Sample records for ultrasonography-guided prostate biopsy

  1. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    PubMed

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  2. MRI/US fusion-guided prostate biopsy allows for equivalent cancer detection with significantly fewer needle cores in biopsy-naive men

    PubMed Central

    Yarlagadda, Vidhush K.; Lai, Win Shun; Gordetsky, Jennifer B.; Porter, Kristin K.; Nix, Jeffrey W.; Thomas, John V.; Rais-Bahrami, Soroush

    2018-01-01

    PURPOSE We aimed to investigate the efficiency and cancer detection of magnetic resonance imaging (MRI)/ultrasonography (US) fusion-guided prostate biopsy in a cohort of biopsy-naive men compared with standard-of-care systematic extended sextant transrectal ultrasonography (TRUS)-guided biopsy. METHODS From 2014 to 2016, 72 biopsy-naive men referred for initial prostate cancer evaluation who underwent MRI of the prostate were prospectively evaluated. Retrospective review was performed on 69 patients with lesions suspicious for malignancy who underwent MRI/US fusion-guided biopsy in addition to systematic extended sextant biopsy. Biometric, imaging, and pathology data from both the MRI-targeted biopsies and systematic biopsies were analyzed and compared. RESULTS There were no significant differences in overall prostate cancer detection when comparing MRI-targeted biopsies to standard systematic biopsies (P = 0.39). Furthermore, there were no significant differences in the distribution of severity of cancers based on grade groups in cases with cancer detection (P = 0.68). However, significantly fewer needle cores were taken during the MRI/US fusion-guided biopsy compared with systematic biopsy (63% less cores sampled, P < 0.001) CONCLUSION In biopsy-naive men, MRI/US fusion-guided prostate biopsy offers equal prostate cancer detection compared with systematic TRUS-guided biopsy with significantly fewer tissue cores using the targeted technique. This approach can potentially reduce morbidity in the future if used instead of systematic biopsy without sacrificing the ability to detect prostate cancer, particularly in cases with higher grade disease. PMID:29770762

  3. Transrectal ultrasonography-guided biopsy does not reliably identify dominant cancer location in men with low-risk prostate cancer.

    PubMed

    Washington, Samuel L; Bonham, Michael; Whitson, Jared M; Cowan, Janet E; Carroll, Peter R

    2012-07-01

    Study Type - Diagnostic (exploratory cohort) Level of Evidence 2b What's known on the subject? and What does the study add? The widespread use of serum PSA testing followed by TRUS-guided biopsy have resulted in profound prostate cancer stage migration with many patients presenting with focal rather than multifocal disease. There is increasing interest in the use of focal rather than whole-gland treatment. However, current biopsy schemes may still miss cancer or, even when cancer is identified, its extent or grade might not be accurately characterized. In order for focal therapy to be effective, the area of highest tumour volume and/or grade needs to localized accurately. The aim of this study was to assess how well biopsy, as currently performed, locates the focus of highest prostate cancer volume and/or grade. To evaluate the ability of transrectal ultrasonography (TRUS)-guided extended core biopsy to identify the dominant tumour accurately in men with early stage prostate cancer. Patients with early stage, low-risk prostate cancer who subsequently underwent radical prostatectomy (RP) and had complete surgical specimens were identified. Re-review was performed by a single uropathologist using ImageJ software to identify tumour location, dominant grade (DG) and dominant volume (DV). Pathology findings were then compared with biopsy results. A total of 51 men with early stage, low-risk prostate cancer, who had undergone RP, had complete specimens for review and a median of 15 biopsy cores taken for diagnosis and grading. Sixteen men had a single diagnostic biopsy, 21 had one repeat biopsy, and 14 had two or more repeat biopsies. Compared with surgical findings, biopsy correctly identified the sextant with the largest tumour volume in 55% (95% CI 0.5-0.6) of specimens and the highest grade in 37% (95 CI 0.3-0.5). No demographic or clinical factors were significantly associated with identification of DG. Interval between last biopsy and RP, total tissue length taken

  4. Ten-core versus 16-core transrectal ultrasonography guided prostate biopsy for detection of prostatic carcinoma: a prospective comparative study in Indian population

    PubMed Central

    Prakash, V. Surya; Mohan, G. Chandra; Krishnaiah, S. Venkata; Vijaykumar, V.; Babu, G. Ramesh; Reddy, G. Vijaya Bhaskar; Mahaboob, V. S.

    2013-01-01

    Purpose: To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Methods: Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Results: Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). Conclusions: The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients. PMID:24392441

  5. Ten-core versus 16-core transrectal ultrasonography guided prostate biopsy for detection of prostatic carcinoma: a prospective comparative study in Indian population.

    PubMed

    Prakash, V Surya; Mohan, G Chandra; Krishnaiah, S Venkata; Vijaykumar, V; Babu, G Ramesh; Reddy, G Vijaya Bhaskar; Mahaboob, V S

    2013-01-01

    To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients.

  6. Comparison of the complications of traditional 12 cores transrectal prostate biopsy with image fusion guided transperineal prostate biopsy.

    PubMed

    Huang, Haifeng; Wang, Wei; Lin, Tingsheng; Zhang, Qing; Zhao, Xiaozhi; Lian, Huibo; Guo, Hongqian

    2016-11-17

    To compare the complications of traditional transrectal (TR) prostate biopsy and image fusion guided transperineal (TP) prostate biopsy in our center. Two hundred and fourty-two patients who underwent prostate biopsy from August 2014 to January 2015were reviewed. Among them, 144 patients underwent systematic 12-core transrectal ultrasonography (TRUS) guided prostate biopsy (TR approach) while 98 patients underwent free-hand transperineal targeted biopsy with TRUS and multi-parameter magnetic resonance imaging (mpMRI) fusion images (TP approach). The complications of the two groups were presented and a simple statistical analysis was performed to compare the two groups. The cohort of our study include242 patients, including 144 patients underwent TR biopsies while 98 patients underwentTP biopsies. There was no significant difference of major complications, including sepsis, bleeding and other complication requiring admissionbetween the two groups (P > 0.05). The incidence rate of infection and rectal bleeding in TR was much higher than TP (p < 0.05), but the incidence rate of perineal swelling in TP was much higher than TR (p < 0.05). There were no significant differences of minor complications including hematuria, lower urinary tract symptoms (LUTS), dysuria, and acuteurinary retention between the two groups (p > 0.05). The present study supports the safety of both techniques. Free-handTP targeted prostate biopsy with real-time fusion imaging of mpMRI and TR ultrasound is a good approach for prostate biopsy.

  7. A Prospective Randomized Trial of Two Different Prostate Biopsy Schemes

    ClinicalTrials.gov

    2016-07-03

    Prostate Cancer; Local Anesthesia; Prostate-Specific Antigen/Blood; Biopsy/Methods; Image-guided Biopsy/Methods; Prostatic Neoplasms/Diagnosis; Prostate/Pathology; Prospective Studies; Humans; Male; Ultrasonography, Interventional/Methods

  8. Targeted vs systematic robot-assisted transperineal magnetic resonance imaging-transrectal ultrasonography fusion prostate biopsy.

    PubMed

    Mischinger, Johannes; Kaufmann, Sascha; Russo, Giorgio I; Harland, Niklas; Rausch, Steffen; Amend, Bastian; Scharpf, Marcus; Loewe, Lorenz; Todenhoefer, Tilman; Notohamiprodjo, Mike; Nikolaou, Konstantin; Stenzl, Arnulf; Bedke, Jens; Kruck, Stephan

    2018-05-01

    To evaluate the performance of transperineal robot-assisted (RA) targeted (TB) and systematic (SB) prostate biopsy in primary and repeat biopsy settings. Patients underwent RA biopsy between 2014 and 2016. Before RA-TB, multiparametric magnetic resonance imaging (mpMRI) was performed. Prostate lesions were scored (Prostate Imaging, Reporting and Data System, version 2) and used for RA-TB planning. In addition, RA-SB was performed. Available, whole-gland pathology was analysed. In all, 130 patients were biopsy naive and 72 had had a previous negative transrectal ultrasonography-guided biopsy. In total, 202 patients had suspicious mpMRI lesions. Clinically significant prostate cancer was found in 85% of all prostate cancer cases (n = 123). Total and clinically significant prostate cancer detection rates for RA-TB vs RA-SB were not significantly different at 77% vs 84% and 80% vs 82%, respectively. RA-TB demonstrated a better sampling performance compared to RA-SB (26.4% vs 13.9%; P < 0.001). Transperineal RA-TB and -SB showed similar clinically significant prostate cancer detection rates in primary and repeat biopsy settings. However, RA-TB offered a 50% reduction in biopsy cores. Omitting RA-SB is associated with a significant risk of missing clinically significant prostate cancer. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  9. Reduction in hospital admissions with the addition of prophylactic intramuscular ceftriaxone before transrectal ultrasonography-guided prostate biopsies.

    PubMed

    Luong, Benjamin; Danforth, Teresa; Visnjevac, Ognjen; Suraf, Margaret; Duff, Michael; Chevli, K Kent

    2015-03-01

    To evaluate the hospitalization rates in 2 pre-prostate biopsy antibiotic protocols. Two prebiopsy protocols were compared. CiproAlone required ciprofloxacin 500 mg twice daily starting 1 day before biopsy and continuing for 3 days after biopsy (4 days total). Diabetic patients were prescribed ciprofloxacin for 4 days after biopsy. CiproCeft required 1 dose of oral ciprofloxacin 500 mg 1 hour before the biopsy and ceftriaxone 1 g intramuscular at the time of the biopsy. Hospitalization rates between the CiproAlone vs CiproCeft protocols were examined. A total of 4134 biopsies were identified-2093 in the CiproAlone cohort and 2041 in the CiproCeft cohort. The post-prostate biopsy infection hospitalization rate was 0.6% (14 patients) in the CiproAlone group vs 0.0% (0 patients) in the CiproCeft group (P <.0001). Of the patients hospitalized, 12 fit systemic inflammatory response syndrome (SIRS) criteria. Eight of 14 hospitalized patients fit the sepsis (SIRS and source of infection) criteria. Positive cultures (urine and/or blood) resulted from 71% (n = 10) of hospitalized patients. Antibiotic resistance was analyzed. Diabetes mellitus was associated with hospitalization after prostate biopsy (P = .01) in our population, but there was no difference between the 2 groups in the rates of diabetes mellitus (P = .46). Patient age, prostate-specific antigen level, number of biopsy cores obtained, race, and previous antibiotics exposure were not found to be independent predictors of post-transrectal ultrasonography biopsy hospitalization for infection using a multivariate regression analysis. A prophylactic prebiopsy protocol including 2 classes of antibiotics, single-dose ciprofloxacin, and single-dose intramuscular ceftriaxone reduced post-transrectal ultrasonography biopsy rates of hospitalizations compared to oral ciprofloxacin alone. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    PubMed

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; P<0.001). The use of risk assessment with MRI before biopsy and MRI-targeted biopsy was superior to

  11. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a

  12. Infection after transrectal ultrasonography-guided prostate biopsy: increased relative risks after recent international travel or antibiotic use.

    PubMed

    Patel, Uday; Dasgupta, Prokar; Amoroso, Peter; Challacombe, Ben; Pilcher, James; Kirby, Roger

    2012-06-01

    Study Type - Prognosis (case series) Level of Evidence 4 What's known on the subject? and What does the study add? Septicaemia is the most frequent cause of hospitalization after transtrectal prostate biopsy; fatalities have been reported and the incidence is on the rise. This study shows that men with a history of recent international travel or antibiotic use have up to four times increased risk of septicaemia and hospitalization. When they do occur, infections are usually due to multi-resistant E coli and additional care, e.g. delay before biopsy, different antibiotic prophylaxis or transperineal biopsy, should be considered in these cases. OBJECTIVE • To study the infection rate after prostate biopsy in those who have travelled overseas or used antibiotics in the 4 weeks before biopsy. PATIENTS AND METHODS • A total of 316 men with a mean (range) age of 61 (45-85) years were studied. All had undergone transrectal ultrasonography (TRUS)-guided prostate biopsy after standard antibiotic prophylaxis. • Before their biopsy the patients were risk stratified and a history of recent international travel or antibiotic use was recorded. • Those who suffered sufficiently severe infection/sepsis so as to require hospitalization were identified at the end of the study period. • The characteristics of these patients and the types of infections were explored and the relative risk (RR) of infection after recent travel or antibiotic use was calculated. RESULTS • Of the 316 men, 16 were hospitalized with infection. • The group with (n= 16) and without (n= 300) infection were equivalent in age, prostate-specific antigen level, disease status and number of biopsy cores taken. • Either recent travel or antibiotic use were independent risk factors for infection [travel: 8/16 vs 76/300; P= 0.04; RR 2.7 and antibiotic use: 4/16 vs 20/300; P= 0.025; RR 4]. There was no significant pattern in the countries visited or the type of antibiotic used. • Culture results were

  13. Cost-effectiveness of standard vs intensive antibiotic regimens for transrectal ultrasonography (TRUS)-guided prostate biopsy prophylaxis.

    PubMed

    Adibi, Mehrad; Pearle, Margaret S; Lotan, Yair

    2012-07-01

    Multiple studies have shown an increase in the hospital admission rates due to infectious complications after transrectal ultrasonography (TRUS)-guided prostate biopsy (TRUSBx), mostly related to a rise in the prevalence of fluoroquinolone-resistant organisms. As a result, multiple series have advocated the use of more intensive prophylactic antibiotic regimens to augment the effect of the widely used fluoroquinolone prophylaxis for TRUSBx. The present study compares the cost-effectiveness fluoroquinolone prophylaxis to more intensive prophylactic antibiotic regimens, which is an important consideration for any antibiotic regimen used on a wide-scale for TRUSBx prophylaxis. To compare the cost-effectiveness of fluoroquinolones vs intensive antibiotic regimens for transrectal ultrasonography (TRUS)-guided prostate biopsy (TRUSBx) prophylaxis. Risk of hospital admission for infectious complications after TRUSBx was determined from published data. The average cost of hospital admission due to post-biopsy infection was determined from patients admitted to our University hospital ≤1 week of TRUSBx. A decision tree analysis was created to compare cost-effectiveness of standard vs intensive antibiotic prophylactic regimens based on varying risk of infection, cost, and effectiveness of the intensive antibiotic regimen. Baseline assumption included cost of TRUSBx ($559), admission rate (1%), average cost of admission ($5900) and cost of standard and intensive antibiotic regimens of $1 and $33, respectively. Assuming a 50% risk reduction in admission rates with intensive antibiotics, the standard regimen was slightly less costly with average cost of $619 vs $622, but was associated with twice as many infections. Sensitivity analyses found that a 1.1% risk of admission for quinolone-resistant infections or a 54% risk reduction attributed to the more intensive antibiotic regimen will result in cost-equivalence for the two regimens. Three-way sensitivity analyses showed that

  14. Possibility of transrectal photoacoustic imaging-guided biopsy for detection of prostate cancer

    NASA Astrophysics Data System (ADS)

    Ishihara, Miya; Shinchi, Masayuki; Horiguchi, Akio; Shinmoto, Hiroshi; Tsuda, Hitoshi; Irisawa, Kaku; Wada, Takatsugu; Asano, Tomohiko

    2017-03-01

    A transrectral ultrasonography (TRUS) guided prostate biopsy is mandatory for histological diagnosis in patients with an elevated serum prostate-specific antigen (PSA), but its diagnostic accuracy is not satisfactory; therefore, a considerable number of patients are forced to have an unnecessary repeated biopsy. Photoacoustic (PA) imaging has the ability to visualize the distribution of hemoglobin clearly. Thus, there is the potential to acquire different maps of small vessel networks between cancerous and normal tissue. We developed an original TRUS-type PA probe consisting of a microconvex array transducer with an optical illumination system providing coregistered PA and ultrasound images. The purpose of this study is to demonstrate the clinical possibility of a transrectral PA image. The prostate biopsy cores obtained by transrectal systemic biopsies under TRUS guidance were stained with HE staining and anti-CD34 antibodies as a marker of the endothelium of the blood vessel in order to find a pattern in the map of a small vessel network, which allows for imaging-based identification of prostate cancer. We analyzed the association of PA signal patterns, the cancer location by a magnetic resonance imaging (MRI) study, and the pathological diagnosis with CD34 stains as a prospective intervention study. In order to demonstrate the TRUS-merged-with-PA imaging guided targeted biopsy combined with a standard biopsy for capturing the clinically significant tumors, we developed a puncture needle guide attachment for the original TRUS-type PA probe.

  15. Defining the learning curve for multiparametric magnetic resonance imaging (MRI) of the prostate using MRI-transrectal ultrasonography (TRUS) fusion-guided transperineal prostate biopsies as a validation tool.

    PubMed

    Gaziev, Gabriele; Wadhwa, Karan; Barrett, Tristan; Koo, Brendan C; Gallagher, Ferdia A; Serrao, Eva; Frey, Julia; Seidenader, Jonas; Carmona, Lina; Warren, Anne; Gnanapragasam, Vincent; Doble, Andrew; Kastner, Christof

    2016-01-01

    To determine the accuracy of multiparametric magnetic resonance imaging (mpMRI) during the learning curve of radiologists using MRI targeted, transrectal ultrasonography (TRUS) guided transperineal fusion biopsy (MTTP) for validation. Prospective data on 340 men who underwent mpMRI (T2-weighted and diffusion-weighted MRI) followed by MTTP prostate biopsy, was collected according to Ginsburg Study Group and Standards for Reporting of Diagnostic Accuracy standards. MRI data were reported by two experienced radiologists and scored on a Likert scale. Biopsies were performed by consultant urologists not 'blinded' to the MRI result and men had both targeted and systematic sector biopsies, which were reviewed by a dedicated uropathologist. The cohorts were divided into groups representing five consecutive time intervals in the study. Sensitivity and specificity of positive MRI reports, prostate cancer detection by positive MRI, distribution of significant Gleason score and negative MRI with false negative for prostate cancer were calculated. Data were sequentially analysed and the learning curve was determined by comparing the first and last group. We detected a positive mpMRI in 64 patients from Group A (91%) and 52 patients from Group E (74%). The prostate cancer detection rate on mpMRI increased from 42% (27/64) in Group A to 81% (42/52) in Group E (P < 0.001). The prostate cancer detection rate by targeted biopsy increased from 27% (17/64) in Group A to 63% (33/52) in Group E (P < 0.001). The negative predictive value of MRI for significant cancer (>Gleason 3+3) was 88.9% in Group E compared with 66.6% in Group A. We demonstrate an improvement in detection of prostate cancer for MRI reporting over time, suggesting a learning curve for the technique. With an improved negative predictive value for significant cancer, decision for biopsy should be based on patient/surgeon factors and risk attributes alongside the MRI findings. © 2014 The Authors BJU International

  16. Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.

    PubMed

    Zamecnik, Patrik; Schouten, Martijn G; Krafft, Axel J; Maier, Florian; Schlemmer, Heinz-Peter; Barentsz, Jelle O; Bock, Michael; Fütterer, Jurgen J

    2014-12-01

    To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 μg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence. © RSNA, 2014.

  17. Development of a 3D ultrasound-guided prostate biopsy system

    NASA Astrophysics Data System (ADS)

    Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron

    2007-03-01

    Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.

  18. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    PubMed

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 or greater was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  19. Clinical utility of transperineal template-guided mapping biopsy of the prostate after negative magnetic resonance imaging-guided transrectal biopsy.

    PubMed

    Sivaraman, Arjun; Sanchez-Salas, Rafael; Ahmed, Hashim U; Barret, Eric; Cathala, Nathalie; Mombet, Annick; Uriburu Pizarro, Facundo; Carneiro, Arie; Doizi, Steeve; Galiano, Marc; Rozet, Francois; Prapotnich, Dominique; Cathelineau, Xavier

    2015-07-01

    We evaluated the prostate cancer detection with transperineal template-guided mapping biopsy in patients with elevated prostate-specific antigen and negative magnetic resonance imaging (MRI)-guided biopsy. Totally 75 patients underwent transperineal template-guided mapping biopsy for prior negative MRI-guided (cognitive registration) biopsy during April 2013 to August 2014. Primary objective was to report clinically significant cancer detection in this cohort of patients. Significant cancer was defined using varying thresholds of MCL or Gleason grade 3+4 or greater or both. Cancers with more than 80% of positive core length anterior to the level of urethra were termed anterior zone cancer. Secondary objective was to evaluate the potential clinical and radiological predictors for significant cancer detection. The mean age was 61.6 ± 6.5 years and median prostate-specific antigen was 10.4 ng/dl (7.9-18) with a mean MRI target size of 7.2mm (4-11). Transperineal template-guided mapping biopsy identified cancer in 36% (27/75) patients and 66.6% (18/27) of them were anterior zone cancers. The rates of detection of clinically significant and insignificant cancer according to the several definitions used range from 22.7% to 30.7% and 5.3% to 13.3%, respectively. Multivariate analysis did not identify any predictors for finding clinically significant and anterior cancers in this group of patients. Transperineal template-guided mapping biopsy appears to be an excellent biopsy protocol for downstream management following negative MRI-guided biopsy. Most of the cancers detected were predominantly anterior tumors. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    PubMed

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P < 0.001). There was also a markedly higher quantity of cancer tissue in MRI-guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P < 0.001). With respect to the tissue quantity, superiority of MRI-guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P < 0.001) and in Gleason grade 3 + 4 = 7 cancers (59.7 ± 38.0 vs 17.7 ± 18.4 mm 2 ; P < 0.001). Comparison of biopsy Gleason grades with findings in prostatectomy specimens was possible in 80 patients with MRI-guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high

  1. Target motion tracking in MRI-guided transrectal robotic prostate biopsy.

    PubMed

    Tadayyon, Hadi; Lasso, Andras; Kaushal, Aradhana; Guion, Peter; Fichtinger, Gabor

    2011-11-01

    MRI-guided prostate needle biopsy requires compensation for organ motion between target planning and needle placement. Two questions are studied and answered in this paper: 1) is rigid registration sufficient in tracking the targets with an error smaller than the clinically significant size of prostate cancer and 2) what is the effect of the number of intraoperative slices on registration accuracy and speed? we propose multislice-to-volume registration algorithms for tracking the biopsy targets within the prostate. Three orthogonal plus additional transverse intraoperative slices are acquired in the approximate center of the prostate and registered with a high-resolution target planning volume. Both rigid and deformable scenarios were implemented. Both simulated and clinical MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. average registration errors in clinical patient data were 2.6 mm for the rigid algorithm and 2.1 mm for the deformable algorithm. rigid tracking appears to be promising. Three tracking slices yield significantly high registration speed with an affordable error.

  2. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  3. Prospective randomized trial comparing magnetic resonance imaging (MRI)-guided in-bore biopsy to MRI-ultrasound fusion and transrectal ultrasound-guided prostate biopsy in patients with prior negative biopsies.

    PubMed

    Arsov, Christian; Rabenalt, Robert; Blondin, Dirk; Quentin, Michael; Hiester, Andreas; Godehardt, Erhard; Gabbert, Helmut E; Becker, Nikolaus; Antoch, Gerald; Albers, Peter; Schimmöller, Lars

    2015-10-01

    A significant proportion of prostate cancers (PCas) are missed by conventional transrectal ultrasound-guided biopsy (TRUS-GB). It remains unclear whether the combined approach using targeted magnetic resonance imaging (MRI)-ultrasound fusion-guided biopsy (FUS-GB) and systematic TRUS-GB is superior to targeted MRI-guided in-bore biopsy (IB-GB) for PCa detection. To compare PCa detection between IB-GB alone and FUS-GB + TRUS-GB in patients with at least one negative TRUS-GB and prostate-specific antigen ≥4 ng/ml. Patients were prospectively randomized after multiparametric prostate MRI to IB-GB (arm A) or FUS-GB + TRUS-GB (arm B) from November 2011 to July 2014. The study was powered at 80% to demonstrate an overall PCa detection rate of ≥60% in arm B compared to 40% in arm A. Secondary endpoints were the distribution of highest Gleason scores, the rate of detection of significant PCa (Gleason ≥7), the number of biopsy cores to detect one (significant) PCa, the positivity rate for biopsy cores, and tumor involvement per biopsy core. The study was halted after interim analysis because the primary endpoint was not met. The trial enrolled 267 patients, of whom 210 were analyzed (106 randomized to arm A and 104 to arm B). PCa detection was 37% in arm A and 39% in arm B (95% confidence interval for difference, -16% to 11%; p=0.7). Detection rates for significant PCa (29% vs 32%; p=0.7) and the highest percentage tumor involvement per biopsy core (48% vs 42%; p=0.4) were similar between the arms. The mean number of cores was 5.6 versus 17 (p<0.001). A limitation is the limited number of patients because of early cessation of accrual. This trial failed to identify an important improvement in detection rate for the combined biopsy approach over MRI-targeted biopsy alone. A prospective comparison between MRI-targeted biopsy alone and systematic TRUS-GB is justified. Our randomized study showed similar prostate cancer detection rates between targeted prostate biopsy

  4. Magnetic resonance spectroscopy-guided transperineal prostate biopsy and brachytherapy for recurrent prostate cancer.

    PubMed

    Barnes, Agnieszka Szot; Haker, Steven J; Mulkern, Robert V; So, Minna; D'Amico, Anthony V; Tempany, Clare M

    2005-12-01

    Brachytherapy targeted to the peripheral zone with magnetic resonance imaging (MRI) guidance is a prostate cancer treatment option with potentially fewer complications than other treatments. Follow-up MRI when failure is suspected is, however, difficult because of radiation-induced changes. Furthermore, MR spectroscopy (MRS) is compromised by susceptibility artifacts from radioactive seeds in the peripheral zone. We report a case in which combined MRI/MRS was useful for the detection of prostate cancer in the transitional zone in patients previously treated with MR-guided brachytherapy. We propose that MRI/MRS can help detect recurrent prostate cancer, guide prostate biopsy, and help manage salvage treatment decisions.

  5. Transperineal template-guided prostate saturation biopsies in men with suspicion of prostate cancer: a pilot study from Pakistan.

    PubMed

    Mehmood, K; Mubarak, M; Dhar, M; Rafi, M; Kinsella, J

    2017-12-01

    Traditionally, transrectal ultrasound (TRUS)-guided biopsies are done for the diagnosis of prostate cancer (PCa) in Pakistan. The transperineal template-guided saturation biopsy (TTSB) approach has been recently introduced in Pakistan and we share diagnostic yields and pathological findings of specimens taken for PCa diagnosis in men with elevated serum total prostate specific antigen (PSA) and negative TRUS-guided prostate biopsies. In all, 16 patients investigated at the Department of Urology, Sindh Institute of Urology and Transplantation (SIUT), underwent TTSB. The mean age of patients was 67.8 ± 8.8 (range: 55 - 84) years. The median PSA was 9.5 (IQR: 7.9 - 19.8) ng/ ml. The duration of symptoms before biopsy ranged from 1 month to 144 months. The prostate was enlarged with mean weight of 73.5 ± 55.5 g. Histopathology revealed PCa in 5 of 16 (31.2%) cases. The Gleason score was 6 (3+3), 7 (3+4) and 8 (4+4) in 1 case each (6.3%) and 10 (5+5) in 2 cases (12.5%). At least two cores were positive in all positive cases. None of the patients required antibiotics post-procedure. In conclusion, the TTSB technique is a promising option for patients with elevated PSA level and negative transrectal prostate biopsies for the detection of PCa in our setting.

  6. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    PubMed

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  7. [Focusing on MRI-suspected lesions in targeted transrectal prostate biopsy guided by MRI-TRUS fusion imaging for the diagnosis of prostate cancer].

    PubMed

    Qu, Hua-Wei; Liu, Hui; Cui, Zi-Lian; Jin, Xun-Bo; Zhao, Yong; Wang, Mu-Wen; Song, Wei; Zhang, Xin-Juan

    2016-09-01

    To improve the accuracy of prostate cancer (PCa) detection by focusing biopsy on the suspected lesion manifested by MRI with the total number of biopsy cores relatively unchanged. A prospective randomized analysis was performed on 262 cases of suspected PCa detected by multi-parametric MRI (mp-MRI), each with a single suspected lesion with 10 μg/L≤ PSA <20 μg/L. All the patients underwent targeted transrectal prostate biopsy guided by fusion imaging of MRI with transrectal ultrasonography (TRUS), using the 6X+6 strategy (6 cores in the suspected region and another 6 in the systematic prostate) for 134 cases and the traditional 12+2X method (12 cores in the systematic prostate and 2 in the suspected region) for the other 128. Comparisons were made between the two methods in the PCa detection rate in the cases of suspected lesion, total PCa detection rate, incidence of post-biopsy complications, and Gleason scores. Analyses were performed on the prostate imaging reporting and data system (PI-RADS) score, location, transverse section, and diameter of the suspected lesion. Both the total PCa detection rate and that in the cases of suspected lesion were significantly higher in the 6X+6 (44.8% and 37.3%) than in the 12+2X group (37.5% and 27.3%) (P<0.05). MRI showed that the suspected lesions were mostly (45%) located in the middle part of the prostate, the mean area of the transverse section was (0.48±0.11) cm2, and the mean diameter of the tumor was (8.51±2.21) mm. The results of biopsy showed that low-grade tumors (Gleason 3+3=6) accounted for 68% in the 6X+6 group and 71% in the 12+2X group. No statistically significant differences were found between the two groups in the incidence rate of post-biopsy complications. Compared with the traditional 12+2X method, for the suspected lesion manifested by mp-MRI, focusing biopsy on the suspected region with the 6X+6 strategy can achieve a higher PCa detection rate without increasing the incidence of complications.

  8. The detection and upgrade rates of prostate adenocarcinoma following transperineal template-guided prostate biopsy – a tertiary referral centre experience

    PubMed Central

    Telford, Robert; Viney, Richard; Patel, Prashant

    2016-01-01

    Introduction We aim to present transperineal template-guided prostate biopsy (template biopsy) outcomes at a tertiary referral centre. Furthermore, to identify the detection rate of prostate cancer in those with a previous negative transrectal ultrasound guided prostate biopsy and the upgrade rate of those on active surveillance for Gleason 3 + 3 = 6 prostate adenocarcinoma. Material and methods We conducted a prospective study of 200 consecutive men who underwent template biopsy over a 22-month period in a tertiary referral centre, using a standard 24 region template prostate biopsy technique. Indications and histology results, as well as complications, were recorded. Results Median age was 67 years and median PSA was 10 ng/mL. Overall detection rate was 47%. 39.5% of cases with previous negative transrectal biopsies were found to have prostate adenocarcinoma. 47.5% of cases on active surveillance for Gleason 3 + 3 = 6 prostate adenocarcinoma were upgraded. The most frequent complication was acute urinary retention at a rate of 12.5%, however, the use of a single prophylactic dose of tamsulosin was found to be beneficial, with 13 cases needed to treat to prevent one episode. Conclusions Template biopsies are safe and efficacious with an overall detection rate of 47% in the present series. Due to the high detection rate, one must consider template biopsy following one negative transrectal biopsy where there is persistent clinical suspicion. Furthermore, those considering active surveillance for Gleason 3 + 3 = 6 disease should be offered template biopsy to confirm the grade of their disease. PMID:27123325

  9. Detection of prostate cancer using magnetic resonance imaging/ultrasonography image-fusion targeted biopsy in African-American men.

    PubMed

    Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S

    2017-08-01

    To assess the diagnostic yield of targeted prostate biopsy in African-American (A-A) men using image fusion of multi-parametric magnetic resonance imaging (mpMRI) with real-time transrectal ultrasonography (US). We retrospectively analysed 661 patients (117 A-A and 544 Caucasian) who had mpMRI before biopsy and then underwent MRI/US image-fusion targeted biopsy (FTB) between October 2012 and August 2015. The mpMRIs were reported on a 5-point Likert scale of suspicion. Clinically significant prostate cancer (CSPC) was defined as biopsy Gleason score ≥7. After controlling for age, prostate-specific antigen level and prostate volume, there were no significant differences between A-A and Caucasian men in the detection rate of overall cancer (35.0% vs 34.2%, P = 0.9) and CSPC (18.8% vs 21.7%, P = 0.3) with MRI/US FTB. There were no significant differences between the races in the location of dominant lesions on mpMRI, and in the proportion of 5-point Likert scoring. In A-A men, MRI/US FTB from the grade 4-5 lesions outperformed random biopsy in the detection rate of overall cancer (70.6% vs 37.2%, P = 0.003) and CSPC (52.9% vs 12.4%, P < 0.001). MRI/US FTB outperformed random biopsy in cancer core length (5.0 vs 2.4 mm, P = 0.001), in cancer rate per core (24.9% vs 6.8%, P < 0.001), and in efficiency for detecting one patient with CSPC (mean number of cores needed 13.3 vs 81.9, P < 0.001), respectively. Our key finding confirms a lack of racial difference in the detection rate of overall prostate cancers and CSPC with MRI/US FTB between A-A and Caucasian men. MRI/US FTB detected more CSPC using fewer cores compared with random biopsy. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  10. Acute bacterial prostatitis after transrectal ultrasound-guided prostate biopsy: epidemiological, bacteria and treatment patterns from a 4-year prospective study.

    PubMed

    Campeggi, Alexandre; Ouzaid, Idir; Xylinas, Evanguelos; Lesprit, Philippe; Hoznek, Andras; Vordos, Dimitri; Abbou, Claude-Clément; Salomon, Laurent; de la Taille, Alexandre

    2014-02-01

    To evaluate the incidence, and clinical and bacterial features of iatrogenic prostatitis within 1 month after transrectal ultrasound-guided biopsy for detection of prostate cancer. From January 2006 to December 2009, 3000 patients underwent a 21-core transrectal ultrasound-guided prostate biopsy at Henri Mondor Hospital (Créteil, France) and were prospectively followed. All patients had a fluoroquinolone antimicrobial prophylaxis for 7 days. The primary study end-point was to evaluate the incidence of iatrogenic acute prostatitis within 1 month after the biopsy. The secondary end-point was to analyze the clinical and the bacterial features of the prostatitis. Overall, 20 patients of the entire study population (0.67%) had an acute bacterial prostatitis within 2.90 ± 1.77 days (range 1-7 days) after the transrectal ultrasound-guided biopsy. The groups of patients with (n = 20) and without (n = 2980) infection were similar in terms of age, prostate-specific antigen level and prostate volume. Escherichia coli was the only isolated bacteria. The subsequent tests for antibiotic susceptibility showed a 95% resistance for fluroquinolone and amoxicillin. Resistance to amoxiclav, trimethoprim-sulfamethoxazole, third generation cephalosporin and amikacin was 70%, 70%, 25% and 5% respectively. No resistance to imipenem was reported. They were all admitted for treatment without the need of intensive care unit referral. Complete recovery was achieved after 21.4 ± 7 days of antibiotic treatment. A fluroquinolone-based regimen still represents an appropriate prophylaxis protocol to minimize the risk of acute prostatitis secondary to prostate biopsy. Patients should be provided the appropriate care soon after the onset of the symptoms. An intravenous third generation cephalosporin or imipenem-based therapy seem to provide satisfying results. © 2013 The Japanese Urological Association.

  11. In-Bore 3-T MR-guided Transrectal Targeted Prostate Biopsy: Prostate Imaging Reporting and Data System Version 2–based Diagnostic Performance for Detection of Prostate Cancer

    PubMed Central

    Tan, Nelly; Lin, Wei-Chan; Khoshnoodi, Pooria; Asvadi, Nazanin H.; Yoshida, Jeffrey; Margolis, Daniel J. A.; Lu, David S. K.; Wu, Holden; Lu, David Y.; Huang, Jaioti

    2017-01-01

    Purpose To determine the diagnostic yield of in-bore 3-T magnetic resonance (MR) imaging–guided prostate biopsy and stratify performance according to Prostate Imaging Reporting and Data System (PI-RADS) versions 1 and 2. Materials and Methods This study was HIPAA compliant and institution review board approved. In-bore 3-T MR-guided prostate biopsy was performed in 134 targets in 106 men who (a) had not previously undergone prostate biopsy, (b) had prior negative biopsy findings with increased prostate-specific antigen (PSA) level, or (c) had a prior history of prostate cancer with increasing PSA level. Clinical, diagnostic 3-T MR imaging was performed with in-bore guided prostate biopsy, and pathology data were collected. The diagnostic yields of MR-guided biopsy per patient and target were analyzed, and differences between biopsy targets with negative and positive findings were determined. Results of logistic regression and areas under the curve were compared between PI-RADS versions 1 and 2. Results Prostate cancer was detected in 63 of 106 patients (59.4%) and in 72 of 134 targets (53.7%) with 3-T MR imaging. Forty-nine of 72 targets (68.0%) had clinically significant cancer (Gleason score ≥ 7). One complication occurred (urosepsis, 0.9%). Patients who had positive target findings had lower apparent diffusion coefficient values (875 × 10−6 mm2/sec vs 1111 × 10−6 mm2/sec, respectively; P < .01), smaller prostate volume (47.2 cm3 vs 75.4 cm3, respectively; P < .01), higher PSA density (0.16 vs 0.10, respectively; P < .01), and higher proportion of PI-RADS version 2 category 3–5 scores when compared with patients with negative target findings. MR targets with PI-RADS version 2 category 2, 3, 4, and 5 scores had a positive diagnostic yield of three of 23 (13.0%), six of 31 (19.4%), 39 of 50 (78.0%), and 24 of 29 (82.8%) targets, respectively. No differences were detected in areas under the curve for PI-RADS version 2 versus 1. Conclusion In-bore 3-T MR-guided

  12. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    PubMed

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  13. Reducing infectious complications after transrectal prostate needle biopsy using a disposable needle guide: is it possible?

    PubMed

    Gurbuz, Cenk; Canat, Lutfi; Atis, Gokhan; Caskurlu, Turhan

    2011-01-01

    To investigate whether the use of a disposable needle guide results in a decreased incidence of infectious complication after transrectal prostate needle biopsy (TPNB). Fifty five patients who underwent 10-core TPNB were randomized into two groups. A pre-biopsy blood and urine examination was performed in both groups. Group 1 (25 patients) underwent biopsy with disposable biopsy needle guide and Group 2 (30 patients) underwent biopsy with reusable biopsy needle guide. All patients had a blood and negative urine culture before the procedure. The patients received ciprofloxacin 500 mg twice a day beginning the day before the biopsy and continued for 3 days after. Serum C-reactive protein levels and urine and blood specimens were obtained 48 h after the biopsy. Primary endpoint of the study was to determine the effect of needle guide on the bacteriologic urinary tract infection (UTI) rate and secondary end point was to determine symptomatic UTI. The mean age of the patients was 63.46 (range 55 to 68) years. There were no significant differences regarding the prostate-specific antigen level, prostate size, existence of comorbidity in two groups before the procedure. Bacteriologic and symptomatic UTI was detected in 4% vs. 6.6% and 4% vs. 3.9% in Group 1 and 2 relatively (P > 0.05). The use of a disposable needle guide does not appear to minimize infection risk after TPNB. Large scale and randomized studies are necessary to determine the effect of disposable needle guide on infection rate after TPNB.

  14. Comparison between target magnetic resonance imaging (MRI) in-gantry and cognitively directed transperineal or transrectal-guided prostate biopsies for Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 MRI lesions.

    PubMed

    Yaxley, Anna J; Yaxley, John W; Thangasamy, Isaac A; Ballard, Emma; Pokorny, Morgan R

    2017-11-01

    To compare the detection rates of prostate cancer (PCa) in men with Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 abnormalities on 3-Tesla multiparametric (mp) magnetic resonance imaging (MRI) using in-bore MRI-guided biopsy compared with cognitively directed transperineal (cTP) biopsy and transrectal ultrasonography (cTRUS) biopsy. This was a retrospective single-centre study of consecutive men attending the private practice clinic of an experienced urologist performing MRI-guided biopsy and an experienced urologist performing cTP and cTRUS biopsy techniques for PI-RADS 3-5 lesions identified on 3-Tesla mpMRI. There were 595 target mpMRI lesions from 482 men with PI-RADS 3-5 regions of interest during 483 episodes of biopsy. The abnormal mpMRI target lesion was biopsied using the MRI-guided method for 298 biopsies, the cTP method for 248 biopsies and the cTRUS method for 49 biopsies. There were no significant differences in PCa detection among the three biopsy methods in PI-RADS 3 (48.9%, 40.0% and 44.4%, respectively), PI-RADS 4 (73.2%, 81.0% and 85.0%, respectively) or PI-RADS 5 (95.2, 92.0% and 95.0%, respectively) lesions, and there was no significant difference in detection of significant PCa among the biopsy methods in PI-RADS 3 (42.2%, 30.0% and 33.3%, respectively), PI-RADS 4 (66.8%, 66.0% and 80.0%, respectively) or PI-RADS 5 (90.5%, 89.8% and 90.0%, respectively) lesions. There were also no differences in PCa or significant PCa detection based on lesion location or size among the methods. We found no significant difference in the ability to detect PCa or significant PCa using targeted MRI-guided, cTP or cTRUS biopsy methods. Identification of an abnormal area on mpMRI appears to be more important in increasing the detection of PCa than the technique used to biopsy an MRI abnormality. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  15. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    PubMed

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  16. Is periprostatic nerve block a gold standard in case of transrectal ultrasound-guided prostate biopsy?

    PubMed Central

    Kumar, Ashok; Griwan, Mahavir Singh; Singh, Santosh Kumar; Sen, Jyotsna; Pawar, D. S.

    2013-01-01

    Introduction: Controversy exists over the pain during prostate biopsy. Periprostatic nerve block (PNB) is a gold standard anesthetic technique during transrectal ultrasound (TRUS)-guided prostate biopsy. Recent studies showed that PNB alone is insufficient as analgesic. We compared the efficacy of tramadol and intraprostatic nerve block (INB) in addition to PNB. Materials and Methods: We conducted a prospective double blinded placebo controlled study at our institute in 150 consecutive patients. Patients were randomized into three groups. Group A received PNB with INB with 1% lignocaine. Group B received oral tramadol with PNB. Group C patients were administered PNB only with 1% lignocaine. Patients were asked to grade the pain level using 11 point linear visual analog scale (VAS) at the time of ultrasound probe insertion, at time of anesthesia, during biopsy, and 30 min after biopsy. Results: The study groups were comparable in demographic profile, prostate-specific antigen (PSA) levels, and prostate size. Group A recorded the minimum mean pain score of 2.66 during prostate biopsy which was significantly lower than group 3 (P < 0.001). Group B recorded significantly lower pain score at time of probe insertion and at anesthetic needle insertion than other two groups. Conclusions: PNB provides better pain control in TRUS-guided prostate biopsy but still there is need of additional analgesic in the form of tramadol or INB. Tramadol has advantage of oral intake and analgesic effect at time of probe insertion and at nerve block. Both tramadol and INB may be used in combination along with PNB. PMID:24049376

  17. In-gantry MRI guided prostate biopsy diagnosis of prostatitis and its relationship with PIRADS V.2 based score.

    PubMed

    Jyoti, Rajeev; Jina, Noel Hamesh; Haxhimolla, Hodo Z

    2017-04-01

    The recent literature has focussed predominantly on prostate cancer detection which has been revolutionized by multiparametric magnetic resonance imaging (mpMRI). Due to an overlap of features, prostatitis may mimic prostate cancer on MRI, especially in patients with chronic prostatitis. We retrospectively analysed our in-gantry MRI-guided biopsy (MRGB) results to determine incidental detection rate of prostatitis in Prostate Imaging Reporting and Data System (PIRADS) 3, 4 and 5 foci reported on diagnostic MRI of the prostate. About 137 patients underwent in-gantry MRGB for lesions with PIRADS score of 3 or above. All the biopsies were performed utilizing the dynaTRIM™ system (Invio Inc, Germany) on a three-tesla MRI scanner (Ingenia 3.0T, Philips, Netherlands) by a Radiologist and a Urologist. We biopsied 228 lesions in 137 patients. There were 55 lesions that returned positive for prostate cancer with a Gleason Score of 3 + 3 = 6 or above. There were 62 lesions that showed inflammation. The distribution of these lesions was 3 (5%) in the central zone, 32 (52%) in the transitional zone and 27 (43%) in the peripheral zone. Inflammation was found in 36 (58%) PIRADS 3 lesions, 24 (39%) PIRADS 4 lesions and 2 (3%) PIRADS 5 lesions on pre biopsy MRI evaluation. In our series, biopsies which showed inflammation had a radiological appearance on mpMRI more likely of a PIRADS 3 or 4 lesions with only 3% of PIRADS 5 biopsies showing inflammation. This would suggest that a higher PIRADS score can more reliably differentiate between prostate cancer and prostatitis. © 2016 The Royal Australian and New Zealand College of Radiologists.

  18. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    PubMed

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  19. Advantages of caudal block over intrarectal local anesthesia plus periprostatic nerve block for transrectal ultrasound guided prostate biopsy

    PubMed Central

    Wang, Na; Fu, Yaowen; Ma, Haichun; Wang, Jinguo; Gao, Yang

    2016-01-01

    Objective: To compare caudal block with intrarectal local anesthesia plus periprostatic nerve block for transrectal ultrasound guided prostate biopsy. Methods: One hundred and ninety patients scheduled for transrectal ultrasound guided prostate biopsy were randomized equally into Group-A who received caudal block (20 ml 1.2% lidocaine) and Group-B who received intrarectal local anesthesia (0.3% oxybuprocaine cream) plus periprostatic nerve block (10 ml 1% lidocaine plus 0.5% ropivacaine) before biopsy. During and after the procedure, the patients rated the level of pain/discomfort at various time points. Complications during the whole study period and the patient overall satisfaction were also evaluated. Results: More pain and discomfort was detected during periprostatic nerve block than during caudal block. Pain and discomfort was significantly lower during prostate biopsy and during the manipulation of the probe in the rectum in Group-A than in Group-B. No significant differences were detected in the pain intensity after biopsy and side effects between the two groups. Conclusions: Caudal block provides better anesthesia than periprostatic nerve block plus intrarectal local anesthesia for TRUS guided prostate biopsy without an increase of side effects. PMID:27648052

  20. Incidence of sepsis following transrectal ultrasound guided prostate biopsy at a tertiary-care medical center in Lebanon

    PubMed Central

    Shahait, Mohammed; Degheili, Jad; El-Merhi, Fadi; Tamim, Hani; Nasr, Rami

    2016-01-01

    ABSTRACT Background Urosepsis is a rare but life-threatening complication following transrectal ultrasound (TRUS) guided needle prostate biopsy. Despite the technological and pharmacological improvements, the problem of bacterial urosepsis after prostate biopsy remains. A strategy for preventing urosepsis following TRUS prostate biopsy in areas with high prevalence of resistant strains or patients presenting risk factors is lacking. Objectives The aim of this study was to assess the prevalence of urosepsis, as well its predictors, following TRUS guided needle biopsy of the prostate in a tertiary care medical center in Lebanon. Materials and Methods We carried out a retrospective study on all patients who underwent TRUS prostate biopsy at the American University of Beirut Medical Center between January 1, 2011 and June 31, 2013. Patients’ hospital charts were reviewed. Data collected included demographic information, pre-procedure disease specific information, as well as post-procedure information. Predictors of urosepsis following TRUS were assessed. Results In total, 265 patients were included in this study, where the prevalence of urosepsis following TRUS prostate biopsy was found to be 9.4%. The significant independent predictors of urosepsis were found to be: age with an OR=0.93 (95% CI: 0.88–1.00, p-value=0.03), and hypertension comorbidity with an OR=3.25 (95% CI: 1.19–8.85, p-value=0.02). Conclusion We found a high prevalence of urosepsis among patients who have undergone TRUS prostate biopsy, and identified two significant risk factors. The results of this study highlight the importance of implementing strategies for prevention of urosepsis following TRUS prostate biopsy. PMID:27136468

  1. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    PubMed

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  2. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    PubMed

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  3. [Ultrasonography of the prostate gland : From B‑image through multiparametric ultrasound to targeted biopsy].

    PubMed

    Steinkohl, F; Luger, A; Bektic, J; Aigner, F

    2017-08-01

    Prostate cancer is the most frequent cancer in men. The diagnosis is normally achieved by a systematic prostate biopsy; however, this is a randomized approach by which a substantial number of significant carcinomas go undetected. For this reason, in recent years imaging techniques have been continuously developed, which enable visualization and therefore targeted biopsies. The use of systematic biopsies is a standard procedure for the detection of prostate cancer. The quality of biopsies can be increased if the prostate is examined for the presence of suspected cancerous alterations during the biopsy. This can be carried out using multiparametric transrectral ultrasound. Multiparametric ultrasound within the framework of a targeted biopsy increases the detection rate of significant prostate carcinomas with a simultaneous decrease in detection of insignificant carcinomas; however, the diagnostic reliability and the evidence level of multiparametric transrectal ultrasound are not yet sufficiently high to be able to replace a systematic biopsy. In the hands of a well-trained examiner multiparametric transrectal ultrasound represents a good method for detection of prostate carcinomas. With the progression in technical developments of ultrasound technology, the detection rate will presumably be further increased.

  4. Clinical efficacy of transrectal ultrasound-guided prostate biopsy in men younger than 50 years old with an elevated prostate-specific antigen concentration (>4.0 ng/mL).

    PubMed

    Lu, Chin-Heng; Lin, Tzu-Ping; Shen, She Huei; Huang, Yi-Hsiu; Chung, Hsiao-Jen; Kuo, Junne-Yih; Huang, William J S; Wu, Howard H H; Chang, Yen-Hwa; Lin, Alex T L; Chen, Kuang-Kuo

    2017-07-01

    Prostate cancer (PCa) is not commonly found in men younger than 50 years of age. However, serum prostate-specific antigen (PSA) concentration has been examined more frequently at a younger age in Asia partially due to an increased awareness of prostate cancer. The purpose of our study was to investigate the efficacy and complication of PSA-triggered transrectal ultrasonography-guided prostate (TRUSP) biopsies. We retrospectively reviewed TRUSP biopsies in young men with elevated PSA concentration in Taipei Veterans General Hospital. We reviewed the cases of patients younger than 50 years of age with elevated PSA concentration (>4.0 ng/mL), who received 12 cores TRUSP biopsies at TPEVGH from January 2008-December 2013. The age, family history, digital rectal examination (DRE) results, PSA concentration, free/total PSA ratio, total prostate volume, PSA density, lower urinary tract symptoms and complications after the procedure were reviewed. The pathologic findings of TRUSP biopsy and clinical follow-up were reviewed and analyzed according to the Epstein criteria. A total of 77 patients were included and were divided into 2 groups: 1) the younger group consisted of 20 patients <40 years of age; and 2) the elder group had 57 patients who were 40-50 years of age. The overall detection rate of PCa was 11.69% (9/77), and all of the PCa cases were diagnosed in the elder group (group detection rate: 15.8%). There was a significant difference in the severity of lower urinary tract symptoms (LUTS) between these 2 groups. All PCa patients were clinically significant according to the Epstein criteria. Two patients experienced fever (2.60%) after TRUSP biopsy. From our patient cohort, it appears that no benefit was apparent for patients younger than 40 years old who received TRUSP biopsy, even with elevated PSA. However, PCa detected in men between 40 and 50 years of age were all clinically significant. Overall, our results supported current major practice guidelines which

  5. Motorized fusion guided prostate biopsy: phantom study

    NASA Astrophysics Data System (ADS)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.

    2017-03-01

    Purpose: Fusion of Magnetic Resonance Imaging (MRI) with intraoperative real-time Ultrasound (US) during prostate biopsy has significantly improved the sensitivity of transrectal ultrasound (TRUS) guided cancer detection. Currently, sweeping of the TRUS probe to build a 3D volume as part of the fusion process and the TRUS probe manipulation for needle guidance are both done manually. A motorized, joystick controlled, probe holder was custom fabricated that can potentially reduce inter-operator variability, provide standardization of needle placement, improve repeatability and uniformity of needle placement, which may have impacts upon the learning curve after clinical deployment of this emerging approach. Method: a 2DOF motorized probe holder was designed to provide translation and rotation of a triplane TRUS end firing probe for prostate biopsy. The probe holder was joystick controlled and can assist manipulation of the probe during needle insertion as well as in acquiring a smoother US 2D to 3D sweep in which the 3D US volume for fusion is built. A commercial MRI-US fusion platform was used. Three targets were specified on MR image of a commercial prostate phantom. After performing the registration, two operators performed targeting, once manually and once with the assistance of the motorized probe holder. They repeated these tasks 5 times resulting in a total of 30 targeting events. Time of completion and mechanical error i.e. distance of the target from the needle trajectory in the software user interface were measured. Repeatability in reaching a given target in a systematic and consistent way was measured using a scatter plot showing all targets in the US coordinate system. Pearson product-moment correlation coefficient (PPMCC) was used to demonstrate the probe steadiness during targeting. Results: the completion time was 25+/-17 sec, 25+/-24 sec, and 27+/-15 sec for free hand and 24+/-10 sec, 22.5+/-10 sec, and 37+/-10 sec for motorized insertion, for target

  6. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    PubMed

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  7. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    PubMed

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  8. The efficacy of duration of prophylactic antibiotics in transrectal ultrasound guided prostate biopsy.

    PubMed

    Bulut, Volkan; Şahin, Ali Feyzullah; Balaban, Yavuz; Altok, Muammer; Divrik, Rauf Taner; Zorlu, Ferruh

    2015-01-01

    We aimed to evaluate the efficacy of the duration of prophylactic antibiotic administration in patients undergoing transrectal ultrasound (TRUS) guided biopsy. A total of 367 patients undergoing a prostate biopsy between September 2007 and June 2009 was reviewed retrospectively and divided into 2 groups according to prophilaxy: oral ciprofloxacin (750 mg every 12 hours) for 3 or more days in Group-1 and single day in Group-2. Demographic characteristics of patients, symptoms, PSA values, IPSS scores, prostate sizes, pathologic results and complications were compared between the groups. The mean age of all patients was 63.92 years and the mean PSA was 13.61ng/ dL. The pre-biopsy mean IPSS score was 12.47 and mean prostate volume 52.53 mL. For 78.2% of patients the current biopsy was their first biopsy. Cancer detection rate was 24.2%. Fever was observed in 3 (1.2%) patients in Group-1 and 5 (4.0%) patients in Group-2. Local infections occurred in 2 (0.8%) and 1 (0.8%) patients respectively in Groups 1 and 2. Acute prostatitis was observed in only 1 (0.8%) patient in Group-2. None of the patients developed septicemia or other serious infection. There was no statistically significant difference in terms of fever, local infections (epididimitis, orchitis, etc.) and acute prostatitis. In a selected patient population single dose prophylaxis with ciprofloxacin can be safely administered compared to other regimens of 3 or more days. Increasing the duration of antibiotic prophylaxis does not decrease infectious complications.

  9. The effect of rectal Foley catheterization on rectal bleeding rates after transrectal ultrasound-guided prostate biopsy.

    PubMed

    Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali

    2008-09-01

    To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.

  10. The change in serum Thiol/Disulphide homeostasis after transrectal ultrasound guided prostate biopsy

    PubMed Central

    Tokgöz, Hüsnü; Taş, Selim; Giray, Özlem; Yalçınkaya, Soner; Tokgöz, Özlem; Koca, Cemile; Savaş, Murat; Erel, Özcan

    2017-01-01

    ABSTRACT Objectives The aim of this prospective clinical study was to investigate variations in a novel oxidative stress marker (thiol/disulphide homeostasis) in men who underwent transrectal ultrasound guided prostate biopsy (TRUSB). Materials and Methods A total of 22 men undergoing TRUSB of the prostate were enrolled in the study. Patients with abnormal digital rectal examination and/or total prostate specific antigen (PSA) over 4ng/mL underwent TRUSB with 12 cores. Serum samples were obtained before and just after the procedure to evaluate the possible changes in thiol/disulphide homeostasis. Mean age, total PSA and free PSA, prostate volume and histopathological data were also recorded. Results Mean age of the study population was 65.05±8.89 years. Significant decreases in native and total thiol levels were documented after the biopsy procedure. However, serum disulphide levels and disulphide/native thiol, disulphide/total thiol and native/total thiol ratios did not significantly change after TRUSB. No correlation was observed between oxidative parameters and total PSA and free PSA levels, prostate volume and histopathology of the prostate. However, mean patient age was significantly correlated with mean native and total thiol levels. Conclusion Significant decreases in serum native and total thiol levels related to the prostate biopsy procedure suggest that TRUSB causes acute oxidative stress in the human body. Since our trial is the first in the current literature to investigate these oxidative stress markers in urology practice, additional studies are warranted. PMID:28128906

  11. The change in serum Thiol/Disulphide homeostasis after transrectal ultrasound guided prostate biopsy.

    PubMed

    Tokgöz, Hüsnü; Taş, Selim; Giray, Özlem; Yalçınkaya, Soner; Tokgöz, Özlem; Koca, Cemile; Savaş, Murat; Erel, Özcan

    2017-01-01

    The aim of this prospective clinical study was to investigate variations in a novel oxidative stress marker (thiol/disulphide homeostasis) in men who underwent transrectal ultrasound guided prostate biopsy (TRUSB). A total of 22 men undergoing TRUSB of the prostate were enrolled in the study. Patients with abnormal digital rectal examination and/or total prostate specific antigen (PSA) over 4ng/mL underwent TRUSB with 12 cores. Serum samples were obtained before and just after the procedure to evaluate the possible changes in thiol/disulphide homeostasis. Mean age, total PSA and free PSA, prostate volume and histopathological data were also recorded. Mean age of the study population was 65.05±8.89 years. Significant decreases in native and total thiol levels were documented after the biopsy procedure. However, serum disulphide levels and disulphide/native thiol, disulphide/total thiol and native / total thiol ratios did not significantly change after TRUSB. No correlation was observed between oxidative parameters and total PSA and free PSA levels, prostate volume and histopathology of the prostate. However, mean patient age was significantly correlated with mean native and total thiol levels. Significant decreases in serum native and total thiol levels related to the prostate biopsy procedure suggest that TRUSB causes acute oxidative stress in the human body. Since our trial is the first in the current literature to investigate these oxidative stress markers in urology practice, additional studies are warranted. Copyright® by the International Brazilian Journal of Urology.

  12. Parametric PET/MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies

    DTIC Science & Technology

    2013-10-01

    AD_________________ Award Number: W81XWH-12-1-0597 TITLE: Parametric PET /MR Fusion Imaging to...Parametric PET /MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies...The study investigates whether fusion PET /MRI imaging with 18F-choline PET /CT and diffusion-weighted MRI can be successfully applied to target prostate

  13. Combination of prostate imaging reporting and data system (PI-RADS) score and prostate-specific antigen (PSA) density predicts biopsy outcome in prostate biopsy naïve patients.

    PubMed

    Washino, Satoshi; Okochi, Tomohisa; Saito, Kimitoshi; Konishi, Tsuzumi; Hirai, Masaru; Kobayashi, Yutaka; Miyagawa, Tomoaki

    2017-02-01

    To assess the value of the Prostate Imaging Reporting and Data System (PI-RADS) scoring system, for prostate multi-parametric magnetic resonance imaging (mpMRI) to detect prostate cancer, and classical parameters, such as prostate-specific antigen (PSA) level, prostate volume and PSA density, for predicting biopsy outcome in biopsy naïve patients who have suspected prostate cancer. Patients who underwent mpMRI at our hospital, and who had their first prostate biopsy between July 2010 and April 2014, were analysed retrospectively. The prostate biopsies were taken transperineally under transrectal ultrasonography guidance. In all, 14 cores were biopsied as a systematic biopsy in all patients. Two cognitive fusion-targeted biopsy cores were added for each lesion in patients who had suspicious or equivocal lesions on mpMRI. The PI-RADS scoring system version 2.0 (PI-RADS v2) was used to describe the MRI findings. Univariate and multivariate analyses were performed to determine significant predictors of prostate cancer and clinically significant prostate cancer. In all, 288 patients were analysed. The median patient age, PSA level, prostate volume and PSA density were 69 years, 7.5 ng/mL, 28.7 mL, and 0.26 ng/mL/mL, respectively. The biopsy results were benign, clinically insignificant, and clinically significant prostate cancer in 129 (45%), 18 (6%) and 141 (49%) patients, respectively. The multivariate analysis revealed that PI-RADS v2 score and PSA density were independent predictors for prostate cancer and clinically significant prostate cancer. When PI-RADS v2 score and PSA density were combined, a PI-RADS v2 score of ≥4 and PSA density ≥0.15 ng/mL/mL, or PI-RADS v2 score of 3 and PSA density of ≥0.30 ng/mL/mL, was associated with the highest clinically significant prostate cancer detection rates (76-97%) on the first biopsy. Of the patients in this group with negative biopsy results, 22% were subsequently diagnosed as prostate cancer. In contrast, a PI

  14. The efficacy of duration of prophylactic antibiotics in transrectal ultrasound guided prostate biopsy

    PubMed Central

    Bulut, Volkan; Şahin, Ali Feyzullah; Balaban, Yavuz; Altok, Muammer; Divrik, Rauf Taner; Zorlu, Ferruh

    2015-01-01

    ABSTRACT Introduction: We aimed to evaluate the efficacy of the duration of prophylactic antibiotic administration in patients undergoing transrectal ultrasound (TRUS) guided biopsy. Material and Methods: A total of 367 patients undergoing a prostate biopsy between September 2007 and June 2009 was reviewed retrospectively and divided into 2 groups according to prophilaxy: oral ciprofloxacin (750 mg every 12 hours) for 3 or more days in Group-1 and single day in Group-2. Demographic characteristics of patients, symptoms, PSA values, IPSS scores, prostate sizes, pathologic results and complications were compared between the groups. Results: The mean age of all patients was 63.92 years and the mean PSA was 13.61ng/ dL. The pre-biopsy mean IPSS score was 12.47 and mean prostate volume 52.53 mL. For 78.2% of patients the current biopsy was their first biopsy. Cancer detection rate was 24.2%. Fever was observed in 3 (1.2%) patients in Group-1 and 5 (4.0%) patients in Group-2. Local infections occurred in 2 (0.8%) and 1 (0.8%) patients respectively in Groups 1 and 2. Acute prostatitis was observed in only 1 (0.8%) patient in Group-2. Accepted after revision: None of the patients developed septicemia or other serious infection. There was no statistically significant difference in terms of fever, local infections (epididimitis, orchitis, etc.) and acute prostatitis. Conclusions: In a selected patient population single dose prophylaxis with ciprofloxacin can be safely administered compared to other regimens of 3 or more days. Increasing the duration of antibiotic prophylaxis does not decrease infectious complications. PMID:26689515

  15. Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis

    DTIC Science & Technology

    2012-06-01

    can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study are (1) light...which collect light scattering and auto-fluorescence from the prostate tissue, into a transrectal- ultrasound , needle - biopsy probe. In the...probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study were

  16. Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis

    DTIC Science & Technology

    2011-06-01

    integrated needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for... needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study...tissue, into a transrectal- ultrasound , needle - biopsy probe. In the development phase, documentation to obtain IRB approval for ex vivo human prostate

  17. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    NASA Astrophysics Data System (ADS)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  18. Effectiveness of stress management in patients undergoing transrectal ultrasound-guided biopsy of the prostate.

    PubMed

    Chiu, Li-Pin; Tung, Heng-Hsin; Lin, Kuan-Chia; Lai, Yu-Wei; Chiu, Yi-Chun; Chen, Saint Shiou-Sheng; Chiu, Allen W

    2016-01-01

    To assess the utilization of stress management in relieving anxiety and pain among patients who undergo transrectal ultrasound (TRUS)-guided biopsy of the prostate. Eighty-two patients admitted to a community hospital for a TRUS biopsy of the prostate participated in this case-controlled study. They were divided into an experimental group that was provided with stress management and a control group that received only routine nursing care. Stress management included music therapy and one-on-one simulation education. Before and after the TRUS biopsy, the patients' state-anxiety inventory score, pain visual analogue scale (VAS), respiratory rate, heart rate, and blood pressure were obtained. There were no differences in baseline and disease characteristics between the two groups. The VAS in both groups increased after the TRUS biopsy, but the difference in pre- and postbiopsy VAS scores was significantly lower in the experimental group (P=0.03). Patients in both groups experienced mild anxiety before and after the biopsy, but those in the experimental group displayed a significantly greater decrease in postbiopsy state-anxiety inventory score compared to the control group (P=0.02). Stress management can alleviate anxiety and pain in patients who received a TRUS biopsy of the prostate under local anesthesia.

  19. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion.

    PubMed

    Venderink, Wulphert; Govers, Tim M; de Rooij, Maarten; Fütterer, Jurgen J; Sedelaar, J P Michiel

    2017-05-01

    Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. A decision tree and Markov model were developed to compare cost-effectiveness. Literature review and expert opinion were used as input. A strategy was deemed cost-effective if the costs of gaining one quality-adjusted life year (incremental cost-effectiveness ratio) did not exceed the willingness-to-pay threshold of €80,000 (≈$85,000 in January 2017). A base case analysis was performed to compare systematic transrectal ultrasound- and image fusion-guided biopsies. Because of a lack of appropriate literature regarding the accuracy of direct in-bore MRI-guided biopsy, a threshold analysis was performed. The incremental cost-effectiveness ratio for fusion-guided biopsy compared with systematic transrectal ultrasound-guided biopsy was €1386 ($1470) per quality-adjusted life year gained, which was below the willingness-to-pay threshold and thus assumed cost-effective. If MRI findings are normal in a patient with clinically significant prostate cancer, the sensitivity of direct in-bore MRI-guided biopsy has to be at least 88.8%. If that is the case, the incremental cost-effectiveness ratio is €80,000 per quality-adjusted life year gained and thus cost-effective. Fusion-guided biopsy seems to be cost-effective compared with systematic transrectal ultrasound-guided biopsy. Future research is needed to determine whether direct in-bore MRI-guided biopsy is the best pathway; in this study a threshold was calculated at which it would be cost-effective.

  20. A fully actuated robotic assistant for MRI-guided prostate biopsy and brachytherapy

    NASA Astrophysics Data System (ADS)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2013-03-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm.

  1. [Cost analysis of ultrasound-guided transrectal needle biopsy in prostatic carcinoma].

    PubMed

    Bissoli, E; Fandella, A; La Torre, E; Faggiano, L; Anselmo, G; Frasson, F

    1998-04-01

    The literature mortality and morbidity rates from prostatic carcinoma prompt to the better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. We evaluated the overall cost of transrectal ultrasound biopsy (TRUSB) of the prostate and investigated the economic impact of the procedures currently used to diagnose prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 1996. The following cost factors were evaluated: personnel, materials, maintenance-equipment depreciation, energy consumption and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide and to consider them in the wider framework of the cost effectiveness of the strategies for the early diagnosis of prostatic cancer. The overall cost of TRUSB was Itl. 249,000, obtained by adding together the costs of: personnel (Itl. 160,000); materials (Itl. 59,000); equipment maintenance and depreciation (Itl. 12,400); energy consumption (Itl. 100); hospital overheads (Itl. 17,500). The literature review points out TRUSB as a clinically invasive tool for diagnosing prostatic carcinoma whose cost-effectiveness is debated. Cadaver studies report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, are very likely to be positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the positivity of exploration and/or transrectal ultrasound findings. Despite the strict application of all these criteria and the critical assessment of the patient's general conditions, TRUSB is indicated for 16% of the male population over 50, with obvious implications. It has been recently

  2. Multiparametric MRI followed by targeted prostate biopsy for men with suspected prostate cancer: a clinical decision analysis

    PubMed Central

    Willis, Sarah R; Ahmed, Hashim U; Moore, Caroline M; Donaldson, Ian; Emberton, Mark; Miners, Alec H; van der Meulen, Jan

    2014-01-01

    Objective To compare the diagnostic outcomes of the current approach of transrectal ultrasound (TRUS)-guided biopsy in men with suspected prostate cancer to an alternative approach using multiparametric MRI (mpMRI), followed by MRI-targeted biopsy if positive. Design Clinical decision analysis was used to synthesise data from recently emerging evidence in a format that is relevant for clinical decision making. Population A hypothetical cohort of 1000 men with suspected prostate cancer. Interventions mpMRI and, if positive, MRI-targeted biopsy compared with TRUS-guided biopsy in all men. Outcome measures We report the number of men expected to undergo a biopsy as well as the numbers of correctly identified patients with or without prostate cancer. A probabilistic sensitivity analysis was carried out using Monte Carlo simulation to explore the impact of statistical uncertainty in the diagnostic parameters. Results In 1000 men, mpMRI followed by MRI-targeted biopsy ‘clinically dominates’ TRUS-guided biopsy as it results in fewer expected biopsies (600 vs 1000), more men being correctly identified as having clinically significant cancer (320 vs 250), and fewer men being falsely identified (20 vs 50). The mpMRI-based strategy dominated TRUS-guided biopsy in 86% of the simulations in the probabilistic sensitivity analysis. Conclusions Our analysis suggests that mpMRI followed by MRI-targeted biopsy is likely to result in fewer and better biopsies than TRUS-guided biopsy. Future research in prostate cancer should focus on providing precise estimates of key diagnostic parameters. PMID:24934207

  3. Variability of transrectal ultrasound-guided prostate biopsy prophylactic measures.

    PubMed

    Hillelsohn, Joel H; Duty, Brian; Blute, Michael L; Okhunov, Zhamshid; Kashan, Mahyar; Moldwin, Robert; Ashley, Richard N

    2012-12-01

    To assess the variability of pre-prostate biopsy prophylaxis among American urologists. A survey was electronically mailed to 3355 urologists around the country. Urologists were surveyed on their antibiotic prophylaxis choice, the route and duration of antimicrobial prophylaxis. Additionally they were questioned about their knowledge of local antimicrobial resistance and if rectal enemas were routinely used. There were 679 (21%) responses to the survey. The survey revealed differences in pre-prostate biopsy prophylaxis among urologists. Ten different classes of antibiotics were used orally, 4 classes intramuscular, 5 classes intravenous, and there was also 14 different duration regimens. Despite the initiation of the 2008 American Urological Association Guidelines on this topic, there still is a lack of uniformity in prostate biopsy prophylaxis.

  4. Multicentre evaluation of targeted and systematic biopsies using magnetic resonance and ultrasound image-fusion guided transperineal prostate biopsy in patients with a previous negative biopsy.

    PubMed

    Hansen, Nienke L; Kesch, Claudia; Barrett, Tristan; Koo, Brendan; Radtke, Jan P; Bonekamp, David; Schlemmer, Heinz-Peter; Warren, Anne Y; Wieczorek, Kathrin; Hohenfellner, Markus; Kastner, Christof; Hadaschik, Boris

    2017-11-01

    To evaluate the detection rates of targeted and systematic biopsies in magnetic resonance imaging (MRI) and ultrasound (US) image-fusion transperineal prostate biopsy for patients with previous benign transrectal biopsies in two high-volume centres. A two centre prospective outcome study of 487 patients with previous benign biopsies that underwent transperineal MRI/US fusion-guided targeted and systematic saturation biopsy from 2012 to 2015. Multiparametric MRI (mpMRI) was reported according to Prostate Imaging Reporting and Data System (PI-RADS) Version 1. Detection of Gleason score 7-10 prostate cancer on biopsy was the primary outcome. Positive (PPV) and negative (NPV) predictive values including 95% confidence intervals (95% CIs) were calculated. Detection rates of targeted and systematic biopsies were compared using McNemar's test. The median (interquartile range) PSA level was 9.0 (6.7-13.4) ng/mL. PI-RADS 3-5 mpMRI lesions were reported in 343 (70%) patients and Gleason score 7-10 prostate cancer was detected in 149 (31%). The PPV (95% CI) for detecting Gleason score 7-10 prostate cancer was 0.20 (±0.07) for PI-RADS 3, 0.32 (±0.09) for PI-RADS 4, and 0.70 (±0.08) for PI-RADS 5. The NPV (95% CI) of PI-RADS 1-2 was 0.92 (±0.04) for Gleason score 7-10 and 0.99 (±0.02) for Gleason score ≥4 + 3 cancer. Systematic biopsies alone found 125/138 (91%) Gleason score 7-10 cancers. In patients with suspicious lesions (PI-RADS 4-5) on mpMRI, systematic biopsies would not have detected 12/113 significant prostate cancers (11%), while targeted biopsies alone would have failed to diagnose 10/113 (9%). In equivocal lesions (PI-RADS 3), targeted biopsy alone would not have diagnosed 14/25 (56%) of Gleason score 7-10 cancers, whereas systematic biopsies alone would have missed 1/25 (4%). Combination with PSA density improved the area under the curve of PI-RADS from 0.822 to 0.846. In patients with high probability mpMRI lesions, the highest detection rates of Gleason

  5. [Real-time three-dimensional (4D) ultrasound-guided prostatic biopsies on a phantom. Comparative study versus 2D guidance].

    PubMed

    Long, Jean-Alexandre; Daanen, Vincent; Moreau-Gaudry, Alexandre; Troccaz, Jocelyne; Rambeaud, Jean-Jacques; Descotes, Jean-Luc

    2007-11-01

    The objective of this study was to determine the added value of real-time three-dimensional (4D) ultrasound guidance of prostatic biopsies on a prostate phantom in terms of the precision of guidance and distribution. A prostate phantom was constructed. A real-time 3D ultrasonograph connected to a transrectal 5.9 MHz volumic transducer was used. Fourteen operators performed 336 biopsies with 2D guidance then 4D guidance according to a 12-biopsy protocol. Biopsy tracts were modelled by segmentation in a 3D ultrasound volume. Specific software allowed visualization of biopsy tracts in the reference prostate and evaluated the zone biopsied. A comparative study was performed to determine the added value of 4D guidance compared to 2D guidance by evaluating the precision of entry points and target points. The distribution was evaluated by measuring the volume investigated and by a redundancy ratio of the biopsy points. The precision of the biopsy protocol was significantly improved by 4D guidance (p = 0.037). No increase of the biopsy volume and no improvement of the distribution of biopsies were observed with 4D compared to 2D guidance. The real-time 3D ultrasound-guided prostate biopsy technique on a phantom model appears to improve the precision and reproducibility of a biopsy protocol, but the distribution of biopsies does not appear to be improved.

  6. The Rectal Administration of Lignocaine Gel and Periprostatic Lignocaine Infiltration During Transrectal Ultrasound-Guided Prostate Biopsy Provides Effective Analgesia

    PubMed Central

    Siddiqui, EJ; Ali, S; Koneru, S

    2006-01-01

    INTRODUCTION Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or exclude prostate cancer. This procedure can be associated with significant discomfort, both on insertion of the ultrasound probe as well as on taking the biopsy. We evaluated a new technique for pain relief during TRUS biopsy. PATIENTS AND METHODS In Group 1 (n = 60), the biopsies were taken without any analgesia. In Group 2 (n = 60), 11 ml of Instillagel (2% lignocaine) was administered rectally prior to probe insertion and 5 ml of 1% lignocaine periprostatic injection was administered before taking the biopsy. The discomfort encountered during the procedure was graded by the patient on a scale ranging from no discomfort to mild, moderate and severe pain. RESULTS In Group 2, there was a marked reduction in the pain experienced during the procedure. The Chi-squared test for trend showed a significant association between the rectal administration of local anaesthetic gel and reduction in pain on probe insertion (P = 0.0001). There was also a significant association between the use of periprostatic lignocaine injection and reduction in pain on taking the biopsy (P < 0.0001). CONCLUSIONS The use of lignocaine gel prior to probe insertion and periprostatic infiltration of lignocaine before taking the needle biopsy significantly reduces the pain experienced by the patient during TRUS-guided prostate biopsy. PMID:16551424

  7. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches

    PubMed Central

    Song, Sang-Eun; Cho, Nathan B.; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2011-01-01

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. PMID:21399734

  8. BiopSee® - transperineal stereotactic navigated prostate biopsy.

    PubMed

    Zogal, Pawel; Sakas, Georgios; Rösch, Woerner; Baltas, Dimos

    2011-06-01

    In the recent years, prostate cancer was the most commonly diagnosed cancer in men. Currently secure diagnosis confirmation is done by a transrectal biopsy and following histopathological examination. Conventional transrectal biopsy success rates are rather low with ca. 30% detection upon the first and ca 20% after re-biopsy. The paper presents a novel system for stereotactic navigated prostate biopsy. The approach results into higher accuracy, reproducibility and unrestricted and effective access to all prostate regions. Custom designed ultrasound, new template design and integrated 2-axes stepper allows superior 2D and 3D prostate imaging quality and precise needle navigation. DICOM functionality and image fusion enable to import pre-operative datasets (e.g. multiparametric MRI, targets etc.) and overlay all available radiological information into the biopsy planning and guiding procedure. The biopsy needle insertion itself is performed under augmented reality ultrasound guidance. Each procedure step is automatically documented in order to provide quality assurance and permit data re-usage for the further treatment. First clinical results indicates success rates of ca. 70% by first biopsies by our approach.

  9. Prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy: A prospective multicenter study.

    PubMed

    Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon

    2018-03-01

    To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.

  10. Diclofenac Suppository as a Preemptive Analgesia in Ultrasound-guided Biopsy of Prostate: Randomized Controlled Trial.

    PubMed

    Haroon, Naveed; Ather, M Hammad; Khan, Salma; Kumar, Pirkash; Salam, Basit

    2015-10-01

    To compare preprocedure Diclofenac suppository and Xylocaine gel with Xylocaine gel only in patients undergoing transrectal ultrasound (TRUS)-guided biopsy of prostate for pain. It is a randomized controlled trial conducted on patients undergoing TRUS-guided biopsy for clinical or biochemical suspicion of prostate cancer following a written informed consent and Ethics Review Committee approval. Patients were randomized into 2 groups. Group A included those patients who received Diclofenac suppository 2 hours before in combination with 10 mL of 2% Xylocaine gel 5 minutes before biopsy. Group B received Xylocaine gel only. A visual analog scale was used to measure the pain scores at the time of TRUS probe insertion, just after taking biopsy cores and 2 hours after biopsy. A total of 100 patients were recruited in the study with 50 patients each in group A and B. Mean age of group A was 69.1 ± 10 years and 67.3 ± 8.1 years for group B. The mean pain score for group A and B at the time of probe insertion was 0.08 ± 0.27 and 0.34 ± 0.63 (P = .032), immediately after taking biopsy cores was 1.46 ± 1.15 and 4.68 ± 0.77 (P = .000), and 2 hours after biopsy was 0.14 ± 0.45 vs 2.40 ± 0.81 (P = .000), respectively. The mean pain score at the time of TRUS probe insertion, immediately after taking biopsy cores, and 2 hours after biopsy is statistically significantly higher in group B. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Optimization of prostate biopsy: the role of magnetic resonance imaging targeted biopsy in detection, localization and risk assessment.

    PubMed

    Bjurlin, Marc A; Meng, Xiaosong; Le Nobin, Julien; Wysock, James S; Lepor, Herbert; Rosenkrantz, Andrew B; Taneja, Samir S

    2014-09-01

    Optimization of prostate biopsy requires addressing the shortcomings of standard systematic transrectal ultrasound guided biopsy, including false-negative rates, incorrect risk stratification, detection of clinically insignificant disease and the need for repeat biopsy. Magnetic resonance imaging is an evolving noninvasive imaging modality that increases the accurate localization of prostate cancer at the time of biopsy, and thereby enhances clinical risk assessment and improves the ability to appropriately counsel patients regarding therapy. In this review we 1) summarize the various sequences that comprise a prostate multiparametric magnetic resonance imaging examination along with its performance characteristics in cancer detection, localization and reporting standards; 2) evaluate potential applications of magnetic resonance imaging targeting in prostate biopsy among men with no previous biopsy, a negative previous biopsy and those with low stage cancer; and 3) describe the techniques of magnetic resonance imaging targeted biopsy and comparative study outcomes. A bibliographic search covering the period up to October 2013 was conducted using MEDLINE®/PubMed®. Articles were reviewed and categorized based on which of the 3 objectives of this review was addressed. Data were extracted, analyzed and summarized. Multiparametric magnetic resonance imaging consists of anatomical T2-weighted imaging coupled with at least 2 functional imaging techniques. It has demonstrated improved prostate cancer detection sensitivity up to 80% in the peripheral zone and 81% in the transition zone. A prostate cancer magnetic resonance imaging suspicion score has been developed, and is depicted using the Likert or PI-RADS (Prostate Imaging Reporting and Data System) scale for better standardization of magnetic resonance imaging interpretation and reporting. Among men with no previous biopsy, magnetic resonance imaging increases the frequency of significant cancer detection to 50

  12. Penthrox inhaler analgesia in transrectal ultrasound-guided prostate biopsy.

    PubMed

    Lee, Chanyang; Woo, Henry H

    2015-06-01

    Periprostatic injection of local anaesthetic (PILA) has been shown to significantly reduce pain in patients undergoing transrectal ultrasound-guided prostate biopsy (TRUSPB). However, this method does not address pain that is associated with ultrasound probe insertion, and the injection of local anaesthetic itself causes pain. The aim of this study was to explore the efficacy of methoxyflurane delivered by a Penthrox inhaler as a novel method of pain relief during TRUSPB. From July 2012 to July 2013, 64 patients were scheduled at a single centre to undergo TRUSPB while receiving analgesia via Penthrox inhaler. Fifteen minutes after the biopsy procedure, these patients were asked to complete a pain score survey using a 10-cm visual analogue scale (VAS) to separately report the degree of pain experienced during digital rectal examination (DRE), ultrasound probe insertion and core biopsy. The median pain scores on a 10-cm VAS were 2.0, 2.4 and 3.0 during DRE, probe insertion and needle biopsy, respectively, while using the Penthrox inhaler. Of the 64 patients, 11 had undergone TRUSPB previously receiving PILA. In these patients, PILA was significantly better than the Penthrox inhaler for pain relief during needle biopsy (median pain score 2.0 versus 4.0; P = 0.012). The Penthrox inhaler appears to be a safe and effective method of analgesia for TRUSPB. Patients who had experienced both PILA and Penthrox reported pain scores that significantly favoured PILA over the Penthrox inhaler. © 2014 Royal Australasian College of Surgeons.

  13. Penthrox alone versus Penthrox plus periprostatic infiltration of local analgesia for analgesia in transrectal ultrasound-guided prostate biopsy.

    PubMed

    Huang, Sean; Pepdjonovic, Lana; Konstantatos, Alex; Frydenberg, Mark; Grummet, Jeremy

    2016-03-01

    The objective of this study was to compare pain intensity in patients undergoing transrectal ultrasound (TRUS)-guided biopsy of the prostate with Penthrox alone compared with Penthrox plus periprostatic infiltration of local analgesia (PILA). Seventy-two subjects participated in this study after receiving appropriate education. Forty-two patients self-administered inhaled Penthrox (3 mL methoxyflurane) alone for analgesia (Group A), followed by 30 patients who self-administered Penthrox and received PILA with 5 mL of 2% lignocaine. All subjects had TRUS biopsy performed. Immediately after the procedure, patients were asked to rate their pain intensity using a numerical verbal rating scale from 0 to 10. Baseline characteristics of the two groups were similar. Patients in Group B reported significantly lower post TRUS biopsy median pain intensity of 2 (1-3) compared with Group A subjects who reported a median post TRUS biopsy pain intensity of 3 (2-5) (P = 0.014). A total of 72 men underwent TRUS-guided biopsy. All patients indicated they would be happy to have another TRUS-guided prostate biopsy in the future. Our study shows that Penthrox plus PILA shows promise as an efficacious and easily tolerated analgesic technique for outpatient TRUS biopsy, keeping resource use to a minimum. Planning for a multi-centre, double-blind randomized control trial comparing Penthrox plus PILA with PILA alone is presently underway. © 2015 Royal Australasian College of Surgeons.

  14. Randomized comparison of power Doppler ultrasonography-guided core-needle biopsy with open surgical biopsy for the characterization of lymphadenopathies in patients with suspected lymphoma.

    PubMed

    Pugliese, Novella; Di Perna, M; Cozzolino, I; Ciancia, G; Pettinato, G; Zeppa, P; Varone, V; Masone, S; Cerchione, C; Della Pepa, R; Simeone, L; Giordano, C; Martinelli, V; Salvatore, C; Pane, F; Picardi, M

    2017-04-01

    The sensitivity of lymph node core-needle biopsy under imaging guidance requires validation. We employed power Doppler ultrasonography (PDUS) to select the lymph node most suspected of malignancy and to histologically characterize it through the use of large cutting needle. Institutional review board approval and informed consent were obtained for this randomized clinical trial. In a single center between 1 January 2009 and 31 December 2015, patients with lymph node enlargement suspected for lymphoma were randomly assigned (1:1) to biopsy with either standard surgery or PDUS-guided 16-gauge modified Menghini needle. The primary endpoint was the superiority of sensitivity for the diagnosis of malignancy for core-needle cutting biopsy (CNCB). Secondary endpoints were times to biopsy, complications, and costs. A total of 376 patients were randomized into the two arms and received allocated biopsy. However, four patients undergoing CNCB were excluded for inadequate samples; thus, 372 patients were analyzed. Sensitivity for the detection of malignancy was significantly better for PDUS-guided CNCB [98.8%; 95% confidence interval (CI), 95.9-99.9] than standard biopsy (88.7%; 95% CI, 82.9-93; P < 0.001). For all secondary endpoints, the comparison was significantly disadvantageous for conventional approach. In particular, estimated cost per biopsy performed with standard surgery was 24-fold higher compared with that performed with CNCB. The presence of satellite enlarged reactive and/or necrotic lymph nodes may impair the success of an open surgical biopsy (OSB). PDUS and CNCB with adequate gauge are diagnostic tools that enable effective, safe, fast, and low-cost routine biopsy for patients with suspected lymphoma, avoiding psychological and physical pain of an unnecessary surgical intervention.

  15. Detection rate of prostate cancer following biopsy among the northern Han Chinese population: a single-center retrospective study of 1022 cases.

    PubMed

    Jia, Yong; Zhu, Lei-Yi; Xian, Yu-Xin; Sun, Xiao-Qing; Gao, Jian-Gang; Zhang, Xin-Hong; Hou, Si-Chuan; Zhang, Chang-Cun; Liu, Zhao-Xu

    2017-08-29

    Prostate cancer is known to have ethnic and regional differences. The study aimed to clinically evaluate the detection rate of prostate cancer on transrectal ultrasonography (TRUS)-guided prostate biopsy and analyze its characteristics among the northern Han Chinese population at a single center. Between October 2009 and September 2016, a total of 1027 Chinese men, who had undergone TRUS-guided prostate biopsy at Qingdao Municipal Hospital, were retrospectively analyzed. Prostate biopsies were performed in the case of an abnormally elevated serum PSA level, and/or abnormal digital rectal examination (DRE) findings, and/or suspicious prostatic imaging findings. Of the 1022 men enrolled in the analysis, 438 patients (42.8%) were diagnosed with prostate adenocarcinoma histologically. When serum PSA levels were divided into five subgroups (less than 4.0, 4.0 to 10.0, 10.0 to 20.0, 20.0 to 100.0, and ≥ 100.0 ng/ml), the detection rates of prostate cancer were 12.4, 15.9, 34.1, 66.2, and 93.8%, respectively. With serum PSA levels of 4.0 to 10.0 ng/ml, the cancer detection rates for a normal DRE and a suspect DRE finding were 13.5 and 58.2%, respectively. Accordingly, the cancer detection rates for a normal imaging and a suspect imaging finding were 13.5 and 58.2%, respectively. Besides, a large proportion of the patients were in the clinically advanced stage. The present study data reported a relatively higher prostate cancer detection rate of 42.8% and that the majority of the patients presented with clinically advanced prostate cancers within a local clinical urologic practice. An early detection and screening program for prostate cancer is of great need to reduce the burden from this disease among the northern Han Chinese population.

  16. A Single Center Evaluation of the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging against Transperineal Prostate Mapping Biopsy: An Analysis of Men with Benign Histology and Insignificant Cancer following Transrectal Ultrasound Biopsy.

