The marked increase in radiation exposure from medical imaging, especially in children, has caused considerable alarm and spurred efforts to preserve the benefits but reduce the risks of imaging. Applying the principles of the Image Gently campaign, data-driven process and quality improvement techniques such as process mapping and flowcharting, cause-and-effect diagrams, Pareto analysis, statistical process control (control charts), failure mode and effects analysis, "lean" or Six Sigma methodology, and closed feedback loops led to a multiyear program that has reduced overall computed tomographic (CT) examination volume by more than fourfold and concurrently decreased radiation exposure per CT study without compromising diagnostic utility. This systematic approach involving education, streamlining access to magnetic resonance imaging and ultrasonography, auditing with comparison with benchmarks, applying modern CT technology, and revising CT protocols has led to a more than twofold reduction in CT radiation exposure between 2005 and 2012 for patients at the authors' institution while maintaining diagnostic utility. (©)RSNA, 2015.

  3. Comparison of ultrasonography, radiography and a single computed tomography slice for the identification of fluid within the tympanic bulla of rabbit cadavers.

    PubMed

    King, A M; Posthumus, J; Hammond, G; Sullivan, M

    2012-08-01

    Evaluation of the tympanic bulla (TB) in cases of otitis media in the rabbit can be a diagnostic challenge, although a feature often associated with the condition is the accumulation of fluid or material within the TB. Randomly selected TB from 40 rabbit cadavers were filled with a water-based, water-soluble jelly lubricant. A dorsoventral radiograph and single computed tomography (CT) slice were taken followed by an ultrasound (US) examination. Image interpretation was performed by blinded operators. The content of each TB was determined (fluid or gas) using each technique and the cadavers were frozen and sectioned for confirmation. CT was the most accurate diagnostic method, but US produced better results than radiography. Given the advantages of US over the other imaging techniques, the results suggest that further work is warranted to determine US applications in the evaluation of the rabbit TB and clinical cases of otitis media in this species. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Local ablation therapy with contrast-enhanced ultrasonography for hepatocellular carcinoma: a practical review

    PubMed Central

    Kim, Tae Kyoung; Khalili, Korosh; Jang, Hyun-Jung

    2015-01-01

    A successful program for local ablation therapy for hepatocellular carcinoma (HCC) requires extensive imaging support for diagnosis and localization of HCC, imaging guidance for the ablation procedures, and post-treatment monitoring. Contrast-enhanced ultrasonography (CEUS) has several advantages over computed tomography/magnetic resonance imaging (CT/MRI), including real-time imaging capability, sensitive detection of arterial-phase hypervascularity and washout, no renal excretion, no ionizing radiation, repeatability, excellent patient compliance, and relatively low cost. CEUS is useful for image guidance for isoechoic lesions. While contrast-enhanced CT/MRI is the standard method for the diagnosis of HCC and post-ablation monitoring, CEUS is useful when CT/MRI findings are indeterminate or CT/MRI is contraindicated. This article provides a practical review of the role of CEUS in imaging algorithms for pre- and post-ablation therapy for HCC. PMID:26169081

  5. Histogram-based quantitative evaluation of endobronchial ultrasonography images of peripheral pulmonary lesion.

    PubMed

    Morikawa, Kei; Kurimoto, Noriaki; Inoue, Takeo; Mineshita, Masamichi; Miyazawa, Teruomi

    2015-01-01

    Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p < 0.01). With a cutoff value for standard deviation of 10.5, lung cancer could be diagnosed with an accuracy of 81.7%. Other characteristics investigated were inferior when compared to histogram standard deviation. Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images. © 2015 S. Karger AG, Basel.

  6. Sonographic diagnosis of carpal tunnel syndrome: a study in 200 hospital workers*

    PubMed Central

    Castro, Adham do Amaral e; Skare, Thelma Larocca; Nassif, Paulo Afonso Nunes; Sakuma, Alexandre Kaue; Barros, Wagner Haese

    2015-01-01

    Objective To describe the prevalence of carpal tunnel syndrome in a sample of 200 healthy hospital workers, establishing the respective epidemiological associations. Materials and Methods Two hundred individuals were submitted to wrist ultrasonography to measure the median nerve area. They were questioned and examined for epidemiological data, body mass index, carpal tunnel syndrome signs and symptoms, and submitted to the Boston carpal tunnel questionnaire (BCTQ) to evaluate the carpal tunnel syndrome severity. A median nerve area ≥ 9 mm2 was considered to be diagnostic of carpal tunnel syndrome. Results Carpal tunnel syndrome was diagnosed by ultrasonography in 34% of the sample. It was observed the association of carpal tunnel syndrome with age (p < 0.0001), paresthesia (p < 0.0001), Tinel’s test (p < 0.0001), Phalen’s test (p < 0.0001), BCTQ score (p < 0.0001), and years of formal education (p < 0.0001). Years of formal education was the only variable identified as an independent risk factor for carpal tunnel syndrome (95% CI = 1.03 to 1.24). Conclusion The prevalence of carpal tunnel syndrome in a population of hospital workers was of 34%. The number of years of formal education was the only independent risk factor for carpal tunnel syndrome. PMID:26543279

  7. Ultrasonography of uterine leiomyomas

    PubMed Central

    Woźniak, Andrzej

    2017-01-01

    Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan – TVS) or transabdominally (transabdominal scan – TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus. PMID:29483851

  8. Lung ultrasonography of pulmonary complications in preterm infants with respiratory distress syndrome.

    PubMed

    Lovrenski, Jovan

    2012-03-01

    To evaluate the diagnostic possibilities of lung ultrasonography (LUS) in detecting pulmonary complications in preterm infants with respiratory distress syndrome (RDS). A prospective study included 120 preterm infants with clinical and radiographic signs of RDS. LUS was performed using both a transthoracic and a transabdominal approach within the first 24 h of life, and, after that, follow-up LUS examinations were performed. In 47 detected pulmonary complications of RDS (hemorrhage, pneumothorax, pneumonia, atelectasis, bronchopulmonary dysplasia), comparisons between LUS and chest X-ray (CXR) were made. Also, 90 subpleural consolidations registered during LUS examinations were analysed. Statistical analysis included MANOVA and discriminant analysis, t-test, confidence interval, and positive predictive value. In 45 of 47 instances the same diagnosis of complication was detected with LUS as with CXR, indicating a high reliability of the method in premature infants with RDS. The only two false negative findings concerned partial pneumothorax. The positive predictive value of LUS was 100%. A statistically significant difference of LUS findings between the anterior and posterior lung areas was observed in both right and left hemithoraces. LUS enables the detection of pulmonary complications in preterm infants with RDS and has the potential to reduce the number of CXRs. The specific guidelines for its use should be provided in a more extensive study.

  9. Determining the sensitivity of transrectal ultrasonography on a consecutive series of prostate cancers in a clinical and screening setting.

    PubMed

    Ciatto, Stefano; Bonardi, Rita; Lombardi, Claudio; Zappa, Marco; Gervasi, Ginetta

    2002-01-01

    To evaluate the sensitivity at transrectal ultrasonography (TRUS) for prostate cancer. A consecutive series of 170 prostate cancers identified by matching local cancer registry and TRUS archives at the Centro per lo Studio e la Prevenzione Oncologica of Florence. TRUS sensitivity was determined as the ratio of TRUS positive to total prostate cancers occurring at different intervals from TRUS date. Univariate and multivariate analyses of sensitivity determinants were performed. Sensitivity at 6 months, 1, 2 and 3 years after the test was 94.1% (95% CI, 90-98), 89.8% (95% CI, 85-95), 80.4% (95% CI, 74-87) and 74.1% (95% CI, 68-81%), respectively. A higher sensitivity (statistically significant) of TRUS was observed only if digital rectal examination was suspicious, whereas no association to sensitivity was observed for age, prostate-specific antigen or prostate-specific antigen density. The study provided a reliable estimate of TRUS sensitivity, particularly reliable being checked against a cancer registry: observed sensitivity was high, at least of the same magnitude of other cancer screening tests. TRUS, which is known to allow for considerable diagnostic anticipation and is more specific than prostate-specific antigen, might still be considered for its contribution to a screening approach.

  10. Real-time 3-dimensional contrast-enhanced ultrasound in detecting hemorrhage of blunt renal trauma.

    PubMed

    Xu, Rui-Xue; Li, Ye-Kuo; Li, Ting; Wang, Sha-Sha; Yuan, Gui-Zhong; Zhou, Qun-Fang; Zheng, Hai-Rong; Yan, Fei

    2013-10-01

    The objective of this study is to evaluate the diagnostic value of real-time 3-dimensional contrast-enhanced ultrasound in the hemorrhage of blunt renal trauma. Eighteen healthy New Zealand white rabbits were randomly divided into 3 groups. Blunt renal trauma was performed on each group by using minitype striker. Ultrasonography, color Doppler flow imaging, and contrast-enhanced 2-dimensional and real-time 3-dimensional ultrasound were applied before and after the strike. The time to shock and blood pressure were subjected to statistical analysis. Then, a comparative study of ultrasound and pathology was carried out. All the struck kidneys were traumatic. In the ultrasonography, free fluid was found under the renal capsule. In the color Doppler flow imaging, active hemorrhage was not identified. In 2-dimensional contrast-enhanced ultrasound, active hemorrhage of the damaged kidney was characterized. Real-time 3-dimensional contrast-enhanced ultrasound showed a real-time and stereoscopic ongoing bleeding of the injured kidney. The wider the hemorrhage area in 4-dimensional contrast-enhanced ultrasound was, the faster the blood pressure decreased. Real-time 3-dimensional contrast-enhanced ultrasound is a promising noninvasive tool for stereoscopically and vividly detecting ongoing hemorrhage of blunt renal trauma in real time. © 2013.

  11. Diagnosing upper extremity deep vein thrombosis with non-contrast-enhanced Magnetic Resonance Direct Thrombus Imaging: A pilot study.

    PubMed

    Dronkers, C E A; Klok, F A; van Haren, G R; Gleditsch, J; Westerlund, E; Huisman, M V; Kroft, L J M

    2018-03-01

    Diagnosing upper extremity deep vein thrombosis (UEDVT) can be challenging. Compression ultrasonography is often inconclusive because of overlying anatomic structures that hamper compressing veins. Contrast venography is invasive and has a risk of contrast allergy. Magnetic Resonance Direct Thrombus Imaging (MRDTI) and Three Dimensional Turbo Spin-echo Spectral Attenuated Inversion Recovery (3D TSE-SPAIR) are both non-contrast-enhanced Magnetic Resonance Imaging (MRI) sequences that can visualize a thrombus directly by the visualization of methemoglobin, which is formed in a fresh blood clot. MRDTI has been proven to be accurate in diagnosing deep venous thrombosis (DVT) of the leg. The primary aim of this pilot study was to test the feasibility of diagnosing UEDVT with these MRI techniques. MRDTI and 3D TSE-SPAIR were performed in 3 pilot patients who were already diagnosed with UEDVT by ultrasonography or contrast venography. In all patients, UEDVT diagnosis could be confirmed by MRDTI and 3D TSE-SPAIR in all vein segments. In conclusion, this study showed that non-contrast MRDTI and 3D TSE-SPAIR sequences may be feasible tests to diagnose UEDVT. However diagnostic accuracy and management studies have to be performed before these techniques can be routinely used in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Diagnostic accuracy of magnetic resonance imaging, transvaginal, and transrectal ultrasonography in deep infiltrating endometriosis

    PubMed Central

    Alborzi, Saeed; Rasekhi, Alireza; Shomali, Zahra; Madadi, Gooya; Alborzi, Mahshid; Kazemi, Mahboobeh; Hosseini Nohandani, Azam

    2018-01-01

    Abstract To determine the diagnostic accuracy of pelvic magnetic resonance imaging (MRI), transvaginal sonography (TVS), and transrectal sonography (TRS) in diagnosis of deep infiltrating endometriosis (DIE). This diagnostic accuracy study was conducted during a 2-year period including a total number of 317 patients with signs and symptoms of endometriosis. All the patients were evaluated by pelvic MRI, TVS, and TRS in the same center. The criterion standard was considered to be the laparoscopy and histopathologic examination. Of 317 patients being included in the present study, 252 tested positive for DIE. The sensitivity, specificity, positive predictive value, and negative predictive value of TVS was found to be 83.3%, 46.1%, 85.7%, and 41.6%, respectively. These variables were 80.5%, 18.6%, 79.3%, and 19.7% for TRS and 90.4%, 66.1%, 91.2%, and 64.1% for MRI, respectively. MRI had the highest accuracy (85.4%) when compared to TVS (75.7%) and TRS (67.8%). The sensitivity of TRS, TVS, and MRI in uterosacral ligament DIE was 82.8%, 70.9%, and 63.6%, respectively. On the contrary, specificity had a reverse trend, favoring MRI (93.9%, 92.8%, and 89.8% for TVS and TRS, respectively). The results of the present study demonstrated that TVS and TRS have appropriate diagnostic accuracy in diagnosis of DIE comparable to MRI. PMID:29465552

  13. Diagnostic accuracy of ultrasonography and magnetic resonance imaging for the detection of fetal anomalies: a blinded case–control study

    PubMed Central

    Gonçalves, L. F.; Lee, W.; Mody, S.; Shetty, A.; Sangi-Haghpeykar, H.; Romero, R.

    2018-01-01

    Objectives To compare the accuracy of two-dimensional ultrasound (2D-US), three-dimensional ultrasound (3D-US) and magnetic resonance imaging (MRI) for the diagnosis of congenital anomalies without prior knowledge of indications and previous imaging findings. Methods This was a prospective, blinded case–control study comprising women with a singleton pregnancy with fetal congenital abnormalities identified on clinical ultrasound and those with an uncomplicated pregnancy. All women volunteered to undergo 2D-US, 3D-US and MRI, which were performed at one institution. Different examiners at a collaborating institution performed image interpretation. Sensitivity and specificity of the three imaging methods were calculated for individual anomalies, based on postnatal imaging and/or autopsy as the definitive diagnosis. Diagnostic confidence was graded on a four-point Likert scale. Results A total of 157 singleton pregnancies were enrolled, however nine cases were excluded owing to incomplete outcome, resulting in 148 fetuses (58 cases and 90 controls) included in the final analysis. Among cases, 13 (22.4%) had central nervous system (CNS) anomalies, 40 (69.0%) had non-CNS anomalies and five (8.6%) had both CNS and non-CNS anomalies. The main findings were: (1) MRI was more sensitive than 3D-US for diagnosing CNS anomalies (MRI, 88.9% (16/18) vs 3D-US, 66.7% (12/18) vs 2D-US, 72.2% (13/18); McNemar’s test for MRI vs 3D-US: P=0.046); (2) MRI provided additional information affecting prognosis and/or counseling in 22.2% (4/18) of fetuses with CNS anomalies; (3) 2D-US, 3D-US and MRI had similar sensitivity for diagnosing non-CNS anomalies; (4) specificity for all anomalies was highest for 3D-US (MRI, 85.6% (77/90) vs 3D-US, 94.4% (85/90) vs 2D-US, 92.2% (83/90); McNemar’s test for MRI vs 3D-US: P=0.03); and (5) the confidence of MRI for ruling out certain CNS abnormalities (usually questionable for cortical dysplasias or hemorrhage) that were not confirmed after delivery was lower than it was for 2D-US and 3D-US. Conclusions MRI was more sensitive than ultrasonography and provided additional information that changed prognosis, counseling or management in 22.2% of fetuses with CNS anomalies. False-positive diagnoses for subtle CNS findings were higher with MRI than with ultrasonography. PMID:26444861

  14. Magnetic Resonance Imaging Verification of a Case of Sacrococcygeal Teratoma.

    PubMed

    Dedushi, Kreshnike; Kabashi, Serbeze; Mucaj, Sefedin; Ramadani, Naser; Hoxhaj, Astrit; Shatri, Jeton; Hasbahta, Gazmend

    2016-08-01

    Although rare, sacrococcygeal teratoma is the most common congenital neoplasm, occurring in 1 in 40,000 infants. Approximately 75% of affected infants are female. The aim of the present study was to correlate ultrasonography and magnetic resonance imaging (MRI) findings in patients with fetal sacrococcygeal teratoma. Three pregnant women in 27th week of gestation underwent fetal MRI after ultrasonography examination, with findings suggestive for fetal sacrococcygeal teratoma. Tumor size, location, extent and content were evaluated both by MRI and ultrasonography. Findings regarding tumor location, size and content were similar for both methods. There was a large well-circumscribed mixed, cystic/solid oval mass, originating from right sacro-gluteal region and projecting into the amniotic cavity, 132 × 110 × 76 mm in size. The mass had a heterogeneous appearance. The T1 high signal suggested fat component of the tumor, while T1 and T2 hypointense components suggested calcified/bony components. There was also T1 hypointense component consistent with cystic and fluid component. The imaging findings were characteristic for sacrococcygeal teratoma. There was not obvious lumbar or thoracic spinal involvement. There was no gross intrapelvic or abdominal extension, and even sacrum and coccyx appeared deformed. The amount of amniotic fluid was increased. MRI was superior to ultrasonography in the evaluation of the exact tumor extent, accurately demonstrating pelvic involvement in all of the three cases. Fetal MRI has shown to be a valuable adjunct to obstetric sonography in the evaluation of fetal sacrococcygeal teratoma, because of its higher accuracy in the determination of tumors extent and content, playing a significant role in the therapeutic planning and increasing the chances of cure for these fetuses.

  15. Magnetic Resonance Imaging Verification of a Case of Sacrococcygeal Teratoma

    PubMed Central

    Dedushi, Kreshnike; Kabashi, Serbeze; Mucaj, Sefedin; Ramadani, Naser; Hoxhaj, Astrit; Shatri, Jeton; Hasbahta, Gazmend

    2016-01-01

    Although rare, sacrococcygeal teratoma is the most common congenital neoplasm, occurring in 1 in 40,000 infants. Approximately 75% of affected infants are female. The aim of the present study was to correlate ultrasonography and magnetic resonance imaging (MRI) findings in patients with fetal sacrococcygeal teratoma. Three pregnant women in 27th week of gestation underwent fetal MRI after ultrasonography examination, with findings suggestive for fetal sacrococcygeal teratoma. Tumor size, location, extent and content were evaluated both by MRI and ultrasonography. Findings regarding tumor location, size and content were similar for both methods. There was a large well-circumscribed mixed, cystic/solid oval mass, originating from right sacro-gluteal region and projecting into the amniotic cavity, 132 × 110 × 76 mm in size. The mass had a heterogeneous appearance. The T1 high signal suggested fat component of the tumor, while T1 and T2 hypointense components suggested calcified/bony components. There was also T1 hypointense component consistent with cystic and fluid component. The imaging findings were characteristic for sacrococcygeal teratoma. There was not obvious lumbar or thoracic spinal involvement. There was no gross intrapelvic or abdominal extension, and even sacrum and coccyx appeared deformed. The amount of amniotic fluid was increased. MRI was superior to ultrasonography in the evaluation of the exact tumor extent, accurately demonstrating pelvic involvement in all of the three cases. Fetal MRI has shown to be a valuable adjunct to obstetric sonography in the evaluation of fetal sacrococcygeal teratoma, because of its higher accuracy in the determination of tumors extent and content, playing a significant role in the therapeutic planning and increasing the chances of cure for these fetuses. PMID:28983369

  16. Updated ultrasound criteria for polycystic ovary syndrome: reliable thresholds for elevated follicle population and ovarian volume.

    PubMed

    Lujan, Marla E; Jarrett, Brittany Y; Brooks, Eric D; Reines, Jonathan K; Peppin, Andrew K; Muhn, Narry; Haider, Ehsan; Pierson, Roger A; Chizen, Donna R

    2013-05-01

    Do the ultrasonographic criteria for polycystic ovaries supported by the 2003 Rotterdam consensus adequately discriminate between the normal and polycystic ovary syndrome (PCOS) condition in light of recent advancements in imaging technology and reliable methods for estimating follicle populations in PCOS? Using newer ultrasound technology and a reliable grid system approach to count follicles, we concluded that a substantially higher threshold of follicle counts throughout the entire ovary (FNPO)-26 versus 12 follicles-is required to distinguish among women with PCOS and healthy women from the general population. The Rotterdam consensus defined the polycystic ovary as having 12 or more follicles, measuring between 2 and 9 mm (FNPO), and/or an ovarian volume (OV) >10 cm(3). Since their initial proposal in 2003, a heightened prevalence of polycystic ovaries has been described in healthy women with regular menstrual cycles, which has questioned the accuracy of these criteria and marginalized the specificity of polycystic ovaries as a diagnostic criterion for PCOS. A diagnostic test study was performed using cross-sectional data, collected from 2006 to 2011, from 168 women prospectively evaluated by transvaginal ultrasonography. Receiver operating characteristic (ROC) curve analyses were performed to determine the appropriate diagnostic thresholds for: (i) FNPO, (ii) follicle counts in a single cross section (FNPS) and (iii) OV. The levels of intra- and inter-observer reliability when five observers used the proposed criteria on 100 ultrasound cases were also determined. Ninety-eight women diagnosed with PCOS by the National Institutes of Health criteria as having both oligo-amenorrhea and hyperandrogenism and 70 healthy female volunteers recruited from the general population. Participants were evaluated by transvaginal ultrasonography at the Royal University Hospital within the Department of Obstetrics, Gynecology and Reproductive Sciences, University of Saskatchewan (Saskatoon, SK, Canada) and in the Division of Nutritional Sciences' Human Metabolic Research Unit, Cornell University (Ithaca, NY, USA). Diagnostic potential for PCOS was highest for FNPO (0.969), followed by FNPS (0.880) and OV (0.873) as judged by the area under the ROC curve. An FNPO threshold of 26 follicles had the best compromise between sensitivity (85%) and specificity (94%) when discriminating between controls and PCOS. Similarly, an FNPS threshold of nine follicles had a 69% sensitivity and 90% specificity, and an OV of 10 cm(3) had a 81% sensitivity and 84% specificity. Levels of intra-observer reliability were 0.81, 0.80 and 0.86 when assessing FNPO, FNPS and OV, respectively. Inter-observer reliability was 0.71, 0.72 and 0.82, respectively. Thresholds proposed by this study should be limited to use in women aged between 18 and 35 years. Polycystic ovarian morphology has excellent diagnostic potential for detecting PCOS. FNPO have better diagnostic potential and yield greater diagnostic confidence compared with assessments of FNPS or OV. Whenever possible, images throughout the entire ovary should be collected for the ultrasonographic evaluation of PCOS. This study was funded by Cornell University and fellowship awards from the Saskatchewan Health Research Foundation and Canadian Institutes of Health Research. The authors have no conflict of interests to disclose.

  17. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer.

    PubMed

    Ueda, Shigeto; Tsuda, Hitoshi; Asakawa, Hideki; Omata, Jiro; Fukatsu, Kazuhiko; Kondo, Nobuo; Kondo, Tadaharu; Hama, Yukihiro; Tamura, Katsumi; Ishida, Jiro; Abe, Yoshiyuki; Mochizuki, Hidetaka

    2008-06-09

    Accurate evaluation of axillary lymph node (ALN) involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (18F-FDG PET/CT) and axillary ultrasonography (AUS) for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB) and preoperative systemic chemotherapy (PSC). One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND). Using 18F-FDG PET/CT, we studied both a visual assessment of 18F-FDG uptake and standardized uptake value (SUV) for axillary staging. In a visual assessment of 18F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12) in 18F-FDG PET uptake only, 80% (4 of 5) in AUS positive only, and 100% (28 of 28) in dual positive. By the combination of AUS and 18F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03). The diagnostic accuracy of 18F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their limited sensitivities, the high radiation exposure by 18F-FDG PET/CT and also costs of the examination, it is likely that AUS will be more cost-effective in detecting massive axillary tumor burden. However, when we cannot judge the axillary staging using AUS alone, metabolic approach of 18F-FDG PET/CT for axillary staging would enable us a much more confident diagnosis.

