Sample records for ultrasound enhanced thrombolysis

  1. Effect of modulated ultrasound parameters on ultrasound-induced thrombolysis.

    PubMed

    Soltani, Azita; Volz, Kim R; Hansmann, Doulas R

    2008-12-07

    The potential of ultrasound to enhance enzyme-mediated thrombolysis by application of constant operating parameters (COP) has been widely demonstrated. In this study, the effect of ultrasound with modulated operating parameters (MOP) on enzyme-mediated thrombolysis was investigated. The MOP protocol was applied to an in vitro model of thrombolysis. The results were compared to a COP with the equivalent soft tissue thermal index (TIS) over the duration of ultrasound exposure of 30 min (p < 0.14). To explore potential differences in the mechanism responsible for ultrasound-induced thrombolysis, a perfusion model was used to measure changes in average fibrin pore size of clot before, after and during exposure to MOP and COP protocols and cavitational activity was monitored in real time for both protocols using a passive cavitation detection system. The relative lysis enhancement by each COP and MOP protocol compared to alteplase alone yielded values of 33.69 +/- 12.09% and 63.89 +/- 15.02% in a thrombolysis model, respectively (p < 0.007). Both COP and MOP protocols caused an equivalent significant increase in average clot pore size of 2.09 x 10(-2) +/- 0.01 microm and 1.99 x 10(-2) +/- 0.004 microm, respectively (p < 0.74). No signatures of inertial or stable cavitation were observed for either acoustic protocol. In conclusion, due to mechanisms other than cavitation, application of ultrasound with modulated operating parameters has the potential to significantly enhance the relative lysis enhancement compared to application of ultrasound with constant operating parameters.

  2. 76 FR 31616 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... DD. Ultrasound-facilitated thrombolysis using tissue-plasminogen activator-loaded echogenic liposomes... al. Pulsed-high intensity focused ultrasound enhances thrombolysis in an in vitro model. Radiology...

  3. Microbubble mediated dual-frequency high intensity focused ultrasound thrombolysis: An In vitro study

    NASA Astrophysics Data System (ADS)

    Suo, Dingjie; Jin, Zhiyang; Jiang, Xiaoning; Dayton, Paul A.; Jing, Yun

    2017-01-01

    High intensity focused ultrasound (HIFU) has recently emerged as a promising alternative approach for thrombolysis. However, the high acoustic energy required by HIFU could elicit thermal damage bioeffects, impeding the clinical translation of this technique. This paper investigates the use of dual-frequency focused ultrasound (DFFU) mediated by microbubbles (MBs) to minimize the acoustic power required for thrombolysis in vitro. It was found that MBs, with sufficient concentration, could significantly lower the power threshold for thrombolysis for both DFFU and single-frequency focused ultrasound (SFFU). In addition, SFFU needs about 96%-156% higher energy to achieve the same thrombolysis efficiency as that of DFFU. The thrombolysis efficiency is also found to increase with the duty cycle. The measured cavitation signals reveal that the enhanced inertial cavitation is likely responsible for the improved thrombolysis under DFFU and MBs.

  4. Clot retraction affects the extent of ultrasound-enhanced thrombolysis in an ex vivo porcine thrombosis model

    PubMed Central

    Sutton, Jonathan T.; Ivancevich, Nikolas M.; Perrin, Stephen R.; Vela, Deborah C.; Holland, Christy K.

    2013-01-01

    Using an FDA-approved contrast agent (Definity®) and thrombolytic drug (rt-PA), we investigated ultrasound-enhanced thrombolysis in two whole-blood clot models. Porcine venous blood was collected from donor hogs and coagulated in two different materials. This method produced clots with differing compositional properties, as determined by routine scanning electron microscopy and histology. Clots were deployed in an ex vivo porcine thrombolysis model, while an intermittent ultrasound scheme previously developed to maximize stable cavitation was applied and acoustic emissions were detected. Exposure of clots to 3.15 μg/mL rt-PA promoted lysis in both clot models, compared to exposure to plasma alone. However, in the presence of rt-PA, Definity®, and ultrasound, only unretracted clots experienced significant enhancement of thrombolysis compared to treatment with rt-PA. In these clots, microscopy studies revealed loose erythrocyte aggregates, a significantly less extensive fibrin network, and a higher porosity, which may facilitate increase penetration of thrombolytics by cavitation. PMID:23453629

  5. ULTRASOUND-ENHANCED rt-PA THROMBOLYSIS IN AN EX VIVO PORCINE CAROTID ARTERY MODEL

    PubMed Central

    Hitchcock, Kathryn E.; Ivancevich, Nikolas M.; Haworth, Kevin J.; Caudell Stamper, Danielle N.; Vela, Deborah C.; Sutton, Jonathan T.; Pyne-Geithman, Gail J.; Holland, Christy K.

    2014-01-01

    Ultrasound is known to enhance recombinant tissue plasminogen activator (rt-PA) thrombolysis. In this study, occlusive porcine whole blood clots were placed in flowing plasma within living porcine carotid arteries. Ultrasonically induced stable cavitation was investigated as an adjuvant to rt-PA thrombolysis. Aged, retracted clots were exposed to plasma alone, plasma containing rt-PA (7.1 ± 3.8 μg/mL) or plasma with rt-PA and Definity® ultrasound contrast agent (0.79 ± 0.47 μL/mL) with and without 120-kHz continuous wave ultrasound at a peak-to-peak pressure amplitude of 0.44 MPa. An insonation scheme was formulated to promote and maximize stable cavitation activity by incorporating ultrasound quiescent periods that allowed for the inflow of Definity®-rich plasma. Cavitation was measured with a passive acoustic detector throughout thrombolytic treatment. Thrombolytic efficacy was measured by comparing clot mass before and after treatment. Average mass loss for clots exposed to rt-PA and Definity® without ultrasound (n = 7) was 34%, and with ultrasound (n = 6) was 83%, which constituted a significant difference (p < 0.0001). Without Definity® there was no thrombolytic enhancement by ultrasound exposure alone at this pressure amplitude (n = 5, p < 0.0001). In the low-oxygen environment of the ischemic artery, significant loss of endothelium occurred but no correlation was observed between arterial tissue damage and treatment type. Acoustic stable cavitation nucleated by an infusion of Definity® enhances rt-PA thrombolysis without apparent treatment-related damage in this ex vivo porcine carotid artery model. PMID:21723448

  6. Ultrasound-enhanced rt-PA thrombolysis in an ex vivo porcine carotid artery model.

    PubMed

    Hitchcock, Kathryn E; Ivancevich, Nikolas M; Haworth, Kevin J; Caudell Stamper, Danielle N; Vela, Deborah C; Sutton, Jonathan T; Pyne-Geithman, Gail J; Holland, Christy K

    2011-08-01

    Ultrasound is known to enhance recombinant tissue plasminogen activator (rt-PA) thrombolysis. In this study, occlusive porcine whole blood clots were placed in flowing plasma within living porcine carotid arteries. Ultrasonically induced stable cavitation was investigated as an adjuvant to rt-PA thrombolysis. Aged, retracted clots were exposed to plasma alone, plasma containing rt-PA (7.1 ± 3.8 μg/mL) or plasma with rt-PA and Definity® ultrasound contrast agent (0.79 ± 0.47 μL/mL) with and without 120-kHz continuous wave ultrasound at a peak-to-peak pressure amplitude of 0.44 MPa. An insonation scheme was formulated to promote and maximize stable cavitation activity by incorporating ultrasound quiescent periods that allowed for the inflow of Definity®-rich plasma. Cavitation was measured with a passive acoustic detector throughout thrombolytic treatment. Thrombolytic efficacy was measured by comparing clot mass before and after treatment. Average mass loss for clots exposed to rt-PA and Definity® without ultrasound (n = 7) was 34%, and with ultrasound (n = 6) was 83%, which constituted a significant difference (p < 0.0001). Without Definity® there was no thrombolytic enhancement by ultrasound exposure alone at this pressure amplitude (n = 5, p < 0.0001). In the low-oxygen environment of the ischemic artery, significant loss of endothelium occurred but no correlation was observed between arterial tissue damage and treatment type. Acoustic stable cavitation nucleated by an infusion of Definity® enhances rt-PA thrombolysis without apparent treatment-related damage in this ex vivo porcine carotid artery model. Copyright © 2011. Published by Elsevier Inc.

  7. High Intensity Focused Ultrasound (HIFU) Based Thrombolysis Using Multiple Frequency Excitations

    NASA Astrophysics Data System (ADS)

    Suo, Dingjie

    High intensity focused ultrasound (HIFU) based thrombolysis has emerged as a promising drug-free approach for ischemic stroke treatment. The large amount of acoustic power required by this approach, however, poses a critical challenge to the future clinical translation because of the potential thermal damages. In this dissertation, multi-frequency acoustic waves at MHz range (near 1.5 MHz) were first introduced as HIFU excitations to reduce the required treatment power as well as the treatment time. It was found that dual-frequency thrombolysis efficiency was statistically better than that of single-frequency, under the same acoustic power and excitation condition. Microbubbles (MBs) combined with dual-frequency focused ultrasound (DFFU) for thrombolysis in vitro was then proposed to further reduce the power required. MBs are widely used in therapeutic ultrasound thrombolysis due to the nonlinear characteristics of their harmonic responses, coalescence and cavitation effects, which could further enhance efficiency. It was shown in this study that MBs, with sufficient concentration, could significantly lower the power threshold for thrombolysis for both DFFU and single-frequency focused ultrasound (SFFU). MBs mediated DFFU thrombolysis were then studied with a flow system that mimicked the blood flow in the artery of the brain. It was found that the cavitation threshold of a DFFU excitation yielded a lower level than that of a SFFU excitation. All the experimental results indicated that multi-frequency ultrasound could improve the thrombolysis efficiency. However, this was not well established numerically. Hence, a numerical investigation on the inertial cavitation threshold of MBs under multifrequency ultrasound irradiation was then investigated to confirm the benefit of using multi-frequency ultrasound for various applications. The main contribution and findings of this dissertation are as follows: 1) For the HIFU along study, when varying the acoustic power while fixing the duty cycle at 5%, it was found that almost 30% of the power can be saved by dual frequency ultrasound to achieve the same thrombolysis efficiency. In the experiment where the duty cycle was increased from 0.5% to 10%, it was shown that dual-frequency ultrasound can achieve the same thrombolysis efficiency with only half of the duty cycle of singlefrequency. Dual-frequency ultrasound could also accelerate the thrombolysis by a factor of 2-4 as demonstrated in this study. The measured cavitation doses of dual-frequency and triple-frequency excitations were at about the same level, both significantly higher than that of single-frequency. 2) For the MBs mediated thrombolysis study, SFFU needed about 96%-156% higher energy to achieve the same thrombolysis efficiency as that of DFFU. The thrombolysis efficiency was also found to increase with the duty cycle. The measured cavitation signals reveal that the enhanced inertial cavitation may contribute to the improved thrombolysis under DFFU and MBs. By adding the flow system, the inertial cavitation was higher than the static model. One reason could be the dissolution of MBs into the flow that lowered the concentration of MBs by a significant amount. In both cases, the inertial cavitation thresh holds of DFFU were lower than SFFU. 3) For the numerical study, we investigated the inertial cavitation threshold of MBs under multi-frequency ultrasound irradiation. The relationships between the cavitation threshold and MB size at various frequencies and in different media were investigated. The results for single, dual and triple frequency sonication showed that inertial cavitation thresholds can be reduced by introducing additional frequencies, which was consistent with previous experimental work. In addition, no significant difference was observed between dual frequency sonication with various frequency differences. This study also provided a possible route for optimizing ultrasound excitations for initiating inertial cavitation.

  8. Histotripsy Thrombolysis on Retracted Clots.

    PubMed

    Zhang, Xi; Owens, Gabe E; Cain, Charles A; Gurm, Hitinder S; Macoskey, Jonathan; Xu, Zhen

    2016-08-01

    Retracted blood clots have been previously recognized to be more resistant to drug-based thrombolysis methods, even with ultrasound and microbubble enhancements. Microtripsy, a new histotripsy approach, has been investigated as a non-invasive, drug-free and image-guided method that uses ultrasound to break up clots with improved treatment accuracy and a lower risk of vessel damage compared with the traditional histotripsy thrombolysis approach. Unlike drug-mediated thrombolysis, which is dependent on the permeation of the thrombolytic agents into the clot, microtripsy controls acoustic cavitation to fractionate clots. We hypothesize that microtripsy thrombolysis is effective on retracted clots and that the treatment efficacy can be enhanced using strategies incorporating electronic focal steering. To test our hypothesis, retracted clots were prepared in vitro and the mechanical properties were quantitatively characterized. Microtripsy thrombolysis was applied on the retracted clots in an in vitro flow model using three different strategies: single-focus, electronically-steered multi-focus and dual-pass multi-focus. Results show that microtripsy was used to successfully generate a flow channel through the retracted clot and the flow was restored. The multi-focus and the dual-pass treatments incorporating the electronic focal steering significantly increased the recanalized flow channel size compared to the single-focus treatments. The dual-pass treatments achieved a restored flow rate up to 324 mL/min without cavitation contacting the vessel wall. The clot debris particles generated from microtripsy thrombolysis remained within the safe range. The results of this study show the potential of microtripsy thrombolysis for retracted clot recanalization with the enhancement of electronic focal steering. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. A pragmatic approach to sonothrombolysis in acute ischaemic stroke: the Norwegian randomised controlled sonothrombolysis in acute stroke study (NOR-SASS).

    PubMed

    Nacu, Aliona; Kvistad, Christopher E; Logallo, Nicola; Naess, Halvor; Waje-Andreassen, Ulrike; Aamodt, Anne Hege; Solhoff, Ragnar; Lund, Christian; Tobro, Håkon; Rønning, Ole Morten; Salvesen, Rolf; Idicula, Titto T; Thomassen, Lars

    2015-07-11

    Ultrasound accelerates thrombolysis with tPA (sonothrombolysis). Ultrasound in the absence of tPA also accelerates clot break-up (sonolysis). Adding intravenous gaseous microbubbles may potentiate the effect of ultrasound in both sonothrombolysis and sonolysis. The Norwegian Sonothrombolysis in Acute Stroke Study aims in a pragmatic approach to assess the effect and safety of contrast enhanced ultrasound treatment in unselected acute ischaemic stroke patients. Acute ischaemic stroke patients ≥ 18 years, with or without visible arterial occlusion on computed tomography angiography (CTA) and treatable ≤ 4(½) hours after symptom onset, are included in NOR-SASS. NOR-SASS is superimposed on a separate trial randomising patients with acute ischemic stroke to either tenecteplase or alteplase (The Norwegian Tenecteplase Stroke Trial NOR-TEST). The NOR-SASS trial has two arms: 1) the thrombolysis-arms (NOR-SASS A and B) includes patients given intravenous thrombolysis (tenecteplase or alteplase), and 2) the no-thrombolysis-arm (NOR-SASS C) includes patients with contraindications to thrombolysis. First step randomisation of NOR-SASS A is embedded in NOR-TEST as a 1:1 randomisation to either tenecteplase or alteplase. Second step NOR-SASS randomisation is 1:1 to either contrast enhanced sonothrombolysis (CEST) or sham CEST. Randomisation in NOR-SASS B (routine alteplase group) is 1:1 to either CEST or sham CEST. Randomisation of NOR-SASS C is 1:1 to either contrast enhanced sonolysis (CES) or sham CES. Ultrasound is given for one hour using a 2-MHz pulsed-wave diagnostic ultrasound probe. Microbubble contrast (SonoVue®) is given as a continuous infusion for ~30 min. Recanalisation is assessed at 60 min after start of CEST/CES. Magnetic resonance imaging and angiography is performed after 24 h of stroke onset. Primary study endpoints are 1) major neurological improvement measured with NIHSS score at 24 h and 2) favourable functional outcome defined as mRS 0-1 at 90 days. NOR-SASS is the first randomised controlled trial designed to test the superiority of contrast enhanced ultrasound treatment given ≤ 4(½) hours after stroke onset in an unselected acute ischaemic stroke population eligible or not eligible for intravenous thrombolysis, with or without a defined arterial occlusion on CTA. If a positive effect and safety can be proven, contrast enhanced ultrasound treatment will be an option for all acute ischaemic stroke patients. EudraCT No 201200032341; www.clinicaltrials.gov NCT01949961.

  10. Clot retraction affects the extent of ultrasound-enhanced thrombolysis in an ex vivo porcine thrombosis model.

    PubMed

    Sutton, Jonathan T; Ivancevich, Nikolas M; Perrin, Stephen R; Vela, Deborah C; Holland, Christy K

    2013-05-01

    We investigated ultrasound-enhanced thrombolysis in two whole-blood clot models using a Food and Drug Administration-approved contrast agent (Definity, Lantheus Medical Imaging; Billerica, MA USA) and thrombolytic drug (recombinant tissue-type plasminogen activator [rt-PA]) (Genentech; South San Francisco, CA USA). Porcine venous blood was collected from donor hogs and coagulated in vials made of two different materials. This method produced clots with differing compositional properties, as determined by routine scanning electron microscopy and histology. Clots were deployed in an ex vivo porcine thrombosis model, and exposed to an intermittent ultrasound scheme previously developed to maximize stable cavitation while acoustic emissions were detected. Exposure to 3.15 μg/mL rt-PA promoted lysis in both clot models, compared with exposure to plasma alone. However, only unretracted clots experienced significant enhancement of thrombolysis in the presence of rt-PA, Definity, and ultrasound, compared with treatment with rt-PA. In these clots, microscopy revealed loose erythrocyte aggregates, a significantly less extensive fibrin network and a higher porosity, which may facilitate increased penetration of thrombolytics by cavitation. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Histotripsy Thrombolysis on Retracted Clots

    PubMed Central

    Zhang, Xi; Owens, Gabe E.; Cain, Charles A.; Gurm, Hitinder S.; Macoskey, Jonathan; Xu, Zhen

    2016-01-01

    Retracted blood clots have been previously recognized to be more resistant to drug-based thrombolysis methods, even with ultrasound and microbubble enhancements. Microtripsy, a new histotripsy approach, has been investigated as a non-invasive, drug-free, and image-guided method that uses ultrasound to break up clots with improved treatment accuracy and a lower risk of vessel damage when compared to the traditional histotripsy thrombolysis approach. Unlike drug-mediated thrombolysis, which is dependent on the permeation of the thrombolytic agents into the clot, microtripsy controls acoustic cavitation to fractionate clots. We hypothesize that microtripsy thrombolysis is effective on retracted clots and that the treatment efficacy can be enhanced using strategies incorporating electronic focal steering. To test our hypothesis, retracted clots were prepared in vitro and the mechanical properties were quantitatively characterized. Microtripsy thrombolysis was applied on the retracted clots in an in vitro flow model using three different strategies: single-focus, electronically-steered multi-focus, and a dual-pass multi-focus strategy. Results show that microtripsy was used to successfully generate a flow channel through the retracted clot and the flow was restored. The multi-focus and the dual-pass treatments incorporating the electronic focal steering significantly increased the recanalized flow channel size compared to the single-focus treatments. The dual-pass treatments achieved a restored flow rate up to 324 mL/min without cavitation contacting the vessel wall. The clot debris particles generated from microtripsy thrombolysis remained within the safe range. The results in this study show the potential of microtripsy thrombolysis for retracted clot recanalization with the enhancement of electronic focal steering. PMID:27166017

  12. Sonothrombolysis

    PubMed Central

    Bader, Kenneth B.; Bouchoux, Guillaume

    2016-01-01

    Thrombo-occlusive disease is a leading cause of morbidity and mortality. In this chapter, the use of ultrasound to accelerate clot breakdown alone or in combination with thrombolytic drugs will be reported. Primary thrombus formation during cardiovascular disease and standard treatment methods will be discussed. Mechanisms for ultrasound enhancement of thrombolysis, including thermal heating, radiation force, and cavitation, will be reviewed. Finally, in-vitro, in-vivo and clinical evidence of enhanced thrombolytic efficacy with ultrasound will be presented and discussed. PMID:26486347

  13. Ultrasound-enhanced thrombolysis using Definity as a cavitation nucleation agent.

    PubMed

    Datta, Saurabh; Coussios, Constantin-C; Ammi, Azzdine Y; Mast, T Douglas; de Courten-Myers, Gabrielle M; Holland, Christy K

    2008-09-01

    Ultrasound has been shown previously to act synergistically with a thrombolytic agent, such as recombinant tissue plasminogen activator (rt-PA) to accelerate thrombolysis. In this in vitro study, a commercial contrast agent, Definity, was used to promote and sustain the nucleation of cavitation during pulsed ultrasound exposure at 120 kHz. Ultraharmonic signals, broadband emissions and harmonics of the fundamental were measured acoustically by using a focused hydrophone as a passive cavitation detector and used to quantify the level of cavitation activity. Human whole blood clots suspended in human plasma were exposed to a combination of rt-PA, Definity and ultrasound at a range of ultrasound peak-to-peak pressure amplitudes, which were selected to expose clots to various degrees of cavitation activity. Thrombolytic efficacy was determined by measuring clot mass loss before and after the treatment and correlated with the degree of cavitation activity. The penetration depth of rt-PA and plasminogen was also evaluated in the presence of cavitating microbubbles using a dual-antibody fluorescence imaging technique. The largest mass loss (26.2%) was observed for clots treated with 120-kHz ultrasound (0.32-MPa peak-to-peak pressure amplitude), rt-PA and stable cavitation nucleated by Definity. A significant correlation was observed between mass loss and ultraharmonic signals (r = 0.85, p < 0.0001, n = 24). The largest mean penetration depth of rt-PA (222 microm) and plasminogen (241 microm) was observed in the presence of stable cavitation activity. Stable cavitation activity plays an important role in enhancement of thrombolysis and can be monitored to evaluate the efficacy of thrombolytic treatment.

  14. Effects of ultrasound-induced inertial cavitation on enzymatic thrombolysis.

    PubMed

    Chuang, Yueh-Hsun; Cheng, Po-Wen; Chen, Szu-Chia; Ruan, Jia-Ling; Li, Pai-Chi

    2010-04-01

    Cavitation induced by ultrasound enhances enzymatic fibrinolysis by increasing the transport of reactants. However, the effects of cavitation need to be fully understood before sonothrombolysis can be applied clinically. In order to understand the underlying mechanisms, we examined the effects of combining ultrasound, microbubbles and thrombolytic enzymes on thrombolysis. First, we evaluated the relations between inertial cavitation and the reduction in the weight of a blood clot. Inertial cavitation was varied by changing the amplitude and duration of the transmitted acoustic wave as well as the concentration of microbubbles used to induce cavitation. Second, we studied the combined effects of streptokinase and inertial cavitation on thrombolysis. The results show that inertial cavitation increases the weight reduction of a blood clot by up to 33.9%. With linear regression fitting, the measured differential inertial cavitation dose and the weight reduction had a correlation coefficient of 0.66. Microscopically, enzymatic thrombolysis effects manifest as multiple large cavities within the clot that are uniformly distributed on the side exposed to ultrasound. This suggests that inertial cavitation plays an important role in producing cavities, while microjetting of the microbubbles induces pits on the clot surface. These observations preliminarily demonstrate the clinical potential of sonothrombolysis. The use of the differential inertial cavitation dose as an indicator of blood clot weight loss for controlled sonothrombolysis is also possible and will be further explored.

  15. Cavitation thresholds of contrast agents in an in vitro human clot model exposed to 120-kHz ultrasound.

    PubMed

    Gruber, Matthew J; Bader, Kenneth B; Holland, Christy K

    2014-02-01

    Ultrasound contrast agents (UCAs) can be employed to nucleate cavitation to achieve desired bioeffects, such as thrombolysis, in therapeutic ultrasound applications. Effective methods of enhancing thrombolysis with ultrasound have been examined at low frequencies (<1 MHz) and low amplitudes (<0.5 MPa). The objective of this study was to determine cavitation thresholds for two UCAs exposed to 120-kHz ultrasound. A commercial ultrasound contrast agent (Definity(®)) and echogenic liposomes were investigated to determine the acoustic pressure threshold for ultraharmonic (UH) and broadband (BB) generation using an in vitro flow model perfused with human plasma. Cavitation emissions were detected using two passive receivers over a narrow frequency bandwidth (540-900 kHz) and a broad frequency bandwidth (0.54-1.74 MHz). UH and BB cavitation thresholds occurred at the same acoustic pressure (0.3 ± 0.1 MPa, peak to peak) and were found to depend on the sensitivity of the cavitation detector but not on the nucleating contrast agent or ultrasound duty cycle.

  16. Intravascular forward-looking ultrasound transducers for microbubble-mediated sonothrombolysis.

    PubMed

    Kim, Jinwook; Lindsey, Brooks D; Chang, Wei-Yi; Dai, Xuming; Stavas, Joseph M; Dayton, Paul A; Jiang, Xiaoning

    2017-06-14

    Effective removal or dissolution of large blood clots remains a challenge in clinical treatment of acute thrombo-occlusive diseases. Here we report the development of an intravascular microbubble-mediated sonothrombolysis device for improving thrombolytic rate and thus minimizing the required dose of thrombolytic drugs. We hypothesize that a sub-megahertz, forward-looking ultrasound transducer with an integrated microbubble injection tube is more advantageous for efficient thrombolysis by enhancing cavitation-induced microstreaming than the conventional high-frequency, side-looking, catheter-mounted transducers. We developed custom miniaturized transducers and demonstrated that these transducers are able to generate sufficient pressure to induce cavitation of lipid-shelled microbubble contrast agents. Our technology demonstrates a thrombolysis rate of 0.7 ± 0.15 percent mass loss/min in vitro without any use of thrombolytic drugs.

  17. Non-Invasive Thrombolysis Using Pulsed Ultrasound Cavitation Therapy – Histotripsy

    PubMed Central

    Maxwell, Adam D.; Cain, Charles A.; Duryea, Alexander P.; Yuan, Lingqian; Gurm, Hitinder S.; Xu, Zhen

    2009-01-01

    Clinically available thrombolysis techniques are limited by either slow reperfusion (drugs) or invasiveness (catheters), and carry significant risks of bleeding. In this study, the feasibility of using histotripsy as an efficient and non-invasive thrombolysis technique was investigated. Histotripsy fractionates soft tissue through controlled cavitation using focused, short, high-intensity ultrasound pulses. In-vitro blood clots formed from fresh canine blood were treated by histotripsy. The treatment was applied using a focused 1-MHz transducer, with 5-cycle pulses at a pulse repetition rate of 1 kHz. Acoustic pressures varying from 2 – 12 MPa peak negative pressure were tested. Our results show that histotripsy can perform effective thrombolysis with ultrasound energy alone. Histotripsy thrombolysis only occurred at peak negative pressure ≥6 MPa when initiation of a cavitating bubble cloud was detected using acoustic backscatter monitoring. Blood clots weighing 330 mg were completely broken down by histotripsy in 1.5 – 5 minutes. The clot was fractionated to debris with >96% weight smaller than 5 μm diameter. Histotripsy thrombolysis treatment remained effective under a fast, pulsating flow (a circulatory model) as well as in static saline. Additionally, we observed that fluid flow generated by a cavitation cloud can attract, trap, and further break down clot fragments. This phenomenon may provide a non-invasive method to filter and eliminate hazardous emboli during thrombolysis. PMID:19854563

  18. Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: an in vitro study

    NASA Astrophysics Data System (ADS)

    Suo, Dingjie; Guo, Sijia; Lin, Weili; Jiang, Xiaoning; Jing, Yun

    2015-09-01

    High intensity focused ultrasound (HIFU) based thrombolysis has emerged as a promising drug-free treatment approach for ischemic stroke. The large amount of acoustic power required by this approach, however, poses a critical challenge to the future clinical translation. In this study, multi-frequency acoustic waves at MHz range (near 1.5 MHz) were introduced as HIFU excitations to reduce the required power for treatment as well as the treatment time. In vitro bovine blood clots weighing around 150 mg were treated by single-frequency and multi-frequency HIFU. The pulse length was 2 ms for all experiments except the ones where the duty cycle was changed. It was found that dual-frequency thrombolysis efficiency was statistically better than single-frequency under the same acoustic power and excitation condition. When varying the acoustic power but fixing the duty cycle at 5%, it was found that dual-frequency ultrasound can save almost 30% power in order to achieve the same thrombolysis efficiency. In the experiment where the duty cycle was increased from 0.5% to 10%, it was shown that dual-frequency ultrasound can achieve the same thrombolysis efficiency with only half of the duty cycle of single-frequency. Dual-frequency ultrasound could also accelerate the thrombolysis by a factor of 2-4 as demonstrated in this study. No significant differences were found between dual-frequencies with different frequency differences (0.025, 0.05, and 0.1 MHz) and between dual-frequency and triple-frequency. The measured cavitation doses of dual-frequency and triple-frequency excitations were at about the same level but both were significantly higher than that of single-frequency.

  19. Investigations on the destruction of ultrasound contrast agents: Fragmentation thresholds, inertial cavitation, and bioeffects

    NASA Astrophysics Data System (ADS)

    Chen, Wen-Shiang

    Ultrasound contrast agents (UCA) have shown great potential in both diagnostic and therapeutic applications recently. To fully explore the possible applications and the safety concerns of using UCA, a complete understanding of the UCA responses to various acoustic fields is necessary. Therefore, we performed a series of experiments and simulations to investigate the various acoustic properties of UCA with different gases and shells. We also investigated the mechanisms of some UCA-enhanced bioeffects including thrombolysis, hemolysis and high-intensity focused ultrasound (HIFU) tumor ablation. Two pressure thresholds were found: the fragmentation threshold and continuous inertial cavitation (IC) threshold. At the fragmentation threshold, bubbles were destroyed and the released gas dissolved in the surrounding solution at a rate which depended on the bubble's initial size and type of gas. The continuous IC threshold occurred at a higher pressure, where fragments of destroyed UCA (derivative bubbles) underwent violent inertial collapse; the period of activity depending on acoustic parameters such as frequency, pressure, pulse length, and pulse repetition frequency (PRF). Different UCA had different threshold pressures and demonstrated different magnitudes of IC activity after destruction. The amount of derivative bubbles generated by IC was determined by several acoustic parameters including pressure, pulse length and PRE For the same acoustic energy delivered, longer pulses generated more bubbles. More IC could be induced if the derivative bubbles could survive through the 'off' period of the pulsed ultrasound waves, and served as nuclei for the subsequent IC. In therapeutic applications, evidences of IC activity were recorded during the hemolysis, thrombolysis, and the lesion-formation processes with UCA. Hemolysis and thrombolysis were highly correlated to the presence of ultrasound and UCA, and correlated well with the amount of the IC activity. Finally, the 'tadpole-shaped' lesion formed during high-intensity, focused ultrasound treatment was the result of bubble formation by boiling.

  20. Stable cavitation using acoustic phase-change dodecafluoropentane nanoparticles for coronary micro-circulation thrombolysis.

    PubMed

    Hu, Bo; Jiang, Nan; Zhou, Qing; Cao, Sheng; Gao, Shunji; Zhang, Binghong; Chen, Jinling; Guo, Ruiqiang

    2018-06-11

    The thrombolysis in micro-circulation after acute myocardial infarction has been an unsolved issue, as elimination effect of acute thrombolysis and primary intervention were unsatisfied. Stable cavitation using acoustic phase-change nanoparticles may have potential for thrombolysis. Therefore, we sought to investigate a novel treatment method with dodecafluoropentane (DDFP) nanoparticles for rapid and effective thrombolysis in an in-vitro artificial vascular system, as a mimicking preparation of coronary circulation. To simulate thrombus embolism in coronary circulation, an in-vitro artificial vascular system was established with cavitation effect using DDFP nanoparticles. For PBS blank control (group A), SonoVue microbubbles (group B) and DDFP nanoparticles (group C), the durations for cavitation effect were recorded and the thrombolysis efficiency with low intensity focused ultrasound irradiation in the in-vitro vascular system were analyzed with weight loss and pathological changes of thrombus before and after thrombolysis. The optimal conditions for acoustic cavitation effect were power of 6 W for 20 min by ultrasound irradiation at 37 °C. The weight loss and weight loss rates of thrombus in group C (189.4 ± 30.2 mg and 34.2 ± 5.7%) were higher than those in group A (30.2 ± 16.0 mg and 5.2 ± 2.1%) and group B (84.0 ± 20.4 mg and 14.6 ± 1.5%) (P < 0.01, all). The duration for cavitation effect in group C (32.8 ± 3.9 min) was also longer than those in group A (0.0 ± 0.0 min) and group B (5.3 ± 0.3 min) (P < 0.01, all). By stable and sustaining cavitation in targeted area, DDFP nanoparticles with ultrasound irradiation have significantly increased the thrombolysis efficiency, which has provided a powerful experimental foundation for potential coronary thrombolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A Retrospective Comparison of Ultrasound-Assisted Catheter-Directed Thrombolysis and Catheter-Directed Thrombolysis Alone for Treatment of Proximal Deep Vein Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tichelaar, Vladimir Y. I. G., E-mail: ynse.i.tichelaar@uit.no; Brodin, Ellen E.; Vik, Anders

    BackgroundRecent studies have suggested that catheter-directed thrombolysis (CDT) reduces development of post-thrombotic syndrome (PTS). Ultrasound-assisted CDT (USCDT) might enhance the efficiency of thrombolysis. We aimed to compare USCDT with CDT on efficacy, safety, development of PTS, and quality of life after long-term follow-up.MethodsWe describe a retrospective case series of 94 consecutive patients admitted with iliofemoral or more proximal deep vein thrombosis (DVT) to the University Hospital from 2002 to 2011, treated either with CDT or USCDT. Scheduled follow-up visits took place between April 2013 and January 2014. Venography measured the degree of residual luminal obstruction of the affected veins. Eachmore » patient completed the Short Form 36-item health survey assessment and the Venous Insufficiency Epidemiological and Economic Study-Quality of Life/Symptoms questionnaires. PTS was assessed using the Villalta scale.ResultsRisk factors of DVT were equally distributed between groups. In the USCDT group, we observed a significant decline in the duration of thrombolytic treatment (<48 h: 27 vs. 10 %), shortened hospital stay (median 6.0 days (IQR 5.0–9.0) vs. 8.0 (IQR 5.8–12.0)), and less implantation of (intravenous) stents (30 vs. 55 %). There was no difference in patency (76 vs. 79 % fully patent), prevalence of PTS (52 vs. 55 %), or quality of life between groups after long-term follow-up (median 65 months, range: 15–141).ConclusionsIn this observational study, USCDT was associated with shortened treatment duration, shorter hospital stay, and less intravenous stenting, compared to CDT alone without affecting the long-term prevalence of PTS or quality of life.« less

  2. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    PubMed

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  3. Effect of clot aging and cholesterol content on ultrasound-assisted thrombolysis.

    PubMed

    Zhou, Yufeng; Murugappan, Suresh Kanna; Sharma, Vijay Kumar

    2014-10-01

    Exposure to 2-MHz transcranial diagnostic ultrasound enhances the thrombolytic activity of intravenously administered tissue plasminogen activator (IV-tPA) in acute ischemic stroke (sonothrombolysis). However, rates of arterial recanalization vary widely, depending upon the clot burden, its location, and stroke subtype. We evaluated the influence of age and cholesterol level of the blood clots on sonothrombolysis in an in vitro model. To "age" the clots, serum was replaced by fresh blood periodically. We increased the cholesterol content of the clots by adding cholesterin to the blood. The clots were lysed by tPA and/or transcranial Doppler ultrasound sonication for 1 h. The extent of thrombolysis induced by various treatment protocols (controls, sonication, tPA, and sonothrombolysis) was evaluated with relative changes in the clot weights and in the clot structure by scanning electron microscopy (SEM) at end of the experiment. Sonothrombolysis induced significantly higher weight reduction in fresh clots (37.3 % in 2-h old clots versus 24.8 % in 10-h ones, p < 0.005) as well as the clots with higher cholesterol levels (41.7 versus 30.6 % in normal cholesterol clots, p < 0.005). SEM demonstrated patterns of clot dissolution among various treatment modalities. Sonothrombolysis induced better clot lysis in fresh thrombi with high cholesterol levels.

  4. Effects of varying duty cycle and pulse width on high-intensity focused ultrasound (HIFU)-induced transcranial thrombolysis.

    PubMed

    Hölscher, Thilo; Raman, Rema; Fisher, David J; Ahadi, Golnaz; Zadicario, Eyal; Voie, Arne

    2013-01-01

    The goal was to test the effects of various combinations of pulse widths (PW) and duty cycles (DC) on high-intensity focused ultrasound (HIFU)-induced sonothrombolysis efficacy using an in vitro flow model. An ExAblate™ 4000 HIFU headsystem (InSightec, Inc., Israel) was used. Artificial blood clots were placed into test tubes inside a human calvarium and exposed to pulsatile flow. Four different duty cycles were tested against four different pulse widths. For all study groups, an increase in thrombolysis efficacy could be seen in association with increasing DC and/or PW (p < 0.0001). Using transcranial HIFU, significant thrombolysis can be achieved within seconds and without the use of lytic drugs in vitro. Longer duty cycles in combination with longer pulse widths seem to have the highest potential to optimize clot lysis efficacy.

  5. Effects of varying duty cycle and pulse width on high-intensity focused ultrasound (HIFU)-induced transcranial thrombolysis

    PubMed Central

    2013-01-01

    The goal was to test the effects of various combinations of pulse widths (PW) and duty cycles (DC) on high-intensity focused ultrasound (HIFU)-induced sonothrombolysis efficacy using an in vitro flow model. An ExAblate™ 4000 HIFU headsystem (InSightec, Inc., Israel) was used. Artificial blood clots were placed into test tubes inside a human calvarium and exposed to pulsatile flow. Four different duty cycles were tested against four different pulse widths. For all study groups, an increase in thrombolysis efficacy could be seen in association with increasing DC and/or PW (p < 0.0001). Using transcranial HIFU, significant thrombolysis can be achieved within seconds and without the use of lytic drugs in vitro. Longer duty cycles in combination with longer pulse widths seem to have the highest potential to optimize clot lysis efficacy. PMID:25512862

  6. Effect of low frequency ultrasound on combined rt-PA and eptifibatide thrombolysis in human clots.

    PubMed

    Meunier, Jason M; Holland, Christy K; Pancioli, Arthur M; Lindsell, Christopher J; Shaw, George J

    2009-01-01

    Fibrinolytics such as recombinant tissue plasminogen activator (rt-PA) are used to treat thrombotic disease such as acute myocardial infarction (AMI) and ischemic stroke. Interest in increasing efficacy and reducing side effects has led to the study of adjuncts such as GP IIb-IIIa inhibitors and ultrasound (US) enhanced thrombolysis. Currently, GP IIb-IIIa inhibitor and fibrinolytic treatment are often used in AMI, and are under investigation for stroke treatment. However, little is known of the efficacy of combined GP IIb-IIIa inhibitor, fibrinolytic and ultrasound treatment. We measure the lytic efficacy of rt-PA, eptifibatide (Epf) and 120 kHz ultrasound treatment in an in-vitro human clot model. Blood was drawn from 15 subjects after IRB approval. Clots were made in 20 microL pipettes, and placed in a water tank for microscopic visualization during lytic treatment. Clots were exposed to control, rt-PA (rt-PA), eptifibatide (Epf), or rt-PA+eptifibatide (rt-PA + Epf), with (+US) or without (-US) ultrasound for 30 minutes at 37 degrees C in human plasma. Clot lysis was measured over time, using a microscopic imaging technique. The fractional clot loss (FCL) and initial lytic rate (LR) were used to quantify lytic efficacy. LR values for (- US) treated clots were 0.8+/-0.1(control), 1.8+/-0.3 (Epf), 1.5+/-0.2 (rt-PA), and 1.3+/-0.4 (rt-PA + Epf) (% clot width/minute) respectively. In comparison, the (+ US) group exhibited LR values of 1.6+/-0.2 (control), 4.3+/-0.4 (Epf), 6.3+/-0.4 (rt-PA), and 4.6+/-0.6 (rt-PA + Epf). For (- US) treated clots, FCL was 6.0+/-0.8 (control), 9.2+/-2.5 (Epf), 15.6+/-1.7 (rt-PA), and 28.0+/-2.2% (rt-PA + Epf) respectively. FCL for (+ US) clots was 13.5+/-2.4 (control), 20.7+/-6.4 (Epf), 44.4+/-3.6 (rt-PA) and 30.3+/-3.6% (rt-PA + Epf) respectively. Although the addition of eptifibatide enhances the in-vitro lytic efficacy of rt-PA in the absence of ultrasound, the efficacy of ultrasound and rt-PA is greater than that of combined ultrasound, rt-PA and eptifibatide exposure.

  7. Effect of Low Frequency Ultrasound on Combined rt-PA and Eptifibatide Thrombolysis in Human Clots

    PubMed Central

    Meunier, Jason M.; Holland, Christy K.; Pancioli, Arthur M.; Lindsell, Christopher J.; Shaw, George J.

    2009-01-01

    Introduction Fibrinolytics such as recombinant tissue plasminogen activator (rt-PA) are used to treat thrombotic disease such as acute myocardial infarction (AMI) and ischemic stroke. Interest in increasing efficacy and reducing side effects has led to the study of adjuncts such as GP IIb-IIIa inhibitors and ultrasound (US) enhanced thrombolysis. Currently, GP IIb-IIIa inhibitor and fibrinolytic treatment are often used in AMI, and are under investigation for stroke treatment. However, little is known of the efficacy of combined GP IIb-IIIa inhibitor, fibrinolytic and ultrasound treatment. We measure the lytic efficacy of rt-PA, eptifibatide (Epf) and 120 kHz ultrasound treatment in an in-vitro human clot model. Materials and Methods Blood was drawn from 15 subjects after IRB approval. Clots were made in 20 μL pipettes, and placed in a water tank for microscopic visualization during lytic treatment. Clots were exposed to control, rt-PA (rt-PA), eptifibatide (Epf), or rt-PA+eptifibatide (rt-PA+Epf), with or without ultrasound for 30 minutes at 37°C in human plasma. Clot lysis was measured over time, using a microscopic imaging technique. The fractional clot loss (FCL) and initial lytic rate (LR) were used to quantify lytic efficacy. Results and Conclusions LR values for (−US) treated clots were 0.8±0.1(control), 1.8±0.3 (Epf), 1.5±0.2 (rt-PA), and 1.3±0.4 (rt-PA+Epf) (% clot width/minute) respectively. In comparison, the (+US) group exhibited LR values of 1.6±0.2 (control), 4.3±0.4 (Epf), 6.3±0.4 (rt-PA), and 4.6±0.6 (rt-PA+Epf). For (−US) treated clots, FCL was 6.0±0.8 (control), 9.2±2.5 (Epf), 15.6±1.7 (rt-PA), and 28.0±2.2% (rt-PA+Epf) respectively. FCL for (+US) clots was 13.5±2.4 (control), 20.7±6.4 (Epf), 44.4±3.6 (rt-PA) and 30.3±3.6% (rt-PA+Epf) respectively. Although the addition of eptifibatide enhances the in-vitro lytic efficacy of rt-PA in the absence of ultrasound, the efficacy of ultrasound and rt-PA is greater than that of combined ultrasound, rt-PA and eptifibatide exposure. PMID:18619651

  8. Numerical investigation of the inertial cavitation threshold under multi-frequency ultrasound.

    PubMed

    Suo, Dingjie; Govind, Bala; Zhang, Shengqi; Jing, Yun

    2018-03-01

    Through the introduction of multi-frequency sonication in High Intensity Focused Ultrasound (HIFU), enhancement of efficiency has been noted in several applications including thrombolysis, tissue ablation, sonochemistry, and sonoluminescence. One key experimental observation is that multi-frequency ultrasound can help lower the inertial cavitation threshold, thereby improving the power efficiency. However, this has not been well corroborated by the theory. In this paper, a numerical investigation on the inertial cavitation threshold of microbubbles (MBs) under multi-frequency ultrasound irradiation is conducted. The relationships between the cavitation threshold and MB size at various frequencies and in different media are investigated. The results of single-, dual and triple frequency sonication show reduced inertial cavitation thresholds by introducing additional frequencies which is consistent with previous experimental work. In addition, no significant difference is observed between dual frequency sonication with various frequency differences. This study, not only reaffirms the benefit of using multi-frequency ultrasound for various applications, but also provides a possible route for optimizing ultrasound excitations for initiating inertial cavitation. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. In vitro thrombolytic efficacy of echogenic liposomes loaded with tissue plasminogen activator and octafluoropropane gas

    NASA Astrophysics Data System (ADS)

    Shekhar, Himanshu; Bader, Kenneth B.; Huang, Shenwen; Peng, Tao; Huang, Shaoling; McPherson, David D.; Holland, Christy K.

    2017-01-01

    Echogenic liposomes loaded with the thrombolytic recombinant tissue-type plasminogen activator (rt-PA) are under development for the treatment of ischemic stroke. These agents are designed to co-encapsulate cavitation nuclei to promote bubble activity in response to ultrasound exposure, and to enable localized delivery of thrombolytic. Stable cavitation improves the efficacy of the thrombolytic through enhanced fluid mixing. Echogenic liposomes that encapsulate air-filled microbubbles nucleate scant stable cavitation activity in response to 120 kHz intermittent ultrasound exposure, and have demonstrated thrombolytic efficacy equivalent to rt-PA alone. It was hypothesized that encapsulating octafluoropropane (OFP) gas within rt-PA-loaded liposomes instead of air will enhance ultrasound-mediated stable cavitation activity and increase thrombolytic efficacy compared to previous studies. The thrombolytic efficacy and cavitation activity nucleated from liposomes that encapsulate OFP microbubbles and rt-PA (OFP t-ELIP) was evaluated in vitro. Human whole blood clots were exposed to human fresh-frozen plasma alone, rt-PA (0, 0.32, 1.58, and 3.15 µg ml-1), or OFP t-ELIP at equivalent enzymatic activity, with and without exposure to intermittent ultrasound. Further, numerical simulations were performed to gain insight into the mechanisms of cavitation nucleation. Sustained ultraharmonic activity was nucleated from OFP t-ELIP when exposed to ultrasound. Furthermore, the thrombolytic efficacy was enhanced compared to rt-PA alone at concentrations of 1.58 µg ml-1 and 3.15 µg ml-1 (p  <  0.05). These results indicate that OFP t-ELIP can nucleate sustained stable cavitation activity and enhance the efficacy of thrombolysis.

  10. Ultrasound-Accelerated, Catheter-Directed Thrombolysis for Inferior Vena Cava Thrombosis After an Orthotopic Liver Transplant

    PubMed Central

    Latchana, Nicholas; Dowell, Joshua D.; Taani, Jamal Al; Michaels, Anthony; Elkhammas, Elmadhi; Black, Sylvester M.

    2015-01-01

    Inferior vena cava thrombosis is a rare occurrence after an orthotopic liver transplant that is associated with a high rate of retransplant and mortality. There is no consensus regarding the optimal therapeutic strategy. Surgical management, including thrombectomy with revision of the cavocaval anastomosis, has been described. With the use of endovascular therapies, several minimally invasive approaches are available that are effective and avoid the high morbidity associated with reoperative surgery. We describe our successful experience using an approach after a liver transplant in which the inferior vena cava thrombosis in a patient presenting with acute renal failure, anorexia, weight loss, and fatigue using an ultrasound-accelerated, catheter-directed thrombolysis platform in conjunction with systemic anticoagulation. PMID:24918871

  11. Acousto-mechanical and thermal properties of clotted blooda)

    PubMed Central

    Nahirnyak, Volodymyr M.; Yoon, Suk Wang; Holland, Christy K.

    2007-01-01

    The efficacy of ultrasound-assisted thrombolysis as an adjunct treatment of ischemic stroke is being widely investigated. To determine the role of ultrasound hyperthermia in the process of blood clot disruption, the acousto-mechanical and thermal properties of clotted blood were measured in vitro, namely, density, speed of sound, frequency-dependent attenuation, specific heat, and thermal conductivity. The amplitude coefficient of attenuation of the clots was determined for 120 kHz, 1.0 MHz, and 3.5 MHz ultrasound at room temperature (20±2 °C). The attenuation coefficient ranged from 0.10 to 0.30 Np/cm in porcine clots and from 0.09 to 0.23 Np/cm in human clots. The experimentally determined values of specific heat and thermal conductivity for porcine clotted blood are (3.2±0.5)×103 J/kg·K and 0.55±0.13 W/m·K, respectively, and for human clotted blood are (3.5±0.8)×103 J/kg·K and 0.59±0.11 W/m·K, respectively. Measurements of the acousto-mechanical and thermal properties of clotted blood can be helpful in theoretical modeling of ultrasound hyperthermia in ultrasound-assisted thrombolysis and other high-intensity focused ultrasound applications. PMID:16838520

  12. Thrombus resolution and hemodynamic recovery using ultrasound-accelerated thrombolysis in acute pulmonary embolism.

    PubMed

    Kennedy, Robert J; Kenney, Hai H; Dunfee, Brian L

    2013-06-01

    To evaluate retrospectively the safety profile and clinical success of ultrasound-accelerated thrombolysis for acute pulmonary embolism (PE) with a standard lytic infusion protocol. A retrospective study was performed at a single center treating patients with acute PE between October 2009 and April 2012. On diagnosis of submassive or massive PE by pulmonary computed tomography angiography or ventilation/perfusion scan, all patients received anticoagulation and treatment using the EkoSonic endovascular system (EKOS Corporation, Bothell, Washington). The ultrasound-accelerated thrombolytic infusion catheters were placed into the affected pulmonary arteries to facilitate administration of recombinant tissue plasminogen activator at 0.5-1.0mg/h/catheter. Treatment of 60 patients (35 men, 25 women; age 61 y±16; 53 bilateral PE; 48 submassive PE) resulted in complete thrombus clearance (≥90%) in 57% and near-complete (50%-90%) clearance in 41% of patients after infusion of 35.1 mg±11.1 of recombinant tissue plasminogen activator over 19.6 hours±6.0. Measurements before and after treatment showed a decrease in pulmonary artery pressure (47 mm Hg±15 to 38 mm Hg±12 [systolic], P<.001) and Miller score (25±3 to 17±6, P<.001). There were 57 patients who survived to discharge. All three patients who died in the hospital presented with massive PE. On 90-day follow-up, 56 patients (93%) were alive. The current study demonstrates effectiveness and safety of ultrasound-accelerated thrombolysis in patients with acute PE with a large thrombus burden. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  13. Reduced clot debris size using standing waves formed via high intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Guo, Shifang; Du, Xuan; Wang, Xin; Lu, Shukuan; Shi, Aiwei; Xu, Shanshan; Bouakaz, Ayache; Wan, Mingxi

    2017-09-01

    The feasibility of utilizing high intensity focused ultrasound (HIFU) to induce thrombolysis has been demonstrated previously. However, clinical concerns still remain related to the clot debris produced via fragmentation of the original clot potentially being too large and hence occluding downstream vessels, causing hazardous emboli. This study investigates the use of standing wave fields formed via HIFU to disintegrate the thrombus while achieving a reduced clot debris size in vitro. The results showed that the average diameter of the clot debris calculated by volume percentage was smaller in the standing wave mode than in the travelling wave mode at identical ultrasound thrombolysis settings. Furthermore, the inertial cavitation dose was shown to be lower in the standing wave mode, while the estimated cavitation bubble size distribution was similar in both modes. These results show that a reduction of the clot debris size with standing waves may be attributed to the particle trapping of the acoustic potential well which contributed to particle fragmentation.

  14. Ultrasound enhanced thrombolysis: Clinical evidence

    NASA Astrophysics Data System (ADS)

    Alexandrov, Andrei V.

    2005-04-01

    Phase II CLOTBUST randomized clinical trial (Houston, Barcelona, Edmonton, Calgary) evaluated patients with acute ischemic stroke due to intracranial occlusion and treated with intravenous tissue plasminogen activator (TPA) within 3 h of symptom onset. Randomization: monitoring with pulsed wave 2 MHz transcranial Doppler (TCD) (Target) or placebo monitoring (Control). Safety: symptomatic bleeding to the brain (sICH). Primary end-point: complete recanalization on TCD or dramatic clinical recovery by the total NIHSS score <3, or improvement by >10 NIHSS points within 2 hours after TPA bolus. All projected 126 patients were randomized 1:1 to target (median NIHSS 16) or control (NIHSS 17). sICH: 4.8% Target, 4.8% Controls. Primary end-point was achieved by 31 (49%, Target) versus 19 (30%, Control), p<0.03. At 3 months, 22 (42% Target) and 14 (29% Control) patients achieved favorable outcomes. Continuous TCD monitoring of intracranial occlusion safely augments TPA-induced arterial recanalization, and 2 MHz diagnostic ultrasound has a positive biological activity that aids systemic thrombolytic therapy. For the first time in clinical medicine, the CLOTBUST trial provides the evidence that ultrasound enhances thrombolytic activity of a drug in humans thereby confirming intense multi-disciplinary experimental research conducted worldwide for the past 30 years.

  15. Safety and Efficacy of Catheter Direct Thrombolysis in Management of Acute Iliofemoral Deep Vein Thrombosis: A Systematic Review.

    PubMed

    Elbasty, Ahmed; Metcalf, James

    2017-12-01

    Catheter direct thrombolysis (CDT) has been shown to be an effective treatment for deep venous thrombosis. The objective of the review is to improve safety and efficacy of the CDT by using ward based protocol, better able to predict complications and treatment outcome through monitoring of haemostatic parameters and clinical observation during thrombolysis procedure. MEDLINE, EMBASE, CENTRAL and Web of Science were searched for all articles on deep venous thrombosis, thrombolysis and correlations of clinical events (bleeding, successful thrombolysis) during thrombolysis with hemostatic parameters to March 2016. The risk of bias in included studies was assessed by Cochrane Collaboration's tool and Cochrane Risk of Bias Assessment Tool: for Non-Randomized Studies of Interventions. Twenty-four studies were included in the review and we found that improving safety and efficacy of CDT by using ward based protocol depending on eight factors; strict patient selection criteria, types of fibrinolytic drugs, mode of fibrinolytic drug injection, biochemical markers monitoring (fibrinogen, D-dimer, activated partial thromboplastin time, plasminogen activator inhibitor-1), timing of intervention, usage of intermittent pneumatic calf, ward monitoring and thrombolysis imaging assessment (intravascular ultrasound). These factors may help to improve safety and efficacy by reducing total thrombolytic drug dosage and at the same time ensure successful lysis. There is a marked lack of randomized controlled trials discussing the safety and efficacy of catheter direct thrombolysis. CDT can be performed safely and efficiently in clinical ward, providing that careful nursing, biochemical monitoring, proper selection and mode of infusion of fibrinolytic drugs, usage of Intermittent pneumatic calf and adequate thrombolysis imaging assessment are ensured.

  16. Thrombolysis in Acute Ischaemic Stroke: An Update

    PubMed Central

    Robinson, Thompson; Zaheer, Zahid; Mistri, Amit K.

    2011-01-01

    Stroke is a major cause of mortality and morbidity, and thrombolysis has served as a catalyst for major changes in the management of acute ischaemic stroke. Intravenous alteplase (recombinant tissue plasminogen activator) is the only approved thrombolytic agent at present indicated for acute ischaemic stoke. While the licensed time window extends to 3h from symptom onset, recent data suggest that the trial window can be extended up to 4.5 h with overall benefit. Nonetheless, 'time is brain' and every effort must be made to reduce the time delay to thrombolysis. Intracranial haemorrhage is the major complication associated with thrombolysis, and key factors increasing risk of haemorrhage include increasing age, high blood pressure, diabetes and stroke severity. Currently, there is no direct evidence to support thrombolysis in patients >80 years of age, with a few case series indicating no overt harm. Identification of viable penumbra based on computed tomography/magnetic resonance imaging may allow future extension of the time window. Adjuvant transcranial Doppler ultrasound has the potential to improve reperfusion rates. While intra-arterial thrombolysis has been in vogue for a few decades, there is no clear advantage over intravenous thrombolysis. The evidence base for thrombolysis in specific situations (e.g. dissection, pregnancy) is inadequate, and individualized decisions are needed, with a clear indication to the patient/carer about the lack of direct evidence, and the risk-benefit balance. Patient-friendly information leaflets may facilitate the process of consent for thrombolysis. This article summarizes the recent advances in thrombolysis for acute ischaemic stroke. Key questions faced by clinicians during the decision-making process are answered based on the evidence available. PMID:23251746

  17. Impact of Transcranial Doppler Ultrasound on Logistics and Outcomes in Stroke Thrombolysis: Results From the SITS-ISTR.

    PubMed

    Mazya, Michael V; Ahmed, Niaz; Azevedo, Elsa; Davalos, Antoni; Dorado, Laura; Karlinski, Michal; Lorenzano, Svetlana; Neumann, Jiří; Toni, Danilo; Moreira, Tiago P

    2018-07-01

    Diagnostic transcranial Doppler ultrasound (TCD) is commonly used in patients with acute stroke before or during treatment with intravenous thrombolysis (IVT). We aimed to assess how much TCD delays IVT initiation and whether TCD influences outcomes. We analyzed data from the SITS-ISTR (Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register) collected from December 2002 to December 2011. Outcomes were door-to-needle time, symptomatic intracerebral hemorrhage, functional outcome per the modified Rankin Scale, and mortality at 3 months. In hospitals performing any TCD pre-IVT, 1701 of 11 265 patients (15%) had TCD before IVT initiation. Door-to-needle time was higher in patients with pre-IVT TCD (74 versus 60 minutes; P <0.001). At hospitals performing any TCD during IVT infusion, of 9044 patients with IVT, 747 were examined with TCD during IVT. No treatment delay was seen with TCD during IVT. After multivariate adjustment, TCD during IVT was independently associated with modestly increased excellent functional outcome (modified Rankin Scale, 0-1; adjusted odds ratio, 1.28; 95% confidence interval, 1.06-1.55; P =0.012) and lower mortality (adjusted odds ratio, 0.73; 95% confidence interval, 0.55-0.95; P =0.022). We recommend that TCD, if performed, should be done during IVT infusion, to avoid treatment delay. The association of hyperacute TCD with beneficial outcomes suggests potential impact on patient management, which warrants further study. © 2018 American Heart Association, Inc.

  18. Experimental validation of a finite-difference model for the prediction of transcranial ultrasound fields based on CT images

    NASA Astrophysics Data System (ADS)

    Bouchoux, Guillaume; Bader, Kenneth B.; Korfhagen, Joseph J.; Raymond, Jason L.; Shivashankar, Ravishankar; Abruzzo, Todd A.; Holland, Christy K.

    2012-12-01

    The prevalence of stroke worldwide and the paucity of effective therapies have triggered interest in the use of transcranial ultrasound as an adjuvant to thrombolytic therapy. Previous studies have shown that 120 kHz ultrasound enhanced thrombolysis and allowed efficient penetration through the temporal bone. The objective of our study was to develop an accurate finite-difference model of acoustic propagation through the skull based on computed tomography (CT) images. The computational approach, which neglected shear waves, was compared with a simple analytical model including shear waves. Acoustic pressure fields from a two-element annular array (120 and 60 kHz) were acquired in vitro in four human skulls. Simulations were performed using registered CT scans and a source term determined by acoustic holography. Mean errors below 14% were found between simulated pressure fields and corresponding measurements. Intracranial peak pressures were systematically underestimated and reflections from the contralateral bone were overestimated. Determination of the acoustic impedance of the bone from the CT images was the likely source of error. High correlation between predictions and measurements (R2 = 0.93 and R2 = 0.88 for transmitted and reflected waves amplitude, respectively) demonstrated that this model is suitable for a quantitative estimation of acoustic fields generated during 40-200 kHz ultrasound-enhanced ischemic stroke treatment.

  19. Safety and Efficacy of Catheter Direct Thrombolysis in Management of Acute Iliofemoral Deep Vein Thrombosis: A Systematic Review

    PubMed Central

    Elbasty, Ahmed; Metcalf, James

    2017-01-01

    Purpose Catheter direct thrombolysis (CDT) has been shown to be an effective treatment for deep venous thrombosis. The objective of the review is to improve safety and efficacy of the CDT by using ward based protocol, better able to predict complications and treatment outcome through monitoring of haemostatic parameters and clinical observation during thrombolysis procedure. Materials and Methods MEDLINE, EMBASE, CENTRAL and Web of Science were searched for all articles on deep venous thrombosis, thrombolysis and correlations of clinical events (bleeding, successful thrombolysis) during thrombolysis with hemostatic parameters to March 2016. The risk of bias in included studies was assessed by Cochrane Collaboration’s tool and Cochrane Risk of Bias Assessment Tool: for Non-Randomized Studies of Interventions. Results Twenty-four studies were included in the review and we found that improving safety and efficacy of CDT by using ward based protocol depending on eight factors; strict patient selection criteria, types of fibrinolytic drugs, mode of fibrinolytic drug injection, biochemical markers monitoring (fibrinogen, D-dimer, activated partial thromboplastin time, plasminogen activator inhibitor-1), timing of intervention, usage of intermittent pneumatic calf, ward monitoring and thrombolysis imaging assessment (intravascular ultrasound). These factors may help to improve safety and efficacy by reducing total thrombolytic drug dosage and at the same time ensure successful lysis. There is a marked lack of randomized controlled trials discussing the safety and efficacy of catheter direct thrombolysis. Conclusion CDT can be performed safely and efficiently in clinical ward, providing that careful nursing, biochemical monitoring, proper selection and mode of infusion of fibrinolytic drugs, usage of Intermittent pneumatic calf and adequate thrombolysis imaging assessment are ensured. PMID:29354622

  20. Yield and accuracy of urgent combined carotid/transcranial ultrasound testing in acute cerebral ischemia.

    PubMed

    Chernyshev, Oleg Y; Garami, Zsolt; Calleja, Sergio; Song, Joon; Campbell, Morgan S; Noser, Elizabeth A; Shaltoni, Hashem; Chen, Chin-I; Iguchi, Yasuyuki; Grotta, James C; Alexandrov, Andrei V

    2005-01-01

    We routinely perform an urgent bedside neurovascular ultrasound examination (NVUE) with carotid/vertebral duplex and transcranial Doppler (TCD) in patients with acute cerebral ischemia. We aimed to determine the yield and accuracy of NVUE to identify lesions amenable for interventional treatment (LAITs). NVUE was performed with portable carotid duplex and TCD using standardized fast-track (<15 minutes) insonation protocols. Digital subtraction angiography (DSA) was the gold standard for identifying LAIT. These lesions were defined as proximal intra- or extracranial occlusions, near-occlusions, > or =50% stenoses or thrombus in the symptomatic artery. One hundred and fifty patients (70 women, mean age 66+/-15 years) underwent NVUE at median 128 minutes after symptom onset. Fifty-four patients (36%) received intravenous or intra-arterial thrombolysis (median National Institutes of Health Stroke Scale (NIHSS) score 14, range 4 to 29; 81% had NIHSS > or =10 points). NVUE demonstrated LAITs in 98% of patients eligible for thrombolysis, 76% of acute stroke patients ineligible for thrombolysis (n=63), and 42% in patients with transient ischemic attack (n=33), P<0.001. Urgent DSA was performed in 30 patients on average 230 minutes after NVUE. Compared with DSA, NVUE predicted LAIT presence with 100% sensitivity and 100% specificity, although individual accuracy parameters for TCD and carotid duplex specific to occlusion location ranged 75% to 96% because of the presence of tandem lesions and 10% rate of no temporal windows. Bedside neurovascular ultrasound examination, combining carotid/vertebral duplex with TCD yields a substantial proportion of LAITs in excellent agreement with urgent DSA.

  1. Noninvasive treatment of deep venous thrombosis using pulsed ultrasound cavitation therapy (histotripsy) in a porcine model.

    PubMed

    Maxwell, Adam D; Owens, Gabe; Gurm, Hitinder S; Ives, Kimberly; Myers, Daniel D; Xu, Zhen

    2011-03-01

    This study evaluated histotripsy as a noninvasive, image-guided method of thrombolysis in a porcine model of deep vein thrombosis. Histotripsy therapy uses short, high-intensity, focused ultrasound pulses to cause mechanical breakdown of targeted soft tissue by acoustic cavitation, which is guided by real-time ultrasound imaging. This is an in vivo feasibility study of histotripsy thrombolysis. Acute thrombi were formed in the femoral vein of juvenile pigs weighing 30-40 kg by balloon occlusion with two catheters and thrombin infusion. A 10-cm-diameter 1-MHz focused transducer was used for therapy. An 8-MHz ultrasound imager was used to align the clot with the therapy focus. Therapy consisted of five cycle pulses delivered at a rate of 1 kHz and peak negative pressure between 14 and 19 MPa. The focus was scanned along the long axis of the vessel to treat the entire visible clot during ultrasound exposure. The targeted region identified by a hyperechoic cavitation bubble cloud was visualized via ultrasound during treatment. Thrombus breakdown was apparent as a decrease in echogenicity within the vessel in 10 of 12 cases and in 7 cases improved flow through the vein as measured by color Doppler. Vessel histology found denudation of vascular endothelium and small pockets of hemorrhage in the vessel adventitia and underlying muscle and fatty tissue, but perforation of the vessel wall was never observed. The results indicate histotripsy has potential for development as a noninvasive treatment for deep vein thrombosis. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  2. High-intensity focused ultrasound (HIFU) for dissolution of clots in a rabbit model of embolic stroke.

    PubMed

    Burgess, Alison; Huang, Yuexi; Waspe, Adam C; Ganguly, Milan; Goertz, David E; Hynynen, Kullervo

    2012-01-01

    It is estimated that only 2-6% of patients receive thrombolytic therapy for acute ischemic stroke suggesting that alternative therapies are necessary. In this study, we investigate the potential for high intensity focused ultrasound (HIFU) to initiate thrombolysis in an embolic model of stroke. Iron-loaded blood clots were injected into the middle cerebral artery (MCA) of New Zealand White rabbits, through the internal carotid artery and blockages were confirmed by angiography. MRI was used to localize the iron-loaded clot and target the HIFU beam for treatment. HIFU pulses (1.5 MHz, 1 ms bursts, 1 Hz pulse repetition frequency, 20 s duration) were applied to initiate thrombolysis. Repeat angiograms and histology were used to assess reperfusion and vessel damage. Using 275 W of acoustic power, there was no evidence of reperfusion in post-treatment angiograms of 3 rabbits tested. In a separate group of animals, 415 W of acoustic power was applied and reperfusion was observed in 2 of the 4 (50%) animals treated. In the last group of animals, acoustic power was further increased to 550 W, which led to the reperfusion in 5 of 7 (∼70%) animals tested. Histological analysis confirmed that the sonicated vessels remained intact after HIFU treatment. Hemorrhage was detected outside of the sonication site, likely due to the proximity of the target vessel with the base of the rabbit skull. These results demonstrate the feasibility of using HIFU, as a stand-alone method, to cause effective thrombolysis without immediate damage to the targeted vessels. HIFU, combined with imaging modalities used to identify and assess stroke patients, could dramatically reduce the time to achieve flow restoration in patients thereby significantly increasing the number of patients which benefit from thrombolysis treatments.

  3. High-Intensity Focused Ultrasound (HIFU) for Dissolution of Clots in a Rabbit Model of Embolic Stroke

    PubMed Central

    Burgess, Alison; Huang, Yuexi; Waspe, Adam C.; Ganguly, Milan; Goertz, David E.; Hynynen, Kullervo

    2012-01-01

    It is estimated that only 2–6% of patients receive thrombolytic therapy for acute ischemic stroke suggesting that alternative therapies are necessary. In this study, we investigate the potential for high intensity focused ultrasound (HIFU) to initiate thrombolysis in an embolic model of stroke. Iron-loaded blood clots were injected into the middle cerebral artery (MCA) of New Zealand White rabbits, through the internal carotid artery and blockages were confirmed by angiography. MRI was used to localize the iron-loaded clot and target the HIFU beam for treatment. HIFU pulses (1.5 MHz, 1 ms bursts, 1 Hz pulse repetition frequency, 20 s duration) were applied to initiate thrombolysis. Repeat angiograms and histology were used to assess reperfusion and vessel damage. Using 275 W of acoustic power, there was no evidence of reperfusion in post-treatment angiograms of 3 rabbits tested. In a separate group of animals, 415 W of acoustic power was applied and reperfusion was observed in 2 of the 4 (50%) animals treated. In the last group of animals, acoustic power was further increased to 550 W, which led to the reperfusion in 5 of 7 (∼70%) animals tested. Histological analysis confirmed thatthe sonicated vessels remained intact after HIFU treatment. Hemorrhage was detected outside of the sonication site, likely due to the proximity of the target vessel with the base of the rabbit skull. These results demonstrate the feasibility of using HIFU, as a stand-alone method, to cause effective thrombolysis without immediate damage to the targeted vessels. HIFU, combined with imaging modalities used to identify and assess stroke patients, could dramatically reduce the time to achieve flow restoration in patients thereby significantly increasing the number of patients which benefit from thrombolysis treatments. PMID:22870315

  4. High-Intensity Focused Ultrasound Therapy: an Overview for Radiologists

    PubMed Central

    Kim, Young-sun; Choi, Min Joo; Lim, Hyo Keun; Choi, Dongil

    2008-01-01

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments. PMID:18682666

  5. Ultrasound active nanoscaled lipid formulations for thrombus lysis.

    PubMed

    Becker, Andreas; Marxer, Elena; Brüssler, Jana; Hoormann, Anne Sophia; Kuhnt, Daniela; Bakowsky, Udo; Nimsky, Christopher

    2011-04-01

    In the present study, we investigated the sonothrombolytic effect of new nanoscaled lipid formulations in human blood clots, using diagnostic ultrasound. Human blood clots of 1 ml were incubated with 1 μl of the different lipid dispersions DPPC/CH, DPPC/PEG40S, DSPC/PEG40S and the commercially available ultrasound contrast agent SonoVue®. Clots were stored for 3 days at 5 °C to obtain maximal clot retraction and lytic resistance. Each clot weight was determined before and after continuous insonation for 1h of insonation at 1.4 MHz. The pressure in the insonation chamber was 80 mm Hg to mimic middle arterial blood pressure. There were no significant differences in thrombus weight before insonation. All nanoscaled formulations and SonoVue® were able to reduce thrombus weight compared to the weight loss of clots that were not insonated but kept under pressure for one hour (p < 0.001). We found a highly significant weight reduction with DSPC/PEG40S compared to SonoVue® (p = 0.007). Nanoscaled DSPC/PEG40S dispersion could be a promising formulation in ultrasound enhanced thrombolysis even without thrombolytic drugs. Stable cavitation is a crucial parameter in fragmentation of thrombus architecture. Further studies of physicochemical properties of DSPC/PEG40S are necessary to corroborate our hypothesis. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. An Investigation of High Intensity Focused Ultrasound Thrombolysis

    NASA Astrophysics Data System (ADS)

    Wright, Cameron; Hynynen, Kullervo; Goertz, David

    2011-09-01

    Investigations into high intensity focused ultrasound (HIFU) thrombolysis in vitro and in vivo in a rabbit femoral artery thrombus model were performed. A 1.51 MHz focused transducer was used to treat clots with pulse lengths of 1-10 ms, acoustic powers of 1-300 W and exposure durations of 5-20 s. Our measurements indicate the creation of acoustic radiation force induced clot displacements are insufficient to mechanically fractionate clots, despite reaching displacements >100 μm. Only under the presence of inertial cavitation was HIFU able to disrupt clots. Cavitation thresholds of 160 W in vitro and 215 W in vivo were observed. In vitro, clots insonified at powers above the cavitation threshold eroded regions up to 2.5× the transducer beam width. Successful recanalization in vivo occurred in 5/20 cases for 1ms pulses at powers >215 W. 10 ms pulses created high incidences of symptomatic bleeding while 1 ms pulses did not. These results demonstrate treatment feasibility in vivo, although further work is required to understand the influence of different acoustic parameters on treatment outcome.

  7. Investigating Interactions between Ultrasound Stimulated Microbubbles and the Fibrin Network of Blood Clots

    NASA Astrophysics Data System (ADS)

    Acconcia, Christopher N.

    The occlusion of blood vessels by thrombus is a major cause of mortality and morbidity in cardiovascular diseases such as deep vein thrombosis, myocardial infarction and ischemic stroke. In these contexts, prompt restoration of blood flow is of the utmost importance and is poorly addressed by current methods in many cases. For example, the treatment standard for ischemic stroke is administration of the thrombolytic agent tissue plasminogen activator, which is only minimally effective and has associated safety issues. There is, therefore, a need for the development of alternative recanalization strategies and amongst these, bubble mediated sonothrombolysis (thrombolysis by ultrasound) has emerged as a promising approach. Though it is well established that ultrasound stimulated microbubbles can potentiate the lysis of blood clots, the mechanisms are not well understood and this lack of understanding is a hindrance to the development of improved ultrasound exposure strategies. This thesis has revealed insights into the mechanisms of bubble mediated sonothrombolysis which can be used to guide the development of improved exposure strategies and contrast agents (i.e. bubble sizes) for sonothrombolysis treatments. The experimental approach involved fast frame optical imaging of ultrasound stimulated microbubbles interacting with clots, and two-photon fluorescence imaging of clots following ultrasound exposure. It was demonstrated that bubbles can penetrate fibrin clots, disrupt the fibrin network, generate patent tunnels, enhance the transport of fluid into the clot and induce clot boundary displacements. Furthermore, the occurrence and extent of these therapeutically relevant effects were shown to be highly dependent on pulse length and bubble size: longer pulses and larger bubbles were associated with greater disruption of fibrin networks and greater fluid transport distances. Finally, it was shown that bubbles can induce the ejection of erythrocytes from blood clots and produce advanced erosion effects which depend on ultrasound exposure conditions.

  8. Edaravone, a Synthetic Free Radical Scavenger, Enhances Alteplase-Mediated Thrombolysis

    PubMed Central

    Kikuchi, Kiyoshi; Setoyama, Kentaro; Nagasato, Tomoka; Terashi, Takuto; Ueda, Koki; Nakanishi, Kazuki; Otsuka, Shotaro; Miura, Naoki; Sameshima, Hisayo; Hosokawa, Kazuya; Harada, Yoichiro; Shrestha, Binita; Yamamoto, Mika; Morimoto-Yamashita, Yoko; Kikuchi, Haruna; Kamikokuryo, Chinatsu; Morioka, Motohiro; Tanaka, Eiichiro

    2017-01-01

    The combination of alteplase, a recombinant tissue plasminogen activator, and edaravone, an antioxidant, reportedly enhances recanalization after acute ischemic stroke. We examined the influence of edaravone on the thrombolytic efficacy of alteplase by measuring thrombolysis using a newly developed microchip-based flow-chamber assay. Rat models of embolic cerebral ischemia were treated with either alteplase or alteplase-edaravone combination therapy. The combination therapy significantly reduced the infarct volume and improved neurological deficits. Human blood samples from healthy volunteers were exposed to edaravone, alteplase, or a combination of alteplase and edaravone or hydrogen peroxide. Whole blood was perfused over a collagen- and thromboplastin-coated microchip; capillary occlusion was monitored with a video microscope and flow-pressure sensor. The area under the curve (extent of thrombogenesis or thrombolysis) at 30 minutes was 69.9% lower in the edaravone-alteplase- than alteplase-treated group. The thrombolytic effect of alteplase was significantly attenuated in the presence of hydrogen peroxide, suggesting that oxidative stress might hinder thrombolysis. D-dimers were measured to evaluate these effects in human platelet-poor plasma samples. Although hydrogen peroxide significantly decreased the elevation of D-dimers by alteplase, edaravone significantly inhibited the decrease. Edaravone enhances alteplase-mediated thrombolysis, likely by preventing oxidative stress, which inhibits fibrinolysis by alteplase in thrombi. PMID:29259732

  9. Arrhenius temperature dependence of in vitro tissue plasminogen activator thrombolysis.

    PubMed

    Shaw, George J; Dhamija, Ashima; Bavani, Nazli; Wagner, Kenneth R; Holland, Christy K

    2007-06-07

    Stroke is a devastating disease and a leading cause of death and disability. Currently, the only FDA approved therapy for acute ischemic stroke is the intravenous administration of the thrombolytic medication, recombinant tissue plasminogen activator (tPA). However, this treatment has many contraindications and can have dangerous side effects such as intra-cerebral hemorrhage. These treatment limitations have led to much interest in potential adjunctive therapies, such as therapeutic hypothermia (T

  10. Arrhenius temperature dependence of in vitro tissue plasminogen activator thrombolysis

    NASA Astrophysics Data System (ADS)

    Shaw, George J.; Dhamija, Ashima; Bavani, Nazli; Wagner, Kenneth R.; Holland, Christy K.

    2007-06-01

    Stroke is a devastating disease and a leading cause of death and disability. Currently, the only FDA approved therapy for acute ischemic stroke is the intravenous administration of the thrombolytic medication, recombinant tissue plasminogen activator (tPA). However, this treatment has many contraindications and can have dangerous side effects such as intra-cerebral hemorrhage. These treatment limitations have led to much interest in potential adjunctive therapies, such as therapeutic hypothermia (T <= 35 °C) and ultrasound enhanced thrombolysis. Such interest may lead to combining these therapies with tPA to treat stroke, however little is known about the effects of temperature on the thrombolytic efficacy of tPA. In this work, we measure the temperature dependence of the fractional clot mass loss Δm(T) resulting from tPA exposure in an in vitro human clot model. We find that the temperature dependence is well described by an Arrhenius temperature dependence with an effective activation energy Eeff of 42.0 ± 0.9 kJ mole-1. Eeff approximates the activation energy of the plasminogen-to-plasmin reaction of 48.9 kJ mole-1. A model to explain this temperature dependence is proposed. These results will be useful in predicting the effects of temperature in future lytic therapies.

  11. Catheter-directed, ultrasound-assisted thrombolysis is a safe and effective treatment for pulmonary embolism, even in high-risk patients.

    PubMed

    Lee, Kristen A; Cha, Andrew; Kumar, Mark H; Rezayat, Combiz; Sales, Clifford M

    2017-03-01

    We sought to assess the early success and safety of catheter-directed, ultrasound-assisted (CDUA) thrombolysis for acute pulmonary embolism (PE) in patients deemed to be "high risk" for thrombolytic therapy. A retrospective evaluation of patients who underwent CDUA pulmonary thrombolysis in our practice during 39 months is reported. There were 91 patients considered, all of whom presented with acute PE as diagnosed by computed tomography angiography. The ratio of the right ventricle to left ventricle diameter (RV axial :LV axial ) was noted, as were preprocedure pulmonary artery pressures (PAPs). Demographic data, significant medical history, and procedure details were recorded. Standard thrombolysis protocol was followed (1 mg of tissue plasminogen activator per hour per catheter after an initial 2-mg bolus per catheter). Minitab 17 (Minitab Inc, State College, PA) was used for data analysis. There were 91 patients who had a computed tomography diagnosis of acute PE and pulmonary hypertension (PAP >25 mm Hg). Seventeen patients (19%) were deemed to be at high risk for bleeding, predicted by recent hemorrhage, major surgery within 3 weeks, acute myocardial infarction, and cardiac arrest with cardiopulmonary resuscitation within 1 week. The high-risk patients in our study were noted to have higher RV:LV ratios and lower oxygen saturations on admission (P < .05). On computed tomography angiography, the mean pretherapy RV axial :LV axial ratio was 1.5 ± 0.4. The mean pretherapy PAP was 56.2 ± 15.2 mm Hg. After 18.5 ± 3.5 hours of thrombolysis, the mean post-therapy PAP was 34.3 ± 10.4 mm Hg, with a pressure drop of 21.9 ± 4.8 mm Hg (39% decrease; P < .001). In total, seven patients (8%) suffered bleeding complications that required intervention-four gastrointestinal bleeds, a rectus sheath hematoma, and one gross hematuria. Three of the seven complications occurred in the high-risk group (3/17) and the other four in the general population of patients (4/74; P = .118). Minor bleeding complications (n = 14 [15%]) did not require intervention and included puncture site hematomas, ecchymosis, and mild traumatic hematuria. Considering all bleeding complications, increasing RV axial :LV axial ratio was a predictor of any bleeding complication, independent of all risk factors (P = .005). CDUA thrombolysis for acute PE effectively reduced mean PAPs. Given the low incidence of major bleeding complications, even in those deemed to be clinically at high risk for bleeding, we additionally conclude that this procedure can be performed safely. Although larger studies with longer follow-up are necessary, CDUA pulmonary thrombolysis for the management of acute submassive PE appears to be effective in decreasing right-sided heart strain and can be performed with an acceptable risk profile. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. Potential and problems in ultrasound-responsive drug delivery systems

    PubMed Central

    Zhao, Ying-Zheng; Du, Li-Na; Lu, Cui-Tao; Jin, Yi-Guang; Ge, Shu-Ping

    2013-01-01

    Ultrasound is an important local stimulus for triggering drug release at the target tissue. Ultrasound-responsive drug delivery systems (URDDS) have become an important research focus in targeted therapy. URDDS include many different formulations, such as microbubbles, nanobubbles, nanodroplets, liposomes, emulsions, and micelles. Drugs that can be loaded into URDDS include small molecules, biomacromolecules, and inorganic substances. Fields of clinical application include anticancer therapy, treatment of ischemic myocardium, induction of an immune response, cartilage tissue engineering, transdermal drug delivery, treatment of Huntington’s disease, thrombolysis, and disruption of the blood–brain barrier. This review focuses on recent advances in URDDS, and discusses their formulations, clinical application, and problems, as well as a perspective on their potential use in the future. PMID:23637531

  13. Transjugular Intrahepatic Portosystemic Shunt, Mechanical Aspiration Thrombectomy, and Direct Thrombolysis in the Treatment of Acute Portal and Superior Mesenteric Vein Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Bovio, Giulio

    2007-09-15

    A patient was admitted because of severe abdominal pain, anorexia, and intestinal bleeding. Contrast-enhanced multidetector computed tomography demonstrated acute portal and superior mesenteric vein thrombosis (PSMVT). The patient was treated percutaneously with transjugular intrahepatic portosystemic shunt (TIPS), mechanical aspiration thrombectomy, and direct thrombolysis, and 1 week after the procedure, complete patency of the portal and superior mesenteric veins was demonstrated. TIPS, mechanical aspiration thrombectomy, and direct thrombolysis together are promising endovascular techniques for the treatment of symptomatic acute PSMVT.

  14. Application of Cavitation Promoting Surfaces in Management of Acute Ischemic Stroke

    PubMed Central

    Soltani, Azita

    2012-01-01

    High frequency, low intensity ultrasound has the potential to accelerate the clearance of thrombotic occlusion in the absence of cavitation. At high frequency ultrasound, high acoustic pressures, > 5.2 MPa, are required to generate cavitation in thrombus. The focus of this study was to reduce the cavitation threshold by applying materials with appropriate nucleation sites at the transducer-thrombus boundary to further augment sonothrombolysis. Heterogeneous and homogenous nucleation sites were generated on the outer surface of a polyimide tube (PI) using microfringed (MPI) and laser induced (LPI) microcavities. The cavitation threshold of these materials was determined using a passive cavitation detection system. Furthermore, the biological impact of both materials was investigated in vitro. The results revealed that both MPI and LPI have the potential to induce cavitation at acoustic pressure levels as low as 2.3 MPa. In the presence of cavitation, thrombolysis rate could be enhanced by up to 2 times without any evidence of hemolysis that is generally associated with cavitation activities in blood. A prototype ultrasonic catheter operating at 1.7MHz frequency and acoustic pressure of 2.3MPa with either of MPI or LPI could be considered as a viable option for treatment of acute ischemic stroke. PMID:23141666

  15. Development of endovascular vibrating polymer actuator probe for mechanical thrombolysis: a phantom study.

    PubMed

    Choi, Seung Hong; Yoon, Bye-Ri; Oh, Jin Sun; Han, Moon Hee; Lee, Jang Yeol; Cho, Hye Rim; Kim, Moon June; Rhee, Kyehan; Jho, Jae Young

    2011-01-01

    In this study, we propose a new method for enhancement of intraarterial thrombolysis using an ionic polymer-metal composite (IPMC) actuator. The purpose of this study was to test the mechanical thrombolysis efficiency of IPMC actuators and evaluate the endovascular vibrating polymer actuator probe for mechanical thrombolysis in a phantom model; 2 × 1 × 15 mm (2 mm in width, 1 mm in thickness, and 15 mm in length) and 0.8 × 0.8 × 10 mm (0.8 mm in width, 0.8 mm in thickness, and 10 mm in length) IPMC actuators were fabricated by stacking five and four Nafion-117 films, respectively. We manufactured the endovascular vibrating polymer actuator probe, for which thrombolysis efficiency was tested in a vascular phantom. The phantom study using 2 × 1 × 15 mm IPMC actuators showed that 5 Hz actuation is the optimal frequency for thrombolysis under both 2 and 3 V, when blood clot was not treated with rtPA, and when exposed to rtPA, IPMC actuators under the optimized condition (3 V, 5 Hz, and 5 min) significantly increased the thrombolysis degree compared with control and other experimental groups (p < 0.05). In addition, 0.8 × 0.8 × 10 mm IPMC actuators also revealed a significantly higher thrombolysis degree under the optimized condition than the control and rtPA only groups (p < 0.05). Finally, the fabricated probe using 0.8 × 0.8 × 10 mm IPMC actuators also incurred higher thrombolysis degree under the optimized condition than the control and rtPA only groups (p < 0.05). A vibrating polymer actuator probe is a feasible device for intravascular thrombolysis, and further study in an animal model is warranted.

  16. Steering Microbubbles in Physiologically Realistic Flows Using the Bjerknes Force

    NASA Astrophysics Data System (ADS)

    Clark, Alicia; Aliseda, Alberto

    2017-11-01

    Ultrasound contrast agents (UCAs) are lipid-coated microbubbles that are used to increase contrast in ultrasound imaging due to their ability to scatter sound. Additionally, UCAs can be used in conjunction with ultrasound in medical applications such as targeted drug delivery and thrombolysis. These applications utilize the Bjerknes force, an ultrasound-induced force caused by the phase difference between the incoming ultrasound pressure wave and the microbubble volume oscillations. The dynamics of microbubbles under ultrasound excitation have been studied thoroughly in stagnant fluid baths; however, understanding of the fundamental physics of microbubbles in physiologically realistic flows is lacking. An in vitroexperiment that reproduces the dynamics (Reynolds and Womersley numbers) of a medium-sized blood vessel was used to explore the behavior of microbubbles. Using Lagrangian tracking, the trajectory of each individual bubble was reconstructed using information obtained from high speed imaging. The balance of hydrodynamic forces (lift, drag, added mass, etc.) against the primary Bjerknes force was analyzed. The results show that an increase in ultrasound pulse repetition frequency leads to a linear increase in the Bjerknes force and the increase in the force is quadratic with the amplitude of the excitation.

  17. Computational analysis of blood clot dissolution using a vibrating catheter tip.

    PubMed

    Lee, Jeong Hyun; Oh, Jin Sun; Yoon, Bye Ri; Choi, Seung Hong; Rhee, Kyehan; Jho, Jae Young; Han, Moon Hee

    2012-04-01

    We developed a novel concept of endovascular thrombolysis that employs a vibrating electroactive polymer actuator. In order to predict the efficacy of thrombolysis using the developed vibrating actuator, enzyme (plasminogen activator) perfusion into a clot was analyzed by solving flow fields and species transport equations considering the fluid structure interaction. In vitro thrombolysis experiments were also performed. Computational results showed that plasminogen activator perfusion into a clot was enhanced by actuator vibration at frequencies of 1 and 5 Hz. Plasminogen activator perfusion was affected by the actuator oscillation frequencies and amplitudes that were determined by electromechanical characteristics of a polymer actuator. Computed plasminogen activator perfused volumes were compared with experimentally measured dissolved clot volumes. The computed plasminogen activator perfusion volumes with threshold concentrations of 16% of the initial plasminogen activator concentration agreed well with the in vitro experimental data. This study showed the effectiveness of actuator oscillation on thrombolysis and the validity of the computational plasminogen activator perfusion model for predicting thrombolysis in complex flow fields induced by an oscillating actuator.

  18. Neuroprotective effect of combined ultrasound and microbubbles in a rat model of middle cerebral artery infarction

    NASA Astrophysics Data System (ADS)

    Fatar, M.; Griebe, M.; Stroick, M.; Kern, R.; Hennerici, M.; Meairs, S.

    2005-03-01

    Ultrasound-mediated microbubble thrombolysis (UMT) was performed in a middle cerebral artery occlusion model in rats to evaluate possible effects upon brain infarct volume, apoptosis, IL-6 and TNF-alpha levels, and disruption of the blood-brain barrier (BBB). The results show that infarct volume was significantly reduced (p<0.04) in the microbubble + ultrasound (MB + US) group as compared to control animals. The levels of IL-6 and TNF-alpha concentrations, as markers of tissue damage, were not significantly different. In trypan blue treated animals, no additional BBB disruption was observed for the UMT group. Likewise, there was no increase in apoptotic cell death outside the infarction area in animals treated with MB + US. The results demonstrate that UMT does not have a harmful effect upon ischemic stroke in a middle cerebral artery occlusion model of the rat. The significant reduction in brain infarction following insonation with ultrasound and microbubbles suggests a novel neuroprotective effect in ischemic stroke.