    PubMed

    Pal, Raj P; Ahmad, Ros; Trecartan, Shaun; Voss, James; Ahmed, Shaista; Bazo, Alvaro; Lloyd, Jon; Walton, Thomas J

    2018-03-01

    In this study we evaluated the diagnostic performance of transrectal ultrasound guided biopsy and multiparametric magnetic resonance imaging to detect prostate cancer against transperineal prostate mapping biopsy as the reference test. Transrectal ultrasound guided biopsy, multiparametric magnetic resonance imaging and transperineal prostate mapping biopsy were performed in 426 patients between April 2012 and January 2016. Patients initially underwent systematic 12 core transrectal ultrasound guided biopsy followed 3 months later by 1.5 Tesla, high resolution T2, diffusion-weighted, dynamic contrast enhanced multiparametric magnetic resonance imaging. Two specialist uroradiologists blinded to the results of transperineal prostate mapping biopsy allocated a PI-RADS™ (Prostate Imaging-Reporting and Data System) score to each multiparametric magnetic resonance imaging study. Transperineal prostate mapping biopsy with 5 mm interval sampling, which was performed within 6 months of multiparametric magnetic resonance imaging, served as the reference test. Transrectal ultrasound guided biopsy identified 247 of 426 patients with prostate cancer and 179 of 426 with benign histology. Transperineal prostate mapping biopsy detected prostate cancer in 321 of 426 patients. On transperineal prostate mapping biopsy 94 of 179 patients with benign transrectal ultrasound guided biopsy had prostate cancer and 95 of 247 with prostate cancer on transrectal ultrasound guided biopsy were identified with cancer of higher grade. Using a multiparametric magnetic resonance imaging PI-RADS score of 3 or greater to detect significant prostate cancer, defined as any core containing Gleason 4 + 3 or greater prostate cancer on transperineal prostate mapping biopsy, the ROC AUC was 0.754 (95% CI 0.677-0.819) with 87.0% sensitivity (95% CI 77.3-97.0), 55.3% specificity (95% CI 50.2-60.4) and 97.1% negative predictive value (95% CI 94.8-99.4). Multiparametric magnetic resonance imaging is a more

  17. 3T MR-guided in-bore transperineal prostate biopsy: A comparison of robotic and manual needle-guidance templates.

    PubMed

    Tilak, Gaurie; Tuncali, Kemal; Song, Sang-Eun; Tokuda, Junichi; Olubiyi, Olutayo; Fennessy, Fiona; Fedorov, Andriy; Penzkofer, Tobias; Tempany, Clare; Hata, Nobuhiko

    2015-07-01

    To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer. © 2014 Wiley Periodicals, Inc.

  18. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    PubMed

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason < 7 group and Gleason > 7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  19. Role of information in preparing men for transrectal ultrasound guided prostate biopsy: a qualitative study embedded in the ProtecT trial.

    PubMed

    Wade, Julia; Rosario, Derek J; Howson, Joanne; Avery, Kerry N L; Salter, C Elizabeth; Goodwin, M Louise; Blazeby, Jane M; Lane, J Athene; Metcalfe, Chris; Neal, David E; Hamdy, Freddie C; Donovan, Jenny L

    2015-02-28

    The histological diagnosis of prostate cancer requires a prostate needle biopsy. Little is known about the relationship between information provided to prepare men for transrectal ultrasound guided biopsy (TRUS-Bx) and how men experience biopsy. The objectives were a) to understand men's experiences of biopsy as compared to their expectations; and b) to propose current evidence-based information for men undergoing TRUS-Bx. Between February 2006 and May 2008, 1,147 men undergoing a standardised 10-core transrectal ultrasound guided biopsy protocol under antibiotic cover following a PSA 3.0-19.9 ng/ml in the Prostate Testing for Cancer and Treatment (ProtecT) trial, completed questionnaires about biopsy symptoms. In this embedded qualitative study, in-depth interviews were undertaken with 85 men (mean age 63.6 yrs, mean PSA 4.5 ng/ml) to explore men's experiences of prostate biopsy and how the experience might be improved. Interview data were analysed thematically using qualitative research methods. Findings from the qualitative study were used to guide selection of key findings from the questionnaire study in developing a patient information leaflet preparing men for biopsy. Although most men tolerated TRUS-Bx, a quarter reported problematic side-effects and anxiety. Side effects were perceived as problematic and anxiety arose most commonly when experiences deviated from information provided. Men who were unprepared for elements of TRUS-Bx procedure or its sequelae responded by contacting health professionals for reassurance and voiced frustration that pre-biopsy information had understated the possible severity or duration of pain/discomfort and bleeding. Findings from questionnaire and interview data were combined to propose a comprehensive, evidence-based patient information leaflet for TRUS-Bx. Men reported anxiety associated with TRUS-Bx or its side-effects most commonly if they felt inadequately prepared for the procedure. Data from this qualitative study and

  20. 2D-3D rigid registration to compensate for prostate motion during 3D TRUS-guided biopsy.

    PubMed

    De Silva, Tharindu; Fenster, Aaron; Cool, Derek W; Gardi, Lori; Romagnoli, Cesare; Samarabandu, Jagath; Ward, Aaron D

    2013-02-01

    Three-dimensional (3D) transrectal ultrasound (TRUS)-guided systems have been developed to improve targeting accuracy during prostate biopsy. However, prostate motion during the procedure is a potential source of error that can cause target misalignments. The authors present an image-based registration technique to compensate for prostate motion by registering the live two-dimensional (2D) TRUS images acquired during the biopsy procedure to a preacquired 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. The authors implemented an intensity-based 2D-3D rigid registration algorithm optimizing the normalized cross-correlation (NCC) metric using Powell's method. The 2D TRUS images acquired during the procedure prior to biopsy gun firing were registered to the baseline 3D TRUS image acquired at the beginning of the procedure. The accuracy was measured by calculating the target registration error (TRE) using manually identified fiducials within the prostate; these fiducials were used for validation only and were not provided as inputs to the registration algorithm. They also evaluated the accuracy when the registrations were performed continuously throughout the biopsy by acquiring and registering live 2D TRUS images every second. This measured the improvement in accuracy resulting from performing the registration, continuously compensating for motion during the procedure. To further validate the method using a more challenging data set, registrations were performed using 3D TRUS images acquired by intentionally exerting different levels of ultrasound probe pressures in order to measure the performance of our algorithm when the prostate tissue was intentionally deformed. In this data set, biopsy scenarios were simulated by extracting 2D frames from the 3D TRUS images and registering them to the baseline 3D image. A graphics processing unit (GPU)-based implementation was used to improve the

  1. Evolution of prostate biopsy techniques. Looking back on a meaningful journey.

    PubMed

    Sivaraman, A; Sanchez-Salas, R; Castro-Marin, M; Barret, E; Guillot-Tantay, C; Prapotnich, D; Cathelineau, X

    2016-10-01

    The technique of prostate biopsy has evolved a long way since its inception to being a safe diagnostic procedure. The principles of the biopsy technique continue to improvise with the knowledge about prostate cancer and availability of newer treatment options like active surveillance and focal therapy. Currently, we depend on accurate cancer information from the biopsy more than ever for deciding the ideal treatment option. The aim of this review is to present the major milestones in prostate biopsy technique evolutions and its impact on the prostate cancer management. We performed a detailed non-systematic literature review to present the historical facts on the transformations in prostate biopsy techniques and also the direction of present research to improve accurate cancer detection. There is a clear change in trend in biopsy technique before and after the introduction of transrectal ultrasound and prostate specific antigen. In the earlier era, the biopsies were aimed at palpable nodules and obtaining adequate prostatic tissue for diagnosis while the later era has moved towards detection of non-palpable and early prostate cancer. Recently, there is an increasing trend towards image guided targeted biopsies to extract maximum cancer information from minimum biopsy cores. Prostate biopsy techniques have seen major changes since its inception and have a major impact on prostate cancer management. There is a great potential for research which can further support the newer treatment options like focal therapy. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Is there a role for anterior zone sampling as part of saturation trans-rectal ultrasound guided prostate biopsy?

    PubMed

    Cole, Eric; Margel, David; Greenspan, Michael; Shayegan, Bobby; Matsumoto, Edward; Fischer, Marc A; Patlas, Michael; Daya, Dean; Pinthus, Jehonathan H

    2014-05-03

    The prostatic anterior zone (AZ) is not targeted routinely by TRUS guided prostate biopsy (TRUS-Pbx). MRI is an accurate diagnostic tool for AZ tumors, but is often unavailable due to cost or system restrictions. We examined the diagnostic yield of office based AZ TRUS-Pbx. 127 men at risk for AZ tumors were studied: Patients with elevated PSA and previous extended negative TRUS-Pbx (group 1, n = 78) and actively surveyed low risk prostate cancer patients (group 2, n = 49). None of the participants had a previous AZ biopsy. Biopsy template included suspicious ultrasonic areas, 16 peripheral zone (PZ), 4 transitional zone (TZ) and 6 AZ cores. All biopsies were performed by a single urologist under local peri-prostatic anaesthetic, using the B-K Medical US System, an end-firing probe 4-12 MHZ and 18 ga/25 cm needle. All samples were reviewed by a single specialized uro-pathologist. Multivariate analysis was used to detect predictors for AZ tumors accounting for age, PSA, PSA density, prostate volume, BMI, and number of previous biopsies. Median PSA was 10.4 (group 1) and 7.3 (group 2). Age (63.9, 64.5), number of previous biopsies (1.5) and cores (17.8, 21.3) and prostate volume (56.4 cc, 51 cc) were similar for both groups. The overall diagnostic yield was 34.6% (group 1) and 85.7% (group 2). AZ cancers were detected in 21.8% (group 1) and 34.7% (group 2) but were rarely the only zone involved (1.3% and 4.1% respectively). Gleason ≥ 7 AZ cancers were often accompanied by equal grade PZ tumors. In multivariate analysis only prostate volume predicted for AZ tumors. Patients detected with AZ tumors had significantly smaller prostates (36.9 cc vs. 61.1 cc p < 0.001). Suspicious AZ ultrasonic findings were uncommon (6.3%). TRUS-Pbx AZ sampling rarely improves the diagnostic yield of extended PZ sampling in patients with elevated PSA and previous negative biopsies. In low risk prostate cancer patients who are followed by active surveillance, AZ sampling changes risk

  3. Can one blood draw replace transrectal ultrasonography-estimated prostate volume to predict prostate cancer risk?

    PubMed

    Carlsson, Sigrid V; Peltola, Mari T; Sjoberg, Daniel; Schröder, Fritz H; Hugosson, Jonas; Pettersson, Kim; Scardino, Peter T; Vickers, Andrew J; Lilja, Hans; Roobol, Monique J

    2013-09-01

    To explore whether a panel of kallikrein markers in blood: total, free and intact prostate-specific antigen (PSA) and kallikrein-related peptidase 2, could be used as a non-invasive alternative for predicting prostate cancer on biopsy in a screening setting. The study cohort comprised previously unscreened men who underwent sextant biopsy owing to elevated PSA (≥3 ng/mL) in two different centres of the European Randomized Study of Screening for Prostate Cancer, Rotterdam (n = 2914) and Göteborg (n = 740). A statistical model, based on kallikrein markers, was compared with one based on established clinical factors for the prediction of biopsy outcome. The clinical tests were found to be no better than blood markers, with an area under the curve in favour of the blood measurements of 0.766 vs. 0.763 in Rotterdam and 0.809 vs. 0.774 in Göteborg. Adding digital rectal examination (DRE) or DRE plus transrectal ultrasonography (TRUS) volume to the markers improved discrimination, although the increases were small. Results were similar for predicting high-grade cancer. There was a strong correlation between the blood measurements and TRUS-estimated prostate volume (Spearman's correlation 0.60 in Rotterdam and 0.57 in Göteborg). In previously unscreened men, each with indication for biopsy, a statistical model based on kallikrein levels was similar to a clinical model in predicting prostate cancer in a screening setting, outside the day-to-day clinical practice. Whether a clinical approach can be replaced by laboratory analyses or used in combination with decision models (nomograms) is a clinical judgment that may vary from clinician to clinician depending on how they weigh the different advantages and disadvantages (harms, costs, time, invasiveness) of both approaches. © 2013 BJU International.

  4. Does a previous prostate biopsy-related acute bacterial prostatitis affect the results of radical prostatectomy?

    PubMed

    Türk, Hakan; Ün, Sitki; Arslan, Erkan; Zorlu, Ferruh

    2018-01-01

    To The standard technique for obtaining a histologic diagnosis of prostatic carcinomas is transrectal ultrasound guided prostate biopsy. Acute prostatitis which might develop after prostate biopsy can cause periprostatic inflammation and fibrosis. In this study, we performed a retrospective review of our database to determine whether ABP history might affect the outcome of RP. 441 RP patients who were operated in our clinic from 2002 to 2014 were included in our study group. All patients' demographic values, PSA levels, biopsy and radical prostatectomy specimen pathology results and their perioperative/postoperative complications were evaluated. There were 41 patients in patients with acute prostatitis following biopsy and 397 patients that did not develop acute prostatitis. Mean blood loss, transfusion rate and operation period were found to be significantly higher in ABP patients. Hospitalization period and reoperation rates were similar in both groups. However, post-op complications were significantly higher in ABP group. Even though it does not affect oncological outcomes, we would like to warn the surgeons for potential complaints during surgery in ABP patients. Copyright® by the International Brazilian Journal of Urology.

  5. Repeat prostate-specific antigen (PSA) test before prostate biopsy: a 20% decrease in PSA values is associated with a reduced risk of cancer and particularly of high-grade cancer.

    PubMed

    De Nunzio, Cosimo; Lombardo, Riccardo; Nacchia, Antonio; Tema, Giorgia; Tubaro, Andrea

    2018-07-01

    To analyse the impact of repeating a prostate-specific antigen (PSA) level assessment on prostate biopsy decision in a cohort of men undergoing prostate biopsy. From 2015 onwards, we consecutively enrolled, at a single institution in Italy, men undergoing 12-core transrectal ultrasonography-guided prostate needle biopsy. Indication for prostate biopsy was a PSA level of ≥4 ng/mL. Demographic, clinical, and histopathological data were collected. The PSA level was tested at enrolment (PSA 1 ) and 4 weeks later on the day before biopsy (PSA 2 ). Variations in PSA level were defined as: stable PSA 2 within a 10% variation, stable PSA 2 within a 20% variation, PSA 2 decreased by ≥10%, PSA 2 decreased by ≥20%, PSA 2 increased by ≥10%, PSA 2 increased by ≥20%, and PSA 2 <4 ng/mL. Percentages and multinomial logistic regression were used to analyse biopsy outcomes. High-grade cancer was defined as Grade group ≥3. Overall, 331 patients were enrolled. Prostate cancer was diagnosed in 153/331 (46%) patients and of them 80/153 (52%) had high-grade disease. When compared to the rest of the population, patients with a stable PSA within 20% variation had a higher risk of prostate cancer (odds ratio [OR] 1.80, P < 0.05) and high grade disease (OR 2.56, P < 0.05), patients with a PSA2 decreased by ≥20% had a lower risk of prostate cancer (OR 0.37, P < 0.05) and high grade disease (OR 0.13, P < 0.05), whilst patients with a PSA2 increased by ≥10% had an increased risk of high-grade prostate cancer (OR 1.93, P < 0.05). When PSA returned to normal values (<4 ng/mL) both risks of prostate cancer and high-grade disease were reduced (OR 0.33 and 0.01, respectively, P = 0.001). In a cohort of Italian men undergoing prostate biopsy, a reduction of ≥20% in PSA levels significantly reduced the risk of high-grade prostate cancer. Further multicentre studies should validate our present results. © 2018 The Authors BJU International © 2018 BJU International Published by John

  6. Magnetic resonance imaging-directed transperineal limited-mapping prostatic biopsies to diagnose prostate cancer: a Scottish experience.

    PubMed

    Mukherjee, Ankur; Morton, Simon; Fraser, Sioban; Salmond, Jonathan; Baxter, Grant; Leung, Hing Y

    2014-11-01

    Transperineal prostatic biopsy is firmly established as an important tool in the diagnosis of prostate cancer. The benefit of additional imaging (magnetic resonance imaging) to target biopsy remains to be fully addressed. Using a cohort of consecutive patients undergoing transperineal template mapping biopsies, we studied positive biopsies in the context of magnetic resonance imaging findings and examined the accuracy of magnetic resonance imaging in predicting the location of transperineal template mapping biopsies-detected prostate cancer. Forty-four patients (mean age: 65 years, range 53-78) underwent transperineal template mapping biopsies. Thirty-four patients had 1-2 and 10 patients had ≥3 previous transrectal ultrasound scan-guided biopsies. The mean prostate-specific antigen was 15 ng/mL (range 2.5-79 ng/mL). High-grade prostatic intraepithelial neoplasia was found in 12 (27%) patients and prostate cancer with Gleason <7, 7 and >7 in 13, 10 and 8 patients, respectively. Suspicious lesions on magnetic resonance imaging scans were scored from 1 to 5. In 28 patients, magnetic resonance imaging detected lesions with score ≥3. Magnetic resonance imaging correctly localised transperineal template mapping biopsies-detected prostate cancer in a hemi-gland approach, particularly in a right to left manner (79% positive prediction rate), but not in a quadrant approach (33% positive prediction rate). Our findings support the notion of magnetic resonance imaging-based selection of patients for transperineal template mapping biopsies and that lesions revealed by magnetic resonance imaging are likely useful for targeted biopsies. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Optical biopsy of the prostate: can we TRUST (trans-rectal ultrasound-coupled spectral tomography)?

    NASA Astrophysics Data System (ADS)

    Piao, Daqing; Jiang, Zhen; Bartels, Kenneth E.; Holyoak, G. Reed; Ritchey, Jerry W.; Rock, Kendra; Ownby, Charlotte L.; Bunting, Charles F.; Slobodov, Gennady

    2011-03-01

    Needle-based core-biopsy to locate prostate cancer relies heavily upon trans-rectal ultrasound (TRUS) imaging guidance. Ultrasonographic findings of classic hypoechoic peripheral zone lesions have a low specificity of ~28%, a low positive predictive value of ~29%, and an overall accuracy of ~43%, in prostate cancer diagnosis. The prevalence of isoechoic or nearly invisible prostate cancers on ultrasonography ranges from 25 to 42%. As a result, TRUS is useful and convenient to direct the needle trajectory following a systematic biopsy sampling template rather than to target only the potentially malignant lesion for focal-biopsy. To address this deficiency in the first-line of prostate cancer imaging, a trans-rectal ultrasound-coupled spectral tomography (TRUST) approach is being developed to non-invasively resolve the likely optical signatures of prostate malignancy. The approach has evolved from using one NIR wavelength to two NIR bands, and recently to three bands of NIR spectrum information. The concept has been evaluated on one normal canine prostate and three dogs with implanted prostate tumor developed as a model. The initial results implementing TRUST on the canine prostate tumor model includes: (1) quantifying substantially increased total hemoglobin concentration over the time-course of imaging in a rapidly growing prostate tumor; (2) confirming hypoxia in a prostatic cystic lesion; and (3) imaging hypoxic changes of a necrotic prostate tumor. Despite these interesting results, intensive technologic development is necessary for translating the approach to benefiting clinical practice, wherein the ultimate utility is not possibly to eliminate needle-biopsy but to perform focal-biopsy that is only necessary to confirm the cancer, as well as to monitor and predict treatment responses.

  8. Microbiological Characteristics of Acute Prostatitis After Transrectal Prostate Biopsy

    PubMed Central

    Bang, Jun-Ho; Choe, Hyun-Sop; Lee, Dong-Sup; Lee, Seung-Ju

    2013-01-01

    Purpose We aimed to identify microbiological characteristics in patients with acute prostatitis after transrectal prostate biopsy to provide guidance in the review of prevention and treatment protocols. Materials and Methods A retrospective analysis of medical records was performed in 1,814 cases who underwent prostate biopsy at Seoul St. Mary's Hospital and St. Vincent's Hospital over a 5 year period from 2006 to 2011. Cases in which acute prostatitis occurred within 7 days after the biopsy were investigated. Before starting treatment with antibiotics, sample collections were done for culture of urine and blood. Culture and drug susceptibility was identified by use of a method established by the Clinical and Laboratory Standards Institute. Results A total of 1,814 biopsy procedures were performed in 1,541 patients. For 1,246 patients, the procedure was the first biopsy, whereas for 295 patients it was a repeat biopsy. Twenty-one patients (1.36%) were identified as having acute bacterial prostatitis after the biopsy. Fifteen patients (1.2%) had acute prostatitis after the first biopsy, and 6 patients (2.03%) experienced acute prostatitis after a repeat biopsy. Even though the incidence of acute bacterial prostatitis was higher after repeat biopsy than that after the first biopsy, there was no statistically significant intergroup difference in terms of incidence (χ2=1.223, p=0.269). When the collected urine and blood samples were cultured, Escherichia coli was found in samples from 15 patients (71.4%), Klebsiella pneumoniae in 3 patients (14.3%), Enterobacter intermedius in 1 patient (4.8%), E. aerogenes in 1 patient (4.8%), and Pseudomonas aeruginosa in 1 patient (4.8%). A fluoroquinolone-resistant strain was confirmed in 5 cases (23.8%) in total. Three cases of E. coli and 1 case of Klebsiella had extended-spectrum β-lactamase activity. Conclusions Empirical treatment of acute prostatitis should be done with consideration of geographical prevalence and drug

  9. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    PubMed

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. [Image fusion: use in the control of the distribution of prostatic biopsies].

    PubMed

    Mozer, Pierre; Baumann, Michaël; Chevreau, Grégoire; Troccaz, Jocelyne

    2008-02-01

    Prostate biopsies are performed under 2D TransRectal UltraSound (US) guidance by sampling the prostate according to a predefined pattern. Modern image processing tools allow better control of biopsy distribution. We evaluated the accuracy of a single operator performing a pattern of 12 ultrasound-guided biopsies by registering 3D ultrasound control images acquired after each biopsy. For each patient, prostate image alignment was performed automatically with a voxel-based registration algorithm allowing visualization of each biopsy trajectory in a single ultrasound reference volume. On average, the operator reached the target in 60% of all cases. This study shows that it is difficult to accurately reach targets in the prostate using 2D ultrasound. In the near future, real-time fusion of MRI and US images will allow selection of a target in previously acquired MR images and biopsy of this target by US guidance.

  11. [MRI/TRUS fusion-guided prostate biopsy : Value in the context of focal therapy].

    PubMed

    Franz, T; von Hardenberg, J; Blana, A; Cash, H; Baumunk, D; Salomon, G; Hadaschik, B; Henkel, T; Herrmann, J; Kahmann, F; Köhrmann, K-U; Köllermann, J; Kruck, S; Liehr, U-B; Machtens, S; Peters, I; Radtke, J P; Roosen, A; Schlemmer, H-P; Sentker, L; Wendler, J J; Witzsch, U; Stolzenburg, J-U; Schostak, M; Ganzer, R

    2017-02-01

    Several systems for MRI/TRUS fusion-guided biopsy of the prostate are commercially available. Many studies have shown superiority of fusion systems for tumor detection and diagnostic quality compared to random biopsy. The benefit of fusion systems in focal therapy of prostate cancer (PC) is less clear. Critical considerations of fusion systems for planning and monitoring of focal therapy of PC were investigated. A systematic literature review of available fusion systems for the period 2013-5/2016 was performed. A checklist of technical details, suitability for special anatomic situations and suitability for focal therapy was established by the German working group for focal therapy (Arbeitskreis fokale und Mikrotherapie). Eight fusion systems were considered (Artemis™, BioJet, BiopSee®, iSR´obot™ Mona Lisa, Hitachi HI-RVS, UroNav and Urostation®). Differences were found for biopsy mode (transrectal, perineal, both), fusion mode (elastic or rigid), navigation (image-based, electromagnetic sensor-based or mechanical sensor-based) and space requirements. Several consensus groups recommend fusion systems for focal therapy. Useful features are "needle tracking" and compatibility between fusion system and treatment device (available for Artemis™, BiopSee® and Urostation® with Focal One®; BiopSee®, Hitachi HI-RVS with NanoKnife®; BioJet, BiopSee® with cryoablation, brachytherapy). There are a few studies for treatment planning. However, studies on treatment monitoring after focal therapy are missing.

  12. Recutting prostate needle core biopsies with high grade prostatic intraepithelial neoplasia increases detection of adenocarcinoma.

    PubMed

    Rapp, David E; Msezane, Lambda P; Reynolds, W Stuart; Lotan, Tamara L; Obara, Piotr; O'Connor, R Corey; Taxy, Jerome B; Gerber, Glenn S; Zagaja, Gregory P

    2009-02-01

    We sought to evaluate the ability of biopsy core recutting to increase cancer detection in patients with high grade prostatic intraepithelial neoplasia (HGPIN). This prospective study encompasses all patients undergoing 12 core TRUS guided prostate biopsy between February 2004 and January 2007. In patients with HGPIN on initial biopsy, the paraffin blocks were resampled for cancer by additional deeper levels per core. Additional analysis was performed in the patients with HGPIN in order to detect whether significant differences in prebiopsy variables were associated with patients subsequently found to have benign versus carcinoma on recutting. Last, the costs associated with this procedure were studied. Forty of 584 (6.8%) patients undergoing prostate biopsy were found to have HGPIN in the absence of prostatic adenocarcinoma on initial histopathology. Following recutting, 12.5% (5/40) of these patients were found to have prostatic adenocarcinoma not previously detected. Of the remaining 35 patients, 18 underwent repeat biopsy. Of these, five patients were found to have adenocarcinoma and three were found to have persistent HGPIN. The PSA, PSA density (PSAD), and PSA velocity (PSAV) prior to initial biopsy were not statistically different when comparing patients found to have benign tissue versus carcinoma on recutting. In patients with HGPIN, at our institution, recutting the biopsy would yield a cost savings of $436/patient as opposed to universal rebiopsy. Our data suggest that prostate biopsy recutting may increase cancer detection in patients initially found to have HGPIN. Additionally, a significant cost savings is associated with the recutting protocol.

  13. Skin and soft tissue infections: experience over a five-year period and clinical usefulness of ultrasonography-guided gun biopsy-based culture.

    PubMed

    Noh, Ji Yun; Cheong, Hee Jin; Song, Joon Young; Hong, Suk-Joo; Myung, Jae Sung; Choi, Won Suk; Jo, Yu Mi; Heo, Jung Yeon; Kim, Woo Joo

    2011-12-01

    Skin and soft tissue infections (SSTIs) are common clinical diseases, but only a few reports of microbiological data on SSTIs in Korea have been published. In practice, specimens are rarely obtained from infected lesions unless there is visible pus or an abscess pocket. However, identification of the causative pathogen is important, because of emerging drug resistance and the increase in immunocompromised hosts. The medical records of 760 adult cases of community-acquired SSTIs (CA-SSTIs) from September 2003 to August 2008 were reviewed retrospectively. We analyzed epidemio-clinical features and microbiological distributions of CA-SSTIs and evaluated the positive culture rate of several diagnostic methods, including swab, tissue biopsy, blind needle aspiration, ultrasonography (US)-guided needle aspiration, and US-guided gun biopsy. Most CA-SSTIs (76.1%) occurred in previously healthy persons without underlying diseases. Re-infections were identified in 76 (10%) patients and cirrhosis was an independent risk factor for re-infection (odds ratio 3.64, 95% confidence interval 1.36-9.76). The most commonly identified pathogen was methicillin-susceptible Staphylococcus aureus, and 3(rd)-generation cephalosporins were the most commonly used empirical antibiotics (47.9%). US-guided needle aspiration had a high positive culture rate of 73.9% and the positive culture rate of US-guided gun biopsy was 17.5%. Considering the microbiological distribution of CA-SSTIs in Korea, penicillinase-stable penicillin or a 1(st)-generation cephalosporin should be adequate for initial antibiotic treatment. US-guided needle aspiration was a good technique for the identification of causative pathogens, and additive productivity is expected with US-guided gun biopsy culture from lesions without fluid collection.

  14. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye

    2008-01-15

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs ofmore » a 10-cm{sup 2}-diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37{sup o}C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis.« less

  15. New Bacterial Infection in the Prostate after Transrectal Prostate Biopsy.

    PubMed

    Seo, Yumi; Lee, Gilho

    2018-04-23

    The prostate is prone to infections. Hypothetically, bacteria can be inoculated into the prostate during a transrectal prostate biopsy (TRPB) and progress into chronic bacterial prostatitis. Therefore, we examined new bacterial infections in biopsied prostates after TRPB and whether they affect clinical characteristics in the biopsied patients. Of men whose prostate cultures have been taken prior to TRPB, 105 men with bacteria-free benign prostate pathology underwent an additional repeated prostate culture within a year after TRPB. Twenty out of 105 men (19.05%) acquired new bacteria in their naïve prostates after TRPB. Except for one single case of Escherichia coli infection, 19 men had acquired gram-positive bacteria species. Between the culture-positive and negative groups, there were no significant differences in age, serum prostate-specific antigen (PSA) level, white blood cell (WBC) counts in expressed prostatic secretion (EPS), prostate volume, symptom severities in Korean version of the National Institutes of Health-Chronic Prostatitis Symptom Index (NIH-CPSI) questionnaire, and patient-specific risk factors for biopsy associated infectious complications. Additionally, the TRPB procedure increased the WBC counts in post-biopsy EPS ( P = 0.031, McNemar test), but did not increase the serum PSA level and symptoms of NIH-CPSI in 20 men who acquired new bacteria after TRPB. The TRPB procedure was significantly associated with acquiring new bacterial infections in the biopsied prostate, but these localized bacteria did not affect patients' serum PSA level and symptoms after biopsy.

  16. TU-CD-BRB-12: Radiogenomics of MRI-Guided Prostate Cancer Biopsy Habitats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoyanova, R; Lynne, C; Abraham, S

    2015-06-15

    Purpose: Diagnostic prostate biopsies are subject to sampling bias. We hypothesize that quantitative imaging with multiparametric (MP)-MRI can more accurately direct targeted biopsies to index lesions associated with highest risk clinical and genomic features. Methods: Regionally distinct prostate habitats were delineated on MP-MRI (T2-weighted, perfusion and diffusion imaging). Directed biopsies were performed on 17 habitats from 6 patients using MRI-ultrasound fusion. Biopsy location was characterized with 52 radiographic features. Transcriptome-wide analysis of 1.4 million RNA probes was performed on RNA from each habitat. Genomics features with insignificant expression values (<0.25) and interquartile range <0.5 were filtered, leaving total of 212more » genes. Correlation between imaging features, genes and a 22 feature genomic classifier (GC), developed as a prognostic assay for metastasis after radical prostatectomy was investigated. Results: High quality genomic data was derived from 17 (100%) biopsies. Using the 212 ‘unbiased’ genes, the samples clustered by patient origin in unsupervised analysis. When only prostate cancer related genomic features were used, hierarchical clustering revealed samples clustered by needle-biopsy Gleason score (GS). Similarly, principal component analysis of the imaging features, found the primary source of variance segregated the samples into high (≥7) and low (6) GS. Pearson’s correlation analysis of genes with significant expression showed two main patterns of gene expression clustering prostate peripheral and transitional zone MRI features. Two-way hierarchical clustering of GC with radiomics features resulted in the expected groupings of high and low expressed genes in this metastasis signature. Conclusions: MP-MRI-targeted diagnostic biopsies can potentially improve risk stratification by directing pathological and genomic analysis to clinically significant index lesions. As determinant lesions are more reliably

  17. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    PubMed

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  18. The eternal enigma in prostatic biopsy access route.

    PubMed

    Fabiani, Andrea; Principi, Emanuele; Filosa, Alessandra; Servi, Lucilla

    2017-10-03

    Dear Editors,We read with interest the article by Di Franco and co-workers (1). The introduction of prostatic magnetic resonance and the relative fusion-biopsy have not yet allowed the expected improvements in prostate biopsy. To our knowledge, there are no works that demonstrate the superiority of fusion techniques on the remaining ultrasound guided prostate biopsies that are still the widely used in the diagnosis of prostate cancer. Furthemore, these technologies are expensive exams and they are not yet available in all centers, especially in those minors. We work at a "minor" center and we always keep in mind that the goal of  prostatic biopsy is the diagnosis and the staging of prostatic neoplasms.. However, it remains uncertain which of the two techniques, transperineal (TP) or transrectal (TR), is superior in terms of detection rate during first biopsy setting. Several studies have compared the prostate cancer detection rate but TR and TP access route in prostatic gland sampling seems to be equivalent in terms of efficiency and complications, as reported by Shen PF et al. (2), despite several methodological limitations recognized in their work. The results reported by Di Franco CA et al. represent the real life experience of most urologists that perform the PB based on their own training experience and available technical devices. From an historical viewpoint, the TP route has been the first one to be used to reach the prostate, both for diagnostic and therapeutic purposes. To date, because it seems to be more invasive and difficult, the TP route is less used worldwide than the TR one (2). Theoretically, the TP approach should detect more prostate cancer than the TR way  because the cores of the TP approach are directed longitudinally to the peripheral zone and the anterior part of the prostate (4). The results reported by Di Franco et al. seems to confirm these considerations. However, our real life experience differ from the conclusions reached in their

  19. Cost-effectiveness of culture-guided antimicrobial prophylaxis for the prevention of infections after prostate biopsy.

    PubMed

    Li, Chi-Kong; Tong, Brian C Y; You, Joyce H S

    2016-02-01

    Clinical findings suggest that the use of rectal culture-guided antibiotic prophylaxis reduces the infection rate following transrectal ultrasound-guided prostate biopsy (TRUSBx). A decision-analytic model was designed to compare the outcomes of TRUSBx performed with (rectal culture-guided group) and without (standard ciprofloxacin prophylaxis) rectal swab culture-guided antimicrobial prophylaxis in Hong Kong. The post-biopsy infection rate, infection-related costs, quality-adjusted life years (QALYs) lost for infection, and incremental cost per QALY saved (ICER) were assessed. Model inputs were retrieved from local epidemiology data and the medical literature. A sensitivity analysis was performed to test the robustness of the model results. Base-case analysis showed that the infection rate in the culture-guided group was reduced from 2.42% to 0.23% and saved 0.0002 QALYs, with a lower cost (USD 31.4 versus USD 55.6) (USD 1=HKD 7.8). The number needed to screen to prevent an infection episode was 45.7. The hospital days avoided per 100 patients using culture-guided prophylaxis was 7.08 days. The relative effectiveness of culture-guided antimicrobial prophylaxis versus standard prophylaxis in carriers and non-carriers of FQ-resistant rectal flora were identified as potential influencing factors. In 10000 Monte Carlo simulations, ICERs of the culture-guided group were below the willingness-to-pay threshold 99.12% of the time. Using rectal culture-guided antimicrobial prophylaxis for men undergoing TRUSBx appears to be a cost-saving strategy to avert post-biopsy infection and QALY loss in Hong Kong. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Association of serum prostate-specific antigen levels with the results of the prostate needle biopsy.

    PubMed

    Janbaziroudsari, Hamid; Mirzaei, Arezoo; Maleki, Nasrollah

    2016-09-01

    To investigate the relationship of serum prostate-specific antigen (PSA) levels with outcomes of prostate needle biopsy in men 50 or more years old. We measured serum PSA levels in 1472 healthy men 50 or more years old. Men who had serum PSA values 4.0ng/mL or higher underwent digital rectal examination. If there were either an elevated PSA level (≥4ng/mL) or abnormal digital rectal examination, a transrectal ultrasound-guided prostate biopsy was performed. The mean serum total PSA level was 13.73±11.44ng/mL, and the mean serum free PSA level was 4.99±0.97ng/mL. Of the 260 men who had serum total PSA levels of≥4ng/mL, 139 underwent biopsy. Of these 139 men, 45 (32.4%) had prostate cancer. Benign prostatic hyperplasia with or without prostatitis was diagnosed in 94 patients (67.6%). There was no significant correlation between age and histologic results of prostate needle biopsy (P-value=0.469). The serum free PSA showed no significant correlation with histologic results of prostate needle biopsy, whereas the serum total PSA level had a significant correlation in patients with adenocarcinoma compared with other diagnosis. The overall frequency of detection of prostate adenocarcinoma was 32.4%. This study revealed that no level of PSA was associated with a 100% positive predictive value and negative biopsy can occur virtually at any PSA level. There is a need to create awareness among the general population and health professionals for an early diagnosis of this common form of cancer. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  1. Systematic ultrasound-guided saturation and template biopsy of the prostate: indications and advantages of extended sampling.

    PubMed

    Isbarn, Hendrik; Briganti, Alberto; De Visschere, Pieter J L; Fütterer, Jurgen J; Ghadjar, Pirus; Giannarini, Gianluca; Ost, Piet; Ploussard, Guillaume; Sooriakumaran, Prasanna; Surcel, Christian I; van Oort, Inge M; Yossepowitch, Ofer; van den Bergh, Roderick C N

    2015-04-01

    Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. A non-systematic review of the literature was performed from 2000 through 2013. Studies of highest evidence (randomized controlled trials, prospective non-randomized studies, and retrospective reports of high quality) comparing standard vs saturation schemes on initial and repeat PB were evaluated. Outcome measures were overall PCa detection rate, detection rate of insignificant PCa, and procedure-associated morbidity. On initial PB, there is growing evidence that a saturation scheme is associated with a higher PCa detection rate compared to a standard one in men with lower PSA levels (<10 ng/ml), larger prostates (>40 cc), or lower PSA density values (<0.25 ng/ml/cc). However, these cut-offs are not uniform and differ among studies. Detection rates of insignificant PCa do not differ in a significant fashion between standard and saturation biopsies. On repeat PB, PCa detection rate is likewise higher with saturation protocols. Estimates of insignificant PCa vary widely due to differing definitions of insignificant disease. However, the rates of insignificant PCa appear to be comparable for the schemes in patients with only one prior negative biopsy, while saturation biopsy seems to detect more cases of insignificant PCa compared to standard biopsy in men with two or more prior negative biopsies. Very extensive sampling is associated with a high rate of acute urinary retention, whereas other severe adverse events, such as sepsis, appear not to occur more frequently with saturation schemes. Current evidence suggests that saturation schemes are associated with a higher PCa detection rate compared to standard ones on initial PB in men with lower PSA levels or larger prostates, and on repeat PB. Since

  2. Evaluation of the ESUR PI-RADS scoring system for multiparametric MRI of the prostate with targeted MR/TRUS fusion-guided biopsy at 3.0 Tesla.

    PubMed

    Roethke, M C; Kuru, T H; Schultze, S; Tichy, D; Kopp-Schneider, A; Fenchel, M; Schlemmer, H-P; Hadaschik, B A

    2014-02-01

    To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy. Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann-Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated. In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42%) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/Specificity for the following thresholds were calculated: 85 %/73 % and 67 %/92 % for PI-RADS scores of 9 and 10, respectively; 85 %/60 % and 56 %/97 % for Likert scores of 3 and 4, respectively [corrected. The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score. • The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. • To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. • PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. • Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. • The PI-RADS scoring system may contribute to more effective prostate MRI.

  3. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.

    PubMed

    Gillies, Derek J; Gardi, Lori; De Silva, Tharindu; Zhao, Shuang-Ren; Fenster, Aaron

    2017-09-01

    During image-guided prostate biopsy, needles are targeted at tissues that are suspicious of cancer to obtain specimen for histological examination. Unfortunately, patient motion causes targeting errors when using an MR-transrectal ultrasound (TRUS) fusion approach to augment the conventional biopsy procedure. This study aims to develop an automatic motion correction algorithm approaching the frame rate of an ultrasound system to be used in fusion-based prostate biopsy systems. Two modes of operation have been investigated for the clinical implementation of the algorithm: motion compensation using a single user initiated correction performed prior to biopsy, and real-time continuous motion compensation performed automatically as a background process. Retrospective 2D and 3D TRUS patient images acquired prior to biopsy gun firing were registered using an intensity-based algorithm utilizing normalized cross-correlation and Powell's method for optimization. 2D and 3D images were downsampled and cropped to estimate the optimal amount of image information that would perform registrations quickly and accurately. The optimal search order during optimization was also analyzed to avoid local optima in the search space. Error in the algorithm was computed using target registration errors (TREs) from manually identified homologous fiducials in a clinical patient dataset. The algorithm was evaluated for real-time performance using the two different modes of clinical implementations by way of user initiated and continuous motion compensation methods on a tissue mimicking prostate phantom. After implementation in a TRUS-guided system with an image downsampling factor of 4, the proposed approach resulted in a mean ± std TRE and computation time of 1.6 ± 0.6 mm and 57 ± 20 ms respectively. The user initiated mode performed registrations with in-plane, out-of-plane, and roll motions computation times of 108 ± 38 ms, 60 ± 23 ms, and 89 ± 27 ms, respectively, and corresponding

  4. Identification of threshold prostate specific antigen levels to optimize the detection of clinically significant prostate cancer by magnetic resonance imaging/ultrasound fusion guided biopsy.

    PubMed

    Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A

    2014-12-01

    Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases

  5. Prostate atypia: does repeat biopsy detect clinically significant prostate cancer?

    PubMed

    Dorin, Ryan P; Wiener, Scott; Harris, Cory D; Wagner, Joseph R

    2015-05-01

    While the treatment pathway in response to benign or malignant prostate biopsies is well established, there is uncertainty regarding the risk of subsequently diagnosing prostate cancer when an initial diagnosis of prostate atypia is made. As such, we investigated the likelihood of a repeat biopsy diagnosing prostate cancer (PCa) in patients in which an initial biopsy diagnosed prostate atypia. We reviewed our prospectively maintained prostate biopsy database to identify patients who underwent a repeat prostate biopsy within one year of atypia (atypical small acinar proliferation; ASAP) diagnosis between November 1987 and March 2011. Patients with a history of PCa were excluded. Chart review identified patients who underwent radical prostatectomy (RP), radiotherapy (RT), or active surveillance (AS). For some analyses, patients were divided into two subgroups based on their date of service. Ten thousand seven hundred and twenty patients underwent 13,595 biopsies during November 1987-March 2011. Five hundred and sixty seven patients (5.3%) had ASAP on initial biopsy, and 287 (50.1%) of these patients underwent a repeat biopsy within one year. Of these, 122 (42.5%) were negative, 44 (15.3%) had atypia, 19 (6.6%) had prostatic intraepithelial neoplasia, and 102 (35.6%) contained PCa. Using modified Epstein's criteria, 27/53 (51%) patients with PCa on repeat biopsy were determined to have clinically significant tumors. 37 (36.3%) proceeded to RP, 25 (24.5%) underwent RT, and 40 (39.2%) received no immediate treatment. In patients who underwent surgery, Gleason grade on final pathology was upgraded in 11 (35.5%), and downgraded 1 (3.2%) patient. ASAP on initial biopsy was associated with a significant risk of PCa on repeat biopsy in patients who subsequently underwent definitive local therapy. Patients with ASAP should be counseled on the probability of harboring both clinically significant and insignificant prostate cancer. © 2015 Wiley Periodicals, Inc.

  6. Prebiopsy Multiparametric Magnetic Resonance Imaging for Prostate Cancer Diagnosis in Biopsy-naive Men with Suspected Prostate Cancer Based on Elevated Prostate-specific Antigen Values: Results from a Randomized Prospective Blinded Controlled Trial.

    PubMed

    Tonttila, Panu P; Lantto, Juha; Pääkkö, Eija; Piippo, Ulla; Kauppila, Saila; Lammentausta, Eveliina; Ohtonen, Pasi; Vaarala, Markku H

    2016-03-01

    Multiparametric magnetic resonance imaging (MP-MRI) may improve the detection of clinically significant prostate cancer (PCa). To compare MP-MRI transrectal ultrasound (TRUS)-fusion targeted biopsy with routine TRUS-guided random biopsy for overall and clinically significant PCa detection among patients with suspected PCa based on prostate-specific antigen (PSA) values. This institutional review board-approved, single-center, prospective, randomized controlled trial (April 2011 to December 2014) included 130 biopsy-naive patients referred for prostate biopsy based on PSA values (PSA <20 ng/ml or free-to-total PSA ratio ≤0.15 and PSA <10 ng/ml). Patients were randomized 1:1 to the MP-MRI or control group. Patients in the MP-MRI group underwent prebiopsy MP-MRI followed by 10- to 12-core TRUS-guided random biopsy and cognitive MRI/TRUS fusion targeted biopsy. The control group underwent TRUS-guided random biopsy alone. MP-MRI 3-T phased-array surface coil. The primary outcome was the number of patients with biopsy-proven PCa in the MP-MRI and control groups. Secondary outcome measures included the number of positive prostate biopsies and the proportion of clinically significant PCa in the MP-MRI and control groups. Between-group analyses were performed. Overall, 53 and 60 patients were evaluable in the MP-MRI and control groups, respectively. The overall PCa detection rate and the clinically significant cancer detection rate were similar between the MP-MRI and control groups, respectively (64% [34 of 53] vs 57% [34 of 60]; 7.5% difference [95% confidence interval (CI), -10 to 25], p=0.5, and 55% [29 of 53] vs 45% [27 of 60]; 9.7% difference [95% CI, -8.5 to 27], p=0.8). The PCa detection rate was higher than assumed during the planning of this single-center trial. MP-MRI/TRUS-fusion targeted biopsy did not improve PCa detection rate compared with TRUS-guided biopsy alone in patients with suspected PCa based on PSA values. In this randomized clinical trial

  7. Analysis of costs of transrectal prostate biopsy.

    PubMed

    Fandella, Andrea

    2011-01-01

    Literature reports mortality and morbidity data from prostatic carcinoma which permit a better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. The aim of this work is to quantify the overall cost of transrectal ultrasound biopsy of the prostate (TRUSB) and to assess the economic impact of current procedures for diagnosing prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 2008. The following cost factors were evaluated: personnel, materials, maintenance/depreciation of the equipment, energy consumption, and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide, and to consider them in the wider framework of the economic effectiveness of strategies for early diagnosis of cancer of the prostate. The overall cost of TRUSB (8 samples) was EUR 249,000, obtained by adding together the costs of: personnel (EUR 160,000); materials (EUR 59,000); equipment maintenance and depreciation (EUR 12,400); energy consumption (EUR0,1); hospital overheads (EUR 17,500). With extended or saturation biopsies the cost increases for the more time needed by pathologists and can be calculated as EUR 300,000. The literature review points out TRUSB as an invasive tool for diagnosing prostatic carcinoma, clinically and economically controversial. Post-mortem data report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity rate from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, have a good probability of being positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the detection by digital exploration and/or positive transrectal ultrasound. CONCLUSIONS. Despite the severe

  8. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    PubMed

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  9. Transperineal prostate biopsy with ECHO-MRI fusion. Biopsee system. Initial experience.

    PubMed

    Romero-Selas, E; Cuadros, V; Montáns, J; Sánchez, E; López-Alcorocho, J M; Gómez-Sancha, F

    2016-06-01

    The aim of this study is to present our initial experience with the stereotactic echo-MRI fusion system for diagnosing prostate cancer. Between September 2014 and January 2015, we performed 50 prostate biopsies using the stereotactic echo-MRI fusion system. The 3-Tesla multiparameter MR images were superimposed using this image fusion system on 3D echo images obtained with the Biopsee system for the exact locating of areas suspected of prostate cancer. The lesions were classified using the Prostate Imaging Report and Date System. We assessed a total of 50 patients, with a mean age of 63 years (range, 45-79), a mean prostate-specific antigen level of 8 ng/mL (range, 1.9-20) and a mean prostate volume of 52mL (range, 12-118). Prostate cancer was diagnosed in 69% of the patients and intraepithelial neoplasia in 6%. The results of the biopsy were negative for 24% of the patients. The results of the biopsy and MRI were in agreement for 62% of the patients; however, 46% also had a tumour outside of the suspicious lesion. We diagnosed 46% anterior tumours and 33% apical tumours. One patient had a haematuria, another had a haematoma and a third had acute urine retention. Multiparametric prostatic MRI helps identify prostate lesions suggestive of cancer. The Biopsee echo-MRI fusion system provides for guided biopsy and increases the diagnostic performance, reducing the false negatives of classical biopsies and increasing the diagnosis of anterior tumours. Transperineal access minimises the risk of prostatic infection and sepsis. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. MR-Guided Prostate Interventions

    PubMed Central

    Tempany, Clare; Straus, Sarah; Hata, Nobuhiko; Haker, Steven

    2009-01-01

    In this article the current issues of diagnosis and detection of prostate cancer are reviewed. The limitations for current techniques are highlighted and some possible solutions with MR imaging and MR-guided biopsy approaches are reviewed. There are several different biopsy approaches under investigation. These include transperineal open magnet approaches to closed-bore 1.5T transrectal biopsies. The imaging, image processing, and tracking methods are also discussed. In the arena of therapy, MR guidance has been used in conjunction with radiation methods, either brachytherapy or external delivery. The principles of the radiation treatment, the toxicities, and use of images are outlined. The future role of imaging and image-guided interventions lie with providing a noninvasive surrogate for cancer surveillance or monitoring treatment response. The shift to minimally invasive focal therapies has already begun and will be very exciting when MR-guided focused ultrasound surgery reaches its full potential. PMID:18219689

  11. Color Doppler quantitative measures to predict outcome of biopsies in prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strigari, Lidia; Marsella, Annelisa; Canitano, Stefano

    2008-11-15

    Purpose: The aim was to correlate the color Doppler flow activity pre- and postradiotherapy, using transrectal color Doppler ultrasonography (CDUS) and the 2 year positive biopsy rate after radiotherapy in patients with prostate cancer. Methods and materials: Analysis was carried out in 69 out of 160 patients who had undergone treatment with 3D-conformal radiotherapy (3D-CRT) to prostate and seminal vesicles. Patients were randomized to receive 80 Gy in 40 fractions in 8 weeks (arm A) and 62 Gy in 20 fractions in 5 weeks, 4 fractions per week (arm B). Color Doppler flow activity (CDFA) was evaluated calculating the vascularizationmore » index (VI), defined as the ratio between the colored and total pixels in the whole and peripheral prostate, delineated by a radiation oncologist on CDUS images, using EcoVasc a home-made software. The difference between the 2 year post- and pre-3D-CRT maximum VI (VI{sub max}), named {Delta}VI{sub max}, was calculated in the whole and peripheral prostate for each patient. Then, {Delta}VI{sub max} and the detected 2 year biopsy outcome were analyzed using the receiver operating characteristics (ROC) technique. Results: The VI{sub max} increased or decreased in patients with positive or negative biopsies, respectively, compared to the value before RT in both arms. The area under the ROC curve for {Delta}VI{sub max} in the whole and peripheral prostate is equal to 0.790 and 0.884, respectively. Conclusion: The {Delta}VI{sub max} index, comparing CDFA at 2 years compared to that before RT, allows the 2 year postradiotherapy positive biopsy rate to be predicted.« less

  12. Seminal epithelium in prostate biopsy can mimic malignant and premalignant prostatic lesions.

    PubMed

    Arista-Nasr, J; Trolle-Silva, A; Aguilar-Ayala, E; Martínez-Benítez, B

    2016-01-01

    In most prostate biopsies, the seminal epithelium is easily recognised because it meets characteristic histological criteria. However, some biopsies can mimic malignant or premalignant prostatic lesions. The aims of this study were to analyse the histological appearance of the biopsies that mimic adenocarcinomas or preneoplastic prostatic lesions, discuss the differential diagnosis and determine the frequency of seminal epithelia in prostate biopsies. We consecutively reviewed 500 prostate puncture biopsies obtained using the sextant method and selected those cases in which we observed seminal vesicle or ejaculatory duct epithelium. In the biopsies in which the seminal epithelium resembled malignant or premalignant lesions, immunohistochemical studies were conducted that included prostate-specific antigen and MUC6. The most important clinical data were recorded. Thirty-six (7.2%) biopsies showed seminal epithelium, and 7 of them (1.4%) resembled various prostate lesions, including high-grade prostatic intraepithelial neoplasia, atypical acinar proliferations, adenocarcinomas with papillary patterns and poorly differentiated carcinoma. The seminal epithelium resembled prostate lesions when the lipofuscin deposit, the perinuclear vacuoles or the nuclear pseudoinclusions were inconspicuous or missing. Five of the 7 biopsies showed mild to moderate cellular atypia with small and hyperchromatic nuclei, and only 2 showed cellular pleomorphism. The patients were alive and asymptomatic after an average of 6 years of progression. The seminal epithelium resembles prostatic intraepithelial neoplasia, atypical acinar proliferations and various types of prostatic adenocarcinomas in approximately 1.4% of prostate biopsies. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Age-Specific Prostate Specific Antigen Cutoffs for Guiding Biopsy Decision in Chinese Population

    PubMed Central

    Xu, Jianfeng; Jiang, Haowen; Ding, Qiang

    2013-01-01

    Background Age-specific prostate specific antigen (PSA) cutoffs for prostate biopsy have been widely used in the USA and European countries. However, the application of age-specific PSA remains poorly understood in China. Methods Between 2003 and 2012, 1,848 men over the age of 40, underwent prostate biopsy for prostate cancer (PCa) at Huashan Hospital, Shanghai, China. Clinical information and blood samples were collected prior to biopsy for each patient. Men were divided into three age groups (≤60, 61 to 80, and >80) for analyses. Digital rectal examination (DRE), transrectal ultrasound (prostate volume and nodule), total PSA (tPSA), and free PSA (fPSA) were also included in the analyses. Logistic regression was used to build the multi-variate model. Results Serum tPSA levels were age-dependent (P = 0.008), while %fPSA (P = 0.051) and PSAD (P = 0.284) were age-independent. At a specificity of 80%, the sensitivities for predicting PCa were 83%, 71% and 68% with tPSA cutoff values of 19.0 ng/mL (age≤60),21.0 ng/mL (age 61–80), and 23.0 ng/mL (age≥81). Also, sensitivities at the same tPSA levels were able to reach relatively high levels (70%–88%) for predicting high-grade PCa. Area (AUC) under the receive operating curves (ROCs) of tPSA, %fPSA, PSAD and multi-variate model were different in age groups. When predicting PCa, the AUC of tPSA, %fPSA, PSAD and multi-variate model were 0.90, 0.57, 0.93 and 0.87 respectively in men ≤60 yr; 0.82, 0.70, 0.88 and 0.86 respectively in men 61–80 yr; 0.79, 0.78, 0.87 and 0.88 respectively in men>80 yr. When predicting Gleason Score ≥7 or 8 PCa, there were no significant differences between AUCs of each variable. Conclusion Age-specific PSA cutoff values for prostate biopsy should be considered in the Chinese population. Indications for prostate biopsies (tPSA, %fPSA and PSAD) should be considered based on age in the Chinese population. PMID:23825670

  14. MR-guided prostate interventions.

    PubMed

    Tempany, Clare; Straus, Sarah; Hata, Nobuhiko; Haker, Steven

    2008-02-01

    In this article the current issues of diagnosis and detection of prostate cancer are reviewed. The limitations for current techniques are highlighted and some possible solutions with MR imaging and MR-guided biopsy approaches are reviewed. There are several different biopsy approaches under investigation. These include transperineal open magnet approaches to closed-bore 1.5T transrectal biopsies. The imaging, image processing, and tracking methods are also discussed. In the arena of therapy, MR guidance has been used in conjunction with radiation methods, either brachytherapy or external delivery. The principles of the radiation treatment, the toxicities, and use of images are outlined. The future role of imaging and image-guided interventions lie with providing a noninvasive surrogate for cancer surveillance or monitoring treatment response. The shift to minimally invasive focal therapies has already begun and will be very exciting when MR-guided focused ultrasound surgery reaches its full potential. (Copyright) 2008 Wiley-Liss, Inc.

  15. Magnetic resonance-guided prostate interventions.

    PubMed

    Haker, Steven J; Mulkern, Robert V; Roebuck, Joseph R; Barnes, Agnieska Szot; Dimaio, Simon; Hata, Nobuhiko; Tempany, Clare M C

    2005-10-01

    We review our experience using an open 0.5-T magnetic resonance (MR) interventional unit to guide procedures in the prostate. This system allows access to the patient and real-time MR imaging simultaneously and has made it possible to perform prostate biopsy and brachytherapy under MR guidance. We review MR imaging of the prostate and its use in targeted therapy, and describe our use of image processing methods such as image registration to further facilitate precise targeting. We describe current developments with a robot assist system being developed to aid radioactive seed placement.

  16. Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study.

    PubMed

    Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C

    2007-09-01

    To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.

  17. Rapid motion compensation for prostate biopsy using GPU.

    PubMed

    Shen, Feimo; Narayanan, Ramkrishnan; Suri, Jasjit S

    2008-01-01

    Image-guided procedures have become routine in medicine. Due to the nature of three-dimensional (3-D) structure of the target organs, two-dimensional (2-D) image acquisition is gradually being replaced by 3-D imaging. Specifically in the diagnosis of prostate cancer, biopsy can be performed using 3-D transrectal ultrasound (TRUS) image guidance. Because prostatic cancers are multifocal, it is crucial to accurately guide biopsy needles towards planned targets. Further the gland tends to move due to external physical disturbances, discomfort introduced by the procedure or intrinsic peristalsis. As a result the exact position of the gland must be rapidly updated so as to correspond with the originally acquired 3-D TRUS volume prior to biopsy planning. A graphics processing unit (GPU) is used in this study to compute rapid updates performing 3-D motion compensation via registration of the live 2-D image and the acquired 3-D TRUS volume. The parallel computational framework on the GPU is exploited resulting in mean compute times of 0.46 seconds for updating the position of a live 2-D buffer image containing 91,000 pixels. A 2x sub-sampling resulted in a further improvement to 0.19 seconds. With the increase in GPU multiprocessors and sub-sampling, we observe that real time motion compensation can be achieved.

  18. Ultrasound detection of prostatic calculi as a parameter to predict the appearance of hematospermia after a prostate biopsy.

    PubMed

    Dell'Atti, Lucio

    2017-01-01

    We evaluated the correlation between prostate calculi and hematospermia in patients undergoing prostate biopsy, and its impact on sexual activity of patients. A single-center prospective randomized study of 212 patients referred for transrectal ultrasound-guided prostate biopsy (TRUSBx) was performed. All patients were divided into two groups: Group A (GA), 106 patients with moderate/marked presence of prostatic calculi visualized by TRUS; Group B (GB), 106 patients with absence/scarce of prostatic calcifications. Patients were handed questionnaires to obtain a validated data on the duration and impact of hematospermia on sexual activity. The anxiety scores were recorded using a visual analogue scale. No significant difference was noted between the two groups when comparing age, preoperative PSA level, prostate volume, and biopsy number, except for digital rectal examination (DRE) findings. Post-biopsy results of patients included in GA revealed that the complication of hematospermia was present in 65.1%, while in GB was present in 39.7% (p<0.001). On multivariate analysis for identifying significant preoperative predictors of hematospermia, which included variables of age, PSA, prostate volume, and prostate cancer were not shown to be significant predictors of hematospermia, except DRE and prostate calculi (p<0.001). The mean anxiety score was 3.7±2.8 in GA and 2.3±1.9 in GB, respectively (p<0.001). Prostatic calculi are an independent predictive factor of severe hematospermia after TRUSBx on the basis of multivariate analysis, but don't affect the positive rate of prostate cancer. Patients should be adequately counselled before TRUSBx to avoid undue anxiety and alterations in sexual activity. Copyright® by the International Brazilian Journal of Urology.

  19. PCA3-based nomogram for predicting prostate cancer and high grade cancer on initial transrectal guided biopsy.

    PubMed

    Elshafei, Ahmed; Chevli, K Kent; Moussa, Ayman S; Kara, Onder; Chueh, Shih-Chieh; Walter, Peter; Hatem, Asmaa; Gao, Tianming; Jones, J Stephen; Duff, Michael

    2015-12-01

    To develop a validated prostate cancer antigen 3 (PCA3) based nomogram that predicts likelihood of overall prostate cancer (PCa) and intermediate/high grade prostate cancer (HGPCa) in men pursuing initial transrectal prostate biopsy (TRUS-PBx). Data were collected on 3,675 men with serum prostate specific antigen level (PSA) ≤ 20 ng/ml who underwent initial prostate biopsy with at least 10 cores sampling at time of the biopsy. Two logistic regression models were constructed to predict overall PCa and HGPCa incorporating age, race, family history (FH) of PCa, PSA at diagnosis, PCA3, total prostate volume (TPV), and digital rectal exam (DRE). One thousand six hundred twenty (44%) patients had biopsy confirmed PCa with 701 men (19.1%) showing HGPCa. Statistically significant predictors of overall PCa were age (P < 0.0001, OR. 1.51), PSA at diagnosis (P < 0.0001, OR.1.95), PCA3 (P < 0.0001, OR.3.06), TPV (P < 0.0001, OR.0.47), FH (P = 0.003, OR.1.32), and abnormal DRE (P = 0.001, OR. 1.32). While for HGPCa, predictors were age (P < 0.0001, OR.1.77), PSA (P < 0.0001, OR.2.73), PCA3 (P < 0.0001, OR.2.26), TPV (P < 0.0001, OR.0.4), and DRE (P < 0.0001, OR.1.53). Two nomograms were reconstructed for predicted overall PCa probability at time of initial biopsy with a concordance index of 0.742 (Fig. 1), and HGPCa with a concordance index of 0.768 (Fig. 2). Our internally validated initial biopsy PCA3 based nomogram is reconstructed based on a large dataset. The c-index indicates high predictive accuracy, especially for high grade PCa and improves the ability to predict biopsy outcomes. © 2015 Wiley Periodicals, Inc.

  20. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no

  1. Optical coherence elastography (OCE) as a method for identifying benign and malignant prostate biopsies

    NASA Astrophysics Data System (ADS)

    Li, Chunhui; Guan, Guangying; Ling, Yuting; Lang, Stephen; Wang, Ruikang K.; Huang, Zhihong; Nabi, Ghulam

    2015-03-01

    Objectives. Prostate cancer is the most frequently diagnosed malignancy in men. Digital rectal examination (DRE) - a known clinical tool based on alteration in the mechanical properties of tissues due to cancer has traditionally been used for screening prostate cancer. Essentially, DRE estimates relative stiffness of cancerous and normal prostate tissue. Optical coherence elastography (OCE) are new optical imaging techniques capable of providing cross-sectional imaging of tissue microstructure as well as elastogram in vivo and in real time. In this preliminary study, OCE was used in the setting of the human prostate biopsies ex vivo, and the images acquired were compared with those obtained using standard histopathologic methods. Methods. 120 prostate biopsies were obtained by TRUS guided needle biopsy procedures from 9 patients with clinically suspected cancer of the prostate. The biopsies were approximately 0.8mm in diameter and 12mm in length, and prepared in Formalin solution. Quantitative assessment of biopsy samples using OCE was obtained in kilopascals (kPa) before histopathologic evaluation. The results obtained from OCE and standard histopathologic evaluation were compared provided the cross-validation. Sensitivity, specificity, and positive and negative predictive values were calculated for OCE (histopathology was a reference standard). Results. OCE could provide quantitative elasticity properties of prostate biopsies within benign prostate tissue, prostatic intraepithelial neoplasia, atypical hyperplasia and malignant prostate cancer. Data analysed showed that the sensitivity and specificity of OCE for PCa detection were 1 and 0.91, respectively. PCa had significantly higher stiffness values compared to benign tissues, with a trend of increasing in stiffness with increasing of malignancy. Conclusions. Using OCE, microscopic resolution elastogram is promising in diagnosis of human prostatic diseases. Further studies using this technique to improve the

  2. Frequency of Unnecessarily Biopsies among Patients with Suspicion of Prostate Cancer in Syrian Men.

    PubMed

    Bachour, Dala-Maria; Chahin, Emil; Al-Fahoum, Sahar

    2015-01-01

    The prevalence of prostate cancer is considered high in many countries, and screening tests are very important in order to detect prostate cancer in its early stages; however false positivity with these screening tests means that a lot of patients undergo unnecessary biopsy, which is an invasive procedure, for the confirmatory test. The purpose of this study was to estimate the frequency of unnecessary biopsy cases in patients referred for prostate biopsy in one of the most important and overload cancer centers in Syria. Retrospective data for a period of four years between January 2009 and December 2012 were collected in Al- Bayrouni University Medical hospital in Damascus, Syria. The patients from whom data were collected were referred to our histopathological department because of elevated prostate specific antigen (PSA) serum or an abnormal digital rectal examination (DRE). All patients underwent prostatic TRUS-guided biopsies. Diagnosis of prostate cancer (PCa) or benign prostatic hyperplasia (BPH) was based on histopathological examination and prostate cancers cases were graded and scored according to the Gleason score system. For the 406 patients referred to biopsy, the mean±SD age was 58.4 ±23.3 years. The mean ± SD PSA level was 49.2±21.5 ng/ ml. Of the total we found 237 patients diagnosed with PCa (58. 4%), 166 patients with BPH (40.9%) and 3 cases were unable to be diagnosed (0.7%) because of biopsy collection errors. Our study shows that a high percentage of patients are undergoing unnecessary biopsy, which suggests that the performed screening tests had a high level of false positive and may need re-evaluation.

  3. Infection related hospitalizations after prostate biopsy in a statewide quality improvement collaborative.

    PubMed

    Womble, Paul R; Dixon, Maxwell W; Linsell, Susan M; Ye, Zaojun; Montie, James E; Lane, Brian R; Miller, David C; Burks, Frank N

    2014-06-01

    While transrectal prostate biopsy is the cornerstone of prostate cancer diagnosis, serious post-biopsy infectious complications are reported to be increasing. A better understanding of the true prevalence and microbiology of these events is needed to guide quality improvement in this area and ultimately better early detection practices. Using data from the MUSIC registry we identified all men who underwent transrectal prostate biopsy at 21 practices in Michigan from March 2012 to June 2013. Trained data abstractors recorded pertinent data including prophylactic antibiotics and all biopsy related hospitalizations. Claims data and followup telephone calls were used for validation. All men admitted to the hospital for an infectious complication were identified and their culture data were obtained. We then compared the frequency of infection related hospitalization rates across practices and according to antibiotic prophylaxis in concordance with AUA best practice recommendations. The overall 30-day hospital admission rate after prostate biopsy was 0.97%, ranging from 0% to 4.2% across 21 MUSIC practices. Of these hospital admissions 95% were for infectious complications and the majority of cultures identified fluoroquinolone resistant organisms. AUA concordant antibiotics were administered in 96.3% of biopsies. Patients on noncompliant antibiotic regimens were significantly more likely to be hospitalized for infectious complications (3.8% vs 0.89%, p=0.0026). Infection related hospitalizations occur in approximately 1% of men undergoing prostate biopsy in Michigan. Our findings suggest that many of these events could be avoided by implementing new protocols (eg culture specific or augmented antibiotic prophylaxis) that adhere to AUA best practice recommendations and address fluoroquinolone resistance. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Effect of Prostate Magnetic Resonance Imaging/Ultrasound Fusion-guided Biopsy on Radiation Treatment Recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, Aaron; Valle, Luca F.; Shankavaram, Uma

    Purpose: Targeted magnetic resonance imaging (MRI)/ultrasound fusion prostate biopsy (MRI-Bx) has recently been compared with the standard of care extended sextant ultrasound-guided prostate biopsy (SOC-Bx), with the former associated with an increased rate of detection of clinically significant prostate cancer. The present study sought to determine the influence of MRI-Bx on radiation therapy and androgen deprivation therapy (ADT) recommendations. Methods and Materials: All patients who had received radiation treatment and had undergone SOC-Bx and MRI-Bx at our institution were included. Using the clinical T stage, pretreatment prostate-specific antigen, and Gleason score, patients were categorized into National Comprehensive Cancer Network riskmore » groups and radiation treatment or ADT recommendations assigned. Intensification of the recommended treatment after multiparametric MRI, SOC-Bx, and MRI-Bx was evaluated. Results: From January 2008 to January 2016, 73 patients received radiation therapy at our institution after undergoing a simultaneous SOC-Bx and MRI-Bx (n=47 with previous SOC-Bx). Repeat SOC-Bx and MRI-Bx resulted in frequent upgrading compared with previous SOC-Bx (Gleason score 7, 6.7% vs 44.6%; P<.001; Gleason score 8-10, 2.1% vs 38%; P<.001). MRI-Bx increased the proportion of patients classified as very high risk from 24.7% to 41.1% (P=.027). Compared with SOC-Bx alone, including the MRI-Bx findings resulted in a greater percentage of pathologically positive cores (mean 37% vs 44%). Incorporation of multiparametric MRI and MRI-Bx results increased the recommended use and duration of ADT (duration increased in 28 of 73 patients and ADT was added for 8 of 73 patients). Conclusions: In patients referred for radiation treatment, MRI-Bx resulted in an increase in the percentage of positive cores, Gleason score, and risk grouping. The benefit of treatment intensification in accordance with the MRI-Bx findings is unknown.« less

  5. Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?

    PubMed

    Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun

    2015-02-01

    To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.

  6. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Peter R., E-mail: pmarti46@uwo.ca; Cool, Derek W.; Romagnoli, Cesare

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiologymore » resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for

  7. Segmentation of prostate biopsy needles in transrectal ultrasound images

    NASA Astrophysics Data System (ADS)

    Krefting, Dagmar; Haupt, Barbara; Tolxdorff, Thomas; Kempkensteffen, Carsten; Miller, Kurt

    2007-03-01

    Prostate cancer is the most common cancer in men. Tissue extraction at different locations (biopsy) is the gold-standard for diagnosis of prostate cancer. These biopsies are commonly guided by transrectal ultrasound imaging (TRUS). Exact location of the extracted tissue within the gland is desired for more specific diagnosis and provides better therapy planning. While the orientation and the position of the needle within clinical TRUS image are limited, the appearing length and visibility of the needle varies strongly. Marker lines are present and tissue inhomogeneities and deflection artefacts may appear. Simple intensity, gradient oder edge-detecting based segmentation methods fail. Therefore a multivariate statistical classificator is implemented. The independent feature model is built by supervised learning using a set of manually segmented needles. The feature space is spanned by common binary object features as size and eccentricity as well as imaging-system dependent features like distance and orientation relative to the marker line. The object extraction is done by multi-step binarization of the region of interest. The ROI is automatically determined at the beginning of the segmentation and marker lines are removed from the images. The segmentation itself is realized by scale-invariant classification using maximum likelihood estimation and Mahalanobis distance as discriminator. The technique presented here could be successfully applied in 94% of 1835 TRUS images from 30 tissue extractions. It provides a robust method for biopsy needle localization in clinical prostate biopsy TRUS images.

  8. [Intravesical active prostate bleeding diagnosed in B-mode ultrasound].

    PubMed

    Kirchgesner, T; Danse, E; Tombal, B

    2013-09-01

    Hematuria is one of the most frequent minor complications after prostatic biopsy. We would like to report the case of a 68-year-old patient with massive hematuria after prostatic biopsy and intravesical active prostate bleeding diagnosed in B-mode ultrasonography. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  9. Image-guided diagnosis of prostate cancer can increase detection of tumors

    Cancer.gov

    In the largest prospective study to date of image-guided technology for identifying suspicious regions of the prostate to biopsy, researchers compared the ability of this technology to detect high-risk prostate cancer with that of the current standard of

  10. Prostate-specific antigen increase during dutasteride to indicate the need for prostate biopsy: influence of prostatic inflammation.

    PubMed

    Sciarra, Alessandro; Maggi, Martina; Fasulo, Andrea; Salciccia, Stefano; Gentile, Vincenzo; Cattarino, Susanna; Gentilucci, Alessandro

    2017-08-01

    The aim of this study was to analyze the significance of an increase in total prostate-specific antigen (PSA) serum levels despite dutasteride treatment as a predictor of prostate cancer (PC) at biopsy. We focused our attention on the rate of the first PSA increase and on the influence of prostatic inflammation. From 2011 to 2016, 365 men with a previous negative prostate biopsy and persistent elevated PSA levels received dutasteride treatment. The population was followed for a range of 12-48 months. One hundred twelve cases with a confirmed PSA increase >0.5 ng/ml over the nadir value during the follow-up were included in Group A and underwent a new prostate biopsy. In Group A, the PSA increase was associated with PC at the re-biopsy in 66% of cases. The percentage of PSA reduction after 6 months of treatment was not a significant indicator of the risk for PC. The distribution of inflammatory infiltrates significantly (p<00.01) varied from positive to negative prostate biopsies. The relative risk for PC at biopsy significantly increased according to PSA level during dutasteride. Treatment with dutasteride can help to analyze PSA kinetic. A persistent prostatic inflammation is a factor able to reduce the performance of PSA kinetic during dutasteride treatment.

  11. Initial Experience Performing In-office Ultrasound-guided Transperineal Prostate Biopsy Under Local Anesthesia Using the PrecisionPoint Transperineal Access System.

    PubMed

    Meyer, Alexa R; Joice, Gregory A; Schwen, Zeyad R; Partin, Alan W; Allaf, Mohamad E; Gorin, Michael A

    2018-05-01

    To describe our procedural technique and initial outcomes performing in-office transperineal prostate biopsies using the PrecisionPoint Transperineal Access System (Perineologic, Cumberland, MD). Following institutional review board approval, we retrospectively reviewed the records of men who underwent an in-office transperineal prostate biopsy using the PrecisionPoint device. Records were reviewed for baseline characteristics, biopsy results, and postbiopsy complications. Between January 4, 2017 and August 23, 2017, 43 men underwent an in-office transperineal prostate biopsy using the PrecisionPoint Transperineal Access System. Patients had a median serum prostate specific antigen level of 6.1 ng/mL (range 0.8-32.9). Of the 43 biopsies, 12 (27.9%) were performed for active surveillance of low-risk prostate cancer and 31 (72.1%) were performed for cancer screening. Overall, 21 (48.8%) men were found to have prostate cancer. Among those on active surveillance, cancer was detected in 8 of 12 (66.7%) patients, with 2 of 12 (16.7%) found to have Gleason ≥3 + 4 = 7 prostate cancer. Additionally, cancer was detected in 13 of 31 (41.9%) patients undergoing a biopsy for prostate cancer screening, with 5 (16.1%) found to have Gleason ≥3 + 4 = 7 disease. In total, 3 (7.0%) patients experienced a postbiopsy complication: 2 (4.7%) with urinary retention and 1 (2.3%) with gross hematuria requiring catheterization. No patient experienced an infectious complication despite omission of periprocedural antibiotics in all cases. The PrecisionPoint device allowed for the successful performance of in-office transperineal prostate biopsies under local anesthesia without the need for periprocedural antibiotics. We observed an acceptable cancer detection rate with no infectious complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. [Determination of the 120-day post prostatic biopsy mortality rate].

    PubMed

    Canat, G A; Duclos, A; Couray-Targe, S; Schott, A-M; Polazzi, S; Scoazec, J-Y; Berger, F; Perrin, P

    2014-06-01

    Concerning death-rates were reported following prostate biopsy but the lack of contexts in which event occurred makes it difficult to take any position. Therefore, we aimed to determine the 120-day post-biopsy mortality rate. Between 2000 and 2011, 8804 men underwent prostate biopsy in the hospice civils de Lyon. We studied retrospectively, the mortality rate after each of the 11,816 procedures. Biopsies imputability was assessed by examining all medical records. Dates of death were extracted from our local patient management database, which is updated trimestrially with death notifications from the French National Institute for Statistics and Economic Studies. In our study 42 deaths occurred within 120days after 11,816 prostate biopsies (0.36%). Of the 42 records: 9 were lost to follow-up, 3 had no identifiable cause of death, 28 had an intercurrent event ruling out prostate biopsy as a cause of death. Only 2 deaths could be linked to biopsy. We reported at most 2 deaths possibly related to prostate biopsy over 11,816 procedures (0.02%). We confirmed the fact that prostate biopsies can be lethal but this rare outcome should not be considered as an argument against prostate screening given the circumstances in which it occurs. 5. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  13. [Ecology and fluoroquinolon resistance profiles in febrile urinary tract infections (FUTI) after prostate needle biopsy: A retrospective study in 466 biopsies].

    PubMed

    Duboureau, H; Achkar, K; Stephan, R; Schmit, J L; Saint, F

    2017-05-01

    The biopsies of prostate are the reference examination to assert the diagnosis of prostate cancer. Even if the urinary infectious complications are rare thanks to the systematic oral antibiotic prophylaxis, they may still be serious. The SPILF (Society of Infectious Pathology and French language) published in 2014, an important increase of the resistances in fluoroquinolones for Escherichia coli (3 to 25%), whereas this is the most bacterium frequently found in the urinary infections (70-80%). The objectives of this study were to estimate the indicence of the febrile urinary tract infections after prostate needle biopsy and to define the ecology and the profile of E. coli's resistance. A total of 466 transrectal ultrasound-guided needle prostate biopsy were included in the study from 2012 to 2015. All the patients were taken care according to the recommendations of the AFU (Ouzzane et al., 2011). We estimated, for all the inclusive patients, if they had presented a clinic sign of urinary infection like fever or burning which suggestive of an urinary infection, and having a urines and blood culture, in the next 30 days the realization of the medical exam. Among 466 realized biopsies, seven patients developed a febril urinary tract infection (1.5%) [prostatitis (n=6), orchitis (n=1)]. Five infections to E. coli were identified; two were resistant for fluoroquinolones (40%). No germ was able to be identified for two patients. The infectious complications post-biopsy of prostate are rare (1.5%). E. coli is the germ most frequently identified with 40% of resistance with fluoroquinolones. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Prostate specific antigen velocity does not aid prostate cancer detection in men with prior negative biopsy.

    PubMed

    Vickers, Andrew J; Wolters, Tineke; Savage, Caroline J; Cronin, Angel M; O'Brien, M Frank; Roobol, Monique J; Aus, Gunnar; Scardino, Peter T; Hugosson, Jonas; Schröder, Fritz H; Lilja, Hans

    2010-09-01

    Prostate specific antigen velocity has been proposed as a marker to aid in prostate cancer detection. We determined whether prostate specific antigen velocity could predict repeat biopsy results in men with persistently increased prostate specific antigen after initial negative biopsy. We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer and who underwent 1 or more subsequent prostate biopsies after an initial negative finding. We evaluated whether prostate specific antigen velocity improved predictive accuracy beyond that of prostate specific antigen alone. Of the 2,579 repeat biopsies 363 (14%) were positive for prostate cancer, of which 44 (1.7%) were high grade (Gleason score 7 or greater). Prostate specific antigen velocity was statistically associated with cancer risk but had low predictive accuracy (AUC 0.55, p <0.001). There was some evidence that prostate specific antigen velocity improved AUC compared to prostate specific antigen for high grade cancer. However, the small increase in risk associated with high prostate specific antigen velocity (from 1.7% to 2.8% as velocity increased from 0 to 1 ng/ml per year) had questionable clinical relevance. Men with prior negative biopsy are at lower risk for prostate cancer at subsequent biopsies with high grade disease particularly rare. We found little evidence to support prostate specific antigen velocity to aid in decisions about repeat biopsy for prostate cancer. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Prostate-specific antigen velocity is not better than total prostate-specific antigen in predicting prostate biopsy diagnosis.

    PubMed

    Gorday, William; Sadrzadeh, Hossein; de Koning, Lawrence; Naugler, Christopher T

    2015-12-01

    1.) Identify whether prostate-specific antigen velocity improves the ability to predict prostate biopsy diagnosis. 2.) Test whether there is an increase in the predictive capability of models when Gleason 7 prostate cancers are separated into a 3+4 and a 4+3 group. Calgary Laboratory Services' Clinical Laboratory Information System was searched for prostate biopsies reported between January 1, 2009 and December 31, 2013. Total prostate-specific antigen tests were recorded for each patient from January 1, 2007 to the most recent test before their recorded prostate biopsy. The data set was divided into the following three groups for comparison; benign, all prostate cancer and Gleason 7-10. The Gleason grade 7-10 group was further divided into 4+3 and 3+4 Gleason 7 prostate cancers. Prostate-specific antigen velocity was calculated using four different methods found in the literature. Receiver operator curves were used to assess operational characteristics of the tests. 4622 men between the ages of 40-89 with a prostate biopsy were included for analysis. Combining prostate-specific antigen velocity with total prostate-specific antigen (AUC=0.570-0.712) resulted in small non-statistically significant changes to the area under the curve compared to the area under the curve of total prostate-specific antigen alone (AUC=0.572-0.699). There were marked increases in the area under curves when 3+4 and 4+3 Gleason 7 cancers were separated. Prostate-specific antigen velocity does not add predictive value for prostate biopsy diagnosis. The clinical significance of the prostate specific antigen test can be improved by separating Gleason 7 prostate cancers into a 3+4 and 4+3 group. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Prophylactic antibiotics reduce sepsis after biopsy of the prostate.

    PubMed

    Hayatzaki, Khalilullah; Menne, Sveinar; Nielsen, Karsten

    2014-11-01

    Prostate cancer is the most common form of cancer in Danish men, and the incidence is rising. The diag-nosis is made by transrectal prostate biopsy guided by ultrasound. This procedure has several complications, the most severe being sepsis. In our department, this is sought prevented by administering the prophylactic antibiotics metronidazol and ciprofloxacin. This study examined the rate of sepsis in patients who had the procedure performed at our department. The electronic patient records of all patients who had transrectal ultrasound of the prostate with biopsies performed at the Department of Urology at Naestved Hospital in the period from 1 May 2009 to 31 May 2011 were examined, and all admissions to our department (or any department in the same region) due to sepsis within two weeks of the procedure were registered. A total of 438 patients had the procedure performed, some multiple times, which resulted in a total of 511 procedures. In all, four patients were later admitted due to sepsis, corresponding to 0.91%. Three of the patients had positive blood and urine cultures in which Escherichia coli resistant to ciprofloxacin were found, the last had been prescribed antibiotics by a general practitioner the previous day, and no bacteria could be cultured. The frequency of sepsis after transrectal needle biopsies from the prostate at our department was found to be below 1% in this study, which is comparable to international findings. Most of the cases of sepsis were related to ciprofloxacin-resistant bacteria. Further randomised studies are needed to investigate the ideal prophylactic regime. not relevant. not relevant.

  17. Assessment and clinical factors associated with pain in patients undergoing transrectal prostate biopsy.

    PubMed

    Gómez-Gómez, E; Ramírez, M; Gómez-Ferrer, A; Rubio-Briones, J; Iborra, I; J Carrasco-Valiente; Campos, J P; Ruiz-García, J; Requena-Tapia, M J; Solsona, E

    2015-09-01

    To quantify the degree of pain experienced by patients who undergo ultrasound-guided transrectal prostate biopsy in standard clinical practice and assess the clinical factors associated with increased pain. Analysis of a multicenter series of patients with prostate biopsy according to standard clinical practice. The biopsy was performed transrectally with a protocol of local anesthesia on the posterolateral nerve bundle. The pain was assessed at 20minutes into the procedure using the visual analog scale (0-10). The degree of pain was analyzed, and the association was studied using a univariate/multivariate analysis of selected clinical variables and the degree of pain. A total of 1188 patients with a median age of 64 years were analyzed. Thirty percent of the biopsies were diagnosed with a tumor. The median pain score was 2, with 65% of the patients reporting a pain score ≤2. The multivariate analysis showed that the prostate volume (RR, 1.34; 95% CI 1.01-1.77; P=.04), having a previous biopsy (RR, 2.25; 95% CI 1.44-3.52; P<.01), age (RR, .63; 95% CI .47-.85; P<.01) and feel palpation (RR, 1.95; 95% CI 1.28-2.96; P<.01) were factors independently associated with greater pain during the procedure. Transrectal biopsy with local anesthesia is a relatively painless technique. Factors such as age, a previous biopsy, pain on being touched and prostate volume were associated with the presence of greater pain during the procedure. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. 1.5-Tesla Multiparametric-Magnetic Resonance Imaging for the detection of clinically significant prostate cancer.

    PubMed

    Popita, Cristian; Popita, Anca Raluca; Sitar-Taut, Adela; Petrut, Bogdan; Fetica, Bogdan; Coman, Ioan

    2017-01-01

    Multiparametric-magnetic resonance imaging (mp-MRI) is the main imaging modality used for prostate cancer detection. The aim of this study is to evaluate the diagnostic performance of mp-MRI at 1.5-Tesla (1.5-T) for the detection of clinically significant prostate cancer. In this ethical board approved prospective study, 39 patients with suspected prostate cancer were included. Patients with a history of positive prostate biopsy and patients treated for prostate cancer were excluded. All patients were examined at 1.5-T MRI, before standard transrectal ultrasonography-guided biopsy. The overall sensitivity, specificity, positive predictive value and negative predictive value for mp-MRI were 100%, 73.68%, 80% and 100%, respectively. Our results showed that 1.5 T mp-MRI has a high sensitivity for detection of clinically significant prostate cancer and high negative predictive value in order to rule out significant disease.

  19. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    PubMed

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Three-dimensional nonrigid landmark-based magnetic resonance to transrectal ultrasound registration for image-guided prostate biopsy.

    PubMed

    Sun, Yue; Qiu, Wu; Yuan, Jing; Romagnoli, Cesare; Fenster, Aaron

    2015-04-01

    Registration of three-dimensional (3-D) magnetic resonance (MR) to 3-D transrectal ultrasound (TRUS) prostate images is an important step in the planning and guidance of 3-D TRUS guided prostate biopsy. In order to accurately and efficiently perform the registration, a nonrigid landmark-based registration method is required to account for the different deformations of the prostate when using these two modalities. We describe a nonrigid landmark-based method for registration of 3-D TRUS to MR prostate images. The landmark-based registration method first makes use of an initial rigid registration of 3-D MR to 3-D TRUS images using six manually placed approximately corresponding landmarks in each image. Following manual initialization, the two prostate surfaces are segmented from 3-D MR and TRUS images and then nonrigidly registered using the following steps: (1) rotationally reslicing corresponding segmented prostate surfaces from both 3-D MR and TRUS images around a specified axis, (2) an approach to find point correspondences on the surfaces of the segmented surfaces, and (3) deformation of the surface of the prostate in the MR image to match the surface of the prostate in the 3-D TRUS image and the interior using a thin-plate spline algorithm. The registration accuracy was evaluated using 17 patient prostate MR and 3-D TRUS images by measuring the target registration error (TRE). Experimental results showed that the proposed method yielded an overall mean TRE of [Formula: see text] for the rigid registration and [Formula: see text] for the nonrigid registration, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm. A landmark-based nonrigid 3-D MR-TRUS registration approach is proposed, which takes into account the correspondences on the prostate surface, inside the prostate, as well as the centroid of the prostate. Experimental results indicate that the proposed method yields clinically sufficient accuracy.

  1. Detection and clearance of prostate cells subsequent to ultrasound-guided needle biopsy as determined by multiplex nested reverse transcription polymerase chain reaction assay.

    PubMed

    Price, D K; Clontz, D R; Woodard, W L; Kaufman, J S; Daniels, J M; Stolzenberg, S J; Teigland, C M

    1998-08-01

    To determine if circulating prostate cells are detectable subsequent to transrectal ultrasound (TRUS)-guided biopsy, and if so, whether cells remain in circulation for up to 4 weeks. Blood samples were drawn from 90 patients with elevated serum prostate-specific antigen (PSA) levels and/or abnormal digital rectal examination. Two samples were drawn from all patients immediately prior to TRUS and 30 minutes postbiopsy. Blood samples were also obtained 1 week postbiopsy from 83 patients, and 1 month postbiopsy from 61 patients. Multiplex nested reverse transcription polymerase chain reaction assay (RT-PCR) for PSA and prostate-specific membrane antigen (PSM) was performed on total ribonucleic acid (RNA) from each sample. Results were reported as positive if at least one of the targets was detected. Of 45 patients with biopsy-proven adenocarcinoma, 22 were RT-PCR positive prebiopsy and all remained positive 30 minutes postbiopsy. Of 23 patients with adenocarcinoma who were RT-PCR negative prebiopsy, 5 (22%) converted to positive 30 minutes postbiopsy (P < 0.001). Four of these 5 patients returned to negative after 1 week or 1 month. Of 45 patients without cancer at biopsy, 32 were RT-PCR negative prebiopsy and 6 (19%) converted to positive 30 minutes postbiopsy (P < 0.001). Although four of six available samples were still positive at 1 week, all four samples available 1 month postbiopsy were negative. Detection of circulating prostate cells subsequent to biopsy occurred in 11 of 55 (20%) previously RT-PCR negative patients, a proportion twice that reported in the literature. We attribute this higher proportion to the simultaneous detection of PSA and PSM mRNA in our multiplex assay. Conversion rates were similar in patients regardless of biopsy result. Testing of serial postbiopsy blood demonstrates clearing of these cells by 4 weeks in most patients.