  18. A Case of Unicornuate Uterus with Atypical Located Hyperstimulated Ovary after in Vitro Fertilization Pre-Embryo Transfer (IVF-ET)

    PubMed Central

    Angelova, Mariya Angelova; Kovachev, Emil Georgiev; Kisyov, Stefan Vasilev; Ivanova, Vilislava Robert

    2015-01-01

    The authors describe a case of a congenital Mullerian anomaly, uterus unicornis with missing right fallopian tube. An in Vitro Fertilization Pre-Embryo Transfer (IVF-ET) procedure was done and presently is known that the patient has left fallopian tube and left ovary, two kidneys, and right ovary is missing. No diagnostic laparoscopy and hysteroscopy were done, only hysterosalpingography (HSG) before the IVF procedure. Several days after the follicular puncture of the left ovary the patient was urgently admitted to the hospital for specialized gynaecology in Varna. Transabdominal ultrasonography showed right ovary atypically located immediately next to the liver and with emerging theca-lutein cysts. PMID:27275261

  19. Conservative treatment of massive hemothorax in a girl with neuroblastoma.

    PubMed

    Shiokawa, Naohiro; Okamoto, Yasuhiro; Kodama, Yuichi; Nishikawa, Takuro; Tanabe, Takayuki; Mukai, Motoi; Yoshioka, Takako; Kawano, Yoshifumi

    2016-10-01

    We report the case of a 1-year-old girl with stage 4 neuroblastoma who developed massive hemothorax due to tumor invasion before treatment. She presented with tachypnea, worsening anemia, and oxygen desaturation. Hemothorax was diagnosed based on chest radiography, ultrasonography, and diagnostic thoracic puncture results. High neuron-specific enolase, vanillylmandelic acid, and homovanillic acid as well as computed tomography strongly supported a diagnosis of neuroblastoma. Chemotherapy along with intermittent puncture drainage, oxygen, and blood transfusion reduced the accumulated blood, and hemothorax disappeared within 1 week. Thus, it is possible to avoid invasive treatment for massive hemothorax by initiating chemotherapy for chemosensitive solid tumors, including neuroblastoma. © 2016 Japan Pediatric Society.

  20. Recommendations of diagnosis and treatment of pleural effusion. Update.

    PubMed

    Villena Garrido, Victoria; Cases Viedma, Enrique; Fernández Villar, Alberto; de Pablo Gafas, Alicia; Pérez Rodríguez, Esteban; Porcel Pérez, José Manuel; Rodríguez Panadero, Francisco; Ruiz Martínez, Carlos; Salvatierra Velázquez, Angel; Valdés Cuadrado, Luis

    2014-06-01

    Although during the last few years there have been several important changes in the diagnostic or therapeutic methods, pleural effusion is still one of the diseases that the respiratory specialist have to evaluate frequently. The aim of this paper is to update the knowledge about pleural effusions, rather than to review the causes of pleural diseases exhaustively. These recommendations have a longer extension for the subjects with a direct clinical usefulness, but a slight update of other pleural diseases has been also included. Among the main scientific advantages are included the thoracic ultrasonography, the intrapleural fibrinolytics, the pleurodesis agents, or the new pleural drainages techniques. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  1. Management of mediastinal syndromes in pediatrics: a new challenge of ultrasound guidance to avoid high-risk general anesthesia.

    PubMed

    Sola, Chrystelle; Choquet, Olivier; Prodhomme, Olivier; Capdevila, Xavier; Dadure, Christophe

    2014-05-01

    Adverse events associated with anesthetic management of anterior mediastinal masses in pediatrics are common. To avoid an extremely hazardous general anesthesia, the use of real-time ultrasonography offers an effective alternative in high-risk cases. We report the anesthetic management including a light sedation and ultrasound guidance for regional anesthesia, surgical node biopsy, and placement of a central venous line in two children with an anterior symptomatic mediastinal mass. For pediatric patients with clinical and/or radiologic signs of airway compression, ultrasound guidance provides safety technical assistance to avoid general anesthesia and should be performed for the initial diagnostic and therapeutic procedures. © 2013 John Wiley & Sons Ltd.

  2. Mycobacteriosis in a Domestic Ferret (Mustela putorius furo)

    PubMed Central

    NAKATA, Makoto; MIWA, Yasutsugu; TSUBOI, Masaya; UCHIDA, Kazuyuki

    2014-01-01

    ABSTRACT A 4-year-old spayed female ferret presented with a 2-month history of anorexia, vomiting and occasional diarrhea. Abdominal ultrasonography revealed thickening of the gastric wall and enlarged abdominal lymph nodes. Biopsy samples from the thickened gastric wall, enlarged abdominal lymph nodes and liver were taken during an exploratory laparotomy. Based on the histopathological examination, mycobacterium infection was diagnosed. The bacterial species could not be identified by additional diagnostic tests of feces, including fecal smear, culture and polymerase chain reaction (PCR). The ferret was treated with prednisolone and multiple antimicrobials, including rifampicin, azithromycin and enrofloxacin, but did not improve with treatment and died 220 days after the first presentation. PMID:24419874

  3. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center

    PubMed Central

    2012-01-01

    Background This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. Methods The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. Results The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Conclusions Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed. PMID:22691418

  4. The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center.

    PubMed

    Kim, Hyung Min; So, Byung Hak; Jeong, Won Jung; Choi, Se Min; Park, Kyu Nam

    2012-06-12

    This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed.

  5. Performance of physical examination versus ultrasonography to detect stenosis in haemodialysis arteriovenous fistula.

    PubMed

    Maldonado-Cárceles, Ana B; García-Medina, José; Torres-Cantero, Alberto M

    2017-01-18

    The overall purpose of this study is to compare the accuracy of physical examination (PE) versus ultrasonography (US) in people with arteriovenous fistula (AVF). This is a cross-sectional study with a total of 99 patients attended by the vascular radiology unit for AVF evaluation during January - March 2015. PE and ultrasonography were blinded performed by different radiologists. For complete and individual signs of PE, sensitivity, specificity, predictive positive (PPV) and negative (PNV) value, likelihood ratios (LR) and Cohen's κ value were measured. According to ultrasonography, the presence of stenosis was identified in 57 (58%) patients, and 61 (62%) by PE. The accuracy of PE for the diagnosis of AVF was sensitivity 82%, specificity 67%, PPV 77%, NPV 74%, LR 2.74 and 0.26. There was a moderate agreement beyond chance between PE and ultrasonography (κ = 0.5). PE has shown a moderate accuracy to detect stenosis. With non-ultrasonography availability Haemodialysis Units can get benefit to optimize VA survival and professionals should improve its basic skills.

  6. Causes of altered liver function tests - the role of alpha-1 antitrypsin.

    PubMed

    Stollenwerk, J; Schepke, M; Biecker, E

    2016-09-01

    Altered liver function tests are a common finding in clinical practice. Our retrospective study aimed to identify the diagnoses in a non-selected cohort of patients with altered liver tests and to investigate whether alpha-1 antitrypsin genotyping should be part of the diagnostic workup. 501 patients who were admitted to our outpatient clinic for further evaluation of altered liver function tests were included in the study. The patients underwent a standardized diagnostic program with history taking, physical examination, laboratory tests and ultrasonography. Liver biopsy was performed if appropriate. More than 50 % of the patients had nonalcoholic fatty liver disease. Alcoholic and drug-induced liver injury were found in 8.6 % and 7 % of patients, respectively. Chronic hepatitis B and C, autoimmune liver disease and inherited causes of liver disease made up for approximately 16 % of the diagnoses. The remaining patients were diagnosed with kryptogenic liver disease or had miscellaneous diagnoses. In 3.7 % of the genotyped patients, the alpha-1 antitrypsin genotype PiMZ was found. Nonalcoholic fatty liver disease is nowadays the most frequent cause of altered liver tests. Alcoholic liver disease might be underrepresented in our study since these patients less often seek medical attention or the diagnosis is already made by the primary care physician. Drug-induced liver injury was found in more patients than expected and might therefore be underdiagnosed in practice. The alpha-1 antitrypsin genotype PiMZ was found in absence of other possible causes of liver disease, indicating that the PiMZ genotype is itself a risk factor for liver disease. Genotyping for alpha-1 antitrypsin should therefore be done when other causes for altered liver function tests have been ruled out. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Ultrasound-guided pleural access.

    PubMed

    Shojaee, Samira; Argento, A Christine

    2014-12-01

    Ultrasonography of the thorax has become a more recognized tool in pulmonary medicine, thanks to continuing clinical research that has proven its many valuable roles in the day-to-day management of pulmonary and pleural diseases. Ultrasound examination is a cost-effective imaging modality that permits the pulmonologist to obtain information about the pathologies in the thorax without the risk of exposure to ionizing radiation, providing the examiner with real-time and immediate results. Its ease of use and training along with its portability to the patient's bedside and accurate examination of the pleural space has allowed for safer pleural procedures such as thoracentesis, chest tube placement, tunneled pleural catheter placement, and medical thoracoscopy. In this review, we summarize the technique of chest ultrasonography, compare ultrasound to other frequently used thoracic imaging modalities, and focus on its use in obtaining pleural access while performing invasive pleural procedures. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Multimodality imaging of the orbit

    PubMed Central

    Hande, Pradipta C; Talwar, Inder

    2012-01-01

    The role of imaging is well established in the evaluation of orbital diseases. Ultrasonography, Computed tomography and Magnetic resonance imaging are complementary modalities, which allow direct visualization of regional anatomy, accurate localization and help to characterize lesions to make a reliable radiological diagnosis. The purpose of this pictorial essay is to highlight the imaging features of commonly encountered pathologies which involve the orbit. PMID:23599570

  9. The role of the bicipital groove in tendopathy of the long biceps tendon.

    PubMed

    Pfahler, M; Branner, S; Refior, H J

    1999-01-01

    Long biceps tendon disease is often underrated but plays an important role in anterior shoulder pain. We studied prospectively the anatomy of the bicipital groove and its relationship to clinical symptoms. Sixty-seven consecutive patients were investigated by mutual ultrasonography and radiographs of the intertubercular groove. All images were scrutinized for biceps tendon status (ultrasonography) and groove anatomy (radiography). Thirty-seven patients (21 male, 16 female, average age 48 years) had chronic anterior shoulder pain, and 30 patients (16 male, 14 female, average age 46 years) served as a control group. In 28 shoulders we found sonographic signs of tendovaginitis, and in 14 we found degenerative changes. The mean age of patients with pathologic conditions of the long biceps tendon was 40 years, significantly lower than that of the complete study group. The x-ray films revealed a great variation in the medial and total opening angle of the groove, whereas width, depth, and humeral head diameter showed sex-related differences. Radiologic signs of groove degeneration correlated in 43.6% with biceps tendon disease on the sonogram. Our study revealed statistically significant correlations between groove anatomy and long biceps tendon disease, which should be considered more while shoulder problems are evaluated.

  10. Doctoral theses in diagnostic imaging: a study of Spanish production between 1976 and 2011.

    PubMed

    Machan, K; Sendra Portero, F

    2018-05-15

    To analyze the production of doctoral theses in diagnostic imaging in Spain in the period comprising 1976 through 2011 with the aim of a) determining the number of theses and their distribution over time, b) describing the production in terms of universities and directors, and c) analyzing the content of the theses according to the imaging technique, anatomic site, and type of research used. The TESEO database was searched for "radiología" and/or "diagnóstico por imagen" and for terms related to diagnostic imaging in the title of the thesis. A total of 1036 theses related to diagnostic imaging were produced in 37 Spanish universities (mean, 29.6 theses/year; range, 4-59). A total of 963 thesis directors were identified; 10 of these supervised 10 or more theses. Most candidates and directors were men, although since the 2000-2001 academic year the number of male and female candidates has been similar. The anatomic regions most often included in diagnostic imaging theses were the abdomen (22.5%), musculoskeletal system (21.8%), central nervous system (16.4%), and neck and face (15.6%). The imaging techniques most often included were ultrasonography in the entire period (25.5%) and magnetic resonance imaging in the last 5 years. Most theses (63.8%) were related to clinical research. Despite certain limitations, the TESEO database makes it possible to analyze the production of doctoral theses in Spain effectively. The annual mean production of theses in diagnostic imaging is higher than in other medical specialties. This analysis reflects the historic evolution of imaging techniques and research in radiology as well as the development of Spanish universities. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Computer-aided US diagnosis of breast lesions by using cell-based contour grouping.

    PubMed

    Cheng, Jie-Zhi; Chou, Yi-Hong; Huang, Chiun-Sheng; Chang, Yeun-Chung; Tiu, Chui-Mei; Chen, Kuei-Wu; Chen, Chung-Ming

    2010-06-01

    To develop a computer-aided diagnostic algorithm with automatic boundary delineation for differential diagnosis of benign and malignant breast lesions at ultrasonography (US) and investigate the effect of boundary quality on the performance of a computer-aided diagnostic algorithm. This was an institutional review board-approved retrospective study with waiver of informed consent. A cell-based contour grouping (CBCG) segmentation algorithm was used to delineate the lesion boundaries automatically. Seven morphologic features were extracted. The classifier was a logistic regression function. Five hundred twenty breast US scans were obtained from 520 subjects (age range, 15-89 years), including 275 benign (mean size, 15 mm; range, 5-35 mm) and 245 malignant (mean size, 18 mm; range, 8-29 mm) lesions. The newly developed computer-aided diagnostic algorithm was evaluated on the basis of boundary quality and differentiation performance. The segmentation algorithms and features in two conventional computer-aided diagnostic algorithms were used for comparative study. The CBCG-generated boundaries were shown to be comparable with the manually delineated boundaries. The area under the receiver operating characteristic curve (AUC) and differentiation accuracy were 0.968 +/- 0.010 and 93.1% +/- 0.7, respectively, for all 520 breast lesions. At the 5% significance level, the newly developed algorithm was shown to be superior to the use of the boundaries and features of the two conventional computer-aided diagnostic algorithms in terms of AUC (0.974 +/- 0.007 versus 0.890 +/- 0.008 and 0.788 +/- 0.024, respectively). The newly developed computer-aided diagnostic algorithm that used a CBCG segmentation method to measure boundaries achieved a high differentiation performance. Copyright RSNA, 2010

  12. Clinical Effectiveness of High-Flow Nasal Cannula in Hypoxaemic Patients during Bronchoscopic Procedures.

    PubMed

    Chung, Sang Mi; Choi, Ju Whan; Lee, Young Seok; Choi, Jong Hyun; Oh, Jee Youn; Min, Kyung Hoon; Hur, Gyu Young; Lee, Sung Yong; Shim, Jae Jeong; Kang, Kyung Ho

    2018-06-19

    Bronchoscopy is a useful diagnostic and therapeutic tool. However, the clinical use of high-flow nasal cannula (HFNC) in adults with acute respiratory failure for diagnostic and invasive procedures has not been well evaluated. We present our experiences of well-tolerated diagnostic bronchoscopy as well as cases of improved saturation in hypoxaemic patients after a therapeutic bronchoscopic procedure. We retrospectively reviewed data of hypoxaemic patients who had undergone bronchoscopy for diagnostic or therapeutic purposes from October 2015 to February 2017. Ten patients (44-75 years of age) were enrolled. The clinical purposes of bronchoscopy were for diagnosis in seven patients and for intervention in three patients. For the diagnoses, we performed bronchoalveolar lavage in six patients. One patient underwent endobronchial ultrasonography with transbronchial needle aspiration of a lymph node to investigate tumour involvement. Patients who underwent bronchoscopy for therapeutic interventions had endobronchial mass or blood clot removal with cryotherapy for bleeding control. The mean saturation (SpO₂) of pre-bronchoscopy in room air was 84.1%. The lowest and highest mean saturation with HFNC during the procedure was 95% and 99.4, respectively. The mean saturation in room air post-bronchoscopy was 87.4%, which was 3.3% higher than the mean room air SpO₂ pre-bronchoscopy. Seven patients with diagnostic bronchoscopy had no hypoxic event. Three patients with interventional bronchoscopy showed improvement in saturation after the procedure. Bronchoscopy was well tolerated in all 10 cases. This study suggests that the use of HFNC in hypoxaemic patients during diagnostic and therapeutic bronchoscopy procedures has clinical effectiveness. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  13. Guideline of guidelines: asymptomatic microscopic haematuria.

    PubMed

    Linder, Brian J; Bass, Edward J; Mostafid, Hugh; Boorjian, Stephen A

    2018-02-01

    The aim of the present study was to review major organizational guidelines on the evaluation and management of asymptomatic microscopic haematuria (AMH). We reviewed the haematuria guidelines from: the American Urological Association; the consensus statement by the Canadian Urological Association, Canadian Urologic Oncology Group and Bladder Cancer Canada; the American College of Physicians; the Joint Consensus Statement of the Renal Association and British Association of Urological Surgeons; and the National Institute for Health and Care Excellence. All guidelines reviewed recommend evaluation for AMH in the absence of potential benign aetiologies, with the evaluation including cystoscopy and upper urinary tract imaging. Existing guidelines vary in their definition of AMH (role of urine dipstick vs urine microscopy), the age threshold for recommending evaluation, and the optimal imaging method (computed tomography vs ultrasonography). Of the reviewed guidelines, none recommended the use of urine cytology or urine markers during the initial AMH evaluation. Patients should have ongoing follow-up after a negative initial AMH evaluation. Significant variation exists among current guidelines for AMH with respect to who should be evaluated and in what manner. Given the patient and health system implications of balancing appropriately focused and effective diagnostic evaluation, AMH represents a valuable future research opportunity. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  14. Chronic pancreatitis: diagnosis, classification, and new genetic developments.

    PubMed

    Etemad, B; Whitcomb, D C

    2001-02-01

    The utilization of recent advances in molecular and genomic technologies and progress in pancreatic imaging techniques provided remarkable insight into genetic, environmental, immunologic, and pathobiological factors leading to chronic pancreatitis. Translation of these advances into clinical practice demands a reassessment of current approaches to diagnosis, classification, and staging. We conclude that an adequate pancreatic biopsy must be the gold standard against which all diagnostic approaches are judged. Although computed tomography remains the initial test of choice for the diagnosis of chronic pancreatitis, the roles of endoscopic retrograde pancreatography, endoscopic ultrasonography, and magnetic resonance imaging are considered. Once chronic pancreatitis is diagnosed, proper classification becomes important. Major predisposing risk factors to chronic pancreatitis may be categorized as either (1) toxic-metabolic, (2) idiopathic, (3) genetic, (4) autoimmune, (5) recurrent and severe acute pancreatitis, or (6) obstructive (TIGAR-O system). After classification, staging of pancreatic function, injury, and fibrosis becomes the next major concern. Further research is needed to determine the clinical and natural history of chronic pancreatitis developing in the context of various risk factors. New methods are needed for early diagnosis of chronic pancreatitis, and new therapies are needed to determine whether interventions will delay or prevent the progression of the irreversible damage characterizing end-stage chronic pancreatitis.

  15. Xeroradiography and ultrasonography in the evaluation of a penile injury.

    PubMed

    Oesterling, J E; Bromberg, W D; Albertsen, P C

    1986-04-01

    A 34-year-old white man presented with severe penile cellulitis following injection of epoxy glue into the shaft of the penis. Preoperative xeroradiography and ultrasonography localized the hardened masses of glue to the left corpus cavernosum and subcutaneous tissues. Under the guidance of intraoperative ultrasonography this foreign material was removed surgically. Postoperatively, the cellulitis resolved promptly and xeroradiography demonstrated no residual fragments. Although various modalities, including computerized tomography and roentgenography, are available to detect foreign bodies in soft tissues, xeroradiography and ultrasonography are ideally suited for use in the male external genitalia.

  16. Ultrasound-Guided Elbow Procedures.

    PubMed

    Sussman, Walter I; Williams, Christopher J; Mautner, Ken

    2016-08-01

    High-resolution ultrasonography can help clinicians visualize key anatomic structures of the elbow and guide periarticular and intra-articular injections. Historically, most procedures done around the elbow have been done using landmark guidance, and few studies have reported the accuracy of ultrasonography-guided injections in the elbow region. This article reviews common musculoskeletal disorders about the elbow that can be evaluated with ultrasonography, reviews the literature on ultrasonography-guided injections of the elbow region, and describes the senior author's preferred approach for the most commonly performed elbow region injections. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Diagnostic Value of Elastography in the Diagnosis of Intermetatarsal Neuroma.

    PubMed

    Ormeci, Tugrul; Güler, Olcay; Malkoc, Melih; Keskinbora, Mert; Güngören, Fatma Zeynep; Mahirogulları, Mahir

    2016-01-01

    The objective of the present study was to characterize the ultrasound and elastographic properties of intermetatarsal neuroma (interdigital neuroma) and their contribution to diagnosis. Eighteen patients with metatarsalgia, who had presented to an orthopedic clinic from April 2013 to February 2015, were diagnosed with 25 intermetatarsal neuromas (11 unilateral [61.11%], 7 bilateral [38.89%]). These patients underwent evaluation with ultrasonography and simultaneous ultrasound strain elastography to assess the elastographic properties of the tissues in the intermetatarsal space. The intermetatarsal neuroma diagnosis was confirmed by histopathologic inspection. The lesion contours, localization, dimensions, and vascularization were evaluated before surgical excision. The elasticity and strain ratio values were compared between the neuroma and adjacent healthy intermetatarsal space. Of the 25 intermetatarsal neuromas, 1 (4%) was not detected by ultrasonography (incidence of detection of 96%). The mean neuroma width was 6.35 (range 3.7 to 13) mm in the coronal plane, and the mean elasticity and strain ratio values were 3.44 (range 1.1 to 5.1) and 9.47 (range 2.3 to 19.3), respectively. The elasticity and strain ratio values were significantly greater in the presence of an interdigital neuroma than in the adjacent healthy intermetatarsal spaces (Z = -3.964, p = .0001 and Z = -3.927, p = .0001, respectively). The diagnostic cutoff values were calculated as 2.52 for elasticity and 6.1 for the strain ratio. Four neuromas (16%) were not demarcated, and the elasticity and strain ratio values for these were lower than those for neuromas with demarcated contours but were greater than those for healthy intermetatarsal spaces (p < .006 and p < .005, respectively). Patients with clinically suspected intermetatarsal neuromas that do not show demarcation and with smaller lesions might benefit from the use of ultrasound elastography for diagnosis. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Accuracy of endoscopic ultrasonography for diagnosing ulcerative early gastric cancers

    PubMed Central

    Park, Jin-Seok; Kim, Hyungkil; Bang, Byongwook; Kwon, Kyesook; Shin, Youngwoon

    2016-01-01

    Abstract Although endoscopic ultrasonography (EUS) is the first-choice imaging modality for predicting the invasion depth of early gastric cancer (EGC), the prediction accuracy of EUS is significantly decreased when EGC is combined with ulceration. The aim of present study was to compare the accuracy of EUS and conventional endoscopy (CE) for determining the depth of EGC. In addition, the various clinic-pathologic factors affecting the diagnostic accuracy of EUS, with a particular focus on endoscopic ulcer shapes, were evaluated. We retrospectively reviewed data from 236 consecutive patients with ulcerative EGC. All patients underwent EUS for estimating tumor invasion depth, followed by either curative surgery or endoscopic treatment. The diagnostic accuracy of EUS and CE was evaluated by comparing the final histologic result of resected specimen. The correlation between accuracy of EUS and characteristics of EGC (tumor size, histology, location in stomach, tumor invasion depth, and endoscopic ulcer shapes) was analyzed. Endoscopic ulcer shapes were classified into 3 groups: definite ulcer, superficial ulcer, and ill-defined ulcer. The overall accuracy of EUS and CE for predicting the invasion depth in ulcerative EGC was 68.6% and 55.5%, respectively. Of the 236 patients, 36 patients were classified as definite ulcers, 98 were superficial ulcers, and 102 were ill-defined ulcers, In univariate analysis, EUS accuracy was associated with invasion depth (P = 0.023), tumor size (P = 0.034), and endoscopic ulcer shapes (P = 0.001). In multivariate analysis, there is a significant association between superficial ulcer in CE and EUS accuracy (odds ratio: 2.977; 95% confidence interval: 1.255–7.064; P = 0.013). The accuracy of EUS for determining tumor invasion depth in ulcerative EGC was superior to that of CE. In addition, ulcer shape was an important factor that affected EUS accuracy. PMID:27472672

  19. [Hyperthyroidism and carcinoma of the thyroid gland].