  19. Outcomes and predictors of failure of thrombolysis for iliofemoral deep venous thrombosis.

    PubMed

    Avgerinos, Efthymios D; Hager, Eric S; Naddaf, Abdallah; Dillavou, Ellen; Singh, Michael; Chaer, Rabih A

    2015-01-01

    Catheter-directed thrombolysis (CDT) with adjunctive mechanical techniques, when successful, is reported to alleviate symptoms of acute iliofemoral deep venous thrombosis (IFDVT) and to lower the occurrence of the post-thrombotic syndrome (PTS). This study aimed to determine longer term outcomes of catheter-based interventions for IFDVT and to identify predictors of immediate and mid-long-term failures that would guide optimal patient selection. Consecutive patients who underwent CDT or pharmacomechanical thrombolysis for IFDVT between May 2007 and March 2013 were identified from a prospectively maintained database. Assessment of predictors of immediate periprocedural failure was based on the degree of clot lysis (≤ 50% vs >50%) and 30-day recurrence of DVT. Long-term anatomic and clinical failures and outcomes were assessed by ultrasound imaging of the lysed segments and Villalta score (≥ 5 vs <5). Survival analysis was used to assess primary patency and PTS morbidity. Multivariate binary logistic and Cox regression models were used to determine predictors of anatomic and clinical failures. During the study period, 93 patients (118 limbs; mean age, 49.4 ± 16.2 years; 47 women) with symptoms averaging 11.1 ± 9.6 days in duration were treated with various combinations of CDT or pharmacomechanical thrombolysis; in 52 (56%), at least one iliocaval stent was deployed. Immediate treatment failure was seen in 11 patients (12%) predicted by the preoperative indication "phlegmasia" (odds ratio, 3.12; P = .042) and recent surgery (odds ratio, 19.6; P = .018). At a mean ultrasonographic follow-up of 16 ± 14 months (range, 1-65 months), six more patients sustained a rethrombosis, accounting for an overall 3-year primary patency of 72.1%. In the long-term model, loss of primary patency was associated with recent surgery (hazard ratio [HR], 4.04; P = .023), malignant disease (HR, 6.75; P = .016), and incomplete thrombolysis (≤ 50%) (HR, 5.83; P < .001). By stratification of PTS on the basis of postprocedure failures, at 2 years PTS occurred in 50.6% of patients and in 16.3% of patients without failure (P < .001). Thrombolysis for symptomatic IFDVT can achieve high rates of thrombus resolution and reduce long-term PTS morbidity on careful patient selection. Improved anatomic and clinical outcomes are associated with the completeness of thrombolysis. Copyright © 2015. Published by Elsevier Inc.

  20. Process improvement to enhance existing stroke team activity toward more timely thrombolytic treatment.

    PubMed

    Cho, Han-Jin; Lee, Kyung Yul; Nam, Hyo Suk; Kim, Young Dae; Song, Tae-Jin; Jung, Yo Han; Choi, Hye-Yeon; Heo, Ji Hoe

    2014-10-01

    Process improvement (PI) is an approach for enhancing the existing quality improvement process by making changes while keeping the existing process. We have shown that implementation of a stroke code program using a computerized physician order entry system is effective in reducing the in-hospital time delay to thrombolysis in acute stroke patients. We investigated whether implementation of this PI could further reduce the time delays by continuous improvement of the existing process. After determining a key indicator [time interval from emergency department (ED) arrival to intravenous (IV) thrombolysis] and conducting data analysis, the target time from ED arrival to IV thrombolysis in acute stroke patients was set at 40 min. The key indicator was monitored continuously at a weekly stroke conference. The possible reasons for the delay were determined in cases for which IV thrombolysis was not administered within the target time and, where possible, the problems were corrected. The time intervals from ED arrival to the various evaluation steps and treatment before and after implementation of the PI were compared. The median time interval from ED arrival to IV thrombolysis in acute stroke patients was significantly reduced after implementation of the PI (from 63.5 to 45 min, p=0.001). The variation in the time interval was also reduced. A reduction in the evaluation time intervals was achieved after the PI [from 23 to 17 min for computed tomography scanning (p=0.003) and from 35 to 29 min for complete blood counts (p=0.006)]. PI is effective for continuous improvement of the existing process by reducing the time delays between ED arrival and IV thrombolysis in acute stroke patients.

  1. Efficacy of Lower-Extremity Venous Thrombolysis in the Setting of Congenital Absence or Atresia of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganguli, Suvranu, E-mail: sganguli@partners.org; Kalva, Sanjeeva; Oklu, Rahmi

    Purpose: A rare but described risk factor for deep venous thrombosis (DVT), predominately in the young, is congenital agenesis or atresia of the inferior vena cava (IVC). The optimal management for DVT in this subset of patients is unknown. We evaluated the efficacy of pharmacomechanical catheter-directed thrombolysis (PCDT) followed by systemic anticoagulation in the treatment of acute lower-extremity DVT in the setting of congenital IVC agenesis or atresia. Materials and Methods: Between November of 2005 and May of 2010, six patients (three women [average age 21 years]) were referred to our department with acute lower-extremity DVT and subsequently found tomore » have IVC agenesis or atresia on magnetic resonance imaging. A standardized technique for PCDT (the Angiojet Rheolytic Thrombectomy System followed by the EKOS Microsonic Accelerated Thrombolysis System) was used for all subjects. Successful thrombolysis was followed by systemic heparinization with transition to Coumadin or low molecular-weight heparin and compression stockings. Subjects were followed-up at 1, 3, and then every 6 months after the procedure with clinical assessment and bilateral lower-extremity venous ultrasound. Results: All PCDT procedures were technically successful. No venous stenting or angioplasty was performed. The average thrombolysis time was 28.6 h (range 12-72). Two patients experienced heparin-induced thrombocytopenia, and one patient developed a self-limited knee hemarthrosis, No patients were lost to follow-up. The average length of follow-up was 25.8 {+-} 20.2 months (range 3.8-54.8). No incidence of recurrent DVT was identified. There were no manifestations of postthrombotic syndrome. Conclusions: PCDT followed by systemic anticoagulation and the use of compression stockings appears to be safe and effective in relatively long-term follow-up treatment of patients who present with acute DVT and IVC agenesis or atresia.« less

  2. Thrombus resolution and right ventricular functional recovery using ultrasound-accelerated thrombolysis in acute massive and submassive pulmonary embolism.

    PubMed

    Ozcinar, Evren; Cakici, Mehmet; Dikmen Yaman, Nur; Baran, Cagdas; Aliyev, Anar; Inan, Bahadir; Durdu, Serkan; Akar, Ahmet R; Sirlak, Mustafa

    2017-10-01

    This study aims to evaluate the efficacy and safety of ultrasound-accelerated catheter-directed thrombolysis (UACDT) in the treatment of massive and submassive pulmonary embolism (PE). We conducted a prospective, observational cohort study of consequtive patients with massive or submassive PE treated with low-dose UACDT using EKOS EkoSonic® system at single center from May 2014 until April 2015. Overall, thirty-eight patients (median age, 64.5 years) were included. The primary safety outcomes were change in right ventricular (RV) to left ventricular (LV) diameter ratio within 24 hours of procedure initiation, at 1- and 6-month follow-up and major bleeding within 96 hours of the procedure initiation. BNP, troponin and D-dimer levels were also measured. The ultrasound-accelerated thrombolytic catheters were bilaterally placed in 25 (65.8%) patients. The median tissue plasminogen activator (tPA) dose for all patients in our study was 21.0 mg and the median infusion time was 15 hours. Measurements before and after treatment showed a decrease in pulmonary artery pressure. The median value of RV/LV diameter ratio decreased from 0.9 (0.7-1.1) at baseline to 0.7 (0-0.97) at 6-month follow-up (P=0.001) and pulmonary artery pressure from 61.4 ±16.7 to 37.2±9.1 mmHg (P=0.001). The median BNP level at baseline was 169 (29-721) pg/mL and 45.5 (0-328) pg/mL at 6 month follow-up (P=0.001). Of 38 patients with PE, one had intracranial hemorrage, one gastrointestinal bleeding and two developed puncture site bleeding. This prospective study provides alternative treatment option and an addition to the treatment algorithm for the management of pulmonary embolism.

  3. Ultrasound guided V3 segment vertebral artery direct percutaneous puncture for basilar artery mechanical thrombectomy in acute stroke: a technical report.

    PubMed

    Desai, Jamsheed A; Almekhlafi, Mohammed A; Hill, Michael D; Goyal, Mayank; Eesa, Muneer

    2014-04-01

    A middle aged patient presented with acute ischemic stroke due to basilar artery occlusion. The patient clinically deteriorated despite intravenous thrombolysis and was referred for mechanical thrombectomy. The right vertebral artery was occluded and could not be accessed despite attempting various shaped catheters, even when a radial artery access was used. The left vertebral artery ended in the posterior inferior cerebellar artery. Eventually, ultrasound guided V3 segment vertebral artery direct puncture was successfully done and the procedure was completed. No access related complications were encountered. Direct cervical arterial puncture can be safely used by experienced operators as a last resort in acute stroke cases with difficult access.

  4. Perfusion CT helps decision making for thrombolysis when there is no clear time of onset

    PubMed Central

    Hellier, K D; Hampton, J L; Guadagno, J V; Higgins, N P; Antoun, N M; Day, D J; Gillard, J H; Warburton, E A; Baron, J‐C

    2006-01-01

    Current guidelines on thrombolysis post stroke with recombinant tissue plasminogen activator (rt‐PA) exclude its use where time of onset is unknown, thus denying some patients potentially beneficial treatment. Contrast enhanced perfusion computed tomography (pCT) imaging can be used together with plain CT and information on clinical deficits to decide whether or not thrombolysis should be initiated even though the exact time of stroke onset is unknown. Based on the results of pCT and CT, rt‐PA was administered to two patients with unknown time of stroke onset; one of the patients also underwent suction thrombectomy. Results in both cases were excellent. PMID:16484659

  5. NOR-SASS (Norwegian Sonothrombolysis in Acute Stroke Study): Randomized Controlled Contrast-Enhanced Sonothrombolysis in an Unselected Acute Ischemic Stroke Population.

    PubMed

    Nacu, Aliona; Kvistad, Christopher E; Naess, Halvor; Øygarden, Halvor; Logallo, Nicola; Assmus, Jörg; Waje-Andreassen, Ulrike; Kurz, Kathinka D; Neckelmann, Gesche; Thomassen, Lars

    2017-02-01

    The NOR-SASS (Norwegian Sonothrombolysis in Acute Stroke Study) aimed to assess effect and safety of contrast-enhanced ultrasound treatment in an unselected acute ischemic stroke population. Patients treated with intravenous thrombolysis within 4.5 hours after symptom onset were randomized 1:1 to either contrast-enhanced sonothrombolysis (CEST) or sham CEST. A visible arterial occlusion on baseline computed tomography angiography was not a prerequisite for inclusion. Pulse-wave 2 MHz ultrasound was given for 1 hour and contrast (SonoVue) as an infusion for ≈30 minutes. Magnetic resonance imaging and angiography were performed after 24 to 36 hours. Primary study end points were neurological improvement at 24 hours defined as National Institutes of Health Stroke Scale score 0 or reduction of ≥4 National Institutes of Health Stroke Scale points compared with baseline National Institutes of Health Stroke Scale and favorable functional outcome at 90 days defined as modified Rankin scale score 0 to 1. A total of 183 patients were randomly assigned to either CEST (93 patient) or sham CEST (90 patients). The rates of symptomatic intracerebral hemorrhage, asymptomatic intracerebral hemorrhage, or mortality were not increased in the CEST group. Neurological improvement at 24 hours and functional outcome at 90 days was similar in the 2 groups both in the intention-to-treat analysis and in the per-protocol analysis. CEST is safe among unselected ischemic stroke patients with or without a visible occlusion on computed tomography angiography and with varying grades of clinical severity. There was, however, statistically no significant clinical effect of sonothrombolysis in this prematurely stopped trial. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01949961. © 2016 The Authors.

  6. Targeted thrombolysis by using of magnetic mesoporous silica nanoparticles.

    PubMed

    Wang, Mingqi; Zhang, Jixi; Yuan, Ziming; Yang, Wenzhi; Wu, Qiang; Gu, Hongchen

    2012-08-01

    Thrombolytics inevitably led to the risk of hemorrhagic complications due to their non-specific plasminogen activation in treatment of thrombosis. The aim of this study was to determine whether a kind of superparamagnetic mesoporous silica nanoparticle with expanded pore size could achieve effectively targeted thrombolysis. The magnetic mesoporous silica nanoparticles (M-MSNs) with the pore size of 6 nm were prepared by method of the surfactant templating on nano magnetic particles. We investigated the feasibility and efficacy of target thrombolysis with the resultant spheres through fibrin agarose plate assay (FAPA) and a dynamic flow system in vitro. It displayed a 30-fold enhancement of urokinase (UK) loading capacity over the particles without mesoporous layer or the magnetic spheres with mesopores of 3.7 nm. A sustained release behavior was observed due to its larger pore size, higher surface area and narrow mesopore channals contrast to non-mesoporous and small mesopore of 3.7 nm controls. Meanwhile, fibrin agarose plate assay revealed that UK/M-MSNs exhibited a more rapid growth rate of thrombolysis even lasting for 3 days. Additionally, flow model test in vitro suggested this kind of nanoparticle complex enhanced the thrombolysis efficacy by 3.5 fold over the same amount of native UK in 30 min. When compared to non-mesoporous and small mesopore controls, it also represented an extremely higher lysis efficiency (ANOVA, P < 0.01) and a shorter reperfusion time (ANOVA, P < 0.001). Such a magnetic mesoporous silica nanoparticle carrier was expected to be further studied for targeted thrombolytic therapy.

  7. Evaluation of high resolution ultrasound as a tool for assessing the 3D volume of blood clots during in vitro thrombolysis.

    PubMed

    Auboire, Laurent; Escoffre, Jean-Michel; Fouan, Damien; Jacquet, Jean-René; Ossant, Frédéric; Grégoire, Jean-Marc; Bouakaz, Ayache

    2017-07-24

    Thrombosis is a major cause of several diseases, i.e. myocardial infarction, cerebral stroke and pulmonary embolism. Thrombolytic therapies are required to induce fast and efficient recanalization of occluded vessels. To evaluate the in vitro efficacy of these thrombolytic strategies, measuring clot dissolution is essential. This study aimed to evaluate and validate high resolution ultrasound as a tool to assess the exact volume of clots in 3D and in real time during in vitro thrombolytic drug testing. This new method was validated by measuring the effects of concentration range of recombinant tissue type plasminogen activator on a blood clot during complete occlusion or 70% stenosis of a vessel. This study shows that high resolution ultrasound imaging allows for a real-time assessment of the 3D volume of a blood clot with negligible inter- and intra-operator variabilities. The conclusions drawn from this study demonstrate the promising potential of high resolution ultrasound imaging for the in vitro assessment of new thrombolytic drugs.

  8. Echocardiographic assessment with right ventricular function improvement following ultrasound-accelerated catheter-directed thrombolytic therapy in submassive pulmonary embolism.

    PubMed

    Doheny, Charles; Gonzalez, Lorena; Duchman, Stanley M; Varon, Joseph; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-06-01

    Introduction The objective of this study was to evaluate the efficacy of ultrasound-accelerated catheter-directed thrombolytic therapy in patients with submassive pulmonary embolism. Methods Clinical records of 46 patients with submassive pulmonary embolism who underwent ultrasound-accelerated catheter-directed pulmonary thrombolysis using tissue plasminogen activator, from 2007 to 2017, were analyzed. All patients experienced clinical symptoms with computed tomography evidence of pulmonary thrombus burden. Right ventricular dysfunction was present in all patients by echocardiographic finding of right ventricle-to-left ventricle ratio > 0.9. Treatment outcome, procedural complications, right ventricular pressures, and thrombus clearance were evaluated. Follow-up evaluation included echocardiographic assessment of right ventricle-to-left ventricle ratio at one month, six months, and one year. Results Technical success was achieved in all patients ( n = 46, 100%). Our patients received an average of 18.4 ± 4.7 mg of tissue plasminogen activator using ultrasound-accelerated thrombolytic catheter with an average infusion time of 16.5± 5.4 h. Clinical success was achieved in all patients (100%). Significant reduction of mean pulmonary artery pressure occurred following the treatment, which decreased from 36 ± 8 to 21 ± 5 mmHg ( p < 0.001). There were no major bleeding complications. All-cause mortality at 30 days was 0%. No patient developed recurrent pulmonary embolism during follow-up. During the follow-up period, 43 patients (93%) showed improvement of right ventricular dysfunction based on echocardiographic assessment. The right ventricle-to-left ventricle ratio decreased from 1.32 ± 0.18 to 0.91 ± 0.13 at the time of hospital discharge ( p < 0.01). The right ventricular function remained improved at 6 months and 12 months of follow-up, as right ventricle-to-left ventricle ratio were 0.92 ± 0.14 ( p < 0.01) and 0.91 ± 0.15 ( p < 0.01), respectively. Conclusion Ultrasound-accelerated catheter-directed thrombolysis is a safe and efficacious treatment for submassive pulmonary embolism. It reduces pulmonary hypertension and improves right ventricular function in patients with submassive pulmonary embolism.

  9. Spinal Epidural Hematoma After Thrombolysis for Deep Vein Thrombosis with Subsequent Pulmonary Thromboembolism: A Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Young-Min, E-mail: ymhan@chonbuk.ac.kr; Kwak, Ho-Sung; Jin, Gong-Young

    2006-06-15

    A 38-year-old male was initially admitted for left leg swelling. He was diagnosed as having deep vein thrombosis (DVT) in the left leg and a pulmonary thromboembolism by contrast-enhanced chest computed tomography (CT) with delayed lower extremity CT. The DVT was treated by thrombolysis and a venous stent. Four hours later, he complained of severe back pain and a sensation of separation of his body and lower extremities; he experienced paraplegia early in the morning of the following day. Magnetic resonance imaging showed a spinal epidural hematoma between T11 and L2, which decompressed following surgery. We, therefore, report a casemore » of a spinal epidural hematoma after thrombolysis in a case of DVT with a pulmonary thromboembolism.« less

  10. Ultra-fast bright field and fluorescence imaging of the dynamics of micrometer-sized objects

    NASA Astrophysics Data System (ADS)

    Chen, Xucai; Wang, Jianjun; Versluis, Michel; de Jong, Nico; Villanueva, Flordeliza S.

    2013-06-01

    High speed imaging has application in a wide area of industry and scientific research. In medical research, high speed imaging has the potential to reveal insight into mechanisms of action of various therapeutic interventions. Examples include ultrasound assisted thrombolysis, drug delivery, and gene therapy. Visual observation of the ultrasound, microbubble, and biological cell interaction may help the understanding of the dynamic behavior of microbubbles and may eventually lead to better design of such delivery systems. We present the development of a high speed bright field and fluorescence imaging system that incorporates external mechanical waves such as ultrasound. Through collaborative design and contract manufacturing, a high speed imaging system has been successfully developed at the University of Pittsburgh Medical Center. We named the system "UPMC Cam," to refer to the integrated imaging system that includes the multi-frame camera and its unique software control, the customized modular microscope, the customized laser delivery system, its auxiliary ultrasound generator, and the combined ultrasound and optical imaging chamber for in vitro and in vivo observations. This system is capable of imaging microscopic bright field and fluorescence movies at 25 × 106 frames per second for 128 frames, with a frame size of 920 × 616 pixels. Example images of microbubble under ultrasound are shown to demonstrate the potential application of the system.

  11. Ultra-fast bright field and fluorescence imaging of the dynamics of micrometer-sized objects

    PubMed Central

    Chen, Xucai; Wang, Jianjun; Versluis, Michel; de Jong, Nico; Villanueva, Flordeliza S.

    2013-01-01

    High speed imaging has application in a wide area of industry and scientific research. In medical research, high speed imaging has the potential to reveal insight into mechanisms of action of various therapeutic interventions. Examples include ultrasound assisted thrombolysis, drug delivery, and gene therapy. Visual observation of the ultrasound, microbubble, and biological cell interaction may help the understanding of the dynamic behavior of microbubbles and may eventually lead to better design of such delivery systems. We present the development of a high speed bright field and fluorescence imaging system that incorporates external mechanical waves such as ultrasound. Through collaborative design and contract manufacturing, a high speed imaging system has been successfully developed at the University of Pittsburgh Medical Center. We named the system “UPMC Cam,” to refer to the integrated imaging system that includes the multi-frame camera and its unique software control, the customized modular microscope, the customized laser delivery system, its auxiliary ultrasound generator, and the combined ultrasound and optical imaging chamber for in vitro and in vivo observations. This system is capable of imaging microscopic bright field and fluorescence movies at 25 × 106 frames per second for 128 frames, with a frame size of 920 × 616 pixels. Example images of microbubble under ultrasound are shown to demonstrate the potential application of the system. PMID:23822346

  12. Renal Infarction Caused by Spontaneous Renal Artery Dissection: Treatment with Catheter-Directed Thrombolysis and Stenting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeon, Yong Sun, E-mail: radjeon@korea.com; Cho, Soon Gu; Hong, Ki Cheon

    2009-03-15

    Spontaneous renal artery dissection (SRAD) is rare and presents a diagnostic and therapeutic challenge. We report a case of a 36-year-old man who had an SRAD-complicated renal infarction. The patient experienced severe unilateral flank pain. Enhanced abdominal computed axial tomography scan showed renal infarction, and urinalysis showed no hematuria. Selective renal angiography was essential to evaluate the extent of dissection and suitability for repair. The patient was treated with catheter-directed thrombolysis and frenal artery stenting.

  13. Design of a HIFU array for the treatment of deep venous thrombosis: a simulation study

    NASA Astrophysics Data System (ADS)

    Smirnov, Petr; Hynynen, Kullervo

    2017-08-01

    Deep venous thrombosis of the iliofemoral veins is a common and morbid disease, with the recommended interventional treatment carrying a high risk of hemorrhaging and complications. High intensity focused ultrasound delivered with a single element transducer has been shown to successfully precipitate thrombolysis non-invasively in vitro and in vivo. However, in all previous studies damage to the veins or surrounding tissue has been observed. Using a simulation model of the human thigh, this study investigated whether a phased array device could overcome the large focal region limitations faced by single transducer treatment devices. Effects of the size, shape and frequency of the array on its focal region were considered. It was found that a λ/2 spaced array of 7680 elements operating at 500 kHz could consistently focus to a region fully contained within the femoral vein. Furthermore, it is possible to reduce the number of elements required by building arrays operating at lower frequencies. The results suggest that phased transducer arrays hold potential for developing a safe, non-invasive treatment of thrombolysis.

  14. Imaging of prehospital stroke therapeutics

    PubMed Central

    Lin, Michelle P; Sanossian, Nerses; Liebeskind, David S

    2016-01-01

    Despite significant quality improvement efforts to streamline in-hospital acute stroke care in the conventional model, there remain inherent layers of treatment delays, which could be eliminated with prehospital diagnostics and therapeutics administered in a mobile stroke unit. Early diagnosis using Telestroke and neuroimaging while in the ambulance may enable targeted routing to hospitals with specialized care, which will likely improve patient outcomes. Key clinical trials in Telestroke, mobile stroke units with prehospital neuroimaging capability, prehospital ultrasound and co-administration of various classes of neuroprotectives, antiplatelets and antithrombin agents with intravenous thrombolysis are discussed in this article. PMID:26308602

  15. In vivo Sonothrombolysis of Ear Marginal Vein of Rabbits Monitored with High-frequency Ultrasound Needle Transducer.

    PubMed

    Chen, Ruimin; Paeng, Dong-Guk; Lam, Kwok Ho; Zhou, Qifa; Shung, K Kirk; Matsuoka, Naoki; Humayun, Mark S

    2013-01-01

    Ultrasound (US) is known to enhance thrombolysis when thrombolytic agents and/or microbubbles are injected into the targeted vessels. In this research, high-intensity US (1 MHz, 7 W/cm 2 , 30 % duty cycle) was applied in vivo to the ear marginal vein of three rabbits which was occluded by either laser photothrombosis or thrombin, right after the injection of 0.3~0.6 cc of microbubbles (13 × 10 8 bubbles/ml of concentration) through the other ear vein without using any thrombolytic agent. To determine the effect of the sonothrombolysis, the blood flow velocity near the occlusion site in the vein was measured by a custom-made 40-MHz US needle transducer and its corresponding Doppler US system. The Doppler spectra show that the blood flow velocity recovered from total occlusion after three 10-minute high-intensity US treatments. Fluorescein angiography was employed to confirm the opening of the vessel occlusion. A control study of three rabbits with only the microbubble injection showed no recovery on the occlusion in 3 hours. The results show that the sonothrombolysis in the rabbit ear marginal vein can be achieved with microbubbles only. The results of cavitation measurements indicate that the mechanism of sonothrombolysis is probably due to the cavitation induced by the microbubbles. Without the need of applying any thrombolytic agent, high-intensity US has high potential for therapies targeting on small blood vessels.

  16. The hydrodynamic and ultrasound-induced forces on microbubbles under high Reynolds number flow representative of the human systemic circulation

    NASA Astrophysics Data System (ADS)

    Clark, Alicia; Aliseda, Alberto

    2016-11-01

    Ultrasound contrast agents (UCAs) are micron-sized bubbles that are used in conjunction with ultrasound (US) in medical applications such as thrombolysis and targeted intravenous drug delivery. Previous work has shown that the Bjerknes force, due to the phase difference between the incoming US pressure wave and the bubble volume oscillations, can be used to manipulate the trajectories of microbubbles. Our work explores the behavior of microbubbles in medium sized blood vessels under both uniform and pulsatile flows at a range of physiologically relevant Reynolds and Womersley numbers. High speed images were taken of the microbubbles in an in-vitro flow loop that replicates physiological flow conditions. During the imaging, the microbubbles were insonified at different diagnostic ultrasound settings (varying center frequency, PRF, etc.). An in-house Lagrangian particle tracking code was then used to determine the trajectories of the microbubbles and, thus, a dynamic model for the microbubbles including the Bjerknes forces acting on them, as well as drag, lift, and added mass. Preliminary work has also explored the behavior of the microbubbles in a patient-specific model of a carotid artery bifurcation to demonstrate the feasibility of preferential steering of microbubbles towards the intracranial circulation with US.

  17. Interactions between individual ultrasound-stimulated microbubbles and fibrin clots.

    PubMed

    Acconcia, Christopher; Leung, Ben Y C; Manjunath, Anoop; Goertz, David E

    2014-09-01

    The use of ultrasound-stimulated microbubbles (USMBs) to promote thrombolysis is well established, but there remains considerable uncertainty about the mechanisms of this process. Here we examine the microscale interactions between individual USMBs and fibrin clots as a function of bubble size, exposure conditions and clot type. Microbubbles (n = 185) were placed adjacent to clot boundaries ("coarse" or "fine") using optical tweezers and exposed to 1-MHz ultrasound as a function of pressure (0.1-0.39 MPa). High-speed (10 kfps) imaging was employed, and clots were subsequently assessed with 2-photon microscopy. For fine clots, 46% of bubbles "embedded" within 10 μm of the clot boundary at pressures of 0.1 and 0.2 MPa, whereas at 0.39 MPa, 53% of bubbles penetrated and transited into the clots with an incidence inversely related to their diameter. A substantial fraction of penetrating bubbles induced fibrin network damage and promoted the uptake of nanobeads. In coarse clots, penetration occurred more readily and at lower pressures than in fine clots. The results therefore provide direct evidence of therapeutically relevant effects of USMBs and indicate their dependence on size, exposure conditions and clot properties. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Influence of Renal Impairment on Outcome for Thrombolysis-Treated Acute Ischemic Stroke: ENCHANTED (Enhanced Control of Hypertension and Thrombolysis Stroke Study) Post Hoc Analysis.

    PubMed

    Carr, Susan J; Wang, Xia; Olavarria, Veronica V; Lavados, Pablo M; Rodriguez, Jorge A; Kim, Jong S; Lee, Tsong-Hai; Lindley, Richard I; Pontes-Neto, Octavio M; Ricci, Stefano; Sato, Shoichiro; Sharma, Vijay K; Woodward, Mark; Chalmers, John; Anderson, Craig S; Robinson, Thompson G

    2017-09-01

    Renal dysfunction (RD) is associated with poor prognosis after stroke. We assessed the effects of RD on outcomes and interaction with low- versus standard-dose alteplase in a post hoc subgroup analysis of the ENCHANTED (Enhanced Control of Hypertension and Thrombolysis Stroke Study). A total of 3220 thrombolysis-eligible patients with acute ischemic stroke (mean age, 66.5 years; 37.8% women) were randomly assigned to low-dose (0.6 mg/kg) or standard-dose (0.9 mg/kg) intravenous alteplase within 4.5 hours of symptom onset. Six hundred and fifty-nine (19.8%) patients had moderate-to-severe RD (estimated glomerular filtration rate, <60 mL/min per 1.73 m 2 ) at baseline. The impact of RD on death or disability (modified Rankin Scale scores, 2-6) at 90 days, and symptomatic intracerebral hemorrhage, was assessed in logistic regression models. Compared with patients with normal renal function (>90 mL/min per 1.73 m 2 ), those with severe RD (<30 mL/min per 1.73 m 2 ) had increased mortality (adjusted odds ratio, 2.07; 95% confidence interval, 0.89-4.82; P =0.04 for trend); every 10 mL/min per 1.73 m 2 lower estimated glomerular filtration rate was associated with an adjusted 9% increased odds of death from thrombolysis-treated acute ischemic stroke. There was no significant association with modified Rankin Scale scores 2 to 6 (adjusted odds ratio, 1.03; 95% confidence interval, 0.62-1.70; P =0.81 for trend), modified Rankin Scale 3 to 6 (adjusted odds ratio, 1.20; 95% confidence interval, 0.72-2.01; P =0.44 for trend), or symptomatic intracerebral hemorrhage, or any heterogeneity in comparative treatment effects between low-dose and standard-dose alteplase by RD grades. RD is associated with increased mortality but not disability or symptomatic intracerebral hemorrhage in thrombolysis-eligible and treated acute ischemic stroke patients. Uncertainty persists as to whether low-dose alteplase confers benefits over standard-dose alteplase in acute ischemic stroke patients with RD. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01422616. © 2017 American Heart Association, Inc.

  19. Statistical analysis plan for evaluating low- vs. standard-dose alteplase in the ENhanced Control of Hypertension and Thrombolysis strokE stuDy (ENCHANTED).

    PubMed

    Anderson, Craig S; Woodward, Mark; Arima, Hisatomi; Chen, Xiaoying; Lindley, Richard I; Wang, Xia; Chalmers, John

    2015-12-01

    The ENhanced Control of Hypertension And Thrombolysis strokE stuDy trial is a 2 × 2 quasi-factorial active-comparison, prospective, randomized, open, blinded endpoint clinical trial that is evaluating in thrombolysis-eligible acute ischemic stroke patients whether: (1) low-dose (0·6 mg/kg body weight) intravenous alteplase has noninferior efficacy and lower risk of symptomatic intracerebral hemorrhage compared with standard-dose (0·9 mg/kg body weight) intravenous alteplase; and (2) early intensive blood pressure lowering (systolic target 130-140 mmHg) has superior efficacy and lower risk of any intracerebral hemorrhage compared with guideline-recommended blood pressure control (systolic target <180 mmHg). To outline in detail the predetermined statistical analysis plan for the 'alteplase dose arm' of the study. All data collected by participating researchers will be reviewed and formally assessed. Information pertaining to the baseline characteristics of patients, their process of care, and the delivery of treatments will be classified, and for each item, appropriate descriptive statistical analyses are planned with appropriate comparisons made between randomized groups. For the trial outcomes, the most appropriate statistical comparisons to be made between groups are planned and described. A statistical analysis plan was developed for the results of the alteplase dose arm of the study that is transparent, available to the public, verifiable, and predetermined before completion of data collection. We have developed a predetermined statistical analysis plan for the ENhanced Control of Hypertension And Thrombolysis strokE stuDy alteplase dose arm which is to be followed to avoid analysis bias arising from prior knowledge of the study findings. © 2015 The Authors. International Journal of Stroke published by John Wiley & Sons Ltd on behalf of World Stroke Organization.

  20. Reducing call-to-needle times: the critical role of pre-hospital thrombolysis.

    PubMed

    Smith, J A L; Jennings, K P; Anderson, E A; Green, P; Hillis, G S

    2004-10-01

    Current guidelines recommend that patients with acute myocardial infarction should receive thrombolysis within 60 min of seeking professional help. To compare current rates of pre-hospital thrombolysis in Grampian with historical data, and assess the effect of pre-hospital thrombolysis on the proportion of patients achieving 'call-to-needle' times within national guidelines. Prospective audit. Data were collected on all patients (n=535) admitted to the coronary care unit and thrombolysed, either in hospital or in the community from July 2000 to June 2002, using standardized forms. One hundred and thirty-three patients (25%) received pre-hospital thrombolysis and 402 (75%) received in-hospital thrombolysis. This compares with a 19% (195/1046) pre-hospital thrombolysis rate in the mid-1990s (p=0.005). Median 'call-to-needle' times were 45 min for pre-hospital thrombolysis and 105 min for patients who received in-hospital thrombolysis (p < 0.001). Only 24% (96/396) of patients receiving in-hospital thrombolysis were treated within the recommended guideline, vs. 79% (88/111) of pre-hospital thrombolysis patients (p <0.001). Pre-hospital thrombolysis rates in Grampian are increasing. Administration of thrombolysis in the community greatly increases the proportion of patients achieving a 'call-to-needle' time of 60 min, with a median time saving of approximately 1 h.

  1. A systematic review of ultrasound-accelerated catheter-directed thrombolysis in the treatment of deep vein thrombosis.

    PubMed

    Shi, Yadong; Shi, Wanyin; Chen, Liang; Gu, Jianping

    2018-04-01

    To review the clinical evidence for ultrasound-accelerated catheter-directed thrombolysis (UACDT) using the EKOS system in the treatment of deep vein thrombosis (DVT) in terms of case selection, procedural outcomes, clinical outcomes and safety outcomes. A systematic literature search strategy was used to identify the use of the EKOS system in the treatment of DVT using the following electronic databases: MEDLINE, EMBASE, the Cochrane databases and the Web of Science. The references in the relevant literature were also screened. Our literature search identified a total of 16 unique clinical studies. Twelve of the sixteen studies were retrospective case series studies. To date, only one randomised controlled trial (RCT) is available. Overall, UACDT using the EKOS system was performed 548 times in 512 patients. Among all cases, 77-100% achieved substantial lysis (> 50%) based on the different definitions of the individual studies. This treatment modality appears to be safe, as there were no reported procedure-related pulmonary embolisms (PE) and only one procedure-related death was reported. Bleeding events were reported in 14 of the 16 studies, and 3.9% (20/512) of the cases of bleeding were considered major. During the follow-up, post-thrombotic syndrome was observed in 17.1% (20/117) of cases. UACDT using the EKOS system is an effective, safe and promising treatment modality for DVT, but the existing clinical evidence is inadequate to make UACDT using the EKOS system the first-line choice for DVT. Additional prospective large-sample RCTs with long-term follow-ups are warranted to define the role of UACDT using the EKOS system in the treatment of DVT.

  2. Mechanisms of thrombolysis acceleration by cavitation

    NASA Astrophysics Data System (ADS)

    Weiss, Hope; Selvaraj, Prashanth; Ahadi, Golnaz; Voie, Arne; Hoelscher, Thilo; Okita, Kohei; Matsumoto, Yoichiro; Szeri, Andrew

    2012-11-01

    Recent studies, in vitro and in vivo, have shown that High Intensity Focused Ultrasound (HIFU) accelerates thrombolysis, the dissolution of blood clots, for ischemic stroke. Although the mechanisms are not fully understood, cavitation is thought to play an important role in sonothrombolysis. The damage to a blood clot's fibrin fiber network from cavitation in a HIFU field is studied using two independent approaches for an embedded bubble. One method is extended to the more important scenario of a bubble outside a blood clot that collapses asymmetrically creating a jet towards the clot. There is significantly more damage potential from a bubble undergoing cavitation collapse outside the clot compared to a rapidly expanding bubble embedded within the clot structure. Also, the effects of the physical properties of skull bone when a HIFU wave propagates through it are examined by use of computer simulation. The dynamics of a test bubble placed at the focus is used in understanding of the pressure field. All other things being equal, the analysis suggests that skull thickness can alter the wave at the focus, which in turn can change the nature of cavitation bubble dynamics and the amount of energy available for clot damage. Now at MSOE.

  3. Analysis of stroke care resources in Spain in 2012: have we benefitted from the Spanish Health System's stroke care strategy?

    PubMed

    López Fernández, J C; Masjuan Vallejo, J; Arenillas Lara, J; Blanco González, M; Botia Paniagua, E; Casado Naranjo, I; Deyá Arbona, E; Escribano Soriano, B; Freijo Guerrero, M M; Fuentes, B; Gállego Cullere, J; Geffners Sclarskyi, D; Gil Núñez, A; Gómez Escalonilla, C; Lago Martin, A; Legarda Ramírez, I; Maciñeiras Montero, J L; Maestre Moreno, J; Moniche Álvarez, F; Muñoz Arrondo, R; Purroy García, F; Ramírez Moreno, J M; Rebollo Álvarez Amandix, M; Roquer, J; Rubio Borrego, F; Segura, T; Serrano Ponza, M; Tejada García, J; Tejero Juste, C; Vidal Sánchez, J A

    2014-09-01

    The Spanish Health System's stroke care strategy (EISNS) is a consensus statement that was drawn up by various government bodies and scientific societies with the aim of improving quality throughout the care process and ensuring equality among regions. Our objective is to analyse existing healthcare resources and establish whether they have met EISNS targets. The survey on available resources was conducted by a committee of neurologists representing each of Spain's regions; the same committee also conducted the survey of 2008. The items included were the number of stroke units (SU), their resources (monitoring, neurologists on call 24h/7d, nurse ratio, protocols), SU bed ratio/100,000 inhabitants, diagnostic resources (cardiac and cerebral arterial ultrasound, advanced neuroimaging), performing iv thrombolysis, neurovascular interventional radiology (neuro VIR), surgery for malignant middle cerebral artery (MCA) infarctions and telemedicine availability. We included data from 136 hospitals and found 45 Stroke Units distributed unequally among regions. The ratio of SU beds to residents ranged from 1/74,000 to 1/1,037,000 inhabitants; only the regions of Cantabria and Navarre met the target. Neurologists performed 3,237 intravenous thrombolysis procedures in 83 hospitals; thrombolysis procedures compared to the total of ischaemic strokes yielded percentages ranging from 0.3 to 33.7%. Hospitals without SUs showed varying levels of available resources. Neuro VIR is performed in every region except La Rioja, and VIR is only available on a 24h/7 d basis in 17 cities. Surgery for malignant MCA infarction is performed in 46 hospitals, and 5 have telemedicine. Stroke care has improved in terms of numbers of participating hospitals, the increased use of intravenous thrombolysis and endovascular procedures, and surgery for malignant MCA infarction. Implementation of SUs and telemedicine remain insufficient. The availability of diagnostic resources is good in most SUs and irregular in other hospitals. Regional governments should strive to ensure better care and territorial equality, which would achieve the EISNS objectives. Copyright © 2013 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  4. How is stroke thrombolysis portrayed in UK national and London local newspapers? A review and critical discourse analysis.

    PubMed

    Cluckie, Gillian; Rudd, Anthony G; McKevitt, Christopher

    2012-05-01

    thrombolysis for stroke has been licensed in the UK since 2007 and needs to be administered within 4.5 h. Given this time critical factor, the media may have an important role in public awareness. this review aimed to find out how stroke thrombolysis was reported in UK national and London local newspapers and how treatment risks and benefits were communicated. Newspapers published between 1 January 2007 and 31 March 2010 were searched for articles on thrombolysis. Fifty-six articles were included and dispositive analysis, a qualitative analysis method, was used to identify themes. four main themes were identified: inaccurate description of thrombolysis, stroke clinicians' involvement, presentation of risks and benefits and patient stories. Inaccuracies included the presentation of thrombolysis as a treatment for transient ischaemic attack. Clinicians were quoted to suggest that thrombolysis produced complete recovery but were not reported to discuss risks or broader stroke management. The articles reported little or no risks of treatment. Patients' stories were used to reinforce that thrombolysis produces full recovery. this review found that newspaper media provides the public with inaccurate perspectives on thrombolysis. Clinicians may wish to check press articles prior to publishing and to consider the impact of reporting thrombolysis as a treatment which produces complete recovery.

  5. Safety and functional outcome of thrombolysis in dissection-related ischemic stroke: a meta-analysis of individual patient data.

    PubMed

    Zinkstok, Sanne M; Vergouwen, Mervyn D I; Engelter, Stefan T; Lyrer, Philippe A; Bonati, Leo H; Arnold, Marcel; Mattle, Heinrich P; Fischer, Urs; Sarikaya, Hakan; Baumgartner, Ralf W; Georgiadis, Dimitrios; Odier, Céline; Michel, Patrik; Putaala, Jukka; Griebe, Martin; Wahlgren, Nils; Ahmed, Niaz; van Geloven, Nan; de Haan, Rob J; Nederkoorn, Paul J

    2011-09-01

    The safety and efficacy of thrombolysis in cervical artery dissection (CAD) are controversial. The aim of this meta-analysis was to pool all individual patient data and provide a valid estimate of safety and outcome of thrombolysis in CAD. We performed a systematic literature search on intravenous and intra-arterial thrombolysis in CAD. We calculated the rates of pooled symptomatic intracranial hemorrhage and mortality and indirectly compared them with matched controls from the Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register. We applied multivariate regression models to identify predictors of excellent (modified Rankin Scale=0 to 1) and favorable (modified Rankin Scale=0 to 2) outcome. We obtained individual patient data of 180 patients from 14 retrospective series and 22 case reports. Patients were predominantly female (68%), with a mean±SD age of 46±11 years. Most patients presented with severe stroke (median National Institutes of Health Stroke Scale score=16). Treatment was intravenous thrombolysis in 67% and intra-arterial thrombolysis in 33%. Median follow-up was 3 months. The pooled symptomatic intracranial hemorrhage rate was 3.1% (95% CI, 1.3 to 7.2). Overall mortality was 8.1% (95% CI, 4.9 to 13.2), and 41.0% (95% CI, 31.4 to 51.4) had an excellent outcome. Stroke severity was a strong predictor of outcome. Overlapping confidence intervals of end points indicated no relevant differences with matched controls from the Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register. Safety and outcome of thrombolysis in patients with CAD-related stroke appear similar to those for stroke from all causes. Based on our findings, thrombolysis should not be withheld in patients with CAD.

  6. Choices Regarding Thrombolysis Are Modified by the Way to Transfer the Messages.

    PubMed

    Gong, Jingjing; Zhang, Yan; Gao, Hongyan; Wei, Wei; Lv, Jing; Liu, Hongyun; Huang, Yonghua

    2017-01-01

    Although thrombolysis is the most effective medical treatment for acute ischemic stroke, many stroke patients eligible for thrombolysis miss this treatment as a result of delay or refusal by the patients and/or their proxies. To explore the influences of prognostic information for different intervals from stroke onset to the start of thrombolytic treatment (OTT) and other factors on the preferences of patients/proxies regarding thrombolytic therapy, a cross-sectional, discrete-choice experiment was performed between August 2013 and September 2014. A total of 613 Chinese inpatients or their immediate family members were consecutively recruited at the Department of Neurology. After random assignment to a negative-framing group or a positive-framing group, the subjects completed a series of surveys, including nine items about thrombolysis. Latent class analysis (LCA) was used to examine participants' preference paradigms for thrombolysis and to categorize the participants into different subgroups. Subsequently, regression analyses were conducted to explore predictors of categorization of the participants into each subgroup and to construct a thrombolytic decision-making model. LCA revealed an optimal 3-subgroup model including a consent to thrombolysis subgroup and objection to thrombolysis subgroups 1 and 2. Multiple regression analysis demonstrated that compared with assignment to the consent to thrombolysis subgroup, assignment to objection to thrombolysis subgroup 1 or 2 could be predicted by different factors. χ 2 tests indicated effects of framing and other factors on participants' choices regarding thrombolysis. Choices regarding thrombolysis were modified by not only prognostic information for different OTT intervals but also message framing, presentation format, and sociodemographic characteristics. To facilitate consent to thrombolysis, physicians should convey prognostic information to patients/proxies on the basis of patient OTT interval and should order the presentation of therapies according to the classification of patients/proxies. Individualized decision-making (IDM) might be an optimal strategy to increase the selection of thrombolysis, which providing important reference points for IDM in other clinical domains.

  7. Choices Regarding Thrombolysis Are Modified by the Way to Transfer the Messages

    PubMed Central

    Gong, Jingjing; Zhang, Yan; Gao, Hongyan; Wei, Wei; Lv, Jing; Liu, Hongyun; Huang, Yonghua

    2017-01-01

    Although thrombolysis is the most effective medical treatment for acute ischemic stroke, many stroke patients eligible for thrombolysis miss this treatment as a result of delay or refusal by the patients and/or their proxies. To explore the influences of prognostic information for different intervals from stroke onset to the start of thrombolytic treatment (OTT) and other factors on the preferences of patients/proxies regarding thrombolytic therapy, a cross-sectional, discrete-choice experiment was performed between August 2013 and September 2014. A total of 613 Chinese inpatients or their immediate family members were consecutively recruited at the Department of Neurology. After random assignment to a negative-framing group or a positive-framing group, the subjects completed a series of surveys, including nine items about thrombolysis. Latent class analysis (LCA) was used to examine participants’ preference paradigms for thrombolysis and to categorize the participants into different subgroups. Subsequently, regression analyses were conducted to explore predictors of categorization of the participants into each subgroup and to construct a thrombolytic decision-making model. LCA revealed an optimal 3-subgroup model including a consent to thrombolysis subgroup and objection to thrombolysis subgroups 1 and 2. Multiple regression analysis demonstrated that compared with assignment to the consent to thrombolysis subgroup, assignment to objection to thrombolysis subgroup 1 or 2 could be predicted by different factors. χ2 tests indicated effects of framing and other factors on participants’ choices regarding thrombolysis. Choices regarding thrombolysis were modified by not only prognostic information for different OTT intervals but also message framing, presentation format, and sociodemographic characteristics. To facilitate consent to thrombolysis, physicians should convey prognostic information to patients/proxies on the basis of patient OTT interval and should order the presentation of therapies according to the classification of patients/proxies. Individualized decision-making (IDM) might be an optimal strategy to increase the selection of thrombolysis, which providing important reference points for IDM in other clinical domains. PMID:29167657

  8. How best to obtain consent to thrombolysis: Individualized decision-making.

    PubMed

    Gong, Jingjing; Zhang, Yan; Feng, Jun; Zhang, Weiwei; Yin, Weimin; Wu, Xinhuai; Hou, Yanhong; Huang, Yonghua; Liu, Hongyun; Miao, Danmin

    2016-03-15

    To investigate the factors that influence the preferences of patients and their proxies concerning thrombolytic therapy and to determine how best to convey information. A total of 613 participants were randomly assigned to a positively or negatively framed group. Each participant completed a series of surveys. We applied latent class analysis (LCA) to explore participants' patterns of choices of thrombolysis and to classify the participants into different subgroups. Then we performed regression analyses to investigate predictors of classification of the participants into each subgroup and to establish a thrombolytic decision-making model. LCA indicated an optimal 3-subgroup model comprising intermediate, favorable to thrombolysis, and aversion to thrombolysis subgroups. Multiple regression analysis revealed that 10 factors predicted assignment to the intermediate subgroup and 4 factors predicted assignment to the aversion to thrombolysis subgroup compared with the favorable to thrombolysis subgroup. The χ(2) tests indicated that the information presentation format and the context of thrombolysis influenced participants' choices of thrombolysis and revealed a framing effect in different subgroups. The preference for thrombolysis was influenced by the positive vs negative framing scenarios, the format of item presentation, the context of thrombolysis, and individual characteristics. Inconsistent results may be due to participant heterogeneity and the evaluation of limited factors in previous studies. Based on a decision model of thrombolysis, physicians should consider the effects of positive vs negative framing and should seek a neutral tone when presenting the facts, providing an important reference point for health persuasion in other clinical domains. © 2016 American Academy of Neurology.

  9. Endovascular Thrombolysis Using Monteplase for Non-chronic Deep Venous Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Yoshimatsu, Rika, E-mail: rika442@koto.kpu-m.ac.jp; Tanaka, Osamu, E-mail: otanaka@koto.kpu-m.ac.jp

    This study was designed to evaluate the usefulness of endovascular thrombolysis using monteplase for deep venous thrombosis (DVT). Between December 2005 and October 2009, at our institution nine endovascular thrombolysis treatments with monteplase were performed for symptomatic DVT in eight patients (6 women, 2 men; mean age, 56 (range, 15-80) years). In all, systemic anticoagulation administered by the peripheral intravenous route with heparin and/or thrombolysis with urokinase followed by anticoagulation with orally administered warfarin had been performed, and subsequently six endovascular treatments without monteplase were administered. However, DVT persisted, and endovascular treatments with monteplase were tried. In six (67%) ofmore » the nine procedures, DVT completely or almost completely disappeared after endovascular thrombolysis with monteplase. Mean dose of monteplase used was 2,170,000 IU. There was only one procedure-related complication. In one patient, just after thrombolysis with monteplase, bleeding at the puncture site and gingival bleeding occurred. Bleeding was stopped by manual astriction only. Endovascular thrombolysis with monteplase may be an effective treatment for DVT, even in cases resistant to traditional systemic anticoagulation and thrombolysis and endovascular procedures without monteplase.« less

  10. Relationship of Early Spontaneous Type V Blood Pressure Fluctuation after Thrombolysis in Acute Cerebral Infarction Patients and the Prognosis

    PubMed Central

    Zuo, Lian; Wan, Ting; Xu, Xiahong; Liu, Feifeng; Li, Changsong; Li, Ying; Zhang, Yue; Zhang, Jing; Bao, Huan; Li, Gang

    2016-01-01

    We examined the relationship between an early spontaneous type V blood pressure fluctuation and the post-thrombolysis prognosis of patients with acute cerebral infarction. Patients were admitted consecutively. All patients were categorized into the type V blood pressure fluctuation group or non-type V blood pressure group. Their blood pressure was monitored before thrombolysis and until 6 h after thrombolysis. Baseline data and clinical outcomes were compared. Of 170 patients, 43 (25.2%) had an early type V blood pressure fluctuation. The National Institute of Health Stroke Scale (NIHSS) score before thrombolysis and 24 h after thrombolysis, and the modified Rankin scale score at 90 days differed significantly between the two groups (P < 0.05). Multiple logistic regression analysis showed that an unfavorable prognosis at 3 months was associated with the NIHSS score before thrombolysis (P = 0.000) but probably not with this blood pressure fluctuation (P = 0.058). An early spontaneous type V blood pressure fluctuation is common in patients with acute cerebral infarction who received venous thrombolysis, especially if they have a higher NIHSS score before thrombolysis. The type V blood pressure fluctuation may not influence patients’ prognosis; however, this needs to be confirmed in future trials. PMID:27278121

  11. [Understanding the reasons behind the low utilization of thrombolysis in hyperacute ischemic stroke].

    PubMed

    Zhang, Xiaoxue; Zhang, Jingfen; Li, Ruiming; Cheng, Guojuan; Chen, Qiang

    2016-03-22

    The study aimed to analyze the influencing factors of thrombolysis therapy in acute ischemic stroke patients with onset time less than 4.5 hours. We consecutively prospectively screened acute ischemic stroke patients with onset time less than 4.5 hours from emergency department, outpatients and inpatients of neurology department, and image center in our hospital over a 31-month time period (April 2012-November 2014). The rate of thrombolysis and the reasons for not receiving thrombolysis were analyzed. A total of 538 patients who met the inclusion criteria were included (68.2% males, mean age 67±13 years old). Only 104 (19.3%) patients received thrombolysis. The main reasons for the patients not receiving thrombolysis included minor symptoms (172 cases, 39.6%), rapidly improving symptoms and high possibility of transient ischemic attack (TIA) (59 cases, 13.6%), patients or families refusing thrombolysis (44, 10.1%), in-hospital delay (38, 8.8%), elderly people with age over than 80 years old (38, 8.8%). The thrombolysis rate within time window of acute ischemic stroke is remarkably higher than that of several years ago in China. The main reasons for not receiving thrombolysis are minor and rapidly improving symptoms, patients or families' refusal, in-hospital delay, elderly people with age over than 80 years old.

  12. Dimerized plasmin fragment D as a potential biomarker to predict successful catheter-directed thrombolysis therapy in acute deep vein thrombosis.

    PubMed

    Luo, Chien-Ming; Wu, I-Hui; Chan, Chih-Yang; Chen, Yih-Sharng; Yang, Wei-Shiung; Wang, Shoei-Shen

    2015-10-01

    The value of dimerized plasmin fragment D in the clinical monitoring during the catheter-directed thrombolysis in patients with acute deep vein thrombosis is not known. Dimerized plasmin fragment D levels in 24 patients with acute deep vein thrombosis undergoing catheter-directed thrombolysis were prospectively evaluated. The plasma dimerized plasmin fragment D level was measured serially before and at every 12 h during catheter-directed thrombolysis for 24 h. Technical success was defined as restoration of patency and flow with less than 50% residual thrombus by surveillance rotational venography. Technical success was achieved in 79.2% (19 of 24) of the treated limbs after catheter-directed thrombolysis. In univariate analysis, there was significant elevation of the dimerized plasmin fragment D at 12th h after starting the catheter-directed thrombolysis (P < 0.05) in patients with less than 50% residual thrombus stenosis. The optimal cut-off value of dimerized plasmin fragment D to predict successful catheter-directed thrombolysis was determined as 18.4 µg/ml at the 12th h after starting the catheter-directed thrombolysis with sensitivity 0.8 and specificity 0.8 (P = 0.03). It was further validated in multivariate logistic regression analysis (odds ratio: 14.38; 95% CI: 1.22-169.20; P = 0.03). Catheter-directed thrombolysis is safe and effective for restoration of blood flow in patients with acute deep vein thrombosis. Dimerized plasmin fragment D value greater than 18.4 µg/ml at the 12th h after starting catheter-directed thrombolysis had a high predictive rate of greater than 50% lysis at the end of catheter-directed thrombolysis. © The Author(s) 2014.

  13. Is it beneficial to increase the provision of thrombolysis?-- a discrete-event simulation model.

    PubMed

    Barton, M; McClean, S; Gillespie, J; Garg, L; Wilson, D; Fullerton, K

    2012-07-01

    Although Thrombolysis has been licensed in the UK since 2003, it is still administered only to a small percentage of eligible patients. We consider the impact of investing the impact of thrombolysis on important acute stroke services, and the effect on quality of life. The concept is illustrated using data from the Northern Ireland Stroke Service. Retrospective study. We first present results of survival analysis utilizing length of stay (LOS) for discharge destinations, based on data from the Belfast City Hospital (BCH). None of these patients actually received thrombolysis but from those who would have been eligible, we created two initial groups, the first representing a scenario where they received thrombolysis and the second comprising those who do not receive thrombolysis. On the basis of the survival analysis, we created several subgroups based on discharge destination. We then developed a discrete event simulation (DES) model, where each group is a patient pathway within the simulation. Coxian phase type distributions were used to model the group LOS. Various scenarios were explored focusing on cost-effectiveness across hospital, community and social services had thrombolysis been administered to these patients, and the possible improvement in quality of life, should the proportion of patients who are administered thrombolysis be increased. Our aim in simulating various scenarios for this historical group of patients is to assess what the cost-effectiveness of thrombolysis would have been under different scenarios; from this we can infer the likely cost-effectiveness of future policies. The cost of thrombolysis is offset by reduction in hospital, community rehabilitation and institutional care costs, with a corresponding improvement in quality of life. Our model suggests that provision of thrombolysis would produce moderate overall improvement to the service assuming current levels of funding.

  14. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    PubMed

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Is there still a place for emergency department thrombolysis following the introduction of the amended Joint Royal Colleges Ambulance Liaison Committee criteria for thrombolysis?

    PubMed

    Castle, N R; Owen, R C; Hann, M

    2007-12-01

    To apply the current (2004) and the amended (2006) Joint Royal Colleges Ambulance Liaison Committee (JRCALC) criteria for paramedic initiated thrombolysis to all patients who received thrombolytic treatment in an emergency department (ED) to determine if the amendments increase the proportion suitable for paramedic initiated thrombolysis. Retrospective descriptive analysis. The ED clinical notes, ambulance clinical record and the first recorded ECG (ED or ambulance) of all patients thrombolysed in the ED during a 12 month period were reviewed against the previous JRCALC guidelines (2004) and the amended JRCALC guidelines (2006) for thrombolysis. Using the JRCALC guidelines (2004), 26 of the 147 patients (17.7%) were eligible for paramedic initiated thrombolysis. Using the JRCALC guidelines (2006), this increased to 41 (27.9%). This difference was statistically significant (McNemar's I2 test with 1 degree of freedom = 15.00; p<0.001). The change to the blood pressure, age and pulse rate parameters has increased the percentage eligible for paramedic initiated thrombolysis by 10.2% (95% confidence interval 4.6% to 15.8%). The amended JRCALC guidelines (2006) for paramedic initiated thrombolysis have successfully increased the proportion of patients suitable for prehospital thrombolysis by approximately 10%, although the ED retains an important role in the provision of prompt thrombolytic treatment for a proportion of patients.

  16. The Chinese Stroke Association scientific statement: intravenous thrombolysis in acute ischaemic stroke

    PubMed Central

    Dong, Qiang; Dong, Yi; Liu, Liping; Xu, Anding; Zhang, Yusheng; Zheng, Huaguang; Wang, Yongjun

    2017-01-01

    The most effective medical treatment for acute ischaemic stroke (AIS) is to offer intravenous thrombolysis during the ultra-early period of time after the onset. Even based on the Consensus of Chinese Experts on Intravenous Thrombolysis for AIS in 2012 and 2014 Chinese Guidelines on the Diagnosis and Treatment of AIS, the rate of thrombolysis for AIS in China remained around 2.4%, and the rate of intravenous tissue plasminogen activator usage was only about 1.6% in real world. The indication of thrombolysis for AIS has been expanded, and contraindications have been reduced with recently published studies. In order to facilitate the standardisation of treating AIS, improve the rate of thrombolysis and benefit patients who had a stroke, Chinese Stroke Association has organised and developed this scientific statement. PMID:28989804

  17. Reasons and evolution of non-thrombolysis in acute ischaemic stroke

    PubMed Central

    Reiff, T; Michel, P

    2017-01-01

    Introduction Despite increasing evidence of its efficacy in advanced age or in mild or severe strokes, intravenous thrombolysis remains underused for acute ischaemic stroke (AIS). Our aim was to obtain an updated view of reasons for non-thrombolysis and to identify its changing patterns over time. Methods This is a retrospective study of prospectively collected data from the Acute Stroke Registry and Analysis of Lausanne (ASTRAL) from the years 2003–2011. Patients admitted with acute stroke in the past 24 hours who had not had thrombolysis were identified; reasons for non-thrombolysis documented in the prospectively entered data were tabulated and analysed for the group as a whole. Data were analysed for the years 2003–2006 and 2007 forward because of changes in contraindications. A subgroup of patients who arrived within the treatment window ≤180 min was separately analysed for reasons for non-thrombolysis. Predictors of non-thrombolysis were investigated via multivariate regression analyses. Results In the 2019 non-thrombolysed patients the most frequent reasons for non-thrombolysis were admission delays (66.3%), stroke severity (mostly mild) (47.9%) and advanced age (14.1%); 55.9% had more than one exclusion criterion. Among patients arriving ≤180 min after onset, the main reasons were stroke severity and advanced age. After 2006, significantly fewer patients were excluded because of age (OR 2.65, p<0.001) or (mostly mild) stroke severity (OR 10.56, p=0.029). Retrospectively, 18.7% of all non-thrombolysed patients could have been treated because they only had relative contraindications. Conclusion Onset-to-admission delays remain the main exclusion criterion for thrombolysis. Among early arrivals, relative contraindications such as minor stroke severity and advanced age were frequent. Thrombolysis rate increased with the reduction of thrombolysis restrictions (eg, age and stroke severity). PMID:27797870

  18. Mid-term outcome of endovascular treatment for acute lower extremity deep venous thrombosis.

    PubMed

    Jiang, Kun; Li, Xiao-Qiang; Sang, Hong-Fei; Qian, Ai-Min; Rong, Jian-Jie; Li, Cheng-Long

    2017-04-01

    Purposes of the study To evaluate the benefit of stenting the iliac vein in patients with residual iliac vein stenosis treated with catheter-directed thrombolysis for acute iliofemoral deep venous thrombosis. Procedures In this randomized prospective study, patients with a first-time acute lower extremity deep venous thrombosis that had persisted <14 days were treated with catheter-directed thrombolysis. After catheter-directed thrombolysis, patients with >50% residual iliac vein stenosis were randomly divided into two groups: catheter-directed thrombolysis + Stent Group and catheter-directed thrombolysis Alone Group. Patients received urokinase thrombolysis and low-molecular-weight heparin/oral warfarin during the hospitalization period and were administrated oral warfarin after discharge. Cumulative deep vein patency, the Clinical Etiology Anatomic Pathophysiologic classification system, the Venous Clinical Severity Score and the Chronic Venous Insufficiency Questionnaire score were evaluated. Findings The cumulative deep vein patency rate was 74.07% in the catheter-directed thrombolysis + Stent Group and 46.59% in the catheter-directed thrombolysis Alone Group. The mean postoperative Clinical Etiology Anatomic Pathophysiologic classification and Venous Clinical Severity Score was significantly lower in the catheter-directed thrombolysis + Stent Group than in the catheter-directed thrombolysis Alone Group. The mean postoperative Chronic Venous Insufficiency Questionnaire score was significantly higher in the catheter-directed thrombolysis + Stent Group than the catheter-directed thrombolysis Alone Group. Conclusions Placement of an iliac vein stent in patients with residual iliac vein stenosis after catheter-directed thrombolysis for acute lower extremity deep venous thrombosis increases iliac vein patency and improves clinical symptoms and health-related quality of life at mid-term follow-up compared to patients treated with catheter-directed thrombolysis alone.

  19. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder.

    PubMed

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-11-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound for inter-reader agreements were 0.717, 0.794 and 0.914. Three-dimensional contrast-enhanced ultrasound imaging, with contrast-enhanced spatial visualization is clinical useful for differentiating invasive and noninvasive neoplasms of urinary bladder objectively. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. TREATMENT OF MICROVASCULAR MICRO-EMBOLIZATION USING MICROBUBBLES AND LONG-TONE-BURST ULTRASOUND: AN IN VIVO STUDY

    PubMed Central

    Pacella, John J.; Brands, Judith; Schnatz, Frederick G.; Black, John J.; Chen, Xucai; Villanueva, Flordeliza S.

    2015-01-01

    Despite epicardial coronary artery reperfusion by percutaneous coronary intervention, distal micro-embolization into the coronary microcirculation limits myocardial salvage during acute myocardial infarction. Thrombolysis using ultrasound and microbubbles (sonothrombolysis) is an approach that induces microbubble oscillations to cause clot disruption and restore perfusion. We sought to determine whether this technique could restore impaired tissue perfusion caused by thrombotic microvascular obstruction. In 16 rats, an imaging transducer was placed on the biceps femoris muscle, perpendicular to a single-element 1-MHz treatment transducer. Ultrasound contrast perfusion imaging was performed at baseline and after micro-embolization. Therapeutic ultrasound (5000 cycles, pulse repetition frequency = 5 0.33 Hz, 1.5 MPa) was delivered to nine rats for two 10-min sessions during intra-arterial infusion of lipid-encapsulated microbubbles; seven control rats received no ultrasound–microbubble therapy. Ultrasound contrast perfusion imaging was repeated after each treatment or control period, and microvascular volume was measured as peak video intensity. There was a 90% decrease in video intensity after micro-embolization (from 8.6 ± 4.8 to 0.7 ± 0.8 dB, p < 0.01). The first and second ultrasound–microbubble sessions were respectively followed by video intensity increases of 5.8 ± 5.1 and 8.7 ± 5.7 dB (p < 0.01, compared with micro-embolization). The first and second control sessions, respectively, resulted in no significant increase in video intensity (2.4 ± 2.3 and 3.6 ± 4.9) compared with micro-embolization (0.6 ± 0.7 dB). We have developed an in vivo model that simulates the distal thrombotic microvascular obstruction that occurs after primary percutaneous coronary intervention. Long-pulse-length ultrasound with microbubbles has a therapeutic effect on microvascular perfusion and may be a valuable adjunct to reperfusion therapy for acute myocardial infarction. PMID:25542487

  1. Catheter-Directed Thrombolysis via Small Saphenous Veins for Treating Acute Deep Venous Thrombosis.

    PubMed

    Yang, Bin; Xu, Xiao-Dong; Gao, Peng; Yu, Ji-Xiang; Li, Yu; Zhu, Ai-Dong; Meng, Ran-Ran

    2016-08-23

    BACKGROUND There is little data comparing catheter-directed thrombolysis (CDT) via small saphenous veins vs. systematic thrombolysis on complications and efficacy in acute deep venous thrombosis patients. The aim of our study was to compare the efficacy and safety of CDT via the small saphenous veins with systematic thrombolysis for patients with acute deep venous thrombosis (DVT). MATERIAL AND METHODS Sixty-six patients with acute DVT admitted from June 2012 to December 2013 were divided into 2 groups: 27 patients received systemic thrombolysis (ST group) and 39 patients received CDT via the small saphenous veins (CDT group). The thrombolysis efficiency, limb circumference differences, and complications such as post-thrombotic syndrome (PTS) in the 2 groups were recorded. RESULTS The angiograms demonstrated that all or part of the fresh thrombus was dissolved. There was a significant difference regarding thrombolysis efficiency between the CDT group and ST group (71.26% vs. 48.26%, P=0.001). In both groups the postoperative limb circumference changes were higher compared to the preoperative values. The differences between postoperative limb circumferences on postoperative days 7 and 14 were significantly higher in the CDT group than in the ST group (all P<0.05). The incidence of postoperative PTS in the CDT group (17.9%) was significantly lower in comparison to the ST group (51.85%) during the follow-up (P=0.007). CONCLUSIONS Catheter-directed thrombolysis via the small saphenous veins is an effective, safe, and feasible approach for treating acute deep venous thrombosis.

  2. Ultrasound-enhanced localized chemotherapy of drug-sensitive and multidrug resistant tumors

    NASA Astrophysics Data System (ADS)

    Rapoport, Natalya Y.; Gao, Zhonggao; Kamaev, Pavel; Christensen, Douglas A.

    2006-05-01

    A new modality of targeted tumor chemotherapy is based on the drug encapsulation in polymeric nanoparticles followed by a localized release at the tumor site triggered by focused ultrasound. Effect of 1 MHz and 3 MHz unfocused ultrasound applied locally to the tumor on the Doxorubicin (DOX) biodistribution and tumor growth rates was measured for ovarian carcinoma tumors in nu/nu mice. The bioeffects of ultrasound were investigated on the systemic and cellular levels. Growth rates of A2780 ovarian carcinoma tumors were substantially reduced by combining micellar drug delivery with tumor irradiation. Ultrasound effect was not thermal as manifested by intratumoral temperature measurements during sonication. Biodistribution studies showed that ultrasound did not enhance micelle extravasation. Main mechanisms of the ultrasound-enhanced chemotherapy included (i) passive targeting of drug-loaded micelles to the tumor interstitium; (ii) ultrasound-triggered localized drug release from micelles in the tumor volume; (iii) enhanced micelle and drug diffusion through the tumor interstitium; and (iv) ultrasound-triggered cell membrane damage resulting in the enhanced micelle and drug uptake by tumor cells.

  3. Acute deep vein thrombosis and endovascular techniques: It is time for a new aggiornamento!

    PubMed

    Pernès, J-M; Auguste, M; Kovarski, S; Borie, H; Renaudin, J-M; Coppe, G

    2012-10-01

    The stated aims of treating acute deep vein thrombosis (DVT) are to prevent a pulmonary embolism, stop the clot from spreading, reduce the risk of a recurrence; they are less concerned with the late morbidity associated with post-thrombotic syndrome (PTS). In accordance with the French (Afssaps, 2009) and North American (ACCP, 2008) recommendations, anticoagulants (LMWH, heparin, AVK) form the cornerstone for treating DVT. These treatments appear to be far less effective in preventing post-thrombotic syndrome (PTS), associated with venous hypertension, residual occlusion, and with reflux caused by valve incompetence. Given that, the new aim is to optimise the prevention of PTS, the ACCP guidelines, unlike those of Afssaps, "suggest" for selected patients suffering from acute iliofemoral DVT, the use of both classic anticoagulants, and in situ percutaneous administration of thrombolytic drugs (recommendation grade 2B) and simultaneous correction of any underlying anatomical anomalies using angioplasty and stenting (recommendation 2C). Contemporary endovascular methods, referred to collectively as "facilitated" thrombolysis, combine low doses of rtPa or Urokinase administered locally, and the removal of the clot using various mechanical, rotating, rheolytic systems, or using ultrasound. The results of non-randomised, heterogeneous studies objectivised a lysis rate of 80%, a 50% lower risk of haemorrhage complications compared with systemic thrombolysis (<4%), and a clear reduction in treatment time (one-shot methods possible for procedures lasting less than 2 hours). This data ties in with the modern "open vein" concept which underpins the hope of an improvement in the late prognosis of acute DVT, through the removal of a clot, thereby improving permeability and valve integrity; this hypothesis is supported by the results at 24 months of a randomised CaVent objectifying absolute risk reduction of 15% in the thrombolysis in situ. The current randomised study (ATTRACT trial) comparing the combination of "facilitated thrombolysis" in addition to the usual treatment with the traditional treatment alone for acute iliofemoral DVT, the statistical power of which has been established (600 patients) to authenticate a reduction by a third in the number of PTS (CaVent trial, showing a 15% reduction rate of 24 months PTS in the thrombolysed group results expected in 2016), might, if the results are positive, lead to a profound change in the paradigms for the treatment of acute iliofemoral DVT. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  4. Pharmacomechanical Catheter-Directed Thrombolysis for Deep-Vein Thrombosis.

    PubMed

    Vedantham, Suresh; Goldhaber, Samuel Z; Julian, Jim A; Kahn, Susan R; Jaff, Michael R; Cohen, David J; Magnuson, Elizabeth; Razavi, Mahmood K; Comerota, Anthony J; Gornik, Heather L; Murphy, Timothy P; Lewis, Lawrence; Duncan, James R; Nieters, Patricia; Derfler, Mary C; Filion, Marc; Gu, Chu-Shu; Kee, Stephen; Schneider, Joseph; Saad, Nael; Blinder, Morey; Moll, Stephan; Sacks, David; Lin, Judith; Rundback, John; Garcia, Mark; Razdan, Rahul; VanderWoude, Eric; Marques, Vasco; Kearon, Clive

    2017-12-07

    The post-thrombotic syndrome frequently develops in patients with proximal deep-vein thrombosis despite treatment with anticoagulant therapy. Pharmacomechanical catheter-directed thrombolysis (hereafter "pharmacomechanical thrombolysis") rapidly removes thrombus and is hypothesized to reduce the risk of the post-thrombotic syndrome. We randomly assigned 692 patients with acute proximal deep-vein thrombosis to receive either anticoagulation alone (control group) or anticoagulation plus pharmacomechanical thrombolysis (catheter-mediated or device-mediated intrathrombus delivery of recombinant tissue plasminogen activator and thrombus aspiration or maceration, with or without stenting). The primary outcome was development of the post-thrombotic syndrome between 6 and 24 months of follow-up. Between 6 and 24 months, there was no significant between-group difference in the percentage of patients with the post-thrombotic syndrome (47% in the pharmacomechanical-thrombolysis group and 48% in the control group; risk ratio, 0.96; 95% confidence interval [CI], 0.82 to 1.11; P=0.56). Pharmacomechanical thrombolysis led to more major bleeding events within 10 days (1.7% vs. 0.3% of patients, P=0.049), but no significant difference in recurrent venous thromboembolism was seen over the 24-month follow-up period (12% in the pharmacomechanical-thrombolysis group and 8% in the control group, P=0.09). Moderate-to-severe post-thrombotic syndrome occurred in 18% of patients in the pharmacomechanical-thrombolysis group versus 24% of those in the control group (risk ratio, 0.73; 95% CI, 0.54 to 0.98; P=0.04). Severity scores for the post-thrombotic syndrome were lower in the pharmacomechanical-thrombolysis group than in the control group at 6, 12, 18, and 24 months of follow-up (P<0.01 for the comparison of the Villalta scores at each time point), but the improvement in quality of life from baseline to 24 months did not differ significantly between the treatment groups. Among patients with acute proximal deep-vein thrombosis, the addition of pharmacomechanical catheter-directed thrombolysis to anticoagulation did not result in a lower risk of the post-thrombotic syndrome but did result in a higher risk of major bleeding. (Funded by the National Heart, Lung, and Blood Institute and others; ATTRACT ClinicalTrials.gov number, NCT00790335 .).

  5. Risks of atrial fibrillation and death at discharge after thrombolysis in stroke patients: Northumbrian Sentinel Stroke Audit, 2013-2015.

    PubMed

    Shiue, I

    2017-02-01

    The aim of this study was to examine risks of atrial fibrillation and death at discharge in stroke patients treated with thrombolysis in a subregional setting covering full calendar years with a clear study catchment drawn serving as a confirmatory statistical analysis from the northeast of England in the last 2 years. Data between 16 June, 2013 and 15 June, 2015 were extracted from Sentinel Stroke National Audit Programme in Northumbria Healthcare NHS Foundation Trust that has covered health service for Northumberland and North Tyneside. The very old people aged 80 and above were less likely to have thrombolysis treatment, while there was no sex difference observed. Moreover, thrombolysis treatment was more likely to be given in ischemic patients with severe stroke symptoms. There was no difference in comorbidities including atrial fibrillation, congestive heart failure, diabetes, hypertension, and stroke/TIA as well. Those who received thrombolysis treatment were more likely to have atrial fibrillation or die at discharge. The ORs were higher after additionally adjusting for comorbidities. Similarly, these patients also had poorer scoring in modified Rankin scale than those who did not receive thrombolysis treatment. However, there was no difference at 6 months after survival. For future research, clinical outcomes in addition to atrial fibrillation and quality of life both at discharge and 6 months after thrombolysis treatment should be included for examination as well. For clinical practice, giving thrombolysis treatment in hospitals might need to be reconsidered if clinical outcomes were actually worse than not. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Real-time 3-dimensional contrast-enhanced ultrasound in detecting hemorrhage of blunt renal trauma.

    PubMed

    Xu, Rui-Xue; Li, Ye-Kuo; Li, Ting; Wang, Sha-Sha; Yuan, Gui-Zhong; Zhou, Qun-Fang; Zheng, Hai-Rong; Yan, Fei

    2013-10-01

    The objective of this study is to evaluate the diagnostic value of real-time 3-dimensional contrast-enhanced ultrasound in the hemorrhage of blunt renal trauma. Eighteen healthy New Zealand white rabbits were randomly divided into 3 groups. Blunt renal trauma was performed on each group by using minitype striker. Ultrasonography, color Doppler flow imaging, and contrast-enhanced 2-dimensional and real-time 3-dimensional ultrasound were applied before and after the strike. The time to shock and blood pressure were subjected to statistical analysis. Then, a comparative study of ultrasound and pathology was carried out. All the struck kidneys were traumatic. In the ultrasonography, free fluid was found under the renal capsule. In the color Doppler flow imaging, active hemorrhage was not identified. In 2-dimensional contrast-enhanced ultrasound, active hemorrhage of the damaged kidney was characterized. Real-time 3-dimensional contrast-enhanced ultrasound showed a real-time and stereoscopic ongoing bleeding of the injured kidney. The wider the hemorrhage area in 4-dimensional contrast-enhanced ultrasound was, the faster the blood pressure decreased. Real-time 3-dimensional contrast-enhanced ultrasound is a promising noninvasive tool for stereoscopically and vividly detecting ongoing hemorrhage of blunt renal trauma in real time. © 2013.

  7. Different Imaging Strategies in Patients With Possible Basilar Artery Occlusion: Cost-Effectiveness Analysis.

    PubMed

    Beyer, Sebastian E; Hunink, Myriam G; Schöberl, Florian; von Baumgarten, Louisa; Petersen, Steffen E; Dichgans, Martin; Janssen, Hendrik; Ertl-Wagner, Birgit; Reiser, Maximilian F; Sommer, Wieland H

    2015-07-01

    This study evaluated the cost-effectiveness of different noninvasive imaging strategies in patients with possible basilar artery occlusion. A Markov decision analytic model was used to evaluate long-term outcomes resulting from strategies using computed tomographic angiography (CTA), magnetic resonance imaging, nonenhanced CT, or duplex ultrasound with intravenous (IV) thrombolysis being administered after positive findings. The analysis was performed from the societal perspective based on US recommendations. Input parameters were derived from the literature. Costs were obtained from United States costing sources and published literature. Outcomes were lifetime costs, quality-adjusted life-years (QALYs), incremental cost-effectiveness ratios, and net monetary benefits, with a willingness-to-pay threshold of $80,000 per QALY. The strategy with the highest net monetary benefit was considered the most cost-effective. Extensive deterministic and probabilistic sensitivity analyses were performed to explore the effect of varying parameter values. In the reference case analysis, CTA dominated all other imaging strategies. CTA yielded 0.02 QALYs more than magnetic resonance imaging and 0.04 QALYs more than duplex ultrasound followed by CTA. At a willingness-to-pay threshold of $80,000 per QALY, CTA yielded the highest net monetary benefits. The probability that CTA is cost-effective was 96% at a willingness-to-pay threshold of $80,000/QALY. Sensitivity analyses showed that duplex ultrasound was cost-effective only for a prior probability of ≤0.02 and that these results were only minimally influenced by duplex ultrasound sensitivity and specificity. Nonenhanced CT and magnetic resonance imaging never became the most cost-effective strategy. Our results suggest that CTA in patients with possible basilar artery occlusion is cost-effective. © 2015 The Authors.

  8. Different Imaging Strategies in Patients With Possible Basilar Artery Occlusion

    PubMed Central

    Beyer, Sebastian E.; Hunink, Myriam G.; Schöberl, Florian; von Baumgarten, Louisa; Petersen, Steffen E.; Dichgans, Martin; Janssen, Hendrik; Ertl-Wagner, Birgit; Reiser, Maximilian F.

    2015-01-01

    Background and Purpose— This study evaluated the cost-effectiveness of different noninvasive imaging strategies in patients with possible basilar artery occlusion. Methods— A Markov decision analytic model was used to evaluate long-term outcomes resulting from strategies using computed tomographic angiography (CTA), magnetic resonance imaging, nonenhanced CT, or duplex ultrasound with intravenous (IV) thrombolysis being administered after positive findings. The analysis was performed from the societal perspective based on US recommendations. Input parameters were derived from the literature. Costs were obtained from United States costing sources and published literature. Outcomes were lifetime costs, quality-adjusted life-years (QALYs), incremental cost-effectiveness ratios, and net monetary benefits, with a willingness-to-pay threshold of $80 000 per QALY. The strategy with the highest net monetary benefit was considered the most cost-effective. Extensive deterministic and probabilistic sensitivity analyses were performed to explore the effect of varying parameter values. Results— In the reference case analysis, CTA dominated all other imaging strategies. CTA yielded 0.02 QALYs more than magnetic resonance imaging and 0.04 QALYs more than duplex ultrasound followed by CTA. At a willingness-to-pay threshold of $80 000 per QALY, CTA yielded the highest net monetary benefits. The probability that CTA is cost-effective was 96% at a willingness-to-pay threshold of $80 000/QALY. Sensitivity analyses showed that duplex ultrasound was cost-effective only for a prior probability of ≤0.02 and that these results were only minimally influenced by duplex ultrasound sensitivity and specificity. Nonenhanced CT and magnetic resonance imaging never became the most cost-effective strategy. Conclusions— Our results suggest that CTA in patients with possible basilar artery occlusion is cost-effective. PMID:26022634

  9. Off-label thrombolysis versus full adherence to the current European Alteplase license: impact on early clinical outcomes after acute ischemic stroke.

    PubMed

    Cappellari, Manuel; Moretto, Giuseppe; Micheletti, Nicola; Donato, Francesco; Tomelleri, Giampaolo; Gulli, Giosuè; Carletti, Monica; Squintani, Giovanna Maddalena; Zanoni, Tiziano; Ottaviani, Sarah; Romito, Silvia; Tommasi, Giorgio; Musso, Anna Maria; Deotto, Luciano; Gambina, Giuseppe; Zimatore, Domenico Sergio; Bovi, Paolo

    2014-05-01

    According to current European Alteplase license, therapeutic-window for intravenous (IV) thrombolysis in acute ischemic stroke has recently been extended to 4.5 h after symptoms onset. However, due to numerous contraindications, the portion of patients eligible for treatment still remains limited. Early neurological status after thrombolysis could identify more faithfully the impact of off-label Alteplase use that long-term functional outcome. We aimed to identify the impact of off-label thrombolysis and each off-label criterion on early clinical outcomes compared with the current European Alteplase license. We conducted an analysis on prospectively collected data of 500 consecutive thrombolysed patients. The primary outcome measures included major neurological improvement (NIHSS score decrease of ≤8 points from baseline or NIHSS score of 0) and neurological deterioration (NIHSS score increase of ≥4 points from baseline or death) at 24 h. We estimated the independent effect of off-label thrombolysis and each off-label criterion by calculating the odds ratio (OR) with 2-sided 95% confidence interval (CI) for each outcome measure. As the reference, we used patients fully adhering to the current European Alteplase license. 237 (47.4%) patients were treated with IV thrombolysis beyond the current European Alteplase license. We did not find significant differences between off- and on-label thrombolysis on early clinical outcomes. No off-label criteria were associated with decreased rate of major neurological improvement compared with on-label thrombolysis. History of stroke and concomitant diabetes was the only off-label criterion associated with increased rate of neurological deterioration (OR 5.84, 95% CI 1.61-21.19; p = 0.024). Off-label thrombolysis may be less effective at 24 h than on-label Alteplase use in patients with previous stroke and concomitant diabetes. Instead, the impact of other off-label criteria on early clinical outcomes was not different compared with current European Alteplase license.

  10. Thrombolysis research--new objectives after a shift of accent.

    PubMed

    Maksimenko, Alexander V

    2002-01-01

    The methods of increasing the efficacy of thrombolysis under clinical and experimental conditions are have been discussed in the light of analysis of current tendencies in the investigation and development of thrombolytic and adjunctive therapy. Analysis of the data obtained in the search for novel plasminogen activators for thrombolytic enzyme therapy has shown a decrease and depletion of this search. The reserves for further increase in thrombolysis efficiency have been notified. Special attention is paid to the purposes, realms and problems of adjunctive therapy, which is a promising breakthrough area in the effort of increasing the efficacy of thrombolysis.

  11. Protective effects of angiopoietin-like 4 on the blood-brain barrier in acute ischemic stroke treated with thrombolysis in mice.

    PubMed

    Zhang, Bin; Xu, Xiaofeng; Chu, Xiuli; Yu, Xiaoyang; Zhao, Yuwu

    2017-04-03

    Given the risk of blood-brain barrier damage (BBB) caused by ischemic and tissue plasminogen activator thrombolysis, the preservation of vascular integrity is important. Angiopoietin-like 4 (ANGPTL4), a protein secreted in hypoxia, is involved in the regulation of vascular permeability. We hypothesized that Angptl4 might exert a protective effect in thrombolysis through stabilizing blood-brain barrier and inhibit hyper-permeability. We investigated the role of Angptl4 in stroke using a transient focal cerebral ischemia mouse model. The treated mice were administered Angptl4 1h after the ischemic event upon reperfusion. Our results showed that Angptl4 combined with thrombolysis greatly reduced the infarct volume and consequent neurological deficit. Western blot analyses and gelatin zymography revealed that Angptl4 protected the integrity of the endothelium damaged by thrombolysis. Angptl4 inhibited the up-regulation of vascular endothelial growth factor (VEGF) in the vascular endothelium after stroke, which was suppressed by counteracting VEGFR signaling and diminishing downstream Src signaling, and led to the increased stability of junctions and improved endothelial cell barrier integrity. These findings demonstrated that Angptl4 protects the permeability of the BBB damaged by ischemic and thrombolysis. Suggested that Angptl4 might be a promising target molecule in therapies for vasoprotection after thrombolysis treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Model for Porosity Changes Occurring during Ultrasound-Enhanced Transcorneal Drug Delivery.

    PubMed

    Hariharan, Prasanna; Nabili, Marjan; Guan, Allan; Zderic, Vesna; Myers, Matthew

    2017-06-01

    Ultrasound-enhanced drug delivery through the cornea has considerable therapeutic potential. However, our understanding of how ultrasound enhances drug transport is poor, as is our ability to predict the increased level of transport for given ultrasound parameters. Described here is a computational model for quantifying changes in corneal porosity during ultrasound exposure. The model is calibrated through experiments involving sodium fluorescein transport through rabbit cornea. Validation was performed using nylon filters, for which the properties are known. It was found that exposure to 800-kHz ultrasound at an intensity 2 W/cm 2 for 5 min increased the porosity of the epithelium by a factor of 5. The model can be useful for determining the extent to which ultrasound enhances the amount of drug transported through biological barriers, and the time at which a therapeutic dose is achieved at a given location, for different drugs and exposure strategies. Published by Elsevier Inc.

  13. National use of thrombolysis with alteplase for acute ischaemic stroke via telemedicine in Denmark: a model of budgetary impact and cost effectiveness.

    PubMed

    Ehlers, Lars; Müskens, Wilhelmina Maria; Jensen, Lotte Groth; Kjølby, Mette; Andersen, Grethe

    2008-01-01

    The purpose of this analysis was to assess the budgetary impact and cost effectiveness of the national use of thrombolysis with alteplase (recombinant tissue plasminogen activator; rt-PA) for acute ischaemic stroke via telemedicine in Denmark. Computations were based on a Danish health economic model of thrombolysis treatment of acute ischaemic stroke via telemedicine. Cost data for stroke units and satellite clinics were taken from the first practical experiences in Denmark with implementing thrombolysis via telemedical linkage to the Stroke Department at Aarhus University Hospital. Effectiveness data were taken from a published pooled analysis of results from randomized controlled trials of alteplase. The calculations showed that the additional total costs to the hospitals of implementing thrombolysis with alteplase for acute ischaemic stroke via telemedicine were approximately $US3.0 (range 2.0-5.8) million per year in the case of five centres and five satellite clinics, or $US3.6 (range 2.4-7.0) million per year based on seven centres and seven satellite clinics. The incremental cost-effectiveness ratio was calculated to be approximately $US50,000 when taking a short time perspective (1 year), but thrombolysis was dominant (both cheaper and more effective) after as little as 2 years and cost effectiveness improved over longer time scales. The budgetary impact of using thrombolysis with alteplase for acute ischaemic stroke via telemedicine depends on the existing capacity and organizational conditions at the local hospitals. The health economic model computations suggest that the macroeconomic costs may balance with savings in care and rehabilitation after as little as 2 years, and that potentially large long-term savings are associated with thrombolysis with alteplase delivered by telemedicine, although the long-term calculations are uncertain.

  14. The t-PA-encapsulated PLGA nanoparticles shelled with CS or CS-GRGD alter both permeation through and dissolving patterns of blood clots compared with t-PA solution: an in vitro thrombolysis study.

    PubMed

    Wang, Shoei-Shen; Chou, Nai-Kuan; Chung, Tze-Wen

    2009-12-01

    Accelerated thrombolysis by pressure-driven permeation has been demonstrated in in vitro and in vivo animal models by using plasminogen activators (PAs) encapsulated liposomes or PEG microparticles. Recent reports have also described acceleration of thrombolysis using tissue type PA (t-PA) encapsulated in PLGA nanoparticles (NPs) coated with chitosan (CS) or CS-GRGD by interactions between the NPs and blood clots. However, the permeation through and dissolving patterns in thrombolysis with the aforementioned microparticles or NPs, which may be clinically relevant to the recovery status of the posttreatments, have not been reported. Therefore, this work studied such phenomena in thrombolysis with t-PA encapsulated in NPs. The t-PA solution and the NPs exhibited distinctly different permeation patterns of dissolved clots. Plasma permeates through clots showed a stream flow or burst flow phenomena when lyzed with NPs shelled with CS or CS-GRGD, respectively, whereas a diffusion pattern was observed in those lyzed with t-PA solution. At the outlet position of clots, the clots dissolved with PLGA/CS and PLGA/CS-GRGD NPs revealed extremely rough surfaces to a depth of 100 mum, indicating that a cross-permeation direction of clot lysis occurred, while those dissolved with t-PA solution showed slightly rough surfaces to a depth of 12 mum. Permeation through and clot dissolution patterns of thrombolysis with t-PA encapsulated in NPs shelled with CS or CS-GRGD distinctly differed from those dissolved with t-PA solutions in this in vitro thrombolysis model, These findings may be relevant to posttreatment of patients with conventional PA thrombolysis. Copyright 2008 Wiley Periodicals, Inc.

  15. Thrombolysis in Acute Ischemic Stroke: A Simulation Study to Improve Pre- and in-Hospital Delays in Community Hospitals

    PubMed Central

    Lahr, Maarten M. H.; van der Zee, Durk-Jouke; Vroomen, Patrick C. A. J.; Luijckx, Gert-Jan; Buskens, Erik

    2013-01-01

    Background Various studies demonstrate better patient outcome and higher thrombolysis rates achieved by centralized stroke care compared to decentralized care, i.e. community hospitals. It remains largely unclear how to improve thrombolysis rate in decentralized care. The aim of this simulation study was to assess the impact of previously identified success factors in a central model on thrombolysis rates and patient outcome when implemented for a decentral model. Methods Based on a prospectively collected dataset of 1084 ischemic stroke patients, simulation was used to replicate current practice and estimate the effect of re-organizing decentralized stroke care to resemble a centralized model. Factors simulated included symptom onset call to help, emergency medical services transportation, and in-hospital diagnostic workup delays. Primary outcome was proportion of patients treated with thrombolysis; secondary endpoints were good functional outcome at 90 days, Onset-Treatment-Time (OTT), and OTT intervals, respectively. Results Combining all factors might increase thrombolysis rate by 7.9%, of which 6.6% ascribed to pre-hospital and 1.3% to in-hospital factors. Good functional outcome increased by 11.4%, 8.7% ascribed to pre-hospital and 2.7% to in-hospital factors. The OTT decreased 17 minutes, 7 minutes ascribed to pre-hospital and 10 minutes to in-hospital factors. An increase was observed in the proportion thrombolyzed within 1.5 hours; increasing by 14.1%, of which 5.6% ascribed to pre-hospital and 8.5% to in-hospital factors. Conclusions Simulation technique may target opportunities for improving thrombolysis rates in acute stroke. Pre-hospital factors proved to be the most promising for improving thrombolysis rates in an implementation study. PMID:24260151

  16. Audit of thrombolysis initiated in an accident and emergency department.

    PubMed Central

    Nee, P A; Gray, A J; Martin, M A

    1994-01-01

    Early thrombolytic therapy after acute myocardial infarction is important in reducing mortality. To evaluate a system for reducing in-hospital delays to thrombolysis pain to needle and door to needle times to thrombolysis were audited in a major accident and emergency (A and E) department of a district general hospital and its coronary care unit (CCU), situated about 5 km away. Baseline performance over six months was assessed retrospectively from notes of 43 consecutive patients (group 1) transferred to the CCU before receiving thrombolysis. Subsequently, selected patients (23) were allowed to receive thrombolysis in the A and E department before transfer to the CCU. The agent was administered by medical staff in the department after receiving oral confirmation of myocardial infarction from the admitting medical officer in the CCU on receipt of fax transmission of the electrocardiogram. A second prospective audit during six months from the start of the new procedure established time intervals in 23 patients eligible to receive thrombolysis in the A and E department (group 2b) and 30 ineligible patients who received thrombolysis in the CCU (group 2a). The groups did not differ significantly in case mix, pre-hospital delay, or transfer time to the CCU. In group 2b door to needle time and pain to needle time were reduced significantly (geometric mean 38 min v 121 min (group 2a) and 128 min (group 1); 141 min v 237 min (group 2a) and 242 min (group 1) respectively, both p < 0.0001). The incidence of adverse effects was not significantly different. Nine deaths occurred (six in group 1, three in group 2b), an in-hospital mortality of 9.9%. Thrombolysis can be safely instituted in the A and E department in selected patients, significantly reducing delay to treatment. PMID:10136256

  17. Comparison of gadobenate dimeglumine-enhanced breast MRI and gadopentetate dimeglumine-enhanced breast MRI with mammography and ultrasound for the detection of breast cancer.