  2. Liquid biopsy: ready to guide therapy in advanced prostate cancer?

    PubMed

    Hegemann, Miriam; Stenzl, Arnulf; Bedke, Jens; Chi, Kim N; Black, Peter C; Todenhöfer, Tilman

    2016-12-01

    The identification of molecular markers associated with response to specific therapy is a key step for the implementation of personalised treatment strategies in patients with metastatic prostate cancer. Only in a low proportion of patients biopsies of metastatic tissue are performed. Circulating tumour cells (CTC), cell-free DNA (cfDNA) and RNA offer the potential for non-invasive characterisation of disease and molecular stratification of patients. Furthermore, a 'liquid biopsy' approach permits longitudinal assessments, allowing sequential monitoring of response and progression and the potential to alter therapy based on observed molecular changes. In prostate cancer, CTC enumeration using the CellSearch© platform correlates with survival. Recent studies on the presence of androgen receptor (AR) variants in CTC have shown that such molecular characterisation of CTC provides a potential for identifying patients with resistance to agents that inhibit the androgen signalling axis, such as abiraterone and enzalutamide. New developments in CTC isolation, as well as in vitro and in vivo analysis of CTC will further promote the use of CTC as a tool for retrieving molecular information from advanced tumours in order to identify mechanisms of therapy resistance. In addition to CTC, nucleic acids such as RNA and cfDNA released by tumour cells into the peripheral blood contain important information on transcriptomic and genomic alterations in the tumours. Initial studies have shown that genomic alterations of the AR and other genes detected in CTC or cfDNA of patients with castration-resistant prostate cancer correlate with treatment outcomes to enzalutamide and abiraterone. Due to recent developments in high-throughput analysis techniques, it is likely that CTC, cfDNA and RNA will be an important component of personalised treatment strategies in the future. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  3. Early prostate cancer antigen expression in predicting presence of prostate cancer in men with histologically negative biopsies.

    PubMed

    Hansel, D E; DeMarzo, A M; Platz, E A; Jadallah, S; Hicks, J; Epstein, J I; Partin, A W; Netto, G J

    2007-05-01

    Early prostate cancer antigen is a nuclear matrix protein that was recently shown to be expressed in prostate adenocarcinoma and adjacent benign tissue. Previous studies have demonstrated early prostate cancer antigen expression in benign prostate tissue up to 5 years before a diagnosis of prostate carcinoma, suggesting that early prostate cancer antigen could be used as a potential predictive marker. We evaluated early prostate cancer antigen expression by immunohistochemistry using a polyclonal antibody (Onconome Inc., Seattle, Washington) on benign biopsies from 98 patients. Biopsies were obtained from 4 groups that included 39 patients with first time negative biopsy (group 1), 24 patients with persistently negative biopsies (group 2), 8 patients with initially negative biopsies who were subsequently diagnosed with prostate carcinoma (group 3) and negative biopsies obtained from 27 cases where other concurrent biopsies contained prostate carcinoma (group 4). Early prostate cancer antigen staining was assessed by 2 of the authors who were blind to the group of the examined sections. Staining intensity (range 0 to 3) and extent (range 1 to 3) scores were assigned. The presence of intensity 3 staining in any of the blocks of a biopsy specimen was considered as positive for early prostate cancer antigen for the primary outcome in the statistical analysis. In addition, as secondary outcomes we evaluated the data using the proportion of blocks with intensity 3 early prostate cancer antigen staining, the mean of the product of staining intensity and staining extent of all blocks within a biopsy, and the mean of the product of intensity 3 staining and extent. Primary outcome analysis revealed the proportion of early prostate cancer antigen positivity to be highest in group 3 (6 of 8, 75%) and lowest in group 2 (7 of 24, 29%, p=0.04 for differences among groups). A relatively higher than expected proportion of early prostate cancer antigen positivity was present in

  4. Outcome and safety of transrectal US-guided percutaneous cryotherapy for localized prostate cancer.

    PubMed

    Saliken, J C; Donnelly, B J; Brasher, P; Ali-Ridha, N; Ernst, S; Robinson, J

    1999-02-01

    To assess the effectiveness and safety of ultrasound (US)-guided cryotherapy as a primary treatment for localized prostate cancer. A prospective study of percutaneous transrectal US (TRUS)-guided cryotherapy was performed on 71 patients with T1-T3, N0, M0 prostatic cancer: 10 patients underwent two or more procedures. All cases were newly diagnosed and patients had no previous treatment for cancer. For all patients, TRUS biopsies were performed at 5-6 months. Patients were monitored at 6 weeks; 3, 6, 9, and 12 months; and twice yearly thereafter for prostate specific antigen (PSA) levels, complications, and clinical evidence of residual disease. Follow-up from 10 to 36 months was available for 70 of 71 patients; one patient died of unrelated disease. Initially, 10 of 69 patients had positive postcryotherapy biopsy results. After repeated treatment, nine of these 10 patients had negative biopsy results and one patient had no follow-up. Overall, 68 of 69 patients had negative biopsy results. At 1 year, 43 of 64 (67%) had an undetectable PSA level. Two patients had proven metastases. Complications include three cases with urethral sloughing requiring transurethral resection of the prostate (TURP). One patient had orchitis. Two patients had persistent incontinence, one as the result of a TURP. There was no death, acute serious morbidity, or fistula formation. Impotence was universal at 6 months, but many patients demonstrated late recovery. Cryoablation is an imaging-guided percutaneous intervention for prostate cancer that can safely yield disease-free status in a high percentage of patients with localized disease.

  5. Development and preliminary evaluation of an ultrasonic motor actuated needle guide for 3T MRI-guided transperineal prostate interventions

    NASA Astrophysics Data System (ADS)

    Song, Sang-Eun; Tokuda, Junichi; Tuncali, Kemal; Tempany, Clare; Hata, Nobuhiko

    2012-02-01

    Image guided prostate interventions have been accelerated by Magnetic Resonance Imaging (MRI) and robotic technologies in the past few years. However, transrectal ultrasound (TRUS) guided procedure still remains as vast majority in clinical practice due to engineering and clinical complexity of the MRI-guided robotic interventions. Subsequently, great advantages and increasing availability of MRI have not been utilized at its maximum capacity in clinic. To benefit patients from the advantages of MRI, we developed an MRI-compatible motorized needle guide device "Smart Template" that resembles a conventional prostate template to perform MRI-guided prostate interventions with minimal changes in the clinical procedure. The requirements and specifications of the Smart Template were identified from our latest MRI-guided intervention system that has been clinically used in manual mode for prostate biopsy. Smart Template consists of vertical and horizontal crossbars that are driven by two ultrasonic motors via timing-belt and mitergear transmissions. Navigation software that controls the crossbar position to provide needle insertion positions was also developed. The software can be operated independently or interactively with an open-source navigation software, 3D Slicer, that has been developed for prostate intervention. As preliminary evaluation, MRI distortion and SNR test were conducted. Significant MRI distortion was found close to the threaded brass alloy components of the template. However, the affected volume was limited outside the clinical region of interest. SNR values over routine MRI scan sequences for prostate biopsy indicated insignificant image degradation during the presence of the robotic system and actuation of the ultrasonic motors.

  6. Computerized transrectal ultrasound (C-TRUS) of the prostate: detection of cancer in patients with multiple negative systematic random biopsies.

    PubMed

    Loch, Tillmann

    2007-08-01

    This study was designed to compare the diagnostic yield of computerized transrectal ultrasound (C-TRUS) guided biopsies in the detection of prostate cancer in a group of men with a history of multiple systematic random biopsies with no prior evidence of prostate cancer. The question was asked: Can we detect cancer by C-TRUS that has been overlooked by multiple systematic biopsies? The entrance criteria for this study were prior negative systematic random biopsies regardless of number of biopsy sessions or number of individual biopsy cores. Serial static TRUS images were evaluated by C-TRUS, which assessed signal information independent of visual gray scale. Five C-TRUS algorithms were utilized to evaluate the information of the ultrasound signal. Interpretation of the results were documented and the most suspicious regions marked by C-TRUS were biopsied by guiding the needle to the marked location. Five hundred and forty men were biopsied because of an elevated PSA or abnormal digital rectal exam. 132 had a history of prior negative systematic random biopsies (1-7 sessions, median: 2 and between 6 and 72 individual prostate biopsies, median: 12 cores). Additionally, a diagnostic TUR-P of the prostate with benign result was performed in four patients. The PSA ranged from 3.1-36 ng/ml with a median of 9.01 ng/ml. The prostate volume ranged from 6-203 ml with a median of 42 ml. Of the 132 patients with prior negative systematic random biopsies, cancer was found in 66 (50%) by C-TRUS targeted biopsies. In this group the median number of negative biopsy sessions was two and a median of 12 biopsy cores were performed. From literature we would expect a cancer detection rate in this group with systematic biopsies of approximately 7%. We only found five carcinomas with a Gleason Score (GS) of 5, 25 with GS 6, 22 with GS 7, 8 with GS 8 and even 7 with GS 9. The results of this prospective clinical trail indicates that the additional use of the C-TRUS identifies clinical

  7. External validation of a PCA-3-based nomogram for predicting prostate cancer and high-grade cancer on initial prostate biopsy.

    PubMed

    Greene, Daniel J; Elshafei, Ahmed; Nyame, Yaw A; Kara, Onder; Malkoc, Ercan; Gao, Tianming; Jones, J Stephen

    2016-08-01

    The aim of this study was to externally validate a previously developed PCA3-based nomogram for the prediction of prostate cancer (PCa) and high-grade (intermediate and/or high-grade) prostate cancer (HGPCa) at the time of initial prostate biopsy. A retrospective review was performed on a cohort of 336 men from a large urban academic medical center. All men had serum PSA <20 ng/ml and underwent initial transrectal ultrasound-guided prostate biopsy with at least 10 cores sampling for suspicious exam and/or elevated PSA. Covariates were collected for the nomogram and included age, ethnicity, family history (FH) of PCa, PSA at diagnosis, PCA3, total prostate volume (TPV), and abnormal finding on digital rectal exam (DRE). These variables were used to test the accuracy (concordance index) and calibration of a previously published PCA3 nomogram. Biopsy confirms PCa and HGPCa in 51.0% and 30.4% of validation patients, respectively. This differed from the original cohort in that it had significantly more PCa and HGPCA (51% vs. 44%, P = 0.019; and 30.4% vs. 19.1%, P < 0.001). Despite the differences in PCa detection the concordance index was 75% and 77% for overall PCa and HGPCa, respectively. Calibration for overall PCa was good. This represents the first external validation of a PCA3-based prostate cancer predictive nomogram in a North American population. Prostate 76:1019-1023, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. Association of quantitative magnetic resonance imaging parameters with histological findings from MRI/ultrasound fusion prostate biopsy.

    PubMed

    Dianat, Seyed Saeid; Carter, H Ballentine; Schaeffer, Edward M; Hamper, Ulrik M; Epstein, Jonathan I; Macura, Katarzyna J

    2015-10-01

    Purpose of this pilot study was to correlate quantitative parameters derived from the multiparametric magnetic resonance imaging (MP-MRI) of the prostate with results from MRI guided transrectal ultrasound (MRI/TRUS) fusion prostate biopsy in men with suspected prostate cancer. Thirty-nine consecutive patients who had 3.0T MP-MRI and subsequent MRI/TRUS fusion prostate biopsy were included and 73 MRI-identified targets were sampled by 177 cores. The pre-biopsy MP-MRI consisted of T2-weighted, diffusion weighted (DWI), and dynamic contrast enhanced (DCE) images. The association of quantitative MRI measurements with biopsy histopathology findings was assessed by Mann-Whitney U- test and Kruskal-Wallis test. Of 73 targets, biopsy showed benign prostate tissue in 46 (63%), cancer in 23 (31.5%), and atypia/high grade prostatic intraepithelial neoplasia in four (5.5%) targets. The median volume of cancer-positive targets was 1.3 cm3. The cancer-positive targets were located in the peripheral zone (56.5%), transition zone (39.1%), and seminal vesicle (4.3%). Nine of 23 (39.1%) cancer-positive targets were higher grade cancer (Gleason grade > 6). Higher grade targets and cancer-positive targets compared to benign lesions exhibited lower mean apparent diffusion coefficient (ADC) value (952.7 < 1167.9 < 1278.9), and lower minimal extracellular volume fraction (ECF) (0.13 < 0.185 < 0.213), respectively. The difference in parameters was more pronounced between higher grade cancer and benign lesions. Our findings from a pilot study indicate that quantitative MRI parameters can predict malignant histology on MRI/TRUS fusion prostate biopsy, which is a valuable technique to ensure adequate sampling of MRI-visible suspicious lesions under TRUS guidance and may impact patient management. The DWI-based quantitative measurement exhibits a stronger association with biopsy findings than the other MRI parameters.

  9. Serum total prostate-specific antigen values in men with symptomatic prostate enlargement in Nigeria: role in clinical decision-making.

    PubMed

    Nnabugwu, Ikenna I; Ugwumba, Fred O; Enivwenae, Oghenekaro A; Udeh, Emeka I; Otene, Chris O; Nnabugwu, Chinwe A

    2015-01-01

    Prostatic enlargement is a common cause of bladder outlet obstruction in men in Nigeria. Malignant enlargements must be differentiated from benign enlargements for adequate treatment of each patient. High serum total prostate-specific antigen (tPSA) levels suggest malignancy, but some of the biopsies done due to a serum tPSA value >4 ng/mL would be negative for malignancy because of the low specificity of tPSA for prostate cancer. This study aims to compare the histologic findings of all prostate specimens obtained from core needle biopsy, open simple prostatectomy, and transurethral resection of the prostate with the respective serum tPSA values in an attempt to decipher the role of serum tPSA in the management of these patients. The case notes of patients attended to from April 2009 to March 2012 were analyzed. Essentially, the age of the patient, findings on digital rectal examination, abdominopelvic ultrasonography report on the prostate, serum tPSA, and histology reports from biopsy or prostatectomy specimens as indicated were extracted for analysis. The relationship between age, findings on digital rectal examination, serum tPSA, abdominopelvic ultrasonography report, and histology are compared. A statistically significant relationship existed between a malignant histology and age 65 years and older, suspicious findings on digital rectal examination, suspicious ultrasonography findings, and serum tPSA >10 ng/mL, but not tPSA >4 ng/mL. In Nigerian patients with symptomatic prostate enlargement, serum tPSA should be seen as a continuum with increasing risk of prostate malignancy.

  10. A deep learning approach for real time prostate segmentation in freehand ultrasound guided biopsy.

    PubMed

    Anas, Emran Mohammad Abu; Mousavi, Parvin; Abolmaesumi, Purang

    2018-06-01

    Targeted prostate biopsy, incorporating multi-parametric magnetic resonance imaging (mp-MRI) and its registration with ultrasound, is currently the state-of-the-art in prostate cancer diagnosis. The registration process in most targeted biopsy systems today relies heavily on accurate segmentation of ultrasound images. Automatic or semi-automatic segmentation is typically performed offline prior to the start of the biopsy procedure. In this paper, we present a deep neural network based real-time prostate segmentation technique during the biopsy procedure, hence paving the way for dynamic registration of mp-MRI and ultrasound data. In addition to using convolutional networks for extracting spatial features, the proposed approach employs recurrent networks to exploit the temporal information among a series of ultrasound images. One of the key contributions in the architecture is to use residual convolution in the recurrent networks to improve optimization. We also exploit recurrent connections within and across different layers of the deep networks to maximize the utilization of the temporal information. Furthermore, we perform dense and sparse sampling of the input ultrasound sequence to make the network robust to ultrasound artifacts. Our architecture is trained on 2,238 labeled transrectal ultrasound images, with an additional 637 and 1,017 unseen images used for validation and testing, respectively. We obtain a mean Dice similarity coefficient of 93%, a mean surface distance error of 1.10 mm and a mean Hausdorff distance error of 3.0 mm. A comparison of the reported results with those of a state-of-the-art technique indicates statistically significant improvement achieved by the proposed approach. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Predicting prostate biopsy outcome: prostate health index (phi) and prostate cancer antigen 3 (PCA3) are useful biomarkers.

    PubMed

    Ferro, Matteo; Bruzzese, Dario; Perdonà, Sisto; Mazzarella, Claudia; Marino, Ada; Sorrentino, Alessandra; Di Carlo, Angelina; Autorino, Riccardo; Di Lorenzo, Giuseppe; Buonerba, Carlo; Altieri, Vincenzo; Mariano, Angela; Macchia, Vincenzo; Terracciano, Daniela

    2012-08-16

    Indication for prostate biopsy is presently mainly based on prostate-specific antigen (PSA) serum levels and digital-rectal examination (DRE). In view of the unsatisfactory accuracy of these two diagnostic exams, research has focused on novel markers to improve pre-biopsy prostate cancer detection, such as phi and PCA3. The purpose of this prospective study was to assess the diagnostic accuracy of phi and PCA3 for prostate cancer using biopsy as gold standard. Phi index (Beckman coulter immunoassay), PCA3 score (Progensa PCA3 assay) and other established biomarkers (tPSA, fPSA and %fPSA) were assessed before a 18-core prostate biopsy in a group of 251 subjects at their first biopsy. Values of %p2PSA and phi were significantly higher in patients with PCa compared with PCa-negative group (p<0.001) and also compared with high grade prostatic intraepithelial neoplasia (HGPIN) (p<0.001). PCA3 score values were significantly higher in PCa compared with PCa-negative subjects (p<0.001) and in HGPIN vs PCa-negative patients (p<0.001). ROC curve analysis showed that %p2PSA, phi and PCA3 are predictive of malignancy. In conclusion, %p2PSA, phi and PCA3 may predict a diagnosis of PCa in men undergoing their first prostate biopsy. PCA3 score is more useful in discriminating between HGPIN and non-cancer. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. A Contemporary Prostate Biopsy Risk Calculator Based on Multiple Heterogeneous Cohorts.

    PubMed

    Ankerst, Donna P; Straubinger, Johanna; Selig, Katharina; Guerrios, Lourdes; De Hoedt, Amanda; Hernandez, Javier; Liss, Michael A; Leach, Robin J; Freedland, Stephen J; Kattan, Michael W; Nam, Robert; Haese, Alexander; Montorsi, Francesco; Boorjian, Stephen A; Cooperberg, Matthew R; Poyet, Cedric; Vertosick, Emily; Vickers, Andrew J

    2018-05-16

    Prostate cancer prediction tools provide quantitative guidance for doctor-patient decision-making regarding biopsy. The widely used online Prostate Cancer Prevention Trial Risk Calculator (PCPTRC) utilized data from the 1990s based on six-core biopsies and outdated grading systems. We prospectively gathered data from men undergoing prostate biopsy in multiple diverse North American and European institutions participating in the Prostate Biopsy Collaborative Group (PBCG) in order to build a state-of-the-art risk prediction tool. We obtained data from 15 611 men undergoing 16 369 prostate biopsies during 2006-2017 at eight North American institutions for model-building and three European institutions for validation. We used multinomial logistic regression to estimate the risks of high-grade prostate cancer (Gleason score ≥7) on biopsy based on clinical characteristics, including age, prostate-specific antigen, digital rectal exam, African ancestry, first-degree family history, and prior negative biopsy. We compared the PBCG model to the PCPTRC using internal cross-validation and external validation on the European cohorts. Cross-validation on the North American cohorts (5992 biopsies) yielded the PBCG model area under the receiver operating characteristic curve (AUC) as 75.5% (95% confidence interval: 74.2-76.8), a small improvement over the AUC of 72.3% (70.9-73.7) for the PCPTRC (p<0.0001). However, calibration and clinical net benefit were far superior for the PBCG model. Using a risk threshold of 10%, clinical use of the PBCG model would lead to the equivalent of 25 fewer biopsies per 1000 patients without missing any high-grade cancers. Results were similar on external validation on 10 377 European biopsies. The PBCG model should be used in place of the PCPTRC for prediction of prostate biopsy outcome. A contemporary risk tool for outcomes on prostate biopsy based on the routine clinical risk factors is now available for informed decision-making. Copyright

  13. Solitary fibrous tumor of the prostate: case report and review of the literature.

    PubMed

    Moureau-Zabotto, Laurence; Chetaille, Bruno; Bladou, Franck; Dauvergne, Pierre-Yves; Marcy, Myriam; Perrot, Delphine; Guiramand, Jérôme; Sarran, Anthony; Bertucci, François

    2012-01-01

    Solitary fibrous tumor (SFT), usually described in the pleura, is exceedingly rare in the prostate. We report a 60-year-old man with prostatic SFT revealed by obstructive urinary symptoms, and detected by ultrasonography. Computed tomography (CT) and magnetic resonance imaging suggested a prostatic origin. CT-guided tumor biopsy diagnosed a SFT. A cystoprostatectomy was performed. Pathologic examination showed a 15-cm tumor arising from the prostate and showing histological criteria suggestive of aggressiveness. The surgical resection margins were tumor-free. The patient was then regularly monitored and is still alive in complete remission, 28 months after surgery. In conclusion, we report a new exceptional case of prostatic SFT. We review the literature and discuss the challenging issues of misdiagnosis, prognosis and treatment.

  14. Solitary Fibrous Tumor of the Prostate: Case Report and Review of the Literature

    PubMed Central

    Moureau-Zabotto, Laurence; Chetaille, Bruno; Bladou, Franck; Dauvergne, Pierre-Yves; Marcy, Myriam; Perrot, Delphine; Guiramand, Jérôme; Sarran, Anthony; Bertucci, François

    2012-01-01

    Solitary fibrous tumor (SFT), usually described in the pleura, is exceedingly rare in the prostate. We report a 60-year-old man with prostatic SFT revealed by obstructive urinary symptoms, and detected by ultrasonography. Computed tomography (CT) and magnetic resonance imaging suggested a prostatic origin. CT-guided tumor biopsy diagnosed a SFT. A cystoprostatectomy was performed. Pathologic examination showed a 15-cm tumor arising from the prostate and showing histological criteria suggestive of aggressiveness. The surgical resection margins were tumor-free. The patient was then regularly monitored and is still alive in complete remission, 28 months after surgery. In conclusion, we report a new exceptional case of prostatic SFT. We review the literature and discuss the challenging issues of misdiagnosis, prognosis and treatment. PMID:22379473

  15. Diagnostic Performance of Multiparametric Magnetic Resonance Imaging and Fusion Targeted Biopsy to Detect Significant Prostate Cancer.

    PubMed

    Hoffmann, Manuela A; Taymoorian, Kasra; Ruf, Christian; Gerhards, Arnd; Leyendecker, Karlheinz; Stein, Thomas; Jakobs, Frank M; Schreckenberger, Mathias

    2017-12-01

    Multiparametric magnetic resonance imaging combined with ultrasound-fusion-targeted biopsy of the prostate intends to increase diagnostic precision, which has to be clarified. We performed multiparametric magnetic resonance imaging followed by ultrasound-fusion-guided perineal biopsy in 99 male patients with elevated prostate-specific-antigen and previous negative standard biopsy-procedures. In 33/99 patients (33%) no malignancy could be confirmed by histopathology. Low-grade carcinomas (Gleason-Score 6+7a) were found in 42/66 (64%) and high-grade carcinomas (Gleason-Score ≥7b) in 24/66 (36%) men. A high-grade carcinoma corresponded to PI-RADS 4 or 5 (suspected malignancy) in 21/24 cases, which accounted for a sensitivity of 88% and negative-predictive-value of 85% (p=0.002). Differentiation between high-/low-grade carcinomas (Gleason-Score ≤7a vs. ≥7b) by means of PI-RADS related to a sensitivity of 88% and a negative-predictive-value of 70% (p=0.74). The results support the view that multiparametric magnetic resonance imaging/ultrasound-fusion-guided biopsy promotes considerably higher detection rates of clinically relevant prostate malignancies than do conventional diagnostic procedures. With regard to differentiation between high- and low-grade carcinomas, no significant difference was demonstrated. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  16. No Effect of Music on Anxiety and Pain During Transrectal Prostate Biopsies: A Randomized Trial.

    PubMed

    Packiam, Vignesh T; Nottingham, Charles U; Cohen, Andrew J; Eggener, Scott E; Gerber, Glenn S

    2018-07-01

    To investigate the effect of ambient music on anxiety and pain in men undergoing prostate biopsies. Between September 2015 and June 2016, men undergoing office transrectal prostate biopsy at our institution were randomly assigned to music (n = 85) or control (n = 97) groups. We examined clinical characteristics, pathologic variables, and baseline anxiety using the Trait Instrument of State-Trait Anxiety Inventory. Primary outcomes included anxiety assessed by State Instrument of STAI (STAI-S) and pain using a visual analog scale. There were no significant differences in baseline characteristics between the music and control groups, including median age, prostate-specific antigen, use of magnetic resonance imaging-guided biopsies, or Trait Instrument of State-Trait Anxiety Inventory. The majority (93%) of patients indicated they desired music in their prebiopsy survey. There were no significant differences in STAI-S (33.7 ± 8.9 vs 34.4 ± 9.9, P = .6), pain score (2.3 ± 2.1 vs 2.0 ± 2.1, P = .3), or vital signs between the music and control groups, respectively. There were also no differences in STAI-S, visual analog scale, or vital signs between groups when stratified by age, prostate-specific antigen, or number of previous biopsies. Men who received music were more likely to request music for future prostate biopsy, compared to men who did not (93% vs 83%, P = .07, respectively). This randomized study showed no difference in anxiety or pain scores for patients who had ambient music during transrectal prostate biopsy. Future studies are needed to discern the influence of details including method of music delivery, music type, and utilization of adjunct relaxation tools. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Using the epigenetic field defect to detect prostate cancer in biopsy negative patients.

    PubMed

    Truong, Matthew; Yang, Bing; Livermore, Andrew; Wagner, Jennifer; Weeratunga, Puspha; Huang, Wei; Dhir, Rajiv; Nelson, Joel; Lin, Daniel W; Jarrard, David F

    2013-06-01

    We determined whether a novel combination of field defect DNA methylation markers could predict the presence of prostate cancer using histologically normal transrectal ultrasound guided biopsy cores. Methylation was assessed using quantitative Pyrosequencing® in a training set consisting of 65 nontumor and tumor associated prostate tissues from University of Wisconsin. A multiplex model was generated using multivariate logistic regression and externally validated in blinded fashion in a set of 47 nontumor and tumor associated biopsy specimens from University of Washington. We observed robust methylation differences in all genes at all CpGs assayed (p <0.0001). Regression models incorporating individual genes (EVX1, CAV1 and FGF1) and a gene combination (EVX1 and FGF1) discriminated nontumor from tumor associated tissues in the original training set (AUC 0.796-0.898, p <0.001). On external validation uniplex models incorporating EVX1, CAV1 or FGF1 discriminated tumor from nontumor associated biopsy negative specimens (AUC 0.702, 0.696 and 0.658, respectively, p <0.05). A multiplex model (EVX1 and FGF1) identified patients with prostate cancer (AUC 0.774, p = 0.001) and had a negative predictive value of 0.909. Comparison between 2 separate cores in patients in this validation set revealed similar methylation defects, indicating detection of a widespread field defect. A widespread epigenetic field defect can be used to detect prostate cancer in patients with histologically negative biopsies. To our knowledge this assay is unique, in that it detects alterations in nontumor cells. With further validation this marker combination (EVX1 and FGF1) has the potential to decrease the need for repeat prostate biopsies, a procedure associated with cost and complications. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Elevated Prostate Health Index (phi) and Biopsy Reclassification During Active Surveillance of Prostate Cancer.

    PubMed

    Andreas, Darian; Tosoian, Jeffrey J; Landis, Patricia; Wolf, Sacha; Glavaris, Stephanie; Lotan, Tamara L; Schaeffer, Edward M; Sokoll, Lori J; Ross, Ashley E

    2016-07-01

    The Prostate Health Index (phi) has been FDA approved for decision-making regarding prostate biopsy. Phi has additionally been shown to positively correlate with tumor volume, extraprostatic disease and higher Gleason grade tumors. Here we describe a case in which an elevated phi encouraged biopsy of a gentleman undergoing active surveillance leading to reclassification of his disease as high risk prostate cancer.

  19. Relationship Between Prebiopsy Multiparametric Magnetic Resonance Imaging (MRI), Biopsy Indication, and MRI-ultrasound Fusion-targeted Prostate Biopsy Outcomes.

    PubMed

    Meng, Xiaosong; Rosenkrantz, Andrew B; Mendhiratta, Neil; Fenstermaker, Michael; Huang, Richard; Wysock, James S; Bjurlin, Marc A; Marshall, Susan; Deng, Fang-Ming; Zhou, Ming; Melamed, Jonathan; Huang, William C; Lepor, Herbert; Taneja, Samir S

    2016-03-01

    Increasing evidence supports the use of magnetic resonance imaging (MRI)-ultrasound fusion-targeted prostate biopsy (MRF-TB) to improve the detection of clinically significant prostate cancer (PCa) while limiting detection of indolent disease compared to systematic 12-core biopsy (SB). To compare MRF-TB and SB results and investigate the relationship between biopsy outcomes and prebiopsy MRI. Retrospective analysis of a prospectively acquired cohort of men presenting for prostate biopsy over a 26-mo period. A total of 601 of 803 consecutively eligible men were included. All men were offered prebiopsy MRI and assigned a maximum MRI suspicion score (mSS). Men with an MRI abnormality underwent combined MRF-TB and SB. Detection rates for all PCa and high-grade PCa (Gleason score [GS] ≥7) were compared using the McNemar test. MRF-TB detected fewer GS 6 PCas (75 vs 121; p<0.001) and more GS ≥7 PCas (158 vs 117; p<0.001) than SB. Higher mSS was associated with higher detection of GS ≥7 PCa (p<0.001) but was not correlated with detection of GS 6 PCa. Prediction of GS ≥7 disease by mSS varied according to biopsy history. Compared to SB, MRF-TB identified more GS ≥7 PCas in men with no prior biopsy (88 vs 72; p=0.012), in men with a prior negative biopsy (28 vs 16; p=0.010), and in men with a prior cancer diagnosis (42 vs 29; p=0.043). MRF-TB detected fewer GS 6 PCas in men with no prior biopsy (32 vs 60; p<0.001) and men with prior cancer (30 vs 46; p=0.034). Limitations include the retrospective design and the potential for selection bias given a referral population. MRF-TB detects more high-grade PCas than SB while limiting detection of GS 6 PCa in men presenting for prostate biopsy. These findings suggest that prebiopsy multiparametric MRI and MRF-TB should be considered for all men undergoing prostate biopsy. In addition, mSS in conjunction with biopsy indications may ultimately help in identifying men at low risk of high-grade cancer for whom prostate biopsy

  20. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    PubMed

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores <12, and lack of biopsy location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  1. Intraductal Carcinoma of the Prostate on Diagnostic Needle Biopsy Predicts Prostate Cancer Mortality: A Population-Based Study.

    PubMed

    Saeter, Thorstein; Vlatkovic, Ljiljana; Waaler, Gudmund; Servoll, Einar; Nesland, Jahn M; Axcrona, Karol; Axcrona, Ulrika

    2017-06-01

    Intraductal carcinoma of the prostate (IDC-P) is a distinct histopathologic feature associated with high-grade, advanced prostate cancer. Although studies have shown that IDC-P is a predictor of progression following surgical or radiation treatment for prostate cancer, there are sparse data regarding IDC-P on diagnostic needle biopsy as a prognosticator of prostate cancer mortality. This was a population-based study of all prostate cancer patients diagnosed using needle biopsy and without evidence of systemic disease between 1991 and 1999 within a defined geographic region of Norway. Patients were identified by cross-referencing the Norwegian Cancer Registry. Of 318 eligible patients, 283 had biopsy specimens available for central pathology review. Clinical data were obtained from medical charts. We examined whether IDC-P on diagnostic needle biopsy was associated with adverse clinicopathological features and prostate cancer mortality. Patients with IDC-P on diagnostic needle biopsy had a more advanced stage and a higher Gleason score compared to patients without IDC-P. IDC-P was also associated with an intensively reactive stroma. The 10-year prostate cancer-specific survival was 69% for patients with IDC-P on diagnostic needle biopsy and 89% for patients without IDC-P (Log rank P-value < 0.005). The presence of IDC-P on diagnostic needle biopsy remained an independent predictor of prostate cancer mortality after adjustments for clinical prognostic factors and treatment. After adjustment for the newly implemented Grade Group system of prostate cancer, IDC-P showed a strong tendency toward statistical significance. However, IDC-P did not remain a statistically significant predictor in the multivariable analysis. IDC-P on diagnostic needle biopsy is an indicator of prostate cancer with a high risk of mortality. Accordingly, a diagnosis of IDC-P on needle biopsy should be reported and considered a feature of high-risk prostate cancer. Moreover, the association

  2. The 'green whistle': a novel method of analgesia for transrectal prostate biopsy.

    PubMed

    Grummet, Jeremy; Huang, Sean; Konstantatos, Alex; Frydenberg, Mark

    2012-12-01

    • Patients undergoing TRUS-guided biopsies were each given a Penthrox inhaler to self-administer during the procedure and instructed in its use. • Immediately after the procedure, patients were asked to rate their pain using a verbal rating scale from 0 to 10. • In all, 42 consecutive men underwent a TRUS-guided biopsy. • The median pain score was 3. • All 42 patients stated they would be happy to undergo the same procedure again. The only adverse effects reported by patients were brief light-headedness and a sickly sweet taste. • This study of our initial experience using Penthrox suggests that it may have a role in analgesia for TRUS-guided biopsy. • It may provide safe, adequate analgesia that is easy for urologists to use and avoids excessive use of resources. • Planning for a randomised control trial comparing Penthrox to the current 'gold standard' of prostatic infiltration of local anaesthetic is presently underway. © 2012 THE AUTHORS. BJU INTERNATIONAL © 2012 BJU INTERNATIONAL.

  3. Inflammation on Prostate Needle Biopsy is Associated with Lower Prostate Cancer Risk: A Meta-Analysis.

    PubMed

    Vasavada, Shaleen R; Dobbs, Ryan W; Kajdacsy-Balla, André A; Abern, Michael R; Moreira, Daniel M

    2018-05-01

    We performed a comprehensive literature review and meta-analysis to evaluate the association of inflammation on prostate needle biopsies and prostate cancer risk. We searched Embase®, PubMed® and Web of Science™ from January 1, 1990 to October 1, 2016 for abstracts containing the key words prostate cancer, inflammation and biopsy. Study inclusion criteria were original research, adult human subjects, cohort or case-control study design, histological inflammation on prostate needle biopsy and prostate cancer on histology. Two independent teams reviewed abstracts and extracted data from the selected manuscripts. Combined ORs and 95% CIs of any, acute and chronic inflammation were calculated using the random effects method. Of the 1,030 retrieved abstracts 46 underwent full text review and 25 were included in the final analysis, comprising a total of 20,585 subjects and 6,641 patients with prostate cancer. There was significant heterogeneity among studies (I 2 = 84.4%, p <0.001). The presence of any inflammation was significantly associated with a lower prostate cancer risk in 25 studies (OR 0.455, 95% CI 0.337-0.573). There was no evidence of publication bias (p >0.05). When subanalyzed by inflammation type, acute inflammation in 4 studies and chronic inflammation in 15 were each associated with a lower prostate cancer risk (OR 0.681, 95% CI 0.450-0.913 and OR 0.499, 95% CI 0.334-0.665, respectively). In a meta-analysis of 25 studies inflammation on prostate needle biopsy was associated with a lower prostate cancer risk. Clinically the presence of inflammation on prostate needle biopsy may lower the risk of a subsequent prostate cancer diagnosis. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Prostate cancer gene 3 and multiparametric magnetic resonance can reduce unnecessary biopsies: decision curve analysis to evaluate predictive models.

    PubMed

    Busetto, Gian Maria; De Berardinis, Ettore; Sciarra, Alessandro; Panebianco, Valeria; Giovannone, Riccardo; Rosato, Stefano; D'Errigo, Paola; Di Silverio, Franco; Gentile, Vincenzo; Salciccia, Stefano

    2013-12-01

    To overcome the well-known prostate-specific antigen limits, several new biomarkers have been proposed. Since its introduction in clinical practice, the urinary prostate cancer gene 3 (PCA3) assay has shown promising results for prostate cancer (PC) detection. Furthermore, multiparametric magnetic resonance imaging (mMRI) has the ability to better describe several aspects of PC. A prospective study of 171 patients with negative prostate biopsy findings and a persistent high prostate-specific antigen level was conducted to assess the role of mMRI and PCA3 in identifying PC. All patients underwent the PCA3 test and mMRI before a second transrectal ultrasound-guided prostate biopsy. The accuracy and reliability of PCA3 (3 different cutoff points) and mMRI were evaluated. Four multivariate logistic regression models were analyzed, in terms of discrimination and the cost benefit, to assess the clinical role of PCA3 and mMRI in predicting the biopsy outcome. A decision curve analysis was also plotted. Repeated transrectal ultrasound-guided biopsy identified 68 new cases (41.7%) of PC. The sensitivity and specificity of the PCA3 test and mMRI was 68% and 49% and 74% and 90%, respectively. Evaluating the regression models, the best discrimination (area under the curve 0.808) was obtained using the full model (base clinical model plus mMRI and PCA3). The decision curve analysis, to evaluate the cost/benefit ratio, showed good performance in predicting PC with the model that included mMRI and PCA3. mMRI increased the accuracy and sensitivity of the PCA3 test, and the use of the full model significantly improved the cost/benefit ratio, avoiding unnecessary biopsies. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Prostate contouring in MRI guided biopsy.

    PubMed

    Vikal, Siddharth; Haker, Steven; Tempany, Clare; Fichtinger, Gabor

    2009-03-27

    With MRI possibly becoming a modality of choice for detection and staging of prostate cancer, fast and accurate outlining of the prostate is required in the volume of clinical interest. We present a semi-automatic algorithm that uses a priori knowledge of prostate shape to arrive at the final prostate contour. The contour of one slice is then used as initial estimate in the neighboring slices. Thus we propagate the contour in 3D through steps of refinement in each slice. The algorithm makes only minimum assumptions about the prostate shape. A statistical shape model of prostate contour in polar transform space is employed to narrow search space. Further, shape guidance is implicitly imposed by allowing only plausible edge orientations using template matching. The algorithm does not require region-homogeneity, discriminative edge force, or any particular edge profile. Likewise, it makes no assumption on the imaging coils and pulse sequences used and it is robust to the patient's pose (supine, prone, etc.). The contour method was validated using expert segmentation on clinical MRI data. We recorded a mean absolute distance of 2.0 ± 0.6 mm and dice similarity coefficient of 0.93 ± 0.3 in midsection. The algorithm takes about 1 second per slice.

  6. Prostate contouring in MRI guided biopsy

    PubMed Central

    Vikal, Siddharth; Haker, Steven; Tempany, Clare; Fichtinger, Gabor

    2010-01-01

    With MRI possibly becoming a modality of choice for detection and staging of prostate cancer, fast and accurate outlining of the prostate is required in the volume of clinical interest. We present a semi-automatic algorithm that uses a priori knowledge of prostate shape to arrive at the final prostate contour. The contour of one slice is then used as initial estimate in the neighboring slices. Thus we propagate the contour in 3D through steps of refinement in each slice. The algorithm makes only minimum assumptions about the prostate shape. A statistical shape model of prostate contour in polar transform space is employed to narrow search space. Further, shape guidance is implicitly imposed by allowing only plausible edge orientations using template matching. The algorithm does not require region-homogeneity, discriminative edge force, or any particular edge profile. Likewise, it makes no assumption on the imaging coils and pulse sequences used and it is robust to the patient's pose (supine, prone, etc.). The contour method was validated using expert segmentation on clinical MRI data. We recorded a mean absolute distance of 2.0 ± 0.6 mm and dice similarity coefficient of 0.93 ± 0.3 in midsection. The algorithm takes about 1 second per slice. PMID:21132083

  7. [The local anesthesia for the prostatic biopsies echo-guided: forward-looking randomized study comparing two methods].

    PubMed

    Moudouni, S M; Zahraoui, M R; Adarmouch, L; Lakmichi, M A; Bentani, N; Jarir, R; Dahami, Z; Amine, M; Sarf, I

    2014-02-01

    The realization of the prostatic biopsies is a painful act. The objective of our work was to compare the analgesic efficiency of the injection of the lidocaine at the level of periprostatics laterals and apical areas compared with the use of gel of lidocaine intrarectal associated with the taking of oral tramadol. Between November 2007 and December 2009, 60 patients admitted in the service of urology of the university hospital Mohammed VI of Marrakesh for prostatic biopsies were randomized in two groups. The group 1 (30 patients) received two tablets from tramadol 50mg with 10 mL of gel of lidocaine 2% intrarectal while 30 patients of the group 2 received 10 mL from lidocaine 2% injected at the level of periprostatics laterals and apicales. The pain was estimated by a visual analog scale (AVS) at the introduction of the probe of echography (AVS 1), at the time of the biopsy (AVS 2) and 20 minutes later (AVS 3). There was no significant difference between both groups concerning AVS 1 means. The average score of the pain was significantly lower in the group 2 for the AVS 2 and AVS 3. The periprostatics anesthesia assured a better control of the pain at the time of the prostatic biopsy and 20 minutes later, without increase of the complications. We recommend it to decrease the pain and the discomfort related to this technique. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  8. Why and Where do We Miss Significant Prostate Cancer with Multi-parametric Magnetic Resonance Imaging followed by Magnetic Resonance-guided and Transrectal Ultrasound-guided Biopsy in Biopsy-naïve Men?

    PubMed

    Schouten, Martijn G; van der Leest, Marloes; Pokorny, Morgan; Hoogenboom, Martijn; Barentsz, Jelle O; Thompson, Les C; Fütterer, Jurgen J

    2017-06-01

    Knowledge of significant prostate (sPCa) locations being missed with magnetic resonance (MR)- and transrectal ultrasound (TRUS)-guided biopsy (Bx) may help to improve these techniques. To identify the location of sPCa lesions being missed with MR- and TRUS-Bx. In a referral center, 223 consecutive Bx-naive men with elevated prostate specific antigen level and/or abnormal digital rectal examination were included. Histopathologically-proven cancer locations, Gleason score, and tumor length were determined. All patients underwent multi-parametric MRI and 12-core systematic TRUS-Bx. MR-Bx was performed in all patients with suspicion of PCa on multi-parametric MRI (n=142). Cancer locations were compared between MR- and TRUS-Bx. Proportions were expressed as percentages, and the corresponding 95% confidence intervals were calculated. In total, 191 lesions were found in 108 patients with sPCa. From these lesion 74% (141/191) were defined as sPCa on either MR- or TRUS-Bx. MR-Bx detected 74% (105/141) of these lesions and 61% (86/141) with TRUS-Bx. TRUS-Bx detected more lesions compared with MR-Bx (140 vs 109). However, these lesions were often low risk (39%). Significant lesions missed with MR-Bx most often had involvement of dorsolateral (58%) and apical (37%) segments and missed segments with TRUS-Bx were located anteriorly (79%), anterior midprostate (50%), and anterior apex (23%). Both techniques have difficulties in detecting apical lesions. MR-Bx most often missed cancer with involvement of the dorsolateral part (58%) and TRUS-Bx with involvement of the anterior part (79%). Both biopsy techniques miss cancer in specific locations within the prostate. Identification of these lesions may help to improve these techniques. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  9. Sedoanalgesia With Midazolam and Fentanyl Citrate Controls Probe Pain During Prostate Biopsy by Transrectal Ultrasound

    PubMed Central

    Tsuji, Fábio Hissachi; Chambó, Renato Caretta; Agostinho, Aparecido Donizeti; Trindade Filho, José Carlos Souza

    2014-01-01

    Purpose To assess the pain intensity of patients administered midazolam and fentanyl citrate before undergoing transrectal ultrasound-guided prostate biopsy. Materials and Methods This was a study in patients with different indications for prostate biopsy in whom 5 mg of midazolam and 50 µg of fentanyl citrate was administered intravenously 3 minutes before the procedure. After biopsy, pain was assessed by use of a visual analogue scale (VAS) in three stages: VAS 1, during probe introduction; VAS 2, during needle penetration into prostate tissue; and VAS 3, in the weeks following the exam. Pain intensity at these different times was tested with stratification by age, race, education, prostate volume, rebiopsy, and anxiety before biopsy. Pain was ranked according to the following scores: 0 (no pain), 1-3 (mild pain), 4-7 (moderate pain), and 8-10 (severe pain). Statistical analysis was performed by using Kruskal-Wallis and Wilcoxon two-tailed tests with a significance of 5%. Results Pain intensity was not influenced by any risk factors. The mean VAS 1 score was 1.95±1.98, the mean VAS 2 score was 2.73±2.55, and the mean VAS 3 score was 0.3±0.9, showing greater pain at the time of needle penetration than in other situations (VAS 2>VAS 1>VAS 3, p=0.0013, p=0.0001, respectively). Seventy-five percent of patients reported a VAS pain scale of less than 3.1 or mild pain. Conclusions Intravenous sedation and analgesia with midazolam and fentanyl citrate is a good method for reducing pain caused by prostate biopsy, even during probe insertion. PMID:24578806

  10. Modified perianal/pericapsular anesthesia for transrectal biopsy of prostate in patients with anal rectal problems.

    PubMed

    Kravchick, Sergey; Yoffe, Boris; Cytron, Shmuel

    2007-01-01

    To modify our technique of perianal anesthesia and use it in patients with painful conditions of the rectum and/or anus. A total of 31 consecutive patients with anal-rectal problems underwent prostate needle biopsy. Of these, 17 were referred to our hospital after vain attempts to insert a transrectal ultrasound probe. Patients received a perianal-pericapsular injection of 1% lidocaine. Pain perception was separately assessed for probe insertion and biopsies using a visual pain analog score. Only in 1 patient were we unable to insert the transrectal ultrasound probe. The mean patient age was 65.28 +/- 5.35 years. We performed a mean of 12.25 biopsies per case. At probe insertion, the mean pain score was 2.2 +/- 0.83. During the biopsy punctures, the mean pain level was 2.53 +/- 1.054. We did not find any increase in the complication rate related to the anesthesia method. Modified perianal anesthesia can be used for transrectal ultrasound-guided biopsy of the prostate in patients with anal-rectal problems, because it provides significant pain relief.

  11. Development of an MRI-Guided Intra-Prostatic Needle Placement System

    DTIC Science & Technology

    2011-07-01

    and intra-operative imaging using techniques such as those described by Haker , et al. [18]. Target points for the needle insertion are selected... Haker , S., Fichtinger, G., Tem- pany, C.: Transperineal prostate biopsy under magnetic resonance image guid- ance: A needle placement accuracy study 26...clinically localized prostate cancer. Int J Radiat Oncol Biol Phys 42(3), 507–515 (1998) 9. DiMaio, S.P., Pieper, S., Chinzei, K., Hata, N., Haker , S.J

  12. Trans-rectal interventional MRI: initial prostate biopsy experience

    NASA Astrophysics Data System (ADS)

    Greenwood, Bernadette M.; Behluli, Meliha R.; Feller, John F.; May, Stuart T.; Princenthal, Robert; Winkel, Alex; Kaminsky, David B.

    2010-02-01

    Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate gland when evaluated along with T2-weighted images, diffusion-weighted images (DWI) and their corresponding apparent diffusion coefficient (ADC) maps can yield valuable information in patients with rising or elevated serum prostate-specific antigen (PSA) levels1. In some cases, patients present with multiple negative trans-rectal ultrasound (TRUS) biopsies, often placing the patient into a cycle of active surveillance. Recently, more patients are undergoing TRIM for targeted biopsy of suspicious findings with a cancer yield of ~59% compared to 15% for second TRUS biopsy2 to solve this diagnostic dilemma and plan treatment. Patients were imaged in two separate sessions on a 1.5T magnet using a cardiac phased array parallel imaging coil. Automated CAD software was used to identify areas of wash-out. If a suspicious finding was identified on all sequences it was followed by a second imaging session. Under MRI-guidance, cores were acquired from each target region3. In one case the microscopic diagnosis was prostatic intraepithelial neoplasia (PIN), in the other it was invasive adenocarcinoma. Patient 1 had two negative TRUS biopsies and a PSA level of 9ng/mL. Patient 2 had a PSA of 7.2ng/mL. He underwent TRUS biopsy which was negative for malignancy. He was able to go on to treatment for his prostate carcinoma (PCa)4. MRI may have an important role in a subset of patients with multiple negative TRUS biopsies and elevated or rising PSA.

  13. Racial and Ethnic Variation in Time to Prostate Biopsy After an Elevated Screening Level of Serum Prostate-specific Antigen.

    PubMed

    Reading, Stephanie R; Porter, Kimberly R; Hsu, Jin-Wen Y; Wallner, Lauren P; Loo, Ronald K; Jacobsen, Steven J

    2016-10-01

    To examine the racial and ethnic variation in time to prostate biopsy after an elevated screening level of serum prostate-specific antigen (PSA). Male members of the Kaiser Permanente of Southern California health plan, 45 years of age or older, with no history of prostate cancer or a prostate biopsy, and at least 1 elevated screening level of serum PSA between January 1, 1998 and December 31, 2007 were retrospectively identified (n = 59,506). All participants were passively followed via electronic health records until their time of prostate biopsy, death, membership disenrollment, or study conclusion (December 31, 2014), whichever was the initial event. Proportional hazard regression analyses were used to estimate the association between time from an elevated screening level of serum PSA to prostate biopsy, adjusting for age, benign prostatic hyperplasia, prostatitis, type 2 diabetes mellitus, hypertension, and Charlson Comorbidity Index score. Median time until biopsy was 0.6 years (214 days), with approximately 41% of participants receiving a prostate biopsy within the study period. Results from the fully adjusted analysis indicated that the non-Hispanic Asian or Pacific Islanders (hazard ratio: 1.10, 95% confidence interval: [1.04, 1.15]) and the non-Hispanic blacks (hazard ratio: 1.04, 95% confidence interval: [1.00, 1.08]) had a slightly shorter time to prostate biopsy after an elevated screening level of serum PSA compared to the non-Hispanic whites. These data suggest that, within an integrated healthcare organization, minimal differences exist between racial and ethnic subgroups in their time to prostate biopsy after an elevated screening level of serum PSA. Copyright © 2016. Published by Elsevier Inc.

  14. Clinical and microbiological characteristics of spontaneous acute prostatitis and transrectal prostate biopsy-related acute prostatitis: Is transrectal prostate biopsy-related acute prostatitis a distinct acute prostatitis category?

    PubMed

    Kim, Jong Wook; Oh, Mi Mi; Bae, Jae Hyun; Kang, Seok Ho; Park, Hong Seok; Moon, Du Geon

    2015-06-01

    This study aimed to compare the clinical and microbiological characteristics between acute bacterial prostatitis and transrectal biopsy-related acute prostatitis. We retrospectively reviewed the records of 135 patients hospitalized for acute prostatitis in three urological centers between 2004 and 2013. Acute bacterial prostatitis was diagnosed according to typical symptoms, findings of physical examination, and laboratory test results. Clinical variables, laboratory test results, and anti-microbial susceptibility results were reviewed. Patients were classified into the spontaneous acute prostatitis group (S-ABP) or biopsy-related acute prostatitis (Bx-ABP) for comparison of their clinical, laboratory, and microbiological findings. The mean age of all patients was 61.7 ± 12.9 years. Compared with S-ABP patients, Bx-ABP patients were significantly older, had larger prostate volumes, higher PSA values, higher peak fever temperatures, and higher incidence of septicemia and antibiotic-resistant bacteria. Overall, of the 135 patients, 57.8% had positive bacterial urine and/or blood cultures. Bx-ABP patients had a higher incidence of bacterial (urine and/or blood) positive cultures compared to S-ABP patients (66.7% versus 55.6%). Escherichia coli was the predominant organism in both groups, but it was more common in Bx-ABP (88.9%) than in S-ABP (66.7%). Extended spectrum beta-lactamase -producing bacteria accounted for 64.7% of culture-positive patients in the Bx-ABP group compared to 13.3% in the S-ABP group. Bx-ABP patients showed a higher incidence of septicemia and antibiotic-resistant bacteria than S-ABP patients. These results have important implications for the management and antimicrobial treatment of Bx-ABP, which may well deserve to be considered a distinct prostatitis category. Copyright © 2015 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  15. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  16. Thin-needle aspiration biopsy of the prostate.

    PubMed

    Koss, L G; Woyke, S; Schreiber, K; Kohlberg, W; Freed, S Z

    1984-05-01

    The authors summarize the current status of thin-needle aspiration biopsy of the prostate and evaluate the accomplishments and limitations of this method of diagnosis. Historical developments, indications, technique, contraindications, complications, cytology of aspirates, diagnostic efficacy of aspirates, and grading of prostatic carcinomas are discussed.

  17. Usefulness of GATA-3 as a marker of seminal epithelium in prostate biopsies.

    PubMed

    Ortiz-Rey, J A; Chantada-de la Fuente, D; Peteiro-Cancelo, M Á; Gómez-de María, C; San Miguel-Fraile, M P

    2017-11-01

    The incidental presence of seminal vesicle epithelium in prostate needle biopsies is generally recognisable through routine microscopy. However, the biopsy can sometimes be erroneously interpreted as malignant due to its architectural and cytological characteristics, and immunohistochemistry can be useful for correctly identifying the biopsy. Our objective was to analyse the potential usefulness of GATA-3 as a marker of seminal epithelium. Through immunohistochemistry with a monoclonal anti-GATA-3 antibody (clone L50-823), we studied seminal vesicle sections from 20 prostatectomy specimens, 12 prostate needle biopsies that contained seminal vesicle tissue and 68 prostate biopsies without seminal vesicle epithelium, 36 of which showed adenocarcinoma. Staining for GATA-3 was intense in the 20 seminal vesicles of the prostatectomy specimens and in the 12 prostate needle biopsies that contained seminal epithelium. In the 60 biopsies without a seminal vesicle, GATA-3 was positive in the prostate basal cells and even in the secretory cells (57 cases), although with less intensity in 55 of the cases. One of the 36 prostatic adenocarcinomas tested positive for GATA-3. The intense immunohistochemical expression of GATA-3 in the seminal vesicle epithelium can help identify the epithelium in prostate biopsies. This marker is also positive in the basal cells of healthy prostates and, with less intensity, in the secretory cells. Positivity, weak or moderate, is observed on rare occasions in prostatic adenocarcinomas. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Upgrading the Gleason Score in Extended Prostate Biopsy: Implications for Treatment Choice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreira Leite, Katia Ramos; Laboratory of Surgical and Molecular Pathology - Hospital Sirio Libanes, Sao Paulo; Camara-Lopes, Luiz H.A.

    2009-02-01

    Purpose: To determine the incidence of overestimation of Gleason score (GS) in extended prostate biopsy, and consequently circumventing unnecessary aggressive treatment. Methods and Materials: This is a retrospective study of 464 patients who underwent prostate biopsy and radical prostatectomy between January 2001 and November 2007. The GS from biopsy and radical prostatectomy were compared. The incidence of overestimation of GS in biopsies and tumor volume were studied. Multivariate analysis was applied to find parameters that predict upgrading the GS in prostate biopsy. Results: The exact agreement of GS between prostate biopsy and radical prostatectomy occurred in 56.9% of cases. Inmore » 29.1% cases it was underestimated, and it was overestimated in 14%. One hundred and six (22.8%) patients received a diagnosis of high GS (8, 9, or 10) in a prostate biopsy. In 29.2% of cases, the definitive Gleason Score was 7 or lower. In cases in which GS was overestimated in the biopsy, tumors were significantly smaller. In multivariate analysis, the total percentage of tumor was the only independent factor in overestimation of GS. Tumors occupying less than 33% of cores had a 5.6-fold greater chance of being overestimated. Conclusion: In the extended biopsy era and after the International Society of Urological Pathology consensus on GS, almost one third of tumors considered to have high GS at the biopsy may be intermediate-risk cancers. In that condition, tumors are smaller in biopsy. This should be remembered by professionals involved with prostate cancer to avoid overtreatment and undesirable side effects.« less

  19. Body mass index influences prostate cancer risk at biopsy in Japanese men.

    PubMed

    Masuda, Hitoshi; Kagawa, Makoto; Kawakami, Satoru; Numao, Noboru; Matsuoka, Yoh; Yokoyama, Minato; Yamamoto, Shinya; Yonese, Junji; Fukui, Iwao; Kihara, Kazunori

    2013-07-01

    To determine the relationship between body mass index and prostate cancer risk at biopsy in Japanese men, and to compared the risk with that of Caucasian men. We retrospectively evaluated 3966 men with prostate-specific antigen levels from 2.5 to 19.9 ng/mL who underwent an initial extended prostate biopsy. Using logistic regression, odds ratios of each body mass index category for risk of prostate cancer and high-grade disease (Gleason score ≥4 + 3) were estimated after controlling for age, prostate-specific antigen, %free prostate-specific antigen, prostate volume, digital rectal examination findings, family history of prostate cancer and the number of biopsy cores. Patients were divided into six categories according to their body mass index (kg/m(2) ) as follows: <21.0, 21.0-22.9, 23.0-24.9, 25.0-26.9, 27.0-29.9 and ≥30.0. A significant positive association was observed between body mass index and prostate cancer risk at biopsy, with an increased risk observed in men whose body mass index was ≥27.0 compared with the reference group. A significantly increased risk starting at body mass index ≥25.0 was found in high-grade disease. In contrast to our results, there has been no reported increase in the risk of prostate cancer at biopsy in Caucasians within the overweight range (body mass index of 25.0-29.9 based on World Health Organization classification). Japanese men within the overweight body mass index range who have an elevated prostate-specific antigen level also have a significant risk of harboring prostate cancer, especially high-grade disease. Overweight Japanese might be at greater prostate cancer risk at biopsy than overweight Caucasians. © 2012 The Japanese Urological Association.

  20. Twelve-month prostate volume reduction after MRI-guided transurethral ultrasound ablation of the prostate.

    PubMed

    Bonekamp, David; Wolf, M B; Roethke, M C; Pahernik, S; Hadaschik, B A; Hatiboglu, G; Kuru, T H; Popeneciu, I V; Chin, J L; Billia, M; Relle, J; Hafron, J; Nandalur, K R; Staruch, R M; Burtnyk, M; Hohenfellner, M; Schlemmer, H-P

    2018-06-25

    To quantitatively assess 12-month prostate volume (PV) reduction based on T2-weighted MRI and immediate post-treatment contrast-enhanced MRI non-perfused volume (NPV), and to compare measurements with predictions of acute and delayed ablation volumes based on MR-thermometry (MR-t), in a central radiology review of the Phase I clinical trial of MRI-guided transurethral ultrasound ablation (TULSA) in patients with localized prostate cancer. Treatment day MRI and 12-month follow-up MRI and biopsy were available for central radiology review in 29 of 30 patients from the published institutional review board-approved, prospective, multi-centre, single-arm Phase I clinical trial of TULSA. Viable PV at 12 months was measured as the remaining PV on T2-weighted MRI, less 12-month NPV, scaled by the fraction of fibrosis in 12-month biopsy cores. Reduction of viable PV was compared to predictions based on the fraction of the prostate covered by the MR-t derived acute thermal ablation volume (ATAV, 55°C isotherm), delayed thermal ablation volume (DTAV, 240 cumulative equivalent minutes at 43°C thermal dose isocontour) and treatment-day NPV. We also report linear and volumetric comparisons between metrics. After TULSA, the median 12-month reduction in viable PV was 88%. DTAV predicted a reduction of 90%. Treatment day NPV predicted only 53% volume reduction, and underestimated ATAV and DTAV by 36% and 51%. Quantitative volumetry of the TULSA phase I MR and biopsy data identifies DTAV (240 CEM43 thermal dose boundary) as a useful predictor of viable prostate tissue reduction at 12 months. Immediate post-treatment NPV underestimates tissue ablation. • MRI-guided transurethral ultrasound ablation (TULSA) achieved an 88% reduction of viable prostate tissue volume at 12 months, in excellent agreement with expectation from thermal dose calculations. • Non-perfused volume on immediate post-treatment contrast-enhanced MRI represents only 64% of the acute thermal ablation volume

  1. Malakoplakia of the Prostate as a Mimicker of Prostate Cancer on Prostate Health Index and Magnetic Resonance Imaging-Fusion Prostate Biopsy: A Case Report.

    PubMed

    Heah, Nathaniel H; Tan, Teck Wei; Tan, Yung Khan

    2017-01-01

    Background: Isolated malakoplakia of the prostate is a rare inflammatory condition that has been clinically mistaken for prostatic malignancies. The development of Prostate Imaging Reporting and Data System (PI-RADS) classifications, and Prostate Health Index (PHI) has led to more accurate diagnosis of clinically significant disease and stratification of patients that may be at risk of prostate cancer. Case Presentation: We present a case of a 75-year-old male who was on follow-up with our hospital for elevated prostate specific antigen (PSA). He was admitted for an episode of urosepsis, which was treated with antibiotics and subsequently underwent further workup and was found to have a raised PHI, as well as a high PI-RADS classification and was later found to have malakoplakia based on histology of prostate tissue obtained during targeted magnetic resonance imaging (MRI)-guided fusion prostate biopsy. Conclusion: To our understanding, this is the first case where a prostate lesion has been labeled as a PI-RADS 5 lesion, with elevated PHI that has subsequently been proven histologically to be malakoplakia. An important possible confounder is the interval between the MRI and the episode of urosepsis and it is well known that urosepsis can affect the PSA and MRI result. We present this case to highlight the potential for a false diagnosis of prostate cancer, in spite of laboratory and radiological findings.

  2. Risk assessment models to evaluate the necessity of prostate biopsies in North Chinese patients with 4-50 ng/mL PSA.

    PubMed

    Zhao, Jing; Liu, Shuai; Gao, Dexuan; Ding, Sentai; Niu, Zhihong; Zhang, Hui; Huang, Zhilong; Qiu, Juhui; Li, Qing; Li, Ning; Xie, Fang; Cui, Jilei; Lu, Jiaju

    2017-02-07

    Prostate-specific antigen (PSA) is widely used for prostate cancer screening, but low specificity results in high false positive rates of prostate biopsies. To develop new risk assessment models to overcome the diagnostic limitation of PSA and reduce unnecessary prostate biopsies in North Chinese patients with 4-50 ng/mL PSA. A total of 702 patients in seven hospitals with 4-10 and 10-50 ng/mL PSA, respectively, who had undergone transrectal ultrasound-guided prostate biopsies, were assessed. Analysis-modeling stage for several clinical indexes related to prostate cancer and renal function was carried out. Multiple logistic regression analyses were used to develop new risk assessment models of prostate cancer for both PSA level ranges 4-10 and 10-50 ng/mL. External validation stage of the new models was performed to assess the necessity of biopsy. The new models for both PSA ranges performed significantly better than PSA for detecting prostate cancers. Both models showed higher areas under the curves (0.937 and 0.873, respectively) compared with PSA alone (0.624 and 0.595), at pre-determined cut-off values of 0.1067 and 0.6183, respectively. Patients above the cut-off values were recommended for immediate biopsy, while the others were actively observed. External validation of the models showed significantly increased detection rates for prostate cancer (4-10 ng/mL group, 39.29% vs 17.79%, p=0.006; 10-50 ng/mL group, 71.83% vs 50.0%, p=0.015). We developed risk assessment models for North Chinese patients with 4-50 ng/mL PSA to reduce unnecessary prostate biopsies and increase the detection rate of prostate cancer.

  3. Determinants of complications after multiple transrectal core biopsies of the prostate.

    PubMed

    Norberg, M; Holmberg, L; Häggman, M; Magnusson, A

    1996-01-01

    Transrectal ultrasound-guided biopsies of the prostate were performed on 347 consecutive men. All patients were given prophylactic antibiotics. The first 199 patients received 400 mg norfloxacin immediately after the biopsies were performed and 400 mg the same evening. The second group of 148 patients received 400 mg of norfloxacin 1 h before the examination followed by five doses administered twice daily. A total of 15 major complications were noted. In the first group the complication rate was 6.5% and in the second group 1.4%. The different regimes of prophylactic antibiotic treatment were the only parameters shown to have a statistically significant impact on the complication rate. The number of complications decreased, but were not eliminated, when prophylactic treatment with norfloxacin was given before the biopsies were taken and continued for a total of 3 days.

  4. Systematic Assessment Reveals Lack of Understandability for Prostate Biopsy Online Patient Education Materials.

    PubMed

    Maciolek, Kimberly A; Jarrard, David F; Abel, E Jason; Best, Sara L

    2017-11-01

    To evaluate the accuracy, readability, understandability, and actionability of Internet patient education materials (PEM) about transrectal ultrasound-guided prostate biopsy. A comprehensive Internet search was performed to find PEM with pre- or postbiopsy instructions. PEM that were duplicates, government affiliated, international, or video based were excluded. Biopsy instructions were evaluated for accuracy and presence of essential topics. Readability was assessed via word count and Flesch-Kincaid Grade Level. Understandability and actionability were measured using the Patient Education Materials Assessment Tool (PEMAT). Effects of authorship and geographical variation were determined using Fischer exact and Kruskal-Wallis tests. We identified 148 unique PEM. Only 31 (21%) sites adhered to the recommended <8th grade reading level. Most PEM did not contain recommended graphics (14%), checklists (2%), or summaries (6%). The PEMAT understandability score for academic PEM was higher than private (P = .02) and unaffiliated PEM (P = .01). No websites had inaccurate content. Only 2 PEM sites (1%) included all essential content (stop anticoagulants, antibiotics, need for urinalysis, biopsy pain, when to resume activity, and bleeding complications). Few significant differences based on geographic region were observed for word count, readability, PEMAT scores, or content. Transrectal ultrasound-guided prostate biopsy PEM adhere poorly to guidelines for easy-to-understand materials. Most PEM lack vital information and are written at a reading level that is too complex for patient comprehension. The urology community can construct better websites by consulting PEM advisory materials and providing nontechnical language, figures, and specific instructions. Published by Elsevier Inc.

  5. Can Prostate Imaging Reporting and Data System Version 2 reduce unnecessary prostate biopsies in men with PSA levels of 4-10 ng/ml?

    PubMed

    Xu, Ning; Wu, Yu-Peng; Chen, Dong-Ning; Ke, Zhi-Bin; Cai, Hai; Wei, Yong; Zheng, Qing-Shui; Huang, Jin-Bei; Li, Xiao-Dong; Xue, Xue-Yi

    2018-05-01

    To explore the value of Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2) for predicting prostate biopsy results in patients with prostate specific antigen (PSA) levels of 4-10 ng/ml. We retrospectively reviewed multi-parameter magnetic resonance images from 528 patients with PSA levels of 4-10 ng/ml who underwent transrectal ultrasound-guided prostate biopsies between May 2015 and May 2017. Among them, 137 were diagnosed with prostate cancer (PCa), and we further subdivided them according to pathological results into the significant PCa (S-PCa) and insignificant significant PCa (Ins-PCa) groups (121 cases were defined by surgical pathological specimen and 16 by biopsy). Age, PSA, percent free PSA, PSA density (PSAD), prostate volume (PV), and PI-RADS score were collected. Logistic regression analysis was performed to determine predictors of pathological results. Receiver operating characteristic curves were constructed to analyze the diagnostic value of PI-RADS v2 in PCa. Multivariate analysis indicated that age, PV, percent free PSA, and PI-RADS score were independent predictors of biopsy findings, while only PI-RADS score was an independent predictor of S-PCa (P < 0.05). The areas under the receiver operating characteristic curve for diagnosing PCa with respect to age, PV, percent free PSA, and PI-RADS score were 0.570, 0.430, 0.589 and 0.836, respectively. The area under the curve for diagnosing S-PCa with respect to PI-RADS score was 0.732. A PI-RADS score of 3 was the best cutoff for predicting PCa, and 4 was the best cutoff for predicting S-PCa. Thus, 92.8% of patients with PI-RADS scores of 1-2 would have avoided biopsy, but at the cost of missing 2.2% of the potential PCa cases. Similarly, 83.82% of patients with a PI-RADS score ≤ 3 would have avoided biopsy, but at the cost of missing 3.3% of the potential S-PCa cases. PI-RADS v2 could be used to reduce unnecessary prostate biopsies in patients with PSA levels of 4-10 ng/ml.

  6. Core needle biopsy of soft tissue tumors, CEUS vs US guided: a pilot study.

    PubMed

    Coran, Alessandro; Di Maggio, Antonio; Rastrelli, Marco; Alberioli, Enrico; Attar, Shady; Ortolan, Paolo; Bortolanza, Carlo; Tosi, Annalisa; Montesco, Maria Cristina; Bezzon, Elisabetta; Rossi, Carlo Riccardo; Stramare, Roberto

    2015-12-01

    The purpose of this study was to evaluate the usefulness of contrast-enhanced ultrasonography (CEUS) in the bioptic sampling of soft tissue tumors (STT) compared with unenhanced ultrasonography alone. This is a prospective longitudinal study of 40 patients subjected to ultrasonography (US)-guided core needle biopsy (CNB) to characterize a suspected STT. Three series of bioptic samplings were carried out on each patient, respectively using unenhanced US alone and CEUS in both the areas of the tumor enhanced or not by the contrast medium. All bioptic samples underwent a histological evaluation and the results were analyzed by comparing the histology of the biopsy with the definitive diagnosis in 15 surgically excised samples. 27 (67.5 %) of the 40 patients completed the entire study procedure; in 19 cases (70.3 %) the three bioptic samplings gave unanimous results, also when compared to the surgical specimen; in seven cases (25.9 %) use of CEUS allowed to obtain additional or more accurate information about the mass in question, compared to simple US guidance without contrast; in one patient (3.7 %) sampling obtained using unenhanced ultrasonography guidance and in the areas enhanced by the contrast agent had precisely the same results of the surgical specimen. CEUS, due to its ability to evaluate microvascular areas, has proven to be a promising method in guiding bioptic sampling of soft tissue tumor, directing the needle to the most significant areas of the tumor. Given the small number of patients evaluated in our study, to achieve statistically significant results, it would be appropriate to obtain a larger sample size, since the very first results seem to be encouraging and to justify the increase of the population.

  7. The economic effect of using magnetic resonance imaging and magnetic resonance ultrasound fusion biopsy for prostate cancer diagnosis.

    PubMed

    Hutchinson, Ryan C; Costa, Daniel N; Lotan, Yair

    2016-07-01

    Prostate magnetic resonance imaging (MRI) is a maturing imaging modality that has been used to improve detection and staging of prostate cancer. The goal of this review is to evaluate the economic effect of the use of MRI and MRI fusion in the diagnosis of prostate cancer. A literature review was used to identify articles regarding efficacy and cost of MRI and MRI-guided biopsies. There are currently a limited number of studies evaluating cost of incorporating MRI into clinical practice. These studies are primarily models projecting cost estimates based on meta-analyses of the literature. There is considerable variance in the effectiveness of MRI-guided biopsies, both cognitive and fusion, based on user experience, type of MRI (3T vs. 1.5T), use of endorectal coil and type of scoring system for abnormalities such that there is still potential for improvement in accuracy. There is also variability in assumed costs of incorporating MRI into clinical practice. The addition of MRI to the diagnostic algorithm for prostate cancer has caused a shift in how we understand the disease and in what tumors are found on initial and repeat biopsies. Further risk stratification may allow more men to pursue noncurative therapy, which in and of itself is cost-effective in properly selected men. As prostate cancer care comes under increasing scrutiny on a national level, there is pressure on providers to be more accurate in their diagnoses. This in turn can lead to additional testing including Multiparametric MRI, which adds upfront cost. Whether the additional cost of prostate MRI is warranted in detection of prostate cancer is an area of intense research. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Impact of obesity on the predictive accuracy of prostate-specific antigen density and prostate-specific antigen in native Korean men undergoing prostate biopsy.

    PubMed

    Kim, Jae Heon; Doo, Seung Whan; Yang, Won Jae; Lee, Kwang Woo; Lee, Chang Ho; Song, Yun Seob; Jeon, Yoon Su; Kim, Min Eui; Kwon, Soon-Sun

    2014-10-01

    To evaluate the impact of obesity on the biopsy detection of prostate cancer. We retrospectively reviewed data of 1182 consecutive Korean patients (≥50 years) with serum prostate-specific antigen levels of 3-10 ng/mL who underwent initial extended 12-cores biopsy from September 2009 to March 2013. Patients who took medications that were likely to influence the prostate-specific antigen level were excluded. Receiver operating characteristic curves were plotted for prostate-specific antigen and prostate-specific antigen density predicting cancer status among non-obese and obese men. A total of 1062 patients (mean age 67.1 years) were enrolled in the analysis. A total of 230 men (21.7%) had a positive biopsy. In the overall study sample, the area under the receiver operator characteristic curve of serum prostate-specific antigen for predicting prostate cancer on biopsy were 0.584 and 0.633 for non-obese and obese men, respectively (P = 0.234). However, the area under the curve for prostate-specific antigen density in predicting cancer status showed a significant difference (non-obese 0.696, obese 0.784; P = 0.017). There seems to be a significant difference in the ability of prostate-specific antigen density to predict biopsy results between non-obese and obese men. Obesity positively influenced the overall ability of prostate-specific antigen density to predict prostate cancer. © 2014 The Japanese Urological Association.

  9. Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses

    PubMed Central

    Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao

    2018-01-01

    Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650

  10. Optimization of real-time rigid registration motion compensation for prostate biopsies using 2D/3D ultrasound

    NASA Astrophysics Data System (ADS)

    Gillies, Derek J.; Gardi, Lori; Zhao, Ren; Fenster, Aaron

    2017-03-01

    During image-guided prostate biopsy, needles are targeted at suspicious tissues to obtain specimens that are later examined histologically for cancer. Patient motion causes inaccuracies when using MR-transrectal ultrasound (TRUS) image fusion approaches used to augment the conventional biopsy procedure. Motion compensation using a single, user initiated correction can be performed to temporarily compensate for prostate motion, but a real-time continuous registration offers an improvement to clinical workflow by reducing user interaction and procedure time. An automatic motion compensation method, approaching the frame rate of a TRUS-guided system, has been developed for use during fusion-based prostate biopsy to improve image guidance. 2D and 3D TRUS images of a prostate phantom were registered using an intensity based algorithm utilizing normalized cross-correlation and Powell's method for optimization with user initiated and continuous registration techniques. The user initiated correction performed with observed computation times of 78 ± 35 ms, 74 ± 28 ms, and 113 ± 49 ms for in-plane, out-of-plane, and roll motions, respectively, corresponding to errors of 0.5 ± 0.5 mm, 1.5 ± 1.4 mm, and 1.5 ± 1.6°. The continuous correction performed significantly faster (p < 0.05) than the user initiated method, with observed computation times of 31 ± 4 ms, 32 ± 4 ms, and 31 ± 6 ms for in-plane, out-of-plane, and roll motions, respectively, corresponding to errors of 0.2 ± 0.2 mm, 0.6 ± 0.5 mm, and 0.8 ± 0.4°.

  11. Concordance of Gleason grading with three-dimensional ultrasound systematic biopsy and biopsy core pre-embedding.

    PubMed

    van der Aa, Anouk A M A; Mannaerts, Christophe K; van der Linden, Hans; Gayet, Maudy; Schrier, Bart Ph; Mischi, Massimo; Beerlage, Harrie P; Wijkstra, Hessel

    2018-02-01

    To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens. Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129). The impact of 3D TRUS-guidance with pre-embedding on Gleason score (GS) concordance between biopsy and RP was evaluated using the κ-coefficient. Predictors of biopsy GS 6 upgrading were assessed using logistic regression models. Gleason concordance was comparable between the two cohorts with a κ = 0.44 for the 3D cohort, compared to κ = 0.42 for the 2D cohort. 3D TRUS-guidance with pre-embedding, did not significantly affect the risk of biopsy GS 6 upgrading in univariate and multivariate analysis. 3D TRUS-guidance with biopsy core pre-embedding did not improve Gleason concordance. Improved detection techniques are needed for recognition of low-grade disease upgrading.

  12. Ultrasound-guided chest biopsies.

    PubMed

    Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar

    2006-12-01

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.

  13. Infective complications in patients after transrectal ultrasound-guided prostate biopsy and the role of ciprofloxacin resistant Escherichia coli colonization in rectal flora.

    PubMed

    Hamarat, Mustafa Bilal; Tarhan, Fatih; Horuz, Rahim; Öcal, Gülfem Akengin; Demirkol, Mehmet Kutlu; Kafkaslı, Alper; Yazıcı, Özgür

    2017-06-01

    In the present study, we aimed to invastigate the ciprofloxacin resistance in rectal flora of the patients undergoing prostate biopsy in our department. Additionally, the possible effects of the presence of ciprofloxacin resistant bacteria in faecal flora on the risk of infective complications after the procedure as well as the effect of antibiotic prophylaxis on such infectious complications have been evaluated. A total of 142 patients undergoing transrectal ultrasound-guided prostate biopsy were included into the study program. Rectal swab samples were taken from all patients prior to biopsy. The presence of complications have been evaluated after a week following the biopsy procedure. Patients with fever were also evaluated. The possible correlation between the presence of ciprofloxacin-resistant bacteria in faecal flora and the risk of urinary tract infection development and the other complications were evaluated. E. coli bacteria were present in all cultures of rectal swab samples obtained from 142 patients prior to prostate biopsy. Of all these patients, while ciprofloxacin-resistant E. coli (CR E. coli ) grew in 76 (53.5%) patients; ciprofloxacin susceptible E. coli (CS E. coli ) was obtained in 66 (46.5%) patients. In 16 patients (11.3%), infectious complications were observed. While the infective complications were present in the 14.5% of patients with CR E. coli ; they were present in the 7.6% of patients with CS E. coli (p=0.295). High fever was observed in nine patients (6.3%). Of these nine patients, although six had CR E. coli growth as detected during culture sensitivity tests; three had CS E. coli growth in their rectal swab culture tests. Sepsis was observed in three (2.1%) of these patients with high fever. Ciprofloxacin-resistant E. coli grew in all of the rectal swab cultures obtained from these patients with sepsis. In the light of our findings we may say that, it will be appropriate to reconsider the ciprofloxacin prophylaxis and prefer to use

  14. Comparison of transrectal photoacoustic, Doppler, and magnetic resonance imaging for prostate cancer detection

    NASA Astrophysics Data System (ADS)

    Ishihara, Miya; Horiguchi, Akio; Shinmoto, Hiroshi; Tsuda, Hitoshi; Irisawa, Kaku; Wada, Takatsugu; Asano, Tomohiko

    2016-03-01

    Transrectal ultrasonography (TRUS) is the most popular imaging modality for diagnosing and treating prostate cancer. TRUS-guided prostate biopsy is mandatory for the histological diagnosis of patients with elevated serum prostatespecific antigen (PSA), but its diagnostic accuracy is not satisfactory due to TRUS's low resolution. As a result, a considerable number of patients are required to undergo an unnecessary repeated biopsy. Photoacoustic imaging (PAI) can be used to provide microvascular network imaging using hemoglobin as an intrinsic, optical absorption molecule. We developed an original TRUS-type PAI probe consisting of a micro-convex array transducer with an optical illumination system to provide superimposed PAI and ultrasound images. TRUS-type PAI has the advantage of having much higher resolution and greater contrast than does Doppler TRUS. The purpose of this study was to demonstrate the clinical feasibility of the transrectal PAI system. We performed a clinical trial to compare the image of the cancerous area obtained by transrectal PAI with that obtained by TRUS Doppler during prostate biopsy. The obtained prostate biopsy cores were stained with anti-CD34 antibodies to provide a microvascular distribution map. We also confirmed its consistency with PAI and pre-biopsy MRI findings. Our study demonstrated that transrectal identification of tumor angiogenesis under superimposed photoacoustic and ultrasound images was easier than that under TRUS alone. We recognized a consistent relationship between PAI and MRI findings in most cases. However, there were no correspondences in some cases.

  15. Gleason Score Determination with Transrectal Ultrasound-Magnetic Resonance Imaging Fusion Guided Prostate Biopsies--Are We Gaining in Accuracy?

    PubMed

    Lanz, Camille; Cornud, François; Beuvon, Frédéric; Lefèvre, Arnaud; Legmann, Paul; Zerbib, Marc; Delongchamps, Nicolas Barry

    2016-01-01

    We evaluated the accuracy of prostate magnetic resonance imaging- transrectal ultrasound targeted biopsy for Gleason score determination. We selected 125 consecutive patients treated with radical prostatectomy for a clinically localized prostate cancer diagnosed on magnetic resonance imaging-transrectal ultrasound targeted biopsy and/or systematic biopsy. On multiparametric magnetic resonance imaging each suspicious area was graded according to PI-RADS™ score. A correlation analysis between multiparametric magnetic resonance imaging and pathological findings was performed. Factors associated with determining the accuracy of Gleason score on targeted biopsy were statistically assessed. Pathological analysis of radical prostatectomy specimens detected 230 tumor foci. Multiparametric magnetic resonance imaging detected 151 suspicious areas. Of these areas targeted biopsy showed 126 cancer foci in 115 patients, and detected the index lesion in all of them. The primary Gleason grade, secondary Gleason grade and Gleason score of the 126 individual tumors were determined accurately in 114 (90%), 75 (59%) and 85 (67%) cases, respectively. Maximal Gleason score was determined accurately in 80 (70%) patients. Gleason score determination accuracy on targeted biopsy was significantly higher for low Gleason and high PI-RADS score tumors. Magnetic resonance imaging-transrectal ultrasound targeted biopsy allowed for an accurate estimation of Gleason score in more than two-thirds of patients. Gleason score misclassification was mostly due to a lack of accuracy in the determination of the secondary Gleason grade. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. The Prostate Health Index in predicting initial prostate biopsy outcomes in Asian men with prostate-specific antigen levels of 4-10 ng/mL.

    PubMed

    Ng, C F; Chiu, Peter K F; Lam, N Y; Lam, H C; Lee, Kim W M; Hou, Simon S M

    2014-04-01

    To investigate the role of the Prostate Health Index (phi) in prostate cancer (PCa) detection in patients with a prostate-specific antigen (PSA) level of 4-10 ng/mL receiving their first prostatic biopsy in an Asian population. This was a retrospective study of archived serum samples from patients enlisted in our tissue bank. Patients over 50 years old, with PSA level of 4-10 ng/mL, a negative digital rectal examination, and received their first prostatic biopsy between April 2008 and April 2013, were recruited. The serum sample collected before biopsy was retrieved for the measurement of various PSA derivatives and the phi value was calculated for each patient. The performance of these parameters in predicting the prostatic biopsy results was assessed. Two hundred and thirty consecutive patients, with 21 (9.13 %) diagnosed with PCa, were recruited for this study. Statistically significant differences between PCa patients and non-PCa patients were found for total PSA, PSA density, [-2]proPSA (p2PSA), free-to-total PSA ratio (%fPSA), p2PSA-to-free PSA ratio (%p2PSA), and phi. The areas under the curve of the receiver operating characteristic curve for total PSA, PSA density, %fPSA, %p2PSA, and phi were 0.547, 0.634, 0.654, 0.768, and 0.781, respectively. The phi was the best predictor of the prostatic biopsies results. At a sensitivity of 90 %, the use of the phi could have avoided unnecessary biopsies in 104 (45.2 %) patients. Use of the phi could improve the accuracy of PCa detection in patients with an elevated PSA level and thus avoid unnecessary prostatic biopsies.

  17. Electrical property sensing biopsy needle for prostate cancer detection.

    PubMed

    Mishra, V; Schned, A R; Hartov, A; Heaney, J A; Seigne, J; Halter, R J

    2013-11-01

    Significant electrical property differences have been demonstrated to exist between malignant and benign prostate tissues. We evaluated how well a custom designed clinically deployable electrical property sensing biopsy needle is able to discriminate between these tissue types in an ex vivo prostate model. An electrical impedance spectroscopy (EIS) sensing biopsy (Bx) needle was developed to record resistive (ρR) and reactive (ρX) components of electrical impedance from 100 Hz to 1 MHz. Standard twelve-core biopsy protocols were followed, in which the EIS-Bx device was used to gauge electrical properties prior to extracting tissue cores through biopsy needle firing from 36 ex vivo human prostates. Histopathological assessment of the cores was statistically compared to the impedance spectrum gauged from each core. The magnitudes of the mean resistive and reactive components were significantly higher in cancer tissues (P < 0.05). ROC curves showed that ρR at 63.09 kHz was optimal for discriminating cancer from benign tissues; this parameter had 75.4% specificity, 76.1% sensitivity, and ROC AUC of 0.779. Similarly, 251.1 kHz was optimal when using ρX to discriminate cancer from benign tissues; this parameter had a 77.9% specificity, 71.4% sensitivity, and ROC AUC of 0.79. Significant electrical property differences noted between benign and malignant prostate tissues suggest the potential efficacy an EIS-Bx device would provide for cancer detection in a clinical setting. By sensing a greater fraction of the prostate's volume in real-time, the EIS-Bx device has the potential to improve the accuracy of cancer grading and volume estimation made with current biopsy procedures. © 2013 Wiley Periodicals, Inc.

  18. Elastic Versus Rigid Image Registration in Magnetic Resonance Imaging-transrectal Ultrasound Fusion Prostate Biopsy: A Systematic Review and Meta-analysis.

    PubMed

    Venderink, Wulphert; de Rooij, Maarten; Sedelaar, J P Michiel; Huisman, Henkjan J; Fütterer, Jurgen J

    2016-07-29

    The main difference between the available magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion platforms for prostate biopsy is the method of image registration being either rigid or elastic. As elastic registration compensates for possible deformation caused by the introduction of an ultrasound probe for example, it is expected that it would perform better than rigid registration. The aim of this meta-analysis is to compare rigid with elastic registration by calculating the detection odds ratio (OR) for both subgroups. The detection OR is defined as the ratio of the odds of detecting clinically significant prostate cancer (csPCa) by MRI-TRUS fusion biopsy compared with systematic TRUS biopsy. Secondary objectives were the OR for any PCa and the OR after pooling both registration techniques. The electronic databases PubMed, Embase, and Cochrane were systematically searched for relevant studies according to the Preferred Reporting Items for Systematic Review and Meta-analysis Statement. Studies comparing MRI-TRUS fusion and systematic TRUS-guided biopsies in the same patient were included. The quality assessment of included studies was performed using the Quality Assessment of Diagnostic Accuracy Studies version 2. Eleven papers describing elastic and 10 describing rigid registration were included. Meta-analysis showed an OR of csPCa for elastic and rigid registration of 1.45 (95% confidence interval [CI]: 1.21-1.73, p<0.0001) and 1.40 (95% CI: 1.13-1.75, p=0.002), respectively. No significant difference was seen between the subgroups (p=0.83). Pooling subgroups resulted in an OR of 1.43 (95% CI: 1.25-1.63, p<0.00001). No significant difference was identified between rigid and elastic registration for MRI-TRUS fusion-guided biopsy in the detection of csPCa; however, both techniques detected more csPCa than TRUS-guided biopsy alone. We did not identify any significant differences in prostate cancer detection between two distinct magnetic resonance

  19. A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

    NASA Astrophysics Data System (ADS)

    Mitra, Jhimli; Srikantha, Abhilash; Sidibé, Désiré; Martí, Robert; Oliver, Arnau; Lladó, Xavier; Ghose, Soumya; Vilanova, Joan C.; Comet, Josep; Meriaudeau, Fabrice

    2012-02-01

    This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to perform an analysis based on shape and information theory to reach close enough to the actual MR slice as validated by experts. The Bhattacharyya distance is used to find point correspondences between shape-context representations of the prostate contours. Thereafter, Chi-square distance is used to find out those MR slices where the prostates closely match with that of the TRUS slice. Normalized Mutual Information (NMI) values of the TRUS slice with each of the axial MR slices are computed after rigid alignment and consecutively a strategic elimination based on a set of rules between the Chi-square distances and the NMI leads to the required MR slice. We validated our method for TRUS axial slices of 15 patients, of which 11 results matched at least one experts validation and the remaining 4 are at most one slice away from the expert validations.