    PubMed

    Ardito, G; Mantovani, M; Vincenzoni, C; Guidi, M L; Corsello, S; Rabitti, C; Fadda, G; Di Giovanni, V

    1997-01-01

    The incidence of thyroid carcinoma in hyperthyroidism varies considerably from as low as 0.3% to as high as 16.6% with a higher rate in toxic nodular goiters. Occult thyroid carcinoma (< 1.5 cm or microscopic foci) is the rule and only a few tumors are suspected preoperatively with ultrasonography or fine needle aspiration or 131 I scan. In 408 patients who underwent surgery for hyperthyroidism in our Surgery Department from January 1967 through December 1994 the incidence of thyroid carcinoma was 5.6% (23 cases). In detail, a neoplasm occurred in 5 cases of Graves' disease (specific incidence: 3.8%), in 13 cases of toxic nodular goiter (12.5%) and in 5 cases of hyperfunctioning adenomas (2.8%). 19 cancers were papillary (12 in toxic nodular goiter, 3 in Graves' disease, 4 in hyperfunctioning adenomas), three were follicular (1 in Graves' disease, 1 in toxic nodular goiter, 1 in hyperfunctioning adenomas) and 1 medullary in Graves' disease. A papillary carcinoma was diagnosed preoperatively on fine needle aspiration with ultrasonography in only two patients with Graves' disease and confirmed by postoperative histological examination on permanent section. We do not believe in the frozen-section examination intraoperatively because it's not diagnostical for follicular lesions and evaluates rarely capsular invasion. Twenty patients received total thyroidectomy and four of them also lymphoadenectomy. Three patients received emithyroidectomy: in two cases for occult papillary carcinoma and in the last case for local cancer invasion (T4N0M0). Twenty patients are alive and with no evidence of cancer recurrence. Mean follow-up is 59.6 months. Our retrospective study shows a progressive increase of the incidence of coexisting thyroid malignancy and hyperthyroidism especially in toxic nodular goiter, probably related to extended surgical indications. Our findings do confirm that, even in the presence of hyperthyroidism, all thyroid nodules require careful diagnostics for exclusion of malignancy.

  20. Incremental Value (Bayesian Framework) of Thoracic Ultrasonography over Thoracic Auscultation for Diagnosis of Bronchopneumonia in Preweaned Dairy Calves.

    PubMed

    Buczinski, S; Ménard, J; Timsit, E

    2016-07-01

    Thoracic ultrasonography (TUS) is a specific and relatively sensitive method to diagnose bronchopneumonia (BP) in dairy calves. Unfortunately, as it requires specific training and equipment, veterinarians typically base their diagnosis on thoracic auscultation (AUSC), which is rapid and easy to perform. We hypothesized that the use of TUS, in addition to AUSC, can significantly increase accuracy of BP diagnosis. Therefore, the objectives were to (i) determine the incremental value of TUS over AUSC for diagnosis of BP in preweaned dairy calves and (ii) assess diagnostic accuracy of AUSC. Two hundred and nine dairy calves (<1 month of age) were enrolled in this cross-sectional study. Prospective cross-sectional study. All calves from a veal calves unit were examined (independent operators) using the Wisconsin Calf Respiratory Scoring Criteria (CRSC), AUSC, and TUS. A Bayesian latent class approach was used to estimate the incremental value of AUSC over TUS (integrated discrimination improvement [IDI]) and the diagnostic accuracy of AUSC. Abnormal CRSC, AUSC, and TUS were recorded in 3.3, 53.1, and 23.9% of calves, respectively. AUSC was sensitive (72.9%; 95% Bayesian credible interval [BCI]: 50.1-96.4%), but not specific (53.3%; 95% BCI: 43.3-64.0%) to diagnose BP. Compared to AUSC, TUS was more specific (92.9%; 95% BCI: 86.5-97.1%), but had similar sensitivity (76.5%; 95% BCI: 60.2-88.8%). The incremental value of TUS over AUSC was high (IDI = 43.7%; 5% BCI: 22.0-63.0%) significantly improving proportions of sick and healthy calves appropriately classified. The use of TUS over AUSC significantly improved accuracy of BP diagnosis in dairy calves. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  1. Musculoskeletal Ultrasonography in CRPS: Assessment of Muscles Before and After Motor Function Recovery with Dry Needling as the Sole Treatment.

    PubMed

    Vas, Lakshmi Champak; Pai, Renuka; Pattnaik, Manorama

    2016-01-01

    Motor impairment is an important criterion in the Clinical Diagnostic Criteria (CDC) of Complex Regional Pain Syndrome type-1 (CRPS-1) as defined by International Association for Study of Pain (IASP). To describe the changes in musculoskeletal ultrasonography (MSKUSG) in CRPS-1 before and after treatment with ultrasound-guided dry needling (USGDN) in retrospective data from 44 patients. Patients irrespective of age, gender, or cause of CRPS were included in this retrospective data analysis; the Budapest criteria for the diagnosis of CRPS were stringently adhered to. The analysis was done at Ashirvad Institute for Pain Management and Research with the database of CRPS patients who were treated between December 2005 and December 2014. The CDC, range of motion at upper extremity joints, dynamometry, Disability of arm, shoulder and hand score (DASH) and ultrasonography were documented on days one, 15, and 45. MSKUSG demonstrated loss of myoarchitecture and reduced bulk. All 44 patients received USGDN as the sole intervention with medications and physiotherapy. MSKUSG at 15 and 45 days after starting USGDN showed a return of normalcy to the myoarchitecture and muscle bulk increase that coincided with the disappearance of CDC and a progressive and predictable improvement of the DASH scores in all the 44 patients. The analysis focuses on only 2 parameters: the musculoskeletal changes of the forearm flexors and extensors on ultrasound guidance and the efficacy of the dry needling treatment. It is not a comparative study with another accepted form of treatment or intervention. We have not looked into the age and gender predilection of the condition owing to the small sample size of the study. Analysis of long term maintenance of relief and rehabilitation of the disability were limited to one year. Myofascial pathology of co-contraction appears to cause CDC of CRPS and probable ischemic loss of myoarchitecture. Relief of co-contraction with USGDN allowed resolution of tenosynovitis causing the CDC and return of normal myoarchitecture.

  2. [Technical specification for clinical application of critical ultrasonography].

    PubMed

    Yin, M G; Wang, X T; Liu, D W; Chao, Y G; Guan, X D; Kang, Y; Yan, J; Ma, X C; Tang, Y Q; Hu, Z J; Yu, K J; Chen, D C; Ai, Y H; Zhang, L N; Zhang, H M; Wu, J; Liu, L X; Zhu, R; He, W; Zhang, Q; Ding, X; Li, L; Li, Y; Liu, H T; Zeng, Q B; Si, X; Chen, H; Zhang, J W; Xu, Q H; Chen, W J; Chen, X K; Huang, D Z; Cai, S H; Shang, X L; Guan, J; Du, J; Zhao, L; Wang, M J; Cui, S; Wang, X M; Zhou, R; Zeng, X Y; Wang, Y P; Lyu, L W; Zhu, W H; Zhu, Y; Duan, J; Yang, J; Yang, H

    2018-06-01

    Critical ultrasonography(CUS) is different from the traditional diagnostic ultrasound, the examiner and interpreter of the image are critical care medicine physicians. The core content of CUS is to evaluate the pathophysiological changes of organs and systems and etiology changes. With the idea of critical care medicine as the soul, it can integrate the above information and clinical information, bedside real-time diagnosis and titration treatment, and evaluate the therapeutic effect so as to improve the outcome. CUS is a traditional technique which is applied as a new application method. The consensus of experts on critical ultrasonography in China released in 2016 put forward consensus suggestions on the concept, implementation and application of CUS. It should be further emphasized that the accurate and objective assessment and implementation of CUS requires the standardization of ultrasound image acquisition and the need to establish a CUS procedure. At the same time, the standardized training for CUS accepted by critical care medicine physicians requires the application of technical specifications, and the establishment of technical specifications is the basis for the quality control and continuous improvement of CUS. Chinese Critical Ultrasound Study Group and Critical Hemodynamic Therapy Collabration Group, based on the rich experience of clinical practice in critical care and research, combined with the essence of CUS, to learn the traditional ultrasonic essence, established the clinical application technical specifications of CUS, including in five parts: basic view and relevant indicators to obtain in CUS; basic norms for viscera organ assessment and special assessment; standardized processes and systematic inspection programs; examples of CUS applications; CUS training and the application of qualification certification. The establishment of applied technology standard is helpful for standardized training and clinical correct implementation. It is helpful for clinical evaluation and correct guidance treatment, and is also helpful for quality control and continuous improvement of CUS application.

  3. Comparison of radiography and ultrasonography for the diagnosis of osteochondritis dissecans in the equine femoropatellar joint.

    PubMed

    Bourzac, C; Alexander, K; Rossier, Y; Laverty, S

    2009-09-01

    Osteochondritis dissecans (OCD) lesions of the femoropatellar (FP) joint are diagnosed routinely by radiography, but lesions located in the trochlear groove or without accompanying subchondral bone changes can be difficult to visualise. Ultrasonography allows evaluation of articular cartilage and subchondral bone in the FPjoint. To document the radiographic and ultrasonographic appearance of OCD lesions in the equine FP joint, grade ultrasonographic lesions and compare their accuracy in the diagnosis of these lesions. The medical records of all horses diagnosed with FP OCD between 1995 and 2006 were assessed. Inclusion criteria included availability of both radiographic and ultrasonographic images. Lesion characteristics were evaluated in each trochlear ridge and trochlear groove. For assessment of the accuracy (sensitivity and specificity) of both imaging techniques in the diagnosis of OCD, only cases with an arthroscopic or necropsy examination were studied. Twenty-one horses were included. OCD lesions were diagnosed by radiography (30/32 joints) and ultrasound (32/32 joints). The lateral trochlear ridge (LTR, 91%) and the medial trochlear ridge (MTR, 17%) were involved on radiography. The localisation on ultrasound examination was similar (97% LTR, 25% MTR). All but one lesion seen on radiography were also detected with ultrasound; 2 LTR and 3 MTR lesions, not seen on radiography were diagnosed by ultrasound and confirmed at arthroscopy or necropsy. The specificity was 100% regardless of the site and imaging procedure except for the distal third of the MTR (94% for ultrasound). The sensitivity varied, depending on lesion site. Ultrasonography is a valuable diagnostic tool to diagnose OCD lesions in the FP joint and more sensitive than radiography for lesions affecting the MTR of the distal femur. Ultrasound should be considered as a useful adjunct to radiography for diagnosing equine FP OCD, especially in cases of high clinical suspicion but equivocal radiographic findings. Images can be generated immediately when digital radiography is not available, permitting an immediate on-site diagnosis.

  4. Diagnostic characteristics and metabolic risk factors of cases with polycystic ovary syndrome during adolescence.

    PubMed

    Sıklar, Zeynep; Berberoğlu, Merih; Çamtosun, Emine; Kocaay, Pınar

    2015-04-01

    Polycystic ovary syndrome (PCOS) is a disorder without definite consensus on its diagnosis and management during adolescence. According to Amsterdam-2012 consensus, as physiological characteristics of adolescence may overlap with PCOS signs, it has been indicated that all Rotterdam criteria should be met. In this present study, characteristics of adolescents with different phenotypes who were diagnosed with PCOS were evaluated; and presence of differences for metabolic risk factors between phenotypes were investigated. The study was performed on adolescent females. According to phenotypic application models, individuals with all Rotterdam diagnostic criteria [hyperandrogenism (HA), polycystic ovarian morphology (PCOM), and chronic anovulation (CA) on the ultrasonography] were in Group 1 (n = 26); with HA and CA were in Group 2 (n = 10); with HA and PCOM were in Group 3 (n = 7); and with CA and PCOM were in Group 4 (n = 10). The most common application complaint (87%) among 53 cases enrolled in the study was menstrual irregularities, and 57% of cases were not obese. When PCOS was evaluated according to phenotypes, it was realized that cases that meet all 3 diagnostic Rotterdam criteria according to the current recommendation in adolescents. (Group 1) was the most common phenotype. Hyperandrogenism was associated with more metabolic abnormalities. The close monitoring of adolescents, who have 2 diagnostic criteria is advisable among PCOS phenotypes. Potentially Groups 2 and 3 which have hyperandrogenism, in particular should warrant closer follow-up although they do not meet current diagnostic criteria for adolescents. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  5. [Fever of unknown origin (febris continua e causa ignota)].

    PubMed

    Hansen, T H; Seidenfaden-Lassen, M

    1992-02-10

    Fever can be recognized as a higher set-point of the normal temperature regulation which is controlled by the center in the anterior part of hypothalamus. The change in this set-point is induced by interleukin-1 (IL-1) which is the common mediator of exogenic and endogenic pyrogenic factors. IL-1 is believed to act through an induction of a prostaglandin E cascade. The normal diurnal variation in temperature can often be recognized in infectious diseases but not always in non-infectious conditions. Four different fever curves can be defined but are without differential diagnostic importance, however, septic fever curves are more likely to occur in bacteremic patients. Comparison of the most important investigations about PUO since 1960 shows that the follow-up investigations revealed a high percentage of undiagnosed cases and that the mortality due to conditions related to PUO was 6-8%. Among the other investigations, a total of 83% were diagnosed: 23% had cancer, 33% had infections, 11% had collagenic diseases, 17% had other causes and 16% were undiagnosed. To establish the diagnosis in cases of PUO, liver biopsy can be of diagnostic value especially in patients with hepatomegaly. Abdominal CT-scan, ultrasonography and Gallium 67 scintigraphy are equal in sensitivity and specificity and can supplement each other with diagnostic information. Leucocyte scintigraphy can detect local inflammatory processes. Laparotomy or laparoscopy have high diagnostic values and can be considered in patients with signs of involvement of abdominal organs if no diagnosis has been established after noninvasive investigations. Lymphography gives only limited diagnostic information in cases of PUO.

  6. Imaging techniques used in the diagnostic workup of acute venous thromboembolic disease.

    PubMed

    Tilve-Gómez, A; Rodríguez-Fernández, P; Trillo-Fandiño, L; Plasencia-Martínez, J M

    Early diagnosis is one of the most important factors affecting the prognosis of pulmonary embolism (PE); however, the clinical presentation of PE is often very unspecific and it can simulate other diseases. For these reasons, imaging tests, especially computed tomography angiography (CTA) of the pulmonary arteries, have become the keystone in the diagnostic workup of PE. The wide availability and high diagnostic performance of pulmonary CTA has led to an increase in the number of examinations done and a consequent increase in the population's exposure to radiation and iodinated contrast material. Thus, other techniques such as scintigraphy and venous ultrasonography of the lower limbs, although less accurate, continue to be used in certain circumstances, and optimized protocols have been developed for CTA to reduce the dose of radiation (by decreasing the kilovoltage) and the dose of contrast agents. We describe the technical characteristics and interpretation of the findings for each imaging technique used to diagnose PE and discuss their advantages and limitations; this knowledge will help the best technique to be chosen for each case. Finally, we comment on some data about the increased use of CTA, its clinical repercussions, its "overuse", and doubts about its cost-effectiveness. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Tuberculosis of hip: A current concept review

    PubMed Central

    Saraf, Shyam Kumar; Tuli, Surendra Mohan

    2015-01-01

    Tuberculosis (TB) of the hip is second to spine only hence a good number of cases are visiting the medical facilities every year. Many present in the advanced stage of the disease due to delayed diagnosis. In early stages of TB of hip, there is a diagnostic dilemma when plain X-rays are negative. In the present time, diagnostic modalities have improved from the days when diagnosis was based essentially on clinicoradiological presentation alone. By the time definite radiological changes appear on plain X-ray, the disease has moderately advanced. The modern diagnostic facilities like ultrasonography (USG) or magnetic resonance imaging of the hip joint, USG guided aspiration of synovial fluid and obtaining the material for polymerase chain reaction and tissue diagnosis must be utilized. In the treatment, current emphasis is more on mobility with stability at hip. Joint debridement, skeletal traction, and mobilization exercises may give more satisfying results as compared to the immobilization by hip spica. Adults with advanced arthritis and healed infection should be informed and discussed the various treatment modalities including the joint replacement. More and more surgeons are taking up the challenge of putting the total hip replacement in the active stage of the disease. Until the long term results in active disease are well established, we recommend it for the healed disease only in selected cases. PMID:25593352

  8. Tuberculosis of hip: A current concept review.

    PubMed

    Saraf, Shyam Kumar; Tuli, Surendra Mohan

    2015-01-01

    Tuberculosis (TB) of the hip is second to spine only hence a good number of cases are visiting the medical facilities every year. Many present in the advanced stage of the disease due to delayed diagnosis. In early stages of TB of hip, there is a diagnostic dilemma when plain X-rays are negative. In the present time, diagnostic modalities have improved from the days when diagnosis was based essentially on clinicoradiological presentation alone. By the time definite radiological changes appear on plain X-ray, the disease has moderately advanced. The modern diagnostic facilities like ultrasonography (USG) or magnetic resonance imaging of the hip joint, USG guided aspiration of synovial fluid and obtaining the material for polymerase chain reaction and tissue diagnosis must be utilized. In the treatment, current emphasis is more on mobility with stability at hip. Joint debridement, skeletal traction, and mobilization exercises may give more satisfying results as compared to the immobilization by hip spica. Adults with advanced arthritis and healed infection should be informed and discussed the various treatment modalities including the joint replacement. More and more surgeons are taking up the challenge of putting the total hip replacement in the active stage of the disease. Until the long term results in active disease are well established, we recommend it for the healed disease only in selected cases.

  9. The Efficacy of Thoracic Ultrasonography in Postoperative Newborn Patients after Cardiac Surgery

    PubMed Central

    Ozturk, Erkut; Tanidir, Ibrahim Cansaran; Yildiz, Okan; Ergul, Yakup; Guzeltas, Alper

    2017-01-01

    Objective In this study, the efficacy of thoracic ultrasonography during echocardiography was evaluated in newborns. Methods Sixty newborns who had undergone pediatric cardiac surgery were successively evaluated between March 1, 2015, and September 1, 2015. Patients were evaluated for effusion, pulmonary atelectasis, and pneumothorax by ultrasonography, and results were compared with X-ray findings. Results Sixty percent (n=42) of the cases were male, the median age was 14 days (2-30 days), and the median body weight was 3.3 kg (2.8-4.5 kg). The median RACHS-1 score was 4 (2-6). Atelectasis was demonstrated in 66% (n=40) of the cases. Five of them were determined solely by X-ray, 10 of them only by ultrasonography, and 25 of them by both ultrasonography and X-ray. Pneumothorax was determined in 20% (n=12) of the cases. Excluding one case determined by both methods, all of the 11 cases were diagnosed by X-ray. Pleural effusion was diagnosed in 26% (n=16) of the cases. Four of the cases were demonstrated solely by ultrasonography, three of them solely by X-ray, and nine of the cases by both methods. Pericardial effusion was demonstrated in 10% (n=6) of the cases. Except for one of the cases determined by both methods, five of the cases were diagnosed by ultrasonography. There was a moderate correlation when all pathologies evaluated together (k=0.51). Conclusion Thoracic ultrasonography might be a beneficial non-invasive method to evaluate postoperative respiratory problems in newborns who had congenital cardiac surgery. PMID:28977200

  10. In-flight thoracic ultrasound detection of pneumothorax in combat.

    PubMed

    Madill, Justin J

    2010-08-01

    Ultrasonography is the only portable imaging modality available in the helicopter medical evacuation environment where physical examination is limited, auscultation is impossible, long transport times may occur, and altitude variations are frequent. Although the use of ultrasonography by aviation medical personnel has been documented, minimal literature exists on the contribution of in-flight ultrasonography to patient management. This case demonstrates an indication for the use of in-flight ultrasonography. It shows how it can affect in-flight management and direct lifesaving intervention. A patient with blast injury developed hemodynamic instability of unclear etiology during transport in the combat aviation environment. To our knowledge, this is the first reported case where in-flight thoracic ultrasonography augmented physical examination and diagnosed an untreated pneumothorax when auscultation was impossible. It directed the decision to perform in-flight procedural intervention with tube thoracostomy. This rapidly improved the patient's hemodynamic stability in a remote and hostile setting. In-flight thoracic ultrasonography is a portable imaging tool that can be used by aviation medical personnel to detect pneumothorax in environments where physical examination is limited and auscultation is impossible. Published by Elsevier Inc.

  11. Point shear wave elastography of the pancreas in patients with cystic fibrosis: a comparison with healthy controls.

    PubMed

    Pfahler, Matthias Hermann Christian; Kratzer, Wolfgang; Leichsenring, Michael; Graeter, Tilmann; Schmidt, Stefan Andreas; Wendlik, Inka; Lormes, Elisabeth; Schmidberger, Julian; Fabricius, Dorit

    2018-02-19

    Manifestations of cystic fibrosis in the pancreas are gaining in clinical importance as patients live longer. Conventional ultrasonography and point shear wave elastography (pSWE) imaging are non-invasive and readily available diagnostic methods that are easy to perform. The aim of this study was to perform conventional ultrasonography and obtain pSWE values in the pancreases of patients with cystic fibrosis and to compare the findings with those of healthy controls. 27 patients with cystic fibrosis (13 women/14 men; mean age 27.7 ± 13.7 years; range 9-58 years) and 60 healthy control subjects (30 women/30 men; mean age 30.3 ± 10.0 years; range 22-55 years) underwent examinations of the pancreas with conventional ultrasound and pSWE imaging. Patients with cystic fibrosis have an echogenic pancreatic parenchyma. We found cystic lesions of the pancreas in six patients. pSWE imaging of the pancreatic parenchyma gave significantly lower shear wave velocities in patients with cystic fibrosis than in the control group (1.01 m/s vs 1.30 m/s; p < 0.001). Using pSWE imaging in vivo, we have shown that the pancreas is considerably softer in patients with cystic fibrosis than in a healthy control population.