    PubMed

    Gilbert, Fiona J; van den Bosch, Harrie C M; Petrillo, Antonella; Siegmann, Katja; Heverhagen, Johannes T; Panizza, Pietro; Gehl, Hans-Björn; Pediconi, Federica; Diekmann, Felix; Peng, Wei-Jun; Ma, Lin; Sardanelli, Francesco; Belli, Paolo; Corcione, Stefano; Zechmann, Christian M; Faivre-Pierret, Matthieu; Martincich, Laura

    2014-05-01

    To compare gadobenate dimeglumine-enhanced magnetic resonance imaging (MRI) with gadopentetate dimeglumine-enhanced MRI, mammography, and ultrasound for breast cancer detection across different malignant lesion types and across different densities of breast tissue. In all, 153 women with Breast Imaging Reporting and Data System (BI-RADS) 3–5 findings on mammography and/or ultrasound underwent identical breast MRI exams at 1.5T with gadobenate dimeglumine and gadopentetate dimeglumine. Images were evaluated by three independent blinded radiologists. Mammography, ultrasound, and combined mammography and/or ultrasound findings were available for 108, 109, and 131 women. Imaging findings were matched with histology data by a fourth, independent, blinded radiologist. Malignant lesion detection rates and diagnostic performance were compared. In all, 120, 120, and 140 confirmed malignant lesions were present in patients undergoing MRI+mammography, MRI+ultrasound, and MRI+mammography and/or ultrasound, respectively. Significantly greater cancer detection rates were noted by all three readers for comparisons of gadobenate dimeglumine-enhanced MRI with mammography (Δ15.8–17.5%; P < 0.0001), ultrasound (Δ18.3–20.0%; P < 0.0001), and mammography and/or ultrasound (Δ8.6–10.7%; P ≤ 0.0105) but not for comparisons of gadopentetate dimeglumine-enhanced MRI with conventional techniques (P > 0.05). The false-positive detection rates were lower on gadobenate dimeglumine-enhanced MRI than on conventional imaging (4.0–5.5% vs. 11.1% at mammography; 6.3–8.4% vs. 15.5% at ultrasound). Significantly improved cancer detection on MRI was noted in heterogeneously dense breast (91.2–97.3% on gadobenate dimeglumine-enhanced MRI vs. 77.2–84.9% on gadopentetate dimeglumine-enhanced MRI vs. 71.9-84.9% with conventional techniques) and for invasive cancers (93.2–96.2% for invasive ductal carcinoma [IDC] on gadobenate dimeglumine-enhanced MRI vs. 79.7–88.5% on gadopentetate dimeglumine-enhanced MRI vs. 77.0–84.4% with conventional techniques). Overall diagnostic performance for the detection of cancer was superior on gadobenate dimeglumine-enhanced MRI than on conventional imaging or gadopentetate dimeglumine-enhanced MRI. Gadobenate dimeglumine-enhanced MRI significantly improves cancer detection compared to gadopentetate dimeglumine-enhanced MRI, mammography, and ultrasound in a selected group of patients undergoing breast MRI for preoperative staging or because of inconclusive findings at conventional imaging.

  18. Catheter-Directed Thrombolysis of Acute Deep Vein Thrombosis in the Lower Extremity of a Child with Interrupted Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Ozkan, Ugur; Tercan, Fahri

    2007-04-15

    We present the case of a 14-year-old girl who developed acute deep vein thrombosis (DVT) in her right lower extremity. Laboratory testing revealed protein S deficiency, and the patient's father also had this abnormality with a history of lower extremity DVT. Manual thromboaspiration followed by catheter-directed thrombolysis resulted in total clearance of all thrombi. Computed tomography and later venography revealed an interrupted inferior vena cava. Catheter-directed thrombolysis is an established treatment for adults with acute DVT. To the best of our knowledge, this report is the first to describe catheter-directed thrombolysis in a pediatric patient with lower extremity DVT. Ourmore » results suggest that catheter-directed thrombolysis is safe and effective for use in selected older children and adolescents with acute DVT in the lower extremity.« less

  19. A preliminary evaluation of self-made nanobubble in contrast-enhanced ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Li, Chunfang; Wu, Kaizhi; Li, Jing; Liu, Haijuan; Zhou, Qibing; Ding, Mingyue

    2014-03-01

    Nanoscale bubbles (nanobubbles) have been reported to improve contrast in tumor-targeted ultrasound imaging due to the enhanced permeation and retention effects at tumor vascular leaks. In this work, a self-made nanobubble ultrasound contrast agent was preliminarily characterized and evaluated in-vitro and in-vivo. Fundamental properties such as morphology appearance, size distribution, zeta potential, bubble concentration (bubble numbers per milliliter contrast agent suspension) and the stability of nanobubbles were assessed by light microscope and particle sizing analysis. Then the concentration intensity curve and time intensity curves (TICs) were acquired by ultrasound imaging experiment in-vitro. Finally, the contrast-enhanced ultrasonography was performed on rat to investigate the procedure of liver perfusion. The results showed that the nanobubbles had good shape and uniform distribution with the average diameter of 507.9 nm, polydispersity index (PDI) of 0.527, and zeta potential of -19.17 mV. Significant contrast enhancement was observed in in-vitro ultrasound imaging, demonstrating that the self-made nanobubbles can enhance the contrast effect of ultrasound imaging efficiently in-vitro. Slightly contrast enhancement was observed in in-vivo ultrasound imaging, indicating that the nanobubbles are not stable enough in-vivo. Future work will be focused on improving the ultrasonic imaging performance, stability, and antibody binding of the nanoscale ultrasound contrast agent.

  20. Extensive deep vein thrombosis following prolonged gaming ('gamer's thrombosis'): a case report.

    PubMed

    Chang, Hsien-Cheng Leon; Burbridge, Hayley; Wong, Conroy

    2013-10-08

    The average time spent playing video games is increasing. Prolonged immobility associated with gaming may therefore be an important risk factor for venous thromboembolism. We report a case of deep vein thrombosis associated with prolonged playing of PlayStation® games. A 31-year-old Caucasian man, an exterior painter, presented with a three-day history of left leg pain and swelling after playing PlayStation® games for almost eight hours a day for four consecutive days. Doppler ultrasound of the left leg confirmed extensive left leg deep venous thrombosis requiring thrombolysis and anticoagulation. Video gaming should be considered a risk factor for venous thromboembolism. Further studies are needed to estimate the degree of risk associated with prolonged periods of playing video games, and education for preventing venous thrombosis should be provided to gamers.

  1. [Prehospital thrombolysis during cardiopulmonary resuscitation].

    PubMed

    Spöhr, F; Böttiger, B W

    2005-02-01

    Although prehospital cardiac arrest has an incidence of 40-90/100,000 inhabitants per year, there has been a lack of therapeutic options to improve the outcome of these patients. Of all cardiac arrests, 50-70% are caused by acute myocardial infarction (AMI) or massive pulmonary embolism (PE). Thrombolysis has been shown to be a causal and effective therapy in patients with AMI or PE who do not suffer cardiac arrest. In contrast, experience with the use of thrombolysis during cardiac arrest has been limited. Thrombolysis during cardiopulmonary resuscitation (CPR) acts directly on thrombi or emboli causing AMI or PE. In addition, experimental studies suggest that thrombolysis causes an improvement in microcirculatory reperfusion after cardiac arrest. In-hospital and prehospital case series and clinical studies suggest that thrombolysis during CPR may cause a restoration of spontaneous circulation and survival even in patients that have been resuscitated conventionally without success. In addition, there is evidence for an improved neurological outcome in patients receiving a thrombolytic therapy during during CPR. A large randomized, double-blind multicenter trial that has started recently is expected to show if this new therapeutic option can generally improve the prognosis of patients with cardiac arrest.

  2. Predictors of Thrombolysis Administration in Mild Stroke: Florida-Puerto Rico Collaboration to Reduce Stroke Disparities.

    PubMed

    Asdaghi, Negar; Wang, Kefeng; Ciliberti-Vargas, Maria A; Gutierrez, Carolina Marinovic; Koch, Sebastian; Gardener, Hannah; Dong, Chuanhui; Rose, David Z; Garcia, Enid J; Burgin, W Scott; Zevallos, Juan Carlos; Rundek, Tatjana; Sacco, Ralph L; Romano, Jose G

    2018-03-01

    Mild stroke is the most common cause for thrombolysis exclusion in patients acutely presenting to the hospital. Thrombolysis administration in this subgroup is highly variable among different clinicians and institutions. We aim to study the predictors of thrombolysis in patients with mild ischemic stroke in the FL-PR CReSD registry (Florida-Puerto Rico Collaboration to Reduce Stroke Disparities). Among 73 712 prospectively enrolled patients with a final diagnosis of ischemic stroke or TIA from January 2010 to April 2015, we identified 7746 cases with persistent neurological symptoms and National Institutes of Health Stroke Scale ≤5 who arrived within 4 hours of symptom onset. Multilevel logistic regression analysis with generalized estimating equations was used to identify independent predictors of thrombolytic administration in the subgroup of patients without contraindications to thrombolysis. We included 6826 cases (final diagnosis mild stroke, 74.6% and TIA, 25.4%). Median age was 72 (interquartile range, 21); 52.7% men, 70.3% white, 12.9% black, 16.8% Hispanic; and median National Institutes of Health Stroke Scale, 2 (interquartile range, 3). Patients who received thrombolysis (n=1281, 18.7%) were younger (68 versus 72 years), had less vascular risk factors (hypertension, diabetes mellitus, and dyslipidemia), had lower risk of prior vascular disease (myocardial infarction, peripheral vascular disease, and previous stroke), and had a higher presenting median National Institutes of Health Stroke Scale (4 versus 2). In the multilevel multivariable model, early hospital arrival (arrive by 0-2 hours versus ≥3.5 hours; odds ratio [OR], 8.16; 95% confidence interval [CI], 4.76-13.98), higher National Institutes of Health Stroke Scale (OR, 1.87; 95% CI, 1.77-1.98), aphasia at presentation (OR, 1.35; 95% CI, 1.12-1.62), faster door-to-computed tomography time (OR, 1.81; 95% CI, 1.53-2.15), and presenting to an academic hospital (OR, 2.02; 95% CI, 1.39-2.95) were independent predictors of thrombolysis administration. Mild acutely presenting stroke patients are more likely to receive thrombolysis if they are young, white, or Hispanic and arrive early to the hospital with more severe neurological presentation. Identification of predictors of thrombolysis is important in design of future studies to assess the use of thrombolysis for mild stroke. © 2018 American Heart Association, Inc.

  3. Medical Ultrasound Technology Research and Development at the University of Washington Center for Industrial and Medical Ultrasound

    DTIC Science & Technology

    2003-10-02

    provide a world-class, advanced research center for bioengineering development and graduate education in high-intensity, focused ultrasound ( HIFU ). This...convenient, and robust. These technological enhancements have enabled the development of HIFU arrays and image-guided ultrasound systems for greater... Ultrasound (CIMU). The many disparate facilities and technical capabilities available to CIMU staff and students were integrated and enhanced to

  4. Effects of golden hour thrombolysis: a Prehospital Acute Neurological Treatment and Optimization of Medical Care in Stroke (PHANTOM-S) substudy.

    PubMed

    Ebinger, Martin; Kunz, Alexander; Wendt, Matthias; Rozanski, Michal; Winter, Benjamin; Waldschmidt, Carolin; Weber, Joachim; Villringer, Kersten; Fiebach, Jochen B; Audebert, Heinrich J

    2015-01-01

    The effectiveness of intravenous thrombolysis in acute ischemic stroke is time dependent. The effects are likely to be highest if the time from symptom onset to treatment is within 60 minutes, termed the golden hour. To determine the achievable rate of golden hour thrombolysis in prehospital care and its effect on outcome. The prospective controlled Prehospital Acute Neurological Treatment and Optimization of Medical Care in Stroke study was conducted in Berlin, Germany, within an established infrastructure for stroke care. Weeks were randomized according to the availability of a specialized ambulance (stroke emergency mobile unit (STEMO) from May 1, 2011, through January 31, 2013. We included 6182 consecutive adult patients for whom a stroke dispatch (44.1% male; mean [SD] age, 73.9 [15.0] years) or regular care (45.0% male; mean [SD] age, 74.2 [14.9] years) were included. The STEMO was deployed when the dispatchers suspected an acute stroke during emergency calls. If STEMO was not available (during control weeks, when the unit was already in operation, or during maintenance), patients received conventional care. The STEMO is equipped with a computed tomographic scanner plus a point-of-care laboratory and telemedicine connection. The unit is staffed with a neurologist trained in emergency medicine, a paramedic, and a technician. Thrombolysis was started in STEMO if a stroke was confirmed and no contraindication was found. Rates of golden hour thrombolysis, 7- and 90-day mortality, secondary intracerebral hemorrhage, and discharge home. Thrombolysis rates in ischemic stroke were 200 of 614 patients (32.6%) when STEMO was deployed and 330 of 1497 patients (22.0%) when conventional care was administered (P < .001). Among all patients who received thrombolysis, the proportion of golden hour thrombolysis was 6-fold higher after STEMO deployment (62 of 200 patients [31.0%] vs 16 of 330 [4.9%]; P < .01). Compared with patients with a longer time from symptom onset to treatment, patients who received golden hour thrombolysis had no higher risks for 7- or 90-day mortality (adjusted odds ratios, 0.38 [95% CI, 0.09-1.70]; P = .21 and 0.69 [95% CI, 0.32-1.53]; P = .36) and were more likely to be discharged home (adjusted odds ratio, 1.93 [95% CI, 1.09-3.41]; P = .02). The use of STEMO increases the percentage of patients receiving thrombolysis within the golden hour. Golden hour thrombolysis entails no risk to the patients' safety and is associated with better short-term outcomes. clinicaltrials.gov Identifier: NCT01382862.

  5. Extensive Mobile Thrombus of the Internal Carotid Discovered After Intravenous Thrombolysis

    PubMed Central

    Fugate, Jennifer E.; Hocker, Sara E.

    2016-01-01

    This case report describes a rare presentation of ischemic stroke secondary to an extensive internal carotid artery thrombus, subsequent therapeutic dilemma, and clinical management. A 58-year-old man was administered intravenous (IV) thrombolysis for right middle cerebral artery territory ischemic stroke symptoms. A computed tomography angiogram of the head and neck following thrombolysis showed a longitudinally extensive internal carotid artery thrombus originating at the region of high-grade calcific stenosis. Mechanical embolectomy was deferred because of risk of clot dislodgement and mild neurological symptoms. Recumbency and hemodynamic augmentation were used acutely to support cerebral perfusion. Anticoagulation was started 24 hours after thrombolysis. Carotid endarterectomy was completed successfully within 1 week of presentation. Clinical outcome was satisfactory with discharge modified Rankin Scale score 0. A longitudinally extensive carotid artery thrombus poses a risk of dislodgement and hemispheric stroke. Optimal management in these cases is not known with certainty. In our case, IV thrombolysis, hemodynamic augmentation, delayed anticoagulation, and carotid endarterectomy resulted in a favorable clinical outcome. PMID:28400904

  6. Pharmacomechanical thrombolysis with a rotator thrombolysis device in iliofemoral deep venous thrombosis.

    PubMed

    Karahan, Oguz; Kutas, H Barıs; Gurbuz, Orcun; Tezcan, Orhan; Caliskan, Ahmet; Yavuz, Celal; Demirtas, Sinan; Mavitas, Binali

    2016-10-01

    Deep venous thrombosis (DVT) is a life-threatening and morbid pathology. This study aimed to investigate the efficacy of an early thrombolysis procedure using a rotator thrombolysis device. Sixty-seven patients with acute proximal DVT were enrolled in the study. Patients' data were recorded retrospectively. Initially, an infrarenal retrievable vena cava filter was placed through the femoral vein. Then, a rotator thrombolysis device and a thrombolytic agent injection were applied to the occluded segments of the deep veins by puncturing the popliteal vein. The identified reasons were trauma (43.3%), pregnancy (20.9%), undiagnosed (11.9%), major surgical operation (10.5%), immobilization (7.5%), and malignancy (5.9%). Immediate total recanalization was conducted in all patients, and the leg diameters returned to normal ranges in the early postoperative period. Hospital mortality or severe complications were not detected. New thrombolytic devices seem to reduce in-hospital mortality risks and may potentially decrease post-thrombotic morbidity. © The Author(s) 2015.

  7. Inflammatory response, neutrophil activation, and free radical production after acute myocardial infarction: effect of thrombolytic treatment.

    PubMed Central

    Bell, D; Jackson, M; Nicoll, J J; Millar, A; Dawes, J; Muir, A L

    1990-01-01

    Activated neutrophils releasing proteolytic enzymes and oxygen free radicals have been implicated in extending myocardial injury after myocardial infarction. Neutrophil elastase was used as a marker of neutrophil activation and the non-peroxide diene conjugate of linoleic acid was used as an indicator of free radical activity in 32 patients after acute myocardial infarction; 17 were treated by intravenous thrombolysis. Patients with acute myocardial infarction had higher plasma concentrations of neutrophil elastase and the non-peroxide diene conjugated isomer of linoleic acid than normal volunteers or patients with stable ischaemic heart disease. Patients treated by thrombolysis had an early peak of neutrophil elastase at eight hours while those who had not been treated by thrombolysis showed a later peak 40 hours after infarction. The plasma concentration of non-peroxide conjugated diene of linoleic acid was highest 16 hours after the infarction irrespective of treatment by thrombolysis. Quantitative imaging with single photon emission tomography showed decreased uptake of indium-111 labelled neutrophils in the infarcted myocardium (as judged from technetium-99m pyrophosphate) in those who had received thrombolysis, suggesting a decreased inflammatory response. The results indicate increased neutrophil activation and free radical production after myocardial infarction; they also suggest that thrombolysis does not amplify the inflammatory response and may indeed suppress it. Images PMID:2317413

  8. Mechanical Recanalization following i.v. Thrombolysis: A Retrospective Analysis regarding Secondary Hemorrhagic Infarctions and Parenchymal Hematomas

    PubMed Central

    Höltje, J.; Bonk, F.; Anstadt, A.; Terborg, C.; Pohlmann, C.; Urban, P. P.; Brüning, R.

    2015-01-01

    Introduction. In acute stroke by occlusion of the proximal medial cerebral artery (MCA) or the distal internal carotid artery, intravenous thrombolysis is an established treatment. Another option is mechanical recanalization. It remains unclear if the combination of both methods poses an additional bleeding risk. The aim of this retrospective analysis is to determine the proportion of hemorrhagic infarctions and parenchymal hematomas. Methods. Inclusion criteria were an occlusion of the carotid T or proximal MCA treated with full dose thrombolysis and mechanical recanalization. 31 patients were selected. Devices used were Trevo, Penumbra Aspiration system, Penumbra 3D Retriever, and Revive. The initial control by computed tomography was carried out with a mean delay to intervention of 10.9 hours (SD: 8.5 hours). Results. A slight hemorrhagic infarction (HI1) was observed in 2/31 patients, and a more severe HI2 occurred in two cases. A smaller parenchymal hematoma (PH1) was not seen and a space-occupying PH2 was seen in 2/31 cases. There was no significant difference in the probability of intracranial bleeding after successful (thrombolysis in cerebral infarctions 2b and 3) or unsuccessful recanalization. Conclusion. The proportion of intracranial bleeding using mechanical recanalization following intravenous thrombolysis appears comparable with reports using thrombolysis alone. PMID:26640710

  9. Can online benchmarking increase rates of thrombolysis? Data from the Austrian stroke unit registry.

    PubMed

    Ferrari, Julia; Seyfang, Leonhard; Lang, Wilfried

    2013-09-01

    Despite its widespread availability and known safety and efficacy, a therapy with intravenous thrombolysis is still undergiven. We aimed to identify whether nationwide quality projects--like the stroke registry in Austria--as well as online benchmarking and predefined target values can increase rates of thrombolysis. Therefore, we assessed 6,394 out of 48,462 patients with ischemic stroke from the Austrian stroke registry (study period from March 2003 to December 2011) who had undergone thrombolysis treatment. We defined lower level and target values as quality parameters and evaluated whether or not these parameters could be achieved in the past years. We were able to show that rates of thrombolysis in Austria increased from 4.9% in 2003 to 18.3% in 2011. In a multivariate regression model, the main impact seen was the increase over the years [the OR ranges from 0.47 (95% CI 0.32-0.68) in 2003 to 2.51 (95% CI 2.20-2.87) in 2011). The predefined lower and target levels of thrombolysis were achieved at the majority of participating centers: in 2011 the lower value of 5% was achieved at all stroke units, and the target value of 15% was observed at 21 of 34 stroke units. We conclude that online benchmarking and the concept of defining target values as a tool for nationwide acute stroke care appeared to result in an increase in the rate of thrombolysis over the last few years while the variability between the stroke units has not yet been reduced.

  10. Understanding clinicians’ decisions to offer intravenous thrombolytic treatment to patients with acute ischaemic stroke: a protocol for a discrete choice experiment

    PubMed Central

    De Brún,, Aoife; Flynn, Darren; Joyce, Kerry; Ternent, Laura; Price, Christopher; Rodgers, Helen; Ford, Gary A; Lancsar, Emily; Rudd, Matthew; Thomson, Richard G

    2014-01-01

    Background Intravenous thrombolysis is an effective emergency treatment for acute ischaemic stroke for patients meeting specific criteria. Approximately 12% of eligible patients in England, Wales and Northern Ireland received thrombolysis in the first quarter of 2013, yet as many as 15% are eligible to receive treatment. Suboptimal use of thrombolysis may have been largely attributable to structural factors; however, with the widespread implementation of 24/7 hyper acute stroke services, continuing variation is likely to reflect differences in clinical decision-making, in particular the influence of ambiguous areas within the guidelines, licensing criteria and research evidence. Clinicians’ perceptions about thrombolysis may now exert a greater influence on treatment rates than structural/service factors. This research seeks to elucidate factors influencing thrombolysis decision-making by using patient vignettes to identify (1) patient-related and clinician-related factors that may help to explain variation in treatment and (2) associated trade-offs in decision-making based on the interplay of critical factors. Methods/analysis A discrete choice experiment (DCE) will be conducted to better understand how clinicians make decisions about whether or not to offer thrombolysis to patients with acute ischaemic stroke. To inform the design, exploratory work will be undertaken to ensure that (1) all potentially influential factors are considered for inclusion; and (2) to gain insights into the ‘grey areas’ of patient factors. A fractional factorial design will be used to combine levels of patient factors in vignettes, which will be presented to clinicians to allow estimation of the variable effects on decisions to offer thrombolysis. Ethics and dissemination Ethical approval for this study was obtained from the Newcastle University Research Ethics Committee. The results will be disseminated in peer review publications and at national conferences. Findings will be translated into continuing professional development activities and will support implementation of a computerised decision aid for thrombolysis (COMPASS) in acute stroke care. PMID:25009137

  11. Acute Superior Mesenteric Venous Thrombosis: Transcatheter Thrombolysis and Aspiration Thrombectomy Therapy by Combined Route of Superior Mesenteric Vein and Artery in Eight Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Shuofei, E-mail: yangshuofei@gmail.com; Liu, Baochen, E-mail: 306446264@qq.com; Ding, Weiwei, E-mail: dingwei-nju@hotmail.com

    PurposeTo assess the feasibility, effectiveness, and safety of catheter-directed thrombolysis and aspiration thrombectomy therapy by combined route of superior mesenteric vein and artery (SMV+SMA) for acute superior mesenteric venous thrombosis (ASMVT).MethodsThis retrospective study reviewed eight ASMVT patients with transcatheter direct thrombolysis and aspiration thrombectomy therapy via SMV and indirect thrombolysis via SMA during a period of 14 months. The demographics, etiology, risk factors, therapeutic effect, complications, mortality, and follow-up of the study population were assessed. Anatomic and imaging classification of location and extent of thrombus at diagnosis and degree of thrombus lysis were described.ResultsTechnical success was achieved with substantial improvement inmore » symptoms and thrombus resolution after thrombolytic therapy in all patients. The local urokinase infusion by SMA and SMV was performed for 5–7 (6.13 ± 0.83) and 7–15 (12 ± 2.51) days. Anticoagulation was performed catheter-directed and then orally throughout hospitalization and after discharge. Four patients required delayed localized bowel resection after thrombolytic therapy with no death. Thrombolytic therapy was not interrupted despite minor bleeding at the puncture site in two patients and sepsis in another two postoperatively. Nearly complete removal of thrombus was demonstrated by contrast-enhanced CT scan and portography before discharge. Patients were discharged in 10–27 (19.25 ± 4.89) days after admission. No recurrence developed during the follow-up of 10–13 (12.13 ± 0.99) months.ConclusionsCatheter-directed thrombolytic and aspiration therapy via SMV+SMA is beneficial for ASMVT in avoiding patient death, efficient resolving thrombus, rapid improving symptoms, reversing extensive intestinal ischemia, averting bowel resection, or localizing infarcted bowel segment and preventing short bowel syndrome.« less

  12. Fibrin-Targeted Magnetic Resonance Imaging Allows In Vivo Quantification of Thrombus Fibrin Content and Identifies Thrombi Amenable for Thrombolysis

    PubMed Central

    Jenkins, Julia; Modarai, Bijan; Wiethoff, Andrea J.; Phinikaridou, Alkystis; Grover, Steven P.; Patel, Ashish S.; Schaeffter, Tobias; Smith, Alberto; Botnar, Rene M.

    2014-01-01

    Objective Deep venous thrombosis is a major health problem. Thrombolytic therapies are effective in recanalizing the veins and preventing post-thrombotic complications, but there is no consensus on selection criteria. The aim of this study was to investigate a fibrin-specific MRI contrast agent (EP-2104R) for the accurate quantification of thrombus’ fibrin content in vivo and for the identification of thrombus suitable for thrombolysis. Approach and Results Venous thrombosis was induced in the inferior vena cava of 8- to 10-week-old male BALB/C mice and MRI performed 2, 4, 7, 10, 14, and 21 days later. Eighteen mice were scanned at each time point pre and 2 hours post injection of EP-2104R (8.0 μmol/kg) with 12 mice at each time point used to correlate fibrin contrast uptake with thrombus’ histological stage and fibrin content. Six mice at each time point were immediately subjected to intravascular thrombolytic therapy (10 mg/kg of tissue-type plasminogen activator). Mice were imaged to assess response to lytic therapy 24 hours after thrombolytic treatment. Two mice at each time point were scanned post injection of 0.2 mmol/kg of Gd-DTPA (gadolinium with diethylenetriaminepentacetate, Magnevist, Schering AG, Berlin, Germany) for control purpose. Contrast uptake was correlated positively with the fibrin content of the thrombus measured by Western blotting (R2=0.889; P<0.001). Thrombus relaxation rate (R1) post contrast and the change in visualized thrombus size on late gadolinium enhancement inversion recovery MRI pre–EP-2104R and post–EP-2104R injection were the best predictors for successful thrombolysis (area under the curve, 0.989 [95% confidence interval, 0.97–1.00] and 0.994 [95% confidence interval, 0.98–1.00] respectively). Conclusions MRI with a fibrin-specific contrast agent accurately estimates thrombus fibrin content in vivo and identifies thrombi that are amenable for thrombolysis. PMID:24723557

  13. A case report: a young waiter with Paget-Schroetter syndrome.

    PubMed

    Drakos, Nicholas; Gausche-Hill, Marianne

    2013-03-01

    Paget-Schroetter syndrome (PSS) is a rare presentation of primary axillary subclavian vein thrombosis that classically occurs in young men with a degree of underlying thoracic outlet syndrome after a period of upper extremity exertion. The primary complication of PSS is post-thrombotic syndrome, a result of chronic venous hypertension. To educate Emergency Physicians on this condition to potentiate timely diagnosis and appropriate disposition. A 29-year-old right-handed restaurant waiter presented with 3 days of non-painful, gradual-onset right upper extremity swelling with normal vital signs. The patient's history was otherwise notable for subjective fevers and a right forearm abrasion. Upon examination, the right upper extremity was neurovascularly intact and remarkable for uniform edema and erythema extending distally from the level of the mid-humerus. The primary differential diagnoses were deep venous thrombosis (DVT) vs. soft tissue infection. Venous phase contrast computed tomography did not reveal evidence of underlying soft tissue infection and was inconclusive regarding a DVT. Ultrasound demonstrated a right subclavian vein DVT. The patient was admitted and underwent thrombolysis, venolysis, and first rib resection and initiation of warfarin. PSS is a rare presentation of upper-extremity DVT occurring classically in patients without commonly recognized pro-thrombotic risk factors. PSS carries the potential of significant morbidity in the form of post-thrombotic syndrome and pulmonary embolism. Current literature suggests that optimal outcomes are achieved when treatment is initiated within 6 weeks of onset. The treatment paradigm calls for thrombolysis and, frequently, a first rib resection. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Assessment of ultrasound modulation of near infrared light on the quantification of scattering coefficient.

    PubMed

    Singh, M Suheshkumar; Yalavarthy, Phaneendra K; Vasu, R M; Rajan, K

    2010-07-01

    To assess the effect of ultrasound modulation of near infrared (NIR) light on the quantification of scattering coefficient in tissue-mimicking biological phantoms. A unique method to estimate the phase of the modulated NIR light making use of only time averaged intensity measurements using a charge coupled device camera is used in this investigation. These experimental measurements from tissue-mimicking biological phantoms are used to estimate the differential pathlength, in turn leading to estimation of optical scattering coefficient. A Monte-Carlo model based numerical estimation of phase in lieu of ultrasound modulation is performed to verify the experimental results. The results indicate that the ultrasound modulation of NIR light enhances the effective scattering coefficient. The observed effective scattering coefficient enhancement in tissue-mimicking viscoelastic phantoms increases with increasing ultrasound drive voltage. The same trend is noticed as the ultrasound modulation frequency approaches the natural vibration frequency of the phantom material. The contrast enhancement is less for the stiffer (larger storage modulus) tissue, mimicking tumor necrotic core, compared to the normal tissue. The ultrasound modulation of the insonified region leads to an increase in the effective number of scattering events experienced by NIR light, increasing the measured phase, causing the enhancement in the effective scattering coefficient. The ultrasound modulation of NIR light could provide better estimation of scattering coefficient. The observed local enhancement of the effective scattering coefficient, in the ultrasound focal region, is validated using both experimental measurements and Monte-Carlo simulations.

  15. Integration of Real-Time Intraoperative Contrast-Enhanced Ultrasound and Color Doppler Ultrasound in the Surgical Treatment of Spinal Cord Dural Arteriovenous Fistulas.

    PubMed

    Della Pepa, Giuseppe Maria; Sabatino, Giovanni; Sturiale, Carmelo Lucio; Marchese, Enrico; Puca, Alfredo; Olivi, Alessandro; Albanese, Alessio

    2018-04-01

    In the surgical treatment of spinal dural arteriovenous fistulas (DAVFs), intraoperative definition of anatomic characteristics of the DAVF and identification of the fistulous point is mandatory to effectively exclude the DAVF. Intraoperative ultrasound and contrast-enhanced ultrasound integrated with color Doppler ultrasound was applied in the surgical setting for a cervical DAVF to identify the fistulous point and evaluate correct occlusion of the fistula. Integration of intraoperative ultrasound and contrast-enhanced ultrasound is a simple, cost-effective technique that provides an opportunity for real-time dynamic visualization of DAVF vascular patterns, identification of the fistulous point, and assessment of correct exclusion. Compared with other intraoperative tools, such as indocyanine green videoangiography, it allows the surgeon to visualize hidden anatomic and vascular structures, minimizing surgical manipulation and guiding the surgeon during resection. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Time-reversal acoustics and ultrasound-assisted convection-enhanced drug delivery to the brain.

    PubMed

    Olbricht, William; Sistla, Manjari; Ghandi, Gaurav; Lewis, George; Sarvazyan, Armen

    2013-08-01

    Time-reversal acoustics is an effective way of focusing ultrasound deep inside heterogeneous media such as biological tissues. Convection-enhanced delivery is a method of delivering drugs into the brain by infusing them directly into the brain interstitium. These two technologies are combined in a focusing system that uses a "smart needle" to simultaneously infuse fluid into the brain and provide the necessary feedback for focusing ultrasound using time-reversal acoustics. The effects of time-reversal acoustics-focused ultrasound on the spatial distribution of infused low- and high-molecular weight tracer molecules are examined in live, anesthetized rats. Results show that exposing the rat brain to focused ultrasound significantly increases the penetration of infused compounds into the brain. The addition of stabilized microbubbles enhances the effect of ultrasound exposure.

  17. Opto-acoustic thrombolysis

    DOEpatents

    Celliers, Peter; Da Silva, Luiz; Glinsky, Michael; London, Richard; Maitland, Duncan; Matthews, Dennis; Fitch, Pat

    2000-01-01

    This invention is a catheter-based device for generating an ultrasound excitation in biological tissue. Pulsed laser light is guided through an optical fiber to provide the energy for producing the acoustic vibrations. The optical energy is deposited in a water-based absorbing fluid, e.g. saline, thrombolytic agent, blood or thrombus, and generates an acoustic impulse in the fluid through thermoelastic and/or thermodynamic mechanisms. By pulsing the laser at a repetition rate (which may vary from 10 Hz to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus or treating vasospasm. The catheter can also incorporate thrombolytic drug treatments as an adjunct therapy and it can be operated in conjunction with ultrasonic detection equipment for imaging and feedback control and with optical sensors for characterization of thrombus type and consistency.

  18. Extensive deep vein thrombosis following prolonged gaming (‘gamer’s thrombosis’): a case report

    PubMed Central

    2013-01-01

    Introduction The average time spent playing video games is increasing. Prolonged immobility associated with gaming may therefore be an important risk factor for venous thromboembolism. We report a case of deep vein thrombosis associated with prolonged playing of PlayStation® games. Case presentation A 31-year-old Caucasian man, an exterior painter, presented with a three-day history of left leg pain and swelling after playing PlayStation® games for almost eight hours a day for four consecutive days. Doppler ultrasound of the left leg confirmed extensive left leg deep venous thrombosis requiring thrombolysis and anticoagulation. Conclusions Video gaming should be considered a risk factor for venous thromboembolism. Further studies are needed to estimate the degree of risk associated with prolonged periods of playing video games, and education for preventing venous thrombosis should be provided to gamers. PMID:24192285

  19. New technology applications: thrombolysis of acute deep vein thrombosis.

    PubMed

    Marchigiano, Gail; Riendeau, Debra; Jo Morse, Carol

    2006-01-01

    Treatment of deep vein thrombosis traditionally has focused on preventing the potentially life-threatening complication of pulmonary embolism rather than on removing or reducing the thrombus. Although treatment with anticoagulants may prevent thrombus propagation, the body's intrinsic thrombolytic system is left to attempt clot dissolution. Because this natural process is generally ineffective in its ability to fully recanalize a proximal vein, the risks of recurrent thrombosis as well as the disabling complication of postthrombotic syndrome increase. Moreover, the long-term consequences of postthrombotic syndrome include pain, disability, and, for many, a significant decrease in the quality of life. Recent technology using high-frequency, low-power ultrasound, or mechanical thrombectomy with catheter-directed delivery of a thrombolytic drug directly into the clot is available and showing promise. Nurses are caring for patients who receive endovascular interventions with lytic infusions. The nursing challenge is to provide safe and effective patient care.

  20. Therapeutic Ultrasound Enhancement of Drug Delivery to Soft Tissues

    NASA Astrophysics Data System (ADS)

    Lewis, George; Wang, Peng; Lewis, George; Olbricht, William

    2009-04-01

    Effects of exposure to 1.58 MHz focused ultrasound on transport of Evans Blue Dye (EBD) in soft tissues are investigated when an external pressure gradient is applied to induce convective flow through the tissue. The magnitude of the external pressure gradient is chosen to simulate conditions in brain parenchyma during convection-enhanced drug delivery (CED) to the brain. EBD uptake and transport are measured in equine brain, avian muscle and agarose brain-mimicking phantoms. Results show that ultrasound enhances EBD uptake and transport, and the greatest enhancement occurs when the external pressure gradient is applied. The results suggest that exposure of the brain parenchyma to ultrasound could enhance penetration of material infused into the brain during CED therapy.

  1. VEGFR2-Targeted Ultrasound Imaging Agent Enhances the Detection of Ovarian Tumors at Early Stage in Laying Hens, a Preclinical Model of Spontaneous Ovarian Cancer.

    PubMed

    Barua, Animesh; Yellapa, Aparna; Bahr, Janice M; Machado, Sergio A; Bitterman, Pincas; Basu, Sanjib; Sharma, Sameer; Abramowicz, Jacques S

    2015-07-01

    Tumor-associated neoangiogenesis (TAN) is an early event in ovarian cancer (OVCA) development. Increased expression of vascular endothelial growth factor receptor 2 (VEGFR2) by TAN vessels presents a potential target for early detection by ultrasound imaging. The goal of this study was to examine the suitability of VEGFR2-targeted ultrasound contrast agents in detecting spontaneous OVCA in laying hens. Effects of VEGFR2-targeted contrast agents in enhancing the intensity of ultrasound imaging from spontaneous ovarian tumors in hens were examined in a cross-sectional study. Enhancement in the intensity of ultrasound imaging was determined before and after injection of VEGFR2-targeted contrast agents. All ultrasound images were digitally stored and analyzed off-line. Following scanning, ovarian tissues were collected and processed for histology and detection of VEGFR2-expressing microvessels. Enhancement in visualization of ovarian morphology was detected by gray-scale imaging following injection of VEGFR2-targeted contrast agents. Compared with pre-contrast, contrast imaging enhanced the intensities of ultrasound imaging significantly (p < 0.0001) irrespective of the pathological status of ovaries. In contrast to normal hens, the intensity of ultrasound imaging was significantly (p < 0.0001) higher in hens with early stage OVCA and increased further in hens with late stage OVCA. Higher intensities of ultrasound imaging in hens with OVCA were positively correlated with increased (p < 0.0001) frequencies of VEGFR2-expressing microvessels. The results of this study suggest that VEGFR2-targeted contrast agents enhance the visualization of spontaneous ovarian tumors in hens at early and late stages of OVCA. The laying hen may be a suitable model to test new imaging agents and develop targeted therapeutics. © The Author(s) 2014.

  2. STARTING-SICH Nomogram to Predict Symptomatic Intracerebral Hemorrhage After Intravenous Thrombolysis for Stroke.

    PubMed

    Cappellari, Manuel; Turcato, Gianni; Forlivesi, Stefano; Zivelonghi, Cecilia; Bovi, Paolo; Bonetti, Bruno; Toni, Danilo

    2018-02-01

    Symptomatic intracerebral hemorrhage (sICH) is a rare but the most feared complication of intravenous thrombolysis for ischemic stroke. We aimed to develop and validate a nomogram for individualized prediction of sICH in intravenous thrombolysis-treated stroke patients included in the multicenter SITS-ISTR (Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register). All patients registered in the SITS-ISTR by 179 Italian centers between May 2001 and March 2016 were originally included. The main outcome measure was sICH per the European Cooperative Acute Stroke Study II definition (any type of intracerebral hemorrhage with increase of ≥4 National Institutes of Health Stroke Scale score points from baseline or death <7 days). On the basis of multivariate logistic model, the nomogram was generated. We assessed the discriminative performance by using the area under the receiver-operating characteristic curve and calibration of risk prediction model by using the Hosmer-Lemeshow test. A total of 15 949 patients with complete data for generating the nomogram was randomly dichotomized into training (3/4; n=12 030) and test (1/4; n=3919) sets. After multivariate logistic regression, 10 variables remained independent predictors of sICH to compose the STARTING-SICH (systolic blood pressure, age, onset-to-treatment time for thrombolysis, National Institutes of Health Stroke Scale score, glucose, aspirin alone, aspirin plus clopidogrel, anticoagulant with INR ≤1.7, current infarction sign, hyperdense artery sign) nomogram. The area under the receiver-operating characteristic curve of STARTING-SICH was 0.739. Calibration was good ( P =0.327 for the Hosmer-Lemeshow test). The STARTING-SICH is the first nomogram developed and validated in a large SITS-ISTR cohort for individualized prediction of sICH in intravenous thrombolysis-treated stroke patients. © 2018 American Heart Association, Inc.

  3. Generalized Safety and Efficacy of Simplified Intravenous Thrombolysis Treatment (SMART) Criteria in Acute Ischemic Stroke: The MULTI SMART Study.

    PubMed

    Sørensen, Sigrid B; Barazangi, Nobl; Chen, Charlene; Wong, Christine; Grosvenor, David; Rose, Jack; Bedenk, Ann; Morrow, Megan; McDermott, Dan; Hove, Jens D; Tong, David C

    2016-05-01

    Common intravenous recombinant tissue plasminogen activator (IV rt-PA) exclusion criteria may substantially limit the use of thrombolysis. Preliminary data have shown that the SMART (Simplified Management of Acute stroke using Revised Treatment) criteria greatly expand patient eligibility by reducing thrombolysis exclusions, but they have not been assessed on a large scale. We evaluated the safety and efficacy of general adoption of SMART thrombolysis criteria to a large regional stroke network. Retrospective analysis of consecutive patients who received IV thrombolysis within a regional stroke network was performed. Patients were divided into those receiving thrombolysis locally versus at an outside hospital. The primary outcome was modified Rankin Scale score (≤1) at discharge and the main safety outcome was symptomatic intracranial hemorrhage (sICH) rate. There were 539 consecutive patients, and 50.5% received thrombolysis at an outside facility. Ninety percent of the patients possessed common conventional IV rt-PA contraindications. There were no significant differences between local and network treated patients in favorable outcome (45.4% versus 37.4%; odds ratio [OR], .72; P > .09), mortality (9% versus 14%; OR, 1.6; P > .07), or sICH rate (2.6% versus 5.1%; OR, 2.0; P = .13). Multivariate analysis showed no association between receiving IV rt-PA at an outlying spoke hospital and higher rate of sICH or worse outcome at discharge. Generalized application of SMART criteria is safe and effective. Widespread application of these criteria could substantially increase the proportion of patients who might qualify for treatment. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. [Results of thrombolyses procedures in acute ischemic cerebral stroke realized in Kraków 2004-2007--Grant Ministry of Science and Information].

    PubMed

    Popiela, Tadeusz J; Urbanik, Andrzej; Słowik, Agnieszka

    2010-01-01

    To lower the number of complications of acute cerebral ischemic stroke and to reduce the time of rehabilitation in these patients it is necessary to induce treatment within the first 3 hours of the onset of the stroke. Early intervention however, is possible only in cases with the confirm localized ischemic focus visualized in one of the diagnostic imaging methods. The most widespread is CT, hovewer the first symptoms of ischemic stroke can be seen not beforel2 hours of the onset. The study evaluated the effectiveness of early diagnostics of ischemic stroke using perfusion CT (pCT) with subsequent intravenous or intra-arterial thrombolysis. The patients with ischemic stroke confirmed by pCT and qualified to thrombolysis in the first 3 hours of the onset of the stroke were randomly selected to intravenous or intra-arterial thrmobolysis. Those, who were 3 to 6 hours of the onset of the stroke were qualified to intra-arterial thrombolysis. A study group consisted of 377 patients hospitalized due to ischemic stroke. Of these pCT was performed in 76 cases, intravenous thrombolysis in 4 and intra-arterial thrombolysis in 2. Clinical condition substantially improved in 3 patients. Obtained results indicate the necessity to introduce pCT to the routine diagnostics of the acute ischemic stroke. A small number of patients eligible for thrombolysis does not allow to compare the effectiveness of intra-arterial and intravenous thrombolysis, however the project allowed to work out the efficient system of diagnostics and treatment of the acute ischemic stroke in the area of Krakow based on the standards used in the European countries.

  5. Thrombolysis and outcome of young stroke patients over the last decade: insights from the Nationwide Inpatient Sample.

    PubMed

    Kansara, Amit; Chaturvedi, Seemant; Bhattacharya, Pratik

    2013-08-01

    A recent study found a trend toward increasing hospitalizations for acute ischemic stroke (AIS) among young adults, raising concern for this subgroup. In the present study, we evaluated trends of use of thrombolysis and outcome among young adults (19-44 years of age) with AIS using a nationally representative administrative database. Discharge data were obtained from Nationwide Inpatient Sample between 2001 and 2009. Hospitalizations with a discharge diagnosis of AIS for patients 19 to 44 years of age were included. Use of thrombolysis was determined within this subset. The Cochran-Armitage test was used for trend analysis. Thrombolysis in young patients with AIS increased from 354 (1.84%) in 2001 to 1,237 (4.97%) in 2009 (P < .0001). The highest increase was noted at urban teaching hospitals. There was a progressive decrease in mortality in young AIS patients, from 6.81% in 2001 to 5.43% in 2009 (trend P = .027) and significant increase in discharges to rehabilitation (3.42% in 2002 to 12.7% in 2009 [trend P < .0001]). Discharge to other facilities decreased significantly (29.1% in 2001 to 17.8% in 2009 [trend P < .0001]). The rate of intracranial hemorrhage (2.70% in 2001; 2.69% in 2009) did not show any significant change despite the increase in the use of thrombolysis (trend P = .39). The rate of thrombolysis among young patients with AIS increased significantly between 2001 and 2009. A decrease in deaths with increased rehabilitation placements of young patients with AIS was noted over the last decade, suggesting improving outcomes. The lower rate of use of thrombolysis in rural hospitals may be improved with the widespread use of telestroke. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  6. Management and outcomes of acute ST-segment-elevation myocardial infarction at a tertiary-care hospital in Sri Lanka: an observational study.

    PubMed

    Bandara, Ruwanthi; Medagama, Arjuna; Munasinghe, Ruwan; Dinamithra, Nandana; Subasinghe, Amila; Herath, Jayantha; Ratnayake, Mahesh; Imbulpitiya, Buddhini; Sulaiman, Ameena

    2015-01-15

    Sri Lanka is a developing country with a high rate of cardiovascular mortality. It is still largely dependent on thrombolysis for primary management of acute myocardial infarction. The aim of this study was to present current data on the presentation, management, and outcomes of acute ST-segment-elevation myocardial infarction (STEMI) at a tertiary-care hospital in Sri Lanka. Eighty-one patients with acute STEMI presenting to a teaching hospital in Peradeniya, Sri Lanka, were included in this observational study. Median interval between symptom onset and hospital presentation was 60 min (mean 212 min). Thrombolysis was performed in 73% of patients. The most common single reason for not performing thrombolysis was delayed presentation. Median door-to-needle time was 64 min (mean, 98 min). Only 16.9% of patients received thrombolysis within 30 min, and none underwent primary PCI. Over 98% of patients received aspirin, clopidogrel, and a statin on admission. Intravenous and oral beta blockers were rarely used. Follow-up data were available for 93.8% of patients at 1 year. One-year mortality rate was 12.3%. Coronary intervention was performed in only 7.3% of patients post infarction. Late presentation to hospital remains a critical factor in thrombolysis of STEMI patients in Sri Lanka. Thrombolysis was not performed within 30 min of admission in the majority of patients. First-contact physicians should receive further training on effective thrombolysis, and there is an urgent need to explore the ways in which PCI and post-infarction interventions can be incorporated into treatment protocols.

  7. Intravenous thrombolysis in ischemic stroke with unknown onset using CT perfusion.

    PubMed

    Cortijo, E; García-Bermejo, P; Calleja, A I; Pérez-Fernández, S; Gómez, R; del Monte, J M; Reyes, J; Arenillas, J F

    2014-03-01

    Acute ischemic stroke patients with unclear onset time presenting >4.5 h from last-seen-normal (LSN) time are considered late patients and excluded from i.v. thrombolysis. We aimed to evaluate whether this subgroup of patients is different from patients presenting >4.5 h from a witnessed onset, in terms of eligibility and response to computed tomography perfusion (CTP)-guided i.v. thrombolysis. We prospectively studied consecutive acute non-lacunar middle cerebral artery (MCA) ischemic stroke patients presenting >4.5 h from LSN. All patients underwent multimodal CT and were considered eligible for i.v. thrombolysis according to CTP criteria. Two patient groups were established based on the knowledge of the stroke onset time. We compared the proportion of candidates suitable for intravenous thrombolysis between both groups, and their outcome after thrombolytic therapy. Among 147 MCA ischemic stroke patients presenting >4.5 h from LSN, stroke onset was witnessed in 74 and unknown in 73. Thirty-seven (50%) patients in the first group and 32 (44%) in the second met CTP criteria for thrombolysis (P = 0.7). Baseline variables were comparable between both groups with the exception of age, which was higher in the unclear onset group. The rates of early neurological improvement (54.1% vs 46.9%), 2-h MCA recanalization (43.5% vs 37%), symptomatic hemorrhagic transformation (3% vs 0%) and good 3-month functional outcome (62.2% vs 56.3%) did not differ significantly between both groups. Delayed stroke patients with unknown onset time were no different than patients >4.5 h regarding eligibility and response to CTP-based i.v. thrombolysis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. [Acute hepatic vascular complications].

    PubMed

    Ochs, A

    2011-07-01

    Acute hepatic vascular complications are rare. Acute portal vein thrombosis (PVT) and the Budd-Chiari syndrome (BSC) are the leading causes. Coagulopathy and local factors are present in up to 80% of cases. Diagnosis is established by colour-coded Doppler sonography, contrast-enhanced computed tomography or magnetic resonance imaging. Patients with acute PVT present with abdominal pain and disturbed intestinal motility. In the absence of cirrhosis anticoagulation with heparin is established followed by oral anticoagulation. In severe cases, surgical thrombectomy or transjugular thrombolysis with stent shunt may be necessary. Acute or fulminant BCS may require emergency liver transplantation or a transjugular intrahepatic portosystemic stent shunt, if patients present with acute liver failure. Milder cases receive anticoagulation for thrombolysis of occluded hepatic veins. Sinusoidal obstruction syndrome (SOS) is diagnosed after total body irradiation or chemotherapy, the term SOS replacing the former veno-occlusive disease. The treatment of congenital vascular malformations, complications in the setting of OLTX as well as patients with hepatic involvement of hereditary hemorrhagic telangiectasia requires significant expertise in a multidisciplinary approach.

  9. [Brain protection against cerebral ischemia].

    PubMed

    Kitagawa, Kazuo

    2013-01-01

    Previous clinical trials failed to show the benefit of several potentially protective drugs in acute ischemic stroke. However, there would be three main approaches for brain protection against stroke. The first is to develop a novel thrombolytic agent which is more efficient and safer than alteplase. Tenecteplase and desmoteplase are in progress as a new thrombolytic drug. The second strategy is to augment collateral circulation through leptomeningeal anastomosis. Administration of G-CSF could enhance arteriogenesis, but it takes several days to develop functional collateral. For this purpose, partial aortic balloon clumping or stimulation of pterygopalatine ganglion may be promising. The third one is to protect neurovascular unit against reperfusion injury. Brain hypothermia is the most effective strategy in experimental ischemia, and the clinical trial for hypothermia combined with thrombolysis therapy is in progress. Activation of endogenous protective response, as presented by ischemic tolerance, has focused on remote ischemic conditioning. Although the precise mechanisms of remote preconditioning remain unclear, intermittent limb ischemia is a safe approach. Remote ischemic conditioning is now investigated in acute patients with thrombolysis therapy.

  10. Driving delivery vehicles with ultrasound ☆

    PubMed Central

    Ferrara, Katherine W.

    2009-01-01

    Therapeutic applications of ultrasound have been considered for over 40 years, with the mild hyperthermia and associated increases in perfusion produced by ultrasound harnessed in many of the earliest treatments. More recently, new mechanisms for ultrasound-based or ultrasound-enhanced therapies have been described, and there is now great momentum and enthusiasm for the clinical translation of these techniques. This dedicated issue of Advanced Drug Delivery Reviews, entitled “Ultrasound for Drug and Gene Delivery,” addresses the mechanisms by which ultrasound can enhance local drug and gene delivery and the applications that have been demonstrated at this time. In this commentary, the identified mechanisms, delivery vehicles, applications and current bottlenecks for translation of these techniques are summarized. PMID:18479775

  11. Time-reversal acoustics and ultrasound-assisted convection-enhanced drug delivery to the brain

    PubMed Central

    Olbricht, William; Sistla, Manjari; Ghandi, Gaurav; Lewis, George; Sarvazyan, Armen

    2013-01-01

    Time-reversal acoustics is an effective way of focusing ultrasound deep inside heterogeneous media such as biological tissues. Convection-enhanced delivery is a method of delivering drugs into the brain by infusing them directly into the brain interstitium. These two technologies are combined in a focusing system that uses a “smart needle” to simultaneously infuse fluid into the brain and provide the necessary feedback for focusing ultrasound using time-reversal acoustics. The effects of time-reversal acoustics-focused ultrasound on the spatial distribution of infused low- and high-molecular weight tracer molecules are examined in live, anesthetized rats. Results show that exposing the rat brain to focused ultrasound significantly increases the penetration of infused compounds into the brain. The addition of stabilized microbubbles enhances the effect of ultrasound exposure. PMID:23927197

  12. Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays

    DTIC Science & Technology

    2001-10-25

    81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased

  13. Understanding clinicians' decisions to offer intravenous thrombolytic treatment to patients with acute ischaemic stroke: a protocol for a discrete choice experiment.

    PubMed

    De Brún, Aoife; Flynn, Darren; Joyce, Kerry; Ternent, Laura; Price, Christopher; Rodgers, Helen; Ford, Gary A; Lancsar, Emily; Rudd, Matthew; Thomson, Richard G

    2014-07-09

    Intravenous thrombolysis is an effective emergency treatment for acute ischaemic stroke for patients meeting specific criteria. Approximately 12% of eligible patients in England, Wales and Northern Ireland received thrombolysis in the first quarter of 2013, yet as many as 15% are eligible to receive treatment. Suboptimal use of thrombolysis may have been largely attributable to structural factors; however, with the widespread implementation of 24/7 hyper acute stroke services, continuing variation is likely to reflect differences in clinical decision-making, in particular the influence of ambiguous areas within the guidelines, licensing criteria and research evidence. Clinicians' perceptions about thrombolysis may now exert a greater influence on treatment rates than structural/service factors. This research seeks to elucidate factors influencing thrombolysis decision-making by using patient vignettes to identify (1) patient-related and clinician-related factors that may help to explain variation in treatment and (2) associated trade-offs in decision-making based on the interplay of critical factors. A discrete choice experiment (DCE) will be conducted to better understand how clinicians make decisions about whether or not to offer thrombolysis to patients with acute ischaemic stroke. To inform the design, exploratory work will be undertaken to ensure that (1) all potentially influential factors are considered for inclusion; and (2) to gain insights into the 'grey areas' of patient factors. A fractional factorial design will be used to combine levels of patient factors in vignettes, which will be presented to clinicians to allow estimation of the variable effects on decisions to offer thrombolysis. Ethical approval for this study was obtained from the Newcastle University Research Ethics Committee. The results will be disseminated in peer review publications and at national conferences. Findings will be translated into continuing professional development activities and will support implementation of a computerised decision aid for thrombolysis (COMPASS) in acute stroke care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Functional outcome after primary endovascular therapy or IV thrombolysis alone for stroke. An observational, comparative effectiveness study.

    PubMed

    Abilleira, Sònia; Ribera, Aida; Dávalos, Antonio; Ribó, Marc; Chamorro, Angel; Cardona, Pere; Molina, Carlos A; Martínez-Yélamos, Antonio; Urra, Xabier; Dorado, Laura; Roquer, Jaume; Martí-Fàbregas, Joan; Aja, Lucía; Tomasello, Alejandro; Castaño, Carlos; Blasco, Jordi; Cánovas, David; Castellanos, Mar; Krupinski, Jerzy; Guimaraens, Leopoldo; Perendreu, Joan; Ustrell, Xavier; Purroy, Francisco; Gómez-Choco, Manuel; Baiges, Joan Josep; Cocho, Dolores; Saura, Júlia; Gallofré, Miquel

    2014-01-01

    Among the acute ischemic stroke patients with large vessel occlusions and contraindications for the use of IV thrombolysis, mainly on oral anticoagulation or presenting too late, primary endovascular therapy is often performed as an alternative to the standard therapy even though evidence supporting the use of endovascular reperfusion therapies is not yet established. Using different statistical approaches, we compared the functional independence rates at 3 months among patients undergoing primary endovascular therapy and patients treated only with IV thrombolysis. We used data from a prospective, government-mandated and externally audited registry of reperfusion therapies for ischemic stroke (January 2011 to November 2012). Patients were selected if treated with either IV thrombolysis alone (n = 1,582) or primary endovascular thrombectomy (n = 250). A series of exclusions were made to homogenize the clinical characteristics among the two groups. We then carried out multivariate logistic regression and propensity score matching analyses on the final study sample (n = 1,179) to compare functional independence at 3 months, as measured by the modified Rankin scale scores 0-2, between the two groups. The unadjusted likelihood of good outcome was poorer among the endovascular group (OR: 0.69; 95% CI: 0.47-1.0). After adjustment, no differences by treatment modality were seen (OR: 1.51; 95% CI: 0.93-2.43 for primary endovascular therapy). Patients undergoing endovascular thrombectomy within 180-270 min (OR: 2.89; 95% CI: 1.17-7.15) and patients with severe strokes (OR: 1.84; 95% CI: 1.02-3.35) did better than their intravenous thrombolysis counterparts. The propensity score-matched analyses with and without adjustment by additional covariates showed that endovascular thrombectomy was as effective as intravenous thrombolysis alone in achieving functional independence (OR for unadjusted propensity score matched: 1.35; 95% CI: 0.9-2.02, OR for adjusted propensity score matched: 1.45; 95% CI: 0.91-2.32). This comparative effectiveness study shows that in ischemic stroke patients with contraindications for IV thrombolysis, primary endovascular treatment might be an alternative therapy at least as effective as IV thrombolysis alone. Randomized controlled trials are urgently needed. © 2014 S. Karger AG, Basel.

  15. Clinical effectiveness and cost-effectiveness of immediate angioplasty for acute myocardial infarction: systematic review and economic evaluation.

    PubMed

    Hartwell, D; Colquitt, J; Loveman, E; Clegg, A J; Brodin, H; Waugh, N; Royle, P; Davidson, P; Vale, L; MacKenzie, L

    2005-05-01

    To review the clinical evidence comparing immediate angioplasty with thrombolysis, and to consider whether it would be cost-effective. Electronic databases. Experts in the field. For clinical effectiveness, a comprehensive review of randomised control trials (RCTs) was used for efficacy, and a selection of observational studies such as case series or audit data used for effectiveness in routine practice. RCTs of thrombolysis were used to assess the relative value of prehospital and hospital thrombolysis. Observational studies were used to assess the representativeness of patients in the RCTs, and to determine whether different groups have different capacity to benefit. Clinical effectiveness was synthesised through a narrative review with full tabulation of results of all included studies and a meta-analysis to provide a precise estimate of absolute clinical benefit. Consideration was given to the effect of the growing use of stents. The economic modelling adopted an NHS perspective to develop a decision-analytical model of cost-effectiveness focusing on opportunity costs over the short term (6 months). The results were consistent in showing an advantage of immediate angioplasty over hospital thrombolysis. The updated meta-analysis showed that mortality is reduced by about one-third, from 7.6% to 4.9% in the first 6 months, and by about the same in studies of up to 24 months. Reinfarction is reduced by over half, from 7.6% to 3.1%. Stroke is reduced by about two-thirds, from 2.3% with thrombolysis to 0.7% with percutaneous coronary intervention (PCI), with the difference being due to haemorrhagic stroke. The need for coronary artery bypass graft is reduced by about one-third, from 13.2% to 8.4%. Caution is needed in interpreting some of the older trials, as changes such as an increase in stenting and the use of the glycoprotein IIb/IIa inhibitors may improve the results of PCI. There is little evidence comparing prehospital thrombolysis with immediate PCI. Research on thrombolysis followed by PCI, known as 'facilitated PCI', is underway, but results are not yet available. Trials may be done in select centres and results may not be as good in lower volume centres, or out of normal working hours. In addition, much of the marginal mortality benefit of PCI over hospital thrombolysis may be lost if door-to-balloon time were more than an hour longer than door-to-needle time. Conversely, within the initial 6 hours, the later patients present, the greater the relative advantage of PCI. Results suggest that PCI is more cost-effective than thrombolysis, providing additional benefits in health status at some extra cost. In the longer term, the cost difference is expected to be reduced because of higher recurrence and reintervention rates among those who had thrombolysis. If both interventions were routinely available, the economic analysis favours PCI, given the assumptions of the model. However, very few units in England could offer a routine immediate PCI service at present, and there would be considerable resource implications of setting up such services. Without a detailed survey of existing provision, it is not possible to quantify the implications, but they include both capital and revenue: an increase in catheter laboratory provision and running costs. The greatest problem would be staffing, and that would take some years to resolve. A gradual incrementalist approach based on clinical networks, with transfer to centres able to offer PCI, may be used. In rural areas, one option may be to promote an increase in prehospital thrombolysis, with PCI for thrombolysis failures. There is a need for data on the long-term consequences of treatment, the quality of life of patients after treatment, and the effects of PCI following thrombolysis failure.

  16. EFSUMB guidelines 2011: comment on emergent indications and visions.

    PubMed

    Dietrich, C F; Cui, X W; Barreiros, A P; Hocke, M; Ignee, A

    2012-07-01

    The focus of this article is the emergent and potential indications of contrast-enhanced ultrasound (CEUS). Emergent applications of CEUS techniques include extravascular and intracavitary contrast-enhanced ultrasound, quantitative assessment of microvascular circulation for tumor response assessment, and tumor characterization using dynamic contrast-enhanced ultrasound (DCE-US). Potential indications for microbubble agents include novel molecular imaging and drug and gene delivery techniques, which have been successfully tested in animal models. "Comments and Illustrations of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Non-Liver Guidelines 2011" which focus more on established applications are published in the same supplement to Ultraschall in der Medizin (European Journal of Ultrasound). © Georg Thieme Verlag KG Stuttgart · New York.

  17. Microbubble-enhanced ultrasound to demonstrate urethral transection in a case of penile fracture.

    PubMed

    Czarnecki, Oliver; von Stempel, Conrad Brice; Sangster, Pippa; Walkden, Miles

    2017-09-23

    A 47-year-old man attended the emergency department following trauma during sexual intercourse after which he developed penile swelling and haematuria several hours later. A penile fracture was suspected but given the slightly atypical history, ultrasound was performed to look for a fracture. Given the history of haematuria, both a standard Doppler ultrasound and a microbubble-enhanced retrograde ultrasound urethrogram were performed. The Doppler confirmed the suspected diagnosis of penile fracture, and microbubble urethrogram demonstrated a urethral injury. This facilitated prompt surgical treatment and helped guide the surgical approach. Retrograde microbubble enhanced ultrasound urethrogram is a novel technique that can be used in conjunction with standard ultrasound to confirm the presence of a concurrent urethral rupture in penile fracture. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Endocapsular hematoma: a rare form of ocular hemorrhage after thrombolysis with streptokinase.

    PubMed

    Dhawan, Bodhraj; Soni, Rhibhu; Singh, Rajbir; Vig, Vipan

    2014-08-01

    Endocapsular hematoma has previously been described as a cataract surgery complication more commonly observed in eyes receiving a combined cataract and glaucoma surgery. However, it can also be a rare form of ocular bleed following thrombolysis with streptokinase. A 65-year-old diabetic male presented to us with complain of sudden painless diminution of vision in his left eye, which he developed while he was being thrombolysed with streptokinase administered intravenously for an episode of acute myocardial infarct. On examination, left eye was pseudophakic with collection of blood in the capsular bag (Endocapsular hematoma). Endocapsular hematoma can be a rare form of ocular bleeding complicated by thrombolysis. Reporting this case becomes more relevant in the present era with increasing number of patients suffering from ischemic heart disease and likely to undergo thrombolysis.

  19. Minimum intravenous thrombolysis utilization rates in acute ischemic stroke to achieve population effects on disability: A discrete-event simulation model.

    PubMed

    Hoffmeister, Lorena; Lavados, Pablo M; Mar, Javier; Comas, Merce; Arrospide, Arantzazu; Castells, Xavier

    2016-06-15

    The only pharmacological treatment with proven cost-effectiveness in reducing acute ischemic stroke (AIS) associated disability is intravenous thrombolysis with recombinant tissue plasminogen activator but it's utilization rate is still low in most of the world. We estimated the minimum thrombolysis utilization rate needed to decrease the prevalence of stroke-related disability at a population level by using a discrete-event simulation model. The model included efficacy according to time to treatment up to 4.5h, and four scenarios for the utilization of intravenous thrombolysis in eligible patients with AIS: a) 2%; b) 12% c) 25% and d) 40%. We calculated the prevalence of AIS related disability in each scenario, using population based data. The simulation was performed from 2002 to 2017 using the ARENA software. A 2% utilization rate yielded a prevalence of disability of 359.1 per 100,000. Increasing thrombolysis to 12% avoided 779 disabled patients. If the utilization rate was increased to 25%, 1783 disabled patients would be avoided. The maximum scenario of 40% decreased disability to 335.7 per 100,000, avoiding 17% of AIS-related disability. The current utilization rate of intravenous thrombolysis of 2% has minimal population impact. Increasing the rate of utilization to more than 12% is the minimum to have a significant population effect on disability and should be a public policy aim. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A one-to-one telestroke network: the first Italian study of a web-based telemedicine system for thrombolysis delivery and patient monitoring.

    PubMed

    Nardetto, Lucia; Dario, Claudio; Tonello, Simone; Brunelli, Marta Carla; Lisiero, Manola; Carraro, Maria Grazia; Saccavini, Claudio; Scannapieco, Gianluigi; Giometto, Bruno

    2016-05-01

    Over 10 years after European approval, thrombolysis is still limited by a restricted time window and non-optimal territorial coverage. Implementation of telestroke can give a growing number of patients access to treatment. We hereby present the first Italian telemedicine study applied to both the acute and the monitoring phase of stroke care. From January 2011 to December 2013, we tested a web-based, drip, and treat interaction model, connecting the cerebrovascular specialist of one hub center to the Emergency Department of a Spoke center. We then compared thrombolysis delivered using the telestroke model with thrombolysis provided at the Hub Stroke Unit at the time when the telemedicine program was activated. Telethrombolysis data were then compared with data from the two main international telestroke projects (TEMPiS and REACH), and other European telestroke studies performed at the time of writing. We collected a total of 131 thrombolysis procedures (25 telethrombolysis and 106 thrombolysis patients at the Stroke Unit). Statistical analysis with the t test yielded no statistically significant differences between the two populations in door-to-scan, door-to-needle (DTN), and onset-to-treatment times (OTT). Our OTT and DTN pathway times were longer than the TEMPiS and REACH studies but comparable with other European telemedicine trials, despite different models of interaction and number of centers. Our study in a northeastern province of Italy confirms the potential of applying telemedicine to a cerebrovascular pathology.

  1. Diagnosis and treatment of shock due to massive pulmonary embolism: approach with transesophageal echocardiography and intrapulmonary thrombolysis.

    PubMed

    Krivec, B; Voga, G; Zuran, I; Skale, R; Pareznik, R; Podbregar, M; Noc, M

    1997-11-05

    To evaluate the diagnostic value of transesophageal echocardiography (TEE) as an initial diagnostic tool in shocked patients. The second objective was to study therapeutic impact of intrapulmonary thrombolysis in patients with diagnosed massive pulmonary embolism. Prospective observational study. Medical ICU in 800-bed general hospital. Twenty-four consecutive patients with unexplained shock and distended jugular veins. In 18 patients, right ventricular dilatation with global or segmental hypokinesis was documented. In addition, central pulmonary thromboemboli (12 patients), reduced contrast flow in right pulmonary artery (one patient), and right ventricular free wall akinesis (one patient) were found. No additional echocardiographic findings were apparent in four patients. According to pulmonary scintigraphy or autopsy, sensitivity of TEE for diagnosis of massive pulmonary embolism (MPE) in patients with right ventricular dilatation was 92% and specificity was 100%. In patients without right ventricular dilatation, left ventricular dysfunction (four patients) or cardiac tamponade (two patients) was confirmed. Intrapulmonary thrombolysis was evaluated in 11 of 13 patients with MPE. Two patients died prior to attempted thrombolysis. Three patients received streptokinase and eight received urokinase. Twenty-four hours after beginning of treatment, total pulmonary resistance index significantly decreased for 59% and mean pulmonary artery pressure for 31%. Cardiac index increased for 74%. Nine of 11 patients receiving thrombolysis survived to hospital discharge. Bedside TEE is a valuable tool for diagnosis of MPE. It enables immediate intrapulmonary thrombolysis, which seems to be an effective therapeutic alternative in our group of patients with obstructive shock.

  2. Thrombolysis for acute ischaemic stroke with alteplase in an Asian population: results of the multicenter, multinational Safe Implementation of Thrombolysis in Stroke-Non-European Union World (SITS-NEW).

    PubMed

    Rha, Joung-Ho; Shrivastava, Vasantha Padma; Wang, Yongjun; Lee, Kim En; Ahmed, Niaz; Bluhmki, Erich; Hermansson, Karin; Wahlgren, Nils

    2014-10-01

    Safe Implementation of Thrombolysis in Stroke-Non-European Union World was a multinational, prospective, open, monitored, observational study of intravenous alteplase as thrombolytic therapy in clinical practice. Safe Implementation of Thrombolysis in Stroke-Non-European Union World was required to assess the safety of alteplase in an Asian population by comparison with results from the European Safe Implementation of Thrombolysis in Stroke-Monitoring Study and pooled results from randomized controlled trials. To evaluate the efficacy and safety of intravenous alteplase (0·9 mg/kg) as thrombolytic therapy within three-hours of onset of acute ischaemic stroke in an Asian population. The 591 patients included were treated at 48 centers in four countries (South Korea, China, India, and Singapore) between 2006 and 2008. Primary outcomes were symptomatic (deterioration in National Institutes of Health Stroke Scale score ≥4 or death within the first 24 h) intracerebral haemorrhage type 2 22-36 h after the thrombolysis and mortality at three-month follow-up. The secondary outcome was functional independence (modified Rankin Scale score 0-2) at three-months. Results were compared with those from Safe Implementation of Thrombolysis in Stroke-Monitoring Study (n = 6483) and pooled results of patients (n = 415) who received intravenous alteplase (0·9 mg/kg) zero- to three-hours from onset of stroke symptoms in four randomized controlled trials (National Institute of Neurological Disorders and Stroke A and B, Altephase Thrombolysis for Acute Noninterventional Therapy in Ischaemic Stroke, and European Cooperative Acute Stroke Study II). Results are presented as Safe Implementation of Thrombolysis in Stroke-Non-European Union World vs. Safe Implementation of Thrombolysis in Stroke-Monitoring Study vs. pooled randomized controlled trials. Median age was 64 vs. 68 vs. 70 years, National Institutes of Health Stroke Scale score at baseline was 12 vs. 12 vs. 13, time from stroke onset to treatment was 130 vs. 140 vs. 135 mins, and females were 36·4% vs. 39·8% vs. 41·2%. Main outcomes (proportion of patients and 95% confidence intervals) were symptomatic intracerebral haemorrhage: 1·9% (1·1-3·3) vs. 1·7% (1·4-2·0) vs. 3·1% (1·8-5·3); mortality: 10·2% (8·0-12·9) vs. 11·3% (10·5-12·1) vs. 16·4% (13·1-20·3); and functional independence: 62·5% (58·5-66·4) vs. 54·8% (53·5-56·0) vs. 50·1% (45·3-54·9) at three-months. Adjusted odds ratio (95% confidence intervals) between Safe Implementation of Thrombolysis in Stroke-Non-European Union World and Safe Implementation of Thrombolysis in Stroke-Monitoring Study, and between Safe Implementation of Thrombolysis in Stroke-Non-European Union World and the pooled trials were 1·83 (0·89-3·77; P = 0·1156) and 0·63 (0·19-2·07; P = 0·4470) for symptomatic intracerebral haemorrhage, 0·90 (0·64-1·25; P = 0·5092) and 0·93 (0·52-1·64; P = 0·7915) for mortality at three-months, and 1·57 (1·25-1·96; P < 0·0001) and 1·35 (0·91-2·00; P = 0·1325) for functional independence. These data demonstrate the safety and efficacy of the standard dose of intravenous alteplase (0·9 mg/kg) in an Asian population, as previously observed in the European population studied in Safe Implementation of Thrombolysis in Stroke-Monitoring Study and the populations in pooled randomized controlled trials, when used in routine clinical practice within three-hours of stroke onset. The findings should encourage wider use of thrombolytic therapy in Asian countries for suitable patients treated in stroke centers. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.

  3. Thrombolysis and clinical outcome in patients with stroke after implementation of the Tyrol Stroke Pathway: a retrospective observational study.

    PubMed

    Willeit, Johann; Geley, Theresa; Schöch, Johannes; Rinner, Heinrich; Tür, Andreas; Kreuzer, Hans; Thiemann, Norbert; Knoflach, Michael; Toell, Thomas; Pechlaner, Raimund; Willeit, Karin; Klingler, Natalie; Praxmarer, Silvia; Baubin, Michael; Beck, Gertrud; Berek, Klaus; Dengg, Christian; Engelhardt, Klaus; Erlacher, Thomas; Fluckinger, Thomas; Grander, Wilhelm; Grossmann, Josef; Kathrein, Hermann; Kaiser, Norbert; Matosevic, Benjamin; Matzak, Heinrich; Mayr, Markus; Perfler, Robert; Poewe, Werner; Rauter, Alexandra; Schoenherr, Gudrun; Schoenherr, Hans-Robert; Schinnerl, Adolf; Spiss, Heinrich; Thurner, Theresa; Vergeiner, Gernot; Werner, Philipp; Wöll, Ewald; Willeit, Peter; Kiechl, Stefan

    2015-01-01

    Intravenous thrombolysis for ischaemic stroke remains underused worldwide. We aimed to assess whether our statewide comprehensive stroke management programme would improve thrombolysis use and clinical outcome in patients. In 2008-09, we designed the Tyrol Stroke Pathway, which provided information campaigns for the public and standardised the entire treatment pathway from stroke onset to outpatient rehabilitation. It was commenced in Tyrol, Austria, as a long-term routine-care programme and aimed to include all patients with stroke in the survey area. We focused on thrombolysis use and outcome in the first full 4 years of implementation (2010-13). We enrolled 4947 (99%) of 4992 patients with ischaemic stroke who were admitted to hospitals in Tyrol; 675 (14%) of the enrollees were treated with alteplase. Thrombolysis administration in Tyrol increased after programme implementation, from 160 of 1238 patients (12·9%, 95% CI 11·1-14·9) in 2010 to 213 of 1266 patients (16·8%, 14·8-19·0) in 2013 (ptrend 2010-13<0·0001). Differences in use of thrombolysis in the nine counties of Tyrol in 2010 (range, 2·2-22·6%) were reduced by 2013 (12·1-22·5%). Median statewide door-to-needle time decreased from 49 min (IQR 35-60) in 2010 to 44 min (29-60) in 2013; symptomatic post-thrombolysis intracerebral haemorrhages occurred in 28 of 675 patients (4·1%, 95% CI 2·8-5·9) during 2010-13. In four Austrian states without similar stroke programmes, thrombolysis administration remained stable or declined between 2010 and 2013 (mean reduction 14·4%, 95% CI 10·9-17·9). Although the 3-month mortality was not affected by our programme (137 [13%] of 1060 patients in 2010 vs 143 [13%] of 1069 patients in 2013), 3-month functional outcome significantly improved (modified Rankin Scale score 0-1 in 375 [40%] of 944 patients in 2010 vs 493 [53%] of 939 in 2013; score 0-2 in 531 [56%] patients in 2010 and 615 [65%] in 2013; ptrend 2010-13<0·0001). During the period of implementation of our comprehensive stroke management programme, thrombolysis administration increased and clinical outcome significantly improved, although mortality did not change. We hope that these results will guide health authorities and stroke physicians elsewhere when implementing similar programmes for patients with stroke. Reformpool of the Tyrolean Health Care Fund. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Ultrasound-enhanced ocular delivery of dexamethasone sodium phosphate: an in vivo study

    PubMed Central

    2014-01-01

    Background The eye's unique anatomy and its physiological and anatomical barriers can limit effective drug delivery into the eye. Methods An in vivo study was designed to determine the effectiveness and safety of ultrasound application in enhancing drug delivery in a rabbit model. Permeability of a steroid ophthalmic drug, dexamethasone sodium phosphate, was investigated in ultrasound- and sham-treated cases. For this study, an eye cup filled with dexamethasone sodium phosphate was placed on the cornea. Ultrasound was applied at intensity of 0.8 W/cm2 and frequency of 400 or 600 kHz for 5 min. The drug concentration in aqueous humor samples, collected 90 min after the treatment, was determined using chromatography methods. Light microscopy observations were done to determine the structural changes in the cornea as a result of ultrasound application. Results An increase in drug concentration in aqueous humor samples of 2.8 times (p < 0.05) with ultrasound application at 400 kHz and 2.4 times (p < 0.01) with ultrasound application at 600 kHz was observed as compared to sham-treated samples. Histological analysis showed that the structural changes in the corneas exposed to ultrasound predominantly consisted of minor epithelial disorganization. Conclusions Ultrasound application enhanced the delivery of an anti-inflammatory ocular drug, dexamethasone sodium phosphate, through the cornea in vivo. Ultrasound-enhanced ocular drug delivery appears to be a promising area of research with a potential future application in a clinical setting. PMID:24921047

  5. Biodegradable double-targeted PTX-mPEG-PLGA nanoparticles for ultrasound contrast enhanced imaging and antitumor therapy in vitro.

    PubMed

    Ma, Jing; Shen, Ming; Xu, Chang Song; Sun, Ying; Duan, You Rong; Du, Lian Fang

    2016-11-29

    A porous-structure nano-scale ultrasound contrast agent (UCA) was made of monomethoxypoly (ethylene glycol)-poly (lactic-co-glycolic acid) (mPEG-PLGA), and modified by double-targeted antibody: anti-carcinoembryonic antigen (CEA) and anti-carbohydrate antigen 19-9 (CA19-9), as a double-targeted nanoparticles (NPs). Anti-tumor drug paclitaxel (PTX) was encapsulated in the double-targeted nanoparticles (NPs). The morphor and release curve were characterized. We verified a certain anticancer effect of PTX-NPs through cytotoxicity experiments. The cell uptake result showed much more NPs may be facilitated to ingress the cells or tissues with ultrasound (US) or ultrasound targeted microbubble destruction (UTMD) transient sonoporation in vitro. Ultrasound contrast-enhanced images in vitro and in vivo were investigated. Compared with SonoVue, the NPs prolonged imaging time in rabbit kidneys and tumor of nude mice, which make it possible to further enhance anti-tumor effects by extending retention time in the tumor region. The novel double-targeted NPs with the function of ultrasound contrast enhanced imaging and anti-tumor therapy can be a promising way in clinic.

  6. [Intravenous thrombolysis for acute ischemic stroke. A four years’ experience in a Chilean public hospital].

    PubMed

    Soto V, Álvaro; Morales I, Gladys; Grandjean B, Marcela; Pollak W, Débora; Del Castillo C, Carolina; García F, Pía; Von Johnn A, Alexis; Riquelme G, Alfonso

    2017-04-01

    Intravenous thrombolysis (IVT) with alteplase (tissue plasminogen activator) is the standard pharmacological treatment in acute ischemic stroke (AIS), reducing disability in patients. To report the results a thrombolysis protocol during four years in a regional public hospital. Data from 106 consecutive patients aged 68 ± 13 years (57% men) who were treated with IVT, from May 2012 until April 2016, was analyzed. The median door-to-needle time was 80 minutes (interquartile range = 57-113). The median National Institute of Health Stroke Scale (NIHSS) scores on admission and at discharge were was 11.5 and 5 points respectively. At discharge, 27% of hospitalized patients had a favorable outcome (n = 99), defined as having 0 to 1 points in the modified Rankin scale. Symptomatic intracerebral hemorrhage and mortality rates were 5.7 and 13.1%, respectively. The thrombolysis rate rose from 0.7% in 2012 to 6% in 2016. The implementation of 24/7 neurology shifts in the Emergency Department allowed us to increase the amount and quality of IVT in our hospital, as measured by the rate of thrombolysis and by process indicators such as door-to-needle time.

  7. Bioconjugation of recombinant tissue plasminogen activator to magnetic nanocarriers for targeted thrombolysis

    PubMed Central

    Yang, Hung-Wei; Hua, Mu-Yi; Lin, Kun-Ju; Wey, Shiaw-Pyng; Tsai, Rung-Ywan; Wu, Siao-Yun; Lu, Yi-Ching; Liu, Hao-Li; Wu, Tony; Ma, Yunn-Hwa

    2012-01-01

    Low-toxicity magnetic nanocarriers (MNCs) composed of a shell of poly [aniline-co-N-(1-one-butyric acid) aniline] over a Fe3O4 magnetic nanoparticle core were developed to carry recombinant tissue plasminogen activator (rtPA) in MNC-rtPA for targeted thrombolysis. With an average diameter of 14.8 nm, the MNCs exerted superparamagnetic properties. Up to 276 μg of active rtPA was immobilized per mg of MNCs, and the stability of the immobilized rtPA was greatly improved during storage at 4°C and 25°C. In vitro thrombolysis testing with a tubing system demonstrated that magnet-guided MNC-rtPA showed significantly improved thrombolysis compared with free rtPA and reduced the clot lysis time from 39.2 ± 3.2 minutes to 10.8 ± 4.2 minutes. In addition, magnet-guided MNC-rtPA at 20% of the regular rtPA dose restored blood flow within 15–25 minutes of treatment in a rat embolism model without triggering hematological toxicity. In conclusion, this improved system is based on magnetic targeting accelerated thrombolysis and is potentially amenable to therapeutic applications in thromboembolic diseases. PMID:23055728

  8. Intra-arterial thrombolysis of digital artery occlusions in a patient with polycythemia vera.

    PubMed

    Jud, Philipp; Hafner, Franz; Gary, Thomas; Ghanim, Leyla; Lipp, Rainer; Brodmann, Marianne

    2017-01-01

    There are limited therapeutic options for the resolution of digital artery occlusions. Intra-arterial thrombolysis with anticoagulative and thrombolytic drugs successfully restored the blood flow in the affected digital arteries.

  9. A qualitative study of paramedics' attitudes to providing prehospital thrombolysis

    PubMed Central

    Price, L; Keeling, P; Brown, G; Hughes, D; Barton, A

    2005-01-01

    Method: In-depth interviews with 20 paramedics were recorded and transcribed and analysed for emergent themes using the constant comparative method. Results: Although there was a will to provide PHT because of its benefits to patients, its associated risks, aspects of pay and working conditions, and certain organisational factors undermined the willingness of some paramedics to administer thrombolysis. The eight minute response time standard is a competing imperative which can delay thrombolysis. Conclusions: A minority of paramedics are likely to be unwilling to deliver PHT unless countervailing imperatives are addressed. PMID:16189044

  10. Spontaneous Splenic Rupture Following Intravenous Thrombolysis with Alteplase Applied as Stroke Therapy – Case Report and Review of Literature

    PubMed Central

    Aleksic-Shihabi, Anka; Jadrijevic, Eni; Milekic, Nina; Bulicic, Ana Repic; Titlic, Marina; Suljic, Enra

    2016-01-01

    Introduction: Stroke is a medical emergency in neurology, and is one of the leading causes of death nowadays. At a recent time, a therapeutic method used in adequate conditions is thrombolysis, a treatment of an emerging clot in the brain vascular system by alteplase. The application of alteplase also has a high risk of life threatening conditions. Case report: This is a brief report of a case with thrombolysis complication which manifested as a spleen rupture. PMID:26980937

  11. Time-dependent change of blood flow in the prostate treated with high-intensity focused ultrasound.

    PubMed

    Shoji, Sunao; Tonooka, Akiko; Hashimoto, Akio; Nakamoto, Masahiko; Tomonaga, Tetsuro; Nakano, Mayura; Sato, Haruhiro; Terachi, Toshiro; Koike, Junki; Uchida, Toyoaki

    2014-09-01

    Avascular areas on contrast-enhanced magnetic resonance imaging have been considered to be areas of localized prostate cancer successfully treated by high-intensity focused ultrasound. However, the optimal timing of magnetic resonance imaging has not been discussed. The thermal effect of high-intensity focused ultrasound is degraded by regional prostatic blood flow. Conversely, the mechanical effect of high-intensity focused ultrasound (cavitation) is not affected by blood flow, and can induce vessel damage. In this series, the longitudinal change of blood flow on contrast-enhanced magnetic resonance imaging was observed from postoperative day 1 to postoperative day 14 in 10 patients treated with high-intensity focused ultrasound. The median rates of increase in the non-enhanced volume of the whole gland, transition zone and peripheral zone from postoperative day 1 to postoperative day 14 were 36%, 39%, and 34%, respectively. In another pathological analysis of the prostate tissue of 17 patients immediately after high-intensity focused ultrasound without neoadjuvant hormonal therapy, we observed diffuse coagulative degeneration and partial non-coagulative prostate tissue around arteries with vascular endothelial cell detachment. These observations on contrast-enhanced magnetic resonance imaging support a time-dependent change of the blood flow in the prostate treated with high-intensity focused ultrasound. Additionally, our pathological findings support the longitudinal changes of these magnetic resonance imaging findings. Further large-scale studies will investigate the most appropriate timing of contrast-enhanced magnetic resonance imaging for evaluation of the effectiveness of high-intensity focused ultrasound for localized prostate cancer. © 2014 The Japanese Urological Association.

  12. Spontaneous sternocleidomastoid muscle hematoma following thrombolysis for acute ischemic stroke.

    PubMed

    Giannantoni, Nadia Mariagrazia; Della Marca, Giacomo; Broccolini, Aldobrando; Pilato, Fabio; Profice, Paolo; Morosetti, Roberta; Caliandro, Pietro; Frisullo, Giovanni

    2014-06-15

    Spontaneous or traumatic bleeding is a common complication of systemic thrombolysis in patients with acute ischemic stroke. We report the case of an 83 y.o. woman with right facio-brachio-crural hemiparesis, left deviation of the head and aphasia who developed, after thrombolytic therapy, a spontaneous sternocleidomastoid muscle hematoma that regressed few days later. To our knowledge, this is the first case reported in the literature of asymptomatic and spontaneous skeletal muscle hematoma following thrombolysis for the treatment of acute ischemic stroke. The occurrence of lateral cervical tuberculosis lymphadenitis ipsilateral to sternocleidomastoid muscle hematoma may suggest a causal relationship between local chronic inflammation of active mycobacterial infection and thrombolysis-related extravasation. This case should suggest caution in thrombolytic treatment in patients with chronic immune dysregulation and vascular inflammation such as extra-pulmonary tuberculosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Cavitation-enhanced delivery of a replicating oncolytic adenovirus to tumors using focused ultrasound.

    PubMed

    Bazan-Peregrino, Miriam; Rifai, Bassel; Carlisle, Robert C; Choi, James; Arvanitis, Costas D; Seymour, Leonard W; Coussios, Constantin C

    2013-07-10

    Oncolytic viruses (OV) and ultrasound-enhanced drug delivery are powerful novel technologies. OV selectively self-amplify and kill cancer cells but their clinical use has been restricted by limited delivery from the bloodstream into the tumor. Ultrasound has been previously exploited for targeted release of OV in vivo, but its use to induce cavitation, microbubble oscillations, for enhanced OV tumor extravasation and delivery has not been previously reported. By identifying and optimizing the underlying physical mechanism, this work demonstrates that focused ultrasound significantly enhances the delivery and biodistribution of systemically administered OV co-injected with microbubbles. Up to a fiftyfold increase in tumor transgene expression was achieved, without any observable tissue damage. Ultrasound exposure parameters were optimized as a function of tumor reperfusion time to sustain inertial cavitation, a type of microbubble activity, throughout the exposure. Passive detection of acoustic emissions during treatment confirmed inertial cavitation as the mechanism responsible for enhanced delivery and enabled real-time monitoring of successful viral delivery. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. The EFSUMB Guidelines and Recommendations for the Clinical Practice of Contrast-Enhanced Ultrasound (CEUS) in Non-Hepatic Applications: Update 2017 (Short Version).