  20. Endothelin-1 Expression in Prostate Needle Biopsy Specimens Correlated With Aggressiveness of Prostatic Cancer

    PubMed Central

    Asgari, Mojgan; Eftekhar, Elham; Abolhasani, Maryam; Shahrokh, Hossein

    2017-01-01

    Background & Objective: As the prostate adenocarcinoma is one of the most common malignant tumors in males, looking for a marker to effectively predict aggressiveness and metastatic potential in an apparently localized cancer in initial needle biopsy specimens can help the clinicians to make more appropriate decision for treatment, planning, and choosing appropriate targeted therapy. The present study assessed the value of Endothelin-1 expression to predict prognosis of prostatic cancer Methods: In a cross sectional study, 83 patients who underwent radical prostatectomy in Hasheminejad Kidney Center in 2008 through 2012 were assigned to two groups including 43 with and 40 without extra-prostatic extension (EPE). Endothelin-1 staining was performed on Paraffin Embedded blocks of preoperative needle biopsies. Results: The expression of Endothelin-1 increased in 72% of patients in the group with EPE (P<0.001). The group with Endothelin-1 positivity showed higher serum level of prostate specific antigen (PSA) (p = 0.039). Endothelin-1 expression was positive in 67% of patients with perineurial invasion (P<0.001). Adjusting the baseline variables of PSA and PN in a multivariable logistic regression model, the Endothelin-1 positivity could effectively predict EPE in patients with prostatic cancer (OR: 5.46, p = 0.010). Conclusion: Correlation of Endothelin-1 expression in needle biopsy specimens in expected with extra-prostatic extension of tumor in radical prostatectomy specimens, perineurial invasion and serum PSA level at the time of diagnosis. PMID:29515640

  1. Hot biopsy forceps vs. endoscopic ultrasonography in determining the depth of gastric epithelial neoplasia: a simple novel method to decide whether or not to perform endoscopic submucosal dissection.

    PubMed

    Huikai, Li; Enqiang, Linghu

    2013-01-01

    It is of vital importance to determine the depth of lesions to be treated by endoscopic submucosal dissection. This study aimed to compare the accuracy of using hot biopsy forceps method with endoscopic ultrasonography for determination of the depth of gastric epithelial neoplasia. Hot biopsy forceps method and/or endoscopic ultrasonography were used to determine the depth of lesions in 27 patients. With hot biopsy forceps method, we assumed a lesion completely lifted up by a hot biopsy forceps to be confined to the mucosal layer, and one partly lifted up to be located beyond the mucosal layer. The accuracy of hot biopsy forceps method and endoscopic ultrasonography in determining the depth of lesions were compared. Of the 27 patients, 25 underwent endoscopic submucosal dissection and 2 underwent surgery. The total accuracy of hot biopsy forceps method in determining the depth of lesions was 92.6% and that of endoscopic ultrasonography was 81.8%. Overestimation of hot biopsy forceps method and endoscopic ultrasonography were 3.7% vs. 13.6%, respectively. The sensitivity and the specificity of hot biopsy forceps method were 95.5% and 80.0% and those of EUS were 83.3% and 75.0%. Hot biopsy forceps method has a trend towards higher accuracy and lower overestimation than endoscopic ultrasonography.

  2. Effects of increasing the PSA cutoff to perform additional biomarker tests before prostate biopsy.

    PubMed

    Nordström, Tobias; Adolfsson, Jan; Grönberg, Henrik; Eklund, Martin

    2017-10-03

    Multi-step testing might enhance performance of the prostate cancer diagnostic pipeline. Using PSA >1 ng/ml for first-line risk stratification and the Stockholm 3 Model (S3M) blood-test >10% risk of Gleason Score > 7 prostate cancer to inform biopsy decisions has been suggested. We aimed to determine the effects of changing the PSA cutoff to perform reflex testing with S3M and the subsequent S3M cutoff to recommend prostate biopsy while maintaining the sensitivity to detect Gleason Score ≥ 7 prostate cancer. We used data from the prospective, population-based, paired, diagnostic Stockholm 3 (STHLM3) study with participants invited by date of birth from the Swedish Population Register during 2012-2014. All participants underwent testing with PSA and S3M (a combination of plasma protein biomarkers [PSA, free PSA, intact PSA, hK2, MSMB, MIC1], genetic polymorphisms, and clinical variables [age, family, history, previous prostate biopsy, prostate exam]). Of 47,688 men in the STHLM3 main study, we used data from 3133 men with S3M >10% and prostate biopsy data. Logistic regression models were used to calculate prostate cancer detection rates and proportion saved biopsies. 44.2%, 62.5% and 67.9% of the participants had PSA <1, <1.5 and <1.7 ng/ml, respectively. Increasing the PSA cut-off for additional work-up from 1 ng/ml to 1.5 ng/ml would thus save 18.3% of the performed tests, 4.9% of the biopsies and 1.3% (10/765) of Gleason Grade ≥ 7 cancers would be un-detected. By lowering the S3M cutoff to recommend biopsy, sensitivity to high-grade prostate cancer can be restored, to the cost of increasing the number of performed biopsies modestly. The sensitivity to detect prostate cancer can be maintained when using different PSA cutoffs to perform additional testing. Biomarker cut-offs have implications on number of tests and prostate biopsies performed. A PSA cutoff of 1.5 ng/ml to perform additional testing such as the S3M test might be considered. ISRCTN

  3. Ultrasound-Guided Abrams Pleural Biopsy vs CT-Guided Tru-Cut Pleural Biopsy in Malignant Pleural Disease, a 3-Year Follow-up Study.

    PubMed

    Sivakumar, Parthipan; Jayaram, Deepak; Rao, Deepak; Dhileepan, Vignesh; Ahmed, Irfan; Ahmed, Liju

    2016-12-01

    Conventional Abrams biopsy shows low sensitivity in suspected malignant pleural disease. There are limited data on the improvement in sensitivity by adding in image guidance. This retrospective study compares the diagnostic sensitivity of Abrams biopsy using ultrasound guidance with CT-guided Tru-Cut biopsy in suspected malignant pleural disease. Data were collected from 2006 to 2012 of patients who underwent image-guided biopsies for suspected non-tuberculous pleural disease. Data were collected on the result of the initial biopsy and final patient diagnosis as of June 2015. Sixty-three patients underwent image-guided Abrams biopsy and 29 underwent CT-guided Tru-Cut biopsies. The sensitivity of Abrams was 71.43 % compared to 75 % in the CT-guided Tru-Cut group. Specificity was 100 % in both groups. Image-guided Abrams biopsies demonstrate comparable diagnostic sensitivity in malignant pleural disease to CT-guided Tru-Cut biopsy.

  4. Magnetic resonance imaging-ultrasound fusion biopsy for prediction of final prostate pathology.

    PubMed

    Le, Jesse D; Stephenson, Samuel; Brugger, Michelle; Lu, David Y; Lieu, Patricia; Sonn, Geoffrey A; Natarajan, Shyam; Dorey, Frederick J; Huang, Jiaoti; Margolis, Daniel J A; Reiter, Robert E; Marks, Leonard S

    2014-11-01

    We explored the impact of magnetic resonance imaging-ultrasound fusion prostate biopsy on the prediction of final surgical pathology. A total of 54 consecutive men undergoing radical prostatectomy at UCLA after fusion biopsy were included in this prospective, institutional review board approved pilot study. Using magnetic resonance imaging-ultrasound fusion, tissue was obtained from a 12-point systematic grid (mapping biopsy) and from regions of interest detected by multiparametric magnetic resonance imaging (targeted biopsy). A single radiologist read all magnetic resonance imaging, and a single pathologist independently rereviewed all biopsy and whole mount pathology, blinded to prior interpretation and matched specimen. Gleason score concordance between biopsy and prostatectomy was the primary end point. Mean patient age was 62 years and median prostate specific antigen was 6.2 ng/ml. Final Gleason score at prostatectomy was 6 (13%), 7 (70%) and 8-9 (17%). A tertiary pattern was detected in 17 (31%) men. Of 45 high suspicion (image grade 4-5) magnetic resonance imaging targets 32 (71%) contained prostate cancer. The per core cancer detection rate was 20% by systematic mapping biopsy and 42% by targeted biopsy. The highest Gleason pattern at prostatectomy was detected by systematic mapping biopsy in 54%, targeted biopsy in 54% and a combination in 81% of cases. Overall 17% of cases were upgraded from fusion biopsy to final pathology and 1 (2%) was downgraded. The combination of targeted biopsy and systematic mapping biopsy was needed to obtain the best predictive accuracy. In this pilot study magnetic resonance imaging-ultrasound fusion biopsy allowed for the prediction of final prostate pathology with greater accuracy than that reported previously using conventional methods (81% vs 40% to 65%). If confirmed, these results will have important clinical implications. Copyright © 2014 American Urological Association Education and Research, Inc. Published by

  5. The Real Practice of Antibiotic Prophylaxis for Prostate Biopsy in Korea Where the Prevalence of Quinolone-Resistant Escherichia coli Is High

    PubMed Central

    Kim, Dae Hyun; Bae, Sang Rak; Choi, Woo Suk; Paick, Sung Hyun; Kim, Hyeong Gon; Loh, Yong Soo

    2014-01-01

    Purpose Transrectal ultrasonography-guided prostate biopsy (TRUS-Bx) is an essential procedure for diagnosing prostate cancer. The American Urological Association (AUA) Guideline recommends fluoroquinolone alone for 1 day during TRUS-Bx. However, this recommendation may not be appropriate in regions where the prevalence of quinolone-resistant Escherichia coli is high. We investigated the real practice of antibiotic prophylaxis for TRUS-Bx in Korea. Materials and Methods A total of 77 hospitals performing TRUS-Bx were identified and an e-mail was sent to the Urology Department of those hospitals. The questions in the e-mail included the choice of antibiotics before and after the procedure and the duration of antibiotic therapy after TRUS-Bx. Results A total of 54 hospitals (70.0%) responded to the e-mail. Before TRUS-Bx, all hospitals administered intravenous antibiotic prophylaxis. The percentage of hospitals that used quinolone, cephalosporin, and aminoglycoside alone was 48.1%, 20.4%, and 9.3%, respectively. The percentage of hospitals that used two or more antibiotics was 22.2%. After biopsy, all 54 hospitals prescribed oral antibiotics. The percentage of hospitals that prescribed quinolone alone, cephalosporin alone, or a combination of two or more antibiotics was 77.8%, 20.4%, and 1.8%, respectively. The duration of antibiotic use was more than 3 days in most hospitals (79.6%). Only four hospitals (7.4%) followed the AUA recommendation of a 1-day regimen. Conclusions The AUA recommendation was not followed by most hospitals in Korea. This clinical behavior might reflect the high quinolone resistance rate in Korea, and further studies on the most efficient prophylactic antibiotics after TRUS-Bx in Korea are warranted. PMID:25237461

  6. The real practice of antibiotic prophylaxis for prostate biopsy in Korea where the prevalence of quinolone-resistant Escherichia coli is high.

    PubMed

    Kim, Dae Hyun; Bae, Sang Rak; Choi, Woo Suk; Park, Hyoung Keun; Paick, Sung Hyun; Kim, Hyeong Gon; Loh, Yong Soo

    2014-09-01

    Transrectal ultrasonography-guided prostate biopsy (TRUS-Bx) is an essential procedure for diagnosing prostate cancer. The American Urological Association (AUA) Guideline recommends fluoroquinolone alone for 1 day during TRUS-Bx. However, this recommendation may not be appropriate in regions where the prevalence of quinolone-resistant Escherichia coli is high. We investigated the real practice of antibiotic prophylaxis for TRUS-Bx in Korea. A total of 77 hospitals performing TRUS-Bx were identified and an e-mail was sent to the Urology Department of those hospitals. The questions in the e-mail included the choice of antibiotics before and after the procedure and the duration of antibiotic therapy after TRUS-Bx. A total of 54 hospitals (70.0%) responded to the e-mail. Before TRUS-Bx, all hospitals administered intravenous antibiotic prophylaxis. The percentage of hospitals that used quinolone, cephalosporin, and aminoglycoside alone was 48.1%, 20.4%, and 9.3%, respectively. The percentage of hospitals that used two or more antibiotics was 22.2%. After biopsy, all 54 hospitals prescribed oral antibiotics. The percentage of hospitals that prescribed quinolone alone, cephalosporin alone, or a combination of two or more antibiotics was 77.8%, 20.4%, and 1.8%, respectively. The duration of antibiotic use was more than 3 days in most hospitals (79.6%). Only four hospitals (7.4%) followed the AUA recommendation of a 1-day regimen. The AUA recommendation was not followed by most hospitals in Korea. This clinical behavior might reflect the high quinolone resistance rate in Korea, and further studies on the most efficient prophylactic antibiotics after TRUS-Bx in Korea are warranted.

  7. The predictive value of 2-year posttreatment biopsy after prostate cancer radiotherapy for eventual biochemical outcome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vance, Waseet; Tucker, Susan L.; Crevoisier, Renaud de

    2007-03-01

    Purpose: To determine the value of a 2-year post-radiotherapy (RT) prostate biopsy for predicting eventual biochemical failure in patients who were treated for localized prostate cancer. Methods and Materials: This study comprised 164 patients who underwent a planned 2-year post-RT prostate biopsy. The independent prognostic value of the biopsy results for forecasting eventual biochemical outcome and overall survival was tested with other factors (the Gleason score, 1992 American Joint Committee on Cancer tumor stage, pretreatment prostate-specific antigen level, risk group, and RT dose) in a multivariate analysis. The current nadir + 2 (CN + 2) definition of biochemical failure wasmore » used. Patients with rising prostate-specific antigen (PSA) or suspicious digital rectal examination before the biopsy were excluded. Results: The biopsy results were normal in 78 patients, scant atypical and malignant cells in 30, carcinoma with treatment effect in 43, and carcinoma without treatment effect in 13. Using the CN + 2 definition, we found a significant association between biopsy results and eventual biochemical failure. We also found that the biopsy status provides predictive information independent of the PSA status at the time of biopsy. Conclusion: A 2-year post-RT prostate biopsy may be useful for forecasting CN + 2 biochemical failure. Posttreatment prostate biopsy may be useful for identifying patients for aggressive salvage therapy.« less

  8. MRI Fusion-Targeted Transrectal Prostate Biopsy and the Role of Prostate-Specific Antigen Density and Prostate Health Index for the Detection of Clinically Significant Prostate Cancer in Southeast Asian Men.

    PubMed

    Tan, Teck Wei; Png, Keng Siang; Lee, Chau Hung; Yuwono, Arianto; Yeow, Yuyi; Chong, Kian Tai; Lee, Yee Mun; Tan, Cher Heng; Tan, Yung Khan

    2017-11-01

    To test the hypothesis that targeted biopsy has a higher detection rate for clinically significant prostate cancer (csPCa) than systematic biopsy. We defined csPCa as any Gleason sum ≥7 cancer. In patients with Prostate Imaging Reporting and Data System (PI-RADS) 3 lesions, to determine if factors, such as prostate-specific antigen density (PSAD) and prostate health index (PHI), can predict csPCa and help select patients for biopsy. We report the first series of targeted biopsies in Southeast Asian men, with comparison against systematic biopsy. Consecutive patients were registered into a prospective institutional review board-approved database in our institution. We reviewed patients who underwent biopsy from May 2016 to June 2017. Inclusion criteria for our study were patients with at least one PI-RADS ≥3, and who underwent both targeted and systematic biopsies in the same sitting. There were 115 patients in the study, of whom 74 (64.3%) had a previous negative systematic biopsy. Targeted biopsies detected significantly less Gleason 6 cancers than systematic biopsies (p < 0.01), and demonstrated significantly higher sensitivity, specificity, positive predictive value, and negative predictive value (NPV) for the detection of csPCa. For patients with PI-RADS 3 lesions, PHI and PSAD were found to be the best predictors for csPCa. PSAD <0.10 ng/mL/mL had an NPV of 93% and sensitivity of 92%, while allowing 20% of patients to avoid biopsy. PHI cutoff of <27 would allow 34% of patients to avoid biopsy, with both sensitivity and NPV of 100%. Targeted prostate biopsies were found to be significantly superior to systematic biopsies for the detection of csPCa, while detecting less Gleason 6 cancer. Usage of PSAD and PHI cutoff levels in patients with PI-RADS 3 lesions may enable a number of patients to avoid unnecessary biopsy.

  9. Antibiotic prophylaxis and complications following prostate biopsies - a systematic review.

    PubMed

    Klemann, Nina; Helgstrand, John Thomas; Brasso, Klaus; Vainer, Ben; Iversen, Peter; Røder, Martin Andreas

    2017-01-01

    Transrectal ultrasound-guided biopsies (TRUS-gb) are associated with both mild and serious complications. Prophylactic antibiotics reduce the risk of septicaemia and mortality; however, no international consensus exists on the timing and duration of antibiotics, including the optimal drug strategy. We reviewed the current evidence supporting use of prophylactic antibiotics and the risk of complications following prostate biopsies. This review was drafted in accordance with the Prisma Guidelines. The PubMed, Embase and Cochrane databases were searched. A total of 19 eligible trials were identified. One trial demonstrated a significant reduction in the risk of infection after biopsy and reported that oral ciprofloxacin as either a single-dose or a three-day regimen was superior to oral chloramphenicol and norfloxacin. Of three studies investigating the timing of the first dose of antibiotic, one study found that administration 24 h before biopsy versus administration immediately before reduced the relative risk of post-biopsy infection by 55%. Seven studies compared different durations of antibiotic prophylaxis. None showed any benefit from continuing prophylaxis beyond a single dose or a one-day regimen. Evidence supporting a specific antibiotic regimen for TRUS-gb prophylaxis is scarce. Widespread use of fluoroquinolone prophylaxis may be associated with an increase in resistant Escherichia coli strains, posing a potentially major health issue in the future.  .

  10. Percutaneous CT-guided biopsy of the spine: results of 430 biopsies

    PubMed Central

    Rimondi, Eugenio; Errani, Costantino; Bianchi, Giuseppe; Casadei, Roberto; Alberghini, Marco; Malaguti, Maria Cristina; Rossi, Giuseppe; Durante, Stefano; Mercuri, Mario

    2008-01-01

    Biopsies of lesions in the spine are often challenging procedures with significant risk of complications. CT-guided needle biopsies could lower these risks but uncertainties still exist about the diagnostic accuracy. Aim of this retrospective study was to evaluate the diagnostic accuracy of CT-guided needle biopsies for bone lesions of the spine. We retrieved the results of 430 core needle biopsies carried out over the past fifteen years at the authors’ institute and examined the results obtained. Of the 430 biopsies performed, in 401 cases the right diagnosis was made with the first CT-guided needle biopsy (93.3% accuracy rate). Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, inflammatory, and systemic pathologies. There were only 9 complications (5 transient paresis, 4 haematomas that resolved spontaneously) that had no influence on the treatment strategy, nor on the patient’s outcome. In conclusion we can assert that this technique is reliable and safe and should be considered the gold standard in biopsies of the spine. PMID:18463900

  11. Outbreak of fluoroquinolone-resistant Escherichia coli infections after transrectal ultrasound-guided biopsy of the prostate.

    PubMed

    Dumford, Donald; Suwantarat, Nuntra; Bhasker, Vineet; Kundrapu, Sirisha; Zabarsky, Trina F; Drawz, Paul; Zhu, Hui; Donskey, Curtis J

    2013-03-01

    We conducted an investigation after identifying a cluster of 4 serious infections following transrectal ultrasound-guided biopsy of the prostate (TRUBP) during a 2-month period. Veterans Affairs medical center. Patients with urinary tract infection (UTI) after TRUBP and time-matched controls with no evidence of infection. The incidence of UTI within 30 days after TRUBP was calculated from 2002 through 2010. We evaluated the correlation between infection with fluoroquinolone-resistant gram-negative bacilli (GNB) and fluoroquinolone resistance in outpatient Escherichia coli urinary isolates and performed a case-control study to determine risk factors for infection with fluoroquinolone-resistant GNB. Processes for TRUBP prophylaxis, procedures, and equipment sterilization were reviewed. An outbreak of UTI due to fluoroquinolone-resistant E. coli after TRUBP began 2 years before the cluster was identified and was correlated with increasing fluoroquinolone resistance in outpatient E. coli. No deficiencies were identified in equipment processing or biopsy procedures. Fluoroquinolone-resistant E. coli UTI after TRUBP was independently associated with prior infection with fluoroquinolone-resistant GNB (adjusted odds ratio, 20.8; P=.005). A prediction rule including prior UTI, hospitalization in the past year, and previous infection with fluoroquinolone-resistant GNB identified only 17 (49%) of 35 cases. The outbreak of fluoroquinolone-resistant E. coli infections after TRUBP closely paralleled rising rates of fluoroquinolone resistance among outpatient E. coli isolates. The delayed detection of the outbreak and the absence of sensitive predictors of infection suggest that active surveillance for infection after TRUBP is necessary in the context of increasing fluoroquinolone resistance in the United States.

  12. Prediagnostic prostate-specific antigen kinetics and the risk of biopsy progression in active surveillance patients.

    PubMed

    Iremashvili, Viacheslav; Barney, Shane L; Manoharan, Murugesan; Kava, Bruce R; Parekh, Dipen J; Punnen, Sanoj

    2016-04-01

    To analyze the association between prediagnostic prostate-specific antigen kinetics and the risk of biopsy progression in prostate cancer patients on active surveillance, and to study the effect of prediagnostic prostate-specific antigen values on the predictive performance of prostate-specific antigen velocity and prostate-specific antigen doubling time. The study included 137 active surveillance patients with two or more prediagnostic prostate-specific antigen levels measured over a period of at least 3 months. Two sets of analyses were carried out. First, the association between prostate-specific antigen kinetics calculated using only the prediagnostic prostate-specific antigen values and the risk of biopsy progression was studied. Second, using the same cohort of patients, the predictive value of prostate-specific antigen kinetics calculated using only post-diagnostic prostate-specific antigens and compared with that of prostate-specific antigen kinetics based on both pre- and post-diagnostic prostate-specific antigen levels was analyzed. Of 137 patients included in the analysis, 37 (27%) had biopsy progression over a median follow-up period of 3.2 years. Prediagnostic prostate-specific antigen velocity of more than 2 ng/mL/year and 3 ng/mL/year was statistically significantly associated with the risk of future biopsy progression. However, after adjustment for baseline prostate-specific antigen density, these associations were no longer significant. None of the tested prostate-specific antigen kinetics based on combined pre- and post-diagnostic prostate-specific antigen values were statistically significantly associated with the risk of biopsy progression. Historical prediagnostic prostate-specific antigens seems to be not clinically useful in patients diagnosed with low-risk prostate cancer on active surveillance. © 2016 The Japanese Urological Association.

  13. Povidone Iodine Rectal Preparation at Time of Prostate Needle Biopsy is a Simple and Reproducible Means to Reduce Risk of Procedural Infection.

    PubMed

    Raman, Jay D; Lehman, Kathleen K; Dewan, Kalyan; Kirimanjeswara, Girish

    2015-09-21

    Single institution and population-based studies highlight that infectious complications following transrectal ultrasound guided prostate needle biopsy (TRUS PNB) are increasing. Such infections are largely attributable to quinolone resistant microorganisms which colonize the rectal vault and are translocated into the bloodstream during the biopsy procedure. A povidone iodine rectal preparation (PIRP) at time of biopsy is a simple, reproducible method to reduce rectal microorganism colony counts and therefore resultant infections following TRUS PNB. All patients are administered three days of oral antibiotic therapy prior to biopsy. The PIRP technique involves initially positioning the patient in the standard manner for a TRUS PNB. Following digital rectal examination, 15 ml of a 10% solution of commercially available povidone iodine is mixed with 5 ml of 1% lidocaine jelly to create slurry. A 4 cmx4 cm sterile gauze is soaked in this slurry and then inserted into the rectal vault for 2 min after which it is removed. Thereafter, a disposable cotton gynecologic swab is used to paint both the perianal area and the rectal vault to a distance of 3 cm from the anus. The povidone iodine solution is then allowed to dry for 2-3 min prior to proceeding with standard transrectal ultrasonography and subsequent biopsy. This PIRP technique has been in practice at our institution since March of 2012 with an associated reduction of post-biopsy infections from 4.3% to 0.6% (p=0.02). The principal advantage of this prophylaxis regimen is its simplicity and reproducibility with use of an easily available, inexpensive agent to reduce infections. Furthermore, the technique avoids exposing patients to additional systemic antibiotics with potential further propagation of multi-drug resistant organisms. Usage of PIRP at TRUS PNB, however, is not applicable for patients with iodine or shellfish allergies.

  14. Prostate cancer detection in patients with prior negative biopsy undergoing cognitive-, robotic- or in-bore MRI target biopsy.

    PubMed

    Kaufmann, Sascha; Russo, Giorgio I; Bamberg, Fabian; Löwe, Lorenz; Morgia, Giuseppe; Nikolaou, Konstantin; Stenzl, Arnulf; Kruck, Stephan; Bedke, Jens

    2018-05-01

    To evaluate the detection rate among three different targeted biopsy approaches of robot-assisted MRI/TRUS fusion (RA-TB), mpMRI in-bore (MRGB), cognitive fusion guidance biopsy (COG-TB) for the detection of prostate cancer (PC) and clinically significant PC (csPC). Between 2014 and 2016, 156 patients with a lesion on mpMRI, performed in accordance with ESUR guidelines, due to cancer suspicion or on-going cancer suspicion after prior negative prostate biopsy, underwent targeted biopsy with RA-TB, MRGB or COG-TB. All lesions were rated according to PI-RADS v2. We compared detection rates between techniques. Models were constructed to predict the detection of overall PC and csPC and using a 1000 boot-strap sample. In the all cohort, 73, 45 and 38 patients underwent RA-TB, MRGB or COG-TB, respectively. Overall PC was found in 39 (52.42%), 23 (51.11%) and 11 (28.95%) (p = 0.04) patients of RA-TB, MRGB and COG-TB arm, respectively. As concerning the detection of csPC, it was found in 26 (35.62%),18 (40.0%) and 9 (23.68%) patients of RA-TB, MRGB and COG-TB arm (p = 0.27). Model 1 showed that RA-TB [OR: 10.08 (95% CI 1.95-51.97); p < 0.01] and MRGB [OR: 12.88 (95% CI 2.36-70.25); p < 0.01] were associated with overall PC detection in TB, while only MRGB was associated with csPC at TB (model 2) [OR: 5.72; (95% CI 1.40-23.35); p < 0.01]. The c-index for model 1 and model 2 was 0.86 and 0.85, respectively. We did not report significant complications between groups. In-bore biopsy and MRI/TRUS fusion-guided biopsy showed greater accuracy in detecting PC compared to cognitive fusion as modeled in a newly established normogram.

  15. Improving diagnostic accuracy of prostate carcinoma by systematic random map-biopsy.

    PubMed

    Szabó, J; Hegedûs, G; Bartók, K; Kerényi, T; Végh, A; Romics, I; Szende, B

    2000-01-01

    Systematic random rectal ultrasound directed map-biopsy of the prostate was performed in 77 RDE (rectal digital examination) positive and 25 RDE negative cases, if applicable. Hypoechoic areas were found in 30% of RDE positive and in 16% of RDE negative cases. The score for carcinoma in the hypoechoic areas was 6.5% in RDE positive and 0% in RDE negative cases, whereas systematic map biopsy detected 62% carcinomas in RDE positive, and 16% carcinomas in RDE negative patients. The probability of positive diagnosis of prostate carcinoma increased in parallel with the number of biopsy samples/case. The importance of systematic map biopsy is emphasized.

  16. Development and external multicenter validation of Chinese Prostate Cancer Consortium prostate cancer risk calculator for initial prostate biopsy.

    PubMed

    Chen, Rui; Xie, Liping; Xue, Wei; Ye, Zhangqun; Ma, Lulin; Gao, Xu; Ren, Shancheng; Wang, Fubo; Zhao, Lin; Xu, Chuanliang; Sun, Yinghao

    2016-09-01

    Substantial differences exist in the relationship of prostate cancer (PCa) detection rate and prostate-specific antigen (PSA) level between Western and Asian populations. Classic Western risk calculators, European Randomized Study for Screening of Prostate Cancer Risk Calculator, and Prostate Cancer Prevention Trial Risk Calculator, were shown to be not applicable in Asian populations. We aimed to develop and validate a risk calculator for predicting the probability of PCa and high-grade PCa (defined as Gleason Score sum 7 or higher) at initial prostate biopsy in Chinese men. Urology outpatients who underwent initial prostate biopsy according to the inclusion criteria were included. The multivariate logistic regression-based Chinese Prostate Cancer Consortium Risk Calculator (CPCC-RC) was constructed with cases from 2 hospitals in Shanghai. Discriminative ability, calibration and decision curve analysis were externally validated in 3 CPCC member hospitals. Of the 1,835 patients involved, PCa was identified in 338/924 (36.6%) and 294/911 (32.3%) men in the development and validation cohort, respectively. Multivariate logistic regression analyses showed that 5 predictors (age, logPSA, logPV, free PSA ratio, and digital rectal examination) were associated with PCa (Model 1) or high-grade PCa (Model 2), respectively. The area under the curve of Model 1 and Model 2 was 0.801 (95% CI: 0.771-0.831) and 0.826 (95% CI: 0.796-0.857), respectively. Both models illustrated good calibration and substantial improvement in decision curve analyses than any single predictors at all threshold probabilities. Higher predicting accuracy, better calibration, and greater clinical benefit were achieved by CPCC-RC, compared with European Randomized Study for Screening of Prostate Cancer Risk Calculator and Prostate Cancer Prevention Trial Risk Calculator in predicting PCa. CPCC-RC performed well in discrimination and calibration and decision curve analysis in external validation compared

  17. Association between HIV status and Positive Prostate Biopsy in a Study of U.S. Veterans

    PubMed Central

    Hsiao, Wayland; Anastasia, Katrina; Hall, John; Goodman, Michael; Rimland, David; Ritenour, Chad W. M.; Issa, Muta M.

    2009-01-01

    HIV infection is associated with increased incidence of malignancies, such as lymphomas and testicular cancers. We reviewed the relationship between HIV infection and prostate cancer in a contemporary series of prostate biopsy patients. The study is a retrospective analysis of consecutive prostate biopsies performed at a VA Medical Center. The indications for performing a prostate biopsy included an abnormal digital rectal examination and/or an elevated PSA. Patients were categorized according to their HIV status, biopsy results, and various demographic and clinical characteristics. Univariate and multivariate analyses compared distributions of HIV status, and various clinical and demographic characteristics. The adjusted measures of association between HIV status and positive biopsy were expressed as odds ratios (ORs) and corresponding 95% confidence intervals (CI). The likelihood of positive biopsy was significantly higher among 18 HIV-positive patients compared to patients with negative HIV tests (adjusted OR = 3.9; 95% CI: 1.3–11.5). In analyses restricted to prostate cancer patients, HIV-positive patients were not different from the remaining group with respect to their prostate cancer stage, PSA level, PSA velocity, PSA density, or Gleason grade. There is an association between HIV infection and prostate biopsy positive for carcinoma in a population referred for urologic workup. Further confirmation of this association by prospective studies may impact the current screening practices in HIV patients. PMID:19219374

  18. Repeat Prostate Biopsy Practice Patterns in a Statewide Quality Improvement Collaborative.

    PubMed

    Burks, Frank N; Hu, Jonathan C; Telang, Dinesh; Liu, Alice; Hawken, Scott; Montgomery, Zack; Linsell, Susan; Montie, James E; Miller, David C; Ghani, Khurshid R

    2017-08-01

    We examined rebiopsies in MUSIC (Michigan Urological Surgery Improvement Collaborative) to understand adherence to guidelines recommending repeat prostate biopsy in patients with multifocal high grade prostatic intraepithelial neoplasia or atypical small acinar proliferation. We analyzed data on men undergoing repeat biopsy, practice patterns and cancer detection rates. Multivariate regression modeling was used to calculate the proportion of patients undergoing rebiopsy. We used claims data to validate the treatment classification in MUSIC. To understand reasons for not performing rebiopsy we reviewed records of a sample of patients with atypical small acinar proliferation. We identified 5,375 men with a negative biopsy, of whom 411 (7.6%) underwent repeat biopsy. In 718 men with high grade prostatic intraepithelial neoplasia, 350 with atypical small acinar proliferation and 587 with high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation or atypical small acinar proliferation alone at initial biopsy the rebiopsy rate was 20.7%, 42.5% and 55.6%, respectively. The adjusted proportion of patients with rebiopsy in each practice ranged from 0% to 17.2% (p <0.001). The overall cancer detection rate at rebiopsy was 39.3%. It was highest after atypical small acinar proliferation (adjusted probability 0.39, 95% CI 0.30-0.48), and after high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation (adjusted probability 0.50, 95% CI 0.35-0.65). The greatest Gleason 7 or greatest detection rate of 41.1% was found in patients with high grade prostatic intraepithelial neoplasia and atypical small acinar proliferation. Chart review revealed that 45.5% of patients with atypical small acinar proliferation underwent prostate specific antigen testing instead of rebiopsy while 36% failed to undergo rebiopsy despite a recommendation. Rebiopsy rates vary in Michigan practices with relatively low use in men with high grade

  19. Biases in Recommendations for and Acceptance of Prostate Biopsy Significantly Affect Assessment of Prostate Cancer Risk Factors: Results From Two Large Randomized Clinical Trials

    PubMed Central

    Goodman, Phyllis J.; Till, Cathee; Schenk, Jeannette M.; Lucia, M. Scott; Thompson, Ian M.

    2016-01-01

    Purpose To identify factors related to who undergoes a prostate biopsy in a screened population and to estimate the impact of biopsy verification on risk factor–prostate cancer associations. Patients and Methods Men who were screened regularly from the placebo arms of two large prostate cancer prevention trials (Prostate Cancer Prevention Trial [PCPT] and Selenium and Vitamin E Cancer Prevention Trial [SELECT]) were examined to define incident prostate cancer cohorts. Because PCPT had an end-of-study biopsy, prostate cancer cases were categorized by a preceding prostate-specific antigen/digital rectal examination prompt (yes/no) and noncases by biopsy-proven negative status (yes v no). We estimated the association of risk factors (age, ethnicity, family history, body mass index, medication use) with prostate cancer and quantified differences in risk associations across cohorts. Results Men 60 to 69 years of age, those with benign prostatic hyperplasia, and those with a family history of prostate cancer were more likely, and those with a higher body mass index (≥ 25), diabetes, or a smoking history were less likely, to undergo biopsy, adjusting for age and longitudinal prostate-specific antigen and digital rectal examination. Medication use, education, and marital status also influenced who underwent biopsy. Some risk factor estimates for prostate cancer varied substantially across cohorts. Black (v other ethnicities) had odds ratios (ORs) that varied from 1.20 for SELECT (community screening standards, epidemiologic-like cohort) to 1.83 for PCPT (end-of-study biopsy supplemented with imputed end points). Statin use in SELECT provided an OR of 0.65 and statin use in in PCPT provided an OR of 0.99, a relative difference of 34%. Conclusion Among screened men enrolled in prostate cancer prevention trials, differences in risk factor estimates for prostate cancer likely underestimate the magnitude of bias found in other cohorts with varying screening and biopsy

  20. Outcomes of ultrasound guided renal mass biopsies.

    PubMed

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  1. A retrospective study: correlation of histologic inflammation in biopsy specimens of Chinese men undergoing surgery for benign prostatic hyperplasia with serum prostate-specific antigen.

    PubMed

    Song, Lingmin; Zhu, Yuchun; Han, Ping; Chen, Ni; Lin, Dao; Lai, Jianyu; Wei, Qiang

    2011-03-01

    To reveal the correlation between benign prostatic hyperplasia (BPH) histologic inflammation and serum prostate-specific antigen (sPSA) concentrations, and the possible mechanism. Patients underwent surgery at the Urology Department of West China Hospital of Sichuan University were retrospectively studied. Preoperative sPSA and transrectal ultrasonography were measured. According to the histopathological classification system for chronic prostatic inflammation proposed by the Chronic Prostatitis Collaborative Research Network (CPCRN) and the International Prostatitis Collaborative Network (IPCN), we classified the histologic sections of prostatic biopsy into glandular, periglandular, and stromal inflammation by the anatomical location of inflammatory infiltration. The glandular inflammation was graded according to the inflammatory aggressiveness. The periglandular and stromal inflammation were graded according to the inflammatory density. The correlation between histologic inflammation and sPSA was studied by a multiple regression model in conjunction with age and total prostatic volume. A total of 454 patients with exclusively BPH were analyzed. The periglandular inflammatory infiltration was the most common pattern (95.6%). Single regression analysis revealed that total prostatic volume, the aggressiveness of glandular inflammation, and the intensity of periglandular and stromal inflammation were correlated with sPSA. However, the multiple regression analysis revealed that only the total prostatic volume and the aggressiveness of glandular inflammation were correlated significantly with sPSA (R = .389, 0.289; P = .000). The aggressiveness of glandular inflammatory infiltration in BPH is a significant contributor to elevated sPSA levels. The theory of leakage may be the most reasonable mechanism to reveal the correlation morphologically. We should take inflammation into consideration when interpreting the abnormal elevating of sPSA levels. Copyright © 2011

  2. A new model consists of intravesical prostatic protrusion, prostate volume and serum prostatic-specific antigen in the evaluation of prostate cancer.

    PubMed

    Xu, Ding; Yu, Yongjiang; Zhu, Yunkai; Huang, Tao; Chen, Yaqing; Qi, Jun

    2014-04-01

    The Prostate-specific antigen (PSA) level is largely used to diagnose prostate cancer (PCa) in last decades. However, its specificity is low in patients with a PSA level ranging from 4.0 to 10.0 ng/ml. This study aims to define the correlation between intravesical prostatic protrusion (IPP) and PSA and to establish a new model to predict PCa. A total of 339 patients order than 45 years examined between October 2010 and June 2012 were enrolled. Eligible patients were recommended for transrectal ultrasonography (TRUS)-guided prostate biopsies after measuring total prostate volume (TPV), tranzisional zone volume (TZV) and IPP. The levels of total PSA (tPSA), free PSA (fPSA) were analyzed by using Hybritech calibrated Access tPSA and fPSA assays. A new mathematical model, named IPP removed PCa predicting score (IRPPS), consists of tPSA, TZV and IPP was established. The predictive accuracy of IRPPS, PSA density (PSAD), %PSA and tPSA were compared using receiver-operator characteristic (ROC) analysis. Eighty-six patients had PSA levels of 4.0-10.0 ng/ml. Twenty of them were diagnosed as PCa. Using ROC curves, the areas under the curve for IRPPS, PSAD and %PSA and tPSA were 0.786, 0.768 and 0.664 and 0.585, respectively. We suggested IPP grade had a significant relationship with serum tPSA levels. The predictive accuracy of IRPPS was higher than the other 3 indictors.

  3. Two-micrometer thulium laser resection of the prostate-tangerine technique in benign prostatic hyperplasia patients with previously negative transrectal prostate biopsy.

    PubMed

    Zhuo, Jian; Wei, Hai-Bin; Zhang, Fei; Liu, Hai-Tao; Zhao, Fu-Jun; Han, Bang-Min; Sun, Xiao-Wen; Xia, Shu-Jie

    2017-01-01

    The 2-μm thulium laser resection of the prostate-tangerine technique (TmLRP-TT) has been introduced as a minimally invasive treatment for benign prostatic hyperplasia (BPH). This study was undertaken to assess the clinical efficacy and safety of TmLRP-TT for the treatment of BPH patients with previously negative transrectal prostate biopsy. A prospective analysis of 51 patients with previously negative transrectal prostate biopsy who underwent surgical treatment using TmLRP-TT was performed from December 2011 to December 2013. Preoperative status, surgical details, and perioperative complications were recorded. The follow-up outcome was evaluated with subjective and objective tests at 1 and 6 months. TmLRP-TT was successfully completed in all patients. Mean prostate volume, operative duration, and catheterization time were 93.3 ± 37.9 ml, 69.5 ± 39.5 min, and 6.5 ± 1.3 days, respectively. The mean International Prostate Symptom Score, quality of life score, maximum urinary flow rate, and post-void residual urine volume changed notably at 6-month follow-up (22.5 ± 6.9 vs 6.1 ± 3.2, 4.8 ± 1.3 vs 1.1 ± 0.9, 7.3 ± 4.5 vs 18.9 ± 7.1 ml s-1 , and 148.7 ± 168.7 vs 28.4 ± 17.9 ml). Two (3.9%) patients required blood transfusion perioperatively, while 3 (5.9%) patients experienced transient hematuria postoperatively, and 2 (3.9%) patients received 3 days recatheterization due to clot retention. TmLRP-TT is a safe and effective minimally invasive technique for patients with previously negative transrectal prostate biopsy during the 6-month follow-up. This promising technology may be a feasible surgical method for previously negative transrectal prostate biopsy in the future.

  4. Two-micrometer thulium laser resection of the prostate-tangerine technique in benign prostatic hyperplasia patients with previously negative transrectal prostate biopsy

    PubMed Central

    Zhuo, Jian; Wei, Hai-Bin; Zhang, Fei; Liu, Hai-Tao; Zhao, Fu-Jun; Han, Bang-Min; Sun, Xiao-Wen; Jun-Lu; Xia, Shu-Jie

    2017-01-01

    The 2-μm thulium laser resection of the prostate-tangerine technique (TmLRP-TT) has been introduced as a minimally invasive treatment for benign prostatic hyperplasia (BPH). This study was undertaken to assess the clinical efficacy and safety of TmLRP-TT for the treatment of BPH patients with previously negative transrectal prostate biopsy. A prospective analysis of 51 patients with previously negative transrectal prostate biopsy who underwent surgical treatment using TmLRP-TT was performed from December 2011 to December 2013. Preoperative status, surgical details, and perioperative complications were recorded. The follow-up outcome was evaluated with subjective and objective tests at 1 and 6 months. TmLRP-TT was successfully completed in all patients. Mean prostate volume, operative duration, and catheterization time were 93.3 ± 37.9 ml, 69.5 ± 39.5 min, and 6.5 ± 1.3 days, respectively. The mean International Prostate Symptom Score, quality of life score, maximum urinary flow rate, and post-void residual urine volume changed notably at 6-month follow-up (22.5 ± 6.9 vs 6.1 ± 3.2, 4.8 ± 1.3 vs 1.1 ± 0.9, 7.3 ± 4.5 vs 18.9 ± 7.1 ml s−1, and 148.7 ± 168.7 vs 28.4 ± 17.9 ml). Two (3.9%) patients required blood transfusion perioperatively, while 3 (5.9%) patients experienced transient hematuria postoperatively, and 2 (3.9%) patients received 3 days recatheterization due to clot retention. TmLRP-TT is a safe and effective minimally invasive technique for patients with previously negative transrectal prostate biopsy during the 6-month follow-up. This promising technology may be a feasible surgical method for previously negative transrectal prostate biopsy in the future. PMID:26732107

  5. [The role of a single PCA3 test before a first negative prostate biopsy: 5-year follow-up].

    PubMed

    Bernardeau, S; Charles, T; Fromont-Hankard, G; Irani, J

    2017-04-01

    We report a 5-year follow-up of a cohort of patients who underwent a first prostate biopsy following a prostate cancer antigen 3 (PCA3) test. We reviewed consecutive patients who had in 2008 a single urinary PCA3 test using the Gen-Probe ® assay before a first prostate biopsy for a prostate-specific antigen (PSA) between 3 and 20ng/mL and/or a suspicious digital rectal examination. PCA3 performances were analyzed in 2008 and then in 2013 after taking into account the results of repeat biopsies. At initial biopsy in 2008, among the 125 patients study cohort, prostate cancer was diagnosed in 47 patients (37.6%). Abnormal digital rectal exam, PSA density, prostate volume and PCA3 score were significantly associated with prostate cancer diagnosis. PCA3 area under the curve of the receiver operating curve was 0.67 [95%CI: 0.57-0.76] with an optimal threshold of PCA3 in this sample of 24 units. During the 5-year follow-up, among the 78 patients with a negative prostate biopsy in 2008, 23 (29.5%) had a repeat prostate biopsy of whom 14 were diagnosed with prostate cancer. PCA3 score measured in 2008 was associated with prostate cancer diagnosis (P=0.002). All 9 patients with a negative repeat prostate biopsy had a PCA3 score below the cut-off while this was the case in only 2 patients among the 14 with a positive repeat prostate biopsy. The results of a single PCA3 test before a first prostate biopsy seems to be a useful aid in deciding whether to perform a repeat biopsy. 4. Copyright © 2017. Published by Elsevier Masson SAS.

  6. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    PubMed Central

    Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton

    2016-01-01

    Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003

  7. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  8. External validation of urinary PCA3-based nomograms to individually predict prostate biopsy outcome.

    PubMed

    Auprich, Marco; Haese, Alexander; Walz, Jochen; Pummer, Karl; de la Taille, Alexandre; Graefen, Markus; de Reijke, Theo; Fisch, Margit; Kil, Paul; Gontero, Paolo; Irani, Jacques; Chun, Felix K-H

    2010-11-01

    Prior to safely adopting risk stratification tools, their performance must be tested in an external patient cohort. To assess accuracy and generalizability of previously reported, internally validated, prebiopsy prostate cancer antigen 3 (PCA3) gene-based nomograms when applied to a large, external, European cohort of men at risk of prostate cancer (PCa). Biopsy data, including urinary PCA3 score, were available for 621 men at risk of PCa who were participating in a European multi-institutional study. All patients underwent a ≥10-core prostate biopsy. Biopsy indication was based on suspicious digital rectal examination, persistently elevated prostate-specific antigen level (2.5-10 ng/ml) and/or suspicious histology (atypical small acinar proliferation of the prostate, >/= two cores affected by high-grade prostatic intraepithelial neoplasia in first set of biopsies). PCA3 scores were assessed using the Progensa assay (Gen-Probe Inc, San Diego, CA, USA). According to the previously reported nomograms, different PCA3 score codings were used. The probability of a positive biopsy was calculated using previously published logistic regression coefficients. Predicted outcomes were compared to the actual biopsy results. Accuracy was calculated using the area under the curve as a measure of discrimination; calibration was explored graphically. Biopsy-confirmed PCa was detected in 255 (41.1%) men. Median PCA3 score of biopsy-negative versus biopsy-positive men was 20 versus 48 in the total cohort, 17 versus 47 at initial biopsy, and 37 versus 53 at repeat biopsy (all p≤0.002). External validation of all four previously reported PCA3-based nomograms demonstrated equally high accuracy (0.73-0.75) and excellent calibration. The main limitations of the study reside in its early detection setting, referral scenario, and participation of only tertiary-care centers. In accordance with the original publication, previously developed PCA3-based nomograms achieved high accuracy and

  9. Should reporting of peri-neural invasion and extra prostatic extension be mandatory in prostate cancer biopsies? correlation with outcome in biopsy cases treated conservatively

    PubMed Central

    Ahmad, Amar S.; Parameshwaran, Vishnu; Beltran, Luis; Fisher, Gabrielle; North, Bernard V.; Greenberg, David; Soosay, Geraldine; Møller, Henrik; Scardino, Peter; Cuzick, Jack; Berney, Daniel M.

    2018-01-01

    The identification of perineural invasion (PNI) and extraprostatic extension (ECE) in prostate cancer (PC) biopsies is time consuming and can be difficult. Although this is required information in many datasets, there is little evidence on their effect on outcome in patients treated conservatively. Cases of PC were identified from three cancer registries in the UK from men with clinically localized prostate cancer diagnosed by needle biopsy from 1990–2003. The endpoint was prostate cancer death (DOD). Patients treated radically within 6 months, those with objective evidence of metastases or who had prior hormone therapy were excluded. Follow-up was through cancer registries up until 2012. Deaths were divided into those from PC and those from other causes, according to WHO criteria. 988 biopsy cases (6522 biopsy cores) were centrally reviewed by three uropathologists and assigned a Gleason score and Grade Group (GG). The presence of both PNI and ECE was recorded. Of 988 patients, PNI was present in 288 (DOD = 75) and ECE in 23 (DOD = 5). On univariable analysis PNI was highly significantly associated with DOD (hazard ratio [HR] 2.28, 95% CI: 1.68, 3.1, log-rank test p-value = 4.8 × 10–8), but ECE was not (log-rank test p-value = 0.334). On multivariable analysis with GG, serum PSA (per 10%), clinical stage and extent of disease (per 10%), PNI lost significance (HR 1.16, 95% CI: 0.83, 1.63, likelihood ratio test p-value = 0.371). The utility of routinely examining prostate biopsies for ECE and PNI is doubtful as it is not independently associated with higher grade, stage or prognosis. PMID:29755671

  10. Should reporting of peri-neural invasion and extra prostatic extension be mandatory in prostate cancer biopsies? correlation with outcome in biopsy cases treated conservatively.

    PubMed

    Ahmad, Amar S; Parameshwaran, Vishnu; Beltran, Luis; Fisher, Gabrielle; North, Bernard V; Greenberg, David; Soosay, Geraldine; Møller, Henrik; Scardino, Peter; Cuzick, Jack; Berney, Daniel M

    2018-04-17

    The identification of perineural invasion (PNI) and extraprostatic extension (ECE) in prostate cancer (PC) biopsies is time consuming and can be difficult. Although this is required information in many datasets, there is little evidence on their effect on outcome in patients treated conservatively. Cases of PC were identified from three cancer registries in the UK from men with clinically localized prostate cancer diagnosed by needle biopsy from 1990-2003. The endpoint was prostate cancer death (DOD). Patients treated radically within 6 months, those with objective evidence of metastases or who had prior hormone therapy were excluded. Follow-up was through cancer registries up until 2012. Deaths were divided into those from PC and those from other causes, according to WHO criteria. 988 biopsy cases (6522 biopsy cores) were centrally reviewed by three uropathologists and assigned a Gleason score and Grade Group (GG). The presence of both PNI and ECE was recorded. Of 988 patients, PNI was present in 288 (DOD = 75) and ECE in 23 (DOD = 5). On univariable analysis PNI was highly significantly associated with DOD (hazard ratio [HR] 2.28, 95% CI: 1.68, 3.1, log-rank test p -value = 4.8 × 10 -8 ), but ECE was not (log-rank test p -value = 0.334). On multivariable analysis with GG, serum PSA (per 10%), clinical stage and extent of disease (per 10%), PNI lost significance (HR 1.16, 95% CI: 0.83, 1.63, likelihood ratio test p -value = 0.371). The utility of routinely examining prostate biopsies for ECE and PNI is doubtful as it is not independently associated with higher grade, stage or prognosis.

  11. Trans-rectal ultrasound visibility of prostate lesions identified by magnetic resonance imaging increases accuracy of image-fusion targeted biopsies.

    PubMed

    Ukimura, Osamu; Marien, Arnaud; Palmer, Suzanne; Villers, Arnauld; Aron, Manju; de Castro Abreu, Andre Luis; Leslie, Scott; Shoji, Sunao; Matsugasumi, Toru; Gross, Mitchell; Dasgupta, Prokar; Gill, Inderbir S

    2015-11-01

    To compare the diagnostic yield of targeted prostate biopsy using image-fusion of multi-parametric magnetic resonance (mp-MR) with real-time trans-rectal ultrasound (TRUS) for clinically significant lesions that are suspicious only on mp-MR versus lesions that are suspicious on both mp-MR and TRUS. Pre-biopsy MRI and TRUS were each scaled on a 3-point score: highly suspicious, likely, and unlikely for clinically significant cancer (sPCa). Using an MR-TRUS elastic image-fusion system (Koelis), a 127 consecutive patients with a suspicious clinically significant index lesion on pre-biopsy mp-MR underwent systematic biopsies and MR/US-fusion targeted biopsies (01/2010-09/2013). Biopsy histological outcomes were retrospectively compared with MR suspicion level and TRUS-visibility of the MR-suspicious lesion. sPCa was defined as biopsy Gleason score ≥7 and/or maximum cancer core length ≥5 mm. Targeted biopsies outperformed systematic biopsies in overall cancer detection rate (61 vs. 41 %; p = 0.007), sPCa detection rate (43 vs. 23 %; p = 0.0013), cancer core length (7.5 vs. 3.9 mm; p = 0.0002), and cancer rate per core (56 vs. 12 %; p < 0.0001), respectively. Highly suspicious lesions on mp-MR correlated with higher positive biopsy rate (p < 0.0001), higher Gleason score (p = 0.018), and greater cancer core length (p < 0.0001). Highly suspicious lesions on TRUS in corresponding to MR-suspicious lesion had a higher biopsy yield (p < 0.0001) and higher sPCa detection rate (p < 0.0001). Since majority of MR-suspicious lesions were also suspicious on TRUS, TRUS-visibility allowed selection of the specific MR-visible lesion which should be targeted from among the multiple TRUS suspicious lesions in each prostate. MR-TRUS fusion-image-guided biopsies outperformed systematic biopsies. TRUS-visibility of a MR-suspicious lesion facilitates image-guided biopsies, resulting in higher detection of significant cancer.

  12. Highly sensitive molecular diagnosis of prostate cancer using surplus material washed off from biopsy needles

    PubMed Central

    Bermudo, R; Abia, D; Mozos, A; García-Cruz, E; Alcaraz, A; Ortiz, Á R; Thomson, T M; Fernández, P L

    2011-01-01

    Introduction: Currently, final diagnosis of prostate cancer (PCa) is based on histopathological analysis of needle biopsies, but this process often bears uncertainties due to small sample size, tumour focality and pathologist's subjective assessment. Methods: Prostate cancer diagnostic signatures were generated by applying linear discriminant analysis to microarray and real-time RT–PCR (qRT–PCR) data from normal and tumoural prostate tissue samples. Additionally, after removal of biopsy tissues, material washed off from transrectal biopsy needles was used for molecular profiling and discriminant analysis. Results: Linear discriminant analysis applied to microarray data for a set of 318 genes differentially expressed between non-tumoural and tumoural prostate samples produced 26 gene signatures, which classified the 84 samples used with 100% accuracy. To identify signatures potentially useful for the diagnosis of prostate biopsies, surplus material washed off from routine biopsy needles from 53 patients was used to generate qRT–PCR data for a subset of 11 genes. This analysis identified a six-gene signature that correctly assigned the biopsies as benign or tumoural in 92.6% of the cases, with 88.8% sensitivity and 96.1% specificity. Conclusion: Surplus material from prostate needle biopsies can be used for minimal-size gene signature analysis for sensitive and accurate discrimination between non-tumoural and tumoural prostates, without interference with current diagnostic procedures. This approach could be a useful adjunct to current procedures in PCa diagnosis. PMID:22009027

  13. Does Core Length Taken per cc of Prostate Volume in Prostate Biopsy Affect the Diagnosis of Prostate Cancer?

    PubMed

    Deliktas, Hasan; Sahin, Hayrettin; Cetinkaya, Mehmet; Dere, Yelda; Erdogan, Omer; Baldemir, Ercan

    2016-08-01

    The aim of this study was to determine the minimal core length to be taken per cc of prostate volume for an effective prostate biopsy. A retrospective analysis was performed on the records of 379 patients who underwent a first prostate biopsy with 12 to 16 cores under transrectal ultrasound guidance between September 2012 and April 2015. For each patient, the core length per cc of the prostate and the percentage of sampled prostate volume were calculated, and these values were compared between the patients with and without prostate cancer. A total of 348 patients were included in the study. Cancer was determined in 26.4% of patients. The mean core length taken per cc of prostate and the percentage of sampled prostate volume were determined to be 3.40 ± 0.15 mm/cc (0.26%; range, 0.08-0.63 cc) in patients with cancer and 2.75 ± 0.08 mm/cc (0.20%; range, 0.04-0.66 cc) in patients without cancer (P = .000 and P = .000), respectively. Core length taken per cc of prostate of > 3.31 mm/cc was found to be related to an increase in the rates of prostate cancer diagnosis (odds ratio, 2.84; 95% confidence interval, 1.68-4.78). The rate of cancer determination for core length taken per cc of prostate of < 3.31 mm/cc was 19.9% and of > 3.31 mm/cc, 41.1%. Core length taken per cc of prostate and the percentage of sampled prostate volume are important morphometric parameters in the determination of prostate cancer. The results of study suggest a core length per cc of the prostate of > 3.31 mm/cc as a cutoff value for quality assurance. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. A population-based study on the association between educational length, prostate-specific antigen testing and use of prostate biopsies.

    PubMed

    Nordström, Tobias; Bratt, Ola; Örtegren, Joakim; Aly, Markus; Adolfsson, Jan; Grönberg, Henrik

    2016-01-01

    The aim of this study was to determine whether educational length affects prostate-specific antigen (PSA) testing and the time to prostate biopsy for men with raised PSA values. Using register data on all men in Stockholm County in 2013 (n = 1,052,841), the limited-duration point prevalence of PSA testing and time between test and prostate biopsy or repeat testing were analysed. Patterns of follow-up were assessed using Kaplan-Meier product limit estimators and Cox proportional hazard models. Educational length was categorized as short (≤ 9 years), intermediate (10-12 years) or long (≥ 13 years). PSA testing increased with educational length in all age groups. Among men aged 50-69 years, 61% with long and 54% with short education had had a PSA test within the preceding 10 years (p < 0.001). In men with PSA 4-10 ng/ml, 40% [95% confidence interval (CI) 38-41] with long and 27% (95% CI 26-29) with short education underwent a prostate biopsy within 12 months. After adjusting for PSA level and age, educational length was still associated with the chance of having a prostate biopsy in men with PSA 4-10 ng/ml (hazard ratio 1.22, 95% CI 1.12-1.31), but not in men with higher PSA values. PSA testing increased with educational length. Men with long education were more likely to have a prostate biopsy after an increased PSA value below 10 ng/ml than men with short education. These differences may contribute to the worse prostate cancer outcomes observed among men with lower socioeconomic status.

  15. Feasibility of Prostate Cancer Diagnosis by Transrectal Photo-acoustic Imaging

    DTIC Science & Technology

    2013-03-01

    prostate. Transrectal ultrasound has been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for...tool currently available for prostate cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the...developing an integrated approach between ultrasound and optical tomography, namely, transrectal ultrasound - guided diffuse optical tomography (TRUS

  16. Risk of hospitalization and death following prostate biopsy in Scotland.

    PubMed

    Brewster, D H; Fischbacher, C M; Nolan, J; Nowell, S; Redpath, D; Nabi, G

    2017-01-01

    To investigate the risk of hospitalization and death following prostate biopsy. Retrospective cohort study. Our study population comprised 10,285 patients with a record of first ever prostate biopsy between 2009 and 2013 on computerized acute hospital discharge or outpatient records covering Scotland. Using the general population as a comparison group, expected numbers of admissions/deaths were derived by applying age-, sex-, deprivation category-, and calendar year-specific rates of hospital admissions/deaths to the study population. Indirectly standardized hospital admission ratios (SHRs) and mortality ratios (SMRs) were calculated by dividing the observed numbers of admissions/deaths by expected numbers. Compared with background rates, patients were more likely to be admitted to hospital within 30 days (SHR 2.7; 95% confidence interval 2.4, 2.9) and 120 days (SHR 4.0; 3.8, 4.1) of biopsy. Patients with prior co-morbidity had higher SHRs. The risk of death within 30 days of biopsy was not increased significantly (SMR 1.6; 0.9, 2.7), but within 120 days, the risk of death was significantly higher than expected (SMR 1.9; 1.5, 2.4). The risk of death increased with age and tended to be higher among patients with prior co-morbidity. Overall risks of hospitalization and of death up to 120 days were increased both in men diagnosed and those not diagnosed with prostate cancer. Higher rates of adverse events in older patients and patients with prior co-morbidity emphasizes the need for careful patient selection for prostate biopsy and justifies ongoing efforts to minimize the risk of complications. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Prostate health index (phi) and prostate cancer antigen 3 (PCA3) significantly improve diagnostic accuracy in patients undergoing prostate biopsy.

    PubMed

    Perdonà, Sisto; Bruzzese, Dario; Ferro, Matteo; Autorino, Riccardo; Marino, Ada; Mazzarella, Claudia; Perruolo, Giuseppe; Longo, Michele; Spinelli, Rosa; Di Lorenzo, Giuseppe; Oliva, Andrea; De Sio, Marco; Damiano, Rocco; Altieri, Vincenzo; Terracciano, Daniela

    2013-02-15

    Prostate health index (phi) and prostate cancer antigen 3 (PCA3) have been recently proposed as novel biomarkers for prostate cancer (PCa). We assessed the diagnostic performance of these biomarkers, alone or in combination, in men undergoing first prostate biopsy for suspicion of PCa. One hundred sixty male subjects were enrolled in this prospective observational study. PSA molecular forms, phi index (Beckman coulter immunoassay), PCA3 score (Progensa PCA3 assay), and other established biomarkers (tPSA, fPSA, and %fPSA) were assessed before patients underwent a 18-core first prostate biopsy. The discriminating ability between PCa-negative and PCa-positive biopsies of Beckman coulter phi and PCA3 score and other used biomarkers were determined. One hundred sixty patients met inclusion criteria. %p2PSA (p2PSA/fPSA × 100), phi and PCA3 were significantly higher in patients with PCa compared to PCa-negative group (median values: 1.92 vs. 1.55, 49.97 vs. 36.84, and 50 vs. 32, respectively, P ≤ 0.001). ROC curve analysis showed that %p2PSA, phi, and PCA3 are good indicator of malignancy (AUCs = 0.68, 0.71, and 0.66, respectively). A multivariable logistic regression model consisting of both the phi index and PCA3 score allowed to reach an overall diagnostic accuracy of 0.77. Decision curve analysis revealed that this "combined" marker achieved the highest net benefit over the examined range of the threshold probability. phi and PCA3 showed no significant difference in the ability to predict PCa diagnosis in men undergoing first prostate biopsy. However, diagnostic performance is significantly improved by combining phi and PCA3. Copyright © 2012 Wiley Periodicals, Inc.

  18. Chronic baseline prostate inflammation is associated with lower tumor volume in men with prostate cancer on repeat biopsy: Results from the REDUCE study.

    PubMed

    Moreira, Daniel M; Nickel, J Curtis; Andriole, Gerald L; Castro-Santamaria, Ramiro; Freedland, Stephen J

    2015-09-01

    To evaluate whether baseline acute and chronic prostate inflammation among men with initial negative biopsy for prostate cancer (PC) is associated with PC volume at the 2-year repeat prostate biopsy in a clinical trial with systematic biopsies. Retrospective analysis of 886 men with negative baseline prostate biopsy and positive 2-year repeat biopsy in the Reduction by Dutasteride of PC Events (REDUCE) study. Acute and chronic inflammation and tumor volume were determined by central pathology. The association of baseline inflammation with 2-year repeat biopsy cancer volume was evaluated with linear and Poisson regressions controlling for demographics and laboratory variables. Chronic, acute inflammation, and both were detected in 531 (60%), 12 (1%), and 84 (9%) baseline biopsies, respectively. Acute and chronic inflammation were significantly associated with each other (P < 0.001). Chronic inflammation was associated with larger prostate (P < 0.001) and lower pre-repeat biopsy PSA (P = 0.01). At 2-year biopsy, baseline chronic inflammation was associated with lower mean tumor volume (2.07 µl vs. 3.15 µl; P = 0.001), number of biopsy cores involved (1.78 vs. 2.19; P < 0.001), percent of cores involved (17.8% vs. 22.8%; P < 0.001), core involvement (0.21 µl vs. 0.31 µl; P < 0.001), and overall percent tumor involvement (1.40% vs. 2.01%; P < 0.001). Results were unchanged in multivariable analysis. Baseline acute inflammation was not associated with any tumor volume measurement. In a cohort of men with 2-year repeat prostate biopsy positive for PC after a negative baseline biopsy, baseline chronic inflammation was associated with lower PC volume. © 2015 Wiley Periodicals, Inc.

  19. 7 to 10 years' follow-up of 573 patients with elevated prostate-specific antigen (>4 ng/mL) or/and suspected rectal examination: biopsies protocol and follow-up guides.

    PubMed

    Kravchick, Sergey; Cytron, Shmuel; Stepnov, Eugeny; Ben-Dor, David; Kravchenko, Yakov; Peled, Ronit

    2009-06-01

    In this study, we tried to design a scheme for performing transrectal ultrasonographic (TRUS)-biopsies that would be accurate and include the optimal number of cores. We included in this study 600 consecutive patients with suspicious findings on a per-rectum examination and/or an elevated prostate-specific antigen (PSA) (>4 ng/mL) level. Patients were followed for 7 to 10 years. In all patients, we took from 8 to 16 biopsy samples, according to the prostate volume, from the lateral aspects. In the second session, the biopsy samples were taken medially; in the third session, we included the transitional zone, while in consecutive sessions, we increased the number of cores from all areas. Only 573 of the patients remained in follow-up. TRUS-biopsy detected prostate cancer (PCa) in 257 patients (44.85% overall detection rate). The detection rate in the first and second sessions was 32.98% and 14.94%, respectively, reaching 13.2% and 2.17%, in the third and fourth sessions, respectively. Prostate volumes were significantly smaller (52.9 +/- 22.4 cc vs 58.9 +/- 23.8 cc, P < 0.002) and the PSA/adenoma/prostate volumes ratio (ad-pro) ratio was higher (18.3 +/- 9 vs 13.96, P < 0/001) in the patients with PCa. Patients with PCa underwent fewer biopsy procedures and biopsy sessions than patients without a diagnosis of PCa (14.9 +/- 8.9 vs 20.4 +/- 12, P < 0.001;1.3 +/- 0.6 vs 1.7 +/- 0.9, P < 0.001). Biopsy samples obtained from the base were positive for cancer only in larger prostates with a mean volume of 54.3 +/- 15.3 cc. Numbers of biopsy procedures and PSA/ad-pro ratio were the strongest predictive factors for PCa detection (P < 0.001). In patients with a prostate volume >or=53 cc and PSA/ad-pro ratio >or=18, the optimal biopsy cores should be >or=15. Using this scheme, the discontinuation of biopsy procedures might be considered after three consecutive sessions.

  20. Parametric PET/MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies

    DTIC Science & Technology

    2014-10-01

    Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT The study investigates whether fusion PET/MRI imaging with 18F- choline PET/CT and...imaging with 18F- choline PET/CT and diffusion-weighted MRI can be successfully applied to target prostate cancer using image-guided prostate...Completed task. The 18F- choline synthesis was implemented and optimized for routine radiotracer production. RDRC committee approval as part of the IRB

  1. Magnetic Resonance Imaging Targeted Biopsy Improves Selection of Patients Considered for Active Surveillance for Clinically Low Risk Prostate Cancer Based on Systematic Biopsies.

    PubMed

    Ouzzane, Adil; Renard-Penna, Raphaele; Marliere, François; Mozer, Pierre; Olivier, Jonathan; Barkatz, Johann; Puech, Philippe; Villers, Arnauld

    2015-08-01

    Current selection criteria for active surveillance based on systematic biopsy underestimate prostate cancer volume and grade. We investigated the role of additional magnetic resonance imaging targeted biopsy in reclassifying patients eligible for active surveillance based on systematic biopsy. We performed a study at 2 institutions in a total of 281 men with increased prostate specific antigen. All men met certain criteria, including 1) prebiopsy magnetic resonance imaging, 12-core transrectal systematic biopsy and 2 additional magnetic resonance imaging targeted biopsies of lesions suspicious for cancer during the same sequence as systematic biopsy, and 2) eligibility for active surveillance based on systematic biopsy results. Criteria for active surveillance were prostate specific antigen less than 10 ng/ml, no Gleason grade 4/5, 5 mm or less involvement of any biopsy core and 2 or fewer positive systematic biopsy cores. Patient characteristics were compared between reclassified and nonreclassified groups based on magnetic resonance imaging targeted biopsy results. On magnetic resonance imaging 58% of the 281 patients had suspicious lesions. Magnetic resonance imaging targeted biopsy was positive for cancer in 81 of 163 patients (50%). Of 281 patients 28 (10%) were reclassified by magnetic resonance imaging targeted biopsy as ineligible for active surveillance based on Gleason score in 8, cancer length in 20 and Gleason score plus cancer length in 9. Suspicious areas on magnetic resonance imaging were in the anterior part of the prostate in 15 of the 28 men (54%). Reclassified patients had a smaller prostate volume (37 vs 52 cc) and were older (66.5 vs 63 years) than those who were not reclassified (p < 0.05). Magnetic resonance imaging targeted biopsy reclassified 10% of patients who were eligible for active surveillance based on systematic biopsy. Its incorporation into the active surveillance eligibility criteria may decrease the risk of reclassification to

  2. [Prostate biopsy under magnetic resonance imaging guidance].

    PubMed

    Kuplevatskiy, V I; CherkashiN, M A; Roshchin, D A; Berezina, N A; Vorob'ev, N A

    2016-01-01

    Prostate cancer (PC) is one of the most important problems in modern oncology. According to statistical data, PC ranks second in the cancer morbidity structure in the Russian Federation and developed countries and its prevalence has been progressively increasing over the past decade. A need for early diagnosis and maximally accurate morphological verification of the diagnosis in difficult clinical cases (inconvenient tumor location for standard transrectal biopsy; gland scarring changes concurrent with prostatitis and hemorrhage; threshold values of prostate-specific antigen with unclear changes in its doubling per unit time; suspicion of biochemical recurrence or clinical tumor progression after special treatment) leads to revised diagnostic algorithms and clinically introduced new high-tech invasive diagnostic methods. This paper gives the first analysis of literature data on Russian practice using one of the new methods to verify prostate cancer (transrectal prostate cancer under magnetic resonance imaging (MRI) guidance). The have sought the 1995-2015 data in the MEDLINE and Pubmed.

  3. Prospective validation of %p2PSA and the Prostate Health Index, in prostate cancer detection in initial prostate biopsies of Asian men, with total PSA 4-10 ng ml-1.

    PubMed

    Tan, Lincoln Gl; Tan, Yung Khan; Tai, Bee Choo; Tan, Karen Ml; Gauhar, Vineet; Tiong, Ho Yee; Hawkins, Robert Cw; Thamboo, Thomas P; Hong, Felicia Sk; Chiong, Edmund

    2017-01-01

    Despite its widespread use for prostate cancer screening, low specificity makes PSA a suboptimal biomarker, especially in the diagnostic "gray zone" of 4-10 ng ml-1 . False-positives lead to unnecessary biopsies with attendant morbidities. This is the first prospective validation study of %p2PSA and the Prostate Health Index (PHI) in Asian men presenting with a total PSA between 4.0 and 10 ng ml-1 . We studied 157 Asian men between 50 and 75 years old, with normal per rectal prostate examinations, undergoing their first prostate biopsy, using a standardized biopsy protocol, for PSA levels of 4-10 ng ml-1 . Thirty (19.1%) were found to have prostate cancer on biopsy. Statistically significant differences between patients with and without prostate cancer were found for total PSA, p2PSA, %p2PSA, and PHI. The areas under the curve of the receiver operating characteristic curve for total PSA, %fPSA, %p2PSA, and PHI were 0.479, 0.420, 0.695, and 0.794, respectively. PHI predicts prostatic biopsies results best. At a sensitivity of 90%, the specificity (95% CI) of PHI was 58.3%, more than triple the specificity of total PSA at 17.3%, potentially avoiding 77 (49%) unnecessary biopsies. Similar to studies in mainly Caucasian populations, we have prospectively shown that %p2PSA and PHI greatly outperform total and free to total PSA ratio, in the detection of prostate cancer at first biopsy. Higher PHI levels also correspond to increasing the risk of detecting GS ≥7 cancers. We have validated the use of PHI to aid decision-making regarding prostate biopsies in Asian men with serum PSA between 4 and 10 ng ml-1 .

  4. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    PubMed

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological

  5. Combination of Tramadol and Lidocaine for Pain Control During Transrectal Ultrasound-guided Prostate Biopsy: A Randomized Double-blinded Study.

    PubMed

    Sen, Haluk; Seckiner, Ilker; Bayrak, Omer; Sen, Elzem; Erturhan, Sakip; Yagci, Faruk

    2015-06-01

    To evaluate the efficacy of tramadol, lidocaine, and a combination of tramadol with lidocaine in pain relief using periprostatic nerve block technique by guidance of transrectal ultrasound (TRUS) before the prostate biopsy (PBx). For the indication of TRUS-PBx, the patients with a prostate-specific antigen (PSA) level >4.0 ng/mL or abnormal digital examination findings were selected. The patients were randomized through random method. Group 1: patients were administered 5 mL of 2% lidocaine; group 2: patients were administered 5 mL of 25-mg tramadol; and group 3: patients were administered 5 mL of 2% lidocaine + 25-mg tramadol. The procedures were completed in 10 minutes, and a visual pain scale was administered to the patients to question the pain severity. TRUS-guided PBx was performed in 60 patients with an age range of 57-77 years (mean age, 66.2 ± 7.49 years) and a PSA range of 1-1000 ng/mL. The mean PSA level of the groups was 28.5 (±7.5), 16.1 (±5.0), and 14.9 (±2.9) ng/mL, respectively. The postprocedural pain scores by visual pain scale were 4.6 ± 1.2, 5.4 ± 1.2, and 3.6 ± 0.9 in lidocaine, tramadol, and lidocaine + tramadol groups, respectively. Periprostatic nerve block is the current golden standard method owing to pain management and comfort provided, independent of the patient age and the number of core biopsies. We suggest that tramadol may also be used in this field to achieve better pain management by improving lidocaine's effect or as an alternative to lidocaine. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Feasibility and Diagnostic Yield of Endoscopic Ultrasonography-Guided Fine Needle Biopsy With a New Core Biopsy Needle Device in Patients With Gastric Subepithelial Tumors

    PubMed Central

    Lee, Minju; Min, Byung-Hoon; Lee, Hyuk; Ahn, Sangjeong; Lee, Jun Haeng; Rhee, Poong-Lyul; Kim, Jae J.; Sohn, Tae Sung; Kim, Sung; Kim, Kyoung-Mee

    2015-01-01

    Abstract As treatment decisions for patients with gastric subepithelial tumors (SETs) largely depend on the histopathologic diagnosis, noninvasive and effective tissue acquisition methods are definitely required for proper management of gastric SETs. Recently, a new endoscopic ultrasonography-guided fine needle biopsy (EUS-FNB) device with ProCore reverse bevel technology was developed. We aimed to elucidate the feasibility and diagnostic yield of EUS-FNB with this new core biopsy needle device in patients with gastric SETs. A prospectively maintained database was retrospectively reviewed to identify consecutive patients who underwent EUS-FNB with a 22-gauge ProCore needle for gastric SETs 2 cm or larger. The main outcome measurement was the diagnostic yield of EUS-FNB. Procedure results were categorized into diagnostic, suggestive, or nondiagnostic. Of the 43 patients, needle punctures were successful in all cases irrespective of tumor location. EUS-FNB procedure results were diagnostic in 86.0%, suggestive in 4.7%, and nondiagnostic in 9.3% of cases, respectively. The diagnostic yield was the highest in fundus (100.0%), followed by body (89.5%), cardia (83.3%), and antrum (50.0%). All 18 patients with cardiac SET were finally diagnosed to have leiomyoma, and 16 patients with diagnostic or suggestive results avoided surgery. A heterogeneous echo pattern on EUS was found in 33.3% of cases with nondiagnostic or suggestive results and in 5.4% with diagnostic results. In multivariate analysis, no independent predictor of unsuccessful EUS-FNB with nondiagnostic or suggestive results was identified. Agreement between EUS-FNB and surgical pathology was 100% with respect to the diagnosis of gastrointestinal stromal tumor. However, there was a significant discrepancy in mitotic counts observed between the EUS-FNB and surgical specimens in patients with gastrointestinal stromal tumor. There were no significant procedure-related adverse events during and after the

  7. For Single Dosing, Levofloxacin Is Superior to Ciprofloxacin When Combined With an Aminoglycoside in Preventing Severe Infections After Prostate Biopsy.

    PubMed

    Unnikrishnan, Raman; El-Shafei, Ahmed; Klein, Eric A; Jones, J Stephen; Kartha, Ganesh; Goldman, Howard B

    2015-06-01

    To investigate whether there is benefit with a longer acting oral fluoroquinolone, we compared the rate of infection after transrectal ultrasound-guided prostate biopsy between 2 prophylactic antibiotic regimens: ciprofloxacin vs levofloxacin, each combined with an aminoglycoside (AG). A retrospective review was performed of all transrectal ultrasound-guided prostate biopsies from September 2011 to January 2013. Initially our regimen entailed 1 dose of 500-mg ciprofloxacin and an AG. In June 2012, we switched to 1 dose of 750-mg levofloxacin and an AG. Infections were categorized as severe if requiring hospital admission, overnight observation, or emergency room treatment for fever or chills. Those treated as an outpatient were defined as mild. Of 1189 total biopsies, the total infection rate was 3.18% (17 of 535) in the ciprofloxacin group and 2.14% (14 of 654) in the levofloxacin group (P = .26). The rate of mild infection was 0.75% (4 of 535) in the ciprofloxacin group and 1.22% (8 of 654) in the levofloxacin group (P = .56). The rate of severe infection was significantly higher in the ciprofloxacin group at 2.43% (13 of 535) compared with that of 0.92% (6 of 654) in the levofloxacin group (P = .04). On multivariate analysis, use of ciprofloxacin rather than levofloxacin was associated with an increased risk of severe infection (odds ratio, 4.59; P = .04). Empiric prophylaxis for prostate biopsies with a single-dose fluoroquinolone augmented with an AG is optimal to reduce infectious complications. We found 750-mg levofloxacin resulted in significantly fewer severe infections compared with 500-mg ciprofloxacin potentially because of its longer half-life. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Molecular biomarkers to guide precision medicine in localized prostate cancer.

    PubMed

    Smits, Minke; Mehra, Niven; Sedelaar, Michiel; Gerritsen, Winald; Schalken, Jack A

    2017-08-01

    Major advances through tumor profiling technologies, that include next-generation sequencing, epigenetic, proteomic and transcriptomic methods, have been made in primary prostate cancer, providing novel biomarkers that may guide precision medicine in the near future. Areas covered: The authors provided an overview of novel molecular biomarkers in tissue, blood and urine that may be used as clinical tools to assess prognosis, improve selection criteria for active surveillance programs, and detect disease relapse early in localized prostate cancer. Expert commentary: Active surveillance (AS) in localized prostate cancer is an accepted strategy in patients with very low-risk prostate cancer. Many more patients may benefit from watchful waiting, and include patients of higher clinical stage and grade, however selection criteria have to be optimized and early recognition of transformation from localized to lethal disease has to be improved by addition of molecular biomarkers. The role of non-invasive biomarkers is challenging the need for repeat biopsies, commonly performed at 1 and 4 years in men under AS programs.

  9. Configuration and validation of a novel prostate disease nomogram predicting prostate biopsy outcome: A prospective study correlating clinical indicators among Filipino adult males with elevated PSA level.

    PubMed

    Chua, Michael E; Tanseco, Patrick P; Mendoza, Jonathan S; Castillo, Josefino C; Morales, Marcelino L; Luna, Saturnino L

    2015-04-01

    To configure and validate a novel prostate disease nomogram providing prostate biopsy outcome probabilities from a prospective study correlating clinical indicators and diagnostic parameters among Filipino adult male with elevated serum total prostate specific antigen (PSA) level. All men with an elevated serum total PSA underwent initial prostate biopsy at our institution from January 2011 to August 2014 were included. Clinical indicators, diagnostic parameters, which include PSA level and PSA-derivatives, were collected as predictive factors for biopsy outcome. Multiple logistic-regression analysis involving a backward elimination selection procedure was used to select independent predictors. A nomogram was developed to calculate the probability of the biopsy outcomes. External validation of the nomogram was performed using separate data set from another center for determination of sensitivity and specificity. A receiver-operating characteristic (ROC) curve was used to assess the accuracy in predicting differential biopsy outcome. Total of 552 patients was included. One hundred and ninety-one (34.6%) patients had benign prostatic hyperplasia, and 165 (29.9%) had chronic prostatitis. The remaining 196 (35.5%) patients had prostate adenocarcinoma. The significant independent variables used to predict biopsy outcome were age, family history of prostate cancer, prior antibiotic intake, PSA level, PSA-density, PSA-velocity, echogenic findings on ultrasound, and DRE status. The areas under the receiver-operating characteristic curve for prostate cancer using PSA alone and the nomogram were 0.688 and 0.804, respectively. The nomogram configured based on routinely available clinical parameters, provides high predictive accuracy with good performance characteristics in predicting the prostate biopsy outcome such as presence of prostate cancer, high Gleason prostate cancer, benign prostatic hyperplasia, and chronic prostatitis.

  10. Are 10-, 10-12-, or > 12-mm prostate biopsy core quality control cutoffs reasonable?

    PubMed

    Sanches, Brunno C F; Lalli, Ana Luiza; Azal Neto, Wilmar; Billis, Athanase; Reis, Leonardo Oliveira

    2018-07-01

    To explore the role of prostate biopsy core length on prediction of index tumor clinical significance and localization on radical prostatectomy (RP) and time to recurrence, hypothesizing 10-, 10-12-, or > 12-mm minimum core as potential biopsy quality control. Assessed 2424 prostate biopsy cores and corresponding RP of 202 patients submitted to the first set of 12 cores prostate biopsy between 2010 and 2015. Analyzed biopsy core length, age, prostate volume (PV), free and total PSA ratio, PSA density, RP index tumor clinical significance, extension, localization, surgical margins, and cancer control. Prostate biopsy confronted to surgical specimens defined Gleason grade-grouping system (1-5) agreement. Median age was 63.7 years, PSA 10.1 ng/dl, PSA density 28%, and mean follow-up 5 years. Recurrence was identified in 64 (31.7%) patients and predicted by PSA > 10 at time of diagnosis (p = 0.008), seminal vesicle invasion (p = 0.0019), core tumor percentage (p = 0.033), and tumor localization predominantly in the prostate base (p = 0017). The mean core length was longer in index tumor positive cores (p = 0.043) and in tumors classified as clinically insignificant (p = 0.011), without impact on tumor localization (basal vs apical p = 0.592; left vs. right p = 0.320). Biopsy core length categories (≤ 10, 10-12 and > 12 mm) did not significantly impact Gleason grade-grouping agreement or time to recurrence (p > 0.05). Core length was not significantly different in all Gleason grade-groupings 1-5 (p = 0.312). Prostate biopsy core length impacts tumor characterization; however, 10 mm minimum core length and even 10-12- and > 12-mm categories failed as a biopsy quality control in our data.

  11. Sex Steroid Metabolism in Benign and Malignant Intact Prostate Biopsies: Individual Profiling of Prostate Intracrinology

    PubMed Central

    Gianfrilli, Daniele; Pierotti, Silvia; Leonardo, Costantino; Ciccariello, Mauro

    2014-01-01

    In vitro studies reveal that androgens, oestrogens, and their metabolites play a crucial role in prostate homeostasis. Most of the studies evaluated intraprostatic hormone metabolism using cell lines or preprocessed specimens. Using an ex vivo model of intact tissue cultures with preserved architecture, we characterized the enzymatic profile of biopsies from patients with benign prostatic hyperplasia (BPH) or cancer (PC), focusing on 17β-hydroxy-steroid-dehydrogenases (17β-HSDs) and aromatase activities. Samples from 26 men who underwent prostate needle core biopsies (BPH n = 14; PC n = 12) were incubated with radiolabeled 3H-testosterone or 3H-androstenedione. Conversion was evaluated by TLC separation and beta-scanning of extracted supernatants. We identified three major patterns of conversion. The majority of BPHs revealed no active testosterone/oestradiol conversion as opposed to prostate cancer. Conversion correlated with histology and PSA, but not circulating hormones. Highest Gleason scores had a higher androstenedion-to-testosterone conversion and expression of 17β-HSD-isoenzymes-3/5. Conclusions. We developed an easy tool to profile individual intraprostatic enzymatic activity by characterizing conversion pathways in an intact tissue environment. In fresh biopsies we found that 17β-HSD-isoenzymes and aromatase activities correlate with biological behaviour allowing for morphofunctional phenotyping of pathology specimens and clinical monitoring of novel enzyme-targeting drugs. PMID:25184140

  12. Low grade urothelial carcinoma mimicking basal cell hyperplasia and transitional metaplasia in needle prostate biopsy.

    PubMed

    Arista-Nasr, Julian; Martinez-Benitez, Braulio; Bornstein-Quevedo, Leticia; Aguilar-Ayala, Elizmara; Aleman-Sanchez, Claudia Natalia; Ortiz-Bautista, Raul

    2016-01-01

    The vast majority of urothelial carcinomas infiltrating the bladder are consistente with high-grade tumors that can be easily recognized as malignant in needle prostatic biopsies. In contrast, the histological changes of low-grade urothelial carcinomas in this kind of biopsy have not been studied. We describe the clinicopathologic features of two patients with low-grade bladder carcinomas infiltrating the prostate. They reported dysuria and hematuria. Both had a slight elevation of the prostate specific antigen and induration of the prostatic lobes. Needle biopsies were performed. At endoscopy bladder tumors were found in both cases. Both biopsies showed nests of basophilic cells and cells with perinuclear clearing and slight atypia infiltrating acini and small prostatic ducts. The stroma exhibited extensive desmoplasia and chronic inflammation. The original diagnosis was basal cell hyperplasia and transitional metaplasia. The bladder tumors also showed low-grade urothelial carcinoma. In one case, the neoplasm infiltrated the lamina propria, and in another, the muscle layer. In both, a transurethral resection was performed for obstructive urinary symptoms. The neoplasms were positive for high molecular weight keratin (34BetaE12) and thrombomodulin. No metastases were found in either of the patients, and one of them has survived for five years. The diagnosis of low-grade urothelial carcinoma in prostate needle biopsies is difficult and may simulate benign prostate lesions including basal cell hyperplasia and urothelial metaplasia. It is crucial to recognize low-grade urothelial carcinoma in needle biopsies because only an early diagnosis and aggressive treatment can improve the prognosis for these patients.

  13. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    PubMed

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value<0

  14. A four-kallikrein panel for the prediction of repeat prostate biopsy: data from the European Randomized Study of Prostate Cancer screening in Rotterdam, Netherlands.

    PubMed

    Gupta, A; Roobol, M J; Savage, C J; Peltola, M; Pettersson, K; Scardino, P T; Vickers, A J; Schröder, F H; Lilja, H

    2010-08-24

    Most men with elevated levels of prostate-specific antigen (PSA) do not have prostate cancer, leading to a large number of unnecessary biopsies. A statistical model based on a panel of four kallikreins has been shown to predict the outcome of a first prostate biopsy. In this study, we apply the model to an independent data set of men with previous negative biopsy but persistently elevated PSA. The study cohort consisted of 925 men with a previous negative prostate biopsy and elevated PSA (>or=3 ng ml(-1)), with 110 prostate cancers detected (12%). A previously published statistical model was applied, with recalibration to reflect the lower positive biopsy rates on rebiopsy. The full-kallikrein panel had higher discriminative accuracy than PSA and DRE alone, with area under the curve (AUC) improving from 0.58 (95% confidence interval (CI): 0.52, 0.64) to 0.68 (95% CI: 0.62, 0.74), P<0.001, and high-grade cancer (Gleason >or=7) at biopsy with AUC improving from 0.76 (95% CI: 0.64, 0.89) to 0.87 (95% CI: 0.81, 0.94), P=0.003). Application of the panel to 1000 men with persistently elevated PSA after initial negative biopsy, at a 15% risk threshold would reduce the number of biopsies by 712; would miss (or delay) the diagnosis of 53 cancers, of which only 3 would be Gleason 7 and the rest Gleason 6 or less. Our data constitute an external validation of a previously published model. The four-kallikrein panel predicts the result of repeat prostate biopsy in men with elevated PSA while dramatically decreasing unnecessary biopsies.