  12. Mondor's disease of the breast. A retrospective review.

    PubMed

    Salemis, Nikolaos S; Merkouris, Stamatios; Kimpouri, Konstantina

    2011-01-01

    Mondor's disease is a rare benign clinical entity characterized by thrombophlebitis of the superficial veins of the anterolateral thoraco-abdominal wall. Although several predisposing factors have been reported, the exact pathogenesis remains unclear. We retrospectively reviewed the medical records of all patients older than 14 years who were diagnosed with Mondor's disease of the breast at the Breast Cancer Surgery Unit of Army General Hospital over a 3-year period. Five cases of Mondor's disease were identified among 5717 breast examinations performed during the study period. In 4 patients the disease was considered to be idiopathic. Ultrasonography established the diagnosis in all patients but mammography was inconclusive in two cases due to the presence of dense breast tissue. Four patients received symptomatic treatment. All patients had complete clinical resolution within 2-8 weeks of presentation, and they are well without any evidence of recurrence for 3 to 32 months later. No cases were associated with breast cancer. Mondor's disease of the breast is a rare benign self-limiting clinical entity. Ultrasonography is the diagnostic modality of choice but mammography may be inconclusive in the presence of dense breast tissue. Awareness of this rare entity is mandatory to prevent an unnecessary biopsy whereas the patients should be reassured of the benign nature of this disorder. Thorough evaluation is however necessary to rule out an underlying breast cancer or another systemic disease.

  13. Transperineal ultrasonography: First level exam in IBD patients with perianal disease.

    PubMed

    Terracciano, Fulvia; Scalisi, Giuseppe; Bossa, Fabrizio; Scimeca, Daniela; Biscaglia, Giuseppe; Mangiacotti, Michele; Valvano, Maria Rosa; Perri, Francesco; Simeone, Anna; Andriulli, Angelo

    2016-08-01

    A pelvic magnetic resonance imaging (MRI) represents the front-line method for evaluating perianal disease in patients with inflammatory bowel disease (IBD). Recently, transperineal ultrasonography (TPUS) has been proposed as a simple, safe, time-sparing and useful diagnostic technique to assess different pathological conditions of the pelvic floor. The aim of this prospective single centre study was to evaluate the accuracy of TPUS versus MRI for the detection and classification of perineal disease in IBD patients. From November 2013 to November 2014, 28 IBD patients underwent either TPUS or MRI. Fistulae and abscesses were classified according to Parks' and AGA's classification methods. A concordance was assessed by k statistics. Overall, 33 fistulae and 8 abscesses were recognized by TPUS (30 and 7 by MRI, respectively). The agreement between TPUS and MRI was 75% according to Parks' classification (k=0.67) and 86% according to AGA classification (k=0.83), while it was 36% (k=0.34) for classifying abscesses. TPUS proved to be as accurate as MRI for detecting superficial and small abscesses and for classifying perianal disease. Both examinations may be performed at the initial presentation of the patient, but TPUS is a cheaper, time-sparing procedure. The optimal use of TPUS might be in follow-up patients. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  14. A comparison between transabdominal ultrasonographic and cystourethroscopy findings in adult Sudanese patients presenting with haematuria.

    PubMed

    Ahmed, Feras O; Hamdan, Hamdan Z; Abdelgalil, Hani B; Sharfi, Abdulrauf A

    2015-02-01

    Gross and microscopic haematuria both are a common cause of referral to urology clinics. It has a wide spectrum of differential. In many occasions, it is a presentation of underlining serious urological problems. Evaluation of gross and significant microscopic haematuria is of paramount importance. This study was conducted to assess and compare the findings and diagnostic competency of transabdominal ultrasonography (US) versus cystourethroscopy in patients with haematuria of lower urinary tract origin. Prospective hospital-based study done at Ibn Sina Specialized and Omdurman Military Hospitals from June 2012 to March 2013. The study included 109 patients. Structured questionnaires were used to gather data from patients. All patients were evaluated by transabdominal US before cystourethroscopy examination. One hundred and nine patients were studied. Patients' mean (SD) age was 57.9 (18.8) years. Fifty-four patients (49.5 %) presented with macroscopic haematuria, while 55 patients presented with microscopic haematuria. The sensitivity and specificity of the US in detecting prostate enlargement, vesical stones, bladder wall tumour, cystitis and schistosomiasis were [(84, 80 %); (82.6, 97.7 %); (64.7, 92.1 %); (15.3, 96.8 %); and (15.3, 98.9 %)], respectively, as compared to cystoscopic finding as the gold standard. Ultrasonography is accepted only as a first-line imaging tool for evaluation of haematuria in poor settings, but cannot replace or became as good as cystoscopy, which remains the gold standard.

  15. Prenatal diagnosis of Joubert syndrome

    PubMed Central

    Zhu, Lingling; Xie, Limei

    2017-01-01

    Abstract Introduction: Joubert syndrome (JS) is a rare autosomal recessive inherited disease belonging to ciliopathy with the causative mutation of genes. Except for X-linked inheritance, the high recurrence rate of a family is about 25%. After birth, it may cause a series of neurological symptoms, even with retina, kidney, liver, and other organ abnormalities, which is defined as Joubert syndrome and related disorders (JSRD). Molecular genetics research contributes to disease prediction and genetic counseling. Prenatal diagnosis is rare. Magnetic resonance imaging (MRI) is usually the first-choice diagnostic modality with typical brain images characterized by the molar tooth sign. We describe a case of JS prenatally and Dandy-Walker malformation for the differential diagnosis based on ultrasonograms. We also review the etiology, imaging features, clinical symptoms, and diagnosis of JSRD. Case presentation: A 22-year-old woman was pregnant at 27 1/7 weeks’ gestation with fetal cerebellar vermis hypoplasia. Fetal ultrasonography and MRI confirmed a diagnosis of JS at our center. The couple finally opted to terminate the fetus, which had a normal appearance and growth parameters. The couple also had an AHI1 gene mutation on chromosome 6. Conclusions: Currently, a diagnosis of JS is commonly made after birth. Fewer cases of prenatal diagnosis by ultrasonography have been made, and they are more liable to be misdirected because of some nonspecial features that also manifest in Dandy-Walker malformation, cranio-cerebello-cardiac syndrome, and so on. PMID:29390414

  16. Neck ultrasonography for detection of non-recurrent laryngeal nerve

    PubMed Central

    Citton, Marilisa; Viel, Giovanni

    2016-01-01

    Background Non-recurrent laryngeal nerve (NRLN) is a rare anatomical variant (0.3–6%) that is associated with some arterial abnormalities (absence of the brachiocephalic trunk and presence of a right aberrant subclavian lusorian artery). The availability of a preoperative diagnosis of NRLN may reduce the risk of nerve injuries. Preoperative ultrasonography (US) has been suggested as a reliable diagnostic tool to detect the arterial abnormalities associated with NRLN, but the literature is relatively scarce. This paper was aimed to review the literature, in order to offer an up to-date on this technique and its results. Methods A web search, focusing on humans, was performed by PubMed database, including papers published up to August 2016, using the key words “ultrasonography” AND “non-recurrent laryngeal nerve” or “nonrecurrent laryngeal nerve”. Results Eight papers, including 3,740 patients who underwent neck US for the detection of NRLN were selected. Only five studies focused on the preoperative use of US. The incidence of NRLN varied between 0.4% and 1.94%. The sensitivity and specificity varied between 99–100% and 41–100%, respectively. Conclusions US is a simple, non-invasive and cost-effective method to detect NRLN, also if its accuracy is not absolute. It may be used preoperatively and to prevent the intraoperative nerve damage, since the risk of NRLN palsies is significantly reduced when a preoperative diagnosis is available. PMID:28149804

  17. Ultrasound imaging of the nose in septorhinoplasty patients.

    PubMed

    Stenner, Markus; Rudack, Claudia

    2015-10-01

    Detailed preoperative planning based on available clinical information is an essential component of determining septorhinoplasty outcome. In addition to rhinoscopy and airway measurements, preoperative photographs are the only image modalities that are regularly used in septorhinoplasty patients and contribute to the preoperative planning of the surgery. The aim of this study was to evaluate the use of high-resolution ultrasonography in septorhinoplasty patients before surgery and during follow-up. We examined 35 patients before and after open septorhinoplasty using 12- and 15-MHz B-mode, linear array transducer ultrasound in noncontact mode. The patients presented with a variety of different functional and aesthetic problems, and all underwent septorhinoplasty for septal modification, and tip and dorsum refinement. The mean follow-up time for ultrasound after surgery was 4.5 weeks. Soft tissue, cartilaginous, and bony structures of the nose could be well-visualised. In the untreated nose, functional and aesthetic characteristics as well as preoperative anatomy relevant for the planning of the surgery could be documented. Surgical modifications of the treated nose postoperatively, that is, osteotomies, inserted spreader grafts, diced cartilage in fascia, and tip sutures could be visualized and followed. Ultrasonography of the nose with a high-frequency transducer may be a helpful tool during preoperative planning and postoperative follow-up in septorhinoplasty patients and might be a reasonable completion to the common photographic and functional diagnostic.

  18. High-Resolution Ultrasonic Imaging of Dento-Periodontal Tissues Using a Multi-Element Phased Array System.

    PubMed

    Nguyen, Kim-Cuong T; Le, Lawrence H; Kaipatur, Neelambar R; Zheng, Rui; Lou, Edmond H; Major, Paul W

    2016-10-01

    Intraoral ultrasonography uses high-frequency mechanical waves to study dento-periodontium. Besides the advantages of portability and cost-effectiveness, ultrasound technique has no ionizing radiation. Previous studies employed a single transducer or an array of transducer elements, and focused on enamel thickness and distance measurement. This study used a phased array system with a 128-element array transducer to image dento-periodontal tissues. We studied two porcine lower incisors from a 6-month-old piglet using 20-MHz ultrasound. The high-resolution ultrasonographs clearly showed the cross-sectional morphological images of the hard and soft tissues. The investigation used an integration of waveform analysis, travel-time calculation, and wavefield simulation to reveal the nature of the ultrasound data, which makes the study novel. With the assistance of time-distance radio-frequency records, we robustly justified the enamel-dentin interface, dentin-pulp interface, and the cemento-enamel junction. The alveolar crest level, the location of cemento-enamel junction, and the thickness of alveolar crest were measured from the images and compared favorably with those from the cone beam computed tomography with less than 10% difference. This preliminary and fundamental study has reinforced the conclusions from previous studies, that ultrasonography has great potential to become a non-invasive diagnostic imaging tool for quantitative assessment of periodontal structures and better delivery of oral care.

  19. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    PubMed Central

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  20. Evaluation of joint effusion in rabbits by color Doppler, power Doppler, and contrast-enhanced power Doppler ultrasonography.

    PubMed

    Lim, Gye-Yeon; Im, Soo Ah; Jung, Won Sang; Lee, Jae Mun; Lee, Ah Won

    2005-09-01

    The aim of this prospective study was to evaluate the diagnostic value of power Doppler ultrasonography (PDUS) and contrast-enhanced PDUS (CEPDUS) in the depiction and characterization of experimentally induced arthritis in the rabbit. Thirty rabbits were divided into three groups consisting of one control group (saline injection group) and two experimental groups: a suppurative arthritis group and a chemically induced synovitis group. The same amount (1 ml) of each agent was directly injected into the right hip joint. Serial color Doppler ultrasound (CDUS), PDUS, and CEPDUS images were obtained before and after injection. We observed that all of the infected knees in the suppurative arthritis group with Staphylococcus aureus demonstrated an increased signal on PDUS after inoculation. A minimal power Doppler signal was presented in the chemically induced synovitis group with talc injection, but none of the control knees demonstrated any increased signals. CEPDUS was the most sensitive imaging modality for evaluating the increase of blood flows in suppurative arthritis and was subsequently followed by PDUS and CDUS. The increased signals obtained with PDUS represent increased local blood flows; therefore, this technique can be used for evaluating the degree of inflammation. Furthermore, using the contrast agent enhances the sensitivity of PDUS, and it can even be useful for differentiating borderline cases. Copyright 2005 Wiley Periodicals, Inc

  1. Hot biopsy forceps vs. endoscopic ultrasonography in determining the depth of gastric epithelial neoplasia: a simple novel method to decide whether or not to perform endoscopic submucosal dissection.

    PubMed

    Huikai, Li; Enqiang, Linghu

    2013-01-01

    It is of vital importance to determine the depth of lesions to be treated by endoscopic submucosal dissection. This study aimed to compare the accuracy of using hot biopsy forceps method with endoscopic ultrasonography for determination of the depth of gastric epithelial neoplasia. Hot biopsy forceps method and/or endoscopic ultrasonography were used to determine the depth of lesions in 27 patients. With hot biopsy forceps method, we assumed a lesion completely lifted up by a hot biopsy forceps to be confined to the mucosal layer, and one partly lifted up to be located beyond the mucosal layer. The accuracy of hot biopsy forceps method and endoscopic ultrasonography in determining the depth of lesions were compared. Of the 27 patients, 25 underwent endoscopic submucosal dissection and 2 underwent surgery. The total accuracy of hot biopsy forceps method in determining the depth of lesions was 92.6% and that of endoscopic ultrasonography was 81.8%. Overestimation of hot biopsy forceps method and endoscopic ultrasonography were 3.7% vs. 13.6%, respectively. The sensitivity and the specificity of hot biopsy forceps method were 95.5% and 80.0% and those of EUS were 83.3% and 75.0%. Hot biopsy forceps method has a trend towards higher accuracy and lower overestimation than endoscopic ultrasonography.

  2. Strategies to diagnose ovarian cancer: new evidence from phase 3 of the multicentre international IOTA study.

    PubMed

    Testa, A; Kaijser, J; Wynants, L; Fischerova, D; Van Holsbeke, C; Franchi, D; Savelli, L; Epstein, E; Czekierdowski, A; Guerriero, S; Fruscio, R; Leone, F P G; Vergote, I; Bourne, T; Valentin, L; Van Calster, B; Timmerman, D

    2014-08-12

    To compare different ultrasound-based international ovarian tumour analysis (IOTA) strategies and risk of malignancy index (RMI) for ovarian cancer diagnosis using a meta-analysis approach of centre-specific data from IOTA3. This prospective multicentre diagnostic accuracy study included 2403 patients with 1423 benign and 980 malignant adnexal masses from 2009 until 2012. All patients underwent standardised transvaginal ultrasonography. Test performance of RMI, subjective assessment (SA) of ultrasound findings, two IOTA risk models (LR1 and LR2), and strategies involving combinations of IOTA simple rules (SRs), simple descriptors (SDs) and LR2 with and without SA was estimated using a meta-analysis approach. Reference standard was histology after surgery. The areas under the receiver operator characteristic curves of LR1, LR2, SA and RMI were 0.930 (0.917-0.942), 0.918 (0.905-0.930), 0.914 (0.886-0.936) and 0.875 (0.853-0.894). Diagnostic one-step and two-step strategies using LR1, LR2, SR and SD achieved summary estimates for sensitivity 90-96%, specificity 74-79% and diagnostic odds ratio (DOR) 32.8-50.5. Adding SA when IOTA methods yielded equivocal results improved performance (DOR 57.6-75.7). Risk of Malignancy Index had sensitivity 67%, specificity 91% and DOR 17.5. This study shows all IOTA strategies had excellent diagnostic performance in comparison with RMI. The IOTA strategy chosen may be determined by clinical preference.

  3. Testicular calculus: A rare case.

    PubMed

    Sen, Volkan; Bozkurt, Ozan; Demır, Omer; Tuna, Burcin; Yorukoglu, Kutsal; Esen, Adil

    2015-01-01

    Testicular calculus is an extremely rare case with unknown etiology and pathogenesis. To our knowledge, here we report the third case of testicular calculus. A 31-year-old man was admitted to our clinic with painful solid mass in left testis. After diagnostic work-up for a possible testicular tumour, he underwent inguinal orchiectomy and histopathologic examination showed a testicular calculus. Case hypothesis: Solid testicular lesions in young adults generally correspond to testicular cancer. Differential diagnosis should be done carefully. Future implications: In young adults with painful and solid testicular mass with hyperechogenic appearance on scrotal ultrasonography, testicular calculus must be kept in mind in differential diagnosis. Further reports on this topic may let us do more clear recommendations about the etiology and treatment of this rare disease.

  4. Liposomal nanocarriers for tumor imaging.

    PubMed

    Erdogan, Suna

    2009-04-01

    Currently used imaging modalities such as scintigraphy, computed tomography, magnetic resonance imaging and ultrasonography require the sufficient intensity of a corresponding signal from an area of interest to differentiate this area from the surrounding tissues. Targeting of various reporter moieties directly to the specific organs, tissues or tumors provide the highest dose of drug directly where it is needed. Many different types of nanoparticles are currently being studied for applications in nanomedicine. Among particulate drug carriers, liposomes are one of the most extensively studied and possess the most suitable characteristics for encapsulation of many drugs, genes, and diagnostic (imaging) agents. Among the many potential targets for such nanocarriers, tumors have been most often investigated. This review attempts to summarize the currently available information regarding liposomal nanocarriers for cancer imaging.

  5. Scapulothoracic bursitis in a patient with quadriparesis: a case report.

    PubMed

    Seol, Seung Jun; Han, Seung Hoon

    2015-04-01

    Scapulothoracic bursitis is a rare disease and presents as pain or swelling around the bursa of the scapulothoracic articulation. It has been reported to be related to chronic repetitive mechanical stress of the periscapular tissue, trauma, overuse, and focal muscle weakness. The authors experienced an atypical case of scapulothoracic bursitis with shoulder and periscapular pain after quadriparesis.This case implies that muscular atrophy around the scapula and chest wall from quadriparesis may contribute to the development of scapulothoracic bursitis with shoulder and periscapular pain. In addition, clinician should be alert to it as a possible cause when a patient with quadriparesis complains of shoulder and periscapular pain and consider proper diagnostic options such as ultrasonography or magnetic resonance imaging.

  6. Scapulothoracic Bursitis in a Patient With Quadriparesis

    PubMed Central

    Seol, Seung Jun; Han, Seung Hoon

    2015-01-01

    Abstract Scapulothoracic bursitis is a rare disease and presents as pain or swelling around the bursa of the scapulothoracic articulation. It has been reported to be related to chronic repetitive mechanical stress of the periscapular tissue, trauma, overuse, and focal muscle weakness. The authors experienced an atypical case of scapulothoracic bursitis with shoulder and periscapular pain after quadriparesis. This case implies that muscular atrophy around the scapula and chest wall from quadriparesis may contribute to the development of scapulothoracic bursitis with shoulder and periscapular pain. In addition, clinician should be alert to it as a possible cause when a patient with quadriparesis complains of shoulder and periscapular pain and consider proper diagnostic options such as ultrasonography or magnetic resonance imaging. PMID:25906107

  7. [Pyometra and persistent hymen in an alpaca].

    PubMed

    Egloff, C; Gerspach, C; Rütten, M; Dettwiler, M; Reichler, I; Bleul, U

    2013-01-01

    A 3-year-old female alpaca was referred to the hospital because of tenesmus. Clinical examination revealed a habitual vaginal prolapse with tenesmus during urination and defecation. On vaginoscopic examination a persistent hymen was detected. Ultrasonography of the caudal abdomen showed an echogenic fluid-filled uterus. A diagnostic laparotomy led to diagnosis of pyometra. Following ovariohysterectomy, the recovery was uneventful. One and a half years later the alpaca was again admitted to the hospital because of colic. Based on the findings, a tentative prognosis was provided and the alpaca was euthanized at the request of the owner. At necropsy, a haemorrhagic infarction of a jejunal loop was found due to incarceration in a fibrous adhesion between the vaginal stump and small intestine.

  8. Accurate evaluation of axillary sentinel lymph node metastasis using contrast-enhanced ultrasonography with Sonazoid in breast cancer: a preliminary clinical trial.

    PubMed

    Matsuzawa, Fumihiko; Omoto, Kiyoka; Einama, Takahiro; Abe, Hironori; Suzuki, Takashi; Hamaguchi, Jun; Kaga, Terumi; Sato, Mami; Oomura, Masako; Takata, Yumiko; Fujibe, Ayako; Takeda, Chie; Tamura, Etsuya; Taketomi, Akinobu; Kyuno, Kenichi

    2015-01-01

    Breast cancer is the most common type of cancer in women. The 5-year survival rate in patients with breast cancer ranges from 74 to 82 %. Sentinel lymph node biopsy has become an alternative to axillary lymph node dissection for nodal staging. We evaluated the detection of the sentinel lymph node and metastasis of the lymph node using contrast enhanced ultrasonography with Sonazoid. Between December 2013 and May 2014, 32 patients with operable breast cancer were enrolled in this study. We evaluated the detection of axillary sentinel lymph nodes and the evaluation of axillary lymph nodes metastasis using contrast enhanced computed tomography, color Doppler ultrasonography and contrast enhanced ultrasonography with Sonazoid. All the sentinel lymph nodes were identified, and the sentinel lymph nodes detected by contrast enhanced ultrasonography with Sonazoid corresponded with those detected by computed tomography lymphography and indigo carmine method. The detection of metastasis based on contrast enhanced computed tomography were sensitivity 20.0 %, specificity 88.2 %, PPV 60.0 %, NPV 55.6 %, accuracy 56.3 %. Based on color Doppler ultrasonography, the results were sensitivity 36.4 %, specificity 95.2 %, PPV 80.0 %, NPV 74.1 %, accuracy 75.0 %. Based on contrast enhanced ultrasonography with Sonazoid, the results were sensitivity 81.8 %, specificity 95.2 %, PPV 90.0 %, NPV 90.9 %, accuracy 90.6 %. The results suggested that contrast enhanced ultrasonography with Sonazoid was the most accurate among the evaluations of these modalities. In the future, we believe that our method would take the place of conventional sentinel lymph node biopsy for an axillary staging method.

  9. Effective use of flow-spoiled FBI and time-SLIP methods in the diagnostic study of an aberrant vessel of the head and neck: "left jugular venous steal by the right jugular vein".

    PubMed

    Kogure, Taroh; Kogure, Kyuya; Iizuka, Mitsumasa; Ino, Azusa; Ishii, Masako

    2010-08-01

    Three-dimensional (3D) time-of-flight (TOF) is now commonly used in routine magnetic resonance angiography (MRA) studies of the head and neck. However, there are limits to its diagnostic abilities in the clinical field and, in some instances, a more invasive supplementary examination may be required. We incidentally discovered a patient with an aberrant vessel of the head and neck that ran alongside the left carotid artery and contained a constant, slowly pulsating efferent blood flow. 3D-TOF and carotid ultrasonography could not determine the nature and origin of this vessel. Additional studies using flow-spoiled fresh blood imaging (flow-spoiled FBI) and time spatial labeling inversion pulse (time-SLIP) methods were effective in determining that the vessel was the left jugular vein, and that the continuous venous reflux was a result of a venous steal by the right jugular vein. We show that by combining different MRA techniques we can effectively achieve diagnosis without resorting to more invasive examinations. 2010 Wiley-Liss, Inc.