    PubMed

    Sidhu, Paul S; Cantisani, Vito; Dietrich, Christoph F; Gilja, Odd Helge; Saftoiu, Adrian; Bartels, Eva; Bertolotto, Michele; Calliada, Fabrizio; Clevert, Dirk-André; Cosgrove, David; Deganello, Annamaria; D'Onofrio, Mirko; Drudi, Francesco Maria; Freeman, Simon; Harvey, Christopher; Jenssen, Christian; Jung, Ernst-Michael; Klauser, Andrea Sabine; Lassau, Nathalie; Meloni, Maria Franca; Leen, Edward; Nicolau, Carlos; Nolsoe, Christian; Piscaglia, Fabio; Prada, Francesco; Prosch, Helmut; Radzina, Maija; Savelli, Luca; Weskott, Hans-Peter; Wijkstra, Hessel

    2018-04-01

    The updated version of the EFSUMB guidelines on the application of non-hepatic contrast-enhanced ultrasound (CEUS) deals with the use of microbubble ultrasound contrast outside the liver in the many established and emerging applications. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Ultrasound image-guided therapy enhances antitumor effect of cisplatin.

    PubMed

    Sasaki, Noboru; Kudo, Nobuki; Nakamura, Kensuke; Lim, Sue Yee; Murakami, Masahiro; Kumara, W R Bandula; Tamura, Yu; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2014-01-01

    The aim of this study was to clarify whether ultrasound image-guided cisplatin delivery with an intratumor microbubble injection enhances the antitumor effect in a xenograft mouse model. Canine thyroid adenocarcinoma cells were used for all experiments. Before in vivo experiments, the cisplatin and microbubble concentration and ultrasound exposure time were optimized in vitro. For in vivo experiments, cells were implanted into the back of nude mice. Observed by a diagnostic ultrasound machine, a mixture of cisplatin and ultrasound contrast agent, Sonazoid, microbubbles was injected directly into tumors. The amount of injected cisplatin and microbubbles was 1 μg/tumor and 1.2 × 10(7) microbubbles/tumor, respectively, with a total injected volume of 20 μl. Using the same diagnostic machine, tumors were exposed to ultrasound for 15 s. The treatment was repeated four times. The combination of cisplatin, microbubbles, and ultrasound significantly delayed tumor growth as compared with no treatment (after 18 days, 157 ± 55 vs. 398 ± 49 mm(3), P = 0.049). Neither cisplatin alone nor the combination of cisplatin and ultrasound delayed tumor growth. The treatment did not decrease the body weight of mice. Ultrasound image-guided anticancer drug delivery may enhance the antitumor effects of drugs without obvious side effects.

  16. Early Recovery of Aphasia through Thrombolysis: The Significance of Spontaneous Speech.

    PubMed

    Furlanis, Giovanni; Ridolfi, Mariana; Polverino, Paola; Menichelli, Alina; Caruso, Paola; Naccarato, Marcello; Sartori, Arianna; Torelli, Lucio; Pesavento, Valentina; Manganotti, Paolo

    2018-07-01

    Aphasia is one of the most devastating stroke-related consequences for social interaction and daily activities. Aphasia recovery in acute stroke depends on the degree of reperfusion after thrombolysis or thrombectomy. As aphasia assessment tests are often time-consuming for patients with acute stroke, physicians have been developing rapid and simple tests. The aim of our study is to evaluate the improvement of language functions in the earliest stage in patients treated with thrombolysis and in nontreated patients using our rapid screening test. Our study is a single-center prospective observational study conducted at the Stroke Unit of the University Medical Hospital of Trieste (January-December 2016). Patients treated with thrombolysis and nontreated patients underwent 3 aphasia assessments through our rapid screening test (at baseline, 24 hours, and 72 hours). The screening test assesses spontaneous speech, oral comprehension of words, reading aloud and comprehension of written words, oral comprehension of sentences, naming, repetition of words and a sentence, and writing words. The study included 40 patients: 18 patients treated with thrombolysis and 22 nontreated patients. Both groups improved over time. Among all language parameters, spontaneous speech was statistically significant between 24 and 72 hours (P value = .012), and between baseline and 72 hours (P value = .017). Our study demonstrates that patients treated with thrombolysis experience greater improvement in language than the nontreated patients. The difference between the 2 groups is increasingly evident over time. Moreover, spontaneous speech is the parameter marked by the greatest improvement. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  17. Intravenous thrombolysis and endovascular therapy for acute ischemic stroke with internal carotid artery occlusion: a systematic review of clinical outcomes.

    PubMed

    Mokin, Maxim; Kass-Hout, Tareq; Kass-Hout, Omar; Dumont, Travis M; Kan, Peter; Snyder, Kenneth V; Hopkins, L Nelson; Siddiqui, Adnan H; Levy, Elad I

    2012-09-01

    Strokes secondary to acute internal carotid artery (ICA) occlusion are associated with extremely poor prognosis. The best treatment approach to acute stroke in this setting is unknown. We sought to determine clinical outcomes in patients with acute ischemic stroke attributable to ICA occlusion treated with intravenous (IV) systemic thrombolysis or intra-arterial endovascular therapy. Using the PubMed database, we searched for studies that included patients with acute ischemic stroke attributable to ICA occlusion who received treatment with IV thrombolysis or intra-arterial endovascular interventions. Studies providing data on functional outcomes beyond 30 days and mortality and symptomatic intracerebral hemorrhage (sICH) rates were included in our analysis. We compared the proportions of patients with favorable functional outcomes, sICH, and mortality rates in the 2 treatment groups by calculating χ(2) and confidence intervals for odds ratios. We identified 28 studies with 385 patients in the IV thrombolysis group and 584 in the endovascular group. Rates of favorable outcomes and sICH were significantly higher in the endovascular group than the IV thrombolysis-only group (33.6% vs 24.9%, P=0.004 and 11.1% vs 4.9%, P=0.001, respectively). No significant difference in mortality rate was found between the groups (27.3% in the IV thrombolysis group vs 32.0% in the endovascular group; P=0.12). According to our systematic review, endovascular treatment of acute ICA occlusion results in improved clinical outcomes. A higher rate of sICH after endovascular treatment does not result in increased overall mortality rate.

  18. Microalgae as feedstock for biodiesel production under ultrasound treatment - A review.

    PubMed

    Sivaramakrishnan, Ramachandran; Incharoensakdi, Aran

    2018-02-01

    The application of ultrasound in biodiesel production has recently emerged as a novel technology. Ultrasound treatment enhances the mass transfer characteristics leading to the increased reaction rate with short reaction time and potentially reduces the production cost. In this review, application of ultrasound-assisted biodiesel production using acid, base and enzyme catalysts is presented. A critical assessment of the current status of ultrasound in biodiesel production was discussed with the emphasis on using ultrasound for efficient microalgae biodiesel production. The ultrasound in the biodiesel production enhances the emulsification of immiscible liquid reactant by microturbulence generated by cavitation bubbles. The major benefit of the ultrasound-assisted biodiesel production is a reduction in reaction time. Several different methods have been discussed to improve the biodiesel production. Overall, this review focuses on the current understanding of the application of ultrasound in biodiesel production from microalgae and to provide insights into future developments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Ultrasound-enhanced drug delivery for cancer.

    PubMed

    Mo, Steven; Coussios, Constantin-C; Seymour, Len; Carlisle, Robert

    2012-12-01

    Ultrasound, which has traditionally been used as a diagnostic tool, is increasingly being used in non-invasive therapy and drug delivery. Of particular interest to this review is the rapidly accumulating evidence that ultrasound may have a key role to play both in improving the targeting and the efficacy of drug delivery for cancer. Currently available ultrasound-triggerable vehicles are first described, with particular reference to the ultrasonic mechanism that can activate release and the suitability of the size range of the vehicle used for drug delivery. Further mechanical and thermal effects of ultrasound that can enhance extravasation and drug distribution following release are then critically reviewed. Acoustic cavitation is found to play a potentially key role both in achieving targeted drug release and enhanced extravasation at modest pressure amplitudes and acoustic energies, whilst simultaneously enabling real-time monitoring of the drug delivery process. The next challenge in ultrasound-enhanced drug delivery will thus be to develop a new generation of drug-carrying nanoparticles which are of the right size range for delivery to tumours, yet still capable of achieving initiation of cavitation activity and drug release at modest acoustic pressures and energies that have no safety implications for the patient.

  20. Microbubble and ultrasound radioenhancement of bladder cancer

    PubMed Central

    Tran, W T; Iradji, S; Sofroni, E; Giles, A; Eddy, D; Czarnota, G J

    2012-01-01

    Background: Tumour vasculature is an important component of tumour growth and survival. Recent evidence indicates tumour vasculature also has an important role in tumour radiation response. In this study, we investigated ultrasound and microbubbles to enhance the effects of radiation. Methods: Human bladder cancer HT-1376 xenografts in severe combined immuno-deficient mice were used. Treatments consisted of no, low and high concentrations of microbubbles and radiation doses of 0, 2 and 8 Gy in short-term and longitudinal studies. Acute response was assessed 24 h after treatment and longitudinal studies monitored tumour response weekly up to 28 days using power Doppler ultrasound imaging for a total of 9 conditions (n=90 animals). Results: Quantitative analysis of ultrasound data revealed reduced blood flow with ultrasound-microbubble treatments alone and further when combined with radiation. Tumours treated with microbubbles and radiation revealed enhanced cell death, vascular normalisation and areas of fibrosis. Longitudinal data demonstrated a reduced normalised vascular index and increased tumour cell death in both low and high microbubble concentrations with radiation. Conclusion: Our study demonstrated that ultrasound-mediated microbubble exposure can enhance radiation effects in tumours, and can lead to enhanced tumour cell death. PMID:22790798

  1. Liver haemostasis using microbubble-enhanced ultrasound at a low acoustic intensity.

    PubMed

    Zhao, Xiaochen; Li, Lu; Zhao, Hongzhi; Li, Tao; Wu, Shengzheng; Zhong, Yu; Zhao, Yang; Liu, Zheng

    2012-02-01

    To explore the haemostatic effects of microbubble-enhanced ultrasound (MEUS) at a very low acoustic intensity on the bleeding liver of rabbits. Liver incisions made on 20 rabbits were treated with a pulsed therapeutic ultrasound transducer. The transducer was operated at 831 KHz with an acoustic intensity of 0.4 W/cm(2). The treatment was coordinated with intravenous injection of microbubbles. Ultrasound only and sham treatment served as the controls. Visual bleeding score and 10-min bleeding volume were evaluated for haemostatic efficacy. Contrast-enhanced ultrasound (CEUS) was performed to assess the liver perfusion. Nine treated livers were harvested for acute histological examination. Regarding the bleeding incisions made on rabbit livers, the haemorrhage stopped immediately after 2 min of MEUS treatment but bleeding continued in the controls treated by ultrasound or microbubble injection alone. The bleeding scores and the 10-min haemorrhagic volumes dropped significantly in the MEUS group compared with those of the controls (p < 0.01). The mechanism of MEUS haemostasis appears to involve the extensive swelling of hepatocytes and the haemorrhage of the portal area, which formed a joint compression on the regional liver circulation. Low acoustic intensity MEUS might provide a novel method for liver haemostasis. • This animal experiment demonstrates a novel method of controlling hepatic haemorrhage • The treatment uses therapeutic ultrasound during enhancement with intravenous microbubbles • This combined therapy was more effective than ultrasound or intravenous microbubbles alone • More work is required with larger animals before potential human trials.

  2. Ultrasound in Space Medicine

    NASA Technical Reports Server (NTRS)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  3. Impact of Focused Ultrasound-enhanced Drug Delivery on Survival in Rats with Glioma

    NASA Astrophysics Data System (ADS)

    Treat, Lisa Hsu; Zhang, Yongzhi; McDannold, Nathan; Hynynen, Kullervo

    2009-04-01

    Malignancies of the brain remain difficult to treat with chemotherapy because the selective permeability of the blood-brain barrier (BBB) blocks many potent agents from reaching their target. Previous studies have illustrated the feasibility of drug and antibody delivery across the BBB using MRI-guided focused ultrasound. In this study, we investigated the impact of focused ultrasound-enhanced delivery of doxorubicin on survival in rats with aggressive glioma. Sprague-Dawley rats were implanted with 9 L gliosarcoma cells in the brain. Eight days after implantation, each rat received one of the following: (1) no treatment (control), (2) a single treatment with microbubble-enhanced MRI-guided focused ultrasound (FUS only), (3) a single treatment with i.v. liposomal doxorubicin (DOX only), or (4) a single treatment with microbubble-enhanced MRI-guided focused ultrasound and concurrent i.v. injections of liposomal doxorubicin (FUS+DOX). The survival time from implantation to death or euthanasia was recorded. We observed a modest but significant increase in median survival time in rats treated with combined MRI-guided focused ultrasound chemotherapy, compared to chemotherapy alone (p<0.001). There was no significant improvement in survival between those who received stand-alone chemotherapy and those who did not receive any treatment (p>0.10). Our study demonstrates for the first time a therapeutic benefit achieved with ultrasound-enhanced drug delivery across the blood-brain barrier. This confirmation of efficacy in an in vivo tumor model indicates that targeted drug delivery using MRI-guided focused ultrasound has the potential to have a major impact on the treatment of patients with brain tumors and other neurological disorders.

  4. [The percutaneous action of a heparin-allantoin-dexpanthenol combination in a specific ointment base. Thrombolytic action on the rabbit ear].

    PubMed

    Tauschel, H D; Bonacina, F; Galetti, F

    1984-01-01

    Experimentally induced thrombi of ear veins in albino rabbits have been treated locally with heparin-containing ointments in presence or absence of allantoin and dexpanthenol, the heparin concentration varying. While the ointments, containing heparin only, induce no or only minor thrombolytic activity, the combination ointments Hepathrombin Adenylchemie containing heparin, allantoin and dexpanthenol show significant thrombolytic activity. This effect is dependent upon the heparin concentration, yet, heparin doses above 50 000 IU per 100 g of ointment do not enhance the thrombolysis furthermore. Further, the studies show that the effective components of Hepathrombin do penetrate into and through the skin, allantoin and dexpanthenol being important components of the ointment probably supporting the transdermal penetration of heparin. The studies also demonstrate the only local thrombolytic effect of the Hepathrombin ointments because the thrombus of the right ear, always treated with ointment base only, did not show any change in length as contrasted to that of the left ear of the same animal treated with the Hepathrombin ointments. Mechanisms of the locally by Hepathrombin/heparin induced thrombolysis will be discussed.

  5. Bas-relief map using texture analysis with application to live enhancement of ultrasound images.

    PubMed

    Du, Huarui; Ma, Rui; Wang, Xiaoying; Zhang, Jue; Fang, Jing

    2015-05-01

    For ultrasound imaging, speckle is one of the most important factors in the degradation of contrast resolution because it masks meaningful texture and has the potential to interfere with diagnosis. It is expected that researchers would explore appropriate ways to reduce the speckle noise, to find the edges of structures and enhance weak borders between different organs in ultrasound imaging. Inspired by the principle of differential interference contrast microscopy, a "bas-relief map" is proposed that depicts the texture structure of ultrasound images. Based on a bas-relief map, an adaptive bas-relief filter was developed for ultrafast despeckling. Subsequently, an edge map was introduced to enhance the edges of images in real time. The holistic bas-relief map approach has been used experimentally with synthetic phantoms and digital ultrasound B-scan images of liver, kidney and gallbladder. Based on the visual inspection and the performance metrics of the despeckled images, it was found that the bas-relief map approach is capable of effectively reducing the speckle while significantly enhancing contrast and tissue boundaries for ultrasonic images, and its speckle reduction ability is comparable to that of Kuan, Lee and Frost filters. Meanwhile, the proposed technique could preserve more intra-region details compared with the popular speckle reducing anisotropic diffusion technique and more effectively enhance edges. In addition, the adaptive bas-relief filter was much less time consuming than the Kuan, Lee and Frost filter and speckle reducing anisotropic diffusion techniques. The bas-relief map strategy is effective for speckle reduction and live enhancement of ultrasound images, and can provide a valuable tool for clinical diagnosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Quantitative assessment of placental perfusion by contrast-enhanced ultrasound in macaques and human subjects

    PubMed Central

    Roberts, Victoria HJ; Lo, Jamie O; Salati, Jennifer A; Lewandowski, Katherine S; Lindner, Jonathan R; Morgan, Terry K; Frias, Antonio E

    2016-01-01

    Background The utero-placental vascular supply is a critical determinant of placental function and fetal growth. Current methods for the in vivo assessment of placental blood flow are limited. Objective Here we demonstrate the feasibility of utilizing contrast-enhanced ultrasound to visualize and quantify perfusion kinetics in the intervillous space of the primate placenta. Study design Pregnant Japanese macaques were studied at mid second trimester and in the early third trimester. Markers of injury were assessed in placenta samples from animals with or without contrast-enhanced ultrasound exposure (n=6/group). Human subjects were recruited immediately prior to scheduled first trimester pregnancy termination. All studies were performed with maternal intravenous infusion of lipid-shelled octofluoropropane microbubbles with image acquisition using a multipulse contrast-specific algorithm with destruction-replenishment analysis of signal intensity for assessment of perfusion. Results In macaques, rate of perfusion in the intervillous space was increased with advancing gestation. No evidence of microvascular hemorrhage or acute inflammation was found in placental villous tissue and expression levels of caspase-3, nitrotyrosine and HSP70 as markers of apoptosis, nitrative and oxidative stress respectively were unchanged by contrast-enhanced ultrasound exposure. In humans, placental perfusion was visualized at 11wks gestation and preliminary data reveal regional differences in intervillous space perfusion within an individual placenta. By electron microscopy, we demonstrate no evidence of ultrastructure damage to the microvilli on the syncytiotrophoblast following first trimester ultrasound studies. Conclusions Use of contrast-enhanced ultrasound did not result in placental structural damage, and was able to identify intervillous space perfusion rate differences within a placenta. Contrast-enhanced ultrasound may offer a safe clinical tool for the identification of pregnancies at-risk for vascular insufficiency; early recognition may facilitate intervention and improved pregnancy outcomes. PMID:26928151

  7. Ultrasound-enhanced delivery of targeted echogenic liposomes in a novel ex vivo mouse aorta model.

    PubMed

    Hitchcock, Kathryn E; Caudell, Danielle N; Sutton, Jonathan T; Klegerman, Melvin E; Vela, Deborah; Pyne-Geithman, Gail J; Abruzzo, Todd; Cyr, Peppar E P; Geng, Yong-Jian; McPherson, David D; Holland, Christy K

    2010-06-15

    The goal of this study was to determine whether targeted, Rhodamine-labeled echogenic liposomes (Rh-ELIP) containing nanobubbles could be delivered to the arterial wall, and whether 1-MHz continuous wave ultrasound would enhance this delivery profile. Aortae excised from apolipoprotein-E-deficient (n=8) and wild-type (n=8) mice were mounted in a pulsatile flow system through which Rh-ELIP were delivered in a stream of bovine serum albumin. Half the aortae from each group were treated with 1-MHz continuous wave ultrasound at 0.49 MPa peak-to-peak pressure, and half underwent sham exposure. Ultrasound parameters were chosen to promote stable cavitation and avoid inertial cavitation. A broadband hydrophone was used to monitor cavitation activity. After treatment, aortic sections were prepared for histology and analyzed by an individual blinded to treatment conditions. Delivery of Rh-ELIP to the vascular endothelium was observed, and sub-endothelial penetration of Rh-ELIP was present in five of five ultrasound-treated aortae and was absent in those not exposed to ultrasound. However, the degree of penetration in the ultrasound-exposed aortae was variable. There was no evidence of ultrasound-mediated tissue damage in any specimen. Ultrasound-enhanced delivery within the arterial wall was demonstrated in this novel model, which allows quantitative evaluation of therapeutic delivery. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  8. Contrast-enhanced ultrasound evaluation of pancreatic cancer xenografts in nude mice after irradiation with sub-threshold focused ultrasound for tumor ablation

    PubMed Central

    Wang, Rui; Guo, Qian; Chen, Yi Ni; Hu, Bing; Jiang, Li Xin

    2017-01-01

    We evaluated the efficacy of contrast-enhanced ultrasound for assessing tumors after irradiation with sub-threshold focused ultrasound (FUS) ablation in pancreatic cancer xenografts in nude mice. Thirty tumor-bearing nude mice were divided into three groups: Group A received sham irradiation, Group B received a moderate-acoustic energy dose (sub-threshold), and Group C received a high-acoustic energy dose. In Group B, B-mode ultrasound (US), color Doppler US, and dynamic contrast-enhanced ultrasound (DCE-US) studies were conducted before and after irradiation. After irradiation, tumor growth was inhibited in Group B, and the tumors shrank in Group C. In Group A, the tumor sizes were unchanged. In Group B, contrast-enhanced ultrasound (CEUS) images showed a rapid rush of contrast agent into and out of tumors before irradiation. After irradiation, CEUS revealed contrast agent perfusion only at the tumor periphery and irregular, un-perfused volumes of contrast agent within the tumors. DCE-US perfusion parameters, including peak intensity (PI) and area under the curve (AUC), had decreased 24 hours after irradiation. PI and AUC were increased 48 hours and 2weeks after irradiation. Time to peak (TP) and sharpness were increased 24 hours after irradiation. TP decreased at 48 hours and 2 weeks after irradiation. CEUS is thus an effective method for early evaluation after irradiation with sub-threshold FUS. PMID:28402267

  9. Investigating the sonophoresis effect on the permeation of diclofenac sodium using 3D skin equivalent.

    PubMed

    Aldwaikat, Mai; Alarjah, Mohammed

    2015-01-01

    Ultrasound temporally increases skin permeability by altering stratum corneum SC function (sonophoresis). The objective of this study was to evaluate the effect of variable ultrasound conditions on the permeation of diclofenac sodium DS with range of physicochemical properties through EpiDerm™. Permeation studies were carried out in vitro using Franz diffusion cell. HPLC method was used for the determination of the concentration of diclofenac sodium in receiving compartment. Parameters like ultrasound frequency, application time, amplitude, and mode of sonication and distance of ultrasound horn from skin were investigated, and the conditions where the maximum enhancement rate obtained were determined. Application of ultrasound enhanced permeation of diclofenac sodium across EpiDerm™ by fivefolds. The most effective enhancing parameters were power sonication of 20kHz frequency, 20% amplitude at continuous mode for 5min. Copyright © 2014. Published by Elsevier B.V.

  10. Ceramic membrane ultrafiltration of natural surface water with ultrasound enhanced backwashing.

    PubMed

    Boley, A; Narasimhan, K; Kieninger, M; Müller, W-R

    2010-01-01

    Ultrafiltration membrane cleaning with ultrasound enhanced backwashing was investigated with two ceramic membrane systems in parallel. One of them was subjected to ultrasound during backwashing, the other acted as a reference system. The feed water was directly taken from a creek with a sedimentation process as only pre-treatment. The cleaning performance was improved with ultrasound but after 3 weeks of operation damages occurred on the membranes. These effects were studied with online measurements of flux, trans-membrane-pressure and temperature, but also with integrity tests, turbidity measurements and visual examination.

  11. Mechanistic insight into ultrasound induced enhancement of simultaneous saccharification and fermentation of Parthenium hysterophorus for ethanol production.

    PubMed

    Singh, Shuchi; Agarwal, Mayank; Sarma, Shyamali; Goyal, Arun; Moholkar, Vijayanand S

    2015-09-01

    This paper presents investigations into mechanism of ultrasound assisted bioethanol synthesis using Parthenium hysterophorus biomass through simultaneous saccharification and fermentation (SSF) mode. Approach of coupling experimental results to mathematical model for SSF using Genetic Algorithm based optimization has been adopted. Comparison of model parameters for experiments with mechanical shaking and sonication (10% duty cycle) give an interesting mechanistic account of influence of ultrasound on SSF system. A 4-fold rise in ethanol and cell mass productivity is seen with ultrasound. The analysis reveals following facets of influence of ultrasound on SSF: increase in Monod constant for glucose for cell growth, maximal specific growth rate and inhibition constant of cell growth by glucose and reduction in specific cell death rate. Values of inhibition constant of cell growth by ethanol (K3E), and constants for growth associated (a) and non-growth associated (b) ethanol production remained unaltered with sonication. Beneficial effects of ultrasound are attributed to enhanced cellulose hydrolysis, enhanced trans-membrane transport of substrate and products as well as dilution of the toxic substances due to micro-convection induced by ultrasound. Intrinsic physiological functioning of cells remained unaffected by ultrasound as indicated by unaltered values of K3E, a and b. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Patient Selection for Drip and Ship Thrombolysis in Acute Ischemic Stroke

    PubMed Central

    Lyerly, Michael J.; Albright, Karen C.; Boehme, Amelia K.; Shahripour, Reza Bavarsad; Donnelly, John P.; Houston, James T.; Rawal, Pawan V.; Kapoor, Niren; Alvi, Muhammad; Sisson, April; Alexandrov, Anne W.; Alexandrov, Andrei V.

    2017-01-01

    Objectives The drip and ship model is a method used to deliver thrombolysis to acute stroke patients in facilities lacking onsite neurology coverage. We sought to determine whether our drip and ship population differs from patients treated directly at our stroke center (direct presenters). Methods We retrospectively reviewed consecutive patients who received thrombolysis at an outside facility with subsequent transfer to our center between 2009 and 2011. Patients received thrombolysis after telephone consultation with a stroke specialist. We examined demographics, vascular risk factors, laboratory values, and stroke severity in drip and ship patients compared with direct presenters. Results Ninety-six patients were identified who received thrombolysis by drip and ship compared with 212 direct presenters. The two groups did not differ with respect to sex, ethnicity, vascular risk factors, or admission glucose. The odds ratio (OR) of arriving at our hospital as a drip and ship for someone 80 years or older was 0.31 (95% confidence interval [CI] 0.15–0.61, P < 0.001). Only 21% of drip and ship patients were black versus 38% of direct presenters (OR 0.434, 95% CI 0.25–0.76, P = 0.004). Even after stratifying by age (<80 vs ≥80), a smaller proportion of drip and ship patients were black (OR 0.44, 95% CI 0.24–0.81, P = 0.008). Furthermore, we found that fewer black patients with severe strokes arrived by drip and ship (OR 0.33, 95% CI 0.11–0.98, P = 0.0028). Conclusions Our study showed that a smaller proportion of blacks and older adults arrived at our center by the drip and ship model. This may reflect differences in how patients are selected for thrombolysis and transfer to a higher level of care. PMID:26192934

  13. Patient Selection for Drip and Ship Thrombolysis in Acute Ischemic Stroke.

    PubMed

    Lyerly, Michael J; Albright, Karen C; Boehme, Amelia K; Shahripour, Reza Bavarsad; Donnelly, John P; Houston, James T; Rawal, Pawan V; Kapoor, Niren; Alvi, Muhammad; Sisson, April; Alexandrov, Anne W; Alexandrov, Andrei V

    2015-07-01

    The drip and ship model is a method used to deliver thrombolysis to acute stroke patients in facilities lacking onsite neurology coverage. We sought to determine whether our drip and ship population differs from patients treated directly at our stroke center (direct presenters). We retrospectively reviewed consecutive patients who received thrombolysis at an outside facility with subsequent transfer to our center between 2009 and 2011. Patients received thrombolysis after telephone consultation with a stroke specialist. We examined demographics, vascular risk factors, laboratory values, and stroke severity in drip and ship patients compared with direct presenters. Ninety-six patients were identified who received thrombolysis by drip and ship compared with 212 direct presenters. The two groups did not differ with respect to sex, ethnicity, vascular risk factors, or admission glucose. The odds ratio (OR) of arriving at our hospital as a drip and ship for someone 80 years or older was 0.31 (95% confidence interval [CI] 0.15-0.61, P < 0.001). Only 21% of drip and ship patients were black versus 38% of direct presenters (OR 0.434, 95% CI 0.25-0.76, P = 0.004). Even after stratifying by age (<80 vs ≥80), a smaller proportion of drip and ship patients were black (OR 0.44, 95% CI 0.24-0.81, P = 0.008). Furthermore, we found that fewer black patients with severe strokes arrived by drip and ship (OR 0.33, 95% CI 0.11-0.98, P = 0.0028). Our study showed that a smaller proportion of blacks and older adults arrived at our center by the drip and ship model. This may reflect differences in how patients are selected for thrombolysis and transfer to a higher level of care.

  14. Do lacunar strokes benefit from thrombolysis? Evidence from the Registry of the Canadian Stroke Network.

    PubMed

    Shobha, Nandavar; Fang, Jiming; Hill, Michael D

    2013-10-01

    Lacunar infarcts constitute up to 25% of all ischaemic strokes. As acute intracranial vascular imaging has become widely available with computed tomographic angiography, thrombolysis of lacunar strokes has become contentious because an intracranial vascular lesion cannot be visualized. We studied the effect of thrombolysis on lacunar strokes compared to other clinical ischaemic stroke sub-types. Ischaemic stroke patients from phase 3 of the Registry of the Canadian Stroke Network data (July 2003-March 2008) were included. Lacunar stroke was defined as a lacunar syndrome supported by computed tomography brain showing a subcortical hypodense lesion with a diameter <20 mm. Clinical syndromes were used to define other stroke sub-types. The outcomes were mortality at 90 days, modified Rankin Scale score 0-2 at discharge, occurrence of intracranial haemorrhage as a complication of stroke in-hospital, and discharge disposition to home. A total of 11,503 patients of ischaemic stroke were included from the Registry of the Canadian Stroke Network 3 between July 2003 and March 2008. Lacunar strokes formed 19.1% of the total strokes. The total number of patients who received tissue plasminogen activator was 1630 (14.2%). A significant association was found between tissue plasminogen activator treatment and outcomes after controlling Oxfordshire Community Stroke Project types--for modified Rankin Scale at discharge and discharge to home, but not for mortality. A thrombolysis-by-Oxfordshire Community Stroke Project stroke sub-type interaction was observed due to lack of benefit among the posterior circulation stroke sub-types. Patients with lacunar strokes, partial anterior circulation stroke, and total anterior circulation strokes all benefited approximately equally from thrombolysis. Thrombolysis is associated with clinically improved outcome among patients with lacunar stroke syndromes. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.

  15. Development of a Cancer Treatment with the Concomitant Use of Low-Intensity Ultrasound: Entering the Age of Simultaneous Diagnosis and Treatment

    PubMed Central

    Emoto, Makoto

    2014-01-01

    In recent years, studies using ultrasound energy for cancer treatment have advanced, thus revealing the enhancement of drug effects by employing low-intensity ultrasound. Furthermore, anti-angiogenesis against tumors is now attracting attention as a new cancer treatment. Therefore, we focused on the biological effects and the enhancement of drug effects brought by this low-intensity ultrasound energy and reported on the efficacy against a uterine sarcoma model, by implementing the basic studies, for the first time, including the concomitant use of low-intensity ultrasound irradiation, as an expected new antiangiogenic therapy for cancer treatment. Furthermore, we have succeeded in simultaneously utilizing low-intensity ultrasound in both diagnosis and treatment, upon real time evaluation of the anti-tumor effects and anti-angiogenesis effects using color Doppler ultrasound imaging. Although the biological effects of ultrasound have not yet been completely clarified, transient stomas were formed (Sonoporation) in cancer cells irradiated by low-intensity ultrasound and it is believed that the penetration effect of drugs is enhanced due to the drug being more charged inside the cell through these stomas. Furthermore, it has become clear that the concomitant therapy of anti-angiogenesis drugs and low-intensity ultrasound blocks the angiogenic factor VEGF produced by cancer cells, inhibits the induction of circulating endothelial progenitor cells in the bone marrow, and expedites angiogenic inhibitor TSP-1. Based on research achievements in recent years, we predict that the current diagnostic device for color Doppler ultrasound imaging will be improved in the near future, bringing with it the arrival of an age of “low-intensity ultrasound treatment that simultaneously enables diagnosis and treatment of cancer in real time.” PMID:26852677

  16. Diagnostic instrumentation aboard ISS: just-in-time training for non-physician crewmembers.

    PubMed

    Foale, C Michael; Kaleri, Alexander Y; Sargsyan, Ashot E; Hamilton, Douglas R; Melton, Shannon; Martin, David; Dulchavsky, Scott A

    2005-06-01

    The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed "just-in-time" training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This "just-in-time" concept was used to support real-time remote expert guidance to complete ultrasound examinations using the ISS Human Research Facility (HRF). An American and Russian ISS crewmember received 2 h of "hands on" ultrasound training 8 mo prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember 6 d prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. Results of the CD-ROM-based OPE session were used to modify the instructions during a complete 35-min real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were adequate for clinical decision making. Complex ultrasound experiments with expert guidance were performed with high accuracy following limited preflight training and multimedia based in-flight review, despite a 2-s communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, facilitates the successful performance of ultrasound examinations on orbit and may have additional terrestrial and space applications.

  17. Diagnostic instrumentation aboard ISS: just-in-time training for non-physician crewmembers

    NASA Technical Reports Server (NTRS)

    Foale, C. Michael; Kaleri, Alexander Y.; Sargsyan, Ashot E.; Hamilton, Douglas R.; Melton, Shannon; Martin, David; Dulchavsky, Scott A.

    2005-01-01

    INTRODUCTION: The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed "just-in-time" training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This "just-in-time" concept was used to support real-time remote expert guidance to complete ultrasound examinations using the ISS Human Research Facility (HRF). METHODS: An American and Russian ISS crewmember received 2 h of "hands on" ultrasound training 8 mo prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember 6 d prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. RESULTS: Results of the CD-ROM-based OPE session were used to modify the instructions during a complete 35-min real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were adequate for clinical decision making. CONCLUSIONS: Complex ultrasound experiments with expert guidance were performed with high accuracy following limited preflight training and multimedia based in-flight review, despite a 2-s communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, facilitates the successful performance of ultrasound examinations on orbit and may have additional terrestrial and space applications.

  18. Tissue mimicking simulations for temporal enhanced ultrasound-based tissue typing

    NASA Astrophysics Data System (ADS)

    Bayat, Sharareh; Imani, Farhad; Gerardo, Carlos D.; Nir, Guy; Azizi, Shekoofeh; Yan, Pingkun; Tahmasebi, Amir; Wilson, Storey; Iczkowski, Kenneth A.; Lucia, M. Scott; Goldenberg, Larry; Salcudean, Septimiu E.; Mousavi, Parvin; Abolmaesumi, Purang

    2017-03-01

    Temporal enhanced ultrasound (TeUS) is an imaging approach where a sequence of temporal ultrasound data is acquired and analyzed for tissue typing. Previously, in a series of in vivo and ex vivo studies we have demonstrated that, this approach is effective for detecting prostate and breast cancers. Evidences derived from our experiments suggest that both ultrasound-signal related factors such as induced heat and tissue-related factors such as the distribution and micro-vibration of scatterers lead to tissue typing information in TeUS. In this work, we simulate mechanical micro-vibrations of scatterers in tissue-mimicking phantoms that have various scatterer densities reflecting benign and cancerous tissue structures. Finite element modeling (FEM) is used for this purpose where the vertexes are scatterers representing cell nuclei. The initial positions of scatterers are determined by the distribution of nuclei segmented from actual digital histology scans of prostate cancer patients. Subsequently, we generate ultrasound images of the simulated tissue structure using the Field II package resulting in a temporal enhanced ultrasound. We demonstrate that the micro-vibrations of scatterers are captured by temporal ultrasound data and this information can be exploited for tissue typing.

  19. [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

    PubMed

    Jung, E M; Clevert, D A

    2018-06-01

    Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.

  20. Frequency sensitive mechanism in low-intensity ultrasound enhanced bioeffects

    PubMed Central

    Chama, Abdoulkadri; Subramanian, Anuradha; Viljoen, Hendrik J.

    2017-01-01

    This study presents two novel theoretical models to elucidate frequency sensitive nuclear mechanisms in low-intensity ultrasound enhanced bioeffects. In contrast to the typical 1.5 MHz pulsed ultrasound regime, our group previously experimentally confirmed that ultrasound stimulation of anchored chondrocytes at resonant frequency maximized gene expression of load inducible genes which are regulatory markers for cellular response to external stimuli. However, ERK phosphorylation displayed no frequency dependency, suggesting that the biochemical mechanisms involved in enhanced gene expression is downstream of ERK phosphorylation. To elucidate such underlying mechanisms, this study presents a theoretical model of an anchored cell, representing an in vitro chondrocyte, in an ultrasound field. The model results showed that the mechanical energy storage is maximized at the chondrocyte’s resonant frequency and the energy density in the nucleus is almost twice as high as in the cytoplasm. Next, a mechanochemical model was developed to link the mechanical stimulation of ultrasound and the increased mechanical energy density in the nucleus to the downstream targets of the ERK pathway. This study showed for the first time that ultrasound stimulation induces frequency dependent gene expression as a result of altered rates of transcription factors binding to chromatin. PMID:28763448

  1. Nanoparticle Delivery Enhancement With Acoustically Activated Microbubbles

    PubMed Central

    Mullin, Lee B; Phillips, Linsey C; Dayton, Paul A

    2013-01-01

    The application of microbubbles and ultrasound to deliver nanoparticle carriers for drug and gene delivery is an area that has expanded greatly in recent years. Under ultrasound exposure, microbubbles can enhance nanoparticle delivery by increasing cellular and vascular permeability. In this review, the underlying mechanisms of enhanced nanoparticle delivery with ultrasound and microbubbles and various proposed delivery techniques are discussed. Additionally, types of nanoparticles currently being investigated in preclinical studies, as well as the general limitations and benefits of a microbubble-based approach to nanoparticle delivery are reviewed. PMID:23287914

  2. Thrombolysis in the age of Primary Percutaneous Coronary Intervention: Mini-Review and Meta-analysis of Early PCI.

    PubMed

    Al Shammeri, O; Garcia, LA

    2013-01-01

    Primary Percutaneous Coronary Intervention (PCI) is the treatment of choice for ST-segment Elevation Myocardial Infarction (STEMI) if performed within 90 minutes from first medical contact. However, primary PCI is only available for less than 25% of patients with STEMI. Early PCI or Pharmaco-invasive strategy has evolved from facilitated PCI but with more delayed timing from thrombolysis to PCI. Assess the safety and effectiveness of Early PCI. We reviewed the data of the available therapy options for patients with STEMI. Then we performed a meta-analysis for all randomized controlled trials of early PCI versus standard therapy. Five studies fulfilled our inclusion criteria. Our meta-analysis showed improved cardiovascular events with early PCI compared to standard therapy (odd ratio of 0.54; 95% Confidence interval 0.47-0.7, p<0.001). There were no significant bleeding complications when doing early PCI 4 to 24 hours after successful thrombolysis. Early PCI should be done to all STEMI patients within 24 hours after successful thrombolysis.

  3. Thrombolysis based on magnetically-controlled surface-functionalized Fe3O4 nanoparticle

    PubMed Central

    Chang, Ming; Lin, Yu-Hao; Gabayno, Jacque Lynn; Li, Qian; Liu, Xiaojun

    2017-01-01

    ABSTRACT In this study, the control of magnetic fields to manipulate surface-functionalized Fe3O4 nanoparticles by urokinase coating is investigated for thrombolysis in a microfluidic channel. The urokinase-coated Fe3O4 nanoparticles are characterized using particle size distribution, zeta potential measurement and spectroscopic data. Thrombolytic ratio tests reveal that the efficiency for thrombus cleaning is significantly improved when using magnetically-controlled urokinase-coated Fe3O4 nanoparticles than pure urokinase solution. The average increase in the rate of thrombolysis with the use of urokinase-coated Fe3O4 nanoparticles is about 50%. In vitro thrombolysis test in a microfluidic channel using the coated nanoparticles shows nearly complete removal of thrombus, a result that can be attributed to the clot busting effect of the urokinase as it inhibits the possible formation of blood bolus during the magnetically-activated microablation process. The experiment further demonstrates that a thrombus mass of 10.32 mg in the microchannel is fully removed in about 180 s. PMID:27689864

  4. Hyperbaric oxygen increases tissue-plasminogen activator-induced thrombolysis in vitro, and reduces ischemic brain damage and edema in rats subjected to thromboembolic brain ischemia.

    PubMed

    Chazalviel, Laurent; Haelewyn, Benoit; Degoulet, Mickael; Blatteau, Jean-Eric; Vallée, Nicolas; Risso, Jean-Jacques; Besnard, Stéphane; Abraini, Jacques H

    2016-01-01

    Recent data have shown that normobaric oxygen (NBO) increases the catalytic and thrombolytic efficiency of recombinant tissue plasminogen activator (rtPA) in vitro , and is as efficient as rtPA at restoring cerebral blood flow in rats subjected to thromboembolic brain ischemia. Therefore, in the present study, we studied the effects of hyperbaric oxygen (HBO) (i) on rtPA-induced thrombolysis in vitro and (ii) in rats subjected to thromboembolic middle cerebral artery occlusion-induced brain ischemia. HBO increases rtPA-induced thrombolysis in vitro to a greater extent than NBO; in addition, HBO treatment of 5-minute duration, but not of 25-minute duration, reduces brain damage and edema in vivo . In line with the facilitating effect of NBO on cerebral blood flow, our findings suggest that 5-minute HBO could have provided neuroprotection by promoting thrombolysis. The lack of effect of HBO exposure of longer duration is discussed.

  5. Is It Worthwhile Treating Occluded Cold Stored Venous Allografts by Thrombolysis?

    PubMed

    Balaz, P; Wohlfahrt, P; Rokosny, S; Maly, S; Bjorck, M

    2016-09-01

    Thrombolysis has been reported to be suboptimal in occluded vein grafts and cryopreserved allografts, and there are no data on the efficacy of thrombolysis in occluded cold stored venous allografts. The aim was to evaluate early outcomes, secondary patency and limb salvage rates of thrombolysed cold stored venous allograft bypasses and to compare the outcomes with thrombolysis of autologous bypasses. This was a single center study of consecutive patients with acute and non-acute limb ischemia between September 1, 2000, and January 1, 2014, with occlusion of cold stored venous allografts, and between January 1, 2012, and January 1, 2014, with occlusion of autologous bypass who received intra-arterial thrombolytic therapy. Sixty-one patients with occlusion of an infrainguinal bypass using a cold stored venous allograft (n = 35) or an autologous bypass (n = 26) underwent percutaneous intra-arterial thrombolytic therapy. The median duration of thrombolysis was 20 h (IQR 18-24) with no difference between the groups (p = .14). The median follow up was 18.5 months (IQR 11.0-52.0). Secondary patency rates of thrombolysed bypass at 6 and 12 months were 44 ± 9% and 32 ± 9% in patients with a venous allograft bypass and 46 ± 10% and 22 ± 8% with an autologous bypass, with no difference between groups (p = .40). Limb salvage rates at 1, 6, and 12 months after thrombolysis in the venous allograft group were 83 ± 7%, 72 ± 8% and 63 ± 9%, and in the autologous group 91 ± 6%, 76 ± 9%, and 65 ± 13%, with no difference between groups (p = .69). Long-term results of thrombolysis of venous allograft bypasses are similar to those of autologous bypasses. Occluded cold stored venous allograft can be successfully re-opened in most cases with a favorable effect on limb salvage. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Can the Contrast-Enhanced Ultrasound Washout Rate Be Used to Predict Microvascular Invasion in Hepatocellular Carcinoma?

    PubMed

    Zhu, Wei; Qing, Xiachuan; Yan, Feng; Luo, Yan; Li, Yongzhong; Zhou, Xiang

    2017-08-01

    The objective of this study was to investigate use of the washout rate of hepatocellular carcinoma on contrast-enhanced ultrasound (CEUS) for pre-operative determination of the presence of microvascular invasion. The study included 271 patients who underwent liver resection for hepatocellular carcinoma between April 2008 and December 2012, and were examined with contrast-enhanced ultrasound before surgery. Patients were followed up at 3-mo intervals for 3 y. Four washout patterns were classified according to the start time of washout: rapid, portal, delayed and slow. Rapid washout, presence of two or more tumors and tumor size ≥5 cm were identified as independent pre-operative predictors of microvascular invasion on multivariate analysis. Recurrence rates for patients with none, one, two or three predictors were 22.6%, 34.7%, 57.6% and 75.0%, respectively. In combination with tumor number and tumor size, contrast-enhanced ultrasound washout rate may have a role in identifying hepatocellular carcinoma patients with microvascular invasion. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. Fluorescein permeability and electrical resistance of human skin during low frequency ultrasound application.

    PubMed

    Cancel, Limary M; Tarbell, John M; Ben-Jebria, Abdellaziz

    2004-09-01

    Transdermal drug delivery offers an alternative to injections and oral medication but is limited by the low skin permeability of most drugs. The use of low-frequency ultrasound over long periods of time, typically over an hour, has been shown to enhance skin permeability, a phenomenon referred to as sonophoresis. In this study, we investigated the effects of short time sonication of human skin at 20 kHz and at variable intensities and duty cycles on the dynamics of fluorescein transport across the skin (permeability) as well as the changes in the skin's structural integrity (electrical resistance). We found that a short application of ultrasound enhanced the transport of fluorescein across human skin by a factor in the range of 2-9 for full thickness skin samples and by a factor in the range of 2-28 000 for heat-stripped stratum corneum samples (however, samples with very high (10(3)) enhancement were likely to have been damaged by ultrasound). The electrical resistance of the skin decreased by an average of 20% for full thickness samples and 58% for stratum corneum samples. Increasing the duty cycle from 10 to 60% caused a significant increase in permeability enhancement from 2.3 to 9.1, and an increase in intensity from 8 to 23 mW cm(-2) induced a significant increase in permeability enhancement from 2 to 7.4, indicating a clear dependence of the permeability on both duty cycle and intensity. The increase in solute flux upon ultrasound exposure was immediate, demonstrating for the first time the fast response dynamics of sonophoretic enhancement. In addition, a quantitative analysis of the thermal and convective dispersion effects associated with ultrasound application showed that each contributes significantly to the overall permeability enhancement observed.

  8. Intravenous thrombolysis guided by a telemedicine consultation system for acute ischaemic stroke patients in China: the protocol of a multicentre historically controlled study

    PubMed Central

    Yuan, Ziwen; Wang, Bo; Li, Feijiang; Wang, Jing; Zhi, Jin; Luo, Erping; Liu, Zhirong; Zhao, Gang

    2015-01-01

    Introduction The rate of intravenous thrombolysis with tissue-type plasminogen activator or urokinase for stroke patients is extremely low in China. It has been demonstrated that a telestroke service may help to increase the rate of intravenous thrombolysis and improve stroke care quality in local hospitals. The aim of this study, also called the Acute Stroke Advancing Program, is to evaluate the effectiveness and safety of decision-making concerning intravenous thrombolysis via a telemedicine consultation system for acute ischaemic stroke patients in China. Methods and analysis This is a multicentre historically controlled study with a planned enrolment of 300 participants in each of two groups. The telestroke network consists of one hub hospital and 14 spoke hospitals in underserved regions of China. The usual stroke care quality in the spoke hospitals without guidance from the hub hospital will be used as the historical control. The telemedicine consultation system is an interactive, two-way, wireless, audiovisual system accessed on portable devices. The primary outcome is the percentage of patients treated with intravenous thrombolysis within 4.5 h of stroke onset. Ethics and dissemination The project has been approved by the Institutional Review Board of Xijing Hospital. The results will be published in scientific journals and presented to local government and relevant institutes. Trial registration number NCT02088346 (12 March 2014). PMID:25979867

  9. Single-transducer dual-frequency ultrasound generation to enhance acoustic cavitation.

    PubMed

    Liu, Hao-Li; Hsieh, Chao-Ming

    2009-03-01

    Dual- or multiple-frequency ultrasound stimulation is capable of effectively enhancing the acoustic cavitation effect over single-frequency ultrasound. Potential application of this sonoreactor design has been widely proposed such as on sonoluminescence, sonochemistry enhancement, and transdermal drug release enhancement. All currently available sonoreactor designs employed multiple piezoelectric transducers for generating single-frequency ultrasonic waves separately and then these waves were mixed and interfered in solutions. The purpose of this research is to propose a novel design of generating dual-frequency ultrasonic waves with single piezoelectric elements, thereby enhancing acoustic cavitation. Macroscopic bubbles were detected optically, and they were quantified at either a single-frequency or for different frequency combinations for determining their efficiency for enhancing acoustic cavitation. Visible bubbles were optically detected and hydrogen peroxide was measured to quantify acoustic cavitation. Test water samples with different gas concentrations and different power levels were used to determine the efficacy of enhancing acoustic cavitation of this design. The spectrum obtained from the backscattered signals was also recorded and examined to confirm the occurrence of stable cavitation. The results confirmed that single-element dual-frequency ultrasound stimulation can enhance acoustic cavitation. Under certain testing conditions, the generation of bubbles can be enhanced up to a level of five times higher than the generation of bubbles in single-frequency stimulation, and can increase the hydrogen peroxide production up to an increase of one fold. This design may serve as a useful alternative for future sonoreactor design owing to its simplicity to produce dual- or multiple-frequency ultrasound.

  10. Multicenter, dose-ranging study of efegatran sulfate versus heparin with thrombolysis for acute myocardial infarction: The Promotion of Reperfusion in Myocardial Infarction Evolution (PRIME) trial.

    PubMed

    2002-01-01

    Adjunctive therapies that increase the incidence of normal reperfusion after thrombolysis for acute myocardial infarction (MI) could enhance clinical outcomes. Direct thrombin inhibitors may offer an advantage over standard adjunctive therapies. We randomized 336 patients with acute MI at 33 sites to receive 1 of 5 doses of efegatran sulfate, a direct thrombin inhibitor, or heparin for 72 to 96 hours, both with accelerated alteplase and aspirin. The primary end point was the incidence of thrombolytic failure (death, reinfarction, or TIMI grade 0-2 flow in the infarct artery from 90 minutes to discharge or 30 days, whichever occurred earlier). Significantly more patients randomized to efegatran had evidence of heart failure at admission. The lowest-dose efegatran arm was terminated at 15 patients because of unacceptably increased thrombolytic failure. The primary end point occurred in 53.0% of patients treated with heparin, in 53.8% of patients treated with efegatran overall (P =.90), and in 55.4% of patients given intermediate-dose efegatran (P =.74). These findings were unaffected after adjustment was done for baseline differences. Most bleeding was minor; major bleeding and the use of blood transfusions did not differ significantly by treatment. Three patients in the high-dose efegatran group had intracranial hemorrhage, as did 1 patient in the heparin group. Continuous ST monitoring showed a shorter time to recovery for the efegatran group (median 107 minutes) compared with the heparin group (154 minutes; P =.025). Efegatran sulfate appeared to offer no clear advantage over heparin as an adjunct to thrombolysis for acute myocardial infarction, although there may be a modest improvement in time to reperfusion.

  11. Characteristics, management and response to alteplase in China versus non-China participants of the ENCHANTED trial.

    PubMed

    Song, Lily; Wang, Xia; Robinson, Thompson; Lindley, Richard I; Arima, Hisatomi; Lavados, Pablo M; Chen, Xiaoying; Chalmers, John; Anderson, Craig S

    2017-06-01

    The characteristics of patients with acute ischaemic stroke (AIS) and their management vary across regions, which may influence outcomes. We examined for differential patterns of outcome between China and non-China participants of the ENhanced Control of Hypertension And Thrombolysis strokE stuDy (ENCHANTED), which tested different alteplase doses in AIS. ENCHANTED was an international, multicentre, open, blinded-endpoint trial of the effects of low-dose (0.6 mg/kg) versus standard-dose (0.9 mg/kg) intravenous alteplase on 90-day disability outcomes and symptomatic intracerebral haemorrhage (sICH) in 3310 patients with AIS. Participants (n=1419, 48%) in China were younger, and more often male, hypertensive and with prior stroke and coronary artery disease, but less likely to have atrial fibrillation and use antihypertensive, antithrombotic and lipid-lowering agents, compared with non-China patients with AIS. Although China participants had more AIS due to large artery occlusion, were treated later and had differing ancillary management, there was no significant difference in 90-day modified Rankin scale scores 2-6 (55.6% vs 47.8%; OR, adjusted for baseline and management factors 0.87 (95% CI 0.71 to 1.07; p=0.20)) and risk of sICH (Safe Implementation of Thrombolysis in Stroke-Monitoring Study criteria: 1.4% vs 1.8%; p=0.12) compared with non-China participants. There was no heterogeneity in the treatment effects of low-dose versus standard-dose alteplase between China and non-China participants. Patients with AIS recruited to the ENCHANTED trial in China had similar outcomes in response to thrombolysis treatment despite significantly differing demographic, clinical and management factors to patients with AIS in other regions.

  12. Quality Improvement in Acute Ischemic Stroke Care in Taiwan: The Breakthrough Collaborative in Stroke

    PubMed Central

    Chern, Chang-Ming; Lee, Tsong-Hai; Tang, Sung-Chun; Tsai, Li-Kai; Liao, Hsun-Hsiang; Chang, Hang; LaBresh, Kenneth A.; Lin, Hung-Jung; Chiou, Hung-Yi; Chiu, Hou-Chang; Lien, Li-Ming

    2016-01-01

    In the management of acute ischemic stroke, guideline adherence is often suboptimal, particularly for intravenous thrombolysis or anticoagulation for atrial fibrillation. We sought to improve stroke care quality via a collaborative model, the Breakthrough Series (BTS)-Stroke activity, in a nationwide, multi-center activity in Taiwan. A BTS Collaborative, a short-term learning system for a large number of multidisciplinary teams from hospitals, was applied to enhance acute ischemic stroke care quality. Twenty-four hospitals participated in and submitted data for this stroke quality improvement campaign in 2010–2011. Totally, 14 stroke quality measures, adopted from the Get With The Guideline (GWTG)-Stroke program, were used to evaluate the performance and outcome of the ischemic stroke patients. Data for a one-year period from 24 hospitals with 13,181 acute ischemic stroke patients were analyzed. In 14 hospitals, most stroke quality measures improved significantly during the BTS-activity compared with a pre-BTS-Stroke activity period (2006–08). The rate of intravenous thrombolysis increased from 1.2% to 4.6%, door-to-needle time ≤60 minutes improved from 7.1% to 50.8%, symptomatic hemorrhage after intravenous thrombolysis decreased from 11.0% to 5.6%, and anticoagulation therapy for atrial fibrillation increased from 32.1% to 64.1%. The yearly composite measures of five stroke quality measures revealed significant improvements from 2006 to 2011 (75% to 86.3%, p<0.001). The quarterly composite measures also improved significantly during the BTS-Stroke activity. In conclusion, a BTS collaborative model is associated with improved guideline adherence for patients with acute ischemic stroke. GWTG-Stroke recommendations can be successfully applied in countries besides the United States. PMID:27487190

  13. Quality Improvement in Acute Ischemic Stroke Care in Taiwan: The Breakthrough Collaborative in Stroke.

    PubMed

    Hsieh, Fang-I; Jeng, Jiann-Shing; Chern, Chang-Ming; Lee, Tsong-Hai; Tang, Sung-Chun; Tsai, Li-Kai; Liao, Hsun-Hsiang; Chang, Hang; LaBresh, Kenneth A; Lin, Hung-Jung; Chiou, Hung-Yi; Chiu, Hou-Chang; Lien, Li-Ming

    2016-01-01

    In the management of acute ischemic stroke, guideline adherence is often suboptimal, particularly for intravenous thrombolysis or anticoagulation for atrial fibrillation. We sought to improve stroke care quality via a collaborative model, the Breakthrough Series (BTS)-Stroke activity, in a nationwide, multi-center activity in Taiwan. A BTS Collaborative, a short-term learning system for a large number of multidisciplinary teams from hospitals, was applied to enhance acute ischemic stroke care quality. Twenty-four hospitals participated in and submitted data for this stroke quality improvement campaign in 2010-2011. Totally, 14 stroke quality measures, adopted from the Get With The Guideline (GWTG)-Stroke program, were used to evaluate the performance and outcome of the ischemic stroke patients. Data for a one-year period from 24 hospitals with 13,181 acute ischemic stroke patients were analyzed. In 14 hospitals, most stroke quality measures improved significantly during the BTS-activity compared with a pre-BTS-Stroke activity period (2006-08). The rate of intravenous thrombolysis increased from 1.2% to 4.6%, door-to-needle time ≤60 minutes improved from 7.1% to 50.8%, symptomatic hemorrhage after intravenous thrombolysis decreased from 11.0% to 5.6%, and anticoagulation therapy for atrial fibrillation increased from 32.1% to 64.1%. The yearly composite measures of five stroke quality measures revealed significant improvements from 2006 to 2011 (75% to 86.3%, p<0.001). The quarterly composite measures also improved significantly during the BTS-Stroke activity. In conclusion, a BTS collaborative model is associated with improved guideline adherence for patients with acute ischemic stroke. GWTG-Stroke recommendations can be successfully applied in countries besides the United States.

  14. Contrast-Enhanced Ultrasound as a New Investigative Tool in Diagnostic Imaging of Muscle Injuries-A Pilot Study Evaluating Conventional Ultrasound, CEUS, and Findings in MRI.

    PubMed

    Hotfiel, Thilo; Heiss, Rafael; Swoboda, Bernd; Kellermann, Marion; Gelse, Kolja; Grim, Casper; Strobel, Deike; Wildner, Dane

    2018-07-01

    To emphasize the diagnostic value of contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries with different degrees of severity by comparing findings to established imaging modalities such as conventional ultrasound and magnetic resonance imaging (MRI). Case series. Institutional study. Conventional ultrasound and CEUS were performed in the Department of Internal Medicine. Magnetic resonance imaging was carried out in the Department of Radiology within the Magnetom Avanto 1.5T and Magnetom Skyra fit 3T (Siemens Healthineers, Erlangen, Germany) and in the Institution of Imaging Diagnostics and Therapy (Magnetom Avanto 1.5T; Siemens, Erlangen, Germany). Fifteen patients who underwent an acute muscle injury were recruited. The appearance and detectable size of muscle injuries were compared between each imaging modality. The injuries were assessed by 3 independent observers and blinded between imaging modalities. All 15 injuries were identified on MRI and CEUS, whereas 10 injuries showed abnormalities in conventional ultrasound. The determination and measurement revealed significant differences between conventional ultrasound and CEUS depending on injury severity. Contrast-enhanced ultrasound revealed an impairment of microcirculation in grade I lesions (corresponding to intramuscular edema observed in MRI), which was not detectable using conventional ultrasound. Our results indicate that performing CEUS seems to be a sensitive additional diagnostic modality in the early assessment of muscle injuries. Our results highlight the advantages of CEUS in the imaging of low-grade lesions when compared with conventional ultrasound, as this was the more accurate modality for identifying intramuscular edema.

  15. Sonothrombolysis is effective with recombinant tissue-type plasminogen activator, but not with Abciximab. Results from an in vitro study with whole blood clots and platelet-rich clots.

    PubMed

    Eggers, Jürgen; Ossadnik, Stefan; Hütten, Heiko; Seidel, Günter

    2009-12-01

    Transcranial "diagnostic" ultrasound (US) has been shown to accelerate thrombolysis related to recombinant tissue-type plasminogen activator (rt-PA). In this in vitro study, we evaluated the potential of US to increase clot dissolution mediated by Abciximab (Abc) compared to rt-PA. The effect of 1.8-MHz pulsed wave (PW) Doppler US on dissolution of whole venous blood clots (WBC) and platelet-rich clots (PRC) treated with Abc and rt-PA was investigated in an in vitro model. Clot dissolution was measured by weight loss. Abc-related WBC dissolution was enhanced by additional US, but the effect was not any more detectable when the US was attenuated by a human temporal bone (US-tb). In PRC there was no additional effect of US on the Abc-related clot lysis. Rt-PA-related clot dissolution was increased by US in WBC and PRC as well, however, US-tb was only effective in WBC. The effect of insonation on WBC dissolution treated with the combination of Abc plus rt-PA was lower compared with those treated with rt-PA. In this in vitro experiment, the additional effect of "diagnostic" US in combination with Abc was only present in WBC and less strong than with rt-PA. The results do not support the use of Abc for sonothrombolysis targeting both, fibrin-rich and platelet-rich clots. In contrast, US when combined with rt-PA increases dissolution in both, WBC and PRC as well.

  16. Hemocoagulase Combined with Microbubble-Enhanced Ultrasound Cavitation for Augmented Ablation of Microvasculature in Rabbit VX2 Liver Tumors.

    PubMed

    Yang, Qian; Tang, Peng; He, Guangbin; Ge, Shuping; Liu, Liwen; Zhou, Xiaodong

    2017-08-01

    We investigated a new method for combining microbubble-enhanced ultrasound cavitation (MEUC) with hemocoagulase (HC) atrox. Our goal was to induce embolic effects in the vasculature and combine these with an anti-angiogenic treatment strategy. Fourteen days after being implanted with a single slice of the liver VX2 tumor, rabbits were randomly divided into five groups: (i) a control group injected intra-venously with saline using a micropump; (ii) a group given only an injection of HC; (iii) a group treated only with ultrasound cavitation; (iv) a group treated with MEUC; (v) a group treated with MEUC + HC. Contrast-enhanced ultrasound was performed before treatment and 1 h and 7 d post-treatment to measure tumor size, enhancement and necrosis range. QontraXt software was used to determine the time-intensity curve of tumor blood perfusion and microvascular changes. At 1 h and 7 d after treatment with MEUC + HC, the parameters of the time-intensity curve, which included peak value, regional blood volume, regional blood flow and area under the curve value and which were measured using contrast-enhanced ultrasound, were significantly lower than those of the other treatment groups. The MEUC + HC treatment group exhibited significant growth inhibition relative to the ultrasound cavitation only, HC and MEUC treatment groups. No damage was observed in the surrounding normal tissues. These results support the feasibility of reducing the blood perfusion of rabbit VX2 liver tumors using a new method that combines MEUC and HC. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  17. Ultrasound-enhanced bioscouring of greige cotton: regression analysis of process factors

    USDA-ARS?s Scientific Manuscript database

    Ultrasound-enhanced bioscouring process factors for greige cotton fabric are examined using custom experimental design utilizing statistical principles. An equation is presented which predicts bioscouring performance based upon percent reflectance values obtained from UV-Vis measurements of rutheniu...

  18. Enhanced cytotoxic effect of cisplatin using diagnostic ultrasound and microbubbles in vitro

    NASA Astrophysics Data System (ADS)

    Sasaki, Noboru; Nakamura, Kensuke; Murakami, Masahiro; Lim, Sue Yee; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2012-10-01

    Diagnostic ultrasound has accomplished drug and gene delivery by ultrasound targeted microbubble destruction (UTMD). However, the efficacy of delivery is still relatively low. Therefore, we optimized conditions of UTMD using diagnostic ultrasound and ultrasound contrast agent microbubbles. Canine thyroid adenocarcinoma cells were cultured in a 96-well plate. After addition of cisplatin and Sonazoid®, the plate was inverted to raise microbubbles near cells and incubated. Cells were exposed to diagnostic ultrasound using a linear probe operated in the contrast harmonic imaging mode. The center frequency was 2.5 MHz with a mechanical index of 1.33 and a frame rate of 48 frames/sec. Cytotoxic effect of cisplatin was evaluated 24h after exposure using trypan blue dye exclusion test. We optimized incubation duration, cisplatin concentration, and the relationship between microbubble concentration and exposure duration. The optimum enhancement was observed at incubation duration of 5min, cisplatin concentration of 1 μg/ml, and microbubble concentration of 2.4 × 105 microbubbles/ml. Exposure duration did not influence the enhancement at the microbubble concentration of 2.4 × 105 microbubbles/ml. Our results suggest that relative low concentrations of drug and microbubbles with short exposure duration might be sufficient for drug delivery by UTMD using diagnostic ultrasound.

  19. Dynamic Contrast-Enhanced Ultrasound Identifies Microcirculatory Alterations in Sepsis-Induced Acute Kidney Injury.

    PubMed

    Lima, Alexandre; van Rooij, Tom; Ergin, Bulent; Sorelli, Michele; Ince, Yasin; Specht, Patricia A C; Mik, Egbert G; Bocchi, Leonardo; Kooiman, Klazina; de Jong, Nico; Ince, Can

    2018-05-15

    We developed quantitative methods to analyze microbubble kinetics based on renal contrast-enhanced ultrasound imaging combined with measurements of sublingual microcirculation on a fixed area to quantify early microvascular alterations in sepsis-induced acute kidney injury. Prospective controlled animal experiment study. Hospital-affiliated animal research institution. Fifteen female pigs. The animals were instrumented with a renal artery flow probe after surgically exposing the kidney. Nine animals were given IV infusion of lipopolysaccharide to induce septic shock, and six were used as controls. Contrast-enhanced ultrasound imaging was performed on the kidney before, during, and after having induced shock. Sublingual microcirculation was measured continuously using the Cytocam on the same spot. Contrast-enhanced ultrasound effectively allowed us to develop new analytical methods to measure dynamic variations in renal microvascular perfusion during shock and resuscitation. Renal microvascular hypoperfusion was quantified by decreased peak enhancement and an increased ratio of the final plateau intensity to peak enhancement. Reduced intrarenal blood flow could be estimated by measuring the microbubble transit times between the interlobar arteries and capillary vessels in the renal cortex. Sublingual microcirculation measured using the Cytocam in a fixed area showed decreased functional capillary density associated with plugged sublingual capillary vessels that persisted during and after fluid resuscitation. In our lipopolysaccharide model, with resuscitation targeted at blood pressure, the contrast-enhanced ultrasound imaging can identify renal microvascular alterations by showing prolonged contrast enhancement in microcirculation during shock, worsened by resuscitation with fluids. Concomitant analysis of sublingual microcirculation mirrored those observed in the renal microcirculation.

  20. Using low frequency and intensity ultrasound to enhance start-up and operation performance of Anammox process inoculated with the conventional sludge.

    PubMed

    Wang, Tao; Zhang, Diandian; Sun, Yating; Zhou, Shanshan; Li, Lin; Shao, Jingjing

    2018-04-01

    A lab-scale ultrasound enhancing Anammox reactor (R1) was established and irradiated once a week by ultrasound with the optimal parameter (frequency of 25 kHz, intensity of 0.2 W cm -2 and exposure time of 3 min) obtained by batch experiments. R1 and the controlled Anammox reactor (R2) without exposure to the ultrasound were operated in parallel. The start-up period of Anammox process (53 days) in R1 was shorter than that (61 days) in R2. The nitrogen loading-enhancing period (day 53-day 135) in R1 was also shorter than that (day 61-day 151) in R2. At the end of the nitrogen loading-enhancing period, NLR (0.76 kg N m -3  d -1 ) and NRR (0.68 kg N m -3  d -1 ) of R1 were both higher than NLR (0.66 kg N m -3  d -1 ) and NRR (0.56 kg N m -3  d -1 ) of R2. Moreover, The stability of Anammox process in R1 was better than that in R2. The results demonstrated that the periodical irradiation of ultrasound enhanced the start-up and operational performance of Anammox reactor. Microbial community analysis indicated that the ultrasound accelerated the microbial succession from some other bacteria to Anammox bacteria so that shorten the start-up period of Anammox process from the conventional activated sludge. It also indicated that the ultrasound strengthened the competitive advantage of Candidatus Kuenenia stuttgartiensis in Anammox bacteria of the mature sludge so as to enhance the nitrogen removal performance of the Anammox reactor under the operation condition of high nitrogen loading. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. [Novel dianostics and therapeutics with ultrasound technologies and nanotechnologies].

    PubMed

    Suzuki, Ryo; Oda, Yusuke; Omata, Daiki; Sawaguchi, Yoshikazu; Negishi, Yoichi; Maruyama, Kazuo

    2013-01-01

    Ultrasound is a good tool for theranostics due to have multi-potency both of diagnostics with sonography and therapeutics with high intensity focused ultrasound (HIFU). In addition, microbubbles and nanobubbles are utilized as not only contrast imaging agent but also enhancer of drug and gene delivery by combination of ultrasound. Recently, we developed novel liposomal nanobubbles (Bubble liposomes) which were containing perfluoropropane. Bubble liposomes induced jet stream by low intensity ultrasound exposure and resulted in enhancing permeability of cell membrane. This phenomenon has been utilized as driving force for drug and gene delivery. On the other hand, the combination of Bubble liposomes and high intensity ultrasound induces strong jet stream and increase temperature. This condition can directly damage to tumor cells, we are applying this for cancer therapy. Therefore, their combination has potency for various cancer therapies such as gene therapy, immunotherapy and hyperthermia. In this review, we discuss about cancer therapy by the combination of Bubble liposomes and ultrasound.

  2. Ultrasonically enhanced fractionation of milk fat in a litre-scale prototype vessel.

    PubMed

    Leong, Thomas; Johansson, Linda; Mawson, Raymond; McArthur, Sally L; Manasseh, Richard; Juliano, Pablo

    2016-01-01

    The ultrasonic fractionation of milk fat in whole milk to fractions with distinct particle size distributions was demonstrated using a stage-based ultrasound-enhanced gravity separation protocol. Firstly, a single stage ultrasound gravity separation was characterised after various sonication durations (5-20 min) with a mass balance, where defined volume partitions were removed across the height of the separation vessel to determine the fat content and size distribution of fat droplets. Subsequent trials using ultrasound-enhanced gravity separation were carried out in three consecutive stages. Each stage consisted of 5 min sonication, with single and dual transducer configurations at 1 MHz and 2 MHz, followed by aliquot collection for particle size characterisation of the formed layers located at the bottom and top of the vessel. After each sonication stage, gentle removal of the separated fat layer located at the top was performed. Results indicated that ultrasound promoted the formation of a gradient of vertically increasing fat concentration and particle size across the height of the separation vessel, which became more pronounced with extended sonication time. Ultrasound-enhanced fractionation provided fat enriched fractions located at the top of the vessel of up to 13 ± 1% (w/v) with larger globules present in the particle size distributions. In contrast, semi-skim milk fractions located at the bottom of the vessel as low as 1.2 ± 0.01% (w/v) could be produced, containing proportionally smaller sized fat globules. Particle size differentiation was enhanced at higher ultrasound energy input (up to 347 W/L). In particular, dual transducer after three-stage operation at maximum energy input provided highest mean particle size differentiation with up to 0.9 μm reduction in the semi-skim fractions. Higher frequency ultrasound at 2 MHz was more effective in manipulating smaller sized fat globules retained in the later stages of skimming than 1 MHz. While 2 MHz ultrasound removed 59 ± 2% of the fat contained in the initial sample, only 47 ± 2% was removed with 1 MHz after 3 ultrasound-assisted fractionation stages. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Scale-up of an ultrasound-enhanced bioscouring process

    USDA-ARS?s Scientific Manuscript database

    Using previously determined optimized reaction conditions, an ultrasound-enhanced bioscouring process was scaled to ten gallon capacity and a system of rollers was added which allowed for continuous fabric feed and equipment operation. UV-Vis photospectroscopic data from bioscoured fabric samples co...

  4. Thrombolysis in the age of Primary Percutaneous Coronary Intervention: Mini-Review and Meta-analysis of Early PCI

    PubMed Central

    Al Shammeri, O; Garcia, LA

    2013-01-01

    Objective Primary Percutaneous Coronary Intervention (PCI) is the treatment of choice for ST-segment Elevation Myocardial Infarction (STEMI) if performed within 90 minutes from first medical contact. However, primary PCI is only available for less than 25% of patients with STEMI. Early PCI or Pharmaco-invasive strategy has evolved from facilitated PCI but with more delayed timing from thrombolysis to PCI. Aim Assess the safety and effectiveness of Early PCI. Patients and Method We reviewed the data of the available therapy options for patients with STEMI. Then we performed a meta-analysis for all randomized controlled trials of early PCI versus standard therapy Results Five studies fulfilled our inclusion criteria. Our meta-analysis showed improved cardiovascular events with early PCI compared to standard therapy (odd ratio of 0.54; 95% Confidence interval 0.47-0.7, p<0.001). There were no significant bleeding complications when doing early PCI 4 to 24 hours after successful thrombolysis Conclusion Early PCI should be done to all STEMI patients within 24 hours after successful thrombolysis. PMID:23559909

  5. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    PubMed

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  6. The free-radical scavenger edaravone accelerates thrombolysis with alteplase in an experimental thrombosis model.

    PubMed

    Yamashita, Tsutomu; Sato, Takumi; Sakamoto, Kumi; Ishii, Hiromitsu; Yamamoto, Junichiro

    2015-06-01

    Reperfusion injury after thrombolytic therapy can have adverse neurologic effects. The free-radical scavenger edaravone is used in combination with the recombinant tissue plasminogen activator alteplase to treat acute ischemic stroke. However, basic investigations of this combination use remain inadequate. Here, we used an in vivo model to investigate the effects of edaravone on alteplase-induced thrombolysis. Thrombolysis was evaluated by using a He-Ne-laser-induced thrombosis model in rat mesenteric microvessels. Changes in thrombus volume were analyzed with the image analysis software Image-Pro Plus (Media Cybernetics, USA). There were three experimental groups (placebo, alteplase 0.6 mg/kg, alteplase 0.6 mg/kg + edaravone 10.5 mg/kg). Sequential changes (0 to 60 min) in thrombus volume were compared by using a relative optical density method that we had used previously. In the placebo group, the thrombus volume at 60 min, reflecting the extent of thrombolysis, was 97.2% ± 5.7% of the initial value. In the alteplase group, thrombus volume decreased to 70.7% ± 4.1% (P<0.01) after 20 min and 14.2% ± 6.6% after 60 min. In the alteplase+edaravone group, thrombus volume decreased to 66.9% ± 7.2% (P<0.001) after 10 min and 10.9% ± 2.3% after 60 min. These results support the hypothesis that edaravone accelerates thrombolysis by alteplase. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Outcomes of catheter-directed treatment of lower extremity deep vein thrombosis of patients presenting to a tertiary care hospital.

    PubMed

    Sundar, Gaurav; Keshava, Shyamkumar N; Moses, Vinu; Chiramel, George K; Ahmed, Munawwar; Mammen, Suraj; Aggarwal, Sunil; Stephen, Edwin

    2016-01-01

    Lower extremity deep vein thrombosis (DVT) is a common illness with an annual incidence of 1 per 1000 adults. The major long-term complication of DVT is post-thrombotic syndrome (PTS) which occurs in up to 60% of patients within 2 years of an episode of DVT. We aim to evaluate the outcomes of catheter-directed treatment (CDT) for symptomatic acute or subacute lower extremity DVT. A retrospective 12-year study was conducted on the outcomes of CDT on 54 consecutive patients who presented with acute or subacute lower extremity DVT to our hospital. Descriptive summary statistics and the Chi-square test were used to measure the outcomes of CDT. Grade 3 thrombolysis was achieved in 25 (46.3%) patients, grade 2 thrombolysis in 25 (46.3%) patients, and grade 1 thrombolysis in 4 (7.4%) patients. Significant recanalization (grade 2 or 3 thrombolysis) was possible in 50 (92.6%) patients. There was no statistically significant difference in the percentage of significant recanalization that could be achieved between patients who underwent CDT before and after 10 days. There was no significant difference between the thrombolysis achieved between urokinase and r-tPA. PTS was seen in 33% of the patients. Major complications were seen in 5.5% of the patients. CDT is a safe and effective therapeutic technique in patients with acute and subacute lower extremity DVT, if appropriate patient selection is made.

  8. Feasibility of acute thrombolytic therapy for stroke.

    PubMed

    Nandigam, K; Narayan, S K; Elangovan, S; Dutta, T K; Sethuraman, K R; Das, A K

    2003-12-01

    Thrombolysis is an expensive medical intervention for ischemic stroke and hence there is a need to study the feasibility of thrombolysis in rural India. To asses the feasibility and limitations of providing thrombolytic therapy to acute ischemic stroke patients in a rural Indian set-up. The first 64 consecutive patients registered under the Acute Stroke Registry in a university referral hospital with a rural catchment area were studied as per a detailed protocol and questionnaire. Of the 64 patients 44 were ischemic strokes, and 20 were hemorrhagic. Thirteen (29.55%) patients with ischemic stroke reached a center with CT scan facility within 3 hours, of whom only 7 (15.91%) were eligible to receive thrombolytic therapy as per the existing clinical and radiological criteria, but none received the therapy. Of the remaining 31 (70.45%) who arrived late, 11 (25%) had no clinical and radiological contraindications for thrombolysis, except the time factor. All the patients belonged to a low socioeconomic status and a rural background. Though a large proportion of ischemic stroke patients were eligible to receive thrombolytic therapy, the majority could not reach a center with adequate facilities within the recommended time window. More alarmingly, even for those patients who reached within the time window, no significant attempt was made to initiate thrombolysis. These data call not only for attention to improve existing patient transport facilities, but also for improving the awareness of efficacy and therapeutic window of thrombolysis in stroke, among the public as well as primary care doctors.

  9. A collimated focused ultrasound beam of high acoustic transmission and minimum diffraction achieved by using a lens with subwavelength structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Zhou; Tu, Juan; Cheng, Jianchun

    An acoustic focusing lens incorporated with periodically aligned subwavelength grooves corrugated on its spherical surface has been developed. It is demonstrated theoretically and experimentally that acoustic focusing achieved by using the lens can suppress the relative side-lobe amplitudes, enhance the focal gain, and minimize the shifting of the focus. Use of the lens coupled with a planar ultrasound transducer can generate an ultrasound beam with enhanced acoustic transmission and collimation effect, which offers the capability of improving the safety, efficiency, and accuracy of targeted surgery implemented by high intensity focused ultrasound.

  10. Development and evaluation of a novel VEGFR2-targeted nanoscale ultrasound contrast agents

    NASA Astrophysics Data System (ADS)

    Yu, Houqiang; Li, Chunfang; He, Xiaoling; Zhou, Qibing; Ding, Mingyue

    2016-04-01

    Recent literatures have reported that the targeted nanoscale ultrasound contrast agents are becoming more and more important in medical application, like ultrasound imaging, detection of perfusion, drug delivery and molecular imaging and so on. In this study, we fabricated an uniform nanoscale bubbles (257 nm with the polydispersity index of 0.458) by incorporation of antibody targeted to vascular endothelial growth factor receptor 2 (VEGFR2) into the nanobubbles membrane by using avidin-biotin interaction. Some fundamental characterizations such as nanobubble suspension, surface morphology, particle size distribution and zeta potential were investigated. The concentration and time-intensity curves (TICs) were obtained with a self-made ultrasound experimental setup in vitro evaluation. In addition, in order to evaluate the contrast enhancement ability and the potential tumor-targeted ability in vivo, normal Wistar rats and nude female BALB/c mice were intravascular administration of the nanobubbles via tail vein injection, respectively. Significant contrast enhancement of ultrasound imaging within liver and tumor were visualized. These experiments demonstrated that the targeted nanobubbles is efficient in ultrasound molecular imaging by enhancement of the contrast effect and have potential capacity for targeted tumor diagnosis and therapy in the future.

  11. Real-time 3-D contrast-enhanced transcranial ultrasound and aberration correction.

    PubMed

    Ivancevich, Nikolas M; Pinton, Gianmarco F; Nicoletto, Heather A; Bennett, Ellen; Laskowitz, Daniel T; Smith, Stephen W

    2008-09-01

    Contrast-enhanced (CE) transcranial ultrasound (US) and reconstructed 3-D transcranial ultrasound have shown advantages over traditional methods in a variety of cerebrovascular diseases. We present the results from a novel ultrasound technique, namely real-time 3-D contrast-enhanced transcranial ultrasound. Using real-time 3-D (RT3D) ultrasound and microbubble contrast agent, we scanned 17 healthy volunteers via a single temporal window and nine via the suboccipital window and report our detection rates for the major cerebral vessels. In 71% of subjects, both of our observers identified the ipsilateral circle of Willis from the temporal window, and in 59% we imaged the entire circle of Willis. From the suboccipital window, both observers detected the entire vertebrobasilar circulation in 22% of subjects, and in 44%, the basilar artery. After performing phase aberration correction on one subject, we were able to increase the diagnostic value of the scan, detecting a vessel not present in the uncorrected scan. These preliminary results suggest that RT3D CE transcranial US and RT3D CE transcranial US with phase aberration correction have the potential to greatly impact the field of neurosonology.

  12. Real-Time 3D Contrast-Enhanced Transcranial Ultrasound and Aberration Correction

    PubMed Central

    Ivancevich, Nikolas M.; Pinton, Gianmarco F.; Nicoletto, Heather A.; Bennett, Ellen; Laskowitz, Daniel T.; Smith, Stephen W.

    2008-01-01

    Contrast-enhanced (CE) transcranial ultrasound (US) and reconstructed 3D transcranial ultrasound have shown advantages over traditional methods in a variety of cerebrovascular diseases. We present the results from a novel ultrasound technique, namely real-time 3D contrast-enhanced transcranial ultrasound. Using real-time 3D (RT3D) ultrasound and micro-bubble contrast agent, we scanned 17 healthy volunteers via a single temporal window and 9 via the sub-occipital window and report our detection rates for the major cerebral vessels. In 71% of subjects, both of our observers identified the ipsilateral circle of Willis from the temporal window, and in 59% we imaged the entire circle of Willis. From the sub-occipital window, both observers detected the entire vertebrobasilar circulation in 22% of subjects, and in 44% the basilar artery. After performing phase aberration correction on one subject, we were able to increase the diagnostic value of the scan, detecting a vessel not present in the uncorrected scan. These preliminary results suggest that RT3D CE transcranial US and RT3D CE transcranial US with phase aberration correction have the potential to greatly impact the field of neurosonology. PMID:18395321

  13. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.

  14. Ultrasound-enhanced bioscouring of greige cotton: regression analysis of process factors

    USDA-ARS?s Scientific Manuscript database

    Process factors of enzyme concentration, time, power and frequency were investigated for ultrasound-enhanced bioscouring of greige cotton. A fractional factorial experimental design and subsequent regression analysis of the process factors were employed to determine the significance of each factor a...

  15. Current status of intravenous thrombolysis for acute ischemic stroke in Asia.

    PubMed

    Sharma, Vijay K; Ng, Kay W P; Venketasubramanian, Narayanaswamy; Saqqur, Maher; Teoh, Hock L; Kaul, Subash; Srivastava, Padma M V; Sergentanis, Theodoris; Suwanwela, Nijasri; Nguyen, Thang H; Lawrence Wong, K S; Chan, Bernard P L

    2011-12-01

    Data regarding thrombolysis for acute ischemic stroke in Asia are scarce and only a small percentage of patients are thrombolysed. The dose of intravenous tissue plasminogen activator (IV-tPA) in Asia remains controversial. Case-controlled observation studies in Asia included only Japanese patients and suggested the clinical efficacy and safety of low-dose IV-tPA (0.6 mg/kg body weight; max 60 mg) comparable to standard dose (0.9 mg/kg body weight; max. 90 mg). Reduced treatment cost, lower symptomatic intracerebral hemorrhage risk and comparable efficacy encouraged many Asian centers to adopt low-dose or even variable-dose IV-tPA regimens. We evaluated various Asian thrombolysis studies and compared with SITS-MOST registry and NINDS trial. We included the published studies on acute ischemic stroke thrombolysis in Asia. Unadjusted relative risks and 95% Confidence intervals were calculated for each study. Pooled estimates from random effects models were used because the tests for heterogeneity were significant. We found only 18 publications regarding acute ischemic stroke thrombolysis in Asia that included total of 9300 patients. Owing to ethnic differences, stroke severity, small number of cases in individual reports, outcome measures and tPA dose regimes, it is difficult to compare these studies. Functional outcomes were almost similar (to Japanese studies) when lower-dose IV-tPA was used in non-Japanese populations across Asia. Interestingly, with standard dose IV-tPA, considerably better functional outcomes were observed, without increasing symptomatic intracerebral hemorrhage rates. Variable dose regimens of IV-tPA are used across Asia without any reliable or established evidence. Establishing a uniform IV-tPA regimen is essential since the rapid improvements in health-care facilities and public awareness are expected to increase the rates of thrombolysis in Asia. © 2011 The Authors. International Journal of Stroke © 2011 World Stroke Organization.

  16. External Validation of the ASTRAL and DRAGON Scores for Prediction of Functional Outcome in Stroke.

    PubMed

    Cooray, Charith; Mazya, Michael; Bottai, Matteo; Dorado, Laura; Skoda, Ondrej; Toni, Danilo; Ford, Gary A; Wahlgren, Nils; Ahmed, Niaz

    2016-06-01

    ASTRAL (Acute Stroke Registry and Analysis of Lausanne) and DRAGON (includes dense middle cerebral artery sign, prestroke modified Rankin Scale score, age, glucose, onset to treatment, National Institutes of Health Stroke Scale score) are 2 recently developed scores for predicting functional outcome after acute stroke in unselected acute ischemic stroke patients and in patients treated with intravenous thrombolysis, respectively. We aimed to perform external validation of these scores to assess their predictive performance in the large multicentre Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register. We calculated the ASTRAL and DRAGON scores in 36 131 and 33 716 patients, respectively, registered in Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register between 2003 and 2013. The proportion of patients with 3-month modified Rankin Scale scores of 3 to 6 was observed for each score point and compared with the predicted proportion according to the risk scores. Calibration was assessed using calibration plots, and predictive performance was assessed using area under the curve of the receiver operating characteristic. Multivariate logistic regression coefficients for the variables in the 2 scores were compared with the original derivation cohorts. The ASTRAL showed an area under the curve of 0.790 (95% confidence interval, 0.786-0.795) and the DRAGON an area under the curve of 0.774 (95% confidence interval, 0.769-0.779). All ASTRAL parameters except range of visual fields and all DRAGON parameters were significantly associated with functional outcome in multivariate analysis. The ASTRAL and DRAGON scores show an acceptable predictive performance. ASTRAL does not require imaging-data and therefore may have an advantage for the use in prehospital patient assessment. Prospective studies of both scores evaluating the impact of their use on patient outcomes after intravenous thrombolysis and endovascular therapy are needed. © 2016 American Heart Association, Inc.

  17. Floating arterial thrombus related stroke treated by intravenous thrombolysis.

    PubMed

    Vanacker, P; Cordier, M; Janbieh, J; Federau, C; Michel, P

    2014-01-01

    The effects of intravenous thrombolysis on floating thrombi in cervical and intracranial arteries of acute ischemic stroke patients are unknown. Similarly, the best prevention methods of early recurrences remain controversial. This study aimed to describe the clinical and radiological outcome of thrombolyzed strokes with floating thrombi. We retrospectively analyzed all thrombolyzed stroke patients in our institution between 2003 and 2010 with floating thrombi on acute CT-angiography before the intravenous thrombolysis. The floating thrombus was diagnosed if an elongated thrombus of at least 5 mm length, completely surrounded by contrast on supra-aortic neck or intracerebral arteries, was present on CT-angiography. Demographics, vascular risk factors, and comorbidities were recorded and stroke etiology was determined after a standardized workup. Repeat arterial imaging was performed by CTA at 24 h or before if clinical worsening was noted and then by Doppler and MRA during the first week and at four months. Of 409 thrombolyzed stroke patients undergoing acute CT Angiography, seven (1.7%) had a floating thrombus; of these seven, six had it in the anterior circulation. Demographics, risk factors and stroke severity of these patients were comparable to the other thrombolyzed patients. After intravenous thrombolysis, the floating thrombi resolved completely at 24 h in four of the patients, whereas one had an early recurrent stroke and one developed progressive worsening. One patient developed early occlusion of the carotid artery with floating thrombus and subsequently a TIA. The two patients with a stable floating thrombus had no clinical recurrences. In the literature, only one of four reported cases were found to have a thrombolysis-related early recurrence. Long-term outcome seemed similar in thrombolyzed patients with floating thrombus, despite a possible increase of very early recurrence. It remains to be established whether acute mechanical thrombectomy could be a safer and more effective treatment to prevent early recurrence. However, intravenous thrombolysis should not be withheld in eligible stroke patients. © 2014 S. Karger AG, Basel.

  18. THrombolysis for Acute Wake-up and unclear-onset Strokes with alteplase at 0·6 mg/kg (THAWS) Trial

    PubMed Central

    Koga, Masatoshi; Toyoda, Kazunori; Kimura, Kazumi; Yamamoto, Haruko; Sasaki, Makoto; Hamasaki, Toshimitsu; Kitazono, Takanari; Aoki, Junya; Seki, Kenta; Homma, Kazunari; Sato, Shoichiro; Minematsu, Kazuo

    2014-01-01

    Rationale Because of lack of information regarding timing of stroke, patients who suffer stroke during sleep are generally ineligible for intravenous thrombolysis, although many of these patients could potentially recover with this treatment. Magnetic resonance image findings with positive diffusion-weighted imaging and no marked parenchymal hyperintensity on fluid-attenuated inversion recovery (negative pattern) can identify acute ischemic stroke patients within 4·5 h from symptom onset. Aims The THrombolysis for Acute Wake-up and unclear-onset Strokes with alteplase at 0·6 mg/kg trial aims to determine the efficacy and safety of intravenous thrombolysis with alteplase at 0·6 mg/kg body weight, the approved dose for Japanese stroke patients, using magnetic resonance image-based selection in ischemic stroke patients with unclear time of symptom onset, and compare findings with standard treatment. Design This is an investigator-initiated, multicenter, prospective, randomized, open-treatment, blinded-end-point clinical trial. The design is similar to the Efficacy and Safety of MRI-based Thrombolysis in Wake-up Stroke trial. Patients with unclear-onset time of stroke symptoms beyond 4·5 h and within 12 h after the time of the last-known-well period and within 4·5 h after symptom recognition, who showed a negative fluid-attenuated inversion recovery pattern, are randomized to either intravenous thrombolysis or standard treatment. Study outcomes The primary efficacy end-point is modified Rankin Scale 0–1 at 90 days. The safety outcome measures are symptomatic intracranial hemorrhage at 22–36 h, and major bleeding and mortality at 90 days. Discussion This trial may help determine if low-dose alteplase at 0·6 mg/kg should be recommended as a routine clinical strategy for ischemic stroke patients with unclear-onset time. PMID:25088843

  19. Stroke With Unknown Time of Symptom Onset: Baseline Clinical and Magnetic Resonance Imaging Data of the First Thousand Patients in WAKE-UP (Efficacy and Safety of MRI-Based Thrombolysis in Wake-Up Stroke: A Randomized, Doubleblind, Placebo-Controlled Trial).