  15. [Prostate cancer diagnostic by saturation randomized biopsy versus rigid targeted biopsy].

    PubMed

    Defontaines, J; Salomon, L; Champy, C; Cholley, I; Chiaradia, M; de la Taille, A

    2017-12-01

    Optimal diagram teaming up randomized biopsy (BR) to targeted biopsy (BC) is still missing for the diagnostic of prostate cancer (CP). This study compares diagram of 6, 12 or 18 BR with or without BC rigid. Between January 2014 and May 2016, 120 patients had prostate biopsy BR and BC. Each patient had 18 BR and BC. Results compared sextant (6 BR), standard (12 BR) and saturation (18 BR) protocol with or without the adding of BC for the detection of CP. Rectal examination was normal, mean PSA at 8.99ng/mL and mean volume at 54cm 3 . It was first round for 48% of patients. Forty-four cancers were found by the group 18 BR+BC (control). The detection rate was respectively, for 6, 12 and 18 BR of 61%, 82% and 91%. The add of BC increased this detection of +27% for 6 BR+BC, +13% for 12 BR+BC and +9% for 18 BR+BC. BC found 70% of all CP. Nine percent of CP were missed by BR only. Significant CP (Gleason≥7) diagnostic was the same for 12 BR+BC and 18 BR+BC. The add of BC to BR increase the detection of CP by 10%. Twelve BR+BC is the optimal diagram for the diagnostic of CP finding 95% of CP and 97% of significant CP. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. National Trends in Prostate Biopsy and Radical Prostatectomy Volumes Following the US Preventive Services Task Force Guidelines Against Prostate-Specific Antigen Screening.

    PubMed

    Halpern, Joshua A; Shoag, Jonathan E; Artis, Amanda S; Ballman, Karla V; Sedrakyan, Art; Hershman, Dawn L; Wright, Jason D; Shih, Ya Chen Tina; Hu, Jim C

    2017-02-01

    Studies demonstrate that use of prostate-specific antigen screening decreased significantly following the US Preventive Services Task Force (USPSTF) recommendation against prostate-specific antigen screening in 2012. To determine downstream effects on practice patterns in prostate cancer diagnosis and treatment following the 2012 USPSTF recommendation. Procedural volumes of certifying and recertifying urologists from 2009 through 2016 were evaluated for variation in prostate biopsy and radical prostatectomy (RP) volume. Trends were confirmed using the New York Statewide Planning and Research Cooperative System and Nationwide Inpatient Sample. The study included a representative sample of urologists across practice settings and nationally representative sample of all RP discharges. We obtained operative case logs from the American Board of Urology and identified urologists performing at least 1 prostate biopsy (n = 5173) or RP (n = 3748), respectively. The 2012 USPSTF recommendation against routine population-wide prostate-specific antigen screening. Change in median biopsy and RP volume per urologist and national procedural volume. Following the USPSTF recommendation, median biopsy volume per urologist decreased from 29 to 21 (interquartile range [IQR}, 12-34; P < .001). After adjusting for physician and practice characteristics, biopsy volume decreased by 28.7% following 2012 (parameter estimate, -0.25; SE, 0.03; P < .001). Similarly, following the USPSTF recommendation, median RP volume per urologist decreased from 7 (IQR, 3-15) to 6 (IQR, 2-12) (P < .001), and in adjusted analyses, RP volume decreased 16.2% (parameter estimate, -0.15; SE, 0.05; P = .003). Following the 2012 USPSTF recommendation, prostate biopsy and RP volumes decreased significantly. A panoramic vantage point is needed to evaluate the long-term consequences of the 2012 USPSTF recommendation.

  17. DNA Ploidy Measured on Archived Pretreatment Biopsy Material May Correlate With Prostate-Specific Antigen Recurrence After Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keyes, Mira, E-mail: mkeyes@bccancer.bc.ca; MacAulay, Calum; Hayes, Malcolm

    Purpose: To explore whether DNA ploidy of prostate cancer cells determined from archived transrectal ultrasound-guided biopsy specimens correlates with disease-free survival. Methods and Materials: Forty-seven failures and 47 controls were selected from 1006 consecutive low- and intermediate-risk patients treated with prostate {sup 125}I brachytherapy (July 1998-October 2003). Median follow-up was 7.5 years. Ten-year actuarial disease-free survival was 94.1%. Controls were matched using age, initial prostate-specific antigen level, clinical stage, Gleason score, use of hormone therapy, and follow-up (all P nonsignificant). Seventy-eight specimens were successfully processed; 27 control and 20 failure specimens contained more than 100 tumor cells were used formore » the final analysis. The Feulgen-Thionin stained cytology samples from archived paraffin blocks were used to determine the DNA ploidy of each tumor by measuring integrated optical densities. Results: The samples were divided into diploid and aneuploid tumors. Aneuploid tumors were found in 16 of 20 of the failures (80%) and 8 of 27 controls (30%). Diploid DNA patients had a significantly lower rate of disease recurrence (P=.0086) (hazard ratio [HR] 0.256). On multivariable analysis, patients with aneuploid tumors had a higher prostate-specific antigen failure rate (HR 5.13). Additionally, those with “excellent” dosimetry (V100 >90%; D90 >144 Gy) had a significantly lower recurrence rate (HR 0.25). All patients with aneuploid tumors and dosimetry classified as “nonexcellent” (V100 <90%; D90 <144 Gy) (5 of 5) had disease recurrence, compared with 40% of patients with aneuploid tumors and “excellent” dosimetry (8 of 15). In contrast, dosimetry did not affect the outcome for diploid patients. Conclusions: Using core biopsy material from archived paraffin blocks, DNA ploidy correctly classified the majority of failures and nonfailures in this study. The results suggest that DNA ploidy can be used

  18. Advancements in Magnetic Resonance–Guided Robotic Interventions in the Prostate

    PubMed Central

    Macura, Katarzyna J.; Stoianovici, Dan

    2011-01-01

    Magnetic resonance imaging (MRI) provides more detailed anatomical images of the prostate compared with the transrectal ultrasound imaging. Therefore, for the purpose of intervention in the prostate gland, diagnostic or therapeutic, MRI guidance offers a possibility of more precise targeting that may be crucial to the success of prostate interventions. However, access within the scanner is limited for manual instrument handling and the MR environment is most demanding among all imaging equipment with respect to the instrumentation used. A solution to this problem is the use of MR-compatible robots purposely designed to operate in the space and environmental restrictions inside the MR scanner allowing real-time interventions. Building an MRI-compatible robot is a very challenging engineering task because, in addition to the material restrictions that MRI instruments have, the robot requires actuators and sensors that limit the type of energies that can be used. Several important design problems have to be overcome before a successful MR-compatible robot application can be built. A number of MR-compatible robots, ranging from a simple manipulator to a fully automated system, have been developed, proposing ingenious solutions to the design challenge. Several systems have been already tested clinically for prostate biopsy and brachytherapy. As technology matures, precise image guidance for prostate interventions performed or assisted by specialized MR-compatible robotic devices may provide a uniquely accurate solution for guiding the intervention directly based on MR findings and feedback. Such an instrument would become a valuable clinical tool for biopsies directly targeting imaged tumor foci and delivering tumor-centered focal therapy. PMID:19512852

  19. Identification of proteomic biomarkers predicting prostate cancer aggressiveness and lethality despite biopsy-sampling error.

    PubMed

    Shipitsin, M; Small, C; Choudhury, S; Giladi, E; Friedlander, S; Nardone, J; Hussain, S; Hurley, A D; Ernst, C; Huang, Y E; Chang, H; Nifong, T P; Rimm, D L; Dunyak, J; Loda, M; Berman, D M; Blume-Jensen, P

    2014-09-09

    Key challenges of biopsy-based determination of prostate cancer aggressiveness include tumour heterogeneity, biopsy-sampling error, and variations in biopsy interpretation. The resulting uncertainty in risk assessment leads to significant overtreatment, with associated costs and morbidity. We developed a performance-based strategy to identify protein biomarkers predictive of prostate cancer aggressiveness and lethality regardless of biopsy-sampling variation. Prostatectomy samples from a large patient cohort with long follow-up were blindly assessed by expert pathologists who identified the tissue regions with the highest and lowest Gleason grade from each patient. To simulate biopsy-sampling error, a core from a high- and a low-Gleason area from each patient sample was used to generate a 'high' and a 'low' tumour microarray, respectively. Using a quantitative proteomics approach, we identified from 160 candidates 12 biomarkers that predicted prostate cancer aggressiveness (surgical Gleason and TNM stage) and lethal outcome robustly in both high- and low-Gleason areas. Conversely, a previously reported lethal outcome-predictive marker signature for prostatectomy tissue was unable to perform under circumstances of maximal sampling error. Our results have important implications for cancer biomarker discovery in general and development of a sampling error-resistant clinical biopsy test for prediction of prostate cancer aggressiveness.

  20. E. coli Multiresistant Meningitis after Transrectal Prostate Biopsy

    PubMed Central

    Alecsandru, Diana; Gestoso, Israel; Romero, Ana; Martinez, Alfonso; García, Ana; Lobo, Julio; Yagüe, M. Ruiz

    2006-01-01

    Escherichia coli meningitis is a frequent pathology in children younger than 3 years old, but is an uncommon disease in adults. E. coli infection is the main cause of intrahospital bacteremia as a consequence of the employment of different medical procedures. Our patient, male, 69 years old, presented with fever, progressive difficulty in breathing, and shivers 24 h after transrectal prostate biopsy, with an absence of any other symptoms. He received prophylactic treatment with ciprofloxacin and later empirical treatment with ampicillin and tobramicin. After that, the patient presented with fever, headache, behavioral changes, somnolence, disorientation, a fluctuating level of conscience, cutaneous widespread pallor, and acute urinary retention. On physical exploration, we observed generalized hypoventilation, Glasgow 10, stiffness of the neck, inconclusive Kernig; the remaining neurological exploration was normal. Systematic of blood: leukocytes = 8,510/mm3 (94.5% polymorphonuclear), platelet = 87,000/mm3, pH = 7.51, pCO2 = 28.8 mmHg, pO2 = 61 mmHg, O2 saturation = 93.8%, and remaining values were normal. Chest X- ray, cranial CT scan, urine cultures were normal. Blood culture: E. coli. CSF: glucose <0.4 g/l, total proteins = 3.05 g/l, PMN = 7 cells. Microscopic examination of the CSF: Gram-negative bacilli; CSF's culture: abundant E. coli. The case of acute meningitis by multiresistant E. coli after transrectal prostate biopsy presented demonstrates that antibiotic prevention with ciprofloxacin is not absolutely risk free. Besides the use of antibiotic prevention for multiresistant microorganisms, the urologist and other physicians involved in the procedure must not forget that the rate of major complications of transrectal prostate biopsy is 1%, especially when it is performed in patients who will not benefit from that biopsy. PMID:17619698

  1. [The Diagnostic Value of Pre-Biopsy Magnetic Resonance Imaging (MRI) for Detecting Prostate Cancer].

    PubMed

    Mori, Kohei; Miyoshi, Yasuhide; Yoneyama, Shuko; Ishida, Hiroaki; Hattori, Yusuke; Teranishi, Jun-ichi; Kondo, Keiichi; Noguchi, Kazumi

    2016-01-01

    We examined the value of pre-biopsy magnetic resonance imaging (MRI) for detecting prostate cancer. We analyzed 267 men with prostate-specific antigen (PSA) levels of 3-10 ng/ml who underwent systematic prostate needle biopsy. From April 2009 to March 2011, a total of 98 male patients underwent 16-core prostatic biopsies without pre-biopsy magnetic resonance imaging (MRI) (nonenforcement group). From April 2011 to March 2013, 169 men underwent pre-biopsy MRI [T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI)] (enforcement group). When MRI findings indicated cancer in the latter group, in addition to the systematic 16-core biopsy one or two targeted biopsies were performed. Patients without suspicious MRI findings underwent only systematic 16-core biopsy. Cancer detection rates in the nonenforcement and enforcement groups were 42.9% (48/92) and 46. 2% (78/169), respectively. The difference did not reach significance (p=0.612). Although the cancer detection rates were 39.4% (41/104) in the MRI-negative group and 56. 9% (37/65) in the MRI-positive group (p=0.039), the sensitivity and specificity for cancer detection by MRI were relatively low: 47.4% and 69.2%, respectively. By receiver-operating curve analysis, the area under the curve for cancer detection by MRI was only 0.583. There were two study limitations. First, the patient sample size was small. Second, it is unclear whether an adequate sample of the suspicious lesion was obtained by biopsy. We thus demonstrated that it might be improper to base a diagnosis solely on pre-biopsy MRI (T2WI and DWI) findings in men with serum PSA levels of 3-10 ng/ml.

  2. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  3. Intrarectal ice application prior to transrectal prostate biopsy: a prospective randomised trial accessing pain and collateral effects

    PubMed Central

    Çaliskan, Baris; Mutlu, Nazim

    2015-01-01

    Objectives To analyze the efficacy of intrarectal ice application as an anesthetic method prior to transrectal ultrasound (TRUS) guided prostate biopsy. Materials and Methods A total of 120 consecutive men were included into the study prospectively. Patients were equally randomized as group 1 and 2 with 60 patients each. Ice was applied as an anesthetic method 5 minutes before procedure to the patients in group 1. Patients in group 2 were applied 10 ml of 2% lidocaine gel 10 minutes before procedure. Twelve core biopsy procedure was performed for all patients. The pain level was evaluated using a visual analogue scale (VAS). Results Median pain score was 3.5 (1-8) in group 1 and 5 (1-8) in group 2. There is significantly difference between groups regarding the mean sense of pain level during the procedure. (p=0.007) There was also no difference in complications between two groups about presence and duration of macroscopic hematuria and rectal bleeding. Conclusions Intrarectal ice application prior to TRUS prostate biopsy has an effect on reducing pain. Development of new techniques about cold effect or ice can make this method more useful and decrease complication rates. PMID:25928515

  4. Risk score predicts high-grade prostate cancer in DNA-methylation positive, histopathologically negative biopsies.

    PubMed

    Van Neste, Leander; Partin, Alan W; Stewart, Grant D; Epstein, Jonathan I; Harrison, David J; Van Criekinge, Wim

    2016-09-01

    Prostate cancer (PCa) diagnosis is challenging because efforts for effective, timely treatment of men with significant cancer typically result in over-diagnosis and repeat biopsies. The presence or absence of epigenetic aberrations, more specifically DNA-methylation of GSTP1, RASSF1, and APC in histopathologically negative prostate core biopsies has resulted in an increased negative predictive value (NPV) of ∼90% and thus could lead to a reduction of unnecessary repeat biopsies. Here, it is investigated whether, in methylation-positive men, DNA-methylation intensities could help to identify those men harboring high-grade (Gleason score ≥7) PCa, resulting in an improved positive predictive value. Two cohorts, consisting of men with histopathologically negative index biopsies, followed by a positive or negative repeat biopsy, were combined. EpiScore, a methylation intensity algorithm was developed in methylation-positive men, using area under the curve of the receiver operating characteristic as metric for performance. Next, a risk score was developed combining EpiScore with traditional clinical risk factors to further improve the identification of high-grade (Gleason Score ≥7) cancer. Compared to other risk factors, detection of DNA-methylation in histopathologically negative biopsies was the most significant and important predictor of high-grade cancer, resulting in a NPV of 96%. In methylation-positive men, EpiScore was significantly higher for those with high-grade cancer detected upon repeat biopsy, compared to those with either no or low-grade cancer. The risk score resulted in further improvement of patient risk stratification and was a significantly better predictor compared to currently used metrics as PSA and the prostate cancer prevention trial (PCPT) risk calculator (RC). A decision curve analysis indicated strong clinical utility for the risk score as decision-making tool for repeat biopsy. Low DNA-methylation levels in PCa-negative biopsies led

  5. Prostate Enlargement: Benign Prostatic Hyperplasia (BPH)

    MedlinePlus

    ... such as ultrasound, a computerized tomography scan, or magnetic resonance imaging to guide the biopsy needle into ... heats and destroys selected portions of prostate tissue. Shields protect the urethra from heat damage. Transurethral microwave ...

  6. Statin Use, Serum Lipids, and Prostate Inflammation in Men with a Negative Prostate Biopsy: Results from the REDUCE Trial.

    PubMed

    Allott, Emma H; Howard, Lauren E; Vidal, Adriana C; Moreira, Daniel M; Castro-Santamaria, Ramiro; Andriole, Gerald L; Freedland, Stephen J

    2017-06-01

    Statin use is associated with lower advanced prostate cancer risk. In addition to cholesterol lowering, statins have systemic anti-inflammatory properties. However, their effect on histologic prostate inflammation is not well understood, particularly among men at increased prostate cancer risk but with a negative prostate biopsy. We examined associations between serum lipid levels, statin use, and histologic prostate inflammation using data from 6,655 men with a negative baseline prostate biopsy in the REduction by DUtasteride of prostate Cancer Events (REDUCE) trial. Statin use and lipid levels [total cholesterol, low-density lipoprotein (LDL), high-density lipoprotein (HDL), triglycerides] were assessed at baseline. Inflammation was assessed by central review. Logistic regression was used to examine the effects of lipids and statin use on presence and extent of chronic and acute prostate inflammation [none, moderate (<20%), severe (≥20% biopsy cores)]. Chronic and acute inflammation affected 77% and 15% of men, respectively. Men with high HDL (≥60 vs. <40 mg/dL) had reduced presence of acute inflammation [OR, 0.79; 95% confidence interval (CI), 0.63-0.99] and were less likely to have severe acute inflammation (OR, 0.66; 95% CI, 0.45-0.97), but there were no other associations between lipids and inflammation. Statin users had reduced presence of chronic inflammation (OR, 0.81; 95% CI, 0.69-0.95) and were less likely to have severe chronic (OR, 0.80; 95% CI, 0.68-0.95) and severe acute inflammation (OR, 0.73; 95% CI, 0.53-1.00), relative to non-users. Given the possible role for inflammation in prostate cancer, the inverse association between statins and prostate inflammation suggests a mechanism linking statins with lower advanced prostate cancer risk. Cancer Prev Res; 10(6); 319-26. ©2017 AACR . ©2017 American Association for Cancer Research.

  7. Incidental Finding of Cryptococcus on Prostate Biopsy for Prostate Adenocarcinoma Following Cardiac Transplant: Case Report and Review of the Literature.

    PubMed

    Shah, Sujal I; Bui, Hai; Velasco, Nelson; Rungta, Shilpa

    2017-11-06

    BACKGROUND Cryptococcus is the third most common invasive fungal organism in immunocompromised patients, including transplant patients, and usually involves the central nervous system and lungs, with a median time to infection of 25 months. We report a case of Cryptococcus of the prostate gland, found as an incidental finding on prostate biopsy for prostate adenocarcinoma, four months following cardiac transplantation. CASE REPORT A 62-year-old male African-American who had a cardiac transplant four months previously, underwent a six-core prostate biopsy for a two-year history of increasing prostate-specific antigen (PSA) levels, and a recent history of non-specific urinary tract symptoms. A prostatic adenocarcinoma, Gleason grade 4+4=8, was diagnosed on histopathology, and 'foamy' cells were seen in the biopsies. Histochemical stains, including Grocott methenamine silver (GMS), and periodic acid-Schiff (PAS) showed abundant round and oval 5-7 µm diameter fungal elements; mucicarmine highlighted the fungal polysaccharide capsule, diagnostic for Cryptococcus. Cryptococcal antigen detection was made by the latex agglutination test and cultures. We reviewed the literature and found 70 published cases (from 1946-2008) of Cryptococcus of the prostate gland, with only one previous case presenting five years following cardiac transplantation. CONCLUSIONS Fungal infections of the prostate are rare, and occur mainly in immunocompromised patients. We present a unique case of prostatic Cryptococcus found incidentally at four months following cardiac transplantation. This case report highlights the need to consider atypical fungal infection as a differential diagnosis for prostatitis in immunosuppressed patients, including transplant patients.

  8. A panel of kallikrein markers can reduce unnecessary biopsy for prostate cancer: data from the European Randomized Study of Prostate Cancer Screening in Göteborg, Sweden

    PubMed Central

    Vickers, Andrew J; Cronin, Angel M; Aus, Gunnar; Pihl, Carl-Gustav; Becker, Charlotte; Pettersson, Kim; Scardino, Peter T; Hugosson, Jonas; Lilja, Hans

    2008-01-01

    Background Prostate-specific antigen (PSA) is widely used to detect prostate cancer. The low positive predictive value of elevated PSA results in large numbers of unnecessary prostate biopsies. We set out to determine whether a multivariable model including four kallikrein forms (total, free, and intact PSA, and human kallikrein 2 (hK2)) could predict prostate biopsy outcome in previously unscreened men with elevated total PSA. Methods The study cohort comprised 740 men in Göteborg, Sweden, undergoing biopsy during the first round of the European Randomized study of Screening for Prostate Cancer. We calculated the area-under-the-curve (AUC) for predicting prostate cancer at biopsy. AUCs for a model including age and PSA (the 'laboratory' model) and age, PSA and digital rectal exam (the 'clinical' model) were compared with those for models that also included additional kallikreins. Results Addition of free and intact PSA and hK2 improved AUC from 0.68 to 0.83 and from 0.72 to 0.84, for the laboratory and clinical models respectively. Using a 20% risk of prostate cancer as the threshold for biopsy would have reduced the number of biopsies by 424 (57%) and missed only 31 out of 152 low-grade and 3 out of 40 high-grade cancers. Conclusion Multiple kallikrein forms measured in blood can predict the result of biopsy in previously unscreened men with elevated PSA. A multivariable model can determine which men should be advised to undergo biopsy and which might be advised to continue screening, but defer biopsy until there was stronger evidence of malignancy. PMID:18611265

  9. Follow-up of negative MRI-targeted prostate biopsies: when are we missing cancer?

    PubMed

    Gold, Samuel A; Hale, Graham R; Bloom, Jonathan B; Smith, Clayton P; Rayn, Kareem N; Valera, Vladimir; Wood, Bradford J; Choyke, Peter L; Turkbey, Baris; Pinto, Peter A

    2018-05-21

    Multiparametric magnetic resonance imaging (mpMRI) has improved clinicians' ability to detect clinically significant prostate cancer (csPCa). Combining or fusing these images with the real-time imaging of transrectal ultrasound (TRUS) allows urologists to better sample lesions with a targeted biopsy (Tbx) leading to the detection of greater rates of csPCa and decreased rates of low-risk PCa. In this review, we evaluate the technical aspects of the mpMRI-guided Tbx procedure to identify possible sources of error and provide clinical context to a negative Tbx. A literature search was conducted of possible reasons for false-negative TBx. This includes discussion on false-positive mpMRI findings, termed "PCa mimics," that may incorrectly suggest high likelihood of csPCa as well as errors during Tbx resulting in inexact image fusion or biopsy needle placement. Despite the strong negative predictive value associated with Tbx, concerns of missed disease often remain, especially with MR-visible lesions. This raises questions about what to do next after a negative Tbx result. Potential sources of error can arise from each step in the targeted biopsy process ranging from "PCa mimics" or technical errors during mpMRI acquisition to failure to properly register MRI and TRUS images on a fusion biopsy platform to technical or anatomic limits on needle placement accuracy. A better understanding of these potential pitfalls in the mpMRI-guided Tbx procedure will aid interpretation of a negative Tbx, identify areas for improving technical proficiency, and improve both physician understanding of negative Tbx and patient-management options.

  10. Phase I/II prospective trial of cancer-specific imaging using ultrasound spectrum analysis tissue-type imaging to guide dose-painting prostate brachytherapy.

    PubMed

    Ennis, Ronald D; Quinn, S Aidan; Trichter, Frieda; Ryemon, Shannon; Jain, Anudh; Saigal, Kunal; Chandrashekhar, Sarayu; Romas, Nicholas A; Feleppa, Ernest J

    2015-01-01

    To assess the technical feasibility, toxicity, dosimetry, and preliminary efficacy of dose-painting brachytherapy guided by ultrasound spectrum analysis tissue-type imaging (TTI) in low-risk, localized prostate cancer. Fourteen men with prostate cancer who were candidates for brachytherapy as sole treatment were prospectively enrolled. Treatment planning goal was to escalate the tumor dose to 200% with a modest de-escalation of dose to remaining prostate compared with our standard. Primary end points included technical feasibility of TTI-guided brachytherapy and equivalent or better toxicity compared with standard brachytherapy. Secondary end points included dose escalation to tumor regions and de-escalated dose to nontumor regions on the preimplant plan, negative prostate biopsy at 2 years, and freedom from biochemical failure. Thirteen of fourteen men successfully completed the TTI-guided brachytherapy procedure for a feasibility rate of 93%. A software malfunction resulted in switching one patient from TTI-guided to standard brachytherapy. An average of 2.7 foci per patient was demonstrated and treated with an escalated dose. Dosimetric goals on preplan were achieved. One patient expired from unrelated causes 65 days after brachytherapy. Toxicity was at least as low as standard brachytherapy. Two-year prostate biopsies were obtained from six men; five (83%) were definitively negative, one showed evidence of disease with treatment effect, and none were positive. No patients experienced biochemical recurrence after a median followup of 31.5 (24-52) months. We have demonstrated that TTI-guided dose-painting prostate brachytherapy is technically feasible and results in clinical outcomes that are encouraging in terms of low toxicity and successful biochemical disease control. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  11. Accuracy of the prostate health index versus the urinary prostate cancer antigen 3 score to predict overall and significant prostate cancer at initial biopsy.

    PubMed

    Seisen, Thomas; Rouprêt, Morgan; Brault, Didier; Léon, Priscilla; Cancel-Tassin, Géraldine; Compérat, Eva; Renard-Penna, Raphaële; Mozer, Pierre; Guechot, Jérome; Cussenot, Olivier

    2015-01-01

    It remains unclear whether the Prostate Health Index (PHI) or the urinary Prostate-Cancer Antigen 3 (PCA-3) score is more accurate at screening for prostate cancer (PCa). The aim of this study was to prospectively compare the accuracy of PHI and PCA-3 scores to predict overall and significant PCa in men undergoing an initial prostate biopsy. Double-blind assessments of PHI and PCA-3 were conducted by referent physicians in 138 patients who subsequently underwent trans-rectal ultrasound-guided prostate biopsy according to a 12-core scheme. Predictive accuracies of PHI and PCA-3 were assessed using AUC and compared according to the DeLong method. Diagnostic performances with usual cut-off values for positivity (i.e., PHI >40 and PCA-3 >35) were calculated, and odds ratios associated with predicting PCa overall and significant PCa as defined by pathological updated Epstein criteria (i.e., Gleason score ≥7, more than three positive cores, or >50% cancer involvement in any core) were estimated using logistic regression. Prevalences of overall and significant PCa were 44.9% and 28.3%, respectively. PCA-3 (AUC = 0.71) was the most accurate predictor of PCa overall, and significantly outperformed PHI (AUC = 0.65; P = 0.03). However, PHI (AUC = 0.80) remained the most accurate predictor when screening exclusively for significant PCa and significantly outperformed PCA-3 (AUC = 0.55; P = 0.03). Furthermore, PCA-3 >35 had the best accuracy, and positive or negative predictive values when screening for PCa overall whereas these diagnostic performances were greater for PHI >40 when exclusively screening for significant PCa. PHI > 40 combined with PCA-3 > 35 was more specific in both cases. In multivariate analyses, PCA-3 >35 (OR = 5.68; 95%CI = [2.21-14.59]; P < 0.001) was significantly correlated with the presence of PCa overall, but PHI >40 (OR = 9.60; 95%CI = [1.72-91.32]; P = 0.001) was the only independent predictor

  12. Current beliefs and practice patterns among urologists regarding prostate magnetic resonance imaging and magnetic resonance-targeted biopsy.

    PubMed

    Muthigi, Akhil; Sidana, Abhinav; George, Arvin K; Kongnyuy, Michael; Maruf, Mahir; Valayil, Subin; Wood, Bradford J; Pinto, Peter A

    2017-01-01

    Multiparametric magnetic resonance imaging (MRI) and magnetic resonance (MR) -targeted biopsy have a growing role in the screening and evaluation of prostate cancer. We aim to evaluate the current knowledge, attitude, and practice patterns of urologists regarding this new technique. An anonymous online questionnaire was designed to collect information on urologists' beliefs and use of prostate multiparametric MRI and MR-targeted biopsy. The survey was sent to members of the Society of Urologic Oncology, the Endourological Society, and European Association of Urology. Multivariate logistic regression analysis was performed to determine predictors for use of prostate MRI and MR-targeted biopsy. A total of 302 responses were received (Endourological Society: 175, European Association of Urology: 23, and Society of Urologic Oncology: 104). Most respondents (83.6%) believe MR-targeted biopsy to be moderately to extremely beneficial in the evaluation of prostate cancer. Overall, 85.7% of responders use prostate MRI in their practice, and 63.0% use MR-targeted biopsy. The 2 most common settings for use of MR-targeted biopsy include patients with history of prior negative biopsy result (96.3%) and monitoring patients on active surveillance (72.5%). In those who do not use MR-targeted biopsy, the principal reasons were lack of necessary infrastructure (64.1%) and prohibitive costs (48.1%). On multivariate logistic regression analysis, practice in an academic setting (1.86 [1.02-3.40], P = 0.043) and performing greater than 25 radical prostatectomies per year (2.32 [1.18-4.56], P = 0.015) remained independent predictors for using MR-targeted biopsy. Most respondents of our survey look favorably on use of prostate MRI and MR-targeted biopsy in clinical practice. Over time, reduction in fixed costs and easier access to equipment may lead to further dissemination of this novel and potentially transformative technology. Published by Elsevier Inc.

  13. The role of blood neutrophil count and the neutrophil-to-lymphocyte ratio as a predictive factor for prostate biopsy results.

    PubMed

    Kamali, Koosha; Ashrafi, Mojtaba; Shadpour, Pejman; Ameli, Mojtaba; Khayyamfar, Amirmahdi; Abolhasani, Maryam; Azizpoor, Amin

    2018-04-01

    It is apparent that prostate cancer has harmful effects on the erythrocytes, leucocytes, and platelets. In addition, it has been suggested that the toxic granules in neutrophils lead to inflammation in the cancerous tissues besides the activation of monocytes, so in this study we aimed to evaluate the blood neutrophil count besides the neutrophil-to-lymphocyte ratio as a predictive factor for prostate biopsy results and their relationship with prostate cancer grade in patients undergoing biopsy of the prostate. For all men with irritative lower urinary tract symptoms visiting Hasheminezhad Hospital from January to July 2015, in case of having a suspicious digital rectal examination or aged above 40 years, prostate-specific antigen was requested and in case of abnormal results, they underwent prostate biopsy. In order to examine the study hypothesis, the blood neutrophil count and the neutrophil-to-lymphocyte ratio were measured and compared with the abnormal prostate-specific antigen results and suspicious digital rectal examination. Among the 500 referred samples for biopsy, 352 (70.4%) had a negative biopsy result, while it was positive in the other 148 (29.6). The mean neutrophil count showed no statistical difference regarding the biopsy results (p = 0.381). When measuring the neutrophil-to-lymphocyte ratio again with biopsy results, no statistically significant difference was obtained based on the biopsy results (p = 0.112). Neutrophil count and neutrophil-to-lymphocyte ratio cannot be predictive factors for positive prostate cancer biopsy.

  14. Comparison of Digital Rectal Examination and Serum Prostate Specific Antigen in the Early Detection of Prostate Cancer: Results of a Multicenter Clinical Trial of 6,630 Men.

    PubMed

    Catalona, William J; Richie, Jerome P; Ahmann, Frederick R; Hudson, M'Liss A; Scardino, Peter T; Flanigan, Robert C; DeKernion, Jean B; Ratliff, Timothy L; Kavoussi, Louis R; Dalkin, Bruce L; Waters, W Bedford; MacFarlane, Michael T; Southwick, Paula C

    2017-02-01

    To compare the efficacy of digital rectal examination and serum prostate specific antigen (PSA) in the early detection of prostate cancer, we conducted a prospective clinical trial at 6 university centers of 6,630 male volunteers 50 years old or older who underwent PSA determination (Hybritech Tandom-E or Tandem-R assays) and digital rectal examination. Quadrant biopsies were performed if the PSA level was greater than 4 μg./l. or digital rectal examination was suspicious, even if transrectal ultrasonography revealed no areas suspicious for cancer. The results showed that 15% of the men had a PSA level of greater than 4 μg./l., 15% had a suspicious digital rectal examination and 26% had suspicious findings on either or both tests. Of 1,167 biopsies performed cancer was detected in 264. PSA detected significantly more tumors (82%, 216 of 264 cancers) than digital rectal examination (55%, 146 of 264, p = 0.001). The cancer detection rate was 3.2% for digital rectal examination, 4.6% for PSA and 5.8% for the 2 methods combined. Positive predictive value was 32% for PSA and 21% for digital rectal examination. Of 160 patients who underwent radical prostatectomy and pathological staging 114 (71%) had organ confined cancer: PSA detected 85 (75%) and digital rectal examination detected 64 (56%, p = 0.003). Use of the 2 methods in combination increased detection of organ confined disease by 78% (50 of 64 cases) over digital rectal examination alone. If the performance of a biopsy would have required suspicious transrectal ultrasonography findings, nearly 40% of the tumors would have been missed. We conclude that the use of PSA in conjunction with digital rectal examination enhances early prostate cancer detection. Prostatic biopsy should be considered if either the PSA level is greater than 4 μg./l. or digital rectal examination is suspicious for cancer, even in the absence of abnormal transrectal ultrasonography findings. Copyright © 1994 American Urological

  15. Infiltration of tumour-associated macrophages in prostate biopsy specimens is predictive of disease progression after hormonal therapy for prostate cancer.

    PubMed

    Nonomura, Norio; Takayama, Hitoshi; Nakayama, Masashi; Nakai, Yasutomo; Kawashima, Atsunari; Mukai, Masatoshi; Nagahara, Akira; Aozasa, Katsuyuki; Tsujimura, Akira

    2011-06-01

    • To evaluate tumour-associated macrophage (TAM) infiltration in prostate biopsy specimens as a possible prognostic factor for prostate cancer (PCa) after hormonal therapy. • Immunostaining of TAMs in prostate biopsy specimens was performed using a monoclonal antibody CD68 for 71 patients having PCa treated with hormonal therapy. • Six microscopic (×400) fields around the cancer foci were selected for TAM counting. • The median value of serum prostate-specific antigen (PSA) was 50.1 ng/mL, and the median TAM count was 22. • Recurrence-free survival was significantly better in patients with fewer TAMs (<22) than in those with higher numbers of TAMs (≥22) (P < 0.001). • TAM count was higher in those with higher serum PSA (PSA), higher Gleason score, clinical T stage or those with PSA failure. Cox multivariate analysis showed that TAM count is one of the prognostic factors for PCa treated by hormonal therapy (P < 0.0001). • TAM infiltration in prostate needle biopsy specimens is a useful predictive factor for PSA failure or progression of PCa after hormonal therapy. © 2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.

  16. Prostate cancer-associated gene expression alterations determined from needle biopsies.

    PubMed

    Qian, David Z; Huang, Chung-Ying; O'Brien, Catherine A; Coleman, Ilsa M; Garzotto, Mark; True, Lawrence D; Higano, Celestia S; Vessella, Robert; Lange, Paul H; Nelson, Peter S; Beer, Tomasz M

    2009-05-01

    To accurately identify gene expression alterations that differentiate neoplastic from normal prostate epithelium using an approach that avoids contamination by unwanted cellular components and is not compromised by acute gene expression changes associated with tumor devascularization and resulting ischemia. Approximately 3,000 neoplastic and benign prostate epithelial cells were isolated using laser capture microdissection from snap-frozen prostate biopsy specimens provided by 31 patients who subsequently participated in a clinical trial of preoperative chemotherapy. cDNA synthesized from amplified total RNA was hybridized to custom-made microarrays composed of 6,200 clones derived from the Prostate Expression Database. Expression differences for selected genes were verified using quantitative reverse transcription-PCR. Comparative analyses identified 954 transcript alterations associated with cancer (q < 0.01%), including 149 differentially expressed genes with no known functional roles. Gene expression changes associated with ischemia and surgical removal of the prostate gland were absent. Genes up-regulated in prostate cancer were statistically enriched in categories related to cellular metabolism, energy use, signal transduction, and molecular transport. Genes down-regulated in prostate cancers were enriched in categories related to immune response, cellular responses to pathogens, and apoptosis. A heterogeneous pattern of androgen receptor expression changes was noted. In exploratory analyses, androgen receptor down-regulation was associated with a lower probability of cancer relapse after neoadjuvant chemotherapy followed by radical prostatectomy. Assessments of tumor phenotypes based on gene expression for treatment stratification and drug targeting of oncogenic alterations may best be ascertained using biopsy-based analyses where the effects of ischemia do not complicate interpretation.

  17. Prostate Cancer-Associated Gene Expression Alterations Determined from Needle Biopsies

    PubMed Central

    Qian, David Z.; Huang, Chung-Ying; O'Brien, Catherine A.; Coleman, Ilsa M.; Garzotto, Mark; True, Lawrence D.; Higano, Celestia S.; Vessella, Robert; Lange, Paul H.; Nelson, Peter S.; Beer, Tomasz M.

    2010-01-01

    Purpose To accurately identify gene expression alterations that differentiate neoplastic from normal prostate epithelium using an approach that avoids contamination by unwanted cellular components and is not compromised by acute gene expression changes associated with tumor devascularization and resulting ischemia. Experimental Design Approximately 3,000 neoplastic and benign prostate epithelial cells were isolated using laser capture microdissection from snap-frozen prostate biopsy specimens provided by 31 patients who subsequently participated in a clinical trial of preoperative chemotherapy. cDNA synthesized from amplified total RNA was hybridized to custom-made microarrays comprised of 6200 clones derived from the Prostate Expression Database. Expression differences for selected genes were verified using quantitative RT-PCR. Results Comparative analyses identified 954 transcript alterations associated with cancer (q value <0.01%) including 149 differentially expressed genes with no known functional roles. Gene expression changes associated with ischemia and surgical removal of the prostate gland were absent. Genes up-regulated in prostate cancer were statistically enriched in categories related to cellular metabolism, energy utilization, signal transduction, and molecular transport. Genes down-regulated in prostate cancers were enriched in categories related to immune response, cellular responses to pathogens, and apoptosis. A heterogeneous pattern of AR expression changes was noted. In exploratory analyses, AR down regulation was associated with a lower probability of cancer relapse after neoadjuvant chemotherapy followed by radical prostatectomy. Conclusions Assessments of tumor phenotypes based on gene expression for treatment stratification and drug targeting of oncogenic alterations may best be ascertained using biopsy-based analyses where the effects of ischemia do not complicate interpretation. PMID:19366833

  18. Diffuse reflectance imaging: a tool for guided biopsy

    NASA Astrophysics Data System (ADS)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  19. Age and total and free prostate-specific antigen levels for predicting prostate volume in patients with benign prostatic hyperplasia.

    PubMed

    Coban, Soner; Doluoglu, Omer Gokhan; Keles, Ibrahim; Demirci, Hakan; Turkoglu, Ali Riza; Guzelsoy, Muhammet; Karalar, Mustafa; Demirbas, Murat

    2016-06-01

    To investigate the predictive values of free prostate-specific antigen (fPSA), total PSA (tPSA) and age on the prostate volume. The data of 2148 patients with lower urinary tract symptoms were analyzed retrospectively. The patients who had transrectal ultrasonography guided 10 core biopsies owing to the findings obtained on digital rectal examination and presence of high PSA levels (PSA = 2.5-10 ng/dl), and proven to have BPH histopathologically were included in the study. Age, tPSA, fPSA and the prostate volumes (PV) of the patients were noted. One thousand patients that fulfilled the inclusion criteria were included in the study. The PV of the patients were significantly correlated with age, tPSA and fPSA (p < 0.001 and r = 0.307, p < 0.001 and r = 0.382, p < 0.001 and r = 0.296, respectively). On linear regression model, fPSA was found as a stronger predictive for PV (AUC = 0.75, p < 0.001) when compared to age (AUC = 0.64, p < 0.001), and tPSA (AUC = 0.69, p = 0.013). Although tPSA is an important prognostic factor for predicting PV, the predictive value of fPSA is higher. PV can easily be predicted by using age, and serum tPSA and fPSA levels.

  20. Escherichia coli isolates from patients with bacteremic urinary tract infection are genetically distinct from those derived from sepsis following prostate transrectal biopsy.

    PubMed

    Dan, Michael; Yair, Yael; Samosav, Alex; Gottesman, Tamar; Yossepowitch, Orit; Harari-Schwartz, Orna; Tsivian, Alexander; Schreiber, Rachel; Gophna, Uri

    2015-01-01

    Transrectal ultrasound-guided (TRUS) prostate biopsy is a very common procedure that is generally considered relatively safe. However, severe sepsis can occur after TRUS prostate biopsies, with Escherichia coli being the predominant causative agent. A common perception is that the bacteria that cause post-TRUS prostate biopsy infections originate in the urinary tract, but this view has not been adequately tested. Yet other authors believe on the basis of indirect evidence that the pathogens are introduced into the bloodstream by the biopsy needle after passage through the rectal mucosa. We compared E. coli isolates from male patients with bacteremic urinary tract infection (B-UTI) to isolates of patients with post prostate biopsy sepsis (PPBS), in terms of their sequence types, determined by multi-locus sequence typing (MLST) and their virulence markers. B-UTI isolates were much richer in virulence genes than were PPBS isolates, supporting the hypothesis that E. coli causing PPBS derive directly from the rectum. Sequence type 131 (ST131) strains and related strain from the ST131 were common (>30%) among the E. coli isolates from PPBS patients as well as from B-UTI patients and all these strains expressed extended spectrum beta-lactamases. Our finding supports the hypothesis that E. coli causing PPBS derive directly from the rectum, bypassing the urinary tract, and therefore do not require many of the virulence capabilities necessary for an E. coli strain that must persist in the urinary tract. In light of the increasing prevalence of highly resistant E. coli strains, a new approach for prevention of PPBS is urgently required. Copyright © 2015. Published by Elsevier GmbH.

  1. Frequency of Propionibacterium acnes Infection in Prostate Glands with Negative Biopsy Results Is an Independent Risk Factor for Prostate Cancer in Patients with Increased Serum PSA Titers

    PubMed Central

    Ito, Takashi; Uchida, Keisuke; Sekine, Masaki; Nakajima, Yutaka; Furukawa, Asuka; Suzuki, Yoshimi; Kumagai, Jiro; Akashi, Takumi

    2017-01-01

    Background Propionibacterium acnes has recently been implicated as a cause of chronic prostatitis and this commensal bacterium may be linked to prostate carcinogenesis. The occurrence of intracellular P. acnes infection in prostate glands and the higher frequency of P. acnes-positive glands in radical prostatectomy specimens from patients with prostate cancer (PCa) than in those from patients without PCa led us to examine whether the P. acnes-positive gland frequency can be used to assess the risk for PCa in patients whose first prostate biopsy, performed due to an increased prostate-specific antigen (PSA) titer, was negative. Methods We retrospectively collected the first and last prostate biopsy samples from 44 patients that were diagnosed PCa within 4 years after the first negative biopsy and from 36 control patients with no PCa found in repeated biopsy for at least 3 years after the first biopsy. We evaluated P. acnes-positive gland frequency and P. acnes-positive macrophage number using enzyme-immunohistochemistry with a P. acnes-specific monoclonal antibody (PAL antibody). Results The frequency of P. acnes-positive glands was higher in PCa samples than in control samples in both first biopsy samples and in combined first and last biopsy samples (P < 0.001). A frequency greater than the threshold (18.5 and 17.7, respectively) obtained by each receiver operating characteristic curve was an independent risk factor for PCa (P = 0.003 and 0.001, respectively) with odds ratios (14.8 and 13.9, respectively) higher than those of serum PSA titers of patients just before each biopsy (4.6 and 2.3, respectively). The number of P. acnes-positive macrophages did not differ significantly between PCa and control samples. Conclusions These results suggested that the frequency of P. acnes-positive glands in the first negative prostate biopsy performed due to increased PSA titers can be supportive information for urologists in planning repeated biopsy or follow-up strategies

  2. Frequency of Propionibacterium acnes Infection in Prostate Glands with Negative Biopsy Results Is an Independent Risk Factor for Prostate Cancer in Patients with Increased Serum PSA Titers.

    PubMed

    Kakegawa, Tomoya; Bae, Yuan; Ito, Takashi; Uchida, Keisuke; Sekine, Masaki; Nakajima, Yutaka; Furukawa, Asuka; Suzuki, Yoshimi; Kumagai, Jiro; Akashi, Takumi; Eishi, Yoshinobu

    2017-01-01

    Propionibacterium acnes has recently been implicated as a cause of chronic prostatitis and this commensal bacterium may be linked to prostate carcinogenesis. The occurrence of intracellular P. acnes infection in prostate glands and the higher frequency of P. acnes-positive glands in radical prostatectomy specimens from patients with prostate cancer (PCa) than in those from patients without PCa led us to examine whether the P. acnes-positive gland frequency can be used to assess the risk for PCa in patients whose first prostate biopsy, performed due to an increased prostate-specific antigen (PSA) titer, was negative. We retrospectively collected the first and last prostate biopsy samples from 44 patients that were diagnosed PCa within 4 years after the first negative biopsy and from 36 control patients with no PCa found in repeated biopsy for at least 3 years after the first biopsy. We evaluated P. acnes-positive gland frequency and P. acnes-positive macrophage number using enzyme-immunohistochemistry with a P. acnes-specific monoclonal antibody (PAL antibody). The frequency of P. acnes-positive glands was higher in PCa samples than in control samples in both first biopsy samples and in combined first and last biopsy samples (P < 0.001). A frequency greater than the threshold (18.5 and 17.7, respectively) obtained by each receiver operating characteristic curve was an independent risk factor for PCa (P = 0.003 and 0.001, respectively) with odds ratios (14.8 and 13.9, respectively) higher than those of serum PSA titers of patients just before each biopsy (4.6 and 2.3, respectively). The number of P. acnes-positive macrophages did not differ significantly between PCa and control samples. These results suggested that the frequency of P. acnes-positive glands in the first negative prostate biopsy performed due to increased PSA titers can be supportive information for urologists in planning repeated biopsy or follow-up strategies.

  3. Transrectal-ultrasound prostatic biopsy preparation: rectal enema vs. mechanical bowel preparation.

    PubMed

    De Nunzio, Cosimo; Lombardo, Riccardo; Presicce, Fabrizio; Bellangino, Mariangela; Finazzi Agro, Enrico; Gambrosier, Matteo Bonetto; Trucchi, Alberto; Petta, Stefano; Tubaro, Andrea

    2015-01-01

    Transrectal prostate biopsy (TRUSbx) is the standard for the diagnosis of prostate cancer. Different bowel preparations are used for patients undergoing TRUSbx. The aim of our study was to compare two different bowel preparations for TRUSbx. From May 2012 and onwards, a selected group of men undergoing TRUS 12-core prostate biopsy were enrolled into a prospective database. Patients were randomized 1:1 to receive a rectal enema (Group A) the night before the procedure or polyethylene glycol 34.8 grams/4 liters of water the day before the procedure (Group B). A VAS scale to evaluate the patients' discomfort according to the two preparations was collected. The same antibiotic prophylaxis was performed in both groups. All complications were prospectively recorded and graded according to the Clavien Classification System (CCS). A total of 198 patients were consecutively enrolled. Mean age was 67.5 ±7.9 years, mean body mass index (BMI) was 27.1 ±4.2 Kg/m(2), mean PSA value was 9.3 ±12.6 ng/ml and the mean prostatic volume was 60.6 ±29 ml. 97 patients were enrolled in Group A and 101 in Group B. Overall post-biopsy morbidity rate was 60%. No significant differences for low-grade and high-grade complications was observed between the two groups. Patients receiving the rectal enema presented with a significantly lower VAS score (3.1 ±1.1 vs. 5.9 ±1.7; p = 0.02). Our study confirmed that a rectal enema should be considered as the standard bowel preparation in patients undergoing a TRUS biopsy; it is as effective as PEG and associated with less discomfort.

  4. Shearwave Dispersion Ultrasonic Vibrometry (SDUV) for measuring prostate shear stiffness and viscosity – An in vitro pilot study

    PubMed Central

    Urban, M.W.; Fatemi, M.; Greenleaf, J.F.

    2011-01-01

    This paper reports shear stiffness and viscosity “virtual biopsy” measurements of three excised non-cancerous human prostates using shearwave dispersion ultrasound vibrometry (SDUV) in vitro. Improved methods for prostate guided-biopsy are required to effectively guide needle biopsy to the suspected site. In addition, tissue stiffness measurement helps identifying a suspected site to perform biopsy because stiffness has been shown to correlate with pathology. More importantly, early detection of prostate cancer may guide minimally-invasive therapy and eliminate insidious procedures. In this work, “virtual” biopsies were taken in multiple locations in three excised prostates. Then, SDUV shear elasticity and viscosity measurements have been performed at the selected “suspicious” locations within the prostates. SDUV measurements of prostate elasticity and viscosity are generally in agreement with preliminary values reported previously in the literature. It is however important to emphasize that the obtained viscoelastic parameters values are local, and not a mean value for the whole prostate. PMID:20595086

  5. Efficacy and safety of fosfomycin-trometamol in the prophylaxis for transrectal prostate biopsy. Prospective randomized comparison with ciprofloxacin.

    PubMed

    Lista, F; Redondo, C; Meilán, E; García-Tello, A; Ramón de Fata, F; Angulo, J C

    2014-01-01

    Prostate biopsy is the standardized diagnostic method for prostate cancer. However, although there is not a standardized protocol, there are recommendations in order to reduce the incidence of complications. The objective of the present work is to assess the efficacy and safety of antibiotic prophylaxis in the prostate biopsy by comparing two antibiotic regimes: two doses of fosfomycin-trometamol 3g (FMT) every 48 hours with 10 doses of oral ciprofloxacin 500 mg every 12 hours during 5 days. Randomized prospective study was performed with 671 patients who had undergone to walking transrectal ultrasound guided prostate biopsy. Patients of group A (n=312) were treated with ciprofloxacin, and patients of group B (n=359) with FMT. Efficacy and tolerability of two prophylactic regimes were compared. Urine culture was carried out at 2 weeks after biopsy. Initially, patients with asymptomatic bacteriuria were not treated with antibiotics; urine culture was repeated after 1 month, persistent bacteriuria was treated according to antibiogram. No differences between groups were found in age (P=.78), cancer presence (P=.9) or number of biopsy cylinders (P=.93). The mean number of cores obtained was 11.3 ± 3.25 (range 6-20). Digestive intolerance was observed for 9 patients (2.9%) of group A and 10 patients (2.8%) in group B. One patient (.3%) of group A showed severe allergic reaction. In total, 167 patients (24.6%) had complications: 16 (2.4%) fever, 47 (6.9%) hemospermia, 81 (11.9%) hematuria, 7 (1%) rectal bleeding and 16 (2.4%) urinary retention. No statistically differences between groups were observed (27.6% vs. 22.6%; P=.17). However, hemospermia was more frequent in group A (9.9% vs. 4.5%; P=.006). Bacteriuria after biopsy was detected in 44 patients (6.6%), being more frequent in group B patients (4.2% vs. 8.6%; P=.02) although a higher number of second treatment cycles were not needed (53.9% vs. 29%; P=.17). The likelihood of resistance to ciprofloxacin in patients

  6. Diagnostic accuracy of a five-point Likert scoring system for magnetic resonance imaging (MRI) evaluated according to results of MRI/ultrasonography image-fusion targeted biopsy of the prostate.

    PubMed

    Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Ohe, Chisato; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S

    2018-01-01

    To evaluate the accuracy of a magnetic resonance imaging (MRI)-based Likert scoring system in the detection of clinically significant prostate cancer (CSPC), using MRI/ultrasonography (US) image-fusion targeted biopsy (FTB) as a reference standard. We retrospectively reviewed 1218 MRI-detected lesions in 629 patients who underwent subsequent MRI/US FTB between October 2012 and August 2015. 3-Tesla MRI was independently reported by one of eight radiologists with varying levels of experience and scored on a five-point Likert scale. All lesions with Likert scores 1-5 were prospectively defined as targets for MRI/US FTB. CSPC was defined as Gleason score ≥7. The median patient age was 64 years, PSA level 6.97 ng/mL and estimated prostate volume 52.2 mL. Of 1218 lesions, 48% (n = 581) were rated as Likert 1-2, 35% (n = 428) were Likert 3 and 17% (n = 209) were Likert 4-5. For Likert scores 1-5, the overall cancer detection rates were 12%, 13%, 22%, 50% and 59%, respectively, and the CSPC detection rates were 4%, 4%, 12%, 33% and 48%, respectively. Grading using the five-point scale showed strong positive correlation with overall cancer detection rate (r = 0.949, P = 0.05) and CSPC detection rate (r = 0.944, P = 0.05). By comparison, in Likert 4-5 lesions, significant differences were noted in overall cancer detection rate (63% vs 35%; P = 0.001) and CSPC detection rate (47% vs 29%; P = 0.027) for the more experienced vs the less experienced radiologists. The detection rates of overall cancer and CSPC strongly correlated with the five-point grading of the Likert scale. Among radiologists with different levels of experience, there were significant differences in these cancer detection rates. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  7. Evaluation of the breeding soundness of male camels (Camelus dromedarius) via clinical examination, semen analysis, ultrasonography and testicular biopsy: a summary of 80 clinical cases.

    PubMed

    Waheed, M M; Ghoneim, I M; Hassieb, M M; Alsumait, A A

    2014-10-01

    Male camel infertility is a heterogeneous disorder. A variety of factors may adversely affect sperm production and function and impair fertility. This study was designed to evaluate the sensitivity and specificity of ultrasonography and testicular biopsy in the evaluation of the breeding soundness of male dromedaries compared with results obtained by clinical examination and semen analysis. Eighty-four male dromedary camels (5-15 years old) were used in this study during the rutting season (November-May). Four sexually mature male camels were used as controls. These animals were apparently healthy and had histories of normal fertility. Eighty infertile male camels were subjected to an algorithmic approach based on information collected during careful examinations of the camels' breeding histories, clinical examinations, testicular evaluations, testicular ultrasonographies, the results of the semen analyses and testicular biopsies to diagnose the camels' infertilities. The differences in the semen parameters between the control and infertile male camels were highly significant (p < 0.01). Regarding the diagnoses of male camel infertility, the results of testicular ultrasonographies and biopsies were compared with those from the semen analyses, and the accuracies of these tests were 92.5% and 90%, respectively. Additionally, the results of the testicular ultrasonographies were matched with those of the testicular biopsies of the infertile animals, and this comparison resulted in 85% accuracy. Testicular biopsy is a promising method that, along with a carefully performed history, clinical examination, an appropriate testicular ultrasonography procedure and semen analysis, can afford veterinarians the opportunity for more precise diagnosis and treatment of many dromedary infertility disorders. © 2014 Blackwell Verlag GmbH.

  8. Re-examining Prostate-specific Antigen (PSA) Density: Defining the Optimal PSA Range and Patients for Using PSA Density to Predict Prostate Cancer Using Extended Template Biopsy.

    PubMed

    Jue, Joshua S; Barboza, Marcelo Panizzutti; Prakash, Nachiketh S; Venkatramani, Vivek; Sinha, Varsha R; Pavan, Nicola; Nahar, Bruno; Kanabur, Pratik; Ahdoot, Michael; Dong, Yan; Satyanarayana, Ramgopal; Parekh, Dipen J; Punnen, Sanoj

    2017-07-01

    To compare the predictive accuracy of prostate-specific antigen (PSA) density vs PSA across different PSA ranges and by prior biopsy status in a prospective cohort undergoing prostate biopsy. Men from a prospective trial underwent an extended template biopsy to evaluate for prostate cancer at 26 sites throughout the United States. The area under the receiver operating curve assessed the predictive accuracy of PSA density vs PSA across 3 PSA ranges (<4 ng/mL, 4-10 ng/mL, >10 ng/mL). We also investigated the effect of varying the PSA density cutoffs on the detection of cancer and assessed the performance of PSA density vs PSA in men with or without a prior negative biopsy. Among 1290 patients, 585 (45%) and 284 (22%) men had prostate cancer and significant prostate cancer, respectively. PSA density performed better than PSA in detecting any prostate cancer within a PSA of 4-10 ng/mL (area under the receiver operating characteristic curve [AUC]: 0.70 vs 0.53, P < .0001) and within a PSA >10 mg/mL (AUC: 0.84 vs 0.65, P < .0001). PSA density was significantly more predictive than PSA in detecting any prostate cancer in men without (AUC: 0.73 vs 0.67, P < .0001) and with (AUC: 0.69 vs 0.55, P < .0001) a previous biopsy; however, the incremental difference in AUC was higher among men with a previous negative biopsy. Similar inferences were seen for significant cancer across all analyses. As PSA increases, PSA density becomes a better marker for predicting prostate cancer compared with PSA alone. Additionally, PSA density performed better than PSA in men with a prior negative biopsy. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Asymptomatic prostatic inflammation in men with clinical BPH and erectile dysfunction affects the positive predictive value of prostate-specific antigen.

    PubMed

    Agnihotri, Shalini; Mittal, Rama Devi; Kapoor, Rakesh; Mandhani, Anil

    2014-10-01

    To test the hypothesis that sexual dysfunction in elderly men with benign prostatic hyperplasia leads to prostatic inflammation, diagnosed by prostatic fluid interleukin-8 (IL-8), which lowers the positive predictive value of prostate-specific antigen (PSA). Overall, 160 men with lower urinary tract symptoms between 50 and 75 years of age with an elevated PSA level of more than 4 ng/ml with normal digital rectal examination and 50 age-matched controls with normal PSA level were prospectively evaluated for prostatic fluid IL-8 levels. Erectile dysfunction was measured by self-administered questionnaire of the Sexual Health Inventory for Men. Total and free serum PSA levels and IL-8 in prostatic fluid were measured 6 to 8 weeks after a course of 400mg of ofloxacin and 20mg of piroxicam given daily for 2 weeks. Transrectal ultrasonography-guided biopsy was done only when PSA level did not decrease less than 4 ng/ml. Mean ages of patients and controls were 63.18 (standard deviation [SD]±7.10) and 60.18 (SD+6.02) years, respectively. Mean concentration of IL-8 in prostatic fluid of the patients was significantly higher, i.e., 6678 pg/ml (SD±1985.7) than in control, i.e., 1543 pg/ml (SD±375.7) (P<0.001). Following anti-inflammatory treatment, there was a significant decrease in the mean level of IL-8 from baseline to 5622 pg/ml (SD±1870.66) (P<0.001). Corresponding to this, a significant decrease was noted in total PSA levels to less than 4 ng/ml in 105 (65.62%) patients. Men with the highest levels of IL-8 had a greater degree of erectile dysfunction. Men with symptomatic benign prostatic hyperplasia and erectile dysfunction had significant inflammation of the prostate to cause spurious rise in PSA level resulting in an unnecessary biopsy. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. The best prostate biopsy scheme is dictated by the gland volume: a monocentric study.

    PubMed

    Dell'Atti, L

    2015-08-01

    Accuracy of biopsy scheme depends on different parameters. Prostate-specific antigen (PSA) level and digital rectal examination (DRE) influenced the detection rate and suggested the biopsy scheme to approach each patient. Another parameter is the prostate volume. Sampling accuracy tends to decrease progressively with an increasing prostate volume. We prospectively observed detection cancer rate in suspicious prostate cancer (PCa) and improved by applying a protocol biopsy according to prostate volume (PV). Clinical data and pathological features of these 1356 patients were analysed and included in this study. This protocol is a combined scheme that includes transrectal (TR) 12-core PBx (TR12PBx) for PV ≤ 30 cc, TR 14-core PBx (TR14PBx) for PV > 30 cc but < 60 cc, TR 18-core PBx (TR18PBx) for PV ≥ 60 cc. Out of a total of 1356 patients, in 111 (8.2%) PCa was identified through TR12PBx scheme, in 198 (14.6%) through TR14PBx scheme and in 253 (18.6%) through TR18PBx scheme. The PCa detection rate was increased by 44% by adding two TZ cores (TR14PBx scheme). The TR18PBx scheme increased this rate by 21.7% vs. TR14PBx scheme. The diagnostic yield offered by TR18PBx was statistically significant compared to the detection rate offered by the TR14PBx scheme (p < 0.003). The biopsy Gleason score and the percentage of core involvement were comparable between PCa detected by the TR14PBx scheme diagnostic yield and those detected by the TR18PBx scheme (p = 0.362). The only PV parameter, in our opinion, can be significant in choosing the best biopsy scheme to approach in a first setting of biopsies increasing PCa detection rate.

  11. Analysis of "dry" mesothelioma with ultrasound guided biopsies.

    PubMed

    Stigt, Jos A; Boers, James E; Groen, Harry J M

    2012-12-01

    Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. CT-guided fine-needle biopsy of focal lung lesions as the method for reducing the number of invasive diagnostic procedures

    PubMed Central

    Chodorowska, Anna; Rzechonek, Adam; Dyła, Tomasz; Muszczyńska-Bernhard, Beata; Adamek, Jarosław

    2010-01-01

    Summary Background: CT-guided fine-needle biopsy (FNB) of focal lung lesions is one of the possibilities of obtaining histopathological diagnosis in pulmonary diseases. Its place in the algorithm is determined by the invasiveness. In case of no diagnosis after bronchoscopy or endobronchial ultrasonography (EBUS) guided biopsy, CT-guided FNB can become an alternative for more invasive procedures, such as open lung biopsy – thoracotomy. Material/Methods: Since January 2009 until February 2010, we performed 37 CT-guided FNB in 34 patients aged 31 to 76 (mean age 60.9). Among them, there were 16 women and 18 men. All patients underwent a standard chest CT with contrast medium injection. They were diagnosed with focal lesions and they were rejected from surgery as the primary method of treatment. During biopsy, the patient was positioned prone or supine, depending on the location of lesions. After performing a scout image and initial slices, we marked the level of biopsy, using a metal marker. Next, the biopsy needle was introduced under local anesthesia. When the obtained position of the needle in the lesion was correct, the specimen was taken. After needle removal, the patient was controlled for the presence of complications (i.e. pneumothorax). Biopsy time ranged from 10 to 50 minutes. Results: In 94.6% of biopsies, the specimens for histopathological and cytological examinations were obtained. In 22 (64.7%) patients, histopathological diagnoses (in 14 cases this was the non-small cell cancer and in 8, inflammatory lesions) were established which allowed us to resign from invasive thoracotomy and to introduce an appropriate treatment. In the remaining 12 patients, no diagnosis was established. Complications in the form of a minor pneumothorax occurred in 2 patients. Conclusions: Fine-needle biopsy of the focal lung lesions is an affective and a relatively safe method, which can replace the more invasive diagnostic thoracotomy in the majority of patients. PMID

  13. High-resolution rapid diagnostic imaging of whole prostate biopsies using video-rate fluorescence structured illumination microscopy

    PubMed Central

    Wang, Mei; Kimbrell, Hillary Z.; Sholl, Andrew B.; Tulman, David B.; Elfer, Katherine N.; Schlichenmeyer, Tyler C.; Lee, Benjamin R.; Lacey, Michelle; Brown, J. Quincy

    2015-01-01

    Rapid assessment of prostate core biopsy pathology at the point-of-procedure could provide benefit in a variety of clinical situations. Even with advanced trans-rectal ultrasound guidance and saturation biopsy protocols, prostate cancer can be missed in up to half of all initial biopsy procedures. In addition, collection of tumor specimens for downstream histological, molecular, and genetic analysis is hindered by low tumor yield due to inability to identify prostate cancer grossly. However, current point-of-procedure pathology protocols such as frozen section analysis (FSA) are destructive, and too time- and labor-intensive to be practical or economical. Ex vivo microscopy of the excised specimens, stained with fast-acting fluorescent histology dyes, could be an attractive non-destructive alternative to FSA. In this work, we report the first demonstration of video-rate structured illumination microscopy (VR-SIM) for rapid high-resolution diagnostic imaging of prostate biopsies in realistic point-of-procedure timeframes. Large mosaic images of prostate biopsies stained with acridine orange are rendered in seconds, and contain excellent contrast and detail, exhibiting close correlation with corresponding H&E histology. A clinically-relevant review of VR-SIM images of 34 unfixed and uncut prostate core biopsies by two independent pathologists resulted in an area under the ROC curve (AUC) of 0.82–0.88, with a sensitivity ranging from 63–88% and a specificity ranging from 78–89%. When biopsies contained more than 5% tumor content, the sensitivity improved to 75–92%. The image quality, speed, minimal complexity, and ease of use of VR-SIM could prove to be features in favor of adoption as an alternative to destructive pathology at the point-of-procedure. PMID:26282168

  14. Magnetic resonance/transrectal ultrasound fusion biopsy of the prostate compared to systematic 12-core biopsy for the diagnosis and characterization of prostate cancer: multi-institutional retrospective analysis of 389 patients.

    PubMed

    Mariotti, Guilherme C; Costa, Daniel N; Pedrosa, Ivan; Falsarella, Priscila M; Martins, Tatiana; Roehrborn, Claus G; Rofsky, Neil M; Xi, Yin; M Andrade, Thais C; Queiroz, Marcos R; Lotan, Yair; Garcia, Rodrigo G; Lemos, Gustavo C; Baroni, Ronaldo H

    2016-09-01

    To determine the incremental diagnostic value of targeted biopsies added to an extended sextant biopsy scheme on a per-patient, risk-stratified basis in 2 academic centers using different multiparametric magnetic resonance imaging (MRI) protocols, a large group of radiologists, multiple biopsy systems, and different biopsy operators. All patients with suspected prostate cancer (PCa) who underwent multiparametric MRI of the prostate in 2 academic centers between February 2013 and January 2015 followed by systematic and targeted MRI-transrectal ultrasound fusion biopsy were reviewed. Risk-stratified detection rate using systematic biopsies was compared with targeted biopsies on a per-patient basis. The McNemar test was used to compare diagnostic performance of the 2 approaches. A total of 389 men met eligibility criteria. PCa was diagnosed in 47% (182/389), 52%(202/389), and 60%(235/389) of patients using the targeted, systematic, and combined (targeted plus systematic) approach, respectively. Compared with systematic biopsy, targeted biopsy diagnosed 11% (37 vs. 26) more intermediate-to-high risk (P<0.0001) and 16% (10 vs. 16) fewer low-risk tumors (P<0.0001). These results were replicated when data from each center, biopsy-naïve patients, and men with previous negative biopsies were analyzed separately. Targeted MRI-transrectal ultrasound fusion biopsy consistently improved the detection of clinically significant PCa in a large patient cohort with diverse equipment, protocols, radiologists, and biopsy operators as can be encountered in clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Post-void residual urinary volume is an independent predictor of biopsy results in men at risk for prostate cancer.

    PubMed

    Cormio, Luigi; Lucarelli, Giuseppe; Netti, Giuseppe Stefano; Stallone, Giovanni; Selvaggio, Oscar; Troiano, Francesco; Di Fino, Giuseppe; Sanguedolce, Francesca; Bufo, Pantaleo; Grandaliano, Giuseppe; Carrieri, Giuseppe

    2015-04-01

    to determine whether peak flow rate (PFR) and post-void residual urinary volume (PVRUV) predict prostate biopsy outcome. The study population consisted of 1780 patients undergoing first prostate biopsy. Patients with prostate cancer (PCa) had significantly greater prostate-specific antigen (PSA) and PFR but lower prostate volume (PVol) and PVRUV than those without PCa. Receiver operator characteristic curve analysis showed that PVol and PVRUV were the most accurate predictors of biopsy outcome. The addition of PVRUV to the multivariate logistic regression model based on standard clinical parameters (age, PSA, digital rectal examination, PVol) significantly increased the predictive accuracy of the model in both the population overall (79% vs. 77%; p=0.001) and patients with PSA levels up to 10 ng/ml (74.3% vs. 71.7%; p=0.005). PVRUV seems to be an accurate non-invasive test to predict biopsy outcome that can be used alone or in combination with PVol in the decision-making process for men potentially facing a prostate biopsy. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  16. [Estimating minimum period of time to perform prostate MRI after prostate biopsy: Clinical and histological bleeding risk factors; from a prospective study].

    PubMed

    Sarradin, M; Lepiney, C; Celhay, O; Delpech, P O; Charles, T; Pillot, P; Bernardeau, S; Tasu, J P; Irani, J

    2018-02-01

    A minimum delay of 4 to 6 weeks between biopsy and multiparametric prostatic MRI (mpMRI) is admitted due to post-biopsy hemorrhage that can impact MRI reading without strong scientific evidence. The objective of the study was to evaluate the best period between prostate biopsy and 3Tesla mpMRI and searching for predictive factors of intraprostatic blood. A prostate biopsy followed by a 4-week prostate MRI (MRIp M1) was performed. In case of hemorrhage, MRI was rescheduled at 8 and 12 weeks (M2/M3). We analyzed the persistant bleeding to identify risk factors: anticoagulant/antiaggregant, post-biopsy side effects, histological criteria. In this prospective, single-center study, we included 40 patients followed for suspected prostate cancer between December 2014 and March 2016. At the MRIpM1, blood was found for 97.5 % of the patients. The rates were 90.9 % and 88.9 % respectively at the M2 and M3 mpMRI. Compared to initial blood volume on MRIpM1, a significant decrease in blood volume was observed between M1 and M2 (55 %; P=0.0091). We showed a 75 % decrease between M1 and M3 (P=0.0003). Low urinary tract symptoms (LUTS) suggesting urinary infection at 4 weeks were significantly correlated with blood volume on MRIpM1 (P=0.0063). The blood volume was higher in case of unconformity between biopsy and mpMRI results for detection of significant tumors (11.3 vs. 2.3; P=0.0051). A minimum of 8-week biopsy and mpMRI period would limit post-biopsy hemorrhage, predicted by LUTS suggesting urinary infection. A delay of 12 weeks would be optimal without delaying the management of the patient. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Impact of Prostate-specific Antigen (PSA) Screening Trials and Revised PSA Screening Guidelines on Rates of Prostate Biopsy and Postbiopsy Complications.

    PubMed

    Gershman, Boris; Van Houten, Holly K; Herrin, Jeph; Moreira, Daniel M; Kim, Simon P; Shah, Nilay D; Karnes, R Jeffrey

    2017-01-01

    Prostate biopsy and postbiopsy complications represent important risks of prostate-specific antigen (PSA) screening. Although landmark randomized trials and updated guidelines have challenged routine PSA screening, it is unclear whether these publications have affected rates of biopsy or postbiopsy complications. To evaluate whether publication of the 2008 and 2012 US Preventive Services Task Force (USPSTF) recommendations, the 2009 European Randomized Study of Screening for Prostate Cancer and the Prostate, Lung, Colorectal, and Ovarian Cancer Screening Trial, or the 2013 American Urological Association (AUA) guidelines was associated with changes in rates of biopsy or postbiopsy complications, and to identify predictors of postbiopsy complications. This quasiexperimental study used administrative claims of 5279315 commercially insured US men aged ≥40 yr from 2005 to 2014, of whom 104584 underwent biopsy. Publications on PSA screening. Interrupted time-series analysis was used to evaluate the association of publications with rates of biopsy and 30-d complications. Logistic regression was performed to identify predictors of complications. From 2005 to 2014, biopsy rates fell 33% from 64.1 to 42.8 per 100000 person-months, with immediate reductions following the 2008 USPSTF recommendations (-10.1; 95% confidence interval [CI], -17.1 to -3.0; p<0.001), 2012 USPSTF recommendations (-13.8; 95% CI, -21.0 to -6.7; p<0 .001), and 2013 AUA guidelines (-8.8; 95% CI, -16.7 to -0.92; p=0.03). Concurrently, complication rates decreased 10% from 8.7 to 7.8 per 100000 person-months, with a reduction following the 2012 USPSTF recommendations (-2.5; 95% CI, -4.5 to -0.45; p=0.02). However, the proportion of men undergoing biopsy who experienced complications increased from 14% to 18%, driven by nonsepsis infectious complications (p<0.001). Predictors of complications included prior fluoroquinolone use (odds ratio [OR]: 1.27; 95% CI, 1.22-1.32; p<0.001), anticoagulant use (OR: 1

  18. Magnetic Resonance Imaging-Guided Transurethral Ultrasound Ablation of Prostate Tissue in Patients with Localized Prostate Cancer: A Prospective Phase 1 Clinical Trial.

    PubMed

    Chin, Joseph L; Billia, Michele; Relle, James; Roethke, Matthias C; Popeneciu, Ionel V; Kuru, Timur H; Hatiboglu, Gencay; Mueller-Wolf, Maya B; Motsch, Johann; Romagnoli, Cesare; Kassam, Zahra; Harle, Christopher C; Hafron, Jason; Nandalur, Kiran R; Chronik, Blaine A; Burtnyk, Mathieu; Schlemmer, Heinz-Peter; Pahernik, Sascha

    2016-09-01

    Magnetic resonance imaging-guided transurethral ultrasound ablation (MRI-TULSA) is a novel minimally invasive technology for ablating prostate tissue, potentially offering good disease control of localized cancer and low morbidity. To determine the clinical safety and feasibility of MRI-TULSA for whole-gland prostate ablation in a primary treatment setting of localized prostate cancer (PCa). A single-arm prospective phase 1 study was performed at three tertiary referral centers in Canada, Germany, and the United States. Thirty patients (median age: 69 yr; interquartile range [IQR]: 67-71 yr) with biopsy-proven low-risk (80%) and intermediate-risk (20%) PCa were treated and followed for 12 mo. MRI-TULSA treatment was delivered with the therapeutic intent of conservative whole-gland ablation including 3-mm safety margins and 10% residual viable prostate expected around the capsule. Primary end points were safety (adverse events) and feasibility (technical accuracy and precision of conformal thermal ablation). Exploratory outcomes included quality of life, prostate-specific antigen (PSA), and biopsy at 12 mo. Median treatment time was 36min (IQR: 26-44) and prostate volume was 44ml (IQR: 38-48). Spatial control of thermal ablation was ±1.3mm on MRI thermometry. Common Terminology Criteria for Adverse Events included hematuria (43% grade [G] 1; 6.7% G2), urinary tract infections (33% G2), acute urinary retention (10% G1; 17% G2), and epididymitis (3.3% G3). There were no rectal injuries. Median pretreatment International Prostate Symptom Score 8 (IQR: 5-13) returned to 6 (IQR: 4-10) at 3 mo (mean change: -2; 95% confidence interval [CI], -4 to 1). Median pretreatment International Index of Erectile Function 13 (IQR: 6-28) recovered to 13 (IQR: 5-25) at 12 mo (mean change: -1; 95% CI, -5 to 3). Median PSA decreased 87% at 1 mo and was stable at 0.8 ng/ml (IQR: 0.6-1.1) to 12 mo. Positive biopsies showed 61% reduction in total cancer length, clinically significant

  19. Prostate health index and prostate cancer gene 3 score but not percent-free Prostate Specific Antigen have a predictive role in differentiating histological prostatitis from PCa and other nonneoplastic lesions (BPH and HG-PIN) at repeat biopsy.

    PubMed

    De Luca, Stefano; Passera, Roberto; Fiori, Cristian; Bollito, Enrico; Cappia, Susanna; Mario Scarpa, Roberto; Sottile, Antonino; Franco Randone, Donato; Porpiglia, Francesco

    2015-10-01

    To determine if prostate health index (PHI), prostate cancer antigen gene 3 (PCA3) score, and percentage of free prostate-specific antigen (%fPSA) may be used to differentiate asymptomatic acute and chronic prostatitis from prostate cancer (PCa), benign prostatic hyperplasia (BPH), and high-grade prostate intraepithelial neoplasia (HG-PIN) in patients with elevated PSA levels and negative findings on digital rectal examination at repeat biopsy (re-Bx). In this prospective study, 252 patients were enrolled, undergoing PHI, PCA3 score, and %fPSA assessments before re-Bx. We used 3 multivariate logistic regression models to test the PHI, PCA3 score, and %fPSA as risk factors for prostatitis vs. PCa, vs. BPH, and vs. HG-PIN. All the analyses were performed for the whole patient cohort and for the "gray zone" of PSA (4-10ng/ml) cohort (171 individuals). Of the 252 patients, 43 (17.1%) had diagnosis of PCa. The median PHI was significantly different between men with a negative biopsy and those with a positive biopsy (34.9 vs. 48.1, P<0.001), as for the PCA3 score (24 vs. 54, P<0.001) and %fPSA (11.8% vs. 15.8%, P = 0.012). The net benefit of using PCA3 and PHI to differentiate prostatitis and PCa was moderate, although it extended to a good range of threshold probabilities (40%-100%), whereas that from using %fPSA was negligible: this pattern was reported for the whole population as for the "gray zone" PSA cohort. In front of a good diagnostic performance of all the 3 biomarkers in distinguishing negative biopsy vs. positive biopsy, the clinical benefit of using the PCA3 score and PHI to estimate prostatitis vs. PCa was comparable. PHI was the only determinant for prostatitis vs. BPH, whereas no biomarkers could differentiate prostate inflammation from HG-PIN. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    PubMed

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  1. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  2. Prostate health index significantly reduced unnecessary prostate biopsies in patients with PSA 2-10 ng/mL and PSA >10 ng/mL: Results from a Multicenter Study in China.

    PubMed

    Na, Rong; Ye, Dingwei; Qi, Jun; Liu, Fang; Helfand, Brian T; Brendler, Charles B; Conran, Carly A; Packiam, Vignesh; Gong, Jian; Wu, Yishuo; Zheng, Siqun L; Mo, Zengnan; Ding, Qiang; Sun, Yinghao; Xu, Jianfeng

    2017-08-01

    The performance of prostate health index (phi) in predicting prostate biopsy outcomes has been well established for patients with prostate-specific antigen (PSA) values between 2 and 10 ng/mL. However, the performance of phi remains unknown in patients with PSA >10 ng/mL, the vast majority in Chinese biopsy patients. We aimed to assess the ability of phi to predict prostate cancer (PCa) and high-grade disease (Gleason Score ≥7) on biopsy in a Chinese population. This is a prospective, observational, multi-center study of consecutive patients who underwent a transrectal ultrasound guided prostate biopsy at four hospitals in Shanghai, China from August 2013 to December 2014. In the cohort of 1538 patients, the detection rate of PCa was 40.2%. phi had a significantly better predictive performance for PCa than total PSA (tPSA). The areas under the receiver operating characteristic curve (AUC) were 0.90 and 0.79 for phi and tPSA, respectively, P < 0.0001. A considerable proportion of patients in the cohort had PSAs >10 ng/mL (N = 838, 54.5%). The detection rates of PCa were 35.9% and 57.7% in patients with tPSA 10.1-20 and 20.1-50 ng/mL, respectively. The AUCs of phi (0.79 and 0.89, for these two groups, respectively) were also significantly higher than tPSA (0.57 and 0.63, respectively), both P < 0.0001. If a phi ≤35 was used as the cutoff, 599/1538 (39%) biopsies could have been avoided at a cost of missing small numbers of PCa patients: 49 (7.93%) PCa patients, including 18 (3.69%) high-grade tumors. Results from this study suggest that phi can be used to predict PCa and high-grade disease in Chinese men with high PSA levels (>10 ng/mL). © 2017 Wiley Periodicals, Inc.

  3. Rapid increase in multidrug-resistant enteric bacilli blood stream infection after prostate biopsy - A 10-year population-based cohort study.

    PubMed

    Aly, Markus; Dyrdak, Robert; Nordström, Tobias; Jalal, Shah; Weibull, Caroline E; Giske, Christian G; Grönberg, Henrik

    2015-06-15

    Bloodstream infection following a transrectal prostate biopsy is a well-known and feared complication. Previous studies have shown an increase in multi-resistant bacterial infections as a consequence of higher usage of antibiotics in investigated populations. Our aim was to analyze bacterial resistance patterns in positive blood cultures, after prostate biopsies in Stockholm, Sweden, where the use of antibiotics has been low and decreasing during the last 10 years. From the three pathology laboratories in Stockholm, reports of prostate examinations were retrieved (n = 56,076) from 2003 to 2012. By linking men to the National Patient Register all but prostate core biopsies were excluded (n = 12,024). Prostate biopsies in men younger than 30 years of age were excluded (n = 5) leaving 44,047 biopsies for analysis. From laboratory information systems data regarding blood cultures were retrieved. Proportions of blood cultures within 30 days by year were calculated. Crude and adjusted logistic regression models were used to estimate ORs. In total, 44,047 prostate biopsies were performed in 32,916 men over 10 years. On 620 occasions a blood culture was drawn within 30 days of the biopsy; 266 of these were positive. The proportions with positive blood cultures in 2003 and 2012 were 0.38 and 1.14%, respectively. The proportion of multidrug-resistant bacteria increased significantly during the study. In the crude and the adjusted analysis, the year of biopsy and Charlson Comorbidity Index were associated with the risk of having a positive blood culture. Multidrug-resistant enteric bacilli are becoming a problem in Sweden, despite low antimicrobial use. Men need to be informed about the increasing risks of infectious complications of transrectal prostate biopsy. One out of 50 men undergoing a prostate biopsy will develop symptoms suggestive of a bloodstream infection after the biopsy and one in 100 men will have a positive blood culture. © 2015 Wiley Periodicals

  4. Risk factors for infection development after transrectal prostate biopsy and the role of resistant bacteria in colonic flora.

    PubMed

    Eruz, Emine Dilek; Yalci, Aysun; Ozden, Eriz; Aslaner, Halide; Ogucu-Durgun, Suna; Koseoglu-Taymur, Deniz Derya; Memikoglu, Kemal Osman; Erdem, Hakan; Kurt, Halil

    2017-02-28

    In this study, we aimed to identify risk factors for the development of infectious complications after prostate biopsy and to investigate the role of intestinal colonization of bacteria that are resistant to prophylactic antibiotics. A total of 168 patients who had undergone transrectal prostate biopsy (TRPB) under ciprofloxacin and gentamycin prophylaxis were included in the study. Stool cultures and subsequent antibiotic susceptibility testing were performed in all patients before the start of antibiotic prophylaxis. Of the 168 patients, 17 (10.1%) developed urinary tract infection (UTI), while 6 (3.57%) developed sepsis within seven days after biopsy. Ciprofloxacin-resistant bacterial colonization was detected in 81 (48.2%) of the patients. None of the patients with ciprofloxacin-sensitive bacteria in intestinal flora developed a UTI. The colonization of intestinal ciprofloxacin-resistant bacteria increased UTI risk significantly after TRPB (p < 0.0001). Urolithiasis history, presence of permanent urinary catheterization, hospitalization history for more than 48 hours in the last year, and recent antibiotic usage significantly increased UTI risk after TRPB. Development of an infection was more frequent in patients with resistant bacterial colonization. We hope to guide more comprehensive studies designed to find a standard prophylactic regimen for TRPB that can be used all over the world.

  5. Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sparks, Rachel, E-mail: rachel.sparks@ucl.ac.uk; Barratt, Dean; Nicolas Bloch, B.

    2015-03-15

    Purpose: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. Inmore » this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. Methods: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. Results: MAPPER was evaluated on 13 patient studies from two independent datasets—Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2

  6. Proteins Annexin A2 and PSA in Prostate Cancer Biopsies Do Not Predict Biochemical Failure.

    PubMed

    Lamb, David S; Sondhauss, Sven; Dunne, Jonathan C; Woods, Lisa; Delahunt, Brett; Ferguson, Peter; Murray, Judith; Nacey, John N; Denham, James W; Jordan, T William

    2017-12-01

    We previously reported the use of mass spectrometry and western blotting to identify proteins from tumour regions of formalin-fixed paraffin-embedded biopsies from 16 men who presented with apparently localized prostate cancer, and found that annexin A2 (ANXA2) appeared to be a better predictor of subsequent biochemical failure than prostate-specific antigen (PSA). In this follow-up study, ANXA2 and PSA were measured using western blotting of proteins extracted from biopsies from 37 men from a subsequent prostate cancer trial. No significant differences in ANXA2 and PSA levels were observed between men with and without biochemical failure. The statistical effect sizes were small, d=0.116 for ANXA2, and 0.266 for PSA. ANXA2 and PSA proteins measured from biopsy tumour regions are unlikely to be good biomarkers for prediction of the clinical outcome of prostate cancer presenting with apparently localized disease. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  7. Enrichment of prostate cancer stem cells from primary prostate cancer cultures of biopsy samples

    PubMed Central

    Wang, Shunqi; Huang, Shengsong; Zhao, Xin; Zhang, Qimin; Wu, Min; Sun, Feng; Han, Gang; Wu, Denglong

    2014-01-01

    This study was to enrich prostate cancer stem cells (PrCSC) from primary prostate cancer cultures (PPrCC). Primary prostate cancer cells were amplified in keratinocyte serum-free medium with epidermal growth factor (EGF) and bovine pituitary extract (BPE), supplemented with leukemia inhibitory factor (LIF), stem cell factor (SCF) and cholera toxin. After amplification, cells were transferred into ultra-low attachment dishes with serum-free DMEM/F12 medium, supplemented with EGF, basic fibroblast growth factor (bFGF), bovine serum albumin (BSA), insulin, and N2 nutrition. Expression of cell-type-specific markers was determined by RT-qPCR and immunostaining. Tumorigenicity of enriched PrCSC was determined by soft agar assay and xenograft assay in NOD/SCID mice. Biopsy samples from 19 confirmed prostate cancer patients were used for establishing PPrCC, and 18 cases (95%) succeeded. Both basal marker (CK5) and luminal markers (androgen receptor and CK8) strongly co-expressed in most of PPrCC, indicating their basal epithelial origin. After amplification under adherent culture condition in vitro, transient amplifying cells were the dominant cells. Sphere formation efficiency (SFE) of passaged PPrCC was about 0.5%, which was 27 times lower than SFE of LNCaP (13.67%) in the same condition. Compared with adherent cells from PPrCC, prostasphere from PPrCC showed up regulated stem cell markers and increased tumorigenic potential in soft-agar assay. However, spheroid cells from PPrCC prostasphere failed to initiate tumor in xenograft assay in 6 months. Thus, PPrCC can be established and amplified from prostate cancer biopsy samples. Our modified sphere culture system can enrich PrCSC from PPrCC. PMID:24427338

  8. Clinical utility of an epigenetic assay to detect occult prostate cancer in histopathologically negative biopsies: results of the MATLOC study.