  10. Computer-aided diagnostic system for diffuse liver diseases with ultrasonography by neural networks

    NASA Astrophysics Data System (ADS)

    Ogawa, K.; Fukushima, M.; Kubota, K.; Hisa, N.

    1998-12-01

    The aim of the study is to establish a computer-aided diagnostic system for diffuse liver diseases such as chronic active hepatitis (CAH) and liver cirrhosis (LC). The authors introduced an artificial neural network in the classification of these diseases. In this system the neural network was trained by feature parameters extracted from B-mode ultrasonic images of normal liver (NL), CAH and LC. For input data the authors used six parameters calculated by a region of interest (ROI) and a parameter calculated by five ROIs in each image. They were variance of pixel values, coefficient of variation, annular Fourier power spectrum, longitudinal Fourier power spectrum which were calculated for the ROI, and variation of the means of the five ROIs. In addition, the authors used two more parameters calculated from a co-occurrence matrix of pixel values in the ROI. The results showed that the neural network classifier was 83.8% in sensitivity for LC, 90.0% in sensitivity for CAH and 93.6% in specificity, and the system was considered to be helpful for clinical and educational use.

  11. Horner syndrome after unsuccessful venous port implantation by cannulation of the right internal jugular vein.

    PubMed

    Nowak, Łukasz R; Duda, Krzysztof; Mizianty, Marek; Wilczek, Małgorzata; Bieda, Tomasz

    2015-01-01

    Horner syndrome is a rare but likely underdiagnosed complication of internal jugular vein cannulation. We present a case of a young woman undergoing chemotherapy for gestational trophoblastic disease for whom venous port implantation was attempted due to poor peripheral vein access. Despite ultrasound guidance, the procedure was unsuccessful and complicated by a local haematoma, causing compression of the sympathetic nerves with Horner syndrome. The symptoms subsided within 3 weeks without treatment. The possible pathomechanisms of Horner syndrome after central venous cannulation are presented with suggested diagnostic and therapeutic approaches. Special emphasis must be placed on excluding carotid artery dissection because it carries the risk of subsequent cerebral vascular incidents. In the event of a carotid dissection, a multidisciplinary team must choose a pharmacological (antiplatelet drugs/anticoagulation) or interventional approach. Even with ultrasonography, central venous cannulation is not free of serious risks. In case of anisocoria following an uneventful procedure, diagnostic imaging of the vascular structures in the neck is mandatory for the exclusion of potentially serious complications, such as carotid dissection or venous thrombosis.

  12. Examination of acetabular labral tear: a continued diagnostic challenge.

    PubMed

    Reiman, Michael P; Mather, Richard C; Hash, Thomas W; Cook, Chad E

    2014-02-01

    Acetabular labrum tears (ALT) are present in 22-55% of individuals with hip or groin pain. Tears can occur as a result of trauma or degeneration and are markedly associated with femoral acetabular morphological variations. An ALT can lead to biomechanical deficiencies and a loss of stability to the coxafemoral joint due to the labrum serving as a stabilising structure of this joint. The diagnosis of ALT is complex and multidimensional. Although tremendous improvements in diagnostic utility for ALT have occurred in the past 25 years, there are few patient history, clinical examination and special test findings that are unique to the condition. Imaging methods such as MRI, CT and ultrasonography have demonstrated reasonable accuracy, but not at a level that allows use as a stand-alone measure. Outcomes measures that focus on functional limitation or that are used to measure recovery should envelop the complexities of the condition and be captured using both self-report and physical performance measures. Only when patient history, objective testing, clinical examination special testing and imaging are combined can a clinician fully elucidate the multidimensional diagnosis of ALT.

  13. Point-of-care ultrasonography by pediatric emergency physicians. Policy statement.

    PubMed

    Marin, Jennifer R; Lewiss, Resa E

    2015-04-01

    Point-of-care ultrasonography is increasingly being used to facilitate accurate and timely diagnoses and to guide procedures. It is important for pediatric emergency physicians caring for patients in the emergency department to receive adequate and continued point-of-care ultrasonography training for those indications used in their practice setting. Emergency departments should have credentialing and quality assurance programs. Pediatric emergency medicine fellowships should provide appropriate training to physician trainees. Hospitals should provide privileges to physicians who demonstrate competency in point-of-care ultrasonography. Ongoing research will provide the necessary measures to define the optimal training and competency assessment standards. Requirements for credentialing and hospital privileges will vary and will be specific to individual departments and hospitals. As more physicians are trained and more research is completed, there should be one national standard for credentialing and privileging in point-of-care ultrasonography for pediatric emergency physicians.

  14. Should Complete and Incomplete Spinal Cord Injury Patients Receive the Same Attention in Urodynamic Evaluations and Ultrasonography Examinations of the Upper Urinary Tract?

    ERIC Educational Resources Information Center

    Akkoc, Yesim; Cinar, Yasemin; Kismali, Erkan

    2012-01-01

    The aim of the study was to compare urodynamic findings and upper urinary tract (UUT) abnormalities detected by ultrasonography in complete and incomplete suprasacral spinal cord injury (SCI) patients with neurogenic detrusor overactivity. Thirty-eight suprasacral SCI patients who underwent ultrasonography evaluation of the UUT and urodynamic…

  15. Ultrasonography and progesterone concentration at a single time point for the detection of puberty in dairy heifers.

    PubMed

    Archbold, H; Buckley, F; Pierce, K M; Begley, N; Mee, J F

    2012-06-01

    Data were available from 1657 heifers across 48 dairy farms which were visited once, on average 9 days (± 5.2) prior to the mating start date (23 April, ± 12.6). Blood samples were collected via coccygeal venepuncture for progesterone (P4) analysis, and animals were scanned for the presence or absence of corpora lutea (CL), to determine the luteal status. A comparison of luteal status between ultrasound (CL identified) and P4 (≥ 1 ng/ml), based on a single measurement point, showed poor agreement (K = 0.32). The majority of animals were classified as luteal (76%) using both ultrasonography and P4. There was excellent agreement between luteal status detected by ultrasonography alone and luteal status assigned by a combination of ultrasonography and P4 (K = 0.93). The agreement between luteal status assigned by P4 and luteal status assigned by the combination of ultrasonography and P4 was poor (K = 0.37). These results indicate that at a single examination, ultrasonography is the preferred modality to determine the luteal status of maiden heifers. © 2011 Blackwell Verlag GmbH.

  16. [Integrated study of fecal incontinence with defecography, anal ultrasonography, perineography, and manometry].

    PubMed

    Salzano, A; De Rosa, A; Amodio, F; Vallone, G; Pinto, A; Carbone, M; Gesuè, G; De Angelis, P

    1998-12-01

    Imaging methods such as defecography, anal US and perineography, combined with manometry, now permit to identify a growing number of causes of anorectal and pelvic floor deficiency. Fecal incontinence patients can thus be approached correctly relative to both diagnosis and treatment. We investigated the role of these techniques in the work-up of fecal incontinence. Thirty-eight subjects suffering from fecal incontinence were examined. Defecography was carried out with a special commode and videorecorded on a VHS cassette. Anal US was performed with a 7-MHz rotating probe (type 1846) with 3-cm focus length. Perineography was carried out in 15 female patients. The anorectal angle (ARA) at rest was increased (mean: 106 degrees; normal range: 90-100 degrees) in 34 cases; involuntary barium leakage was seen in 8 patients, especially on coughing. On squeezing, ARA was normal in 10 cases (mean: 72 degrees; normal range: 60-90 degrees); in 5 cases of puborectal hypotonia there was no angular excursion between rest and squeezing (mean: 105 degrees). During evacuation, the average ARA value was 166 degrees in 21 cases and ARA stretched to verticalization in 8 cases (mean: 179 degrees). Morphofunctional anorectal changes appeared as rectal mucosal prolapse (12 cases), rectocele (10 cases), perineal descent syndrome (8 cases) and external rectal prolapse (3 cases). Anal US identified 15 interruptions in sphincterial rings: 12 patterns were hypoechoic, 2 mixed and 1 hyperechoic. Atrophic thinning of internal anal sphincter was seen in 5 idiopathic incontinence patients. Perineography demonstrated cystocele in 5 cases and cystourethrocele in 1 case. Manometry showed sphincterial hypotonia at rest in 15 cases, lower values of anorectal pressure on squeezing in 8 and smaller air volumes inhibiting external sphincterial tone in 19 cases. Defecographic studies with evaluation of ARA and its changes are an important tool with high diagnostic yield. When combined with other techniques, they provide differential criteria for sphincterial and puborectal causes and permits to identify associated pelvic floor dysfunctions. We believe that defecography, anal US (and perineography in complex disorders) are necessary techniques for the correct clinical approach to fecal incontinence patients, whose role and diagnostic yield are a valid support to manometry.

  17. Accuracy of Physical Examination, Ultrasonography, and Mammography in Predicting Residual Pathologic Tumor Size in Patients Treated With Neoadjuvant Chemotherapy

    PubMed Central

    Chagpar, Anees B.; Middleton, Lavinia P.; Sahin, Aysegul A.; Dempsey, Peter; Buzdar, Aman U.; Mirza, Attiqa N.; Ames, Fredrick C.; Babiera, Gildy V.; Feig, Barry W.; Hunt, Kelly K.; Kuerer, Henry M.; Meric-Bernstam, Funda; Ross, Merrick I.; Singletary, S Eva

    2006-01-01

    Objective: To assess the accuracy of physical examination, ultrasonography, and mammography in predicting residual size of breast tumors following neoadjuvant chemotherapy. Background: Neoadjuvant chemotherapy is an accepted part of the management of stage II and III breast cancer. Accurate prediction of residual pathologic tumor size after neoadjuvant chemotherapy is critical in guiding surgical therapy. Although physical examination, ultrasonography, and mammography have all been used to predict residual tumor size, there have been conflicting reports about the accuracy of these methods in the neoadjuvant setting. Methods: We reviewed the records of 189 patients who participated in 1 of 2 protocols using doxorubicin-containing neoadjuvant chemotherapy, and who had assessment by physical examination, ultrasonography, and/or mammography no more than 60 days before their surgical resection. Size correlations were performed using Spearman rho analysis. Clinical and pathologic measurements were also compared categorically using the weighted kappa statistic. Results: Size estimates by physical examination, ultrasonography, and mammography were only moderately correlated with residual pathologic tumor size after neoadjuvant chemotherapy (correlation coefficients: 0.42, 0.42, and 0.41, respectively), with an accuracy of ±1 cm in 66% of patients by physical examination, 75% by ultrasonography, and 70% by mammography. Kappa values (0.24–0.35) indicated poor agreement between clinical and pathologic measurements. Conclusion: Physical examination, ultrasonography, and mammography were only moderately useful for predicting residual pathologic tumor size after neoadjuvant chemotherapy. PMID:16432360

  18. Diagnostic ultrasound at MACH 20: retroperitoneal and pelvic imaging in space.

    PubMed

    Jones, J A; Sargsyan, A E; Barr, Y R; Melton, S; Hamilton, D R; Dulchavsky, S A; Whitson, P A

    2009-07-01

    An operationally available diagnostic imaging capability augments spaceflight medical support by facilitating the diagnosis, monitoring and treatment of medical or surgical conditions, by improving medical outcomes and, thereby, by lowering medical mission impacts and the probability of crew evacuation due to medical causes. Microgravity-related physiological changes occurring during spaceflight can affect the genitourinary system and potentially cause conditions such as urinary retention or nephrolithiasis for which ultrasonography (U/S) would be a useful diagnostic tool. This study describes the first genitourinary ultrasound examination conducted in space, and evaluates image quality, frame rate, resolution requirements, real-time remote guidance of nonphysician crew medical officers and evaluation of on-orbit tools that can augment image acquisition. A nonphysician crew medical officer (CMO) astronaut, with minimal training in U/S, performed a self-examination of the genitourinary system onboard the International Space Station, using a Philips/ATL Model HDI-5000 ultrasound imaging unit located in the International Space Station Human Research Facility. The CMO was remotely guided by voice commands from experienced, earth-based sonographers stationed in Mission Control Center in Houston. The crewmember, with guidance, was able to acquire all of the target images. Real-time and still U/S images received at Mission Control Center in Houston were of sufficient quality for the images to be diagnostic for multiple potential genitourinary applications. Microgravity-based ultrasound imaging can provide diagnostic quality images of the retroperitoneum and pelvis, offering improved diagnosis and treatment for onboard medical contingencies. Successful completion of complex sonographic examinations can be obtained even with minimally trained nonphysician ultrasound operators, with the assistance of ground-based real-time guidance.

  19. PIVKA-II is a useful tool for diagnostic characterization of ultrasound-detected liver nodules in cirrhotic patients

    PubMed Central

    Saitta, Carlo; Raffa, Giuseppina; Alibrandi, Angela; Brancatelli, Santa; Lombardo, Daniele; Tripodi, Gianluca; Raimondo, Giovanni; Pollicino, Teresa

    2017-01-01

    Abstract Protein induced by vitamin K absence-II (PIVKA-II) is a potential screening marker for hepatocellular carcinoma (HCC). Limited data are available about its utility in discriminating neoplastic from regenerative nodules at ultrasonography (US) evaluation in cirrhotic patients. Aim of this study was to investigate the diagnostic utility of PIVKA-II in cases showing liver nodules of uncertain diagnosis at US. Ninety cirrhotics with US evidence of liver nodule(s) were enrolled. All patients underwent blood sampling within 1 week of US and were thereafter followed up. HCC was confirmed in 40/90 cases, and in all cases it was in a very early/early stage. All sera were tested for PIVKA-II and alpha-fetoprotein (AFP) at the end of follow-up. PIVKA-II at a cut off of 60 mAU/mL was significantly associated with HCC at both univariate and multivariate analysis (P = .016 and P = .032, respectively). AFP at a cut off of 6.5 ng/mL was not associated with HCC at univariate analysis (P = .246). ROC curves showed that PIVKA-II had 60% sensitivity, 88% specificity, 80% positive predictive value (PPV), and 73% negative predictive value (NPV), whereas AFP had 67% sensitivity, 68% specificity, 63% PPV, and 72% NPV. AUROC curves showed that the combination of both biomarkers increased the diagnostic accuracy for HCC (AUC 0.76; sensitivity 70%, specificity 94%, PPV 91%, and NPV 79%). In conclusion, PIVKA-II is a useful tool for the diagnostic definition of US-detected liver nodules in cirrhotic patients, and it provides high diagnostic accuracy for HCC when combined with AFP. PMID:28658121

  20. The use of intrathecal analgesia and contrast radiography as preoperative diagnostic methods for digital flexor tendon sheath pathology.

    PubMed

    Fiske-Jackson, A R; Barker, W H J; Eliashar, E; Foy, K; Smith, R K W

    2013-01-01

    The sensitivity of ultrasonography for the diagnosis of manica flexoria (MF) tears within the digital flexor tendon sheath (DFTS) is lower than for diagnosis of marginal tears of the deep digital flexor tendon (DDFT). Additional diagnostic tools would assist in appropriate decision making for either conservative or surgical management. To evaluate the improvement in lameness of horses with MF or DDFT tears following intrathecal analgesia and to assess the sensitivity and specificity of contrast radiography for the diagnosis of these tears. The case records of horses presented to a referral clinic over a 7-year period that underwent intrathecal diagnostic analgesia, or intrathecal analgesia and contrast radiography, of the DFTS with subsequent tenoscopy were examined. Fifty-three limbs had intrathecal diagnostic analgesia performed and 23 contrast tenograms were assessed in horses undergoing DFTS tenoscopy. Horses with DDFT tears were significantly more likely to respond positively to intrathecal diagnostic analgesia than those with MF tears (P = 0.02). Using contrast radiography, tears of the MF were predicted with an overall sensitivity of 96% and specificity of 80%; marginal tears of the DDFT were predicted with an overall sensitivity of 57% and specificity of 84%. The results of intrathecal analgesia of the DFTS in combination with contrast radiography have a high sensitivity for predicting MF tears. The sensitivity of contrast radiography for predicting tears of the DDFT is lower but the specificity remains high. Contrast radiography performed at the same time as intrathecal analgesia provides useful information regarding the presence of MF tears and DDFT tears, which can assist in the decision of whether to manage the lameness conservatively or with tenoscopic evaluation. © 2012 EVJ Ltd.

  1. Evaluation of clinical breast examination and breast ultrasonography among pregnant women in Abakaliki, Nigeria

    PubMed Central

    Ezeonu, Paul Olisaemeka; Ajah, Leonard Ogbonna; Onoh, Robinson Chukwudi; Lawani, Lucky Osaheni; Enemuo, Vincent Chidi; Agwu, Uzoma MaryRose

    2015-01-01

    Background Breast cancer in pregnancy accounts for 2%–3% of all breast cancers. The increased vascularity and lymphatic drainage from the breast during pregnancy potentiate the metastatic spread of the cancer to the regional lymph nodes. However, the increased breast density in pregnancy makes it difficult to detect breast lesions early. Aim To evaluate and compare the detection rate of breast lesions using clinical breast examination (CBE) and breast ultrasonography among pregnant women. Methodology A cross-sectional comparative study involving antenatal clinic attendees at the Federal Teaching Hospital, Abakaliki, was conducted between March 3, 2014, and December 31, 2014. CBE and breast ultrasonography were done in the participants at booking and repeated at 6 weeks postpartum. Fine-needle aspiration cytology and histology were done in women with suspicious breast lesions on CBE or breast ultrasonography or both. Data analysis was both descriptive and inferential at the 95% confidence level using the Statistical Package for the Social Sciences (SPSS) software version 17.0. Test of significance was done using chi-square test. A P-value of less than or equal to 0.05 was considered statistically significant. Results A total of 320 pregnant women participated in the study. Of these, 267 (83.4%) were aware of breast cancer. Although more lesions were detected with breast ultrasonography than by CBE, there was no statistically significant difference between them (25 versus 17; P=0.26). The histology of the lesions revealed 21 benign lesions and 4 normal breast tissues. The sensitivity of breast ultrasonography was 95.2%, while that of CBE was 66.7%. The specificity, positive predictive value, and negative predictive value were similar between CBE and breast ultrasonography. Conclusion The detection rates of breast lesions by both CBE and breast ultrasonography were equivalent during pregnancy and 6 weeks postpartum, making CBE a convenient and very cost-effective method of detecting breast lesions in the low-risk population. However, both CBE and breast ultrasonography should be done in women with high risk of breast malignancy. PMID:25999736

  2. [The difficulty of prenatal diagnosis of Kniest's disease. Apropos of a case simulating congenital spondylo-epiphyseal dysplasia].

    PubMed

    Kerleroux, J; Roux, M S; Cottin, X

    1994-01-01

    The second antenatal diagnosis of Kniest's syndrome is described in this report. This skeletal dysplasia involving disproportional dwarfism and a flat facies is compatible with life and normal intelligence. The authors describe the observed sonographic imagery and emphasize the important role of ultrasonography for antenatal evaluation of the prognosis of the skeletal dysplasias. The main differential diagnosis is spondylo-epiphyseal dysplasia congenita.

  3. Effect of Provider Experience on Clinician-Performed Ultrasonography for Hydronephrosis in Patients With Suspected Renal Colic

    PubMed Central

    Herbst, Meghan K.; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P.; Singh, Dinesh; Molinaro, Annette M.; Luty, Seth; Moore, Christopher L.

    2016-01-01

    Study objective Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. Methods This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non–attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non–attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). Results There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95% confidence interval [CI] 65.4% to 78.9%), specificity of 73.3% (95% CI 66.1% to 79.4%), positive likelihood ratio of 2.72 (95% CI 2.25 to 3.27), and negative likelihood ratio of 0.37 (95% CI 0.31 to 0.44) for hydronephrosis, using hydronephrosis on CT as the criterion standard. Among attending physicians with fellowship training, ultrasonography had sensitivity of 92.7% (95% CI 83.8% to 96.9%), positive likelihood ratio of 4.97 (95% CI 2.90 to 8.51), and negative likelihood ratio of 0.08 (95% CI 0.03 to 0.23). Conclusion Overall, ultrasonography performed by emergency clinicians was moderately sensitive and specific for detection of hydronephrosis as seen on CT in patients with suspected renal colic. However, presence or absence of hydronephrosis as determined by emergency physicians with fellowship training in ultrasonography yielded more definitive test results. For clinicians without fellowship training, there was no significant difference between groups in the predictive accuracy of the application according to experience level. PMID:24630203

  4. Effect of provider experience on clinician-performed ultrasonography for hydronephrosis in patients with suspected renal colic.

    PubMed

    Herbst, Meghan K; Rosenberg, Graeme; Daniels, Brock; Gross, Cary P; Singh, Dinesh; Molinaro, Annette M; Luty, Seth; Moore, Christopher L

    2014-09-01

    Hydronephrosis is readily visible on ultrasonography and is a strong predictor of ureteral stones, but ultrasonography is a user-dependent technology and the test characteristics of clinician-performed ultrasonography for hydronephrosis are incompletely characterized, as is the effect of ultrasound fellowship training on predictive accuracy. We seek to determine the test characteristics of ultrasonography for detecting hydronephrosis when performed by clinicians with a wide range of experience under conditions of direct patient care. This was a prospective study of patients presenting to an academic medical center emergency department with suspected renal colic. Before computed tomography (CT) results, an emergency clinician performed bedside ultrasonography, recording the presence and degree of hydronephrosis. CT data were abstracted from the dictated radiology report by an investigator blinded to the bedside ultrasonographic results. Test characteristics of bedside ultrasonography for hydronephrosis were calculated with the CT scan as the reference standard, with test characteristics compared by clinician experience stratified into 4 levels: attending physicians with emergency ultrasound fellowship training, attending physicians without emergency ultrasound fellowship training, ultrasound experienced non-attending physician clinicians (at least 2 weeks of ultrasound training), and ultrasound inexperienced non-attending physician clinicians (physician assistants, nurse practitioners, off-service rotators, and first-year emergency medicine residents with fewer than 2 weeks of ultrasound training). There were 670 interpretable bedside ultrasonographic tests performed by 144 unique clinicians, 80.9% of which were performed by clinicians directly involved in the care of the patient. On CT, 47.5% of all subjects had hydronephrosis and 47.0% had a ureteral stone. Among all clinicians, ultrasonography had a sensitivity of 72.6% (95% confidence interval [CI] 65.4% to 78.9%), specificity of 73.3% (95% CI 66.1% to 79.4%), positive likelihood ratio of 2.72 (95% CI 2.25 to 3.27), and negative likelihood ratio of 0.37 (95% CI 0.31 to 0.44) for hydronephrosis, using hydronephrosis on CT as the criterion standard. Among attending physicians with fellowship training, ultrasonography had sensitivity of 92.7% (95% CI 83.8% to 96.9%), positive likelihood ratio of 4.97 (95% CI 2.90 to 8.51), and negative likelihood ratio of 0.08 (95% CI 0.03 to 0.23). Overall, ultrasonography performed by emergency clinicians was moderately sensitive and specific for detection of hydronephrosis as seen on CT in patients with suspected renal colic. However, presence or absence of hydronephrosis as determined by emergency physicians with fellowship training in ultrasonography yielded more definitive test results. For clinicians without fellowship training, there was no significant difference between groups in the predictive accuracy of the application according to experience level. Copyright © 2014 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  5. Cardiovascular ultrasonography detection of embolic sources in trauma.