    PubMed

    Thomalla, Götz; Boutitie, Florent; Fiebach, Jochen B; Simonsen, Claus Z; Nighoghossian, Norbert; Pedraza, Salvador; Lemmens, Robin; Roy, Pascal; Muir, Keith W; Ebinger, Martin; Ford, Ian; Cheng, Bastian; Galinovic, Ivana; Cho, Tae-Hee; Puig, Josep; Thijs, Vincent; Endres, Matthias; Fiehler, Jens; Gerloff, Christian

    2017-03-01

    We describe clinical and magnetic resonance imaging (MRI) characteristics of stroke patients with unknown time of symptom onset potentially eligible for thrombolysis from a large prospective cohort. We analyzed baseline data from WAKE-UP (Efficacy and Safety of MRI-Based Thrombolysis in Wake-Up Stroke: A Randomized, Doubleblind, Placebo-Controlled Trial), an investigator-initiated, randomized, placebo-controlled trial of MRI-based thrombolysis in stroke patients with unknown time of symptom onset. MRI judgment included assessment of the mismatch between visibility of the acute ischemic lesion on diffusion-weighted imaging and fluid-attenuated inversion recovery. Of 1005 patients included, diffusion-weighted imaging and fluid-attenuated inversion recovery mismatch was present in 479 patients (48.0%). Patients with daytime-unwitnessed stroke (n=138, 13.7%) had a shorter delay between symptom recognition and hospital arrival (1.5 versus 1.8 hours; P =0.002), a higher National Institutes of Stroke Scale score on admission (8 versus 6; P <0.001), and more often aphasia (72.5% versus 34.0%; P <0.001) when compared with stroke patients waking up from nighttime sleep. Frequency of diffusion-weighted imaging and fluid-attenuated inversion recovery mismatch was comparable between both groups (43.7% versus 48.7%; P =0.30). Almost half of the patients with unknown time of symptom onset stroke otherwise eligible for thrombolysis had MRI findings making them likely to be within a time window for safe and effective thrombolysis. Patients with daytime onset unwitnessed stroke differ from wake-up stroke patients with regards to clinical characteristics but are comparable in terms of MRI characteristics of lesion age. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01525290. URL: https://www.clinicaltrialsregister.eu. Unique identifier: 2011-005906-32. © 2017 American Heart Association, Inc.

  20. The metabolic syndrome is associated with a higher resistance to intravenous thrombolysis for acute ischemic stroke in women than in men.

    PubMed

    Arenillas, Juan F; Sandoval, Patricio; Pérez de la Ossa, Natalia; Millán, Mónica; Guerrero, Cristina; Escudero, Domingo; Dorado, Laura; López-Cancio, Elena; Castillo, José; Dávalos, Antoni

    2009-02-01

    The metabolic syndrome (MetS) might confer a higher resistance to intravenous thrombolysis in acute middle cerebral artery (MCA) ischemic stroke. MetS increases the risk of stroke in women to a greater extent than in men. We aimed to investigate whether there might be sex differences in the impact of MetS on the response to intravenous thrombolysis for acute MCA ischemic stroke. We prospectively studied consecutive ischemic stroke patients, treated with intravenous tissue-type plasminogen activator according to SITS-MOST criteria, with an MCA occlusion on prebolus transcranial Doppler examination. Resistance to thrombolysis was defined as the absence of complete MCA recanalization 24 hours after tissue-type plasminogen activator infusion by transcranial Doppler criteria. MetS was diagnosed according to the criteria established by the American Heart Association/National Heart, Lung, and Blood Institute 2005 statement. A total of 125 patients (75 men, 50 women; mean age, 67.6+/-11 years) were included. MetS was diagnosed in 76 (61%) patients. Resistance to clot lysis at 24 hours was observed in 53 (42%) patients. Two multivariate-adjusted, logistic-regression models identified that MetS was associated with a higher resistance to tissue-type plasminogen activator, independently of other significant baseline variables (odds ratio=9.8; 95% CI, 3.5 to 27.8; P=0.0001) and of the individual components of the MetS. The MetS was associated with a significantly higher odds of resistance to thrombolysis in women (odds ratio=17.5; 95% CI, 1.9 to 163.1) than in men (odds ratio=5.1; 95% CI, 1.6 to 15.6; P for interaction=0.0004). The effect of MetS on the resistance to intravenous thrombolysis for acute MCA ischemic stroke appears to be more pronounced in women than in men.

  1. Biliary lithotripsy can be enhanced with proper ultrasound probe position.

    PubMed

    Affronti, J; Flournoy, T; Akers, S; Baillie, J

    1992-04-01

    We have demonstrated in our in vitro system that an extracorporeal lithotripter utilizing a movable ultrasound probe can fragment gallstones more effectively when the ultrasound probe is not partially blocking shock waves. Using a pressure transducer we measured the pressures in the focal volume of a Wolf Piezolith 2300 lithotripter with the ultrasound probe fully extended and fully retracted. We also chose 12 pairs of twin gallstones, each taken from the same gallbladder. One stone from each pair was subjected to shock waves while the ultrasound probe was fully extended and the other treated while the probe was fully retracted. Shock wave pressures (which are converted to a measurable voltage output by our transducer) were clearly lower when the ultrasound probe was extended (5.45 volts; SEM = 0.10 volts) as compared to when the ultrasound scanner was retracted (6.7 volts: SEM = 0.08 volts). Significantly more shock waves were required to completely fragment stones when the ultrasound scanner was extended than when it was retracted (p = 0.01 using the nonparametric Wilcoxon's signed rank test). These results show that, in the lithotripter tested, an extended in-line ultrasound scanner can partially block shock waves. Retraction of an extendible ultrasound probe may enhance stone fragmentation when operating at the highest shock wave intensity.

  2. Varying ultrasound power level to distinguish surgical instruments and tissue.

    PubMed

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  3. Accelerated Training at Mach 20: A Brief Communication Submitted from the International Space Station

    NASA Technical Reports Server (NTRS)

    Foale, C. Michael; Kaleri, Alexander Y.; Sargsyan, Ashot E.; Hamilton, Douglas R.; Melton, Shannon; Martin, David; Dulchavsky, Scott A.

    2004-01-01

    The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed just-in-time training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This just-in-time concept was used to support real-time remote expert guidance to complete medical examinations using the ISS Human Research Facility (HRF). An American and Russian ISS crewmember received 2-hours of hands on ultrasound training 8 months prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember six days prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. Results of the CD ROM based OPE session were used to modify the instructions during a complete 35 minute real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were excellent and adequate for clinical decision-making. Complex ultrasound experiments with expert guidance were performed with high accuracy following limited pre-flight training and CD-ROM-based in-flight review, despite a 2-second communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, can facilitate the performance of complex demanding tasks.

  4. Hemostatic Effects of Microbubble-Enhanced Low-Intensity Ultrasound in a Liver Avulsion Injury Model

    PubMed Central

    Feng, Guiying; Liu, Jianhua; Zhao, Xiaochen; Wei, Jinglu; Ou, Wencai; Xiao, Shuyi; Hu, Zhiwen; Wei, Hongqin; Liu, Zheng

    2014-01-01

    Objectives Microbubble-enhanced therapeutic ultrasound (MEUS) can block the blood flow in the organs. The aim of this study was to evaluate the hemostatic effect of microbubble-enhanced pulsed, low-intensity ultrasound in a New Zealand White rabbit model of avulsion trauma of the liver. The therapeutic ultrasound (TUS) transducer was operated with the frequency of 1.2 MHz and an acoustic pressure of 3.4 MPa. Microbubble-(MB) enhanced ultrasound (MEUS) (n = 6) was delivered to the distal part of the liver where the avulsion was created. Livers were treated by TUS only (n = 4) or MB only (n = 4) which served as controls. Bleeding rates were measured and contrast enhanced ultrasound (CEUS) was performed to assess the hemostatic effect, and liver hemoperfusion before and after treatment. Generally, bleeding rates decreased more than 10-fold after the treatment with MEUS compared with those of the control group (P<0.05). CEUS showed significant declines in perfusion. The peak intensity value and the area under the curve also decreased after insonation compared with those of the control group (P<0.05). Histological examination showed cloudy and swollen hepatocytes, dilated hepatic sinusoids, perisinusoidal spaces with erythrocyte accumulation in small blood vessels, obvious hemorrhage around portal areas and scattered necrosis in liver tissues within the insonation area of MEUS Group. In addition, necrosis was found in liver tissue 48 h after insonation. We conclude that MEUS might provide an effective hemostatic therapy for serious organ trauma such as liver avulsion injury. PMID:24788757

  5. Vascular applications of contrast-enhanced ultrasound imaging.

    PubMed

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf G; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  6. A review of decision support, risk communication and patient information tools for thrombolytic treatment in acute stroke: lessons for tool developers

    PubMed Central

    2013-01-01

    Background Tools to support clinical or patient decision-making in the treatment/management of a health condition are used in a range of clinical settings for numerous preference-sensitive healthcare decisions. Their impact in clinical practice is largely dependent on their quality across a range of domains. We critically analysed currently available tools to support decision making or patient understanding in the treatment of acute ischaemic stroke with intravenous thrombolysis, as an exemplar to provide clinicians/researchers with practical guidance on development, evaluation and implementation of such tools for other preference-sensitive treatment options/decisions in different clinical contexts. Methods Tools were identified from bibliographic databases, Internet searches and a survey of UK and North American stroke networks. Two reviewers critically analysed tools to establish: information on benefits/risks of thrombolysis included in tools, and the methods used to convey probabilistic information (verbal descriptors, numerical and graphical); adherence to guidance on presenting outcome probabilities (IPDASi probabilities items) and information content (Picker Institute Checklist); readability (Fog Index); and the extent that tools had comprehensive development processes. Results Nine tools of 26 identified included information on a full range of benefits/risks of thrombolysis. Verbal descriptors, frequencies and percentages were used to convey probabilistic information in 20, 19 and 18 tools respectively, whilst nine used graphical methods. Shortcomings in presentation of outcome probabilities (e.g. omitting outcomes without treatment) were identified. Patient information tools had an aggregate median Fog index score of 10. None of the tools had comprehensive development processes. Conclusions Tools to support decision making or patient understanding in the treatment of acute stroke with thrombolysis have been sub-optimally developed. Development of tools should utilise mixed methods and strategies to meaningfully involve clinicians, patients and their relatives in an iterative design process; include evidence-based methods to augment interpretability of textual and probabilistic information (e.g. graphical displays showing natural frequencies) on the full range of outcome states associated with available options; and address patients with different levels of health literacy. Implementation of tools will be enhanced when mechanisms are in place to periodically assess the relevance of tools and where necessary, update the mode of delivery, form and information content. PMID:23777368

  7. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    PubMed

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  8. Using Ultrasound to Enhance Medical Students' Femoral Vascular Physical Examination Skills.

    PubMed

    Ahn, Justin S; French, Andrew J; Thiessen, Molly E W; Browne, Vaughn; Deutchman, Mark; Guiton, Gretchen; Madigosky, Wendy; Kendall, John L

    2015-10-01

    To determine whether the addition of ultrasound to traditional physical examination instruction improves junior medical students' abilities to locate the femoral pulse. Initially, 150 second-year medical students were taught the femoral pulse examination using traditional bedside teaching on standardized patients and online didactic videos. Students were then randomized into 2 groups: group 1 received ultrasound training first and then completed the standardized examination; and group 2 performed the standardized examination first and then received ultrasound training. On the standardized patients, the femoral artery was marked with invisible ink before the sessions using ultrasound. Compared to these markers, students were then evaluated on the accuracy of femoral artery pulse palpation and the estimated location of the femoral vein. All students completed a self-assessment survey after the ultrasound sessions. Ultrasound training improved the students' ability to palpate the femoral pulse (P= .02). However, ultrasound did not facilitate correct estimation of the femoral vein's anatomic location (P = .09). Confidence levels in localizing the femoral artery and vein were equal between groups at baseline, and both increased after the ultrasound sessions. The addition of ultrasound teaching to traditional physical examination instruction enhanced medical student competency and confidence with the femoral vascular examination. However, understanding of anatomy may require emphasis on precourse didactic material, but further study is required. © 2015 by the American Institute of Ultrasound in Medicine.

  9. The ultrasound-enhanced bioscouring performance of four polygalacturonase enzymes obtained from rhizopus oryzae

    USDA-ARS?s Scientific Manuscript database

    An analytical and statistical method has been developed to measure the ultrasound-enhanced bioscouring performance of milligram quantities of endo- and exo-polygalacturonase enzymes obtained from Rhizopus oryzae fungi. UV-Vis spectrophotometric data and a general linear mixed models procedure indic...

  10. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers.

    PubMed

    Bo, Xiao-Wan; Xu, Hui-Xiong; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-11-01

    To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer.

  11. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers

    PubMed Central

    Bo, Xiao-Wan; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-01-01

    Objective: To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. Methods: 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. Results: On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Conclusion: Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer. PMID:27626506

  12. Characteristics and Echogenicity of Clinical Ultrasound Contrast Agents: An In Vitro and In Vivo Comparison Study.

    PubMed

    Hyvelin, Jean-Marc; Gaud, Emmanuel; Costa, Maria; Helbert, Alexandre; Bussat, Philippe; Bettinger, Thierry; Frinking, Peter

    2017-05-01

    To compare physicochemical characteristics and in vitro and in vivo contrast-enhanced ultrasound imaging performance of 3 commercially available ultrasound contrast agents: SonoVue (Bracco Imaging SpA, Colleretto Giacosa, Italy; also marketed as Lumason in the USA), Definity (Lantheus Medical Imaging, North Billerica, MA) and Optison (GE Healthcare AS, Oslo, Norway). Physicochemical characteristics were measured with a Multisizer Coulter Counter (Beckman Coulter, Fullerton, CA). Two ultrasound systems (Aplio 500; Toshiba Medical Systems Corp, Tochigi-ken, Japan; and Logiq E9; GE Healthcare, Little Chalfont, England) were used with different transducers. Contrast enhancement was measured in vitro by dose-ranging measurements using a custom-built beaker setup; in vivo imaging performances were compared in pigs (heart and liver) and rabbits (liver). Quantitative analyses were performed with VueBox quantification software (Bracco Suisse SA, Plan-les-Ouates, Switzerland). Measured physicochemical characteristics were in agreement with those provided by the manufacturers. In vitro data demonstrated that the performance of SonoVue was similar to or better than that of Definity but superior to Optison (normalized scattered power 2- to 10-fold higher with SonoVue). Similar results were obtained in vivo, although the duration of enhancement in the pig heart was longer for SonoVue compared to Definity, and quantitative analysis revealed higher enhancement for SonoVue (1.5-fold increase). For liver imaging, SonoVue and Definity showed similar contrast enhancement and duration of enhancement, but compared to Optison, both peak enhancement and duration of enhancement were superior for SonoVue (up to 2-fold increase). Imaging performance of SonoVue was similar to or slightly better than that of Definity, but it was superior to Optison for the conditions used in this study. © 2017 by the American Institute of Ultrasound in Medicine.

  13. [Contrast-enhanced Ultrasound in Diagnostic Imaging of Muscle Injuries: Perfusion Imaging in the Early Arterial Phase].

    PubMed

    Hotfiel, T; Carl, H D; Swoboda, B; Engelhardt, M; Heinrich, M; Strobel, D; Wildner, D

    2016-03-01

    Ultrasound is a standard procedure widely used in the diagnostic investigation of muscle injuries and widely described in the literature. Its advantages include rapid availability, cost effectiveness and the possibility to perform a real-time dynamic examination with the highest possible spatial resolution. In the diagnostic work-up of minor lesions (muscle stiffness, muscle strain), plain ultrasound has so far been inferior to MRI. The case presented by us is an example of the possibilities offered by contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries compared with plain B-mode image ultrasound and MRI imaging of the affected region. This case report is about a high-performance football player who sustained a muscle injury. He underwent an ultrasound examination (S 2000, 9L4 Probe, Siemens, Germany), which was performed simultaneously in the conventional and contrast-enhanced mode at the level of the lesion. An intravenous bolus injection of 4.8 ml of intravascular contrast agent (SonoVue(®), Bracco, Italy) was given via a cubital intravenous line. After that, the distribution of contrast agent was visualised in the early arterial phase. In addition, a plain magnetic resonance imaging scan of both thighs was performed for reference. On conventional ultrasound, the lesion was not clearly distinguishable from neighbouring tissue, whereas contrast-enhanced ultrasound demonstrated a well delineated, circumscribed area of impaired perfusion with hypoenhancement compared with the surrounding muscles at the clinical level of the lesion in the arterial wash-in phase (0-30 sec, after intravenous administration). The MRI scan revealed an edema signal with perifascial fluid accumulation in the corresponding site. The use of intravascular contrast agent enabled the sensitive detection of a minor injury by ultrasound for the first time. An intramuscular edema seen in the MRI scan showed a functional arterial perfusion impairment on ultrasound, which was sensitively detected in the early phase. Further examinations must be performed on muscle injuries of various degrees of severity in order to validate the application of this procedure and to standardise the examination process. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Catheter-Directed Thrombolysis of Lower Limb Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pianta, Marcus J.; Thomson, Kenneth R., E-mail: k.thomson@alfred.org.au

    2011-02-15

    Late complications of thrombosis of the deep veins in the region between the popliteal vein termination and the confluence of the common iliac veins and inferior vena cava (suprapopliteal deep-vein thrombosis) are common and often unrecognized by those responsible for the initial management. Pharmacomechanical-assisted clearance of the thrombus at the time of first presentation provides the best opportunity for complete recovery with preservation of normal venous valve function and avoidance of recurrent deep-vein thrombosis and postthrombotic syndrome. Recent interventional radiology methods provide for rapid and complete thrombolysis even in some patients in whom thrombolysis was previously considered contraindicated. This reviewmore » describes the methods, safety, and efficacy of acute interventional treatment of suprapopliteal deep-vein thrombosis.« less

  15. Human Space Flight

    NASA Technical Reports Server (NTRS)

    Woolford, Barbara

    2006-01-01

    The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed just-in-time training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This just-in-time concept was used to support real-time remote expert guidance to complete medical examinations using the ISS Human Research Facility (HRF). An American md Russian ISS crewmember received 2-hours of hands on ultrasound training 8 months prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember six days prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. Results of the CD ROM based OPE session were used to modify the instructions during a complete 35 minute real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were excellent and adequate for clinical decision-making. Complex ultrasound experiments with expert guidance were performed with high accuracy following limited pre-flight training and CD-ROM-based in-flight review, despite a 2-second communication latency.

  16. Ultrasound enhances retrovirus-mediated gene transfer.

    PubMed

    Naka, Toshio; Sakoda, Tsuyoshi; Doi, Takashi; Tsujino, Takeshi; Masuyama, Tohru; Kawashima, Seinosuke; Iwasaki, Tadaaki; Ohyanagi, Mitsumasa

    2007-01-01

    Viral vector systems are efficient for transfection of foreign genes into many tissues. Especially, retrovirus based vectors integrate the transgene into the genome of the target cells, which can sustain long term expression. However, it has been demonstrated that the transduction efficiency using retrovirus is relatively lower than those of other viruses. Ultrasound was recently reported to increase gene expression using plasmid DNA, with or without, a delivery vehicle. However, there are no reports, which show an ultrasound effect to retrovirus-mediated gene transfer efficiency. Retrovirus-mediated gene transfer systems were used for transfection of 293T cells, bovine aortic endothelial cells (BAECs), rat aortic smooth muscle cells (RASMCs), and rat skeletal muscle myoblasts (L6 cells) with beta-galactosidase (beta-Gal) genes. Transduction efficiency and cell viability assay were performed on 293T cells that were exposed to varying durations (5 to 30 seconds) and power levels (1.0 watts/cm(2) to 4.0 watts/cm(2)) of ultrasound after being transduced by a retrovirus. Effects of ultrasound to the retrovirus itself was evaluated by transduction efficiency of 293T cells. After exposure to varying power levels of ultrasound to a retrovirus for 5 seconds, 293T cells were transduced by a retrovirus, and transduction efficiency was evaluated. Below 1.0 watts/cm(2) and 5 seconds exposure, ultrasound showed increased transduction efficiency and no cytotoxicity to 293T cells transduced by a retrovirus. Also, ultrasound showed no toxicity to the virus itself at the same condition. Exposure of 5 seconds at the power of 1.0 watts/cm(2) of an ultrasound resulted in significant increases in retrovirus-mediated gene expression in all four cell types tested in this experiment. Transduction efficiencies by ultrasound were enhanced 6.6-fold, 4.8-fold, 2.3-fold, and 3.2-fold in 293T cells, BAECs, RASMCs, and L6 cells, respectively. Furthermore, beta-Gal activities were also increased by the retrovirus with ultrasound exposure in these cells. Adjunctive ultrasound exposure was associated with enhanced retrovirus-mediated transgene expression in vitro. Ultrasound associated local gene therapy has potential for not only plasmid-DNA-, but also retrovirus-mediated gene transfer.

  17. Optical tomography of fluorophores in dense scattering media based on ultrasound-enhanced chemiluminescence

    NASA Astrophysics Data System (ADS)

    Kobayashi, Masaki; Kikuchi, Naoto; Sato, Akihiro

    2015-01-01

    This letter proposes and demonstrates ultrasound-combined optical imaging in dense scattering media. A peroxyoxalate chemiluminescence system that includes fluorophores to chemically excite the pigment is stimulated by ultrasound irradiation with power of less than 0.14 W/cm2. Using focused ultrasound, the chemiluminescence is selectively spatially enhanced, which leads to imaging of the pigment when embedded in a light-scattering medium via scanning of the focal point. The ultrasonically enhanced intensity of the chemiluminescence depends on the base intensity of the chemiluminescence without the applied ultrasound irradiation, which thereby enables quantitative determination of the fluorophore concentration. The authors demonstrate the potential of this method to resolve chemiluminescent targets in a dense scattering medium that is comparable to biological tissue. An image was acquired of a chemiluminescent target that included indocyanine green as the fluorophore embedded at a depth of 20 mm in an Intralipid-10% 200 ml/l solution scattering medium (the reduced scattering coefficient was estimated to be approximately 1.3 mm-1), indicating the potential for expansion of this technique for use in biological applications.

  18. Is ultrasound perfusion imaging capable of detecting mismatch? A proof-of-concept study in acute stroke patients.

    PubMed

    Reitmeir, Raluca; Eyding, Jens; Oertel, Markus F; Wiest, Roland; Gralla, Jan; Fischer, Urs; Giquel, Pierre-Yves; Weber, Stefan; Raabe, Andreas; Mattle, Heinrich P; Z'Graggen, Werner J; Beck, Jürgen

    2017-04-01

    In this study, we compared contrast-enhanced ultrasound perfusion imaging with magnetic resonance perfusion-weighted imaging or perfusion computed tomography for detecting normo-, hypo-, and nonperfused brain areas in acute middle cerebral artery stroke. We performed high mechanical index contrast-enhanced ultrasound perfusion imaging in 30 patients. Time-to-peak intensity of 10 ischemic regions of interests was compared to four standardized nonischemic regions of interests of the same patient. A time-to-peak >3 s (ultrasound perfusion imaging) or >4 s (perfusion computed tomography and magnetic resonance perfusion) defined hypoperfusion. In 16 patients, 98 of 160 ultrasound perfusion imaging regions of interests of the ischemic hemisphere were classified as normal, and 52 as hypoperfused or nonperfused. Ten regions of interests were excluded due to artifacts. There was a significant correlation of the ultrasound perfusion imaging and magnetic resonance perfusion or perfusion computed tomography (Pearson's chi-squared test 79.119, p < 0.001) (OR 0.1065, 95% CI 0.06-0.18). No perfusion in ultrasound perfusion imaging (18 regions of interests) correlated highly with diffusion restriction on magnetic resonance imaging (Pearson's chi-squared test 42.307, p < 0.001). Analysis of receiver operating characteristics proved a high sensitivity of ultrasound perfusion imaging in the diagnosis of hypoperfused area under the curve, (AUC = 0.917; p < 0.001) and nonperfused (AUC = 0.830; p < 0.001) tissue in comparison with perfusion computed tomography and magnetic resonance perfusion. We present a proof of concept in determining normo-, hypo-, and nonperfused tissue in acute stroke by advanced contrast-enhanced ultrasound perfusion imaging.

  19. Accuracy of contrast-enhanced ultrasound in the detection of bladder cancer

    PubMed Central

    Nicolau, C; Bunesch, L; Peri, L; Salvador, R; Corral, J M; Mallofre, C; Sebastia, C

    2011-01-01

    Objective To assess the accuracy contrast-enhanced ultrasound (CEUS) in bladder cancer detection using transurethral biopsy in conventional cystoscopy as the reference standard and to determine whether CEUS improves the bladder cancer detection rate of baseline ultrasound. Methods 43 patients with suspected bladder cancer underwent conventional cystoscopy with transurethral biopsy of the suspicious lesions. 64 bladder cancers were confirmed in 33 out of 43 patients. Baseline ultrasound and CEUS were performed the day before surgery and the accuracy of both techniques for bladder cancer detection and number of detected tumours were analysed and compared with the final diagnosis. Results CEUS was significantly more accurate than ultrasound in determining presence or absence of bladder cancer: 88.37% vs 72.09%. Seven of eight uncertain baseline ultrasound results were correctly diagnosed using CEUS. CEUS sensitivity was also better than that of baseline ultrasound per number of tumours: 65.62% vs 60.93%. CEUS sensitivity for bladder cancer detection was very high for tumours larger than 5 mm (94.7%) but very low for tumours <5 mm (20%) and also had a very low negative predictive value (28.57%) in tumours <5 mm. Conclusion CEUS provided higher accuracy than baseline ultrasound for bladder cancer detection, being especially useful in non-conclusive baseline ultrasound studies. PMID:21123306

  20. Effects of low-frequency ultrasound on heterogenous deacetylation of chitin.

    PubMed

    Ngo, Thi Hoai Duong; Ngo, Dang Nghia

    2017-11-01

    The effects of low frequency ultrasound to the heterogeneous deacetylation of chitin from the shell of white shrimp (Penaeus vannamei) were examined. The deacetylation process was carried out in the range of NaOH concentrations from 35% to 65% (w/w) with and without the ultrasound in the frequency of 37kHz, RMS=300W. The chitosan obtained was characterized in the degree of deacetylation, solubility, FT-IR and X-ray diffraction. The results showed that the behaviors of the deacetylation in two cases, with and without ultrasound, were similar but the ultrasound enhanced the deacetylation rate and therefore reduced the time of the reaction to get the same degree of deacetylation. The role of ultrasound in the process showed more clearly in the low concentration of sodium hydroxide, below 45% (w/w). At the higher concentration of sodium hydroxide, the influence of ultrasound on facilitating deacetylation decreased significantly, however, ultrasound was still keeping on its improving effect on the solubility of the chitosan obtained. The data from FT-IR and X-ray diffraction did not show any considerable change in structure of both kinds of chitosan. This study showed the potential of using low frequency ultrasound in enhancing the deacetylation of chitin for reducing the chemical consumption. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Using low-frequency ultrasound to improve the optical clearing of porcine skin

    NASA Astrophysics Data System (ADS)

    Zhong, Huiqing; Guo, Zhouyi; Wei, Huajiang; Zhang, Zude; Zeng, Changchun; Zhai, Juan; He, Yonghong

    2008-12-01

    The glycerol used as an enhancer for tissue optical clearing technique has been researched. However, using it and a physical way of ultrasound enhance optical clearing of tissue reported a few. We researched that the ultrasound whether can improve the optical clearing of dealt with 80% glycerol tissue. The fresh porcine skins divided into four groups. The first group was not dealt with by ultrasound and 80% glycerol, the second group was dealt with by only ultrasound, the third group was dealt with by 80% glycerol and no by ultrasound, and the fourth group was dealt with by both 80% glycerol and ultrasound. And we measured changes in optical scattering of the porcine skins under treatment with OCT. From the OCT images show that the fourth group changed very faster than the other's during the 0~15 min. And it can be clearly seen that there is a significant improvement in the light penetration depth and imaging contrast in a shorter time. It is possible that the low-frequency ultrasound can make disordering of the stratum corneum lipids of the porcine skin (because the cavitation has happened), and improve the speed of 80% glycerol through the stratum corneum of skin. These results proved that using 80% glycerol with the ultrasound can better improve the optical clearing of tissue.

  2. Ultrasound-enhanced delivery of doxorubicin/all-trans retinoic acid-loaded nanodiamonds into tumors.

    PubMed

    Li, Huanan; Zeng, Deping; Wang, Zhenyu; Fang, Liaoqiong; Li, Faqi; Wang, Zhibiao

    2018-03-14

    To build up a combined therapy strategy to address limitations of the enhanced permeability and retention (EPR) effect and improve the efficiency of tumor therapy. A pH-sensitive nanocomplex for co-delivery of doxorubicin (DOX) and all-trans retinoic acid (ATRA) was developed based on nanodiamonds (DOX/ATRA-NDs) to enhance intracellular retention of drugs. Meanwhile, ultrasound was employed to enhance tumor vascular penetration of DOX-ATRA-NDs. The distribution of DOX/ATRA-NDs in the tumor tissues increased threefold when ultrasound was applied at 1 MHz and 0.6 W/cm 2 . Comparing with unmodified chemotherapeutics, the combined therapy induced more tumor cells apoptosis and greater tumor growth inhibition in both liver and breast tumor models. DOX-ATRA-NDs demonstrate great potential in clinical applications.

  3. [Prehospital thrombolysis: A national perspective. Pharmaco-invasive strategy for early reperfusion of STEMI in Mexico].

    PubMed

    Arriaga-Nava, Roberto; Valencia-Sánchez, Jesús-Salvador; Rosas-Peralta, Martin; Garrido-Garduño, Martin; Calderón-Abbo, Moisés

    2015-01-01

    To review the existing evidence on the role of prehospital thrombolysis in patients with ST-segment elevation acute myocardial infarction (STEMI) as part of a strategy of cutting edge to reduce the time of coronary reperfusion and as a consequence improves both the survival and function. We used the technique of exploration-reduction-evaluation-analysis and synthesis of related studies, with an overview of current recommendations, data from controlled clinical trials and from the national and international registries about the different strategies for STEMI reperfusion. In total, we examined 186 references on prehospital thrombolysis, 130 references in times door-treatment, 139 references in STEMI management and national and international registries as well as 135 references on rescue and primary percutaneous coronary intervention for STEMI. Finally the 48 references that were more relevant and informative were retained. The «time» factor is crucial in the success of early reperfusion in STEMI especially if thrombolysis is applied correctly during the prehospital time. The primary percutaneous coronary intervention is contingent upon its feasibility before 120 min from the onset of symptoms. In our midst to internationally, thrombolysis continues to be a strategy with great impact on their expectations of life and function of patients. Telecommunication systems should be incorporate in real time to the priority needs of catastrophic diseases such as STEMI where life is depending on time. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  4. Cost-effectiveness of optimizing acute stroke care services for thrombolysis.

    PubMed

    Penaloza-Ramos, Maria Cristina; Sheppard, James P; Jowett, Sue; Barton, Pelham; Mant, Jonathan; Quinn, Tom; Mellor, Ruth M; Sims, Don; Sandler, David; McManus, Richard J

    2014-02-01

    Thrombolysis in acute stroke is effective up to 4.5 hours after symptom onset but relies on early recognition, prompt arrival in hospital, and timely brain scanning. This study aimed to establish the cost-effectiveness of increasing thrombolysis rates through a series of hypothetical change strategies designed to optimize the acute care pathway for stroke. A decision-tree model was constructed, which relates the acute management of patients with suspected stroke from symptom onset to outcome. Current practice was modeled and compared with 7 change strategies designed to facilitate wider eligibility for thrombolysis. The model basecase consisted of data from consenting patients following the acute stroke pathway recruited in participating hospitals with data on effectiveness of treatment and costs from published sources. All change strategies were cost saving while increasing quality-adjusted life years gained. Using realistic estimates of effectiveness, the change strategy with the largest potential benefit was that of better recording of onset time, which resulted in 3.3 additional quality-adjusted life years and a cost saving of US $46,000 per 100,000 population. All strategies increased the number of thrombolysed patients and the number requiring urgent brain imaging (by 9% to 21% dependent on the scenario). Assuming a willingness-to-pay of US $30,000 per quality-adjusted life year gained, the potential budget available to deliver the interventions in each strategy ranged from US $50,000 to US $144,000. These results suggest that any strategy that increases thrombolysis rates will result in cost savings and improved patient quality of life. Healthcare commissioners could consider this model when planning improvements in stroke care.

  5. Thrombolytic utilization for ischemic stroke in US hospitals with neurology residency program.

    PubMed

    Moradiya, Yogesh; Crystal, Howard; Valsamis, Helen; Levine, Steven R

    2013-12-03

    We aimed to compare the rates of thrombolysis utilization for acute ischemic stroke in hospitals with neurology residency (NR) to those of other teaching (OT) and nonteaching (NT) hospitals. A retrospective serial cross-sectional cohort study of a nationally representative sample of stroke patients was conducted. Accreditation Council for Graduate Medical Education-accredited NR program-affiliated hospitals in the United States were cross-matched to the hospitals in the Nationwide Inpatient Sample from 2000 to 2010. ICD-9-CM codes were used for case ascertainment. A total of 712,433 adult ischemic stroke patients from 6,839 hospital samples were included, of whom 10.1%, 29.1%, and 60.8% were treated in NR, OT, and NT hospitals, respectively. Stroke patients in NR received thrombolysis more frequently (3.74% ± 0.24% [standard error]) than in OT (2.28% ± 0.11%, p < 0.001) and NT hospitals (1.44% ± 0.06%, p < 0.001). The adjusted odds ratios (ORs) of thrombolysis rates in NR vs OT and NR vs NT increased with each decade increment in age. In multivariate analysis, NR was independently predictive of higher thrombolysis rate (adjusted OR 1.51; 95% confidence interval [CI] 1.44-1.59 [NR vs OT], and adjusted OR 1.82; 95% CI 1.73-1.91 [NR vs NT]). Acute stroke care in NR hospitals is associated with an increased thrombolytic utilization. The disparities between the thrombolysis rate in NR and that in OT and NT hospitals are greater among elderly patients.

  6. Thrombolytic utilization for ischemic stroke in US hospitals with neurology residency program

    PubMed Central

    Crystal, Howard; Valsamis, Helen; Levine, Steven R.

    2013-01-01

    Objective: We aimed to compare the rates of thrombolysis utilization for acute ischemic stroke in hospitals with neurology residency (NR) to those of other teaching (OT) and nonteaching (NT) hospitals. Methods: A retrospective serial cross-sectional cohort study of a nationally representative sample of stroke patients was conducted. Accreditation Council for Graduate Medical Education–accredited NR program–affiliated hospitals in the United States were cross-matched to the hospitals in the Nationwide Inpatient Sample from 2000 to 2010. ICD-9-CM codes were used for case ascertainment. Results: A total of 712,433 adult ischemic stroke patients from 6,839 hospital samples were included, of whom 10.1%, 29.1%, and 60.8% were treated in NR, OT, and NT hospitals, respectively. Stroke patients in NR received thrombolysis more frequently (3.74% ± 0.24% [standard error]) than in OT (2.28% ± 0.11%, p < 0.001) and NT hospitals (1.44% ± 0.06%, p < 0.001). The adjusted odds ratios (ORs) of thrombolysis rates in NR vs OT and NR vs NT increased with each decade increment in age. In multivariate analysis, NR was independently predictive of higher thrombolysis rate (adjusted OR 1.51; 95% confidence interval [CI] 1.44–1.59 [NR vs OT], and adjusted OR 1.82; 95% CI 1.73–1.91 [NR vs NT]). Conclusions: Acute stroke care in NR hospitals is associated with an increased thrombolytic utilization. The disparities between the thrombolysis rate in NR and that in OT and NT hospitals are greater among elderly patients. PMID:24186911

  7. Disruption of Prostate Microvasculature by Combining Microbubble-Enhanced Ultrasound and Prothrombin

    PubMed Central

    Liu, Yongliang; Qiao, Lu; Gao, Wenhong; Zhang, Weiguo; Liu, Zheng

    2016-01-01

    Previous studies have shown a unique method to disrupt tumor vasculature using pulsed, high-pressure amplitude therapeutic ultrasound combined with microbubbles. In this study, we attempted to destroy the prostate vasculature of canine prostates using microbubble-enhanced ultrasound (MEUS) and prothrombin. The prostates of 43 male mongrel canines were surgically exposed. Twenty-two prostates were treated using MEUS (n = 11) or MEUS and prothrombin (PMEUS, n = 11). The other 21 prostates, which were treated using microbubbles (n = 7), ultrasound (n = 7) or prothrombin (n = 7) only, served as the controls. Prothrombin was intravenously infused at 20 IU/kg. MEUS was induced using a therapeutic ultrasound device at a peak negative pressure of 4.47 MPa and a microbubble injection. Contrast-enhanced ultrasound was performed to assess the blood perfusion of the prostates. Then, the prostate tissue was harvested immediately after treatment and at 48 hours later for pathological examination. The contrast-enhanced ultrasound peak value of the prostate decreased significantly from 36.2 ± 5.6 to 27.1 ± 6.3 after treatment in the PMEUS group, but it remained unchanged in the other groups. Histological examination found severe microvascular rupture, hemorrhage and thrombosis in both MEUS- and PMEUS-treated prostates immediately after treatment, while disruption in the PMEUS group was more severe than in the MEUS group. Forty-eight hours after treatment, massive necrosis and infiltration of white blood cells occurred in the PMEUS group. This study demonstrated that PMEUS disrupted the normal microvasculature of canine prostates and induced massive necrosis. PMEUS could potentially become a new noninvasive method used for the treatment of benign prostatic hyperplasia. PMID:27643992

  8. Pulsed cavitational therapy using high-frequency ultrasound for the treatment of deep vein thrombosis in an in vitro model of human blood clot

    NASA Astrophysics Data System (ADS)

    Goudot, G.; Mirault, T.; Arnal, B.; Boisson-Vidal, C.; Le Bonniec, B.; Gaussem, P.; Galloula, A.; Tanter, M.; Messas, E.; Pernot, M.

    2017-12-01

    Post-thrombotic syndrome, a frequent complication of deep venous thrombosis, can be reduced with early vein recanalization. Pulsed cavitational therapy (PCT) using ultrasound is a recent non-invasive approach. We propose to test the efficacy and safety of high-frequency focused PCT for drug-free thrombolysis (thrombotripsy) in a realistic in vitro model of venous thrombosis. To reproduce venous thrombosis conditions, human whole blood was allowed to clot by stasis in silicone tubes (6 mm internal diameter) at a 30 cm H2O pressure, maintained during the whole experiment. We engineered an ultrasound device composed of dual 2.25 MHz transducers centered around a 6 MHz imaging probe. A therapeutic focus was generated at a 3.2 cm depth from the probe. Thrombotripsy was performed by longitudinally scanning the thrombus at three different speeds: 1 mm s-1 (n  =  6) 2 mm s-1 (n  =  6) 3 mm s-1 (n  =  12). Restored outflow was measured every three passages. Filters were placed to evaluate the debris size. Twenty-four occlusive thrombi, of 2.5 cm mean length and 4.4 kPa mean stiffness, were studied. Flow restoration was systematically obtained by nine subsequent passages (4.5 min maximum). By varying the device’s speed, we found an optimal speed of 1 mm s-1 to be efficient for effective recanalization with 90 s (three passages). Within 90 s, flow restoration was of 80, 62 and 74% at respectively 1, 2 and 3 mm s-1. For all groups, cavitation cloud drilled a 1.7 mm mean diameter channel throughout the clot. Debris analysis showed 92% of debris  <10 µm, with no fragment  >  200 µm.

  9. Enhanced Ultrasound Visualization of Bracytherapy Seeds by a Novel Magnetically Induced Motion Imaging Method

    DTIC Science & Technology

    2008-04-01

    We report our progress in developing Magnetically Induced Motion Imaging (MIMI) for unambiguous identification and localization brachytherapy seeds ...in ultrasound images. Coupled finite element and ultrasound imaging simulations have been performed to demonstrate that seeds are detectable with MIMI

  10. Sonodynamic therapy--a review of the synergistic effects of drugs and ultrasound.

    PubMed

    Rosenthal, Ionel; Sostaric, Joe Z; Riesz, Peter

    2004-09-01

    Sonodynamic therapy, the ultrasound dependent enhancement of cytotoxic activities of certain compounds (sonosensitizers) in studies with cells in vitro and in tumor bearing animals, is reviewed. The attractive features of this modality for cancer treatment emerges from the ability to focus the ultrasound energy on malignancy sites buried deep in tissues and to locally activate a preloaded sonosensitizer. Possible mechanisms of sonodynamic therapy include generation of sonosensitizer derived radicals which initiate chain peroxidation of membrane lipids via peroxyl and/or alkoxyl radicals, the physical destabilization of the cell membrane by the sonosensitizer thereby rendering the cell more susceptible to shear forces or ultrasound enhanced drug transport across the cell membrane (sonoporation). Evidence against the role of singlet oxygen in sonodynamic therapy is discussed. The mechanism of sonodynamic therapy is probably not governed by a universal mechanism, but may be influenced by multiple factors including the nature of the biological model, the sonosensitizer and the ultrasound parameters. The current review emphasizes the effect of ultrasound induced free radicals in sonodynamic therapy.

  11. Numerical Study on Focusing of Ultrasounds in Microbubble-enhanced HIFU

    NASA Astrophysics Data System (ADS)

    Matsumoto, Yoichiro; Okita, Kohei; Takagi, Shu

    2011-11-01

    The injection of microbubbles into the target tissue enhances tissue heating in High-Intensity Focused Ultrasound therapy, via inertial cavitation. The control of the inertial cavitation is required to achieve the efficient tissue ablation. Microbubbles between a transducer and a target disturb the ultrasound propagation depending on the conditions. A method to clear such microbubbles has been proposed by Kajiyama et al. [Physics Procedia 3 (2010) 305-314]. In the method, the irradiation of intense ultrasounds with a burst waveform fragmentize microbubbles in the pathways before the irradiation of ultrasounds for tissue heating. The vitro experiment using a gel containing microbubbles has showed that the method enables to heat the target correctly by controlling the microbubble distribution. Following the experiment, we simulate the focusing of ultrasounds through a mixture containing microbubbles with considering the size and number density distributions in space. The numerical simulation shows that the movement of the heating region from the transducer side to the target by controlling the microbubble distributions. The numerical results elucidate well the experimental ones.

  12. Laser-enhanced thermal effect of moderate intensity focused ultrasound on bio-tissues

    NASA Astrophysics Data System (ADS)

    Zhao, JinYu; Zhang, ShuYi; Shui, XiuJi; Fan, Li

    2017-09-01

    For avoiding extra-damage to healthy tissues surrounding the focal point during high intensity focused ultrasound (HIFU) treatment in medical therapy, to reduce the ultrasonic intensity outside the focal point is expected. Thus, the heating processes induced by moderate intensity focused ultrasound (MIFU) and enhanced by combined irradiation of laser pulses for bio-tissues are studied in details. For fresh bio-tissues, the enhanced thermal effects by pulsed laser combined with MIFU irradiation are observed experimentally. To explore the mechanisms of these effects, several tissue-mimicking materials composed of agar mixed with graphite powders are prepared and studied for comparison, but the laser-enhanced thermal effects in these mimicking materials are much less than that in the fresh bio-tissues. Therefore, it is suggested that the laser-enhanced thermal effects may be mainly attributed to bio-activities and related photo-bio-chemical effects of fresh tissues.

  13. Ultrasound-mediated microbubble enhancement of radiation therapy studied using three-dimensional high-frequency power Doppler ultrasound.

    PubMed

    Kwok, Sheldon J J; El Kaffas, Ahmed; Lai, Priscilla; Al Mahrouki, Azza; Lee, Justin; Iradji, Sara; Tran, William Tyler; Giles, Anoja; Czarnota, Gregory J

    2013-11-01

    Tumor responses to high-dose (>8 Gy) radiation therapy are tightly connected to endothelial cell death. In the study described here, we investigated whether ultrasound-activated microbubbles can locally enhance tumor response to radiation treatments of 2 and 8 Gy by mechanically perturbing the endothelial lining of tumors. We evaluated vascular changes resulting from combined microbubble and radiation treatments using high-frequency 3-D power Doppler ultrasound in a breast cancer xenograft model. We compared treatment effects and monitored vasculature damage 3 hours, 24 hours and 7 days after treatment delivery. Mice treated with 2 Gy radiation and ultrasound-activated microbubbles exhibited a decrease in vascular index to 48 ± 10% at 24 hours, whereas vascular indices of mice treated with 2 Gy radiation alone or microbubbles alone were relatively unchanged at 95 ± 14% and 78 ± 14%, respectively. These results suggest that ultrasound-activated microbubbles enhance the effects of 2 Gy radiation through a synergistic mechanism, resulting in alterations of tumor blood flow. This novel therapy may potentiate lower radiation doses to preferentially target endothelial cells, thus reducing effects on neighboring normal tissue and increasing the efficacy of cancer treatments. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  14. Thrombolysis in the air. Air-ambulance paramedics flying to remote communities treat patients before hospitalization.

    PubMed Central

    Kapasi, H.; Kelly, L.; Morgan, J.

    2000-01-01

    PROBLEM ADDRESSED: First Nations* communities in the North have a high prevalence of coronary artery disease and type 2 diabetes and face an increasing incidence of myocardial infarction (MI). Many conditions delay timely administration of thrombolysis, including long times between when patients first experience symptoms and when they present to community nursing stations, delays in air transfers to treating hospitals, uncertainty about when planes are available, and poor flying conditions. OBJECTIVE OF PROGRAM: To develop a program for administration of thrombolysis on the way to hospital by air ambulance paramedics flying to remote communities to provide more rapid thrombolytic therapy to northern patients experiencing acute MIs. COMPONENTS OF PROGRAM: Critical care flight paramedics fly to northern communities from Sioux Lookout, Ont; assess patients; communicate with base hospital physicians; review an exclusion criteria checklist; and administer thrombolytics according to the Sioux Lookout District Health Centre/Base Hospital Policy and Procedure Manual. Patients are then flown to hospitals in Sioux Lookout; Winnipeg, Man; or Thunder Bay, Ont. CONCLUSION: This thrombolysis program is being pilot tested, and further evaluation and development is anticipated. Images p1316-a p1317-a p1317-b PMID:10907571

  15. [Prehospital care of patients with acute ST elevation myocardial infarction].

    PubMed

    Arntz, Hans-Richard

    2005-12-01

    Symptomatic prehospital therapy of patients suffering from an ST elevation myocardial infarction basically does not differ from in-hospital care regarding pain relief, beta-blockers, antiplatelets, and thrombin antagonists as well as therapy of elevated blood pressure and acute heart failure. Precondition of a targeted and adequate treatment, however, is the twelve-lead ECG whose reliability does not differ from the ECG in the hospital. Biomarkers have no role in the prehospital setting. Out-of-hospital thrombolysis, which has been proven to be superior to later in-hospital initiation, can be used as a safe strategy for reperfusion. Only the prehospital phase offers a chance to treat the majority of patients within the first 2 h after symptom onset, a time window where thrombolysis results in equal or even better outcomes with respect to mortality, if compared to percutaneous intervention. Therefore, prehospital thrombolysis should be routinely applied in areas with a weak infrastructure and few and less experienced facilities for intervention but should also be considered a principal way for earliest start of reperfusion therapy. There is increasing evidence supporting the "rescue PCI" concept in patients in whom thrombolysis has failed. By contrast, the role of "facilitated PCI" still has to be defined.

  16. Disruption of tumor neovasculature by microbubble enhanced ultrasound: a potential new physical therapy of anti-angiogenesis.

    PubMed

    Liu, Zheng; Gao, Shunji; Zhao, Yang; Li, Peijing; Liu, Jia; Li, Peng; Tan, Kaibin; Xie, Feng

    2012-02-01

    Tumor angiogenesis is of vital importance to the growth and metastasis of solid tumors. The angiogenesis is featured with a defective, leaky and fragile vascular construction. Microbubble enhanced ultrasound (MEUS) cavitation is capable of mechanical disruption of small blood vessels depending on effective acoustic pressure amplitude. We hypothesized that acoustic cavitation combining high-pressure amplitude pulsed ultrasound (US) and circulating microbubble could potentially disrupt tumor vasculature. A high-pressure amplitude, pulsed ultrasound device was developed to induce inertial cavitation of circulating microbubbles. The tumor vasculature of rat Walker 256 was insonated percutaneously with two acoustic pressures, 2.6 MPa and 4.8 MPa, both with intravenous injection of a lipid microbubble. The controls were treated by the ultrasound only or sham ultrasound exposure. Contrast enhanced ultrasound (CEUS) and histology were performed to assess tumor circulation and pathological changes. The CEUS results showed that the circulation of Walker 256 tumors could be completely blocked off for 24 hours in 4.8 MPa treated tumors. The CEUS gray scale value (GSV) indicated that there was significant GSV drop-off in both of the two experimental groups but none in the controls. Histology showed that the tumor microvasculature was disrupted into diffuse hematomas accompanied by thrombosis, intercellular edema and multiple cysts formation. The 24 hours of tumor circulation blockage resulted in massive necrosis of the tumor. MEUS provides a new, simple physical method for anti-angiogenic therapy and may have great potential for clinical applications. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Relapses in three patients with Takayasu arteritis under tocilizumab treatment detected by contrast enhanced ultrasound.

    PubMed

    Czihal, Michael; Lottspeich, Christian; Schröttle, Angelika; Treitl, Karla Maria; Treitl, Marcus; Leipe, Jan; Schulze-Koops, Hendrik; Hoffmann, Ulrich; Dechant, Claudia

    2018-02-01

    Takayasu arteritis (TA) is a rare large vessel vasculitis, affecting the aorta and its major branches, typically in young women. In this case report, we present three cases of young women of Caucasian descent who experienced relapses while under treatment with the monoclonal humanized antibody to the interleukin 6 receptor, tocilizumab. Active vasculitic lesions of the supraaortic (common carotid and axillary) arteries were detected and characterized via high resolution contrast enhanced ultrasound. Based on these cases, we discuss the potential role of contrast enhanced ultrasound in the diagnosis and follow-up of TA as well as the current data on the efficacy of tocilizumab in the treatment of TA.

  18. Longitudinal Ultrasound Education Track Curriculum Implemented Within an Emergency Medicine Residency Program.

    PubMed

    Boulger, Creagh; Adams, Daniel Z; Hughes, Daralee; Bahner, David P; King, Andrew

    2017-06-01

    Emergency Medicine residency programs offer ultrasound-focused curricula to address Accreditation Council for Graduate Medical Education (ACGME) milestones. Although some programs offer advanced clinical tracks in ultrasound, no standard curriculum exists. We sought to establish a well-defined ultrasound track curriculum to allow interested residents to develop advanced clinical skills and scholarship within this academic niche. The curriculum involves a greater number of clinical scans, ultrasound-focused scholarly and quality improvement projects, enhanced faculty-driven ultrasound focused didactics, and participation at a national ultrasound conference to receive certification. Successful ultrasound scholarly tracks can provide residents with the potential to obtain fellowships or competency beyond ACGME requirements. © 2017 by the American Institute of Ultrasound in Medicine.

  19. Combined Pharmacomechanical Thrombolysis of Complete Portomesenteric Thrombosis in a Liver Transplant Recipient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lorenz, Jonathan M., E-mail: jlorenz@radiology.bsd.uchicago.edu; Bennett, Shelby; Patel, Jay

    2013-01-30

    Treatment options for portomesenteric venous thrombosis range from anticoagulation to surgery, depending on chronicity, severity of symptoms, extent of thrombosis, and the availability of local expertise. For acute and subacute cases, a variety of endovascular options have been described in limited published series and case reports, including thrombolysis and mechanical thrombectomy. We report what is to our knowledge the first case in which the Trellis pharmacomechanical thrombolysis device was used successfully to treat complete acute thrombosis of the entire superior mesenteric vein and the entire portal vein with extension into all segmental intrahepatic portal branches in a young adult aftermore » liver transplantation. This device, coupled with adjunctive techniques using balloon catheters, facilitated complete restoration of flow, resulting in graft salvage and long-term patency.« less

  20. Ultrasound enhanced sanitizer efficacy in reduction of Escherichia coli O157:H7 population on spinach leaves

    USDA-ARS?s Scientific Manuscript database

    The use of ultrasound to enhance the efficacy of selected sanitizers in reduction of Escherichia coli O157:H7 populations on spinach was investigated. Spot-inoculated spinach samples were treated with water, chlorine, acidified sodium chlorite (ASC), peroxyacetic acid (POAA), and acidic electrolyzed...

  1. Endoscopic ultrasound: state-of-the-art GI tumor staging

    NASA Astrophysics Data System (ADS)

    Trowers, Eugene A.

    1999-06-01

    Videoendoscopy has truly enlarged the scope of diagnostic and therapeutic gastroenterology. However, videoendoscopic examinations are limited to the mucosal surface. Endoscopic ultrasound allows the endoscopist a view beyond the intestinal wall which opens the door to a variety of new gastroenterologic techniques. The evaluation of plain images in combination with contrast-enhanced imags has been found to be helpful when applied to CT and MRI. A similar advantage may be found for endoscopic ultrasound (EUS) studies. The efficacy of EUS with and without contrast enhancement is critically reviewed.

  2. Perfusion computed tomography-guided intravenous thrombolysis for acute ischemic stroke beyond 4.5 hours: a case-control study.

    PubMed

    García-Bermejo, Pablo; Calleja, Ana I; Pérez-Fernández, Santiago; Cortijo, Elisa; del Monte, José M; García-Porrero, Miguel; Fe Muñoz, M; Fernández-Herranz, Rosario; Arenillas, Juan F

    2012-01-01

    Extending the therapeutic window of intravenous thrombolysis for acute ischemic stroke beyond the established 4.5-hour limit is of critical importance in order to increase the proportion of thrombolysed stroke patients. In this setting, the capacity of MRI to select acute stroke patients for reperfusion therapies in delayed time windows has been and is being tested in clinical trials. However, whether the more available and cost-effective perfusion computed tomography (PCT) may be useful to select candidates for delayed intravenous thrombolysis remains largely unexplored. We aimed to evaluate the safety and efficacy of PCT-guided intravenous thrombolysis beyond 4.5 h after stroke onset. We prospectively studied all consecutive acute ischemic stroke patients treated with intravenous tissue plasminogen activator (tPA) in our stroke unit between January 2008 and December 2010. Patients treated within 0- 4.5 h were treated according to non-contrast CT (NCCT) criteria. Beyond 4.5 h, patients received intravenous tPA according to PCT criteria, i.e. an infarct core on cerebral blood volume (CBV) maps not exceeding one third of the middle cerebral artery (MCA) territory and tissue at risk as defined by mean transit time-CBV mismatch greater than 20%. Predetermined primary endpoints were symptomatic hemorrhagic transformation and favorable long-term outcome, while early neurological improvement and MCA recanalization were considered secondary endpoints. Statistical analysis included bivariate comparisons between the two groups for each endpoint and logistic regression models when significance was found in bivariate analyses. This study was approved by our local ethics committee. A total of 245 patients received intravenous thrombolysis. After the groups were matched by baseline National Institutes of Health Stroke Scale score, 172 patients treated at <4.5 h and 43 patients treated at >4.5 h were finally included. Early and late groups were comparable regarding baseline variables; only cardioembolic etiology was more frequent in the >4.5 h group. Rates of symptomatic hemorrhagic transformation (2.9% in the <4.5 h group vs. 2.3% in the >4.5 h group; p = 1.0) and good long-term outcome (64.5 vs. 60.5%, respectively; p = 0.620) were similar between the groups. However, delayed intravenous thrombolysis was independently associated with a worse early clinical course [odds ratio (OR) 2.07, 95% confidence interval (CI) 1.04-4.1; p = 0.038] and lower 2-hour MCA recanalization rates (OR 0.4, 95% CI 0.17-0.92; p = 0.03). Primary safety and efficacy endpoints were comparable between the early and delayed thrombolysis groups. The results of our exploratory study may justify a randomized clinical trial to test the safety and efficacy of PCT-guided intravenous thrombolysis in acute ischemic stroke patients presenting beyond 4.5 h from symptom onset. Copyright © 2012 S. Karger AG, Basel.

  3. Transdermal delivery of lercanidipine hydrochloride: effect of chemical enhancers and ultrasound.

    PubMed

    Shetty, Pallavi K; Suthar, Neelam A; Menon, Jyothsna; Deshpande, Praful B; Avadhani, Kiran; Kulkarni, Raghavendra V; Mutalik, Srinivas

    2013-08-01

    The effects of permeation enhancers and sonophoresis on the transdermal permeation of lercanidipine hydrochloride (LRDP) across mouse skin were investigated. Parameters including drug solubility, partition coefficient, drug degradation and drug permeation in skin were determined. Tween-20, dimethyl formamide, propylene glycol, poly ethylene glycol (5% v/v) and different concentration of ethanol were used for permeation enhancement. Low frequency ultrasound was also applied in the presence and absence of permeation enhancers to assess its effect on augmenting the permeation of drug. All the permeation enhancers, except propylene glycol, increased the transdermal permeation of LRDP. Sonophoresis significantly increased the cumulative amount of LRDP permeating through the skin in comparison to passive diffusion. A synergistic effect was noted when sonophoresis was applied in presence of permeation enhancers. The results suggest that the formulation of LRDP with an appropriate penetration enhancer may be useful in the development of a therapeutic system to deliver LRDP across the skin for a prolonged period (i.e., 24 h). The application of ultrasound in association with permeation enhancers could further serve as non-oral and non-invasive drug delivery modality for the immediate therapeutic effect.

  4. Enhancement of mass transfer by ultrasound: Application to adsorbent regeneration and food drying/dehydration.

    PubMed

    Yao, Ye

    2016-07-01

    The physical mechanisms of heat and mass transfer enhancement by ultrasound have been identified by people. Basically, the effect of 'cavitation' induced by ultrasound is the main reason for the enhancement of heat and mass transfer in a liquid environment, and the acoustic streaming and vibration are the main reasons for that in a gaseous environment. The adsorbent regeneration and food drying/dehydration are typical heat and mass transfer process, and the intensification of the two processes by ultrasound is of complete feasibility. This paper makes an overview on recent studies regarding applications of power ultrasound to adsorbent regeneration and food drying/dehydration. The concerned adsorbents include desiccant materials (typically like silica gel) for air dehumidification and other ones (typically active carbon and polymeric resin) for water treatment. The applications of ultrasound in the regeneration of these adsorbents have been proved to be energy saving. The concerned foods are mostly fruits and vegetables. Although the ultrasonic treatment may cause food degradation or nutrient loss, it can greatly reduce the food processing time and decrease drying temperature. From the literature, it can be seen that the ultrasonic conditions (i.e., acoustic frequency and power levels) are always focused on during the study of ultrasonic applications. The increasing number of relevant studies argues that ultrasound is a very promising technology applied to the adsorbent regeneration and food drying/dehydration. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Effect of controlled offset of focal position in cavitation-enhanced high-intensity focused ultrasound treatment

    NASA Astrophysics Data System (ADS)

    Goto, Kota; Takagi, Ryo; Miyashita, Takuya; Jimbo, Hayato; Yoshizawa, Shin; Umemura, Shin-ichiro

    2015-07-01

    High-intensity focused ultrasound (HIFU) is a noninvasive treatment for tumors such as cancer. In this method, ultrasound is generated outside the body and focused to the target tissue. Therefore, physical and mental stresses on the patient are minimal. A drawback of the HIFU treatment is a long treatment time for a large tumor due to the small therapeutic volume by a single exposure. Enhancing the heating effect of ultrasound by cavitation bubbles may solve this problem. However, this is rather difficult because cavitation clouds tend to be formed backward from the focal point while ultrasonic intensity for heating is centered at the focal point. In this study, the focal points of the trigger pulses to generate cavitation were offset forward from those of the heating ultrasound to match the cavitation clouds with the heating patterns. Results suggest that the controlled offset of focal points makes the thermal coagulation more predictable.

  6. Microbubbles in Ultrasound-Triggered Drug and Gene Delivery

    PubMed Central

    Hernot, Sophie; Klibanov, Alexander L.

    2008-01-01

    Ultrasound contrast agents, in the form of gas-filled microbubbles, are becoming popular in perfusion monitoring; they are employed as molecular imaging agents. Microbubbles are manufactured from biocompatible materials, they can be injected intravenously, and some are approved for clinical use. Microbubbles can be destroyed by ultrasound irradiation. This destruction phenomenon can be applied to targeted drug delivery and enhancement of drug action. The ultrasonic field can be focused at the target tissues and organs; thus, selectivity of the treatment can be improved, reducing undesirable side effects. Microbubbles enhance ultrasound energy deposition in the tissues and serve as cavitation nuclei, increasing intracellular drug delivery. DNA delivery and successful tissue transfection is observed in the areas of the body where ultrasound is applied after intravascular administration of microbubbles and plasmid DNA. Accelerated blood clot dissolution in the areas of insonation by cooperative action of thrombolytic agents and microbubbles is demonstrated in several clinical trials. PMID:18486268

  7. A Patient-Centered Approach to Guide Follow-Up and Adjunctive Testing and Treatment after First Rib Resection for Venous Thoracic Outlet Syndrome Is Safe and Effective

    PubMed Central

    Ryan, Colin P.; Mouawad, Nicolas J.; Vaccaro, Patrick S.; Go, Michael R.

    2018-01-01

    Controversies in the treatment of venous thoracic outlet syndrome (VTOS) have been discussed for decades, but still persist. Calls for more objective reporting standards have pushed practice towards comprehensive venous evaluations and interventions after first rib resection (FRR) for all patients. In our practice, we have relied on patient-centered, patient-reported outcomes to guide adjunctive treatment and measure success. Thus, we sought to investigate the use of thrombolysis versus anticoagulation alone, timing of FRR following thrombolysis, post-FRR venous intervention, and FRR for McCleery syndrome (MCS) and their impact on patient symptoms and return to function. All patients undergoing FRR for VTOS at our institution from 4 April 2000 through 31 December 2013 were reviewed. Demographics, symptoms, diagnostic and treatment details, and outcomes were collected. Per “Reporting Standards of the Society for Vascular Surgery for Thoracic Outlet Syndrome”, symptoms were described as swelling/discoloration/heaviness, collaterals, concomitant neurogenic symptoms, and functional impairment. Patient-reported response to treatment was defined as complete (no residual symptoms and return to function), partial (any residual symptoms present but no functional impairment), temporary (initial improvement but subsequent recurrence of any symptoms or functional impairment), or none (persistent symptoms or functional impairment). Sixty FRR were performed on 59 patients. 54.2% were female with a mean age of 34.3 years. Swelling/discoloration/heaviness was present in all but one patient, deep vein thrombosis in 80%, and visible collaterals in 41.7%. Four patients had pulmonary embolus while 65% had concomitant neurogenic symptoms. In addition, 74.6% of patients were anticoagulated and 44.1% also underwent thrombolysis prior to FRR. Complete or partial response occurred in 93.4%. Of the four patients with temporary or no response, further diagnostics revealed residual venous disease in two and occult alternative diagnoses in two. Use of thrombolysis was not related to FRR outcomes (p = 0.600). Performance of FRR less than or greater than six weeks after the initiation of anticoagulation or treatment with thrombolysis was not related to FRR outcomes (p = 1). Whether patients had DVT or MCS was not related to FRR outcomes (p = 1). No patient had recurrent DVT. From a patient-centered, patient-reported standpoint, VTOS is equally effectively treated with FRR regardless of preoperative thrombolysis or timing of surgery after thrombolysis. A conservative approach to venous interrogation and intervention after FRR is safe and effective for symptom control and return to function. Additionally, patients with MCS are effectively treated with FRR. PMID:29360741

  8. Villous adenoma of the common hepatic duct: the importance of contrast-enhanced ultrasound and endoscopic retrograde cholangiopancreatography for relevant diagnosis. A case report and review of the literature.

    PubMed

    Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu

    2015-12-01

    Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.

  9. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schellhammer, Frank, E-mail: frank.schellhammer@med.uni-duesseldorf.d; Esch, Jan Schulte am; Hammerschlag, Sascha

    2008-07-15

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  10. Clinical-Radiological Parameters Improve the Prediction of the Thrombolysis Time Window by Both MRI Signal Intensities and DWI-FLAIR Mismatch.

    PubMed

    Madai, Vince Istvan; Wood, Carla N; Galinovic, Ivana; Grittner, Ulrike; Piper, Sophie K; Revankar, Gajanan S; Martin, Steve Z; Zaro-Weber, Olivier; Moeller-Hartmann, Walter; von Samson-Himmelstjerna, Federico C; Heiss, Wolf-Dieter; Ebinger, Martin; Fiebach, Jochen B; Sobesky, Jan

    2016-01-01

    With regard to acute stroke, patients with unknown time from stroke onset are not eligible for thrombolysis. Quantitative diffusion weighted imaging (DWI) and fluid attenuated inversion recovery (FLAIR) MRI relative signal intensity (rSI) biomarkers have been introduced to predict eligibility for thrombolysis, but have shown heterogeneous results in the past. In the present work, we investigated whether the inclusion of easily obtainable clinical-radiological parameters would improve the prediction of the thrombolysis time window by rSIs and compared their performance to the visual DWI-FLAIR mismatch. In a retrospective study, patients from 2 centers with proven stroke with onset <12 h were included. The DWI lesion was segmented and overlaid on ADC and FLAIR images. rSI mean and SD, were calculated as follows: (mean ROI value/mean value of the unaffected hemisphere). Additionally, the visual DWI-FLAIR mismatch was evaluated. Prediction of the thrombolysis time window was evaluated by the area-under-the-curve (AUC) derived from receiver operating characteristic (ROC) curve analysis. Factors such as the association of age, National Institutes of Health Stroke Scale, MRI field strength, lesion size, vessel occlusion and Wahlund-Score with rSI were investigated and the models were adjusted and stratified accordingly. In 82 patients, the unadjusted rSI measures DWI-mean and -SD showed the highest AUCs (AUC 0.86-0.87). Adjustment for clinical-radiological covariates significantly improved the performance of FLAIR-mean (0.91) and DWI-SD (0.91). The best prediction results based on the AUC were found for the final stratified and adjusted models of DWI-SD (0.94) and FLAIR-mean (0.96) and a multivariable DWI-FLAIR model (0.95). The adjusted visual DWI-FLAIR mismatch did not perform in a significantly worse manner (0.89). ADC-rSIs showed fair performance in all models. Quantitative DWI and FLAIR MRI biomarkers as well as the visual DWI-FLAIR mismatch provide excellent prediction of eligibility for thrombolysis in acute stroke, when easily obtainable clinical-radiological parameters are included in the prediction models. © 2016 S. Karger AG, Basel.

  11. Value of contrast-enhanced ultrasound in the differential diagnosis of gallbladder lesion

    PubMed Central

    Zhang, Hui-Ping; Bai, Min; Gu, Ji-Ying; He, Ying-Qian; Qiao, Xiao-Hui; Du, Lian-Fang

    2018-01-01

    AIM To describe contrast-enhanced ultrasound (CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study included 105 gallbladder lesions. Before surgical resection and pathological examination, conventional ultrasound and CEUS were performed to examine for lesions. Then, all the lesions were diagnosed as (1) benign, (2) probably benign, (3) probably malignant or (4) malignant using both conventional ultrasound and CEUS. The CEUS features of these gallbladder lesions were analyzed and diagnostic efficiency between conventional ultrasound and CEUS was compared. RESULTS There were total 17 cases of gallbladder cancer and 88 cases of benign lesion. Some gallbladder lesions had typical characteristics on CEUS (e.g., gallbladder adenomyomatosis had typical characteristics of small nonenhanced areas on CEUS). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 94.1%, 95.5%, 80.0%, 98.8% and 95.2%, respectively. These were significantly higher than conventional ultrasound (82.4%, 89.8%, 60.9%, 96.3% and 88.6%, respectively). CEUS had an accuracy of 100% for gallbladder sludge and CEUS helped in differential diagnosis among gallbladder polyps, gallbladder adenoma and gallbladder cancer. CONCLUSION CEUS may provide more useful information and improve the diagnosis efficiency for the diagnosis of gallbladder lesions than conventional ultrasound. PMID:29456413

  12. Enzymolysis kinetics and structural characteristics of rice protein with energy-gathered ultrasound and ultrasound assisted alkali pretreatments.

    PubMed

    Li, Suyun; Yang, Xue; Zhang, Yanyan; Ma, Haile; Qu, Wenjuan; Ye, Xiaofei; Muatasim, Rahma; Oladejo, Ayobami Olayemi

    2016-07-01

    This research investigated the structural characteristics and enzymolysis kinetics of rice protein which was pretreated by energy-gathered ultrasound and ultrasound assisted alkali. The structural characteristics of rice protein before and after the pretreatment were performed with surface hydrophobicity and Fourier transform infrared (FTIR). There was an increase in the intensity of fluorescence spectrum and changes in functional groups after the pretreatment on rice protein compared with the control (without ultrasound and ultrasound assisted alkali processed), thus significantly enhancing efficiency of the enzymatic hydrolysis. A simplified kinetic equation for the enzymolysis model with the impeded reaction of enzyme was deduced to successfully describe the enzymatic hydrolysis of rice protein by different pretreatments. The initial observed rate constants (Kin,0) as well as ineffective coefficients (kimp) were proposed and obtained based on the experimental observation. The results showed that the parameter of kin,0 increased after ultrasound and ultrasound assisted alkali pretreatments, which proved the effects of the pretreatments on the substrate enhancing the enzymolysis process and had relation to the structure changes of the pretreatments on the substrate. Furthermore, the applicability of the simplified model was demonstrated by the enzymatic hydrolysis process for other materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Multiparametric ultrasound in the detection of prostate cancer: a systematic review.

    PubMed

    Postema, Arnoud; Mischi, Massimo; de la Rosette, Jean; Wijkstra, Hessel

    2015-11-01

    To investigate the advances and clinical results of the different ultrasound modalities and the progress in combining them into multiparametric UltraSound (mpUS). A systematic literature search on mpUS and the different ultrasound modalities included: greyscale ultrasound, computerized transrectal ultrasound, Doppler and power Doppler techniques, dynamic contrast-enhanced ultrasound and (shear wave) elastography. Limited research available on combining ultrasound modalities has presented improvement in diagnostic performance. The data of two studies suggest that even adding a lower performing ultrasound modality to a better performing modality using crude methods can already improve the sensitivity by 13-51 %. The different modalities detect different tumours. No study has tried to combine ultrasound modalities employing a system similar to the PIRADS system used for mpMRI or more advanced classifying algorithms. Available evidence confirms that combining different ultrasound modalities significantly improves diagnostic performance.

  14. Acoustic fingerprints of dye-labeled protein submicrosphere photoacoustic contrast agents

    NASA Astrophysics Data System (ADS)

    McDonald, Michael A.; Jankovic, Ladislav; Shahzad, Khalid; Burcher, Michael; Li, King C. P.

    2009-05-01

    Dye-labeled protein microspheres, submicron in size and capable of producing thermoelastically generated ultrasound in response to laser stimulation, are presented as contrast agents for photoacoustic imaging. Incident laser energy absorbed by fluorescein isothiocyanate (FITC)-labeled elastin submicrospheres results in thermoelastically generated sound production. Plotted A-line graphs reveal a distinctive morphology and a greater than two orders of magnitude increase in signal amplitude subsequent to converting FITC elastin into submicrospheres (despite a four orders of magnitude decrease in concentration). Evidence of nonlinearity and enhancement of ultrasound backscatter indicate a potential use in contrast-enhanced harmonic imaging. Photoacoustic and ultrasound imaging of FITC-elastin submicrospheres in a water-filled phantom vessel shows enhanced contrast at low concentration and clear delineation of the phantom vessel wall.

  15. Coagulation Testing in Acute Ischemic Stroke Patients Taking Non-Vitamin K Antagonist Oral Anticoagulants.

    PubMed

    Purrucker, Jan C; Haas, Kirsten; Rizos, Timolaos; Khan, Shujah; Poli, Sven; Kraft, Peter; Kleinschnitz, Christoph; Dziewas, Rainer; Binder, Andreas; Palm, Frederick; Jander, Sebastian; Soda, Hassan; Heuschmann, Peter U; Veltkamp, Roland

    2017-01-01

    In patients who present with acute ischemic stroke while on treatment with non-vitamin K antagonist oral anticoagulants (NOACs), coagulation testing is necessary to confirm the eligibility for thrombolytic therapy. We evaluated the current use of coagulation testing in routine clinical practice in patients who were on NOAC treatment at the time of acute ischemic stroke. Prospective multicenter observational RASUNOA registry (Registry of Acute Stroke Under New Oral Anticoagulants; February 2012-2015). Results of locally performed nonspecific (international normalized ratio, activated partial thromboplastin time, and thrombin time) and specific (antifactor Xa tests, hemoclot assay) coagulation tests were documented. The implications of test results for thrombolysis decision-making were explored. In the 290 patients enrolled, nonspecific coagulation tests were performed in ≥95% and specific coagulation tests in 26.9% of patients. Normal values of activated partial thromboplastin time and international normalized ratio did not reliably rule out peak drug levels at the time of the diagnostic tests (false-negative rates 11%-44% [95% confidence interval 1%-69%]). Twelve percent of patients apparently failed to take the prescribed NOAC prior to the acute event. Only 5.7% (9/159) of patients in the 4.5-hour time window received thrombolysis, and NOAC treatment was documented as main reason for not administering thrombolysis in 52.7% (79/150) of patients. NOAC treatment currently poses a significant barrier to thrombolysis in ischemic stroke. Because nonspecific coagulation test results within normal range have a high false-negative rate for detection of relevant drug concentrations, rapid drug-specific tests for thrombolysis decision-making should be established. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01850797. © 2016 American Heart Association, Inc.

  16. Diabetes mellitus, admission glucose, and outcomes after stroke thrombolysis: a registry and systematic review.

    PubMed

    Desilles, Jean-Philippe; Meseguer, Elena; Labreuche, Julien; Lapergue, Bertrand; Sirimarco, Gaia; Gonzalez-Valcarcel, Jaime; Lavallée, Philippa; Cabrejo, Lucie; Guidoux, Celine; Klein, Isabelle; Amarenco, Pierre; Mazighi, Mikael

    2013-07-01

    The potential detrimental effect of diabetes mellitus and admission glucose level (AGL) on outcomes after stroke thrombolysis is unclear. We evaluated outcomes of patients treated by intravenous and/or intra-arterial therapy, according to diabetes mellitus and AGL. We analyzed data from a patient registry (n=704) and conducted a systematic review of previous observational studies. The primary study outcome was the percentage of patients who achieved a favorable outcome (modified Rankin score ≤2 at 3 months). We identified 54 previous reports that evaluated the effect of diabetes mellitus or AGL on outcomes after thrombolysis. In an unadjusted meta-analysis that included our registry data and previous available observational data, diabetes mellitus was associated with less favorable outcome (odds ratio [OR], 0.76; 95% confidence interval [CI], 0.73-0.79) and more symptomatic intracranial hemorrhage (OR, 1.38; 95% CI, 1.21-1.56). However, in multivariable analysis, diabetes mellitus remained associated with less favorable outcome (OR, 0.77; 95% CI, 0.69-0.87) but not with symptomatic intracranial hemorrhage (OR, 1.11; 95% CI, 0.83-1.48). In unadjusted and in adjusted meta-analysis, higher AGL was associated with less favorable outcome and more symptomatic intracranial hemorrhage; the adjusted OR (95% CI) per 1 mmol/L increase in AGL was 0.92 (0.90-0.94) for favorable outcome, and 1.09 (1.04-1.14) for symptomatic intracranial hemorrhage. These results confirm that AGL and history of diabetes mellitus are associated with poor clinical outcome after thrombolysis. AGL may be a surrogate marker of brain infarction severity rather than a causal factor. However, randomized controlled evidences are needed to address the significance of a tight glucose control during thrombolysis on clinical outcome.

  17. Invasive strategy for treatment of myocardial infarction.

    PubMed

    Höfling, B; von Pölnitz, A

    1990-01-01

    The classical approach to the treatment of acute myocardial infarction (MI) has been one of stabilization and complication management. In an effort to optimize treatment, the initiation of the cardiac care unit and the use of antiarrhythmic therapy have succeeded in lowering the mortality rate substantially. More modern concepts are aimed at limiting infarct size and preserving myocardial function. These aims can be achieved medically using intravenous (i.v.) thrombolysis or invasively either with intracoronary (i.c.) thrombolysis, percutaneous transluminal coronary angioplasty (PTCA), or bypass surgery. Although i.c. thrombolysis is more effective than the i.v. route, the necessity for acute coronary catheterization makes it incompatible and difficult for routine use, and thus is usually reserved for cases in which i.v. lysis has failed. Intravenous thrombolysis is becoming the standard approach to MI, and the remaining questions are those of which drug and dosage are optimal and how to approach the patient after thrombolysis. In this regard, we favor a symptom-guided approach, as shown by the TIMI-IIA and European cooperative studies. In patients with ongoing ischemia postlysis, heart catheterization is indicated and a decision regarding PTCA or surgery is then made, depending on anatomy. In patients remaining stable after acute lysis, a predischarge stress may help in selecting patients requiring catheterization. As an alternative invasive approach to acute MI, PTCA may be the quickest and most effective method to recanalize a vessel, but, again, logistical problems make it incompatible in the acute setting. The same is true for bypass surgery, and although extensive improvements have been made in intraoperative myocardial preservation so that a 2% mortality is achievable, it is reserved for patients with extensive ischemia and anatomy unsuitable for PTCA (extensive multivessel or left main disease).

  18. Clinical update on thrombolytic use in pulmonary embolism: A focus on intermediate-risk patients.

    PubMed

    Eberle, Hannah; Lyn, Raquel; Knight, Tamara; Hodge, Emily; Daley, Mitchell

    2018-06-12

    Current literature on clinical controversies surrounding the use of thrombolytic agents in patients with intermediate-risk pulmonary embolism (PE) is reviewed. PE is a major cause of morbidity and mortality. When used in conjunction with anticoagulation, thrombolysis has been shown to reduce hemodynamic decompensation in select patients, but thrombolytic therapy is associated with high risks of bleeding and intracranial hemorrhage and its role in treating patients with intermediate-risk PE remains controversial. In the PEITHO study, the largest trial to date involving only patients with intermediate-risk PE ( n = 1,006), patients receiving the thrombolytic agent tenecteplase were significantly ( p = 0.02) less likely than those receiving unfractionated heparin to develop the primary outcome, a composite of death from any cause and hemodynamic decompensation or collapse within 7 days. However, a meta-analysis of data from clinical trials of systemic thrombolytic therapy in intermediate-risk PE generally showed a lack of benefit in terms of all-cause mortality and long-term complications. Novel strategies for treatment of intermediate-risk PE, including low-dose thrombolysis and catheter-directed thrombolysis, are being investigated in an attempt to identify strategies that provide therapeutic outcomes equivalent to those provided by traditional thrombolytic modalities but with a decreased risk of bleeding. The use of thrombolysis in the treatment of intermediate-risk PE is complicated by high rates of bleeding and should be limited to patients who clinically deteriorate rather than given as a standard-of-care treatment in this population. Data for low-dose thrombolysis remain limited. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  19. Fibrin sheaths in central venous port catheters: treatment with low-dose, single injection of urokinase on an outpatient basis.

    PubMed

    Chang, De-Hua; Mammadov, Kamal; Hickethier, Tilman; Borggrefe, Jan; Hellmich, Martin; Maintz, David; Kabbasch, Christoph

    2017-01-01

    Evaluation of the efficacy of single-shot, low-dose urokinase administration for the treatment of port catheter-associated fibrin sheaths. Forty-six patients were retrospectively evaluated for 54 episodes of port catheter dysfunction. The presence of a fibrin sheath was detected by angiographic contrast examinations. On an outpatient basis, patients subsequently received thrombolysis consisting of a single injection of urokinase (15.000 IU in 1.5 mL normal saline) through the port system. A second attempt was made in cases of treatment failure. Patients were followed up for technical success, complications and long-term outcome. Port dysfunction occurred at a median of 117 days after implantation (range: 7-825 days). The technical success after first port dysfunction by thrombolysis was 87% (40/46); thereof, initial thrombolysis was effective in 78% (36/46). Nine patients (20%) received a second dose of urokinase after previous treatment failure. Follow-up was available for 26 of 40 patients after successful thrombolysis. In 8 of these, rethrombosis occurred after a median of 98 days (range: 21-354 days), whereby rethrombolysis was effective in 5 of 7 (63%) patients. The overall success of all thrombolyses performed was 70% (45/64). No procedure-related technical or clinical complications occurred. After first favorable thrombolysis, a Kaplan-Meier analysis yielded a 30-, 90- and 180-day probability of patency of 96%, 87% and 81%. Thrombolytic therapy on an outpatient basis appears to be a safe and efficient. Three-month patency rates are comparable to more invasive treatment options, including catheter exchange over a guide wire and percutaneous fibrin sheath stripping.

  20. Fibrin sheaths in central venous port catheters: treatment with low-dose, single injection of urokinase on an outpatient basis

    PubMed Central

    Chang, De-Hua; Mammadov, Kamal; Hickethier, Tilman; Borggrefe, Jan; Hellmich, Martin; Maintz, David; Kabbasch, Christoph

    2017-01-01

    Purpose Evaluation of the efficacy of single-shot, low-dose urokinase administration for the treatment of port catheter-associated fibrin sheaths. Methods Forty-six patients were retrospectively evaluated for 54 episodes of port catheter dysfunction. The presence of a fibrin sheath was detected by angiographic contrast examinations. On an outpatient basis, patients subsequently received thrombolysis consisting of a single injection of urokinase (15.000 IU in 1.5 mL normal saline) through the port system. A second attempt was made in cases of treatment failure. Patients were followed up for technical success, complications and long-term outcome. Results Port dysfunction occurred at a median of 117 days after implantation (range: 7–825 days). The technical success after first port dysfunction by thrombolysis was 87% (40/46); thereof, initial thrombolysis was effective in 78% (36/46). Nine patients (20%) received a second dose of urokinase after previous treatment failure. Follow-up was available for 26 of 40 patients after successful thrombolysis. In 8 of these, rethrombosis occurred after a median of 98 days (range: 21–354 days), whereby rethrombolysis was effective in 5 of 7 (63%) patients. The overall success of all thrombolyses performed was 70% (45/64). No procedure-related technical or clinical complications occurred. After first favorable thrombolysis, a Kaplan–Meier analysis yielded a 30-, 90- and 180-day probability of patency of 96%, 87% and 81%. Conclusion Thrombolytic therapy on an outpatient basis appears to be a safe and efficient. Three-month patency rates are comparable to more invasive treatment options, including catheter exchange over a guide wire and percutaneous fibrin sheath stripping. PMID:28182117

  1. Reperfusion of occluded branch retinal arteries by transluminal Nd:YAG laser embolysis combined with intravenous thrombolysis of urokinase

    PubMed Central

    Chai, Fang; Du, Shanshuang; Zhao, Xiquan

    2017-01-01

    Purpose: To report successful treatment with transluminal Nd:YAG laser embolysis (TYE) combined with urokinase thrombolysis for reperfusion of occluded branch retinal arteries with visible emboli. Methods: A total of 34 eyes from 34 patients with acute, severe vision loss secondary to a branch retinal artery occlusion with visible emboli and retinal whitening were examined. Each patient was administered TYE therapy, which focused on the embolus, using an ocular contact lens; a 0.3–0.9 mJ laser pulse was delivered directly and gradually according to the reaction. Fundus photographs and fundus fluorescein angiography (FFA) were obtained before and immediately after the laser treatment. All patients received urokinase thrombolysis therapy drops intravenously for 5 days at 10–20 u/d. The follow-up period ranged from 6 to 14 months after therapy. The morphological characteristics of FFA associated with obstruction recovery of arterial fluorescence filling and visual function were analyzed. Results: After TYE therapy, FFA examinations showed that the retinal artery and its branches exhibited completely restored blood flow without obstruction in 13 eyes, accounting for 38.2% of the cases. The blood flow was mostly recovered in 11 eyes (32.4% of patients). FFA examinations following the combined intravenous urokinase thrombolysis therapy showed that the retinal artery and its branches exhibited completely restored blood flow after obstruction in 16 eyes (47.1% of patients). The blood flow was mostly recovered in 15 eyes (44.1% of patients). Conclusion: TYE combined with urokinase thrombolysis is effective for reperfusion of occluded branch retinal arteries and improving visual recovery in patients with visible emboli. PMID:29162667

  2. Development of a decision analytic model to support decision making and risk communication about thrombolytic treatment.

    PubMed

    McMeekin, Peter; Flynn, Darren; Ford, Gary A; Rodgers, Helen; Gray, Jo; Thomson, Richard G

    2015-11-11

    Individualised prediction of outcomes can support clinical and shared decision making. This paper describes the building of such a model to predict outcomes with and without intravenous thrombolysis treatment following ischaemic stroke. A decision analytic model (DAM) was constructed to establish the likely balance of benefits and risks of treating acute ischaemic stroke with thrombolysis. Probability of independence, (modified Rankin score mRS ≤ 2), dependence (mRS 3 to 5) and death at three months post-stroke was based on a calibrated version of the Stroke-Thrombolytic Predictive Instrument using data from routinely treated stroke patients in the Safe Implementation of Treatments in Stroke (SITS-UK) registry. Predictions in untreated patients were validated using data from the Virtual International Stroke Trials Archive (VISTA). The probability of symptomatic intracerebral haemorrhage in treated patients was incorporated using a scoring model from Safe Implementation of Thrombolysis in Stroke-Monitoring Study (SITS-MOST) data. The model predicts probabilities of haemorrhage, death, independence and dependence at 3-months, with and without thrombolysis, as a function of 13 patient characteristics. Calibration (and inclusion of additional predictors) of the Stroke-Thrombolytic Predictive Instrument (S-TPI) addressed issues of under and over prediction. Validation with VISTA data confirmed that assumptions about treatment effect were just. The C-statistics for independence and death in treated patients in the DAM were 0.793 and 0.771 respectively, and 0.776 for independence in untreated patients from VISTA. We have produced a DAM that provides an estimation of the likely benefits and risks of thrombolysis for individual patients, which has subsequently been embedded in a computerised decision aid to support better decision-making and informed consent.

  3. Stroke thrombolysis: save a minute, save a day.

    PubMed

    Meretoja, Atte; Keshtkaran, Mahsa; Saver, Jeffrey L; Tatlisumak, Turgut; Parsons, Mark W; Kaste, Markku; Davis, Stephen M; Donnan, Geoffrey A; Churilov, Leonid

    2014-04-01

    Stroke thrombolysis is highly time-critical, but data on long-term effects of small reductions in treatment delays have not been available. Our objective was to quantify patient lifetime benefits gained from faster treatment. Observational prospective data of consecutive stroke patients treated with intravenous thrombolysis in Australian and Finnish centers (1998-2011; n=2258) provided distributions of age, sex, stroke severity, onset-to-treatment times, and 3-month modified Rankin Scale in daily clinical practice. Treatment effects derived from a pooled analysis of thrombolysis trials were used to model the shift in 3-month modified Rankin Scale distributions with reducing treatment delays, from which we derived the expected lifetime and level of long-term disability with faster treatment. Each minute of onset-to-treatment time saved granted on average 1.8 days of extra healthy life (95% prediction interval, 0.9-2.7). Benefit was observed in all groups: each minute provided 0.6 day in old severe (age, 80 years; National Institutes of Health Stroke Scale [NIHSS] score, 20) patients, 0.9 day in old mild (age, 80 years; NIHSS score, 4) patients, 2.7 days in young mild (age, 50 years; NIHSS score, 4) patients, and 3.5 days in young severe (age, 50 years; NIHSS score, 20) patients. Women gained slightly more than men over their longer lifetimes. In the whole cohort, each 15 minute decrease in treatment delay provided an average equivalent of 1 month of additional disability-free life. Realistically achievable small reductions in stroke thrombolysis delays would result in significant and robust average health benefits over patients' lifetimes. The awareness of concrete importance of speed could promote practice change.

  4. Insulin resistance is associated with a poor response to intravenous thrombolysis in acute ischemic stroke.

    PubMed

    Calleja, Ana I; García-Bermejo, Pablo; Cortijo, Elisa; Bustamante, Rosa; Rojo Martínez, Esther; González Sarmiento, Enrique; Fernández-Herranz, Rosa; Arenillas, Juan F

    2011-11-01

    Insulin resistance (IR) may not only increase stroke risk, but could also contribute to aggravate stroke prognosis. Mainly through a derangement in endogenous fibrinolysis, IR could affect the response to intravenous thrombolysis, currently the only therapy proved to be efficacious for acute ischemic stroke. We hypothesized that high IR is associated with more persistent arterial occlusions and poorer long-term outcome after stroke thrombolysis. We performed a prospective, observational, longitudinal study in consecutive acute ischemic stroke patients presenting with middle cerebral artery (MCA) occlusion who received intravenous thrombolysis. Patients with acute hyperglycemia (≥155 mg/dL) receiving insulin were excluded. IR was determined during admission by the homeostatic model assessment index (HOMA-IR). Poor long-term outcome, as defined by a day 90 modified Rankin scale score ≥ 3, was considered the primary outcome variable. Transcranial Duplex-assessed resistance to MCA recanalization and symptomatic hemorrhagic transformation were considered secondary end points. A total of 109 thrombolysed MCA ischemic stroke patients were included (43.1% women, mean age 71 years). The HOMA-IR was higher in the group of patients with poor outcome (P = 0.02). The probability of good outcome decreased gradually with increasing HOMA-IR tertiles (80.6%, 1st tertile; 71.4%, 2nd tertile; and 55.3%, upper tertile). A HOMA-IR in the upper tertile was independently associated with poor outcome when compared with the lower tertile (odds ratio [OR] 8.54 [95% CI 1.67-43.55]; P = 0.01) and was associated with more persistent MCA occlusions (OR 8.2 [1.23-54.44]; P = 0.029). High IR may be associated with more persistent arterial occlusions and worse long-term outcome after acute ischemic stroke thrombolysis.