    PubMed

    Stewart, Grant D; Van Neste, Leander; Delvenne, Philippe; Delrée, Paul; Delga, Agnès; McNeill, S Alan; O'Donnell, Marie; Clark, James; Van Criekinge, Wim; Bigley, Joseph; Harrison, David J

    2013-03-01

    Concern about possible false-negative prostate biopsy histopathology findings often leads to rebiopsy. A quantitative methylation specific polymerase chain reaction assay panel, including GSTP1, APC and RASSF1, could increase the sensitivity of detecting cancer over that of pathological review alone, leading to a high negative predictive value and a decrease in unnecessary repeat biopsies. The MATLOC study blindly tested archived prostate biopsy needle core tissue samples of 498 subjects from the United Kingdom and Belgium with histopathologically negative prostate biopsies, followed by positive (cases) or negative (controls) repeat biopsy within 30 months. Clinical performance of the epigenetic marker panel, emphasizing negative predictive value, was assessed and cross-validated. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay performed on the first negative biopsies of this retrospective review cohort resulted in a negative predictive value of 90% (95% CI 87-93). In a multivariate model correcting for patient age, prostate specific antigen, digital rectal examination and first biopsy histopathological characteristics the epigenetic assay was a significant independent predictor of patient outcome (OR 3.17, 95% CI 1.81-5.53). A multiplex quantitative methylation specific polymerase chain reaction assay determining the methylation status of GSTP1, APC and RASSF1 was strongly associated with repeat biopsy outcome up to 30 months after initial negative biopsy in men with suspicion of prostate cancer. Adding this epigenetic assay could improve the prostate cancer diagnostic process and decrease unnecessary repeat biopsies. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Feasibility of Prostate Cancer Diagnosis by Transrectal Photoacoustic Imaging

    DTIC Science & Technology

    2012-03-01

    cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the prostate. Transrectal ultrasound has...been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for detecting prostate cancer due to...Research Systems, CA) and used as a reference signal. The sample and the ultrasound transducer (UST, Olympus NDT, one inch in focal length) are

  10. Prostate-specific antigen (PSA) density in the diagnostic algorithm of prostate cancer.

    PubMed

    Nordström, Tobias; Akre, Olof; Aly, Markus; Grönberg, Henrik; Eklund, Martin

    2018-04-01

    Screening for prostate cancer using prostate-specific antigen (PSA) alone leads to un-necessary biopsying and overdiagnosis. PSA density is easily accessible, but early evidence on its use for biopsy decisions was conflicting and use of PSA density is not commonly recommended in guidelines. We analyzed biopsy outcomes in 5291 men in the population-based STHLM3 study with PSA ≥ 3 ng/ml and ultrasound-guided prostate volume measurements by using percentages and regression models. PSA density was calculated as total PSA (ng/ml) divided by prostate volume (ml). Main endpoint was clinically significant cancer (csPCa) defined as Gleason Score ≥ 7. The median PSA-density was 0.10 ng/ml 2 (IQR 0.075-0.14). PSA-density was associated with the risk of finding csPCa both with and without adjusting for the additional clinical information age, family history, previous biopsies, total PSA and free/total PSA (OR 1.06; 95% CI:1.05-1.07 and OR 1.07, 95% CI 1.06-1.08). Discrimination for csPCa was better when PSA density was added to a model with additional clinical information (AUC 0.75 vs. 0.73, P < 0.05). The proportion of men with Gleason Score 6 (ISUP 1) was similar across stratas of PSA-density. Omitting prostate biopsy for men with PSA-density ≤0.07 ng/ml 2 would save 19.7% of biopsy procedures, while missing 6.9% of csPCa. PSA-density cutoffs of 0.10 ng/ml 2 and 0.15 ng/ml 2 resulted in detection of 77% (729/947) and 49% (461/947) of Gleason Score ≥7 tumors. PSA-density might inform biopsy decisions, and spare some men from the morbidity associated with a prostate biopsy and diagnosis of low-grade prostate cancer.

  11. A multiparametric magnetic resonance imaging-based risk model to determine the risk of significant prostate cancer prior to biopsy.

    PubMed

    van Leeuwen, Pim J; Hayen, Andrew; Thompson, James E; Moses, Daniel; Shnier, Ron; Böhm, Maret; Abuodha, Magdaline; Haynes, Anne-Maree; Ting, Francis; Barentsz, Jelle; Roobol, Monique; Vass, Justin; Rasiah, Krishan; Delprado, Warick; Stricker, Phillip D

    2017-12-01

    To develop and externally validate a predictive model for detection of significant prostate cancer. Development of the model was based on a prospective cohort including 393 men who underwent multiparametric magnetic resonance imaging (mpMRI) before biopsy. External validity of the model was then examined retrospectively in 198 men from a separate institution whom underwent mpMRI followed by biopsy for abnormal prostate-specific antigen (PSA) level or digital rectal examination (DRE). A model was developed with age, PSA level, DRE, prostate volume, previous biopsy, and Prostate Imaging Reporting and Data System (PIRADS) score, as predictors for significant prostate cancer (Gleason 7 with >5% grade 4, ≥20% cores positive or ≥7 mm of cancer in any core). Probability was studied via logistic regression. Discriminatory performance was quantified by concordance statistics and internally validated with bootstrap resampling. In all, 393 men had complete data and 149 (37.9%) had significant prostate cancer. While the variable model had good accuracy in predicting significant prostate cancer, area under the curve (AUC) of 0.80, the advanced model (incorporating mpMRI) had a significantly higher AUC of 0.88 (P < 0.001). The model was well calibrated in internal and external validation. Decision analysis showed that use of the advanced model in practice would improve biopsy outcome predictions. Clinical application of the model would reduce 28% of biopsies, whilst missing 2.6% significant prostate cancer. Individualised risk assessment of significant prostate cancer using a predictive model that incorporates mpMRI PIRADS score and clinical data allows a considerable reduction in unnecessary biopsies and reduction of the risk of over-detection of insignificant prostate cancer at the cost of a very small increase in the number of significant cancers missed. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  12. Design and preliminary accuracy studies of an MRI-guided transrectal prostate intervention system.

    PubMed

    Krieger, Axel; Csoma, Csaba; Iordachital, Iulian I; Guion, Peter; Singh, Anurag K; Fichtinger, Gabor; Whitcomb, Louis L

    2007-01-01

    This paper reports a novel system for magnetic resonance imaging (MRI) guided transrectal prostate interventions, such as needle biopsy, fiducial marker placement, and therapy delivery. The system utilizes a hybrid tracking method, comprised of passive fiducial tracking for initial registration and subsequent incremental motion measurement along the degrees of freedom using fiber-optical encoders and mechanical scales. Targeting accuracy of the system is evaluated in prostate phantom experiments. Achieved targeting accuracy and procedure times were found to compare favorably with existing systems using passive and active tracking methods. Moreover, the portable design of the system using only standard MRI image sequences and minimal custom scanner interfacing allows the system to be easily used on different MRI scanners.

  13. Sonoelastographic evaluation with the determination of compressibility ratio for symmetrical prostatic regions in the diagnosis of clinically significant prostate cancer

    PubMed Central

    Słapa, Rafał Z.; Jakubowski, Wiesław S.; Migda, Bartosz; Dmowski, Tadeusz

    2014-01-01

    Aim Sonoelastography is a technique that assesses tissue hardness/compressibility. Utility and sensitivity of the method in prostate cancer diagnostics were assessed compared to the current gold standard in prostate cancer diagnostics i.e. systematic biopsy. Material and methods The study involved 84 patients suspected of prostate cancer based on elevated PSA levels or abnormal per rectal examination findings. Sonoelastography was used to evaluate the prostate gland. In the case of regions with hardness two-fold greater than that of symmetric prostate area (strain ratio >2), targeted biopsy was used; which was followed by an ultrasound-guided 8- or 10-core systematic biopsy (regardless of sonoelastography-indicated sites) as a reference point. Results The mean age of patients was 69 years. PSA serum levels ranged between 1.02 and 885 ng/dl. The mean prostate volume was 62 ml (19–149 ml). Prostate cancer was found in 39 out of 84 individuals. Statistically significant differences in strain ratios between cancers and benign lesions were shown. Sonoelastography guided biopsy revealed 30 lesions – overall sensitivity 77% (sensitivity of the method – 81%). Sonoelastographic sensitivity increased depending on cancer stage according to the Gleason grading system: 6–60%, 7–75%, 8–83%, 9/10–100%. The estimated sensitivity of systematic biopsy was 92%. Conclusions Sonoelastography shows higher diagnostic sensitivity in prostate cancer diagnostics compared to conventional imaging techniques, i.e. grey-scale TRUS, Doppler ultrasound. It allows to reduce the number of collected tissue cores, and thus limit the incidence of complications as well as the costs involved. Sonoelastography using the determination of compressibility ratio for symmetrical prostatic regions may prove useful in the detection of clinically significant prostate cancer. PMID:26674065

  14. [A comparison between prostatic volume measured during suprapubic ultrasonography (TAUS) and volume of the enucleated gland after open prostatectomy].

    PubMed

    Szewczyk, Wojciech; Prajsner, Andrzej; Kozina, Janusz; Login, Tomasz; Kaczorowski, Marek

    2004-01-01

    General practitioner very often uses transabdominal ultrasonograpy (TAUS) in order to measure prostatic volume. Using this method it is rather impossible to distinguish between tissue of benign prostatic hyperplasia (BPH) and prostatic tissue which forms so called surgical capsule of BPH. The aim of this study was a comparison of prostatic volume measured during suprapubic (transabdominal) ultrasonography and volume of the enucleated gland after open prostatectomy. Regarding the results authors created a nomogram based on TAUS measurement of the prostate which helps to predict the volume of BPH. They also stated that surgical capsule of the BPH makes about 1/3 of the whole volume of the prostate measured by TAUS.

  15. Probability modeling of the number of positive cores in a prostate cancer biopsy session, with applications.

    PubMed

    Serfling, Robert; Ogola, Gerald

    2016-02-10

    Among men, prostate cancer (CaP) is the most common newly diagnosed cancer and the second leading cause of death from cancer. A major issue of very large scale is avoiding both over-treatment and under-treatment of CaP cases. The central challenge is deciding clinical significance or insignificance when the CaP biopsy results are positive but only marginally so. A related concern is deciding how to increase the number of biopsy cores for larger prostates. As a foundation for improved choice of number of cores and improved interpretation of biopsy results, we develop a probability model for the number of positive cores found in a biopsy, given the total number of cores, the volumes of the tumor nodules, and - very importantly - the prostate volume. Also, three applications are carried out: guidelines for the number of cores as a function of prostate volume, decision rules for insignificant versus significant CaP using number of positive cores, and, using prior distributions on total tumor size, Bayesian posterior probabilities for insignificant CaP and posterior median CaP. The model-based results have generality of application, take prostate volume into account, and provide attractive tradeoffs of specificity versus sensitivity. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Percentage of free prostate-specific antigen (PSA) is a useful method in deciding to perform prostate biopsy with higher core numbers in patients with low PSA cut-off values.

    PubMed

    Yilmaz, Hasan; Ciftci, Seyfettin; Yavuz, Ufuk; Ustuner, Murat; Saribacak, Ali; Dillioglugil, Ozdal

    2015-06-01

    The aim of this study was to evaluate the predictive role of percentage of free prostate-specific antigen (%fPSA) cut-points in prostate cancer (PCa) detection in patients with total PSA (tPSA) levels between 2.5 ng/mL and 10.0 ng/mL. In total, 1321 consecutive initial transrectal ultrasound (TRUS)-guided 12-core biopsies performed between 2005 and 2011 were evaluated retrospectively. Benign pathologies, high-grade prostatic intraepithelial neoplasia, and atypical small acinary proliferations were categorized as noncancerous (benign), and prostate adenocarcinomas were categorized as cancerous (malignant). The patients were categorized according to: Catalona's published %fPSA categories (<10%, 10-15%, 15-20%, 20-25%, or > 25%); digital rectal examination (DRE) results [benign (negative) or suspicious of malignancy (positive)]. There was a significant relationship between the %fPSA cut-points and detection of PCa in DRE-negative patients. The presence of a 10% cut-point increased the probability of PCa threefold. The %fPSA was significantly more related to PCa than the tPSA value in receiver operating characteristic (ROC) curve analyses (p = 0.001). Based on our findings, a lower %fPSA, especially <10%, is an important parameter when deciding whether to perform a biopsy on patients with a tPSA between 2.5 ng/mL and 10 ng/mL. Copyright © 2015. Published by Elsevier Taiwan.

  17. Fully Automated Prostate Magnetic Resonance Imaging and Transrectal Ultrasound Fusion via a Probabilistic Registration Metric.

    PubMed

    Sparks, Rachel; Bloch, B Nicolas; Feleppa, Ernest; Barratt, Dean; Madabhushi, Anant

    2013-03-08

    In this work, we present a novel, automated, registration method to fuse magnetic resonance imaging (MRI) and transrectal ultrasound (TRUS) images of the prostate. Our methodology consists of: (1) delineating the prostate on MRI, (2) building a probabilistic model of prostate location on TRUS, and (3) aligning the MRI prostate segmentation to the TRUS probabilistic model. TRUS-guided needle biopsy is the current gold standard for prostate cancer (CaP) diagnosis. Up to 40% of CaP lesions appear isoechoic on TRUS, hence TRUS-guided biopsy cannot reliably target CaP lesions and is associated with a high false negative rate. MRI is better able to distinguish CaP from benign prostatic tissue, but requires special equipment and training. MRI-TRUS fusion, whereby MRI is acquired pre-operatively and aligned to TRUS during the biopsy procedure, allows for information from both modalities to be used to help guide the biopsy. The use of MRI and TRUS in combination to guide biopsy at least doubles the yield of positive biopsies. Previous work on MRI-TRUS fusion has involved aligning manually determined fiducials or prostate surfaces to achieve image registration. The accuracy of these methods is dependent on the reader's ability to determine fiducials or prostate surfaces with minimal error, which is a difficult and time-consuming task. Our novel, fully automated MRI-TRUS fusion method represents a significant advance over the current state-of-the-art because it does not require manual intervention after TRUS acquisition. All necessary preprocessing steps (i.e. delineation of the prostate on MRI) can be performed offline prior to the biopsy procedure. We evaluated our method on seven patient studies, with B-mode TRUS and a 1.5 T surface coil MRI. Our method has a root mean square error (RMSE) for expertly selected fiducials (consisting of the urethra, calcifications, and the centroids of CaP nodules) of 3.39 ± 0.85 mm.

  18. Design of a Teleoperated Needle Steering System for MRI-guided Prostate Interventions

    PubMed Central

    Seifabadi, Reza; Iordachita, Iulian; Fichtinger, Gabor

    2013-01-01

    Accurate needle placement plays a key role in success of prostate biopsy and brachytherapy. During percutaneous interventions, the prostate gland rotates and deforms which may cause significant target displacement. In these cases straight needle trajectory is not sufficient for precise targeting. Although needle spinning and fast insertion may be helpful, they do not entirely resolve the issue. We propose robot-assisted bevel-tip needle steering under MRI guidance as a potential solution to compensate for the target displacement. MRI is chosen for its superior soft tissue contrast in prostate imaging. Due to the confined workspace of the MRI scanner and the requirement for the clinician to be present inside the MRI room during the procedure, we designed a MRI-compatible 2-DOF haptic device to command the needle steering slave robot which operates inside the scanner. The needle steering slave robot was designed to be integrated with a previously developed pneumatically actuated transperineal robot for MRI-guided prostate needle placement. We describe design challenges and present the conceptual design of the master and slave robots and the associated controller. PMID:24649480

  19. Patient identification error among prostate needle core biopsy specimens--are we ready for a DNA time-out?

    PubMed

    Suba, Eric J; Pfeifer, John D; Raab, Stephen S

    2007-10-01

    Patient identification errors in surgical pathology often involve switches of prostate or breast needle core biopsy specimens among patients. We assessed strategies for decreasing the occurrence of these uncommon and yet potentially catastrophic events. Root cause analyses were performed following 3 cases of patient identification error involving prostate needle core biopsy specimens. Patient identification errors in surgical pathology result from slips and lapses of automatic human action that may occur at numerous steps during pre-laboratory, laboratory and post-laboratory work flow processes. Patient identification errors among prostate needle biopsies may be difficult to entirely prevent through the optimization of work flow processes. A DNA time-out, whereby DNA polymorphic microsatellite analysis is used to confirm patient identification before radiation therapy or radical surgery, may eliminate patient identification errors among needle biopsies.

  20. Greater Biopsy Core Number Is Associated With Improved Biochemical Control in Patients Treated With Permanent Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bittner, Nathan; Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.or; Galbreath, Robert W.

    2010-11-15

    Purpose: Standard prostate biopsy schemes underestimate Gleason score in a significant percentage of cases. Extended biopsy improves diagnostic accuracy and provides more reliable prognostic information. In this study, we tested the hypothesis that greater biopsy core number should result in improved treatment outcome through better tailoring of therapy. Methods and Materials: From April 1995 to May 2006, 1,613 prostate cancer patients were treated with permanent brachytherapy. Patients were divided into five groups stratified by the number of prostate biopsy cores ({<=}6, 7-9, 10-12, 13-20, and >20 cores). Biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) were evaluatedmore » as a function of core number. Results: The median patient age was 66 years, and the median preimplant prostate-specific antigen was 6.5 ng/mL. The overall 10-year bPFS, CSS, and OS were 95.6%, 98.3%, and 78.6%, respectively. When bPFS was analyzed as a function of core number, the 10-year bPFS for patients with >20, 13-20, 10-12, 7-9 and {<=}6 cores was 100%, 100%, 98.3%, 95.8%, and 93.0% (p < 0.001), respectively. When evaluated by treatment era (1995-2000 vs. 2001-2006), the number of biopsy cores remained a statistically significant predictor of bPFS. On multivariate analysis, the number of biopsy cores was predictive of bPFS but did not predict for CSS or OS. Conclusion: Greater biopsy core number was associated with a statistically significant improvement in bPFS. Comprehensive regional sampling of the prostate may enhance diagnostic accuracy compared to a standard biopsy scheme, resulting in better tailoring of therapy.« less

  1. Cancer Localization in the Prostate with F-18 Fluorocholine Positron Emission Tomography

    DTIC Science & Technology

    2007-01-01

    INTRODUCTION Prostate cancer is the second leading cause of cancer death in American men over 50 years of age. Ultrasound - guided prostate biopsy is...currently the most common method for diagnosing and localizing cancer in the prostate. However, even when standard 6 or 12 needle biopsy templates... needles employed (1, 2). While progress has been made in the detection of primary prostate cancer using imaging techniques such as ultrasound and

  2. Is it possible to predict low-volume and insignificant prostate cancer by core needle biopsies?

    PubMed

    Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas; Brasso, Klaus; Vainer, Ben; Iversen, Peter

    2013-04-01

    In an attempt to minimize overtreatment of localized prostate cancer (PCa) active surveillance (AS) and minor invasive procedures have received increased attention. We investigated the accuracy of pre-operative findings in defining insignificant disease and distinguishing between unilateral/unifocal and bilateral/multifocal PCa. One-hundred and sixty patients undergoing radical prostatectomy were included. Histology reports from the biopsies and matching prostatectomies were compared. Three definitions of insignificant cancer were used: InsigE: tumour volume ≤0.5 mL; InsigW: tumour volume ≤1.3 mL; InsigM: tumour ≤5% of total prostate volume and prostate-specific antigen (PSA) ≤10 ng/mL. In all definitions, Gleason score (GS) was ≤6 and the tumour was organ confined. Biopsies alone performed poorly as a predictor of unifocal and unilateral cancer in the prostatectomy specimens with positive predictive values of 17.8% and 18.9% respectively. Inclusion of other clinical and biochemical parameters did not significantly increase the predictive value. However, the combination of GS ≤ 6, PSA ≤ 10 ng/mL and unifocal or unilateral cancer in biopsy cores resulted in a positive predictive value of 61.1%, 38.9% and 12.0%, respectively, for identifying InsigM, InsigW and InsigE in the prostate specimen. Conclusively, routine prostate biopsies cannot predict unifocal and unilateral PCa, and must be regarded insufficient to select patients for focal therapy. Although candidates for AS may be identified using standard biopsies, a considerable fraction of patients will be understaged. There is a need for more precise diagnostic tools to assess intraprostatic tumour growth. © 2012 The Authors APMIS © 2012 APMIS.

  3. Prostate Cancer Detection and Diagnosis: The Role of MR and its Comparison to other Diagnostic Modalities – A Radiologist's Perspective

    PubMed Central

    Penzkofer, Tobias; Tempany-Afdhal, Clare M.

    2013-01-01

    It is now universally recognized that many prostate cancers are over-diagnosed and over-treated. The European Randomized Study of Screening for Prostate Cancer (ERSPC) from 2009 evidenced that, to save one man from death of prostate cancer, over 1,400 men had to be screened, and 48 had to undergo treatment. Detection of prostate cancer is traditionally based upon digital rectal examination (DRE) and measuring serum prostate specific antigen (PSA), followed by ultrasound guided biopsy. The primary role of imaging for the detection and diagnosis of prostate cancer has been transrectal ultrasound (TRUS) guidance during biopsy. MRI has traditionally been used primarily for staging disease in men with biopsy proven cancer. It is has a well-established role in detecting T3 disease, planning radiation therapy, especially 3D conformal or intensity modulated external beam radiation therapy (IMRT), and planning and guiding interstitial seed implant or brachytherapy. New advances have now established prostate MRI can accurately characterize focal lesions within the gland, an ability that has led to new opportunities for improved cancer detection and guidance for biopsy. There are two new approaches to prostate biopsy are under investigation both use pre-biopsy MRI to define potential targets for sampling and then the biopsy is performed either with direct real-time MR guidance (in-bore) or MR fusion/registration with TRUS images (out-of-bore). In-bore or out-of-bore MRI-guided prostate biopsies have the advantage of using the MR target definition for accurate localization and sampling of targets or suspicious lesions. The out-of-bore method uses combined MRI/TRUS with fusion software that provided target localization and increases the sampling accuracy for TRUS-guided biopsies by integrating prostate MRI information with TRUS. Newer parameters for each imaging modality such as sonoelastography or shear wave elastography (SWE), contrast enhanced US (CEUS) and MRI

  4. Magnetic resonance imaging in prostate cancer detection and management: a systematic review.

    PubMed

    Monni, Fabio; Fontanella, Paolo; Grasso, Angelica; Wiklund, Peter; Ou, Yen-Chuan; Randazzo, Marco; Rocco, Bernardo; Montanari, Emanuele; Bianchi, Giampaolo

    2017-12-01

    The aim of our work was to evaluate the role of multi-parametric magnetic resonance imaging (mpMRI) in detection and management of prostate cancer (PC); specifically investigating the efficacy of mpMRI-based biopsy techniques in terms of diagnostic yield of significant prostate neoplasm and the improved management of patients who choose conservative treatments or active surveillance. A systematic and critical analysis through Medline, Embase, Scopus and Web of Science databases was carried out in March 2016, following the PRISMA ("Preferred Reporting Items for Systematic Reviews and Meta-Analyses") statement. The search was conducted using the following key words: "MRI/TRUS-fusion biopsy," "PIRADS," "prostate cancer," "magnetic resonance imaging (MRI)," "multiparametric MRI (mpMRI)," "systematic prostate biopsy (SB)," "targeted prostate biopsy (TPB)." English language articles were reviewed for inclusion ability. Sixty-six studies were selected in order to evaluate the characteristics and limitations of traditional sample biopsy, the role of mpMRI in detection of PC, specifically the increased degree of diagnostic accuracy of targeted prostate biopsy compared to systematic biopsy (12 cores), and to transperineal saturation biopsies with trans-rectal ultrasound (TRUS) only. MpMRI can detect index lesions in approximately 90% of cases when compared to prostatectomy specimen. The diagnostic performance of biparametric MRI (T2w + DWI) is not inferior to mpMRI, offering valid options to diminish cost- and time-consumption. Since approximately 10% of significant lesions are still MRI-invisible, systematic cores biopsy seem to still be necessary. The analysis of the different techniques shows that in-bore MRI-guided biopsy and MRI/TRUS-fusion-guided biopsy are superior in detection of significant PC compared to visual estimation alone. MpMRI proved to be very effective in active surveillance, as it prevents underdetection of significant PC and it assesses low-risk disease

  5. Ratio of prostate specific antigen to the outer gland volume of prostrate as a predictor for prostate cancer.

    PubMed

    Zhang, Hai-Min; Yan, Yang; Wang, Fang; Gu, Wen-Yu; Hu, Guang-Hui; Zheng, Jun-Hua

    2014-01-01

    As a definite diagnosis of prostate cancer, puncture biopsy of the prostate is invasive method. The aim of this study was to evaluate the value of OPSAD (the ratio of PSA to the outer gland volume of prostate) as a non-invasive screening and diagnosis method for prostate cancer in a select population. The diagnosis data of 490 subjects undergoing ultrasound-guided biopsy of the prostate were retrospectively analyzed. This included 133 patients with prostate cancer, and 357 patients with benign prostate hyperplasia (BPH). The OPSAD was significantly greater in patients with prostate cancer (1.87 ± 1.26 ng/ml(2)) than those with BPH (0.44 ± 0.21 ng/ml(2)) (P < 0.05). Receiver operating characteristic (ROC) curve analysis revealed that the performance of OPSAD as a diagnostic tool is superior to PSA and PSAD for the diagnosis of prostate cancer. In the different groups divided according to the Gleason score of prostate cancer, OPSAD is elevated with the rise of the Gleason score. OPSAD may be used as a new indicator for the diagnosis and prognosis of prostate cancer, and it can reduce the use of unnecessary puncture biopsy of the prostate.

  6. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less

  7. MRI-guided Breast Biopsy: Outcomes and Impact on Patient Management

    PubMed Central

    Kamel, Ihab R; Macura, Katarzyna J

    2014-01-01

    Introduction The purpose of this study was to correlate the pathology results of magnetic resonance imaging (MRI)-guided breast biopsies at our institution to MRI findings and patient clinical history characteristics. The impact of MRI-guided breast biopsies on surgical management in patients with a new diagnosis of breast cancer was also assessed. Patients and Methods In this HIPAA-compliant study we retrospectively reviewed all MRI-guided breast biopsies performed 3/2006–5/2012. Clinical history, MRI features and pathology outcomes were reviewed. In patients undergoing breast MRI to evaluate extent of disease, any change in surgical management resulting from the MRI-guided biopsy was recorded. Statistical analysis included binary logistic regression and independent student’s t-test. Results Two-hundred fifteen lesions in 168 patients were included, of which 23 (10.7%) were malignant, 43 (20%) were high risk, and 149 (69.3%) were benign. No clinical characteristic was associated with malignancy in our cohort. MRI features associated with malignancy were: larger size (mean 2.6 cm versus 1.3 cm, p=0.046), washout kinetics (18% malignancy rate, p=0.02) and marked background parenchymal enhancement (40% malignancy rate, p-value <0.001 to 0.03). Nineteen (28%) of the 67 patients with a new diagnosis of breast cancer undergoing MRI-guided breast biopsy had a change in surgical management based on the biopsy result. Conclusions Malignancy rate was associated with lesion size, washout kinetics and marked background enhancement of the breast parenchyma but was not associated with any clinical history characteristics. Pre-operative MRI-guided breast biopsies changed surgical management in 28% of women with a new diagnosis of breast cancer. PMID:25499596

  8. Impact of a preoperatively estimated prostate volume using transrectal ultrasonography on surgical and oncological outcomes in a single surgeon's experience with robot-assisted radical prostatectomy.

    PubMed

    Hirasawa, Yosuke; Ohno, Yoshio; Nakashima, Jun; Shimodaira, Kenji; Hashimoto, Takeshi; Gondo, Tatsuo; Ohori, Makoto; Tachibana, Masaaki; Yoshioka, Kunihiko

    2016-09-01

    To assess the impact of preoperatively estimated prostate volume (PV) using transrectal ultrasonography (TRUS) on surgical and oncological outcomes in robot-assisted radical prostatectomy (RARP). We analyzed the experience of a single surgeon at our hospital who performed 436 RARPs without neoadjuvant hormone therapy between August 2006 and December 2013. Patients were divided into three groups according to their preoperative PV calculated using TRUS (PV ≤ 20 cm(3): group 1, n = 61; 20 < PV < 50 cm(3): group 2, n = 303; PV ≥ 50 cm(3): group 3, n = 72). Blood loss was significantly higher in group 3 than in group 1 and group 2. In stage pT2 patients, the rate of positive surgical margin (PSM) was significantly lower in group 3 than in group 1. In addition, perioperative complications significantly increased with increasing PV, while the extraprostatic extension (EPE) rate significantly decreased with increasing PV. The preoperative biopsy Gleason score, prostate-specific antigen (PSA) density, and clinical T2 stage were inversely correlated with increasing PV. Biochemical recurrence-free survival after RARP was significantly lower in group 1 than in groups 2 and 3. A large prostate size was significantly associated with increased blood loss and a higher rate of perioperative complications. A small prostate size was associated with a higher PSM rate, PSA density, Gleason score, EPE rate, and biochemical recurrence rate. These results suggest that RARP was technically challenging in patients with large prostates, whereas small prostates were associated with unfavorable oncological outcomes.

  9. Prostate calculi in cancer and BPH in a cohort of Korean men: presence of calculi did not correlate with cancer risk

    PubMed Central

    Hwang, Eu-Chang; Choi, Hyang-Sik; Im, Chang-Min; Jung, Seung-Il; Kim, Sun-Ouck; Kang, Taek-Won; Kwon, Dong-Deuk; Park, Kwang-Sung; Ryu, Soo-Bang

    2010-01-01

    Prostatic calculi are common and are associated with inflammation of the prostate. Recently, it has been suggested that this inflammation may be associated with prostate carcinogenesis. The aim of this study was to investigate the relationship between prostatic calculi and prostate cancer (PCa) in prostate biopsy specimens. We retrospectively analyzed 417 consecutive patients who underwent transrectal ultrasonography (TRUS) and prostate biopsies between January 2005 and January 2008. Based on the biopsy findings, patients were divided into benign prostatic hyperplasia and PCa groups. TRUS was used to detect prostatic calculi and to measure prostate volume. The correlations between PCa risk and age, serum total PSA levels, prostate volume, and prostatic calculi were analyzed. Patient age and PSA, as well as the frequency of prostatic calculi in the biopsy specimens, differed significantly between both the groups (P < 0.05). In the PCa group, the Gleason scores (GSs) were higher in patients with prostatic calculi than in patients without prostatic calculi (P = 0.023). Using multivariate logistic regression analysis, we found that patient age, serum total PSA and prostate volume were risk factors for PCa (P = 0.001), but that the presence of prostatic calculi was not associated with an increased risk of PCa (P = 0.13). In conclusion, although the presence of prostatic calculi was not shown to be a risk factor for PCa, prostatic calculi were more common in patients with PCa and were associated with a higher GS among these men. PMID:20037598

  10. Cognitive versus Software-Assisted Registration: Development of a New Nomogram Predicting Prostate Cancer at MRI-Targeted Biopsies.

    PubMed

    Kaufmann, Sascha; Russo, Giorgio I; Thaiss, Wolfgang; Notohamiprodjo, Mike; Bamberg, Fabian; Bedke, Jens; Morgia, Giuseppe; Nikolaou, Konstantin; Stenzl, Arnulf; Kruck, Stephan

    2018-04-03

    Multiparametric magnetic resonance imaging (mpMRI) is gaining acceptance to guide targeted biopsy (TB) in prostate cancer (PC) diagnosis. We aimed to compare the detection rate of software-assisted fusion TB (SA-TB) versus cognitive fusion TB (COG-TB) for PC and to evaluate potential clinical features in detecting PC and clinically significant PC (csPC) at TB. This was a retrospective cohort study of patients with rising and/or persistently elevated prostate-specific antigen (PSA) undergoing mpMRI followed by either transperineal SA-TB or transrectal COG-TB. The analysis showed a matched-paired analysis between SA-TB versus COG-TB without differences in clinical or radiological characteristics. Differences among detection of PC/csPC among groups were analyzed. A multivariable logistic regression model predicting PC at TB was fitted. The model was evaluated using the receiver operating characteristic-derived area under the curve, goodness of fit test, and decision-curve analyses. One hundred ninety-one and 87 patients underwent SA-TB or COG-TB, respectively. The multivariate logistic analysis showed that SA-TB was associated with overall PC (odds ratio [OR], 5.70; P < .01) and PC at TB (OR, 3.00; P < .01) but not with overall csPC (P = .40) and csPC at TB (P = .40). A nomogram predicting PC at TB was constructed using the Prostate Imaging Reporting and Data System version 2.0, age, PSA density and biopsy technique, showing improved clinical risk prediction against a threshold probability of 10% with a c-index of 0.83. In patients with suspected PC, software-assisted biopsy detects most cancers and outperforms the cognitive approach in targeting magnetic resonance imaging-visible lesions. Furthermore, we introduced a prebiopsy nomogram for the probability of PC in TB. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Psychological impact of serial prostate-specific antigen tests in Japanese men waiting for prostate biopsy.

    PubMed

    Kobayashi, Minoru; Nukui, Akinori; Kamai, Takao

    2017-02-01

    It is common to repeat prostate-specific antigen (PSA) measurements for men with intermediate PSA elevation before prostate biopsy. In this scenario, men with persistently elevated PSA values may have considerable psychological distress. We attempted to determine whether elevated PSA values have psychological effects on these men in association with the timing of measurement, PSA kinetics, and biopsy results. In order to investigate the initial and late effects of PSA tests on psychological distress during serial measurements, two groups of men with screen-positive results (PSA ≥3 ng/ml) were studied-205 men whose first questionnaires regarding anxiety and depression were taken at initial screening (group A), and 103 men whose questionnaires were taken at repeated measurement for prior PSA elevation (group B). The level of distress was generally low. There were no significant differences in distress between the two groups, suggesting a constant psychological effect by elevated PSA values over a long period of time. The distress of men in group A increased significantly as PSA levels rose and decreased when they fell to normal range. On the other hand, the distress of men in group B did not change regardless of PSA kinetics, indicating that their psychological condition seemed susceptible to subtle PSA change only in the initial phase of measurements. Unexpectedly, men with benign results showed insignificant but higher distress after prostate biopsy. Although a small fraction of men have psychological distress caused by changes in PSA levels, the benefits, risks (psychological and physical), and limitations of PSA tests must be adequately explained to the patients before entering the screening program.

  12. Asymptomatic Benign Papilloma Without Atypia Diagnosed at Ultrasonography-Guided 14-Gauge Core Needle Biopsy: Which Subgroup can be Managed by Observation?

    PubMed

    Kim, Soo-Yeon; Kim, Eun-Kyung; Lee, Hye Sun; Kim, Min Jung; Yoon, Jung Hyun; Koo, Ja Seung; Moon, Hee Jung

    2016-06-01

    For asymptomatic benign papillomas detected at ultrasonography-guided 14-gauge core-needle biopsy (US-CNB), the decision to perform excision versus observation has been a topic of debate. We sought to determine which subgroup of asymptomatic benign papillomas without atypia diagnosed at US-CNB can be safely managed by observation versus immediate excision. Overall, 230 asymptomatic benign papillomas in 197 women (mean age 46.6 ± 9.5 years; range 22-78), diagnosed at US-CNB using immunohistochemistry staining when needed and then managed by surgery (n = 144) or vacuum-assisted excision (VAE) with at least 12 months of follow-up after benign VAE results (n = 86) were included in this study. The upgrade rate to malignancy was calculated. Clinical and radiological variables, including age, size, Breast Image Reporting and Data System (BI-RADS) category, and imaging-pathology correlation were evaluated to find associations with malignancy using multivariate analysis. The upgrade rate to malignancy was 2.6 % (6 of 230): four were ductal carcinomas in situ and two were 1.5- and 9-mm-sized invasive ductal carcinomas without lymph node metastasis. The upgrade rates of papillomas with a BI-RADS category 3-4a and imaging-pathology concordance were 1.4 and 1.8 %, respectively. Category 4b-5 and imaging-pathology discordance were independently associated with malignancy, with upgrade rates of 13 and 50 %, respectively. Age and lesion size were not associated with malignancy. Asymptomatic benign papillomas with probable benign or low suspicious US features or imaging-pathology concordance can be followed-up as opposed to immediate excision.

  13. The impact of race on prostate cancer detection and choice of treatment in men undergoing a contemporary extended biopsy approach.

    PubMed

    Swords, Kelly; Wallen, Eric M; Pruthi, Raj S

    2010-01-01

    African American men have a higher rate of prostate cancer mortality compared with their Caucasian American counterparts. However, it remains unclear as to whether such differences are due to biologic or socioeconomic influences. This study sought to determine if there are differences in demographic and clinical characteristics between African American and Caucasian American men in a modern cohort undergoing extended biopsy approach, and evaluated the subsequent choice of therapy in patients diagnosed with prostate cancer. A retrospective review was performed from a consecutive series of 500 men undergoing prostate biopsy at our institution between 2003 and 2005. All patients underwent a contemporary 10-12 biopsy scheme. Demographic, clinical, and pathologic variables as well as treatment choice (those with positive biopsy) were stratified and evaluated with regard to race-African American, Caucasian American, and other (Hispanic, Asian, American Indian). 65% were Caucasian American, 29% African American, and 7% other. The overall positive biopsy rate was 44%. African American men were significantly younger than Caucasian American but were not younger than "other" (61.6 vs. 64.3 vs. 61.5 years). No differences were observed with regard to prostate specific antigen density (PSAD), prostate volume, or rate of abnormal digital rectal exam (DRE). The positive biopsy rate was not different between Caucasian American and African American (46% vs. 46%), but significantly lower in other men (16%). These differences were maintained on odds ratio modeling, including age-adjusted and multivariate models. Of the 223 men with positive biopsies, information on treatment choice demonstrated that African American men had a significantly higher rate of choice of XRT (OR = 2.12) and rate of avoidance of surgery (OR = 0.35) than Caucasian American men. In men undergoing prostate biopsy using an extended (10-12 core) biopsy scheme, no differences were observed with regard to positive

  14. Comparison of different local anesthesia techniques during TRUS-guided biopsies: a prospective pilot study.

    PubMed

    Kravchick, Sergey; Peled, Ronit; Ben-Dor, David; Dorfman, Dov; Kesari, David; Cytron, Shmuel

    2005-01-01

    To introduce two forms of anesthesia and compare them with standard local anesthesia techniques. A total of 114 consecutive patients underwent prostate needle biopsy. The patients were sequentially randomized to receive different kinds of anesthesia: 2% rectal lidocaine gel, 40% dimethyl sulfoxide (DMSO) with lidocaine, perianal injection of 1% lidocaine, or periprostatic nerve block. Pain perception was separately assessed for probe insertion and biopsies using a visual pain analog score. One-way analysis of variance was used to compare the data scale among the four groups. A linear regression model was used to define the independent variables that predicted the level of pain. The groups were similar in terms of age, prostate-specific antigen levels, digital rectal examination findings, prostate volume, pain tolerance, biopsy time, and number of cores taken. The lowest pain scores for probe insertion were for the perianal injection and DMSO/lidocaine groups (0.89 and 1.38, respectively). The difference between these scores and those for the other two groups was statistically significant (P <0.001). Pain perception during biopsy did not differ significantly among the DMSO/lidocaine, perianal, or periprostatic groups and was greatest in the lidocaine gel group (4.147; P <0.001). We did not observe any statistically significant correlation between the pain level during probe insertion and biopsy and pain tolerance (P = 0.514 and P = 0.788, respectively). The anesthesia type was the strongest single predictor of the pain level during biopsy (P <0.001). The use of 40% DMSO with lidocaine instilled into the rectal vault for 10 minutes avoids any need for injection and is capable of decreasing the discomfort or pain experienced during probe insertion and prostate biopsy comparable to the perianal and periprostatic protocols.

  15. [Hospitalization rate in relation to severe complications of transrectal prostate biopsy: About 2715 patients biopsied].

    PubMed

    Tamarelle, B; Perrin, P; Devonec, M; Paparel, P; Ruffion, A

    To identify hospitalizations directly related to a complication occurring within 30 days following a transrectal prostate biopsy (PBP). Overall hospitalization rates, mortality rates, potential predisposing factors for complications. Single-center study including all patients who underwent PBP between January 2005 and January 2012. Any hospitalization occurring within 30 days of the PBP for urgent motive was considered potentially attributable to biopsy. We identified the reason for hospitalization with direct complications (urinary infection or fever, rectal bleeding, bladder caillotage, retention) and indirect (underlying comorbidities decompensation) of the biopsy. The contributing factors were anticoagulant or antiplatelet treatment well as waning immunity factors (corticosteroid therapy, HIV, chemotherapy or immunodulateur). Among 2715 men who underwent PBP, there were 120 (4.4%) hospitalizations including 28 (1.03%) caused by the biopsy. Twenty-five (0.92%) were related to a direct complication of biopsy: 14 (56%) for urinary tract infection or fever including 1 hospitalization in intensive care, 5 (20%) for rectal bleeding which required several transfusions 1, 10 (40%) urinary retention and 3 (0.11%) for an indirect complication (2 coronary syndromes and 1 respiratory failure). Several direct complications were associated in 3 cases. Only two hospitalizations associated with rectal bleeding were taking an antiplatelet or anticoagulant. There was no association between hospitalization for urinary tract infections and a decreased immune status. The first death observed in our study occurred at D31 of pulmonary embolism (advanced metastatic patient with bladder cancer). Twenty (60.6%) patients urgently hospitalized did not have prostate cancer. Within this large sample of patients the overall rate of hospitalization due to the realization of a PBP was 1%. It has not been found predictive of complications leading to hospitalization. 4. Copyright © 2016

  16. Performance of serum prostate-specific antigen isoform [-2]proPSA (p2PSA) and the prostate health index (PHI) in a Chinese hospital-based biopsy population.

    PubMed

    Na, Rong; Ye, Dingwei; Liu, Fang; Chen, Haitao; Qi, Jun; Wu, Yishuo; Zhang, Guiming; Wang, Meilin; Wang, Wenying; Sun, Jielin; Yu, Guopeng; Zhu, Yao; Ren, Shancheng; Zheng, S Lilly; Jiang, Haowen; Sun, Yinghao; Ding, Qiang; Xu, Jianfeng

    2014-11-01

    The use of serum [-2]proPSA (p2PSA) and its derivative, the prostate health index (PHI), in detecting prostate cancer (PCa) have been consistently shown to have better performance than total prostate-specific antigen (tPSA) in discriminating biopsy outcomes in western countries. However, little is known about their performance in Chinese men. Our objective is to test the performance of p2PSA and PHI and their added value to tPSA in discriminating biopsy outcomes in Chinese men. Consecutive patients who underwent prostate biopsy in three tertiary hospitals in Shanghai, China during 2012-2013 were recruited. Serum tPSA, free PSA (fPSA), and p2PSA were measured centrally using Beckman Coulter's DxI 800 Immunoassay System. The primary outcome is PCa and the secondary outcome is high-grade PCa (Gleason Score of 4 + 3 or worse). Discriminative performance was assessed using the area under the receiver operating characteristic curve (AUC), detection rate and Decision Curve Analysis (DCA). Among 636 patients who underwent prostate biopsy, PHI was a significant predictor of biopsy outcomes, independent of other clinical variables. The AUC in discriminating PCa from non-PCa was consistently higher for PHI than tPSA in the entire cohort (0.88 vs. 0.81) as well as in patients with tPSA at 2-10 ng/ml (0.73 vs. 0.53), at 10.1-20 ng/ml (0.81 vs. 0.58), and at tPSA >20 ng/ml (0.90 vs. 0.80). The differences were statistically significant in all comparisons, P < 0.01. To detect 90% of all PCa in the cohort, 362 and 457 patients would need to be biopsied based on PHI and tPSA cutoff, respectively, a 21% reduction for PHI. Similar results were found for discriminating high-grade PCa. PHI provides added value over tPSA in discriminating PCa and high-grade PCa in patients who underwent prostate biopsy in China. © 2014 Wiley Periodicals, Inc.

  17. [PSA testing, biopsy and cancer and benign prostate hyperplasia in France].

    PubMed

    Tuppin, P; Samson, S; Fagot-Campagna, A; Lukacs, B; Alla, F; Allemand, H; Paccaud, F; Thalabard, J-C; Vicaut, E; Vidaud, M; Millat, B

    2014-07-01

    Prostate-specific antigen (PSA) testing is high in France. The aim of this study was to estimate their frequency and those of biopsy and newly diagnosed cancer (PCa) according to the presence or absence of treated benign prostatic hyperplasia (BPH). This study concerned men 40 years and older covered by the main French national health insurance scheme (73 % of all men of this age). Data were collected from the national health insurance information system (SNIIRAM). This database comprehensively records all of the outpatient prescriptions and healthcare services reimbursed. This information are linked to data collected during hospitalisations. The frequency of men without diagnosed PCa (10.9 millions) with at least one PSA test was very high in 2011 (men aged 40 years and older: 30 %, 70-74 years: 56 %, 85 years and older: 33 % and without HBP: 25 %, 41 % and 19 %). Men with treated BPH totalized 9 % of the study population, but 18 % of the men with at least one PSA test, 44 % of those with at least one prostate biopsy and 40 % of those with newly managed PCa. Over a 3-year period, excluding men with PCa, 88 % of men with BPH had at least one PSA test and 52 % had three or more PSA tests versus 52 % and 15 % for men without BPH. One year after PSA testing, men of 55-69 years with BPH more frequently underwent prostate biopsy than those without BPH (5.4 % vs 1.8 %) and presented PCa (1.9 % vs 0.9 %). PSA testing frequencies in France are very high even after exclusion of men with BPH, who can be a group with more frequent managed PCa. 4. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Clinical Utility of Quantitative Gleason Grading in Prostate Biopsies and Prostatectomy Specimens.

    PubMed

    Sauter, Guido; Steurer, Stefan; Clauditz, Till Sebastian; Krech, Till; Wittmer, Corinna; Lutz, Florian; Lennartz, Maximilian; Janssen, Tim; Hakimi, Nayira; Simon, Ronald; von Petersdorff-Campen, Mareike; Jacobsen, Frank; von Loga, Katharina; Wilczak, Waldemar; Minner, Sarah; Tsourlakis, Maria Christina; Chirico, Viktoria; Haese, Alexander; Heinzer, Hans; Beyer, Burkhard; Graefen, Markus; Michl, Uwe; Salomon, Georg; Steuber, Thomas; Budäus, Lars Henrik; Hekeler, Elena; Malsy-Mink, Julia; Kutzera, Sven; Fraune, Christoph; Göbel, Cosima; Huland, Hartwig; Schlomm, Thorsten

    2016-04-01

    Gleason grading is the strongest prognostic parameter in prostate cancer. Gleason grading is categorized as Gleason ≤ 6, 3 + 4, 4 + 3, 8, and 9-10, but there is variability within these subgroups. For example, Gleason 4 components may range from 5-45% in a Gleason 3 + 4 = 7 cancer. To assess the clinical relevance of the fractions of Gleason patterns. Prostatectomy specimens from 12823 consecutive patients and of 2971 matched preoperative biopsies for which clinical data with an annual follow-up between 2005 and 2014 were available from the Martini-Klinik database. To evaluate the utility of quantitative grading, the fraction of Gleason 3, 4, and 5 patterns seen in biopsies and prostatectomies were recorded. Gleason grade fractions were compared with prostatectomy findings and prostate-specific antigen recurrence. Our data suggest a striking utility of quantitative Gleason grading. In prostatectomy specimens, there was a continuous increase of the risk of prostate-specific antigen recurrence with increasing percentage of Gleason 4 fractions with remarkably small differences in outcome at clinically important thresholds (0% vs 5%; 40% vs 60% Gleason 4), distinguishing traditionally established prognostic groups. Also, in biopsies, the quantitative Gleason scoring identified various intermediate risk groups with respect to Gleason findings in corresponding prostatectomies. Quantitative grading may also reduce the clinical impact of interobserver variability because borderline findings such as tumors with 5%, 40%, or 60% Gleason 4 fractions and very small Gleason 5 fractions (with pivotal impact on the Gleason score) are disclaimed. Quantitative Gleason pattern data should routinely be provided in addition to Gleason score categories, both in biopsies and in prostatectomy specimens. Gleason score is the most important prognostic parameter in prostate cancer, but prone to interobserver variation. The results of our study show that morphological aspects that define

  19. Multiparametric magnetic resonance imaging predicts the presence of prostate cancer in patients with negative prostate biopsy.

    PubMed

    Lista, F; Castillo, E; Gimbernat, H; Rodríguez-Barbero, J M; Panizo, J; Angulo, J C

    2015-03-01

    To assess the ability of multiparametric prostate magnetic resonance imaging (mpMRI) to detect prostate cancer in patients with prior negative transrectal prostate biopsy (TPB). mpMRI (TSE-T2-w, DWI and DCE sequences) was performed on 1.5T (Magnetom Avanto; Siemens Healthcare Solutions) in 150 patients suspicious of prostate cancer and with negative TPB. European Society of Urogenital Radiology (ESUR) criteria were used (score 1: clinically significant disease is highly unlikely to be present; score 2: clinically significant cancer is unlikely to be present; score 3: clinically significant cancer is equivocal; score 4: clinically significant cancer is likely to be present; score 5: clinically significant cancer is highly likely to be present). PSA measurement (total and free), digital rectal examination (DRE), transrectal ultrasound (TRU) and a second TPB (at least 14 cylinders) were performed in all patients. Variables were submitted for independent blind analysis. The accuracy of each test was measured. Stepwise selection model for prediction of prostate cancer in second TPB was developed. Mean age was 66.2± 5 years (51-77), mean PSA 11.3± 9.6ng/mL (0.9-75) and mean prostatic volume 82.2±42 (20-250) cc. DRE was suspicious in 11 (7.3%) patients. The mean number of cylinders per patient sampled in second TRB was 17.6±2.7(14-22). Second TRB was positive in 28 patients (18.7%). mpMRI was positive (score 3-5) in 102 (68%), test sensibility was 92.9% and the NPV was 95.8%. The risk of prostate cancer diagnosis in second TPB is modified by: PSA velocity > 0.75 (OR 1.04 [0.99-1.08]; P=0.06), free/total ratio PSA <15% (OR 0.37 [0.13-1.05]; P=0.06), each cc. of prostate volume (OR 0.98 [0.97-1]; P=0.017) and mpMRI 3-5 (OR 7.87 [1.78-34.7]; P=0.006). Multivariate analysis reveals that mpMRI (OR 7.41 [1.65-33.28]; P=0.009) and prostatic volume (OR 0.31 [0.12-0.78]; P=0.01) are independent risk predictors of prostate cancer. According to ESUR guidelines and in patients

  20. [Critical haematuria after prostate biopsies with RIVAROXABAN. Case report].

    PubMed

    Olivier, J; Yakoubi, R; Gras, S; Van Agt, G; Delepaul, B

    2013-10-01

    Managing patients with new oral anticoagulants in perioperative period is not yet well protocolized. We report a clinical case of a critical haematuria after prostate biopsies to a patient treated with RIVAROXABAN. Monitoring and treatment of the haematuria have been difficult due to the lack of biological control and antidote for this treatment. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Definitions of terms, processes and a minimum dataset for transperineal prostate biopsies: a standardization approach of the Ginsburg Study Group for Enhanced Prostate Diagnostics.

    PubMed

    Kuru, Timur H; Wadhwa, Karan; Chang, Richard Tsung Meng; Echeverria, Lina Maria Carmona; Roethke, Matthias; Polson, Alexander; Rottenberg, Giles; Koo, Brendan; Lawrence, Edward M; Seidenader, Jonas; Gnanapragasam, Vincent; Axell, Richard; Roth, Wilfried; Warren, Anne; Doble, Andrew; Muir, Gordon; Popert, Rick; Schlemmer, Heinz-Peter; Hadaschik, Boris A; Kastner, Christof

    2013-09-01

    To define terms and processes and agree on a minimum dataset in relation to transperineal prostate biopsy procedures and enhanced prostate diagnostics. To identify the need for further evaluation and establish a collaborative research practice. A 19-member multidisciplinary panel rated 66 items for their appropriateness and their definition to be incorporated into the international databank using the Research and Development/University of California Los Angeles Appropriateness Method. The item list was developed from interviews conducted with healthcare professionals from urology, radiology, pathology and engineering. The panel agreed on 56 items that were appropriate to be incorporated into a prospective database. In total, 10 items were uncertain and were omitted. These items were within the categories: definitions (n = 2), imaging (n = 1), surgical protocols (n = 2) and histology (n = 5). The components of a minimum dataset for transperineal prostate biopsy have been defined. This provides an opportunity for multicentre collaborative data analysis and technique development. The findings of the present study will facilitate prospective studies into the application and outcome of transperineal prostate biopsies. © 2013 BJU International.

  2. The performance of PI-RADSv2 and quantitative apparent diffusion coefficient for predicting confirmatory prostate biopsy findings in patients considered for active surveillance of prostate cancer.

    PubMed

    Nougaret, Stephanie; Robertson, Nicola; Golia Pernicka, Jennifer; Molinari, Nicolas; Hötker, Andreas M; Ehdaie, Behfar; Sala, Evis; Hricak, Hedvig; Vargas, Hebert Alberto

    2017-07-01

    To assess the performance of the updated Prostate Imaging Reporting and Data System (PI-RADSv2) and the apparent diffusion coefficient (ADC) for predicting confirmatory biopsy results in patients considered for active surveillance of prostate cancer (PCA). IRB-approved, retrospective study of 371 consecutive men with clinically low-risk PCA (initial biopsy Gleason score ≤6, prostate-specific antigen <10 ng/ml, clinical stage ≤T2a) who underwent 3T-prostate MRI before confirmatory biopsy. Two independent radiologists recorded the PI-RADSv2 scores and measured the corresponding ADC values in each patient. A composite score was generated to assess the performance of combining PI-RADSv2 + ADC. PCA was upgraded on confirmatory biopsy in 107/371 (29%) patients. Inter-reader agreement was substantial (PI-RADSv2: k = 0.73; 95% CI [0.66-0.80]; ADC: r = 0.74; 95% CI [0.69-0.79]). Accuracies, sensitivities, specificities, positive predicted value and negative predicted value of PI-RADSv2 were 85, 89, 83, 68, 95 and 78, 82, 76, 58, 91% for ADC. PI-RADSv2 accuracy was significantly higher than that of ADC for predicting biopsy upgrade (p = 0.014). The combined PI-RADSv2 + ADC composite score did not perform better than PI-RADSv2 alone. Obviating biopsy in patients with PI-RADSv2 score ≤3 would have missed Gleason Score upgrade in 12/232 (5%) of patients. PI-RADSv2 was superior to ADC measurements for predicting PCA upgrading on confirmatory biopsy.

  3. Prostate biopsy

    MedlinePlus

    ... shows that you have a higher than normal prostate specific antigen (PSA) level Your provider discovers a lump or abnormality in your prostate during a digital rectal exam Normal Results Normal ...

  4. EUS-guided biopsy for the diagnosis and classification of lymphoma.

    PubMed

    Ribeiro, Afonso; Pereira, Denise; Escalón, Maricer P; Goodman, Mark; Byrne, Gerald E

    2010-04-01

    EUS-guided FNA and Tru-cut biopsy (TCB) is highly accurate in the diagnosis of lymphoma. Subclassification, however, may be difficult in low-grade non-Hodgkin lymphoma and Hodgkin lymphoma. To determine the yield of EUS-guided biopsy to classify lymphoma based on the World Health Organization classification of tumors of hematopoietic lymphoid tissues. Retrospective study. Tertiary referral center. A total of 24 patients referred for EUS-guided biopsy who had a final diagnosis of lymphoma or "highly suspicious for lymphoma." EUS-guided FNA and TCB combined with flow cytometry (FC) analysis. MAIN OUTCOMES MEASUREMENT: Lymphoma subclassification accuracy of EUS guided biopsy. Twenty-four patients were included in this study. Twenty-three patients underwent EUS-FNA, and 1 patient had only TCB. Twenty-two underwent EUS-TCB combined with FNA. EUS correctly diagnosed lymphoma in 19 out of 24 patients (79%), and subclassification was determined in 16 patients (66.6%). Flow cytometry correctly identified B-cell monoclonality in 95% (18 out of 19). In 1 patient diagnosed as having marginal-zone lymphoma by EUS-FNA/FC only, the diagnosis was changed to hairy cell leukemia after a bone marrow biopsy was obtained. EUS had a lower yield in nonlarge B-cell lymphoma (only 9 out of 15 cases [60%]) compared with large B-cell lymphoma (78%; P = .3 [Fisher exact test]). Retrospective, small number of patients. EUS-guided biopsy has a lower yield to correctly classify Hodgkin lymphoma and low-grade lymphoma compared with high-grade diffuse large B-cell lymphoma. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  5. A fatal case of hemoperitoneum after ultrasound-guided liver biopsy in a patient with intravascular large B-cell lymphoma.

    PubMed

    Aoki, Yasuhiro; Takamiya, Masataka; Satoh, Takashi; Fujita, Sachiko; Kato, Hideaki; Maeno, Yoshitaka

    2011-07-01

    An autopsy case of fatal complication of percutaneous liver biopsy targeting a rare type of large B-cell lymphoma is presented. A 79 year-old man was referred to the hematology unit of a hospital because of anemia with thrombocytopenia and hepatosplenomegaly. Results of inguinal lymph node biopsy were inconclusive. To investigate a mass lesion in the liver visualized by ultrasonography, image-guided liver biopsy was performed following platelet infusion. The patient became unresponsive 6h post procedure because of hypotension due to intraperitoneal hemorrhage of undetermined origin. Autopsy revealed hemoperitoneum but failed to identify any macroscopic intra- or extrahepatic vascular injuries. Histopathological investigation disclosed infiltration of atypical lymphocytes into the systemic organs including the lymph nodes, spleen, liver, and lungs. Prominent hemophagocytosis was also noted. The lymphoma cells were exclusively accumulated within vascular and sinusoidal structures, and diagnosed with immunohistochemistry as Asian variant of intravascular large B-cell lymphoma. Massive blood extravasation was presumed to originate directly from the markedly dilated liver sinusoids filled with erythrocytes, macrophages and tumor cells, under the condition of impaired hemostasis. Although the biopsy was thought to have been correctly performed, this case would be instructive for evaluation of the indications and risks associated with liver biopsy. 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Prostate Mechanical Imaging: A New Method For Prostate Assessment

    PubMed Central

    Weiss, Robert E; Egorov, Vladimir; Ayrapetyan, Suren; Sarvazyan, Noune; Sarvazyan, Armen

    2008-01-01

    Objectives To evaluate the ability of Prostate Mechanical Imaging (PMI) technology to provide an objective and reproducible image and to assess the prostate nodularity. Methods The PMI device developed by Artann Laboratories was evaluated in a pilot clinical study. For the 168 patients (ages 44 to 94) presented to an urologist for prostate evaluation, PMI-produced images and assessment of prostate size, shape, consistency/hardness, mobility, nodularity, and was compared with digital rectal examination (DRE) findings. The PMI and DRE results were further tested for correlation against a transrectal ultrasound of the prostate (TRUS) guided biopsy for a sub-group of 21 patients with an elevated PSA level. Results In 84% of the cases the PMI device was able to reconstruct 3-D and 2-D cross-sectional images of the prostate. The PMI System and DRE pre-tests were able to determine malignant nodules in 10 and 6 patients, respectively, of the 13 patients with biopsy-confirmed malignant inclusions. The PMI System findings were consistent with all 8 biopsy negative cases, while the DRE had 1 abnormal reading for this group. The correlation between PMI and DRE detection of palpable nodularity was 81%, as indicated by the area under the receiver operating characteristic (ROC) curve. Estimates of the prostate size provided by PMI and DRE were found to be statistically significantly correlated. Conclusions The PMI has the potential to enable a physician to obtain, examine and store a three dimensional image of the prostate based on mechanical and geometrical characteristics of the gland and its internal structures. PMID:18342178

  7. Number of positive preoperative biopsy cores is a predictor of positive surgical margins (PSM) in small prostates after robot-assisted radical prostatectomy (RARP).

    PubMed

    Tuliao, Patrick H; Koo, Kyo C; Komninos, Christos; Chang, Chien H; Choi, Young D; Chung, Byung H; Hong, Sung J; Rha, Koon H

    2015-12-01

    To determine the impact of prostate size on positive surgical margin (PSM) rates after robot-assisted radical prostatectomy (RARP) and the preoperative factors associated with PSM. In all, 1229 men underwent RARP by a single surgeon, from 2005 to August of 2013. Excluded were patients who had transurethral resection of the prostate, neoadjuvant therapy, clinically advanced cancer, and the first 200 performed cases (to reduce the effect of learning curve). Included were 815 patients who were then divided into three prostate size groups: <31 g (group 1), 31-45 g (group 2), >45 g (group 3). Multivariate analysis determined predictors of PSM and biochemical recurrence (BCR). Console time and blood loss increased with increasing prostate size. There were more high-grade tumours in group 1 (group 1 vs group 2 and group 3, 33.9% vs 25.1% and 25.6%, P = 0.003 and P = 0.005). PSM rates were higher in prostates of <45 g with preoperative PSA levels of >20 ng/dL, Gleason score ≥7, T3 tumour, and ≥3 positive biopsy cores. In group 1, preoperative stage T3 [odds ratio (OR) 3.94, P = 0.020] and ≥3 positive biopsy cores (OR 2.52, P = 0.043) were predictive of PSM, while a PSA level of >20 ng/dL predicted the occurrence of BCR (OR 5.34, P = 0.021). No preoperative factors predicted PSM or BCR for groups 2 and 3. A preoperative biopsy with ≥3 positive cores in men with small prostates predicts PSM after RARP. In small prostates with PSM, a PSA level of >20 ng/dL is a predictor of BCR. These factors should guide the choice of therapy and indicate the need for closer postoperative follow-up. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  8. The association between race and prostate cancer risk on initial biopsy in an equal access, multiethnic cohort

    PubMed Central

    Gaines, Alexis R.; Turner, Elizabeth L.; Moorman, Patricia G.; Freedland, Stephen J.; Keto, Christopher J.; McPhail, Megan E.; Grant, Delores J.; Vidal, Adriana C.

    2014-01-01

    Purpose Population-based studies have established a link between race and prostate cancer (PC) risk, but whether race predicts PC after adjusting for clinical characteristics is unclear. We investigated the association between race and risk of low- and high-grade PC in men undergoing initial prostate biopsy in an equal access medical center. Methods We conducted a retrospective record review of 887 men (48.6 % black, 51.4 % white) from the Durham Veterans Affairs Medical Center who underwent initial prostate biopsy between 2001 and 2009. Multivariable logistic regression analysis of race and biopsy outcome was conducted adjusting for age, body mass index, number of cores taken, prostate-specific antigen (PSA), and digital rectal examination findings. Multinomial logistic regression was used to test the association between black race and PC grade (Gleason <7 vs. ≥7). Results Black men were younger at biopsy (61 vs. 65 years, p <0.001) and had a higher pre-biopsy PSA (6.6 vs. 5.8 ng/ml, p = 0.001). A total of 499 men had PC on biopsy (245 low grade; 254 high grade). In multivariable analyses, black race was significantly predictive of PC overall [odds ratio 1.50, p = 0.006] and high-grade PC [relative risk ratio (RRR) 1.84, p = 0.001], but was not significantly associated with low-grade PC (RRR 1.29, p = 0.139). Conclusion In an equal access healthcare facility, black race was associated with greater risk of PC detection on initial biopsy and of high-grade PC after adjusting for clinical characteristics. Additional investigation of mechanisms linking black race and PC risk and PC aggressiveness is needed. PMID:24879044

  9. The association between race and prostate cancer risk on initial biopsy in an equal access, multiethnic cohort.

    PubMed

    Gaines, Alexis R; Turner, Elizabeth L; Moorman, Patricia G; Freedland, Stephen J; Keto, Christopher J; McPhail, Megan E; Grant, Delores J; Vidal, Adriana C; Hoyo, Cathrine

    2014-08-01

    Population-based studies have established a link between race and prostate cancer (PC) risk, but whether race predicts PC after adjusting for clinical characteristics is unclear. We investigated the association between race and risk of low- and high-grade PC in men undergoing initial prostate biopsy in an equal access medical center. We conducted a retrospective record review of 887 men (48.6 % black, 51.4 % white) from the Durham Veterans Affairs Medical Center who underwent initial prostate biopsy between 2001 and 2009. Multivariable logistic regression analysis of race and biopsy outcome was conducted adjusting for age, body mass index, number of cores taken, prostate-specific antigen (PSA), and digital rectal examination findings. Multinomial logistic regression was used to test the association between black race and PC grade (Gleason <7 vs. ≥7). Black men were younger at biopsy (61 vs. 65 years, p < 0.001) and had a higher pre-biopsy PSA (6.6 vs. 5.8 ng/ml, p = 0.001). A total of 499 men had PC on biopsy (245 low grade; 254 high grade). In multivariable analyses, black race was significantly predictive of PC overall [odds ratio 1.50, p = 0.006] and high-grade PC [relative risk ratio (RRR) 1.84, p = 0.001], but was not significantly associated with low-grade PC (RRR 1.29, p = 0.139). In an equal access healthcare facility, black race was associated with greater risk of PC detection on initial biopsy and of high-grade PC after adjusting for clinical characteristics. Additional investigation of mechanisms linking black race and PC risk and PC aggressiveness is needed.

  10. A single microfocus (5% or less) of Gleason 6 prostate cancer at biopsy--can we predict adverse pathological outcomes?

    PubMed

    Thong, Alan E; Shikanov, Sergey; Katz, Mark H; Gofrit, Ofer N; Eggener, Scott; Zagaja, Gregory P; Shalhav, Arieh L; Zorn, Kevin C

    2008-12-01

    Patients with Gleason score 6 microfocal prostate cancer, defined as 5% or less in 1 biopsy core, are often considered to have favorable disease. Few studies have addressed clinical parameters that predict pathological upgrading or up staging at radical prostatectomy. From a prospective database of 1,271 consecutive robot assisted laparoscopic prostatectomies performed from 2003 to 2008 patients with Gleason score 6 microfocal prostate cancer were identified. Adverse pathological outcome was defined as any upgrading and/or up staging on prostatectomy pathological findings. Multivariate logistic regression was used to evaluate the ability of patient age, clinical stage, the total number of biopsy cores, preoperative prostate specific antigen, prostate volume and pathological prostate specific antigen density to predict adverse pathological outcomes. A total of 192 patients with a median age of 59 years (range 42 to 73) were identified with Gleason score 6 prostate cancer involving 5% or less of 1 biopsy core, including 177 (92%) with clinical T1c disease. Mean +/- SD preoperative prostate specific antigen was 6.0 +/- 3.9 ng/ml (range 0.8 to 35). Overall 42 patients (22%) had adverse pathological outcomes, including upgrading in 35 (18%) and up staging in 16 (8%). Multivariate logistic regression revealed that age more than 65 years and pathological prostate specific antigen density greater than 0.20 ng/ml/gm were predictive of an increased risk of adverse pathological results (p = 0.0081 and 0.0169, respectively). While a microfocus of Gleason score 6 prostate cancer on biopsy is commonly considered low risk disease, there was a greater than 1/5 risk of pathological upgrading and/or up staging. Patients with Gleason score 6 microfocal prostate cancer should be counseled that they may harbor more aggressive disease, especially when pretreatment clinical risk factors are present, such as advanced age or high clinical prostate specific antigen density.

  11. Comparative Effectiveness of Frame-based, Frameless and Intraoperative MRI Guided Brain Biopsy Techniques

    PubMed Central

    Lu, Yi; Yeung, Cecil; Radmanesh, Alireza; Wiemann, Robert; Black, Peter M.; Golby, Alexandra J.

    2015-01-01

    Objective Intraoperative MRI (IoMRI) guided brain biopsy provides a real time visual feedback of the lesion that is sampled during surgery. The objective of the study is to compare the diagnostic yield and safety profiles of ioMRI needle brain biopsy with two traditional brain biopsy methods: frame-based and frameless stereotactic brain biopsies. Methods A retrospective analysis from 288 consecutive needle brain biopsies in 277 patients undergoing stereotactic brain biopsy with any of the three biopsy methods at Brigham and Women's Hospital from 2000 to 2008 was performed. Variables such as age, sex, history of radiation and previous surgery, pathology results, complications and postoperative stays were analyzed. Results Over the course of eight years, 288 brain biopsies were performed. 253 (87.8%) biopsies yielded positive diagnostic tissue. Young age (<40 years), history of brain radiation or surgery were significant negative predictors for a positive biopsy diagnostic yield. Excluding patients with prior radiation or surgeries, no significant difference in diagnostic yield was detected among the three groups, with frame-based, frameless and ioMRI guided needle biopsies yield 96.9%, 91.8% and 89.9% positive diagnostic yield, respectively. 19 biopsies (6.6%) were complicated by serious adverse events. The ioMRI-guided brain biopsy was associated with less serious adverse events and the shortest postoperative hospital stay. Conclusions Frame-based, frameless stereotactic and ioMRI guided brain needle biopsy have comparable diagnostic yield for patients with no prior treatments (either radiation or surgery). IoMRI guided brain biopsy is associated with fewer serious adverse events and shorter hospital stay. PMID:25088233

  12. Manually controlled targeted prostate biopsy with real-time fusion imaging of multiparametric magnetic resonance imaging and transrectal ultrasound: an early experience.

    PubMed

    Shoji, Sunao; Hiraiwa, Shinichiro; Endo, Jun; Hashida, Kazunobu; Tomonaga, Tetsuro; Nakano, Mayura; Sugiyama, Tomoko; Tajiri, Takuma; Terachi, Toshiro; Uchida, Toyoaki

    2015-02-01

    To report our early experience with manually controlled targeted biopsy with real-time multiparametric magnetic resonance imaging and transrectal ultrasound fusion images for the diagnosis of prostate cancer. A total of 20 consecutive patients suspicious of prostate cancer at the multiparametric magnetic resonance imaging scan were recruited prospectively. Targeted biopsies were carried out for each cancer-suspicious lesion, and 12 systematic biopsies using the BioJet system. Pathological findings of targeted and systematic biopsies were analyzed. The median age of the patients was 70 years (range 52-83 years). The median preoperative prostate-specific antigen value was 7.4 ng/mL (range 3.54-19.9 ng/mL). Median preoperative prostate volume was 38 mL (range 24-68 mL). The number of cancer-detected cases was 14 (70%). The median Gleason score was 6.5 (range 6-8). Cancer-detected rates of the systematic and targeted biopsy cores were 6.7 and 31.8%, respectively (P < 0.0001). In six patients who underwent radical prostatectomy, the geographic locations and pathological grades of clinically significant cancers and index lesions corresponded to the pathological results of the targeted biopsies. Prostate cancers detected by targeted biopsies with manually controlled targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound fusion imaging have significantly higher grades and longer length compared with those detected by systematic biopsies. Further studies and comparison with the pathological findings of whole-gland specimens have the potential to determine the role of this biopsy methodology in patients selected for focal therapy and those under active surveillance. © 2014 The Japanese Urological Association.

  13. A 'One Stop' Prostate Clinic for rural and remote men: a report on the first 200 patients.

    PubMed

    McCombie, Steve P; Hawks, Cynthia; Emery, Jon D; Hayne, Dickon

    2015-10-01

    To report on the structure and outcomes of a new 'One Stop' Prostate Clinic (OSPC) designed specifically for rural and remote men. Prospective cohort study of the first 200 rural or remote men to access a new OSPC at a public tertiary-level hospital in Western Australia between August 2011 and August 2014. Men attended for urological assessment, and proceeded to same-day transrectal ultrasonography-guided prostate biopsies, if appropriate. Referral criteria were either two abnormal age-related prostate-specific antigen (PSA) levels in the absence of urinary tract infection (UTI), or an abnormal digital rectal examination (DRE) regardless of PSA level. The median (range) distance travelled was 1545 (56-3229) km and median (range) time from referral to assessment was 33 (2-165) days. The median (range) age was 62 (38-85) years, PSA level was 6.7 (0.5-360) ng/mL and 39% (78/200) had a suspicious DRE. In all, 92% (184/200) of men proceeded to prostate biopsies, and 60% (111/184) of these men were diagnosed with prostate cancer. Our complication rate was 3.5% (6/172). Radical prostatectomy (46/111), active surveillance (28/111) and external beam radiation therapy (26/111) were the commonest subsequent treatment methods. A $1045 (Australian dollars) cost-saving per person was estimated based on the reduced need for travel with the OSPC model. The OSPC is an effective and efficient model for assessing men suspected of having prostate cancer living in rural and remote areas of Western Australia, and this model may be applicable to other areas. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  14. Prostate cancer: cryotherapy.

    PubMed

    Shinohara, Katsuto

    2003-11-01

    The incidence of prostate cancer has more than doubled in the last 10 years, and 220,900 new cases will be detected in 2003. This increase is due in large part to increased use of prostate-specific antigen (PSA)-based screening, transrectal ultrasonography, and random biopsy of the prostate. The treatment of prostate cancer, however, remains controversial, and no consensus has been established as to what constitutes appropriate treatment for any stage of disease, especially for localized cancers. Radical prostatectomy, radiation therapy, or watchful waiting all have their advocates, and the risks and benefits of these approaches are discussed frequently. Skepticism about conventional treatments has stimulated patients and physicians to search for alternatives that are effective and associated with limited morbidity. Technologic developments have rekindled interest in cryotherapy as a viable alternative to other, more conventional localized therapies. Given the relative paucity of alternatives for patients who experience biochemical progression after radiotherapy, cryosurgery also may prove to be a good alternative for those patients whose tumors appear to remain localized despite progression. In addition, it appears that cryosurgery will play an increased role in the future management of prostate cancer.

  15. Comparison of Ultrasonography-Guided Central Venous Catheterization Between Adult and Pediatric Populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tercan, Fahri; Oguzkurt, Levent; Ozkan, Ugur

    2008-05-15

    The purpose of this study was to compare the technical success and complication rates of ultrasonography-guided central venous catheterization between adult and pediatric patients which have not been reported previously. In a 4-year period, 859 ultrasonography-guided central vein catheterizations in 688 adult patients and 247 catheterizations in 156 pediatric patients were retrospectively evaluated. Mean age was 56.3 years (range, 18 to 95 years) for adults and 3.3 years (range, 0.1 to 16.3 years) for children. The preferred catheterization site was internal jugular vein in 97% of adults and 85% of children. The technical success rate, mean number of punctures, andmore » rate of single wall puncture were 99.4%, 1.04 (range, 1-3), and 83% for adults and 90.3%, 1.25 (range, 1-5), and 49% for children, respectively. All the differences were statistically significant (p < 0.05). Complication rates were 2.3% and 2.4% for adults and children, respectively (p > 0.05). Major complications such as pneumothorax and hemothorax were not seen in any group. In conclusion, ultrasonography-guided central venous catheterization has a high technical success rate, lower puncture attempt rate, and higher single wall puncture rate in adults compared to children. Complication rates are comparable in the two groups.« less

  16. Use of Age and Medical Comorbidity to Assess Long-term Other-cause Mortality Risk in a Cohort of Men Undergoing Prostate Biopsy at an Academic Medical Center.

    PubMed

    Kominsky, Hal D; Bashline, Michael; Eun, Daniel; Pontari, Michel A; Mydlo, Jack H; Reese, Adam C

    2017-02-01

    To assess life expectancy and biopsy outcomes in men undergoing prostate biopsy at an academic medical center. We analyzed men who underwent prostate biopsy at our medical center between July 2012 and June 2014. Long-term other-cause mortality risk was determined using survival tables. Indications for biopsy and biopsy outcomes were assessed, and compared among men with varying mortality risks. A total of 417 men underwent prostate biopsy, in whom 14-year other-cause mortality risk ranged from 9% to 74%. One hundred ninety-three men (46.3%) were considered low-mortality risk (<40% risk of 14-year mortality), 131 (31.4%) intermediate risk (41%-55% 14-year mortality), and 93 (22.3%) high risk (>55% 14-year mortality). Of the 417 patients who underwent biopsy, 149 (35.7%) were found to have prostate cancer. There was no significant difference in the rate of positive biopsies (P = .72), distribution of Gleason scores (P = .60), or percentage of positive biopsy cores (P = .74) between mortality risk groups. However, by UCSF Cancer of the Prostate Risk Assessment score, there was significant trend toward higher-risk prostate cancer in men with intermediate and high-mortality risk (P = .04). In this analysis, a large number of men with limited life expectancies underwent prostate biopsy. The majority of these men had negative biopsies or low-risk cancers, suggesting that they were unlikely to benefit from biopsy. To avoid potentially unnecessary prostate biopsies, the practitioner must give serious consideration to a patient's age and medical comorbidities before making a recommendation as to whether biopsy should be performed. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. The prognostic value of reactive stroma on prostate needle biopsy: a population-based study.

    PubMed

    Saeter, Thorstein; Vlatkovic, Ljiljana; Waaler, Gudmund; Servoll, Einar; Nesland, Jahn M; Axcrona, Karol; Axcrona, Ulrika

    2015-05-01

    Reactive tumor stroma has been shown to play an active role in prostatic carcinogenesis. A grading system for reactive stroma in prostate cancer (PC) has recently been established and found to predict biochemical recurrence and prostate cancer-specific mortality (PCSM) in prostatectomized patients. To the best of our knowledge, there has been no study investigating the prognostic value of reactive stromal grading (RSG) with regard to PCSM when evaluated in diagnostic prostate needle biopsies. A population-based study on 318 patients, encompassing all cases of PC diagnosed by needle biopsies and without evidence of systemic metastasis at the time of diagnosis in Aust-Agder County in the period 1991-1999. Patients were identified by cross-referencing the Cancer Registry of Norway. Clinical data were obtained by review of medical charts. The endpoint was PCSM. RSG was evaluated on haematoxylin and eosin stained sections according to previously described criteria; grade 0, 0-5% reactive stroma; grade 1, 6-15%; grade 2, 16-50%; grade 3, 51-100%. RSG could be evaluated in 278 patients. The median follow- up time was 110 months (interquartile range: 51-171). The 10-year PC - specific survival rate for RSGs of 0, 1, 2, and 3 was 96%, 81%, 69%, and 63%, respectively (P < 0.005). RSG remained independently associated with PCSM in a multivariate Cox regression analysis adjusting for prostate-specific antigen level, clinical stage, Gleason score, and mode of treatment. The concordance index of the multivariate model was 0.814 CONCLUSIONS: Our study demonstrates that RSG in diagnostic prostate needle biopsies predicts PCSM independently of other evaluable prognostic factors. Hence, RSG could be used in addition to traditional prognostic factors for prognostication and treatment stratification of PC patients. © 2015 Wiley Periodicals, Inc.

  18. [Use of MRI before biopsy in diagnosis of prostate cancer: Single-operator study].

    PubMed

    Bassard, S; Mege, J-L

    2015-12-01

    The diagnostic for prostate cancer is changing. To improve the detection of this cancer, urologists expect a lot from the contribution of magnetic resonance imaging (MRI). What is the role of this imaging in prostate cancer detection? This is a retrospective study, from 2011 to 2013, mono-centric and single-operator. Of the 464 needle biopsy of the prostate (BP), we excluded those with PSA>20 ng/mL or digital rectal examination (DRE)>T3. The remaining 430 BP were submitted or not to a 1.5 tesla MRI with pelvic antenna. The primary aim is the overall detection of prostate cancer. Secondary aim was the detection rate during the first series of BP and repeat BP, between the two groups in the MRI group. MRI and MRI without populations are comparable for age (63.3 vs 64.6), PSA (6.10 vs 6.13), DRE>T1c, prostate volume (55.4 cm(3) vs 51.7 cm(3)). There is no significant difference in overall detection between the two groups (P=0.12). There is no significant difference in cancer detection between the first BP (P=0.13) and the repeat BP (P=0.07). There is a significant difference in the early detection of BP MRI group (P=0.03) but not for the BP repeat MRI group (P=0.07). For 108 BP iterative MRI group, there were 67 BP targeted "mentally" with MRI: 18 cancers were detected, making a 25% detection rate. This study helps to highlight the value of MRI in the early rounds of BP but we can ask the value of this imaging during repeat biopsies. Targeted biopsies "mentally" do not have the expected detection sensitivity and seems to require a three-dimensional reconstruction to be more effective. 5. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. PSA velocity does not aid the detection of prostate cancer in men with a prior negative biopsy: data from the European Randomized Study of Prostate Cancer Screening in Göteborg, Sweden and Rotterdam, Netherlands

    PubMed Central

    Vickers, Andrew J.; Wolters, Tineke; Savage, Caroline J.; Cronin, Angel M.; O’Brien, M. Frank; Roobol, Monique J.; Aus, Gunnar; Scardino, Peter T.; Hugosson, Jonas; Schröder, Fritz H.; Lilja, Hans

    2012-01-01

    Purpose Prostate specific antigen (PSA) velocity has been proposed as a marker to aid detection of prostate cancer. We sought to determine whether PSA velocity could predict the results of repeat biopsy in men with persistently elevated PSA after initial negative biopsy. Materials and Methods We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer (ERSPC), and who had one or more subsequent prostate biopsies after an initial negative finding. We evaluated whether PSA velocity improved predictive accuracy beyond that of PSA alone. Results There were a total of 2579 repeat biopsies, of which 363 (14%) were positive for prostate cancer, and 44 (1.7%) were high grade (Gleason score ≥7). Although PSA velocity was statistically associated with cancer risk (p<0.001), it had very low predictive accuracy (area-under-the-curve [AUC] of 0.55). There was some evidence that PSA velocity improved AUC compared to PSA for high grade cancer. However, the small increase in risk associated with high PSA velocity – from 1.7 % to 2.8% as velocity increased from 0 to 1 ng / ml / year - is of questionable clinical relevance. Conclusions Men with a prior negative biopsy have a lower risk for prostate cancer at subsequent biopsies, with high grade disease particularly rare. We found little evidence to support the use of PSA velocity to aid decisions about repeat biopsy for prostate cancer. PMID:20643434

  20. Prospective Quality of Life in Men Choosing Active Surveillance Compared to Those Biopsied but not Diagnosed with Prostate Cancer.

    PubMed

    Pham, Khanh N; Cullen, Jennifer; Hurwitz, Lauren M; Wolff, Erika M; Levie, Katherine E; Odem-Davis, Katherine; Banerji, John S; Rosner, Inger L; Brand, Timothy C; L'Esperance, James O; Sterbis, Joseph R; Porter, Christopher R

    2016-08-01

    Active surveillance is an important alternative to definitive therapy for men with low risk prostate cancer. However, the impact of active surveillance on health related quality of life compared to that in men without cancer remains unknown. In this study we evaluated health related quality of life outcomes in men on active surveillance compared to men followed after negative prostate needle biopsy. A prospective study was conducted on men who were enrolled into the Center for Prostate Disease Research Multicenter National Database and underwent prostate needle biopsy for suspicion of prostate cancer between 2007 and 2014. Health related quality of life was assessed at biopsy (baseline) and annually for up to 3 years using SF-36 and EPIC questionnaires. Health related quality of life scores were modeled using generalized estimating equations, adjusting for baseline health related quality of life, and demographic and clinical characteristics. Of the 1,204 men who met the initial eligibility criteria 420 had a negative prostate needle biopsy (noncancer comparison group). Among the 411 men diagnosed with low risk prostate cancer 89 were on active surveillance. Longitudinal analysis revealed that for most health related quality of life subscales there were no significant differences between the groups in adjusted health related quality of life score trends over time. In this study most health related quality of life outcomes in patients with low risk prostate cancer on active surveillance did not differ significantly from those of men without prostate cancer. A comparison group of men with a similar risk of prostate cancer detection is critical to clarify the psychological and physical impact of active surveillance. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Percent free prostate-specific antigen is effective to predict prostate biopsy outcome in Chinese men with prostate-specific antigen between 10.1 and 20.0 ng ml−1

    PubMed Central

    Chen, Rui; Zhou, Li-Qun; Cai, Xiao-Bing; Xie, Li-Ping; Huang, Yi-Ran; He, Da-Lin; Gao, Xu; Xu, Chuan-Liang; Ding, Qiang; Wei, Qiang; Yin, Chang-Jun; Ren, Shan-Cheng; Wang, Fu-Bo; Tian, Ye; Sun, Zhong-Quan; Fu, Qiang; Ma, Lu-Lin; Zheng, Jun-Hua; Ye, Zhang-Qun; Ye, Ding-Wei; Xu, Dan-Feng; Hou, Jian-Quan; Xu, Ke-Xin; Yuan, Jian-Lin; Gao, Xin; Liu, Chun-Xiao; Pan, Tie-Jun; Sun, Ying-Hao

    2015-01-01

    Percent free prostatic-specific antigen (%fPSA) has been introduced as a tool to avoid unnecessary biopsies in patients with a serum PSA level of 4.0–10.0 ng ml−1, however, it remains controversial whether %fPSA is effective in PSA range of 10.1–20.0 ng ml−1 in both Chinese and Western population. In this study, the diagnostic performance of %fPSA and serum PSA in predicting prostate cancer (PCa) and high-grade PCa (HGPCa) was analyzed in a multi-center biopsy cohort of 5915 consecutive Chinese patients who underwent prostate biopsy in 22 hospitals across China from January 1, 2010 to December 31, 2013. The indication for biopsy was PSA>4.0 ng ml−1 or/and suspicious digital rectal examination. Total and free serum PSA determinations were performed by three types of electrochemiluminescence immunoassays with recalibration to the World Health Organization standards. The diagnostics accuracy of PSA, %fPSA and %fPSA in combination with PSA (%fPSA + PSA) was determined by the area under the receivers operating characteristic curve (AUC). %fPSA was more effective than PSA in men aged ≥60 years old. The AUC was 0.584 and 0.635 in men aged ≥60 years old with a PSA of 4.0–10.0 ng ml−1 and 10.1–20.0 ng ml−1, respectively. The AUC of %fPSA was superior to that of PSA in predicting HGPCa in patients ≥60 years old in these two PSA range. Our results indicated that %fPSA is both statistically effective and clinical applicable to predict prostate biopsy outcome in Chinese patients aged ≥60 years old with a PSA of 4.0–10.0 ng ml−1 and 10.1–20.0 ng ml−1. PMID:25926603

  2. Percent free prostate-specific antigen is effective to predict prostate biopsy outcome in Chinese men with prostate-specific antigen between 10.1 and 20.0 ng ml(-1).

    PubMed

    Chen, Rui; Zhou, Li-Qun; Cai, Xiao-Bing; Xie, Li-Ping; Huang, Yi-Ran; He, Da-Lin; Gao, Xu; Xu, Chuan-Liang; Ding, Qiang; Wei, Qiang; Yin, Chang-Jun; Ren, Shan-Cheng; Wang, Fu-Bo; Tian, Ye; Sun, Zhong-Quan; Fu, Qiang; Ma, Lu-Lin; Zheng, Jun-Hua; Ye, Zhang-Qun; Ye, Ding-Wei; Xu, Dan-Feng; Hou, Jian-Quan; Xu, Ke-Xin; Yuan, Jian-Lin; Gao, Xin; Liu, Chun-Xiao; Pan, Tie-Jun; Sun, Ying-Hao

    2015-01-01

    Percent free prostatic-specific antigen (%fPSA) has been introduced as a tool to avoid unnecessary biopsies in patients with a serum PSA level of 4.0-10.0 ng ml-1 , however, it remains controversial whether %fPSA is effective in PSA range of 10.1-20.0 ng ml-1 in both Chinese and Western population. In this study, the diagnostic performance of %fPSA and serum PSA in predicting prostate cancer (PCa) and high-grade PCa (HGPCa) was analyzed in a multi-center biopsy cohort of 5915 consecutive Chinese patients who underwent prostate biopsy in 22 hospitals across China from January 1, 2010 to December 31, 2013. The indication for biopsy was PSA>4.0 ng ml-1 or/and suspicious digital rectal examination. Total and free serum PSA determinations were performed by three types of electrochemiluminescence immunoassays with recalibration to the World Health Organization standards. The diagnostics accuracy of PSA, %fPSA and %fPSA in combination with PSA (%fPSA + PSA) was determined by the area under the receivers operating characteristic curve (AUC). %fPSA was more effective than PSA in men aged ≥60 years old. The AUC was 0.584 and 0.635 in men aged ≥60 years old with a PSA of 4.0-10.0 ng ml-1 and 10.1-20.0 ng ml-1 , respectively. The AUC of %fPSA was superior to that of PSA in predicting HGPCa in patients ≥60 years old in these two PSA range. Our results indicated that %fPSA is both statistically effective and clinical applicable to predict prostate biopsy outcome in Chinese patients aged ≥60 years old with a PSA of 4.0-10.0 ng ml-1 and 10.1-20.0 ng ml-1 .