    PubMed

    Saranteas, Theodosios; Mavrogenis, Andreas F; Poularas, John; Kostroglou, Andreas; Mandila, Christina; Panou, Fotios

    2018-06-01

    Venous thromboembolism (deep vein thrombosis and pulmonary embolism) and bone cement implantation syndrome are major sources of embolic events in trauma patients. In these patients, embolic events due to venous thromboembolism and bone cement implantation syndrome have been detected with cardiac and vascular ultrasonography in the emergency setting, during the perioperative period, and in the intensive care unit. This article discusses the ultrasonography modalities and imaging findings of embolic events related to venous thromboembolism and bone cement implantation syndrome. The aim is to present a short review with exceptional illustrations that can enable physicians to identify sources of emboli in trauma patients with cardiovascular ultrasonography. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    PubMed Central

    2015-01-01

    Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents. PMID:25754367

  7. Characterization of the biliary tract by virtual ultrasonography constructed by gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging.

    PubMed

    Koizumi, Yohei; Hirooka, Masashi; Ochi, Hironori; Tokumoto, Yoshio; Takechi, Megumi; Hiraoka, Atsushi; Ikeda, Yoshio; Kumagi, Teru; Matsuura, Bunzo; Abe, Masanori; Hiasa, Yoichi

    2015-04-01

    This study aimed at prospectively evaluating bile duct anatomy on ultrasonography and evaluating the safety and utility of radiofrequency ablation (RFA) assisted by virtual ultrasonography from gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). The institutional review board approved this study, and patients provided written informed consent prior to entry into the study. Bile duct anatomy was assessed in 201 patients who underwent Gd-EOB-DTPA-enhanced MRI for the evaluation of hepatic tumor. Eighty-one of these patients subsequently underwent RFA assisted by ultrasound imaging. In 23 patients, the tumor was located within 5 mm of the central bile duct, as demonstrated by MRI. Virtual ultrasonography constructed by Gd-EOB-enhanced MRI was able to visualize the common bile duct, left hepatic duct, and right hepatic duct in 96.5, 94.0, and 89.6 % of cases, respectively. The target hepatic tumor nodule and biliary duct could be detected with virtual ultrasonography in all patients, and no severe complications occurred. The running pattern of the bile ducts could be recognized on conventional ultrasound by referencing virtual ultrasonography constructed by Gd-EOB-DTPA-enhanced MRI. RFA assisted by this imaging strategy did not result in bile duct injury.

  8. Hyperthyroidism, hyperfunctioning thyroid nodule, and thyroid cancer in a young female: a rare and unusual coexistence.

    PubMed

    Hernán-Martínez, José; Uzcategui, María; Corder, Eric; Castillo, Manuel; Sostre, Samuel; Alicea, Luz

    2010-03-01

    The prevalence of concomitant thyroid carcinoma with Grave's disease has been reported to range from 0 to 10%. Many controversies exist in the literature regarding the diagnostic workup and management in these types of patients. We are reporting a case of a 31 year old woman who had Graves' disease, a palpable thyroid nodule, and results from a thyroid scan revealed a "hot" nodule. Interestingly, an ultrasound guided FNA of the "hot" nodule showed papillary thyroid microcarcinoma. Finally, a total thyroidectomy showed multilobar tumor involvement. The diagnostic tools employed to establish the proper management strategy for this patient were based on data in the literature that is full of discrepancies. The fact that Grave's disease occurs concomitantly with thyroid cancer, specifically the papillary type, is an indisputably rare combination. One rare feature on our clinical case was the reported malignancy of a papillary carcinoma within a "hot" nodule which usually is much less that 1%. Many studies describe an increasing incidence of Grave's disease patients with concomitant papillary thyroid carcinoma. One possible explanation for these findings could be improvements in medical technology of screening tools. We propose that, thyroid ultrasonography should be integrated in the diagnostic workup in patients presenting with Graves' disease, especially in those presenting with palpable nodules. Fine needle biopsy should not be restricted to cold nodules.

  9. [Differential diagnostic value of real-time tissue elastography and three dimensional ultrasound imaging in breast lumps].

    PubMed

    Li, M H; Liu, Y; Liu, L S; Li, P X; Chen, Q

    2016-05-24

    To investigate the real-time tissue elastography and 3D contrast-enhanced ultrasonography(CEUS) in breast lumps differential diagnostic value. A total of 126 patients (180 lumps) with breast mass were retrospectively analyzed from December 2012 to December 2014 in Tumor Hospital Affiliated To Xinjiang Medical University.All patients were divided into three groups by using stratified random method.Each group was detected by real-time tissue elastography, 3D CEUS and two joint inspection.Each group of 42 cases (60 lumps) was confirmed by the pathological results as gold standard.Diagnostic sensitivity, specificity and coincidence rate of different methods were compared. The benign masses of ultrasound contrast showed the punctate, linear and nodular enhancement, and the border of enhancement was smooth.The malignant tumors were mainly dominated by uneven and high enhancement. There was no statistical difference in sensitivity, specificity and coincidence rate between elastography group and 3D CEUS group (64.7% vs 73.5%, 69.2% vs 76.9%, 66.7% vs 75.0%, all P>0.05). The sensitivity, specificity and coincidence rate of two joint inspection group were higher than those of elastography group and 3D CEUS group, the differences were statistically significant (97.1%, 92.3% and 98.3% , all P<0.05). 3D CEUS combined with real-time tissue elastography is of high value in the diagnosis of breast masses.

  10. Eye and orbit ultrasound

    MedlinePlus

    Echography - eye orbit; Ultrasound - eye orbit; Ocular ultrasonography; Orbital ultrasonography ... eye is numbed with medicine (anesthetic drops). The ultrasound wand (transducer) is placed against the front surface ...

  11. Hip Imaging in Athletes: Sports Imaging Series.

    PubMed

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  12. Imaging of common breast implants and implant-related complications: A pictorial essay

    PubMed Central

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer. PMID:27413269

  13. The emergence of diagnostic imaging technologies in breast cancer: discovery, regulatory approval, reimbursement, and adoption in clinical guidelines.

    PubMed

    Gold, Laura S; Klein, Gregory; Carr, Lauren; Kessler, Larry; Sullivan, Sean D

    2012-01-25

    In this article, we trace the chronology of developments in breast imaging technologies that are used for diagnosis and staging of breast cancer, including mammography, ultrasonography, magnetic resonance imaging, computed tomography, and positron emission tomography. We explore factors that affected clinical acceptance and utilization of these technologies from discovery to clinical use, including milestones in peer-reviewed publication, US Food and Drug Administration approval, reimbursement by payers, and adoption into clinical guidelines. The factors driving utilization of new imaging technologies are mainly driven by regulatory approval and reimbursement by payers rather than evidence that they provide benefits to patients. Comparative effectiveness research can serve as a useful tool to investigate whether these imaging modalities provide information that improves patient outcomes in real-world settings.

  14. [The Mexican Institute of Social Security Institute (IMSS) in Numbers. Functional inventory of imaging medical equipment, 2003].

    PubMed

    2005-01-01

    Medical technology is a fundamental instrument for the provision of health services in the Mexican Institute of Social Security (IMSS) and as a support for diagnostic and therapeutic interventions. The inventory of relevant medical equipment describes the needs for upgrading the technological infrastructure, organize its distribution and plan its renovation in order to guarantee the quality of health services. In this report we describe the type of equipment used in radiology and other imaging services, its geographical distribution, median age in operation and its productivity. The inventory reported 2091 pieces of equipment, ultrasonography and radiology were the most common types (31%) followed by fluoroscopic equipment (20%). Follow-up in the inventory should help in planning the acquisition and maintenance of sophisticated technology used for medical purposes.

  15. Imaging of common breast implants and implant-related complications: A pictorial essay.

    PubMed

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  16. Expert consensus document: Advances in the evaluation of anorectal function.

    PubMed

    Carrington, Emma V; Scott, S Mark; Bharucha, Adil; Mion, François; Remes-Troche, Jose M; Malcolm, Allison; Heinrich, Henriette; Fox, Mark; Rao, Satish S

    2018-05-01

    Faecal incontinence and evacuation disorders are common, impair quality of life and incur substantial economic costs worldwide. As symptoms alone are poor predictors of underlying pathophysiology and aetiology, diagnostic tests of anorectal function could facilitate patient management in those cases that are refractory to conservative therapies. In the past decade, several major technological advances have improved our understanding of anorectal structure, coordination and sensorimotor function. This Consensus Statement provides the reader with an appraisal of the current indications, study performance characteristics, clinical utility, strengths and limitations of the most widely available tests of anorectal structure (ultrasonography and MRI) and function (anorectal manometry, neurophysiological investigations, rectal distension techniques and tests of evacuation, including defecography). Additionally, this article provides our consensus on the clinical relevance of these tests.

  17. MR Imaging of the Penis and Scrotum.

    PubMed

    Parker, Rex A; Menias, Christine O; Quazi, Robin; Hara, Amy K; Verma, Sadhna; Shaaban, Akram; Siegel, Cary L; Radmanesh, Alireza; Sandrasegaran, Kumar

    2015-01-01

    Traditionally, due to its low cost, ready availability, and proved diagnostic accuracy, ultrasonography (US) has been the primary imaging modality for the evaluation of scrotal and, to a lesser extent, penile disease. However, US is limited by its relatively small useful field of view, operator dependence, and inability to provide much information on tissue characterization. Magnetic resonance (MR) imaging, with its excellent soft-tissue contrast and good spatial resolution, is increasingly being used as both a problem-solving tool in patients who have already undergone US and as a primary modality for the evaluation of suspected disease. Specifically, MR imaging can aid in differentiating between benign and malignant lesions seen at US, help define the extent of inflammatory processes or traumatic injuries, and play a vital role in locoregional staging of tumors. Consequently, it is becoming more important for radiologists to be familiar with the wide range of penile and scrotal disease entities and their MR imaging appearances. The authors review the basic anatomy of the penis and scrotum as seen at MR imaging and provide a basic protocol for penile and scrotal imaging, with emphasis on the advantages of MR imaging. Pathologic processes are organized into traumatic (including penile fracture and contusion), infectious or inflammatory (including Fournier gangrene and scrotal abscess), and neoplastic (including both benign and malignant scrotal and penile tumors) processes. ©RSNA, 2015.

  18. Noninvasive Intracranial Pressure Monitoring for Severe Traumatic Brain Injury in Children: A Concise Update on Current Methods.

    PubMed

    Narayan, Vinayak; Mohammed, Nasser; Savardekar, Amey R; Patra, Devi Prasad; Notarianni, Christina; Nanda, Anil

    2018-06-01

    Traumatic brain injury (TBI) is a leading cause of pediatric morbidity and mortality worldwide and intracranial pressure (ICP) monitoring plays a crucial role in its management. Based on existing literature, we review the current practicing noninvasive ICP monitoring devices and their accuracy in predicting increased ICP in pediatric TBI. A thorough literature search was conducted on PubMed, Medline, and the Cochrane database, articles were selected systematically and reviewed completely, and relevant data were summarized and discussed. A total of 27 articles pertaining to pediatric TBI were included and reviewed. We found various modalities of noninvasive ICP monitoring devices used over the last few years. The noninvasive modalities so far attempted in pediatric TBI and so reviewed here are transcranial Doppler, optic nerve sheath diameter, otoacoustic emission, near-infrared spectroscopy, contrast-enhanced ultrasonography, and quantitative pupillometry. Invasive monitoring methods are the current gold standard for monitoring ICP; however, complications caused by their invasive nature are of concern. Of all the noninvasive methods based on the literature, we found transcranial Doppler and optic nerve sheath diameter assessment to be the best tools to monitor ICP in pediatric TBI. The promising results and developments of noninvasive ICP monitoring modalities with its ideal features of high sensitivity, diagnostic accuracy, and simple acquisition technique may make it the future of neurointensive monitoring in pediatric TBI. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. An unanticipated diagnosis with bedside ultrasonography in patients with acute abdominal pain: rectus hematoma

    PubMed Central

    Ünlüer, Erden Erol; Kaykısız, Eylem Kuday

    2017-01-01

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and confirmed as RSH by computed tomography. Review of patient history and use of ultrasonography are important to avoid misdiagnosisof RSH. PMID:28748020

  20. An unanticipated diagnosis with bedside ultrasonography in patients with acute abdominal pain: rectus hematoma.

    PubMed

    Ünlüer, Erden Erol; Kaykısız, Eylem Kuday

    2017-01-01

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and confirmed as RSH by computed tomography. Review of patient history and use of ultrasonography are important to avoid misdiagnosisof RSH.

  1. Strategies to diagnose ovarian cancer: new evidence from phase 3 of the multicentre international IOTA study

    PubMed Central

    Testa, A; Kaijser, J; Wynants, L; Fischerova, D; Van Holsbeke, C; Franchi, D; Savelli, L; Epstein, E; Czekierdowski, A; Guerriero, S; Fruscio, R; Leone, F P G; Vergote, I; Bourne, T; Valentin, L; Van Calster, B; Timmerman, D

    2014-01-01

    Background: To compare different ultrasound-based international ovarian tumour analysis (IOTA) strategies and risk of malignancy index (RMI) for ovarian cancer diagnosis using a meta-analysis approach of centre-specific data from IOTA3. Methods: This prospective multicentre diagnostic accuracy study included 2403 patients with 1423 benign and 980 malignant adnexal masses from 2009 until 2012. All patients underwent standardised transvaginal ultrasonography. Test performance of RMI, subjective assessment (SA) of ultrasound findings, two IOTA risk models (LR1 and LR2), and strategies involving combinations of IOTA simple rules (SRs), simple descriptors (SDs) and LR2 with and without SA was estimated using a meta-analysis approach. Reference standard was histology after surgery. Results: The areas under the receiver operator characteristic curves of LR1, LR2, SA and RMI were 0.930 (0.917–0.942), 0.918 (0.905–0.930), 0.914 (0.886–0.936) and 0.875 (0.853–0.894). Diagnostic one-step and two-step strategies using LR1, LR2, SR and SD achieved summary estimates for sensitivity 90–96%, specificity 74–79% and diagnostic odds ratio (DOR) 32.8–50.5. Adding SA when IOTA methods yielded equivocal results improved performance (DOR 57.6–75.7). Risk of Malignancy Index had sensitivity 67%, specificity 91% and DOR 17.5. Conclusions: This study shows all IOTA strategies had excellent diagnostic performance in comparison with RMI. The IOTA strategy chosen may be determined by clinical preference. PMID:24937676

  2. Diagnostic accuracy of circulating thyrotropin receptor messenger RNA combined with neck ultrasonography in patients with Bethesda III-V thyroid cytology.

    PubMed

    Aliyev, Altay; Patel, Jinesh; Brainard, Jennifer; Gupta, Manjula; Nasr, Christian; Hatipoglu, Betul; Siperstein, Allan; Berber, Eren

    2016-01-01

    The aim of this study was to analyze the usefulness of thyrotropin receptor messenger RNA (TSHR-mRNA) combined with neck ultrasonography (US) in the management of thyroid nodules with Bethesda III-V cytology. Cytology slides of patients with a preoperative fine needle aspiration (FNA) and TSHR-mRNA who underwent thyroidectomy between 2002 and 2011 were recategorized based on the Bethesda classification. Results of thyroid FNA, TSHR-mRNA, and US were compared with the final pathology. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. There were 12 patients with Bethesda III, 112 with Bethesda IV, and 58 with Bethesda V cytology. The sensitivity of TSHR-mRNA in predicting cancer was 33%, 65%, and 79 %, and specificity was 67%, 66%, and 71%, for Bethesda III, IV, and V categories, respectively. For the same categories, the PPV of TSHR-mRNA was 25%, 33%, and 79%, respectively; whereas the NPV was 75%, 88%, and 71%, respectively. The addition of neck US to TSHR-mRNA increased the NPV to 100% for Bethesda III, and 86%, for Bethesda IV, and 82% for Bethesda V disease. This study documents the potential usefulness of TSHR-mRNA for thyroid nodules with Bethesda III-V FNA categories. TSHR-mRNA may be used to exclude Bethesda IV disease. A large sample analysis is needed to determine its accuracy for Bethesda category III nodules. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Effect of ISDN bandwidth on image quality for telemedicine transmission of obstetric ultrasonography.

    PubMed

    Malone, F D; Athanassiou, A; Nores, J; D'Alton, M E

    1998-01-01

    To evaluate objectively the effect of different bandwidths on the ability to interpret obstetric ultrasound scans transmitted live over a commercial telephone network. An integrated services digital network (ISDN) was established from three satellite offices to our central prenatal diagnostic center. In the first half of the study, the network was based on four ISDN channels transmitting at a bandwidth of 256 kbits per second (kbps), while in the second half of the study, this was increased to six ISDN channels transmitting at 384 kbps. A physician trained in obstetric ultrasonography provided an interpretation of fetal anatomy using a live, real-time telemedicine link. A scoring system consisting of 33 anatomic items was used to evaluate image quality objectively. The number of transmissions complicated by motion artifact was also recorded. One hundred patients had a fetal anatomy survey performed using the 256 kbps system, and these interpretations were compared with those from another group of 100 patients who were examined using the 384 kbps system. Although the visibility of the 33 anatomic items was similar using the two systems, significantly more examinations at 256 kbps were complicated by motion artifact (12% vs. 3%; P = 0.02). Remote sonographic viewing of fetal anatomy was adequate using both 256 and 384 kbps systems, although motion artifact was significantly more likely to occur using the slower system. This problem may affect the ability of the lower-bandwidth system to allow optimal detection when fetal anomalies are present.

  4. Prenatal diagnosis of Joubert syndrome: A case report and literature review.

    PubMed

    Zhu, Lingling; Xie, Limei

    2017-12-01

    Joubert syndrome (JS) is a rare autosomal recessive inherited disease belonging to ciliopathy with the causative mutation of genes. Except for X-linked inheritance, the high recurrence rate of a family is about 25%. After birth, it may cause a series of neurological symptoms, even with retina, kidney, liver, and other organ abnormalities, which is defined as Joubert syndrome and related disorders (JSRD). Molecular genetics research contributes to disease prediction and genetic counseling. Prenatal diagnosis is rare. Magnetic resonance imaging (MRI) is usually the first-choice diagnostic modality with typical brain images characterized by the molar tooth sign. We describe a case of JS prenatally and Dandy-Walker malformation for the differential diagnosis based on ultrasonograms. We also review the etiology, imaging features, clinical symptoms, and diagnosis of JSRD. A 22-year-old woman was pregnant at 27 1/7 weeks' gestation with fetal cerebellar vermis hypoplasia. Fetal ultrasonography and MRI confirmed a diagnosis of JS at our center. The couple finally opted to terminate the fetus, which had a normal appearance and growth parameters. The couple also had an AHI1 gene mutation on chromosome 6. Currently, a diagnosis of JS is commonly made after birth. Fewer cases of prenatal diagnosis by ultrasonography have been made, and they are more liable to be misdirected because of some nonspecial features that also manifest in Dandy-Walker malformation, cranio-cerebello-cardiac syndrome, and so on. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  5. Analysis of 777 cases with obstruction of the ureter or extrahepatic bile duct by ultrasonography after normal saline retention enema

    PubMed Central

    2012-01-01

    Background Conventional transabdominal ultrasound usually fails to visualize parts of the ureter or extrahepatic bile duct covered by bowel gas. In this study, we propose a new method for gaining acoustic access to the ureters and extrahepatic bile duct to help determine the nature of obstruction to these structures when conventional transabdominal ultrasound fails. Methods The normal saline retention enema method, that is, using normal saline-filled colons to gain acoustic access to the bilateral ureters and extrahepatic bile duct and detecting the lesions with transabdominal ultrasonic diagnostic apparatus, was applied to 777 patients with obstructive lesions, including 603 with hydroureter and 174 with dilated common bile duct, which were not visualized by conventional ultrasonography. The follow-up data of all the patients were collected to verify the results obtained by this method. Results Of the 755 patients who successfully finished the examination after normal saline retention enema (the success rate of the enema is about 98%), the nature of obstruction in 718 patients was determined (the visualizing rate is approximately 95%), including 533 with ureteral calculus, 23 with ureteral stricture, 129 with extrahepatic bile duct calculus, and 33 with common bile duct tumor. Conclusions Colons filled fully with normal saline can surely give acoustic access to the bilateral ureters and extrahepatic bile duct so as to determine the nature of obstruction of these structures when conventional transabdominal ultrasound fails. PMID:22871226

  6. Assessment: transcranial Doppler ultrasonography: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology.

    PubMed

    Sloan, M A; Alexandrov, A V; Tegeler, C H; Spencer, M P; Caplan, L R; Feldmann, E; Wechsler, L R; Newell, D W; Gomez, C R; Babikian, V L; Lefkowitz, D; Goldman, R S; Armon, C; Hsu, C Y; Goodin, D S

    2004-05-11

    To review the use of transcranial Doppler ultrasonography (TCD) and transcranial color-coded sonography (TCCS) for diagnosis. The authors searched the literature for evidence of 1) if TCD provides useful information in specific clinical settings; 2) if using this information improves clinical decision making, as reflected by improved patient outcomes; and 3) if TCD is preferable to other diagnostic tests in these clinical situations. TCD is of established value in the screening of children aged 2 to 16 years with sickle cell disease for stroke risk (Type A, Class I) and the detection and monitoring of angiographic vasospasm after spontaneous subarachnoid hemorrhage (Type A, Class I to II). TCD and TCCS provide important information and may have value for detection of intracranial steno-occlusive disease (Type B, Class II to III), vasomotor reactivity testing (Type B, Class II to III), detection of cerebral circulatory arrest/brain death (Type A, Class II), monitoring carotid endarterectomy (Type B, Class II to III), monitoring cerebral thrombolysis (Type B, Class II to III), and monitoring coronary artery bypass graft operations (Type B to C, Class II to III). Contrast-enhanced TCD/TCCS can also provide useful information in right-to-left cardiac/extracardiac shunts (Type A, Class II), intracranial occlusive disease (Type B, Class II to IV), and hemorrhagic cerebrovascular disease (Type B, Class II to IV), although other techniques may be preferable in these settings.

  7. Four-dimensional ultrasonography of the fetal heart using color Doppler spatiotemporal image correlation.

    PubMed

    Gonçalves, Luís F; Romero, Roberto; Espinoza, Jimmy; Lee, Wesley; Treadwell, Marjorie; Chintala, Kavitha; Brandl, Helmut; Chaiworapongsa, Tinnakorn

    2004-04-01

    To describe clinical and research applications of 4-dimensional imaging of the fetal heart using color Doppler spatiotemporal image correlation. Forty-four volume data sets were acquired by color Doppler spatiotemporal image correlation. Seven subjects were examined: 4 fetuses without abnormalities, 1 fetus with ventriculomegaly and a hypoplastic cerebellum but normal cardiac anatomy, and 2 fetuses with cardiac anomalies detected by fetal echocardiography (1 case of a ventricular septal defect associated with trisomy 21 and 1 case of a double-inlet right ventricle with a 46,XX karyotype). The median gestational age at the time of examination was 21 3/7 weeks (range, 19 5/7-34 0/7 weeks). Volume data sets were reviewed offline by multiplanar display and volume-rendering methods. Representative images and online video clips illustrating the diagnostic potential of this technology are presented. Color Doppler spatiotemporal image correlation allowed multiplanar visualization of ventricular septal defects, multiplanar display and volume rendering of tricuspid regurgitation, volume rendering of the outflow tracts by color and power Doppler ultrasonography (both in a normal case and in a case of a double-inlet right ventricle with a double-outlet right ventricle), and visualization of venous streams at the level of the foramen ovale. Color Doppler spatiotemporal image correlation has the potential to simplify visualization of the outflow tracts and improve the evaluation of the location and extent of ventricular septal defects. Other applications include 3-dimensional evaluation of regurgitation jets and venous streams at the level of the foramen ovale.

  8. Should anorectal ultrasonography be included as a diagnostic tool for chronic anal pain?

    PubMed

    García-Montes, M J; Argüelles-Arias, Federico; Jiménez-Contreras, S; Sánchez-Gey, S; Pellicer-Bautista, F; Herrerías-Gutiérrez, J M

    2010-01-01

    To assess the efficiency of endorectal ultrasound (ERUS) in the study of chronic idiopathic anal pain (CIAP). This is a prospective and descriptive study in which 40 patients, 18 men and 22 women with an average of 47 years, were included. They had chronic anal pain of at least 3 months duration. A complete colonoscopy was performed in all patients, which found no abnormalities to explain clinical symptoms. Patients with anal fissure and internal hemorrhoids of any degree, perianal suppurative processes, and pelvic surgery were excluded from the study. An ALOKA ProSound SSD-4000 ultrasound console attached to a multifrequency radial transductor ASU-67 (7.5 and 10 MHz) was used. One patient could not tolerate the examination. In 8 patients (20% of cases) alterations were detected during ultrasonography: in 4 patients (10% of the cases; 1 man and 3 women) internal anal sphincter (IAS) hypertrophy, and in 5 patients (4 women and 1 man) a torn sphincter complex. A tear in the upper IAS canal and hypertrophy of the middle anal canal were observed in one patient (1 woman). ERUS is a simple, economic and useful test to study anorectal pathologies. Although in most studied cases no damage to the anal canal or rectal wall was detected, in a considerable number of patients we observed a thickening of the IAS, a probable cause of anal pain. Therefore, we understand that ERUS should be included in the study of CIAP.

  9. LIVER ULTRASONOGRAPHY IN DOLPHINS: USE OF ULTRASONOGRAPHY TO ESTABLISH A TECHNIQUE FOR HEPATOBILIARY IMAGING AND TO EVALUATE METABOLIC DISEASE-ASSOCIATED LIVER CHANGES IN BOTTLENOSE DOLPHINS (TURSIOPS TRUNCATUS).

    PubMed

    Seitz, Kelsey E; Smith, Cynthia R; Marks, Stanley L; Venn-Watson, Stephanie K; Ivančić, Marina

    2016-12-01

    The objective of this study was to establish a comprehensive technique for ultrasound examination of the dolphin hepatobiliary system and apply this technique to 30 dolphins to determine what, if any, sonographic changes are associated with blood-based indicators of metabolic syndrome (insulin greater than 14 μIU/ml or glucose greater than 112 mg/dl) and iron overload (transferrin saturation greater than 65%). A prospective study of individuals in a cross-sectional population with and without elevated postprandial insulin levels was performed. Twenty-nine bottlenose dolphins ( Tursiops truncatus ) in a managed collection were included in the final data analysis. An in-water ultrasound technique was developed that included detailed analysis of the liver and pancreas. Dolphins with hyperinsulinemia concentrations had larger livers compared with dolphins with nonelevated concentrations. Using stepwise, multivariate regression including blood-based indicators of metabolic syndrome in dolphins, glucose was the best predictor of and had a positive linear association with liver size (P = 0.007, R 2 = 0.24). Bottlenose dolphins are susceptible to metabolic syndrome and associated complications that affect the liver, including fatty liver disease and iron overload. This study facilitated the establishment of a technique for a rapid, diagnostic, and noninvasive ultrasonographic evaluation of the dolphin liver. In addition, the study identified ultrasound-detectable hepatic changes associated primarily with elevated glucose concentration in dolphins. Future investigations will strive to detail the pathophysiological mechanisms for these changes.

  10. Laparoscopic management and its outcomes in cases with nonpalpable testis.

    PubMed

    Erdoğan, Cankat; Bahadır, Berktuğ; Taşkınlar, Hakan; Naycı, Ali

    2017-06-01

    Diagnostic laparoscopy is the gold standard in the algorithm of nonpalpable testis. Testicular tissue is examined and treatment is planned accordingly. In this study we reviewed the place of diagnostic laparoscopy, and evaluated the results and effectiveness of laparoscopy in the diagnosis and management of nonpalpable testis. Children who had diagnostic laparoscopy for nonpalpable testes were included in the study. Physical examination results, ultrasonography (USG) reports, age at surgery, laparoscopic and inguinal exploration findings, surgical procedures, orchiopexy results, early and late-term complications were evaluated. Follow-up visits were performed at 3-month intervals for the first, at 6-month intervals for the 2. year, then at yearly intervals. Testicular size and location was evaluated by during control examination. Overall 58 boys, and 68 testes (26 left: 44.8%; 22 right: 37.9%, and 10 bilateral: 17.2%) were included in the study. Mean age at surgery was 5.5 years (10 months-17 years). Diagnostic value of USG was 15.7%. Diagnostic laparoscopy findings were as follows: Group 1: blind-ended vessels, n=7 (10.2%); Group 2: intraabdominal testes, n=8 (11.7%); Group 3: vas and vessels entering internal ring, n=53 (77.9%). Overall 43 testes underwent orchiopexy, which were normal (n=8) or hypoplastic (n=35). Mean follow-up period was 19 months (1-12 years), and on an average 7 visits were performed (5-14). On follow-up, 5 testes were normal-sized and located in the scrotum, while 4 testes were atrophic and underwent orchiectomy. Two testes were found in the inguinal canal and redo orchiopexy was performed. Control USG revealed reduced testicular blood supply and volume. Laparoscopic surgery is safe and effective in the management of nonpalpable testes. In the majority, routine use of diagnostic laparoscopy in the algorithma does not confer any additional contributions in many patients.

  11. Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis.

    PubMed

    Arbault, Anaïs; Devilliers, Hervé; Laroche, Davy; Cayot, Audrey; Vabres, Pierre; Maillefert, Jean-Francis; Ornetti, Paul

    2016-10-01

    To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure. Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intra-observer and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data. Twenty-seven patients with psoriatic arthritis (age 55.0±16.2 years, disease duration 13.4±9.4 years) were included. Of these, 67% presented nail involvement on ultrasonography vs 37% on physical examination (P<0.05). Reliability was good (ICC and weighted kappa>0.75) for the seven quantitative parameters, except for synovitis of the DIP joint in B mode. The synovitis of the DIP joint revealed by ultrasonography correlated with the total number of clinical synovitis and Doppler US of the nail (matrix and bed). Doppler US of the matrix correlated with VAS pain but not with the ASDAS-CRP or with clinical enthesitis. No significant correlation was found with US nail thickness. The feasibility and reliability of ultrasonography of the nail in psoriatic arthritis appear to be satisfactory. Among the eight parameters evaluated, power Doppler of the matrix which correlated with local inflammation (DIP joint and bed) and with VAS pain could become an interesting outcome measure, provided that it is also sensitive to change. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  12. Creation and Validation of a Simulator for Neonatal Brain Ultrasonography: A Pilot Study.

    PubMed

    Tsai, Andy; Barnewolt, Carol E; Prahbu, Sanjay P; Yonekura, Reimi; Hosmer, Andrew; Schulz, Noah E; Weinstock, Peter H

    2017-01-01

    Historically, skills training in performing brain ultrasonography has been limited to hours of scanning infants for lack of adequate synthetic models or alternatives. The aim of this study was to create a simulator and determine its utility as an educational tool in teaching the skills that can be used in performing brain ultrasonography on infants. A brain ultrasonography simulator was created using a combination of multi-modality imaging, three-dimensional printing, material and acoustic engineering, and sculpting and molding. Radiology residents participated prior to their pediatric rotation. The study included (1) an initial questionnaire and resident creation of three coronal images using the simulator; (2) brain ultrasonography lecture; (3) hands-on simulator practice; and (4) a follow-up questionnaire and re-creation of the same three coronal images on the simulator. A blinded radiologist scored the quality of the pre- and post-training images using metrics including symmetry of the images and inclusion of predetermined landmarks. Wilcoxon rank-sum test was used to compare pre- and post-training questionnaire rankings and image quality scores. Ten residents participated in the study. Analysis of pre- and post-training rankings showed improvements in technical knowledge and confidence, and reduction in anxiety in performing brain ultrasonography. Objective measures of image quality likewise improved. Mean reported value score for simulator training was high across participants who reported perceived improvements in scanning skills and enjoyment from simulator use, with interest in additional practice on the simulator and recommendations for its use. This pilot study supports the use of a simulator in teaching radiology residents the skills that can be used to perform brain ultrasonography. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  13. Economic analysis of bedside ultrasonography (US) implementation in an Internal Medicine department.

    PubMed

    Testa, Americo; Francesconi, Andrea; Giannuzzi, Rosangela; Berardi, Silvia; Sbraccia, Paolo

    2015-12-01

    The economic crisis, the growing healthcare demand, and Defensive Medicine wastefulness, strongly recommend the restructuring of the entire medical network. New health technology, such as bedside ultrasonography, might successfully integrate the clinical approach optimizing the use of limited resources, especially in a person-oriented vision of medicine. Bedside ultrasonography is a safe and reliable technique, with worldwide expanding employment in various clinical settings, being considered as "the stethoscope of the 21st century". However, at present, bedside ultrasonography lacks economic analysis. We performed a Cost-Benefit Analysis "ex ante", with a break-even point computing, of bedside ultrasonography implementation in an Internal Medicine department in the mid-term. Number and kind estimation of bedside ultrasonographic studies were obtained by a retrospective study, whose data results were applied to the next 3-year period (foresight study). All 1980 foreseen bedside examinations, with prevailing multiorgan ultrasonographic studies, were considered to calculate direct and indirect costs, while specific and generic revenues were considered only after the first semester. Physician professional training, equipment purchase and working time represented the main fixed and variable cost items. DRG increase/appropriateness, hospitalization stay shortening and reduction of traditional ultrasonography examination requests mainly impacted on calculated revenues. The break-even point, i.e. the volume of activity at which revenues exactly equal total incurred costs, was calculated to be 734 US examinations, corresponding to € 81,998 and the time considered necessary to reach it resulting 406 days. Our economic analysis clearly shows that bedside ultrasonography implementation in clinical daily management of an Internal Medicine department can produce consistent savings, or economic profit according to managerial choices (i.e., considering public or private targets), other than evident medical benefits.

  14. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    PubMed

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Ultrasonographic detection of regional lymph node metastases in patients with intermediate or thick malignant melanoma.

    PubMed

    Brountzos, Elias N; Panagiotou, Irene E; Bafaloukos, Dimitrios I; Kelekis, Dimitrios A

    2003-01-01

    Careful monitoring of regional lymph nodes and early detection of metastases in malignant melanoma patients has an impact on their survival, since it may permit beneficial surgical therapy. Palpation is routinely used in clinical practice. The value of ultrasonography for routine follow-up of melanoma patients, still, is not generally accepted. The aim of our study was to assess the sensitivity and specificity of ultrasound and clinical examination respectively, in the detection of melanoma regional node metastases. Additionally, we evaluated whether early detection of metastases improved overall survival. One hundred and forty-eight melanoma patients with an intermediate or thick primary lesion were followed between January 1997 and May 2001. Clinical examination and concomitant regional lymph node ultrasonography were performed, every 3-4 months. If suspicious findings were identified, regional lymph node dissection was undertaken. Forty-four from the initial 148 patients relapsed with regional lymph nodal metastases. In 11 patients (25%) palpation failed to reveal the disease and metastases were depicted only by ultrasonography. In only 1 patient ultrasonography was false-negative. The sensitivity and specificity of palpation were 72.7 and 97% respectively, while those of ultrasonography were 97.7 (p<0.001) and 98% respectively. Ultrasonography was more sensitive in detecting lymph node metastases in the axilla (100%) and the groin (93.3%). When overall survival of patients presenting with local-regional recurrence was calculated--depending on the number of involved lymph nodes--a survival benefit (p<0.05) was found for patients with only one lymph node metastasis. In conclusion, ultrasonography is superior to clinical examination in the early detection of regional lymph node metastases from an intermediate or thick malignant melanoma and should be a part of those patients' surveillance.

  16. Point-of-Care Ultrasonography to Assess Portal Vein Pulsatility and the Effect of Inhaled Milrinone and Epoprostenol in Severe Right Ventricular Failure: A Report of 2 Cases.

    PubMed

    Tremblay, Jan-Alexis; Beaubien-Souligny, William; Elmi-Sarabi, Mahsa; Desjardins, Georges; Denault, André Y

    2017-10-15

    This article describes 2 patients with severe acute right ventricular failure causing circulatory shock. Portal vein pulsatility assessed by bedside ultrasonography suggested clinically relevant venous congestion. Management included cardiac preload reduction and combined inhalation of milrinone and epoprostenol to reduce right ventricular afterload. Portal vein ultrasonography may be useful in assessing right ventricular function in the acutely ill patient.

  17. Changes in ultrasonography indicators of abnormally invasive placenta during pregnancy.

    PubMed

    Calì, Giuseppe; Timor-Trisch, Ilan E; Palacios-Jaraquemada, Josè; Monteaugudo, Ana; Forlani, Francesco; Minneci, Gabriella; Foti, Francesca; Buca, Danilo; Familiari, Alessandra; Scambia, Giovanni; Liberati, Marco; D'Antonio, Francesco

    2018-03-01

    To ascertain whether the prevalence of ultrasonography signs of abnormally invasive placenta (AIP) changes during pregnancy. The present retrospective analysis included women with a prenatal diagnosis of AIP that was confirmed at delivery between January 1, 2007, and April 30, 2017, at the Department of Obstetrics and Gynaecology, Arnas Civico Hospital, Palermo, Italy. Ultrasonography signs of AIP were recorded at four different intervals during pregnancy: early first (6-9 weeks), first (11-14 weeks), second (15-24 weeks), and third trimester (25-36 weeks). There were 105 pregnancies included. Low implantation of the gestational sac was present on all ultrasonography images from the early first trimester compared with on 23 of 83 (27.7%) images from 11-14 weeks of pregnancy. The identification of loss of the clear space, placental lacunae, bladder wall interruption, and uterovesical hypervascularity all increased (all P<0.001) from the early first trimester onwards; these could all be identified in a majority of patients at 11-14 weeks of pregnancy. The prevalence of ultrasonography signs suggestive of AIP varied throughout pregnancy. During the early first trimester, indicators of AIP were similar to those of a cesarean scar pregnancy; classical ultrasonography signs of AIP were already present at 11-14 weeks of pregnancy for most patients. © 2017 International Federation of Gynecology and Obstetrics.

  18. A comparison between intrastomal 3D ultrasonography, CT scanning and findings at surgery in patients with stomal complaints.

    PubMed

    Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K

    2014-10-01

    Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.

  19. Diagnostic value of high-resolution B-mode and power-mode sonography in the follow-up of thyroid cancer.

    PubMed

    Görges, Rainer; Eising, E G; Fotescu, D; Renzing-Köhler, K; Frilling, A; Schmid, K W; Bockisch, A; Dirsch, O

    2003-02-01

    Ultrasonography is an established diagnostic modality in the follow-up of thyroid cancer. Color flow Doppler has been proposed by some authors as an additional tool for differentiating benign from malignant cervical lesions in various types of head and neck cancer. Over the last few years, a new generation of high-resolution ultrasound platforms with the "power-mode" feature has become available, that also enables the imaging of small vessel blood flow. The objective of our study was to find ways of optimizing the differentiation of benign and malignant cervical tumors in thyroid cancer follow-up by means of sonography. Hundred and twelve cervical lesions in 90 patients with thyroid cancer were evaluated by high-end ultrasonography (Sonoline Elegra, Siemens) using a small-part transducer (7.5 L 40, Siemens). B-mode sonography was performed at a frequency of 8 MHz. The Solbiati index (SI= ratio of largest to smallest diameter), configuration, echogenicity, intranodular structures, and margins were assessed. Perinodular and intranodular blood flow was evaluated by color flow Doppler (PRF 1250 Hz for conventional color flow Doppler, 868 Hz for power-mode Doppler). Possible malignancy was validated by histology, cytology, scintigraphy, and follow-up. Thirty five lesions were benign (diameter 0.4-3.0 cm) and 77 were malignant (0.4-5.4 cm). The patients were randomized into a test group and a learning group to determine the diagnostic value of various ultrasound criteria by means of statistical analysis. In the learning group, decision rules based on the dichotomized criteria were developed using a logistic regression model. Sensitivity and specificity of these decision rules were then evaluated in the test group. The presence of an echocomplex pattern or irregular hyperechoic small intranodular structures (criterion A) and the presence of an irregular diffuse intranodular blood flow (criterion B) are the best indicators of malignancy, whereas an SI >2 is highly indicative of benign changes. Color flow Doppler is a useful addition to B-mode scanning for distinguishing benign and malignant neoplasms in the follow-up of thyroid cancer. Power-mode Doppler sonography significantly improves imaging of perinodular and intranodular blood flow when compared with conventional color flow Doppler. We propose the following decision rules based on a combination of the criteria above: (A) and (B) fulfilled: malignant, if SI< or =4; (B) but not (A) fulfilled: malignant, if SI< or =3; (A) but not (B) fulfilled: malignant, if SI< or =2; neither (A) nor (B) fulfilled: malignant, if SI approximately equal to 1 (sensitivity: 90%; specificity: 82%; accuracy 88%).

  20. Subset Analysis of a Multicenter, Randomized Controlled Trial to Compare Magnifying Chromoendoscopy with Endoscopic Ultrasonography for Stage Diagnosis of Early Stage Colorectal Cancer.

    PubMed

    Yamada, Tomonori; Shimura, Takaya; Ebi, Masahide; Hirata, Yoshikazu; Nishiwaki, Hirotaka; Mizushima, Takashi; Asukai, Koki; Togawa, Shozo; Takahashi, Satoru; Joh, Takashi

    2015-01-01

    Our recent prospective study found equivalent accuracy of magnifying chromoendoscopy (MC) and endoscopic ultrasonography (EUS) for diagnosing the invasion depth of colorectal cancer (CRC); however, whether these tools show diagnostic differences in categories such as tumor size and morphology remains unclear. Hence, we conducted detailed subset analysis of the prospective data. In this multicenter, prospective, comparative trial, a total of 70 patients with early, flat CRC were enrolled from February 2011 to December 2012, and the results of 66 lesions were finally analyzed. Patients were randomly allocated to primary MC followed by EUS or to primary EUS followed by MC. Diagnoses of invasion depth by each tool were divided into intramucosal to slight submucosal invasion (invasion depth <1000 μm) and deep submucosal invasion (invasion depth ≥1000 μm), and then compared with the final pathological diagnosis by an independent pathologist blinded to clinical data. To standardize diagnoses among examiners, this trial was started after achievement of a mean κ value of ≥0.6 which was calculated from the average of κ values between each pair of participating endoscopists. Both MC and EUS showed similar diagnostic outcomes, with no significant differences in prediction of invasion depth in subset analyses according to tumor size, location, and morphology. Lesions that were consistently diagnosed as Tis/T1-SMS or ≥T1-SMD with both tools revealed accuracy of 76-78%. Accuracy was low in borderline lesions with irregular pit pattern in MC and distorted findings of the third layer in EUS (MC, 58.5%; EUS, 50.0%). MC and EUS showed the same limited accuracy for predicting invasion depth in all categories of early CRC. Since the irregular pit pattern in MC, distorted findings to the third layer in EUS and inconsistent diagnosis between both tools were associated with low accuracy, further refinements or even novel methods are still needed for such lesions. University hospital Medical Information Network Clinical Trials Registry UMIN 000005085.

  1. Effectiveness of digital infrared thermal imaging in detecting lower extremity deep venous thrombosis.

    PubMed

    Deng, Fangge; Tang, Qing; Zeng, Guangqiao; Wu, Hua; Zhang, Nuofu; Zhong, Nanshan

    2015-05-01

    The authors aimed to determine the effectiveness of infrared thermal imaging (IRTI) as a novel, noninvasive technique in adjunctive diagnostic screening for lower limb deep venous thrombosis (DVT). The authors used an infrared thermal imaging sensor to examine the lower limbs of 64 DVT patients and 64 healthy volunteers. The DVT patients had been definitively diagnosed with either Doppler vascular compression ultrasonography or angiography. The mean area temperature (T_area) and mean linear temperature (T_line) in the region of interest were determined with infrared thermal imaging. Images were evaluated with qualitative pseudocolor analysis to verify specific color-temperature responses and with quantitative temperature analysis. Differences in T_area and T_line between the DVT limb and the nonaffected limb in each DVT patient and temperature differences (TDs) in T_area (TDarea) and T_line (TDline) between DVT patients and non-DVT volunteers were compared. Qualitative pseudocolor analysis revealed visible asymmetry between the DVT side and non-DVT side in the presentation and distribution characteristics (PDCs) of infrared thermal images. The DVT limbs had areas of abnormally high temperature, indicating the presence of DVT. Of the 64 confirmed DVT patients, 62 (96.88%) were positive by IRTI detection. Among these 62 IRTI-positive cases, 53 (82.81%) showed PDCs that agreed with the DVT regions detected by Doppler vascular compression ultrasonography or angiography. In nine patients (14.06%), IRTI PDCs did not definitively agree with the DVT regions established with other testing methods, but still correctly indicated the DVT-affected limb. There was a highly significant difference between DVT and non-DVT sides in DVT patients (P < 0.01). The TDarea and TDline in non-DVT volunteers ranged from 0.19 ± 0.15 °C to 0.21 °C ± 0.17 °C; those in DVT patients ranged from 0.86 °C ± 0.71 °C to 1.03 °C ± 0.79 °C (P < 0.01). Infrared thermal imaging can be effectively used in DVT detection and adjunctive diagnostic screening because of its specific infrared PDCs and TDs values.

  2. TAP Catheters Versus Intrathecal Morphine for Cesarean Section

    ClinicalTrials.gov

    2012-05-07

    Abdominal Muscles/Ultrasonography; Adult; Anesthetics, Local/Administration & Dosage; Ropivacaine/Administration & Dosage; Ropivacaine/Analogs & Derivatives; Cesarean Section; Humans; Nerve Block/Methods; Pain Measurement/Methods; Pain, Postoperative/Prevention & Control; Ultrasonography, Interventional

  3. Final-year diagnostic radiography students' perception of role models within the profession.

    PubMed

    Conway, Alinya; Lewis, Sarah; Robinson, John

    2008-01-01

    Within a clinical education setting, the value of role models and prescribed mentors can be seen as an important influence in shaping the student's future as a diagnostic radiographer. A study was undertaken to create a new understanding of how diagnostic radiography students perceive role models and professional behavior in the workforce. The study aimed to determine the impact of clinical education in determining modeling expectations, role model identification and attributes, and the integration of academic education and "hands-on" clinical practice in preparing diagnostic radiography students to enter the workplace. Thirteen final-year (third-year) diagnostic radiography students completed an hour-long interview regarding their experiences and perceptions of role models while on clinical placement. The key concepts that emerged illustrated that students gravitate toward radiographers who enjoy sharing practical experiences with students and are good communicators. Unique to diagnostic radiography, students made distinctions about the presence of role models in private versus public service delivery. This study gives insight to clinical educators in diagnostic radiography and wider allied health into how students perceive role models, interact with preceptors, and combine real-life experiences with formal learning.

  4. The intersection syndrome: Ultrasound findings and their diagnostic value

    PubMed Central

    Montechiarello, S.; Miozzi, F.; D’Ambrosio, I.; Giovagnorio, F.

    2010-01-01

    Introduction The intersection syndrome is a well-known overuse syndrome of the distal forearm. It is characterized by noninfectious, inflammatory changes involving the area of intersection of the first (abductor pollicis longus and extensor pollicis brevis) and second (extensor carpi radialis longus and extensor carpi radialis brevis) extensor compartments in the dorsoradial aspect of the distal forearm. Imaging modalities used to diagnosis this syndrome include ultrasonography (US) and magnetic resonance imaging. The purpose of this report is to describe typical US findings in the intersection syndrome and to demonstrate the diagnostic value of this approach. Materials and methods We reviewed US findings in 4 patients (mean age 40 years) referred to our staff for symptoms suggestive of the intersection syndrome (pain, swelling, erythema, and edema of the wrist). Results In all 4 cases, the US examination revealed peritendinous edema and synovial fluid within the tendon sheaths at the intersection between the first and the second dorsal extensor tendon compartments. Discussion Our experience shows that the intersection syndrome is associated with typical signs on US. This imaging modality can be considered a reliable tool for diagnosing this syndrome and may eliminate the need for other more expensive tests. PMID:23396515

  5. Diagnostic imaging of small amounts of pleural fluid: pleural effusion vs. physiologic pleural fluid.

    PubMed

    Kocijancic, Igor

    2007-12-01

    The aim of this article is to present an overview of our 10 years clinical research work and early clinical experience with small pleural effusions. Small amounts of pleural fluid are severely difficult to identify with imaging methods (chest x-rays and ultrasound). Nevertheless, it may be an important finding, sometimes leading to a definitive diagnosis of pleural carcinomatosis, infection or other pathologic condition. Chest x-rays were used for many years for the diagnosis of small pleural effusions. Lateral decubitus chest radiographs represented a gold standard for imaging of small amounts of plural fluid for more than 80 years. In the last two decades, ultrasonography of pleural space became a leading real-time method for demonstrating small pleural effusions. Furthermore, the advent of sonographic technology actually enables detection of physiologic pleural fluid in some otherwise healthy individuals. In conclusion, new definitions of the key terms in the field of diagnostic imaging of small amounts of pleural fluid seem to be justified. We suggest that the term pleural fluid should determine physiologic pleural space condition while the term pleural effusion should only be used in the cases of pleural involvement or pleural illness.

  6. Management of patients with rectus sheath hematoma: Personal experience.

    PubMed

    Buffone, Antonino; Basile, Guido; Costanzo, Mario; Veroux, Massimiliano; Terranova, Lorenza; Basile, Antonio; Okatyeva, Valeriya; Cannizzaro, Maria Teresa

    2015-07-01

    Rectus sheath hematoma (RSH) is a rare clinical entity. It can be mistaken for other intra-abdominal disorders, which can result in diagnostic and therapeutic difficulties. This study was undertaken to analyze the clinical presentation, diagnostic modalities, and management of patients affected with RSH. Between January 2008 and June 2011, eight patients (5 men and 3 women with a mean age of 53 years) with RSH were evaluated according to demographic characteristics, clinical and radiological findings, and methods of treatment. Six patients developed RSH after anticoagulant therapy; one after local trauma, and one after laparoscopic intervention. Six patients were treated nonsurgically; one patient underwent embolization of the inferior epigastric artery and one underwent ligation of the bleeding vessel. The average hospital stay was 6 days. There were no mortality or thromboembolic complications. RSH is a rare nonneoplastic entity that is usually associated with abdominal trauma and/or anticoagulant therapy. The gold standard for diagnosis is computed tomography, and ultrasonography can be used in follow-up. The treatment of choice is nonsurgical therapy because RSH is a self-limited condition. Surgical intervention should be reserved for cases with hemodynamic instability. Copyright © 2013. Published by Elsevier B.V.

  7. Hepatic Complications of Anorexia Nervosa.

    PubMed

    Rosen, Elissa; Bakshi, Neeru; Watters, Ashlie; Rosen, Hugo R; Mehler, Philip S

    2017-11-01

    Anorexia nervosa (AN) has the highest mortality rate of all psychiatric illnesses due to the widespread organ dysfunction caused by the underlying severe malnutrition. Starvation causes hepatocyte injury and death leading to a rise in aminotransferases. Malnutrition-induced hepatitis is common among individuals with AN especially as body mass index decreases. Acute liver failure associated with coagulopathy and encephalopathy can rarely occur. Liver enzymes may also less commonly increase as part of the refeeding process due to hepatic steatosis and can be distinguished from starvation hepatitis by the finding of a fatty liver on ultrasonography. Individuals with AN and starvation-induced hepatitis are at increased risk of hypoglycemia due to depleted glycogen stores and impaired gluconeogenesis. Gastroenterology and hepatology consultations are often requested when patients with AN and signs of hepatitis are hospitalized. It should be noted that additional laboratory testing, imaging, or liver biopsy all have low diagnostic yield, are costly, and potentially invasive, therefore, not generally recommended for diagnostic purposes. While the hepatitis of AN can reach severe levels, a supervised increase in caloric intake and a return to a healthy body weight often quickly lead to normalization of elevated aminotransferases caused by starvation.

  8. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses

    PubMed Central

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-01-01

    Objective: Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. Patients and Methods: A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). Results: EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). Conclusion: EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate. PMID:24949394

  9. BCG vaccination-induced suppurative lymphadenitis: four signs to pay attention to.

    PubMed

    Baek, Sang Oon; Ko, Hyo Sun; Han, Hyun Ho

    2017-12-01

    Suppurative lymphadenitis is one of the severe complication after BCG vaccination, but its diagnostic criteria and treatment guidelines have not yet been established. In this article, we describe a case of suppurative lymphadenitis caused by BCG vaccination and propose diagnostic criteria and treatment guidelines of the disease. The lymphadenitis was presented as skin involving mass and was completely extirpated. Pathological evaluation revealed a necrotising lymphadenitis, consistent with the diagnosis of BCG lymphadenitis. The patient was administered adjuvant medical treatment with anti-TB medications (Isoniazid and Rifampicin) for 3 months. At 6 months follow-up, the disease was in complete remission without complications. We recommend focus on the following four signs when diagnosing BCG lymphadenitis: (i) previous history of vaccination on the ipsilateral side of the lesion, (ii) absence of any other infection signs, (iii) absence of fever and (iv) isolated axillary or supraclavicular/cervical lymph node enlargement proven by ultrasonography or computed tomography scan. BCG vaccination-induced suppurative lymphadenitis can easily be overlooked, but prompt, accurate diagnosis followed by appropriate surgical resection should result in complete healing as in this case. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  10. Approach to patients with pulmonary embolism in a surgical intensive care unit.

    PubMed

    Grigorakos, Leonidas; Sotiriou, Evangelia; Myrianthefs, P; Michail, Anastasia; Koulendi, Despina; Zidianakis, Vasilis; Gianakopoulos, K; Baltopoulos, G

    2008-01-01

    Pulmonary embolism (PE) is a potentially life threatening disease. Clinical signs and symptoms allow the clinician to determine the pretest probability of someone having pulmonary embolism but are insufficient to diagnose or rule out the condition. This paper aims to study the clinical presentation, identify the risk factors and evaluate the diagnostic strategies and management of patients with PE. The medical files of 69 patients were searched, who were diagnosed with PE and who were admitted to the Surgical Care Unit. Dyspnea, pleuritic pain, haemoptysis, fever and cough were the most common presenting symptoms. Risk factors for PE were found in 90% of cases. D-dimers assay was elevated in all cases (100%) and the other diagnostic strategies used showed great accuracy in confirming the pretest probabilities of PE. It is of high importance that 75% of the patients had deep vein thrombosis as assessed by venous ultrasonography. Mortality due to PE was approximately 6.9%. PE can be often overlooked with hazardous consequences. Clinical evaluation in combination with spiral CT or lung scintigraphy and vein ultrasound and D-dimer level can establish the diagnosis in the majority of patients so that effective treatment to be started as soon as possible.

  11. A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation

    PubMed Central

    2013-01-01

    Background In emergency settings, verification of endotracheal tube (ETT) location is important for critically ill patients. Ignorance of oesophageal intubation can be disastrous. Many methods are used for verification of the endotracheal tube location; none are ideal. Quantitative waveform capnography is considered the standard of care for this purpose but is not always available and is expensive. Therefore, this feasibility study is conducted to compare a cheaper alternative, bedside upper airway ultrasonography to waveform capnography, for verification of endotracheal tube location after intubation. Methods This was a prospective, single-centre, observational study, conducted at the HRPB, Ipoh. It included patients who were intubated in the emergency department from 28 March 2012 to 17 August 2012. A waiver of consent had been obtained from the Medical Research Ethics Committee. Bedside upper airway ultrasonography was performed after intubation and compared to waveform capnography. Specificity, sensitivity, positive and negative predictive value and likelihood ratio are calculated. Results A sample of 107 patients were analysed, and 6 (5.6%) had oesophageal intubations. The overall accuracy of bedside upper airway ultrasonography was 98.1% (95% confidence interval (CI) 93.0% to 100.0%). The kappa value (Κ) was 0.85, indicating a very good agreement between the bedside upper airway ultrasonography and waveform capnography. Thus, bedside upper airway ultrasonography is in concordance with waveform capnography. The sensitivity, specificity, positive predictive value and negative predictive value of bedside upper airway ultrasonography were 98.0% (95% CI 93.0% to 99.8%), 100% (95% CI 54.1% to 100.0%), 100% (95% CI 96.3% to 100.0%) and 75.0% (95% CI 34.9% to 96.8%). The likelihood ratio of a positive test is infinite and the likelihood ratio of a negative test is 0.0198 (95% CI 0.005 to 0.0781). The mean confirmation time by ultrasound is 16.4 s. No adverse effects were recorded. Conclusions Our study shows that ultrasonography can replace waveform capnography in confirming ETT placement in centres without capnography. This can reduce incidence of unrecognised oesophageal intubation and prevent morbidity and mortality. Trial registration National Medical Research Register NMRR11100810230. PMID:23826756

  12. Biomechanical behavior of muscle-tendon complex during dynamic human movements.

    PubMed

    Fukashiro, Senshi; Hay, Dean C; Nagano, Akinori

    2006-05-01

    This paper reviews the research findings regarding the force and length changes of the muscle-tendon complex during dynamic human movements, especially those using ultrasonography and computer simulation. The use of ultrasonography demonstrated that the tendinous structures of the muscle-tendon complex are compliant enough to influence the biomechanical behavior (length change, shortening velocity, and so on) of fascicles substantially. It was discussed that the fascicles are a force generator rather than a work generator; the tendinous structures function not only as an energy re-distributor but also as a power amplifier, and the interaction between fascicles and tendinous structures is essential for generating higher joint power outputs during the late pushoff phase in human vertical jumping. This phenomenon could be explained based on the force-length/velocity relationships of each element (contractile and series elastic elements) in the muscle-tendon complex during movements. Through computer simulation using a Hill-type muscle-tendon complex model, the benefit of making a countermovement was examined in relation to the compliance of the muscle-tendon complex and the length ratio between the contractile and series elastic elements. Also, the integral roles of the series elastic element were simulated in a cyclic human heel-raise exercise. It was suggested that the storage and reutilization of elastic energy by the tendinous structures play an important role in enhancing work output and movement efficiency in many sorts of human movements.

  13. Influence of elevated-CRP level-related polymorphisms in non-rheumatic Caucasians on the risk of subclinical atherosclerosis and cardiovascular disease in rheumatoid arthritis.

    PubMed

    López-Mejías, Raquel; Genre, Fernanda; Remuzgo-Martínez, Sara; González-Juanatey, Carlos; Robustillo-Villarino, Montserrat; Llorca, Javier; Corrales, Alfonso; Vicente, Esther; Miranda-Filloy, José A; Magro, César; Tejera-Segura, Beatriz; Ramírez Huaranga, Marco A; Pina, Trinitario; Blanco, Ricardo; Alegre-Sancho, Juan J; Raya, Enrique; Mijares, Verónica; Ubilla, Begoña; Mínguez Sánchez, María D; Gómez-Vaquero, Carmen; Balsa, Alejandro; Pascual-Salcedo, Dora; López-Longo, Francisco J; Carreira, Patricia; González-Álvaro, Isidoro; Rodríguez-Rodríguez, Luis; Fernández-Gutiérrez, Benjamín; Ferraz-Amaro, Iván; Castañeda, Santos; Martín, Javier; González-Gay, Miguel A

    2016-08-18

    Association between elevated C-reactive protein (CRP) serum levels and subclinical atherosclerosis and cardiovascular (CV) events was described in rheumatoid arthritis (RA). CRP, HNF1A, LEPR, GCKR, NLRP3, IL1F10, PPP1R3B, ASCL1, HNF4A and SALL1 exert an influence on elevated CRP serum levels in non-rheumatic Caucasians. Consequently, we evaluated the potential role of these genes in the development of CV events and subclinical atherosclerosis in RA patients. Three tag CRP polymorphisms and HNF1A, LEPR, GCKR, NLRP3, IL1F10, PPP1R3B, ASCL1, HNF4A and SALL1 were genotyped in 2,313 Spanish patients by TaqMan. Subclinical atherosclerosis was determined in 1,298 of them by carotid ultrasonography (by assessment of carotid intima-media thickness-cIMT-and presence/absence of carotid plaques). CRP serum levels at diagnosis and at the time of carotid ultrasonography were measured in 1,662 and 1,193 patients, respectively, by immunoturbidimetry. Interestingly, a relationship between CRP and CRP serum levels at diagnosis and at the time of the carotid ultrasonography was disclosed. However, no statistically significant differences were found when CRP, HNF1A, LEPR, GCKR, NLRP3, IL1F10, PPP1R3B, ASCL1, HNF4A and SALL1 were evaluated according to the presence/absence of CV events, carotid plaques and cIMT after adjustment. Our results do not confirm an association between these genes and CV disease in RA.

  14. Detection of severe digital vasculopathy in systemic sclerosis by colour Doppler sonography is associated with digital ulcers.

    PubMed

    Lüders, Susanne; Friedrich, Stefanie; Ohrndorf, Sarah; Glimm, Anne-Marie; Burmester, Gerd-Rüdiger; Riemekasten, Gabriela; Backhaus, Marina

    2017-11-01

    Colour Doppler ultrasonography (CDUS) is very important in general vascular diagnostic procedures. Its role in determining the extent of vasculopathy in Systemic Sclerosis (SSc) needs further investigation. The aim of this study was to compare the presence of altered arteries with nailfold capillaroscopy and clinical signs of ischaemia, that is, digital ulcers or pitting scars (DU/PS). A feasible CDUS protocol is provided. Two thousand five hundred and twenty-eight arteries of the fingers, palms and wrists from 79 SSc patients (32 arteries per patient) were examined using CDUS. Furthermore, nailfold capillaroscopy, clinical and laboratory data were evaluated. Narrowed or occluded lumens were seen in 39.8% of all assessable arteries (n = 2489) and 48.9% of all proper palmar digital arteries (n = 1564) but only 15.6% (P < 0.0001) of proximal arteries (n = 924). Fingerwise analyses presented significant coincidence of pathological CDUS findings and DU/PS (P = 0.0009). Pathological CDUS findings were also associated with elevated CRP concentrations, current or past smoking with ⩾20 pack-years, male gender and present or past DU/PS. Receiver operating characteristic curve analysis (area under the curve = 0.727) suggested a cut-off value of ⩾20% pathological vessels (sensitivity: 90.7%; specificity: 47.8%) for the presence of DU/PS. An examination protocol focusing on the right-hand digits II-V (proper palmar digital arteries) revealed similar results (area under the curve = 0.751; sensitivity: 93.0%; specificity: 43.5%). CDUS of hand and finger arteries allows measurement of the extent of SSc vasculopathy, which is associated with clinical signs of chronic malperfusion. A shortened examination protocol of CDUS (right-hand digits II-V; 15 min instead of 45 min examination time) could complement vascular diagnostics in SSc. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  15. Ultrasonography and C-reactive protein can predict the outcomes of voiding cystography after the first urinary tract infection.

    PubMed

    Kido, Jun; Yoshida, Fuminori; Sakaguchi, Katsuya; Ueno, Yasushi; Yanai, Masaaki

    2015-05-01

    This study evaluated whether sex, clinical variables, laboratory variables or ultrasonography predicted the presence of vesicoureteric reflux during the first episode of urinary tract infection in paediatric patients. We also aimed to define the criteria that indicated the need for voiding cystography testing. We used voiding cystography to investigate 200 patients who experienced their first urinary tract infection at our institution between 2004 and 2013 and retrospectively analysed the data by reviewing their medical records. Sex (p = 0.001), peak blood C-reactive protein levels (p < 0.001), the duration of fever after antibiotic administration (p = 0.007) and the ultrasonography findings grade (p < 0.001) were significantly different between patients with and without vesicoureteric reflux. Grade IV-V ultrasonography findings and C-reactive protein levels of ≥80 mg/L predicted vesicoureteric reflux with a sensitivity, specificity and odds ratio of 47.8%, 87.8% and 6.59 (95% confidence interval = 3.26-13.33), respectively (p < 0.001). Voiding cystography should be performed for patients with C-reactive protein levels of ≥80 mg/L and grade IV-V ultrasonography findings, but is not necessary in patients with C-reactive protein levels of <80 mg/L and grade I-III ultrasonography findings. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  16. Assessment of the effect of pelvic floor exercises on pelvic floor muscle strength using ultrasonography in patients with urinary incontinence: a prospective randomized controlled trial

    PubMed Central

    Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi

    2016-01-01

    [Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were evaluated at the beginning of the study and after 12 weeks. Abdominal ultrasonography measurements in transverse and longitudinal planes, the PERFECT scheme, perineometric evaluation, the stop test, the stress test, and the pad test were used to assess pelvic floor muscle strength in all cases. [Results] After training, the PERFECT, perineometry and transabdominal ultrasonography measurements were found to be significantly improved, and the stop test and pad test results were significantly decreased in the pelvic floor muscle training group, whereas no difference was observed in the control group. There was a positive correlation between the PERFECT force measurement scale and ultrasonography force measurement scale before and after the intervention in the control and pelvic floor muscle training groups (r=0.632 and r=0.642, respectively). [Conclusion] Ultrasonography can be used as a noninvasive method to identify the change in pelvic floor muscle strength with exercise training. PMID:27065519

  17. Botulinum toxin type A injection into the gastrocnemius muscle for spastic equinus in adults with stroke: a randomized controlled trial comparing manual needle placement, electrical stimulation and ultrasonography-guided injection techniques.

    PubMed

    Picelli, Alessandro; Tamburin, Stefano; Bonetti, Paola; Fontana, Carla; Barausse, Martina; Dambruoso, Francesca; Gajofatto, Francesca; Santilli, Valter; Smania, Nicola

    2012-11-01

    The aim of this study was to compare the clinical outcomes of manual needle placement, electrical stimulation, and ultrasonography-guided techniques for botulinum toxin injection into the gastrocnemius of adults with spastic equinus after stroke. After randomization into three groups, each patient received the same dose of botulinum toxin type A into the lateral and medial head of the gastrocnemius muscle (OnabotulinumtoxinA, 100U per head) of the affected leg. The manual needle placement group (n = 15) underwent injections using anatomic landmarks and palpation; the electrical stimulation group (n = 15) received injections with electrical stimulation guidance; and the ultrasonography group (n = 17) was injected under sonographic guidance. The modified Ashworth scale, the Tardieu scale, and the ankle passive range of motion were measured at baseline and 1 mo after injection. Nonparametric statistical analysis was used. One month after injection, the modified Ashworth scale improved better in the ultrasonography group than in the manual needle placement group (P = 0.008). The ankle passive range of motion improved better in the ultrasonography group than in the electrical stimulation (P = 0.004) and manual needle placement (P < 0.001) groups. No difference was found between groups for the Tardieu scale. Ultrasonography-guided injection technique could improve the clinical outcome of botulinum toxin injections into the gastrocnemius of adults with spastic equinus.

  18. Accuracy of ultrasonography and magnetic resonance imaging in the diagnosis of placenta accreta.

    PubMed

    Riteau, Anne-Sophie; Tassin, Mikael; Chambon, Guillemette; Le Vaillant, Claudine; de Laveaucoupet, Jocelyne; Quéré, Marie-Pierre; Joubert, Madeleine; Prevot, Sophie; Philippe, Henri-Jean; Benachi, Alexandra

    2014-01-01

    To evaluate the accuracy of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of placenta accreta and to define the most relevant specific ultrasound and MRI features that may predict placental invasion. This study was approved by the institutional review board of the French College of Obstetricians and Gynecologists. We retrospectively reviewed the medical records of all patients referred for suspected placenta accreta to two university hospitals from 01/2001 to 05/2012. Our study population included 42 pregnant women who had been investigated by both ultrasonography and MRI. Ultrasound images and MRI were blindly reassessed for each case by 2 raters in order to score features that predict abnormal placental invasion. Sensitivity in the diagnosis of placenta accreta was 100% with ultrasound and 76.9% for MRI (P = 0.03). Specificity was 37.5% with ultrasonography and 50% for MRI (P = 0.6). The features of greatest sensitivity on ultrasonography were intraplacental lacunae and loss of the normal retroplacental clear space. Increased vascularization in the uterine serosa-bladder wall interface and vascularization perpendicular to the uterine wall had the best positive predictive value (92%). At MRI, uterine bulging had the best positive predictive value (85%) and its combination with the presence of dark intraplacental bands on T2-weighted images improved the predictive value to 90%. Ultrasound imaging is the mainstay of screening for placenta accreta. MRI appears to be complementary to ultrasonography, especially when there are few ultrasound signs.

  19. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    PubMed

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in most patients presenting with suspected rib fractures. Moreover USG requires significantly less time than radiography. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  20. Ultrasound applications in mass casualties and extreme environments.

    PubMed

    Ma, O John; Norvell, Jeffrey G; Subramanian, Srikala

    2007-05-01

    A mass-casualty incident is one in which the number of patients with injuries exceeds the available medical resources to care for them in a timely manner. In such a situation, the numerous advantages of ultrasonography make it an ideal triage tool for helping clinicians rapidly screen patients. Experiences during the 1988 Armenian earthquake and the 1999 Turkish earthquake demonstrated the proficiency of ultrasound in providing rapid clinical data to the physicians caring for the mass-casualty patients. Wireless and satellite transmission of ultrasound images also has been shown to be feasible and may be applied to mass-casualty situations. In addition, ultrasound applications have been demonstrated to aid in the diagnosis of various conditions, including pneumothorax, in the International Space Station. Ultrasound's portability, reproducibility, accuracy, and ease of use will make it an important diagnostic instrument for future space missions.

Top