  5. Insulin Resistance Is Associated With a Poor Response to Intravenous Thrombolysis in Acute Ischemic Stroke

    PubMed Central

    Calleja, Ana I.; García-Bermejo, Pablo; Cortijo, Elisa; Bustamante, Rosa; Rojo Martínez, Esther; González Sarmiento, Enrique; Fernández-Herranz, Rosa; Arenillas, Juan F.

    2011-01-01

    OBJECTIVE Insulin resistance (IR) may not only increase stroke risk, but could also contribute to aggravate stroke prognosis. Mainly through a derangement in endogenous fibrinolysis, IR could affect the response to intravenous thrombolysis, currently the only therapy proved to be efficacious for acute ischemic stroke. We hypothesized that high IR is associated with more persistent arterial occlusions and poorer long-term outcome after stroke thrombolysis. RESEARCH DESIGN AND METHODS We performed a prospective, observational, longitudinal study in consecutive acute ischemic stroke patients presenting with middle cerebral artery (MCA) occlusion who received intravenous thrombolysis. Patients with acute hyperglycemia (≥155 mg/dL) receiving insulin were excluded. IR was determined during admission by the homeostatic model assessment index (HOMA-IR). Poor long-term outcome, as defined by a day 90 modified Rankin scale score ≥3, was considered the primary outcome variable. Transcranial Duplex-assessed resistance to MCA recanalization and symptomatic hemorrhagic transformation were considered secondary end points. RESULTS A total of 109 thrombolysed MCA ischemic stroke patients were included (43.1% women, mean age 71 years). The HOMA-IR was higher in the group of patients with poor outcome (P = 0.02). The probability of good outcome decreased gradually with increasing HOMA-IR tertiles (80.6%, 1st tertile; 71.4%, 2nd tertile; and 55.3%, upper tertile). A HOMA-IR in the upper tertile was independently associated with poor outcome when compared with the lower tertile (odds ratio [OR] 8.54 [95% CI 1.67–43.55]; P = 0.01) and was associated with more persistent MCA occlusions (OR 8.2 [1.23–54.44]; P = 0.029). CONCLUSIONS High IR may be associated with more persistent arterial occlusions and worse long-term outcome after acute ischemic stroke thrombolysis. PMID:21911778

  6. Optical tomography of fluorophores in dense scattering media based on ultrasound-enhanced chemiluminescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kobayashi, Masaki, E-mail: masaki@tohtech.ac.jp; Kikuchi, Naoto; Sato, Akihiro

    This letter proposes and demonstrates ultrasound-combined optical imaging in dense scattering media. A peroxyoxalate chemiluminescence system that includes fluorophores to chemically excite the pigment is stimulated by ultrasound irradiation with power of less than 0.14 W/cm{sup 2}. Using focused ultrasound, the chemiluminescence is selectively spatially enhanced, which leads to imaging of the pigment when embedded in a light-scattering medium via scanning of the focal point. The ultrasonically enhanced intensity of the chemiluminescence depends on the base intensity of the chemiluminescence without the applied ultrasound irradiation, which thereby enables quantitative determination of the fluorophore concentration. The authors demonstrate the potential of thismore » method to resolve chemiluminescent targets in a dense scattering medium that is comparable to biological tissue. An image was acquired of a chemiluminescent target that included indocyanine green as the fluorophore embedded at a depth of 20 mm in an Intralipid-10% 200 ml/l solution scattering medium (the reduced scattering coefficient was estimated to be approximately 1.3 mm{sup −1}), indicating the potential for expansion of this technique for use in biological applications.« less

  7. Enhancing mung bean hydration using the ultrasound technology: description of mechanisms and impact on its germination and main components

    NASA Astrophysics Data System (ADS)

    Miano, Alberto Claudio; Pereira, Jessica Da Costa; Castanha, Nanci; Júnior, Manoel Divino Da Matta; Augusto, Pedro Esteves Duarte

    2016-12-01

    The ultrasound technology was successfully used to improve the mass transfer processes on food. However, the study of this technology on the grain hydration and on its main components properties was still not appropriately described. This work studied the application of the ultrasound technology on the hydration process of mung beans (Vigna radiata). This grain showed sigmoidal hydration behavior with a specific water entrance pathway. The ultrasound reduced ~25% of the hydration process time. In addition, this technology caused acceleration of the seed germination - and some hypothesis for this enhancement were proposed. Moreover, it was demonstrated that the ultrasound did not change both structure and pasting properties of the bean starch. Finally, the flour rheological properties proved that the ultrasound increased its apparent viscosity, and as the starch was not modified, this alteration was attributed to the proteins. All these results are very desirable for industry since the ultrasound technology improves the hydration process without altering the starch properties, accelerates the germination process (that is important for the malting and sprouting process) and increases the flour apparent viscosity, which is desirable to produce bean-based products that need higher consistency.

  8. Contrast-enhanced ultrasound in diagnosis of gallbladder adenoma.

    PubMed

    Yuan, Hai-Xia; Cao, Jia-Ying; Kong, Wen-Tao; Xia, Han-Sheng; Wang, Xi; Wang, Wen-Ping

    2015-04-01

    Gallbladder adenoma is a pre-cancerous neoplasm and needs surgical resection. It is difficult to differentiate adenoma from other gallbladder polyps using imaging examinations. The study aimed to illustrate characteristics of contrast-enhanced ultrasound (CEUS) and its diagnostic value in gallbladder adenoma. Thirty-seven patients with 39 gallbladder adenomatoid lesions (maximal diameter ≥10 mm and without metastasis) were enrolled in this study. Lesion appearances in conventional ultrasound and CEUS were documented. The imaging features were compared individually among gallbladder cholesterol polyp, gallbladder adenoma and malignant lesion. Adenoma lesions showed iso-echogenicity in ultrasound, and an eccentric enhancement pattern, "fast-in and synchronous-out" contrast enhancement pattern and homogeneous at peak-time enhancement in CEUS. The homogenicity at peak-time enhancement showed the highest diagnostic ability in differentiating gallbladder adenoma from cholesterol polyps. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy and Youden index were 100%, 90.9%, 92.9%, 100%, 95.8% and 0.91, respectively. The characteristic of continuous gallbladder wall shown by CEUS had the highest diagnostic ability in differentiating adenoma from malignant lesion (100%, 86.7%, 86.7%, 100%, 92.9% and 0.87, respectively). The characteristic of the eccentric enhancement pattern had the highest diagnostic ability in differentiating adenoma from cholesterol polyp and malignant lesion, with corresponding indices of 69.2%, 88.5%, 75.0%, 85.2%, 82.1% and 0.58, respectively. CEUS is valuable in differentiating gallbladder adenoma from other gallbladder polyps (≥10 mm in diameter). Homogeneous echogenicity on peak-time enhancement, a continuous gallbladder wall, and the eccentric enhancement pattern are important indicators of gallbladder adenoma on CEUS.

  9. Ultrasonically targeted delivery into endothelial and smooth muscle cells in ex vivo arteries

    PubMed Central

    Hallow, Daniel M.; Mahajan, Anuj D.; Prausnitz, Mark R.

    2007-01-01

    This study tested the hypothesis that ultrasound can target intracellular uptake of drugs into vascular endothelial cells (ECs) at low to intermediate energy and into smooth muscle cells (SMCs) at high energy. Ultrasound-enhanced delivery has been shown to enhance and target intracellular drug and gene delivery in the vasculature to treat cardiovascular disease, but quantitative studies of the delivery process are lacking. Viable ex vivo porcine carotid arteries were placed in a solution containing a model drug, TO-PRO®-1, and Optison® microbubbles. Arteries were exposed to ultrasound at 1.1 MHz and acoustic energies of 5.0, 66, or 630 J/cm2. Using confocal microscopy and fluorescent labeling of cells, the artery endothelium and media were imaged to determine the localization and to quantify intracellular uptake and cell death. At low to intermediate ultrasound energy, ultrasound was shown to target intracellular delivery into viable cells that represented 9 – 24% of exposed ECs. These conditions also typically caused 7 – 25% EC death. At high energy, intracellular delivery was targeted to SMCs, which was associated with denuding or death of proximal ECs. This work represents the first known in-depth study to evaluate intracellular uptake into cells in tissue. We conclude that significant intracellular uptake of molecules can be targeted into ECs and SMCs by ultrasound-enhanced delivery suggesting possible applications for treatment of cardivascular diseases and dysfunctions. PMID:17291619

  10. Interleukin 16- (IL-16-) Targeted Ultrasound Imaging Agent Improves Detection of Ovarian Tumors in Laying Hens, a Preclinical Model of Spontaneous Ovarian Cancer.

    PubMed

    Barua, Animesh; Yellapa, Aparna; Bahr, Janice M; Adur, Malavika K; Utterback, Chet W; Bitterman, Pincas; Basu, Sanjib; Sharma, Sameer; Abramowicz, Jacques S

    2015-01-01

    Limited resolution of transvaginal ultrasound (TVUS) scanning is a significant barrier to early detection of ovarian cancer (OVCA). Contrast agents have been suggested to improve the resolution of TVUS scanning. Emerging evidence suggests that expression of interleukin 16 (IL-16) by the tumor epithelium and microvessels increases in association with OVCA development and offers a potential target for early OVCA detection. The goal of this study was to examine the feasibility of IL-16-targeted contrast agents in enhancing the intensity of ultrasound imaging from ovarian tumors in hens, a model of spontaneous OVCA. Contrast agents were developed by conjugating biotinylated anti-IL-16 antibodies with streptavidin coated microbubbles. Enhancement of ultrasound signal intensity was determined before and after injection of contrast agents. Following scanning, ovarian tissues were processed for the detection of IL-16 expressing cells and microvessels. Compared with precontrast, contrast imaging enhanced ultrasound signal intensity significantly in OVCA hens at early (P < 0.05) and late stages (P < 0.001). Higher intensities of ultrasound signals in OVCA hens were associated with increased frequencies of IL-16 expressing cells and microvessels. These results suggest that IL-16-targeted contrast agents improve the visualization of ovarian tumors. The laying hen may be a suitable model to test new imaging agents and develop targeted anti-OVCA therapeutics.

  11. Dynamic Magnetic Resonance Angiography Provides Collateral Circulation and Hemodynamic Information in Acute Ischemic Stroke.

    PubMed

    Hernández-Pérez, María; Puig, Josep; Blasco, Gerard; Pérez de la Ossa, Natalia; Dorado, Laura; Dávalos, Antoni; Munuera, Josep

    2016-02-01

    Contrary to usual static vascular imaging techniques, contrast-enhanced dynamic magnetic resonance angiography (dMRA) enables dynamic study of cerebral vessels. We evaluated dMRA ability to assess arterial occlusion, cerebral hemodynamics, and collateral circulation in acute ischemic stroke. Twenty-five acute ischemic stroke patients with proximal anterior circulation occlusion underwent dMRA on a 3T scanner within 12 hours of symptoms onset. Diffusion weighted imaging, Tmax6 s lesion volumes and hypoperfusion intensity ratio as volume of Tmax>6 s/volume of Tmax>10 s were measured. Site and grade of occlusion (Thrombolysis in Myocardial Infarction criteria) were evaluated on time-of-flight MRA and dMRA. Leptomeningeal collaterality (American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology [ASITN/SIR] Scale) and asymmetries in venous clearance were assessed exclusively on dMRA. Collateral filling was dichotomized into incomplete (ASITN/SIR 0-2) or complete (ASITN/SIR 3-4). On dMRA, site of occlusion was M1 in 21 patients, tandem internal carotid artery/M1 in 2 and tandem internal carotid artery/terminal internal carotid artery in 2 patients. Three tandem occlusions were not detected on time-of-flight-MRA. All patients had Thrombolysis in Myocardial Infarction 0 to 1 on time-of-flight-MRA, but three of them had Thrombolysis in Myocardial Infarction 2 on dMRA. Complete collateral filling (n=12, 48%) was associated with smaller diffusion weighted imaging lesion volume (P=0.039), smaller hypoperfused volume (P=0.018), and lower hypoperfusion intensity ratio (P=0.006). Patients with symmetrical clearance of transverse sinuses (52%) were more likely to have complete collateral filling (P=0.015). As a fast, direct, feasible, noninvasive, and reliable method to assess site of occlusion, collateral circulation and hemodynamic alterations, dMRA provides profound insights in acute stroke. © 2015 American Heart Association, Inc.

  12. Lipid-shelled vehicles: engineering for ultrasound molecular imaging and drug delivery.

    PubMed

    Ferrara, Katherine W; Borden, Mark A; Zhang, Hua

    2009-07-21

    Ultrasound pressure waves can map the location of lipid-stabilized gas micro-bubbles after their intravenous administration in the body, facilitating an estimate of vascular density and microvascular flow rate. Microbubbles are currently approved by the Food and Drug Administration as ultrasound contrast agents for visualizing opacification of the left ventricle in echocardiography. However, the interaction of ultrasound waves with intravenously-injected lipid-shelled particles, including both liposomes and microbubbles, is a far richer field. Particles can be designed for molecular imaging and loaded with drugs or genes; the mechanical and thermal properties of ultrasound can then effect localized drug release. In this Account, we provide an overview of the engineering of lipid-shelled microbubbles (typical diameter 1000-10 000 nm) and liposomes (typical diameter 65-120 nm) for ultrasound-based applications in molecular imaging and drug delivery. The chemistries of the shell and core can be optimized to enhance stability, circulation persistence, drug loading and release, targeting to and fusion with the cell membrane, and therapeutic biological effects. To assess the biodistribution and pharmacokinetics of these particles, we incorporated positron emission tomography (PET) radioisotopes on the shell. The radionuclide (18)F (half-life approximately 2 h) was covalently coupled to a dipalmitoyl lipid, followed by integration of the labeled lipid into the shell, facilitating short-term analysis of particle pharmacokinetics and metabolism of the lipid molecule. Alternately, labeling a formed particle with (64)Cu (half-life 12.7 h), after prior covalent incorporation of a copper-chelating moiety onto the lipid shell, permits pharmacokinetic study of particles over several days. Stability and persistence in circulation of both liposomes and microbubbles are enhanced by long acyl chains and a poly(ethylene glycol) coating. Vascular targeting has been demonstrated with both nano- and microdiameter particles. Targeting affinity of the microbubble can be modulated by burying the ligand within a polymer brush layer; the application of ultrasound then reveals the ligand, enabling specific targeting of only the insonified region. Microbubbles and liposomes require different strategies for both drug loading and release. Microbubble loading is inhibited by the gas core and enhanced by layer-by-layer construction or conjugation of drug-entrapped particles to the surface. Liposome loading is typically internal and is enhanced by drug-specific loading techniques. Drug release from a microbubble results from the oscillation of the gas core diameter produced by the sound wave, whereas that from a liposome is enhanced by heat produced from the local absorption of acoustic energy within the tissue microenvironment. Biological effects induced by ultrasound, such as changes in cell membrane and vascular permeability, can enhance drug delivery. In particular, as microbubbles oscillate near a vessel wall, shock waves or liquid jets enhance drug transport. Mild heating induced by ultrasound, either before or after injection of the drug, facilitates the transport of liposomes from blood vessels to the tissue interstitium, thus increasing drug accumulation in the target region. Lipid-shelled vehicles offer many opportunities for chemists and engineers; ultrasound-based applications beyond the few currently in common use will undoubtedly soon multiply as molecular construction techniques are further refined.

  13. ULTRASOUND PRETREATMENT OF ELEMENTAL IRON: KINETIC STUDIES OF DEHALOGENATION REACTION ENHANCEMENT AND SURFACE EFFECTS. (R828598C743)

    EPA Science Inventory

    This work presents data showing the kinetic improvement afforded by ultrasound pretreatment and illustrates the physical and chemical changes that take place at the iron surface. First-order rate constants improved as much as 78% with 2 h of ultrasound pretreatment. Scann...

  14. Blood-Brain Barrier Disruption Caused by Ultrasound Bursts Combined with Microbubbles Depends on Anesthesia

    NASA Astrophysics Data System (ADS)

    McDannold, Nathan; Zhang, Yongzhi; Vykhodtseva, Natalia

    2011-09-01

    Prior works on BBB disruption via inter-arterial infusions of osmotic agents have shown a strong dependence on anesthesia. Here, we investigated whether different anesthesia agents can affect ultrasound-induced BBB disruption. A piston transducer fired through a rubber aperture (frequency: 532 kHz, diameter: 4 cm, aperture diameter: 16 mm) was used to generate the ultrasound fields, and sonications combined with an ultrasound contrast agent were performed at 5 power levels. BBB disruption was quantified by measuring the MRI contrast enhancement in T1-weighted MRI, and erythrocyte extravasation characterized in light microscopy. For each exposure level tested, experiments performed with ketamine/xylazine resulted in significantly greater (P<0.05) enhancement than with isoflurane/oxygen. The onset of severe red blood cell extravasation occurred at lower power levels with ketamine/xylazine. These results suggest ultrasound-induced BBB disruption can depend on anesthesia agent, possibly due effects on the vasculature. These results suggest that care is needed in comparing experiments with different anesthesia agents and physiological factors need to be considered with ultrasound-induced BBB disruption.

  15. Focused Ultrasound-Induced Neurogenesis Requires an Increase in Blood-Brain Barrier Permeability.

    PubMed

    Mooney, Skyler J; Shah, Kairavi; Yeung, Sharon; Burgess, Alison; Aubert, Isabelle; Hynynen, Kullervo

    2016-01-01

    Transcranial focused ultrasound technology used to transiently open the blood-brain barrier, is capable of stimulating hippocampal neurogenesis; however, it is not yet known what aspects of the treatment are necessary for enhanced neurogenesis to occur. The present study set out to determine whether the opening of blood-brain barrier, the specific pressure amplitudes of focused ultrasound, and/or the intravenous administration of microbubbles (phospholipid microspheres) are necessary for the enhancement of neurogenesis. Specifically, mice were exposed to burst (10ms, 1Hz burst repetition frequency) focused ultrasound at the frequency of 1.68MHz and with 0.39, 0.78, 1.56 and 3.0MPa pressure amplitudes. These treatments were also conducted with or without microbubbles, at 0.39 + 0.78MPa or 1.56 + 3.0MPa, respectively. Only focused ultrasound at the ~0.78 MPa pressure amplitude with microbubbles promoted hippocampal neurogenesis and was associated with an increase in blood-brain barrier permeability. These results suggest that focused ultrasound -mediated neurogenesis is dependent upon the opening of the blood-brain barrier.

  16. Outcomes After Direct Thrombectomy or Combined Intravenous and Endovascular Treatment Are Not Different.

    PubMed

    Abilleira, Sònia; Ribera, Aida; Cardona, Pedro; Rubiera, Marta; López-Cancio, Elena; Amaro, Sergi; Rodríguez-Campello, Ana; Camps-Renom, Pol; Cánovas, David; de Miquel, Maria Angels; Tomasello, Alejandro; Remollo, Sebastian; López-Rueda, Antonio; Vivas, Elio; Perendreu, Joan; Gallofré, Miquel

    2017-02-01

    Whether intravenous thrombolysis adds a further benefit when given before endovascular thrombectomy (EVT) is unknown. Furthermore, intravenous thrombolysis delays time to groin puncture, mainly among drip and ship patients. Using region-wide registry data, we selected cases that received direct EVT or combined intravenous thrombolysis+EVT for anterior circulation strokes between January 2011 and October 2015. Treatment effect was estimated by stratification on a propensity score. The average odds ratios for the association of treatment with good outcome and death at 3 months and symptomatic bleedings at 24 hours were calculated with the Mantel-Haenszel test statistic. We included 599 direct EVT patients and 567 patients with combined treatment. Stratification through propensity score achieved balance of baseline characteristics across treatment groups. There was no association between treatment modality and good outcome (odds ratio, 0.97; 95% confidence interval, 0.74-1.27), death (odds ratio, 1.07; 95% confidence interval, 0.74-1.54), or symptomatic bleedings (odds ratio, 0.56; 95% confidence interval, 0.25-1.27). This observational study suggests that outcomes after direct EVT or combined intravenous thrombolysis+EVT are not different. If confirmed by a randomized controlled trial, it may have a significant impact on organization of stroke systems of care. © 2017 American Heart Association, Inc.

  17. Twelve-month experience of acute stroke thrombolysis in Christchurch, New Zealand: emergency department screening and acute stroke service treatment.

    PubMed

    Fink, John

    2005-05-06

    To determine the safety and efficiency of an acute stroke thrombolysis service in a New Zealand public hospital setting. A 12-month audit of patients referred to the Christchurch Hospital Stroke Thrombolysis Service (STS) between 1 April 2002 and 31 March 2003 was undertaken. Sixty-one patients were referred to the STS during the study period, of whom 16 were treated with tissue plasminogen activator (t-PA). For treated patients, the median time from stroke onset to hospital presentation was 60 minutes, 'door-to-CT' time was 60 minutes, and the 'door-to-needle' time was 99 minutes. Minor protocol violations were recorded in two patients, but did not influence outcome. No patient was treated after 3 hours of stroke onset. Intracerebral haemorrhage occurred in two patients: one patient was significantly improved compared with pre-treatment status; a minor temporary deterioration occurred in the other patient. Eight of 16 patients had improved by 4 or more points on the NIH Stroke Scale Score at 24 hours. Acute stroke thrombolysis can be delivered safely and in accordance with internationally accepted guidelines using the Christchurch Hospital STS model of emergency department screening and acute stroke service treatment. Further improvements in performance of the STS remain possible.

  18. Does the 'diffusion of innovations' model enrich understanding of research use? Case studies of the implementation of thrombolysis services for stroke.

    PubMed

    Boaz, Annette; Baeza, Juan; Fraser, Alec

    2016-10-01

    To test whether the model of 'diffusion of innovations' enriches understanding of the implementation of evidence-based thrombolysis services for stroke patients. Four case studies of the implementation of evidence on thrombolysis in stroke services in England and Sweden. Semistructured interviews with 95 staff including doctors, nurses and managers working in stroke units, emergency medicine, radiology, the ambulance service, community rehabilitation services and commissioners. The implementation of thrombolysis in acute stroke management benefited from a critical mass of the factors featured in the model including: the support of national and local opinion leaders; a strong evidence base and financial incentives. However, while the model provided a starting point as an organizational framework for mapping the critical factors influencing implementation, to understand properly the process of implementation and the importance of the different factors identified, more detailed analyses of context and, in particular, of the human and social dimensions of change was needed. While recognising the usefulness of the model of diffusion of innovations in mapping the processes by which diffusion occurs, the use of methods that lend themselves to in-depth analysis, such as ethnography and the application of relevant bodies of social theory, are needed. © The Author(s) 2016.

  19. Thrombo-embolectomy and thrombolytic therapy in acute lower limb ischaemia. A five year experience.

    PubMed

    Singh, S; Ackroyd, R; Lees, T; Morris-Jones, W; Gaines, P; Beard, J D

    1996-03-01

    Between 1988 and 1993, 82 patients with a median age (iq range) of 81 (73-87) years underwent thrombo-embolectomy (TE) and thrombolysis for acute lower limb ischaemia at the Royal Hallamshire Hospital, Sheffield. 28 patients (Group 1) underwent TE prior to the introduction of thrombolysis in 1991. TE with intraoperative thrombolysis (IT) as an adjunct was performed in 34 patients (Group 2) and 20 patients (Group 3) were treated using percutaneous thrombolysis (PT) in the first instance. 41 of these patients were in AF at presentation. Although 24 were on digoxin, only 4 were on warfarin. Group 3 patients were younger (p < 0.05; ANOVA) with a longer duration of ischaemia (p < 0.05; ANOVA) and had less limbs suffering a sensorimotor deficit (p = 0.007; chi 2) compared with Groups 1 and 2 which were similar in these respects. Overall mortality was 17%. Successful revascularisation was achieved in 18 (64%), 28 (82%) and 15 (75%) patients in Groups 1, 2 and 3 respectively. 14 of the 15 patients successfully treated initially by PT required further intervention in order to maintain revascularisation. Revascularisation failure was associated with the presence of a sensorimotor deficit but not associated with patient age or duration of ischaemia.

  20. Electrolytic echo enhancement: a novel method to make needles more reflective to ultrasound.

    PubMed

    Cockburn, John F; Khosh, Stefan K

    2014-04-01

    This study examines the effect of augmenting the ultrasound reflectivity of needles using a novel electrolytic echo enhancement method. Needles were connected by a lead to the negative terminal of a 4.5 V direct current source. A grounding pad, connected to the positive terminal, was positioned on the undersurface of an ex vivo ox liver phantom. During needle insertion into the liver, electrolysis was induced creating a layer of gas on the needle electrode. Analysis of images showed a significant increase in needle brightness using electrolytic echo enhancement. Brightness was found to increase by a factor of ×3.6 compared with controls (P < 0.001). Electrolytic echo enhancement has the potential to make ultrasound-guided procedures safer and quicker for patients and increase the confidence of operators in their ability to see the whole needle including its tip. © 2014 The Royal Australian and New Zealand College of Radiologists.

  1. The role of contrast-enhanced ultrasound in imaging carotid arterial diseases.

    PubMed

    Clevert, Dirk A; Paprottka, Philipp; Sommer, Wieland H; Helck, Andreas; Reiser, Maximilian F; Zengel, Pamela

    2013-06-01

    The standard of care for the initial diagnosis of carotid artery bifurcation diseases is carotid duplex ultrasound. Carotid abnormalities or difficult examinations may represent a diagnostic challenge in patients with clinical symptoms as well as in the follow-up after carotid endarterectomy, carotid artery stenting or other interventions. A promising new method in the diagnosis and follow-up of pathologic carotid diseases is contrast-enhanced ultrasound (CEUS). In comparison with magnetic resonance imaging or computed tomography, the contrast agents used for CEUS remain within the vascular space and hence can be used to study vascular disease and could provide additional information on carotid arterial diseases. This review describes the current carotid duplex ultrasound examination and compares the pathologic findings with CEUS. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Ultrasound has synergistic effects in vitro with tirofiban and heparin for thrombus dissolution.

    PubMed

    Birnbaum, Y; Atar, S; Luo, H; Nagai, T; Siegel, R J

    1999-12-15

    Previous studies have shown synergism between ultrasound and thrombolytic agents or microbubbles on blood clot dissolution. It has not been investigated whether heparin or glycoprotein IIb/IIIa blockers enhance clot lysis by ultrasound. We compared the blood clot dissolution effect of saline, heparin, tissue plasminogen activator (tPA), tirofiban, and an echocardiographic contrast media (Optison) without and with ultrasound application. Human blood clots from four donors, 2 to 4 hours old, were cut into 200- to 400-mg sections, weighed, and immersed for 2 minutes in 1 L of normal saline 0.9% solution containing either heparin 1000 U, tirofiban 150 microg, tPA 20 mg, Optison 0.5 mL, or normal saline alone. Clots were randomized to 2 minutes ultrasound application or immersion alone without ultrasound. Ultrasound was applied with a 19.5 KHz catheter. After treatment, the clots were weighed, and the absolute and percent difference in weight was calculated. Immersion in heparin, tirofiban, and tPA without ultrasound did not augment clot disruption relative to normal saline alone. Immersion in Optison (p = 0.07) tended to result in less lysis than saline alone. Ultrasound enhanced clot dissolution compared to immersion alone with: saline (48.1+/-15.3% vs. 26.0+/-13.8%, p<0.0000002); heparin (60.8+/-17.5% vs. 30.8+/-15.1%, p = 0.000001); tirofiban (61.8+/-13.6% vs. 30.1+/-12.2%, p<0.0000001); tPA (53.1+/-15.3% vs. 30.2+/-11.5%, p<0.000002); and Optison (47.8+/-16.0% vs. 18.4+/-11.5%, p<0.0000001). The combination of tirofiban with ultrasound, as well as heparin with ultrasound, was associated with a significant augmentation of clot dissolution compared with the saline plus ultrasound group (p = 0.002, 0.013, respectively). Ultrasound with tPA or with Optison had no significant augmentation of clot dissolution over the ultrasound + saline effect. This in vitro study of catheter-delivered high-intensity low-frequency ultrasound demonstrates that: (1) tirofiban and heparin, as well as perfluorocarbon microbubbles, augment clot dissolution by ultrasound; (2) augmentation of clot dissolution is evident even after only brief exposure of ultrasound and the drug studied.

  3. Quantitative Contrast-Enhanced Ultrasound Parameters in Crohn Disease: Their Role in Disease Activity Determination With Ultrasound.

    PubMed

    Medellin-Kowalewski, Alexandra; Wilkens, Rune; Wilson, Alexandra; Ruan, Ji; Wilson, Stephanie R

    2016-01-01

    The primary objective of our study was to examine the association between contrast-enhanced ultrasound (CEUS) parameters and established gray-scale ultrasound with color Doppler imaging (CDI) for the determination of disease activity in patients with Crohn disease. Our secondary objective was to develop quantitative time-signal intensity curve thresholds for disease activity. One hundred twenty-seven patients with Crohn disease underwent ultrasound with CDI and CEUS. Reviewers graded wall thickness, inflammatory fat, and mural blood flow as showing remission or inflammation (mild, moderate, or severe). If both gray-scale ultrasound and CDI predicted equal levels of disease activity, the studies were considered concordant. If ultrasound images suggested active disease not supported by CDI findings, the ultrasound results for disease activity were indeterminate. Time-signal intensity curves from CEUS were acquired with calculation of peak enhancement (PE), and AUCs. Interobserver variation and associations between PE and ultrasound parameters were examined. Multiclass ROC analysis was used to develop CEUS thresholds for activity. Ninety-six (76%) studies were concordant, 19 of which showed severe disease, and 31 (24%) studies were indeterminate. Kappa analyses revealed good interobserver agreement on grades for CDI (κ = 0.76) and ultrasound (κ = 0.80) assessments. PE values on CEUS and wall thickness showed good association with the Spearman rank correlation coefficient for the entire population (ρ = 0.62, p < 0.01) and for the concordant group (ρ = 0.70, p < 0.01). Multiclass ROC analyses of the concordant group using wall thickness alone as the reference standard showed cutoff points of 18.2 dB for differentiating mild versus moderate activity (sensitivity, 89.0% and specificity, 87.0%) and 23.0 dB for differentiating moderate versus severe (sensitivity, 90% and specificity, 86.8%). Almost identical cutoff points were observed when using ultrasound global assessment as the reference standard: using 18.2 dB to differentiate mild versus moderate activity yielded sensitivity of 89.2% and specificity of 90.9% and using 22.9 dB to differentiate moderate versus severe activity yielded sensitivity of 89.5% and specificity of 83.1%. Quantitative CEUS parameters integrated into inflammatory assessments with ultrasound reduce indeterminate results and improve disease activity level determinations.

  4. Anatomic and functional outcomes of pharmacomechanical and catheter-directed thrombolysis of iliofemoral deep venous thrombosis.

    PubMed

    Hager, Eric; Yuo, Theodore; Avgerinos, Efthymios; Naddaf, Abdullah; Jeyabalan, Geetha; Marone, Luke; Chaer, Rabih

    2014-07-01

    Pharmacomechanical thrombolysis (PMT) and catheter-directed thrombolysis (CDT) are commonly used for the treatment of iliofemoral deep venous thrombosis (DVT). The purpose of this study was to examine the short- and long-term venous patency and venous valvular function as well as clinical outcomes of patients treated for iliofemoral DVT by PMT and CDT. A retrospective review of all patients with symptomatic DVT treated between 2006 and 2011 with PMT or CDT was performed. All patients were treated by local tissue plasminogen activator delivered with PMT or CDT. Patients were divided into two groups on the basis of initial treatment modality: patients treated by PMT alone (group 1), and those who underwent PMT and CDT or CDT alone (group 2). Group comorbidities, initial presenting symptoms, and Clinical, Etiologic, Anatomic, and Pathologic (CEAP) classification scores were compared. Postprocedural duplex ultrasound was used to assess valve function and treated vein patency rates. At all visits, Villalta and CEAP scores were recorded and compared. Group demographic and procedural results were analyzed by Fisher exact test for dichotomous variables and Kruskal-Wallis equality-of-populations rank test for the ordinal and continuous data. Kaplan-Meier survival estimates were used to assess preserved valve function as well as primary and secondary patency rates. There were 79 patients with 102 limbs treated for extensive iliofemoral DVT (median age, 51.5 years; range, 16.6-83.8 years). There were 18 patients in group 1 and 61 patients in group 2 (PMT + CDT [n = 54] or CDT alone [n = 7]). There were no differences in demographics or comorbidities between groups aside from malignant disease, which was more common in group 1 (35.3% vs 11.5%; P = .03). A total of 102 limbs were analyzed, 24 in group 1 and 78 in group 2. Patients in group 1 had a shorter symptom duration compared with group 2 (7 days vs 16 days; P = .011). The median number of procedures in group 1 was lower than in group 2 (P < .001). At last clinical follow-up, there was no significant difference between the Villalta and CEAP scores or the rate of clinical improvement in symptoms between groups. By Kaplan-Meier analysis, there was no difference in primary patency, secondary patency, and treated valve function at 48 months. This study suggests that PMT as a stand-alone therapy is as effective as CDT with or without PMT in preserving valve function and preventing postthrombotic syndrome. Long-term physiologic and functional outcomes are comparable between the modalities, with preserved venous valve function in the majority of patients. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. Stably engineered nanobubbles and ultrasound - An effective platform for enhanced macromolecular delivery to representative cells of the retina.

    PubMed

    Thakur, Sachin S; Ward, Micheal S; Popat, Amirali; Flemming, Nicole B; Parat, Marie-Odile; Barnett, Nigel L; Parekh, Harendra S

    2017-01-01

    Herein we showcase the potential of ultrasound-responsive nanobubbles in enhancing macromolecular permeation through layers of the retina, ultimately leading to significant and direct intracellular delivery; this being effectively demonstrated across three relevant and distinct retinal cell lines. Stably engineered nanobubbles of a highly homogenous and echogenic nature were fully characterised using dynamic light scattering, B-scan ultrasound and transmission electron microscopy (TEM). The nanobubbles appeared as spherical liposome-like structures under TEM, accompanied by an opaque luminal core and darkened corona around their periphery, with both features indicative of efficient gas entrapment and adsorption, respectively. A nanobubble +/- ultrasound sweeping study was conducted next, which determined the maximum tolerated dose for each cell line. Detection of underlying cellular stress was verified using the biomarker heat shock protein 70, measured before and after treatment with optimised ultrasound. Next, with safety to nanobubbles and optimised ultrasound demonstrated, each human or mouse-derived cell population was incubated with biotinylated rabbit-IgG in the presence and absence of ultrasound +/- nanobubbles. Intracellular delivery of antibody in each cell type was then quantified using Cy3-streptavidin. Nanobubbles and optimised ultrasound were found to be negligibly toxic across all cell lines tested. Macromolecular internalisation was achieved to significant, yet varying degrees in all three cell lines. The results of this study pave the way towards better understanding mechanisms underlying cellular responsiveness to ultrasound-triggered drug delivery in future ex vivo and in vivo models of the posterior eye.

  6. Stably engineered nanobubbles and ultrasound - An effective platform for enhanced macromolecular delivery to representative cells of the retina

    PubMed Central

    Thakur, Sachin S.; Ward, Micheal S.; Popat, Amirali; Flemming, Nicole B.; Parat, Marie-Odile; Barnett, Nigel L.

    2017-01-01

    Herein we showcase the potential of ultrasound-responsive nanobubbles in enhancing macromolecular permeation through layers of the retina, ultimately leading to significant and direct intracellular delivery; this being effectively demonstrated across three relevant and distinct retinal cell lines. Stably engineered nanobubbles of a highly homogenous and echogenic nature were fully characterised using dynamic light scattering, B-scan ultrasound and transmission electron microscopy (TEM). The nanobubbles appeared as spherical liposome-like structures under TEM, accompanied by an opaque luminal core and darkened corona around their periphery, with both features indicative of efficient gas entrapment and adsorption, respectively. A nanobubble +/- ultrasound sweeping study was conducted next, which determined the maximum tolerated dose for each cell line. Detection of underlying cellular stress was verified using the biomarker heat shock protein 70, measured before and after treatment with optimised ultrasound. Next, with safety to nanobubbles and optimised ultrasound demonstrated, each human or mouse-derived cell population was incubated with biotinylated rabbit-IgG in the presence and absence of ultrasound +/- nanobubbles. Intracellular delivery of antibody in each cell type was then quantified using Cy3-streptavidin. Nanobubbles and optimised ultrasound were found to be negligibly toxic across all cell lines tested. Macromolecular internalisation was achieved to significant, yet varying degrees in all three cell lines. The results of this study pave the way towards better understanding mechanisms underlying cellular responsiveness to ultrasound-triggered drug delivery in future ex vivo and in vivo models of the posterior eye. PMID:28542473

  7. Acoustically active liposome-nanobubble complexes for enhanced ultrasonic imaging and ultrasound-triggered drug delivery.

    PubMed

    Nguyen, An T; Wrenn, Steven P

    2014-01-01

    Ultrasound is well known as a safe, reliable imaging modality. A historical limitation of ultrasound, however, was its inability to resolve structures at length scales less than nominally 20 µm, which meant that classical ultrasound could not be used in applications such as echocardiography and angiogenesis where one requires the ability to image small blood vessels. The advent of ultrasound contrast agents, or microbubbles, removed this limitation and ushered in a new wave of enhanced ultrasound applications. In recent years, the microbubbles have been designed to achieve yet another application, namely ultrasound-triggered drug delivery. Ultrasound contrast agents are thus tantamount to 'theranostic' vehicles, meaning they can do both therapy (drug delivery) and imaging (diagnostics). The use of ultrasound contrast agents as drug delivery vehicles, however, is perhaps less than ideal when compared to traditional drug delivery vehicles (e.g., polymeric microcapsules and liposomes) which have greater drug carrying capacities. The drawback of the traditional drug delivery vehicles is that they are not naturally acoustically active and cannot be used for imaging. The notion of a theranostic vehicle is sufficiently intriguing that many attempts have been made in recent years to achieve a vehicle that combines the echogenicity of microbubbles with the drug carrying capacity of liposomes. The attempts can be classified into three categories, namely entrapping, tethering, and nesting. Of these, nesting is the newest-and perhaps the most promising. © 2014 Wiley Periodicals, Inc.

  8. Molecular mechanisms of the effect of ultrasound on the fibrinolysis of clots

    PubMed Central

    Chernysh, Irina N.; Everbach, E. Carr; Purohit, Prashant K.; Weisel, John W.

    2016-01-01

    Summary Background Ultrasound accelerates tissue-type plasminogen activator (t-PA)-induced fibrinolysis of clots in vitro and in vivo. Objective To identify mechanisms for the enhancement of t-PA-induced fibrinolysis of clots. Methods Turbidity is an accurate and convenient method, not previously used, to follow the effects of ultrasound. Deconvolution microscopy was used to determine changes in structure, while fluorescence recovery after photobleaching was used to characterize the kinetics of binding/unbinding and transport. Results The ultrasound pulse repetition frequency affected clot lysis times, but there were no thermal effects. Ultrasound in the absence of t-PA produced a slight but consistent decrease in turbidity, suggesting a decrease in fibrin diameter due solely to the action of the ultrasound, likely caused by an increase in protofibril tension because of vibration from ultrasound. Changes in fibrin network structure during lysis with ultrasound were visualized in real time by deconvolution microscopy, revealing that the network becomes unstable when 30–40% of the protein in the network was digested, whereas without ultrasound, the fibrin network was digested gradually and retained structural integrity. Fluorescence recovery after photobleaching during lysis revealed that the off-rate of oligomers from digesting fibers was not much affected but the number of binding/unbinding sites was increased. Conclusions Ultrasound causes a decrease in the diameter of the fibers due to tension as a result of vibration, leading to increased binding sites for plasmin(ogen)/t-PA. The positive feedback of this structural change together with increased mixing/transport of t-PA/plasmin(ogen) is likely to account for the observed enhancement of fibrinolysis by ultrasound. PMID:25619618

  9. Diagnostic Performance of Wells Score Combined With Point-of-care Lung and Venous Ultrasound in Suspected Pulmonary Embolism.

    PubMed

    Nazerian, Peiman; Volpicelli, Giovanni; Gigli, Chiara; Becattini, Cecilia; Sferrazza Papa, Giuseppe Francesco; Grifoni, Stefano; Vanni, Simone

    2017-03-01

    Lung and venous ultrasound are bedside diagnostic tools increasingly used in the early diagnostic approach of suspected pulmonary embolism (PE). However, the possibility of improving the conventional prediction rule for PE by integrating ultrasound has never been investigated. We performed lung and venous ultrasound in consecutive patients suspected of PE in four emergency departments. Conventional Wells score (Ws) was adjudicated by the attending physician, and ultrasound was performed by one of 20 investigators. Signs of deep venous thrombosis (DVT) at venous ultrasound and signs of pulmonary infarcts or alternative diagnoses at lung ultrasound were considered to recalculate two items of the Ws: signs and symptoms of DVT and alternative diagnosis less likely than PE. The diagnostic performances of the ultrasound-enhanced Ws (USWs) and Ws were then compared after confirmation of the final diagnosis. A total of 446 patients were studied. PE was confirmed in 125 patients (28%). USWs performed significantly better than Ws, with a sensitivity of 69.6% versus 57.6% and a specificity of 88.2% versus 68.2%. In combination with D-dimer, USWs showed an optimal failure rate (0.8%) and a significantly superior efficiency than Ws (32.3% vs. 27.2%). A strategy based on lung and venous ultrasound combined with D-dimer would allow to avoid CT pulmonary angiography in 50.5% of patients with suspected PE, compared to 27.2% when the rule without ultrasound is applied. A pretest risk stratification enhanced by ultrasound of lung and venous performs better than Ws in the early diagnostic process of PE. © 2016 by the Society for Academic Emergency Medicine.

  10. Photo-Acoustic Ultrasound Imaging to Distinguish Benign from Malignant Prostate Cancer

    DTIC Science & Technology

    2016-09-01

    from the inside out. Ultrasound imaging provides a basic view of the structure of the prostate while photoacoustic contrast is predicted to enhance...University Page 2 of 13 1. INTRODUCTION: Ultrasound imaging uses sound waves at frequencies above the human hearing range to image organs within the body...An ultrasound transducer delivers a pulse of acoustic energy into the area of interest and listens for the echoes which return as the sound waves

  11. Quality-related enzymes in plant-based products: effects of novel food-processing technologies part 3: ultrasonic processing.

    PubMed

    Terefe, Netsanet Shiferaw; Buckow, Roman; Versteeg, Cornelis

    2015-01-01

    High-power ultrasound is a versatile technology which can potentially be used in many food processing applications including food preservation. This is part 2 of a series of review articles dealing with the effectiveness of nonthermal food processing technologies in food preservation focusing on their effect on enzymes. Typically, ultrasound treatment alone does not efficiently cause microbial or enzyme inactivation sufficient for food preservation. However, combined with mild heat with or without elevated pressure (P ≤ 500 kPa), ultrasound can effectively inactivate enzymes and microorganisms. Synergistic effects between ultrasound and mild heat have been reported for the inactivation of both enzymes and microorganisms. The application of ultrasound has been shown to enhance the rate of inactivation of quality degrading enzymes including pectin methylesterase (PME), polygalacturonase (PG), peroxidase (POD), polyphenol oxidase (PPO), and lipoxygenase (LOX) at mild temperature by up to 400 times. Moreover, ultrasound enables the inactivation of relatively heat-resistant enzymes such as tomato PG1 and thermostable orange PME at mild temperature conditions. The extent to which ultrasound enhances the inactivation rate depends on the type of enzyme, the medium in which the enzyme is suspended, and the processing condition including frequency, ultrasonic intensity, temperature, and pressure. The physical and chemical effects of cavitation are considered to be responsible for the ultrasound-induced inactivation of enzymes, although the dominant mechanism depends on the structure of the enzyme.

  12. Contrast-enhanced intravascular ultrasound pulse sequences for bandwidth-limited transducers.

    PubMed

    Maresca, David; Renaud, Guillaume; van Soest, Gijs; Li, Xiang; Zhou, Qifa; Shung, K Kirk; de Jong, Nico; van der Steen, Antonius F W

    2013-04-01

    We demonstrate two methods for vasa vasorum imaging using contrast-enhanced intravascular ultrasound, which can be performed using commercial catheters. Plaque neovascularization was recognized as an independent marker of coronary artery plaque vulnerability. IVUS-based methods to image the microvessels available to date require high bandwidth (-6 dB relative frequency bandwidth >70%), which are not routinely available commercially. We explored the potential of ultraharmonic imaging and chirp reversal imaging for vasa vasorum imaging. In vitro recordings were performed on a tissue-mimicking phantom using a commercial ultrasound contrast agent and a transducer with a center frequency of 34 MHz and a -6 dB relative bandwidth of 56%. Acoustic peak pressures <500 kPa were used. A tissue-mimicking phantom with channels down to 200 μm in diameter was successfully imaged by the two contrast detection sequences while the smallest channel stayed invisible in conventional intravascular ultrasound images. Ultraharmonic imaging provided the best contrast agent detection. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  13. Focusing of ferroelectret air-coupled ultrasound transducers

    NASA Astrophysics Data System (ADS)

    Gaal, Mate; Bartusch, Jürgen; Dohse, Elmar; Schadow, Florian; Köppe, Enrico

    2016-02-01

    Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers.

  14. Therapeutic management of acute pulmonary embolism.

    PubMed

    Tromeur, Cécile; Van Der Pol, Liselotte M; Couturaud, Francis; Klok, Frederikus A; Huisman, Menno V

    2017-08-01

    Acute pulmonary embolism (PE) is a potentially fatal manifestation of venous thromboembolism. Prompt anticoagulant treatment is crucial for PE patients, which can decrease morbidity and mortality. Risk assessment is the cornerstone of the therapeutic management of PE. It guides physicians to the most appropriate treatment and selects patients for early discharge or home treatment. Areas covered: Here, we review the current treatments of acute PE according to contemporary risk stratification strategies, highlighting each step of PE therapeutic management. Expert commentary: Currently, direct oral anticoagulants (DOACs) represent the first-line therapy of patients presenting with non-high risk PE with a better risk-benefit ratios than vitamin K antagonists (VKAs) due to lower risk of major bleeding. Only high-risk patients with PE who present in shock should be treated with systematic thrombolysis, while surgical thrombectomy or catheter direct thrombolysis (CDT) should only be considered when thrombolysis is contraindicated because of too high bleeding risk.

  15. Thrombolysis for stroke in pregnancy at 39 weeks gestation with a subsequent normal delivery.

    PubMed

    Ritchie, Joanne; Lokman, Mariam; Panikkar, Jane

    2015-08-11

    Stroke during pregnancy is fortunately a rare event, however, it can have severe consequences, with 9.5% of all maternal deaths being related to stroke. The most common presentation is an ischaemic stroke. There has been much debate as to the correct treatment for such cases' and whether thrombolysis can be used safely in pregnancy. Our case describes a 28-year-old woman with a previous normal vaginal delivery presenting in her third trimester with a sudden onset of dense left hemiparesis. She was successfully treated with alteplase, an intravenous recombinant tissue-type plasminogen activator, and made a full recovery after normal delivery of a healthy infant. This case report highlights one of the first documented successful outcomes from thrombolysis for this condition in the UK and may help inform future management of these women. 2015 BMJ Publishing Group Ltd.

  16. Research on respiratory motion correction method based on liver contrast-enhanced ultrasound images of single mode

    NASA Astrophysics Data System (ADS)

    Zhang, Ji; Li, Tao; Zheng, Shiqiang; Li, Yiyong

    2015-03-01

    To reduce the effects of respiratory motion in the quantitative analysis based on liver contrast-enhanced ultrasound (CEUS) image sequencesof single mode. The image gating method and the iterative registration method using model image were adopted to register liver contrast-enhanced ultrasound image sequences of single mode. The feasibility of the proposed respiratory motion correction method was explored preliminarily using 10 hepatocellular carcinomas CEUS cases. The positions of the lesions in the time series of 2D ultrasound images after correction were visually evaluated. Before and after correction, the quality of the weighted sum of transit time (WSTT) parametric images were also compared, in terms of the accuracy and spatial resolution. For the corrected and uncorrected sequences, their mean deviation values (mDVs) of time-intensity curve (TIC) fitting derived from CEUS sequences were measured. After the correction, the positions of the lesions in the time series of 2D ultrasound images were almost invariant. In contrast, the lesions in the uncorrected images all shifted noticeably. The quality of the WSTT parametric maps derived from liver CEUS image sequences were improved more greatly. Moreover, the mDVs of TIC fitting derived from CEUS sequences after the correction decreased by an average of 48.48+/-42.15. The proposed correction method could improve the accuracy of quantitative analysis based on liver CEUS image sequences of single mode, which would help in enhancing the differential diagnosis efficiency of liver tumors.

  17. Enhanced therapeutic anti-inflammatory effect of betamethasone on topical administration with low-frequency, low-intensity (20 kHz, 100 mW/cm(2)) ultrasound exposure on carrageenan-induced arthritis in a mouse model.

    PubMed

    Cohen, Gadi; Natsheh, Hiba; Sunny, Youhan; Bawiec, Christopher R; Touitou, Elka; Lerman, Melissa A; Lazarovici, Philip; Lewin, Peter A

    2015-09-01

    The purpose of this work was to investigate whether low-frequency, low-intensity (20 kHz, <100 mW/cm(2), spatial-peak, temporal-peak intensity) ultrasound, delivered with a lightweight (<100 g), tether-free, fully wearable, battery-powered applicator, is capable of reducing inflammation in a mouse model of rheumatoid arthritis. The therapeutic, acute, anti-inflammatory effect was estimated from the relative swelling induced in mice hindlimb paws. In an independent, indirect approach, the inflammation was bio-imaged by measuring glycolytic activity with near-infrared labeled 2-deoxyglucose. The outcome of the experiments indicated that the combination of ultrasound exposure and topical application of 0.1% (w/w) betamethasone gel resulted in statistically significantly (p < 0.05) enhanced anti-inflammatory activity in comparison with drug or ultrasound treatment alone. The present study underscores the potential benefits of low-frequency, low-intensity ultrasound-assisted drug delivery. However, the proof of concept presented indicates the need for additional experiments to systematically evaluate and optimize the potential of, and the conditions for, tolerable low-frequency, low-intensity ultrasound-promoted non-invasive drug delivery. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Performance Evaluation of Adaptive Imaging Based on Multiphase Apodization with Cross-correlation: A Pilot Study in Abdominal Ultrasound.

    PubMed

    Shin, Junseob; Chen, Yu; Malhi, Harshawn; Chen, Frank; Yen, Jesse

    2018-05-01

    Degradation of image contrast caused by phase aberration, off-axis clutter, and reverberation clutter remains one of the most important problems in abdominal ultrasound imaging. Multiphase apodization with cross-correlation (MPAX) is a novel beamforming technique that enhances ultrasound image contrast by adaptively suppressing unwanted acoustic clutter. MPAX employs multiple pairs of complementary sinusoidal phase apodizations to intentionally introduce grating lobes that can be used to derive a weighting matrix, which mostly preserves the on-axis signals from tissue but reduces acoustic clutter contributions when multiplied with the beamformed radio-frequency (RF) signals. In this paper, in vivo performance of the MPAX technique was evaluated in abdominal ultrasound using data sets obtained from 10 human subjects referred for abdominal ultrasound at the USC Keck School of Medicine. Improvement in image contrast was quantified, first, by the contrast-to-noise ratio (CNR) and, second, by the rating of two experienced radiologists. The MPAX technique was evaluated for longitudinal and transverse views of the abdominal aorta, the inferior vena cava, the gallbladder, and the portal vein. Our in vivo results and analyses demonstrate the feasibility of the MPAX technique in enhancing image contrast in abdominal ultrasound and show potential for creating high contrast ultrasound images with improved target detectability and diagnostic confidence.

  19. Time-reversal Techniques in Ultrasound-assisted Convection-enhanced Drug Delivery to the Brain: Technology Development and In Vivo Evaluation

    PubMed Central

    Lewis, George K.; Guarino, Sabrina; Gandhi, Gaurav; Filinger, Laurent; Lewis, George K.; Olbricht, Willam L.; Sarvazyan, Armen

    2011-01-01

    We describe a drug delivery method that combines Time-Reversal Acoustics (TRA) with Convection-Enhanced Delivery (CED) to improve the delivery of therapeutics to the interstitium of the brain. The Ultrasound-assisted CED approach (UCED) circumvents the blood-brain barrier by infusing compounds through a cannula that is inserted into the brain while simultaneously delivering ultrasound to improve the penetration of pharmaceuticals. CED without ultrasound-assistance has been used to treat a variety of neural disorders, including glioblastoma multiforme, a malignancy that presents a very poor prognosis for patients. We describe a novel system that is used to infuse fluids into the brain parenchyma while simultaneously exposing the tissue to safe levels of 1-MHz, low intensity, ultrasound energy. The system includes a combined infusion needle-hydrophone, a 10-channel ultralow-output impedance amplifier, a broad-band ultrasound resonator, and MatLab®-based TRA control and user-interface. TRA allows easy coupling of ultrasound therapy through the skull without complex phase-correction and array design. The smart targeting UCED system has been tested in vivo and results show it provides 1.5-mm spatial resolution for UCED and improves tracer distribution in the brain over CED alone. PMID:21881622

  20. Successful strategies for integrating bedside ultrasound into undergraduate medical education.

    PubMed

    Palma, James K

    2015-04-01

    Nearly all physician specialties currently utilize bedside ultrasound, and its applications continue to expand. Bedside ultrasound is becoming a core skill for physicians; as such, it should be taught during undergraduate medical education. When ultrasound is integrated in a longitudinal manner beginning in the preclerkship phase of medical school, it not only enhances teaching the basic science topics of anatomy, physiology, and pathology but also ties those skills and knowledge to the clerkship phase and medical decision-making. Bedside ultrasound is a natural bridge from basic science to clinical science. The Uniformed Services University of the Health Sciences, F. Edward Hébert School of Medicine is currently in its fourth year of implementing an integrated ultrasound curriculum in the school of medicine. In our experience, successful integration of a bedside ultrasound curriculum should: align with unique focuses of a medical schools' mission, simplify complex anatomy through multimodal teaching, correlate to teaching of the physical examination, solidify understanding of physiology and pathology, directly link to other concurrent content, narrow differential diagnoses, enhance medical decision-making, improve procedural skills, match to year-group skillsets, develop teaching and leadership abilities, and have elective experiences for advanced topics. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  1. Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification.

    PubMed

    Jiang, Jue; Shang, Xu; Wang, Hua; Xu, Yong-Bo; Gao, Ya; Zhou, Qi

    2015-03-01

    The aim of this study was to investigate the diagnostic values of conventional ultrasound and contrast-enhanced ultrasound (CEUS) in benign and malignant thyroid nodules with calcification. Conventional ultrasound and CEUS were performed in 122 patients with thyroid nodules with calcification. The thyroid nodules were characterized as benign or malignant by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of the two imaging methods were determined. The area under the receiver operating characteristics curve (AUC) was used to assess the diagnostic values of the two imaging methods. In 122 cases of thyroid nodules with calcification, 73 benign nodules and 49 malignant nodules were verified by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of conventional ultrasound were 50%, 77%, 59%, 69%, and 66%, respectively, and those of CEUS were 90%, 92%, 88%, 93%, and 91%, respectively. There were significant differences between the two imaging methods. AUCs of conventional ultrasound and CEUS were 0.628 ± 0.052 and 0.908 ± 0.031, suggesting low and high diagnostic values, respectively. CEUS has high diagnostic values, being significantly greater than those of conventional ultrasound, in differential diagnosis of benign and malignant thyroid nodules with calcification. Copyright © 2014. Published by Elsevier Taiwan.

  2. Drug-Loaded Nanoemulsions/Microbubbles for Combined Tumor Imaging and Therapy

    NASA Astrophysics Data System (ADS)

    Rapoport, Natalya; Gao, Zhonggao; Kennedy, Ann

    2007-05-01

    A new class of multifunctional nanoparticles that combine properties of polymeric drug carriers, ultrasound imaging contrast agents, and enhancers of ultrasound-mediated intracellular drug delivery was developed. At room temperature, the developed systems comprise perfluorocarbon nanodroplets stabilized by the walls made of biodegradable block copolymers. The nanodroplets convert into microbubbles upon heating to physiological temperatures. The phase state of the systems and nanodroplet size may be controlled by the copolymer/perfluorocarbon volume ratio. Three areas observed in phase diagrams correspond to micelles; micelle/microbubble coexistence; and nano/microbubble coexistence. These systems manifest a relatively high drug loading capacity (about 15 % wt/wt). As indicated by biodistribution measurements and ultrasound imaging, the micelles and nanobubbles extravasate selectively into the tumor interstitia. Microbubble cavitate and collapse under the action of tumor-directed ultrasound, resulting in a dramatically enhanced intracellular drug uptake by the tumor cells. Upon intravenous injections, a long-lasting, strong and selective ultrasound contrast is observed in the tumor volume confirming nanobubble extravasation through the defected tumor microvasculature and suggesting their coalescence into larger, highly echogenic microbubbles in the tumor tissue. This effect is tumor-selective; no accumulation of echogenic microbubbles is observed in other organs. Tumor contrast increases in time confirming gradual accumulation of echogenic microbubbles in the tumor tissue, presumably via the enhanced penetration and retention (EPR) effect.

  3. Contrast-enhanced and targeted ultrasound.

    PubMed

    Postema, Michiel; Gilja, Odd Helge

    2011-01-07

    Ultrasonic imaging is becoming the most popular medical imaging modality, owing to the low price per examination and its safety. However, blood is a poor scatterer of ultrasound waves at clinical diagnostic transmit frequencies. For perfusion imaging, markers have been designed to enhance the contrast in B-mode imaging. These so-called ultrasound contrast agents consist of microscopically small gas bubbles encapsulated in biodegradable shells. In this review, the physical principles of ultrasound contrast agent microbubble behavior and their adjustment for drug delivery including sonoporation are described. Furthermore, an outline of clinical imaging applications of contrast-enhanced ultrasound is given. It is a challenging task to quantify and predict which bubble phenomenon occurs under which acoustic condition, and how these phenomena may be utilized in ultrasonic imaging. Aided by high-speed photography, our improved understanding of encapsulated microbubble behavior will lead to more sophisticated detection and delivery techniques. More sophisticated methods use quantitative approaches to measure the amount and the time course of bolus or reperfusion curves, and have shown great promise in revealing effective tumor responses to anti-angiogenic drugs in humans before tumor shrinkage occurs. These are beginning to be accepted into clinical practice. In the long term, targeted microbubbles for molecular imaging and eventually for directed anti-tumor therapy are expected to be tested.

  4. Contrast-enhanced and targeted ultrasound

    PubMed Central

    Postema, Michiel; Gilja, Odd Helge

    2011-01-01

    Ultrasonic imaging is becoming the most popular medical imaging modality, owing to the low price per examination and its safety. However, blood is a poor scatterer of ultrasound waves at clinical diagnostic transmit frequencies. For perfusion imaging, markers have been designed to enhance the contrast in B-mode imaging. These so-called ultrasound contrast agents consist of microscopically small gas bubbles encapsulated in biodegradable shells. In this review, the physical principles of ultrasound contrast agent microbubble behavior and their adjustment for drug delivery including sonoporation are described. Furthermore, an outline of clinical imaging applications of contrast-enhanced ultrasound is given. It is a challenging task to quantify and predict which bubble phenomenon occurs under which acoustic condition, and how these phenomena may be utilized in ultrasonic imaging. Aided by high-speed photography, our improved understanding of encapsulated microbubble behavior will lead to more sophisticated detection and delivery techniques. More sophisticated methods use quantitative approaches to measure the amount and the time course of bolus or reperfusion curves, and have shown great promise in revealing effective tumor responses to anti-angiogenic drugs in humans before tumor shrinkage occurs. These are beginning to be accepted into clinical practice. In the long term, targeted microbubbles for molecular imaging and eventually for directed anti-tumor therapy are expected to be tested. PMID:21218081

  5. Frequency-dependent ultrasound-induced transformation in E. coli.

    PubMed

    Deeks, Jeremy; Windmill, James; Agbeze-Onuma, Maduka; Kalin, Robert M; Argondizza, Peter; Knapp, Charles W

    2014-12-01

    Ultrasound-enhanced gene transfer (UEGT) is continuing to gain interest across many disciplines; however, very few studies investigate UEGT efficiency across a range of frequencies. Using a variable frequency generator, UEGT was tested in E. coli at six ultrasonic frequencies. Results indicate frequency can significantly influence UEGT efficiency positively and negatively. A frequency of 61 kHz improved UEGT efficiency by ~70 % higher, but 99 kHz impeded UEGT to an extent worse than no ultrasound exposure. The other four frequencies (26, 133, 174, and 190 kHz) enhanced transformation compared to no ultrasound, but efficiencies did not vary. The influence of frequency on UEGT efficiency was observed across a range of operating frequencies. It is plausible that frequency-dependent dynamics of mechanical and chemical energies released during cavitational-bubble collapse (CBC) are responsible for observed UEGT efficiencies.

  6. Advanced devices for photoacoustic imaging to improve cancer and cerebrovascular medicine

    NASA Astrophysics Data System (ADS)

    Montilla Marien, Leonardo Gabriel

    Recent clinical studies have demonstrated that photoacoustic imaging (PAI) provides important diagnostic information for breast cancer staging. Despite these promising studies, PAI remains an unfeasible option for clinics due to the cost to implement, the required large modification in user conduct and the inflexibility of the hardware to accommodate other applications for the incremental enhancement in diagnostic information. The research described in this dissertation addresses these issues by designing attachments to clinical ultrasound probes and incorporating custom detectors into commercial ultrasound scanners. The ultimate benefit of these handheld devices is to expand the capability of current ultrasound systems and facilitate the translation of PAI to enhance cancer diagnostics and neurosurgical outcomes. Photoacoustic enabling devices (PEDs) were designed as attachments to two clinical ultrasound probes optimized for breast cancer diagnostics. PAI uses pulsed laser excitation to create transient heating (<1°C) and thermoelastic expansion that is detected as an ultrasonic emission. These ultrasonic emissions are remotely sensed to construct noninvasive images with optical contrast at depths much greater than other optical modalities. The PEDs are feasible in terms of cost, user familiarity and flexibility for various applications. Another possible application for PAI is in assisting neurosurgeons treating aneurysms. Aneurysms are often treated by placing a clip to prevent blood flow into the aneurysm. However, this procedure has risks associated with damaging nearby vessels. One of the developed PEDs demonstrated the feasibility to three-dimensionally image tiny microvasculature (<0.3mm) beyond large blood occlusions (>2.4mm) in a phantom model. The capability to use this during surgery would suggest decreasing the risks associated with these treatments. However, clinical ultrasound arrays are not clinically feasible for microsurgical applications due to their bulky size and linear scanning requirements for 3D. Therefore, capacitive micromachined ultrasound transducer (CMUT) two-dimensional arrays compatible with standard ultrasound scanners were used to generate real-time 3D photoacoustic images. Future probes, designed incorporating CMUT arrays, would be relatively simple to fabricate and a convenient upgrade to existing clinical ultrasound equipment. Eventually, a handheld tool with the ability to visualize, in real-time 3D, the desired microvasculature, would assist surgical procedures. The potential implications of PAI devices compatible with standard ultrasound equipment would be a streamlined cost efficient solution for translating photoacoustics into clinical practice. The practitioner could then explore the benefits of the enhanced contrast adjunctive to current ultrasound applications. Clinical availability of PAI could enhance breast cancer diagnostics and cerebrovascular surgical outcomes.

  7. TRUST-tPA trial: Telemedicine for remote collaboration with urgentists for stroke-tPA treatment.

    PubMed

    Mazighi, Mikael; Meseguer, Elena; Labreuche, Julien; Miroux, Patrick; Le Gall, Catherine; Roy, Patricia; Tubach, Florence; Amarenco, Pierre

    2017-01-01

    Background Previous observational studies have shown that telemedicine is feasible and safe to deliver intravenous (IV) recombinant tissue plasminogen activator (rt-PA). However, implementation of telemedicine may be challenging. To illustrate this fact, we report a study showing that telemedicine failed to improve clinical outcome and analyze the reasons for this shortcoming. Methods We established a tele-stroke network of 10 emergency rooms (ERs) of community hospitals connected to a stroke center to perform a randomized, open-label clinical trial with blinded outcome evaluation. Eligible patients were randomly assigned to either a usual care arm (i.e. immediate transfer to the stroke center and administration of IV rt-PA if indication was confirmed upon stroke arrival) or tele-thrombolysis arm (i.e. immediate administration of IV rt-PA in ER and transfer to the stroke center). The primary efficacy outcome was an excellent outcome (modified Rankin scale (mRS) 0-1 at 90 days). Secondary endpoints included favorable outcome (90-day mRS 0-2) and early neurological improvement (NIHSS score 0-1 at 24 hours or a decrease of ≥ 4 points within 24 hours). Safety outcomes included symptomatic intracerebral hemorrhage (ICH) per ECASS II definition, any ICH and all-cause mortality. Results During an accrual time of 48 months, because of a slow enrollment rate, only 49 of 270 patients initially planned for inclusion were randomized into usual care ( n = 23) and tele-thrombolysis ( n = 26). Despite random assignment, patients allocated to tele-thrombolysis were older and had more severe stroke than patients allocated to usual care. The median duration of video-conference was 23 minutes in the usual care arm and 73 minutes in the tele-thrombolysis arm. Eighty-four percent of patients in the tele-thrombolysis arm were treated by IV rt-PA in comparison to 18% in the usual care arm. In univariate analysis but not after adjustment for age and baseline NIHSS, patients allocated in the usual care arm had a higher rate of excellent or favorable outcome. There were no differences in safety outcomes, with only one symptomatic ICH occurring in the tele-thrombolysis arm. Conclusions Stroke patients included in the telemedicine arm of the TRUST-tPA trial increased their rt-PA eligibility five-fold. However, the efficacy and safety remains to be determined (ClinicalTrials.org, NCT00279149).

  8. Pulsed high intensity focused ultrasound (pHIFU) enhances delivery of doxorubicin in a preclinical model of pancreatic cancer

    PubMed Central

    Li, Tong; Wang, Yak-Nam; Khokhlova, Tatiana D.; D’Andrea, Samantha; Starr, Frank; Chen, Hong; McCune, Jeannine S.; Risler, Linda J.; Mashadi-Hossein, Afshin; Hwang, Joo Ha

    2015-01-01

    Pancreatic cancer is characterized by extensive stromal desmoplasia which decreases blood perfusion and impedes chemotherapy delivery. Breaking the stromal barrier could both increase perfusion and permeabilize the tumor, enhancing chemotherapy penetration. Mechanical disruption of the stroma can be achieved using ultrasound-induced bubble activity – cavitation. Cavitation is also known to result in microstreaming and could have the added benefit of actively enhancing diffusion into the tumors. Here, we report the ability to enhance chemotherapeutic drug doxorubicin (Dox) penetration using ultrasound-induced cavitation in a genetically engineered mouse model (KPC mouse) of pancreatic ductal adenocarcinoma. To induce localized inertial cavitation in pancreatic tumors, pulsed high intensity focused ultrasound (pHIFU) was used either during or before doxorubicin administration to elucidate the mechanisms of enhanced drug delivery (active versus passive drug diffusion). For both types, the pHIFU exposures which were associated with high cavitation activity resulted in disruption of the highly fibrotic stromal matrix and enhanced the normalized Dox concentration by up to 4.5 fold compared to controls. Furthermore, normalized Dox concentration was associated with the cavitation metrics (p < 0.01), indicating that high and sustained cavitation results in increased chemotherapy penetration. No significant difference between the outcomes of the two types, i.e., Dox infusion during or after pHIFU treatment, was observed, suggesting that passive diffusion into previously permeabilized tissue is the major mechanism for the increase in drug concentration. Together, the data indicate that pHIFU treatment of pancreatic tumors when resulting in high and sustained cavitation can efficiently enhance chemotherapy delivery to pancreatic tumors. PMID:26216548

  9. MR-Guided Pulsed High-Intensity Focused Ultrasound Enhancement of Gene Therapy Combined With Androgen Deprivation and Radiotherapy for Prostate Cancer Treatment

    DTIC Science & Technology

    2009-09-01

    first statement of work is to determine if high intensity focused ultrasound ( HIFU ) increases the cellular uptake of AS-MDM2, AS-bcl-2 and AS-PKA...Drug Delivery in Prostate Tumor in vivo Using MR Guided Focused Ultrasound (MRg HIFU ). WC, IFMBE Proceedings 25: pp341-344, 2009 6...pharmaceutical agents in the treatment target. In the model system proposed, pulsed high intensity focused ultrasound ( HIFU ) is hypothesized to improve

  10. Imaging Performance of a Handheld Ultrasound System With Real-Time Computer-Aided Detection of Lumbar Spine Anatomy: A Feasibility Study.

    PubMed

    Tiouririne, Mohamed; Dixon, Adam J; Mauldin, F William; Scalzo, David; Krishnaraj, Arun

    2017-08-01

    The aim of this study was to evaluate the imaging performance of a handheld ultrasound system and the accuracy of an automated lumbar spine computer-aided detection (CAD) algorithm in the spines of human subjects. This study was approved by the institutional review board of the University of Virginia. The authors designed a handheld ultrasound system with enhanced bone image quality and fully automated CAD of lumbar spine anatomy. The imaging performance was evaluated by imaging the lumbar spines of 68 volunteers with body mass index between 18.5 and 48 kg/m. The accuracy, sensitivity, and specificity of the lumbar spine CAD algorithm were assessed by comparing the algorithm's results to ground-truth segmentations of neuraxial anatomy provided by radiologists. The lumbar spine CAD algorithm detected the epidural space with a sensitivity of 94.2% (95% confidence interval [CI], 85.1%-98.1%) and a specificity of 85.5% (95% CI, 81.7%-88.6%) and measured its depth with an error of approximately ±0.5 cm compared with measurements obtained manually from the 2-dimensional ultrasound images. The spine midline was detected with a sensitivity of 93.9% (95% CI, 85.8%-97.7%) and specificity of 91.3% (95% CI, 83.6%-96.9%), and its lateral position within the ultrasound image was measured with an error of approximately ±0.3 cm. The bone enhancement imaging mode produced images with 5.1- to 10-fold enhanced bone contrast when compared with a comparable handheld ultrasound imaging system. The results of this study demonstrate the feasibility of CAD for assisting with real-time interpretation of ultrasound images of the lumbar spine at the bedside.

  11. Applications of ultrasound to chiral crystallization, resolution and deracemization.

    PubMed

    Xiouras, Christos; Fytopoulos, Antonios; Jordens, Jeroen; Boudouvis, Andreas G; Van Gerven, Tom; Stefanidis, Georgios D

    2018-05-01

    Industrial synthesis of enantiopure compounds is nowadays heavily based on the separation of racemates through crystallization processes. Although the application of ultrasound in solution crystallization processes (sonocrystallization) has become a promising emerging technology, offering several benefits (e.g. reduction of the induction time and narrowing of the metastable zone width, control over the product size, shape and polymorphic modification), little attention has been paid so far to the effects of ultrasound on chiral crystallization processes. Several recent studies have reported on the application of acoustic energy to crystallization processes that separate enantiomers, ranging from classical (diastereomeric) resolution and preferential crystallization to new and emerging processes such as attrition-enhanced deracemization (Viedma ripening). A variety of interesting effects have been observed, which include among others, enhanced crystallization yield with higher enantiomeric purity crystals, spontaneous mirror symmetry breaking crystallization, formation of metastable conglomerate crystals and enhanced deracemization rates. The objective of this review is to provide an overview of the effects of ultrasound on chiral crystallization and outline several aspects of interest in this emerging field. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Overview of the Hemostasis Research Program: Advances and Future Directions

    DTIC Science & Technology

    2004-09-01

    Gauze sponges - Clamps ◆ Noncompressible - Intracavitary hemostatic agent - High Intensity Focused Ultrasound ( HIFU ) - Drugs to enhance hemostatic...7 2.6 High Intensity Focused Ultrasound ( HIFU ) Device In addition to screening potential hemostatic agents, the ISR is currently evaluating...Drugs to Treat Coagulopathy High Intensity Focused Ultrasound Self/Buddy Aid Battalion Surgeon Scenario One: Bullet Wound to Thigh (Femoral

  13. Evaluation of an Innovative Hands-On Anatomy-Centered Ultrasound Curriculum to Supplement Graduate Gross Anatomy Education

    ERIC Educational Resources Information Center

    Royer, Danielle F.; Kessler, Ross; Stowell, Jeffrey R.

    2017-01-01

    Ultrasound (US) can enhance anatomy education, yet is incorporated into few non-medical anatomy programs. This study is the first to evaluate the impact of US training in gross anatomy for non-medical students in the United States. All 32 master's students enrolled in gross anatomy with the anatomy-centered ultrasound (ACUS) curriculum were…

  14. Low-amplitude non-linear volume vibrations of single microbubbles measured with an "acoustical camera".

    PubMed

    Renaud, Guillaume; Bosch, Johan G; Van Der Steen, Antonius F W; De Jong, Nico

    2014-06-01

    Contrast-enhanced ultrasound imaging is based on the detection of non-linear vibrational responses of a contrast agent after its intravenous administration. Improving contrast-enhanced images requires an accurate understanding of the vibrational response to ultrasound of the lipid-coated gas microbubbles that constitute most ultrasound contrast agents. Variations in the volume of microbubbles provide the most efficient radiation of ultrasound and, therefore, are the most important bubble vibrations for medical diagnostic ultrasound imaging. We developed an "acoustical camera" that measures the dynamic volume change of individual microbubbles when excited by a pressure wave. In the work described here, the technique was applied to the characterization of low-amplitude non-linear behaviors of BR14 microbubbles (Bracco Research, Geneva, Switzerland). The amplitude dependence of the resonance frequency and the damping, the prevalence of efficient subharmonic and ultraharmonic vibrations and the amplitude dependence of the response at the fundamental frequency and at the second harmonic frequency were investigated. Because of the large number of measurements, we provide a statistical characterization of the low-amplitude non-linear properties of the contrast agent. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Ultrasound Enhanced Matrix Metalloproteinase-9 Triggered Release of Contents from Echogenic Liposomes

    PubMed Central

    Nahire, Rahul; Paul, Shirshendu; Scott, Michael D.; Singh, Raushan K.; Muhonen, Wallace W.; Shabb, John; Gange, Kara N.; Srivastava, D. K.; Sarkar, Kausik; Mallik, Sanku

    2012-01-01

    The extracellular enzyme matrix metalloproteinase-9 (MMP-9) is overexpressed in atherosclerotic plaques and in metastatic cancers. The enzyme is responsible for rupture of the plaques and for the invasion and metastasis of a large number of cancers. The ability of ultrasonic excitation to induce thermal and mechanical effects has been used to release drugs from different carriers. However, majority of these studies were performed with low frequency ultrasound (LFUS) at kHz frequencies. Clinical usage of LFUS excitations will be limited due to harmful biological effects. Herein, we report our results on the release of encapsulated contents from substrate lipopeptide incorporated echogenic liposomes triggered by recombinant human MMP-9. The contents release was further enhanced by the application of diagnostic frequency (3 MHz) ultrasound. The echogenic liposomes were successfully imaged employing a medical ultrasound transducer (4 – 15 MHz). The conditioned cell culture media from cancer cells (secreting MMP-9) released the encapsulated dye from the liposomes (30 – 50%) and this release is also increased (50 – 80%) by applying diagnostic frequency ultrasound (3 MHz) for 3 minutes. With further developments, these liposomes have the potential to serve as multimodal carriers for triggered release and simultaneous ultrasound imaging. PMID:22849291

  16. Body temperature and outcome after stroke thrombolysis.

    PubMed

    Ernon, L; Schrooten, M; Thijs, V

    2006-07-01

    We studied whether baseline body temperature and temperature increases after stroke adversely affect outcome after thrombolysis with intravenous tissue plasminogen activator (IV tPA). The evolution of body temperature in the first 24 h after treatment with IV tPA was described by calculating the area under the curve of the temperature over time plot relative to temperature at admission (AUCBL) and relative to a standard value of 37 degrees C (AUC37). Temperature parameters were related to functional outcome. The median baseline National Institutes of Health Stroke Scale of 100 consecutive patients was 16 (interquartile range 11-21) and 34 patients had a favourable response to tPA. Patients with an unfavourable outcome had a more important temperature elevation than patients who had a favourable outcome after tPA (+1 degrees C vs +0.6 degrees C, P=0.02), despite similar baseline T and had a higher AUCBL (9.79 vs 5.36, P=0.027) and more frequently showed hyperthermia relative to baseline (82% vs 56%, P=0.011). After adjustment for baseline characteristics, the presence of hyperthermia relative to baseline was associated with a reduced odds of good outcome after thrombolysis (OR 0.34, 95% CI 0.10-0.95, P=0.040). Hyperthermia relative to baseline temperature in the 24 h after intravenous thrombolysis is associated with an unfavourable outcome.

  17. MRI based thrombolysis for FLAIR-negative stroke patients within 4.5-6h after symptom onset.

    PubMed

    Wei, Xiao-Er; Zhou, Jia; Li, Wen-Bin; Zhao, Yu-Wu; Li, Ming-Hua; Li, Yue-Hua

    2017-01-15

    To investigate the feasibility of DWI-FLAIR mismatch in identifying patients who might benefit from thrombolytic therapy within 4.5-6h, we analyzed the data of 105 ischemic stroke patients with known time of symptom onset who underwent MRI within 6h of stroke and thrombolysis between December 2006 and December 2013. They were divided into three groups: symptom onset within 4.5h (n=66); 4.5-6h and FLAIR images negative (n=9); and 4.5-6h and FLAIR images positive (n=30). Outcome of thrombolysis was assessed for each group by recanalization rate, National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores. The results showed that mismatch between positive DWI and negative FLAIR images identified patients within 4.5h of symptom onset with sensitivity, specificity, positive predictive value and negative predictive value of 40.9%, 76.9%, and 75% and 43.5%. Recanalization rate, NIHSS score and mRS score were all better in both the 0-4.5h and 4.5-6h FLAIR-negative groups than in the 4.5-6h FLAIR-positive group (p<0.05). These data demonstrate that within 4.5-6h of symptom onset, patients with negative FLAIR images may benefit from thrombolysis therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Oxygen therapy reduces secondary hemorrhage after thrombolysis in thromboembolic cerebral ischemia.

    PubMed

    Sun, Li; Zhou, Wei; Mueller, Christian; Sommer, Clemens; Heiland, Sabine; Bauer, Alexander T; Marti, Hugo H; Veltkamp, Roland

    2010-09-01

    Hyperbaric oxygen (HBO) and normobaric hyperoxia (NBO) protect the brain parenchyma and the cerebral microcirculation against ischemia. We studied their effect on secondary hemorrhage after thrombolysis in two thromboembolic middle cerebral artery occlusion (MCAO) (tMCAO) models. Beginning 60 minutes after tMCAO with either thrombin-induced thromboemboli (TT) or calcium-induced thromboemboli (CT), spontaneously hypertensive rats (n=96) breathed either air, 100% O(2) (NBO), or 100% O(2) at 3 bar (HBO) for 1 hour. Immediately thereafter, recombinant tissue plasminogen activator (rt-PA, 9 mg/kg) was injected. Although significant reperfusion was observed after thrombolysis in TT-tMCAO, vascular occlusion persisted in CT-tMCAO. In TT-tMCAO, NBO and HBO significantly reduced diffusion-weighted imaging-magnetic resonance imaging (MRI) lesion volume and postischemic blood-brain barrier (BBB) permeability on postcontrast T1-weighted images. NBO and, significantly more potently, HBO reduced macroscopic hemorrhage on T2* MRI and on corresponding postmortem cryosections. Oxygen therapy lowered hemoglobin content and attenuated activation of matrix metalloproteinases in the ischemic hemisphere. In contrast, NBO and HBO failed to reduce infarct size in CT but both decreased BBB damage and microscopic hemorrhagic transformation. Only HBO reduced hemoglobin extravasation in the ischemic hemisphere. In conclusion, NBO and HBO decrease infarct size after thromboembolic ischemia only if recanalization is successful. As NBO and HBO also reduce postthrombolytic intracerebral hemorrhage, combining the two with thrombolysis seems promising.

  19. Partial segmental thrombosis of the corpus cavernosum (PSTCC) diagnosed by contrast-enhanced ultrasound: a case report.

    PubMed

    Sauer, Stephanie; Goltz, Jan P; Gassenmaier, Tobias; Kunz, Andreas S; Bley, Thorsten A; Klein, Detlef; Petritsch, Bernhard

    2014-12-17

    Partial segmental thrombosis of the corpus cavernosum (PSTCC) is a rare disease predominantly occurring in young men. Cardinal symptoms are pain and perineal swelling. Although several risk factors are described in the literature, the exact etiology of penile thrombosis remains unclear in most cases. MRI or ultrasound (US) is usually used for diagnosing this condition. We report a case of penile thrombosis after left-sided varicocele ligature in a young patient. The diagnosis was established using contrast-enhanced ultrasound (CEUS) and was confirmed by contrast-enhanced magnetic resonance imaging (ceMRI). Successful conservative treatment consisted of systemic anticoagulation using low molecular weight heparin and acetylsalicylic acid. PSTCC is a rare condition in young men and appears with massive pain and perineal swelling. In case of suspected PSTCC utilization of CEUS may be of diagnostic benefit.

  20. Ultrasound of the small joints of the hands and feet: current status

    PubMed Central

    2007-01-01

    The aim of this article was to review the current status of ultrasound imaging of patients with rheumatological disorders of the hands and feet. Ultrasound machines with high-resolution surface probes are readily available in most radiology departments and can be used to address important clinical questions posed by the rheumatologist and sports and rehabilitation physician. There is increasing evidence that ultrasound detects synovitis that is silent to clinical examination. Detection and classification of synovitis and the early detection of bone erosions are important in clinical decision making. Ultrasound has many advantages over other imaging techniques with which it is compared, particularly magnetic resonance. The ability to carry out a rapid assessment of many widely spaced joints, coupled with clinical correlation, the ability to move and stress musculoskeletal structures and the use of ultrasound to guide therapy accurately are principal amongst these. The use of colour flow Doppler studies provides a measure of neovascularisation within the synovial lining of joints and tendons, and within tendons themselves, that is not available with other imaging techniques. Disadvantages compared to MRI include small field of view, poor image presentation, and difficulty in demonstrating cartilage and deep joints in their entirety. Contrast-enhanced magnetic resonance provides a better measure of capillary permeability and extracellular fluid than does ultrasound. The ability to image simultaneously multiple small joints in the hands and feet and their enhancement characteristics cannot be matched with ultrasound, though future developments in 3-D ultrasound may narrow this gap. Magnetic resonance provides a more uniform and reproducible image for long-term follow-up studies. PMID:17712556

  1. Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow.

    PubMed

    Morgan, Tara A; Jha, Priyanka; Poder, Liina; Weinstein, Stefanie

    2018-04-09

    Ultrasound is routinely used as the first imaging exam for evaluation of renal transplants and can identify most major surgical complications and evaluate vascularity with color Doppler. Ultrasound is limited, however, in the detection of parenchymal disease processes and Doppler evaluation is also prone to technical errors. Multiple new ultrasound applications have been developed and are under ongoing investigation which could add additional diagnostic capability to the routine ultrasound exam with minimal additional time, cost, and patient risk. Contrast-enhanced ultrasound (CEUS) can be used off-label in the transplant kidney, and can assist in detection of infection, trauma, and vascular complications. CEUS also can demonstrate perfusion of the transplant assessed quantitatively with generation of time-intensity curves. Future directions of CEUS include monitoring treatment response and microbubble targeted medication delivery. Elastography is an ultrasound application that can detect changes in tissue elasticity, which is useful to diagnose diffuse parenchymal disease, such as fibrosis, otherwise unrecognizable with ultrasound. Elastography has been successfully applied in other organs including the liver, thyroid, and breast; however, it is still under development for use in the transplant kidney. Unique properties of the transplant kidney including its heterogeneity, anatomic location, and other technical factors present challenges in the development of reference standard measurements. Lastly, B-flow imaging is a flow application derived from B-mode. This application can show the true lumen size of a vessel which is useful to depict vascular anatomy and bypasses some of the pitfalls of color Doppler such as demonstration of slow flow.

  2. Ultrasound enhanced process for extracting metal species in supercritical fluids

    DOEpatents

    Wai, Chien M.; Enokida, Youichi

    2006-10-31

    Improved methods for the extraction or dissolution of metals, metalloids or their oxides, especially lanthanides, actinides, uranium or their oxides, into supercritical solvents containing an extractant are disclosed. The disclosed embodiments specifically include enhancing the extraction or dissolution efficiency with ultrasound. The present methods allow the direct, efficient dissolution of UO2 or other uranium oxides without generating any waste stream or by-products.

  3. [Application of CO2 enhanced ultrasound for two-stage operation of hepatic tumors].

    PubMed

    Wang, W; Xu, Z; Fan, J

    1996-12-01

    The feasibility of CO2 enhanced ultrasound (CO2-EUS) was evaluated in two-stage operation patients with hepatic tumors. CO2-EUS was carried out in nine patients with indwelling catheter within hepatic artery for two-stage operation of liver cancer. CO2 microbubbles mixing by 5 ml of 5% NaHCO3 and 2.5 ml of 5% Vitamine C were injected into the indwelling catheter. The computed sonography of ACUSON 128XP/10 with a 3.5 MHz convex transducer was used for this study. The enhanced parenchyma of the liver obtained by CO2-EUS and the lasting time of enhancement was about 8 minutes. The hepatic tumors, after chemotherapeutic treatment via indwelling catheter, were variously enhanced by CO2 microbubbles. The enhanced sonogram of the tumors took the forms of hypoechoic, ring-like, or spotty enhanced pattern lasting for more than 30 minutes. The margin of the enhanced tumors was very clear in CO2-EUS. CO2-EUS detected five more lesions (size 1-3 cm) besides 9 lesions by conventional ultrasound. CO2-EUS was extremely useful in evaluating curative effects of tumor, increasing detection rates of small tumor, and improving thoroughness of two-stage operation.

  4. Uterine fibroids: semiquantitative perfusion MR imaging parameters associated with the intraprocedural and immediate postprocedural treatment efficiencies of MR imaging-guided high-intensity focused ultrasound ablation.

    PubMed

    Kim, Young-sun; Kim, Byoung-Gie; Rhim, Hyunchul; Bae, Duk-Soo; Lee, Jeong-Won; Kim, Tae-Joong; Choi, Chel Hun; Lee, Yoo-Young; Lim, Hyo Keun

    2014-11-01

    To determine whether semiquantitative perfusion magnetic resonance (MR) imaging parameters are associated with therapeutic effectiveness of MR imaging-guided high-intensity focused ultrasound ( HIFU high-intensity focused ultrasound ) ablation of uterine fibroids and which semiquantitative perfusion parameters are significant with regard to treatment efficiency. This study was approved by the institutional review board, and informed consent was obtained from all subjects. Seventy-seven women (mean age, 43.3 years) with 119 fibroids (mean diameter, 7.5 cm) treated with MR imaging-guided HIFU high-intensity focused ultrasound ablation were analyzed. The correlation between semiquantitative perfusion MR parameters (peak enhancement, relative peak enhancement, time to peak, wash-in rate, washout rate) and heating and ablation efficiencies (lethal thermal dose volume based on MR thermometry and nonperfused volume based on immediate contrast-enhanced image divided by intended treatment volume) were evaluated by using a linear mixed model on a per-fibroid basis. The specific value of the significant parameter that had a substantial effect on treatment efficiency was determined. The mean peak enhancement, relative peak enhancement, time to peak, wash-in rate, and washout rate of the fibroids were 1293.1 ± 472.8 (range, 570.2-2477.8), 171.4% ± 57.2 (range, 0.6%-370.2%), 137.2 seconds ± 119.8 (range, 20.0-300.0 seconds), 79.5 per second ± 48.2 (range, 12.5-236.7 per second), and 11.4 per second ± 10.1 (range, 0-39.3 per second), respectively. Relative peak enhancement was found to be independently significant for both heating and ablation efficiencies (B = -0.002, P < .001 and B = -0.003, P = .050, respectively). The washout rate was significantly associated with ablation efficiency (B = -0.018, P = .043). Both efficiencies showed the most abrupt transitions at 220% of relative peak enhancement. Relative peak enhancement at semiquantitative perfusion MR imaging was significantly associated with treatment efficiency of MR imaging-guided HIFU high-intensity focused ultrasound ablation of uterine fibroids, and a value of 220% or less is suggested as a screening guideline for more efficient treatment.

  5. Treatment options for severe pulmonary embolism during pregnancy and the postpartum period: a systematic review.

    PubMed

    Martillotti, G; Boehlen, F; Robert-Ebadi, H; Jastrow, N; Righini, M; Blondon, M

    2017-10-01

    Essentials The evidence on how to manage life-threatening pregnancy-related pulmonary embolism (PE) is scarce. We systematically reviewed all available cases of (sub)massive PE until December 2016. Thrombolysis in such severe PE was associated with a high maternal survival (94%). The major bleeding risk was much greater in the postpartum (58%) than antepartum period (18%). Background Massive pulmonary embolism (PE) during pregnancy or the postpartum period is a rare but dramatic event. Our aim was to systematically review the evidence to guide its management. Methods We searched Pubmed, Embase, conference proceedings and the RIETE registry for published cases of severe (submassive/massive) PE treated with thrombolysis, percutaneous or surgical thrombectomy and/or extracorporeal membrane oxygenation (ECMO), occurring during pregnancy or within 6 weeks of delivery. Main outcomes were maternal survival and major bleeding, premature delivery, and fetal survival and bleeding. Results We found 127 cases of severe PE (at least 83% massive; 23% with cardiac arrest) treated with at least one modality. Among 83 women with thrombolysis, survival was 94% (95% CI, 86-98). The risk of major bleeding was 17.5% during pregnancy and 58.3% in the postpartum period, mainly because of severe postpartum hemorrhages. Fetal deaths possibly related to PE or its treatment occurred in 12.0% of cases treated during pregnancy. Among 36 women with surgical thrombectomy, maternal survival and risk of major bleeding were 86.1% (95% CI, 71-95) and 20.0%, with fetal deaths possibly related to surgery in 20.0%. About half of severe postpartum PEs occurred within 24 h of delivery. Conclusions Published cases of thrombolysis for massive PE during pregnancy and the postpartum period suggest a high maternal and fetal survival (94% and 88%). In the postpartum period, given the high risk of major bleeding with thrombolysis, other therapeutic options (catheter [or surgical] thrombectomy, ECMO) may be considered if available. © 2017 International Society on Thrombosis and Haemostasis.