  3. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    PubMed

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  4. Three-dimensional ultrasound imaging of the prostate

    NASA Astrophysics Data System (ADS)

    Fenster, Aaron; Downey, Donal B.

    1999-05-01

    Ultrasonography, a widely used imaging modality for the diagnosis and staging of many diseases, is an important cost- effective technique, however, technical improvements are necessary to realize its full potential. Two-dimensional viewing of 3D anatomy, using conventional ultrasonography, limits our ability to quantify and visualize most diseases, causing, in part, the reported variability in diagnosis and ultrasound guided therapy and surgery. This occurs because conventional ultrasound images are 2D, yet the anatomy is 3D; hence the diagnostician must integrate multiple images in his mind. This practice is inefficient, and may lead to operator variability and incorrect diagnoses. In addition, the 2D ultrasound image represents a single thin plane at some arbitrary angle in the body. It is difficult to localize and reproduce the image plane subsequently, making conventional ultrasonography unsatisfactory for follow-up studies and for monitoring therapy. Our efforts have focused on overcoming these deficiencies by developing 3D ultrasound imaging techniques that can acquire B-mode, color Doppler and power Doppler images. An inexpensive desktop computer is used to reconstruct the information in 3D, and then is also used for interactive viewing of the 3D images. We have used 3D ultrasound images for the diagnosis of prostate cancer, carotid disease, breast cancer and liver disease and for applications in obstetrics and gynecology. In addition, we have also used 3D ultrasonography for image-guided minimally invasive therapeutic applications of the prostate such as cryotherapy and brachytherapy.

  5. Gleason 6 prostate cancer in one or two biopsy cores can harbor more aggressive disease.

    PubMed

    Katz, Mark H; Shikanov, Sergey; Sun, Maxine; Abdollah, Firas; Budaeus, Lars; Gong, Edward M; Eggener, Scott E; Steinberg, Gary D; Zagaja, Gregory P; Shalhav, Arieh L; Karakiewicz, Pierre I; Zorn, Kevin C

    2011-04-01

    Patients with Gleason (GL) 6 prostate cancer in one or two biopsy cores can be upgraded and/or upstaged at the time of surgery, which may adversely impact long-term outcome. A novel model for prediction of adverse pathologic outcomes was developed using preoperative characteristics. Between 2003 and 2007, 1159 patients underwent robot-assisted radical prostatectomy (RARP) at our institution. GL 6 prostate cancer in one or two biopsy cores was identified in 416 (36%) patients. Logistic regression analyses were used to assess the rate of GL ≥7 and/or extraprostatic extension at RARP. Covariates consisted of age, body mass index (BMI), number of positive cores, greatest percent of cancer in a core (GPC), clinical stage, and preoperative prostate-specific antigen (PSA) level. After backward variable selection, the developed model was internally validated using the area under the curve and subjected to methods of calibration. Respectively, 278 (67%) and 138 (33%) patients had one or two positive biopsy cores. At RARP, 90 (22%) patients were upgraded to GL ≥7 and 37 (9%) had extraprostatic extension. The novel model relied on age, BMI, preoperative PSA level, and GPC for prediction of adverse pathologic outcomes and was 69% accurate. Calibration plot revealed a virtually perfect relationship between predicted and observed probabilities. In patients with GL 6 prostate cancer in one or two biopsy cores, 25% have more ominous pathology at RARP. The model provides an individual assessment of adverse outcomes at surgery. Consequently, it may be considered when counseling patients regarding their management options.

  6. Comparative Effectiveness of Targeted Prostate Biopsy Using Magnetic Resonance Imaging Ultrasound Fusion Software and Visual Targeting: a Prospective Study.

    PubMed

    Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar

    2016-09-01

    We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance

  7. Cost-effectiveness of a new urinary biomarker-based risk score compared to standard of care in prostate cancer diagnostics - a decision analytical model.

    PubMed

    Dijkstra, Siebren; Govers, Tim M; Hendriks, Rianne J; Schalken, Jack A; Van Criekinge, Wim; Van Neste, Leander; Grutters, Janneke P C; Sedelaar, John P Michiel; van Oort, Inge M

    2017-11-01

    To assess the cost-effectiveness of a new urinary biomarker-based risk score (SelectMDx; MDxHealth, Inc., Irvine, CA, USA) to identify patients for transrectal ultrasonography (TRUS)-guided biopsy and to compare this with the current standard of care (SOC), using only prostate-specific antigen (PSA) to select for TRUS-guided biopsy. A decision tree and Markov model were developed to evaluate the cost-effectiveness of SelectMDx as a reflex test vs SOC in men with a PSA level of >3 ng/mL. Transition probabilities, utilities and costs were derived from the literature and expert opinion. Cost-effectiveness was expressed in quality-adjusted life years (QALYs) and healthcare costs of both diagnostic strategies, simulating the course of patients over a time horizon representing 18 years. Deterministic sensitivity analyses were performed to address uncertainty in assumptions. A diagnostic strategy including SelectMDx with a cut-off chosen at a sensitivity of 95.7% for high-grade prostate cancer resulted in savings of €128 and a gain of 0.025 QALY per patient compared to the SOC strategy. The sensitivity analyses showed that the disutility assigned to active surveillance had a high impact on the QALYs gained and the disutility attributed to TRUS-guided biopsy only slightly influenced the outcome of the model. Based on the currently available evidence, the reduction of over diagnosis and overtreatment due to the use of the SelectMDx test in men with PSA levels of >3 ng/mL may lead to a reduction in total costs per patient and a gain in QALYs. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  8. Use of individual containers for prostate biopsy samples: Do we gain diagnostic performance?

    PubMed

    Panach-Navarrete, J; García-Morata, F; Valls-González, L; Martínez-Jabaloyas, J M

    2016-05-01

    Prostate cores from transrectal biopsies are usually sent in separate vials for pathological processing. Although this is a common practice, there are controversial studies on its usefulness. We wanted to compare the rate of prostate cancer diagnosis between processing samples in 2 containers and processing them in individual containers to see if there are differences. Our secondary objective was to check the rate of diagnosis of various tumour subtypes in each of the 2 groups. A retrospective observational study was conducted of 2,601 cases of prostate biopsies. Ten cores were extracted in each biopsy. We divided the sample into 2 groups: biopsies sent in 2 containers to the department of pathology (left and right lobes) or sent in 10 (one for each cylinder), according to the different criteria used in our centre in the past. We then classified the cases according to the absence of neoplasia, insignificant tumour (involvement of just 1 cylinder, <5%, Gleason score<7), Gleason 6 or Gleason≥7. A bivariate statistical analysis was performed using the chi-squared test. A total of 1,777 participants were included in the 2-container group, and 824 were included in the 10-container group. We diagnosed a rate of 32.4% of cancers in the 2-container group and 40% in the 10-container group, a difference that was statistically significant (P<.001). The insignificant carcinomas were diagnosed more often in the 2-container group than in the 10-container group (6.4% vs. 4.3%, respectively; P=.03). Samples with a Gleason score of 6 were diagnosed more often in the 10-container group than in the 2-container group (11.9% vs. 8.1%, respectively; P=.002). The same occurred with the Gleason score≥7 (23.8% in the 10-container group vs. 17.9% in the 2-container group; P<.001). We diagnosed more prostate cancers when sending biopsied cores in individual containers. Once the procedure was conducted, we also observed in our series a reduction in the diagnoses of insignificant carcinoma

  9. CT-Guided Percutaneous Biopsy of Intrathoracic Lesions

    PubMed Central

    Lal, Hira; Nath, Alok; Borah, Samudra

    2012-01-01

    Percutaneous CT-guided needle biopsy of mediastinal and pulmonary lesions is a minimally invasive approach for obtaining tissue for histopathological examination. Although it is a widely accepted procedure with relatively few complications, precise planning and detailed knowledge of various aspects of the biopsy procedure is mandatory to avert complications. In this pictorial review, we reviewed important anatomical approaches, technical aspects of the procedure, and its associated complications. PMID:22438689

  10. Open-source image registration for MRI-TRUS fusion-guided prostate interventions.

    PubMed

    Fedorov, Andriy; Khallaghi, Siavash; Sánchez, C Antonio; Lasso, Andras; Fels, Sidney; Tuncali, Kemal; Sugar, Emily Neubauer; Kapur, Tina; Zhang, Chenxi; Wells, William; Nguyen, Paul L; Abolmaesumi, Purang; Tempany, Clare

    2015-06-01

    We propose two software tools for non-rigid registration of MRI and transrectal ultrasound (TRUS) images of the prostate. Our ultimate goal is to develop an open-source solution to support MRI-TRUS fusion image guidance of prostate interventions, such as targeted biopsy for prostate cancer detection and focal therapy. It is widely hypothesized that image registration is an essential component in such systems. The two non-rigid registration methods are: (1) a deformable registration of the prostate segmentation distance maps with B-spline regularization and (2) a finite element-based deformable registration of the segmentation surfaces in the presence of partial data. We evaluate the methods retrospectively using clinical patient image data collected during standard clinical procedures. Computation time and Target Registration Error (TRE) calculated at the expert-identified anatomical landmarks were used as quantitative measures for the evaluation. The presented image registration tools were capable of completing deformable registration computation within 5 min. Average TRE was approximately 3 mm for both methods, which is comparable with the slice thickness in our MRI data. Both tools are available under nonrestrictive open-source license. We release open-source tools that may be used for registration during MRI-TRUS-guided prostate interventions. Our tools implement novel registration approaches and produce acceptable registration results. We believe these tools will lower the barriers in development and deployment of interventional research solutions and facilitate comparison with similar tools.

  11. Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.

    PubMed

    Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason

    2017-05-01

    To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.

  12. Cell type specific gene expression analysis of prostate needle biopsies resolves tumor tissue heterogeneity

    PubMed Central

    Krönig, Malte; Walter, Max; Drendel, Vanessa; Werner, Martin; Jilg, Cordula A.; Richter, Andreas S.; Backofen, Rolf; McGarry, David; Follo, Marie; Schultze-Seemann, Wolfgang; Schüle, Roland

    2015-01-01

    A lack of cell surface markers for the specific identification, isolation and subsequent analysis of living prostate tumor cells hampers progress in the field. Specific characterization of tumor cells and their microenvironment in a multi-parameter molecular assay could significantly improve prognostic accuracy for the heterogeneous prostate tumor tissue. Novel functionalized gold-nano particles allow fluorescence-based detection of absolute mRNA expression levels in living cells by fluorescent activated flow cytometry (FACS). We use of this technique to separate prostate tumor and benign cells in human prostate needle biopsies based on the expression levels of the tumor marker alpha-methylacyl-CoA racemase (AMACR). We combined RNA and protein detection of living cells by FACS to gate for epithelial cell adhesion molecule (EPCAM) positive tumor and benign cells, EPCAM/CD45 double negative mesenchymal cells and CD45 positive infiltrating lymphocytes. EPCAM positive epithelial cells were further sub-gated into AMACR high and low expressing cells. Two hundred cells from each population and several biopsies from the same patient were analyzed using a multiplexed gene expression profile to generate a cell type resolved profile of the specimen. This technique provides the basis for the clinical evaluation of cell type resolved gene expression profiles as pre-therapeutic prognostic markers for prostate cancer. PMID:25514598

  13. Can Prostate-Specific Antigen Kinetics before Prostate Biopsy Predict the Malignant Potential of Prostate Cancer?

    PubMed

    Kim, Sang Jin; Jeong, Tae Yoong; Yoo, Dae Seon; Park, Jinsung; Cho, Seok; Kang, Seok Ho; Lee, Sang Hyub; Jeon, Seung Hyun; Lee, Tchun Yong; Park, Sung Yul

    2015-11-01

    To predict the malignant potential of prostate cancer (PCa) according to prostate-specific antigen velocity (PSAV), PSA density (PSAD), free/total PSA ratio (%fPSA), and digital rectal examination (DRE). From January 2009 to December 2012, 548 adult male patients were diagnosed with PCa by prostate biopsy at four hospitals in Korea. We retrospectively analyzed 155 adult male patients with an initial PSA level≤10 ng/mL and whose PSA levels had been checked more than two times at least 6 months before they had been diagnosed with PCa, with test intervals of more than 3 months. Patients with a urinary tract infection, and patients who had previously undergone cystoscopy or surgery of the prostate were excluded. We separated patients into two groups according to Gleason sum [Gleason sum≤7 (n=134) or Gleason sum≥8 (n=21)] and the presence of extracapsular invasion [organ confined (n=129) or extracapsular invasion (n=26)]. Differences between the groups were compared. The group with a Gleason sum≥8 or extracapsular invasion of PCa showed high PSAV and significantly lower %fPSA. There were no significant differences in PSAD and the presence of an abnormality on DRE between two groups. In PCa patients treated with other therapies besides prostatectomy, a high PSA velocity and a low %fPSA may predict high grade PCa with a Gleason sum≥8 or the presence of extracapsular invasion.

  14. Regular transition zone biopsy during active surveillance for prostate cancer may improve detection of pathological progression.

    PubMed

    Wong, Lih-Ming; Toi, Ants; Van der Kwast, Theodorus; Trottier, Greg; Alibhai, Shabbir M H; Timilshina, Narhari; Evans, Andrew; Zlotta, Alexandre; Fleshner, Neil; Finelli, Antonio

    2014-10-01

    We investigated the frequency of cancer and pathological progression in transition zone biopsies in men undergoing multiple rebiopsies while on active surveillance. Eligibility criteria of the active surveillance prostate cancer database (1997 to 2012) at our tertiary center includes prostate specific antigen 10 ng/ml or less, cT2 or less, no Gleason grade 4 or 5, 3 or fewer positive cores, no core with greater than 50% involvement, patient age 75 years or less and 1 or more biopsies after initial diagnostic biopsy. We excluded from analysis men with fewer than 10 cores at diagnostic biopsy and/or confirmatory biopsy greater than 24 months after diagnostic biopsy. Multiparametric magnetic resonance imaging was performed selectively to investigate incongruity between prostate specific antigen and biopsy findings. Pathological progression was defined by grade and/or volume (greater than 50% of core involved). Transition zone progression was subdivided into exclusively transition zone and combined transition zone (transition and peripheral zones). A multivariate Cox proportional hazards model was used to determine predictors of transition zone progression. A total of 392 men were considered in analysis. Median followup was 45.5 months. At each biopsy during active surveillance (confirmatory biopsy to biopsy 5+) there were transition zone positive cores in 18.6% to 26.7% of cases, all transition zone progression in 5.9% to 11.1% and exclusively transition zone progression in 2.7% to 6.7%. Volume related progression was noted more frequently than grade related progression (24 vs 9 cases). Predictors of only transition zone progression were the maximum percent in a single core (HR 1.99, 95% CI 1.30-3.04, p = 0.002) and cancer on magnetic resonance imaging (HR 3.19, 95% CI 1.23-8.27, p = 0.02). Across multiple active surveillance biopsies 2.7% to 6.7% of men had only transition zone progression. We recommend that transition zone biopsy be considered in all men at

  15. Interstitial assessment of aggressive prostate cancer by physio-chemical photoacoustics: an ex vivo study with intact human prostates.

    PubMed

    Huang, Shengsong; Qin, Yu; Chen, Yingna; Pan, Jing; Xu, Chengdang; Wu, Denglong; Chao, Wan-Yu; Wei, John T; Tomlins, Scott A; Wang, Xueding; Brian Fowlkes, J; Carson, Paul L; Cheng, Qian; Xu, Guan

    2018-06-23

    Transrectal ultrasound (TRUS) guided biopsy is the standard procedure for evaluating the presence and aggressiveness of prostate cancer. TRUS biopsy involves tissue removal, and suffers from low core yield as well as high false negative rate. A less invasive and more accurate diagnostic procedure for prostate cancer is therefore highly desired. Combining the optical sensitivity and ultrasonic resolution to resolve the spatial distribution of the major molecular components in tissue, photoacoustic (PA) technology could be an alternative approach for the diagnosis of prostate cancer. The purpose of this study is to examine the feasibility of identifying aggressive prostate cancer using interstitial PA measurements. 17 patients with pre-biopsy magnetic resonance imaging (MRI), TRUS biopsies and planned prostatectomies were enrolled in this study. The interstitial PA measurements were achieved using our recently developed needle PA probe, which was inserted into the ex vivo prostates in the fashion of a biopsy needle. A total of 70 interstitial PA measurements were acquired. The PA measurements were quantified by a previously established PA physio-chemical analysis (PAPCA) method. The histology has confirmed the nonaggressive and aggressive cancerous conditions at the insertion locations. The diagnostic accuracy was also compared to that provided by the pre-biopsy MRI. The quantitative study shows significant differences between the individual parameters of the nonaggressive and the aggressive cancerous regions (p<0.005). Multivariate analysis of the quantitative features achieved a diagnostic accuracy of 78.6% for differentiating nonaggressive and aggressive prostate cancer tissues CONCLUSIONS: The proposed procedure has shown promises in the diagnosis of aggressive prostate cancer. This article is protected by copyright. All rights reserved.

  16. Risk stratification of prostate cancer: integrating multiparametric MRI, nomograms and biomarkers

    PubMed Central

    Watson, Matthew J; George, Arvin K; Maruf, Mahir; Frye, Thomas P; Muthigi, Akhil; Kongnyuy, Michael; Valayil, Subin G; Pinto, Peter A

    2016-01-01

    Accurate risk stratification of prostate cancer is achieved with a number of existing tools to ensure the identification of at-risk patients, characterization of disease aggressiveness, prediction of cancer burden and extrapolation of treatment outcomes for appropriate management of the disease. Statistical tables and nomograms using classic clinicopathological variables have long been the standard of care. However, the introduction of multiparametric MRI, along with fusion-guided targeted prostate biopsy and novel biomarkers, are being assimilated into clinical practice. The majority of studies to date present the outcomes of each in isolation. The current review offers a critical and objective assessment regarding the integration of multiparametric MRI and fusion-guided prostate biopsy with novel biomarkers and predictive nomograms in contemporary clinical practice. PMID:27400645

  17. [Prostate histopathology of NIH category IV prostatitis detected by sextant prostate needle biopsy from the patients with high prostatic specific antigen].

    PubMed

    Shimomura, Tatsuya; Kiyota, Hiroshi; Takahashi, Hiroyuki; Madarame, Jun; Kimura, Takahiro; Onodera, Shouichi

    2003-08-01

    Asymptomatic prostatitis is classified as category IV in NIH classification of prostatitis syndrome (1999). No report concerning this category has been present. We investigated this category histopathologically and clinically, in order to clarify the histopathological distribution and its correlation to the clinical features, in this study. Among 785 patients who were suspected prostate cancer because of their high prostatic specific antigen (PSA) values and to have a sextant prostate needle biopsy was performed between January, 1996 and December, 2000, 88 patients (11.2%) were diagnosed as NIH category IV prostatitis (asymptomatic prostatitis). We observed all pathological specimens stained with Hematoxylin-Eosine, and classified them into subtypes according to the classification criteria for prostatitis defined by True et al. (1999). We also investigated the relationship between histopathological distribution and clinical features such as PSA values, PSA density, the incidence of pyuria or bacteriuria. In the histopathological study, grade distributions were 12.5% (11/88) in mild, 71.6% (63/88) in moderate, and 15.9% (14/88) in severe. Location distributions were 2.3% (2/88) in glandular, 68.2% (60/88) in periglandular, and 29.5% (26/88) in stromal. No relationship between these subtypes and clinical features was recognized statistically. However, 7 patients (7.95%) were diagnosed as prostate cancers, later. Pyuria was found in 29.1% (23/79). Bacteriuria was present in 14.3% (11/77). Isolated bacteria were 4 strains of Enterococcus faccalis, 2 strains of each of Pseudomonas aeruginosa and Staphylococcus aureus, and one strain of each of Escherichia coli, Klebsiella oxytoca, Enterobacter cloacae, Enterobacter aerogenes, Staphylococcus haemolyticus, and Staphylococcus epidermidis. Gram positive rod, and Candida sp. No relationship between these subtypes and bacterial species was recognized. These results indicated that the incidence of NIII category IV prostatits

  18. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    PubMed

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  19. Fused-data transrectal EIT for prostate cancer imaging.

    PubMed

    Murphy, Ethan K; Wu, Xiaotian; Halter, Ryan J

    2018-05-25

    Prostate cancer is a significant problem affecting 1 in 7 men. Unfortunately, the diagnostic gold-standard of ultrasound-guided biopsy misses 10%-30% of all cancers. The objective of this study was to develop an electrical impedance tomography (EIT) approach that has the potential to image the entire prostate using multiple impedance measurements recorded between electrodes integrated onto an end-fired transrectal ultrasound (TRUS) device and a biopsy probe (BP). Simulations and sensitivity analyses were used to investigate the best combination of electrodes, and measured tank experiments were used to evaluate a fused-data transrectal EIT (fd-TREIT) and BP approach. Simulations and sensitivity analysis revealed that (1) TREIT measurements are not sufficiently sensitive to image the whole prostate, (2) the combination of TREIT  +  BP measurements increases the sensitive region of TREIT-only measurements by 12×, and (3) the fusion of multiple TREIT  +  BP measurements collected during a routine or customized 12-core biopsy procedure can cover up to 76.1% or 94.1% of a nominal 50 cm 3 prostate, respectively. Three measured tank experiments of the fd-TREIT  +  BP approach successfully and accurately recovered the positions of 2-3 metal or plastic inclusions. The measured tank experiments represent important steps in the development of an algorithm that can combine EIT from multiple locations and from multiple probes-data that could be collected during a routine TRUS-guided 12-core biopsy. Overall, this result is a step towards a clinically deployable impedance imaging approach to scanning the entire prostate, which could significantly help to improve prostate cancer diagnosis.

  20. Role of Magnetic Resonance Imaging Targeted Biopsy in Detection of Prostate Cancer Harboring Adverse Pathological Features of Intraductal Carcinoma and Invasive Cribriform Carcinoma.

    PubMed

    Prendeville, Susan; Gertner, Mark; Maganti, Manjula; Pintilie, Melania; Perlis, Nathan; Toi, Ants; Evans, Andrew J; Finelli, Antonio; van der Kwast, Theodorus H; Ghai, Sangeet

    2018-07-01

    The aim of this study was to compare biopsy detection of intraductal and cribriform pattern invasive prostate carcinoma in multiparametric magnetic resonance imaging positive and negative regions of the prostate. We queried a prospectively maintained, single institution database to identify patients who underwent multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy and concurrent systematic sextant biopsy of magnetic resonance imaging negative regions between January 2013 and May 2016. All multiparametric magnetic resonance imaging targets were reviewed retrospectively by 2 readers for the PI-RADS™ (Prostate Imaging-Reporting and Data System), version 2 score, the maximum dimension, the apparent diffusion coefficient parameter and whether positive or negative on dynamic contrast enhancement sequence. Biopsy slides were reviewed by 2 urological pathologists for Gleason score/Grade Group and the presence or absence of an intraductal/cribriform pattern. A total of 154 patients were included in study. Multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy and systematic sextant biopsy of magnetic resonance imaging negative regions were negative for prostate carcinoma in 51 patients, leaving 103 available for the correlation of multiparametric magnetic resonance imaging and the intraductal/cribriform pattern. Prostate carcinoma was identified by multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy in 93 cases and by systematic sextant biopsy of magnetic resonance imaging negative regions in 76 (p = 0.008). Intraductal/cribriform positive tumor was detected in 23 cases, including at the multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy site in 22 and at the systematic sextant biopsy of magnetic resonance imaging negative region site in 3 (p <0.001). The intraductal/cribriform pattern was significantly associated with a PI-RADS score of 5 and a decreasing apparent diffusion

  1. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement ofmore » the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.« less

  2. Accuracy Study of a Robotic System for MRI-guided Prostate Needle Placement

    PubMed Central

    Seifabadi, Reza; Cho, Nathan BJ.; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fichtinger, Gabor; Iordachita, Iulian

    2013-01-01

    Background Accurate needle placement is the first concern in percutaneous MRI-guided prostate interventions. In this phantom study, different sources contributing to the overall needle placement error of a MRI-guided robot for prostate biopsy have been identified, quantified, and minimized to the possible extent. Methods and Materials The overall needle placement error of the system was evaluated in a prostate phantom. This error was broken into two parts: the error associated with the robotic system (called before-insertion error) and the error associated with needle-tissue interaction (called due-to-insertion error). The before-insertion error was measured directly in a soft phantom and different sources contributing into this part were identified and quantified. A calibration methodology was developed to minimize the 4-DOF manipulator’s error. The due-to-insertion error was indirectly approximated by comparing the overall error and the before-insertion error. The effect of sterilization on the manipulator’s accuracy and repeatability was also studied. Results The average overall system error in phantom study was 2.5 mm (STD=1.1mm). The average robotic system error in super soft phantom was 1.3 mm (STD=0.7 mm). Assuming orthogonal error components, the needle-tissue interaction error was approximated to be 2.13 mm thus having larger contribution to the overall error. The average susceptibility artifact shift was 0.2 mm. The manipulator’s targeting accuracy was 0.71 mm (STD=0.21mm) after robot calibration. The robot’s repeatability was 0.13 mm. Sterilization had no noticeable influence on the robot’s accuracy and repeatability. Conclusions The experimental methodology presented in this paper may help researchers to identify, quantify, and minimize different sources contributing into the overall needle placement error of an MRI-guided robotic system for prostate needle placement. In the robotic system analyzed here, the overall error of the studied system

  3. Accuracy study of a robotic system for MRI-guided prostate needle placement.

    PubMed

    Seifabadi, Reza; Cho, Nathan B J; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M; Fichtinger, Gabor; Iordachita, Iulian

    2013-09-01

    Accurate needle placement is the first concern in percutaneous MRI-guided prostate interventions. In this phantom study, different sources contributing to the overall needle placement error of a MRI-guided robot for prostate biopsy have been identified, quantified and minimized to the possible extent. The overall needle placement error of the system was evaluated in a prostate phantom. This error was broken into two parts: the error associated with the robotic system (called 'before-insertion error') and the error associated with needle-tissue interaction (called 'due-to-insertion error'). Before-insertion error was measured directly in a soft phantom and different sources contributing into this part were identified and quantified. A calibration methodology was developed to minimize the 4-DOF manipulator's error. The due-to-insertion error was indirectly approximated by comparing the overall error and the before-insertion error. The effect of sterilization on the manipulator's accuracy and repeatability was also studied. The average overall system error in the phantom study was 2.5 mm (STD = 1.1 mm). The average robotic system error in the Super Soft plastic phantom was 1.3 mm (STD = 0.7 mm). Assuming orthogonal error components, the needle-tissue interaction error was found to be approximately 2.13 mm, thus making a larger contribution to the overall error. The average susceptibility artifact shift was 0.2 mm. The manipulator's targeting accuracy was 0.71 mm (STD = 0.21 mm) after robot calibration. The robot's repeatability was 0.13 mm. Sterilization had no noticeable influence on the robot's accuracy and repeatability. The experimental methodology presented in this paper may help researchers to identify, quantify and minimize different sources contributing into the overall needle placement error of an MRI-guided robotic system for prostate needle placement. In the robotic system analysed here, the overall error of the studied system

  4. Prostate Cancer Predictive Simulation Modelling, Assessing the Risk Technique (PCP-SMART): Introduction and Initial Clinical Efficacy Evaluation Data Presentation of a Simple Novel Mathematical Simulation Modelling Method, Devised to Predict the Outcome of Prostate Biopsy on an Individual Basis.

    PubMed

    Spyropoulos, Evangelos; Kotsiris, Dimitrios; Spyropoulos, Katherine; Panagopoulos, Aggelos; Galanakis, Ioannis; Mavrikos, Stamatios

    2017-02-01

    We developed a mathematical "prostate cancer (PCa) conditions simulating" predictive model (PCP-SMART), from which we derived a novel PCa predictor (prostate cancer risk determinator [PCRD] index) and a PCa risk equation. We used these to estimate the probability of finding PCa on prostate biopsy, on an individual basis. A total of 371 men who had undergone transrectal ultrasound-guided prostate biopsy were enrolled in the present study. Given that PCa risk relates to the total prostate-specific antigen (tPSA) level, age, prostate volume, free PSA (fPSA), fPSA/tPSA ratio, and PSA density and that tPSA ≥ 50 ng/mL has a 98.5% positive predictive value for a PCa diagnosis, we hypothesized that correlating 2 variables composed of 3 ratios (1, tPSA/age; 2, tPSA/prostate volume; and 3, fPSA/tPSA; 1 variable including the patient's tPSA and the other, a tPSA value of 50 ng/mL) could operate as a PCa conditions imitating/simulating model. Linear regression analysis was used to derive the coefficient of determination (R 2 ), termed the PCRD index. To estimate the PCRD index's predictive validity, we used the χ 2 test, multiple logistic regression analysis with PCa risk equation formation, calculation of test performance characteristics, and area under the receiver operating characteristic curve analysis using SPSS, version 22 (P < .05). The biopsy findings were positive for PCa in 167 patients (45.1%) and negative in 164 (44.2%). The PCRD index was positively signed in 89.82% positive PCa cases and negative in 91.46% negative PCa cases (χ 2 test; P < .001; relative risk, 8.98). The sensitivity was 89.8%, specificity was 91.5%, positive predictive value was 91.5%, negative predictive value was 89.8%, positive likelihood ratio was 10.5, negative likelihood ratio was 0.11, and accuracy was 90.6%. Multiple logistic regression revealed the PCRD index as an independent PCa predictor, and the formulated risk equation was 91% accurate in predicting the probability of

  5. Complications following prostate needle biopsy requiring hospital admission or emergency department visits - experience from 1000 consecutive cases.

    PubMed

    Pinkhasov, G Igor; Lin, Yu-Kuan; Palmerola, Ricardo; Smith, Paul; Mahon, Frank; Kaag, Matthew G; Dagen, J Edward; Harpster, Lewis E; Reese, Carl T; Raman, Jay D

    2012-08-01

    • To review a contemporary cohort of patients undergoing a transrectal ultrasound-guided prostate needle biopsy (TRUS PNBx) at a single centre to determine the incidence of major complications necessitating hospital admission or emergency department (ED) visits. • The charts of 1000 consecutive patients undergoing TRUS PNBx were reviewed. • All patients received peri-procedural antibiotic prophylaxis with either ciprofloxacin or co-trimoxazole. • Hospital admission and ED visits within 30 days of the procedure were identified for indication, management and outcome. • Patient comorbidities and biopsy characteristics were reviewed for association with complications. • Of the 1000 patients, 25 (2.5%) had post-biopsy complications requiring hospital admission or an ED visit. • Indications included twelve patients (1.2%) with urosepsis, eight (0.8%) with acute urinary retention requiring urethral catheterization, four (0.4%) with gross haematuria requiring bladder irrigation for <24 h, and one (0.1%) with a transient ischaemia attack 1 day after biopsy. • Patients with urosepsis had an average hospitalization of 5 days, and 75% carried quinolone-resistant Escherichia coli organisms. • All patients with urinary retention had catheters removed within 10 days. No patients with haematuria required a blood transfusion. • No demographic or biopsy variables were particularly associated with development of a post-procedure complication. • In this large contemporary series of TRUS PNBx, we observed a 2.5% rate of major complications requiring hospital admission or an ED visit. • No clinical or biopsy variables were directly associated with development of complications. • These data may be valuable when counselling patients before biopsy. © 2012 THE AUTHORS. BJU INTERNATIONAL © 2012 BJU INTERNATIONAL.

  6. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma--results in 103 biopsies.

    PubMed

    Vandervelde, C; Kamani, T; Varghese, A; Ramesar, K; Grace, R; Howlett, D C

    2008-04-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  7. Is the Ellipsoid Formula the New Standard for 3-Tesla MRI Prostate Volume Calculation without Endorectal Coil?

    PubMed

    Haas, Matthias; Günzel, Karsten; Miller, Kurt; Hamm, Bernd; Cash, Hannes; Asbach, Patrick

    2017-01-01

    Prostate volume in multiparametric MRI (mpMRI) is of clinical importance. For 3-Tesla mpMRI without endorectal coil, there is no distinctive standard for volume calculation. We tested the accuracy of the ellipsoid formula with planimetric volume measurements as reference and investigated the correlation of gland volume and cancer detection rate on MRI/ultrasound (MRI/US) fusion-guided biopsy. One hundred forty-three patients with findings on 3-Tesla mpMRI suspicious of cancer and subsequent MRI/US fusion-guided targeted biopsy and additional systematic biopsy were analyzed. T2-weighted images were used for measuring the prostate diameters and for planimetric volume measurement by a segmentation software. Planimetric and calculated prostate volumes were compared with clinical data. The median prostate volume was 48.1 ml (interquartile range (IQR) 36.9-62.1 ml). Volume calculated by the ellipsoid formula showed a strong concordance with planimetric volume, with a tendency to underestimate prostate volume (median volume 43.1 ml (IQR 31.2-58.8 ml); r = 0.903, p < 0.001). There was a moderate, significant inverse correlation of prostate volume to a positive biopsy result (r = -0.24, p = 0.004). The ellipsoid formula gives sufficient approximation of prostate volume on 3-Tesla mpMRI without endorectal coil. It allows a fast, valid volume calculation in prostate MRI datasets. © 2016 S. Karger AG, Basel.

  8. How Precisely Can Prostate Cancer Be Managed?

    PubMed Central

    2016-01-01

    Progress has been made in applying genetic information to disease management in the postgenomic era, and precision medicine is emerging in prostate cancer management. The prostate health index, the 4-kallikrein (4K) score, and the PCA3, TMPRSS2-ERG, and Prostarix tests have potential for refining prostate cancer screening in conjunction with traditional prostate-specific antigen testing. The Confirm MDx and PCA3 tests have shown promise in identifying men who need be rebiopsied after a primary negative biopsy. Oncotype DX, Prolaris, the biopsy-based Decipher prostate cancer test, and ProMark may improve predictive risk stratification in addition to the traditional Gleason score and tumor stage. Decipher and Prolaris may predict biochemical recurrence and metastasis after radical prostatectomy and possibly help identify patients who need adjuvant therapy. Androgen receptor splice variant 7 appears effective in guiding the selection of second hormonal manipulation with abiraterone or enzalutamide versus chemotherapy when treating metastatic castration-resistant prostate cancer. PMID:27915475

  9. Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.

    PubMed

    Li, Zong Ming; Wu, Gang; Han, Xin Wei; Ren, Ke Wei; Zhu, Ming

    2014-01-01

    We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy.

  10. Radiology-guided forceps biopsy and airway stenting in severe airway stenosis

    PubMed Central

    Li, Zong-Ming; Wu, Gang; Han, Xin-Wei; Ren, Ke-Wei; Zhu, Ming

    2014-01-01

    PURPOSE We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. MATERIALS AND METHODS This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. RESULTS The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. CONCLUSION Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy. PMID:24808434

  11. [Comparative study of histological results between resection and biopsy of the prostate].

    PubMed

    Mathieu, R; Tibari, Y; Verhoest, G; Vincendeau, S; Manunta, A; Rioux-Leclercq, N; Bensalah, K

    2014-05-01

    To evaluate the histological correlation between transuretral resection chips and biopsy cores within a population of patients who underwent resection of prostate (TURP) and prostate biopsies (BPx). Clinical and tumoral data of 77 patients who had both procedures simultaneously or with a slight delay were collected. According to the presence of prostate cancer (Pca), 4 groups were defined: group 1 (TURP and BPx negative), group 2 (TURP positive, BPx negative), group 3 (TURP negative, BPx positive), group 4 (TURP and BPx positive). Means and proportions were compared using Anova and χ(2) test, respectively. The patients were older in groups 3 and 4 (79 and 76 respectively, P=0.65). The PSA was higher in the groups 3 and 4 (64 and 55 ng/mL) than the groups 1 and 2 (10.6 et 16 respectively, P=0.23). The number of positive biopsy was higher in the group 4 than the group 3 (5.6 vs. 4.6, P<0.0001), the chips were more invaded in the group 4 than the group 2 (41% vs. 11% P<0.0001), the Gleason score at TURP was higher in the group 4 than the group 2 (7.5 vs. 6.2 P<0.0001). Our study underlines that the Pca of transition and peripheral zones seems to have distinct characteristics. When chips of TURP and BPx were both invaded, it was due to an aggressive cancer. The decision to explore the peripheral zone in the case of positive TURP must take clinical context into consideration. Copyright © 2013. Published by Elsevier Masson SAS.

  12. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    PubMed

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  13. Prostate biopsies assisted by comanipulated probe-holder: first in man.

    PubMed

    Vitrani, Marie-Aude; Baumann, Michael; Reversat, David; Morel, Guillaume; Moreau-Gaudry, Alexandre; Mozer, Pierre

    2016-06-01

    A comanipulator for assisting endorectal prostate biopsies is evaluated through a first-in-man clinical trial. This lightweight system, based on conventional robotic components, possesses six degrees of freedom. It uses three electric motors and three brakes. It features a free mode, where its low friction and inertia allow for natural manipulation of the probe and a locked mode, exhibiting both a very low stiffness and a high steady-state precision. Clinical trials focusing on the free mode and the locked mode of the robot are presented. The objective was to evaluate the practical usability and performance of the robot during clinical procedures. A research protocol for a prospective randomized clinical trial has been designed. Its specific goal was to compare the accuracy of biopsies performed with and without the assistance of the comanipulator. The accuracy is compared between biopsies performed with and without the assistance of the comanipulator, across the 10 first patients included in the trial. Results show a statistically significant increase in the precision.

  14. Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) significantly improve prostate cancer detection at initial biopsy in a total PSA range of 2-10 ng/ml.

    PubMed

    Ferro, Matteo; Bruzzese, Dario; Perdonà, Sisto; Marino, Ada; Mazzarella, Claudia; Perruolo, Giuseppe; D'Esposito, Vittoria; Cosimato, Vincenzo; Buonerba, Carlo; Di Lorenzo, Giuseppe; Musi, Gennaro; De Cobelli, Ottavio; Chun, Felix K; Terracciano, Daniela

    2013-01-01

    Many efforts to reduce prostate specific antigen (PSA) overdiagnosis and overtreatment have been made. To this aim, Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) have been proposed as new more specific biomarkers. We evaluated the ability of phi and PCA3 to identify prostate cancer (PCa) at initial prostate biopsy in men with total PSA range of 2-10 ng/ml. The performance of phi and PCA3 were evaluated in 300 patients undergoing first prostate biopsy. ROC curve analyses tested the accuracy (AUC) of phi and PCA3 in predicting PCa. Decision curve analyses (DCA) were used to compare the clinical benefit of the two biomarkers. We found that the AUC value of phi (0.77) was comparable to those of %p2PSA (0.76) and PCA3 (0.73) with no significant differences in pairwise comparison (%p2PSA vs phi p = 0.673, %p2PSA vs. PCA3 p = 0.417 and phi vs. PCA3 p = 0.247). These three biomarkers significantly outperformed fPSA (AUC = 0.60), % fPSA (AUC = 0.62) and p2PSA (AUC = 0.63). At DCA, phi and PCA3 exhibited a very close net benefit profile until the threshold probability of 25%, then phi index showed higher net benefit than PCA3. Multivariable analysis showed that the addition of phi and PCA3 to the base multivariable model (age, PSA, %fPSA, DRE, prostate volume) increased predictive accuracy, whereas no model improved single biomarker performance. Finally we showed that subjects with active surveillance (AS) compatible cancer had significantly lower phi and PCA3 values (p<0.001 and p = 0.01, respectively). In conclusion, both phi and PCA3 comparably increase the accuracy in predicting the presence of PCa in total PSA range 2-10 ng/ml at initial biopsy, outperforming currently used %fPSA.

  15. A novel urinary long non-coding RNA transcript improves diagnostic accuracy in patients undergoing prostate biopsy.

    PubMed

    Zhang, Wei; Ren, Shan-Cheng; Shi, Xiao-Lei; Liu, Ya-Wei; Zhu, Ya-Sheng; Jing, Tai-Le; Wang, Fu-Bo; Chen, Rui; Xu, Chuan-Liang; Wang, Hui-Qing; Wang, Hai-Feng; Wang, Yan; Liu, Bing; Li, Yao-Ming; Fang, Zi-Yu; Guo, Fei; Lu, Xin; Shen, Dan; Gao, Xu; Hou, Jian-Guo; Sun, Ying-Hao

    2015-05-01

    Long non-coding RNA (LncRNA) PCA3 has been a well-established urine biomarker for the detection of prostate cancer (PCa). Our previous study showed a novel LncRNA FR0348383 is up-regulated in over 70% of PCa compared with matched benign tissues. The aim of this study was to evaluate the diagnostic value of urinary FR0348383 for men undergoing prostate biopsy due to elevated PSA (PSA > 4.0 ng/ml) and/or abnormal digital rectal examination (DRE). Post-DRE first-catch urine specimens prior to prostate biopsies were prospectively collected. After the whole transcriptome amplification, quantitative real time polymerase chain reaction was applied to quantify urine FR0348383 and PSA levels. The FR0348383 score was calculated as the ratio of PSA and FR0348383 mRNA (PSA mRNA/FR0348383 mRNA × 1000). The diagnostic value of FR0348383 score was evaluated by logistic regression and decision curve analysis. 213 cases with urine samples containing sufficient mRNA were included, 94 cases had serum PSA level 4.0-10.0 ng/ml. PCa was identified in 72 cases. An increasing FR0348383 score was correlated with an increasing probability of a positive biopsy (P < 0.001). Multivariable logistic analysis indicated FR0348383 score (P < 0.001), PSA (P = 0.004), age (P = 0.007), prostate volume (P < 0.001) were independent predictors of PCa. ROC analysis demonstrated FR0348383 score outperformed PSA, %free PSA, and PSA Density in the prediction of PCa in the subgroup of patients with grey area PSA (AUC: 0.815 vs. 0.562 vs. 0.599 vs. 0.645). When using a probability threshold of 30% in the grey zone cohort, The FR0348383 score would save 52.0% of avoidable biopsies without missing any high grade cancers. FR0348383 transcript in post-DRE urine may be a novel biomarker for detection of PCa with great diagnostic value, especially in the grey zone cohort. The application of FR0348383 score in clinical practice might avoid unnecessary prostate biopsies and increase

  16. MRI-Derived Cellularity Index as a Potential Noninvasive Imaging Biomarker of Prostate Cancer

    DTIC Science & Technology

    2014-10-01

    previously diagnosed with prostate cancer via standard transrectal ultrasound guided prostate biopsy after prostate specific antigen (PSA) elevation or...around 70% and specificity of 55% (72). Functional MR techniques enhance detection, grading, and staging of prostate cancer through the use of dynamic...and specificity in the diagnosis of prostate cancer by increasing tumor conspicuity on DWI or quantitative ADC maps. How- ever, hemorrhage, inflammatory

  17. Implementation of a 5-Minute Magnetic Resonance Imaging Screening Protocol for Prostate Cancer in Men With Elevated Prostate-Specific Antigen Before Biopsy.

    PubMed

    Weiss, Jakob; Martirosian, Petros; Notohamiprodjo, Mike; Kaufmann, Sascha; Othman, Ahmed E; Grosse, Ulrich; Nikolaou, Konstantin; Gatidis, Sergios

    2018-03-01

    The aims of this study were to establish a 5-minute magnetic resonance (MR) screening protocol for prostate cancer in men before biopsy and to evaluate effects on Prostate Imaging Reporting and Data System (PI-RADS) V2 scoring in comparison to a conventional, fully diagnostic multiparametric MR imaging (mpMRI) approach. Fifty-two patients with elevated prostate-specific antigen levels and without prior biopsy were prospectively included in this institutional review board-approved study. In all patients, an mpMRI protocol according to the PI-RADS recommendations was acquired on a 3 T MRI system. In addition, an accelerated diffusion-weighted imaging sequence was acquired using simultaneous multislice technique (DW-EPISMS). Two readers independently evaluated the images for the presence/absence of prostate cancer according to the PI-RADS criteria and for additional findings. In a first reading session, only the screening protocol consisting of axial T2-weighted and DW-EPISMS images was made available. In a subsequent reading session, the mpMRI protocol was assessed blinded to the results of the first reading, serving as reference standard. Both readers successfully established a final diagnosis according to the PI-RADS criteria in the screening and mpMRI protocol. Mean lesion size was 1.2 cm in the screening and 1.4 cm in the mpMRI protocol (P = 0.4) with 35% (18/52) of PI-RADS IV/V lesions. Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100% for both readers with no significant differences in comparison to the mpMRI standard (P = 1.0). In 3 patients, suspicious lymph nodes were reported as additional finding, which were equally detectable in the screening and mpMRI protocol. A 5-minute MR screening protocol for prostate cancer in men with elevated prostate-specific antigen levels before biopsy is applicable for clinical routine with similar diagnostic performance as the full diagnostic mpMRI approach.

  18. Targeted Prostate Biopsy: Lessons Learned Midst the Evolution of a Disruptive Technology.

    PubMed

    Nassiri, Nima; Natarajan, Shyam; Margolis, Daniel J; Marks, Leonard S

    2015-09-01

    Lessons learned during a 6-year experience with more than 1200 patients undergoing targeted prostate biopsy via MRI/ultrasound fusion are reported: (1) the procedure is safe and efficient, requiring some 15-20 minutes in an office setting; (2) MRI is best performed by a radiologist with specialized training, using a transabdominal multiparametric approach and preferably a 3T magnet; (3) grade of MRI suspicion is the most powerful predictor of biopsy results, eg, Grade 5 usually represents cancer; (4) some potentially important cancers (15%-30%) are MRI-invisible; (5) Targeted biopsies provide >80% concordance with whole-organ pathology. Early enthusiasm notwithstanding, cost-effectiveness is yet to be resolved, and the technologies remain in evolution. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. TARGETED PROSTATE BIOPSY: LESSONS LEARNED MIDST THE EVOLUTION OF A DISRUPTIVE TECHNOLOGY

    PubMed Central

    Nassiri, Nima; Natarajan, Shyam; Margolis, Daniel J.; Marks, Leonard S.

    2015-01-01

    Lessons learned during a 6-year experience with more than 1200 patients undergoing targeted prostate biopsy via MRI/US fusion are reported: (1) The procedure is safe and efficient, requiring some 15–20 minutes in an office setting; (2) MRI is best performed by a radiologist with specialized training, employing a trans-abdominal multi-parametric approach and preferably a 3T magnet; (3) Grade of MRI suspicion is the most powerful predictor of biopsy results, e.g., Grade 5 usually represents cancer; (4) Some potentially-important cancers (15%–30%) are MRI-invisible; (5) Targeted biopsies provide >80% concordance with whole-organ pathology. Early enthusiasm notwithstanding, cost-effectiveness is yet to be resolved, and the technologies remain in evolution. PMID:26166671

  20. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    PubMed

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary

  1. A haptic unit designed for magnetic-resonance-guided biopsy.

    PubMed

    Tse, Z T H; Elhawary, H; Rea, M; Young, I; Davis, B L; Lamperth, M

    2009-02-01

    The magnetic fields present in the magnetic resonance (MR) environment impose severe constraints on any mechatronic device present in its midst, requiring alternative actuators, sensors, and materials to those conventionally used in traditional system engineering. In addition the spatial constraints of closed-bore scanners require a physical separation between the radiologist and the imaged region of the patient. This configuration produces a loss of the sense of touch from the target anatomy for the clinician, which often provides useful information. To recover the force feedback from the tissue, an MR-compatible haptic unit, designed to be integrated with a five-degrees-of-freedom mechatronic system for MR-guided prostate biopsy, has been developed which incorporates position control and force feedback to the operator. The haptic unit is designed to be located inside the scanner isocentre with the master console in the control room. MR compatibility of the device has been demonstrated, showing a negligible degradation of the signal-to-noise ratio and virtually no geometric distortion. By combining information from the position encoder and force sensor, tissue stiffness measurement along the needle trajectory is demonstrated in a lamb liver to aid diagnosis of suspected cancerous tissue.

  2. The Efficacy of Multiparametric Magnetic Resonance Imaging and Magnetic Resonance Imaging Targeted Biopsy in Risk Classification for Patients with Prostate Cancer on Active Surveillance.

    PubMed

    Recabal, Pedro; Assel, Melissa; Sjoberg, Daniel D; Lee, Daniel; Laudone, Vincent P; Touijer, Karim; Eastham, James A; Vargas, Hebert A; Coleman, Jonathan; Ehdaie, Behfar

    2016-08-01

    We determined whether multiparametric magnetic resonance imaging targeted biopsies may replace systematic biopsies to detect higher grade prostate cancer (Gleason score 7 or greater) and whether biopsy may be avoided based on multiparametric magnetic resonance imaging among men with Gleason 3+3 prostate cancer on active surveillance. We identified men with previously diagnosed Gleason score 3+3 prostate cancer on active surveillance who underwent multiparametric magnetic resonance imaging and a followup prostate biopsy. Suspicion for higher grade cancer was scored on a standardized 5-point scale. All patients underwent a systematic biopsy. Patients with multiparametric magnetic resonance imaging regions of interest also underwent magnetic resonance imaging targeted biopsy. The detection rate of higher grade cancer was estimated for different multiparametric magnetic resonance imaging scores with the 3 biopsy strategies of systematic, magnetic resonance imaging targeted and combined. Of 206 consecutive men on active surveillance 135 (66%) had a multiparametric magnetic resonance imaging region of interest. Overall, higher grade cancer was detected in 72 (35%) men. A higher multiparametric magnetic resonance imaging score was associated with an increased probability of detecting higher grade cancer (Wilcoxon-type trend test p <0.0001). Magnetic resonance imaging targeted biopsy detected higher grade cancer in 23% of men. Magnetic resonance imaging targeted biopsy alone missed higher grade cancers in 17%, 12% and 10% of patients with multiparametric magnetic resonance imaging scores of 3, 4 and 5, respectively. Magnetic resonance imaging targeted biopsies increased the detection of higher grade cancer among men on active surveillance compared to systematic biopsy alone. However, a clinically relevant proportion of higher grade cancer was detected using only systematic biopsy. Despite the improved detection of disease progression using magnetic resonance imaging

  3. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of

  4. Assessment of Prospectively Assigned Likert Scores for Targeted Magnetic Resonance Imaging-Transrectal Ultrasound Fusion Biopsies in Patients with Suspected Prostate Cancer.

    PubMed

    Costa, Daniel N; Lotan, Yair; Rofsky, Neil M; Roehrborn, Claus; Liu, Alexander; Hornberger, Brad; Xi, Yin; Francis, Franto; Pedrosa, Ivan

    2016-01-01

    We assess the performance of prospectively assigned magnetic resonance imaging based Likert scale scores for the detection of clinically significant prostate cancer, and analyze the pre-biopsy imaging variables associated with increased cancer detection using targeted magnetic resonance imaging-transrectal ultrasound fusion biopsy. In this retrospective review of prospectively generated data including men with abnormal multiparametric prostate magnetic resonance imaging (at least 1 Likert score 3 or greater lesion) who underwent subsequent targeted magnetic resonance imaging-transrectal ultrasound fusion biopsy, we determined the association between different imaging variables (Likert score, lesion size, lesion location, prostate volume, radiologist experience) and targeted biopsy positivity rate. We also compared the detection of clinically significant cancer according to Likert scale scores. Tumors with high volume (50% or more of any core) Gleason score 3+4 or any tumor with greater Gleason score were considered clinically significant. Each lesion served as the elementary unit for analysis. We used logistic regression for univariate and multivariate (stepwise selection) analysis to assess for an association between targeted biopsy positivity rate and each tested variable. The relationship between Likert scale and Gleason score was evaluated using the Spearman correlation coefficient. A total of 161 men with 244 lesions met the study eligibility criteria. Targeted biopsies diagnosed cancer in 41% (66 of 161) of the men and 41% (99 of 244) of the lesions. The Likert score was the strongest predictor of targeted biopsy positivity (OR 3.7, p <0.0001). Other imaging findings associated with a higher targeted biopsy positivity rate included smaller prostate volume (OR 0.7, p <0.01), larger lesion size (OR 2.2, p <0.001) and anterior location (OR 2.0, p=0.01). On multiple logistic regression analysis Likert score, lesion size and prostate volume were significant

  5. Single-Institution Results of Image-Guided Nonplugged Percutaneous Versus Transjugular Liver Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardman, Rulon L., E-mail: hardmanr@uthscsa.edu; Perrich, Kiley D.; Silas, Anne M.

    2011-04-15

    Purpose: To retrospectively review patients who underwent transjugular and image-guided percutaneous biopsy and compare the relative risk of ascites, thrombocytopenia, and coagulopathy. Materials and Methods: From August 2001 through February 2006, a total of 238 liver biopsies were performed. The radiologist reviewed all patient referrals for transjugular biopsy. These patients either underwent transjugular biopsy or were reassigned to percutaneous biopsy (crossover group). Patients referred to percutaneous image-guided liver biopsy underwent this same procedure. Biopsies were considered successful if a tissue diagnosis could be made from the samples obtained. Results: A total of 36 transjugular biopsies were performed with 3 totalmore » (8.3%) and 1 major (2.8%) complications. A total of 171 percutaneous biopsies were performed with 10 (5.8%) total and 3 (1.8%) major complications. The crossover group showed a total of 4 (12.9%) complications with 1 (3.2%) major complication. Sample adequacy was 91.9% for transjugular and 99.5% for percutaneous biopsy. Conclusion: Both transjugular and percutaneous liver biopsy techniques are efficacious and safe. Contraindications such as thrombocytopenia, coagulopathy, and ascites are indicators of greater complications but are not necessarily prevented by transjugular biopsy. Percutaneous biopsy more frequently yields a diagnostic specimen than transjugular biopsy.« less

  6. Use of the Prostate Core Mitomic Test in Repeated Biopsy Decision-Making: Real-World Assessment of Clinical Utility in a Multicenter Patient Population.

    PubMed

    Legisi, Lorena; DeSa, Elise; Qureshi, M Nasar

    2016-12-01

    Prostate cancer is the most common cancer diagnosed in men in developed countries. Using molecular testing may help to improve outcomes in this clinically challenging group. Since 2011, the Prostate Core Mitomic Test (PCMT), which quantifies a 3.4-kb mitochondrial DNA deletion strongly associated with prostate cancer, has been used by more than 50 urology practices accessing pathology services through our laboratory in New Jersey. However, the use of a molecular test can only be beneficial if it affects patient management and improves outcomes. To determine whether repeated biopsy decision-making was affected in a quantifiable manner through the adjunct use of molecular testing with the PCMT. In this observational study we conducted 2 independent, structured query language database queries of our patient records at our laboratory, QDx Pathology Services, in Cranford, NJ. Query 1 included all men who had a negative prostate biopsy and a negative PCMT between February 1, 2011, and June 30, 2013. Men with a previous diagnosis of cancer were excluded. Query 2 included all men who had a negative prostate biopsy and a repeated biopsy between February 1, 2011, and September 30, 2013. The data exported for each query included the unique specimen number for an index biopsy, the interval between biopsies where present, the unique specimen number for a follow-up biopsy where present, histopathology for all biopsies, the biopsy procedure dates, the patient's date of birth, and the PCMT result when utilized. The patient rebiopsy rates and intervals were compared between the patients who were using PCMT and those who were not to assess whether the adjunct use of the PCMT impacted the rebiopsy decision-making process. Query 1 identified 644 men who had a negative biopsy and a negative PCMT result within the study period. Query 2 identified 823 men with a repeat biopsy after the initial negative index biopsy within the study period. Of these men, 132 had PCMT to inform their care

  7. A CT-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels

    PubMed Central

    Lin, Chia-Ying; Ou, Ming-Ching; Liu, Yi-Sheng; Chuang, Ming-Tsung; Shan, Yan-Shen; Tsai, Hong-Ming; Wang, Chien-Kuo; Tsai, Yi-Shan

    2017-01-01

    Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3%). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4%), and a successful diagnosis was made based on the biopsy outcome in 96.7% patients. Complications occurred in five patients (4.1%); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate. PMID:29205187

  8. Targeted proteomics identifies liquid-biopsy signatures for extracapsular prostate cancer

    PubMed Central

    Kim, Yunee; Jeon, Jouhyun; Mejia, Salvador; Yao, Cindy Q; Ignatchenko, Vladimir; Nyalwidhe, Julius O; Gramolini, Anthony O; Lance, Raymond S; Troyer, Dean A; Drake, Richard R; Boutros, Paul C; Semmes, O. John; Kislinger, Thomas

    2016-01-01

    Biomarkers are rapidly gaining importance in personalized medicine. Although numerous molecular signatures have been developed over the past decade, there is a lack of overlap and many biomarkers fail to validate in independent patient cohorts and hence are not useful for clinical application. For these reasons, identification of novel and robust biomarkers remains a formidable challenge. We combine targeted proteomics with computational biology to discover robust proteomic signatures for prostate cancer. Quantitative proteomics conducted in expressed prostatic secretions from men with extraprostatic and organ-confined prostate cancers identified 133 differentially expressed proteins. Using synthetic peptides, we evaluate them by targeted proteomics in a 74-patient cohort of expressed prostatic secretions in urine. We quantify a panel of 34 candidates in an independent 207-patient cohort. We apply machine-learning approaches to develop clinical predictive models for prostate cancer diagnosis and prognosis. Our results demonstrate that computationally guided proteomics can discover highly accurate non-invasive biomarkers. PMID:27350604

  9. Relationship of chronic histologic prostatic inflammation in biopsy specimens with serum isoform [-2]proPSA (p2PSA), %p2PSA, and prostate health index in men with a total prostate-specific antigen of 4-10 ng/ml and normal digital rectal examination.

    PubMed

    Lazzeri, Massimo; Abrate, Alberto; Lughezzani, Giovanni; Gadda, Giulio Maria; Freschi, Massimo; Mistretta, Francesco; Lista, Giuliana; Fossati, Nicola; Larcher, Alessandro; Kinzikeeva, Ella; Buffi, Nicolòmaria; Dell'Acqua, Vincenzo; Bini, Vittorio; Montorsi, Francesco; Guazzoni, Giorgio

    2014-03-01

    To investigate the relationship between serum [-2]proPSA (p2PSA) and derivatives with chronic histologic prostatic inflammation (CHPI) in men undergoing prostate biopsy for suspected prostate cancer (PCa). This nested case-control study resulted from an observational prospective trial for the definition of sensibility, specificity, and accuracy of p2PSA, %p2PSA, and Beckman Coulter Prostate Health Index (PHI), in men undergoing prostate biopsy, with a total prostate-specific antigen (PSA) of 4-10 ng/mL and normal digital rectal examination. CHPI was the outcome of interest and defined as the presence of moderate to large infiltration of lymphomononuclear cells with interstitial and/or glandular disruption in absence of PCa. p2PSA, %p2PSA, and PHI were considered the index tests and compared with the established biomarker reference standard tests: tPSA, fPSA, %fPSA. Of 267 patients subjected to prostate biopsy, 73 (27.3%) patients were diagnosed with CHPI. Comparing CHPI with PCa patients, %p2PSA and PHI were found to be significantly lower, whereas fPSA and %fPSA were significantly higher. %p2PSA and PHI were the most accurate predictors of CHPI at biopsy, significantly outperforming tPSA, fPSA, and %fPSA. On the contrary, no significant differences were found in PSA, p2PSA, and derivatives between CHPI and benign prostatic hyperplasia (BPH) patients. Our findings showed that p2PSA, %p2PSA, and PHI values might discriminate PCa from CHPI or BPH, but not CHPI from BPH, in men with a total PSA 4-10 ng/mL and normal digital rectal examination. p2PSA isoform and its derivatives could be useful in clinical decision making to avoid unnecessary biopsies in patients with CHPI and elevated tPSA value. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) Significantly Improve Prostate Cancer Detection at Initial Biopsy in a Total PSA Range of 2–10 ng/ml

    PubMed Central

    Perdonà, Sisto; Marino, Ada; Mazzarella, Claudia; Perruolo, Giuseppe; D’Esposito, Vittoria; Cosimato, Vincenzo; Buonerba, Carlo; Di Lorenzo, Giuseppe; Musi, Gennaro; De Cobelli, Ottavio; Chun, Felix K.; Terracciano, Daniela

    2013-01-01

    Many efforts to reduce prostate specific antigen (PSA) overdiagnosis and overtreatment have been made. To this aim, Prostate Health Index (Phi) and Prostate Cancer Antigen 3 (PCA3) have been proposed as new more specific biomarkers. We evaluated the ability of phi and PCA3 to identify prostate cancer (PCa) at initial prostate biopsy in men with total PSA range of 2–10 ng/ml. The performance of phi and PCA3 were evaluated in 300 patients undergoing first prostate biopsy. ROC curve analyses tested the accuracy (AUC) of phi and PCA3 in predicting PCa. Decision curve analyses (DCA) were used to compare the clinical benefit of the two biomarkers. We found that the AUC value of phi (0.77) was comparable to those of %p2PSA (0.76) and PCA3 (0.73) with no significant differences in pairwise comparison (%p2PSA vs phi p = 0.673, %p2PSA vs. PCA3 p = 0.417 and phi vs. PCA3 p = 0.247). These three biomarkers significantly outperformed fPSA (AUC = 0.60), % fPSA (AUC = 0.62) and p2PSA (AUC = 0.63). At DCA, phi and PCA3 exhibited a very close net benefit profile until the threshold probability of 25%, then phi index showed higher net benefit than PCA3. Multivariable analysis showed that the addition of phi and PCA3 to the base multivariable model (age, PSA, %fPSA, DRE, prostate volume) increased predictive accuracy, whereas no model improved single biomarker performance. Finally we showed that subjects with active surveillance (AS) compatible cancer had significantly lower phi and PCA3 values (p<0.001 and p = 0.01, respectively). In conclusion, both phi and PCA3 comparably increase the accuracy in predicting the presence of PCa in total PSA range 2–10 ng/ml at initial biopsy, outperforming currently used %fPSA. PMID:23861782

  11. Percentage of Positive Biopsy Cores: A Better Risk Stratification Model for Prostate Cancer?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang Jiayi; Vicini, Frank A.; Williams, Scott G.

    2012-07-15

    Purpose: To assess the prognostic value of the percentage of positive biopsy cores (PPC) and perineural invasion in predicting the clinical outcomes after radiotherapy (RT) for prostate cancer and to explore the possibilities to improve on existing risk-stratification models. Methods and Materials: Between 1993 and 2004, 1,056 patients with clinical Stage T1c-T3N0M0 prostate cancer, who had four or more biopsy cores sampled and complete biopsy core data available, were treated with external beam RT, with or without a high-dose-rate brachytherapy boost at William Beaumont Hospital. The median follow-up was 7.6 years. Multivariate Cox regression analysis was performed with PPC, Gleasonmore » score, pretreatment prostate-specific antigen, T stage, PNI, radiation dose, androgen deprivation, age, prostate-specific antigen frequency, and follow-up duration. A new risk stratification (PPC classification) was empirically devised to incorporate PPC and replace the T stage. Results: On multivariate Cox regression analysis, the PPC was an independent predictor of distant metastasis, cause-specific survival, and overall survival (all p < .05). A PPC >50% was associated with significantly greater distant metastasis (hazard ratio, 4.01; 95% confidence interval, 1.86-8.61), and its independent predictive value remained significant with or without androgen deprivation therapy (all p < .05). In contrast, PNI and T stage were only predictive for locoregional recurrence. Combining the PPC ({<=}50% vs. >50%) with National Comprehensive Cancer Network risk stratification demonstrated added prognostic value of distant metastasis for the intermediate-risk (hazard ratio, 5.44; 95% confidence interval, 1.78-16.6) and high-risk (hazard ratio, 4.39; 95% confidence interval, 1.70-11.3) groups, regardless of the use of androgen deprivation and high-dose RT (all p < .05). The proposed PPC classification appears to provide improved stratification of the clinical outcomes relative to the

  12. The influence of prostate-specific antigen density on positive and negative predictive values of multiparametric magnetic resonance imaging to detect Gleason score 7-10 prostate cancer in a repeat biopsy setting.

    PubMed

    Hansen, Nienke L; Barrett, Tristan; Koo, Brendan; Doble, Andrew; Gnanapragasam, Vincent; Warren, Anne; Kastner, Christof; Bratt, Ola

    2017-05-01

    To evaluate the influence of prostate-specific antigen density (PSAD) on positive (PPV) and negative (NPV) predictive values of multiparametric magnetic resonance imaging (mpMRI) to detect Gleason score ≥7 cancer in a repeat biopsy setting. Retrospective study of 514 men with previous prostate biopsy showing no or Gleason score 6 cancer. All had mpMRI, graded 1-5 on a Likert scale for cancer suspicion, and subsequent targeted and 24-core systematic image-fusion guided transperineal biopsy in 2013-2015. The NPVs and PPVs of mpMRIs for detecting Gleason score ≥7 cancer were calculated (±95% confidence intervals) for PSAD ≤0.1, 0.1-0.2, ≤0.2 and >0.2 ng/mL/mL, and compared by chi-square test for linear trend. Gleason score ≥7 cancer was detected in 31% of the men. The NPV of Likert 1-2 mpMRI was 0.91 (±0.04) with a PSAD of ≤0.2 ng/mL/mL and 0.71 (±0.16) with a PSAD of >0.2 ng/mL/mL (P = 0.003). For Likert 3 mpMRI, PPV was 0.09 (±0.06) with a PSAD of ≤0.2 ng/mL/mL and 0.44 (±0.19) with a PSAD of >0.2 ng/mL/mL (P = 0.002). PSAD also significantly affected the PPV of Likert 4-5 mpMRI lesions: the PPV was 0.47 (±0.08) with a PSAD of ≤0.2 ng/mL/mL and 0.66 (±0.10) with a PSAD of >0.2 ng/mL/mL (P < 0.001). In a repeat biopsy setting, a PSAD of ≤0.2 ng/mL/mL is associated with low detection of Gleason score ≥7 prostate cancer, not only in men with negative mpMRI, but also in men with equivocal imaging. Surveillance, rather than repeat biopsy, may be appropriate for these men. Conversely, biopsies are indicated in men with a high PSAD, even if an mpMRI shows no suspicious lesion, and in men with an mpMRI suspicious for cancer, even if the PSAD is low. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  13. Role of imaging and biopsy to assess local recurrence after definitive treatment for prostate carcinoma (surgery, radiotherapy, cryotherapy, HIFU).

    PubMed

    Martino, Pasquale; Scattoni, Vincenzo; Galosi, Andrea B; Consonni, Paolo; Trombetta, Carlo; Palazzo, Silvano; Maccagnano, Carmen; Liguori, Giovanni; Valentino, Massimo; Battaglia, Michele; Barozzi, Libero

    2011-10-01

    Defining the site of recurrent disease early after definitive treatment for a localized prostate cancer is a critical issue as it may greatly influence the subsequent therapeutic strategy or patient management. A systematic review of the literature was performed by searching Medline from January 1995 up to January 2011. Electronic searches were limited to the English language, and the keywords prostate cancer, radiotherapy [RT], high intensity focused ultrasound [HIFU], cryotherapy [CRIO], transrectal ultrasound [TRUS], magnetic resonance [MRI], PET/TC, and prostate biopsy were used. Despite the fact that diagnosis of a local recurrence is based on PSA values and kinetics, imaging by means of different techniques may be a prerequisite for effective disease management. Unfortunately, prostate cancer local recurrences are very difficult to detect by TRUS and conventional imaging that have shown limited accuracy at least at early stages. On the contrary, functional and molecular imaging such as dynamic contrast-enhanced MRI (DCE-MRI), and diffusion-weighted imaging (DWI), offers the possibility of imaging molecular or cellular processes of individual tumors. Recently, PET/CT, using 11C-choline, 18F-fluorocholine or 11C-acetate has been successfully proposed in detecting local recurrences as well as distant metastases. Nevertheless, in controversial cases, it is necessary to perform a biopsy of the prostatic fossa or a biopsy of the prostate to assess the presence of a local recurrence under guidance of MRI or TRUS findings. It is likely that imaging will be extensively used in the future to detect and localize prostate cancer local recurrences before salvage treatment.

  14. Surface-based prostate registration with biomechanical regularization

    NASA Astrophysics Data System (ADS)

    van de Ven, Wendy J. M.; Hu, Yipeng; Barentsz, Jelle O.; Karssemeijer, Nico; Barratt, Dean; Huisman, Henkjan J.

    2013-03-01

    Adding MR-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound by using MRUS registration. A common approach is to use surface-based registration. We hypothesize that biomechanical modeling will better control deformation inside the prostate than a regular surface-based registration method. We developed a novel method by extending a surface-based registration with finite element (FE) simulation to better predict internal deformation of the prostate. For each of six patients, a tetrahedral mesh was constructed from the manual prostate segmentation. Next, the internal prostate deformation was simulated using the derived radial surface displacement as boundary condition. The deformation field within the gland was calculated using the predicted FE node displacements and thin-plate spline interpolation. We tested our method on MR guided MR biopsy imaging data, as landmarks can easily be identified on MR images. For evaluation of the registration accuracy we used 45 anatomical landmarks located in all regions of the prostate. Our results show that the median target registration error of a surface-based registration with biomechanical regularization is 1.88 mm, which is significantly different from 2.61 mm without biomechanical regularization. We can conclude that biomechanical FE modeling has the potential to improve the accuracy of multimodal prostate registration when comparing it to regular surface-based registration.

  15. Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys.

    PubMed

    Nyman, R S; Cappelen-Smith, J; al Suhaibani, H; Alfurayh, O; Shakweer, W; Akhtar, M

    1997-05-01

    To compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. A total of 448 biopsies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. The gun-biopsies were performed under real-time ultrasound (US) guidance. The manual technique used US mainly for marking the position of the kidney. There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group. Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.

  16. Prostate cancer diagnosis in a resource-poor setting: the changing role of digital rectal examination.

    PubMed

    Ahmed, Muhammed

    2011-07-01

    We undertook this study in order to determine the current role of digital rectal examination (DRE) in the diagnosis of prostate cancer in a resource-poor setting. The diagnosis of prostate cancer has been revolutionized by the introduction of prostate-specific antigen (PSA), transrectal ultrasound (TRUS) for biopsy guidance and more efficient biopsy equipment, but they are not readily available in most developing countries. This is a prospective study of 131 patients with suspected prostate cancer based on clinical presentation, DRE and elevated PSA. The presence or absence of cancer was confirmed by biopsy and histologic examination. Patients with screen- or incidentally-detected prostate cancer were excluded. The most common symptom was the development of lower urinary tract symptoms (LUTS). All patients had abnormal DRE and indurated prostate was the most frequent finding (50%). The mean PSA was 33.9 ng/mL: of the 131 patients, 80 (61.1%) had a malignant histology following biopsy, 47 (35.9%) were benign and four (3.0%) were prostate intraepithelial neoplasia (PIN). The low specificity of DRE in the diagnosis of prostate cancer requires that it should be combined with other diagnostic modalities such as PSA and TRUS-guided prostate biopsy. Thus government and health-care providers in resource-poor countries must strive to make these facilities available in order to improve prostate cancer diagnosis.

  17. Granulomatous mastitis: changing clinical and imaging features with image-guided biopsy correlation.

    PubMed

    Handa, Priyanka; Leibman, A Jill; Sun, Derek; Abadi, Maria; Goldberg, Aryeh

    2014-10-01

    To review clinical presentation, revisit patient demographics and imaging findings in granulomatous mastitis and determine the optimal biopsy method for diagnosis. A retrospective study was performed to review the clinical presentation, imaging findings and biopsy methods in patients with granulomatous mastitis. Twenty-seven patients with pathology-proven granulomatous mastitis were included. The average age at presentation was 38.0 years (range, 21-73 years). Seven patients were between 48 and 73 years old. Twenty-four patients presented with symptoms and three patients were asymptomatic. Nineteen patients were imaged with mammography demonstrating mammographically occult lesions as the predominant finding. Twenty-six patients were imaged with ultrasound and the most common finding was a mass lesion. Pathological diagnosis was made by image-guided biopsy in 44 % of patients. The imaging features of granulomatous mastitis on mammography are infrequently described. Our study demonstrates that granulomatous mastitis can occur in postmenopausal or asymptomatic patients, although previously reported exclusively in young women with palpable findings. Presentation on mammography as calcifications requiring mammographically guided vacuum-assisted biopsy has not been previously described. The diagnosis of granulomatous mastitis can easily be made by image-guided biopsy and surgical excision should be reserved for definitive treatment. • Characterizes radiographic appearance of granulomatous mastitis in postmenopausal or asymptomatic patients. • Granulomatous mastitis can present exclusively as calcifications on mammography. • The diagnosis of granulomatous mastitis is made by image-guided biopsy techniques.

  18. Update on techniques to prevent infections associated with prostate needle biopsy.

    PubMed

    Fontana, Matteo; Boeri, Luca; Montanari, Emanuele

    2018-04-24

    Postbiopsy infections (PBIs) are among the most common complications associated with transrectal ultrasound-guided prostate biopsy (TRUSPB). This article discusses the pathogenesis of TRUSPB-associated infectious complications and reviews the most recent findings on techniques to prevent PBIs. Risk stratification is a powerful tool for identifying TRUSPB candidates whom warrant additional preventive measures. Bowel preparation with povidone-iodine-based enemas and needle disinfection with formalin solution are simple and attractive strategies, but their effectiveness needs to be thoroughly assessed. Antibiotic prophylaxis represents the mainstay for the prevention of PBIs: the prophylactic regimen must respect the principles of antimicrobial stewardship, and local antibiotic resistance patterns among uropathogens should always be considered. Augmented and targeted antibiotic prophylaxes are powerful options, but their role in current clinical practice has yet to be clarified. The transperineal approach has shown a near-zero rate of PBIs, and should therefore be considered for the highest-risk patients. Several procedures have been introduced to prevent TRUSPB-related infectious complication, but their utility and applicability in the clinical practice has yet to be elucidated. More robust evidence based on randomized control trials is needed to establish the efficacy of these tools in improving patient outcomes.

  19. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara; Ferro, Carlo

    2011-02-15

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsymore » of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.« less

  20. Assessment of long-term outcomes associated with urinary prostate cancer antigen 3 and TMPRSS2:ERG gene fusion at repeat biopsy.

    PubMed

    Merdan, Selin; Tomlins, Scott A; Barnett, Christine L; Morgan, Todd M; Montie, James E; Wei, John T; Denton, Brian T

    2015-11-15

    In men with clinically localized prostate cancer who have undergone at least 1 previous negative biopsy and have elevated serum prostate-specific antigen (PSA) levels, long-term health outcomes associated with the assessment of urinary prostate cancer antigen 3 (PCA3) and the transmembrane protease, serine 2 (TMPRSS2):v-ets erythroblastosis virus E26 oncogene homolog (avian) (ERG) gene fusion (T2:ERG) have not been investigated previously in relation to the decision to recommend a repeat biopsy. The authors performed a decision analysis using a decision tree for men with elevated PSA levels. The probability of cancer was estimated using the Prostate Cancer Prevention Trial Risk Calculator (version 2.0). The use of PSA alone was compared with the use of PCA3 and T2:ERG scores, with each evaluated independently, in combination with PSA to trigger a repeat biopsy. When PCA3 and T2:ERG score evaluations were used, predefined thresholds were established to determine whether the patient should undergo a repeat biopsy. Biopsy outcomes were defined as either positive (with a Gleason score of <7, 7, or >7) or negative. Probabilities and estimates of 10-year overall survival and 15-year cancer-specific survival were derived from previous studies and a literature review. Outcomes were defined as age-dependent and Gleason score-dependent 10-year overall and 15-year cancer-specific survival rates and the percentage of biopsies avoided. Incorporating the PCA3 score (biopsy threshold, 25; generated based on the urine PCA3 level normalized to the amount of PSA messenger RNA) or the T2:ERG score (biopsy threshold, 10; based on the urine T2:ERG level normalized to the amount of PSA messenger RNA) into the decision to recommend repeat biopsy would have avoided 55.4% or 64.7% of repeat biopsies for the base-case patient, respectively, and changes in the 10-year survival rate were only 0.93% or 1.41%, respectively. Multi-way sensitivity analyses suggested that these results were robust

  1. Diagnostic Pathway with Multiparametric Magnetic Resonance Imaging Versus Standard Pathway: Results from a Randomized Prospective Study in Biopsy-naïve Patients with Suspected Prostate Cancer.

    PubMed

    Porpiglia, Francesco; Manfredi, Matteo; Mele, Fabrizio; Cossu, Marco; Bollito, Enrico; Veltri, Andrea; Cirillo, Stefano; Regge, Daniele; Faletti, Riccardo; Passera, Roberto; Fiori, Cristian; De Luca, Stefano

    2017-08-01

    An approach based on multiparametric magnetic resonance imaging (mpMRI) might increase the detection rate (DR) of clinically significant prostate cancer (csPCa). To compare an mpMRI-based pathway with the standard approach for the detection of prostate cancer (PCa) and csPCa. Between November 2014 and April 2016, 212 biopsy-naïve patients with suspected PCa (prostate specific antigen level ≤15 ng/ml and negative digital rectal examination results) were included in this randomized clinical trial. Patients were randomized into a prebiopsy mpMRI group (arm A, n=107) or a standard biopsy (SB) group (arm B, n=105). In arm A, patients with mpMRI evidence of lesions suspected for PCa underwent mpMRI/transrectal ultrasound fusion software-guided targeted biopsy (TB) (n=81). The remaining patients in arm A (n=26) with negative mpMRI results and patients in arm B underwent 12-core SB. The primary end point was comparison of the DR of PCa and csPCa between the two arms of the study; the secondary end point was comparison of the DR between TB and SB. The overall DRs were higher in arm A versus arm B for PCa (50.5% vs 29.5%, respectively; p=0.002) and csPCa (43.9% vs 18.1%, respectively; p<0.001). Concerning the biopsy approach, that is, TB in arm A, SB in arm A, and SB in arm B, the overall DRs were significantly different for PCa (60.5% vs 19.2% vs 29.5%, respectively; p<0.001) and for csPCa (56.8% vs 3.8% vs 18.1%, respectively; p<0.001). The reproducibility of the study could have been affected by the single-center nature. A diagnostic pathway based on mpMRI had a higher DR than the standard pathway in both PCa and csPCa. In this randomized trial, a pathway for the diagnosis of prostate cancer based on multiparametric magnetic resonance imaging (mpMRI) was compared with the standard pathway based on random biopsy. The mpMRI-based pathway had better performance than the standard pathway. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All

  2. The effectiveness of targeted relative to empiric prophylaxis on infectious complications after transrectal ultrasound-guided prostate biopsy: a meta-analysis.

    PubMed

    Scott, Susan; Harris, Patrick N; Williamson, Deborah A; Liss, Michael A; Doi, Suhail A R; Roberts, Matthew J

    2018-07-01

    Rectal culture screening for fluoroquinolone (FQ)-resistant Enterobacteriaceae before transrectal ultrasound guided prostate (TRUSPB) biopsy and targeted antibiotic prophylaxis (TAP) may decrease post-TRUSPB infection rates compared to empiric (EAP) regimens. The objective of this study was to evaluate the effectiveness of targeted relative to empiric prophylaxis regimens on rates of infectious complications after TRUSPB and to determine the baseline prevalence of FQ resistance based on prior rectal swabs. An electronic search within literature databases including EMBASE and Web of Science (all databases) for articles assessing TAP as an approach to TRUSPB prophylaxis was conducted. Quality assessment was performed using the Hoy instrument. Meta-analysis was performed using MetaXL 5.3. From 15 studies (eight retrospective and seven prospective) representing 12,320 participants, infectious complication incidence was 3.4% in EAP and 0.8% in TAP patients. The number needed to treat with TAP to avoid one more infection when compared to the EAP group was 39. Effect sizes were homogeneous. Prevalence of FQ resistance showed low (15%) and high (28%) subgroups, likely due to region of origin (within and outside USA, respectively). Rectal culture prior to TRUSPB and use of TAP adjusts for endemic FQ resistance and is associated with less infectious complications and resulting morbidity when compared to EAP. Overtreatment associated with augmented prophylaxis approaches may be reduced as a result. Further prospective assessment and cost-benefit analyses are required before widespread implementation can be recommended.

  3. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

  4. Longer biopsy cores do not increase prostate cancer detection rate: A large-scale cohort study refuting cut-off values indicated in the literature

    PubMed Central

    Yılmaz, Hasan; Yavuz, Ufuk; Üstüner, Murat; Çiftçi, Seyfettin; Yaşar, Hikmet; Müezzinoğlu, Bahar; Uslubaş, Ali Kemal; Dillioğlugil, Özdal

    2017-01-01

    Objective Only a few papers in the literature aimed to evaluate biopsy core lengths. Additionally, studies evaluated the core length with different approaches. We aimed to determine whether prostate cancer (PCa) detection is affected from core lengths according to three different approaches in a large standard cohort and compare our cut-off values with the published cut-offs. Material and methods We retrospectively analyzed 1,523 initial consecutive transrectal ultrasound-guided 12-core prostate biopsies. Biopsies were evaluated with respect to total core length (total length of each patients’ core) average core length (total core length divided by total number of cores in each patient), and mean core length (mean length of all cores pooled), and compared our cut-off values with the published cut-offs. The prostate volumes were categorized into four groups (<30, 30–59.99, 60–119.99, ≥120 cm3) and PCa detection rates in these categories were examined. Results PCa was found in 41.5% patients. There was no difference between benign and malignant mean core lengths of the pooled cores (p>0.05). Total core length and average core length were not significantly associated with PCa in multivariate logistic regression analyses (p>0.05). The core lengths (mean, average and total core lengths) increased (p<0.001) and PCa rates decreased (p<0.001) steadily with increasing prostate volume categories. PCa percentages decreased in all categories above the utilized cut-offs for mean (p>0.05), average (p<0.05), and total core lengths (p>0.05). Conclusion There was no difference between mean core lengths of benign and malignant cores. Total core length and average core length were not significantly associated with PCa. Contrary to the cut-offs used for mean and average core lengths in the published studies, PCa rates decrease as these core lengths increase. Larger studies are necessary for the determination and acceptance of accurate cut-offs. PMID:28861301

  5. Guided percutaneous fine-needle aspiration biopsy of the liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, C.S.; McLoughlin, M.J.; Tao, L.C.

    1981-04-01

    Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less

  6. Imaging-Guided Core-Needle Breast Biopsy: Impact of Meditation and Music Interventions on Patient Anxiety, Pain, and Fatigue.

    PubMed

    Soo, Mary Scott; Jarosz, Jennifer A; Wren, Anava A; Soo, Adrianne E; Mowery, Yvonne M; Johnson, Karen S; Yoon, Sora C; Kim, Connie; Hwang, E Shelley; Keefe, Francis J; Shelby, Rebecca A

    2016-05-01

    To evaluate the impact of guided meditation and music interventions on patient anxiety, pain, and fatigue during imaging-guided breast biopsy. After giving informed consent, 121 women needing percutaneous imaging-guided breast biopsy were randomized into three groups: (1) guided meditation; (2) music; (3) standard-care control group. During biopsy, the meditation and music groups listened to an audio-recorded, guided, loving-kindness meditation and relaxing music, respectively; the standard-care control group received supportive dialogue from the biopsy team. Immediately before and after biopsy, participants completed questionnaires measuring anxiety (State-Trait Anxiety Inventory Scale), biopsy pain (Brief Pain Inventory), and fatigue (modified Functional Assessment of Chronic Illness Therapy-Fatigue). After biopsy, participants completed questionnaires assessing radiologist-patient communication (modified Questionnaire on the Quality of Physician-Patient Interaction), demographics, and medical history. The meditation and music groups reported significantly greater anxiety reduction (P values < .05) and reduced fatigue after biopsy than the standard-care control group; the standard-care control group reported increased fatigue after biopsy. The meditation group additionally showed significantly lower pain during biopsy, compared with the music group (P = .03). No significant difference in patient-perceived quality of radiologist-patient communication was noted among groups. Listening to guided meditation significantly lowered biopsy pain during imaging-guided breast biopsy; meditation and music reduced patient anxiety and fatigue without compromising radiologist-patient communication. These simple, inexpensive interventions could improve women's experiences during core-needle breast biopsy. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Decreased number of mast cells infiltrating into needle biopsy specimens leads to a better prognosis of prostate cancer

    PubMed Central

    Nonomura, N; Takayama, H; Nishimura, K; Oka, D; Nakai, Y; Shiba, M; Tsujimura, A; Nakayama, M; Aozasa, K; Okuyama, A

    2007-01-01

    Mast cell infiltration is often observed around human tumours. Inflammatory cells such as macrophages, neutrophils and mast cells infiltrating around tumours are known to contribute to tumour growth; however, the clinical significance of mast cell invasion in prostate cancer (PCa) has not been investigated. Mast cell infiltration was evaluated in 104 patients (age range, 45–88 years; median, 72 years), who underwent needle biopsy of the prostate and were confirmed to have PCa. Needle biopsy specimens of prostate were sliced into 5-μm-thick sections and immunostained for mast cells with monoclonal antibody against mast cell-specific tryptase. Mast cells were counted systematically under a microscope (× 400 magnification), and the relations between mast cell numbers and clinicopathologic findings were evaluated. The mast cell count was evaluated for prognostic value by multivariate analysis. Mast cells were immunostained around the cancer foci. The median number of mast cells in each case was 16. The mast cell count was higher around cancer foci in patients with higher Gleason scores than in those with low Gleason scores. The mast cell number correlated well with clinical stage (P<0.001). Prostate-specific antigen-free survival of patients with higher mast cell counts was better than that in patients with lower mast cell counts (P<0.001). Multivariate analysis revealed that mast cell count was a significant prognostic factor (P<0.005). The number of mast cells infiltrating around cancer foci in prostate biopsy specimens can be a significant prognostic factor of PCa. PMID:17848955

  8. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    PubMed

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  9. A 17-gene assay to predict prostate cancer aggressiveness in the context of Gleason grade heterogeneity, tumor multifocality, and biopsy undersampling.

    PubMed

    Klein, Eric A; Cooperberg, Matthew R; Magi-Galluzzi, Cristina; Simko, Jeffry P; Falzarano, Sara M; Maddala, Tara; Chan, June M; Li, Jianbo; Cowan, Janet E; Tsiatis, Athanasios C; Cherbavaz, Diana B; Pelham, Robert J; Tenggara-Hunter, Imelda; Baehner, Frederick L; Knezevic, Dejan; Febbo, Phillip G; Shak, Steven; Kattan, Michael W; Lee, Mark; Carroll, Peter R

    2014-09-01

    Prostate tumor heterogeneity and biopsy undersampling pose challenges to accurate, individualized risk assessment for men with localized disease. To identify and validate a biopsy-based gene expression signature that predicts clinical recurrence, prostate cancer (PCa) death, and adverse pathology. Gene expression was quantified by reverse transcription-polymerase chain reaction for three studies-a discovery prostatectomy study (n=441), a biopsy study (n=167), and a prospectively designed, independent clinical validation study (n=395)-testing retrospectively collected needle biopsies from contemporary (1997-2011) patients with low to intermediate clinical risk who were candidates for active surveillance (AS). The main outcome measures defining aggressive PCa were clinical recurrence, PCa death, and adverse pathology at prostatectomy. Cox proportional hazards regression models were used to evaluate the association between gene expression and time to event end points. Results from the prostatectomy and biopsy studies were used to develop and lock a multigene-expression-based signature, called the Genomic Prostate Score (GPS); in the validation study, logistic regression was used to test the association between the GPS and pathologic stage and grade at prostatectomy. Decision-curve analysis and risk profiles were used together with clinical and pathologic characteristics to evaluate clinical utility. Of the 732 candidate genes analyzed, 288 (39%) were found to predict clinical recurrence despite heterogeneity and multifocality, and 198 (27%) were predictive of aggressive disease after adjustment for prostate-specific antigen, Gleason score, and clinical stage. Further analysis identified 17 genes representing multiple biological pathways that were combined into the GPS algorithm. In the validation study, GPS predicted high-grade (odds ratio [OR] per 20 GPS units: 2.3; 95% confidence interval [CI], 1.5-3.7; p<0.001) and high-stage (OR per 20 GPS units: 1.9; 95% CI, 1

  10. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kuehl, Hilmar; Ladd, Susanne

    2007-09-15

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsiesmore » (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results.« less

  11. Impact of extended prostate biopsy including apical anterior region for cancer detection and prediction of surgical margin status for radical prostatectomy.