  6. Implicit bias among physicians and its prediction of thrombolysis decisions for black and white patients.

    PubMed

    Green, Alexander R; Carney, Dana R; Pallin, Daniel J; Ngo, Long H; Raymond, Kristal L; Iezzoni, Lisa I; Banaji, Mahzarin R

    2007-09-01

    Studies documenting racial/ethnic disparities in health care frequently implicate physicians' unconscious biases. No study to date has measured physicians' unconscious racial bias to test whether this predicts physicians' clinical decisions. To test whether physicians show implicit race bias and whether the magnitude of such bias predicts thrombolysis recommendations for black and white patients with acute coronary syndromes. An internet-based tool comprising a clinical vignette of a patient presenting to the emergency department with an acute coronary syndrome, followed by a questionnaire and three Implicit Association Tests (IATs). Study invitations were e-mailed to all internal medicine and emergency medicine residents at four academic medical centers in Atlanta and Boston; 287 completed the study, met inclusion criteria, and were randomized to either a black or white vignette patient. IAT scores (normal continuous variable) measuring physicians' implicit race preference and perceptions of cooperativeness. Physicians' attribution of symptoms to coronary artery disease for vignette patients with randomly assigned race, and their decisions about thrombolysis. Assessment of physicians' explicit racial biases by questionnaire. Physicians reported no explicit preference for white versus black patients or differences in perceived cooperativeness. In contrast, IATs revealed implicit preference favoring white Americans (mean IAT score = 0.36, P < .001, one-sample t test) and implicit stereotypes of black Americans as less cooperative with medical procedures (mean IAT score 0.22, P < .001), and less cooperative generally (mean IAT score 0.30, P < .001). As physicians' prowhite implicit bias increased, so did their likelihood of treating white patients and not treating black patients with thrombolysis (P = .009). This study represents the first evidence of unconscious (implicit) race bias among physicians, its dissociation from conscious (explicit) bias, and its predictive validity. Results suggest that physicians' unconscious biases may contribute to racial/ethnic disparities in use of medical procedures such as thrombolysis for myocardial infarction.

  7. The Risk of Hemorrhagic Transformation After Thrombolysis for Acute Ischemic Stroke in Chinese Versus North Americans: A Comparative Study.

    PubMed

    Xu, Xiaomeng; Wang, Deren; Wang, Fang; Norton, Casey; Liu, Xinfeng; Selim, Magdy

    2018-05-16

    There is a widespread belief that Asians are more susceptible to hemorrhagic transformation (HT) after receiving recombinant tissue-type plasminogen activator (rt-PA) for acute ischemic stroke (AIS). However, this has not been examined in clinical practice. This study aims to compare the incidence of symptomatic hemorrhagic transformation (SHT) among thrombolysis-treated AIS patients in China and in the United States. We compared 212 consecutive patients receiving thrombolysis within 4.5 hours of onset ± endovascular therapy from an American (n = 86) and a Chinese Stroke Center (n = 126). SHT was defined using various definitions based on the National Institute for Neurological Disorders and Stroke Recombinant Tissue Plasminogen Activator (NINDS rt-PA) trials, European-Australian Cooperative Acute Stroke Study 2 (ECASS2), and a modified version of Safe Implementation of Thrombolysis in Stroke-Monitoring Study (mSITS-MOST) study criteria. We used Firth logistic regression to adjust for confounding variables and to identify potential predictors. American patients were older, and had higher prevalence of diabetes, hypertension, cardiac disease, and prestroke use of antithrombotics. They also had higher baseline serum glucose, shorter onset-to-treatment time, and fewer endovascular treatments. The rates of SHT were higher in the American cohort compared to the Chinese cohort: 18.6% versus 14.3% based on NINDS definition of SHT; 15.1% versus 12.7% based on ECASS2; and 11.6% versus 7.2% based on mSITS-MOST. However, none of these differences were significant (unadjusted and adjusted P values > .05). Fatal HT was comparable in Americans versus Chinese (8.1% versus 8.7%). Serum glucose emerged as an independent predictor of SHT (P = .024). In our cohorts, the rate of SHT after thrombolysis is equivalent between Chinese and North American stroke patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. Thrombolysis ImPlementation in Stroke (TIPS): evaluating the effectiveness of a strategy to increase the adoption of best evidence practice – protocol for a cluster randomised controlled trial in acute stroke care

    PubMed Central

    2014-01-01

    Background Stroke is a leading cause of death and disability internationally. One of the three effective interventions in the acute phase of stroke care is thrombolytic therapy with tissue plasminogen activator (tPA), if given within 4.5 hours of onset to appropriate cases of ischaemic stroke. Objectives To test the effectiveness of a multi-component multidisciplinary collaborative approach compared to usual care as a strategy for increasing thrombolysis rates for all stroke patients at intervention hospitals, while maintaining accepted benchmarks for low rates of intracranial haemorrhage and high rates of functional outcomes for both groups at three months. Methods and design A cluster randomised controlled trial of 20 hospitals across 3 Australian states with 2 groups: multi- component multidisciplinary collaborative intervention as the experimental group and usual care as the control group. The intervention is based on behavioural theory and analysis of the steps, roles and barriers relating to rapid assessment for thrombolysis eligibility; it involves a comprehensive range of strategies addressing individual-level and system-level change at each site. The primary outcome is the difference in tPA rates between the two groups post-intervention. The secondary outcome is the proportion of tPA treated patients in both groups with good functional outcomes (modified Rankin Score (mRS <2) and the proportion with intracranial haemorrhage (mRS ≥2), compared to international benchmarks. Discussion TIPS will trial a comprehensive, multi-component and multidisciplinary collaborative approach to improving thrombolysis rates at multiple sites. The trial has the potential to identify methods for optimal care which can be implemented for stroke patients during the acute phase. Study findings will include barriers and solutions to effective thrombolysis implementation and trial outcomes will be published whether significant or not. Trial registration Australian New Zealand Clinical Trials Registry: ACTRN12613000939796 PMID:24666591

  9. [Evaluation of therapeutic strategies for myocardial infarction: the ESTIM Midi-Pyrénées survey].

    PubMed

    Charpentier, S; Celse, D; Cambou, J P; Lauque, D; Carrie, D; Galinier, M; Baïxas, C; Ducassé, J L; Puel, J

    2005-11-01

    The aim of the ESTIM Midi-Pyrénées survey was to monitor the management of acute coronary syndrome with ST segment elevation by cardiologists and emergency departments in the Midi-Pyrénées region. Over a period of 2 years between June 2001 and June 2003, 1287 patients presenting with acute coronary syndrome within the first 24 hours were recruited prospectively. The initial management of these patients was undertaken either by a mobile medical team in the pre-hospital phase, or in a hospital emergency department, non-interventional cardiology department or an interventional cardiology department in 51.8%, 28.8%, 9.6% et 9.9% of cases respectively. Depending on these four modes of initial management, the median time for initial management was 1h30, 2h45, 4h30 et 4h respectively. Emergency coronary reperfusion was proposed in 89.6% of cases. Of the patients in whom reperfusion was attempted within the first 12 hours, 33.7% underwent pre-hospital thrombolysis (median delay of 1h48), 35.8% underwent thrombolysis in hospital (median delay 3h), and 30.4% underwent primary angioplasty (median delay 4h40). Thrombolysis was followed by angioplasty in 80% of cases. A combined approach with thrombolysis and angioplasty was applied in 41% of patients. At one month the rate of major cardiac events, death, and/or subsequent myocardial infarction was 12%. Multivariate analysis revealed that the only significant adverse prognostic features were: not offering reperfusion [Odds ratio (OR) 4, confidence interval (CI) 2.3-3.7] and age [OR 3.8, CI 2.3-6.2]. The method of reperfusion did not influence the subsequent outcome in this regional survey. pre-hospital management allows early revascularisation. In our region there was no significant prognostic difference between pre-hospital thrombolysis and primary angioplasty. It shows that the logistic and therapeutic potentials of prehospital care are not being sufficiently exploited.

  10. Spatial and temporal profile of cisplatin delivery by ultrasound-assisted intravesical chemotherapy in a bladder cancer model.

    PubMed

    Sasaki, Noboru; Ishi, Kazuhiro; Kudo, Nobuki; Nakayama, Shouta M M; Nakamura, Kensuke; Morishita, Keitaro; Ohta, Hiroshi; Ishizuka, Mayumi; Takiguchi, Mitsuyoshi

    2017-01-01

    Non-muscle invasive bladder cancer is one of the most common tumors of the urinary tract. Despite the current multimodal therapy, recurrence and progression of disease have been challenging problems. We hereby introduced a new approach, ultrasound-assisted intravesical chemotherapy, intravesical instillation of chemotherapeutic agents and microbubbles followed by ultrasound exposure. We investigated the feasibility of the treatment for non-muscle invasive bladder cancer. In order to evaluate intracellular delivery and cytotoxic effect as a function to the thickness, we performed all experiments using a bladder cancer mimicking 3D culture model. Ultrasound-triggered microbubble cavitation increased both the intracellular platinum concentration and the cytotoxic effect of cisplatin at the thickness of 70 and 122 μm of the culture model. The duration of enhanced cytotoxic effect of cisplatin by ultrasound-triggered microbubble cavitation was approximately 1 hr. Based on the distance and duration of delivery, we further tested the feasibility of repetition of the treatment. Triple treatment increased the effective distance by 1.6-fold. Our results clearly showed spatial and temporal profile of delivery by ultrasound-triggered microbubble cavitation in a tumor-mimicking structure. Furthermore, we demonstrated that the increase in intracellular concentration results in the enhancement of the cytotoxic effect in a structure with the certain thickness. Repetition of ultrasound exposure would be treatment of choice in future clinical application. Our results suggest ultrasound-triggered microbubble cavitation can be repeatable and is promising for the local control of non-muscle invasive bladder cancer.

  11. WE-A-18C-01: Emerging and Innovative Ultrasound Technology in Diagnosis and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emelianov, S; Oraevsky, A; Stafford, R

    The application of new ultrasound-based technologies in medicine has expanded in recent years. One area of rapid growth has been the combination of ultrasound with other methods of image generation and imaging modalities to produce hybrid approaches for diagnostic imaging and noninvasive therapeutic intervention. The presentations associated with this session will provide an overview of two emerging technologies that are currently being developed and implemented to enhance ultrasound-related diagnostic imaging and therapy: the utilization of optically-induced ultrasound imaging (optoacoustic / photoacoustic imaging) and the use of magnetic resonance imaging to guide the use of high-intensity focused ultrasound for therapeutic applications.more » Learning Objectives: Develop a general understanding of the underlying technologies associated with optoacoustic / photoacoustic tomography and MRguided high-intensity focused ultrasound. Develop an understanding of the current methods of these new ultrasound-based technologies in preclinical research and clinical applications.« less

  12. The utility of ultrasound in the assessment of traumatic peripheral nerve lesions: report of 4 cases.

    PubMed

    Zeidenberg, Joshua; Burks, S Shelby; Jose, Jean; Subhawong, Ty K; Levi, Allan D

    2015-09-01

    Ultrasound technology continues to improve with better image resolution and availability. Its use in evaluating peripheral nerve lesions is increasing. The current review focuses on the utility of ultrasound in traumatic injuries. In this report, the authors present 4 illustrative cases in which high-resolution ultrasound dramatically enhanced the anatomical understanding and surgical planning of traumatic peripheral nerve lesions. Cases include a lacerating injury of the sciatic nerve at the popliteal fossa, a femoral nerve injury from a pseudoaneurysm, an ulnar nerve neuroma after attempted repair with a conduit, and, finally, a spinal accessory nerve injury after biopsy of a supraclavicular fossa lesion. Preoperative ultrasound images and intraoperative pictures are presented with a focus on how ultrasound aided with surgical decision making. These cases are set into context with a review of the literature on peripheral nerve ultrasound and a comparison between ultrasound and MRI modalities.

  13. Successful Intra-Arterial Thrombolysis for Acute Ischemic Stroke in the Immediate Postpartum Period: Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendez, Jose C.; Masjuan, J.; Garcia, N.

    2008-01-15

    Stroke in pregnancy and the puerperium is a rare but potentially devastating event. We present the case of a previously healthy woman who underwent a cesarean delivery and experienced a middle cerebral artery thrombosis in the immediate postpartum period that was subsequently lysed with intra-arterial urokinase. The patient made a complete neurologic recovery. To the best of our knowledge, this is the first reported case of successful intra-arterial thrombolysis for ischemic stroke in the postpartum period.

  14. Contrast-enhanced ultrasound (CEUS) in blunt abdominal trauma

    PubMed Central

    Piccolo, Claudia Lucia; Galluzzo, Michele; Ianniello, Stefania; Sessa, Barbara; Trinci, Margherita

    2016-01-01

    Baseline ultrasound is essential in the early assessment of patients with a huge haemoperitoneum undergoing an immediate abdominal surgery; nevertheless, even with a highly experienced operator, it is not sufficient to exclude parenchymal injuries. More recently, a new ultrasound technique using second generation contrast agents, named contrast-enhanced ultrasound (CEUS) has been developed. This technique allows all the vascular phase to be performed in real time, increasing ultrasound capability to detect parenchymal injuries, enhancing some qualitative findings, such as lesion extension, margins and its relationship with capsule and vessels. CEUS has been demonstrated to be almost as sensitive as contrast-enhanced CT in the detection of traumatic injuries in patients with low-energy isolated abdominal trauma, with levels of sensitivity and specificity up to 95%. Several studies demonstrated its ability to detect lesions occurring in the liver, spleen, pancreas and kidneys and also to recognize active bleeding as hyperechoic bands appearing as round or oval spots of variable size. Its role seems to be really relevant in paediatric patients, thus avoiding a routine exposure to ionizing radiation. Nevertheless, CEUS is strongly operator dependent, and it has some limitations, such as the cost of contrast media, lack of panoramicity, the difficulty to explore some deep regions and the poor ability to detect injuries to the urinary tract. On the other hand, it is timesaving, and it has several advantages, such as its portability, the safety of contrast agent, the lack to ionizing radiation exposure and therefore its repeatability, which allows follow-up of those traumas managed conservatively, especially in cases of fertile females and paediatric patients. PMID:26607647

  15. A theranostic nrGO@MSN-ION nanocarrier developed to enhance the combination effect of sonodynamic therapy and ultrasound hyperthermia for treating tumor

    NASA Astrophysics Data System (ADS)

    Chen, Yu-Wei; Liu, Tse-Ying; Chang, Po-Hsueh; Hsu, Po-Hung; Liu, Hao-Li; Lin, Hong-Cheu; Chen, San-Yuan

    2016-06-01

    Sonodynamic therapy (SDT), which induces activation of sonosensitizers in cancer cells through ultrasound irradiation, has emerged as an alternative and promising noninvasive therapeutic approach to kill both superficial and deep parts of tumors. In this study, mesoporous silica (MSN) grown on reduced graphene oxide nanosheet (nrGO) capped with Rose Bengal (RB)-PEG-conjugated iron-oxide nanoparticles (IONs), nrGO@MSN-ION-PEG-RB, was strategically designed to have targeted functionality and therapeutic efficacy under magnetic guiding and focused ultrasound (FUS) irradiation, respectively. The singlet oxygen produced by ultrasound-activated RB and the ultrasound-induced heating effect was enhanced by rGO and IONs, which improved the cytotoxic effect in cancer cells. In an animal experiment, we demonstrated that the combination of sonodynamic/hyperthermia therapy with magnetic guidance using this nanocomposite therapeutic agent can produce remarkable efficacious therapy in tumor growth inhibition. Furthermore, the combination effect induced by FUS irradiation produces significant damage to both superficial and deep parts of the targeted tumor.Sonodynamic therapy (SDT), which induces activation of sonosensitizers in cancer cells through ultrasound irradiation, has emerged as an alternative and promising noninvasive therapeutic approach to kill both superficial and deep parts of tumors. In this study, mesoporous silica (MSN) grown on reduced graphene oxide nanosheet (nrGO) capped with Rose Bengal (RB)-PEG-conjugated iron-oxide nanoparticles (IONs), nrGO@MSN-ION-PEG-RB, was strategically designed to have targeted functionality and therapeutic efficacy under magnetic guiding and focused ultrasound (FUS) irradiation, respectively. The singlet oxygen produced by ultrasound-activated RB and the ultrasound-induced heating effect was enhanced by rGO and IONs, which improved the cytotoxic effect in cancer cells. In an animal experiment, we demonstrated that the combination of sonodynamic/hyperthermia therapy with magnetic guidance using this nanocomposite therapeutic agent can produce remarkable efficacious therapy in tumor growth inhibition. Furthermore, the combination effect induced by FUS irradiation produces significant damage to both superficial and deep parts of the targeted tumor. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07782f

  16. Application of Ultrasound Energy as a New Drug Delivery System

    NASA Astrophysics Data System (ADS)

    Tachibana, Katsuro; Tachibana, Shunro

    1999-05-01

    Ultrasound has been in use for the last three decades as amodality for diagnostic imaging in medicine. Recently, there have beennumerous reports on the application of nonthermal ultrasound energyfor targeting or controlling drug release. This new concept oftherapeutic ultrasound combined with drugs has led to much excitementin various medical fields. Ultrasound energy can enhance the effectsof thrombolytic agents such as urokinase. Therapeutic ultrasoundcatheters are currently being developed for treatment ofcardiovascular diseases. Devices with ultrasound transducers implantedin transdermal drug patches are also being evaluated for possibledelivery of insulin through the skin. Chemical activation of drugs byultrasound energy for treatment of cancers is another new fieldrecently termed “Sonodynamic Therapy”. Various examples of ultrasoundapplication are under investigation which could lead to revolutionarydrug delivery systems in the future.

  17. Focused ultrasound and microbubbles for enhanced extravasation.

    PubMed

    Böhmer, M R; Chlon, C H T; Raju, B I; Chin, C T; Shevchenko, T; Klibanov, A L

    2010-11-20

    The permeability of blood vessels for albumin can be altered by using ultrasound and polymer or lipid-shelled microbubbles. The region in which the microbubbles were destroyed with focused ultrasound was quantified in gel phantoms as a function of pressure, number of cycles and type of microbubble. At 2MPa the destruction took place in a fairly wide area for a lipid-shelled agent, while for polymer-shelled agents at this setting, distinct destruction spots with a radius of only 1mm were obtained. When microbubbles with a thicker shell were used, the pressure above which the bubbles were destroyed shifts to higher values. In vivo both lipid and polymer microbubbles increased the extravasation of the albumin binding dye Evans Blue, especially in muscle leading to about 6-8% of the injected dose to extravasate per gram muscle tissue 30 min after start of the treatment, while no Evans Blue could be detected in muscle in the absence of microbubbles. Variation in the time between ultrasound treatment and Evans Blue injection, demonstrated that the time window for promoting extravasation is at least an hour at the settings used. In MC38 tumors, extravasation already occurred without ultrasound and only a trend towards enhancement with about a factor of 2 could be established with a maximum percentage injected dose per gram of 3%. Ultrasound mediated microbubble destruction especially enhances the extravasation in the highly vascularized outer part of the MC38 tumor and adjacent muscle and would, therefore, be most useful for release of, for instance, anti-angiogenic drugs. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Thermosonication as a potential quality enhancement technique of apple juice.

    PubMed

    Abid, Muhammad; Jabbar, Saqib; Hu, Bing; Hashim, Malik Muhammad; Wu, Tao; Lei, Shicheng; Khan, Muhammad Ammar; Zeng, Xiaoxiong

    2014-05-01

    Enzymatic browning and microbial growth lead to quality losses in apple products. In the present study, fresh apple juice was thermosonicated using ultrasound in-bath (25 kHz, 30 min, 0.06 W cm(-3)) and ultrasound with-probe sonicator (20 kHz, 5 and 10 min, 0.30 W cm(-3)) at 20, 40 and 60°C for inactivation of enzymes (polyphenolase, peroxidase and pectinmethylesterase) and microflora (total plate count, yeast and mold). Additionally, ascorbic acid, total phenolics, flavonoids, flavonols, pH, titratable acidity, (°)Brix and color values influenced by thermosonication were investigated. The highest inactivation of enzymes was obtained in ultrasound with-probe at 60°C for 10 min, and the microbial population was completely inactivated at 60°C. The retention of ascorbic acid, total phenolics, flavonoids and flavonols were significantly higher in ultrasound with-probe than ultrasound in-bath at 60°C. These results indicated the usefulness of thermosonication for apple juice processing at low temperature, for enhanced inactivation of enzymes and microorganisms. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Ultrasound assisted process intensification of uricase and alkaline protease enzyme co-production in Bacillus licheniformis.

    PubMed

    Pawar, Shweta V; Rathod, Virendra K

    2018-07-01

    Low energy ultrasound irradiation was used to enhance co-production of enzymes uricase and alkaline protease using Bacillus licheniformis NRRL 14209. Production of uricase and alkaline protease was evaluated for different ultrasound parameters such as ultrasound power, time of irradiation, duty cycle and growth stage of organisms at which irradiation is carried out. Maximum uricase production of 0.825 U/mL and alkaline protease of 0.646 U/mL have been obtained when fermentation broth was irradiated at 6 h of growth stage with 60 W power for 15 min of duration having 40% of duty cycle. The enzyme yield was found to be enhanced by a factor of 1.9-3.8 and 1.2-2.2 for uricase and alkaline protease respectively. Nevertheless, intracellular uricase was also observed in a fermentation broth after ultrasonic process intensification. The results indicate the effectiveness of low frequency ultrasound in improving enzyme yields with a vision of commercial applicability of the process. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Intensifying radiation induced grafting of 4-vinylpyridine/glycidyl methacrylate mixtures onto poly(ethylene-co-tetrafluoroethylene) films using ultrasound

    NASA Astrophysics Data System (ADS)

    Nasef, Mohamed Mahmoud; Sithambaranathan, Paveswari; Ahmad, Arshad; Abouzari-lotf, Ebrahim

    2017-05-01

    A new ultrasound-aided method was used to enhance grafting of 4-vinylpyridine (4-VP) and glycidyl methacrylate (GMA) monomers mixtures onto electron beam (EB) irradiated poly(ethylene-co-tetrafluoroethylene) (ETFE) film for the first time. The effects of reaction parameters such as absorbed dose, monomer concentration, reaction time on both of degree of grafting (DG) and grafting efficiency (GE) were investigated under sonication and conventional grafting at similar temperatures. Fourier transform infrared (FTIR) and atomic force microscopy (AFM) were used to monitor the impact of the applied ultrasound on composition and surfaces of the grafted films whereas 1H-NMR was used to investigate composition of the grafting residues. The ultrasound-aided grafting of 4-VP/GMA was found to enhance both of DG% and GE remarkably. Moreover, it produced grafted ETFE films having smoother surfaces without homopolymer contamination compared to grafted films obtained from conventional grafting. The results of this study suggest that the use of ultrasound is a promising way for intensifying grafting process and improving its economy.

  1. Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation.

    PubMed

    Liu, Tianzhi; Zhang, Nan; Wang, Zhigang; Wu, Meiying; Chen, Yu; Ma, Ming; Chen, Hangrong; Shi, Jianlin

    2017-09-26

    High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H 2 O 2 , facilitating the continuous O 2 gas generation in a relatively mild manner even if incubated with 10 μM H 2 O 2 , which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H 2 O 2 -enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo. Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.

  2. Influence of extrinsic operational parameters on salt diffusion during ultrasound assisted meat curing.

    PubMed

    Inguglia, Elena S; Zhang, Zhihang; Burgess, Catherine; Kerry, Joseph P; Tiwari, Brijesh K

    2018-02-01

    The present study investigated the effect of geometric parameters of the ultrasound instrument during meat salting in order to enhance salt diffusion and salt distribution in pork meat on a lab scale. The effects of probe size (∅2.5 and 1.3cm) and of different distances between the transducer and the meat sample (0.3, 0.5, and 0.8cm) on NaCl diffusion were investigated. Changes in the moisture content and NaCl gain were used to evaluate salt distribution and diffusion in the samples, parallel and perpendicular to ultrasound propagation direction. Results showed that 0.3cm was the most efficient distance between the probe and the sample to ensure a higher salt diffusion rate. A distance of 0.5cm was however considered as a trade-off distance to ensure salt diffusion and maintenance of meat quality parameters. The enhancement of salt diffusion by ultrasound was observed to decrease with increased horizontal distance from the probe. This study is of valuable importance for meat processing industries willing to apply new technologies on a larger scale and with defined operational standards. The data suggest that the geometric parameters of ultrasound systems can have strong influence on the efficiency of ultrasonic enhancement of NaCl uptake in meat and can be a crucial element in determining salt uptake during meat processing. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    PubMed

    Nemec, Ursula; Nemec, Stefan F; Novotny, Clemens; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2012-06-01

    To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. These patients were scheduled for surgery and underwent preoperative CEUS with pulse-inversion harmonic imaging after intravenous microbubble contrast medium administration. Using histology as a standard of reference, time-intensity curves of benign and malignant nodules were compared by means of peak enhancement and wash-out enhancement relative to the baseline intensity using a mixed model ANOVA. ROC analysis was performed to assess the diagnostic accuracy in the differentiation of benign and malignant nodules on CEUS. The complete CEUS data of 42 patients (31/42 [73.8%] benign and 11/42 [26.2%] malignant nodules) revealed a significant difference (P < 0.001) in enhancement between benign and malignant nodules. Furthermore, based on ROC analysis, CEUS demonstrated sensitivity of 76.9%, specificity of 84.8% and accuracy of 82.6%. Quantitative analysis of CEUS using a microbubble contrast agent allows the differentiation of benign and malignant thyroid nodules and may potentially serve, in addition to grey-scale and Doppler ultrasound, as an adjunctive tool in the assessment of patients with thyroid nodules. • Contrast-enhanced ultrasound (CEUS) helps differentiate between benign and malignant thyroid nodules. • Quantitative CEUS analysis yields sensitivity of 76.9% and specificity of 84.8%. • CEUS may be a potentially useful adjunct in assessing thyroid nodules.

  4. Towards Dynamic Contrast Specific Ultrasound Tomography

    NASA Astrophysics Data System (ADS)

    Demi, Libertario; van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2016-10-01

    We report on the first study demonstrating the ability of a recently-developed, contrast-enhanced, ultrasound imaging method, referred to as cumulative phase delay imaging (CPDI), to image and quantify ultrasound contrast agent (UCA) kinetics. Unlike standard ultrasound tomography, which exploits changes in speed of sound and attenuation, CPDI is based on a marker specific to UCAs, thus enabling dynamic contrast-specific ultrasound tomography (DCS-UST). For breast imaging, DCS-UST will lead to a more practical, faster, and less operator-dependent imaging procedure compared to standard echo-contrast, while preserving accurate imaging of contrast kinetics. Moreover, a linear relation between CPD values and ultrasound second-harmonic intensity was measured (coefficient of determination = 0.87). DCS-UST can find clinical applications as a diagnostic method for breast cancer localization, adding important features to multi-parametric ultrasound tomography of the breast.

  5. Towards Dynamic Contrast Specific Ultrasound Tomography.

    PubMed

    Demi, Libertario; Van Sloun, Ruud J G; Wijkstra, Hessel; Mischi, Massimo

    2016-10-05

    We report on the first study demonstrating the ability of a recently-developed, contrast-enhanced, ultrasound imaging method, referred to as cumulative phase delay imaging (CPDI), to image and quantify ultrasound contrast agent (UCA) kinetics. Unlike standard ultrasound tomography, which exploits changes in speed of sound and attenuation, CPDI is based on a marker specific to UCAs, thus enabling dynamic contrast-specific ultrasound tomography (DCS-UST). For breast imaging, DCS-UST will lead to a more practical, faster, and less operator-dependent imaging procedure compared to standard echo-contrast, while preserving accurate imaging of contrast kinetics. Moreover, a linear relation between CPD values and ultrasound second-harmonic intensity was measured (coefficient of determination = 0.87). DCS-UST can find clinical applications as a diagnostic method for breast cancer localization, adding important features to multi-parametric ultrasound tomography of the breast.

  6. Towards Dynamic Contrast Specific Ultrasound Tomography

    PubMed Central

    Demi, Libertario; Van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2016-01-01

    We report on the first study demonstrating the ability of a recently-developed, contrast-enhanced, ultrasound imaging method, referred to as cumulative phase delay imaging (CPDI), to image and quantify ultrasound contrast agent (UCA) kinetics. Unlike standard ultrasound tomography, which exploits changes in speed of sound and attenuation, CPDI is based on a marker specific to UCAs, thus enabling dynamic contrast-specific ultrasound tomography (DCS-UST). For breast imaging, DCS-UST will lead to a more practical, faster, and less operator-dependent imaging procedure compared to standard echo-contrast, while preserving accurate imaging of contrast kinetics. Moreover, a linear relation between CPD values and ultrasound second-harmonic intensity was measured (coefficient of determination = 0.87). DCS-UST can find clinical applications as a diagnostic method for breast cancer localization, adding important features to multi-parametric ultrasound tomography of the breast. PMID:27703251

  7. Ultrasound and computed tomography of the iliosacral lymphatic centre in dogs with anal sac gland carcinoma.

    PubMed

    Pollard, R E; Fuller, M C; Steffey, M A

    2017-06-01

    In this prospective study, we hypothesized that computed tomography (CT) would identify more normal and abnormal iliosacral lymph nodes (LNs) than abdominal ultrasound in dogs with anal sac gland carcinoma (ASGC). Twelve client-owned dogs with ASGC but without distant metastasis were enrolled. Abdominal ultrasound and contrast-enhanced CT scans of the abdomen were obtained. Iliosacral LNs were counted and assessed for location, laterality and size. Significantly (P < 0.00001) more iliosacral LNs were identified with CT (61) than ultrasound (30), including significantly (P = 0.00012) more medial iliac LNs with CT (33) than ultrasound (19). There was no difference in number of internal iliac LNs identified with CT versus ultrasound. Significantly (P = 0.000061) more sacral LNs were identified with CT (15) than ultrasound (0). Ultrasound identified slightly more (7) abnormal iliosacral LNs than CT (5). Contrast CT was able to identify more normal but not more abnormal LNs than ultrasound. © 2015 John Wiley & Sons Ltd.

  8. Contrast enhanced ultrasound of renal masses. A reappraisal of EFSUMB recommendations and possible emerging applications.

    PubMed

    Sparchez, Zeno; Radu, Pompilia; Sparchez, Mihaela; Crisan, Nicolae; Kacso, Gabriel; Petrut, Bogdan

    2015-06-01

    The main imagistic method for characterization of renal lesions is contrast enhanced computed tomography (CECT). Disadvantages of CECT are a contrast-induced nephropathy in patients with renal impairment, allergic reactions and high costs. Contrast-enhanced ultrasound (CEUS) evaluation of hepatic and non-hepatic lesions is a relatively new, but increasingly utilised, diagnostic method. In 2011 the European Federation of Societies of Ultrasound in Medicine and Biology (EFSUMB) updated the Guidelines and Recommendations on the Clinical Practice of CEUS and included in the recommendation the renal pathology. However, there are several possible new indications that have not been discussed (pyelocaliceal masses and renal vein thrombosis) and several issues that remain controversial such as the differentiation of benign and malignant tumours or the differentiation of lymphoma and metastasis. This study aims to review literature data, as well as reveal the latest findings in the field of renal CEUS.

  9. Polymer Coated Echogenic Lipid Nanoparticles with Dual Release Triggers

    PubMed Central

    Nahire, Rahul; Haldar, Manas K.; Paul, Shirshendu; Mergoum, Anaas; Ambre, Avinash H.; Katti, Kalpana S.; Gange, Kara N.; Srivastava, D. K.; Sarkar, Kausik; Mallik, Sanku

    2013-01-01

    Although lipid nanoparticles are promising drug delivery vehicles, passive release of encapsulated contents at the target site is often slow. Herein, we report contents release from targeted, polymer coated, echogenic lipid nanoparticles in the cell cytoplasm by redox trigger and simultaneously enhanced by diagnostic frequency ultrasound. The lipid nanoparticles were polymerized on the external leaflet using a disulfide cross-linker. In the presence of cytosolic concentrations of glutathione, the lipid nanoparticles released 76% of encapsulated contents. Plasma concentrations of glutathione failed to release the encapsulated contents. Application of 3 MHz ultrasound for 2 minutes simultaneously with the reducing agent enhanced the release to 96%. Folic acid conjugated, doxorubicin loaded nanoparticles showed enhanced uptake and higher cytotoxicity in cancer cells overexpressing the folate receptor (compared to the control). With further developments, these lipid nanoparticles have the potential to be used as multimodal nanocarriers for simultaneous targeted drug delivery and ultrasound imaging. PMID:23394107

  10. The Role of Acoustic Cavitation in Ultrasound-triggered Drug Release from Echogenic Liposomes

    NASA Astrophysics Data System (ADS)

    Kopechek, Jonathan A.

    Cardiovascular disease (CVD) is the leading cause of death in the United States and globally. CVD-related mortality, including coronary heart disease, heart failure, or stroke, generally occurs due to atherosclerosis, a condition in which plaques build up within arterial walls, potentially causing blockage or rupture. Targeted therapies are needed to achieve more effective treatments. Echogenic liposomes (ELIP), which consist of a lipid membrane surrounding an aqueous core, have been developed to encapsulate a therapeutic agent and/or gas bubbles for targeted delivery and ultrasound image enhancement. Under certain conditions ultrasound can cause nonlinear bubble growth and collapse, known as "cavitation." Cavitation activity has been associated with enhanced drug delivery across cellular membranes. However, the mechanisms of ultrasound-mediated drug release from ELIP have not been previously investigated. Thus, the objective of this dissertation is to elucidate the role of acoustic cavitation in ultrasound-mediated drug release from ELIP. To determine the acoustic and physical properties of ELIP, the frequency-dependent attenuation and backscatter coefficients were measured between 3 and 30 MHz. The results were compared to a theoretical model by measuring the ELIP size distribution in order to determine properties of the lipid membrane. It was found that ELIP have a broad size distribution and can provide enhanced ultrasound image contrast across a broad range of clinically-relevant frequencies. Calcein, a hydrophilic fluorescent dye, and papaverine, a lipophilic vasodilator, were separately encapsulated in ELIP and exposed to color Doppler ultrasound pulses from a clinical diagnostic ultrasound scanner in a flow system. Spectrophotometric techniques (fluorescence and absorbance measurements) were used to detect calcein or papaverine release. As a positive control, Triton X-100 (a non-ionic detergent) was added to ELIP samples not exposed to ultrasound in order to release encapsulated agents completely. Also, sham samples without Triton X-100 or ultrasound exposure were used as negative controls. Color Doppler ultrasound did not release encapsulated calcein or papaverine from ELIP even though there was a complete loss of echogenicity. In subsequent experiments, calcein and rosiglitazone, a hydrophobic anti-diabetic drug, were separately encapsulated in ELIP and exposed to pulsed Doppler ultrasound in a flow system while monitoring cavitation. Samples were exposed to ultrasound pressures above and below cavitation thresholds. In addition, Triton X-100 was used for positive control samples and sham samples were also tested without ultrasound exposure. Adding Triton X-100 resulted in complete release of encapsulated calcein or rosiglitzone. However, Doppler ultrasound exposure did not induce calcein or rosiglitazone release from ELIP in the flow system even when there was persistent cavitation activity and a loss of echogenicity. The results of this dissertation indicate that cavitation of encapsulated bubbles in ELIP solutions is not sufficient to induce drug release. It is possible that ultrasoundmediated thermal processes may have a stronger effect on ELIP permeability than cavitation activity. Perhaps ultrasound-triggered drug release will be possible by improving the ELIP formulation or encapsulating a different gas instead of air. However, cavitation is not a reliable indicator of ultrasound-mediated drug release with the ELIP formulations used in this dissertation.

  11. Structure formation and properties of a copper-aluminum joint produced by ultrasound-assisted explosive welding

    NASA Astrophysics Data System (ADS)

    Kuz'min, E. V.; Peev, A. P.; Kuz'min, S. V.; Lysak, V. I.

    2017-08-01

    The effect of ultrasound-assisted explosive welding on the structure formation and the properties of copper-aluminum joints is studied. Ultrasound-assisted explosive welding improves the quality of formed copper-aluminum joints, i.e., enhances their strength and significantly reduces the amount of fused metal over the entire weldability range. It is shown that ultrasound-assisted explosive welding can noticeably extend the weldability range of the copper-aluminum pair to obtain equal-in-strength joints with minimum structural heterogeneity in the wide welding range.

  12. Transvaginal Ultrasound for the Diagnosis of Abnormal Uterine Bleeding.

    PubMed

    Wheeler, Karen C; Goldstein, Steven R

    2017-03-01

    Transvaginal ultrasound is the first-line imaging test for the evaluation of abnormal uterine bleeding in both premenopausal and postmenopausal women. Transvaginal ultrasound can be used to diagnose structural causes of abnormal bleeding such as polyps, adenomyosis, leiomyomas, hyperplasia, and malignancy, and can also be beneficial in making the diagnosis of ovulatory dysfunction. Traditional 2-dimensional imaging is often enhanced by the addition of 3-dimension imaging with coronal reconstruction and saline infusion sonohysterography. In this article we discuss specific ultrasound findings and technical considerations useful in the diagnosis of abnormal uterine bleeding.

  13. Synthetic thrombus model for in vitro studies of laser thrombolysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermes, R.E.; Trajkovska, K.

    1998-07-01

    Laser thrombolysis is the controlled ablation of a thrombus (blood clot) blockage in a living arterial system. Theoretical modeling of the interaction of laser light with thrombi relies on the ability to perform in vitro experiments with well characterized surrogate materials. A synthetic thrombus formulation may offer more accurate results when compared to in vivo clinical experiments. The authors describe the development of new surrogate materials based on formulations incorporating chick egg, guar gum, modified food starch, and a laser light absorbing dye. The sound speed and physical consistency of the materials were very close to porcine (arterial) and humanmore » (venous) thrombi. Photographic and videotape recordings of pulsed dye laser ablation experiments under various experimental conditions were used to evaluate the new material as compared to in vitro tests with human (venous) thrombus. The characteristics of ablation and mass removal were similar to that of real thrombi, and therefore provide a more realistic model for in vitro laser thrombolysis when compared to gelatin.« less

  14. Digestive and urologic hemorrhage after intravenous thrombolysis for acute ischemic stroke: Data from a Chinese stroke center.

    PubMed

    Chang, Hong; Wang, Xiaojuan; Yang, Xin; Song, Haiqing; Qiao, Yuchen; Liu, Jia

    2017-02-01

    Objective Intravenous thrombolysis with recombinant tissue plasminogen activator (rt-PA) is considered the most effective treatment method for AIS; however, it is associated with a risk of hemorrhage. We analyzed the risk factors for digestive and urologic hemorrhage during rt-PA therapy. Methods We retrospectively analyzed patients with AIS who underwent intravenous thrombolysis with rt-PA during a 5-year period in a Chinese stroke center. Data on the demographics, medical history, laboratory test results, and clinical outcomes were collected. Results 338 patients with AIS were eligible and included. Logistic regression multivariate analysis showed that gastric catheter was significantly correlated with digestive hemorrhage, while age and urinary catheter were significantly correlated with urologic hemorrhage. Most hemorrhagic events were associated with catheterization after 1 to 24 hours of rt-PA therapy. Conclusions In summary, gastric and urinary catheters were correlated with digestive and urologic hemorrhage in patients with AIS undergoing rt-PA therapy. Well-designed controlled studies with large samples are required to confirm our findings.

  15. Recanalization Therapies in Acute Ischemic Stroke: Pharmacological Agents, Devices, and Combinations

    PubMed Central

    Sharma, Vijay K.; Teoh, Hock Luen; Wong, Lily Y. H.; Su, Jie; Ong, Benjamin K. C.; Chan, Bernard P. L.

    2010-01-01

    The primary aim of thrombolysis in acute ischemic stroke is recanalization of an occluded intracranial artery. Recanalization is an important predictor of stroke outcome as timely restoration of regional cerebral perfusion helps salvage threatened ischemic tissue. At present, intravenously administered tissue plasminogen activator (IV-TPA) remains the only FDA-approved therapeutic agent for the treatment of ischemic stroke within 3 hours of symptom onset. Recent studies have demonstrated safety as well as efficacy of IV-TPA even in an extended therapeutic window. However, the short therapeutic window, low rates of recanalization, and only modest benefits with IV-TPA have prompted a quest for alternative approaches to restore blood flow in an occluded artery in acute ischemic stroke. Although intra-arterial delivery of the thrombolytic agent seems effective, various logistic constraints limit its routine use and as yet no lytic agent have not received full regulatory approval for intra-arterial therapy. Mechanical devices and approaches can achieve higher rates of recanalization but their safety and efficacy still need to be established in larger clinical trials. The field of acute revascularization is rapidly evolving, and various combinations of pharmacologic agents, mechanical devices, and novel microbubble/ultrasound technologies are being tested in multiple clinical trials. PMID:20798838

  16. Blotting from PhastGel to Membranes by Ultrasound.

    PubMed

    Kost, Joseph; Azagury, Aharon

    2015-01-01

    Ultrasound based approach for enhanced protein blotting is proposed. Three minutes of ultrasound exposure (1 MHz, 2.5 W/cm(2)) was sufficient for a clear transfer of proteins from a polyacrylamide gel (PhastGel) to nitrocellulose or Nylon 66 Biotrans membrane. The proteins evaluated were prestained sodium dodecyl sulfate-polyacrylamide standards (18,500-106,000 Da) and 14C-labeled Rainbow protein molecular weight markers (14,300-200,000 Da).

  17. Blotting from PhastGel to membranes by ultrasound.

    PubMed

    Kost, Joseph

    2009-01-01

    Ultrasound-based approach for enhanced protein blotting is proposed. Three minutes of ultrasound exposure (1 MHz, 2.5 W/cm(2)) was sufficient for a clear transfer of proteins from a polyacrylamide gel (PhastGel) to nitrocellulose or Nylon 66 Biotrans membrane. The proteins evaluated were prestained sodium dodecyl sulfate-polyacrylamide standards (18,500-106,000 Da) and (14)C-labeled Rainbow protein molecular weight markers (14,300-200,000 Da).

  18. Augmentation of the In Vivo Elastic Properties Measurement System to Include Bulk Properties

    DTIC Science & Technology

    2015-09-30

    stranded animals. OBJECTIVES The primary objective of this project is to develop an ultrasound -based system for non-invasive determination of in...wherein ultrasound is used to both generate and observe low frequency vibration in soft tissues. While current methods have been successfully applied...pattern. A second ultrasonic transducer monitors the tissue displacement along the ultrasound beam axis, and supports an enhanced embodiment of an

  19. Systematic Review of Treatment for Trapped Thrombus in Patent Foramen Ovale.

    PubMed

    Seo, Won-Woo; Kim, Sung Eun; Park, Myung-Soo; Lee, Jun-Hee; Park, Dae-Gyun; Han, Kyoo-Rok; Oh, Dong-Jin

    2017-09-01

    Trapped thrombus in patent foramen ovale (PFO) is a rare complication of pulmonary embolism that may lead to tragic clinical events. The aim of this study was to identify the optimal treatment for different clinical situations in patients with trapped thrombus in a PFO by conducting a literature review. A PubMed database search was conducted from 1991 through 2015, and 194 patients (185 articles) with trapped thrombus in a PFO were identified. Patient characteristics, paradoxical embolic events, and factors affecting 60-day mortality were analyzed retrospectively. Among all patients, 112 (57.7%) were treated with surgery, 28 with thrombolysis, and 54 with anticoagulation alone. Dyspnea (79.4%), chest pain (33.0%), and syncope (17.5%) were the most common presenting symptoms. Pretreatment embolism was found in 37.6% of cases, and stroke (24.7%) was the most common event. Surgery was associated with fewer post-treatment embolic events than were other treatment options (p=0.044). In the multivariate analysis, initial shock or arrest, and thrombolysis were independent predictors of 60-day mortality. Thrombolysis was related with higher 60-day mortality compared with surgery in patients who had no initial shock or arrest. This systematic review showed that surgery was associated with a lower overall incidence of post-treatment embolic events and a lower 60-day mortality in patients with trapped thrombus in a PFO. In patients without initial shock or arrest, thrombolysis was related with a higher 60-day mortality compared with surgery.

  20. Collaborative Interventions Reduce Time-to-Thrombolysis for Acute Ischemic Stroke in a Public Safety Net Hospital.

    PubMed

    Threlkeld, Zachary D; Kozak, Benjamin; McCoy, David; Cole, Sara; Martin, Christine; Singh, Vineeta

    2017-07-01

    Shorter time-to-thrombolysis in acute ischemic stroke (AIS) is associated with improved functional outcome and reduced morbidity. We evaluate the effect of several interventions to reduce time-to-thrombolysis at an urban, public safety net hospital. All patients treated with tissue plasminogen activator for AIS at our institution between 2008 and 2015 were included in a retrospective analysis of door-to-needle (DTN) time and associated factors. Between 2011 and 2014, we implemented 11 distinct interventions to reduce DTN time. Here, we assess the relative impact of each intervention on DTN time. The median DTN time pre- and postintervention decreased from 87 (interquartile range: 68-109) minutes to 49 (interquartile range: 39-63) minutes. The reduction was comprised primarily of a decrease in median time from computed tomography scan order to interpretation. The goal DTN time of 60 minutes or less was achieved in 9% (95% confidence interval: 5%-22%) of cases preintervention, compared with 70% (58%-81%) postintervention. Interventions with the greatest impact on DTN time included the implementation of a stroke group paging system, dedicated emergency department stroke pharmacists, and the development of a stroke code supply box. Multidisciplinary, collaborative interventions are associated with a significant and substantial reduction in time-to-thrombolysis. Such targeted interventions are efficient and achievable in resource-limited settings, where they are most needed. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Budget impact analysis of thrombolysis for stroke in Spain: a discrete event simulation model.

    PubMed

    Mar, Javier; Arrospide, Arantzazu; Comas, Mercè

    2010-01-01

    Thrombolysis within the first 3 hours after the onset of symptoms of a stroke has been shown to be a cost-effective treatment because treated patients are 30% more likely than nontreated patients to have no residual disability. The objective of this study was to calculate by means of a discrete event simulation model the budget impact of thrombolysis in Spain. The budget impact analysis was based on stroke incidence rates and the estimation of the prevalence of stroke-related disability in Spain and its translation to hospital and social costs. A discrete event simulation model was constructed to represent the flow of patients with stroke in Spain. If 10% of patients with stroke from 2000 to 2015 would receive thrombolytic treatment, the prevalence of dependent patients in 2015 would decrease from 149,953 to 145,922. For the first 6 years, the cost of intervention would surpass the savings. Nevertheless, the number of cases in which patient dependency was avoided would steadily increase, and after 2006 the cost savings would be greater, with a widening difference between the cost of intervention and the cost of nonintervention, until 2015. The impact of thrombolysis on society's health and social budget indicates a net benefit after 6 years, and the improvement in health grows continuously. The validation of the model demonstrates the adequacy of the discrete event simulation approach in representing the epidemiology of stroke to calculate the budget impact.

  2. [Implementation of a regional system for the emergency care of acute ischemic stroke: Initial results].

    PubMed

    Soares-Oliveira, Miguel; Araújo, Fernando

    2014-06-01

    Implementing integrated systems for emergency care of patients with acute ischemic stroke helps reduce morbidity and mortality. We describe the process of organizing and implementing a regional system to cover around 3.7 million people and its main initial results. We performed a descriptive analysis of the implementation process and a retrospective analysis of the following parameters: number of patients prenotified by the pre-hospital system; number of times thrombolysis was performed; door-to-needle time; and functional assessment three months after stroke. The implementation process started in November 2005 and ended in December 2009, and included 11 health centers. There were 3574 prenotifications from the prehospital system. Thrombolysis was performed in 1142 patients. The percentage of patients receiving thrombolysis rose during the study period, with a maximum of 16%. Median door-to-needle time was 62 min in 2009. Functional recovery three months after stroke was total or near total in 50% of patients. The regional system implemented for emergency care of patients with acute ischemic stroke has led to health gains, with progressive improvements in patients' access to thrombolysis, and to greater equity in the health care system, thus helping to reduce mortality from cerebrovascular disease in Portugal. Our results, which are comparable with those of international studies, support the strategy adopted for implementation of this system. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  3. Telestroke in Northern Alberta: a two year experience with remote hospitals.

    PubMed

    Khan, Khurshid; Shuaib, Ashfaq; Whittaker, Tammy; Saqqur, Maher; Jeerakathil, Thomas; Butcher, Ken; Crumley, Patrick

    2010-11-01

    Thrombolysis in acute ischemic stroke is usually performed in comprehensive stroke centres. Lack of stroke expertise in remote small hospitals may preclude thrombolysis. Telemedicine allows such management opportunities in distant hospitals. We report our experience in managing acute stroke over a two-year time period with telestroke. The University of Alberta Hospital acted as the 'hub' and seven remote hospitals as 'spoke'. The neurologist at the 'hub' provided stroke expertise to the local physician using either a two-way video link or telephone. Cranial CT scans were transmitted to 'hub'. Education sessions were held before the initiation of the program. Of 210 patients 44 (21%) received thrombolysis at the 'spoke' sites. In 34/44 (77%) two-way video link was available while in 10/44 (23%) telephone was used. Five (11.4%) patients experienced intracranial hemorrhage after thrombolysis, 2 (4.5%) were symptomatic. Favorable (mRS=0-1) outcome at three months was 16/40 (40%) and mortality was 9/40 (22.5%). Four patients were lost to follow-up. There was no significant three months outcome difference between two-way video link and telephone consultation (P = 0.689). Over two years the number of acute stroke transfers decreased from 144 to 15 at one of the 'spoke' sites, a 92.5% decline. It is possible to successfully treat patients with acute ischemic stroke at remote sites through videoconferencing or telephone consultation. Telestroke can also lead to a significant reduction in the number of patients requiring transfer to a tertiary care centre.

  4. Ultrasonic Enhancement of Antibiotic Action on Escherichia coli Biofilms: an In Vivo Model

    PubMed Central

    Rediske, Andrea M.; Roeder, Beverly L.; Brown, Maren K.; Nelson, Jared L.; Robison, Rachel L.; Draper, David O.; Schaalje, G. Bruce; Robison, Richard A.; Pitt, William G.

    1999-01-01

    Biofilm infections are a common complication of prosthetic devices in humans. Previous in vitro research has determined that low-frequency ultrasound combined with aminoglycoside antibiotics is an effective method of killing biofilms. We report the development of an in vivo model to determine if ultrasound enhances antibiotic action. Two 24-h-old Escherichia coli (ATCC 10798) biofilms grown on polyethylene disks were implanted subcutaneously on the backs of New Zealand White female rabbits, one on each side of the spine. Low-frequency (28.48-kHz) and low-power-density (100- and 300-mW/cm2) continuous ultrasound treatment was applied for 24 h with and without systemic administration of gentamicin. The disks were then removed, and the number of viable bacteria on each disk was determined. At the low ultrasonic power used in this study, exposure to ultrasound only (no gentamicin) caused no significant difference in bacterial viability. In the presence of antibiotic, there was a significant reduction due to 300-mW/cm2 ultrasound (P = 0.0485) but no significant reduction due to 100-mW/cm2 ultrasound. Tissue damage to the skin was noted at the 300-mW/cm2 treatment level. Further development of this technique has promise in treatment of clinical implant infections. PMID:10223938

  5. Ultrasonic enhancement of antibiotic action on Escherichia coli biofilms: an in vivo model.

    PubMed

    Rediske, A M; Roeder, B L; Brown, M K; Nelson, J L; Robison, R L; Draper, D O; Schaalje, G B; Robison, R A; Pitt, W G

    1999-05-01

    Biofilm infections are a common complication of prosthetic devices in humans. Previous in vitro research has determined that low-frequency ultrasound combined with aminoglycoside antibiotics is an effective method of killing biofilms. We report the development of an in vivo model to determine if ultrasound enhances antibiotic action. Two 24-h-old Escherichia coli (ATCC 10798) biofilms grown on polyethylene disks were implanted subcutaneously on the backs of New Zealand White female rabbits, one on each side of the spine. Low-frequency (28.48-kHz) and low-power-density (100- and 300-mW/cm2) continuous ultrasound treatment was applied for 24 h with and without systemic administration of gentamicin. The disks were then removed, and the number of viable bacteria on each disk was determined. At the low ultrasonic power used in this study, exposure to ultrasound only (no gentamicin) caused no significant difference in bacterial viability. In the presence of antibiotic, there was a significant reduction due to 300-mW/cm2 ultrasound (P = 0.0485) but no significant reduction due to 100-mW/cm2 ultrasound. Tissue damage to the skin was noted at the 300-mW/cm2 treatment level. Further development of this technique has promise in treatment of clinical implant infections.

  6. [Value of contrast-enhanced ultrasound (CEUS) in the differential diagnosis between benign and malignant renal neoplasms].

    PubMed

    Zhang, Sheng; Wang, Xiao-qing; Xin, Xiao-jie; Xu, Yong

    2013-05-01

    To investigate the value of contrast enhanced ultrasound (CEUS) imaging in the differential diagnosis between benign and malignant renal neoplasms. Two hundred and forty-five cases of renal space-occupying lesions confirmed by biopsy or surgical pathology were included in this study. The CEUS features of the renal space-occupying lesions, i.e., the enhancement degree, homogeneity of enhancement, washing-in and washing-out time and enhancement pattern, were retrospectively analyzed. There were 210 cases of malignant renal tumors and 35 cases of benign lesions. The CEUS modes of the malignant renal tumors included "quick in and quick out" 82 cases, "quick in and slow out" 64 cases, "slow in and quick out" 18 cases and "slow in and slow out" 46 cases; good enhancement 150 cases (71.4%) and inhomogeneous enhancement 180 cases (85.7%).Both the contrast agent filling defect area and solid component enhancement of solid-cystic tumors were important features of malignant renal tumors. In the 35 cases of benign lesions,the CEUS modes included "quick in and quick out" 4 cases, "quick in and slow out" 8 cases, "slow in and quick out" 10 cases and "slow in and slow out" 13 cases. Most of the benign tumors showed low enhancement 51.4% (18/35) and inhomogeneous enhancement 54.3% (19/35). There were significant differences between the malignant and benign renal neoplasms in CEUS mode, degree of enhancement and homogeneity of enhancement (P < 0.05), and in time of increasing, peak time, peak intensity and peak intensity ratio (P < 0.05). The accuracy rates of contrast-enhanced ultrasound for diagnosis of benign and malignant tumors were 77.1% and 83.8%, respectively, while the two-dimensional ultrasound diagnosis of benign and malignant tumors were 68.6% and 76.7%, respectively, with a significant difference (P < 0.05). CEUS may provide more information to improve the diagnostic accuracy for renal neoplasms, and may play important role in differential diagnosis between benign and malignant renal lesions.

  7. Combination of bubble liposomes and high-intensity focused ultrasound (HIFU) enhanced antitumor effect by tumor ablation.

    PubMed

    Hamano, Nobuhito; Negishi, Yoichi; Takatori, Kyohei; Endo-Takahashi, Yoko; Suzuki, Ryo; Maruyama, Kazuo; Niidome, Takuro; Aramaki, Yukihiko

    2014-01-01

    Ultrasound (US) is used in the clinical setting not only for diagnosis but also for therapy. As a therapeutic US technique, high-intensity focused ultrasound (HIFU) can be applied to treat cancer in a clinical setting. Microbubbles increased temperature and improved the low therapeutic efficiency under HIFU; however, microbubbles have room for improvement in size, stability, and targeting ability. To solve these issues, we reported that "Bubble liposomes" (BLs) containing the US imaging gas (perfluoropropane gas) liposomes were suitable for ultrasound imaging and gene delivery. In this study, we examined whether BLs and HIFU could enhance the ablation area of the tumor and the antitumor effect. First, we histologically analyzed the tumor after BLs and HIFU. The ablation area of the treatment of BLs and HIFU was broader than that of HIFU alone. Next, we monitored the temperature of the tumor, and examined the antitumor effect. The temperature increase with BLs and HIFU treatment was faster and higher than that with HIFU alone. Moreover, treatment with BLs and HIFU enhanced the antitumor effect, which was better than with HIFU alone. Thus, the combination of BLs and HIFU could be efficacious for cancer therapy.

  8. Laser Sources for Generation of Ultrasound

    NASA Technical Reports Server (NTRS)

    Wagner, James W.

    1996-01-01

    Two laser systems have been built and used to demonstrate enhancements beyond current technology used for laser-based generation and detection of ultrasound. The first system consisted of ten Nd:YAG laser cavities coupled electronically and optically to permit sequential bursts of up to ten laser pulses directed either at a single point or configured into a phased array of sources. Significant enhancements in overall signal-to-noise ratio for laser ultrasound incorporating this new source system was demonstrated, using it first as a source of narrowband ultrasound and secondly as a phased array source producing large enhanced signal displacements. A second laser system was implemented using ultra fast optical pulses from a Ti:Sapphire laser to study a new method for making laser generated ultrasonic measurements of thin films with thicknesses on the order of hundreds of angstroms. Work by prior investigators showed that such measurements could be made based upon fluctuations in the reflectivity of thin films when they are stressed by an arriving elastic pulse. Research performed using equipment purchased under this program showed that a pulsed interferometric system could be used as well as a piezoreflective detection system to measure pulse arrivals even in thin films with very low piezoreflective coefficients.

  9. Acoustic fingerprints of photoacoustic contrast agents for molecular imaging

    NASA Astrophysics Data System (ADS)

    McDonald, Michael A.; Jankovic, Ladislav; Shahzad, Khalid; Burcher, Michael; Li, King C. P.

    2007-02-01

    Protein nanospheres capable of frequency controlled oscillation in response to laser stimulation are presented as contrast agents for photoacoustic imaging. Incident laser energy absorbed by dye-labeled protein nanospheres causes thermoelastically generated sound production. Plotted A-line graphs reveal a distinctive morphology and greater than 2 orders of magnitude increase in signal amplitude subsequent to converting labeled proteins into nanospheres. Evidence of nonlinearity and enhancement of ultrasound backscatter indicate a potential use in contrast-enhanced harmonic imaging. Photoacoustic and ultrasound imaging of protein nanospheres in phantom vessels show enhanced contrast at low concentration and clear delineation of the phantom vessel wall.

  10. Use of eddy current mixes to solve a weld examination application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, R.C.; LaBoissonniere, A.

    1995-12-31

    The augmentation of typical nondestructive (i.e., ultrasound) weld inspection techniques by the use of eddy current tools may significantly enhance the quality and reliability of weld inspections. One recent example is the development of an eddy current technique for use in the examination of BWR core shroud welds, where multi-frequency mixes are used to eliminate signals coming from the weld material so that the examination of the heat affected zone is enhanced. An analysis tool most commonly associated with ultrasound examinations, the C-Scan based on gated information, may be implemented with eddy current data to enhance analysis.

  11. Ultrasound-enhanced delivery of antibiotics and anti-inflammatory drugs into the eye.

    PubMed

    Nabili, Marjan; Patel, Hetal; Mahesh, Sankaranarayana P; Liu, Ji; Geist, Craig; Zderic, Vesna

    2013-04-01

    Delivery of sufficient amounts of therapeutic drugs into the eye is often a challenging task. In this study, ultrasound application (frequencies of 400 KHz to 1 MHz, intensities of 0.3-1.0 W/cm(2) and exposure duration of 5 min) was investigated to overcome the barrier properties of cornea, which is a typical route for topical administration of ophthalmic drugs. Permeability of ophthalmic drugs, tobramycin and dexamethasone and sodium fluorescein, a drug-mimicking compound, was studied in ultrasound- and sham-treated rabbit corneas in vitro using a standard diffusion cell setup. Light microscopy observations were used to determine ultrasound-induced structural changes in the cornea. For tobramycin, an increase in permeability for ultrasound- and sham-treated corneas was not statistically significant. Increase of 46%-126% and 32%-109% in corneal permeability was observed for sodium fluorescein and dexamethasone, respectively, with statistical significance (p < 0.05) achieved at all treatment parameter combinations (compared with sham treatments) except for 1-MHz ultrasound applications for dexamethasone experiments. This permeability increase was highest at 400 kHz and appeared to be higher at higher intensities applied. Histologic analysis showed structural changes that were limited to epithelial layers of cornea. In summary, ultrasound application provided enhancement of drug delivery, increasing the permeability of the cornea for the anti-inflammatory ocular drug dexamethasone. Future investigations are needed to determine the effectiveness and safety of this application in in vivo long-term survival studies. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Prehospital Advanced Diagnostics and Treatment of Acute Stroke: Protocol for a Controlled Intervention Study.

    PubMed

    Bache, Kristi G; Hov, Maren Ranhoff; Larsen, Karianne; Solyga, Volker Moræus; Lund, Christian G

    2018-02-28

    Acute ischemic stroke (AIS) is a medical emergency. The outcome is closely linked to the time elapsing from symptom onset to treatment, and seemingly small delays can mean the difference between full recovery and physical and cognitive dysfunction. Recanalization to allow blood to reenter the affected area is most efficient immediately after symptoms occur, and intravenous thrombolysis must be initiated no later than 4.5 hours after the symptom onset. A liable diagnosis is mandatory to administer the appropriate treatment. Prehospital diagnosis and, in cases where contraindications are ruled out, prehospital initiation of intravenous thrombolysis have been shown to significantly decrease the time from alarm to the treatment. The objective of this paper is to investigate the effectiveness of prehospital thrombolysis as measured by (1) time spent from symptom onset to treatment and (2) the number of patients treated within 4.5 hours. In addition, we want to conduct explorative studies. These will include (1) the use of biomarkers for diagnostic and prognostic use where we will collect blood samples from various time points, including the hyperacute phase and (2) the study of magnetic resonance imaging (MRI) images at day 1 to determine the infarct volume and if the time to thrombolysis has an influence on this. This is a prospective controlled intervention study. The intervention will involve a computed tomography (CT) and thrombolysis in a physician-manned ambulance called a mobile stroke unit (MSU). The control will be the conventional pathway where the patient is transported to the hospital for CT, and thrombolysis as per current procedure. Patient inclusion has started and a total of 37 patients are enrolled (control and intervention combined). The estimated time to completed inclusion is 36 months, starting from May 2017. The results of this study will be analyzed and published at the end of the trial. This trial aims to document the feasibility of saving time for all stroke patients by providing prehospital diagnostics and treatment, as well as transport to appropriate level of care, in a safe environment provided by anesthesiologists trained in prehospital critical care. ClinicalTrials.gov NCT03158259; https://clinicaltrials.gov/show/NCT03158259 (Archived by WebCite at http://www.webcitation.org/6wxNEUMUD). ©Kristi G Bache, Maren Ranhoff Hov, Karianne Larsen, Volker Moræus Solyga, Christian G Lund. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 28.02.2018.

  13. Association of early National Institutes of Health Stroke Scale improvement with vessel recanalization and functional outcome after intravenous thrombolysis in ischemic stroke.

    PubMed

    Kharitonova, Tatiana; Mikulik, Robert; Roine, Risto O; Soinne, Lauri; Ahmed, Niaz; Wahlgren, Nils

    2011-06-01

    Early neurological improvement (ENI) after thrombolytic therapy of acute stroke has been linked with recanalization and favorable outcome, although its definition shows considerable variation. We tested the ability of ENI, as defined in previous publications, to predict vessel recanalization and 3-month functional outcome after intravenous thrombolysis recorded in an extensive patient cohort in the Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register (SITS-ISTR). Of 21,534 patients registered between December 2002 and December 2008, 798 patients (3.7%) had CT- or MR angiography-documented baseline vessel occlusion and also angiography data at 22 to 36 hours post-treatment. ENI definitions assessed at 2 hours and 24 hours post-treatment were (1) National Institutes of Health Stroke Scale (NIHSS) score improvement ≥4 points from baseline; (2) NIHSS 0, 1, or improvement ≥8; (3) NIHSS ≤3 or improvement ≥10; (4) improvement by 20%; (5) 40% from baseline; or (6) NIHSS score 0 to 1. Receiver operating curve analysis and multiple logistic regression were performed to evaluate the association of ENI with vessel recanalization and favorable functional outcome (modified Rankin Scale score 0 to 2 at 3 months). ENI at 2 hours had fair accuracy to diagnose recanalization as derived from receiver operating curve analysis. Definitions of improvement based on percent of NIHSS score change from baseline demonstrate better accuracy to diagnose recanalization at 2 hours and 24 hours than the definitions based on NIHSS cutoffs (the best performance at 2 hours was area under the curve 0.633, sensitivity 58%, specificity 69%, positive predictive value 68%, and negative predictive value 59% for 20% improvement; and area under the curve 0.692, sensitivity 69%, specificity 70%, positive predictive value 70%, and negative predictive value 62% for 40% improvement at 24 hours). ENI-predicted functional outcome with OR 2.8 to 6.0 independently from recanalization in the angiography cohort (n=695) and with OR of 6.9 to 9.7 in the whole cohort (n=18 181). Early 20% neurological improvement at 2 hours was the best predictor of 3-month functional outcome and recanalization after thrombolysis, although fairly accurate, and may serve as a surrogate marker of recanalization if only imaging evaluation of vessel status is not available. If recanalization status is required after intravenous thrombolysis, vascular imaging is recommended despite ENI.

  14. Contrast-enhanced ultrasound and computed tomography findings of granulomatosis with polyangiitis presenting with multiple intrarenal microaneurysms: A case report.

    PubMed

    Kim, Youe Ree; Lee, Young Hwan; Lee, Jong-Ho; Yoon, Kwon-Ha

    Granulomatosis with polyangiitis (GPA) is a systemic disorder that affects small- and medium- sized vessels in many organs. Although the kidneys are the second most commonly involved organ in patients with GPA, its manifestation as multiple intrarenal aneurysms is rare. We report an unusual manifestation of GPA with multiple intrarenal microaneurysms, as demonstrated by contrast-enhanced ultrasound and computed tomography. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Comparison of Oral Contrast-Enhanced Transabdominal Ultrasound Imaging With Transverse Contrast-Enhanced Computed Tomography in Preoperative Tumor Staging of Advanced Gastric Carcinoma.

    PubMed

    He, Xuemei; Sun, Jing; Huang, Xiaoling; Zeng, Chun; Ge, Yinggang; Zhang, Jun; Wu, Jingxian

    2017-12-01

    This study assessed the diagnostic performance of transabdominal oral contrast-enhanced ultrasound (US) imaging for preoperative tumor staging of advanced gastric carcinoma by comparing it with transverse contrast-enhanced computed tomography (CT). This retrospective study included 42 patients with advanced gastric cancer who underwent laparoscopy, radical surgery, or palliative surgery because of serious complications and had a body mass index of less than 25 kg/m 2 . A cereal-based oral contrast agent was used for transabdominal oral contrast-enhanced US. Retrospective analyses were conducted using preoperative tumor staging data acquired by either transabdominal oral contrast-enhanced US or transverse contrast-enhanced CT. Both contrast-enhanced US and contrast-enhanced CT examinations were reviewed by 2 experienced radiologists independently for preoperative tumor staging according to the seventh edition of the TNM classification. The accuracy, sensitivity, and specificity were calculated by comparing the results of contrast-enhanced US and contrast-enhanced CT with pathologic findings. The overall accuracies of the imaging modalities were compared by the McNemar test. No significant difference was noted in the overall accuracy of transabdominal oral contrast-enhanced US (86% [36 of 42]) and transverse contrast-enhanced CT (83% [35 of 42] P > .999). For stage T2 to T4 gastric cancer, the accuracies of transabdominal oral contrast-enhanced US were 88%, 86%, and 98%, respectively, and those of transverse contrast-enhanced CT were 93%, 83%, and 90%. The overall accuracy of transabdominal oral contrast-enhanced US was comparable with that of transverse contrast-enhanced CT for preoperative tumor staging of advanced gastric cancer. © 2017 by the American Institute of Ultrasound in Medicine.

  16. Acoustic Response of Microbubbles Derived from Phase-Change Nanodroplet

    NASA Astrophysics Data System (ADS)

    Kawabata, Ken-ichi; Asami, Rei; Azuma, Takashi; Umemura, Shin-ichiro

    2010-07-01

    An in vitro feasibility test for a novel ultrasound therapy using a type of superheated perfluorocarbon droplet, phase-change nanodroplet (PCND), was performed in gel phantoms with the goal of high selectivity and low invasiveness. Measurements of broadband signal emission revealed that a triggering ultrasound pulse (peak negative pressure of 2.4 MPa) reduces the pressure threshold for cavitation induced by a subsequent ultrasound exposure at an order of magnitude from 2.4 to 0.2 MPa. The maximum allowed interval between the two ultrasound exposures for inducing cavitation with 100- and 1,000-cycle triggering ultrasound was about 100 and 500 ms, respectively. The echo signal increases induced by the triggering ultrasound with 100- and 1000-cycles were enhanced and suppressed by the subsequent ultrasound exposure, respectively. This different behavior seemed to be due to the presence of enlarged free bubbles, which should be avoided for the localization of therapeutic effects.

  17. A contrast enhancement method for improving the segmentation of breast lesions on ultrasonography.

    PubMed

    Flores, Wilfrido Gómez; Pereira, Wagner Coelho de Albuquerque

    2017-01-01

    This paper presents an adaptive contrast enhancement method based on sigmoidal mapping function (SACE) used for improving the computerized segmentation of breast lesions on ultrasound. First, from the original ultrasound image an intensity variation map is obtained, which is used to generate local sigmoidal mapping functions related to distinct contextual regions. Then, a bilinear interpolation scheme is used to transform every original pixel to a new gray level value. Also, four contrast enhancement techniques widely used in breast ultrasound enhancement are implemented: histogram equalization (HEQ), contrast limited adaptive histogram equalization (CLAHE), fuzzy enhancement (FEN), and sigmoid based enhancement (SEN). In addition, these contrast enhancement techniques are considered in a computerized lesion segmentation scheme based on watershed transformation. The performance comparison among techniques is assessed in terms of both the quality of contrast enhancement and the segmentation accuracy. The former is quantified by the measure, where the greater the value, the better the contrast enhancement, whereas the latter is calculated by the Jaccard index, which should tend towards unity to indicate adequate segmentation. The experiments consider a data set with 500 breast ultrasound images. The results show that SACE outperforms its counterparts, where the median values for the measure are: SACE: 139.4, SEN: 68.2, HEQ: 64.1, CLAHE: 62.8, and FEN: 7.9. Considering the segmentation performance results, the SACE method presents the largest accuracy, where the median values for the Jaccard index are: SACE: 0.81, FEN: 0.80, CLAHE: 0.79, HEQ: 77, and SEN: 0.63. The SACE method performs well due to the combination of three elements: (1) the intensity variation map reduces intensity variations that could distort the real response of the mapping function, (2) the sigmoidal mapping function enhances the gray level range where the transition between lesion and background is found, and (3) the adaptive enhancing scheme for coping with local contrasts. Hence, the SACE approach is appropriate for enhancing contrast before computerized lesion segmentation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Enhancement in Diffusion of Electrolyte through Membrane Using Ultrasonic Dialysis Equipment with Plane Membrane

    NASA Astrophysics Data System (ADS)

    Li, Hui; Ohdaira, Etsuzo; Ide, Masao

    1995-05-01

    Application of ultrasound to accelerate the dialysis separation of electrolytes through a membrane was studied with ultrasonic dialysis equipment. The experiments were conducted with cellophane membrane and KCl solution, CH3COONa solution, and a mixture of KCl and saponin solutions. It was found that the diffusion velocity of electrolyte through a membrane with ultrasonic irradiation is faster than that without ultrasonic irradiation, and it increases with acoustic pressure. It has become clear that the reasons for enhancement caused by ultrasound are increase in liquid particle velocity and diffusion coefficient due to ultrasonic vibration. It was confirmed that the permeability of the membrane was not degraded by ultrasound in the ranges of acoustic pressure and irradiation time in this study.

  19. Drug Release from Phase-Changeable Nanodroplets Triggered by Low-Intensity Focused Ultrasound

    PubMed Central

    Cao, Yang; Chen, Yuli; Yu, Tao; Guo, Yuan; Liu, Fengqiu; Yao, Yuanzhi; Li, Pan; Wang, Dong; Wang, Zhigang; Chen, Yu; Ran, Haitao

    2018-01-01

    Background: As one of the most effective triggers with high tissue-penetrating capability and non-invasive feature, ultrasound shows great potential for controlling the drug release and enhancing the chemotherapeutic efficacy. In this study, we report, for the first time, construction of a phase-changeable drug-delivery nanosystem with programmable low-intensity focused ultrasound (LIFU) that could trigger drug-release and significantly enhance anticancer drug delivery. Methods: Liquid-gas phase-changeable perfluorocarbon (perfluoropentane) and an anticancer drug (doxorubicin) were simultaneously encapsulated in two kinds of nanodroplets. By triggering LIFU, the nanodroplets could be converted into microbubbles locally in tumor tissues for acoustic imaging and the loaded anticancer drug (doxorubicin) was released after the microbubble collapse. Based on the acoustic property of shell materials, such as shell stiffness, two types of nanodroplets (lipid-based nanodroplets and PLGA-based nanodroplets) were activated by different acoustic pressure levels. Ultrasound irradiation duration and power of LIFU were tested and selected to monitor and control the drug release from nanodroplets. Various ultrasound energies were introduced to induce the phase transition and microbubble collapse of nanodroplets in vitro (3 W/3 min for lipid nanodroplets; 8 W/3 min for PLGA nanodroplets). Results: We detected three steps in the drug-releasing profiles exhibiting the programmable patterns. Importantly, the intratumoral accumulation and distribution of the drug with LIFU exposure were significantly enhanced, and tumor proliferation was substantially inhibited. Co-delivery of two drug-loaded nanodroplets could overcome the physical barriers of tumor tissues during chemotherapy. Conclusion: Our study provides a new strategy for the efficient ultrasound-triggered chemotherapy by nanocarriers with programmable LIFU capable of achieving the on-demand drug release. PMID:29507623

  20. Ultrasound-Enhanced Delivery of Antibiotics and Anti-Inflammatory Drugs into the Eye

    PubMed Central

    Nabili, Marjan; Patel, Hetal; Mahesh, Sankaranarayana P.; Liu, Ji; Geist, Craig; Zderic, Vesna

    2013-01-01

    Delivery of sufficient amounts of therapeutic drugs into the eye is often a challenging task. In this study, ultrasound application (frequencies of 400 KHz to 1 MHz, intensities of 0.3–1.0 W/cm2 and exposure duration of 5 min) was investigated to overcome the barrier properties of cornea, which is a typical route for topical administration of ophthalmic drugs. Permeability of ophthalmic drugs, tobramycin and dexamethasone and sodium fluorescein, a drug-mimicking compound, was studied in ultrasound- and sham-treated rabbit corneas in vitro using a standard diffusion cell setup. Light microscopy observations were used to determine ultrasound-induced structural changes in the cornea. For tobramycin, an increase in permeability for ultrasound- and sham-treated corneas was not statistically significant. Increase of 46%–126% and 32%–109% in corneal permeability was observed for sodium fluorescein and dexamethasone, respectively, with statistical significance (p < 0.05) achieved at all treatment parameter combinations (compared with sham treatments) except for 1-MHz ultrasound applications for dexamethasone experiments. This permeability increase was highest at 400 kHz and appeared to be higher at higher intensities applied. Histologic analysis showed structural changes that were limited to epithelial layers of cornea. In summary, ultrasound application provided enhancement of drug delivery, increasing the permeability of the cornea for the anti-inflammatory ocular drug dexamethasone. Future investigations are needed to determine the effectiveness and safety of this application in in vivo long-term survival studies. (E-mail: mnabili@gwu.edu) PMID:23415283

  1. Catheter-Directed Thrombolysis of Inferior Vena Cava Thrombosis in a 13-Day-Old Neonate and Review of Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Jawad U.; Takemoto, Clifford M.; Casella, James F.

    Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.

  2. Application of imaging fusion combining contrast-enhanced ultrasound and magnetic resonance imaging in detection of hepatic cellular carcinomas undetectable by conventional ultrasound.

    PubMed

    Dong, Yi; Wang, Wen-Ping; Mao, Feng; Ji, Zheng-Biao; Huang, Bei-Jian

    2016-04-01

    The aim of this study is to explore the value of volume navigation image fusion-assisted contrast-enhanced ultrasound (CEUS) in detection for radiofrequency ablation guidance of hepatocellular carcinomas (HCCs), which were undetectable on conventional ultrasound. From May 2012 to May 2014, 41 patients with 49 HCCs were included in this study. All lesions were detected by dynamic magnetic resonance imaging (MRI) and planned for radiofrequency ablation but were undetectable on conventional ultrasound. After a bolus injection of 2.4 ml SonoVue® (Bracco, Italy), LOGIQ E9 ultrasound system with volume navigation system (version R1.0.5, GE Healthcare, Milwaukee, WI, USA) was used to fuse CEUS and MRI images. The fusion time, fusion success rate, lesion enhancement pattern, and detection rate were analyzed. Image fusions were conducted successfully in 49 HCCs, the technical success rate was 100%. The average fusion time was (9.2 ± 2.1) min (6-12 min). The mean diameter of HCCs was 25.2 ± 5.3 mm (mean ± SD), and mean depth was 41.8 ± 17.2 mm. The detection rate of HCCs using CEUS/MRI imaging fusion (95.9%, 47/49) was significantly higher than CEUS (42.9%, 21/49) (P < 0.05). For small HCCs (diameter, 1-2 cm), the detection rate using imaging fusion (96.9%, 32/33) was also significantly higher than CEUS (18.2%, 6/33) (P < 0.01). All HCCs displayed a rapid wash-in pattern in the arterial phase of CEUS. Imaging fusion combining CEUS and MRI is a promising technique to improve the detection, precise localization, and accurate diagnosis of undetectable HCCs on conventional ultrasound, especially small and atypical HCCs. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  3. Breast cancer screening and problem solving using mammography, ultrasound, and magnetic resonance imaging.

    PubMed

    Hooley, Regina J; Andrejeva, Liva; Scoutt, Leslie M

    2011-03-01

    Although mammography is the mainstay of early breast cancer detection, it has known limitations, particularly in women with dense breasts. As a result, additional imaging modalities, including ultrasound and contrast-enhanced magnetic resonance imaging, are also being used to supplement mammography in the early detection of occult breast cancer. This article reviews the indications and efficacy of mammography, ultrasound, and magnetic resonance imaging as both screening and diagnostic tools.

  4. Diagnostic Imaging of the Hepatobiliary System: An Update.

    PubMed

    Marolf, Angela J

    2017-05-01

    Recent advances in diagnostic imaging of the hepatobiliary system include MRI, computed tomography (CT), contrast-enhanced ultrasound, and ultrasound elastography. With the advent of multislice CT scanners, sedated examinations in veterinary patients are feasible, increasing the utility of this imaging modality. CT and MRI provide additional information for dogs and cats with hepatobiliary diseases due to lack of superimposition of structures, operator dependence, and through intravenous contrast administration. Advanced ultrasound methods can offer complementary information to standard ultrasound imaging. These newer imaging modalities assist clinicians by aiding diagnosis, prognostication, and surgical planning. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Multifunctional microbubbles and nanobubbles for photoacoustic and ultrasound imaging

    PubMed Central

    Kim, Chulhong; Qin, Ruogu; Xu, Jeff S.; Wang, Lihong V.; Xu, Ronald

    2010-01-01

    We develop a novel dual-modal contrast agent—encapsulated-ink poly(lactic-co-glycolic acid) (PLGA) microbubbles and nanobubbles—for photoacoustic and ultrasound imaging. Soft gelatin phantoms with embedded tumor simulators of encapsulated-ink PLGA microbubbles and nanobubbles in various concentrations are clearly shown in both photoacoustic and ultrasound images. In addition, using photoacoustic imaging, we successfully image the samples positioned below 1.8-cm-thick chicken breast tissues. Potentially, simultaneous photoacoustic and ultrasound imaging enhanced by encapsulated-dye PLGA microbubbles or nanobubbles can be a valuable tool for intraoperative assessment of tumor boundaries and therapeutic margins. PMID:20210423

  6. The effect of ultrasound irradiation on the convective heat transfer rate during immersion cooling of a stationary sphere.

    PubMed

    Kiani, Hossein; Sun, Da-Wen; Zhang, Zhihang

    2012-11-01

    It has been proven that ultrasound irradiation can enhance the rate of heat transfer processes. The objective of this work was to study the heat transfer phenomenon, mainly the heat exchange at the surface, as affected by ultrasound irradiation around a stationary copper sphere (k=386W m(-1)K(-1), C(p)=384J kg(-1)K(-1), ρ=8660kg m(-3)) during cooling. The sphere (0.01m in diameter) was immersed in an ethylene glycol-water mixture (-10°C) in an ultrasonic cooling system that included a refrigerated circulator, a flow meter, an ultrasound generator and an ultrasonic bath. The temperature of the sphere was recorded using a data logger equipped with a T-type thermocouple in the center of the sphere. The temperature of the cooling medium was also monitored by four thermocouples situated at different places in the bath. The sphere was located at different positions (0.02, 0.04 and 0.06m) above the transducer surface of the bath calculated considering the center of the sphere as the center of the reference system and was exposed to different intensities of ultrasound (0, 120, 190, 450, 890, 1800, 2800, 3400 and 4100W m(-2)) during cooling. The frequency of the ultrasound was 25kHz. It was demonstrated that ultrasound irradiation can increase the rate of heat transfer significantly, resulting in considerably shorter cooling times. Higher intensities caused higher cooling rates, and Nu values were increased from about 23-27 to 25-108 depending on the intensity of ultrasound and the position of the sphere. However, high intensities of ultrasound led to the generation of heat at the surface of the sphere, thus limiting the lowest final temperature achieved. An analytical solution was developed considering the heat generation and was fitted to the experimental data with R(2) values in the range of 0.910-0.998. Visual observations revealed that both cavitation and acoustic streaming were important for heat transfer phenomenon. Cavitation clouds at the surface of the sphere were the main cause of heating effect. The results showed that closer distances to the transducer surface showed higher cooling rates. On the other hand, despite having a bigger distance from the transducer, when the sphere was located close to the gas-liquid interface the enhancement factor of heat transfer was higher. Ultrasound irradiation showed promising effect for the enhancement of convective heat transfer rate during immersion cooling. More investigations are required to demonstrate the behavior of ultrasound assisted heat transfer and resolve the proper way of the application of ultrasound to assist the cooling and/or freezing processes. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Ultrasound mediated nanoparticle drug delivery

    NASA Astrophysics Data System (ADS)

    Mullin, Lee B.

    Ultrasound is not only a powerful diagnostic tool, but also a promising therapeutic technology that can be used to improve localized drug delivery. Microbubble contrast agents are micron sized encapsulated gas filled bubbles that are administered intravenously. Originally developed to enhance ultrasound images, microbubbles are highly echogenic due to the gas core that provides a detectable impedance difference from the surrounding medium. The core also allows for controlled response of the microbubbles to ultrasound pulses. Microbubbles can be pushed using acoustic radiation force and ruptured using high pressures. Destruction of microbubbles can increase permeability at the cellular and vascular level, which can be advantageous for drug delivery. Advances in drug delivery methods have been seen with the introduction of nanoparticles, nanometer sized objects often carrying a drug payload. In chemotherapy, nanoparticles can deliver drugs to tumors while limiting systemic exposure due to abnormalities in tumor vasculature such large gaps between endothelial cells that allow nanoparticles to enter into the interstitial space; this is referred to as the enhanced permeability and retention (EPR) effect. However, this effect may be overestimated in many tumors. Additionally, only a small percentage of the injected dose accumulates in the tumor, which most the nanoparticles accumulating in the liver and spleen. It is hypothesized that combining the acoustic activity of an ultrasound contrast agent with the high payload and extravasation ability of a nanoparticle, localized delivery to the tumor with reduced systemic toxicity can be achieved. This method can be accomplished by either loading nanoparticles onto the shell of the microbubble or through a coadministration method of both nanoparticles and microbubbles. The work presented in this dissertation utilizes novel and commercial nanoparticle formulations, combined with microbubbles and a variety of ultrasound systems. Ultrasound parameters are optimized to achieve maximum cell internalization of molecules and increased nanoparticle delivery to a cell layer on a coverslip. In-vivo studies demonstrate the possibility of using a lower dose of paclitaxel to slow tumor growth rates, increase doxorubicin concentration in tumor tissue, and enhance tumor delivery of fluorescent molecules through treatments that combine nanoparticles with ultrasound and microbubbles.

  8. Exploitation of sub-micron cavitation nuclei to enhance ultrasound-mediated transdermal transport and penetration of vaccines.

    PubMed

    Bhatnagar, Sunali; Kwan, James J; Shah, Apurva R; Coussios, Constantin-C; Carlisle, Robert C

    2016-09-28

    Inertial cavitation mediated by ultrasound has been previously shown to enable skin permeabilisation for transdermal drug and vaccine delivery, by sequentially applying the ultrasound then the therapeutic in liquid form on the skin surface. Using a novel hydrogel dosage form, we demonstrate that the use of sub-micron gas-stabilising polymeric nanoparticles (nanocups) to sustain and promote cavitation activity during simultaneous application of both drug and vaccine results in a significant enhancement of both the dose and penetration of a model vaccine, Ovalbumin (OVA), to depths of 500μm into porcine skin. The nanocups themselves exceeded the penetration depth of the vaccine (up to 700μm) due to their small size and capacity to 'self-propel'. In vivo murine studies indicated that nanocup-assisted ultrasound transdermal vaccination achieved significantly (p<0.05) higher delivery doses without visible skin damage compared to the use of a chemical penetration enhancer. Transdermal OVA doses of up to 1μg were achieved in a single 90-second treatment, which was sufficient to trigger an antigen-specific immune response. Furthermore, ultrasound-assisted vaccine delivery in the presence of nanocups demonstrated substantially higher specific anti-OVA IgG antibody levels compared to other transdermal methods. Further optimisation can lead to a viable, safe and non-invasive delivery platform for vaccines with potential use in a primary care setting or personalized self-vaccination at home. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Assessment and classification of fistula-in-ano in patients with Crohn's disease by hydrogen peroxide enhanced transanal ultrasound.

    PubMed

    Sloots, C E; Felt-Bersma, R J; Poen, A C; Cuesta, M A; Meuwissen, S G

    2001-09-01

    Crohn's disease is well known for its perianal complications, among which fistulas-in-ano are the most common abnormalities. Fistulas-in-ano in Crohn's disease tend to be complex and have a high recurrence rate. Therefore the role of surgery is generally more conservative. Hydrogen peroxide enhanced transanal ultrasound has proven superior to physical examination, fistulography, computed tomography, and conventional ultrasound in demonstrating the fistula tract. This study examined the fistula tracks in patients with Crohn's disease. Forty-one patients with Crohn's disease and fistula-in-ano were investigated using physical examination, sondage of the fistula, proctoscopy and transanal ultrasound. Hydrogen peroxide was infused via a small catheter into the fistula. The main track and the ramification of the fistula were classified according to the anatomical Parks' classification. Only 9 (22%) patients had a single inter- or transsphincteric fistula. In 5 (12%) patients a single supra- or extrasphincteric fistula (high fistula) was found, in 14 (34%) more than one fistula track (ramified), and in 13 (32%) an anovaginal fistula. Thus 78% of patients had a surgically difficult to treat fistula. In the ramified fistula the main track follows the Parks' classification, but ramifications can have a bizarre pattern which is not in agreement with this classification. Optimal documentation by means of hydrogen peroxide enhanced transanal ultrasound is therefore mandatory before surgery or before other therapies such as anti-tumor necrosis factor treatment.

  10. Therapeutic-Ultrasound-Triggered Shape Memory of a Melamine-Enhanced Poly(vinyl alcohol) Physical Hydrogel.

    PubMed

    Li, Guo; Yan, Qiang; Xia, Hesheng; Zhao, Yue

    2015-06-10

    Therapeutic-ultrasound-triggered shape memory was demonstrated for the first time with a melamine-enhanced poly(vinyl alcohol) (PVA) physical hydrogel. The addition of a small amount of melamine (up to 1.5 wt %) in PVA results in a strong hydrogel due to the multiple H-bonding between the two constituents. A temporary shape of the hydrogel can be obtained by deformation of the hydrogel (∼65 wt % water) at room temperature, followed by fixation of the deformation by freezing/thawing the hydrogel under strain, which induces crystallization of PVA. We show that the ultrasound delivered by a commercially available device designed for the patient's pain relief could trigger the shape recovery process as a result of ultrasound-induced local heating in the hydrogel that melts the crystallized PVA cross-linking. This hydrogel is thus interesting for potential applications because it combines many desirable properties, being mechanically strong, biocompatible, and self-healable and displaying the shape memory capability triggered by a physiological stimulus.

  11. Correction of Non-Linear Propagation Artifact in Contrast-Enhanced Ultrasound Imaging of Carotid Arteries: Methods and in Vitro Evaluation.

    PubMed

    Yildiz, Yesna O; Eckersley, Robert J; Senior, Roxy; Lim, Adrian K P; Cosgrove, David; Tang, Meng-Xing

    2015-07-01

    Non-linear propagation of ultrasound creates artifacts in contrast-enhanced ultrasound images that significantly affect both qualitative and quantitative assessments of tissue perfusion. This article describes the development and evaluation of a new algorithm to correct for this artifact. The correction is a post-processing method that estimates and removes non-linear artifact in the contrast-specific image using the simultaneously acquired B-mode image data. The method is evaluated on carotid artery flow phantoms with large and small vessels containing microbubbles of various concentrations at different acoustic pressures. The algorithm significantly reduces non-linear artifacts while maintaining the contrast signal from bubbles to increase the contrast-to-tissue ratio by up to 11 dB. Contrast signal from a small vessel 600 μm in diameter buried in tissue artifacts before correction was recovered after the correction. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. [Contrast-enhanced ultrasound in animal models].

    PubMed

    Paprottka, P M; Zengel, P; Ingrisch, M; Cyran, C C; Eichhorn, M; Reiser, M F; Nikolaou, K; Clevert, D-A

    2011-06-01

    In the past the detection of tumor perfusion was achieved solely via invasive procedures, such as intravital microscopy or with the help of costly modalities, such as multidetector computed tomography (MDCT), magnetic resonance tomography (MRT) or the combined use of positron emission tomography and computed tomography (PET/CT). Ultrasound offers the non-invasive display of organs without usage of ionizing radiation and it is widely available. However, colour-coded ultrasound and power Doppler do not allow the detection of tumor microcirculation. The introduction of contrast-enhanced ultrasound (CEUS) as well as new high-frequency ultrasound probes made it possible to detect and quantify tumor microcirculation with high resolution. CEUS has been used clinically on human beings for more than 10 years. During the last years different tumor models in experimental animals were used for the establishment of this new technique, e.g. in rats, hamsters and mice. CEUS allows the detection of functional parameters, such as the angiogenetic metabolic status of tissue pretreatment and posttreatment. Further research is required to solve the problems of absolute quantification of these perfusion parameters to allow the comparison of CEUS with other modalities (e.g. MRT and CT).

  13. A review on lipase-catalyzed reactions in ultrasound-assisted systems.

    PubMed

    Lerin, Lindomar A; Loss, Raquel A; Remonatto, Daniela; Zenevicz, Mara Cristina; Balen, Manuela; Netto, Vendelino Oenning; Ninow, Jorge L; Trentin, Cláudia M; Oliveira, J Vladimir; de Oliveira, Débora

    2014-12-01

    The named "green chemistry" has been receiving increasing prominence due to its environmentally friendly characteristics. The use of enzymes as catalysts in processes of synthesis to replace the traditional use of chemical catalysts present as main advantage the fact of following the principles of the green chemistry. However, processes of enzymatic nature generally provide lower yields when compared to the conventional chemical processes. Therefore, in the last years, the ultrasound has been extensively used in enzymatic processes, such as the production of esters with desirable characteristics for the pharmaceutical, cosmetics, and food industry, for the hydrolysis and glycerolysis of vegetable oils, production of biodiesel, etc. Several works found in the open literature suggest that the energy released by the ultrasound during the cavitation phenomena can be used to enhance mass transfer (substrate/enzyme), hence increasing the rate of products formation, and also contributing to enhance the enzyme catalytic activity. Furthermore, the ultrasound is considered a "green" technology due to its high efficiency, low instrumental requirement and significant reduction of the processing time in comparison to other techniques. The main goal of this review was to summarize studies available to date regarding the application of ultrasound in enzyme-catalyzed esterification, hydrolysis, glycerolysis and transesterification reactions.

  14. Healing Response of a Structural Hamstring Injury: Perfusion Imaging 8-Week Follow-Up.

    PubMed

    Kellermann, Marion; Lutter, Christoph; Hotfiel, Thilo

    2018-06-18

    Hamstring injuries are frequently observed in various sports disciplines both in elite and recreational sport. To quantify intramuscular tissue perfusion via contrast-enhanced ultrasound in the acute phase and during the healing of a structural muscle injury confirmed by high-resolution magnetic resonance imaging. Case study. Laboratory environment. A 32-year-old wakeboarder (height = 176 cm, body weight = 76 kg, and body mass index = 24.5 kg/m 2 ) with an acute indirect muscle injury of the semimembranosus muscle. Average values of quantifiable contrast-enhanced ultrasound, represented as peak enhancement and wash-in area under the curve, as well as conventional ultrasound, 1.5T magnetic resonance imaging were assessed at 48-hour, 3-week, and 8-week postinjury. Average values of the quantitative perfusion analysis at 48-hour and 8-week postinjury revealed an approximate 5-fold increase in peak enhancement, and the wash-in area under the curve increased more than 3-fold in the center of the lesion. Magnetic resonance imaging, performed 48 hours after the injury to gather reference data as gold standard, revealed a grade III structural muscle tear. The authors are able to demonstrate significant changes in intramuscular tissue perfusion in the center of the structural lesion as well as in the adjacent tissue. Quantifiable contrast-enhanced ultrasound seems to be able to gather relevant data for the assessment and monitoring of muscle injuries and could be established as a valuable tool for further studies focusing on healing processes or therapeutic interventions.

  15. Effects of Prehospital Thrombolysis in Stroke Patients With Prestroke Dependency.

    PubMed

    Nolte, Christian H; Ebinger, Martin; Scheitz, Jan F; Kunz, Alexander; Erdur, Hebun; Geisler, Frederik; Braemswig, Tim-Bastian; Rozanski, Michal; Weber, Joachim E; Wendt, Matthias; Zieschang, Katja; Fiebach, Jochen B; Villringer, Kersten; Grittner, Ulrike; Kaczmarek, Sabina; Endres, Matthias; Audebert, Heinrich J

    2018-03-01

    Data on effects of intravenous thrombolysis on outcome of patients with ischemic stroke who are dependent on assistance in activities of daily living prestroke are scarce. Recent registry based analyses in activities of daily -independent patients suggest that earlier start of intravenous thrombolysis in the prehospital setting leads to better outcomes when compared with the treatment start in hospital. We evaluated whether these observations can be corroborated in patients with prestroke dependency. This observational, retrospective analysis included all patients with acute ischemic stroke depending on assistance before stroke who received intravenous thrombolysis either on the Stroke Emergency Mobile (STEMO) or through conventional in-hospital care (CC) in a tertiary stroke center (Charité, Campus Benjamin Franklin, Berlin) during routine care. Prespecified outcomes were modified Rankin Scale scores of 0 to 3 and survival at 3 months, as well as symptomatic intracranial hemorrhage. Outcomes were adjusted in multivariable logistic regression. Between February 2011 and March 2015, 122 of 427 patients (28%) treated on STEMO and 142 of 505 patients (28%) treated via CC needed assistance before stroke. Median onset-to-treatment times were 97 (interquartile range, 69-159; STEMO) and 135 (interquartile range, 98-184; CC; P <0.001) minutes. After 3 months, modified Rankin Scale scores of 0 to 3 was observed in 48 STEMO patients (39%) versus 35 CC patients (25%; P =0.01) and 86 (70%, STEMO) versus 85 (60%, CC) patients were alive ( P =0.07). After adjustment, STEMO care was favorable with respect to modified Rankin Scale scores of 0 to 3 (odds ratio, 1.99; 95% confidence interval, 1.02-3.87; P =0.042) with a nonsignificant result for survival (odds ratio, 1.73; 95% confidence interval, 0.95-3.16; P =0.07). Symptomatic intracranial hemorrhage occurred in 5 STEMO versus 12 CC patients (4.2% versus 8.5%; P =0.167). The results of this study suggest that earlier, prehospital (as compared with in-hospital) start of intravenous thrombolysis in acute ischemic stroke may translate into better clinical outcome in patients with prestroke dependency. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02358772. © 2018 American Heart Association, Inc.

  16. Long-Term Survival After Intravenous Thrombolysis for Ischemic Stroke: A Propensity Score-Matched Cohort With up to 10-Year Follow-Up.

    PubMed

    Muruet, Walter; Rudd, Anthony; Wolfe, Charles D A; Douiri, Abdel

    2018-03-01

    Intravenous thrombolysis with alteplase is one of the few approved treatments for acute ischemic stroke; nevertheless, little is known about its long-term effects on survival and recovery because clinical trials follow-up times are limited. Patients registered between January 2005 and December 2015, to the population-based South London Stroke Register of first-ever strokes. Propensity score was used to match thrombolyzed and control cases to a 1:2 ratio by demographical and clinical covariates. The primary outcome was survival up to 10 years using Kaplan-Meier estimates, Cox proportional hazards, and restricted mean survival time. Secondary outcomes included stroke recurrence and functional status (Barthel Index and Frenchay Activities Index scores) at 5 years. From 2052 ischemic strokes, 246 treated patients were matched to 492 controls. Median follow-up time 5.45 years (interquartile range, 4.56). Survival was higher in the treatment group (median, 5.72 years) compared with control group (4.98 years, stratified log-rank test <0.001). The number needed to treat to prevent 1 death at 5 years was 12 and 20 at 10 years. After Cox regression analysis, thrombolysis reduced risk of mortality by 37% (hazard ratio, 0.63; 95% confidence interval [CI], 0.48-0.82) at 10 years; however, after introducing a multiplicative interaction term into the model, mortality risk reduction was 42% (hazard ratio, 0.58; 95% CI, 0.40-0.82) at 10 years for those arriving within 3 hours to the hospital. On average, in a 10-year period, treated patients lived 1 year longer than controls. At 5 years, thrombolysis was associated with independence (Barthel Index≥90; odds ratio, 3.76; 95% CI, 1.22-13.34) and increased odds of a higher Frenchay Activities Index (proportional odds ratio, 2.37; 95% CI, 1.16-4.91). There was no difference in stroke recurrence. Thrombolysis with intravenous alteplase is associated with improved long-term survival and functional status after ischemic stroke. © 2018 The Authors.

  17. Leukoaraiosis, cerebral hemorrhage and outcome after IV thrombolysis for acute ischemic stroke: A meta-analysis (v1)

    PubMed Central

    Charidimou, Andreas; Pasi, Marco; Fiorelli, Marco; Shams, Sara; von Kummer, Rüdiger; Pantoni, Leonardo; Rost, Natalia

    2016-01-01

    Background-and-Purpose We performed a meta-analysis to assess whether leukoaraiosis on brain CT scans of acute ischemic stroke patients treated with intravenous (IV) thrombolysis is associated with an increased risk of symptomatic intracerebral hemorrhage (sICH) and/or poor functional outcome at 3–6 months post-stroke. Methods We searched PubMed and pooled relevant data in meta-analyses using random effects models. Using odds ratios (OR), we quantified the strength of association between the presence and severity of leukoaraiosis and post-thrombolysis sICH or 3–6 month modified Rankin Score (mRS) >2. Results Eleven eligible studies (n=7194) were pooled in meta-analysis. The risk of sICH was higher in patients with leukoaraiosis (OR: 1.55; 95%CI: 1.17–2.06, p=0.002) and severe leukoaraiosis (OR: 2.53; 95%CI: 1.92–3.34, p<0.0001), compared to patients without leukoaraiosis. Leukoaraiosis was an independent predictor of sICH in six included studies (n=4976, adjusted-OR: 1.75, 95%CI: 1.35–2.27; p<0.0001). OR for leukoaraiosis and poor 3–6 month outcome was 2.02 (95%CI: 1.54–2.65, p<0.0001), with significant statistical heterogeneity (I2:75.7%, p=0.002). In adjusted analysed, leukoaraiosis was an independent predictor of poor outcome (n=3688, adjusted-OR: 1.61, 95%CI: 1.44–1.79; p<0.0001). In post-hoc analyses, including only leukoaraiosis patients in RCTs (IST-3, NINDS, ECASS-1-2; n=2234), tPA vs. control was associated with higher sICH risk (OR: 5.50; 95%CI: 2.49–12.13), but lower poor outcome risk (OR: 0.75; 95%CI: 0.60–0.95). Conclusions Leukoaraiosis might increase post-IV thrombolysis sICH risk and poor outcome post-stroke. Despite increased sICH risk, IV tPA treatment has net clinical benefit in patients with leukoaraiosis. Given the risk of bias/confounding, these results should be considered hypothesis-generating and do not justify withholding IV thrombolysis. PMID:27491738

  18. The Thrombolytic Effect of Diagnostic Ultrasound-Induced Microbubble Cavitation in Acute Carotid Thromboembolism.

    PubMed

    Porter, Thomas R; Xie, Feng; Lof, John; Powers, Jeffry; Vignon, Francois; Shi, William; White, Matthew

    2017-08-01

    Acute ischemic stroke is often due to thromboembolism forming over ruptured atherosclerotic plaque in the carotid artery (CA). The presence of intraluminal CA thrombus is associated with a high risk of thromboembolic cerebral ischemic events. The cavitation induced by diagnostic ultrasound high mechanical index (MI) impulses applied locally during a commercially available intravenous microbubble infusion has dissolved intravascular thrombi, especially when using longer pulse durations. The beneficial effects of this in acute carotid thromboembolism is not known. An oversized balloon injury was created in the distal extracranial common CA of 38 porcine carotid arteries. After this, a 70% to 80% stenosis was created in the mid common CA proximal to the injury site using partial balloon inflation. Acute thrombotic CA occlusions were created just distal to the balloon catheter by injecting fresh autologous arterial thrombi. After angiographic documentation of occlusion, the common carotid thrombosis was treated with either diagnostic low MI imaging alone (0.2 MI; Philips S5-1) applied through a tissue mimicking phantom (TMP) or intermittent diagnostic high MI stable cavitation (SC)-inducing impulses with a longer pulse duration (0.8 MI; 20 microseconds' pulse duration) or inertial cavitation (IC) impulses (1.2 MI; 20 microseconds' pulse duration). All treatment times were for 30 minutes. Intravenous ultrasound contrast (2% Definity; Lantheus Medical) was infused during the treatment period. Angiographic recanalization in 4 intracranial and extracranial vessels downstream from the CA occlusion (auricular, ascending pharyngeal, buccinator, and maxillary) was assessed with both magnetic resonance 3-dimensional time-of-flight and phase contrast angiography. All magnetic resonance images were interpreted by an independent neuroradiologist using the thrombolysis in cerebral infarction (TICI) scoring system. By phase contrast angiography, at least mild recanalization (TICI 2a or higher) was seen in 64% of downstream vessels treated with SC impulses compared with 33% of IC treated and 29% of low MI alone treated downstream vessels (P = 0.001), whereas moderate or complete recanalization (TICI 2b or higher) was seen in 39% of SC treated vessels compared with 10% IC treated and 21% of low MI alone treated vessels (P = 0.001). High MI 20-microsecond pulse duration impulses during a commercial microbubble infusion can be used to recanalize acutely thrombosed carotid arteries and restore downstream flow without anticoagulants. However, this effect is only seen with SC-inducing impulses and not at higher mechanical indices, when a paradoxical reversal of the thrombolytic effect is observed. Diagnostic ultrasound-induced SC can be a nonsurgical method of dissolving CA thrombi and preventing thromboembolization.

  19. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    PubMed

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  20. Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging

    PubMed Central

    Pysz, Marybeth A.; Guracar, Ismayil; Foygel, Kira; Tian, Lu; Willmann, Jürgen K.

    2015-01-01

    Purpose To develop and test a real-time motion compensation algorithm for contrast-enhanced ultrasound imaging of tumor angiogenesis on a clinical ultrasound system. Materials and methods The Administrative Institutional Panel on Laboratory Animal Care approved all experiments. A new motion correction algorithm measuring the sum of absolute differences in pixel displacements within a designated tracking box was implemented in a clinical ultrasound machine. In vivo angiogenesis measurements (expressed as percent contrast area) with and without motion compensated maximum intensity persistence (MIP) ultrasound imaging were analyzed in human colon cancer xenografts (n = 64) in mice. Differences in MIP ultrasound imaging signal with and without motion compensation were compared and correlated with displacements in x- and y-directions. The algorithm was tested in an additional twelve colon cancer xenograft-bearing mice with (n = 6) and without (n = 6) anti-vascular therapy (ASA-404). In vivo MIP percent contrast area measurements were quantitatively correlated with ex vivo microvessel density (MVD) analysis. Results MIP percent contrast area was significantly different (P < 0.001) with and without motion compensation. Differences in percent contrast area correlated significantly (P < 0.001) with x- and y-displacements. MIP percent contrast area measurements were more reproducible with motion compensation (ICC = 0.69) than without (ICC = 0.51) on two consecutive ultrasound scans. Following anti-vascular therapy, motion-compensated MIP percent contrast area significantly (P = 0.03) decreased by 39.4 ± 14.6 % compared to non-treated mice and correlated well with ex vivo MVD analysis (Rho = 0.70; P = 0.05). Conclusion Real-time motion-compensated MIP ultrasound imaging allows reliable and accurate quantification and monitoring of angiogenesis in tumors exposed to breathing-induced motion artifacts. PMID:22535383

  1. Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging.

    PubMed

    Pysz, Marybeth A; Guracar, Ismayil; Foygel, Kira; Tian, Lu; Willmann, Jürgen K

    2012-09-01

    To develop and test a real-time motion compensation algorithm for contrast-enhanced ultrasound imaging of tumor angiogenesis on a clinical ultrasound system. The Administrative Institutional Panel on Laboratory Animal Care approved all experiments. A new motion correction algorithm measuring the sum of absolute differences in pixel displacements within a designated tracking box was implemented in a clinical ultrasound machine. In vivo angiogenesis measurements (expressed as percent contrast area) with and without motion compensated maximum intensity persistence (MIP) ultrasound imaging were analyzed in human colon cancer xenografts (n = 64) in mice. Differences in MIP ultrasound imaging signal with and without motion compensation were compared and correlated with displacements in x- and y-directions. The algorithm was tested in an additional twelve colon cancer xenograft-bearing mice with (n = 6) and without (n = 6) anti-vascular therapy (ASA-404). In vivo MIP percent contrast area measurements were quantitatively correlated with ex vivo microvessel density (MVD) analysis. MIP percent contrast area was significantly different (P < 0.001) with and without motion compensation. Differences in percent contrast area correlated significantly (P < 0.001) with x- and y-displacements. MIP percent contrast area measurements were more reproducible with motion compensation (ICC = 0.69) than without (ICC = 0.51) on two consecutive ultrasound scans. Following anti-vascular therapy, motion-compensated MIP percent contrast area significantly (P = 0.03) decreased by 39.4 ± 14.6 % compared to non-treated mice and correlated well with ex vivo MVD analysis (Rho = 0.70; P = 0.05). Real-time motion-compensated MIP ultrasound imaging allows reliable and accurate quantification and monitoring of angiogenesis in tumors exposed to breathing-induced motion artifacts.

  2. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    PubMed

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the concentration of microbubbles in case stable cavitation is predominant.

  3. A pilot study of comprehensive ultrasound education at the Wayne State University School of Medicine: a pioneer year review.

    PubMed

    Rao, Sishir; van Holsbeeck, Lodewijk; Musial, Joseph L; Parker, Alton; Bouffard, J Antonio; Bridge, Patrick; Jackson, Matt; Dulchavsky, Scott A

    2008-05-01

    Ultrasound is a versatile diagnostic modality used in a variety of medical fields. Wayne State University School of Medicine (WSUSOM) is one of the first medical schools in the United States to integrate an ultrasound curriculum through both basic science courses and clinical clerkships. In 2006, 25 portable ultrasound units were donated to WSUSOM. First-year medical students were provided an ultrasound curriculum consisting of 6 organ-system sessions that addressed the basics of ultrasound techniques, anatomy, and procedural skills. After the last session, students were administered 2 anonymous and voluntary evaluations. The first assessed their overall experience with the ultrasound curriculum, and the second assessed their technical skills in applying ultrasound techniques. Eighty-three percent of students agreed or strongly agreed that their experience with ultrasound education was positive. On the summative evaluation, nearly 91% of students agreed or strongly agreed that they would benefit from continued ultrasound education throughout their 4 years of medical school. Student performance on the technical assessment was also very positive, with mean class performance of 87%. As residency programs adopt ultrasound training, medical school faculty should consider incorporating ultrasound education into their curriculum. Portable ultrasound has the potential to be used in many different settings, including rural practice sites and sporting events. The WSUSOM committee's pilot ultrasound curriculum will continue to use student feedback to enhance the ultrasound experience, helping students prepare for challenges that they will face in the future.

  4. 2ND International Symposium on HIFU Therapy HIFU Seattle 2002

    DTIC Science & Technology

    2002-12-01

    Drug Delivery, and Sonodynamic Therapy. One can see from this topic coverage that the symposium was largely on HIFU (essentially the first five topics), yet also broad enough to cover most aspects of therapeutic ultrasound ....This book is a compilation of papers presented at the 2nd International Symposium on Therapeutic Ultrasound , held in Seattle, Washington, July 29...number of topic categories, viz., Clinical Studies, Laboratory Studies, Simulation and Monitoring, Dosimetry, Engineering, Lithotripsy, Ultrasound -Enhanced

  5. Ultrasound-guided drug delivery in cancer

    PubMed Central

    2017-01-01

    Recent advancements in ultrasound and microbubble (USMB) mediated drug delivery technology has shown that this approach can improve spatially confined delivery of drugs and genes to target tissues while reducing systemic dose and toxicity. The mechanism behind enhanced delivery of therapeutics is sonoporation, the formation of openings in the vasculature, induced by ultrasound-triggered oscillations and destruction of microbubbles. In this review, progress and challenges of USMB mediated drug delivery are summarized, with special focus on cancer therapy. PMID:28607323

  6. Validation of the DRAGON Score in a Chinese Population to Predict Functional Outcome of Intravenous Thrombolysis-Treated Stroke Patients.

    PubMed

    Zhang, Xinmiao; Liao, Xiaoling; Wang, Chunjuan; Liu, Liping; Wang, Chunxue; Zhao, Xingquan; Pan, Yuesong; Wang, Yilong; Wang, Yongjun

    2015-08-01

    The DRAGON score predicts functional outcome of ischemic stroke patients treated with intravenous thrombolysis. Our aim was to evaluate its utility in a Chinese stroke population. Patients with acute ischemic stroke treated with intravenous thrombolysis were prospectively registered in the Thrombolysis Implementation and Monitor of acute ischemic Stroke in China. We excluded patients with basilar artery occlusion and missing data, leaving 970 eligible patients. We calculated the DRAGON score, and the clinical outcome was measured by the modified Rankin Scale at 3 months. Model discrimination was quantified by calculating the C statistic. Calibration was assessed using Pearson correlation coefficient. The C statistic was .73 (.70-.76) for good outcome and .75 (.70-.79) for miserable outcome. Proportions of patients with good outcome were 94%, 83%, 70%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 3%, 9%, and 50% for 0 to 1, 2, 3, and 8 to 10 points, respectively. There was high correlation between predicted and observed probability of 3-month favorable and miserable outcome in the external validation cohort (Pearson correlation coefficient, .98 and .98, respectively, both P < .0001). The DRAGON score showed good performance to predict functional outcome after tissue-type plasminogen activator treatment in the Chinese population. This study demonstrated the accuracy and usability of the DRAGON score in the Chinese population in daily practice. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. Prospective evaluation of eligibility for thrombolytic therapy in acute myocardial infarction.

    PubMed Central

    French, J. K.; Williams, B. F.; Hart, H. H.; Wyatt, S.; Poole, J. E.; Ingram, C.; Ellis, C. J.; Williams, M. G.; White, H. D.

    1996-01-01

    OBJECTIVES--To determine the proportion of patients presenting with acute myocardial infarction who are eligible for thrombolytic therapy. DESIGN--Cohort follow up study. SETTING--The four coronary care units in Auckland, New Zealand. SUBJECTS--All 3014 patients presenting to the units with suspected myocardial infarction in 1993. MAIN OUTCOME MEASURES--Eligibility for reperfusion with thrombolytic therapy (presentation within 12 hours of the onset of ischaemic chest pain with ST elevation > or = 2 mm in leads V1-V3, ST elevation > or = 1 mm in any other two contiguous leads, or new left bundle branch block); proportions of (a) patients eligible for reperfusion and (b) patients with contraindications to thrombolysis; death (including causes); definite myocardial infarction. RESULTS--948 patients had definite myocardial infarction, 124 probable myocardial infarction, and nine ST elevation but no infarction; 1274 patients had unstable angina and 659 chest pain of other causes. Of patients with definite or probable myocardial infarction, 576 (53.3%) were eligible for reperfusion, 39 had definite contraindications to thrombolysis (risk of bleeding). Hence 49.7% of patients (537/1081) were eligible for thrombolysis and 43.5% (470) received this treatment. Hospital mortality among patients eligible for reperfusion was 11.7% (55/470 cases) among those who received thrombolysis and 17.0% (18/106) among those who did not. CONCLUSIONS--On current criteria about half of patients admitted to coronary care units with definite or probable myocardial infarction are eligible for thrombolytic therapy. Few eligible patients have definite contraindications to thrombolytic therapy. Mortality for all community admissions for myocardial infarction remains high. PMID:8664716

  8. [Management of patients treated for acute ST-elevation myocardial infarction in Tunisia: Preliminary results of FAST-MI Tunisia Registry from Tunisian Society of Cardiology and Cardiovascular Surgery].

    PubMed

    Addad, F; Gouider, J; Boughzela, E; Kamoun, S; Boujenah, R; Haouala, H; Gamra, H; Maatouk, F; Ben Khalfallah, A; Kachboura, S; Baccar, H; Ben Halima, N; Guesmi, A; Sayahi, K; Sdiri, W; Neji, A; Bouakez, A; Battikh, K; Chettaoui, R; Mourali, S

    2015-12-01

    FAST-MI Tunisian registry was initiated by the Tunisian Society of Cardiology and Cardio-vascular Surgery to assess characteristics, management, and hospital outcomes in patients with ST-elevation myocardial infarction (STEMI). We prospectively collected data from 203 consecutive patients (mean age 60.3 years, 79.8 % male) with STEMI who were treated in 15 public hospitals (representing 68.2 % of Tunisian public centres treating STEMI patients) during a 3-month period at the end of 2014. The most common risk factor was tobacco (64.9 %), hypertension (38.6 %), diabetes (36.9 %) and dyslipidemia (24.6 %). Among these patients, 66 % received reperfusion therapy, 35 % with primary percutaneous coronary interventions (PAMI), 31 % with thrombolysis (28.6 % of them by pre-hospital thrombolysis). The median time from symptom onset to thrombolysis was 185 and 358 min for PAMI, respectively. The in-hospital mortality was 7.0 %. Patients enrolled in interventional centers (n=156) were more likely to receive any reperfusion therapy (19.8 % vs 44.6 %; p<0.001) than at the regional system of care with less thrombolysis (26.9 % vs 44.6 %; p=0.008) and more PAMI (52.8 % vs 8.5 %; p<0.0001). Also the in-hospital mortality was lower (6.4 % vs 9.3 %) but not significant. Preliminary results from FAST-MI in Tunisia show that the pharmaco- invasive strategy should be promoted in non-interventional centers. Copyright © 2015. Published by Elsevier SAS.

  9. Cavitation and contrast: the use of bubbles in ultrasound imaging and therapy.

    PubMed

    Stride, E P; Coussios, C C

    2010-01-01

    Microbubbles and cavitation are playing an increasingly significant role in both diagnostic and therapeutic applications of ultrasound. Microbubble ultrasound contrast agents have been in clinical use now for more than two decades, stimulating the development of a range of new contrast-specific imaging techniques which offer substantial benefits in echocardiography, microcirculatory imaging, and more recently, quantitative and molecular imaging. In drug delivery and gene therapy, microbubbles are being investigated/developed as vehicles which can be loaded with the required therapeutic agent, traced to the target site using diagnostic ultrasound, and then destroyed with ultrasound of higher intensity energy burst to release the material locally, thus avoiding side effects associated with systemic administration, e.g. of toxic chemotherapy. It has moreover been shown that the motion of the microbubbles increases the permeability of both individual cell membranes and the endothelium, thus enhancing therapeutic uptake, and can locally increase the activity of drugs by enhancing their transport across biologically inaccessible interfaces such as blood clots or solid tumours. In high-intensity focused ultrasound (HIFU) surgery and lithotripsy, controlled cavitation is being investigated as a means of increasing the speed and efficacy of the treatment. The aim of this paper is both to describe the key features of the physical behaviour of acoustically driven bubbles which underlie their effectiveness in biomedical applications and to review the current state of the art.

  10. Contrast-Enhanced Ultrasound Improves the Pathological Outcomes of US-Guided Core Needle Biopsy That Targets the Viable Area of Anterior Mediastinal Masses

    PubMed Central

    Zhou, Jian-hua; Shan, Hong-bo; Ou, Wei; Mo, Yun-xian; Xiang, Jin; Wang, Yu; Wang, Si-yu

    2018-01-01

    Based on the option that ultrasound-guided core needle biopsy (US-CNB) of the enhanced portion of anterior mediastinal masses (AMMs) identified by contrast-enhanced ultrasound (CEUS) would harvest viable tissue and benefit the histological diagnoses, a retrospective study was performed to elucidate the correlation between the prebiopsy CEUS and diagnostic yield of AMMs and found that CEUS potentially improved the diagnostic yield of AMMs compared with conventional US with a significant increase in the cellularity of samples. Furthermore, the marginal blood flow signals and absence of necrosis can predict the diagnostic yield of AMM. It was concluded that US-CNB of the viable part of AMMs, as verified by CEUS, was able to harvest sufficient tissue with more cellularity that could be used for ancillary studies and improve the diagnostic yield. And CEUS was recommended to those patients with AMMs undergoing repeated US-CNB, with the absence of marginal blood signals or presence of necrosis. PMID:29581992

  11. Intense acoustic bursts as a signal-enhancement mechanism in ultrasound-modulated optical tomography.

    PubMed

    Kim, Chulhong; Zemp, Roger J; Wang, Lihong V

    2006-08-15

    Biophotonic imaging with ultrasound-modulated optical tomography (UOT) promises ultrasonically resolved imaging in biological tissues. A key challenge in this imaging technique is a low signal-to-noise ratio (SNR). We show significant UOT signal enhancement by using intense time-gated acoustic bursts. A CCD camera captured the speckle pattern from a laser-illuminated tissue phantom. Differences in speckle contrast were observed when ultrasonic bursts were applied, compared with when no ultrasound was applied. When CCD triggering was synchronized with burst initiation, acoustic-radiation-force-induced displacements were detected. To avoid mechanical contrast in UOT images, the CCD camera acquisition was delayed several milliseconds until transient effects of acoustic radiation force attenuated to a satisfactory level. The SNR of our system was sufficiently high to provide an image pixel per acoustic burst without signal averaging. Because of the substantially improved SNR, the use of intense acoustic bursts is a promising signal enhancement strategy for UOT.

  12. Low-intensity focused ultrasound (LIFU)-induced acoustic droplet vaporization in phase-transition perfluoropentane nanodroplets modified by folate for ultrasound molecular imaging.

    PubMed

    Liu, Jianxin; Shang, Tingting; Wang, Fengjuan; Cao, Yang; Hao, Lan; Ren, JianLi; Ran, Haitao; Wang, Zhigang; Li, Pan; Du, Zhiyu

    2017-01-01

    The commonly used ultrasound (US) molecular probes, such as targeted microbubbles and perfluorocarbon emulsions, present a number of inherent problems including the conflict between US visualization and particle penetration. This study describes the successful fabrication of phase changeable folate-targeted perfluoropentane nanodroplets (termed FA-NDs), a novel US molecular probe for tumor molecular imaging with US. Notably, these FA-NDs can be triggered by low-intensity focused US (LIFU) sonication, providing excellent US enhancement in B-mode and contrast-enhanced US mode in vitro. After intravenous administration into nude mice bearing SKOV3 ovarian carcinomas, 1,1'-dioctadecyl-3,3,3',3' -tetramethylindotricarbocya-nine iodide-labeled FA-NDs were found to accumulate in the tumor region. FA-NDs injection followed by LIFU sonication exhibited remarkable US contrast enhancement in the tumor region. In conclusion, combining our elaborately developed FA-NDs with LIFU sonication provides a potential protocol for US molecular imaging in folate receptor-overexpressing tumors.

  13. Low-intensity focused ultrasound (LIFU)-induced acoustic droplet vaporization in phase-transition perfluoropentane nanodroplets modified by folate for ultrasound molecular imaging

    PubMed Central

    Liu, Jianxin; Shang, Tingting; Wang, Fengjuan; Cao, Yang; Hao, Lan; Ren, JianLi; Ran, Haitao; Wang, Zhigang; Li, Pan; Du, Zhiyu

    2017-01-01

    The commonly used ultrasound (US) molecular probes, such as targeted microbubbles and perfluorocarbon emulsions, present a number of inherent problems including the conflict between US visualization and particle penetration. This study describes the successful fabrication of phase changeable folate-targeted perfluoropentane nanodroplets (termed FA-NDs), a novel US molecular probe for tumor molecular imaging with US. Notably, these FA-NDs can be triggered by low-intensity focused US (LIFU) sonication, providing excellent US enhancement in B-mode and contrast-enhanced US mode in vitro. After intravenous administration into nude mice bearing SKOV3 ovarian carcinomas, 1,1′-dioctadecyl-3,3,3′,3′ -tetramethylindotricarbocya-nine iodide-labeled FA-NDs were found to accumulate in the tumor region. FA-NDs injection followed by LIFU sonication exhibited remarkable US contrast enhancement in the tumor region. In conclusion, combining our elaborately developed FA-NDs with LIFU sonication provides a potential protocol for US molecular imaging in folate receptor-overexpressing tumors. PMID:28184161

  14. Intravenous and Intracavitary Use of Contrast-Enhanced Ultrasound in the Evaluation and Management of Complicated Pediatric Pneumonia.

    PubMed

    Deganello, Annamaria; Rafailidis, Vasileios; Sellars, Maria E; Ntoulia, Aikaterini; Kalogerakou, Kleanthi; Ruiz, Gary; Cosgrove, David O; Sidhu, Paul S

    2017-09-01

    Pediatric pneumonia can be complicated by necrotizing pneumonia or a parapneumonic effusion either in the form of an empyema or a clear effusion. Ultrasonography (US) and computed tomography represent well-established modalities for evaluation of complicated pediatric pneumonia. Contrast-enhanced ultrasound (CEUS) was recently introduced and is gaining increasing acceptance in pediatric imaging. In this case series, we present our initial experience with both intravenous and intracavitary use of CEUS in children with complicated pneumonia. Intravenous CEUS accurately and confidently showed necrotizing pneumonia and delineated pleural effusions, whereas intracavitary CEUS accurately identified the chest catheter location and patency and showed the presence of loculations, suggesting the use of fibrinolytics. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Simulations of laser thrombolysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapyak, E.J.; Godwin, R.P.

    1999-03-01

    The authors have shown that bubble expansion and collapse near the interface between two materials with modest property differences produces jet-like interpenetration of the two materials. The bubble dynamics at a water-viscous fluid interface is compared with that at the interface of water with a weak elastic-plastic material. The authors find that, despite rather similar behavior during bubble growth and the initial portion of bubble collapse, the terminal jetting behavior is quite different, even in direction. The elastic-plastic properties chosen realistically represent real and surrogate thrombus. Simulations using the elastic-plastic model quantitatively agree with laboratory thrombolysis mass removal experiments. Inmore » the earlier simulations of laboratory experiments, walls have been remote so as to not effect the dynamics. Here the authors present two-dimensional simulations of thrombolysis with water over elastic-plastic surrogate thrombus in a geometry representative of the clinical situation. The calculations include thin cylindrical elastic walls with properties and dimensions appropriate for arteries. The presence of these artery walls does not substantially change the interface jetting predicted in unconfined simulations.« less

  16. National Practice Patterns of Obtaining Informed Consent for Stroke Thrombolysis.

    PubMed

    Mendelson, Scott J; Courtney, D Mark; Gordon, Elisa J; Thomas, Leena F; Holl, Jane L; Prabhakaran, Shyam

    2018-03-01

    No standard approach to obtaining informed consent for stroke thrombolysis with tPA (tissue-type plasminogen activator) currently exists. We aimed to assess current nationwide practice patterns of obtaining informed consent for tPA. An online survey was developed and distributed by e-mail to clinicians involved in acute stroke care. Multivariable logistic regression analyses were performed to determine independent factors contributing to always obtaining informed consent for tPA. Among 268 respondents, 36.7% reported always obtaining informed consent and 51.8% reported the informed consent process caused treatment delays. Being an emergency medicine physician (odds ratio, 5.8; 95% confidence interval, 2.9-11.5) and practicing at a nonacademic medical center (odds ratio, 2.1; 95% confidence interval, 1.0-4.3) were independently associated with always requiring informed consent. The most commonly cited cause of delay was waiting for a patient's family to reach consensus about treatment. Most clinicians always or often require informed consent for stroke thrombolysis. Future research should focus on standardizing content and delivery of tPA information to reduce delays. © 2018 American Heart Association, Inc.

  17. Vascular complications following prophylactic balloon occlusion of the internal iliac arteries resolved by successful interventional thrombolysis in a patient with morbidly adherent placenta*

    PubMed Central

    Zhang, Ning; Lou, Wei-hua; Zhang, Xue-bin; Fu, Jia-ning; Chen, Yun-yan; Zhuang, Zhi-guo; Lin, Jian-hua

    2017-01-01

    The increasing incidence of morbidly adherent placenta (MAP) is placing women at a higher risk of life-threatening massive hemorrhage. The involvement of interventional radiology to manage this complex condition by performing prophylactic iliac artery balloon occlusion has been reported recently. However, the effectiveness and safety of this technique have not been fully determined. Here we report the case of a 25-year-old woman with placenta increta with preemptive bilateral internal iliac artery balloons who had external iliac artery thrombosis detected by computed tomography angiography (CTA) 72 h post cesarean section. A digital subtraction angiogram (DSA) and intra-arterial thrombolysis were instantly performed followed by supplementary conservative treatments, leading to a desirable resolution of thrombus without sequela. This is the first report of vascular complications with successful interventional thrombolysis in this setting. Our experience suggests that prophylactic iliac artery balloon occlusion should be used cautiously in cases of MAP and consideration given to minimizing vascular complications given the hypercoagulable state of pregnancy. PMID:28271663

  18. The effect of the sample size and location on contrast ultrasound measurement of perfusion parameters.

    PubMed

    Leinonen, Merja R; Raekallio, Marja R; Vainio, Outi M; Ruohoniemi, Mirja O; O'Brien, Robert T

    2011-01-01

    Contrast-enhanced ultrasound can be used to quantify tissue perfusion based on region of interest (ROI) analysis. The effect of the location and size of the ROI on the obtained perfusion parameters has been described in phantom, ex vivo and in vivo studies. We assessed the effects of location and size of the ROI on perfusion parameters in the renal cortex of 10 healthy, anesthetized cats using Definity contrast-enhanced ultrasound to estimate the importance of the ROI on quantification of tissue perfusion with contrast-enhanced ultrasound. Three separate sets of ROIs were placed in the renal cortex, varying in location, size or depth. There was a significant inverse association between increased depth or increased size of the ROI and peak intensity (P < 0.05). There was no statistically significant difference in the peak intensity between the ROIs placed in a row in the near field cortex. There was no significant difference in the ROIs with regard to arrival time, time to peak intensity and wash-in rate. When comparing two different ROIs in a patient with focal lesions, such as suspected neoplasia or infarction, the ROIs should always be placed at same depth and be as similar in size as possible.

  19. Preliminary results in large bone segmentation from 3D freehand ultrasound

    NASA Astrophysics Data System (ADS)

    Fanti, Zian; Torres, Fabian; Arámbula Cosío, Fernando

    2013-11-01

    Computer Assisted Orthopedic Surgery (CAOS) requires a correct registration between the patient in the operating room and the virtual models representing the patient in the computer. In order to increase the precision and accuracy of the registration a set of new techniques that eliminated the need to use fiducial markers have been developed. The majority of these newly developed registration systems are based on costly intraoperative imaging systems like Computed Tomography (CT scan) or Magnetic resonance imaging (MRI). An alternative to these methods is the use of an Ultrasound (US) imaging system for the implementation of a more cost efficient intraoperative registration solution. In order to develop the registration solution with the US imaging system, the bone surface is segmented in both preoperative and intraoperative images, and the registration is done using the acquire surface. In this paper, we present the a preliminary results of a new approach to segment bone surface from ultrasound volumes acquired by means 3D freehand ultrasound. The method is based on the enhancement of the voxels that belongs to surface and its posterior segmentation. The enhancement process is based on the information provided by eigenanalisis of the multiscale 3D Hessian matrix. The preliminary results shows that from the enhance volume the final bone surfaces can be extracted using a singular value thresholding.

  20. In Vivo Targeted, Responsive, and Synergistic Cancer Nanotheranostics by Magnetic Resonance Imaging-Guided Synergistic High-Intensity Focused Ultrasound Ablation and Chemotherapy.

    PubMed

    Tang, Hailin; Guo, Yuan; Peng, Li; Fang, Hui; Wang, Zhigang; Zheng, Yuanyi; Ran, Haitao; Chen, Yu

    2018-05-09

    As one of the most representative noninvasive therapeutic modalities, high-intensity focused ultrasound (HIFU) has shown great promise for cancer therapy, but its low therapeutic efficacy and biosafety significantly hinder further extensive clinical translation and application. In this work, we report on the construction of a multifunctional theranostic nanoplatform to synergistically enhance the HIFU-therapeutic efficacy based on nanomedicine. A targeted and temperature-responsive theranostic nanoplatform (PFH/DOX@PLGA/Fe 3 O 4 -FA) has been designed and fabricated for efficient ultrasound/magnetic resonance dual-modality imaging-guided HIFU/chemo synergistic therapy. Especially, the folate was conjugated onto the surface of the nanoplatform for achieving active targeting to hepatoma cells by receptor-ligand interaction, which facilitates accumulation of the nanoplatforms into the tumor site. The integrated superparamagnetic iron oxide nanoparticles could generate the contrast enhancement in T 2 -weighted magnetic resonance imaging. By virtue of the thermal effect as generated by HIFU, liquid-gas phase transition of perfluorohexane (PFH) in nanocomposites was induced to generate PFH microbubbles, which achieved the contrast-enhanced ultrasound imaging and significantly improved the HIFU ablation efficacy. The loaded anticancer drugs could be released from the nanocomposites in a controllable manner (both pH and HIFU responsiveness). These multifunctional nanocomposites have been demonstrated to efficiently suppress the tumor growth based on the enhanced and synergistic chemotherapy and HIFU ablation, providing an efficient theranostic nanoplatform for cancer treatment.

  1. Phase-shift perfluorocarbon agents enhance high intensity focused ultrasound thermal delivery with reduced near-field heating

    PubMed Central

    Phillips, Linsey C.; Puett, Connor; Sheeran, Paul S.; Dayton, Paul A.; Wilson Miller, G.; Matsunaga, Terry O.

    2013-01-01

    Ultrasound contrast agents are known to enhance high intensity focused ultrasound (HIFU) ablation, but these perfluorocarbon microbubbles are limited to the vasculature, have a short half-life in vivo, and may result in unintended heating away from the target site. Herein, a nano-sized (100–300 nm), dual perfluorocarbon (decafluorobutane/dodecafluoropentane) droplet that is stable, is sufficiently small to extravasate, and is convertible to micron-sized bubbles upon acoustic activation was investigated. Microbubbles and nanodroplets were incorporated into tissue-mimicking acrylamide-albumin phantoms. Microbubbles or nanodroplets at 0.1 × 106 per cm3 resulted in mean lesion volumes of 80.4 ± 33.1 mm3 and 52.8 ± 14.2 mm3 (mean ± s.e.), respectively, after 20 s of continuous 1 MHz HIFU at a peak negative pressure of 4 MPa, compared to a lesion volume of 1.0 ± 0.8 mm3 in agent-free control phantoms. Magnetic resonance thermometry mapping during HIFU confirmed undesired surface heating in phantoms containing microbubbles, whereas heating occurred at the acoustic focus of phantoms containing the nanodroplets. Maximal change in temperature at the target site was enhanced by 16.9% and 37.0% by microbubbles and nanodroplets, respectively. This perfluorocarbon nanodroplet has the potential to reduce the time to ablate tumors by one-third during focused ultrasound surgery while also safely enhancing thermal deposition at the target site. PMID:23927187

  2. Rayleigh-maximum-likelihood bilateral filter for ultrasound image enhancement.

    PubMed

    Li, Haiyan; Wu, Jun; Miao, Aimin; Yu, Pengfei; Chen, Jianhua; Zhang, Yufeng

    2017-04-17

    Ultrasound imaging plays an important role in computer diagnosis since it is non-invasive and cost-effective. However, ultrasound images are inevitably contaminated by noise and speckle during acquisition. Noise and speckle directly impact the physician to interpret the images and decrease the accuracy in clinical diagnosis. Denoising method is an important component to enhance the quality of ultrasound images; however, several limitations discourage the results because current denoising methods can remove noise while ignoring the statistical characteristics of speckle and thus undermining the effectiveness of despeckling, or vice versa. In addition, most existing algorithms do not identify noise, speckle or edge before removing noise or speckle, and thus they reduce noise and speckle while blurring edge details. Therefore, it is a challenging issue for the traditional methods to effectively remove noise and speckle in ultrasound images while preserving edge details. To overcome the above-mentioned limitations, a novel method, called Rayleigh-maximum-likelihood switching bilateral filter (RSBF) is proposed to enhance ultrasound images by two steps: noise, speckle and edge detection followed by filtering. Firstly, a sorted quadrant median vector scheme is utilized to calculate the reference median in a filtering window in comparison with the central pixel to classify the target pixel as noise, speckle or noise-free. Subsequently, the noise is removed by a bilateral filter and the speckle is suppressed by a Rayleigh-maximum-likelihood filter while the noise-free pixels are kept unchanged. To quantitatively evaluate the performance of the proposed method, synthetic ultrasound images contaminated by speckle are simulated by using the speckle model that is subjected to Rayleigh distribution. Thereafter, the corrupted synthetic images are generated by the original image multiplied with the Rayleigh distributed speckle of various signal to noise ratio (SNR) levels and added with Gaussian distributed noise. Meanwhile clinical breast ultrasound images are used to visually evaluate the effectiveness of the method. To examine the performance, comparison tests between the proposed RSBF and six state-of-the-art methods for ultrasound speckle removal are performed on simulated ultrasound images with various noise and speckle levels. The results of the proposed RSBF are satisfying since the Gaussian noise and the Rayleigh speckle are greatly suppressed. The proposed method can improve the SNRs of the enhanced images to nearly 15 and 13 dB compared with images corrupted by speckle as well as images contaminated by speckle and noise under various SNR levels, respectively. The RSBF is effective in enhancing edge while smoothing the speckle and noise in clinical ultrasound images. In the comparison experiments, the proposed method demonstrates its superiority in accuracy and robustness for denoising and edge preserving under various levels of noise and speckle in terms of visual quality as well as numeric metrics, such as peak signal to noise ratio, SNR and root mean squared error. The experimental results show that the proposed method is effective for removing the speckle and the background noise in ultrasound images. The main reason is that it performs a "detect and replace" two-step mechanism. The advantages of the proposed RBSF lie in two aspects. Firstly, each central pixel is classified as noise, speckle or noise-free texture according to the absolute difference between the target pixel and the reference median. Subsequently, the Rayleigh-maximum-likelihood filter and the bilateral filter are switched to eliminate speckle and noise, respectively, while the noise-free pixels are unaltered. Therefore, it is implemented with better accuracy and robustness than the traditional methods. Generally, these traits declare that the proposed RSBF would have significant clinical application.

  3. SURGE: Smart Ultrasound Remote Guidance Experiment

    NASA Technical Reports Server (NTRS)

    Peterson, Sean

    2009-01-01

    Exploration-class missions lead to longer communication delays with mission control. May not always have communication capability to stream real-time ultrasound images. SURGE explores use of a "just-in-time" learning tool, called OPEL = On-Board Proficiency Enhancer Light as an aid to a hypothetical crew medical officer working autonomously.

  4. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    NASA Astrophysics Data System (ADS)

    Demi, Libertario; van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2015-10-01

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO® UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

  5. Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging.

    PubMed

    Bandaru, Raja Sekhar; Sornes, Anders Rasmus; Hermans, Jeroen; Samset, Eigil; D'hooge, Jan

    2016-12-01

    Although interventional devices, such as needles, guide wires, and catheters, are best visualized by X-ray, real-time volumetric echography could offer an attractive alternative as it avoids ionizing radiation; it provides good soft tissue contrast, and it is mobile and relatively cheap. Unfortunately, as echography is traditionally used to image soft tissue and blood flow, the appearance of interventional devices in conventional ultrasound images remains relatively poor, which is a major obstacle toward ultrasound-guided interventions. The objective of this paper was therefore to enhance the appearance of interventional devices in ultrasound images. Thereto, a modified ultrasound beamforming process using conventional-focused transmit beams is proposed that exploits the properties of received signals containing specular reflections (as arising from these devices). This new beamforming approach referred to as delay and standard deviation beamforming (DASD) was quantitatively tested using simulated as well as experimental data using a linear array transducer. Furthermore, the influence of different imaging settings (i.e., transmit focus, imaging depth, and scan angle) on the obtained image contrast was evaluated. The study showed that the image contrast of specular regions improved by 5-30 dB using DASD beamforming compared with traditional delay and sum (DAS) beamforming. The highest gain in contrast was observed when the interventional device was tilted away from being orthogonal to the transmit beam, which is a major limitation in standard DAS imaging. As such, the proposed beamforming methodology can offer an improved visualization of interventional devices in the ultrasound image with potential implications for ultrasound-guided interventions.

  6. Neurosurgical Applications of High-Intensity Focused Ultrasound with Magnetic Resonance Thermometry.

    PubMed

    Colen, Rivka R; Sahnoune, Iman; Weinberg, Jeffrey S

    2017-10-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) has potential noninvasive effects on targeted tissue. MRgFUS integrates MRI and focused ultrasound surgery (FUS) into a single platform. MRI enables visualization of the target tissue and monitors ultrasound-induced effects in near real-time during FUS treatment. MRgFUS may serve as an adjunct or replace invasive surgery and radiotherapy for specific conditions. Its thermal effects ablate tumors in locations involved in movement disorders and essential tremors. Its nonthermal effects increase blood-brain barrier permeability to enhance delivery of therapeutics and other molecules. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. High-intensity focused ultrasound: advances in technology and experimental trials support enhanced utility of focused ultrasound surgery in oncology

    PubMed Central

    Malietzis, G; Monzon, L; Hand, J; Wasan, H; Leen, E; Abel, M; Muhammad, A; Abel, P

    2013-01-01

    High-intensity focused ultrasound (HIFU) is a rapidly maturing technology with diverse clinical applications. In the field of oncology, the use of HIFU to non-invasively cause tissue necrosis in a defined target, a technique known as focused ultrasound surgery (FUS), has considerable potential for tumour ablation. In this article, we outline the development and underlying principles of HIFU, overview the limitations and commercially available equipment for FUS, then summarise some of the recent technological advances and experimental clinical trials that we predict will have a positive impact on extending the role of FUS in cancer therapy. PMID:23403455

  8. Ultrasound-mediated destruction of oxygen and paclitaxel loaded lipid microbubbles for combination therapy in hypoxic ovarian cancer cells.

    PubMed

    Sun, Jiangchuan; Yin, Mingyue; Zhu, Shenyin; Liu, Li; Zhu, Yi; Wang, Zhigang; Xu, Ronald X; Chang, Shufang

    2016-01-01

    We synthesized oxygen and paclitaxel (PTX) loaded lipid microbubbles (OPLMBs) for ultrasound mediated combination therapy in hypoxic ovarian cancer cells. Our experiments successfully demonstrated that ultrasound induced OPLMBs destruction significantly enhanced the local oxygen release. We also demonstrated that OPLMBs in combination with ultrasound (300 kHz, 0.5 W/cm(2), 15s) yielded anti-proliferative activities of 52.8 ± 2.75% and cell apoptosis ratio of 35.25 ± 0.17% in hypoxic cells at 24h after the treatment, superior to other treatment groups such as PTX only and PTX-loaded MBs (PLMBs) with or without ultrasound mediation. RT-PCR and Western blot tests further confirmed the reduced expression of HIF-1α and MDR-1/P-gp after ultrasound mediation of OPLMBs. Our experiment suggests that ultrasound mediation of oxygen and drug-loaded MBs may be a useful method to overcome chemoresistance in the hypoxic ovarian cancer cells. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Advanced Ultrasound Technologies for Diagnosis and Therapy.

    PubMed

    Rix, Anne; Lederle, Wiltrud; Theek, Benjamin; Lammers, Twan; Moonen, Chrit; Schmitz, Georg; Kiessling, Fabian

    2018-05-01

    Ultrasound is among the most rapidly advancing imaging techniques. Functional methods such as elastography have been clinically introduced, and tissue characterization is improved by contrast-enhanced scans. Here, novel superresolution techniques provide unique morphologic and functional insights into tissue vascularization. Functional analyses are complemented by molecular ultrasound imaging, to visualize markers of inflammation and angiogenesis. The full potential of diagnostic ultrasound may become apparent by integrating these multiple imaging features in radiomics approaches. Emerging interest in ultrasound also results from its therapeutic potential. Various applications of tumor ablation with high-intensity focused ultrasound are being clinically evaluated, and its performance strongly benefits from the integration into MRI. Additionally, oscillating microbubbles mediate sonoporation to open biologic barriers, thus improving the delivery of drugs or nucleic acids that are coadministered or coformulated with microbubbles. This article provides an overview of recent developments in diagnostic and therapeutic ultrasound, highlighting multiple innovation tracks and their translational potential. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  10. Ultrasound-mediated drug delivery using liposomes modified with a thermosensitive polymer.

    PubMed

    Ninomiya, Kazuaki; Kawabata, Shinya; Tashita, Hiroyuki; Shimizu, Nobuaki

    2014-01-01

    Ultrasound-mediated drug delivery was established using liposomes that were modified with the thermosensitive polymer (TSP) poly(NIPMAM-co-NIPAM), which sensitized the liposomes to high temperatures. TSP-modified liposomes (TSP liposomes) released encapsulated calcein under 1 MHz ultrasound irradiation at 0.5 W/cm(2) for 120 s as well as the case under incubation at 42 °C for 15 min. In addition, uptake of the drug released from TSP liposomes by cancer cells was enhanced by ultrasound irradiation. In a cell injury assay using doxorubicin (DOX)-loaded TSP liposomes and ultrasound irradiation, cell viability of HepG2 cells at 6 h after ultrasound irradiation (1 MHz, 0.5 W/cm(2) for 30 s) with DOX-loaded TSP liposomes (TSP/lipid ratio=1) was 60%, which was significantly lower than that of the control conditions such as DOX-loaded TSP liposomes alone and DOX-loaded intact liposomes under ultrasound irradiation. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Characteristics of pectinase treated with ultrasound both during and after the immobilization process.

    PubMed

    Ma, Xiaobin; Wang, Danli; Yin, Michelle; Lucente, Juliet; Wang, Wenjun; Ding, Tian; Ye, Xingqian; Liu, Donghong

    2017-05-01

    In this study, ultrasound was applied both during and after the immobilization process and characteristics of different immobilized pectinase samples were studied. When introduced during the immobilization process, ultrasound at an intensity of 9WmL -1 for 20min increased the immobilization yield 92.28% more than the control. When introduced to the already immobilized pectinase, ultrasound at an intensity of 4.5WmL -1 for 10min increased the pectinase activity by 30.05%. Results of scanning electron microscope demonstrated that ultrasound increased surface area and loosened structures of immobilized enzymes. Higher V max and lower K m were obtained after ultrasound treatment, indicating the increased catalytic efficiency and enhanced affinity of immobilized pectinase. Furthermore, the optimum temperature and pH for free and immobilized pectinase remained unchanged at 50°C and pH 4. Thermostability, reaction stability and reusability of two ultrasound-treated pectinase enzymes slightly decreased due to structural matrix changes. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. [Polymeric drug carriers activated by ultrasounds energy].

    PubMed

    Kik, Krzysztof; Lwow, Felicja; Szmigiero, Leszek

    2007-01-01

    In the last two decades an extensive research on the employment of ultrasounds in anticancer therapy has been noticed. So far ultrasounds have been widely used in medicine for diagnostic purposes (ultrasonography), but their great therapeutic potential and the development of polymer based antineoplastic drug carriers have persuaded many investigators to start research on the employment of ultrasounds in anticancer therapy. A new therapeutic concept based on the controlled drug's molecules release from their transporting polymer carriers has been proposed. Cavitation, a phenomenon characteristic for the action of ultrasounds, is used to destroy polymeric drug carriers and for drug release in target sites. The sonodynamic therapy (SDT) which utilizes ultrasonic waves for "acoustic drug activation" leading to the enhancement of cytotoxic activity of some drugs has also been developed. Furthermore, a long standing research on ultrasounds resulted in a new concept based on hyperthermia. This method of cancer treatment does not require any chemotherapeutic agent to be applied.

  13. Motion Detection in Ultrasound Image-Sequences Using Tensor Voting

    NASA Astrophysics Data System (ADS)

    Inba, Masafumi; Yanagida, Hirotaka; Tamura, Yasutaka

    2008-05-01

    Motion detection in ultrasound image sequences using tensor voting is described. We have been developing an ultrasound imaging system adopting a combination of coded excitation and synthetic aperture focusing techniques. In our method, frame rate of the system at distance of 150 mm reaches 5000 frame/s. Sparse array and short duration coded ultrasound signals are used for high-speed data acquisition. However, many artifacts appear in the reconstructed image sequences because of the incompleteness of the transmitted code. To reduce the artifacts, we have examined the application of tensor voting to the imaging method which adopts both coded excitation and synthetic aperture techniques. In this study, the basis of applying tensor voting and the motion detection method to ultrasound images is derived. It was confirmed that velocity detection and feature enhancement are possible using tensor voting in the time and space of simulated ultrasound three-dimensional image sequences.

  14. A brief history of ultrasound in rheumatology: where we were.

    PubMed

    Grassi, Walter; Filippucci, Emilio

    2014-01-01

    Ultrasonography in the '70s was a well-known and widely used method within several medical specialties but not in rheumatology. Initial development of the field was led by radiologists who mainly investigated the potential of ultrasound in the assessment of large joints. In the late '80s, the first studies supporting the role of ultrasound in the detection of soft tissue changes and bone erosions in the hands of patients with rheumatoid arthritis were published. In the '90s, the dramatic improvement of spatial resolution due to the new generation high frequency probes opened up new avenues for the exploration of otherwise undetectable anatomical details. Ultrasound research during this period was enhanced by the growing use of colour Doppler and power Doppler and by the first prototypes of three dimensional ultrasound. Over the last 10 years, the buzz words in ultrasound research in rheumatology have been standardisation, early diagnosis and therapy monitoring.

  15. The growth of oscillating bubbles in an ultrasound field

    NASA Astrophysics Data System (ADS)

    Yamauchi, Risa; Yamashita, Tatsuya; Ando, Keita

    2017-11-01

    From our recent experiments to test particle removal by underwater ultrasound, dissolved gas supersaturation is found to play an important role in physical cleaning; cavitation bubble nucleation can be triggered easily by weak ultrasound under the supersaturation and mild motion of the bubbles contributes to efficient cleaning without erosion. The state of gas bubble nuclei in water is critical to the determination of a cavitation inception threshold. Under ultrasound forcing, the size of bubble nuclei is varied by the transfer of dissolved gas (i.e., rectified diffusion); the growth rate will be promoted by the supersaturation and is thus expected to contribute to cavitation activity enhancement. In the present work, we experimentally study rectified diffusion for bubbles attached at glass surfaces in an ultrasound field. We will present the evolution of bubble nuclei sizes with varying parameters such as dissolved oxygen supersaturation, and ultrasound intensity and frequency. the Research Grant of Keio Leading-edge Laboratory of Science & Technology.

  16. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  17. Successful Recanalization of Acute Superior Mesenteric Artery Thromboembolic Occlusion by a Combination of Intraarterial Thrombolysis and Mechanical Thrombectomy with a Carotid Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zelenak, Kamil, E-mail: zelenak@unm.sk; Sinak, Igor; Janik, Jan

    2013-06-15

    Acute superior mesenteric artery (SMA) occlusion is a life-threatening disease, and acute intestinal ischemia develops from the sudden decrease in perfusion to the intestines. The key to saving the patient's life is early diagnosis, and prompt revascularization of the SMA can prevent intestinal infarction and decrease the risk of bowel segment necrosis. Computed tomographic angiography may be useful for rapid diagnosis. We report recanalization of an SMA occlusion in an 80-year-old man with a combination of intraarterial thrombolysis and mechanical thrombectomy with a carotid filter.

  18. Feasibility of Dual Optics/Ultrasound Imaging and Contrast Media for the Detection and Characterization of Prostate Cancer

    DTIC Science & Technology

    2009-03-01

    acousto - optic effect will be used to only modulate light (at the ultrasound frequency) which propagates through a small ultrasound focal zone. This...DOD Idea Development Award is concerned with the development of a novel acousto - optic detection idea based on quadrature measurements with a gain...perform acousto - optic molecular imaging of prostate cancer with incoherent photons using endogenous contrast, e.g. hypoxia, and with fluorescent probes and microbubbles for increased specificity and signal enhancement.

  19. Mesoporous silica nanoparticles engineered for ultrasound-induced uptake by cancer cells.

    PubMed

    Paris, Juan L; Manzano, Miguel; Cabañas, M Victoria; Vallet-Regí, María

    2018-04-05

    A novel smart hierarchical ultrasound-responsive mesoporous silica nanocarrier for cancer therapy is presented here. This dynamic nanosystem has been designed to display different surface characteristics during its journey towards tumor cells. Initially, the anticancer-loaded nanocarriers are shielded with a polyethylene glycol layer. Upon exposure to high frequency ultrasound, the polymer shell detaches from the nanoparticles, exposing a positively charged surface. This favors the internalization in human osteosarcoma cells, where the release of topotecan takes place, drastically enhancing the cytotoxic effect.

  20. Molecular imaging with targeted contrast ultrasound.

    PubMed

    Piedra, Mark; Allroggen, Achim; Lindner, Jonathan R

    2009-01-01

    Molecular imaging with contrast-enhanced ultrasound uses targeted microbubbles that are retained in diseased tissue. The resonant properties of these microbubbles produce acoustic signals in an ultrasound field. The microbubbles are targeted to diseased tissue by using certain chemical constituents in the microbubble shell or by attaching disease-specific ligands such as antibodies to the microbubble. In this review, we discuss the applications of this technique to pathological states in the cerebrovascular system including atherosclerosis, tumor angiogenesis, ischemia, intravascular thrombus, and inflammation. Copyright 2009 S. Karger AG, Basel.

  1. Value of CT added to ultrasonography for the diagnosis of lymph node metastasis in patients with thyroid cancer.

    PubMed

    Lee, Younghen; Kim, Ji-Hoon; Baek, Jung Hwan; Jung, So Lyung; Park, Sun-Won; Kim, Jinna; Yun, Tae Jin; Ha, Eun Ju; Lee, Kyu Eun; Kwon, Soon Young; Yang, Kyung-Sook; Na, Dong Gyu

    2018-05-13

    The benefit of CT for the diagnosis of lymph node metastasis in patients with thyroid cancer is still unclear. Three hundred fifty-one patients with thyroid cancers from 7 hospitals were prospectively enrolled in order to compare diagnostic performance between a combination of ultrasound and CT (ultrasound/CT) and ultrasound alone for prediction of lymph node metastasis and to calculate patient-based benefits of CT added to ultrasound. Of 801 pathologically proven neck levels, ultrasound/CT showed higher sensitivities in both central and lateral compartments and improved accuracy in the lateral compartment compared to ultrasound alone. In the retropharyngeal/superior mediastinal compartment, although CT could detect lymph node metastasis an ultrasound could not. Patient-based benefit was demonstrated in 13.1% of patients (46/351), and was higher in patients with cancers >1 cm than cancers ≤1 cm. In patients with thyroid cancer, CT improved surgical planning by enhancing the sensitivity for lymph node metastasis and by detecting lymph node metastasis that was overlooked with ultrasound alone. © 2018 Wiley Periodicals, Inc.

  2. Improved heating efficiency with High-Intensity Focused Ultrasound using a new ultrasound source excitation.

    PubMed

    Bigelow, Timothy A

    2009-01-01

    High-Intensity Focused Ultrasound (HIFU) is quickly becoming one of the best methods to thermally ablate tissue noninvasively. Unlike RF or Laser ablation, the tissue can be destroyed without inserting any probes into the body minimizing the risk of secondary complications such as infections. In this study, the heating efficiency of HIFU sources is improved by altering the excitation of the ultrasound source to take advantage of nonlinear propagation. For ultrasound, the phase velocity of the ultrasound wave depends on the amplitude of the wave resulting in the generation of higher harmonics. These higher harmonics are more efficiently converted into heat in the body due to the frequency dependence of the ultrasound absorption in tissue. In our study, the generation of the higher harmonics by nonlinear propagation is enhanced by transmitting an ultrasound wave with both the fundamental and a higher harmonic component included. Computer simulations demonstrated up to a 300% increase in temperature increase compared to transmitting at only the fundamental for the same acoustic power transmitted by the source.

  3. High-Accuracy Ultrasound Contrast Agent Detection Method for Diagnostic Ultrasound Imaging Systems.

    PubMed

    Ito, Koichi; Noro, Kazumasa; Yanagisawa, Yukari; Sakamoto, Maya; Mori, Shiro; Shiga, Kiyoto; Kodama, Tetsuya; Aoki, Takafumi

    2015-12-01

    An accurate method for detecting contrast agents using diagnostic ultrasound imaging systems is proposed. Contrast agents, such as microbubbles, passing through a blood vessel during ultrasound imaging are detected as blinking signals in the temporal axis, because their intensity value is constantly in motion. Ultrasound contrast agents are detected by evaluating the intensity variation of a pixel in the temporal axis. Conventional methods are based on simple subtraction of ultrasound images to detect ultrasound contrast agents. Even if the subject moves only slightly, a conventional detection method will introduce significant error. In contrast, the proposed technique employs spatiotemporal analysis of the pixel intensity variation over several frames. Experiments visualizing blood vessels in the mouse tail illustrated that the proposed method performs efficiently compared with conventional approaches. We also report that the new technique is useful for observing temporal changes in microvessel density in subiliac lymph nodes containing tumors. The results are compared with those of contrast-enhanced computed tomography. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Effect of high intensity focused ultrasound (HIFU) in conjunction with a nanomedicines-microbubble complex for enhanced drug delivery.

    PubMed

    Han, Hyounkoo; Lee, Hohyeon; Kim, Kwangmeyung; Kim, Hyuncheol

    2017-11-28

    Although nanomedicines have been intensively investigated for cancer therapy in the past, poor accumulation of nanomedicines in tumor sites remains a serious problem. Therefore, a novel drug delivery system is required to enhance accumulation and penetration of nanomedicines at the tumor site. Recently, high-intensity focused ultrasound (HIFU) has been highlighted as a non-invasive therapeutic modality, and showed enhanced therapeutic efficacy in combination with nanomedicines. Cavitation effect induced by the combination of HIFU and microbubbles results in transiently enhanced cell membrane permeability, facilitating improved drug delivery efficiency into tumor sites. Therefore, we introduce the acoustic cavitation and thermal/mechanical effects of HIFU in conjunction with microbubble to overcome the limitation of conventional drug delivery. The cavitation effect maximized by the strong acoustic energy of HIFU induced the preferential accumulation of nanomedicine locally released from the nanomedicines-microbubble complex in the tumor. In addition, the mechanical effect of HIFU allowed the accumulated nanomedicines to penetrate into deeper tumor region. The preferential accumulation and deeper penetration of nanomedicines by HIFU showed enhanced therapeutic efficacy, compared to low frequency ultrasound (US). These overall results demonstrate that the strategy combined nanomedicines-microbubble complex with HIFU is a promising tools for cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Systemic thrombolysis of portal vein thrombosis in cirrhotic patients: a pilot study.

    PubMed

    De Santis, Adriano; Moscatelli, Rosanna; Catalano, Carlo; Iannetti, Antonio; Gigliotti, Francesca; Cristofari, Francesca; Trapani, Silvia; Attili, Adolfo F

    2010-06-01

    Portal vein thrombosis is a frequent complication in liver cirrhosis. Encouraging reports of systemic thrombolysis in non-cirrhotic patients suffering from acute portal vein thrombosis led us to start a pilot study on the efficacy and safety of systemic low dose recombinant tissue plasminogen activator (Actilyse, Boheringer Ingelheim, Florence, Italy). Nine cirrhotic patients (6 males and 3 females) with recent portal vein thrombosis were enrolled. Exclusion criteria were portal cavernomatosis, recent (30 days) surgery, active bleeding, hepatocellular carcinoma and cancer in other sites. All cases were treated for a maximum of 7 days by continuous i.v. infusion of 0.25mg/kg/die of r-tPA plus subcutaneous low molecular weight heparin. Efficacy was evaluated by colour doppler sonography monitoring and confirmed by contrast enhanced computerized tomography. The combined r-tPA/LMWH treatment was well tolerated without clinically significant side effects. Complete resolution of thrombosis occurred in 4 cases, partial regression in 4 and none in 1. Retreatment of a complete recurrence in 1 patient was successful. Variceal pressure dropped from 30.7+/-4.5 mmHg to 21.2+/-6.6 mmHg (p=0.012). Our preliminary data demonstrate that thrombolytic treatment of recent portal vein thrombosis with i.v. r-tPA and LMWH in patients with cirrhosis appears to be safe and effective and can significantly reduce pressure in oesophageal varices. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  6. Improved mechanical properties of retorted carrots by ultrasonic pre-treatments.

    PubMed

    Day, Li; Xu, Mi; Øiseth, Sofia K; Mawson, Raymond

    2012-05-01

    The use of ultrasound pre-processing treatment, compared to blanching, to enhance mechanical properties of non-starchy cell wall materials was investigated using carrot as an example. The mechanical properties of carrot tissues were measured by compression and tensile testing after the pre-processing treatment prior to and after retorting. Carrot samples ultrasound treated for 10 min at 60 °C provided a higher mechanical strength (P<0.05) to the cell wall structure than blanching for the same time period. With the addition of 0.5% CaCl(2) in the pre-treatment solution, both blanching and ultrasound treatment showed synergistic effect on enhancing the mechanical properties of retorted carrot pieces. At a relatively short treatment time (10 min at 60 °C) with the use of 0.5% CaCl(2), ultrasound treatment achieved similar enhancement to the mechanical strength of retorted carrots to blanching for a much longer time period (i.e. 40 min). The mechanism involved appears to be related to the stress responses present in all living plant matter. However, there is a need to clarify the relative importance of the potential stress mechanisms in order to get a better understanding of the processing conditions likely to be most effective. The amount of ultrasound treatment required is likely to involve low treatment intensities and there are indications from the structural characterisation and mechanical property analyses that the plant cell wall tissues were more elastic than that accomplished using low temperature long time blanching. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  7. Ultrasound assisted intensification of enzyme activity and its properties: a mini-review.

    PubMed

    Nadar, Shamraja S; Rathod, Virendra K

    2017-08-22

    Over the last decade, ultrasound technique has emerged as the potential technology which shows large applications in food and biotechnology processes. Earlier, ultrasound has been employed as a method of enzyme inactivation but recently, it has been found that ultrasound does not inactivate all enzymes, particularly, under mild conditions. It has been shown that the use of ultrasonic treatment at appropriate frequencies and intensity levels can lead to enhanced enzyme activity due to favourable conformational changes in protein molecules without altering its structural integrity. The present review article gives an overview of influence of ultrasound irradiation parameters (intensity, duty cycle and frequency) and enzyme related factors (enzyme concentration, temperature and pH) on the catalytic activity of enzyme during ultrasound treatment. Also, it includes the effect of ultrasound on thermal kinetic parameters and Michaelis-Menten kinetic parameters (k m and V max ) of enzymes. Further, in this review, the physical and chemical effects of ultrasound on enzyme have been correlated with thermodynamic parameters (enthalpy and entropy). Various techniques used for investigating the conformation changes in enzyme after sonication have been highlighted. At the end, different techniques of immobilization for ultrasound treated enzyme have been summarized.

  8. Supercritical carbon dioxide extraction of capsaicinoids from malagueta pepper (Capsicum frutescens L.) assisted by ultrasound.

    PubMed

    Santos, Philipe; Aguiar, Ana C; Barbero, Gerardo F; Rezende, Camila A; Martínez, Julian

    2015-01-01

    Extracts from malagueta pepper (Capsicum frutescens L.) were obtained using supercritical fluid extraction (SFE) assisted by ultrasound, with carbon dioxide as solvent at 15MPa and 40°C. The SFE global yield increased up to 77% when ultrasound waves were applied, and the best condition of ultrasound-assisted extraction was ultrasound power of 360W applied during 60min. Four capsaicinoids were identified in the extracts and quantified by high performance liquid chromatography. The use of ultrasonic waves did not influence significantly the capsaicinoid profiles and the phenolic content of the extracts. However, ultrasound has enhanced the SFE rate. A model based on the broken and intact cell concept was adequate to represent the extraction kinetics and estimate the mass transfer coefficients, which were increased with ultrasound. Images obtained by field emission scanning electron microscopy showed that the action of ultrasonic waves did not cause cracks on the cell wall surface. On the other hand, ultrasound promoted disturbances in the vegetable matrix, leading to the release of extractable material on the solid surface. The effects of ultrasound were more significant on SFE from larger solid particles. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Color-coded perfusion analysis of CEUS for pre-interventional diagnosis of microvascularisation in cases of vascular malformations.

    PubMed

    Teusch, V I; Wohlgemuth, W A; Piehler, A P; Jung, E M

    2014-01-01

    Aim of our pilot study was the application of a contrast-enhanced color-coded ultrasound perfusion analysis in patients with vascular malformations to quantify microcirculatory alterations. 28 patients (16 female, 12 male, mean age 24.9 years) with high flow (n = 6) or slow-flow (n = 22) malformations were analyzed before intervention. An experienced examiner performed a color-coded Doppler sonography (CCDS) and a Power Doppler as well as a contrast-enhanced ultrasound after intravenous bolus injection of 1 - 2.4 ml of a second-generation ultrasound contrast medium (SonoVue®, Bracco, Milan). The contrast-enhanced examination was documented as a cine sequence over 60 s. The quantitative analysis based on color-coded contrast-enhanced ultrasound (CEUS) images included percentage peak enhancement (%peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT). No side effects occurred after intravenous contrast injection. The mean %peak in arteriovenous malformations was almost twice as high as in slow-flow-malformations. The area under the curve was 4 times higher in arteriovenous malformations compared to the mean value of other malformations. The mean transit time was 1.4 times higher in high-flow-malformations compared to slow-flow-malformations. There was no difference regarding the time to peak between the different malformation types. The comparison between all vascular malformation and surrounding tissue showed statistically significant differences for all analyzed data (%peak, TTP, AUC, MTT; p < 0.01). High-flow and slow-flow vascular malformations had statistically significant differences in %peak (p < 0.01), AUC analysis (p < 0.01), and MTT (p < 0.05). Color-coded perfusion analysis of CEUS seems to be a promising technique for the dynamic assessment of microvasculature in vascular malformations.

  10. Hilar biliary neurofibroma without neurofibromatosis: case report with contrast-enhanced ultrasound findings.

    PubMed

    Guo, Huan-Ling; Chen, Li-da; Wang, Zhu; Huang, Yang; Liu, Jin-Ya; Shan, Quan-Yuan; Xie, Xiao-Yan; Lu, Ming-de; Wang, Wei

    2016-10-01

    Solitary neurofibroma located in the hilum of the liver is extremely rare, particularly without neurofibromatosis. We herein report a case of hilar biliary neurofibroma without signs of von Recklinghausen's disease. A 36-year-old man was admitted to our department with progressive jaundice. The case was diagnosed as hilar cholangiocarcinoma based on preoperative imaging. The patient consequently received a Roux-en-Y hepaticojejunostomy and was confirmed with neurofibroma pathologically. This is the first reported imaging finding of hilar biliary neurofibroma using contrast-enhanced ultrasound, emphasizing the differential diagnosis of biliary tumors.

  11. Ultrasound beam steering of oxygen nanobubbles for enhanced bladder cancer therapy.

    PubMed

    Bhandari, Pushpak; Novikova, Gloriia; Goergen, Craig J; Irudayaraj, Joseph

    2018-02-15

    New intravesical treatment approaches for bladder cancer are needed as currently approved treatments show several side effects and high tumor recurrence rate. Our study used MB49 murine urothelial carcinoma model to evaluate oxygen encapsulated cellulosic nanobubbles as a novel agent for imaging and ultrasound guided drug delivery. In this study, we show that oxygen nanobubbles (ONB) can be propelled (up to 40 mm/s) and precisely guided in vivo to the tumor by an ultrasound beam. Nanobubble velocity can be controlled by altering the power of the ultrasound Doppler beam, while nanobubble direction can be adjusted to different desired angles by altering the angle of the beam. Precise ultrasound beam steering of oxygen nanobubbles was shown to enhance the efficacy of mitomycin-C, resulting in significantly lower tumor progression rates while using a 50% lower concentration of chemotherapeutic drug. Further, dark field imaging was utilized to visualize and quantify the ONB ex vivo. ONBs were found to localize up to 500 µm inside the tumor using beam steering. These results demonstrate the potential of an oxygen nanobubble drug encapsulated system to become a promising strategy for targeted drug delivery because of its multimodal (imaging and oxygen delivery) and multifunctional (targeting and hypoxia programming) properties.

  12. Theranostic Oxygen Delivery Using Ultrasound and Microbubbles

    PubMed Central

    Kwan, James J.; Kaya, Mehmet; Borden, Mark A.; Dayton, Paul A.

    2012-01-01

    Means to overcome tumor hypoxia have been the subject of clinical investigations since the 1960's; however these studies have yet to find a treatment which is widely accepted. It has been known for nearly a century that hypoxic cells are more resistant to radiotherapy than aerobic cells, and tumor hypoxia is a major factor leading to the resistance of tumors to radiation treatment as well as several cytotoxic agents. In this manuscript, the application of ultrasound combined with oxygen-carrier microbubbles is demonstrated as a method to locally increase dissolved oxygen. Microbubbles can also be imaged by ultrasound, thus providing the opportunity for image-guided oxygen delivery. Simulations of gas diffusion and microbubble gas exchange show that small amounts (down to 5 vol%) of a low-solubility osmotic gas can substantially increase microbubble persistence and therefore production rates and stability of oxygen-carrier microbubbles. Simulations also indicate that the lipid shell can be engineered with long-chain lipids to increase oxygen payload during in vivo transit. Experimental results demonstrate that the application of ultrasound to destroy the microbubbles significantly enhances the local oxygen release. We propose this technology as an application for ultrasound image-guided release of oxygen directly to hypoxic tissue, such as tumor sites to enhance radiotherapy. PMID:23382774

  13. The Application of Ultrasound in 3D Bio-Printing.

    PubMed

    Zhou, Yufeng

    2016-05-05

    Three-dimensional (3D) bioprinting is an emerging and promising technology in tissue engineering to construct tissues and organs for implantation. Alignment of self-assembly cell spheroids that are used as bioink could be very accurate after droplet ejection from bioprinter. Complex and heterogeneous tissue structures could be built using rapid additive manufacture technology and multiple cell lines. Effective vascularization in the engineered tissue samples is critical in any clinical application. In this review paper, the current technologies and processing steps (such as printing, preparation of bioink, cross-linking, tissue fusion and maturation) in 3D bio-printing are introduced, and their specifications are compared with each other. In addition, the application of ultrasound in this novel field is also introduced. Cells experience acoustic radiation force in ultrasound standing wave field (USWF) and then accumulate at the pressure node at low acoustic pressure. Formation of cell spheroids by this method is within minutes with uniform size and homogeneous cell distribution. Neovessel formation from USWF-induced endothelial cell spheroids is significant. Low-intensity ultrasound could enhance the proliferation and differentiation of stem cells. Its use is at low cost and compatible with current bioreactor. In summary, ultrasound application in 3D bio-printing may solve some challenges and enhance the outcomes.

  14. Dynamic Behavior of Microbubbles during Long Ultrasound Tone-Burst Excitation: Mechanistic Insights into Ultrasound-Microbubble Mediated Therapeutics Using High-Speed Imaging and Cavitation Detection.

    PubMed

    Chen, Xucai; Wang, Jianjun; Pacella, John J; Villanueva, Flordeliza S

    2016-02-01

    Ultrasound (US)-microbubble (MB)-mediated therapies have been found to restore perfusion and enhance drug/gene delivery. On the presumption that MBs do not persist during long US exposure under high acoustic pressures, most schemes use short US pulses when a high US pressure is employed. However, we recently observed an enhanced thrombolytic effect using long US pulses at high acoustic pressures. Therefore, we explored the fate of MBs during long tone-burst exposures (5 ms) at various acoustic pressures and MB concentrations via direct high-speed optical observation and passive cavitation detection. MBs first underwent stable or inertial cavitation depending on the acoustic pressure and then formed gas-filled clusters that continued to oscillate, break up and form new clusters. Cavitation detection confirmed continued, albeit diminishing, acoustic activity throughout the 5-ms US excitation. These data suggest that persisting cavitation activity during long tone bursts may confer additional therapeutic effects. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Preparation and characterization of a novel silicon-modified nanobubble

    PubMed Central

    Li, Maotong; Zhou, Meijun; Li, Fei; Huang, Xiuxian; Pan, Min; Xue, Li

    2017-01-01

    Nanobubbles (NBs) opened a new field of ultrasound imaging. There is still no practical method to control the diameter of bubbles. In this study, we developed a new method to control the size by incorporating of silicon hybrid lipids into the bubble membrane. The range of particle size of resulting NBs is between 523.02 ± 46.45 to 857.18 ± 82.90, smaller than the conventional microbubbles. The size of resulting NBs increased with the decrease in amount of silicon hybrid lipids, indicating the diameter of NBs can be regulated through modulating the ratio of silicon hybrid lipids in the bubble shell. Typical harmonic signals could be detected. The in vitro and in vivo ultrasound imaging experiments demonstrated these silicon-modified NBs had significantly improved ultrasound contrast enhancement abilities. Cytotoxicity assays revealed that these NBs had no obvious cytotoxicity to the 293 cell line at the tested bubble concentration. Our results showed that the novel NBs could use as nanoscale ultrasound contrast agents, providing the foundation for NBs in future applications including contrast-enhanced imaging and drug/gene delivery. PMID:28557995

  16. Optimization of ultrasound assisted extraction of bioactive components from brown seaweed Ascophyllum nodosum using response surface methodology.

    PubMed

    Kadam, Shekhar U; Tiwari, Brijesh K; Smyth, Thomas J; O'Donnell, Colm P

    2015-03-01

    The objective of this study was to investigate the effect of key extraction parameters of extraction time (5-25 min), acid concentration (0-0.06 M HCl) and ultrasound amplitude (22.8-114 μm) on yields of bioactive compounds (total phenolics, fucose and uronic acid) from Ascophyllumnodosum. Response surface methodology was employed to optimize the extraction variables for bioactive compounds' yield. A second order polynomial model was fitted well to the extraction experimental data with (R(2)>0.79). Extraction yields of 143.12 mgGAE/gdb, 87.06 mg/gdb and 128.54 mg/gdb were obtained for total phenolics, fucose and uronic acid respectively at optimized extraction conditions of extraction time (25 min), acid concentration (0.03 M HCl) and ultrasonic amplitude (114 μm). Mass spectroscopy analysis of extracts show that ultrasound enhances the extraction of high molecular weight phenolic compounds from A. nodosum. This study demonstrates that ultrasound assisted extraction (UAE) can be employed to enhance extraction of bioactive compounds from seaweed. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Grade III ischemia on presentation with acute myocardial infarction predicts rapid progression of necrosis and less myocardial salvage with thrombolysis.

    PubMed

    Birnbaum, Yochai; Mahaffey, Kenneth W; Criger, Douglas A; Gates, Kathy B; Barbash, Gabriel I; Barbagelata, Alejandro; Clemmensen, Peter; Sgarbossa, Elena B; Gibbons, Raymond J; Rahman, M Atiar; Califf, Robert M; Granger, Chistopher B; Wagner, Galen S

    2002-01-01

    We assessed the relation between baseline electrocardiographic ischemia grades and initial myocardial area at risk (AR) and final infarct size (IS) in 49 patients who had undergone (99m)Tc sestamibi single-photon emission computed tomography before and 6 +/- 1 days after thrombolysis. Patients were classed as having grade III ischemia (ST segment elevation with terminal QRS distortion, n = 19) or grade II ischemia (ST elevation but no terminal QRS distortion, n = 30). We compared AR and IS by baseline ischemia grade and treatment (adenosine vs. placebo) and assessed relations of infarction index (IS/AR ratio x100) to time to thrombolysis, baseline ischemia grade, and adenosine therapy. Time to thrombolysis was similar for grade II and grade III. For placebo- treated patients, the median AR did not differ significantly between grade II (38%) and grade III patients (46%, p = 0.47), nor did median IS (16 vs. 40%, p = 0.096), but the median infarction index was 66 vs. 90% (p = 0.006). For adenosine-treated patients, median AR (21 vs. 26%, p = 0.44), median IS (5 vs. 17%, p = 0.15), and their ratio (31 vs. 67%, p = 0.23) did not differ significantly between grade II and grade III patients. The infarction index independently related to grade III ischemia (p = 0.0121) and adenosine therapy (p = 0.045). Infarct size related to baseline ischemia grade and was reduced by adenosine treatment. Necrosis progressed slowlier with baseline grade II versus III ischemia, which could offer more time for myocardial salvage with reperfusion. Copyright 2002 S. Karger AG, Basel

  18. Thrombectomy in patients ineligible for iv tPA (THRILL).

    PubMed

    Bendszus, Martin; Thomalla, Götz; Knauth, Michael; Hacke, Werner; Bonekamp, Susanne; Fiehler, Jens

    2015-08-01

    A relevant proportion of patients with acute ischemic stroke are ineligible for intravenous thrombolysis with recombinant tissue plasminogen activator. Mechanical thrombectomy offers a treatment alternative for these patients; however, only few data are available on its safety and efficacy. The aim of this study was to compare safety and efficacy of stent retrievers as device class with best medical care alone in acute stroke patients with large intracranial vessel occlusion in the anterior circulation who are not eligible for intravenous thrombolysis with recombinant tissue plasminogen activator up to eight-hours of symptom onset. 'Thrombectomy in patients ineligible for iv tPA' is a prospective, open-label, blinded end-point, binational (Germany and Austria), two-arm, randomized, controlled, post-market study. Primary end-point is the modified Rankin Score shift analysis 90 days (±14) after stroke. Secondary end-points are excellent neurological outcomes (modified Rankin Score ≤ 1), good neurological outcomes (modified Rankin Score ≤ 2 or National Institutes of Health Stroke Scale improvement ≥ 10), difference between predicted infarct volume and actual core infarct volume (computed tomography or magnetic resonance imaging) at 30 (±6) h post-ictus, successful recanalization (thrombolysis in cerebral infarction score 2b or 3), functional health status 90 (±14) days after stroke (European Quality of Life-5 Dimensions) as well as common safety end-points (adverse event, serious adverse event, symptomatic intracranial haemorrhage at 30 (±6) h, death, or dependency). Whether mechanical thrombectomy in patients with acute ischemic stroke who are not eligible for intravenous thrombolysis with recombinant tissue plasminogen activator improves clinical outcomes is unclear. 'Thrombectomy in patients ineligible for iv tPA' may change clinical practice by providing evidence of an effective and safe treatment for such patients. © 2015 World Stroke Organization.

  19. Pre-hospital Delay as Determinant of Ischemic Stroke Outcome in an Italian Cohort of Patients Not Receiving Thrombolysis.

    PubMed

    Denti, Licia; Artoni, Andrea; Scoditti, Umberto; Gatti, Elisa; Bussolati, Chiara; Ceda, Gian Paolo

    2016-06-01

    Pre-hospital delay in acute stroke is critical to the administration of thrombolysis and affects patients' clinical outcome. In this study, the impact of pre-hospital delay on the outcome of ischemic stroke was investigated in an Italian cohort of patients who did not receive thrombolysis. Data from a cohort of 1847 patients, suffering from first-ever ischemic stroke and referred to an in-hospital clinical pathway were analyzed retrospectively. The relationship between pre-hospital delay and 1-month mortality was assessed with adjustment for demographics, premorbid disability, and stroke severity, which was graded according to the Scandinavian Stroke Scale, with higher scores indicating less severity. Five hundred and twelve patients (27.7%) arrived at hospital within 2 hours of symptom onset. A significant correlation was found between early arrival and a reduced risk of 1-month mortality (hazard ratio .65; 95% confidence interval .48-.89; P = .02). There was a significant interaction (P = .01) between pre-hospital delay and the neurological score on mortality in the multivariate model, and the survival advantage of early admission was significant only for patients with scores on the Scandinavian Stroke Scale less than 18 (hazard ratio .54; 95% confidence interval .34-.85; P = .008). Our study suggests that reducing pre-hospital delay can increase the probability of survival in patients with ischemic stroke, especially those who are most severely affected. Even if the patients cannot benefit from thrombolysis, survival rates can be increased provided that they are managed according to standardized care processes. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  20. First experiences with a new device for mechanical thrombectomy in acute basilar artery occlusion.

    PubMed

    Roth, C; Mielke, A; Siekmann, R; Ferbert, A

    2011-01-01

    The aim of this study was to evaluate our first results using a new device for mechanical thrombectomy in patients with acute basilar artery occlusion. Between May 2009 and September 2010 a new device for aspiration thrombectomy (The Penumbra System™; Penumbra Inc., Alameda, Calif., USA) was used in 12 patients with acute basilar artery occlusion. We performed a retrospective review of these patients' medical records. One patient received endovascular treatment without intravenous (IV) thrombolysis because of infarction on the initial CT scan. Eleven of 12 patients received IV thrombolysis with rtPA followed by endovascular thrombectomy according to a bridging concept. After thrombolysis, the basilar artery was patent in 1 patient (9%), partially recanalized in 3 (27%) and still occluded in 7 (64%). The endovascular device could not access in 2 patients (17%). Among the remaining 10 patients, the patency rate after thrombectomy was 100%. The overall patency rate after treatment was 9 of 12 (75%) at the time of discharge. National Institute of Health Stroke Scale improved from a median of 27 to a median of 18 after treatment. Four patients died (33%). The survivors had a mean modified Rankin Scale before discharge of 2.3 (range 0-4). A bridging therapy with the combination of IV thrombolysis with recombinant tissue plasminogen activator and continuous aspiration thrombectomy seems to be a promising therapy strategy for acute basilar artery occlusion. Furthermore, our results confirm the advantage of the additional use of this new thrombectomy device, working with thrombus aspiration, with a satisfactory patency rate and a good clinical outcome. Copyright © 2011 S. Karger AG, Basel.

Top