    PubMed

    Hashimoto, Kohei; Shinkai, Nobuo; Tanaka, Toshiaki; Masumori, Naoya

    2017-06-01

    We investigated diagnostic yield of initial biopsy and repeated biopsy including apical cores. We investigated 573 consecutive men with PSA of ≤20 ng/ml who underwent prostate biopsy between 2004 and 2013. The initial 14-core biopsy consisted of the sextant type, lateral sites at the base and middle, lateral apices (la) at anterior horn sites, and apical anterior sites (aa). The repeated 18-core biopsy consisted of the initial 14-core biopsy with four transition zone (TZ) sites at the base (tzb) and middle (tzm). Prostate cancer was diagnosed in 178 (38.9%) of 458 men with the initial 14-core biopsy, and 44 (38.3%) of 115 men with the repeated 18-core biopsy. In the initial biopsy setting, the unique cancer detection rate was high in apical sites (apex, la, and aa: 6.2%, 6.2% and 5.1%, respectively). In the repeated setting, it was high in the TZ site in addition to the apical site (apex, la, aa, tzm, and tzb: 6.8%, 6.8%, 11.4%, 9.1% and 11.4%, respectively). The positive SM rate at the apex was higher in patients whose cancer was detected only in sites other than the sextant region than for those in the sextant region (36.4% vs. 14.8%, P = 0.037). The initial 14-core and the repeated 18-core biopsy scheme including apical anterior cores are feasible for prostate cancer detection. We propose that apical biopsy cores can be used to predict not only the existence of cancer but also surgical margin status at the apex. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  13. Comparison of Biochemical Relapse-Free Survival Between Primary Gleason Score 3 and Primary Gleason Score 4 for Biopsy Gleason Score 7 Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burdick, Michael J.; Reddy, Chandana A.; Ulchaker, James

    2009-04-01

    Purpose: To determine whether the primary grade (PG) of biopsy Gleason score (GS) 7 prostate cancer (CaP) was predictive for biochemical relapse-free survival (bRFS). Most of the present data regarding the PG of GS7 CaP refer to surgical specimens. Our goal was to determine whether the biopsy GS used at the time of medical decision making predicted for the biochemical outcome. Methods and Materials: We reviewed the data from 705 patients with biopsy GS7 CaP, from a prospectively maintained database, who had been treated at our institution between September 1996 and March 2005 with radical prostatectomy (n = 310), externalmore » beam radiotherapy (n = 268), or prostate radioactive seed implantation (n = 127). The bRFS rates were estimated using the Kaplan-Meier method. Cox proportional hazards regression analysis was used for univariate and multivariate analyses examining these factors in relation to bRFS: PG of biopsy GS, initial prostate-specific antigen level, clinical T stage, use of androgen deprivation, risk group (high or intermediate), and treatment modality. Results: The 5-year bRFS rate was 78% and 71% (p = 0.0108) for biopsy GS7 PG3 CaP and biopsy GS7 PG4 CaP, respectively. Comparing PG3 and PG4 within treatment modalities, only prostate implantation patients had a significant difference in the 5-year bRFS rate, 88% vs. 76%, respectively (p = 0.0231). On multivariate analysis, the PG of biopsy GS remained an independent predictor of bRFS, with PG3 having better bRFS than PG4 (relative risk, 0.655; 95% confidence interval, 0.472-0.909; p = 0.0113). Conclusion: Biopsy GS7 PG4 CaP carries a worse bRFS than biopsy GS7 PG3 CaP.« less

  14. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    PubMed

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  15. The effectiveness of inking needle core prostate biopsies for preventing patient specimen identification errors: a technique to address Joint Commission patient safety goals in specialty laboratories.

    PubMed

    Raff, Lester J; Engel, George; Beck, Kenneth R; O'Brien, Andrea S; Bauer, Meagan E

    2009-02-01

    The elimination or reduction of medical errors has been a main focus of health care enterprises in the United States since the year 2000. Elimination of errors in patient and specimen identification is a key component of this focus and is the number one goal in the Joint Commission's 2008 National Patient Safety Goals Laboratory Services Program. To evaluate the effectiveness of using permanent inks to maintain specimen identity in sequentially submitted prostate needle biopsies. For a 12-month period, a grossing technician stained each prostate core with permanent ink developed for inking of pathology specimens. A different color was used for each patient, with all the prostate cores from all vials for a particular patient inked with the same color. Five colors were used sequentially: green, blue, yellow, orange, and black. The ink was diluted with distilled water to a consistency that allowed application of a thin, uniform coating of ink along the edges of the prostate core. The time required to ink patient specimens comprising different numbers of vials and prostate biopsies was timed. The number and type of inked specimen discrepancies were evaluated. The identified discrepancy rate for prostate biopsy patients was 0.13%. The discrepancy rate in terms of total number of prostate blocks was 0.014%. Diluted inks adhered to biopsy contours throughout tissue processing. The tissue showed no untoward reactions to the inks. Inking did not affect staining (histochemical or immunohistochemical) or pathologic evaluation. On average, inking prostate needle biopsies increases grossing time by 20%. Inking of all prostate core biopsies with colored inks, in sequential order, is an aid in maintaining specimen identity. It is a simple and effective method of addressing Joint Commission patient safety goals by maintaining specimen identity during processing of similar types of gross specimens. This technique may be applicable in other specialty laboratories and high

  16. A Pitfall in Transrectal Prostate Biopsy: Malakoplakia Evaluation of Two Cases Based on the Literature Review

    PubMed Central

    Solakoglu Kahraman, Dudu; Sayhan, Sevil; Diniz, Gulden; Ayaz, Duygu; Karadeniz, Tugba; Can, Ertan

    2014-01-01

    Malakoplakia is a rarely seen inflammatory condition that is considered to develop secondary to a chronic Escherichia coli infection. Although malakoplakia usually affects the genitourinary tract, it may also be observed in the colon, stomach, lungs, liver, bones, uterus, and skin. Malakoplakia of the genitourinary system usually involves the bladder, whereas it may also affect the prostate along with the bladder. Malakoplakia of the prostate is very rare, and it may be clinically mistaken for prostatic malignancies. Definitive diagnosis is only possible through histopathological examination. This study elaborates on two patients who presented to our hospital in 2013 with high PSA levels. The primary clinical consideration was prostate carcinoma. However, these two cases were diagnosed as malakoplakia based on the results of histopathological analysis of the transrectal prostate biopsy specimen. PMID:24868476

  17. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    PubMed

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  18. Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies: An in-vitro study.

    PubMed

    Lossnitzer, Dirk; Seitz, Sebastian A; Krautz, Birgit; Schnackenburg, Bernhard; André, Florian; Korosoglou, Grigorios; Katus, Hugo A; Steen, Henning

    2015-07-26

    To investigate if magnetic resonance (MR)-guided biopsy can improve the performance and safety of such procedures. A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging (MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance (imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists. MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies.

  19. Computer aided detection in prostate cancer diagnostics: A promising alternative to biopsy? A retrospective study from 104 lesions with histological ground truth.

    PubMed

    Thon, Anika; Teichgräber, Ulf; Tennstedt-Schenk, Cornelia; Hadjidemetriou, Stathis; Winzler, Sven; Malich, Ansgar; Papageorgiou, Ismini

    2017-01-01

    Prostate cancer (PCa) diagnosis by means of multiparametric magnetic resonance imaging (mpMRI) is a current challenge for the development of computer-aided detection (CAD) tools. An innovative CAD-software (Watson Elementary™) was proposed to achieve high sensitivity and specificity, as well as to allege a correlate to Gleason grade. To assess the performance of Watson Elementary™ in automated PCa diagnosis in our hospital´s database of MRI-guided prostate biopsies. The evaluation was retrospective for 104 lesions (47 PCa, 57 benign) from 79, 64.61±6.64 year old patients using 3T T2-weighted imaging, Apparent Diffusion Coefficient (ADC) maps and dynamic contrast enhancement series. Watson Elementary™ utilizes signal intensity, diffusion properties and kinetic profile to compute a proportional Gleason grade predictor, termed Malignancy Attention Index (MAI). The analysis focused on (i) the CAD sensitivity and specificity to classify suspect lesions and (ii) the MAI correlation with the histopathological ground truth. The software revealed a sensitivity of 46.80% for PCa classification. The specificity for PCa was found to be 75.43% with a positive predictive value of 61.11%, a negative predictive value of 63.23% and a false discovery rate of 38.89%. CAD classified PCa and benign lesions with equal probability (P 0.06, χ2 test). Accordingly, receiver operating characteristic analysis suggests a poor predictive value for MAI with an area under curve of 0.65 (P 0.02), which is not superior to the performance of board certified observers. Moreover, MAI revealed no significant correlation with Gleason grade (P 0.60, Pearson´s correlation). The tested CAD software for mpMRI analysis was a weak PCa biomarker in this dataset. Targeted prostate biopsy and histology remains the gold standard for prostate cancer diagnosis.

  20. Computer aided detection in prostate cancer diagnostics: A promising alternative to biopsy? A retrospective study from 104 lesions with histological ground truth

    PubMed Central

    Thon, Anika; Teichgräber, Ulf; Tennstedt-Schenk, Cornelia; Hadjidemetriou, Stathis; Winzler, Sven; Malich, Ansgar

    2017-01-01

    Background Prostate cancer (PCa) diagnosis by means of multiparametric magnetic resonance imaging (mpMRI) is a current challenge for the development of computer-aided detection (CAD) tools. An innovative CAD-software (Watson Elementary™) was proposed to achieve high sensitivity and specificity, as well as to allege a correlate to Gleason grade. Aim/Objective To assess the performance of Watson Elementary™ in automated PCa diagnosis in our hospital´s database of MRI-guided prostate biopsies. Methods The evaluation was retrospective for 104 lesions (47 PCa, 57 benign) from 79, 64.61±6.64 year old patients using 3T T2-weighted imaging, Apparent Diffusion Coefficient (ADC) maps and dynamic contrast enhancement series. Watson Elementary™ utilizes signal intensity, diffusion properties and kinetic profile to compute a proportional Gleason grade predictor, termed Malignancy Attention Index (MAI). The analysis focused on (i) the CAD sensitivity and specificity to classify suspect lesions and (ii) the MAI correlation with the histopathological ground truth. Results The software revealed a sensitivity of 46.80% for PCa classification. The specificity for PCa was found to be 75.43% with a positive predictive value of 61.11%, a negative predictive value of 63.23% and a false discovery rate of 38.89%. CAD classified PCa and benign lesions with equal probability (P 0.06, χ2 test). Accordingly, receiver operating characteristic analysis suggests a poor predictive value for MAI with an area under curve of 0.65 (P 0.02), which is not superior to the performance of board certified observers. Moreover, MAI revealed no significant correlation with Gleason grade (P 0.60, Pearson´s correlation). Conclusion The tested CAD software for mpMRI analysis was a weak PCa biomarker in this dataset. Targeted prostate biopsy and histology remains the gold standard for prostate cancer diagnosis. PMID:29023572

  1. Contemporary prostate biopsy reporting: insights from a survey of clinicians' use of pathology data.

    PubMed

    Varma, Murali; Narahari, Krishna; Mason, Malcolm; Oxley, Jon D; Berney, Daniel M

    2018-05-02

    To determine how clinicians use data in contemporary prostate biopsy reports. A survey was circulated to members of the British Association of Urological Surgeons and the British Uro-oncology Group. Responses were received from 114 respondents (88 urologists, 26 oncologists). Ninety-seven (94%) use the number of positive cores from each side and 43 (42%) use the % number of positive cores. When determining the number and percentage of positive cores, 72 (71%) would not differentiate between targeted and non-targeted samples. If multiple Gleason Scores (GS) were included in a report, 77 (78%) would use the worst GS even if present in a core with very little tumour, 12% would use the global GS and 10% the GS in the core most involved by tumour. Fifty-five (55%) either never or rarely used perineural invasion for patient management. The number of positive cores is an important parameter for patient management but may be difficult to determine in the laboratory due to core fragmentation so the biopsy taker must indicate the number of biopsies obtained. Multiple biopsies taken from a single site are often interpreted by clinicians as separate cores when determining the number of positive cores so pathologists should also report the number of sites positive. Clinicians have a non-uniform approach to the interpretation of multiple GS in prostate biopsy reports so we recommend that pathologists also include a single 'bottom-line' GS for each case to direct the clinician's treatment decision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Interval from prostate biopsy to radical prostatectomy does not affect immediate operative outcomes for open or minimally invasive approach.

    PubMed

    Park, Bumsoo; Choo, Seol Ho; Jeon, Hwang Gyun; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han Yong

    2014-12-01

    Traditionally, urologists recommend an interval of at least 4 weeks after prostate biopsy before radical prostatectomy. The aim of our study was to evaluate whether the interval from prostate biopsy to radical prostatectomy affects immediate operative outcomes, with a focus on differences in surgical approach. The study population of 1,848 radical prostatectomy patients was divided into two groups according to the surgical approach: open or minimally invasive. Open group included perineal and retropubic approach, and minimally invasive group included laparoscopic and robotic approach. The cut-off of the biopsy-to-surgery interval was 4 weeks. Positive surgical margin status, operative time and estimated blood loss were evaluated as endpoint parameters. In the open group, there were significant differences in operative time and estimated blood loss between the <4-week and ≥4-week interval subgroups, but there was no difference in positive margin rate. In the minimally invasive group, there were no differences in the three outcome parameters between the two subgroups. Multivariate analysis revealed that the biopsy-to-surgery interval was not a significant factor affecting immediate operative outcomes in both open and minimally invasive groups, with the exception of the interval ≥4 weeks as a significant factor decreasing operative time in the minimally invasive group. In conclusion, performing open or minimally invasive radical prostatectomy within 4 weeks of prostate biopsy is feasible for both approaches, and is even beneficial for minimally invasive radical prostatectomy to reduce operative time.

  3. Tumor and Plasma Met Levels in Non-Metastatic Prostate Cancer.

    PubMed

    Kaye, Deborah R; Pinto, Peter A; Cecchi, Fabiola; Reilly, Joseph; Semerjian, Alice; Rabe, Daniel C; Gupta, Gopal; Choyke, Peter L; Bottaro, Donald P

    2016-01-01

    To measure Met protein content in prostate biopsies guided by fused magnetic resonance and ultrasound imaging, and to measure soluble Met (sMet) protein concentration in plasma samples from patients presenting evidence of prostate cancer. 345 patients had plasma samples drawn prior to image-guided biopsy of the prostate. Of these, 32% had benign biopsies. Of the 236 that were positive for prostate adenocarcinoma (PCa), 132 treated by total prostatectomy had Gleason scores of 6 (17%), 7, (55%), 8 (16%), or 9-10 (12%). 23% had evidence of local invasion. Plasma samples were also obtained from 80 healthy volunteers. Tissue Met and plasma sMet were measured by two-site immunoassay; values were compared among clinically defined groups using non-parametric statistical tests to determine significant differences or correlations. PCa tumor Met correlated significantly with plasma sMet, but median values were similar among benign and malignant groups. Median plasma sMet values were also similar among those groups, although both medians were significantly above normal. Median Met content in primary PCa tumors and sMet concentrations were independent of Gleason score, final pathologic stage and age. Plasma sMet is not predictive of PCa or its severity in patients with organ-confined or locally invasive disease. Quantitative analysis of Met protein content and activation state in PCa tumor biopsy samples was highly feasible and may have value in follow-up to genomic and/or transcriptomic-based screens that show evidence of oncogenically relevant MET gene features that occur at relatively low frequency in non-metastatic PCa.

  4. Prostate ultrasound--for urologists only?

    PubMed

    Frauscher, Ferdinand; Gradl, Johann; Pallwein, Leo

    2005-11-23

    The value of ultrasound (US) in the diagnosis of prostate cancer has dramatically increased in the past decade. This is mainly related to the increasing incidence of prostate cancer, the most common cancer in men and one of the most important causes of death from cancer in men. The value of conventional gray-scale US for prostate cancer detection has been extensively investigated, and has shown a low sensitivity and specificity. Therefore conventional gray-scale US is mainly used by urologists for guiding systematic prostate biopsies. With the development of new US techniques, such as color and power Doppler US, and the introduction of US contrast agents, the role of US for prostate cancer detection has dramatically changed. Advances in US techniques were introduced to further increase the value of US contrast agents. Although most of these developments in US techniques, which use the interaction of the contrast agent with the transmitted US waves, are very sensitive for the detection of microbubbles, they are mostly unexplored, in particular for prostate applications. Early reports of contrast-enhanced US investigations of blood flow of the prostate have shown that contrast-enhanced US adds important information to the conventional gray-scale US technique. Furthermore, elastography or 'strain imaging' seems to have great potential in prostate cancer detection. Since these new advances in US are very sophisticated and need a long learning curve, radiologists, who are overall better trained with these new US techniques, will play a more important role in prostate cancer diagnosis. Current trends show that these new US techniques may allow for targeted biopsies and therefore replace the current 'gold standard' for prostate cancer detection--the systematic biopsy. Consequently the use of these new US techniques for the detection and clinical staging of prostate cancer is promising. However, future clinical trials will be needed to determine if the promise of these new

  5. Comparison of prostate cancer gene 3 score, prostate health index and percentage free prostate-specific antigen for differentiating histological inflammation from prostate cancer and other non-neoplastic alterations of the prostate at initial biopsy.

    PubMed

    De Luca, Stefano; Passera, Roberto; Bollito, Enrico; Manfredi, Matteo; Scarpa, Roberto Mario; Sottile, Antonino; Randone, Donato Franco; Porpiglia, Francesco

    2014-12-01

    To determine if prostate cancer gene 3 (PCA3) score, Prostate Health Index (PHI), and percent free prostate-specific antigen (%fPSA) may be used to differentiate prostatitis from prostate cancer (PCa), benign prostatic hyperplasia (BPH) and high-grade prostate intraepithelial neoplasia (HG-PIN) in patients with elevated PSA and negative digital rectal examination (DRE). in the present prospective study, 274 patients, undergoing PCA3 score, PHI and %fPSA assessments before initial biopsy, were enrolled. Three multivariate logistic regression models were used to test PCA3 score, PHI and %fPSA as risk factors for prostatitis vs. PCa, vs. BPH, and vs. HG-PIN. All the analyses were performed for the whole patient cohort and for the 'gray zone' of PSA (4-10 ng/ml) cohort (188 individuals). The determinants for prostatitis vs. PCa were PCA3 score, PHI and %fPSA (Odds Ratio [OR]=0.97, 0.96 and 0.94, respectively). Unit increase of PHI was the only risk factor for prostatitis vs. BPH (OR=1.06), and unit increase of PCA3 score for HG-PIN vs. prostatitis (OR=0.98). In the 'gray zone' PSA cohort, the determinants for prostatitis vs. PCa were PCA3 score, PHI and %fPSA (OR=0.96, 0.94 and 0.92, respectively), PCA3 score and PHI for prostatitis vs. BPH (OR=0.96 and 1.08, respectively), and PCA3 score for prostatitis vs. HG-PIN (OR=0.97). The clinical benefit of using PCA3 score and PHI to estimate prostatitis vs. PCa was comparable; even %fPSA had good diagnostic performance, being a faster and cheaper marker. PHI was the only determinant for prostatitis vs. BPH, while PCA3 score for prostatitis vs. HG-PIN. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  6. Clinical utility of the Prostate Health Index (phi) for biopsy decision management in a large group urology practice setting.

    PubMed

    White, Jay; Shenoy, B Vittal; Tutrone, Ronald F; Karsh, Lawrence I; Saltzstein, Daniel R; Harmon, William J; Broyles, Dennis L; Roddy, Tamra E; Lofaro, Lori R; Paoli, Carly J; Denham, Dwight; Reynolds, Mark A

    2018-04-01

    Deciding when to biopsy a man with non-suspicious DRE findings and tPSA in the 4-10 ng/ml range can be challenging, because two-thirds of such biopsies are typically found to be benign. The Prostate Health Index (phi) exhibits significantly improved diagnostic accuracy for prostate cancer detection when compared to tPSA and %fPSA, however only one published study to date has investigated its impact on biopsy decisions in clinical practice. An IRB approved observational study was conducted at four large urology group practices using a physician reported two-part questionnaire. Physician recommendations were recorded before and after receiving the phi test result. A historical control group was queried from each site's electronic medical records for eligible men who were seen by the same participating urologists prior to the implementation of the phi test in their practice. 506 men receiving a phi test were prospectively enrolled and 683 men were identified for the historical control group (without phi). Biopsy and pathological findings were also recorded for both groups. Men receiving a phi test showed a significant reduction in biopsy procedures performed when compared to the historical control group (36.4% vs. 60.3%, respectively, P < 0.0001). Based on questionnaire responses, the phi score impacted the physician's patient management plan in 73% of cases, including biopsy deferrals when the phi score was low, and decisions to perform biopsies when the phi score indicated an intermediate or high probability of prostate cancer (phi ≥36). phi testing significantly impacted the physician's biopsy decision for men with tPSA in the 4-10 ng/ml range and non-suspicious DRE findings. Appropriate utilization of phi resulted in a significant reduction in biopsy procedures performed compared to historical patients seen by the same participating urologists who would have met enrollment eligibility but did not receive a phi test.

  7. The percentage of prostate-specific antigen (PSA) isoform [-2]proPSA and the Prostate Health Index improve the diagnostic accuracy for clinically relevant prostate cancer at initial and repeat biopsy compared with total PSA and percentage free PSA in men aged ≤65 years.

    PubMed

    Boegemann, Martin; Stephan, Carsten; Cammann, Henning; Vincendeau, Sébastien; Houlgatte, Alain; Jung, Klaus; Blanchet, Jean-Sebastien; Semjonow, Axel

    2016-01-01

    To prospectively test the diagnostic accuracy of the percentage of prostate specific antigen (PSA) isoform [-2]proPSA (%p2PSA) and the Prostate Health Index (PHI), and to determine their role for discrimination between significant and insignificant prostate cancer at initial and repeat prostate biopsy in men aged ≤65 years. The diagnostic performance of %p2PSA and PHI were evaluated in a multicentre study. In all, 769 men aged ≤65 years scheduled for initial or repeat prostate biopsy were recruited in four sites based on a total PSA (t-PSA) level of 1.6-8.0 ng/mL World Health Organization (WHO) calibrated (2-10 ng/mL Hybritech-calibrated). Serum samples were measured for the concentration of t-PSA, free PSA (f-PSA) and p2PSA with Beckman Coulter immunoassays on Access-2 or DxI800 instruments. PHI was calculated as (p2PSA/f-PSA × √t-PSA). Uni- and multivariable logistic regression models and an artificial neural network (ANN) were complemented by decision curve analysis (DCA). In univariate analysis %p2PSA and PHI were the best predictors of prostate cancer detection in all patients (area under the curve [AUC] 0.72 and 0.73, respectively), at initial (AUC 0.67 and 0.69) and repeat biopsy (AUC 0.74 and 0.74). t-PSA and %f-PSA performed less accurately for all patients (AUC 0.54 and 0.62). For detection of significant prostate cancer (based on Prostate Cancer Research International Active Surveillance [PRIAS] criteria) the %p2PSA and PHI equally demonstrated best performance (AUC 0.70 and 0.73) compared with t-PSA and %f-PSA (AUC 0.54 and 0.59). In multivariate analysis PHI we added to a base model of age, prostate volume, digital rectal examination, t-PSA and %f-PSA. PHI was strongest in predicting prostate cancer in all patients, at initial and repeat biopsy and for significant prostate cancer (AUC 0.73, 0.68, 0.78 and 0.72, respectively). In DCA for all patients the ANN showed the broadest threshold probability and best net benefit. PHI as single parameter

  8. What Is the Negative Predictive Value of Multiparametric Magnetic Resonance Imaging in Excluding Prostate Cancer at Biopsy? A Systematic Review and Meta-analysis from the European Association of Urology Prostate Cancer Guidelines Panel.

    PubMed

    Moldovan, Paul C; Van den Broeck, Thomas; Sylvester, Richard; Marconi, Lorenzo; Bellmunt, Joaquim; van den Bergh, Roderick C N; Bolla, Michel; Briers, Erik; Cumberbatch, Marcus G; Fossati, Nicola; Gross, Tobias; Henry, Ann M; Joniau, Steven; van der Kwast, Theo H; Matveev, Vsevolod B; van der Poel, Henk G; De Santis, Maria; Schoots, Ivo G; Wiegel, Thomas; Yuan, Cathy Yuhong; Cornford, Philip; Mottet, Nicolas; Lam, Thomas B; Rouvière, Olivier

    2017-08-01

    It remains unclear whether patients with a suspicion of prostate cancer (PCa) and negative multiparametric magnetic resonance imaging (mpMRI) can safely obviate prostate biopsy. To systematically review the literature assessing the negative predictive value (NPV) of mpMRI in patients with a suspicion of PCa. The Embase, Medline, and Cochrane databases were searched up to February 2016. Studies reporting prebiopsy mpMRI results using transrectal or transperineal biopsy as a reference standard were included. We further selected for meta-analysis studies with at least 10-core biopsies as the reference standard, mpMRI comprising at least T2-weighted and diffusion-weighted imaging, positive mpMRI defined as a Prostate Imaging Reporting Data System/Likert score of ≥3/5 or ≥4/5, and results reported at patient level for the detection of overall PCa or clinically significant PCa (csPCa) defined as Gleason ≥7 cancer. A total of 48 studies (9613 patients) were eligible for inclusion. At patient level, the median prevalence was 50.4% (interquartile range [IQR], 36.4-57.7%) for overall cancer and 32.9% (IQR, 28.1-37.2%) for csPCa. The median mpMRI NPV was 82.4% (IQR, 69.0-92.4%) for overall cancer and 88.1% (IQR, 85.7-92.3) for csPCa. NPV significantly decreased when cancer prevalence increased, for overall cancer (r=-0.64, p<0.0001) and csPCa (r=-0.75, p=0.032). Eight studies fulfilled the inclusion criteria for meta-analysis. Seven reported results for overall PCa. When the overall PCa prevalence increased from 30% to 60%, the combined NPV estimates decreased from 88% (95% confidence interval [95% CI], 77-99%) to 67% (95% CI, 56-79%) for a cut-off score of 3/5. Only one study selected for meta-analysis reported results for Gleason ≥7 cancers, with a positive biopsy rate of 29.3%. The corresponding NPV for a cut-off score of ≥3/5 was 87.9%. The NPV of mpMRI varied greatly depending on study design, cancer prevalence, and definitions of positive mpMRI and csPCa. As

  9. Transurethral Drainage of Prostatic Abscess: Points of Technique

    PubMed Central

    El-Shazly, Mohamed; El- Enzy, Nawaf; El-Enzy, Khaled; Yordanov, Encho; Hathout, Badawy; Allam, Adel

    2012-01-01

    Background The incidence of prostatic abscess (PA) has markedly declined with the widespread use of antibiotics and the decreasing incidence of urethral gonococcal infections. Objectives To evaluate different treatment methods for prostatic abscess and to describe technical points that will improve the outcome of transurethral (TUR) drainage of prostatic abscess. Patients and Methods We performed a retrospective study of a series of 11 patients diagnosed with prostatic abscess, who were admitted and treated in Farwaniya Hospital, Kuwait, between February 2008 and November 2010. Drainage was indicated when antibiotic therapy did not cause clinical improvement and after prostatic abscess was confirmed by TRUS (Transrectal ultrasonography) and/or CT computed Tomographyscan. TUR drainage was indicated in 7 cases, ultrasound-guided transrectal drainage was performed in 2 cases, and ultrasound-guided perineal drainage was performed in 2 cases. Results All patients that underwent TUR-drainage had successful outcomes, without the need of secondary treatment or further surgery. Conclusions TUR drainage of a prostatic abscess increases the likelihood of a successful outcome and lowers the incidence of treatment failure or repeated surgery. Less invasive treatment, with perineal or transrectal aspiration, may be preferred as a primary treatment in relatively young patients with localized abscess cavities. PMID:23573466

  10. Does prolonged anti-inflammatory therapy reduce number of unnecessary repeat saturation prostate biopsy?

    PubMed

    Candiano, Giuseppe; Pepe, Pietro; Pietropaolo, Francesco; Aragona, Francesco

    2013-06-24

    The effect of a prolonged oral anti-inflammatory therapy on PSA values in patients with persistent abnormal PSA values after negative prostate biopsy (PBx) was evaluated. From September 2011 to September 2012, 70 patients (medi- an age 62 years), with persistent abnormal PSA values after negative extended PBx, were given an herbal extract with anti-inflammatory activity for 3 months (Lenidase®; 1 tablet daily constituted of baicalina, bromelina and escina). All patients were submitted to prostate biopsy for: abnormal DRE; PSA > 10 ng/mL, PSA values between 4.1-10 or 2.6-4 ng/mL with free/total PSA < 25% and < 20%, respectively. Three months after the end of anti-inflammato- ry therapy all patients were revaluated; indication for repeat saturation biopsy (SPBx) and detection rate for PCa were compared with those previously recorded in our Department using the same inclusions criteria for biopsy. Oral administration of Lenidase® was well tolerated and no side effects were observed; PSA values decreased in 54 (77.8%) out 70 patients with a median PSA reduction of 20.5% (from 8.8 to 7 ng/mL) and remained unchanged in 16 patients (22.2%); the repeat SPBx rate resulted significantly lower (22.8% vs 35.5%; p < 0.05) showing a superimposable detection rate for PCa (3 cases) in comparison with our previous data (18.7% vs 22%). In our preliminary data a prolonged oral anti-inflammatory therapy reduced PSA levels in patients with negative PBx and persistent suspicious for PCa decreasing the indication to perform repeat SPBx (about 30% of the cases).

  11. Lateral decubitus position vs. lithotomy position: which is the best way to minimize patient's pain perception during transrectal prostate biopsy?

    PubMed

    Song, Phil Hyun; Ko, Young Hwii

    2017-01-01

    Considering the distinctive nature in terms of psychological stress and anal tone of position which is generally selected between lithotomy and left lateral decubitus (LLD), we postulated its effect on pain perception during biopsy, and investigated their association. A prospective study for comparison of two biopsy positions which were perform in a different working day was conducted for 208 men (lithotomy position=86, LLD=122). The decision on the position was made solely based on the patient's preference for the biopsy day, and all procedures were performed according to the identical protocol (12-core biopsy with intrarectal lidocaine gel), probe, and needle. The maximal degree of pain during the entire process was assessed using a visual analogue scale (VAS), immediately after biopsy. After propensity matching, a total of 152 patients were finally selected (lithotomy group=76, LLD=76), then peri-biopsy parameters were compared. Between groups, no differences were observed across all variables including age, obesity, prostate volume, serum PSA, international prostate symptom score, and cancer detection rate, except mean (±standard deviation) VAS score (3.89±2.01 vs. 4.58±2.22, p=0.049). VAS score showed significant association solely with patient's position (Pearson's coefficient=-0.165, p=0.042). In multiple linear regression models regarding the effect of clinical variables on VAS score, patient position was a single independent predictor favoring lithotomy position to decrease perceived pain (B=-0.928, p=0.024). These data suggest lithotomy position as a proper way to perform transrectal prostate biopsy with routine use of topical lidocaine gel in comparison with conventional LLD position. Copyright® by the International Brazilian Journal of Urology.

  12. Importance of Local Control in Early-Stage Prostate Cancer: Outcomes of Patients With Positive Post-Radiation Therapy Biopsy Results Treated in RTOG 9408

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu; Hu, Chen; Bahary, Jean-Paul

    Purpose: The purpose of this study was to assess the association between positive post-radiation therapy (RT) biopsy results and subsequent clinical outcomes in males with localized prostate cancer. Methods and Materials: Radiation Therapy Oncology Group study 94-08 analyzed 1979 males with prostate cancer, stage T1b-T2b and prostate-specific antigen concentrations of ≤20 ng/dL, to investigate whether 4 months of total androgen suppression (TAS) added to RT improved survival compared to RT alone. Patients randomized to receive TAS received flutamide with luteinizing hormone releasing hormone (LHRH) agonist. According to protocol, patients without evidence of clinical recurrence or initiation of additional endocrine therapy underwent repeatmore » prostate biopsy 2 years after RT completion. Statistical analysis was performed to evaluate the impact of positive post-RT biopsy results on clinical outcomes. Results: A total of 831 patients underwent post-RT biopsy, 398 were treated with RT alone and 433 with RT plus TAS. Patients with positive post-RT biopsy results had higher rates of biochemical failure (hazard ratio [HR] = 1.7; 95% confidence interval [CI] = 1.3-2.1) and distant metastasis (HR = 2.4; 95% CI = 1.3-4.4) and inferior disease-specific survival (HR = 3.8; 95% CI = 1.9-7.5). Positive biopsy results remained predictive of such outcomes after correction for potential confounders such as Gleason score, tumor stage, and TAS administration. Prior TAS therapy did not prevent elevated risk of adverse outcome in the setting of post-RT positive biopsy results. Patients with Gleason score ≥7 with a positive biopsy result additionally had inferior overall survival compared to those with a negative biopsy result (HR = 1.56; 95% CI = 1.04-2.35). Conclusions: Positive post-RT biopsy is associated with increased rates of distant metastases and inferior disease-specific survival in patients treated with definitive RT and was associated with inferior

  13. Determining the sensitivity of transrectal ultrasonography on a consecutive series of prostate cancers in a clinical and screening setting.

    PubMed

    Ciatto, Stefano; Bonardi, Rita; Lombardi, Claudio; Zappa, Marco; Gervasi, Ginetta

    2002-01-01

    To evaluate the sensitivity at transrectal ultrasonography (TRUS) for prostate cancer. A consecutive series of 170 prostate cancers identified by matching local cancer registry and TRUS archives at the Centro per lo Studio e la Prevenzione Oncologica of Florence. TRUS sensitivity was determined as the ratio of TRUS positive to total prostate cancers occurring at different intervals from TRUS date. Univariate and multivariate analyses of sensitivity determinants were performed. Sensitivity at 6 months, 1, 2 and 3 years after the test was 94.1% (95% CI, 90-98), 89.8% (95% CI, 85-95), 80.4% (95% CI, 74-87) and 74.1% (95% CI, 68-81%), respectively. A higher sensitivity (statistically significant) of TRUS was observed only if digital rectal examination was suspicious, whereas no association to sensitivity was observed for age, prostate-specific antigen or prostate-specific antigen density. The study provided a reliable estimate of TRUS sensitivity, particularly reliable being checked against a cancer registry: observed sensitivity was high, at least of the same magnitude of other cancer screening tests. TRUS, which is known to allow for considerable diagnostic anticipation and is more specific than prostate-specific antigen, might still be considered for its contribution to a screening approach.

  14. Major Bleeding after Percutaneous Image-Guided Biopsies: Frequency, Predictors, and Periprocedural Management

    PubMed Central

    Kennedy, Sean A.; Milovanovic, Lazar; Midia, Mehran

    2015-01-01

    Major bleeding remains an uncommon yet potentially devastating complication following percutaneous image-guided biopsy. This article reviews two cases of major bleeding after percutaneous biopsy and discusses the frequency, predictors, and periprocedural management of major postprocedural bleeding. PMID:25762845

  15. CT Guided Bone Biopsy Using a Battery Powered Intraosseous Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schnapauff, Dirk, E-mail: dirk.schnapauff@charite.de; Marnitz, Tim, E-mail: tim.marnitz@charite.de; Freyhardt, Patrick, E-mail: Patrick.freyhardt@charite.de

    2013-10-15

    Purpose: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. Methods: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. Results: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimenmore » sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 {+-} 6 to 6 {+-} 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 {+-} 87 to 111 {+-} 54 mGy Multiplication-Sign cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. Conclusion: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.« less

  16. The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl; Braak, Sicco J., E-mail: sjbraak@gmail.com

    2016-09-15

    PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented asmore » median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.« less

  17. Percutaneous transgastric computed tomography-guided biopsy of the pancreas using large needles

    PubMed Central

    Tseng, Hsiuo-Shan; Chen, Chia-Yuen; Chan, Wing P; Chiang, Jen-Huey

    2009-01-01

    AIM: To assess the safety, yield and clinical utility of percutaneous transgastric computed tomography (CT)-guided biopsy of pancreatic tumor using large needles, in selected patients. METHODS: We reviewed 34 CT-guided biopsies in patients with pancreas mass, of whom 24 (71%) had a direct path to the mass without passing through a major organ. The needle passed through the liver in one case (3%). Nine passes (26%) were made through the stomach. These nine transgastric biopsies which used a coaxial technique (i.e. a 17-gauge coaxial introducer needle and an 18-gauge biopsy needle) were the basis of this study. Immediate and late follow-up CT images to detect complications were obtained. RESULTS: Tumor tissues were obtained in nine pancreatic biopsies, and histologic specimens for diagnosis were obtained in all cases. One patient, who had a rare sarcomatoid carcinoma, received a second biopsy. One patient had a complication of transient pneumoperitoneum but no subjective complaints. An immediate imaging study and clinical follow-up detected neither hemorrhage nor peritonitis. No delayed procedure-related complication was seen during the survival period of our patients. CONCLUSION: Pancreatic biopsy can be obtained by a transgastric route using a large needle as an alternative method, without complications of peritonitis or bleeding. PMID:20014462

  18. Risks of Being Malignant or High Risk and Their Characteristics in Breast Lesions 20 mm or Larger After Benign Results on Ultrasonography-Guided 14-Gauge Core Needle Biopsy.

    PubMed

    Moon, Hee Jung; Kim, Min Jung; Yoon, Jung Hyun; Kim, Eun-Kyung

    2016-06-01

    The malignancy risk, risk of being high-risk lesions after benign results on ultrasonography-guided 14-gauge core needle biopsies (US-CNBs), and their characteristics in breast lesions of 20 mm or greater were investigated. Eight hundred forty-seven breast lesions with benign results on US-CNB were classified as benign, high risk, and malignant through excision and clinical follow-up. The risks of being malignant or high risk were analyzed in all lesions, lesions 20 to 29 mm, and lesions 30 mm or greater. Their clinicopathological characteristics were evaluated. Of 847, 18 (2.1%) were malignant, 53 (6.3%) were high-risk lesions, and 776 (91.6%) were benign. Of 18 malignancies, 6 (33.3%) were malignant phyllodes tumors and 12 (66.7%) were carcinomas. In benign lesions 20 to 29 mm, risks of being malignant or high risk were 1.6% (9 of 566) and 4.4% (25 of 566). In 281 lesions 30 mm or greater, the risks of being malignant or high risk were 3.2% and 10%. The risk of being high risk in lesions 30 mm or greater was 10%, significantly higher than 4.4% of lesions 20 to 29 mm (P = 0.002). Excision can be considered in lesions measuring 20 mm or larger because of the 2.1% malignancy risk and the 6.3% risk of being high-risk lesions despite benign results on US-CNB. Excision should be considered in lesions measuring 30 mm or larger because of the 3.2% malignancy risk and the 10% risk of being high-risk lesions.

  19. The cost-effectiveness of iodine 131 scintigraphy, ultrasonography, and fine-needle aspiration biopsy in the initial diagnosis of solitary thyroid nodules.

    PubMed

    Khalid, Ayesha N; Hollenbeak, Christopher S; Quraishi, Sadeq A; Fan, Chris Y; Stack, Brendan C

    2006-03-01

    To compare the cost-effectiveness of fine-needle aspiration biopsy, iodine 131 scintigraphy, and ultrasonography for the initial diagnostic workup of a solitary palpable thyroid nodule. A deterministic cost-effectiveness analysis was conducted using a decision tree to model the diagnostic strategies. A single, mid-Atlantic academic medical center. Expected costs, expected number of cases correctly diagnosed, and incremental cost per additional case correctly diagnosed. Relative to the routine use of fine-needle aspiration biopsy, the incremental cost per case correctly diagnosed is 24,554 dollars for the iodine 131 scintigraphy strategy and 1212 dollars for the ultrasound strategy. A diagnostic strategy using initial fine-needle aspiration biopsy for palpable thyroid nodules was found to be cost-effective compared with the other approaches as long as a payor's willingness to pay for an additional correct diagnosis is less than 1212 dollars. Prospective studies are needed to validate these finding in clinical practice.

  20. Repeat prostate biopsies prior to radical prostatectomy do not impact erectile function recovery and mid- to long-term continence.

    PubMed

    Furrer, Marc A; Vilaseca, Antoni; Corradi, Renato B; Boxler, Silvan; Thalmann, George N; Nguyen, Daniel P

    2018-06-01

    A growing number of men undergo repeat biopsies prior to radical prostatectomy for prostate cancer. However, the long-term impact of repeat biopsies on functional outcomes in this patient population remains unelucidated. Thus, we compared functional outcomes between patients who underwent single biopsy versus repeat biopsies before radical prostatectomy. From 1996 to 2015, 1015 consecutive patients underwent radical prostatectomy, and subsequently had urinary continence and erectile function assessed for >2 years follow-up. One-fourth of patients (275; 27%) had ≥2 biopsies before prostatectomy. Logistic regression models tested whether repeat biopsy before prostatectomy predicted continence or erectile function recovery. For the overall cohort, continence rates were 84%, 92%, 96%, and 98% at 3, 6, 12, and 24 months, respectively. Repeat biopsy before prostatectomy was associated with lower continence rate at 3 months compared to single biopsy (P = 0.03); however, no significant differences were observed at 6, 12, or 24 months. In multivariable analyses adjusting for age, body mass index and diabetes/cardiovascular disease/smoking, the association between repeat biopsy and lower likelihood of continence at 3 months remained (odds ratio 0.67, 95% confidence interval 0.47-0.97; P = 0.03). Overall erectile function recovery rates were 16%, 33%, 51%, and 55% at 3, 6, 12, and 24 months, respectively. No difference in erectile function recovery rates was seen at any time point for single biopsy versus repeat biopsy. In multivariable analyses, repeat biopsy was not predictive of erectile function recovery at any time point. Repeat biopsy before radical prostatectomy impairs early continence after surgery. However, erectile function recovery and mid-term to long-term continence are not affected. These data support the current trend towards active surveillance and delayed local treatment in patients with low- to intermediate-risk prostate cancer. © 2018 Wiley

  1. Circulating Magnetic Microbubbles for Localized Real-Time Control of Drug Delivery by Ultrasonography-Guided Magnetic Targeting and Ultrasound

    PubMed Central

    Chertok, Beata; Langer, Robert

    2018-01-01

    Image-guided and target-selective modulation of drug delivery by external physical triggers at the site of pathology has the potential to enable tailored control of drug targeting. Magnetic microbubbles that are responsive to magnetic and acoustic modulation and visible to ultrasonography have been proposed as a means to realize this drug targeting strategy. To comply with this strategy in vivo, magnetic microbubbles must circulate systemically and evade deposition in pulmonary capillaries, while also preserving magnetic and acoustic activities in circulation over time. Unfortunately, challenges in fabricating magnetic microbubbles with such characteristics have limited progress in this field. In this report, we develop magnetic microbubbles (MagMB) that display strong magnetic and acoustic activities, while also preserving the ability to circulate systemically and evade pulmonary entrapment. Methods: We systematically evaluated the characteristics of MagMB including their pharmacokinetics, biodistribution, visibility to ultrasonography and amenability to magneto-acoustic modulation in tumor-bearing mice. We further assessed the applicability of MagMB for ultrasonography-guided control of drug targeting. Results: Following intravenous injection, MagMB exhibited a 17- to 90-fold lower pulmonary entrapment compared to previously reported magnetic microbubbles and mimicked circulation persistence of the clinically utilized Definity microbubbles (>10 min). In addition, MagMB could be accumulated in tumor vasculature by magnetic targeting, monitored by ultrasonography and collapsed by focused ultrasound on demand to activate drug deposition at the target. Furthermore, drug delivery to target tumors could be enhanced by adjusting the magneto-acoustic modulation based on ultrasonographic monitoring of MagMB in real-time. Conclusions: Circulating MagMB in conjunction with ultrasonography-guided magneto-acoustic modulation may provide a strategy for tailored minimally

  2. Endobronchial ultrasonography using a guide sheath technique for diagnosis of peripheral pulmonary lesions

    PubMed Central

    Zhang, Lei; Wu, Hongxu; Wang, Guiqi

    2017-01-01

    Endobronchial ultrasonography using a guide sheath (EBUS-GS) is a novel method used for collecting peripheral pulmonary lesion (PPL) samples. EBUS-GS is performed by introducing a guide sheath-covered miniprobe into the target bronchus and then withdrawing the miniprobe after lesion detection, leaving the guide sheath in situ as a working channel for obtaining lesion samples. EBUS-GS can improve PPL diagnosis rates and be used for obtaining specimens for molecular analysis. In this review, we discuss the clinical applications of EBUS-GS, the factors that affect its diagnostic sensitivity, and potential complications. We also compare EBUS-GS with other available diagnostic techniques and discuss the strengths and limitations of this method. PMID:29063872

  3. Transrectal real-time tissue elastography targeted biopsy coupled with peak strain index improves the detection of clinically important prostate cancer.

    PubMed

    Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi

    2017-07-01

    The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.

  4. The roles of prostate-specific antigen (PSA) density, prostate volume, and their zone-adjusted derivatives in predicting prostate cancer in patients with PSA less than 20.0 ng/mL.

    PubMed

    Shen, P; Zhao, J; Sun, G; Chen, N; Zhang, X; Gui, H; Yang, Y; Liu, J; Shu, K; Wang, Z; Zeng, H

    2017-05-01

    The aim of this study was to develop nomograms for predicting prostate cancer and its zonal location using prostate-specific antigen density, prostate volume, and their zone-adjusted derivatives. A total of 928 consecutive patients with prostate-specific antigen (PSA) less than 20.0 ng/mL, who underwent transrectal ultrasound-guided transperineal 12-core prostate biopsy at West China Hospital between 2011 and 2014, were retrospectively enrolled. The patients were randomly split into training cohort (70%, n = 650) and validation cohort (30%, n = 278). Predicting models and the associated nomograms were built using the training cohort, while the validations of the models were conducted using the validation cohort. Univariate and multivariate logistic regression was performed. Then, new nomograms were generated based on multivariate regression coefficients. The discrimination power and calibration of these nomograms were validated using the area under the ROC curve (AUC) and the calibration curve. The potential clinical effects of these models were also tested using decision curve analysis. In total, 285 (30.7%) patients were diagnosed with prostate cancer. Among them, 131 (14.1%) and 269 (29.0%) had transition zone prostate cancer and peripheral zone prostate cancer. Each of zone-adjusted derivatives-based nomogram had an AUC more than 0.75. All nomograms had higher calibration and much better net benefit than the scenarios in predicting patients with or without different zones prostate cancer. Prostate-specific antigen density, prostate volume, and their zone-adjusted derivatives have important roles in detecting prostate cancer and its zonal location for patients with PSA 2.5-20.0 ng/mL. To the best of our knowledge, this is the first nomogram using these parameters to predict outcomes of 12-core prostate biopsy. These instruments can help clinicians to increase the accuracy of prostate cancer screening and to avoid unnecessary prostate biopsy. © 2017

  5. Role of Surveillance Biopsy with No Cancer as a Prognostic Marker for Reclassification: Results from the Canary Prostate Active Surveillance Study.

    PubMed

    Kearns, James T; Faino, Anna V; Newcomb, Lisa F; Brooks, James D; Carroll, Peter R; Dash, Atreya; Ellis, William J; Fabrizio, Michael; Gleave, Martin E; Morgan, Todd M; Nelson, Peter S; Thompson, Ian M; Wagner, Andrew A; Zheng, Yingye; Lin, Daniel W

    2018-05-01

    Many patients who are on active surveillance (AS) for prostate cancer will have surveillance prostate needle biopsies (PNBs) without any cancer evident. To define the association between negative surveillance PNBs and risk of reclassification on AS. All men were enrolled in the Canary Prostate Active Surveillance Study (PASS) between 2008 and 2016. Men were included if they had Gleason ≤3+4 prostate cancer and <34% core involvement ratio at diagnosis. Men were prescribed surveillance PNBs at 12 and 24 mo after diagnosis and then every 24 mo. Reclassification was defined as an increase in Gleason grade and/or an increase in the ratio of biopsy cores to cancer to ≥34%. PNB outcomes were defined as follows: (1) no cancer on biopsy, (2) cancer without reclassification, or (3) reclassification. Kaplan-Meier and Cox proportional hazard models were performed to assess the risk of reclassification. A total of 657 men met inclusion criteria. On first surveillance PNB, 214 (32%) had no cancer, 282 (43%) had cancer but no reclassification, and 161 (25%) reclassified. Among those who did not reclassify, 313 had a second PNB. On second PNB, 120 (38%) had no cancer, 139 (44%) had cancer but no reclassification, and 54 (17%) reclassified. In a multivariable analysis, significant predictors of decreased future reclassification after the first PNB were no cancer on PNB (hazard ratio [HR]=0.50, p=0.008), lower serum prostate-specific antigen, larger prostate size, and lower body mass index. A finding of no cancer on the second PNB was also associated with significantly decreased future reclassification in a multivariable analysis (HR=0.15, p=0.003), regardless of the first PNB result. The major limitation of this study is a relatively small number of patients with long-term follow-up. Men who have a surveillance PNB with no evidence of cancer are significantly less likely to reclassify on AS in the PASS cohort. These findings have implications for tailoring AS protocols. Men on

  6. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de; Fabel, Michael; Bolte, Hendrik

    2010-08-15

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helicallymore » bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.« less

  7. Is it time to perform only MRI targeted cores? Our experience in 1032 men submitted to prostate biopsy.

    PubMed

    Pepe, Pietro; Garufi, Antonio; Priolo, Gian Domenico; Galia, Antonio; Fraggetta, Filippo; Pennisi, Michele

    2018-04-18

    Diagnostic accuracy of mpMRI (multiparametric magnetic resonance imaging) in the diagnosis of clinically significant prostate cancer (csPCa) has been evaluated and compared with transperineal saturation prostate biopsy (SPBx). From January 2011 to Febraury 2018 1032 men (median age 63 years) with median PSA of 8.6 ng/ml underwent repeat SPBx (reference test) for the suspicion of cancer. All the patients underwent 3.0 Tesla pelvic mpMRI before SPBx and the lesions with PI-RADS (Prostate Imaging-Reporting and Data System) score ≥ 3 were submitted to additional targeted fusion prostate biopsy (TPBx). A T1c PCa was found in 372/1032 (36%) patients and 272 (73.1%) of them were classified as csPCa. SPBx vs. TPBx PI-RADS > 3 vs. TPBx PI-RADS > 4 diagnosed 95.6 vs. 83.8 vs. 60.3% (p < 0.0001) of the csPCa; in detail, SPBx missed 12/272 (4.5%) csPCa vs. 44/272 (16.2%) and 108/272 (39.7%) missed by TPBx PI-RADS > 3 and TPBx PI-RADS > 4 (p < 0.0001), respectively. The use of mpMRI as "a triage test" would have spared 49.3% vs. 73.6% using as cut-off a PI-RADS > 3 vs PI-RADS > 4, respectively. MpMRI could significantly reduce the number of unnecessary repeat prostate biopsies (about 50% of the cases using a PI-RADS score > 3); at the same time, the patients should be informed of the false-negative rate for csPCa of TPBx for PI-RADS > 3 (16.2%) or > 4 (39.7%). Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. Diagnostic utility of alpha-methylacyl CoA racemase (P504S) on prostate needle biopsy.

    PubMed

    Jiang, Zhong; Woda, Bruce A

    2004-11-01

    Alpha-methylacyl CoA racemase (AMACR), also known as P504S, was identified by the analysis of cDNA library subtraction in conjunction with high throughput microarray screening from prostate tissue and has been proven to be one of the very few biomarkers that can distinguish cancer from benign cells with high sensitivity and specificity for prostate carcinoma. It is a successful example of the translation of molecular findings into clinical practice. This review focuses on the study of AMACR (P504S) expression in small focal prostate cancer and atypical small acinar proliferation (ASAP) on needle biopsies and emphasizes the utility of AMACR (P504S) in routine surgical pathology practice. We also discuss the potential pitfalls and caveats in the interpretation of immunostaining results.

  9. Commentary on "Asymptomatic prostatic inflammation in men with clinical BPH and erectile dysfunction affects the positive predictive value of prostate-specific antigen." Agnihotri S, Mittal RD, Kapoor R, Mandhani A, Department of Urology & Renal Transplantation, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, India.: Urol Oncol 2014; [Epub ahead of print]. doi: 10.1016/j.urolonc.2014.03.004.

    PubMed

    Pu, Chunxiao; Wang, Jia; Wei, Qiang; Han, Ping

    2015-02-01

    To test the hypothesis that sexual dysfunction in elderly men with benign prostatic hyperplasia leads to prostatic inflammation, diagnosed by prostatic fluid interleukin-8 (IL-8), which lowers the positive predictive value of prostate-specific antigen (PSA). Overall, 160 men with lower urinary tract symptoms between 50 and 75 years of age with an elevated PSA level of more than 4ng/ml with normal digital rectal examination and 50 age-matched controls with normal PSA level were prospectively evaluated for prostatic fluid IL-8 levels. Erectile dysfunction was measured by self-administered questionnaire of the Sexual Health Inventory for Men. Total and free serum PSA levels and IL-8 in prostatic fluid were measured 6 to 8 weeks after a course of 400mg of ofloxacin and 20mg of piroxicam given daily for 2 weeks. Transrectal ultrasonography-guided biopsy was done only when PSA level did not decrease less than 4ng/ml. Mean ages of patients and controls were 63.18 (standard deviation [SD]±7.10) and 60.18 (SD+6.02) years, respectively. Mean concentration of IL-8 in prostatic fluid of the patients was significantly higher, i.e., 6,678pg/ml (SD±1,985.7) than in control, i.e., 1,543pg/ml (SD±375.7) (P<0.001). Following anti-inflammatory treatment, there was a significant decrease in the mean level of IL-8 from baseline to 5,622pg/ml (SD±1,870.66) (P<0.001). Corresponding to this, a significant decrease was noted in total PSA levels to less than 4ng/ml in 105 (65.62%) patients. Men with the highest levels of IL-8 had a greater degree of erectile dysfunction. Men with symptomatic benign prostatic hyperplasia and erectile dysfunction had significant inflammation of the prostate to cause spurious rise in PSA level resulting in an unnecessary biopsy. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. De novo steroid biosynthesis in human prostate cell lines and biopsies.

    PubMed

    Sakai, Monica; Martinez-Arguelles, Daniel B; Aprikian, Armen G; Magliocco, Anthony M; Papadopoulos, Vassilios

    2016-05-01

    Intratumoral androgen formation may be a factor in the development of prostate cancer (PCa), particularly castration-resistant prostate cancer (CRPC). To evaluate the ability of the human prostate to synthesize de novo steroids, we examined the expression of key enzymes and proteins involved in steroid biosynthesis and metabolism. Using TissueScan™ Cancer qPCR Arrays and quantitative RT-PCR, we performed comparative gene expression analyses between various prostate cell lines and biopsies, including normal, hyperplastic, cancerous, and androgen-deprived prostate cells lines, as well as normal, benign prostate hyperplasia (BPH), PCa, and CRPC human specimens. These studies were complemented with steroid biosynthesis studies in normal and BPH cells. Normal human prostate WPMY-1 and WPE1-NA22, benign prostate hyperplasia BPH-1, and cancer PC-3, LNCaP, and VCaP cell lines, as well as normal, BPH, PCa, and CRPC specimens, were used. Although all cell lines express mRNA encoding for hydroxymethylglutaryl-CoA reductase (HMGCR), the mitochondrial translocator protein TSPO and cholesterol side chain cleavage enzyme CYP11A1 were only observed in WPMY-1, BPH-1, and LNCaP cells. HSD3B1, HSD3B2, and CYP17A1 are involved in androgen formation and were not found in most cell lines. WPE1-NA22 and BPH-1 cells were unable to synthesize de novo steroids from mevalonate. Moreover, androgen-deprived cells did not have alterations in the expression of enzymes that could lead to de novo steroid formation. All prostate specimens expressed TSPO and CYP11A1. HSD3B1/2, CYP17A1, HSD17B5, and CYP19A1 mRNA expression was distinct to the profile observed in cells lines. The majority of BPH (90.9%) and PCa (83.1%) specimens contained CYP17A1, compared to control (normal) specimens (46.7%). BPH (82%), PCa (59%), normal (40%), and CRPC (34%) specimens expressed the four key enzymes that metabolize cholesterol to androgens. These studies question the use of prostate cell lines to study steroid

  11. Prostate cancer prediction using the random forest algorithm that takes into account transrectal ultrasound findings, age, and serum levels of prostate-specific antigen.

    PubMed

    Xiao, Li-Hong; Chen, Pei-Ran; Gou, Zhong-Ping; Li, Yong-Zhong; Li, Mei; Xiang, Liang-Cheng; Feng, Ping

    2017-01-01

    The aim of this study is to evaluate the ability of the random forest algorithm that combines data on transrectal ultrasound findings, age, and serum levels of prostate-specific antigen to predict prostate carcinoma. Clinico-demographic data were analyzed for 941 patients with prostate diseases treated at our hospital, including age, serum prostate-specific antigen levels, transrectal ultrasound findings, and pathology diagnosis based on ultrasound-guided needle biopsy of the prostate. These data were compared between patients with and without prostate cancer using the Chi-square test, and then entered into the random forest model to predict diagnosis. Patients with and without prostate cancer differed significantly in age and serum prostate-specific antigen levels (P < 0.001), as well as in all transrectal ultrasound characteristics (P < 0.05) except uneven echo (P = 0.609). The random forest model based on age, prostate-specific antigen and ultrasound predicted prostate cancer with an accuracy of 83.10%, sensitivity of 65.64%, and specificity of 93.83%. Positive predictive value was 86.72%, and negative predictive value was 81.64%. By integrating age, prostate-specific antigen levels and transrectal ultrasound findings, the random forest algorithm shows better diagnostic performance for prostate cancer than either diagnostic indicator on its own. This algorithm may help improve diagnosis of the disease by identifying patients at high risk for biopsy.

  12. Computed Tomography-Guided Biopsy for Potts Disease: An Institutional Experience from an Endemic Developing Country

    PubMed Central

    Waqas, Muhammad; Qadeer, Mohsin; Faiz, Faizuddin; Alvi, Mohammad Ali

    2015-01-01

    Study Design A retrospective chart review. Purpose In endemic resource poor countries like Pakistan, most patients are diagnosed and treated for Potts disease on clinical and radiological grounds without a routine biopsy. The purpose of this study was to evaluate the use and effect of computed tomography (CT)-guided biopsy in the management of Potts disease since the technique is becoming increasingly available. Overview of Literature CT-guided biopsy of spinal lesions is routinely performed. Literature on the utility of the technique in endemic resource poor countries is little. Methods This study was conducted at the Neurosurgery section of Aga Khan University Hospital Karachi. All the patients with suspected Potts disease who underwent CT-guided biopsy during the 7 year period from 2007 to 2013 were included in this study. Details of the procedure, histopathology and microbiology were recorded. Results One hundred and seventy-eight patients were treated for suspected Potts disease during the study period. CT-guided biopsies of the spinal lesions were performed in 91 patients (51.12%). Of the 91 procedures, 22 (24.2%) were inconclusive because of inadequate sample (10), normal tissue (6) or reactive tissue (6). Sixty-nine biopsies were positive (75.8%). Granulomatous inflammation was seen in 58 patients (84.05%), positive acid-fast bacillus (AFB) smear in 4 (5.7%) and positive AFB culture in 12 patients (17.3%). All 91 cases in which CT-guided biopsy was performed responded positively to antituberculosis therapy (ATT). Conclusions 75.8% of the specimens yielded positive diagnoses. Granulomatous inflammation on histopathology was the commonest diagnostic feature. In this series, the rates of positive AFB smear and culture were low compared to previous literature. PMID:26097654

  13. Intraoperative Magnetic Resonance Imaging-Guided Biopsy in the Diagnosis of Suprasellar Langerhans Cell Histiocytosis.

    PubMed

    Carroll, Kate T; Lochte, Bryson C; Chen, James Y; Snyder, Vivian S; Carter, Bob S; Chen, Clark C

    2018-04-01

    Magnetic resonance imaging (MRI)-guided biopsy is an emerging diagnostic technique that holds great promise for otherwise difficult to access neuroanatomy. Here we describe MRI-guided biopsy of a suprasellar lesion located posterior and superior to the pituitary stalk. The approach was implemented successfully in a 38-year-old woman who had developed progressive visual deterioration. Intraoperative MRI revealed the need for trajectory adjustment due to an unintended, minor deviation in the burr hole entry point, demonstrating the benefit of an MRI-guided approach. Langerhans cell histiocytosis was diagnosed after biopsy, and the lesion regressed after cladribine treatment. Technical nuances of the case are reviewed in the context of the available literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. State-of-the-art uroradiologic imaging in the diagnosis of prostate cancer.

    PubMed

    Heijmink, Stijn W T P J; Fütterer, Jurgen J; Strum, Stephen S; Oyen, Wim J G; Frauscher, Ferdinand; Witjes, J Alfred; Barentsz, Jelle O

    2011-06-01

    In the diagnostic process of prostate cancer, several radiologic imaging modalities significantly contribute to the detection and localization of the disease. These range from transrectal ultrasound (TRUS) and magnetic resonance imaging (MRI) to positron emission tomography (PET). Within this review, after evaluation of the literature, we will discuss the advantages and disadvantages of these imaging modalities in clarifying the patient's clinical status as to whether he has prostate cancer or not and if so, where it is located, so that therapy appropriate to the patient's disease may be administered. TRUS, specifically with the usage of intravenous contrast agents, provides an excellent way of directing biopsy towards suspicious areas within the prostate in the general (screening) population. MRI using functional imaging techniques allows for highly accurate detection and localization, particularly in patients with prior negative ultrasound guided biopsies. A promising new development is the performance of biopsy within the magnetic resonance scanner. Subsequently, a proposal for optimal use of radiologic imaging is presented and compared with the European and American urological guidelines on prostate cancer.

  15. Addition of Ceftriaxone and Amikacin to a Ciprofloxacin plus Metronidazole Regimen for Preventing Infectious Complications of Transrectal Ultrasound-Guided Prostate Biopsy: A Randomized Controlled Trial

    PubMed Central

    Izadpanahi, Mohammad-Hossein; Majidi, Seyed Mahmood; Khorrami, Mohammad-Hatef; Mohammadi-Sichani, Mehrdad

    2017-01-01

    Background. The objective of this study was to evaluate the efficacy of adding single doses of ceftriaxone and amikacin to a ciprofloxacin plus metronidazole regimen on the reduction of infectious complications following transrectal ultrasound-guided prostate biopsy (TRUS Bx). Materials and Methods. Four hundred and fifty patients who were candidates for TRUS Bx were divided into two groups of 225 each. The control group received ciprofloxacin 500 mg orally every 12 hours together with metronidazole 500 mg orally every 8 hours from the day prior to the procedure until the fifth postoperative day. In the second group, single doses of ceftriaxone 1 g by intravenous infusion and amikacin 5 mg/kg intramuscularly were administered 30–60 minutes before TRUS Bx in addition to the oral antimicrobials described for group 1. The incidence of infection was compared between the groups. Results. The incidence of infectious complications in the intervention group was significantly lower than that in the control group (4.6% versus 0.9%, p = 0.017). Conclusion. The addition of single doses of intramuscular amikacin and intravenously infused ceftriaxone to our prophylactic regimen of ciprofloxacin plus metronidazole resulted in a statistically significant reduction of infectious complications following TRUS Bx. PMID:28167960

  16. Addition of Ceftriaxone and Amikacin to a Ciprofloxacin plus Metronidazole Regimen for Preventing Infectious Complications of Transrectal Ultrasound-Guided Prostate Biopsy: A Randomized Controlled Trial.

    PubMed

    Izadpanahi, Mohammad-Hossein; Nouri-Mahdavi, Kia; Majidi, Seyed Mahmood; Khorrami, Mohammad-Hatef; Alizadeh, Farshid; Mohammadi-Sichani, Mehrdad

    2017-01-01

    Background. The objective of this study was to evaluate the efficacy of adding single doses of ceftriaxone and amikacin to a ciprofloxacin plus metronidazole regimen on the reduction of infectious complications following transrectal ultrasound-guided prostate biopsy (TRUS Bx). Materials and Methods. Four hundred and fifty patients who were candidates for TRUS Bx were divided into two groups of 225 each. The control group received ciprofloxacin 500 mg orally every 12 hours together with metronidazole 500 mg orally every 8 hours from the day prior to the procedure until the fifth postoperative day. In the second group, single doses of ceftriaxone 1 g by intravenous infusion and amikacin 5 mg/kg intramuscularly were administered 30-60 minutes before TRUS Bx in addition to the oral antimicrobials described for group 1. The incidence of infection was compared between the groups. Results. The incidence of infectious complications in the intervention group was significantly lower than that in the control group (4.6% versus 0.9%, p = 0.017). Conclusion. The addition of single doses of intramuscular amikacin and intravenously infused ceftriaxone to our prophylactic regimen of ciprofloxacin plus metronidazole resulted in a statistically significant reduction of infectious complications following TRUS Bx.

  17. Sampling of the anterior apical region results in increased cancer detection and upgrading in transrectal repeat saturation biopsy of the prostate.

    PubMed

    Seles, Maximilian; Gutschi, Thomas; Mayrhofer, Katrin; Fischereder, Katja; Ehrlich, Georg; Gallé, Guenter; Gutschi, Stefan; Pachernegg, Oliver; Pummer, Karl; Augustin, Herbert

    2016-04-01

    To evaluate whether biopsy cores taken via a transrectal approach from the anterior apical region of the prostate in a repeat-biopsy population can result in an increased overall cancer detection rate and in more accurate assessment of the Gleason score. The study was a prospective, randomised (end-fire vs side-fire ultrasound probe) evaluation of 288 men by repeat transrectal saturation biopsy with 28 cores taken from the transition zone, base, mid-lobar, anterior and the anterior apical region located ventro-laterally to the urethra of the peripheral zone. The overall prostate cancer detection rate was 44.4%. Improvement of the overall detection rate by 7.8% could be achieved with additional biopsies of the anterior apical region. Two tumours featuring a Gleason score 7 could only be detected in the anterior apical region. In three cases (2.34%) Gleason score upgrading was achieved by separate analysis of each positive core of the anterior apical region. A five-fold higher cancer detection rate in the anterior apical region compared with the transition zone could be shown. Sampling of the anterior apical region results in higher overall cancer detection rate in repeat transrectal saturation biopsies of the prostate. Specimens from this region can detect clinically significant cancer, improve accuracy of the Gleason Scoring and therefore may alter therapy. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  18. The Diagnostic Performance of Multiparametric Magnetic Resonance Imaging to Detect Significant Prostate Cancer.

    PubMed

    Thompson, J E; van Leeuwen, P J; Moses, D; Shnier, R; Brenner, P; Delprado, W; Pulbrook, M; Böhm, M; Haynes, A M; Hayen, A; Stricker, P D

    2016-05-01

    We assess the accuracy of multiparametric magnetic resonance imaging for significant prostate cancer detection before diagnostic biopsy in men with an abnormal prostate specific antigen/digital rectal examination. A total of 388 men underwent multiparametric magnetic resonance imaging, including T2-weighted, diffusion weighted and dynamic contrast enhanced imaging before biopsy. Two radiologists used PI-RADS to allocate a score of 1 to 5 for suspicion of significant prostate cancer (Gleason 7 with more than 5% grade 4). PI-RADS 3 to 5 was considered positive. Transperineal template guided mapping biopsy of 18 regions (median 30 cores) was performed with additional manually directed cores from magnetic resonance imaging positive regions. The anatomical location, size and grade of individual cancer areas in the biopsy regions (18) as the primary outcome and in prostatectomy specimens (117) as the secondary outcome were correlated to the magnetic resonance imaging positive regions. Of the 388 men who were enrolled in the study 344 were analyzed. Multiparametric magnetic resonance imaging was positive in 77.0% of patients, 62.5% had prostate cancer and 41.6% had significant prostate cancer. The detection of significant prostate cancer by multiparametric magnetic resonance imaging had a sensitivity of 96%, specificity of 36%, negative predictive value of 92% and positive predictive value of 52%. Adding PI-RADS to the multivariate model, including prostate specific antigen, digital rectal examination, prostate volume and age, improved the AUC from 0.776 to 0.879 (p <0.001). Anatomical concordance analysis showed a low mismatch between the magnetic resonance imaging positive regions and biopsy positive regions (4 [2.9%]), and the significant prostate cancer area in the radical prostatectomy specimen (3 [3.3%]). In men with an abnormal prostate specific antigen/digital rectal examination, multiparametric magnetic resonance imaging detected significant prostate cancer

  19. Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Surry, K. J. M.; Mills, G. R.; Bevan, K.

    2007-11-15

    Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM andmore » US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target

  20. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    PubMed

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  1. Pathological upgrading in prostate cancer patients eligible for active surveillance: Does prostate-specific antigen density matter?

    PubMed

    Jin, Byung-Soo; Kang, Seok-Hyun; Kim, Duk-Yoon; Oh, Hoon-Gyu; Kim, Chun-Il; Moon, Gi-Hak; Kwon, Tae-Gyun; Park, Jae-Shin

    2015-09-01

    To evaluate prospectively the role of prostate-specific antigen (PSA) density in predicting Gleason score upgrading in prostate cancer patients eligible for active surveillance (T1/T2, biopsy Gleason score≤6, PSA≤10 ng/mL, and ≤2 positive biopsy cores). Between January 2010 and November 2013, among patients who underwent greater than 10-core transrectal ultrasound-guided biopsy, 60 patients eligible for active surveillance underwent radical prostatectomy. By use of the modified Gleason criteria, the tumor grade of the surgical specimens was examined and compared with the biopsy results. Tumor upgrading occurred in 24 patients (40.0%). Extracapsular disease and positive surgical margins were found in 6 patients (10.0%) and 8 patients (17.30%), respectively. A statistically significant correlation between PSA density and postoperative upgrading was found (p=0.030); this was in contrast with the other studied parameters, which failed to reach significance, including PSA, prostate volume, number of biopsy cores, and number of positive cores. Tumor upgrading was also highly associated with extracapsular cancer extension (p=0.000). The estimated optimal cutoff value of PSA density was 0.13 ng/mL(2), obtained by receiver operating characteristic analysis (area under the curve=0.66; p=0.020; 95% confidence interval, 0.53-0.78). PSA density is a strong predictor of Gleason score upgrading after radical prostatectomy in patients eligible for active surveillance. Because tumor upgrading increases the potential for postoperative pathological adverse findings and prognosis, PSA density should be considered when treating and consulting patients eligible for active surveillance.

  2. Impact of PSA density of transition zone as a potential parameter in reducing the number of unnecessary prostate biopsies in patients with psa levels between 2.6 and 10.0 ng/mL.

    PubMed

    Castro, Hugo A Socrates; Iared, Wagner; Santos, José Eduardo Mourão; Solha, Raphael Sandes; Shigueoka, David Carlos; Ajzen, Sergio Aron

    2018-04-10

    To assess the accuracy of prostate-specific antigen (PSA) adjusted for the transition zone volume (PSATZ) in predicting prostate cancer by comparing the ability of several PSA parameters in predicting prostate cancer in men with intermediate PSA levels of 2.6 - 10.0 ng/mL and its ability to reduce unnecessary biopsies. This study included 656 patients referred for prostate biopsy who had a serum PSA of 2.6 - 10.0 ng/mL. Total prostate and transition zone volumes were measured by transrectal ultrasound using the prolate ellipsoid method. The clinical values of PSA, free-to-total (F/T) ratio, PSA density (PSAD) and PSATZ for the detection of prostate cancer were calculated and statistical comparisons between biopsy-positive (cancer) and biopsy-negative (benign) were conducted. Cancer was detected in 172 patients (26.2%). Mean PSA, PSATZ, PSAD and F/T ratio were 7.5 ng/mL, 0.68 ng/mL/cc. 0.25 ng/mL/cc and 0.14 in patients with prostate cancer and 6.29 ng/mL, 0.30 ng/mL/cc, 0.16 ng/mL/cc and 0.22 in patients with benign biopsies, respectively. ROC curves analysis demonstrated that PSATZ had a higher area under curve (0,838) than F/T ratio (0,806) (P<0.001) and PSAD (0,806) (P<0.001). With a cut-off value of 0.22 ng/mL/cc, PSATZ had 100% of sensitivity and could have prevented 24% of unnecessary biopsies. PSATZ may be useful in enhancing the specificity of serum PSA. Compared to other PSA related parameters, it was better in differentiating between prostate cancer and benign prostatic enlargement. Also, PSATZ could reduce a significant number of unnecessary biopsies. Copyright® by the International Brazilian Journal of Urology.

  3. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy.

    PubMed

    Naqvi, Hanna; Edhi, Muhammad Muzzammil; Aslam, Hafiz Muhammad; Faridi, Naveen

    2013-02-12

    Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis.

  4. Primary Neuroendocrine Breast Carcinoma in a 13-Year-Old Girl: Ultrasonography and Pathology Findings

    PubMed Central

    Folligan, Koué; Sabi, Akomola; Sonhaye, Lantam; Boumé, Azanledji; Bassowa, Akila; Adani-Ifé, Solange; Napo-Koura, Gado

    2017-01-01

    Neuroendocrine carcinoma (NEC) of the breast is a rare disease and has been scarcely reported by African authors. The authors report a case of breast NEC in a 13-year-old African girl initially diagnosed as an atypical adenofibroma by ultrasonography. Ultrasound-guided biopsy and conventional histological examination indicated two potential diagnoses: primary malignant non-Hodgkin's lymphoma and undifferentiated carcinoma. According to immunohistochemistry performed on paraffin blocks in France, infiltrating ductal carcinoma with a strong neuroendocrine component was confirmed by CD56, CD57, and chromogranin A markers. PMID:29082059

  5. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    PubMed Central

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  6. Combined Clinical Parameters and Multiparametric Magnetic Resonance Imaging for Advanced Risk Modeling of Prostate Cancer-Patient-tailored Risk Stratification Can Reduce Unnecessary Biopsies.

    PubMed

    Radtke, Jan Philipp; Wiesenfarth, Manuel; Kesch, Claudia; Freitag, Martin T; Alt, Celine D; Celik, Kamil; Distler, Florian; Roth, Wilfried; Wieczorek, Kathrin; Stock, Christian; Duensing, Stefan; Roethke, Matthias C; Teber, Dogu; Schlemmer, Heinz-Peter; Hohenfellner, Markus; Bonekamp, David; Hadaschik, Boris A

    2017-12-01

    Multiparametric magnetic resonance imaging (mpMRI) is gaining widespread acceptance in prostate cancer (PC) diagnosis and improves significant PC (sPC; Gleason score≥3+4) detection. Decision making based on European Randomised Study of Screening for PC (ERSPC) risk-calculator (RC) parameters may overcome prostate-specific antigen (PSA) limitations. We added pre-biopsy mpMRI to ERSPC-RC parameters and developed risk models (RMs) to predict individual sPC risk for biopsy-naïve men and men after previous biopsy. We retrospectively analyzed clinical parameters of 1159 men who underwent mpMRI prior to MRI/transrectal ultrasound fusion biopsy between 2012 and 2015. Multivariate regression analyses were used to determine significant sPC predictors for RM development. The prediction performance was compared with ERSPC-RCs, RCs refitted on our cohort, Prostate Imaging Reporting and Data System (PI-RADS) v1.0, and ERSPC-RC plus PI-RADSv1.0 using receiver-operating characteristics (ROCs). Discrimination and calibration of the RM, as well as net decision and reduction curve analyses were evaluated based on resampling methods. PSA, prostate volume, digital-rectal examination, and PI-RADS were significant sPC predictors and included in the RMs together with age. The ROC area under the curve of the RM for biopsy-naïve men was comparable with ERSPC-RC3 plus PI-RADSv1.0 (0.83 vs 0.84) but larger compared with ERSPC-RC3 (0.81), refitted RC3 (0.80), and PI-RADS (0.76). For postbiopsy men, the novel RM's discrimination (0.81) was higher, compared with PI-RADS (0.78), ERSPC-RC4 (0.66), refitted RC4 (0.76), and ERSPC-RC4 plus PI-RADSv1.0 (0.78). Both RM benefits exceeded those of ERSPC-RCs and PI-RADS in the decision regarding which patient to receive biopsy and enabled the highest reduction rate of unnecessary biopsies. Limitations include a monocentric design and a lack of PI-RADSv2.0. The novel RMs, incorporating clinical parameters and PI-RADS, performed significantly better

  7. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

    PubMed Central

    Cirla, A.; Rondena, M.; Bertolini, G.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512

  8. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

    PubMed

    Cirla, A; Rondena, M; Bertolini, G

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.

  9. Use of a frameless computed tomography-guided stereotactic biopsy system for nasal biopsy in five dogs.

    PubMed

    Kuhlman, Gregory M; Taylor, Amanda R; Thieman-Mankin, Kelley M; Griffin, Jay; Cook, Audrey K; Levine, Jonathan M

    2016-04-15

    5 dogs (median age, 9 years; median body weight, 31 kg [68.2 lb]) with undefined nasal masses were examined after undergoing CT of the head and nasal biopsy via a rostral rhinoscopic or unaided (blind) approach because histologic results for collected biopsy specimens (inflammatory, necrotic, or hemorrhagic disease) suggested the specimens were nonrepresentative of the underlying disease process identified via CT (aggressive or malignant disease). Clinical signs at the time dogs were evaluated included open-mouth breathing, sneezing, or unilateral epistaxis. Histologic findings pertaining to the original biopsy specimens were suggestive of benign processes such as inflammation. In an attempt to obtain better representative specimens, a frameless CT-guided stereotactic biopsy system (CTSBS) was used to collect additional biopsy specimens from masses within the nasal and sinus passages of the dogs. The second set of biopsy specimens was histologically evaluated. Histologic evaluation of biopsy specimens collected via the CTSBS revealed results suggestive of malignant neoplasia (specifically, chondrosarcoma, hemangiopericytoma, or undifferentiated sarcoma) for 3 dogs, mild mixed-cell inflammation for 1 dog, and hamartoma for 1 dog. No complications were reported. These findings resulted in a change in treatment recommendations for 3 dogs and confirmed that no additional treatment was required for 1 dog (with hamartoma). For the remaining dog, in which CT findings and clinical history were strongly suggestive of neoplasia, the final diagnosis was rhinitis. Biopsy specimens were safely collected from masses within the nasal and sinus passages of dogs by use of a frameless CTSBS, allowing a definitive diagnosis that was unachievable with other biopsy approaches.

  10. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    PubMed

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  11. Post-therapy lesions in patients with non-Hodgkin's lymphoma characterized by 18F-FDG PET/CT-guided biopsy using automated robotic biopsy arm.

    PubMed

    Radhakrishnan, Renjith K; Mittal, Bhagwant R; Basher, Rajender K; Prakash, Gaurav; Malhotra, Pankaj; Kalra, Naveen; Das, Ashim

    2018-01-01

    The aim of this study was to analyse the positive predictive value (PPV) of post-therapy fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT performed for response or recurrence evaluation in patients with non-Hodgkin's lymphoma (NHL) and to appraise the diagnostic utility of F-FDG PET/CT-guided biopsy in this setting. A total of 17 patients with NHL showing F-FDG avid lesions in F-FDG PET/CT performed for response or recurrence assessment underwent F-FDG PET/CT-guided biopsy using automated robotic biopsy arm needle navigation technique. The objectives were analysed in reference to histopathology. In all, 15 of the 17 (88.5%) procedures yielded adequate representative tissue samples. Nine out of 15 lesions were positive for residual disease and the remaining revealed benign findings on histopathology. One patient with inconclusive biopsy underwent surgical resection and histopathology confirmed the presence of residual disease. PPV of theF-FDG PET/CT was observed to be 62.5% (10/16). F-FDG PET/CT for response evaluation in NHL possesses a low PPV and hence warrants histopathological correlation when F-FDG PET/CT findings influence management decision. Diagnostic yield of F-FDG PET/CT-guided biopsy is high and has the potential to reduce sampling errors.

  12. Focal therapy for localized unifocal and multifocal prostate cancer: A prospective development study using real time MR guided focused ultrasound

    NASA Astrophysics Data System (ADS)

    Napoli, A.; Caliolo, G.; Boni, F.; Anzidei, M.; Catalano, C.

    2017-03-01

    To assess safety and feasibility of non-invasive high intensity 3T MR guided focused ultrasound (MRgFUS) treatment of localized prostate cancer in an exploratory designed study. Men aged 45-80 years were eligible for this prospective study if they had low-risk localized prostate cancer (prostate specific antigen [PSA] ≤10 ng/mL, Gleason score ≤ 3 + 3), with no previous androgen deprivation or treatment for prostate cancer, and who could safely undergo multiparametric MRI (Discovery 750, GE; Gd-Bopta, Bracco) and have a spinal anesthetic. Patients underwent focal therapy using real time MR guided high intensity focused ultrasound (MRgFUS), delivered to all known cancer lesions, with a margin of normal tissue. Primary endpoints were adverse events (serious and otherwise) and urinary symptoms and erectile function assessed using patient questionnaires. 8 men were recruited between June 2011 and June 2012. After treatment, one man was admitted to hospital for acute urinary retention. Another patient had self-resolving, mild, intermittent dysuria (median duration 5.0 days). Urinary tract infection was not reported. Urinary debris occurred in 6 men (75%), with a median duration of 12 days. Median overall International Index of Erectile Function-15 (IIEF-15) scores were similar at baseline and at 6 to 12 months (p=0.060), as were median IIEF-15 scores for intercourse satisfaction (p=0.433), sexual desire (p=0.622), and overall satisfaction (p=0.256). There was an improvement in lower urinary tract symptoms, assessed by International Prostate Symptom Score (IPSS), between baseline and 6 to 12 months (p=0.026). All 8 men with no baseline urinary incontinence were leak-free and pad-free by 9 months. No histological evidence of cancer was identified in 7 of 8 men biopsied at 6 months (87,5%); overall, the entire population (8 patients) was free of clinically significant cancer and had no evidence of disease on multi-parametric MRI at 6 to 12 months. MR guided Focused

  13. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    NASA Astrophysics Data System (ADS)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  14. Magnetic resonance spectroscopic imaging for improved treatment planning of prostate cancer

    NASA Astrophysics Data System (ADS)

    Venugopal, Niranjan

    Prostate cancer is the most common malignancy afflicting Canadian men in 2011. Physicians use digital rectal exams (DRE), blood tests for prostate specific antigen (PSA) and transrectal ultrasound (TRUS)-guided biopsies for the initial diagnosis of prostate cancer. None of these tests detail the spatial extent of prostate cancer - information critical for using new therapies that can target cancerous prostate. With an MRI technique called proton magnetic resonance spectroscopic imaging (1H-MRSI), biochemical analysis of the entire prostate can be done without the need for biopsy, providing detailed information beyond the non-specific changes in hardness felt by an experienced urologist in a DRE, the presence of PSA in blood, or the "blind-guidance" of TRUS-guided biopsy. A hindrance to acquiring high quality 1H-MRSI data comes from signal originating from fatty tissue surrounding prostate that tends to mask or distort signal from within the prostate, thus reducing the overall clinical usefulness of 1H-MRSI data. This thesis has three major areas of focus: 1) The development of an optimized 1H-MRSI technique, called conformal voxel magnetic resonance spectroscopy (CV-MRS), to deal the with removal of unwanted lipid contaminating artifacts at short and long echo times. 2) An in vivo human study to test the CV-MRS technique, including healthy volunteers and cancer patients scheduled for radical prostatectomy or radiation therapy. 3) A study to determine the efficacy of using the 1H-MRSI data for optimized radiation treatment planning using modern delivery techniques like intensity modulated radiation treatment. Data collected from the study using the optimized CV-MRS method show significantly reduced lipid contamination resulting in high quality spectra throughout the prostate. Combining the CV-MRS technique with spectral-spatial excitation further reduced lipid contamination and opened up the possibility of detecting metabolites with short T2 relaxation times

  15. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  16. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy

    PubMed Central

    2013-01-01

    Background Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. Methodology It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. Results A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). Conclusion CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis. PMID:23402220

  17. Ultrasound-Guided Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  18. Combined ultrasound-guided cutting-needle biopsy and standard pleural biopsy for diagnosis of malignant pleural effusions.

    PubMed

    Wang, Jinlin; Zhou, Xinghua; Xie, Xiaohong; Tang, Qing; Shen, Panxiao; Zeng, Yunxiang

    2016-11-17

    The most efficient approach to diagnose malignant pleural effusions (MPEs) is still controversial and uncertain. This study aimed to evaluate the utility of a combined approach using ultrasound (US)-guided cutting-needle biopsy (CNB) and standard pleural biopsy (SPB) for diagnosing MPE. Pleural effusions were collected from 172 patients for biochemical and microbiological analyses. US-guided CNB and SPB were performed in the same operation sequentially to obtain specimens for histological analysis. US-guided CNB and SPB procedures provided adequate material for histological analysis in 90.7 and 93.0% of cases, respectively, while a combination of the 2 techniques was in 96.5% of cases. The sensitivity, specificity, positive-predictive value (PPV), negative-predictive value (NPV) and diagnostic accuracy of US-guided CNB versus SPB were: 51.2 vs 63.4%, 100 vs 100%, 100 vs 100%, 64.9 vs 72.2% and 74.4 vs 81.3%, respectively. When CNB was combined with SPB, the corresponding values were 88.6, 100, 100, 88.6 and 93.9%, respectively. Whereas sensitivity, NPV and diagnostic accuracy were not significantly different between CNB and SPB, the combination of CNB and SPB significantly improved the sensitivity, NPV and diagnostic accuracy versus each technique alone (p < 0.05). Significant pain (eight patients), moderate haemoptysis (two patients) and chest wall haematomas (two patients) were observed following CNB, while syncope (four patients) and a slight pneumothorax (four patients) were observed following SPB. Use of a combination of US-guided CNB and SPB afforded a high sensitivity to diagnose MPEs, it is a convenient and safe approach.

  19. The role of ultrasonography in the management of lung and pleural diseases.

    PubMed

    Rumende, C Martin

    2012-04-01

    Ultrasonographic examination in pulmonology provides a revolutionary advance because it is very helpful in the diagnosis and management of various pleural and peripheral pulmonary defects. Lung ultrasonography allows the clinicians to diagnose some pulmonary abnormalities more rapidly, including the diagnosis of pleural effusion. Ultrasound examination also provides great assistance for the clinicians to perform invasive techniques in the field of pulmonology, which may increase the success rate and reduce the likelihood of complications. In addition to pleural effusion, other lung disorders can be diagnosed by ultrasound such as peripheral lung tumors and other pleural abnormalities caused by pleural fibrosis and tumor metastasis as well as the primary pleural tumor (mesothelioma). Ultrasound-guided invasive procedures include aspiration of minimal effusion, Transthoracal Needle Aspiration, Transthoracal biopsies and chest tube insertion. Lung ultrasound also offers other advantages, i.e. free from radiation hazards, portable, non-invasive and relatively inexpensive. Ultrasonography in the thorax also has its limitations, especially in detecting mediastinal abnormalities.

  20. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    PubMed Central

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M.; Tempany, Clare M.; Cormack, Robert A.

    2012-01-01

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed