Sample records for ultrasound examination showed

  1. Comparison of barium swallow and ultrasound in diagnosis of gastro-oesophageal reflux in children.

    PubMed Central

    Naik, D R; Bolia, A; Moore, D J

    1985-01-01

    Fifty one infants and older children with suspected gastro-oesophageal reflux entered a study comparing the diagnostic accuracy of a standard barium swallow examination with that of ultrasound scanning. All children were examined by both techniques. In 40 cases there was unequivocal agreement between the examinations. Of the remaining patients, four had definite reflux by ultrasonic criteria but showed no evidence of reflux on barium swallow examination, four had positive findings on ultrasound but showed only minimal reflux on barium swallow, and one showed minimal reflux on ultrasound but had a negative barium meal result. In two children the ultrasound study was inconclusive. Ultrasound has an important role in the diagnosis and follow up of patients under the age of 5 years with gastro-oesophageal reflux. Images FIG 1 FIG 2 PMID:3924317

  2. Disparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening.

    PubMed

    Kyung, Bong Soo; Lee, Soon Hyuck; Jeong, Woong Kyo; Park, Si Young

    2016-06-01

    For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening strategy, we assessed the agreement among the methods; clinical examination by an experienced pediatric orthopedic surgeon, sonographic morphology, and sonographic stability. From January 2004 to June 2009, a single experienced pediatric orthopedic surgeon performed clinical hip screenings for 2,686 infants in the neonatal unit and 43 infants who were referred due to impressions of hip dysplasia before 3 months of age. Among them, 156 clinically unstable or high-risk babies selectively received bilateral hip ultrasound examinations performed by the same surgeon using the modified Graf method. The results were analyzed statistically to detect any correlations between the clinical and sonographic findings. Although a single experienced orthopedic surgeon conducted all examinations, we detected only a limited relationship between the results of clinical and ultrasound examinations. Ninety-three percent of the clinically subluxatable hips were normal or immature based on static ultrasound examination, and 74% of dislocating hips and 67% of limited abduction hips presented with the morphology below Graf IIa. A total of 80% of clinically subluxatable, 42% of dislocating and 67% of limited abduction hips appeared stable or exhibited minor instability on dynamic ultrasound examination. About 7% of clinically normal hips were abnormal upon ultrasound examination; 5% showed major instability and 3% showed dysplasia above Graf IIc. Clinical stability had small coefficients between ultrasound examinations; 0.39 for sonographic stability and 0.37 for sonographic morphology. Between sonographic stability and morphology, although 71% of hips with major instability showed normal or immature morphology according to static ultrasound examination, the coefficient was as high as 0.64. Discrepancies between clinical and ultrasound examinations were present even if almost all of the exams were performed by a single experienced pediatric orthopedic surgeon. In relation to screening for DDH, it is recommended that both sonographic morphology and stability be checked in addition to clinical examination.

  3. Effects of ultrasound implementation on physical examination learning and teaching during the first year of medical education.

    PubMed

    Dinh, Vi Am; Frederick, Jon; Bartos, Rebekah; Shankel, Tamara M; Werner, Leonard

    2015-01-01

    Increasing emphasis has been placed on point-of-care ultrasound in medical school. The overall effects of ultrasound curriculum implementation on the traditional physical examination skills of medical students are still unknown. We studied the effects on the Objective Standardized Clinical Examination (OSCE) scores of year 1 medical students before and after ultrasound curriculum implementation. An ultrasound curriculum was incorporated into the physical diagnosis course for year 1 medical students in the 2012-2013 academic year. We performed a prospective observational study comparing traditional OSCE scores of year 1 medical students exposed to the ultrasound curriculum (post-ultrasound) versus historic year 1 medical student controls (pre-ultrasound) with no ultrasound exposure. Questionnaire data were also obtained from year 1 medical students and physical diagnosis faculty to assess attitudes toward ultrasound implementation. The final overall OSCE scores were graded with a 5-point Likert-type scale from unsatisfactory to outstanding. There was a significant increase in outstanding scores in the post-ultrasound compared to the pre-ultrasound group (27.0% versus 10.9%; P< .001). The post-ultrasound group had significantly (P< .05) increased first-time pass rates on blood pressure measurements, the abdominal examination, and professionalism. Student and physical diagnosis faculty questionnaire data showed an overall positive response, with most agreeing or strongly agreeing that ultrasound should be included in the future year 1 medical student curriculum. Ultrasound implementation into a physical diagnosis curriculum for year 1 medical students is feasible and may improve their overall traditional physical examination skills. © 2015 by the American Institute of Ultrasound in Medicine.

  4. Value of mammography and breast ultrasound in male patients with nipple discharge.

    PubMed

    Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor

    2013-03-01

    To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Core review: physician-performed ultrasound: the time has come for routine use in acute care medicine.

    PubMed

    Royse, Colin F; Canty, David J; Faris, John; Haji, Darsim L; Veltman, Michael; Royse, Alistair

    2012-11-01

    The use of ultrasound in the acute care specialties of anesthesiology, intensive care, emergency medicine, and surgery has evolved from discrete, office-based echocardiographic examinations to the real-time or point-of-care clinical assessment and interventions. "Goal-focused" transthoracic echocardiography is a limited scope (as compared with comprehensive examination) echocardiographic examination, performed by the treating clinician in acute care medical practice, and is aimed at addressing specific clinical concerns. In the future, the practice of surface ultrasound will be integrated into the everyday clinical practice as ultrasound-assisted examination and ultrasound-guided procedures. This evolution should start at the medical student level and be reinforced throughout specialist training. The key to making ultrasound available to every physician is through education programs designed to facilitate uptake, rather than to prevent access to this technology and education by specialist craft groups. There is evidence that diagnosis is improved with ultrasound examination, yet data showing change in management and improvement in patient outcome are few and an important area for future research.

  6. Study on text mining algorithm for ultrasound examination of chronic liver diseases based on spectral clustering

    NASA Astrophysics Data System (ADS)

    Chang, Bingguo; Chen, Xiaofei

    2018-05-01

    Ultrasonography is an important examination for the diagnosis of chronic liver disease. The doctor gives the liver indicators and suggests the patient's condition according to the description of ultrasound report. With the rapid increase in the amount of data of ultrasound report, the workload of professional physician to manually distinguish ultrasound results significantly increases. In this paper, we use the spectral clustering method to cluster analysis of the description of the ultrasound report, and automatically generate the ultrasonic diagnostic diagnosis by machine learning. 110 groups ultrasound examination report of chronic liver disease were selected as test samples in this experiment, and the results were validated by spectral clustering and compared with k-means clustering algorithm. The results show that the accuracy of spectral clustering is 92.73%, which is higher than that of k-means clustering algorithm, which provides a powerful ultrasound-assisted diagnosis for patients with chronic liver disease.

  7. Parental expectations, experiences and reactions, sense of coherence and grade of anxiety related to routine ultrasound examination with normal findings during pregnancy.

    PubMed

    Ekelin, M; Crang Svalenius, E; Larsson, A-K; Nyberg, P; Marsál, K; Dykes, A-K

    2009-10-01

    To investigate parents' expectations, experiences and reactions, sense of coherence and anxiety before and after a second-trimester routine ultrasound examination, with normal findings. Before and after ultrasound questionnaires including the scales parents' expectations, experiences and reactions to routine ultrasound examination (PEER-U state of mind index), sense of coherence (SOC) and state and trait anxiety inventory (STAI), were sent to a 1-year cohort of women and their partners. Replies received were 2183. Both parents had significantly less worried state of mind (PEER-U) after the examination than before. Women had a lower grade of state anxiety after than before, but for men there was no significant change. Before the ultrasound, women had a higher degree of worried state of mind, as well as a higher grade of state and trait anxiety and a lower sense of coherence, than men. The women showed a greater reduction in worried state of mind than the men after the ultrasound examination. There were no significant differences in sense of coherence before and after ultrasound. Women and men are affected in their psychological well-being in relation to a routine ultrasound examination, but their sense of coherence remains stable.

  8. Radiographer-performed abdominal and pelvic ultrasound: its value in a urology out-patient clinic.

    PubMed

    Nargund, V H; Lomas, K; Sapherson, D A; Flannigan, G M; Stewart, P A

    1994-04-01

    To assess the efficacy of radiographer-performed ultrasound examination as a routine investigative procedure in a urological out-patient clinic. A total of 151 patients attending a District General Hospital Urological Out-patient Department underwent an ultrasound examination in the clinic. Diagnosis by ultrasound was achieved in 93% of patients. The remaining patients underwent further investigations. Two (1%) patients with normal scans had small bladder tumours. Subsequent intravenous urography in these individuals showed normal upper tracts. Abdominal and pelvic ultrasound examination performed in the urological out-patient clinic on unprepared patients was the only investigation necessary for evaluation of common problems such as non-specific urinary symptoms, recurrent urinary tract infections and bladder outlet obstruction.

  9. Electrophysiological examination and high frequency ultrasonography for diagnosis of radial nerve torsion and compression

    PubMed Central

    Shi, Miao; Qi, Hengtao; Ding, Hongyu; Chen, Feng; Xin, Zhaoqin; Zhao, Qinghua; Guan, Shibing; Shi, Hao

    2018-01-01

    Abstract This study aims to evaluate the value of electrophysiological examination and high frequency ultrasonography in the differential diagnosis of radial nerve torsion and radial nerve compression. Patients with radial nerve torsion (n = 14) and radial nerve compression (n = 14) were enrolled. The results of neurophysiological and high frequency ultrasonography were compared. Electrophysiological examination and high-frequency ultrasonography had a high diagnostic rate for both diseases with consistent results. Of the 28 patients, 23 were positive for electrophysiological examination, showing decreased amplitude and decreased conduction velocity of radial nerve; however, electrophysiological examination cannot distinguish torsion from compression. A total of 27 cases showed positive in ultrasound examinations among all 28 cases. On ultrasound images, the nerve was thinned at torsion site whereas thickened at the distal ends of torsion. The diameter and cross-sectional area of torsion or compression determined the nerve damage, and ultrasound could locate the nerve injury site and measure the length of the nerve. Electrophysiological examination and high-frequency ultrasonography can diagnose radial neuropathy, with electrophysiological examination reflecting the neurological function, and high-frequency ultrasound differentiating nerve torsion from compression. PMID:29480857

  10. Establishment of ultrasound as a diagnostic aid in the referral of patients with abdominal pain in an emergency department – a pilot study

    PubMed Central

    Poulsen, Liv la Cour; Bækgaard, Emilie Stokholm; Istre, Per Grosen; Schmidt, Thomas Andersen; Larsen, Torben

    2015-01-01

    Purpose Ultrasonography is a noninvasive, cheap, and fast way of assessing abdominal pain in an emergency department. Many physicians working in emergency departments do not have pre-existing ultrasound experience. The purpose of this study was to investigate the ability of first-year internship doctors to perform a reliable ultrasound examination on patients with abdominal pain in an emergency setting. Materials and methods This study took place in an emergency department in Denmark. Following a 1-day ultrasound introduction course, three doctors without prior ultrasound experience scanned 45 patients during a 2-month period. The applicability of the examinations was evaluated by subsequent control examination: computed tomography, operation, or ultrasound by a trained radiologist or gynecologist or, in cases where the patient was immediately discharged, by ultrasound image evaluation. Results In 14 out of 21 patients with a control examination, there was diagnostic agreement between the project ultrasound examination and the control. Image evaluation of all patients showed useful images of the gallbladder, kidneys, liver, abdominal aorta, and urinary bladder, but no useful images for either the pancreas or colon. Conclusion With only little formal training, it is possible for first-year internship doctors to correctly visualize some abdominal organs with ultrasonography. However, a longer study time frame, including more patients, and an ultrasound course specifically designed for the purpose of use in an emergency department, is needed to enhance the results. PMID:27147884

  11. [Real-time elastography in the diagnosis of prostate cancer: personal experience].

    PubMed

    Romagnoli, Andrea; Autieri, Gaspare; Centrella, Danilo; Gastaldi, Christian; Pedaci, Giuseppe; Rivolta, Lorenzo; Pozzi, Emilio; Anghileri, Alessio; Cerabino, Maurizio; Bianchi, Carlo Maria; Roggia, Alberto

    2010-01-01

    Prostate cancer is the most common cancer in men. In the future, a significant further increase in the incidence of prostate cancer is expected. The indication to perform a prostate biopsy is digital rectal examination suspicious for prostate cancer, total prostate specific antigen (PSA) value, free PSA/total PSA ratio, PSA density and PSA velocity, and an evidence of hypoechoic area at transrectal ultrasound scan. Unfortunately the specificity and sensibility are still poor. The aim of this retrospective study is to evaluate the specificity and sensibility of real time elastography versus ultrasound transrectal B-mode scan. We retrospectively evaluated 108 pts. having undergone TRUS-guided transrectal prostate biopsy (10 samples). The indication for biopsy is: digital rectal examination, total prostate specific antigen (PSA) value, PSA ratio, PSA density and PSA velocity suspicious for prostate cancer, and/or an evidence of hypoechoic area at transrectal ultrasound scan, and/or hard area at real-time elastography. The mean age of patients is 66.8 years, mean PSA 6.5 ng/mL, and mean ratio 16.5%. We compared the histopathological findings of needle prostate biopsies with the results of transrectal ultrasound and transrectal real-time elastography. 32/108 (29.6%) pts. were positive for prostate cancer (mean Gleason score 7.08), mean PSA 14 ng/mL and mean ratio 9.5%. Transrectal ultrasound scan shows a sensibility of 69% and specificity of 68%. Transrectal ultrasound scan shows a VPP of 51.4%. Transrectal ultrasound scan shows a VPN of 80.9%. Real-time elastography shows a sensibility of 56% and specificity of 85.7%. Real-time elastography shows a VPP of 60.1%. Real-time elastography shows a VPN of 83%. Elastography has a significantly higher specificity for the detection of prostate cancer than the conventionally used examinations including DRE and TRUS. It is a useful real-time diagnostic method because it is not invasive, and simultaneous evaluation is possible while performing TRUS.

  12. The role of abdominal ultrasound in the diagnosis of typhoid fever: an observational study.

    PubMed

    Younis, Saeed Nadhim

    2014-01-01

    To study the usefulness of abdominal ultrasound in the diagnosis of typhoid fever and to determine the common ultrasound findings early in the course of the disease. Abdominal ultrasound examination was performed within the first week of initiation of symptoms in 350 cases with clinical diagnosis of typhoid fever. Subsequent ultrasound follow-up examination was done 15 days later (beginning of the third week). All the patients proved to have positive Widal test and Sallmonella culture. The study was performed in Erbil-Iraq from the period January 1993 to October 2010. The following ultrasound findings were reported: hepatomegaly (31.4%), prominent intrahepatic bile ducts (64.85%), splenomegaly (100%), mesenteric lymphadenopathy (42.85%), bowel wall thickening (35.71%), acalculous cholecystitis (16.28%), perforations (1.14%), and ascites in (3.4%). The current study showed that the findings are typical enough to justify initiation of treatment for typhoid fever when serology is equivocal and culture is negative, and is fairly safe to say that normal ultrasound examination early in the course of febrile illness rules out typhoid fever. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography.

    PubMed

    Adams, Scott J; Burbridge, Brent E; Badea, Andreea; Langford, Leanne; Vergara, Vincent; Bryce, Rhonda; Bustamante, Luis; Mendez, Ivar M; Babyn, Paul S

    2017-08-01

    The study sought to assess the feasibility of performing adult abdominal examinations using a telerobotic ultrasound system in which radiologists or sonographers can control fine movements of a transducer and all ultrasound settings from a remote location. Eighteen patients prospectively underwent a conventional sonography examination (using EPIQ 5 [Philips] or LOGIQ E9 [GE Healthcare]) followed by a telerobotic sonography examination (using the MELODY System [AdEchoTech] and SonixTablet [BK Ultrasound]) according to a standardized abdominal imaging protocol. For telerobotic examinations, patients were scanned remotely by a sonographer 2.75 km away. Conventional examinations were read independently from telerobotic examinations. Image quality and acceptability to patients and sonographers was assessed. Ninety-two percent of organs visualized on conventional examinations were sufficiently visualized on telerobotic examinations. Five pathological findings were identified on both telerobotic and conventional examinations, 3 findings were identified using only conventional sonography, and 2 findings were identified using only telerobotic sonography. A paired sample t test showed no significant difference between the 2 modalities in measurements of the liver, spleen, and diameter of the proximal aorta; however, telerobotic assessments overestimated distal aorta and common bile duct diameters and underestimated kidney lengths (P values < .05). All patients responded that they would be willing to have another telerobotic examination. A telerobotic ultrasound system is feasible for performing abdominal ultrasound examinations at a distant location with minimal training and setup requirements and a moderate learning curve. Telerobotic sonography (robotic telesonography) may open up the possibility of remote ultrasound clinics for communities that lack skilled sonographers and radiologists, thereby improving access to care. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  14. Auscultation versus Point-of-care Ultrasound to Determine Endotracheal versus Bronchial Intubation: A Diagnostic Accuracy Study.

    PubMed

    Ramsingh, Davinder; Frank, Ethan; Haughton, Robert; Schilling, John; Gimenez, Kimberly M; Banh, Esther; Rinehart, Joseph; Cannesson, Maxime

    2016-05-01

    Unrecognized malposition of the endotracheal tube (ETT) can lead to severe complications in patients under general anesthesia. The focus of this double-blinded randomized study was to assess the accuracy of point-of-care ultrasound in verifying the correct position of the ETT and to compare it with the accuracy of auscultation. Forty-two adult patients requiring general anesthesia with ETT were consented. Patients were randomized to right main bronchus, left main bronchus, or tracheal intubation. After randomization, the ETT was placed via fiber-optic visualization. Next, the location of the ETT was assessed using auscultation by a separate blinded anesthesiologist, followed by an ultrasound performed by a third blinded anesthesiologist. Ultrasound examination included assessment of tracheal dilation via cuff inflation with air and evaluation of pleural lung sliding. Statistical analysis included sensitivity, specificity, positive predictive value, negative predictive value, and interobserver agreement for the ultrasound examination (95% CI). In differentiating tracheal versus bronchial intubations, auscultation showed a sensitivity of 66% (0.39 to 0.87) and a specificity of 59% (0.39 to 0.77), whereas ultrasound showed a sensitivity of 93% (0.66 to 0.99) and specificity of 96% (0.79 to 1). Identification of tracheal versus bronchial intubation was 62% (26 of 42) in the auscultation group and 95% (40 of 42) in the ultrasound group (P = 0.0005) (CI for difference, 0.15 to 0.52), and the McNemar comparison showed statistically significant improvement with ultrasound (P < 0.0001). Interobserver agreement of ultrasound findings was 100%. Assessment of trachea and pleura via point-of-care ultrasound is superior to auscultation in determining the location of ETT.

  15. Effects of low-frequency ultrasound on heterogenous deacetylation of chitin.

    PubMed

    Ngo, Thi Hoai Duong; Ngo, Dang Nghia

    2017-11-01

    The effects of low frequency ultrasound to the heterogeneous deacetylation of chitin from the shell of white shrimp (Penaeus vannamei) were examined. The deacetylation process was carried out in the range of NaOH concentrations from 35% to 65% (w/w) with and without the ultrasound in the frequency of 37kHz, RMS=300W. The chitosan obtained was characterized in the degree of deacetylation, solubility, FT-IR and X-ray diffraction. The results showed that the behaviors of the deacetylation in two cases, with and without ultrasound, were similar but the ultrasound enhanced the deacetylation rate and therefore reduced the time of the reaction to get the same degree of deacetylation. The role of ultrasound in the process showed more clearly in the low concentration of sodium hydroxide, below 45% (w/w). At the higher concentration of sodium hydroxide, the influence of ultrasound on facilitating deacetylation decreased significantly, however, ultrasound was still keeping on its improving effect on the solubility of the chitosan obtained. The data from FT-IR and X-ray diffraction did not show any considerable change in structure of both kinds of chitosan. This study showed the potential of using low frequency ultrasound in enhancing the deacetylation of chitin for reducing the chemical consumption. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Breast ultrasound in the management of gynecomastia in Peutz-Jeghers syndrome in monozygotic twins: two case reports.

    PubMed

    Di Grezia, Graziella; Romano, Tiziana; De Francesco, Francesco; Somma, Francesco; Rea, Gaetano; Grassi, Roberto; Gatta, Gianluca

    2014-12-18

    Peutz-Jeghers syndrome is an autosomal dominant disease with incomplete penetrance and variable expression caused by germline mutation of serine threonine kinase 11/liver kinase B1; it is characterized by hamartomatous polyps in the gastrointestinal tract, mucocutaneous melanin pigmentation, and increased predisposition to neoplasms. In Peutz-Jeghers syndrome, bilateral Sertoli cell testicular tumors cause endocrine manifestations including gynecomastia and feminization. This study aimed to assess the role of breast ultrasound in the evaluation of the effectiveness of an innovative surgical approach. This report presents a pair of European 9-year-old identical male twins with Peutz-Jeghers syndrome, bilateral prepubertal gynecomastia, and testicular multifocal calcifications. Both twins were treated with anastrozole for 2 years. After finishing treatment, both underwent subcutaneous mastectomy performed by the "modified" Webster technique. Breast examination and ultrasound were performed before and after the pharmacological and surgical treatment. A breast ultrasound scan before surgery showed bilateral gynecomastia in both patients. No solid nodular or cystic formations were present on either side. After pharmacological therapy and surgical glandular removal, a breast examination showed a significant reduction in breast volume; 1 year after surgery, a breast ultrasound scan of both patients showed a total absence of glandular parenchyma, with muscle planes well represented. Breast examination and ultrasound have proved to be a valid approach in the assessment of the treatment of prepubertal gynecomastia because they allow the efficacy of the pharmacological and surgical treatment to be evaluated in a multidisciplinary approach to one of the most frequent endocrine manifestations of Peutz-Jeghers syndrome.

  17. Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko

    2012-06-01

    Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Evaluation of chest ultrasound integrated teaching of respiratory system physiology to medical students.

    PubMed

    Paganini, Matteo; Bondì, Michela; Rubini, Alessandro

    2017-12-01

    Ultrasound imaging is a widely used diagnostic technique, whose integration in medical education is constantly growing. The aim of this study was to evaluate chest ultrasound usefulness in teaching respiratory system physiology, students' perception of chest ultrasound integration into a traditional lecture in human physiology, and short-term concept retention. A lecture about respiratory physiology was integrated with ultrasound and delivered to third-year medical students. It included basic concepts of ultrasound imaging and the physiology of four anatomic sectors of the body of a male volunteer, shown with a portable ultrasound device (pleural sliding, diaphragmatic movement, inferior vena cava diameter variations, cardiac movements). Students' perceptions of the integrated lecture were assessed, and attendance recorded. After 4 mo, four multiple-choice questions about respiratory physiology were administered during the normal human physiology examinations, and the results of students who attended the lesson and those of who did not were compared. One hundred thirty-four students attended the lecture. Most of them showed encouragement for the study of the subject and considered the ultrasound integrated lecture more interesting than a traditional one and pertinent to the syllabus. Exposed students achieved a better score at the examination and committed less errors than did nonexposed students. The chest ultrasound integrated lecture was appreciated by students. A possible association between the exposure to the lecture and short-term concept retention is shown by better performances of the exposed cohort at the examination. A systematic introduction of ultrasound into physiology traditional teaching will be promoted by the Ultrasound-Based Medical Education movement. Copyright © 2017 the American Physiological Society.

  19. Use of ultrasound imaging for the diagnosis of abnormal uterine bleeding in the bonnet macaque ( Macaca radiata).

    PubMed

    Chaudhari, Uddhav K; Imran, M; Manjramkar, Dhananjay D; Metkari, Siddhanath M; Sable, Nilesh P; Gavhane, Dnyaneshwar S; Katkam, Rajendra R; Sachdeva, Geetanjali; Thakur, Meenakshi H; Kholkute, Sanjeeva D

    2017-02-01

    Ultrasound is a powerful, low-cost, non-invasive medical tool used by laboratory animal veterinarians for diagnostic imaging. Sonohysterography and transvaginal ultrasound are frequently used to assess uterine anomalies in women presenting with abnormal uterine bleeding (AUB). In the present study, we have evaluated the abdominal ultrasound of bonnet monkeys ( n = 8) showing spontaneous ovulatory ( n = 5) and anovulatory ( n = 3) AUB. The ovulatory ( n = 5) macaques showed cyclic AUB for 7-8 days. The anovulatory ( n = 3) macaques had irregular AUB with menstrual cycles of 40-45 days. The B-mode abdominal, colour Doppler and 3D ultrasound scans were performed during the proliferative phase of the menstrual cycle. Ultrasound examination revealed endometrial polyps in five macaques and endometrial hyperplasia in three animals. The width and length of endometrial polyps was around 0.5-1 cm (average 0.51 ± 0.23 cm × 0.96 ± 0.16 cm) with significant increase in endometrial thickness ( P < 0.0002). 3D ultrasound also showed a homogeneous mass in the uterine cavity and colour Doppler ultrasound showed increased vascularity in the endometrial polyps. Endometrial hyperplasia characteristically appeared as a thickened echogenic endometrium ( P < 0.0002). This study demonstrates the use of non-invasive ultrasound techniques in the diagnosis of AUB in macaques.

  20. [Feasibility and accuracy of ultrasound-guided methodology in the examination of lumbar spine facet joints].

    PubMed

    Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui

    2013-03-01

    To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.

  1. Quantitative Contrast-Enhanced Ultrasound Parameters in Crohn Disease: Their Role in Disease Activity Determination With Ultrasound.

    PubMed

    Medellin-Kowalewski, Alexandra; Wilkens, Rune; Wilson, Alexandra; Ruan, Ji; Wilson, Stephanie R

    2016-01-01

    The primary objective of our study was to examine the association between contrast-enhanced ultrasound (CEUS) parameters and established gray-scale ultrasound with color Doppler imaging (CDI) for the determination of disease activity in patients with Crohn disease. Our secondary objective was to develop quantitative time-signal intensity curve thresholds for disease activity. One hundred twenty-seven patients with Crohn disease underwent ultrasound with CDI and CEUS. Reviewers graded wall thickness, inflammatory fat, and mural blood flow as showing remission or inflammation (mild, moderate, or severe). If both gray-scale ultrasound and CDI predicted equal levels of disease activity, the studies were considered concordant. If ultrasound images suggested active disease not supported by CDI findings, the ultrasound results for disease activity were indeterminate. Time-signal intensity curves from CEUS were acquired with calculation of peak enhancement (PE), and AUCs. Interobserver variation and associations between PE and ultrasound parameters were examined. Multiclass ROC analysis was used to develop CEUS thresholds for activity. Ninety-six (76%) studies were concordant, 19 of which showed severe disease, and 31 (24%) studies were indeterminate. Kappa analyses revealed good interobserver agreement on grades for CDI (κ = 0.76) and ultrasound (κ = 0.80) assessments. PE values on CEUS and wall thickness showed good association with the Spearman rank correlation coefficient for the entire population (ρ = 0.62, p < 0.01) and for the concordant group (ρ = 0.70, p < 0.01). Multiclass ROC analyses of the concordant group using wall thickness alone as the reference standard showed cutoff points of 18.2 dB for differentiating mild versus moderate activity (sensitivity, 89.0% and specificity, 87.0%) and 23.0 dB for differentiating moderate versus severe (sensitivity, 90% and specificity, 86.8%). Almost identical cutoff points were observed when using ultrasound global assessment as the reference standard: using 18.2 dB to differentiate mild versus moderate activity yielded sensitivity of 89.2% and specificity of 90.9% and using 22.9 dB to differentiate moderate versus severe activity yielded sensitivity of 89.5% and specificity of 83.1%. Quantitative CEUS parameters integrated into inflammatory assessments with ultrasound reduce indeterminate results and improve disease activity level determinations.

  2. High prevalence of all complex Segond avulsion using ultrasound imaging.

    PubMed

    Klos, Burt; Scholtes, Marlon; Konijnenberg, Stephan

    2017-04-01

    The aim of this study was to determine the prevalence of a Segond avulsion fractures in acute ACL tears with ultrasound and to investigate whether other injuries can predict the avulsion. One hundred thirty-eight ultrasound analyses of acute knee trauma were collected and scored for diagnosed injuries. The reports of patients with an ACL tear (N = 87) were evaluated to determine possible increased prevalence of Segond avulsion fracture with ultrasound. The associations between the diagnosed injuries and presence of a Segond avulsion were scored. The sports carried out at the time of injury were evaluated as possible prognostic factor. In 25/87 (29%) of the patients with an ACL tear, a Segond avulsion was observed in ultrasound. Lateral femoral condyle (LFC) impaction showed the strongest individual association with a Segond avulsion and was the best predicting variable. LFC impaction, sustained during low-risk pivoting sport, shows a stronger association with a Segond avulsion, as compared to LFC impaction sustained during high-risk pivoting sports. Ultrasound shows a higher prevalence of Segond avulsions as literature shows with MRI or radiography. LFC impaction is the best variable in predicting this type of avulsion. Ultrasound examination should be considered, if this fracture was not diagnosed with MRI or radiographic analysis. IV.

  3. Misuse of ultrasound for palpable undescended testis by primary care providers: A prospective study

    PubMed Central

    Wong, Nathan C.; Bansal, Rahul K.; Lorenzo, Armando J.; DeMaria, Jorge; Braga, Luis H.

    2015-01-01

    Introduction: Although previous evidence has shown that ultrasound is unreliable to diagnose undescended testis, many primary care providers (PCP) continue to misuse it. We assessed the performance of ultrasound as a diagnostic tool for palpable undescended testis, as well as the diagnostic agreement between PCP and pediatric urologists. Methods: We performed a prospective observational cohort study between 2011 and 2013 for consecutive boys referred with a diagnosis of undescended testis to our tertiary pediatric hospital. Patients referred without an ultrasound and those with non-palpable testes were excluded. Data on referring diagnosis, pediatric urology examination and ultrasound reports were analyzed. Results: Our study consisted of 339 boys. Of these, patients without an ultrasound (n = 132) and those with non-palpable testes (n = 38) were excluded. In the end, there were 169 pateints in this study. Ultrasound was performed in 50% of referred boys showing 256 undescended testis. The mean age at time of referral was 45 months. When ultrasound was compared to physical examination by the pediatric urologist, agreement was only 34%. The performance of ultrasound for palpable undescended testis was: sensitivity = 100%; specificity = 16%; positive predictive value = 34%; negative predictive value = 100%; positive likelihood ratio = 1.2; and negative likelihood ratio = 0. Diagnosis of undescended testis by PCP was confirmed by physical examination in 30% of cases, with 70% re-diagnosed with normal or retractile testes. Conclusion: Ultrasound performed poorly to assess for palpable undescended testis in boys and should not be used. Although the study has important limitations, there is an increasing need for education and evidence-based guidelines for PCP in the management of undescended testis. PMID:26788226

  4. Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

    PubMed

    Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H

    2006-12-01

    To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (p<0.01) and 0.328 (p<0.05), respectively. The ultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.

  5. FAST at MACH 20: clinical ultrasound aboard the International Space Station.

    PubMed

    Sargsyan, Ashot E; Hamilton, Douglas R; Jones, Jeffrey A; Melton, Shannon; Whitson, Peggy A; Kirkpatrick, Andrew W; Martin, David; Dulchavsky, Scott A

    2005-01-01

    Focused assessment with sonography for trauma (FAST) examination has been proved accurate for diagnosing trauma when performed by nonradiologist physicians. Recent reports have suggested that nonphysicians also may be able to perform the FAST examination reliably. A multipurpose ultrasound system is installed on the International Space Station as a component of the Human Research Facility. Nonphysician crew members aboard the International Space Station receive modest training in hardware operation, sonographic techniques, and remotely guided scanning. This report documents the first FAST examination conducted in space, as part of the sustained effort to maintain the highest possible level of available medical care during long-duration space flight. An International Space Station crew member with minimal sonography training was remotely guided through a FAST examination by an ultrasound imaging expert from Mission Control Center using private real-time two-way audio and a private space-to-ground video downlink (7.5 frames/second). There was a 2-second satellite delay for both video and audio. To facilitate the real-time telemedical ultrasound examination, identical reference cards showing topologic reference points and hardware controls were available to both the crew member and the ground-based expert. A FAST examination, including four standard abdominal windows, was completed in approximately 5.5 minutes. Following commands from the Mission Control Center-based expert, the crew member acquired all target images without difficulty. The anatomic content and fidelity of the ultrasound video were excellent and would allow clinical decision making. It is possible to conduct a remotely guided FAST examination with excellent clinical results and speed, even with a significantly reduced video frame rate and a 2-second communication latency. A wider application of trauma ultrasound applications for remote medicine on earth appears to be possible and warranted.

  6. Assessment of Lung Ultrasound B-Lines in Dogs with Different Stages of Chronic Valvular Heart Disease.

    PubMed

    Vezzosi, T; Mannucci, T; Pistoresi, A; Toma, F; Tognetti, R; Zini, E; Domenech, O; Auriemma, E; Citi, S

    2017-05-01

    In dogs with chronic valvular heart disease (CVHD), early recognition of pulmonary edema (PE) is of paramount importance. Recent studies in dogs showed that lung ultrasound examination (LUS) is a useful technique to diagnose cardiogenic PE. To describe LUS features in dogs with different stages of CVHD, and to determine its diagnostic accuracy in detecting PE using thoracic radiography as the reference standard. Sixty-three dogs with CVHD. Prospective, multicenter, cross-sectional study. Each dog underwent physical examination, echocardiography, thoracic radiography, and LUS. The LUS findings were classified as absent, rare, numerous, or confluent B-lines. Sensitivity, specificity, and positive and negative predictive values of LUS B-lines to identify PE were calculated using thoracic radiography as the reference standard. Dogs in stage B1 had absent or rare B-lines in 14 of 15 cases (93.3%). Dogs in stage B2 had absent or rare B-lines in 16 of 18 cases (88.9%). All dogs in stage C, without radiographic signs of PE, had absent or rare B-lines. Dogs in stage C, with radiographic signs of PE, had numerous or confluent B-lines in 18 of 20 cases (90%). Lung ultrasound examination detected PE with a sensitivity of 90%, specificity of 93%, and with positive and negative predictive values of 85.7 and 95.2%, respectively. Lung ultrasound examination showed good diagnostic accuracy to identify cardiogenic PE and might be helpful in staging dogs with CVHD. Lung ultrasound examination should be considered as a new, noninvasive diagnostic tool for clinicians managing CVHD in dogs. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article.

    PubMed

    Shi, Wen; Tian, Dan; Liu, Da; Yin, Jing; Huang, Ying

    2017-08-01

    Besides the study on examining facet joints of lumbar spine by ultrasound in normal population, there has not been any related report about examining normal facet joints of lumbar spine by ultrasound so far. This study was aimed to explore the feasibility of ultrasound assessment of lumber spine facet joints by comparing ultrasound measure values of normal and degenerative lumber spine facet joints, and by comparing measure values of ultrasound and computed tomography (CT) of degenerative lumber spine facet joints.This study included 15 patients who had chronic low back pain because of degenerative change in lumbar vertebrae, and 19 volunteers who did not have low back pain or pain in the lower limb. The ultrasound measure values (height [H] and width [W]) of normal and degenerative lumber spine facet joints were compared. And the differentiation between measure values (H and W) of ultrasound and CT of degenerative lumber spine facet joints was also analyzed.The ultrasound clearly showed abnormal facet joints lesion, which was characterized by hyperostosis on the edge of joints, bone destruction under joints, and thinner or thicker articular cartilage. There were significant differences between the ultrasound measure values of the normal (H: 1.26 ± 0.03 cm, W: 0.18 ± 0.01 cm) and abnormal facet joints (H: 1.43 ± 0.05 cm, W: 0.15 ± 0.02 cm) (all P < .05). However, there were no significant differences between the measure values of the ultrasound (H: 1.43 ± 0.17 cm, W: 0.15 ± 0.03 cm) and CT (H: 1.42 ± 0.16, W: 0.14 ± 0.03) of the degenerative lumber spine facet joints (all P > .05).Ultrasound can clearly show the structure of facet joints of lumbar spine. It is precise and feasible to assess facet joints of lumbar spine by ultrasound. This study has important significance for the diagnosis of lumbar facet joint degeneration.

  8. Ultrasound findings in children with toxocariasis: report on 18 cases.

    PubMed

    Baldisserotto, M; Conchin, C F; Soares, M da G; Araujo, M A; Kramer, B

    1999-05-01

    To evaluate abdominal ultrasound (US) findings in children infected with Toxocara canis. Eighteen children, 18 months to 7 years of age, with serological diagnosis of T.canis infection underwent abdominal US. Eosinophil counts, hemoglobin levels and immunoglobulin E titers were measured for all patients. Abdominal ultrasound revealed multiple hypoechoic areas in the livers of 15 patients (83.3%). Hepatohilar lymph-node enlargement was present in 14 patients (77.7%), 2 of whom also showed peripancreatic lymph-node enlargement. Hepatomegaly was present in 13 patients (72.7%) and splenomegaly in 9 (50%). The most prevalent findings of abdominal ultrasound examination of children with T.canis infection are hepatic granulomas and abdominal lymph-node enlargement. This infection should be considered in the differential diagnosis of any children who exhibit these findings on abdominal US examination, especially for those with eosinophilia.

  9. A Robust Model-Based Coding Technique for Ultrasound Video

    NASA Technical Reports Server (NTRS)

    Docef, Alen; Smith, Mark J. T.

    1995-01-01

    This paper introduces a new approach to coding ultrasound video, the intended application being very low bit rate coding for transmission over low cost phone lines. The method exploits both the characteristic noise and the quasi-periodic nature of the signal. Data compression ratios between 250:1 and 1000:1 are shown to be possible, which is sufficient for transmission over ISDN and conventional phone lines. Preliminary results show this approach to be promising for remote ultrasound examinations.

  10. Time-reversal acoustics and ultrasound-assisted convection-enhanced drug delivery to the brain.

    PubMed

    Olbricht, William; Sistla, Manjari; Ghandi, Gaurav; Lewis, George; Sarvazyan, Armen

    2013-08-01

    Time-reversal acoustics is an effective way of focusing ultrasound deep inside heterogeneous media such as biological tissues. Convection-enhanced delivery is a method of delivering drugs into the brain by infusing them directly into the brain interstitium. These two technologies are combined in a focusing system that uses a "smart needle" to simultaneously infuse fluid into the brain and provide the necessary feedback for focusing ultrasound using time-reversal acoustics. The effects of time-reversal acoustics-focused ultrasound on the spatial distribution of infused low- and high-molecular weight tracer molecules are examined in live, anesthetized rats. Results show that exposing the rat brain to focused ultrasound significantly increases the penetration of infused compounds into the brain. The addition of stabilized microbubbles enhances the effect of ultrasound exposure.

  11. Effect of ultrasound on electrochemical chloride extraction from mortar

    NASA Astrophysics Data System (ADS)

    Chen, Yiqun; Yao, Wu; Zuo, Junqing

    2018-03-01

    In this paper, the effect of auxiliary ultrasound on electrochemical chloride extraction (ECE) was studied. The chloride removal efficiency was investigated by examining the chloride content with ultrasound-assisted ECE and changing the introducing time of ultrasound. The experimental results showed that removal of chloride ions was noted to be more effective in ECE treatment assisted with ultrasound treatment (UT). In addition, the lower w/c ratio led to more distinct effect of ultrasonic cavitation on chloride removal. Electrochemical behaviors measured with different treatment revealed that UT treatment was effective on moderating the corrosion condition. Microstructural analyses revealed a significant alteration in composition and morphology of cementitious phases with UT treatment. Pull-out tests indicated that ultrasound had a certain negative impact on the bond strength. Although the effect of introducing ultrasound in the first 2 weeks or the last 2 weeks on the extraction efficiency was not obvious, intermittent ultrasound could not only ensure the chloride extraction efficiency, but also reduce the adverse effect of ultrasound on the bond strength.

  12. Transitional cell carcinoma of the bladder in children and adolescents: six-case series and review of the literature.

    PubMed

    Lerena, Javier; Krauel, Lucas; García-Aparicio, Luis; Vallasciani, Santiago; Suñol, Mariona; Rodó, Joan

    2010-10-01

    Lower urinary tract tumours are uncommon in paediatrics. Transitional cell carcinoma of the bladder (TCCB) is rarely found in the first two decades of life and is exceptional under 10 years of age. The present series aimed to expand the number of reported cases in the literature. In 1984-2007, six patients (four male, two female), aged 6, 9, 12, 13, 14 and 17 years, were treated at our centre. Clinical presentation was macroscopic haematuria in five and pyelonephritis in one. Physical examination, laboratory analysis, ultrasound and cystoscopy were performed before surgical treatment in all patients. Follow up was by clinical and ultrasound assessment. Neither physical examination nor laboratory analysis revealed any significant abnormalities, but ultrasound showed exophytic intravesical lesions. Surgical resection was performed endoscopically. Histological studies showed grade I TCCB in all cases. The immediate postoperative period was uneventful and long-term follow up did not reveal recurrence. Despite its low incidence in children, TCCB must be suspected in the event of macroscopic haematuria. Ultrasound followed by cystoscopy are the ideal diagnostic tools for visualization of these tumours. Endoscopic resection proved effective in all the present cases. Follow up must be clinical with periodic ultrasound evaluation. Urine cytologic examination is ineffective. Periodic cystoscopy is indicated only in cases of clinical or ultrasonographic suspicion of recurrence. Copyright © 2009 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  13. [Evidence of lacrimal plugs via high resolution ultrasound].

    PubMed

    Tost, Frank H W; Darman, Jacques

    2003-07-01

    The practical value of high-frequency ultrasound (transducer frequency of 20 MHz) for studying lacrimal plugs positioned into canaliculi was proved. Twelve patients with twenty intracanalicular plugs and two punctum plugs were examined via high-frequency B-scan ultrasonography using 20 MHz transducer (model I3 Sacramento, USA). Detection and localisation of the intracanalicular plugs was made by a 20 MHz sector scanner. The ultrasound examinations were performed 1 - 24 month after the placement of lacrimal plugs. After patient's head positioning, the high-frequency ultrasound investigation was done via immersion fluid (2 % methylcellulose). All patients with dry eye treated by lacrimal plug implant showed echographic structure in the lacrimal canaliculus. In transversal echograms it was possible to image both canaliculi together when the lids were half-closed. Contrary to the normal state, it was not necessary to inject viscous fluid into the canaliculus. High-resolution ultrasound was able to differentiate the normal canaliculus from the findings after plug placement. The echograms can vary from one plug type to another. Highly reflective structures were found after the placement of silicone intracanalicular plugs, e. g. HERRICK-Plug. In contrast, the ultrasonic image taken through acrylic polymer intracanalicular plugs showed homogeneous small reflective inner structure, e. g. SMART-Plug. However, smooth and flat acoustic interface between acrylic polymer plug and the lacrimal canaliculus produced strong echoes. 20 MHz ultrasound seems to be well suited for the detection and localisation of intracanalicular plugs. By use of 20 MHz ultrasound scans it is possible to get high-quality images of the intracanalicular plug and around lacrimal canaliculus. Compared with UBM, the depth of penetration is much higher with negligible resolution. On the whole, we believe that 20 MHz ultrasound can become a useful tool for evaluating the placement of intracanalicular plugs after insertion.

  14. Using Ultrasound to Enhance Medical Students' Femoral Vascular Physical Examination Skills.

    PubMed

    Ahn, Justin S; French, Andrew J; Thiessen, Molly E W; Browne, Vaughn; Deutchman, Mark; Guiton, Gretchen; Madigosky, Wendy; Kendall, John L

    2015-10-01

    To determine whether the addition of ultrasound to traditional physical examination instruction improves junior medical students' abilities to locate the femoral pulse. Initially, 150 second-year medical students were taught the femoral pulse examination using traditional bedside teaching on standardized patients and online didactic videos. Students were then randomized into 2 groups: group 1 received ultrasound training first and then completed the standardized examination; and group 2 performed the standardized examination first and then received ultrasound training. On the standardized patients, the femoral artery was marked with invisible ink before the sessions using ultrasound. Compared to these markers, students were then evaluated on the accuracy of femoral artery pulse palpation and the estimated location of the femoral vein. All students completed a self-assessment survey after the ultrasound sessions. Ultrasound training improved the students' ability to palpate the femoral pulse (P= .02). However, ultrasound did not facilitate correct estimation of the femoral vein's anatomic location (P = .09). Confidence levels in localizing the femoral artery and vein were equal between groups at baseline, and both increased after the ultrasound sessions. The addition of ultrasound teaching to traditional physical examination instruction enhanced medical student competency and confidence with the femoral vascular examination. However, understanding of anatomy may require emphasis on precourse didactic material, but further study is required. © 2015 by the American Institute of Ultrasound in Medicine.

  15. Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

    PubMed

    Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström

    2013-03-01

    To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  16. Ring down artefacts on abdominal sonography to predict pulmonary abnormalities in the emergency department.

    PubMed

    Tsai, C-L; Wang, H-P; Lien, W-C; Chen, C-C; Lai, T-I; Chen, W-J

    2005-10-01

    Ring down artefacts are sometimes found when emergency physicians perform abdominal ultrasound to differentiate between various abdominal problems. We describe a patient who presented with right upper quadrant abdominal pain and whose ultrasound examination showed ring down artefacts posterior to the right hemidiaphragm, which led to the eventual diagnosis of pneumonia. Ring down artefacts on ultrasound may be used to predict pulmonary abnormalities. Awareness of this sonographic finding may assist in accurate diagnosis and administration of appropriate treatment without delay.

  17. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    PubMed Central

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  18. Significance of ultrasound in the diagnosis and treatment of achilles tendon rupture.

    PubMed

    Poposka, A; Georgieva, D; Dzoleva-Tolevska, R

    2012-01-01

    The aim of this study is to show the importance of ultrasound method in the diagnosis of Achilles tendon rupture, the choice of method of treatment and monitoring of treatment using the same method. Between 1999 and 2009, 134 patients with Achilles tendon rupture were referred to our Clinic. 66 patients (with a mean age of 38 years) were treated with surgical suture followed by plaster immobilization for a period of 8 weeks. 68 patients (with a mean age of 42 years) were treated conservatively with plaster immobilization for a period of 8 weeks. The follow-up in both groups of patients was 2 years. During the clinical and ultrasound monitoring of the patients it was proved that repeated rupture of the same tendon occurs on average within 12 months. Return to sports activities showed in 57% of the conservatively treated patients and in 55% of surgically treated patients. The patients with Achilles tendon rupture were treated at our Clinic with previously standardized protocol which, besides the clinical examination, used the ultrasound method. Ultrasound examination is a very important method in the diagnosis and the choice of the method of treatment, as well as in the evaluation of results in patients with Achilles tendon rupture, either in operative or conservative treatment.

  19. Use of Ultrasound Elastography in the Assessment of the Musculoskeletal System.

    PubMed

    Paluch, Łukasz; Nawrocka-Laskus, Ewa; Wieczorek, Janusz; Mruk, Bartosz; Frel, Małgorzata; Walecki, Jerzy

    2016-01-01

    This article presents possible applications of ultrasound elastography in musculoskeletal imaging based on the available literature, as well as the possibility of extending indications for the use of elastography in the future. Ultrasound elastography (EUS) is a new method that shows structural changes in tissues following application of physical stress. Elastography techniques have been widely used to assess muscles and tendons in vitro since the early parts of the twentieth century. Only recently with the advent of new technology and creation of highly specialized ultrasound devices, has elastography gained widespread use in numerous applications. The authors performed a search of the Medline/PubMed databases for original research and reviewed publications on the application of ultrasound elastography for musculoskeletal imaging. All publications demonstrate possible uses of ultrasound elastography in examinations of the musculoskeletal system. The most widely studied areas include the muscles, tendons and rheumatic diseases. There are also reports on the employment in vessel imaging. The main limitation of elastography as a technique is above all the variability of applied pressure during imaging, which is operator-dependent. It would therefore be reasonable to provide clear guidelines on the technique applied, as well as clear indications for performing the test. It is important to develop methods for creating artifact-free, closed-loop, compression-decompression cycles. The main advantages include cost-effectiveness, short duration of the study, non-invasive nature of the procedure, as well as a potentially broader clinical availability. There are no clear guidelines with regard to indications as well as examination techniques. Ultrasound elastography is a new and still poorly researched method. We conclude, however, that it can be widely used in the examinations of musculoskeletal system. Therefore, it is necessary to conduct large, multi-center studies to determine the methodology, indications and technique of examination.

  20. [Contrast-enhanced Ultrasound in Diagnostic Imaging of Muscle Injuries: Perfusion Imaging in the Early Arterial Phase].

    PubMed

    Hotfiel, T; Carl, H D; Swoboda, B; Engelhardt, M; Heinrich, M; Strobel, D; Wildner, D

    2016-03-01

    Ultrasound is a standard procedure widely used in the diagnostic investigation of muscle injuries and widely described in the literature. Its advantages include rapid availability, cost effectiveness and the possibility to perform a real-time dynamic examination with the highest possible spatial resolution. In the diagnostic work-up of minor lesions (muscle stiffness, muscle strain), plain ultrasound has so far been inferior to MRI. The case presented by us is an example of the possibilities offered by contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries compared with plain B-mode image ultrasound and MRI imaging of the affected region. This case report is about a high-performance football player who sustained a muscle injury. He underwent an ultrasound examination (S 2000, 9L4 Probe, Siemens, Germany), which was performed simultaneously in the conventional and contrast-enhanced mode at the level of the lesion. An intravenous bolus injection of 4.8 ml of intravascular contrast agent (SonoVue(®), Bracco, Italy) was given via a cubital intravenous line. After that, the distribution of contrast agent was visualised in the early arterial phase. In addition, a plain magnetic resonance imaging scan of both thighs was performed for reference. On conventional ultrasound, the lesion was not clearly distinguishable from neighbouring tissue, whereas contrast-enhanced ultrasound demonstrated a well delineated, circumscribed area of impaired perfusion with hypoenhancement compared with the surrounding muscles at the clinical level of the lesion in the arterial wash-in phase (0-30 sec, after intravenous administration). The MRI scan revealed an edema signal with perifascial fluid accumulation in the corresponding site. The use of intravascular contrast agent enabled the sensitive detection of a minor injury by ultrasound for the first time. An intramuscular edema seen in the MRI scan showed a functional arterial perfusion impairment on ultrasound, which was sensitively detected in the early phase. Further examinations must be performed on muscle injuries of various degrees of severity in order to validate the application of this procedure and to standardise the examination process. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Time-reversal acoustics and ultrasound-assisted convection-enhanced drug delivery to the brain

    PubMed Central

    Olbricht, William; Sistla, Manjari; Ghandi, Gaurav; Lewis, George; Sarvazyan, Armen

    2013-01-01

    Time-reversal acoustics is an effective way of focusing ultrasound deep inside heterogeneous media such as biological tissues. Convection-enhanced delivery is a method of delivering drugs into the brain by infusing them directly into the brain interstitium. These two technologies are combined in a focusing system that uses a “smart needle” to simultaneously infuse fluid into the brain and provide the necessary feedback for focusing ultrasound using time-reversal acoustics. The effects of time-reversal acoustics-focused ultrasound on the spatial distribution of infused low- and high-molecular weight tracer molecules are examined in live, anesthetized rats. Results show that exposing the rat brain to focused ultrasound significantly increases the penetration of infused compounds into the brain. The addition of stabilized microbubbles enhances the effect of ultrasound exposure. PMID:23927197

  2. Refixation of Osteochondral Fractures by an Ultrasound-Activated Pin System - An Ovine In Vivo Examination Using CT and Scanning Electron Microscope.

    PubMed

    H, Neumann; A P, Schulz; S, Breer; A, Unger; B, Kienast

    2015-01-01

    Osteochondral injuries, if not treated appropriately, often lead to severe osteoarthritis of the affected joint. Without refixation of the osteochondral fragment, human cartilage only repairs these defects imperfectly. All existing refixation systems for chondral defects have disadvantages, for instance bad MRI quality in the postoperative follow-up or low anchoring forces. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants a higher anchoring is assumed. Aim of the study was to investigate, if ultrasound-activated pins can provide a secure refixation of osteochondral fractures comparing to conventional screw and conventional, resorbable pin osteosynthesis. CT scans and scanning electron microscopy should proovegood refixation results with no further tissue damage by the melting of the ultrasound-activated pins in comparison to conventional osteosynthesis. Femoral osteochondral fragments in sheep were refixated with ultrasound-activated pins (SonicPin™), Ethipins(®) and screws (Asnis™). The quality of the refixated fragments was examined after three month of full weight bearing by CT scans and scanning electron microscopy of the cartilage surface. The CT examination found almost no statistically significant difference in the quality of refixation between the three different implants used. Concerning the CT morphology, ultrasound-activated pins demonstrated at least the same quality in refixation of osteochondral fragments as conventional resorbable pins or screws. The scanning electron microscopy showed no major surface damage by the three implants, especially any postulated cartilage damage induced by the heat of the ultrasound-activated pin. The screws protruded above the cartilage surface, which may affect the opposingtibial surface. Using CT scans and scanning electron microscopy, the SonicPin™, the Ethipin(®) and screws were at least equivalent in refixation quality of osteochondral fragments.

  3. Cardiac Limited Ultrasound Examination Techniques to Augment the Bedside Cardiac Physical Examination.

    PubMed

    Kimura, Bruce J; Shaw, David J; Amundson, Stan A; Phan, James N; Blanchard, Daniel G; DeMaria, Anthony N

    2015-09-01

    The current practice of physical diagnosis is dependent on physician skills and biases, inductive reasoning, and time efficiency. Although the clinical utility of echocardiography is well known, few data exist on how to integrate 2-dimensional screening "quick-look" ultrasound applications into a novel, modernized cardiac physical examination. We discuss the evidence basis behind ultrasound "signs" pertinent to the cardiovascular system and elemental in synthesis of bedside diagnoses and propose the application of a brief cardiac limited ultrasound examination based on these signs. An ultrasound-augmented cardiac physical examination can be taught in traditional medical education and has the potential to improve bedside diagnosis and patient care. © 2015 by the American Institute of Ultrasound in Medicine.

  4. Diagnostic value of ultrasound indicators of neoplastic risk in preoperative differentiation of adnexal masses

    PubMed Central

    Bachanek, Michał; Trojanowski, Seweryn; Cendrowski, Krzysztof; Sawicki, Włodzimierz

    2013-01-01

    Aim To assess the diagnostic value of the risk of malignancy indices and simple ultrasound- based rules in preoperative differentiation of adnexal masses. Material and methods Retrospective examination of 87 patients admitted to hospital due to adnexal tumors. The lesions were evaluated on the basis of international ultrasound classification of ovarian tumors and four risk of malignancy indices were calculated based on ultrasound examination, concentration of CA 125 and menopausal status. Results The patients were aged between 17 and 79, the mean age was 44.5 (standard deviation SD=16.6). Most of the patients (60.91%) were before their menopause. The sensitivity of the simple ultrasound-based rules in the diagnosis of malignancies equaled 64.71% and the specificity constituted 90.00%. A significant statistical difference in the presence of the malignant process was demonstrated in relation to age, menopausal status, CA 125 concentration and analyzed ultrasound score. All indices were characterized by similar sensitivity and specificity. The highest specificity and predictive value of malignant lesions out of the assessed ones was demonstrated by the risk of malignancy index proposed by Yamamoto. The risk of malignancy index according to Jacobs, however, showed the highest predictive value in the case of non-malignant lesions. Conclusions The multiparametric ultrasound examination may facilitate the selection of patients with adnexal tumors to provide them with an appropriate treatment – observation, laparotomy and laparoscopy. These parameters constitute a simple ambulatory method of determining the character of adnexal masses before recommending appropriate treatment. PMID:26674849

  5. Influence of mixing and ultrasound frequency on antisolvent crystallisation of sodium chloride.

    PubMed

    Lee, Judy; Ashokkumar, Muthupandian; Kentish, Sandra E

    2014-01-01

    Ultrasound is known to promote nucleation of crystals and produce a narrower size distribution in a controlled and reproducible manner for the crystallisation process. Although there are various theories that suggest cavitation bubbles are responsible for sonocrystallisation, most studies use power ultrasonic horns that generate both intense shear and cavitation and this can mask the role that cavitation bubbles play. High frequency ultrasound from a plate transducer can be used to examine the effect of cavitation bubbles without the intense shear effect. This study reports the crystal size and morphology with various mixing speeds and ultrasound frequencies. The results show high frequency ultrasound produced sodium chloride crystals of similar size distribution as an ultrasonic horn. In addition, ultrasound generated sodium chloride crystals having a more symmetrical cubic structure compared to crystals produced by a high shear mixer. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Imaging late capsular block syndrome: ultrasound biomicroscopy versus Scheimpflug camera.

    PubMed

    Kucukevcilioglu, Murat; Hurmeric, Volkan; Erdurman, Fazıl Cuneyt; Ceylan, Osman Melih

    2011-11-01

    We describe 2 patients with late capsular block syndrome whose anterior chamber morphology was evaluated with ultrasound biomicroscopy and Scheimpflug imaging before and after neodymium:YAG laser capsulotomy. Pretreatment ultrasound biomicroscopy examination showed significant capsular bag distension in both patients. Scheimpflug imaging failed to capture the posterior capsule displaced far behind the intraocular lens. Automatic anterior chamber depth measurements were incorrect with Scheimpflug imaging in 1 patient. Ultrasound biomicroscopy seems to be superior to Scheimpflug imaging in eyes with extremely distended capsular bags. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Monitoring Progression of Amyotrophic Lateral Sclerosis Using Ultrasound Morpho-Textural Muscle Biomarkers: A Pilot Study.

    PubMed

    Martínez-Payá, Jacinto J; Ríos-Díaz, José; Medina-Mirapeix, Francesc; Vázquez-Costa, Juan F; Del Baño-Aledo, María Elena

    2018-01-01

    The need is increasing for progression biomarkers that allow the loss of motor neurons in amyotrophic lateral sclerosis (ALS) to be monitored in clinical trials. In this prospective longitudinal study, muscle thickness, echointensity, echovariation and gray level co-occurrence matrix textural features are examined as possible progression ultrasound biomarkers in ALS patients during a 5-mo follow-up period. We subjected 13 patients to 3 measurements for 20 wk. They showed a significant loss of muscle, an evident tendency to loss of thickness and increased echointensity and echovariation. In regard to textural parameters, muscle heterogeneity tended to increase as a result of the neoformation of non-contractile tissue through denervation. Considering some limitations of the study, the quantitative muscle ultrasound biomarkers evaluated showed a promising ability to monitor patients affected by ALS. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  8. Internal Medicine Residents' Retention of Knowledge and Skills in Bedside Ultrasound.

    PubMed

    Town, James A; Bergl, Paul A; Narang, Akhil; McConville, John F

    2016-10-01

    The long-term retention of knowledge and skills in bedside ultrasound by internal medicine residents after ultrasound training is not well understood. We sought to determine whether knowledge and skills acquired from focused training in bedside ultrasound are retained over time, and whether retention is related to independent practice. We conducted a prospective observational trial of 101 internal medicine residents at an academic medical center who participated in a bedside ultrasound workshop followed by 12 months of independent practice. Performance was measured on image-based knowledge and skills assessment using direct observation, both before the workshop and 12 months later. Individual usage data were obtained along with a survey on attitudes toward bedside ultrasound. Participants' mean knowledge assessment score increased from a baseline of 63.7% to 84.5% immediately after training ( P  < .001). At 12 months, mean knowledge score fell to 73.0%, significantly different from both prior assessments ( P  < .001). Despite knowledge decline, the mean skills assessment score improved from a baseline of 30.5% to 50.4% at 12 months ( P  < .001). Residents reporting more ultrasound use (> 25 examinations) had higher scores in baseline knowledge and skills assessments than those with lower usage (< 25 examinations). Change in knowledge and image acquisition skills between assessments was equal in both subgroups. Residents' knowledge of ultrasound improved after brief training but decayed over time, whereas skills showed marginal improvement over the study, with minimal support. Growth and retention of ultrasound abilities were not impacted by usage rates.

  9. Internal Medicine Residents' Retention of Knowledge and Skills in Bedside Ultrasound

    PubMed Central

    Town, James A.; Bergl, Paul A.; Narang, Akhil; McConville, John F.

    2016-01-01

    ABSTRACT Background  The long-term retention of knowledge and skills in bedside ultrasound by internal medicine residents after ultrasound training is not well understood. Objective  We sought to determine whether knowledge and skills acquired from focused training in bedside ultrasound are retained over time, and whether retention is related to independent practice. Methods  We conducted a prospective observational trial of 101 internal medicine residents at an academic medical center who participated in a bedside ultrasound workshop followed by 12 months of independent practice. Performance was measured on image-based knowledge and skills assessment using direct observation, both before the workshop and 12 months later. Individual usage data were obtained along with a survey on attitudes toward bedside ultrasound. Results  Participants' mean knowledge assessment score increased from a baseline of 63.7% to 84.5% immediately after training (P < .001). At 12 months, mean knowledge score fell to 73.0%, significantly different from both prior assessments (P < .001). Despite knowledge decline, the mean skills assessment score improved from a baseline of 30.5% to 50.4% at 12 months (P < .001). Residents reporting more ultrasound use (> 25 examinations) had higher scores in baseline knowledge and skills assessments than those with lower usage (< 25 examinations). Change in knowledge and image acquisition skills between assessments was equal in both subgroups. Conclusions  Residents' knowledge of ultrasound improved after brief training but decayed over time, whereas skills showed marginal improvement over the study, with minimal support. Growth and retention of ultrasound abilities were not impacted by usage rates. PMID:27777666

  10. Effect of pulsed ultrasound in combination with gentamicin on bacterial viability in biofilms on bone cements in vivo.

    PubMed

    Ensing, G T; Roeder, B L; Nelson, J L; van Horn, J R; van der Mei, H C; Busscher, H J; Pitt, W G

    2005-01-01

    The aim of this study is to investigate whether pulsed ultrasound (US) in combination with gentamicin yields a decreased viability of bacteria in biofilms on bone cements in vivo. Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with an Escherichia coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement discs loaded with gentamicin, freshly prepared and aged were used, and in one group unloaded bone cement discs in combination with systemically administered gentamicin. Pulsed ultrasound with a frequency of 28.48 kHz and a maximum acoustic intensity of 500 mW cm(-2) was applied continuously from 24 h till 72 h postsurgery on one of the two implanted discs. After euthanization and removal of the bacteria from the discs, the number of viable bacteria were quantified and skin samples were analysed for histopathological examination. Application of ultrasound, combined with gentamicin, reduced the viability of the biofilms in all three groups varying between 58 and 69% compared with the negative control. Histopathological examinations showed no skin lesions. Ultrasound resulted in a tendency of improved efficacy of gentamicin, either applied locally or systemically. Usage of ultrasound in this model proved to be safe. This study implies that ultrasound could improve the prevention of infection immediately after surgery, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice.

  11. Imaging of idle breast implants with ultrasound-strain elastography- A first experimental study to establish criteria for accurate imaging of idle implants via ultrasound-strain elastography.

    PubMed

    Kuehlmann, Britta; Prantl, Lukas; Michael Jung, Ernst

    2016-01-01

    To investigate whether there are fundamental sonographic and elastographic criteria to precisely assess different surfaces and fillings of idle breast implants and to determine their most distinctive parameters. This was a comparative study of different unused breast implant materials, neighter in animals nor in humans. This knowledge should be transferred in vivo to develop an objective measurement tool. Nine idle breast implants-silicone and polyurethane (PU)-were examined in an experimental study by using ultrasound B-mode with tissue harmonic imaging (THI), speckle reduction imaging (SRI, level 0-4), cross-beam (CB, low, medium, high), photopic and the colour coded ultrasound-strain elastography with a multifrequency probe (9-15 MHz).Using a standardised protocol the implants' centre as well as the edge were analysed by one experienced examiner. Two independent readers performed analysis and evaluation. For image interpretation a score was created (score 0:inadequate image, score 5:best image quality). The highest score result for the centre was achieved by using ultrasound with B-mode in addition with CB level medium, SRI level 2, THI and photopic (mean:3.22±SD:1.56), but without any statistic significant difference (t-value = 0.71). With elastography the implants' edge in general was represented without disruptive artefacts (3.89±0.60) with statistic significant difference (t-value = 5.29). Implants filled with inner cohesive silicone gel II° showed best imaging conditions for their centre via ultrasound (5±0) as well as for their edge via elastography (4.50±0.71). Ultrasound-strain elastography and high resolution ultrasound represent a valuable measurement tool to evaluate different properties of idle breast implants. These modified ultrasound examinations could be an additional help for clinical investigations and be correlated with Baker's Classification.

  12. Downstream Imaging Utilization After Emergency Department Ultrasound Interpreted by Radiologists Versus Nonradiologists: A Medicare Claims-Based Study.

    PubMed

    Allen, Bibb; Carrol, L Van; Hughes, Danny R; Hemingway, Jennifer; Duszak, Richard; Rosenkrantz, Andrew B

    2017-04-01

    To study differences in imaging utilization downstream to initial emergency department (ED) ultrasound examinations interpreted by radiologists versus nonradiologists. Using 5% Medicare Research Identifiable Files from 2009 to 2014, we identified episodes where the place of service was "emergency room hospital" and the patient also underwent an ultrasound examination. We determined whether the initial ultrasound was interpreted by a radiologist or nonradiologist and then summed all additional imaging events occurring within 7, 14, and 30 days of each initial ED ultrasound. For each year and each study window, we calculated the mean number of downstream imaging procedures by specialty group. Of 200,357 ED ultrasound events, 163,569 (81.6%) were interpreted by radiologists and 36,788 (18.4%) by nonradiologists. Across all study years, ED patients undergoing ultrasound examinations interpreted by nonradiologists underwent 1.08, 1.22, and 1.34 additional diagnostic imaging studies at 7, 14, and 30 days, respectively (P < .01) compared with when the initial ultrasound examination was interpreted by a radiologist. From 2010 to 2014, the volume of downstream imaging for both radiologists and nonradiologists significantly decreased, with each year resulting in 0.08 fewer imaging examinations (P < .001) 14 days after the ED ultrasound event. Despite that decline, differences in downstream imaging between radiologists and nonradiologists persisted over time. Downstream imaging after an initial ED ultrasound is significantly reduced when the ultrasound examination is interpreted by a radiologist rather than a nonradiologist. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Ultrasound hepatic/renal ratio and hepatic attenuation rate for quantifying liver fat content.

    PubMed

    Zhang, Bo; Ding, Fang; Chen, Tian; Xia, Liang-Hua; Qian, Juan; Lv, Guo-Yi

    2014-12-21

    To establish and validate a simple quantitative assessment method for nonalcoholic fatty liver disease (NAFLD) based on a combination of the ultrasound hepatic/renal ratio and hepatic attenuation rate. A total of 170 subjects were enrolled in this study. All subjects were examined by ultrasound and (1)H-magnetic resonance spectroscopy ((1)H-MRS) on the same day. The ultrasound hepatic/renal echo-intensity ratio and ultrasound hepatic echo-intensity attenuation rate were obtained from ordinary ultrasound images using the MATLAB program. Correlation analysis revealed that the ultrasound hepatic/renal ratio and hepatic echo-intensity attenuation rate were significantly correlated with (1)H-MRS liver fat content (ultrasound hepatic/renal ratio: r = 0.952, P = 0.000; hepatic echo-intensity attenuation r = 0.850, P = 0.000). The equation for predicting liver fat content by ultrasound (quantitative ultrasound model) is: liver fat content (%) = 61.519 × ultrasound hepatic/renal ratio + 167.701 × hepatic echo-intensity attenuation rate -26.736. Spearman correlation analysis revealed that the liver fat content ratio of the quantitative ultrasound model was positively correlated with serum alanine aminotransferase, aspartate aminotransferase, and triglyceride, but negatively correlated with high density lipoprotein cholesterol. Receiver operating characteristic curve analysis revealed that the optimal point for diagnosing fatty liver was 9.15% in the quantitative ultrasound model. Furthermore, in the quantitative ultrasound model, fatty liver diagnostic sensitivity and specificity were 94.7% and 100.0%, respectively, showing that the quantitative ultrasound model was better than conventional ultrasound methods or the combined ultrasound hepatic/renal ratio and hepatic echo-intensity attenuation rate. If the (1)H-MRS liver fat content had a value < 15%, the sensitivity and specificity of the ultrasound quantitative model would be 81.4% and 100%, which still shows that using the model is better than the other methods. The quantitative ultrasound model is a simple, low-cost, and sensitive tool that can accurately assess hepatic fat content in clinical practice. It provides an easy and effective parameter for the early diagnosis of mild hepatic steatosis and evaluation of the efficacy of NAFLD treatment.

  14. [Early prediction of the neurological result at 12 months in newborns at neurological risk].

    PubMed

    Herbón, F; Garibotti, G; Moguilevsky, J

    2015-08-01

    The aim of this study was to evaluate the Amiel-Tison neurological examination (AT) and cranial ultrasound at term for predicting the neurological result at 12 months in newborns with neurological risk. The study included 89 newborns with high risk of neurological damage, who were discharged from the Neonatal Intensive Care of the Hospital Zonal Bariloche, Argentina. The assessment consisted of a neurological examination and cranial ultrasound at term, and neurological examination and evaluation of development at 12 months. The sensitivity, specificity, positive and negative predictor value was calculated. The relationship between perinatal factors and neurodevelopment at 12 month of age was also calculated using logistic regression models. Seventy children completed the follow-up. At 12 months of age, 14% had an abnormal neurological examination, and 17% abnormal development. The neurological examination and the cranial ultrasound at term had low sensitivity to predict abnormal neurodevelopment. At 12 months, 93% of newborns with normal AT showed normal neurological results, and 86% normal development. Among newborns with normal cranial ultrasound the percentages were 90 and 81%, respectively. Among children with three or more perinatal risk factors, the frequency of abnormalities in the neurological response was 5.4 times higher than among those with fewer risk factors, and abnormal development was 3.5 times more frequent. The neurological examination and cranial ultrasound at term had low sensitivity but high negative predictive value for the neurodevelopment at 12 months. Three or more perinatal risk factors were associated with neurodevelopment abnormalities at 12 months of age. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  15. Intraoperative ultrasound for prediction of hepatocellular carcinoma biological behaviour: Prospective comparison with pathology.

    PubMed

    Santambrogio, Roberto; Cigala, Claudia; Barabino, Matteo; Maggioni, Marco; Scifo, Giovanna; Bruno, Savino; Bertolini, Emanuela; Opocher, Enrico; Bulfamante, Gaetano

    2018-02-01

    Preoperative prediction of both microinvasive hepatocellular carcinoma and histological grade of hepatocellular carcinoma is pivotal to treatment planning and prognostication. The aim of this study was to evaluate whether some intraoperative ultrasound features correlate with both the presence of same histological patterns and differentiation grade of hepatocellular carcinoma on the histological features of the primary resected tumour. All patients with single, small hepatocellular carcinoma that underwent hepatic resection were included in this prospective double-blind study: the intraoperative ultrasound patterns of nodule were registered and compared with similar histological features. A total of 179 patients were enclosed in this study: 97 (54%) patients (34% in HCC ≤2 cm) had a microinvasive hepatocellular carcinoma at ultrasound examination, while 82 (46%) patients (41% in HCC ≤2 cm) at histological evaluation. Statistical analysis showed that diameters ≤2 cm, presence of satellites and microinvasive hepatocellular carcinoma at ultrasound examination were the variables with the strongest association with the histological findings. In the multivariate analysis, the vascular microinfiltration and infiltrative hepatocellular carcinoma aspect were independent predictors for grading. In patients with cirrhosis and hepatocellular carcinoma, the prevalence of microinvasive hepatocellular carcinoma is high, even in cases of HCC ≤2 cm. Intraoperative ultrasound findings strongly correlated with histopathological criteria in detecting microinvasive patterns and are useful to predict neoplastic differentiation. The knowledge of these features prior to treatment are highly desired (this can be obtained by an intraoperative ultrasound examination), as they could help in providing optimal management of patients with hepatocellular carcinoma. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Comparison of low and high frequency transducers in the detection of liver metastases.

    PubMed

    Schacherer, D; Wrede, C; Obermeier, F; Schölmerich, J; Schlottmann, K; Klebl, F

    2006-09-01

    To evaluate the benefit of the additional use of a high frequency ultrasound probe (7.5 MHz) in finding suspicious liver lesions compared to the examination using a 3.5-MHz transducer only. One hundred and fifty-seven patients with underlying malignant disease were examined with both transducers using one of three ultrasound machines (Siemens Sonoline Elegra, GE Healthcare Logic 9, or Hitachi EUB-8500). Findings on hepatic lesions were collected on a standardised documentation sheet and evaluated by descriptive statistics. Ninety-three patients (59.2% of all patients) showed no evident liver lesion on conventional ultrasound with the 3.5 MHz probe. In 29 patients (18.5%) new suspicious liver lesions were found by using the high frequency transducer. Thirteen of these 29 patients (44.8%) were suspected to suffer from diffuse infiltration of the liver with malignant lesions or at least 10 additional visible lesions. In 14 patients, no liver lesion had been known before high frequency ultrasound examination. The size of newly described liver lesions ranged from 2 mm to 1.5 cm. Time needed for the additional examination with the high frequency transducer ranged between 1 and 15 min with an average of 4.0 min. The additional use of a high frequency transducer in patients with underlying malignant disease slightly extends the examination time, but reveals new, potentially malignant hepatic lesions in almost every fifth patient.

  17. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography

    PubMed Central

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-01-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio <1, microcalcification and irregular peripheral echo halo, and there were statistically significant differences compared with the benign nodules (P<0.05). UE showed that the differences between benign and malignant nodules in 2, 3 and 4 points were statistically significant (P<0.05). The manifestations of malignant nodules in UC were mostly the irregular shape, obscure boundary, no obvious enhancement, heterogeneous enhancement and visible perfusion defects, and there were statistically significant differences compared with the benign nodules (P<0.05). ROC curve showed that both sensitivity and specificity of UE and UC were superior to those of conventional US. AUC was the largest (AUC = 0.908) and the diagnostic value was the highest in the conventional US combined with UE and UC. Conventional US combined with elastography and UC can significantly improve the sensitivity, specificity and accuracy of diagnosis of benign and malignant thyroid nodules. PMID:28693244

  18. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography.

    PubMed

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-07-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio <1, microcalcification and irregular peripheral echo halo, and there were statistically significant differences compared with the benign nodules (P<0.05). UE showed that the differences between benign and malignant nodules in 2, 3 and 4 points were statistically significant (P<0.05). The manifestations of malignant nodules in UC were mostly the irregular shape, obscure boundary, no obvious enhancement, heterogeneous enhancement and visible perfusion defects, and there were statistically significant differences compared with the benign nodules (P<0.05). ROC curve showed that both sensitivity and specificity of UE and UC were superior to those of conventional US. AUC was the largest (AUC = 0.908) and the diagnostic value was the highest in the conventional US combined with UE and UC. Conventional US combined with elastography and UC can significantly improve the sensitivity, specificity and accuracy of diagnosis of benign and malignant thyroid nodules.

  19. [Evaluation of the diagnosis of subclinical endometritis in dairy cattle using ultrasound].

    PubMed

    Lenz, Mirjam; Drillich, Marc; Heuwieser, Wolfgang

    2007-01-01

    The aim of this study was to determine signs of subclinical endometritis found by ultrasound that are associated with reduced fertility in dairy cows. The maximum diameter of the uterine lumen was determined by ultrasound in 324 cows without clinical signs of endometritis after evaluation of the genital tract 21 to 27 days postpartum. Cows were classified into healthy or with subclinical endometritis by three threshold values for the maximum uterine lumen diameter of 0.2 cm, 0.5 cm or 0.8 cm. Examinations by rectal palpation and ultrasound as well as classifications were repeated 14 days later. In addition, ovaries were scanned by ultrasound to determine the stage of the estrous cycle. In a subgroup of 103 cows the echotexture of the uterus and its contents was evaluated. In these cows the diagnosis of subclinical endometritis was performed by a scoring system. The diameter of the uterine lumen was significantly affected by stage of the estrous cycle at the time of examination. However, no effects were found for the stage of the cycle at the time of examination on subsequent reproductive performance. A uterine lumen with a maximum diameter of more than 0.2 cm showed a significant negative association with conception rate and proportion of cows pregnant. Classification based on higher threshold values did not reveal an association with reproductive performance. Echogenic content in the uterus also decreased reproductive performance. A classification based on the echotexture of the uterus and its contents revealed significant differences between healthy cows and cows with subclinical endometritis regarding the proportion of cows inseminated and pregnant. The results of this study showed that the diagnostic of bovine endometritis should be broadend by ultrasonography. The definition of subclinical endometritis diagnosed by means of ultrasonography has to be evaluated in further studies.

  20. An Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer

    DTIC Science & Technology

    1998-12-01

    is similar to those of the study by Ivey et al. [9] in which high intensity fields were used to produce cavitation bubbles for ultrasound contrast...ft * * AD AWARD NUMBER DAMD17-94-J-4144 TITLE: ^ Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer...Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer 3. REPORT TYPE AND DATES COVERED Final (1 Jun 94 - 30 Nov 98) 5. FUNDING

  1. Standards of the Polish Ultrasound Society - update. Ultrasound examination of the kidneys, ureters and urinary bladder.

    PubMed

    Tyloch, Janusz F; Woźniak, Magdalena Maria; Wieczorek, Andrzej Paweł

    2013-09-01

    The paper presents the principles of performing proper ultrasound examinations of the urinary tract. The following are discussed: preparation of patients, type of optimal apparatus, technique of examination and conditions which its description should fulfill. Urinary track examination in adults and in children constitutes an integral part of each abdominal examination. Such examinations should be performed with fasting patients or several hours after the last meal, with filled urinary bladder. Ultrasound examinations in children and infants are performed using transducers with the frequency of 5.0-9.0 MHz and in adults - with the frequency of 2.0-6.0 MHz. Doppler options are desirable since they improve diagnostic capacity of sonography in terms of differentiation between renal focal lesions. Renal examinations are performed with the patients in the supine position. The right kidney is examined in the right hypochondriac region using the liver as the ultrasound "window." The left kidney is examined in the left hypochondriac region, preferably in the posterior axillary line. Ultrasound examinations of the upper segment of the ureters are performed after renal examination when the pelvicalyceal system is dilated. A condition necessary for a proper examination of the perivesical portion of the ureter is full urinary bladder. The scans of the urinary bladder are performed in transverse, longitudinal and oblique planes when the bladder is filled. The description should include patient's personal details, details of the referring unit, of the unit in which the examination is performed, examining physician's details, type of ultrasound apparatus and transducers as well as the description proper.

  2. Outcome for children infected with congenital toxoplasmosis in the first trimester and with normal ultrasound findings: a study of 36 cases.

    PubMed

    Berrebi, Alain; Bardou, Magali; Bessieres, Marie-Hélène; Nowakowska, Dorota; Castagno, Romina; Rolland, Michel; Wallon, Martine; Franck, Jacqueline; Bongain, André; Monnier-Barbarino, Patricia; Assouline, Corinne; Cassaing, Sophie

    2007-11-01

    We wished to investigate the prognosis of children infected with Toxoplasma gondii during the first trimester of pregnancy and whose ultrasound findings were entirely normal, in order to find out whether congenital toxoplasmosis did or did not justify termination of pregnancy if there was no fetal abnormality on ultrasound. A prospective and retrospective study was carried out by 12 French centers who enrolled 36 children infected with T. gondii during the first trimester of pregnancy and whose ultrasound examinations showed no anomaly. The outcome of these children after the age of 12 months (mean 50 months, range 12-144 months) was analyzed. Of the 36 infected children, 28 (78%) presented subclinical toxoplasmosis. Only specific IgG antibodies persisted after 1 year. The principal manifestation in 7 children (19%) was chorioretinitis without major vision loss. Their intellectual development was entirely normal. One child (3%) developed severe congenital toxoplasmosis. Since 97% of children infected with toxoplasmosis during the first trimester of pregnancy are asymptomatic or only slightly affected, we believe that in such circumstances termination of pregnancy is not indicated. However, appropriate treatment is essential and prenatal ultrasound examinations should be free of any anomaly.

  3. Frequency of postnatal hydronephrosis in infants with a renal anterior-posterior pelvic diameter > 4 mm on midtrimester ultrasound.

    PubMed

    Chou, Ching-Yu; Chen, Li-Ching; Cheong, Mei-Leng; Tsai, Ming-Song

    2015-10-01

    To examine the association of antenatal renal pelvic dilatation observed on midtrimester ultrasound screening with the presence of hydronephrosis in newborn infants. The records of patients who received fetal ultrasound examination at 18-28 weeks' gestation from May 2008 to March 2012 were retrospectively reviewed. A fetal renal pelvic anterior-posterior (AP) diameter > 4 mm was considered abnormal and ≤ 4 mm was considered normal. On postnatal ultrasound, a renal pelvic AP diameter > 3 mm was considered to indicate hydronephrosis and ≤ 3 mm was considered normal. The association of postnatal hydronephrosis with prenatal pelvic AP diameter was determined using binary logistic regression analysis. The study comprised 1310 newborn infants: 684 (52.2%) male and 626 (47.8%) female. Multivariate analysis showed a right or left prenatal AP renal pelvic diameter > 4 mm was associated with a higher risk of postnatal hydronephrosis compared with a right and left prenatal AP renal pelvic diameter ≤ 4 mm. Boys had a higher risk for postnatal hydronephrosis than girls (odds ratio = 2.42, p < 0.05). An antenatal renal pelvic AP diameter > 4 mm on midtrimester ultrasound is predictive of postnatal hydronephrosis. Copyright © 2015. Published by Elsevier B.V.

  4. Fast Track ultrasound protocol to detect acute complications after totally implantable venous access device placement.

    PubMed

    Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng

    2015-01-01

    The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.

  5. Ultrasound detection of placenta accreta in the first trimester of pregnancy.

    PubMed

    Rahimi-Sharbaf, Fatemeh; Jamal, Ashraf; Mesdaghinia, Elaheh; Abedzadeh-Kalahroudi, Masoumeh; Niroomanesh, Shirin; Atoof, Fatemeh

    2014-06-01

    Placenta accreta is considered a life-threatening condition and the main cause of maternal mortality. Prenatal diagnosis of placenta accreta usually is made by clinical presentation, imaging studies like ultrasound and MRI in the second and third trimester. To determine accuracy of ultrasound findings for placenta accreta in the first trimester of pregnancy. In a longitudinal study 323 high risk patients for placenta accreta were assessed. The eligible women were examined by vaginal and abdominal ultrasound for gestational sac and placental localization and they were followed up until the end of pregnancy. The ultrasound findings were compared with histopathological examinations as a gold standard. The sensitivity, specificity, positive and negative predictive value of ultrasound were estimated for the first trimester and compared with other 2 trimesters in the case of repeated ultrasound examination. Ultrasound examinations in the first trimester revealed that 28 cases had the findings in favor of placenta accreta which ultimately was confirmed in 7 cases. The ultrasound sensitivity and specificity for detecting placenta accreta in the first trimester was 41% [95% CI: 16.2-62.7] and 88% [95% CI: 88.2-94.6] respectively. Ultrasound screening for placenta accreta in the first trimester of pregnancy could not achieve the high sensitivity as second and third trimester of pregnancy.

  6. [Contribution of pelvic echography to the diagnosis of malformations of the utero-vaginal tract].

    PubMed

    Ellart, D; Houze de l'Aulnoit, H; Corette, L; Delcroix, M; Brabant, G

    1990-01-01

    Pelvic ultrasound has become very important in the diagnostic planning of utero-vaginal malformations. Having studies 93 congenital malformations of the utero-vaginal tract, the authors used ultrasound investigations as a first or second line of approach. They are able to describe the way ultrasound can be used for each type of malformation. Ultrasound is undeniably reliable for diagnosing bilateral incomplete aplasia of the uterus; so avoiding the need for laparoscopy. When failure of the uterus to develop on one side occurs it is possible to look for a closed or canalized rudimentary uterine nodule to confirm the diagnosis of a pseudo-unicorn uterus. The diagnosis by ultrasound of a bifid uterus shows up by the appearance of a "V" shape on the bladder. An intra-uterine septum can be diagnosed according to how serious the embryological abnormality is on ultrasound. Similarly the difference between a bicornuate uterus that is really just arcuate or partially septate cannot always be made with ultrasound because the embryological defect is a relatively minor one. Ultrasound examination is able to give a lot of information in diagnosing and calculating how much of the menstrual fluid is held back either on one side or completely. Its value is less when the two sides of the uterus communicate with one another. Although this way of examining patients may make it possible quite often to avoid carrying out hysterosalpingogram and laparoscopy, its greatest value is found when all methods of diagnosis are combined and interpreted in the context of a clinical situation.

  7. Transvaginal ultrasound in threatened abortions with empty gestational sacs.

    PubMed

    Tongsong, T; Wanapirak, C; Srisomboon, J; Sirichotiyakul, S; Polsrisuthikul, T; Pongsatha, S

    1994-09-01

    To determine whether transvaginal ultrasound criteria alone can distinguish viable from non-viable gestational sacs at a single examination. A prospective descriptive study was undertaken and analysis performed on 211 pregnancies complicated by threatened abortion and empty gestation sacs diagnosed by transvaginal ultrasound. The main outcome measure was the final diagnosis of viable or non-viable gestation on subsequent transvaginal sonography. The study shows that a single transvaginal ultrasound examination is useful in differentiating viable from non-viable gestation sacs. The mean sac diameter (MSD) was found to be the most useful criterion for determining non-viability. An MSD of > or = 17 mm that lacked an embryo and an MSD of > or = 13 mm without visible yolk sac were reliable predictors of non-viable gestation sacs at a single examination with 100% specificity and 100% positive predictive value. An MSD > or = 13 mm without visible yolk sac was the most sensitive criterion. Using MSD criteria, 73% of non-viable gestations could be reliably identified without any false-positive diagnoses. Deformed shape, low position and thin decidual reaction are strong indicators of non-viable gestations but are not 100% accurate. There is still a significant proportion of empty sacs, where no accurate distinction between viable and non-viable can be made according to one criterion at a single examination and in these cases serial examinations should be carried out before any active management is advocated. In most cases, transvaginal sonographic criteria alone can distinguish viable from non-viable empty gestational sacs at a single examination.

  8. Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination.

    PubMed

    Stock, Konrad Friedrich; Klein, Bettina; Steubl, Dominik; Lersch, Christian; Heemann, Uwe; Wagenpfeil, Stefan; Eyer, Florian; Clevert, Dir-Andre

    2015-10-01

    Time savings and clinical accuracy of a new miniature ultrasound device was investigated utilizing comparison with conventional high-end ultrasound instruments. Our objective was to determine appropriate usage and limitations of this diagnostic tool in internal medicine. We investigated 28 patients from the internal-medicine department. Patients were examined with the Acuson P10 portable device and a Sonoline Antares instrument in a cross-over design. All investigations were carried out at the bedside; the results were entered on a standardized report form. The time for the ultrasound examination (transfer time, setting up and disassembly, switching on and off, and complete investigation time) was recorded separately. Mean time for overall examination per patient with the portable ultrasound device was shorter (25.0 ± 4.5 min) than with the high-end machine (29.4 ± 4.4 min; p < 0.001). When measuring the size of liver, spleen, and kidneys, the values obtained differed significantly between portable device and the high-end instrument. In our study, we identified 113 pathological ultrasound findings with the high-end ultrasound machine, while 82 pathological findings (73%) were concordantly detected with the portable ultrasound device. The main diagnostic strengths of the portable device were in the detection of ascites (sensitivity 80%), diagnosis of fatty liver, and identification of severe parenchymal liver damage. The clinical utility of portable ultrasound machines is limited. There will be clinical roles for distinct clinical questions such as detection of ascites or pleural effusion when used by experienced examiners. However, sensitivity in detecting multiple pathologies is not comparable to high-end ultrasound machines.

  9. Does endoscopic ultrasound improve detection of locally recurrent anal squamous-cell cancer?

    PubMed

    Peterson, Carrie Y; Weiser, Martin R; Paty, Philip B; Guillem, Jose G; Nash, Garrett M; Garcia-Aguilar, Julio; Patil, Sujata; Temple, Larissa K

    2015-02-01

    Evaluating patients for recurrent anal cancer after primary treatment can be difficult owing to distorted anatomy and scarring. Many institutions incorporate endoscopic ultrasound to improve detection, but the effectiveness is unknown. The aim of this study is to compare the effectiveness of digital rectal examination and endoscopic ultrasound in detecting locally recurrent disease during routine follow-up of patients with anal cancer. This study is a retrospective, single-institution review. This study was conducted at an oncologic tertiary referral center. Included were 175 patients with nonmetastatic anal squamous-cell cancer, without persistent disease after primary chemoradiotherapy, who had at least 1 posttreatment ultrasound and examination by a colorectal surgeon. The primary outcomes measured were the first modality to detect local recurrence, concordance, crude cancer detection rate, sensitivity, specificity, and predictive value. Eight hundred fifty-five endoscopic ultrasounds and 873 digital rectal examinations were performed during 35 months median follow-up. Overall, ultrasound detected 7 (0.8%) mesorectal and 32 (3.7%) anal canal abnormalities; digital examination detected 69 (7.9%) anal canal abnormalities. Locally recurrent disease was found on biopsy in 8 patients, all detected first or only with digital examination. Four patients did not have an ultrasound at the time of diagnosis of recurrence. The concordance of ultrasound and digital examination in detecting recurrent disease was fair at 0.37 (SE, 0.08; 95% CI, 0.21-0.54), and there was no difference in crude cancer detection rate, sensitivity, specificity, and negative or positive predictive values. The heterogeneity of follow-up timing and examinations is not standardized in this study but is reflective of general practice. Endoscopic ultrasound did not provide any advantage over digital rectal examination in identifying locally recurrent anal cancer, and should not be recommended for routine surveillance.

  10. Refixation of Osteochondral Fractures by an Ultrasound-Activated Pin System – An Ovine In Vivo Examination Using CT and Scanning Electron Microscope

    PubMed Central

    H, Neumann; A.P, Schulz; S, Breer; A, Unger; B, Kienast

    2015-01-01

    Background: Osteochondral injuries, if not treated appropriately, often lead to severe osteoarthritis of the affected joint. Without refixation of the osteochondral fragment, human cartilage only repairs these defects imperfectly. All existing refixation systems for chondral defects have disadvantages, for instance bad MRI quality in the postoperative follow-up or low anchoring forces. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants a higher anchoring is assumed. Aim of the study was to investigate, if ultrasound-activated pins can provide a secure refixation of osteochondral fractures comparing to conventional screw and conventional, resorbable pin osteosynthesis. CT scans and scanning electron microscopy should proovegood refixation results with no further tissue damage by the melting of the ultrasound-activated pins in comparison to conventional osteosynthesis. Methods: Femoral osteochondral fragments in sheep were refixated with ultrasound-activated pins (SonicPin™), Ethipins® and screws (Asnis™). The quality of the refixated fragments was examined after three month of full weight bearing by CT scans and scanning electron microscopy of the cartilage surface. Results: The CT examination found almost no statistically significant difference in the quality of refixation between the three different implants used. Concerning the CT morphology, ultrasound-activated pins demonstrated at least the same quality in refixation of osteochondral fragments as conventional resorbable pins or screws. The scanning electron microscopy showed no major surface damage by the three implants, especially any postulated cartilage damage induced by the heat of the ultrasound-activated pin. The screws protruded above the cartilage surface, which may affect the opposingtibial surface. Conclusion: Using CT scans and scanning electron microscopy, the SonicPin™, the Ethipin® and screws were at least equivalent in refixation quality of osteochondral fragments. PMID:25674184

  11. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia.

    PubMed

    Chen, Po-Hao; Slanetz, Priscilla J

    2014-01-01

    To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. A total of 353 mammograms were obtained from 327 unique patients (ages 18-95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Introduction of basic obstetrical ultrasound screening in undergraduate medical education.

    PubMed

    Hamza, A; Solomayer, E-F; Takacs, Z; Juhasz-Boes, I; Joukhadar, R; Radosa, J C; Mavrova, R; Marc, W; Volk, T; Meyberg-Solomayer, G

    2016-09-01

    Teaching ultrasound procedures to undergraduates has recently been proposed to improve the quality of medical education. We address the impact of applying standardized ultrasound teaching to our undergraduates. Medical students received an additional theoretical and practical course involving hands-on ultrasound screening during their mandatory practical training week in obstetrics and gynecology. The students' theoretical knowledge and fetal image recognition skills were tested before and after the course. After the course, the students were asked to answer a course evaluation questionnaire. To standardize the teaching procedure, we used Peyton's 4-Step Approach to teach the skills needed for a German Society of Ultrasound in Medicine Level 1 ultrasound examiner. The multiple-choice question scores after the course showed statistically significant improvement (50 vs. 80 %; P < 0.001). The questionnaire revealed that students were satisfied with the course, felt that it increased their ultrasound knowledge, and indicated that they wanted more sonographic hands-on training in both obstetrics and gynecology and other medical fields. Using practical, hands-on medical teaching is an emerging method for undergraduate education that should be further evaluated, standardized, and developed.

  13. Ultrasonic effects on titanium tanning of leather.

    PubMed

    Peng, Biyu; Shi, Bi; Sun, Danhong; Chen, Yaowen; Shelly, Dennis C

    2007-03-01

    The effects of ultrasound on titanium tanning of leather were investigated. Either 20 or 40 kHz ultrasound was applied to the titanium tanning of pigskins. Five different treatment conditions were carried out and the effects were examined, such as leather shrinkage temperature (T(s)), titanium content and titanium distribution in the leather. Overall heat loading was carefully controlled. Results showed that 20 kHz ultrasound effectively improves titanium agent penetration into the hide and increases the leather's shrinkage temperature. Doubling the frequency to 40 kHz produced negligible enhancements. An impressive 105.6 degrees C T(s) was achieved using 20 kHz ultrasound pretreatment of the tanning liquor followed by 20 kHz ultrasound in the tanning mixture (liquor plus pigskins) in a special salt-free medium. Finally, using a unique ultrasonic tanning drum with 26.5 kHz ultrasound, the T(s) reached a record level of 106.5 degrees C, a value not achieved in conventional (no ultrasound) titanium tanning. The ultrasonic effects on titanium tanning of leather are judged to make a superior mineral tanned leather.

  14. Time course of VMN lesion effects on lordosis and proceptive behavior in female hamsters.

    PubMed

    Floody, Owen R

    2002-06-01

    Previous studies suggest that ultrasound production by female hamsters is better able than other reproductive behaviors to recover from an initial drop caused by damage to the ventromedial hypothalamus (VMN). At the same time, few studies have examined the time course of such lesion effects. To remedy this, female hamsters were observed before and after control operations or VMN lesions. The behaviors considered were ultrasound production, lordosis, approach, and vaginal marking. Ultrasound production, lordosis, and approach were affected by lesions, permitting the description of the time course of each of these effects. Only ultrasound rates showed evidence of recovery, which culminated in rates significantly above those observed preoperatively in the same animals. This suggests that ultrasound production is unusual in its response to VMN damage and that the underlying mechanism could be of interest in studies of the processes that determine recovery from brain damage. (c) 2002 Elsevier Science (USA).

  15. Evaluation of trainees' ability to perform obstetrical ultrasound using simulation: challenges and opportunities.

    PubMed

    Chalouhi, Gihad E; Bernardi, Valeria; Gueneuc, Alexandra; Houssin, Isabelle; Stirnemann, Julien J; Ville, Yves

    2016-04-01

    Evaluation of trainee's ability in obstetrical ultrasound is a time-consuming process, which requires involving patients as volunteers. With the use of obstetrical ultrasound simulators, virtual reality could help in assessing competency and evaluating trainees in this field. The objective of the study was to test the validity of an obstetrical ultrasound simulator as a tool for evaluating trainees following structured training by comparing scores obtained on obstetrical ultrasound simulator with those obtained on volunteers and by assessing correlations between scores of images and of dexterity given by 2 blinded examiners. Trainees, taking the 2013 French national examination for the practice of obstetrical ultrasound were asked to obtain standardized ultrasound planes both on volunteer pregnant women and on an obstetrical ultrasound simulator. These planes included measurements of biparietal diameter, abdominal circumference, and femur length as well as reference planes for cardiac 4-chamber and outflow tracts, kidneys, stomach/diaphragm, spine, and face. Images were stored and evaluated subsequently by 2 national examiners who scored each picture according to previously established quality criteria. Dexterity was also evaluated and subjectively scored between 0 and 10. The Raghunathan's modification of Pearson, Filon's z, Spearman's rank correlation, and analysis of variance tests were used to assess correlations between the scores by the 2 examiners and scores of dexterity and also to compare the final scores between the 2 different methods. We evaluated 29 trainees. The mean dexterity scores in simulation (6.5 ± 2.0) and real examination (5.9 ± 2.3) were comparable (P = .31). Scores with an obstetrical ultrasound simulator were significantly higher than those obtained on volunteers (P = .027). Nevertheless, there was a good correlation between the scores of the 2 examiners judging on simulation (R = 0.888) and on volunteers (R = 0.873) (P = .81). An obstetrical ultrasound simulator is as good a method as volunteer-based examination for evaluating practical skills in trainees following structured training in obstetrical ultrasound. The threshold for success/failure should, however, be adapted as candidates obtain higher scores on the simulator. Advantages of the obstetrical ultrasound simulator include the absence of location and time constraints without the need to involve volunteers or to interfere with the running of ultrasound clinics. However, an obstetrical ultrasound simulator still lacks the ability to evaluate the trainees' ability to interact with patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Differences in Multi-Modal Ultrasound Imaging between Triple Negative and Non-Triple Negative Breast Cancer.

    PubMed

    Li, Ziyao; Tian, Jiawei; Wang, Xiaowei; Wang, Ying; Wang, Zhenzhen; Zhang, Lei; Jing, Hui; Wu, Tong

    2016-04-01

    The objective of this study was to identify multi-modal ultrasound imaging parameters that could potentially help to differentiate between triple negative breast cancer (TNBC) and non-TNBC. Conventional ultrasonography, ultrasound strain elastography and 3-D ultrasound (3-D-US) findings from 50 TNBC and 179 non-TNBC patients were retrospectively reviewed. Immunohistochemical examination was used as the reference gold standard for cancer subtyping. Different ultrasound modalities were initially analyzed to define TNBC-related features. Subsequently, logistic regression analysis was applied to TNBC-related features to establish models for predicting TNBC. TNBCs often presented as micro-lobulated, markedly hypo-echoic masses with an abrupt interface (p = 0.015, 0.0015 and 0.004, compared with non-TNBCs, respectively) on conventional ultrasound, and showed a diminished retraction pattern phenomenon in the coronal plane (p = 0.035) on 3-D-US. Our findings suggest that B-mode ultrasound and 3-D-US in multi-modality ultrasonography could be a useful non-invasive technique for differentiating TNBCs from non-TNBCs. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Point-of-Care Ultrasound: A Trend in Health Care.

    PubMed

    Buerger, Anita M; Clark, Kevin R

    2017-11-01

    To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.

  18. Ocular examination for trauma; clinical ultrasound aboard the International Space Station.

    PubMed

    Chiao, Leroy; Sharipov, Salizhan; Sargsyan, Ashot E; Melton, Shannon; Hamilton, Douglas R; McFarlin, Kellie; Dulchavsky, Scott A

    2005-05-01

    Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using remote guidance. Ocular ultrasound images were of diagnostic quality despite the 2-second communication latency and the unconventional setting of a weightless spacecraft environment. The remote guidance techniques developed to facilitate this successful NASA research experiment will support wider applications of ultrasound for remote medicine on Earth including the assessment of pupillary reactions in patients with severe craniofacial trauma and swelling.

  19. Ocular examination for trauma; clinical ultrasound aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Chiao, Leroy; Sharipov, Salizhan; Sargsyan, Ashot E.; Melton, Shannon; Hamilton, Douglas R.; McFarlin, Kellie; Dulchavsky, Scott A.

    2005-01-01

    BACKGROUND: Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. METHODS: An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. RESULTS: A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. CONCLUSIONS: A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using remote guidance. Ocular ultrasound images were of diagnostic quality despite the 2-second communication latency and the unconventional setting of a weightless spacecraft environment. The remote guidance techniques developed to facilitate this successful NASA research experiment will support wider applications of ultrasound for remote medicine on Earth including the assessment of pupillary reactions in patients with severe craniofacial trauma and swelling.

  20. High-intensity focused ultrasound ablation of thyroid nodules: first human feasibility study.

    PubMed

    Esnault, Olivier; Franc, Brigitte; Ménégaux, Fabrice; Rouxel, Agnès; De Kerviler, Eric; Bourrier, Pierre; Lacoste, François; Chapelon, Jean-Yves; Leenhardt, Laurence

    2011-09-01

    Thyroid surgery is common, but complications may occur. High-intensity focused ultrasound (HIFU) is a minimally invasive alternative to surgery. We hypothesized that an optimized HIFU device could be safe and effective for ablating benign thyroid nodules without affecting neighboring structures. In this open, single-center feasibility study, 25 patients were treated with HIFU with real-time ultrasound imaging 2 weeks before a scheduled thyroidectomy for multinodular goiter. Thyroid ultrasonography imaging, thyroid function, were evaluated before and after treatment. Adverse events were carefully recorded. Each patient received HIFU for one thyroid nodule, solid or mixed, with mean diameter ≥8 mm, and no suspicion of malignancy. The HIFU device was progressively adjusted with stepwise testing. The energy level for ablation ranged from 35 to 94 J/pulse for different groups of patients. One pathologist examined all removed thyroids. Three patients discontinued treatment due to pain or skin microblister. Among the remaining 22 patients, 16 showed significant changes by ultrasound. Macroscopic and histological examinations showed that all lesions were confined to the targeted nodule without affecting neighboring structures. At pathological analysis, the extent of nodule destruction ranged from 2% to 80%. Five out of 22 patients had over 20% pathological lesions unmistakably attributed to HIFU. Seventeen cases had putative lesions including nonspecific necrosis, hemorrhage, nodule detachment, cavitations, and cysts. Among these 17 cases, 12 had both ultrasound changes and cavitation at histology that may be expected for an HIFU effect. In the last three patients ablated at the highest energy level, significant ultrasound changes and complete coagulative necrosis were observed in 80%, 78%, and 58% of the targeted area, respectively. There were no major complications of ablation. This study showed the potential efficacy of HIFU for human thyroid nodule ablation. Lesions were clearly visible by histology and ultrasound after high energy treatments, and safety and tolerability were good. We identified a power threshold for optimal necrosis of the target thyroid tissue. Further studies are ongoing to assess nodule changes at longer follow-up times.

  1. Correlates of mammographic density in B-mode ultrasound and real time elastography.

    PubMed

    Jud, Sebastian Michael; Häberle, Lothar; Fasching, Peter A; Heusinger, Katharina; Hack, Carolin; Faschingbauer, Florian; Uder, Michael; Wittenberg, Thomas; Wagner, Florian; Meier-Meitinger, Martina; Schulz-Wendtland, Rüdiger; Beckmann, Matthias W; Adamietz, Boris R

    2012-07-01

    The aim of our study involved the assessment of B-mode imaging and elastography with regard to their ability to predict mammographic density (MD) without X-rays. Women, who underwent routine mammography, were prospectively examined with additional B-mode ultrasound and elastography. MD was assessed quantitatively with a computer-assisted method (Madena). The B-mode and elastography images were assessed by histograms with equally sized gray-level intervals. Regression models were built and cross validated to examine the ability to predict MD. The results of this study showed that B-mode imaging and elastography were able to predict MD. B-mode seemed to give a more accurate prediction. R for B-mode image and elastography were 0.67 and 0.44, respectively. Areas in the B-mode images that correlated with mammographic dense areas were either dark gray or of intermediate gray levels. Concerning elastography only the gray levels that represent extremely stiff tissue correlated positively with MD. In conclusion, ultrasound seems to be able to predict MD. Easy and cheap utilization of regular breast ultrasound machines encourages the use of ultrasound in larger case-control studies to validate this method as a breast cancer risk predictor. Furthermore, the application of ultrasound for breast tissue characterization could enable comprehensive research concerning breast cancer risk and breast density in young and pregnant women.

  2. Ultrasound Findings in Tension Pneumothorax: A Case Report.

    PubMed

    Inocencio, Maxine; Childs, Jeannine; Chilstrom, Mikaela L; Berona, Kristin

    2017-06-01

    Delayed recognition of tension pneumothorax can lead to a mortality of 31% to 91%. However, the classic physical examination findings of tracheal deviation and distended neck veins are poorly sensitive in the diagnosis of tension pneumothorax. Point-of-care ultrasound is accurate in identifying the presence of pneumothorax, but sonographic findings of tension pneumothorax are less well described. We report the case of a 21-year-old man with sudden-onset left-sided chest pain. He was clinically stable without hypoxia or hypotension, and the initial chest x-ray study showed a large pneumothorax without mediastinal shift. While the patient was awaiting tube thoracostomy, a point-of-care ultrasound demonstrated findings of mediastinal shift and a dilated inferior vena cava (IVC) concerning for tension physiology, even though the patient remained hemodynamically stable. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case demonstrates a unique clinical scenario of ultrasound evidence of tension physiology in a clinically stable patient. Although this patient was well appearing without hypotension, respiratory distress, tracheal deviation, or distended neck veins, point-of-care ultrasound revealed mediastinal shift and a plethoric IVC. Given that the classic clinical signs of tension pneumothorax are not uniformly present, this case shows how point-of-care ultrasound may diagnose tension pneumothorax before clinical decompensation. Published by Elsevier Inc.

  3. Development of transducer arrays for ultrasound-computer tomography

    NASA Astrophysics Data System (ADS)

    Stotzka, Rainer; Gobel, Georg; Schlote-Holubek, Klaus

    2003-05-01

    Ultrasound computer-tomography (USCT) is a novel ultrasound imaging method capable of producing volume images with both high spatial and temporal resolution. Several thousand ultrasound transducers are arranged in a cylindrical array around a tank containing the object to be examined coupled by water. Every single transducer is small enough to emit an almost spherical sound-wave. While one transducer is transmitting, all others receive simultaneously. Our experimental setup, using only a few transducers simulating a ring-shaped geometry, showed even nylon threads (0.1 mm) with an image quality superior to clinical in-use ultrasound scanners. In order to build a complete circular array several thousand transducers, with cylindrical sound field characteristics, are needed. Since such transducer arrays are hardly available and expensive, we developed inexpensive transducer arrays consisting of 8 elements. Each array is based on a plate of lead titanate zirconate ceramics (PZT) sawn into 8 elements of 0.3 mm width, 3.8 mm height and 0.5 mm pitch. Each element has a mean frequency of 3.8 MHz and can be triggered separately. The main challenge was the development of production steps with reproducible results. Our transducer arrays show only small variances in the sound field characteristics which are strongly required for ultrasound tomography.

  4. In Vivo Demonstration of Cancer Molecular Imaging with Ultrasound Radiation Force and Buried-Ligand Microbubbles

    PubMed Central

    Borden, Mark A.; Streeter, Jason E.; Sirsi, Shashank R.; Dayton, Paul A.

    2015-01-01

    In designing targeted contrast agent materials for imaging, the need to present a targeting ligand for recognition and binding by the target is counterbalanced by the need to minimize interactions with plasma components and to avoid recognition by the immune system. We have previously reported on a microbubble imaging probe for ultrasound molecular imaging that uses a buried-ligand surface architecture to minimize unwanted interactions and immunogenicity. Here we examine for the first time the utility of this approach for in vivo molecular imaging. In accordance with previous results, we showed a threefold increase in circulation persistence through the tumor of a fibrosarcoma model in comparison with controls. The buried-ligand microbubbles were then activated for targeted adhesion through the application of noninvasive ultrasound radiation forces applied specifically to the tumor region. Using a clinical ultrasound scanner, microbubbles were activated, imaged, and silenced. The results showed visually conspicuous images of tumor neovasculature and a twofold increase in ultrasound radiation force enhancement of acoustic contrast intensity for buried-ligand microbubbles, whereas no such increase was found for exposed-ligand microbubbles. We therefore conclude that the use of acoustically active buried-ligand microbubbles for ultrasound molecular imaging bridges the demand for low immunogenicity with the necessity of maintaining targeting efficacy and imaging conspicuity in vivo. PMID:23981781

  5. Validity of gestational age estimates by last menstrual period and neonatal examination compared to ultrasound in Vietnam.

    PubMed

    Deputy, Nicholas P; Nguyen, Phuong H; Pham, Hoa; Nguyen, Son; Neufeld, Lynnette; Martorell, Reynaldo; Ramakrishnan, Usha

    2017-01-11

    Accurate estimation of gestational age is important for both clinical and public health purposes. Estimates of gestational age using fetal ultrasound measurements are considered most accurate but are frequently unavailable in low- and middle-income countries. The objective of this study was to assess the validity of last menstrual period and Farr neonatal examination estimates of gestational age, compared to ultrasound estimates, in a large cohort of women in Vietnam. Data for this analysis come from a randomized, placebo-controlled micronutrient supplementation trial in Vietnam. We analyzed 912 women with ultrasound and prospectively-collected last menstrual period estimates of gestational age and 685 women with ultrasound and Farr estimates of gestational age. We used the Wilcoxon signed rank sum test to assess differences in gestational age estimated by last menstrual period or Farr examination compared to ultrasound and computed the intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC) to quantify agreement between methods. We computed the Kappa coefficient (κ) to quantify agreement in preterm, term and post-term classification. The median gestational age estimated by ultrasound was 273.9 days. Gestational age was slightly overestimated by last menstrual period (median 276.0 days, P < 0.001) and more greatly overestimated by Farr examination (median 286.7 days, P < 0.001). Gestational age estimates by last menstrual period and ultrasound were moderately correlated (ICC = 0.78) and concordant (CCC = 0.63), whereas gestational age estimates by Farr examination and ultrasound were weakly correlated (ICC = 0.26) and concordant (CCC = 0.05). Last menstrual period and ultrasound estimates of gestational age were within ± 14 days for 88.4% of women; Farr and ultrasound estimates were within ± 14 days for 55.8% of women. Last menstrual period and ultrasound estimates of gestational age had higher agreement in term classification (κ = 0.41) than Farr and ultrasound (κ = 0.05). In this study of women in Vietnam, we found last menstrual period provided a more accurate estimate of gestational age than the Farr examination when compared to ultrasound. These findings provide useful information about the utility and accuracy of different methods to estimate gestational age and suggest last menstrual period may be preferred over Farr examination in settings where ultrasound is unavailable. The trial was registered at ClinicalTrials.Gov as NCT01665378 on August 13, 2012.

  6. Adding New Tools to the Black Bag—Introduction of Ultrasound into the Physical Diagnosis Course

    PubMed Central

    Amponsah, David; Yang, James; Mendez, Jennifer; Bridge, Patrick; Hays, Gregory; Baliga, Sudhir; Crist, Karen; Brennan, Simone; Jackson, Matt; Dulchavsky, Scott

    2010-01-01

    INTRODUCTION Ultrasound, a versatile diagnostic modality that permits real-time visualization at the patient’s bedside, can be used as an adjunct in teaching physical diagnosis (PD). Aims: (1) to study the feasibility of incorporating ultrasound into PD courses and (2) determine whether learners can demonstrate image recognition and acquisition skills. PROGRAM DESCRIPTION Three hundred seven second-year medical students were introduced to cardiovascular and abdominal ultrasound scanning after training in the physical examination. This consisted of a demonstration of the ultrasound examination, followed by practice on standardized patients (SPs). Pre-post tests were administered to evaluate students’ knowledge and understanding of ultrasound. Students performed an ultrasound examination during the PD final examination. PROGRAM EVALUATION Pre-post test data revealed significant improvements in image recognition. On the final exam, the highest scores (98.4%) were obtained for the internal jugular vein and lowest scores (74.6%) on the Focused Assessment with Sonography for Trauma images. Eighty-nine percent of students’ surveyed felt ultrasound was a valuable tool for physicians. DISCUSSION An introductory ultrasound course is effective in improving medical students' acquisition and recognition of basic cardiovascular and abdominal ultrasound images. This innovative program demonstrates the feasibility of incorporating portable ultrasound as a learning tool during medical school. Electronic supplementary material The online version of this article (doi:10.1007/s11606-010-1451-5) contains supplementary material, which is available to authorized users. PMID:20697974

  7. Ultrasound detection of placenta accreta in the first trimester of pregnancy

    PubMed Central

    Rahimi-Sharbaf, Fatemeh; Jamal, Ashraf; Mesdaghinia, Elaheh; Abedzadeh- Kalahroudi, Masoumeh; Niroomanesh, Shirin; Atoof, Fatemeh

    2014-01-01

    Background: Placenta accreta is considered a life-threatening condition and the main cause of maternal mortality. Prenatal diagnosis of placenta accreta usually is made by clinical presentation, imaging studies like ultrasound and MRI in the second and third trimester. Objective: To determine accuracy of ultrasound findings for placenta accreta in the first trimester of pregnancy. Materials and Methods: In a longitudinal study 323 high risk patients for placenta accreta were assessed. The eligible women were examined by vaginal and abdominal ultrasound for gestational sac and placental localization and they were followed up until the end of pregnancy. The ultrasound findings were compared with histopathological examinations as a gold standard. The sensitivity, specificity, positive and negative predictive value of ultrasound were estimated for the first trimester and compared with other 2 trimesters in the case of repeated ultrasound examination. Results: Ultrasound examinations in the first trimester revealed that 28 cases had the findings in favor of placenta accreta which ultimately was confirmed in 7 cases. The ultrasound sensitivity and specificity for detecting placenta accreta in the first trimester was 41% [95% CI: 16.2-62.7] and 88% [95% CI: 88.2-94.6] respectively. Conclusion: Ultrasound screening for placenta accreta in the first trimester of pregnancy could not achieve the high sensitivity as second and third trimester of pregnancy. PMID:25071851

  8. Remote just-in-time telementored trauma ultrasound: a double-factorial randomized controlled trial examining fluid detection and remote knobology control through an ultrasound graphic user interface display.

    PubMed

    Kirkpatrick, Andrew W; McKee, Ian; McKee, Jessica L; Ma, Irene; McBeth, Paul B; Roberts, Derek J; Wurster, Charles L; Parfitt, Robbie; Ball, Chad G; Oberg, Scott; Sevcik, William; Hamilton, Douglas R

    2016-05-01

    Remote-telementored ultrasound involves novice examiners being remotely guided by experts using informatic-technologies. However, requiring a novice to perform ultrasound is a cognitively demanding task exacerbated by unfamiliarity with ultrasound-machine controls. We incorporated a randomized evaluation of using remote control of the ultrasound functionality (knobology) within a study in which the images generated by distant naive examiners were viewed on an ultrasound graphic user interface (GUI) display viewed on laptop computers by mentors in different cities. Fire-fighters in Edmonton (101) were remotely mentored from Calgary (n = 65), Nanaimo (n = 19), and Memphis (n = 17) to examine an ultrasound phantom randomized to contain free fluid or not. Remote mentors (2 surgeons, 1 internist, and 1 ED physician) were randomly assigned to use GUI knobology control during mentoring (GUIK+/GUIK-). Remote-telementored ultrasound was feasible in all cases. Overall accuracy for fluid detection was 97% (confidence interval = 91 to 99%) with 3 false negatives (FNs). Positive/negative likelihood ratios were infinity/0.0625. One FN occurred with the GUIK+ and 2 without (GUIK-). There were no statistical test performance differences in either group (GUIK+ and GUIK-). Ultrasound-naive 1st responders can be remotely mentored with high accuracy, although providing basic remote control of the knobology did not affect outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Clinical Utility of High-Frequency Musculoskeletal Ultrasonography in Foot and Ankle Pathology: How Ultrasound Imaging Influences Diagnosis and Management.

    PubMed

    Delzell, Patricia B; Tritle, Benjamin A; Bullen, Jennifer A; Chiunda, Stella; Forney, Michael C

    The use of high-frequency (high-resolution) musculoskeletal ultrasonography is increasing and has shown promising utility in many areas of medicine. The utility of musculoskeletal ultrasonography for foot and ankle complaints has not been widely investigated, however. Although some conditions of the foot and ankle are easily diagnosed by physical examination, others can have nonspecific examination findings, making optimal treatment decisions difficult. We hypothesized that high-resolution musculoskeletal ultrasound scanning of the foot and ankle can affect the diagnosis and/or treatment for patients presenting with foot or ankle complaints. Retrospectively, the cases of 98 patients who had undergone musculoskeletal ultrasound scanning of the foot or ankle were reviewed. The pre-ultrasound clinical diagnosis and treatment were compared with the post-ultrasound diagnosis and treatment. In 64% of the patients, the diagnosis or treatment changed after the ultrasound examination. In 43% of patients, both the diagnosis and the treatment changed after ultrasound scanning. For those patients for whom the diagnosis and treatment were unchanged after the ultrasound examination, the ultrasound findings were concordant with the pre-ultrasound clinical diagnosis for 100% of the patients. These results suggest that in a large proportion of patients, high-resolution musculoskeletal ultrasonography of the foot or ankle can facilitate appropriate diagnosis and management. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. First trimester diagnosis of parapagus diprosopus dibrachius dipus twins with cranirachischisis totalis by three-dimensional ultrasound.

    PubMed

    Ülker, Kahraman; Akyer, Şahika P; Temur, İsmail; Tan, Temel; Karaca, Mehmet; Adıgüzel, Esat; Gül, Abdülaziz

    2012-02-01

    Parapagus (laterally fused), diprosopus (two faces), dibrachius (two upper extremities), dipus (two lower extremities) conjoined twinning is extremely rare. The coexistence of anencephaly with a contiguous spinal defect (craniorachischisis totalis) makes the present case one of the rarest of the published cases. In our case, it was difficult to make the final diagnosis by two-dimensional abdominal and vaginal ultrasound. Three-dimensional ultrasound was helpful for final diagnosis and post-abortal examination confirmed the prenatal ultrasound diagnosis. The heart, diaphragm, liver and perineum were all united. Fine dissection of the heart showed four vessels arising from the ventricles and a membranous type ventricular septal defect. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.

  11. Cognitive load imposed by ultrasound-facilitated teaching does not adversely affect gross anatomy learning outcomes.

    PubMed

    Jamniczky, Heather A; Cotton, Darrel; Paget, Michael; Ramji, Qahir; Lenz, Ryan; McLaughlin, Kevin; Coderre, Sylvain; Ma, Irene W Y

    2017-03-01

    Ultrasonography is increasingly used in medical education, but its impact on learning outcomes is unclear. Adding ultrasound may facilitate learning, but may also potentially overwhelm novice learners. Based upon the framework of cognitive load theory, this study seeks to evaluate the relationship between cognitive load associated with using ultrasound and learning outcomes. The use of ultrasound was hypothesized to facilitate learning in anatomy for 161 novice first-year medical students. Using linear regression analyses, the relationship between reported cognitive load on using ultrasound and learning outcomes as measured by anatomy laboratory examination scores four weeks after ultrasound-guided anatomy training was evaluated in consenting students. Second anatomy examination scores of students who were taught anatomy with ultrasound were compared with historical controls (those not taught with ultrasound). Ultrasound's perceived utility for learning was measured on a five-point scale. Cognitive load on using ultrasound was measured on a nine-point scale. Primary outcome was the laboratory examination score (60 questions). Learners found ultrasound useful for learning. Weighted factor score on "image interpretation" was negatively, but insignificantly, associated with examination scores [F (1,135) = 0.28, beta = -0.22; P = 0.61]. Weighted factor score on "basic knobology" was positively and insignificantly associated with scores; [F (1,138) = 0.27, beta = 0.42; P = 0.60]. Cohorts exposed to ultrasound had significantly higher scores than historical controls (82.4% ± SD 8.6% vs. 78.8% ± 8.5%, Cohen's d = 0.41, P < 0.001). Using ultrasound to teach anatomy does not negatively impact learning and may improve learning outcomes. Anat Sci Educ 10: 144-151. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  12. ARFI-based tissue elasticity quantification and kidney graft dysfunction: first clinical experiences.

    PubMed

    Stock, K F; Klein, B S; Cong, M T Vo; Regenbogen, C; Kemmner, S; Büttner, M; Wagenpfeil, S; Matevossian, E; Renders, L; Heemann, U; Küchle, C

    2011-01-01

    Beyond the medical history, the clinical exam and lab findings, non-invasive ultrasound parameters such as kidney size and Doppler values (e.g. the resistive index) are important tools assisting clinical decision making in the monitoring of renal allografts. The gold standard for the diagnosis of renal allograft dysfunction remains the renal biopsy; while an invasive procedure, the justifiable necessity for this derives from its definitive nature a requirement beyond the synopses of all non-invasive tools. "Acoustic Radiation Force Impulse Imaging"(ARFI)-quantification is a novel ultrasound-based technology measuring tissue elasticity properties. So far experience related to this new method has not been reported in renal transplant follow-up. The purpose of this study was to evaluate changes in ARFI-measurements between clinically stable renal allografts and biopsy-proven transplant dysfunction. We employed "Virtual Touch™ tissue quantification" (Siemens Acuson, S2000) for the quantitative measurement of tissue stiffness in the cortex of transplant kidneys. We performed initial baseline and later disease-evaluative ultrasound examinations in 8 renal transplant patients in a prospective study design. Patients were first examined during stable allograft function with a routine post-transplant renal ultrasound protocol. A second follow-up examination was carried out on subsequent presentation with transplant dysfunction prior to allograft biopsy and histological evaluation. All patiens were examined using ARFI-quantification (15 measurements/kidney). Resistive indices (RI) were calculated using pulsed-wave Doppler ultrasound, and transplant kidney size was measured on B-mode ultrasound images. All biopsies were evaluated histologically by a reference nephropathologist unaware of the results of the ultrasound studies. Histopathological diagnoses were based on biopsy results, taking clinical and laboratory findings into account. Finally we calculated the relative changes in ARFI-quantification, resistive indices and the absolute change of kidney size on a percentage basis at these defined assessment times and compared the results with the final pathologic diagnosis. Histological results enumerated five cases of acute T-cell-mediated rejection, one case of calcineurin inhibitor toxicity and two cases of acute tubular necrosis. Calcineurin inhibitor toxicity and acute tubular necrosis were subsumed as "other pathologies". Mean ARFI-values showed an average increase of more than 15% percent in transplants with histologically proven acute rejection whereas no increase was seen in transplants with other pathologies. Mean RI-values showed no increase either in the diagnostic group of acute rejection, nor in the group with other pathologies. Kidney size showed a mean absolute increase of 0.5 centimetres in allografts with acute rejection, whereas a mean decrease of 0.17 centimetres was seen in the group with other pathologies. As shown before in other studies, RI values and kidney size are of doubtful utility in the evaluation of kidney allograft dysfunction. ARFI-based elasticity measurement shows promise as a complementary non-invasive parameter in follow-on diagnosis of renal allograft rejection.

  13. New heights in ultrasound: first report of spinal ultrasound from the international space station.

    PubMed

    Marshburn, Thomas H; Hadfield, Chris A; Sargsyan, Ashot E; Garcia, Kathleen; Ebert, Douglas; Dulchavsky, Scott A

    2014-01-01

    Changes in the lumbar and sacral spine occur with exposure to microgravity in astronauts; monitoring these alterations without radiographic capabilities on the International Space Station (ISS) requires novel diagnostic solutions to be developed. We evaluated the ability of point-of-care ultrasound, performed by nonexpert-operator astronauts, to provide accurate anatomic information about the spine in long-duration crewmembers in space. Astronauts received brief ultrasound instruction on the ground and performed in-flight cervical and lumbosacral ultrasound examinations using just-in-time training and remote expert tele-ultrasound guidance. Ultrasound examinations on the ISS used a portable ultrasound device with real-time communication/guidance with ground experts in Mission Control. The crewmembers were able to obtain diagnostic-quality examinations of the cervical and lumbar spine that would provide essential information about acute or chronic changes to the spine. Spinal ultrasound provides essential anatomic information in the cervical and lumbosacral spine; this technique may be extensible to point-of-care situations in emergency departments or resource-challenged areas without direct access to additional radiologic capabilities. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Phased Array Ultrasound: Initial Development of PAUT Inspection of Self-Reacting Friction Stir Welds

    NASA Technical Reports Server (NTRS)

    Rairigh, Ryan

    2008-01-01

    This slide presentation reviews the development of Phased Array Ultrasound (PAUT) as a non-destructive examination method for Self Reacting Friction Stir Welds (SR-FSW). PAUT is the only NDE method which has been shown to detect detrimental levels of Residual Oxide Defect (ROD), which can result in significant decrease in weld strength. The presentation reviews the PAUT process, and shows the results in comparison with x-ray radiography.

  15. Ultrasound-Diagnosed Tibia Stress Fracture: A Case Report.

    PubMed

    Amoako, Adae; Abid, Ayesha; Shadiack, Anthony; Monaco, Robert

    2017-01-01

    Stress fractures are a frequent cause of lower extremity pain in athletes, and especially in runners. Plain imaging has a low sensitivity. Magnetic resonance imaging (MRI) or bone scan scintigraphy is the criterion standard, but expensive. We present the case of a young female distance runner with left shin pain. Plain radiography was unremarkable. Ultrasound showed focal hyperechoic elevation of the periosteum with irregularity over the distal tibia and increased flow on Doppler. These findings were consistent with a distal tibia stress fracture and confirmed by MRI. Examination of our case will highlight the utility of considering an ultrasound for diagnosis of tibial stress fracture.

  16. Ultrasound-Diagnosed Tibia Stress Fracture: A Case Report

    PubMed Central

    Amoako, Adae; Abid, Ayesha; Shadiack, Anthony; Monaco, Robert

    2017-01-01

    Stress fractures are a frequent cause of lower extremity pain in athletes, and especially in runners. Plain imaging has a low sensitivity. Magnetic resonance imaging (MRI) or bone scan scintigraphy is the criterion standard, but expensive. We present the case of a young female distance runner with left shin pain. Plain radiography was unremarkable. Ultrasound showed focal hyperechoic elevation of the periosteum with irregularity over the distal tibia and increased flow on Doppler. These findings were consistent with a distal tibia stress fracture and confirmed by MRI. Examination of our case will highlight the utility of considering an ultrasound for diagnosis of tibial stress fracture. PMID:28469488

  17. Role of ultrasound in colorectal diseases.

    PubMed

    Bor, Renáta; Fábián, Anna; Szepes, Zoltán

    2016-11-21

    Ultrasound is an undervalued non-invasive examination in the diagnosis of colonic diseases. It has been replaced by the considerably more expensive magnetic resonance imaging and computed tomography, despite the fact that, as first examination, it can usefully supplement the diagnostic process. Transabdominal ultrasound can provide quick information about bowel status and help in the choice of adequate further examinations and treatment. Ultrasonography, as a screening imaging modality in asymptomatic patients can identify several colonic diseases such as diverticulosis, inflammatory bowel disease or cancer. In addition, it is widely available, cheap, non-invasive technique without the use of ionizing radiation, therefore it is safe to use in childhood or during pregnancy, and can be repeated at any time. New ultrasound techniques such as elastography, contrast enhanced and Doppler ultrasound, mini-probes rectal and transperineal ultrasonography have broadened the indication. It gives an overview of the methodology of various ultrasound examinations, presents the morphology of normal bowel wall and the typical changes in different colonic diseases. We will pay particular attention to rectal and transperineal ultrasound because of their outstanding significance in the diagnosis of rectal and perineal disorders. This article seeks to overview the diagnostic impact and correct indications of bowel ultrasound.

  18. Evaluating Didactic Methods for Training Medical Students in the Use of Bedside Ultrasound for Clinical Practice at a Faculty of Medicine in Romania.

    PubMed

    Florescu, Cosmin C; Mullen, Jeffrey A; Nguyen, Vivian My; Sanders, Brooke E; Vu, Priscilla Quynh-Phuon

    2015-10-01

    Medical students' time is limited, so efficiency in medical education is valued. This research project aimed to determine the most effective means to teach bedside ultrasound to medical students in a 1-week training course. We hypothesized that the best method would include a combination of podcasts and hands-on teaching; therefore, there would be a statistically significant difference among the various methods of teaching. Medical students were randomly assigned to 3 groups. All groups attended a 50-minute hands-on bedside ultrasound training session. Students in the first group attended a 50-minute live lecture before the hands-on session, whereas students in the second group watched a podcast that covered the same material as the live lecture. Students in the third group served as the control and only attended the hands-on sessions. Five topics were covered during the course: (1) introduction to ultrasound, (2) pulmonary ultrasound, (3) cardiac ultrasound, (4) hepatobiliary ultrasound, and (5) focused assessment with sonography for trauma. Students completed a 20-question pre- and post-training quiz that covered basic ultrasound principles. Students also conducted a focused assessment with sonography for trauma examination for the practical portion of their evaluation. Students' pre- to post-training quiz scores increased from 33.6% to 72.6% correct in the lecture group (n = 21; P < .0001), from 40.7% to 75.5% correct in the podcast group (n = 20; P< .0001), and from 37.8% to 70.0% correct in the control group (n = 23; P< .0001). Data analysis of written and practical examination scores showed no significant differences among the groups [F(2,61) = 0.885; P = .418; F(2,60) = 1.739; P = .184, respectively]. These results suggest that all 3 methods are equally effective in teaching novice medical students basic ultrasound knowledge and skills. © 2015 by the American Institute of Ultrasound in Medicine.

  19. Safety of Microbubbles and Transcranial Ultrasound in Rabbits

    NASA Astrophysics Data System (ADS)

    Culp, William C.; Brown, Aliza T.; Hennings, Leah; Lowery, John; Culp, Benjamin C.; Erdem, Eren; Roberson, Paula; Matsunaga, Terry O.

    2007-05-01

    The object of this study was to evaluate the safety of large doses of microbubbles and ultrasound administered to the head of rabbits as if they were receiving acute stroke therapy of a similar nature. Materials and Methods: Female New Zealand White rabbits were used, N=24, in three groups 1] n=4 control (no treatment), 2] n=10 bubble control (ultrasound plus aspirin), and 3] n=10 target group (ultrasound plus aspirin plus MRX-815 microbubbles). Group 3 was infused with IV bubbles over 1 hour at 0.16cc/kg. Ultrasound was delivered to the dehaired side of the head during bubble infusion and for 1 additional hour at 0.8 W/cm2 20% pulsed wave. Rabbits survived for 22 to 24 hours, were imaged with computerized tomography and 3 Tesla magnetic resonance imaging including contrast studies, and sacrificed. Tetrazolium (TTC) and Hematoxylin and Eosin (H&E) sections were made for pathological examination. Results: All 24 animals showed absence of bleeding, endothelial damage, EKG abnormalities, stroke, blood-brain-barrier breakdown, or other acute abnormalities. CT and MRI showed no bleeding or signs of stroke, but two animals had mild hydrocephalus. The EKGs showed normal variation in QTc. Rabbit behavior was normal in all. Minimal chronic inflammation unrelated to the study was seen in 5. Two animals were excluded because of protocol violations and replaced during the study. Conclusion: The administered dose of microbubbles and ultrasound demonstrated no detrimental effects on the healthy rabbit animal model.

  20. Point-of-care cardiac ultrasound techniques in the physical examination: better at the bedside.

    PubMed

    Kimura, Bruce J

    2017-07-01

    The development of hand-carried, battery-powered ultrasound devices has created a new practice in ultrasound diagnostic imaging, called 'point-of-care' ultrasound (POCUS). Capitalising on device portability, POCUS is marked by brief and limited ultrasound imaging performed by the physician at the bedside to increase diagnostic accuracy and expediency. The natural evolution of POCUS techniques in general medicine, particularly with pocket-sized devices, may be in the development of a basic ultrasound examination similar to the use of the binaural stethoscope. This paper will specifically review how POCUS improves the limited sensitivity of the current practice of traditional cardiac physical examination by both cardiologists and non-cardiologists. Signs of left ventricular systolic dysfunction, left atrial enlargement, lung congestion and elevated central venous pressures are often missed by physical techniques but can be easily detected by POCUS and have prognostic and treatment implications. Creating a general set of repetitive imaging skills for these entities for application on all patients during routine examination will standardise and reduce heterogeneity in cardiac bedside ultrasound applications, simplify teaching curricula, enhance learning and recollection, and unify competency thresholds and practice. The addition of POCUS to standard physical examination techniques in cardiovascular medicine will result in an ultrasound-augmented cardiac physical examination that reaffirms the value of bedside diagnosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Ultra-high frequency ultrasound biomicroscopy and high throughput cardiovascular phenotyping in a large scale mouse mutagenesis screen

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoqin; Francis, Richard; Tobita, Kimimasa; Kim, Andy; Leatherbury, Linda; Lo, Cecilia W.

    2013-02-01

    Ultrasound biomicroscopy (UBM) is ideally suited for phenotyping fetal mice for congenital heart disease (CHD), as imaging can be carried out noninvasively to provide both hemodynamic and structural information essential for CHD diagnosis. Using the UBM (Vevo 2100; 40Hz) in conjunction with the clinical ultrasound system (Acuson Sequioa C512; 15Hz), we developed a two-step screening protocol to scan thousands fetuses derived from ENU mutagenized pedigrees. A wide spectrum of CHD was detected by the UBM, which were subsequently confirmed with follow-up necropsy and histopathology examination with episcopic fluorescence image capture. CHD observed included outflow anomalies, left/right heart obstructive lesions, septal/valvular defects and cardiac situs anomalies. Meanwhile, various extracardiac defects were found, such as polydactyly, craniofacial defects, exencephaly, omphalocele-cleft palate, most of which were associated with cardiac defects. Our analyses showed the UBM was better at assessing cardiac structure and blood flow profiles, while conventional ultrasound allowed higher throughput low-resolution screening. Our study showed the integration of conventional clinical ultrasound imaging with the UBM for fetal mouse cardiovascular phenotyping can maximize the detection and recovery of CHD mutants.

  2. Impact of vaginal-rectal ultrasound examinations with covered and low-level disinfected transducers on infectious transmissions in france.

    PubMed

    Leroy, Sandrine; M'Zali, Fatima; Kann, Michael; Weber, David J; Smith, David D

    2014-12-01

    The risk of cross-infection from shared ultrasound probes in endorectal and vaginal ultrasonography due to low-level disinfection (LLD) is difficult to estimate because potential infections are also sexually transmitted diseases, and route of contamination is often difficult to establish. In France, the widely used standard for prevention of infections is through the use of probe covers and LLD of the ultrasound transducer by disinfectant wipes. We performed an in silico simulation based on a systematic review to estimate the number of patients infected after endorectal or vaginal ultrasonography examination using LLD for probes. We performed a stochastic Monte Carlo computer simulation to produce hypothetical cohorts for a population of 4 million annual ultrasound examinations performed in France, and we estimated the number of infected patients for human immunodeficiency virus (HIV), herpes simplex virus, hepatitis B virus, hepatitis C virus, human papilloma virus, cytomegalovirus, and Chlamydia trachomatis. Modeling parameters were estimated by meta-analysis when possible. The probability of infection from a contaminated probe ranged from 1% to 6%, depending on the pathogen. For cases of HIV infection, this would result in approximately 60 infected patients per year. For other common viral infections, the number of new cases ranged from 1,600 to 15,000 per year that could be attributable directly to ultrasound and LLD procedures. Our simulation results showed that, despite cumulative use of probe cover and LLD, there were still some cases of de novo infection that may be attributable to ultrasound procedures. These cases are preventable by reviewing the currently used LLD and/or upgrading LLD to high-level disinfection, as recommended by the US Centers for Disease Control and Prevention.

  3. Painless thyroiditis associated to thyroid carcinoma: role of initial ultrasonography evaluation.

    PubMed

    Valentini, Raisa Bressan; Macedo, Bruno Mussoi de; Izquierdo, Rogério Friedrich; Meyer, Erika Laurini Souza

    2016-04-01

    Even though it is a rare event, most associations of thyroid carcinoma with subacute thyroiditis described in the literature are related to its granulomatous form (Quervain's thyroiditis). We present a patient with subacute lymphocytic thyroiditis (painless thyroiditis) and papillary thyroid cancer that was first suspected in an initial ultrasound evaluation. A 30-year old female patient who was referred to the emergency room due to hyperthyroidism symptoms was diagnosed with painless thyroiditis established by physical examination and laboratory findings. With the presence of a palpable painless thyroid nodule an ultrasound was prescribed and the images revealed a suspicious thyroid nodule, microcalcification focus in the heterogeneous thyroid parenquima and cervical lymphadenopathy. Fine needle aspiration biopsy was taken from this nodule; cytology was assessed for compatibility with papillary thyroid carcinoma. Postsurgical pathology evaluation showed a multicentric papillary carcinoma and lymphocytic infiltration. Subacute thyroiditis, regardless of type, may produce transitory ultrasound changes that obscure the coexistence of papillary carcinoma. Due to this, initial thyroid ultrasound evaluation should be delayed until clinical recovery. We recommended a thyroid ultrasound exam for initial evaluation of painless thyroiditis, particularly in patients with palpable thyroid nodule. Further cytological examination is recommended in cases presenting with suspect thyroid nodule and/or non-nodular hypoechoic (> 1 cm) or heterogeneous areas with microcalcification focus.

  4. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    PubMed

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  5. The value and economic analysis of routine postoperative carotid duplex ultrasound surveillance after carotid endarterectomy.

    PubMed

    AbuRahma, Ali F; Srivastava, Mohit; AbuRahma, Zachary; Jackson, Will; Mousa, Albeir; Stone, Patrick A; Dean, L Scott; Green, Jason

    2015-08-01

    Several studies have reported on the role of postoperative duplex ultrasound surveillance after carotid endarterectomy (CEA) with varying results. Most of these studies had a small sample size or did not analyze cost-effectiveness. We analyzed 489 of 501 CEA patients with patch closure. All patients had immediate postoperative duplex ultrasound examination and were routinely followed up both clinically and with duplex ultrasound at regular intervals of 1 month, 6 months, 12 months, and every 12 months thereafter. A Kaplan-Meier analysis was used to estimate the rate of ≥50% and ≥80% post-CEA restenosis over time and the time frame of progression from normal to ≥50% or ≥80% restenosis. The cost of post-CEA duplex surveillance was also estimated. Overall, 489 patients with a mean age of 68.5 years were analyzed. Ten of these had residual postoperative ≥50% stenosis, and 37 did not undergo a second duplex ultrasound examination and therefore were not included in the final analysis. The mean follow-up was 20.4 months (range, 1-63 months), with a mean number of duplex ultrasound examinations of 3.6 (range, 1-7). Eleven of 397 patients (2.8%) with a normal finding on immediate postoperative duplex ultrasound vs 4 of 45 (8.9%) with mild stenosis on immediate postoperative duplex ultrasound progressed to ≥50% restenosis (P = .055). Overall, 15 patients (3.1%) had ≥50% restenosis, 9 with 50% to <80% and 4 with 80% to 99% (2 of these had carotid artery stenting reintervention), and 2 had late carotid occlusion. All of these were asymptomatic, except for one who had a transient ischemic attack. The mean time to ≥50% to <80% restenosis was 14.7 months vs 19.8 months for ≥80% restenosis after the CEA. Freedom from restenosis rates were 98%, 96%, 94%, 94%, and 94% for ≥50% restenosis and 99%, 98%, 97%, 97%, and 97% for ≥80% restenosis at 1 year, 2 years, 3 years, 4 years, and 5 years, respectively. Freedom from myocardial infarction, stroke, and deaths was not significantly different between patients with and without restenosis (100%, 93%, 83%, and 83% vs 94%, 91%, 86%, and 79% at 1 year, 2 years, 3 years, and 4 years, respectively; P = .951). The estimated charge of this surveillance was 3.6 × 489 (number of CEAs) × $800 (charge for carotid duplex ultrasound), which equals $1,408,320, to detect only four patients with ≥80% to 99% restenosis who may have been potential candidates for reintervention. This study shows that the value of routine postoperative duplex ultrasound surveillance after CEA with patch closure may be limited, particularly if the finding on immediate postoperative duplex ultrasound is normal or shows minimal disease. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  6. Point-of-care ultrasound education for non-physician clinicians in a resource-limited emergency department.

    PubMed

    Stolz, Lori A; Muruganandan, Krithika M; Bisanzo, Mark C; Sebikali, Mugisha J; Dreifuss, Bradley A; Hammerstedt, Heather S; Nelson, Sara W; Nayabale, Irene; Adhikari, Srikar; Shah, Sachita P

    2015-08-01

    To describe the outcomes and curriculum components of an educational programme to train non-physician clinicians working in a rural, Ugandan emergency department in the use of POC ultrasound. The use of point-of-care ultrasound was taught to emergency care providers through lectures, bedsides teaching and hands-on practical sessions. Lectures were tailored to care providers' knowledge base and available therapeutic means. Every ultrasound examination performed by these providers was recorded over 4.5 years. Findings of these examinations were categorised as positive, negative, indeterminate or procedural. Other radiologic studies ordered over this same time period were also recorded. A total of 22,639 patients were evaluated in the emergency department by emergency care providers, and 2185 point-of-care ultrasound examinations were performed on 1886 patients. Most commonly used were the focused assessment with sonography in trauma examination (53.3%) and echocardiography (16.4%). Point-of-care ultrasound studies were performed more frequently than radiology department-performed studies. Positive findings were documented in 46% of all examinations. We describe a novel curriculum for point-of-care ultrasound education of non-physician emergency practitioners in a resource-limited setting. These non-physician clinicians integrated ultrasound into clinical practice and utilised this imaging modality more frequently than traditional radiology department imaging with a large proportion of positive findings. © 2015 John Wiley & Sons Ltd.

  7. Tempo and mode of antibat ultrasound production and sonar jamming in the diverse hawkmoth radiation.

    PubMed

    Kawahara, Akito Y; Barber, Jesse R

    2015-05-19

    The bat-moth arms race has existed for over 60 million y, with moths evolving ultrasonically sensitive ears and ultrasound-producing organs to combat bat predation. The evolution of these defenses has never been thoroughly examined because of limitations in simultaneously conducting behavioral and phylogenetic analyses across an entire group. Hawkmoths include >1,500 species worldwide, some of which produce ultrasound using genital stridulatory structures. However, the function and evolution of this behavior remain largely unknown. We built a comprehensive behavioral dataset of hawkmoth hearing and ultrasonic reply to sonar attack using high-throughput field assays. Nearly half of the species tested (57 of 124 species) produced ultrasound to tactile stimulation or playback of bat echolocation attack. To test the function of ultrasound, we pitted big brown bats (Eptesicus fuscus) against hawkmoths over multiple nights and show that hawkmoths jam bat sonar. Ultrasound production was immediately and consistently effective at thwarting attack and bats regularly performed catching behavior without capturing moths. We also constructed a fossil-calibrated, multigene phylogeny to study the evolutionary history and divergence times of these antibat strategies across the entire family. We show that ultrasound production arose in multiple groups, starting in the late Oligocene (∼ 26 Ma) after the emergence of insectivorous bats. Sonar jamming and bat-detecting ears arose twice, independently, in the Miocene (18-14 Ma) either from earless hawkmoths that produced ultrasound in response to physical contact only, or from species that did not respond to touch or bat echolocation attack.

  8. Ultrasound examination and behavior scoring of captive broadnose sevengill sharks, Notorynchus cepedianus (Peron, 1807).

    PubMed

    Daly, Jonathan; Gunn, Ian; Kirby, Nick; Jones, Robert; Galloway, David

    2007-09-01

    Serial ultrasound examination of four mature female sevengill sharks (Notorynchus cepedianus) was carried out over 18 months. Monitoring the reproductive cycle and development of follicles and fetuses in sharks in a noninvasive manner using this technique has not been reported previously. Sharks were caught out of the "Oceanarium" tank by divers using a specially made catch-out bag, and brought to a holding area for examination. A behavior scoring system was used to monitor the impact of regular handling on the well-being of the animals. Ultrasound showed the growth and regression of follicles in sevengill ovaries, and allowed an approximation of the reproductive stage of these sharks. Monitoring behavior at five time points during the procedure showed that regular handling of sharks for clinical studies could be done with minimal impact on animal welfare. The ability to follow reproductive events in elasmobranches using ultrasonography is an important step in the application of assisted reproductive technology in these species. Assisted reproductive technology, such as monitoring female reproductive cycles and artificial insemination, could potentially be used to maintain genetic diversity and compliment aquaria-based breeding programs for endangered species such as the gray nurse shark (Carcharias taurus). Zoo Biol 26:383-395, 2007. (c) 2007 Wiley-Liss, Inc.

  9. Villous adenoma of the common hepatic duct: the importance of contrast-enhanced ultrasound and endoscopic retrograde cholangiopancreatography for relevant diagnosis. A case report and review of the literature.

    PubMed

    Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu

    2015-12-01

    Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.

  10. Objective diagnosis of arrested labor on transperineal ultrasound.

    PubMed

    Nishimura, Kazuaki; Yoshimura, Kazuaki; Kubo, Tatsuhiko; Hachisuga, Toru

    2016-07-01

    Recent developments in transperineal ultrasound imaging of the pelvis have prompted trials to objectively evaluate labor progression for labor management. We evaluated the accuracy of transperineal ultrasound in diagnosing arrest of labor. Transperineal ultrasound and digital pelvic examinations were performed simultaneously in 63 term laboring patients (singleton fetuses in cephalic presentation). We analyzed a total of 216 ultrasound images (Sonography Volume Computer Aided Display Labor [Sono VCAD Labor®] installed in Voluson E8 ultrasound). We examined the correlation between the three ultrasound parameters head direction (HD), progression distance (PD), and progression angle (PA), and digital pelvic examination findings during labor in a transvaginal delivery group and an arrested labor group. The coefficient of correlations between HD/PD/PA and cervical dilation/fetal station were 0.667/0.657/0.706 and 0.667/0.751/0.803, respectively. The three parameters had strong correlations with digital pelvic examination (P < 0.05). In the 11 cases (17%) of cesarean section due to arrested labor, the position of the fetal head was visually unchanged on sequential ultrasound images. According to receiver operating characteristic curves, the significant cut-offs for HD, PD, and PA for arrested labor were 105° (P = 0.048), 35 mm (P = 0.048), and 120° (P = 0.001), respectively. Transperineal ultrasound imaging is helpful for objective evaluation of labor progression and the diagnosis of arrested labor. © 2016 Japan Society of Obstetrics and Gynecology.

  11. Summative Objective Structured Clinical Examination Assessment at the End of Anesthesia Residency for Perioperative Ultrasound.

    PubMed

    Mitchell, John D; Amir, Rabia; Montealegre-Gallegos, Mario; Mahmood, Feroze; Shnider, Marc; Mashari, Azad; Yeh, Lu; Bose, Ruma; Wong, Vanessa; Hess, Philip; Amador, Yannis; Jeganathan, Jelliffe; Jones, Stephanie B; Matyal, Robina

    2018-06-01

    While standardized examinations and data from simulators and phantom models can assess knowledge and manual skills for ultrasound, an Objective Structured Clinical Examination (OSCE) could assess workflow understanding. We recruited 8 experts to develop an OSCE to assess workflow understanding in perioperative ultrasound. The experts used a binary grading system to score 19 graduating anesthesia residents at 6 stations. Overall average performance was 86.2%, and 3 stations had an acceptable internal reliability (Kuder-Richardson formula 20 coefficient >0.5). After refinement, this OSCE can be combined with standardized examinations and data from simulators and phantom models to assess proficiency in ultrasound.

  12. Rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating heart failure from pulmonary disease as the cause of acute dyspnea in the emergency setting

    PubMed Central

    2012-01-01

    Background Rapid and accurate diagnosis and management can be lifesaving for patients with acute dyspnea. However, making a differential diagnosis and selecting early treatment for patients with acute dyspnea in the emergency setting is a clinical challenge that requires complex decision-making in order to achieve hemodynamic balance, improve functional capacity, and decrease mortality. In the present study, we examined the screening potential of rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating acute heart failure syndromes (AHFS) from primary pulmonary disease in patients with acute dyspnea in the emergency setting. Methods Between March 2011 and March 2012, 90 consecutive patients (45 women, 78.1 ± 9.9 years) admitted to the emergency room of our hospital for acute dyspnea were enrolled. Within 30 minutes of admission, all patients underwent conventional physical examination, rapid ultrasound (lung-cardiac-inferior vena cava [LCI] integrated ultrasound) examination with a hand-held device, routine laboratory tests, measurement of brain natriuretic peptide, and chest X-ray in the emergency room. Results The final diagnosis was acute dyspnea due to AHFS in 53 patients, acute dyspnea due to pulmonary disease despite a history of heart failure in 18 patients, and acute dyspnea due to pulmonary disease in 19 patients. Lung ultrasound alone showed a sensitivity, specificity, negative predictive value, and positive predictive value of 96.2, 54.0, 90.9, and 75.0%, respectively, for differentiating AHFS from pulmonary disease. On the other hand, LCI integrated ultrasound had a sensitivity, specificity, negative predictive value, and positive predictive value of 94.3, 91.9, 91.9, and 94.3%, respectively. Conclusions Our study demonstrated that rapid evaluation by LCI integrated ultrasound is extremely accurate for differentiating acute dyspnea due to AHFS from that caused by primary pulmonary disease in the emergency setting. PMID:23210515

  13. Renal denervation by intravascular ultrasound: Preliminary in vivo study

    NASA Astrophysics Data System (ADS)

    Sinelnikov, Yegor; McClain, Steve; Zou, Yong; Smith, David; Warnking, Reinhard

    2012-10-01

    Ultrasound denervation has recently become a subject of intense research in connection with the treatment of complex medical conditions including neurological conditions, development of pain management, reproduction of skin sensation, neuropathic pain and spasticity. The objective of this study is to investigate the use of intravascular ultrasound to produce nerve damage in renal sympathetic nerves without significant injury to the renal artery. This technique may potentially be used to treat various medical conditions, such as hypertension. The study was approved by the Institutional Animal Care and Use Committee. Ultrasound was applied to renal nerves of the swine model for histopathological evaluation. Therapeutic ultrasound energy was delivered circumferentially by an intravascular catheter maneuvered into the renal arteries. Fluoroscopic imaging was conducted pre-and post-ultrasound treatment. Animals were recovered and euthanized up to 30 hours post procedure, followed by necropsy and tissue sample collection. Histopathological examination showed evidence of extensive damage to renal nerves, characterized by nuclear pyknosis, hyalinization of stroma and multifocal hemorrhages, with little or no damage to renal arteries. This study demonstrates the feasibility of intravascular ultrasound as a minimally invasive renal denervation technique. Further studies are necessary to evaluate the long-term safety and efficacy of this technique and its related clinical significance.

  14. [The development of obstetric ultrasound in Switzerland].

    PubMed

    Zimmermann, Roland

    2005-04-01

    Ultrasound has conquered obstetrics during the last 40 years. Today it is an integral part of antenatal care. Its broad use as a screening method has pushed critics who found open doors at health authorities facing short resources. In Switzerland in early 1996, routine ultrasound as a health technology was temporarily excluded from reimbursement by the health insurances. Under the pressure of the public, the health authorities had to reintroduce reimbursement within a few months. However, reimbursement was linked with several conditions: the ultrasound examination has to be performed by physicians with adequate training and experience; routine ultrasound needs a strict informed consent, and its benefit has to be evidenced. This decision has had a positive impact on quality. After 7 years, Switzerland has a good training program; guidelines for prenatal ultrasound already exist in their second edition, and spot checks of performance showed that quality in Switzerland meets international standards. Ultrasound mainly has a positive cost-effectiveness ratio due to the detection of fetal malformations with consecutive termination of pregnancy. Since termination of pregnancy is ethically questionable, the discussion with respect to reimbursement will most probably go on. In this light, a comprehensive informed consent of the pregnant women is essential.

  15. No effect of prolonged pulsed high frequency ultrasound imaging of the basilar membrane on cochlear function or hair cell survival found in an initial study.

    PubMed

    Landry, Thomas G; Bance, Manohar L; Adamson, Robert B; Brown, Jeremy A

    2018-06-01

    Miniature high frequency ultrasound devices show promise as tools for clinical middle ear and basal cochlea imaging and vibrometry. However, before clinical use it is important to verify that the ultrasound exposure does not damage the cochlea. In this initial study, electrophysiological responses of the cochlea were measured for a range of stimulus frequencies in both ears of anesthetized chinchillas, before and after exposing the organ of Corti region of one ear to pulsed focused ultrasound for 30 min. Measurements were again taken after an 11 day survival period. Cochlear tissue was examined with a confocal microscope for signs of damage to the cochlear hair cells. No significant change in response thresholds due to exposure was found, and no signs of ultrasound-induced tissue damage were observed, although one animal (out of ten) did have a region of extensive tissue damage in the exposed cochlea. However, after further analysis this was concluded to be not likely a result of the ultrasound exposure. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Standardized Six-Step Approach to the Performance of the Focused Basic Obstetric Ultrasound Examination.

    PubMed

    Abuhamad, Alfred; Zhao, Yili; Abuhamad, Sharon; Sinkovskaya, Elena; Rao, Rashmi; Kanaan, Camille; Platt, Lawrence

    2016-01-01

    This study aims to validate the feasibility and accuracy of a new standardized six-step approach to the performance of the focused basic obstetric ultrasound examination, and compare the new approach to the regular approach performed in the scheduled obstetric ultrasound examination. A new standardized six-step approach to the performance of the focused basic obstetric ultrasound examination, to evaluate fetal presentation, fetal cardiac activity, presence of multiple pregnancy, placental localization, amniotic fluid volume evaluation, and biometric measurements, was prospectively performed on 100 pregnant women between 18(+0) and 27(+6) weeks of gestation and another 100 pregnant women between 28(+0) and 36(+6) weeks of gestation. The agreement of findings for each of the six steps of the standardized six-step approach was evaluated against the regular approach. In all ultrasound examinations performed, substantial to perfect agreement (Kappa value between 0.64 and 1.00) was observed between the new standardized six-step approach and the regular approach. The new standardized six-step approach to the focused basic obstetric ultrasound examination can be performed successfully and accurately between 18(+0) and 36(+6) weeks of gestation. This standardized approach can be of significant benefit to limited resource settings and in point of care obstetric ultrasound applications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Comparison of the learning curves of digital examination and transabdominal sonography for the determination of fetal head position during labor.

    PubMed

    Rozenberg, P; Porcher, R; Salomon, L J; Boirot, F; Morin, C; Ville, Y

    2008-03-01

    To evaluate the learning curve of transabdominal sonography for the determination of fetal head position in labor and to compare it with that of digital vaginal examination. A student midwife who had never performed digital vaginal examination or ultrasound examination was recruited for this study. Instructions on how to perform digital vaginal examination and ultrasound examination were given before and after completing the first vaginal and ultrasound examinations, and repeated for each subsequent examination for as long as necessary. Digital and ultrasound diagnoses of the fetal head position were always performed first by the student midwife, and repeated by an experienced midwife or physician. The learning curve for identification of the fetal head position by either one of the two methods was analyzed using the cumulative sums (CUSUM) method for measurement errors. One hundred patients underwent digital vaginal examination and 99 had transabdominal sonography for the determination of fetal head position. An error rate of around 50% for vaginal examination was nearly constant during the first 50 examinations. It decreased subsequently, to stabilize at a low level from the 82(nd) patient. Errors of +/- 180 degrees were the most frequent. The learning curve for ultrasound imaging stabilized earlier than that of vaginal examination, after the 32(nd) patient. The most frequent errors with ultrasound examination were the inability to conclude on a diagnosis, particularly at the beginning of training, followed by errors of +/- 45 degrees. Based on our findings for the student tested, learning and accuracy of the determination of fetal head position in labor were easier and higher, respectively, with transabdominal sonography than with digital examination. This should encourage physicians to introduce clinical ultrasound examination into their practice. CUSUM charts provide a reliable representation of the learning curve, by accumulating evidence of performance. Copyright (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.

  18. Model based inversion of ultrasound data in composites

    NASA Astrophysics Data System (ADS)

    Roberts, R. A.

    2018-04-01

    Work is reported on model-based defect characterization in CFRP composites. The work utilizes computational models of ultrasound interaction with defects in composites, to determine 1) the measured signal dependence on material and defect properties (forward problem), and 2) an assessment of defect properties from analysis of measured ultrasound signals (inverse problem). Work is reported on model implementation for inspection of CFRP laminates containing multi-ply impact-induced delamination, in laminates displaying irregular surface geometry (roughness), as well as internal elastic heterogeneity (varying fiber density, porosity). Inversion of ultrasound data is demonstrated showing the quantitative extraction of delamination geometry and surface transmissivity. Additionally, data inversion is demonstrated for determination of surface roughness and internal heterogeneity, and the influence of these features on delamination characterization is examined. Estimation of porosity volume fraction is demonstrated when internal heterogeneity is attributed to porosity.

  19. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    PubMed

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (p<0.001). There was no difference between the AUC of conventional ultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  20. Improved extraction of avocado oil by application of sono-physical processes.

    PubMed

    Martínez-Padilla, Laura Patricia; Franke, Lisa; Xu, Xin-Qing; Juliano, Pablo

    2018-01-01

    Ultrasound treatment is known to increase the oil extractability in olive and palm oil processes. This work examined the effect of ultrasound conditioning of avocado puree on oil extractability and quality, at low (18+40kHz) and high (2MHz) frequencies, at litre-scale. Other ultrasound parameters evaluated included high frequency effect (0.4, 0.6, and 2MHz; 5min; 90kJ/kg) and sonication time (2.5-10min at 2MHz), without malaxation. Finally, a megasonic post-malaxation intervention was assessed at selected malaxation times (15, 30, and 60min). Both low and high frequency ultrasound treatments of the non-malaxed avocado puree improved extractability by 15-24% additional oil recovery, with the highest extractability achieved after 2MHz treatments, depending on the fruit maturity and oil content. There was no preferential improvement on oil extractability observed across high frequencies, even though extractability increased with sonication time. Ultrasound treatment also showed a positive effect after puree malaxation. Oils obtained from sonicated purees showed peroxide and free fatty acid values below the industrial specification levels and an increase in total phenolic compounds after 2MHz treatment. High frequency ultrasound conditioning of avocado puree can enhance oil separation and potentially decrease the malaxation time in industrial processes without impacting on oil quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. [Ultrasound monitoring of consolidation processes in fractures of long tubular bones in osteosynthesis using bioactive implants].

    PubMed

    Zavadovskaia, V D; Popov, V P; Akbasheva, O E; Grigor'ev, E G; Druzhinina, T V

    2014-01-01

    To show the capabilities of ultrasound monitoring to assess consolidation processes in fractures of long tubular bones in the use of bioactive material-containing implants. Eighty-two (45.1%) patients whose bone fragments had been fixed with bioactive material-coated plates and 100 (54.9%) patients with bioinert material-coated ones were examined. Consolidation changes were estimated by ultrasound and X-ray studies 2, 4, 6, and 12 months after surgery. Bone metabolic changes were determined by US osteometry 2 months following surgery. Ultrasound data were compared with the biochemical markers: C-terminal telopeptide (CrossLaps) and osteocalcin. Ultrasound monitoring of the rates of consolidation and the time course of changes in bone strength versus the biochemical markers established the positive effect of bioactiveplates on the process of consolidation in fractures of tubular bones and made it possible to consider local osteopenic syndrome to be a prognostically favorable sign of timely callus formation.

  2. An Experimental Model Using Cultured Cardiac Myocytes for a Study of the Generation of Premature Ventricular Contractions Under Ultrasound Exposure

    NASA Astrophysics Data System (ADS)

    Kudo, Nobuki; Yamamoto, Masaya

    2011-09-01

    It is known that use of a contrast agents in echocardiography increases the probability of generation of premature ventricular contractions (PVCs). As a basic study to elucidate the mechanisms and to reduce adverse effects, the generation of PVCs was investigated using cultured cardiac myocytes instead of the intact heart in vivo. Cardiac myocytes were isolated from neonatal rats and cultured on a cover slip. The myocyte sample was exposed to pulsed ultrasound with microbubbles adjacent to the myocytes, and generation of PVCs was examined with ultrasound exposure at various delay times after onset of myocyte contraction. The experimental results showed that generation of PVCs had a stable threshold delay time and that PVCs were generated only when myocytes were exposed to ultrasound with delay times longer than the threshold. The results indicate that the model used in this study is useful for revealing the mechanisms by which PVCs are induced by ultrasound exposure.

  3. Reproducibility of Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Thermal Lesions in Minimally-Invasive Brain Surgery

    NASA Astrophysics Data System (ADS)

    Zahedi, Sulmaz

    This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.

  4. An orthopedist's guide to shoulder ultrasound: a systematic review of examination protocols.

    PubMed

    Amoo-Achampong, Kelms; Nwachukwu, Benedict U; McCormick, Frank

    2016-11-01

    The utilization of musculoskeletal ultrasound has expanded within the setting of the orthopedic clinic as a cost-effective, point-of-care diagnostic tool for shoulder pathology. In experienced hands, ultrasound exhibits capabilities equivalent to that of magnetic resonance imaging in the diagnosis of many shoulder diseases including full-thickness and partial-thickness rotator cuff tears. Although similarly effective in identifying additional shoulder disease processes, major obstacles to its widespread use include user dependence and intrinsic limitation to extra-articular diagnosis. The purpose of this review is to present a step-by-step guide of how to perform a comprehensive shoulder examination and to discuss the appropriate use, economic benefit and implementation of ultrasound within the clinic. A systematic search (June 2016) of PubMed, Scopus, and EMBASE databases was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for literature presenting shoulder ultrasound examination protocols. Included studies were peer-reviewed articles or academic society endorsed protocols presenting comprehensive sonographic examinations of the adult shoulder. Papers with limited or single structure examination descriptions, non-English language, and publication dates before 1980 were excluded. Final papers meeting criteria were secondarily screened for publication after 2005 to reflect the current state of ultrasound imaging. The search yielded 1,725 unique articles with 17 studies meeting final selection criteria. Information from identified studies was summarized to formulate a 4-part shoulder examination protocol, including steps most pertinent to orthopedic in-office diagnoses. In agreement with previous studies, the inexperienced orthopedic surgeon can be quickly trained to expert level proficiency in shoulder ultrasound diagnosis. Using an established protocol, a comprehensive, yet effective shoulder ultrasound examination can be performed within ten minutes. Further, ultrasound provides opportunity to off-set costs through the engagement of revenue generating activity for the orthopedic practice.

  5. Immediate postpartum ultrasound evaluation for suspected retained placental tissue in patients undergoing manual removal of placenta.

    PubMed

    Weissbach, T; Haikin-Herzberger, E; Bacci-Hugger, K; Shechter-Maor, G; Fejgin, M; Biron-Shental, T

    2015-09-01

    Approximately 1% of term deliveries are complicated by retained products of conception. Untreated, this condition may cause bleeding, infection and intrauterine adhesions. This study assessed whether performing routine bedside uterine ultrasound immediately after manual removal of the placenta reduced the occurrence of undiagnosed, retained products of conception and its associated complications. A retrospective study was conducted using the records of patients who delivered and underwent manual removal of placenta at a single obstetrics center over a 6-year period. The outcomes of patients who were assessed using immediate bedside ultrasound were compared to a similar group who were treated based on clinical evaluation alone. All patients underwent ultrasound examination prior to discharge. Outcome variables included the rate of additional interventions (medical or surgical), abnormal pre-discharge uterine ultrasound findings, postpartum hemorrhage rate, puerperal fever and length of hospital stay. A total of 399 charts were reviewed. Immediate post-procedural ultrasound was performed in 235 patients. The remaining 164 women did not undergo immediate post-procedural ultrasound. All patients underwent an ultrasound examination prior to discharge. Among the patients who had an immediate post-procedural ultrasound, 12 (5.1%) received immediate re-intervention (2 methergine, 6 curettage and 4 manual uterine revision) vs. no intervention in the second group (p<0.001). No statistically significant difference was found between the group of patients who had immediate post-procedural ultrasound and those who did not, in the rates of postpartum hemorrhage (3.1% vs. 0.7%, p=0.13), abnormal ultrasound findings prior to discharge (14.9% vs. 14.8%, p=0.96) or additional late intervention (7.2% vs. 7.9%, p=0.79), respectively. Our findings suggest that immediate, bedside uterine ultrasound examination after manual removal of placenta might not change patient outcomes. Furthermore, it might increase unnecessary interventions. Further studies are needed to prospectively assess the benefit of routine uterine ultrasound examination after manual removal of placenta. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Ultrasonography of uterine leiomyomas.

    PubMed

    Woźniak, Andrzej; Woźniak, Sławomir

    2017-12-01

    Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan - TVS) or transabdominally (transabdominal scan - TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus.

  7. Errors in the ultrasound diagnosis of the kidneys, ureters and urinary bladder

    PubMed Central

    Wieczorek, Andrzej Paweł; Tyloch, Janusz F.

    2013-01-01

    The article presents the most frequent errors made in the ultrasound diagnosis of the urinary system. They usually result from improper technique of ultrasound examination or its erroneous interpretation. Such errors are frequent effects of insufficient experience of the ultrasonographer, inadequate class of the scanner, insufficient knowledge of its operation as well as of wrong preparation of patients, their constitution, severe condition and the lack of cooperation during the examination. The reasons for misinterpretations of ultrasound images of the urinary system may lie in a large polymorphism of the kidney (defects and developmental variants) and may result from improper access to the organ as well as from the presence of artefacts. Errors may also result from the lack of knowledge concerning clinical and laboratory data. Moreover, mistakes in ultrasound diagnosis of the urinary system are frequently related to the lack of knowledge of the management algorithms and diagnostic possibilities of other imaging modalities. The paper lists errors in ultrasound diagnosis of the urinary system divided into: errors resulting from improper technique of examination, artefacts caused by incorrect preparation of patients for the examination or their constitution and errors resulting from misinterpretation of ultrasound images of the kidneys (such as their number, size, fluid spaces, pathological lesions and others), ureters and urinary bladder. Each physician performing kidney or bladder ultrasound examination should possess the knowledge of the most frequent errors and their causes which might help to avoid them. PMID:26674139

  8. Biological effects of low frequency high intensity ultrasound application on ex vivo human adipose tissue.

    PubMed

    Palumbo, P; Cinque, B; Miconi, G; La Torre, C; Zoccali, G; Vrentzos, N; Vitale, A R; Leocata, P; Lombardi, D; Lorenzo, C; D'Angelo, B; Macchiarelli, G; Cimini, A; Cifone, M G; Giuliani, M

    2011-01-01

    In the present work the effects of a new low frequency, high intensity ultrasound technology on human adipose tissue ex vivo were studied. In particular, we investigated the effects of both external and surgical ultrasound-irradiation (10 min) by evaluating, other than sample weight loss and fat release, also histological architecture alteration as well apoptosis induction. The influence of saline buffer tissue-infiltration on the effects of ultrasound irradiation was also examined. The results suggest that, in our experimental conditions, both transcutaneous and surgical ultrasound exposure caused a significant weight loss and fat release. This effect was more relevant when the ultrasound intensity was set at 100 % (~2.5 W/cm², for external device; ~19-21 W/cm2, for surgical device) compared to 70 % (~1.8 W/cm² for external device; ~13-14 W/cm2 for surgical device). Of note, the effectiveness of ultrasound was much higher when the tissue samples were previously infiltrated with saline buffer, in accordance with the knowledge that ultrasonic waves in aqueous solution better propagate with a consequently more efficient cavitation process. Moreover, the overall effects of ultrasound irradiation did not appear immediately after treatment but persisted over time, being significantly more relevant at 18 h from the end of ultrasound irradiation. Evaluation of histological characteristics of ultrasound-irradiated samples showed a clear alteration of adipose tissue architecture as well a prominent destruction of collagen fibers which were dependent on ultrasound intensity and most relevant in saline buffer-infiltrated samples. The structural changes of collagen bundles present between the lobules of fat cells were confirmed through scanning electron microscopy (SEM) which clearly demonstrated how ultrasound exposure induced a drastic reduction in the compactness of the adipose connective tissue and an irregular arrangement of the fibers with a consequent alteration in the spatial architecture. The analysis of the composition of lipids in the fat released from adipose tissue after ultrasound treatment with surgical device showed, in agreement with the level of adipocyte damage, a significant increase mainly of triglycerides and cholesterol. Finally, ultrasound exposure had been shown to induce apoptosis as shown by the appearance DNA fragmentation. Accordingly, ultrasound treatment led to down-modulation of procaspase-9 expression and an increased level of caspase-3 active form.

  9. Thickening of the inferior glenohumeral capsule: an ultrasound sign for shoulder capsular contracture.

    PubMed

    Michelin, Paul; Delarue, Yohann; Duparc, Fabrice; Dacher, Jean Nicolas

    2013-10-01

    The aim of this retrospective study was to measure the inferior glenohumeral capsule thickness of shoulders clinically affected by capsular contracture by comparison to the contralateral asymptomatic side. Bilateral shoulder ultrasound (US) examinations of 20 patients with clinically or MRI proven unilateral capsular contracture were retrospectively assessed. Inferior capsule evaluation was performed with a transducer placed within the axilla in maximally abducted shoulders. Measurements were symmetrically performed orthogonally to the inferior glenohumeral ligament (IGHL) in the axial plane; the coronal plane was used to ensure the tension of the IGHL. The significance of any difference in thickening was assessed with the Mann-Whitney test. The average thickness was 4.0 mm in shoulders with capsular contracture vs. 1.3 mm in asymptomatic contralateral shoulders (P < 0.0001). Twenty per cent of patients with capsular contracture and inferior capsule thickness increase showed US features of other painful diseases of the rotator cuff. The thickness of the inferior capsule is measurable through ultrasound examination and appears to be increased in shoulders with capsular contracture. Exploration of the inferior aspect of the shoulder joint could be added to shoulder US examination protocols for capsular contracture assessment even if other rotator cuff abnormalities are diagnosed by US. • Ultrasound is increasingly used to diagnose shoulder problems. • The thickness of the inferior glenohumeral ligament is measurable in the axilla. • The inferior glenohumeral ligament appears thickened in shoulders with capsular contracture. • Capsular contracture ultrasound features can be associated with other rotator cuff problems.

  10. Comparison of Thermal Safety Practice Guidelines for Diagnostic Ultrasound Exposures.

    PubMed

    Harris, Gerald R; Church, Charles C; Dalecki, Diane; Ziskin, Marvin C; Bagley, Jennifer E

    2016-02-01

    This article examines the historical evolution of various practice guidelines designed to minimize the possibility of thermal injury during a diagnostic ultrasound examination, including those published by the American Institute of Ultrasound in Medicine, British Medical Ultrasound Society and Health Canada. The guidelines for prenatal/neonatal examinations are in general agreement, but significant differences were found for postnatal exposures. We propose sets of thermal index versus exposure time for these examination categories below which there is reasonable assurance that an examination can be conducted without risk of producing an adverse thermal effect under any scanning conditions. If it is necessary to exceed these guidelines, the occurrence of an adverse thermal event is still unlikely in most situations because of mitigating factors such as transducer movement and perfusion, but the general principle of "as low as reasonably achievable" should be followed. Some limitations of the biological effects studies underpinning the guidelines also are discussed briefly. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Abdominal ultrasound and medical education.

    PubMed

    García de Casasola Sánchez, G; Torres Macho, J; Casas Rojo, J M; Cubo Romano, P; Antón Santos, J M; Villena Garrido, V; Diez Lobato, R

    2014-04-01

    Ultrasound is a very versatile diagnostic modality that permits real-time visualization of multiple internal organs. It is of invaluable help for the physical examination of the patients. To assess if ultrasound can be incorporated into medical education and if the students can perform a basic abdominal ultrasound examination without the necessity of a long period of training. Twelve medical students were trained in basic abdominal ultrasound during a 15-h training program including a 5-h theoretical and practical course and supervised practice in 20 selected patients. Subsequently, we conducted an evaluation test that assessed the ability of students to obtain the ultrasound views and to detect various pathologies in five different patients. The students were able to correctly identify the abdominal views more than 90% of the times. This percentage was only lower (80%) in the right subcostal view to locate the gallbladder. The accuracy or global efficiency of the ultrasound for the diagnosis of relevant pathological findings of the patients was greater than 90% (91.1% gallstones, abdominal aortic aneurysm 100%; splenomegaly 98.3%, ascites 100%; dilated inferior vena cava 100%; acute urinary retention 100%). The ultrasound may be a feasible learning tool in medical education. Ultrasound can help students to improve the physical examination. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  12. Dynamic Observation of the Morphological Changes in Paraurethral Ducts Infected with Gonococci in Men before and after Ceftriaxone Therapy Using High-Frequency Ultrasound.

    PubMed

    Fan, Wenge; Zhang, Qingsong; Ye, Xun; Fan, Zhijiang

    2018-01-01

    To observe the morphological changes in paraurethral ducts infected with gonococci in men before and after the administration of the ceftriaxone therapy using high-frequency ultrasound and determine its clinical significance. Thirty-two male patients with gonococcal paraurethral duct infection were enrolled. Their lesions were examined using an ACUSON X300 ultrasound system before and after they were subjected to ceftriaxone therapy. The paraurethral duct was completely closed 3-4 days after ceftriaxone treatment in 30 patients. Paraurethral duct closure began from the blind end and proceeded gradually towards its orifice; during closure, the paraurethral duct diameter showed no apparent change. These 30 patients whose paraurethral ducts closed were considered cured. In the remaining 2 patients, the length and diameter of the paraurethral ducts showed no change before and after ceftriaxone treatment; one patient was unresponsive to ceftriaxone treatment, and the other had secondary dilatation of the paraurethral duct. These 2 patients were cured after surgery. High-frequency ultrasound enables dynamic observation of the morphological changes in paraurethral ducts infected with gonococci before and after ceftriaxone therapy. High-frequency ultrasound can provide valuable information for incision, drainage, and wedge resection of paraurethral ducts. © 2017 S. Karger AG, Basel.

  13. Ultrasound Imaging of Muscle Contraction of the Tibialis Anterior in Patients with Facioscapulohumeral Dystrophy.

    PubMed

    Gijsbertse, Kaj; Goselink, Rianne; Lassche, Saskia; Nillesen, Maartje; Sprengers, André; Verdonschot, Nico; van Alfen, Nens; de Korte, Chris

    2017-11-01

    A need exists for biomarkers to diagnose, quantify and longitudinally follow facioscapulohumeral muscular dystrophy (FSHD) and many other neuromuscular disorders. Furthermore, the pathophysiological mechanisms leading to muscle weakness in most neuromuscular disorders are not completely understood. Dynamic ultrasound imaging (B-mode image sequences) in combination with speckle tracking is an easy, applicable and patient-friendly imaging tool to visualize and quantify muscle deformation. This dynamic information provides insight in the pathophysiological mechanisms and may help to distinguish the various stages of diseased muscle in FSHD. In this proof-of-principle study, we applied a speckle tracking technique to 2-D ultrasound image sequences to quantify the deformation of the tibialis anterior muscle in patients with FSHD and in healthy controls. The resulting deformation patterns were compared with muscle ultrasound echo intensity analysis (a measure of fat infiltration and dystrophy) and clinical outcome measures. Of the four FSHD patients, two patients had severe peroneal weakness and two patients had mild peroneal weakness on clinical examination. We found a markedly varied muscle deformation pattern between these groups: patients with severe peroneal weakness showed a different motion pattern of the tibialis anterior, with overall less displacement of the central tendon region, while healthy patients showed a non-uniform displacement pattern, with the central aponeurosis showing the largest displacement. Hence, dynamic muscle ultrasound of the tibialis anterior muscle in patients with FSHD revealed a distinctively different tissue deformation pattern among persons with and without tibialis anterior weakness. These findings could clarify the understanding of the pathophysiology of muscle weakness in FSHD patients. In addition, the change in muscle deformation shows good correlation with clinical measures and quantitative muscle ultrasound measurements. In conclusion, dynamic ultrasound in combination with speckle tracking allows the study of the effects of muscle pathology in relation to strength, force transmission and movement generation. Although further research is required, this technique can develop into a biomarker to quantify muscle disease severity. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Cognitive load imposed by knobology may adversely affect learners' perception of utility in using ultrasonography to learn physical examination skills, but not anatomy.

    PubMed

    Jamniczky, Heather A; McLaughlin, Kevin; Kaminska, Malgorzata E; Raman, Maitreyi; Somayaji, Ranjani; Wright, Bruce; Ma, Irene W Y

    2015-01-01

    Ultrasonography is increasingly used for teaching anatomy and physical examination skills but its effect on cognitive load is unknown. This study aimed to determine ultrasound's perceived utility for learning, and to investigate the effect of cognitive load on its perceived utility. Consenting first-year medical students (n = 137) completed ultrasound training that includes a didactic component and four ultrasound-guided anatomy and physical examination teaching sessions. Learners then completed a survey on comfort with physical examination techniques (three items; alpha = 0.77), perceived utility of ultrasound in learning (two items; alpha = 0.89), and cognitive load on ultrasound use [measured with a validated nine-point scale (10 items; alpha = 0.88)]. Learners found ultrasound useful for learning for both anatomy and physical examination (mean 4.2 ± 0.9 and 4.4 ± 0.8, respectively; where 1 = very useless and 5 = very useful). Principal components analysis on the cognitive load survey revealed two factors, "image interpretation" and "basic knobology," which accounted for 60.3% of total variance. Weighted factor scores were not associated with perceived utility in learning anatomy (beta = 0.01, P = 0.62 for "image interpretation" and beta = -0.04, P = 0.33 for "basic knobology"). However, factor score on "knobology" was inversely associated with perceived utility for learning physical examination (beta = -0.06; P = 0.03). While a basic introduction to ultrasound may suffice for teaching anatomy, more training may be required for teaching physical examination. Prior to teaching physical examination skills with ultrasonography, we recommend ensuring that learners have sufficient knobology skills. © 2014 American Association of Anatomists.

  15. [Abdominal ultrasound abnormalities incidentally discovered in patients with asymptomatic HIV in Lome (Togo)].

    PubMed

    Sonhaye, L; Tchaou, M; Amadou, A; Gbande, P; Assih, K; Djibril, M; Adjenou, K; Redah, D; N'Dakéna, K

    2014-01-01

    Few studies have examined ultrasound imaging of abdominal manifestations of HIV-AIDS, although these rank second only to its pleuropulmonary manifestations. Thus, this study sought to determine the features of abdominal ultrasound in HIV infection. This prospective, descriptive and analytical study took place in the radiology department of the University Hospital Campus Lomé and covered the three-year period of 2009-2011. It included all patients older than 15 years with positive HIV serology. During the study period, 566 patients met the inclusion criteria. Ultrasound examination showed the liver appeared normal in 153 patients (27.0%), but homogeneously hyperechoic and thus suggestive of hepatic steatosis in 107 (18.9%). The bile duct was dilatated in 12 patients or 2.1%. An anomaly in the corticomedullary differentiation in normal-sized kidneys was noted in 28.1% (159 patients). Diffuse homogeneous hypertrophy of the pancreas was found in 3 patients (0.53%). Splenomegaly was noted in 387 patients (68.4%); the echopattern of the spleen was diffusely micronodular in 6 patients (1.1%). Deep adenopathies were found in 29 patients (5.1%) and ascites in 46 patients (8.1%). Abdominal ultrasound is a medical imaging technique available in developing countries, less expensive than others, which can be considered an alternative to computed tomography (CT) in the countries of sub-Saharan Africa for the exploration of the abdominal manifestations of HIV.

  16. Ultrasound of Jugular Veins for Assessment of Acute Dyspnea in Emergency Departments and for the Assessment of Acute Heart Failure.

    PubMed

    Tzadok, Batsheva; Shapira, Shay; Tal-Or, Eran

    2018-05-01

    When a patient arrives at the emergency department (ED) presenting with symptoms of acute decompensated heart failure (ADHF), it is possible to reach a definitive diagnosis through many different venues, including medical history, physical examination, echocardiography, chest X-ray, and B-type natriuretic peptide (BNP) levels. Point-of-care ultrasound (POCUS) has become a mainstream tool for diagnosis and treatment in the field of emergency medicine, as well as in various other departments in the hospital setting. Currently, the main methods of diagnosis of ADHF using POCUS are pleural B-lines and inferior vena cava (IVC) width and respiratory variation. To examine the potential use and benefits of bedside ultrasound of the jugular veins in the evaluation of dyspneic patients for identification of ADHF. A blood BNP level was drawn from each participant at time of recruitment. The area and size of the internal jugular vein (IJV) during inspiration and expiration were examined. Our results showed that the respiratory area change of the IJVs had a specificity and sensitivity of nearly 70% accuracy rate in indentifying ADHF in our ED. Ultrasound of the IJV may be a useful tool for the diagnosis of ADHF because it is easy to measure and requires little skill. It is also not affected by patient body habitus.

  17. The potential role of elastography in differentiating between endometrial polyps and submucosal fibroids: a preliminary study

    PubMed Central

    2015-01-01

    Endometrial polyps and submucosal fibroids are common causes of abnormal uterine bleeding (AUB) and less commonly infertility. The prevalence of such intrauterine lesions increases with age during the reproductive years, and usually decreases after menopause. The first-line imaging examination in the diagnosis of endometrial polyps as well as submucosal fibroidsis ultrasound, but its accuracy is not obvious. Elastography is an ultrasound-based imaging modality that is used to assess the stiffness of examined tissues. Considering the fact that endometrial polyps derive from soft endometrial tissue and submucosal fibroids are made of hard muscle tissue, elastography seems a perfect tool to differentiate between such lesions. I present two groups of patients with AUB and intrauterine lesions suspected on ultrasound. In the first group of patients, elastography showed that the stiffness of the lesion was similar to the endometrium and softer than the myometrium. During hysteroscopies endometrial polyps were removed. In the second group of patients, elastography showed that the stiffness of the lesion was similar to the myometrium and harder than the endometrium. During hysteroscopies submucosal fibroids were removed. In both groups, the diagnosis was confirmed by the pathological examination in all cases. It was demonstrated that with the use of elastography it is possible to assess the stiffness of intrauterine lesions, which may be useful in differentiating between endometrial polyps and submucosal fibroids. PMID:26327901

  18. The potential role of elastography in differentiating between endometrial polyps and submucosal fibroids: a preliminary study.

    PubMed

    Woźniak, Sławomir

    2015-06-01

    Endometrial polyps and submucosal fibroids are common causes of abnormal uterine bleeding (AUB) and less commonly infertility. The prevalence of such intrauterine lesions increases with age during the reproductive years, and usually decreases after menopause. The first-line imaging examination in the diagnosis of endometrial polyps as well as submucosal fibroidsis ultrasound, but its accuracy is not obvious. Elastography is an ultrasound-based imaging modality that is used to assess the stiffness of examined tissues. Considering the fact that endometrial polyps derive from soft endometrial tissue and submucosal fibroids are made of hard muscle tissue, elastography seems a perfect tool to differentiate between such lesions. I present two groups of patients with AUB and intrauterine lesions suspected on ultrasound. In the first group of patients, elastography showed that the stiffness of the lesion was similar to the endometrium and softer than the myometrium. During hysteroscopies endometrial polyps were removed. In the second group of patients, elastography showed that the stiffness of the lesion was similar to the myometrium and harder than the endometrium. During hysteroscopies submucosal fibroids were removed. In both groups, the diagnosis was confirmed by the pathological examination in all cases. It was demonstrated that with the use of elastography it is possible to assess the stiffness of intrauterine lesions, which may be useful in differentiating between endometrial polyps and submucosal fibroids.

  19. High-intensity focused ultrasound ablation for treatment of hepatocellular carcinoma and hypersplenism: preliminary study.

    PubMed

    Zhu, Jing; Zhu, Hui; Mei, Zhechuan; Jin, Chengbing; Ran, Lifeng; Zhou, Kun; Yang, Wei; Zhang, Lian; She, Chaokun

    2013-10-01

    The purpose of this work was to preliminarily investigate the efficacy and safety of high-intensity focused ultrasound treatment of hepatocellular carcinoma and hypersplenism. Nine patients with hepatocellular carcinoma complicated by hypersplenism (5 male and 4 female; median age, 56 years; range, 51-66 years) were treated with ultrasound-guided high-intensity focused ultrasound. Complications were recorded. Laboratory examination and magnetic resonance imaging were used to evaluate the efficacy. After high-intensity focused ultrasound treatment, mean spleen ablation ± SD of 28.76% ± 6.1% was discovered; meanwhile, the white blood cell count, platelet count, and liver function of the patients were substantially improved during the follow-up period. In addition, symptoms such as epistaxis and gingival bleeding were ameliorated or even eliminated, and the quality of life was improved. Follow-up imaging showed a nonperfused volume in the spleen and an absence of a tumor blood supply at the treated lesions in the liver. For the first time to our knowledge, high-intensity focused ultrasound ablation was used to treat hepatocellular carcinoma complicated by hypersplenism. High-intensity focused ultrasound may be an effective and safe alternative for treatment of hepatocellular carcinoma complicated by hypersplenism, but further studies are necessary to clarify the mechanisms.

  20. Needle tip visibility in 3D ultrasound images

    NASA Astrophysics Data System (ADS)

    Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo

    2017-03-01

    Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.

  1. Droplets, Bubbles and Ultrasound Interactions.

    PubMed

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  2. Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

    NASA Technical Reports Server (NTRS)

    Dulchavsky, S. A.; Henry, S. E.; Moed, B. R.; Diebel, L. N.; Marshburn, T.; Hamilton, D. R.; Logan, J.; Kirkpatrick, A. W.; Williams, D. R.

    2002-01-01

    Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

  3. [The Hungarian adaptation and potential use of the Maternal-Fetal Attachment Scale questionnaire measuring mother-to-fetus attachment during ultrasound communication examinations].

    PubMed

    Andrek, Andrea; Hadházi, Éva; Kekecs, Zoltán

    2016-05-15

    Research measuring the effectiveness of communication during ultrasound examinations draw attention to its use in strengthening the bond between mother and fetus. Hungarian adaptation of the Maternal-Fetal Attachment Scale, which is the most commonly used tool for measuring intrauterine attachment. 114 pregnant women in the second or third trimester filled out the Hungarian version of the Maternal-Fetal Attachment Scale and an application form. The questionnaire showed excellent internal consistency, with a Cronbach's alpha of 0.87 for the total score. Married women scored significantly higher and scores increased as pregnancy progressed. Uncertainty surrounding the fetus's gender influenced attachment in the negative direction. There was no significant relationship between attachment total scores and a number of psycho-social factors. In the family-centered prenatal care the Maternal-Fetal Attachment Scale is a suitable tool to analyze ultrasound screening situations that strengthen the bond between mother and fetus.

  4. Experimental study of sector and linear array ultrasound accuracy and the influence of navigated 3D-reconstruction as compared to MRI in a brain tumor model.

    PubMed

    Siekmann, Max; Lothes, Thomas; König, Ralph; Wirtz, Christian Rainer; Coburger, Jan

    2018-03-01

    Currently, intraoperative ultrasound in brain tumor surgery is a rapidly propagating option in imaging technology. We examined the accuracy and resolution limits of different ultrasound probes and the influence of 3D-reconstruction in a phantom and compared these results to MRI in an intraoperative setting (iMRI). An agarose gel phantom with predefined gel targets was examined with iMRI, a sector (SUS) and a linear (LUS) array probe with two-dimensional images. Additionally, 3D-reconstructed sweeps in perpendicular directions were made of every target with both probes, resulting in 392 measurements. Statistical calculations were performed, and comparative boxplots were generated. Every measurement of iMRI and LUS was more precise than SUS, while there was no apparent difference in height of iMRI and 3D-reconstructed LUS. Measurements with 3D-reconstructed LUS were always more accurate than in 2D-LUS, while 3D-reconstruction of SUS showed nearly no differences to 2D-SUS in some measurements. We found correlations of 3D-reconstructed SUS and LUS length and width measurements with 2D results in the same image orientation. LUS provides an accuracy and resolution comparable to iMRI, while SUS is less exact than LUS and iMRI. 3D-reconstruction showed the potential to distinctly improve accuracy and resolution of ultrasound images, although there is a strong correlation with the sweep direction during data acquisition.

  5. Does use of a PACS increase the number of images per study? A case study in ultrasound.

    PubMed

    Horii, Steven; Nisenbaum, Harvey; Farn, James; Coleman, Beverly; Rowling, Susan; Langer, Jill; Jacobs, Jill; Arger, Peter; Pinheiro, Lisa; Klein, Wendy; Reber, Michele; Iyoob, Christopher

    2002-03-01

    The purpose of this study was to determine if the use of a picture archiving and communications system (PACS) in ultrasonography increased the number of images acquired per examination. The hypothesis that such an increase does occur was based on anecdotal information; this study sought to test the hypothesis. A random sample of all ultrasound examination types was drawn from the period 1998 through 1999. The ultrasound PACS in use (ACCESS; Kodak Health Information Systems, Dallas, TX) records the number of grayscale and color images saved as part of each study. Each examination in the sample was checked in the ultrasound PACS database,.and the number of grayscale and color images was recorded. The comparison film-based sample was drawn from the period 1994 through 1995. The number of examinations of each type selected was based on the overall statistics of the section; that is, the sample was designed to represent the approximate frequency with which the various examination types are done. For film-based image counts, the jackets were retrieved, and the number of grayscale and color images were counted. The number of images obtained per examination (for most examinations) in ultrasound increased with PACS use. This was more evident with some examination types (eg, pelvis). This result, however, has to be examined for possible systematic biases because ultrasound practice has changed over the time since the authors stopped using film routinely. The use of PACS in ultrasonography was not associated with an increase in the number of images per examination based solely on the use of PACS, with the exception of neonatal head studies. Increases in the number of images per study was otherwise associated with examinations for which changes in protocols resulted in the increased image counts.

  6. Does acoustic radiation force elastography improve the diagnostic capability of ultrasound in the preoperative characterization of masses of the parotid gland?

    PubMed

    Zengel, Pamela; Notter, Florian; Clevert, Dirk A

    2018-06-06

    Ultrasound is the method of choice for preoperative evaluation of tumours of the parotid glands. However, existing methods do not allow for clear differentiation between the most common benign tumours and malignant tumours. The aim of our study was to evaluate if acoustic radiation force, Virtual Touch Quantification (VTQ) elastography helps to improve the preoperative evaluation of parotid masses. We investigated the parenchyma of 102 parotid glands, 14 lymph nodes of healthy volunteers and 51 tumours of the parotid gland via ultrasound, colour Doppler ultrasound and VTQ. The results were matched with histopathology and analyzed. The perfusion in pleomorphic adenoma, the most frequent benign tumour of the parotid gland, was significantly lower in comparison to malignant tumours. All tumours showed statistically significant higher perfusion in comparison to the parenchyma or the lymph nodes of the gland. Shear wave velocity of the user-defined region of interest was statistically significant more frequently an overflow value higher than 8.5 m/s in total tumours in comparison to parenchyma or lymph nodes. The different tumour types presented no significant difference in the shear wave velocity. VTQ in combination with classical ultrasound examination provides additional data useful in distinguishing between benign and malignant tumours and thus shows promise for integration into preexisting ultrasound protocols. However, despite the improvement, clear differentiation of tumours is still not possible and further investigation is recommended.

  7. Antenatal diagnosis of anophthalmia by three-dimensional ultrasound: a novel application of the reverse face view.

    PubMed

    Wong, H S; Parker, S; Tait, J; Pringle, K C

    2008-07-01

    The prenatal diagnosis of anophthalmia can be made on the demonstration of absent eye globe and lens on the affected side(s) on two-dimensional ultrasound examination, but when the fetal head position is unfavorable three-dimensional (3D) ultrasound may reveal additional diagnostic sonographic features, including sunken eyelids and small or hypoplastic orbit on the affected side(s). We present two cases of isolated anophthalmia diagnosed on prenatal ultrasound examination in which 3D ultrasound provided additional diagnostic information. The reverse face view provides valuable information about the orbits and the eyeballs for prenatal diagnosis and assessment of anophthalmia.

  8. Ultrasound-mediated transdermal drug delivery of fluorescent nanoparticles and hyaluronic acid into porcine skin in vitro

    NASA Astrophysics Data System (ADS)

    Wang, Huan-Lei; Fan, Peng-Fei; Guo, Xia-Sheng; Tu, Juan; Ma, Yong; Zhang, Dong

    2016-12-01

    Transdermal drug delivery (TDD) can effectively bypass the first-pass effect. In this paper, ultrasound-facilitated TDD on fresh porcine skin was studied under various acoustic parameters, including frequency, amplitude, and exposure time. The delivery of yellow-green fluorescent nanoparticles and high molecular weight hyaluronic acid (HA) in the skin samples was observed by laser confocal microscopy and ultraviolet spectrometry, respectively. The results showed that, with the application of ultrasound exposures, the permeability of the skin to these markers (e.g., their penetration depth and concentration) could be raised above its passive diffusion permeability. Moreover, ultrasound-facilitated TDD was also tested with/without the presence of ultrasound contrast agents (UCAs). When the ultrasound was applied without UCAs, low ultrasound frequency will give a better drug delivery effect than high frequency, but the penetration depth was less likely to exceed 200 μm. However, with the help of the ultrasound-induced microbubble cavitation effect, both the penetration depth and concentration in the skin were significantly enhanced even more. The best ultrasound-facilitated TDD could be achieved with a drug penetration depth of over 600 μm, and the penetration concentrations of fluorescent nanoparticles and HA increased up to about 4-5 folds. In order to get better understanding of ultrasound-facilitated TDD, scanning electron microscopy was used to examine the surface morphology of skin samples, which showed that the skin structure changed greatly under the treatment of ultrasound and UCA. The present work suggests that, for TDD applications (e.g., nanoparticle drug carriers, transdermal patches and cosmetics), protocols and methods presented in this paper are potentially useful. Project partially supported by the National Natural Science Foundation of China (Grant Nos. 81127901, 81227004, 81473692, 81673995, 11374155, 11574156, 11274170, 11274176, 11474001, 11474161, 11474166, and 11674173), the Natural Science Foundation of Jiangsu Province, China (Grant No. BK2011812), the Fundamental Research Funds for the Central Universities, and the National High-Tech Research and Development Program of China (Grant No. 2012AA022702).

  9. How to set up a low cost tele-ultrasound capable videoconferencing system with wide applicability

    PubMed Central

    2012-01-01

    Background Worldwide ultrasound equipment accessibility is at an all-time high, as technology improves and costs decrease. Ensuring that patients benefit from more accurate resuscitation and diagnoses from a user-dependent technology, such as ultrasound, requires accurate examination, typically entailing significant training. Remote tele-mentored ultrasound (RTUS) examination is, however, a technique pioneered in space medicine that has increased applicability on earth. We, thus, sought to create and demonstrate a cost-minimal approach and system with potentially global applicability. Methods The cost-minimal RTUS system was constructed by utilizing a standard off-the-shelf laptop computer that connected to the internet through an internal wireless receiver and/or was tethered through a smartphone. A number of portable hand-held ultrasound devices were digitally streamed into the laptop utilizing a video converter. Both the ultrasound video and the output of a head-mounted video camera were transmitted over freely available Voice Over Internet Protocol (VOIP) software to remote experts who could receive and communicate using any mobile device (computer, tablet, or smartphone) that could access secure VOIP transmissions from the internet. Results The RTUS system allowed real-time mentored tele-ultrasound to be conducted from a variety of settings that were inside buildings, outside on mountainsides, and even within aircraft in flight all unified by the simple capability of receiving and transmitting VOIP transmissions. . Numerous types of ultrasound examinations were conducted such as abdominal and thoracic examinations with a variety of users mentored who had previous skills ranging from none to expert. Internet connectivity was rarely a limiting factor, with competing logistical and scheduling demands of the participants predominating. Conclusions RTUS examinations can educate and guide point of care clinical providers to enhance their use of ultrasound. The scope of the examinations conducted is limited only by the time available and the criticality of the subject being examined. As internet connectivity will only improve worldwide, future developments need to focus on the human factors to optimize tele-sonographic interactions. PMID:22871099

  10. Ultrasound definition of tendon damage in patients with rheumatoid arthritis. Results of a OMERACT consensus-based ultrasound score focussing on the diagnostic reliability.

    PubMed

    Bruyn, George A W; Hanova, Petra; Iagnocco, Annamaria; d'Agostino, Maria-Antonietta; Möller, Ingrid; Terslev, Lene; Backhaus, Marina; Balint, Peter V; Filippucci, Emilio; Baudoin, Paul; van Vugt, Richard; Pineda, Carlos; Wakefield, Richard; Garrido, Jesus; Pecha, Ondrej; Naredo, Esperanza

    2014-11-01

    To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Bronchoalveolar lavage for the treatment of neonatal pulmonary atelectasis under lung ultrasound monitoring.

    PubMed

    Liu, Jing; Ren, Xiao-Ling; Fu, Wei; Liu, Ying; Xia, Rong-Ming

    2017-10-01

    Pulmonary atelectasis (PA) is a common clinical complication among newborns, and it is one of the most common causes of neonatal dyspnea, a condition with no specific effective treatment. This study examined the effectiveness and security of bronchoalveolar lavage (BL) regarding the treatment of neonatal PA under ultrasound monitoring. A total of 57 patients diagnosed with PA via lung ultrasound (LUS) were included in this study. All patients received BL via a tracheal intubation injection of lavage fluid. The LUS was conducted immediately after each lavage to understand the conditions of lung re-expansion. Irrigation was repeated two to three times as one course of treatment. BL was provided as one to two courses of treatment daily for several days according to atelectasis and lung recruitment status. Of the 57 patients, BL was very effective in 44 cases (77.2%), marginally effective in nine cases (15.8%) and ineffective in four cases (7.0%), showing a total effective rate of 93.0%. The four ineffective cases showed a long disease duration and severe pulmonary consolidation. BL showed significant effectiveness for the treatment of neonatal PA under ultrasound monitoring. This treatment is easy to operate, and no adverse side effects were observed. Thus, BL should be considered for clinical application.

  12. The use of ultrasound in the diagnosis of abdominal wall hernias.

    PubMed

    Young, J; Gilbert, A I; Graham, M F

    2007-08-01

    The diagnosis of abdominal wall hernias is not always straightforward and may require additional investigative modalities. Real-time ultrasound is accurate, non-invasive, relatively inexpensive, and readily available. The value of ultrasound as an adjunctive tool in the diagnosis of abdominal wall hernias in both pre-operative and post-operative patients was studied. Retrospective analysis of 200 patients treated at the Hernia Institute of Florida was carried out. In these cases, ultrasound had been used to assist with case management. Patients without previous hernia surgery and those with early and late post-herniorrhaphy complaints were studied. Patients with obvious hernias were excluded. Indications for ultrasound examination included patients with abdominal pain without a palpable hernia, a palpable mass of questionable etiology, and patients with inordinate pain or excessive swelling during the early post-operative period. Patients were treated with surgery or conservative therapy depending on the results of the physical examination and ultrasound studies. Cases in which the ultrasound findings influenced the decision-making process by confirming clinical findings or altering the diagnosis and changing the treatment plan are discussed. Of the 200 patients, 144 complained of pain alone and on physical exam no hernia or mass was palpable. Of these 144 patients with pain alone, 21 had a hernia identified on the US examination and were referred for surgery. The 108 that had a negative ultrasound were treated conservatively with rest, heat, and anti-inflammatory drugs, most often with excellent results. Of the 56 remaining patients who had a mass, with or without pain, 22 had hernias identified by means of ultrasound examination. In the other 34, the etiology of the mass was not a hernia. Abdominal wall ultrasound is a valuable tool in the scheme of management of patients in whom the diagnosis of abdominal wall hernia is unclear. Therapeutic decisions can be influenced by the ultrasound findings that can provide more efficient and economical treatment by expediting their clinical management.

  13. Guidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization. Methods/Design The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections. Discussion The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications. Trial registration ClinicalTrials.gov Identifier: NCT01888094 PMID:24885789

  14. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    PubMed

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Goal-directed ultrasound in the detection of long-bone fractures

    NASA Technical Reports Server (NTRS)

    Marshburn, Thomas H.; Legome, Eric; Sargsyan, Ashot; Li, Shannon Melton James; Noble, Vicki A.; Dulchavsky, Scott A.; Sims, Carrie; Robinson, David

    2004-01-01

    BACKGROUND: New portable ultrasound (US) systems are capable of detecting fractures in the remote setting. However, the accuracy of ultrasound by physicians with minimal ultrasound training is unknown. METHODS: After one hour of standardized training, physicians with minimal US experience clinically evaluated patients presenting with pain and trauma to the upper arm or leg. The investigators then performed a long-bone US evaluation, recording their impression of fracture presence or absence. Results of the examination were compared with routine plain or computer aided radiography (CT). RESULTS: 58 patients were examined. The sensitivity and specificity of US were 92.9% and 83.3%, and of the physical examination were 78.6% and 90.0%, respectively. US provided improved sensitivity with less specificity compared with physical examination in the detection of fractures in long bones. CONCLUSION: Ultrasound scans by minimally trained clinicians may be used to rule out a long-bone fracture in patients with a medium to low probability of fracture.

  16. Adiposis dolorosa (Dercum's disease): MRI and ultrasound appearances.

    PubMed

    Tins, B J; Matthews, C; Haddaway, M; Cassar-Pullicino, V N; Lalam, R; Singh, J; Tyrrell, P N M

    2013-10-01

    To describe ultrasound and magnetic resonance imaging (MRI) features of adiposis dolorosa, Dercum's disease, and to evaluate the MRI features prospectively against a large number of MRI examinations. Institutional review board approval for this study was obtained. The imaging features at MRI and ultrasound of 13 cases of adiposis dolorosa (nine female, four male; age range 32-72 years) were reviewed. MRI findings typical for adiposis dolorosa were proposed and prospectively evaluated on 6247 MRI examinations performed over a period of 8 months. Adiposis dolorosa demonstrates multiple, oblong, fatty lesions in the superficial subcutaneous fatty tissue. They are mostly <2 cm in long axis diameter. They demonstrate nodular ("blush-like") increased fluid signal at unenhanced MRI and are markedly hyperechoic at ultrasound. There is no contrast medium enhancement at MRI and no increased Doppler signal at ultrasound. Most lesions were clinically asymptomatic, some were painful/tender. There was no imaging evidence of oedema or inflammation. During prospective validation of these MRI features on 6247 MRI examinations, two cases with typical imaging features were encountered; both were diagnosed as adiposis dolorosa on clinical review. All cases of adiposis dolorosa showed these imaging findings. This results in a very low likelihood that a nodular, blush-like appearance of subcutaneous fat on MRI is not due to adiposis dolorosa. Adiposis dolorosa, Dercum's disease, should be suggested in the presence of multiple (many) small, oblong, fatty lesions in the subcutaneous fatty tissue in adult patients if they are hyperechoic on ultrasound imaging or blush-like at unenhanced MRI; typically a small number of these lesions are tender/painful. Imaging does not demonstrate inflammation or oedema in relation to these lesions. These MRI features should suggest the diagnosis and are likely to be pathognomonic. The radiologist is often the first to suggest the diagnosis based on the imaging features. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  17. Holistic ultrasound in trauma: An update.

    PubMed

    Saranteas, Theodosios; Mavrogenis, Andreas F

    2016-10-01

    Holistic ultrasound is a total body examination using an ultrasound device aiming to achieve immediate patient care and decision making. In the setting of trauma, it is one of the most fundamental components of care of the injured patients. Ground-breaking imaging software allows physicians to examine various organs thoroughly, recognize imaging signs early, and potentially foresee the onset or the possible outcome of certain types of injuries. Holistic ultrasound can be performed on a routine basis at the bedside of the patients, at admission and during the perioperative period. Trauma care physicians should be aware of the diagnostic and guidance benefits of ultrasound and should receive appropriate training for the optimal management of their patients. In this paper, the findings of holistic ultrasound in trauma patients are presented, with emphasis on the lungs, heart, cerebral circulation, abdomen, and airway. Additionally, the benefits of ultrasound imaging in interventional anaesthesia techniques such as ultrasound-guided peripheral nerve blocks and central vein catheterization are described. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Utility of rapid database searching for quality assurance: 'detective work' in uncovering radiology coding and billing errors

    NASA Astrophysics Data System (ADS)

    Horii, Steven C.; Kim, Woojin; Boonn, William; Iyoob, Christopher; Maston, Keith; Coleman, Beverly G.

    2011-03-01

    When the first quarter of 2010 Department of Radiology statistics were provided to the Section Chiefs, the authors (SH, BC) were alarmed to discover that Ultrasound showed a decrease of 2.5 percent in billed examinations. This seemed to be in direct contradistinction to the experience of the ultrasound faculty members and sonographers. Their experience was that they were far busier than during the same quarter of 2009. The one exception that all acknowledged was the month of February, 2010 when several major winter storms resulted in a much decreased Hospital admission and Emergency Department visit rate. Since these statistics in part help establish priorities for capital budget items, professional and technical staffing levels, and levels of incentive salary, they are taken very seriously. The availability of a desktop, Web-based RIS database search tool developed by two of the authors (WK, WB) and built-in database functions of the ultrasound miniPACS, made it possible for us very rapidly to develop and test hypotheses for why the number of billable examinations was declining in the face of what experience told the authors was an increasing number of examinations being performed. Within a short time, we identified the major cause as errors on the part of the company retained to verify billable Current Procedural Terminology (CPT) codes against ultrasound reports. This information is being used going forward to recover unbilled examinations and take measures to reduce or eliminate the types of coding errors that resulted in the problem.

  19. Tele-ultrasound and paramedics: real-time remote physician guidance of the Focused Assessment With Sonography for Trauma examination.

    PubMed

    Boniface, Keith S; Shokoohi, Hamid; Smith, E Reed; Scantlebury, Kari

    2011-06-01

    The aim of this study was to examine the capability of ultrasound-naïve paramedics to obtain interpretable Focused Assessment With Sonography for Trauma (FAST) images under the remote direction of emergency physicians (EPs). Paramedics without experience using ultrasound participated in a 20-minute lecture covering orientation to the ultrasound machine and the FAST examination. The paramedics subsequently performed FAST examinations on a model patient, whereas the EP remained in another room, out of visual contact. The EP communicated with the paramedic via radio, viewing video from the ultrasound machine on a monitor and directing the probe movements to obtain the views of the FAST examination. We examined the success rate, time to complete the examinations, and adequacy of images from the paramedics' first FAST examination. Fifty-one paramedics performed their first FAST examinations and were able to successfully complete 100% of the views of the FAST. The median time from probe placement to examination completion was 262 seconds (interquartile range, 206-343 seconds). The median time to complete right upper quadrant (RUQ) versus left upper quadrant (LUQ) views was 39 and 50 seconds, respectively. The time to complete the LUQ scan took significantly longer than the RUQ (P < .01). Paramedics completed cardiac and pelvic view in a median time of 42 and 25 seconds, respectively. The study demonstrated that paramedics with no prior ultrasound experience could obtain FAST images under remote guidance from experienced EPs in less than 5 minutes. Given rapidly evolving data transmission technology, this has applicability in battlefield, remote, and rural prehospital settings. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Prenatal diagnosis of monocephalic bifacial tetraophthalmic diprosopus (conjoined twin).

    PubMed

    Dhaifalah, I; Curtisova, V; Santavy, J

    2008-01-01

    A case of diprosopus twinning which is rare conjoined twinning is reported prenatally at 22 weeks' gestation. 2D ultrasound examinations showed duplication of the craniofacial structures with four hemispheres, two cerebella and two thalami. There were three orbits two external ears, two noses, fused adjacent maxilla and two oral cavities with two fused oral opening and two jaws. The woman did not consent to any further investigations and the pregnancy was terminated. The postmortem examination confirmed the diagnosis in a male fetus with a crown-rump length of 155 mm, weighing 450 g. The body appeared normal except for a small poorly formed rudiment of a supernumerary digit next to the thumb of the right hand. The ultrasound examination and postmortem finding of this case is described with a short review of the literature. (c) 2007 S. Karger AG, Basel

  1. Impact of Music in Reducing Patient Anxiety During Pediatric Ultrasound

    PubMed Central

    Kesselman, Andrew; Bergen, Michael; Stefanov, Dimitre; Goldfisher, Rachelle; Amodio, John

    2016-01-01

    The use of noninvasive ultrasound examinations can potentially result in significant anxiety in the pediatric population. The purpose of this study was to assess the influence of music during pediatric ultrasound examinations to reduce anxiety measured by heart rate. A total of 44 patients were recruited; 21 controls and 23 experimental. Each participant was randomized to either music or no music (control) after parental consent was obtained. Pulse oximeters were used to monitor heart rate at 15 second intervals for a total of 1 minute, with mean values calculated prior to entering the procedure room, during the middle of the procedure, and after the procedure was completed. The total scan time was determined from the initial image acquisition until the last image recorded by the ultrasound technologist. At the completion of each procedure, the ultrasound technologist scored the ease of performance for the scan on a subjective scale of 1-10 based on prior experience. When utilizing music during pediatric ultrasounds examinations, our study demonstrated significantly decreased heart rate variability from pre-procedural to post-procedural periods. There was no statistical significant difference in total scan time or ultrasound technologist scoring between the two groups. This study demonstrates that music is an inexpensive and effective means of reducing anxiety during pediatric ultrasound as indicated by heart rate. PMID:27114817

  2. [Quality standards for ultrasound assessment of the superficial venous system of the lower limbs. Report of the French Society for Vascular Medicine].

    PubMed

    Auvert, J-F; Chleir, F; Coppé, G; Hamel-Desnos, C; Moraglia, L; Pichot, O

    2014-02-01

    The quality standards of the French Society for Vascular Medicine for the ultrasound assessment of the superficial venous system of the lower limbs are based on the two following requirements: technical know-how (mastering the use of ultrasound devices and the method of examination); medical know-how (ability to adapt the methods and scope of the examination to its clinical indications and purpose and to rationally analyze and interpret its results). To describe an optimal method of examination in relation to the clinical question and hypothesis; to achieve consistent practice, methods, glossary terminologies and reporting; to provide good practice reference points and to promote a high quality process. The three levels of examination. Their clinical indications and goals. The reference standard examination (level 2) and its variants according to clinical needs. The minimal content of the examination report, the letter to the referring physician (synthesis, conclusion and management suggestions) and iconography. Commented glossary (anatomy, hemodynamics, semiology). Technical basis. Ultrasound devices settings. We discuss of use of Duplex ultrasound for the assessment of the superficial veins of the lower limbs in vascular medicine practice. Copyright © 2014. Published by Elsevier Masson SAS.

  3. Split-screen display system and standardized methods for ultrasound image acquisition and multi-frame data processing

    NASA Technical Reports Server (NTRS)

    Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)

    2011-01-01

    A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.

  4. Just-in-time cost-effective off-the-shelf remote telementoring of paramedical personnel in bedside lung sonography-a technical case study.

    PubMed

    Biegler, Nancy; McBeth, Paul B; Tevez-Molina, Martha C; McMillan, Janelle; Crawford, Innes; Hamilton, Douglas R; Kirkpatrick, Andrew W

    2012-12-01

    Remote telementored ultrasound (RTMUS) is a new discipline that allows a remote expert to guide variably experienced clinical responders through focused ultrasound examinations. We used the examination of the pleural spaces after tube thoracostomy (TT) removal by a nurse with no prior ultrasound experience as an illustrative but highly accurate example of the technique using a simple cost-effective system. The image outputs of a handheld ultrasound machine and a head-mounted Web camera were input into a customized graphical user interface and streamed over a freely available voice over Internet protocol system that allowed two-way audio and visual communication between the novice examiner and the remote expert. The bedside nurse was then guided to examine the anterior chest of a patient who had recently had bilateral TTs removed. The team sought to determine the presence or absence of any recurrent pneumothoraces using the standard criteria for the ultrasound diagnosis of post-removal pneumothorax (PTXs). An upright chest radiograph (CXR) was obtained immediately after the RTMUS examination. The RTMUS system enabled the novice user to learn how to hold the ultrasound probe, where to place it on the chest, and thereafter to diagnose a subtle unilateral PTX characterized as "tiny" on the subsequent formal CXR report. As ultrasound has almost limitless clinical utility, using simple but advanced informatics and communication technologies has potential to improve worldwide healthcare delivery. RTMUS could be used both to enhance the information content as well as to digitally document important physiologic findings in any clinical encounter wherever a portable ultrasound and Internet connectivity are available.

  5. Reducing Unnecessary Shoulder MRI Examinations Within a Capitated Health Care System: A Potential Role for Shoulder Ultrasound.

    PubMed

    Sheehan, Scott E; Coburn, John A; Singh, Hardeep; Vanness, David J; Sittig, Dean F; Moberg, D Paul; Safdar, Nasia; Lee, Kenneth S; Brunner, Michael C

    2016-07-01

    MRI is frequently overused. The aim of this study was to analyze shoulder MRI ordering practices within a capitated health care system and explore the potential effects of shoulder ultrasound substitution. We reviewed medical records of 237 consecutive shoulder MRI examinations performed in 2013 at a Department of Veterans Affairs tertiary care hospital. Using advanced imaging guidelines, we assessed ordering appropriateness of shoulder MRI and estimated the proportion of examinations for which musculoskeletal ultrasound could have been an acceptable substitute, had it been available. We then reviewed MRI findings and assessed if ultrasound with preceding radiograph would have been adequate for diagnosis, based on literature reports of shoulder ultrasound diagnostic performance. Of the 237 examinations reviewed, 106 (45%) were deemed to be inappropriately ordered, most commonly because of an absent preceding radiograph (n = 98; 92%). Nonorthopedic providers had a higher frequency of inappropriate ordering (44%) relative to orthopedic specialists (17%) (P = .016; odds ratio = 3.15, 95% confidence interval = 1.24-8.01). In the 237 examinations, ultrasound could have been the indicated advanced imaging modality for 157 (66%), and most of these (133/157; 85%) could have had all relevant pathologies characterized when combined with radiographs. Regardless of indicated modality, ultrasound could have characterized 80% of all cases ordered by nonorthopedic providers and 50% of cases ordered by orthopedic specialists (P = .007). Advanced shoulder imaging is often not ordered according to published appropriateness criteria. While nonorthopedic provider orders were more likely to be inappropriate, inappropriateness persisted among orthopedic providers. A combined ultrasound and radiograph evaluation strategy could accurately characterize shoulder pathologies for most cases. Published by Elsevier Inc.

  6. Adding ultrasound to clinical examination reduced frequency of enthesitis in primary care psoriasis patients with musculoskeletal complaints.

    PubMed

    van der Ven, Myrthe; Karreman, Maren C; Weel, Angelique E A M; Tchetverikov, Ilja; Vis, Marijn; Nijsten, Tamar E C; Hazes, Johanna M W; Luime, Jolanda J

    2016-01-01

    Part of the psoriasis patients with musculoskeletal complaints will have inflammation of the entheses. Entheseal inflammation is difficult to assess by clinical examination only. Therefore, we aimed to determine the frequency of clinically relevant ultrasound inflammation at the most commonly assessed entheses (MASEI; Madrid Sonographic Enthesis Index) in primary care psoriasis patients with one or more tender entheses. Adult primary care psoriasis patients with musculoskeletal complaints (tender enthesis or arthritis at physical examination) had an ultrasound examination of seven entheses according to the MASEI. Clinically relevant ultrasound inflammation was defined as active inflammation on ultrasound in combination with at least one clinical feature at the same enthesis. Active ultrasound inflammation contained positive power Doppler signal or in case of the plantar aponeurosis increased thickness. Structural changes entailed calcifications, enthesophytes, increased thickness, hypoechogeneicity indicating irregular fibre structure and erosions. Clinically, an enthesis was scored positive by a tender enthesis at clinical examination, reported pain in the history or self-reported pain in the questionnaires. Of 542 primary care psoriasis patient, 111 patients had tender entheses and/or arthritis. These patients were both clinically and ultrasonographically evaluated. Active ultrasound inflammation accompanied with pain or tenderness at the enthesis was found in 36% of the patients (n=40). Most common were inflammation at the knee (n=11) and at the plantar aponeurosis (n=10). Structural changes were observed in 95% of the psoriasis patients independent of their clinical manifestation. We found concurrent presence of ultrasound inflammatory changes and clinical symptoms in 36% of the primary care psoriasis patients who had tenderness at one or more entheseal sites.

  7. Ultrasonography of uterine leiomyomas

    PubMed Central

    Woźniak, Andrzej

    2017-01-01

    Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan – TVS) or transabdominally (transabdominal scan – TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus. PMID:29483851

  8. The Utility of Routine Ultrasound in the Diagnosis and Management of Adolescents with Abnormal Uterine Bleeding.

    PubMed

    Pecchioli, Yael; Oyewumi, Lamide; Allen, Lisa M; Kives, Sari

    2017-04-01

    Despite the fact that most cases of abnormal uterine bleeding (AUB) in adolescence are due to an immature hypothalamic-pituitary-ovarian (HPO) axis, the current approach to investigating adolescents who present with AUB often includes pelvic ultrasound to exclude rare structural causes. The aim of this study was to determine whether an ultrasound ordered for the investigation of AUB in adolescents detects any significant anatomic pathology or alters diagnosis and management. A retrospective chart review of 230 patients younger than 18 years of age who presented with AUB to the gynecology clinic at the Hospital for Sick Children in Toronto, Canada between January 2010 and December 2012 was completed. Findings on pelvic ultrasound and any further imaging as well as management choices for these patients were examined. Of all patients, 67.8% (156/230) had ultrasound done as part of their AUB workup. The most common diagnosis for the patients who received ultrasound examinations and the patients who did not was AUB due to an immature HPO axis. Of the patients who received an ultrasound examination, 72.4% (113/156) had normal findings; incidental findings were identified in 17.9% (28/156) and polycystic ovary syndrome morphology in 6.4% (10/156). Structural causes of AUB were found in only 2 (1.3%) of the adolescents imaged. No patient had a change in her AUB management plan because of ultrasound findings. Our results strongly suggest that pelvic ultrasound examination is not required in the initial investigation of AUB in the adolescent population because it did not alter treatment in any of our patients. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  9. Ultrasound for Distal Forearm Fracture: A Systematic Review and Diagnostic Meta-Analysis

    PubMed Central

    Douma-den Hamer, Djoke; Blanker, Marco H.; Edens, Mireille A.; Buijteweg, Lonneke N.; Boomsma, Martijn F.; van Helden, Sven H.; Mauritz, Gert-Jan

    2016-01-01

    Study Objective To determine the diagnostic accuracy of ultrasound for detecting distal forearm fractures. Methods A systematic review and diagnostic meta-analysis was performed according to the PRISMA statement. We searched MEDLINE, Web of Science and the Cochrane Library from inception to September 2015. All prospective studies of the diagnostic accuracy of ultrasound versus radiography as the reference standard were included. We excluded studies with a retrospective design and those with evidence of verification bias. We assessed the methodological quality of the included studies with the QUADAS-2 tool. We performed a meta-analysis of studies evaluating ultrasound to calculate the pooled sensitivity and specificity with 95% confidence intervals (CI95%) using a bivariate model with random effects. Subgroup and sensitivity analysis were used to examine the effect of methodological differences and other study characteristics. Results Out of 867 publications we included 16 studies with 1,204 patients and 641 fractures. The pooled test characteristics for ultrasound were: sensitivity 97% (CI95% 93–99%), specificity 95% (CI95% 89–98%), positive likelihood ratio (LR) 20.0 (8.5–47.2) and negative LR 0.03 (0.01–0.08). The corresponding pooled diagnostic odds ratio (DOR) was 667 (142–3,133). Apparent differences were shown for method of viewing, with the 6-view method showing higher specificity, positive LR, and DOR, compared to the 4-view method. Conclusion The present meta-analysis showed that ultrasound has a high accuracy for the diagnosis of distal forearm fractures in children when used by proper viewing method. Based on this, ultrasound should be considered a reliable alternative, which has the advantages of being radiation free. PMID:27196439

  10. Ultrasound in the diagnosis of palpable abdominal masses in children.

    PubMed

    Annuar, Z; Sakijan, A S; Annuar, N; Kooi, G H

    1990-12-01

    Ultrasound examinations were done to evaluate clinically palpable abdominal masses in 125 children. The examinations were normal in 21 patients. In 15 patients, the clinically palpable masses were actually anterior abdominal wall abscesses or hematomas. Final diagnosis was available in 87 of 89 patients with intraabdominal masses detected on ultrasound. The majority (71%) were retroperitoneal masses where two-thirds were of renal origin. Ultrasound diagnosis was correct in 68 patients (78%). All cases of hydronephrosis were correctly diagnosed based on characteristic ultrasound appearances. Correct diagnoses of all cases of adrenal hematoma, psoas abscess, liver hematoma, liver abscess and one case of liver metastases were achieved with correlation of relevant clinical information.

  11. Ultrasound evaluation of cortical brain development in fetuses with intrauterine growth restriction.

    PubMed

    Businelli, Caterina; de Wit, Charlotte; Visser, Gerard H A; Pistorius, Lourens R

    2014-09-10

    Abstract Objective: We evaluated the ultrasound appearance of brain volume and cortical development in fetuses with early growth restriction and placental insufficiency. Methods: We examined a cohort of 20 fetuses with severe intrauterine growth restriction (IUGR) and evidence of placental insufficiency by three-dimensional (3D) ultrasound between 24 and 34 weeks. We graded cortical development and measured the supratentorial intracranial volume. The cortical grading and volume were compared to data obtained from a reference population of 28 adequate for gestational age (AGA) fetuses. Results: Ultrasound examinations were performed in 20 fetuses with IUGR. The biometry and brain volume were significantly reduced in IUGR fetuses. There was evidence of accelerated cortical development in IUGR fetuses. Conclusion: This study confirms that the smaller brain volume in IUGR fetuses, with normal or accelerated cortical maturation as previously depicted with postnatal MRI examination, can be demonstrated by prenatal 3D ultrasound.

  12. The influence of external ultrasound on the histologic architecture of the organic capsule around smooth silicone implants: experimental study in rats.

    PubMed

    Mendes, F H; Viterbo, F; DeLucca, L

    2008-05-01

    Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules. In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into "ultrasound" and "control" groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light. Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization. The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.

  13. The Role of Ultrasound Imaging of Callus Formation in the Treatment of Long Bone Fractures in Children.

    PubMed

    Wawrzyk, Magdalena; Sokal, Jan; Andrzejewska, Ewa; Przewratil, Przemysław

    2015-01-01

    In the process of diagnosis and treatment of fractures, an X-ray study is typically performed. In modern medicine very important is the development of new diagnostic methods without adverse effects on the body. One of such techniques is ultrasound imaging. It has a high value in imaging most areas of the body, including the musculoskeletal system. Reports on the use of ultrasound in the evaluation of the callus are rare and this could be a method equivalent to or even better than standard radiographs. The aim of the study was to analyze the correlation of ultrasound with radiographs in imaging of callus formation after fractures of long bones in children and to analyze the correlation of vascular resistance index (RI) and the degree of vascularization of the callus with a subjective radiological assessment of the bone union quality. The prospective study was planned to qualify 50 children treated for long bones fractures of the arm, forearm, thigh and lower leg. Ultrasound diagnosis was carried out using a Philips iU22 camera equipped with a linear probe with 17-5-MHz resolution and MSK Superficial program. During ultrasound examination measurements of the callus were performed. Using the Power Doppler callus vascularity was visualized and vascular resistance index (RI) was measured. The same measurements were made within the corresponding area of the healthy limb. The results obtained by ultrasound were compared with radiograph measurements and with the subjective assessment of the callus quality. Preliminary results were developed on a group of 24 patients, where 28 fractured bones and 28 corresponding healthy bones were examined. Fifteen boys and 9 girls participated in the study. The average age at injury was, respectively, 11 and 9 years. In both groups fractures without displacement were the most frequent. A similar frequency was observed in fractures requiring reposition and subperiosteal fractures. In contrast, fractures with a slight displacement of the fragments, were 3 times more common in girls. Statistical analysis of the measurements of length and width of the callus demonstrated that the differences between results obtained in the ultrasound in comparison with X-rays were not statistically significant. Moreover, preliminary results showed a significantly higher degree of vascularization of the callus than of the healthy periosteum. Preliminary results indicate the high efficacy of ultrasound in the evaluation of callus formation after fractures of long bones in children and the possibility of its alternative use to X-ray examinations.

  14. System and method for improving ultrasound image acquisition and replication for repeatable measurements of vascular structures

    NASA Technical Reports Server (NTRS)

    Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)

    2006-01-01

    High resolution B-mode ultrasound images of the common carotid artery are obtained with an ultrasound transducer using a standardized methodology. Subjects are supine with the head counter-rotated 45 degrees using a head pillow. The jugular vein and carotid artery are located and positioned in a vertical stacked orientation. The transducer is rotated 90 degrees around the centerline of the transverse image of the stacked structure to obtain a longitudinal image while maintaining the vessels in a stacked position. A computerized methodology assists operators to accurately replicate images obtained over several spaced-apart examinations. The methodology utilizes a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time live ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, measurement of vascular dimensions such as carotid arterial IMT and diameter, the coefficient of variation is substantially reduced to values approximating from about 1.0% to about 1.25%. All images contain anatomical landmarks for reproducing probe angulation, including visualization of the carotid bulb, stacking of the jugular vein above the carotid artery, and initial instrumentation settings, used at a baseline measurement are maintained during all follow-up examinations.

  15. Evaluation of a Novel Wireless Transmission System for Trauma Ultrasound Examinations From Moving Ambulances.

    PubMed

    Morchel, Herman; Ogedegbe, Chinwe; Chaplin, William; Cheney, Brianna; Zakharchenko, Svetlana; Misch, David; Schwartz, Matthew; Feldman, Joseph; Kaul, Sanjeev

    2018-03-01

    To determine if physicians trained in ultrasound interpretation perceive a difference in image quality and usefulness between Extended Focused Assessment with Sonography ultrasound examinations performed at bedside in a hospital vs. by emergency medical technicians minimally trained in medical ultrasound on a moving ambulance and transmitted to the hospital via a novel wireless system. In particular, we sought to demonstrate that useful images could be obtained from patients in less than optimal imaging conditions; that is, while they were in transport. Emergency medical technicians performed the examinations during transport of blunt trauma patients. Upon patient arrival at the hospital, a bedside Extended Focused Assessment with Sonography examination was performed by a physician. Both examinations were recorded and later reviewed by physicians trained in ultrasound interpretation. Data were collected on 20 blunt trauma patients over a period of 13 mo. Twenty ultrasound-trained physicians blindly compared transmitted vs. bedside images using 11 Questionnaire for User Interaction Satisfaction scales. Four paired samples t-tests were conducted to assess mean differences between ratings for ambulatory and base images. Although there is a slight tendency for the average rating across all subjects and raters to be slightly higher in the base than in the ambulatory condition, none of these differences are statistically significant. These results suggest that the quality of the ambulatory images was viewed as essentially as good as the quality of the base images.

  16. IOTA Simple Rules in Differentiating between Benign and Malignant Adnexal Masses by Non-expert Examiners.

    PubMed

    Tinnangwattana, Dangcheewan; Vichak-Ururote, Linlada; Tontivuthikul, Paponrad; Charoenratana, Cholaros; Lerthiranwong, Thitikarn; Tongsong, Theera

    2015-01-01

    To evaluate the diagnostic performance of IOTA simple rules in predicting malignant adnexal tumors by non-expert examiners. Five obstetric/gynecologic residents, who had never performed gynecologic ultrasound examination by themselves before, were trained for IOTA simple rules by an experienced examiner. One trained resident performed ultrasound examinations including IOTA simple rules on 100 women, who were scheduled for surgery due to ovarian masses, within 24 hours of surgery. The gold standard diagnosis was based on pathological or operative findings. The five-trained residents performed IOTA simple rules on 30 patients for evaluation of inter-observer variability. A total of 100 patients underwent ultrasound examination for the IOTA simple rules. Of them, IOTA simple rules could be applied in 94 (94%) masses including 71 (71.0%) benign masses and 29 (29.0%) malignant masses. The diagnostic performance of IOTA simple rules showed sensitivity of 89.3% (95%CI, 77.8%; 100.7%), specificity 83.3% (95%CI, 74.3%; 92.3%). Inter-observer variability was analyzed using Cohen's kappa coefficient. Kappa indices of the four pairs of raters are 0.713-0.884 (0.722, 0.827, 0.713, and 0.884). IOTA simple rules have high diagnostic performance in discriminating adnexal masses even when are applied by non-expert sonographers, though a training course may be required. Nevertheless, they should be further tested by a greater number of general practitioners before widely use.

  17. Hemostatic Effects of Microbubble-Enhanced Low-Intensity Ultrasound in a Liver Avulsion Injury Model

    PubMed Central

    Feng, Guiying; Liu, Jianhua; Zhao, Xiaochen; Wei, Jinglu; Ou, Wencai; Xiao, Shuyi; Hu, Zhiwen; Wei, Hongqin; Liu, Zheng

    2014-01-01

    Objectives Microbubble-enhanced therapeutic ultrasound (MEUS) can block the blood flow in the organs. The aim of this study was to evaluate the hemostatic effect of microbubble-enhanced pulsed, low-intensity ultrasound in a New Zealand White rabbit model of avulsion trauma of the liver. The therapeutic ultrasound (TUS) transducer was operated with the frequency of 1.2 MHz and an acoustic pressure of 3.4 MPa. Microbubble-(MB) enhanced ultrasound (MEUS) (n = 6) was delivered to the distal part of the liver where the avulsion was created. Livers were treated by TUS only (n = 4) or MB only (n = 4) which served as controls. Bleeding rates were measured and contrast enhanced ultrasound (CEUS) was performed to assess the hemostatic effect, and liver hemoperfusion before and after treatment. Generally, bleeding rates decreased more than 10-fold after the treatment with MEUS compared with those of the control group (P<0.05). CEUS showed significant declines in perfusion. The peak intensity value and the area under the curve also decreased after insonation compared with those of the control group (P<0.05). Histological examination showed cloudy and swollen hepatocytes, dilated hepatic sinusoids, perisinusoidal spaces with erythrocyte accumulation in small blood vessels, obvious hemorrhage around portal areas and scattered necrosis in liver tissues within the insonation area of MEUS Group. In addition, necrosis was found in liver tissue 48 h after insonation. We conclude that MEUS might provide an effective hemostatic therapy for serious organ trauma such as liver avulsion injury. PMID:24788757

  18. Standard plane localization in ultrasound by radial component model and selective search.

    PubMed

    Ni, Dong; Yang, Xin; Chen, Xin; Chin, Chien-Ting; Chen, Siping; Heng, Pheng Ann; Li, Shengli; Qin, Jing; Wang, Tianfu

    2014-11-01

    Acquisition of the standard plane is crucial for medical ultrasound diagnosis. However, this process requires substantial experience and a thorough knowledge of human anatomy. Therefore it is very challenging for novices and even time consuming for experienced examiners. We proposed a hierarchical, supervised learning framework for automatically detecting the standard plane from consecutive 2-D ultrasound images. We tested this technique by developing a system that localizes the fetal abdominal standard plane from ultrasound video by detecting three key anatomical structures: the stomach bubble, umbilical vein and spine. We first proposed a novel radial component-based model to describe the geometric constraints of these key anatomical structures. We then introduced a novel selective search method which exploits the vessel probability algorithm to produce probable locations for the spine and umbilical vein. Next, using component classifiers trained by random forests, we detected the key anatomical structures at their probable locations within the regions constrained by the radial component-based model. Finally, a second-level classifier combined the results from the component detection to identify an ultrasound image as either a "fetal abdominal standard plane" or a "non- fetal abdominal standard plane." Experimental results on 223 fetal abdomen videos showed that the detection accuracy of our method was as high as 85.6% and significantly outperformed both the full abdomen and the separate anatomy detection methods without geometric constraints. The experimental results demonstrated that our system shows great promise for application to clinical practice. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Role of intraoperative ultrasound in achieving complete resection of intra-axial solid brain tumours.

    PubMed

    Mari, Abdul Razaque; Shah, Irfanullah; Imran, Muhammed; Ashraf, Junaid

    2014-12-01

    To determine the frequency of completeness of resection for intra-axial solid brain tumours with the help of intra-operative ultrasound to detect residual brain tumour. The cross-sectional study was conducted at the Department of Neurosurgery, Dow University of Health Sciences and Civil Hospital Karachi, from September 2009 to June 2010 and comprised patients with intra-axial solid brain lesion. During operation following standard craniotomy, multi-plane sonographic examination was performed using intra-operative ultrasound for tumour localisation and calculation of dimension, followed by tumour resection in the standard fashion. At the end of tumour resection ultrasound was again used for the detection of any residual tumour. Results of intra-operative ultrasound were compared with post-operative contrast magnetic resonance imaging. Of the 39 cases in which intra-operative ultrasound was performed, 32(82.1%) were males and 7(17.9%) were females, with an overall mean age of 42.6±19.7 years. Intra-operative ultrasonography was able to localise and delineate the tumour in all 39 (100%) cases. It showed no residual tumour in 36 (92.3%) cases, but in 3(7.7%) cases residual tumour was detected. Post-operative contrast enhancing magnetic resonance imaging showed no residual tumour in 35(89.7%) cases and in 4(10.3%) cases residual tumour was detected. The frequency of completely resected intra-axial solid brain tumour was 35(89.7%), while in 4(10.3%) cases incomplete resection was observed. The study concluded that intra-operative ultrasonography has an important role in achieving increased frequency of completely resected intra-axial solid brain tumours.

  20. Ultrasound predictors of neonatal outcome in intrauterine growth restriction.

    PubMed

    Craigo, S D; Beach, M L; Harvey-Wilkes, K B; D'Alton, M E

    1996-11-01

    Our purpose was to assess the value of commonly performed ultrasound parameters in predicting neonatal outcome of fetuses with intrauterine growth restriction (IUGR). One hundred twenty-seven patients were identified on ultrasound examination to have IUGR. Estimated weight percentile, amniotic fluid volume, umbilical artery Doppler velocimetry, and head circumference/abdominal circumference ratio were compared with neonatal outcome. Thirty infants had severely adverse courses. The degree of growth restriction was strongly associated with adverse outcome and neonatal death. Umbilical artery Doppler waveforms with absent or reverse end-diastolic flow were predicted of neonatal death, bronchopulmonary dysplasia (BPD), necrotizing enterocolitis (NEC), and adverse outcome in general. Oligohydramnios was predictive of adverse outcome and neonatal death. Logistic regression also showed that absent or reverse end-diastolic flow and oligohydramnios were independent predictors of adverse outcome. Ultrasound findings of low estimated weight percentile, absent or reverse end-diastolic umbilical blood flow, and oligohydramnios are independent predictors of adverse neonatal outcome of growth restricted fetuses.

  1. Feasibility of dynamic cardiac ultrasound transmission via mobile phone for basic emergency teleconsultation.

    PubMed

    Lim, Tae Ho; Choi, Hyuk Joong; Kang, Bo Seung

    2010-01-01

    We assessed the feasibility of using a camcorder mobile phone for teleconsulting about cardiac echocardiography. The diagnostic performance of evaluating left ventricle (LV) systolic function was measured by three emergency medicine physicians. A total of 138 short echocardiography video sequences (from 70 subjects) was selected from previous emergency room ultrasound examinations. The measurement of LV ejection fraction based on the transmitted video displayed on a mobile phone was compared with the original video displayed on the LCD monitor of the ultrasound machine. The image quality was evaluated using the double stimulation impairment scale (DSIS). All observers showed high sensitivity. There was an improvement in specificity with the observer's increasing experience of cardiac ultrasound. Although the image quality of video on the mobile phone was lower than that of the original, a receiver operating characteristic (ROC) analysis indicated that there was no significant difference in diagnostic performance. Immediate basic teleconsulting of echocardiography movies is possible using current commercially-available mobile phone systems.

  2. Ultrasound Metrology in Mexico: a round robin test for medical diagnostics

    NASA Astrophysics Data System (ADS)

    Amezola Luna, R.; López Sánchez, A. L.; Elías Juárez, A. A.

    2011-02-01

    This paper presents preliminary statistical results from an on-going imaging medical ultrasound study, of particular relevance for gynecology and obstetrics areas. Its scope is twofold, firstly to compile the medical ultrasound infrastructure available in cities of Queretaro-Mexico, and second to promote the use of traceable measurement standards as a key aspect to assure quality of ultrasound examinations performed by medical specialists. The experimental methodology is based on a round robin test using an ultrasound phantom for medical imaging. The physician, using its own ultrasound machine, couplant and facilities, measures the size and depth of a set of pre-defined reflecting and absorbing targets of the reference phantom, which simulate human illnesses. Measurements performed give the medical specialist an objective feedback regarding some performance characteristics of their ultrasound examination systems, such as measurement system accuracy, dead zone, axial resolution, depth of penetration and anechoic targets detection. By the end of March 2010, 66 entities with medical ultrasound facilities, from both public and private institutions, have performed measurements. A network of medical ultrasound calibration laboratories in Mexico, with traceability to The International System of Units via national measurement standards, may indeed contribute to reduce measurement deviations and thus attain better diagnostics.

  3. Implementation of a 4-Year Point-of-Care Ultrasound Curriculum in a Liaison Committee on Medical Education-Accredited US Medical School.

    PubMed

    Wilson, Sean P; Mefford, Jason M; Lahham, Shadi; Lotfipour, Shahram; Subeh, Mohammad; Maldonado, Gracie; Spann, Sophie; Fox, John C

    2017-02-01

    The established benefits of point-of-care ultrasound have given rise to multiple new and innovative curriculums to incorporate ultrasound teaching into medical education. This study sought to measure the educational success of a comprehensive and integrated 4-year point-of-care ultrasound curriculum. We integrated a curriculum consisting of traditional didactics combined with asynchronous learning modules and hands-on practice on live models with skilled sonographers into all 4 years of education at a Liaison Committee on Medical Education-accredited US Medical School. Each graduating student was administered an exit examination with 48 questions that corresponded to ultrasound milestones. Ninety-five percent (n = 84) of fourth-year medical students completed the exit examination. The mean score was 79.5% (SD, 10.2%), with mean scores on the ultrasound physics and anatomy subsections being 77.1% (SD, 11.0%) and 85.9% (SD, 21.0%), respectively. A comprehensive 4-year point-of-care ultrasound curriculum integrated into medical school may successfully equip graduating medical students with a fundamental understanding of ultrasound physics, anatomy, and disease recognition. © 2016 by the American Institute of Ultrasound in Medicine.

  4. [The effect of focused ultrasound on the physicochemical properties of Sarcoma 180 cell membrane].

    PubMed

    Li, Tao; Hao, Qiao; Wang, Xiaobing; Liu, Quanhong

    2009-10-01

    This study was amied to detect the changes in the cell membrane of Sarcoma 180 (S180) cells induced by focused ultrasound and to probe the underlying mechanism. The viability of tumor cells was examined at various intensities and different treatment times by ultrasound at the frequency of 2.2MHz. Flow cytometry and fluorescence microscopy were used to detect the loading of fluorescein isothiocyanate dextran (FD500) which signifies the change of membrane permeability. The results showed that after the cells were treated by ultrasound, especially when irradiated for 60s, the number of fluorescent cell, which represented the transient change of membrane permeabilization with cell survival, increased significantly. Then the damage of cell membrane was evaluated by the measurement of lactate dehydrogenase (LDH) release which became more severe as the radiation time was increasing. The generation of lipid peroxidation was estimated using the Thibabituric Acid (TBA) method after irradiation. The results reveal that the instant cell damage effects induced by ultrasound may be related to the improved membrane lipid peroxidation levels post-treatment. The physicochemical properties of S180 cell membrane were changed by focused ultrasound. The findings also imply an exposure time-dependent pattern and suggest that the lipid peroxidation produced by acoustic cavitation may play important roles in these actions.

  5. [Ultrasound diagnosis of aneurysm of the vein of Galen in children].

    PubMed

    Gazikalović, S; Kosutić, J; Komar, P; Vukomanović, V; Mogić, M

    2001-01-01

    Aneurysm of the vein of Galen is rare and complex vascular disorder that develops during embriogenesis and provokes significant haemodynamic changes. Boys are more frequently involved. During the foetal period Ballantyne syndrome may develop, and postnatal clinical presentation vary with ages. Serious haemodynamic changes are followed by congestive heart failure and, if not treated, with lethal exitus. Fast and correct diagnosis is very important. Ultrasound examination of central nervous system supported with Duplex-Doppler and Colour-Doppler examination of the head and heart enables the diagnosis. This text comments ultrasound presentation of the malformation and ultrasound diagnostic possibilities.

  6. Value of stress ultrasound for the diagnosis of chronic ankle instability compared to manual anterior drawer test, stress radiography, magnetic resonance imaging, and arthroscopy.

    PubMed

    Cho, Jae Ho; Lee, Doo Hyung; Song, Hyung Keun; Bang, Joon Young; Lee, Kyung Tai; Park, Young Uk

    2016-04-01

    Clinicians frequently diagnose chronic ankle instability using the manual anterior drawer test and stress radiography. However, both examinations can yield incorrect results and do not reveal the extent of ankle instability. Stress ultrasound has been reported to be a new diagnostic tool for the diagnosis of chronic ankle instability. The purpose of this study was to assess the diagnostic value of stress ultrasound for chronic ankle instability compared to the manual anterior drawer test, stress radiography, magnetic resonance imaging (MRI), and arthroscopy. Twenty-eight consecutive patients who underwent ankle arthroscopy and subsequent modified Broström repair for treatment of chronic ankle instability were included. The arthroscopic findings were used as the reference standard. A standardized physical examination (manual anterior drawer test), stress radiography, MRI, and stress ultrasound were performed to assess the anterior talofibular ligament (ATFL) prior to operation. Ultrasound images were taken in the resting position and the maximal anterior drawer position. Grade 3 lateral instability was verified arthroscopically in all 28 cases with a clinical diagnosis (100%). Twenty-two cases showed grade III instability on the manual anterior drawer test (78.6%). Twenty-four cases displayed anterior translation exceeding 5 mm on stress radiography (86%), and talar tilt angle exceeded 15° in three cases (11 %). Nineteen cases displayed a partial chronic tear (change in thickness or signal intensity), and nine cases displayed complete tear on MRI (100%). Lax and wavy ATFL was evident on stress ultrasound in all cases (100 %). The mean value of the ATFL length was 2.8 ± 0.3 cm for the stressed condition and 2.1 ± 0.2 cm for the resting condition (p < 0.001). Stress ultrasound may be useful for the diagnosis of chronic ankle instability in addition to the manual anterior drawer test and stress radiography. III.

  7. How is shoulder ultrasound done in Italy? A survey of clinical practice.

    PubMed

    Zappia, Marcello; Aliprandi, Alberto; Pozza, Simona; Doniselli, Fabio Martino; Gitto, Salvatore; Sconfienza, Luca Maria

    2016-12-01

    To define when an ultrasound examination of the shoulder can be considered complete and how many examinations currently performed in Italy are actually complete according to that definition. Reports and images of previously performed ultrasound examinations of the shoulder of patients seen in 2014 for interventional procedures were reviewed for the following items, according to guidelines published by the European Society of Musculoskeletal Radiology: long biceps, subscapularis, supraspinatus, external rotators, acromioclavicular joint, subacromial bursa, subacromial space, coraco-acromial ligament, and the posterior recess. The first six items were considered mandatory in a complete shoulder ultrasound examination. The specialization of the performing physician was noted. The number of complete examinations performed by different physicians was compared with the number of incomplete examinations. We analyzed 324 examinations (212 women, 112 men; mean age = 47 ± 12 years). The most frequently reported item was the supraspinatus tendon (83 %), the least frequently reported was the posterior recess (3 %). The image that was most frequently found was the long head of the biceps tendon (77 %), the least frequently found was the coraco-acromial ligament (3 %). The median number of images/examination was 6 (25th-75th percentiles, range 4-9). The mean number of unrecognizable images was 3 (2-4). A radiologist performed the examination in 269 patients (83 %). The rate of complete examinations was 47 %. The number of complete examinations performed by physicians from different specialties was not significantly different from that of incomplete examinations (P = 0.228). Complete shoulder ultrasound examinations account for less than 50 % of those performed in clinical practice in some Italian regions. Standardized scanning protocols and structured reporting may help to improve this figure and consistency among providers performing these examinations.

  8. Endoscopic ultrasound for the characterization and staging of rectal cancer. Current state of the method. Technological advances and perspectives.

    PubMed

    Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M

    2015-06-01

    Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.

  9. Comparison of gestational age at birth based on last menstrual period and ultrasound during the first trimester.

    PubMed

    Hoffman, Caroline S; Messer, Lynne C; Mendola, Pauline; Savitz, David A; Herring, Amy H; Hartmann, Katherine E

    2008-11-01

    Reported last menstrual period (LMP) is commonly used to estimate gestational age (GA) but may be unreliable. Ultrasound in the first trimester is generally considered a highly accurate method of pregnancy dating. The authors compared first trimester report of LMP and first trimester ultrasound for estimating GA at birth and examined whether disagreement between estimates varied by maternal and infant characteristics. Analyses included 1867 singleton livebirths to women enrolled in a prospective pregnancy cohort. The authors computed the difference between LMP and ultrasound GA estimates (GA difference) and examined the proportion of births within categories of GA difference stratified by maternal and infant characteristics. The proportion of births classified as preterm, term and post-term by pregnancy dating methods was also examined. LMP-based estimates were 0.8 days (standard deviation = 8.0, median = 0) longer on average than ultrasound estimates. LMP classified more births as post-term than ultrasound (4.0% vs. 0.7%). GA difference was greater among young women, non-Hispanic Black and Hispanic women, women of non-optimal body weight and mothers of low-birthweight infants. Results indicate first trimester report of LMP reasonably approximates gestational age obtained from first trimester ultrasound, but the degree of discrepancy between estimates varies by important maternal characteristics.

  10. Ultrasound Fracture Diagnosis in Space

    NASA Technical Reports Server (NTRS)

    Dulchavsky, Scott A.; Amponsah, David; Sargsyan, Ashot E.; Garcia, Kathleen M.; Hamilton, Douglas R.; vanHolsbeeck, Marnix

    2010-01-01

    Introduction: This ground-based investigation accumulated high-level clinical evidence on the sensitivity and specificity of point of care ultrasound performed by expert and novice users for the rapid diagnosis of musculoskeletal (MSK) injuries. We developed preliminary educational methodologies to provide just-in-time training of novice users by creating multi-media training tools and imaging procedures for non expert operators and evaluated the sensitivity and specificity of non-expert performed musculoskeletal ultrasound to diagnose acute injuries in a Level 1 Trauma Center. Methods: Patients with potential MSK injuries were identified in the emergency room. A focused MSK ultrasound was performed by expert operators and compared to standard radiographs. A repeat examination was performed by non-expert operators who received a short, just-in-time multimedia education aid. The sensitivity and specificity of the expert and novice ultrasound examinations were compared to gold standard radiography. Results: Over 800 patients were enrolled in this study. The sensitivity and specificity of expert performed ultrasound exceeded 98% for MSK injuries. Novice operators achieved 97% sensitivity and 99% specificity for targeted examinations with the greatest error in fractures involving the hand and foot. Conclusion: Point of care ultrasound is a sensitive and specific diagnostic test for MSK injury when performed by experts and just-in-time trained novice operators.

  11. Sports Ultrasound: Applications Beyond the Musculoskeletal System.

    PubMed

    Finnoff, Jonathan T; Ray, Jeremiah; Corrado, Gianmichael; Kerkhof, Deanna; Hill, John

    2016-09-01

    Traditionally, ultrasound has been used to evaluate musculoskeletal injuries in athletes; however, ultrasound applications extend well beyond musculoskeletal conditions, many of which are pertinent to athletes. Articles were identified in PubMed using the search terms ultrasound, echocardiogram, preparticipation physical examination, glycogen, focused assessment with sonography of trauma, optic nerve, and vocal cord dysfunction. No date restrictions were placed on the literature search. Clinical review. Level 4. Several potential applications of nonmusculoskeletal ultrasound in sports medicine are presented, including extended Focused Assessment with Sonography for Trauma (eFAST), limited echocardiographic screening during preparticipation physical examinations, assessment of muscle glycogen stores, optic nerve sheath diameter measurements in athletes with increased intracranial pressure, and assessment of vocal cord dysfunction in athletes. Ultrasound can potentially be used to assist athletes with monitoring their muscle glycogen stores and the diagnosis of multiple nonmusculoskeletal conditions within sports medicine. © 2016 The Author(s).

  12. Investigation of the acute plantar fasciitis with contrast-enhanced ultrasound and shear wave elastography - first results.

    PubMed

    Putz, Franz Josef; Hautmann, Matthias G; Banas, Miriam C; Jung, Ernst Michael

    2017-01-01

    The plantar fasciitis is a common disease with a high prevalence in public and a frequent cause of heel pain. In our pilot study, we wanted to characterise the feasibility of shear-wave elastography and contrast-enhanced ultrasound (CEUS) in the assessment of the plantar fasciitis. 23 cases of painful heels were examined by B-Mode ultrasound, Power Doppler (PD), shear wave elastography and contrast-enhanced ultrasound before anti-inflammatory radiation. Time-intensity-curves were analysed by the integrated software. The results for area-under-the-curve (AUC), peak, time-to-peak (TTP) and mean-transit-time (MTT) were compared between the plantar fascia and the surrounding tissue. All cases showed thickening of the plantar fascia, in most cases with interstitial oedema (87.0%). Shear wave elastography showed inhomogeneous stiffness of the plantar fascia. 83.3% of cases showed a visible hyperperfusion in CEUS at the proximal plantar fascia in comparison to the surrounding tissue. This hyperperfusion could also be found in 75.0% of cases with no signs of vascularisation in PD. AUC (p = 0.0005) and peak (p = 0.037) were significantely higher in the plantar fascia than in the surrounding tissue. CEUS and shear wave elastography are new diagnostic tools in the assessment of plantar fasciitis and can provide quantitative parameters for monitoring therapy.

  13. Evaluation of a Short-term Training Program in Bedside Emergency Ultrasound in Southwestern Tanzania.

    PubMed

    Shaffer, Mark; Brown, Heather A; McCoy, Chloé; Bashaka, Prosper

    2017-03-01

    To evaluate the effect of a short-term training program in emergency ultrasound on physician skills and attitudes in southwestern Tanzania. Eight registrar physicians at Mbeya Zonal Referral Hospital (Mbeya, Tanzania) underwent a 5-day course in bedside emergency ultrasound, focusing primarily on the focused assessment with sonography for trauma examination, including didactic sessions, practical sessions, and on-job training. The impact on ultrasound knowledge was assessed by pretest and posttest evaluations. Provider skill was evaluated by a standardized observed simulated patient encounter. Attitudes toward ultrasound training, utility, and self-confidence were assessed by a post-training questionnaire. All 8 physicians who began the training completed the course and successfully passed their objective structured clinical examination. There was a statistically significant improvement in written ultrasound test scores from 31% to 66% (P < .01) after the course. Most trainees felt confident performing and interpreting a basic focused assessment with sonography for trauma examination at the end of the course, and 7 of 8 stated that they would consider paying tuition for similar courses in the future. Main concerns with the course revolved around insufficient time dedicated to practicing under supervision. Registrar physicians in Tanzania can effectively learn basic emergency ultrasound skills in a short-term training program. Similar future programs may consider heavier emphasis on practical hands-on training with experts. Ongoing data collection is required to understand the true impact of such training on long-term ultrasound use and patient outcomes. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Feasibility and reliability of pocket-size ultrasound examinations of the pleural cavities and vena cava inferior performed by nurses in an outpatient heart failure clinic.

    PubMed

    Dalen, Havard; Gundersen, Guri H; Skjetne, Kyrre; Haug, Hilde H; Kleinau, Jens O; Norekval, Tone M; Graven, Torbjorn

    2015-08-01

    Routine assessment of volume state by ultrasound may improve follow-up of heart failure patients. We aimed to study the feasibility and reliability of focused pocket-size ultrasound examinations of the pleural cavities and the inferior vena cava performed by nurses to assess volume state at an outpatient heart failure clinic. Ultrasound examinations were performed in 62 included heart failure patients by specialized nurses with a pocket-size imaging device (PSID). Patients were then re-examined by a cardiologist with a high-end scanner for reference within 1 h. Specialized nurses were able to obtain and interpret images from both pleural cavities and the inferior vena cava and estimate the volume status in all patients. Time consumption for focused ultrasound examination was median 5 min. In total 26 patients had any kind of pleural effusion (in 39 pleural cavities) by reference. The sensitivity, specificity, positive and negative predictive values were high, all ≥ 92%. The correlations with reference were high for all measurements, all r ≥ 0.79. Coefficients of variation for end-expiratory dimension of inferior vena cava and quantification of pleural effusion were 10.8% and 12.7%, respectively. Specialized nurses were, after a dedicated training protocol, able to obtain reliable recordings of both pleural cavities and the inferior vena cava by PSID and interpret the images in a reliable way. Implementing focused ultrasound examinations to assess volume status by nurses in an outpatient heart failure clinic may improve diagnostics, and thus improve therapy. © The European Society of Cardiology 2014.

  15. [An attempt to use ultrasonic technique for confirming the diagnosis, planning and observation of long-term treatment results of painful temporo-mandibular joint dysfunction].

    PubMed

    Ey-Chmielewska, H

    1998-01-01

    The author presents an attempt of using ultrasonographic technique in diagnosis, planning and observation of treatment results of temporo-mandibular joint pain dysfunctions. Temporo-mandibular joint pain dysfunctions are interchangeably also called temporo-mandibular joint functional disorders. The assessment of pain symptoms in temporo-mandibular joint dysfunctions pain symptoms is principally based on a subjective estimation by the examining practitioner. There is no univocal definition of the disease or a simple index evidencing important symptoms in decision making. Additionally X-ray technique examinations, being hitherto used, in early stages of the disorder do not allow to diagnose it, and are also burdensome to a patient. The aim of this study was to confirm visibility of anatomical elements of the temporo-mandibular joint in an ultrasound examination, assess the mobility of the articular disc before, during and after prosthetic treatment with and without the use of ultrasound technique, and to determine the period of time necessary to obtain a therapeutic effect. The study material consisted of 180 patients, 128 women and 52 men, aged 20 to 60 years, treated by applying prostheses because of temporo-mandibular joint pain dysfunction, in the Department of Prosthetic Dentistry of the Pomeranian Medical Academy. The patients were divided into 2 groups, control and study group. The control group consisted of 90 patients, 63 women and 27 men. In this group prosthetic treatment planning and observation of results was based on a subjective estimation of the practitioner. The study group here comprised 90 patients, 65 women and 25 men, aged 26 to 60 years. In this group prosthetic treatment planning and observation of treatment results were carried on with the use of ultrasound technique. Data from both groups concerning history, results of examinations carried out by ultrasound technique, and the assessment of ultrasound examination were noted on standard examination records used in the Department of Prosthetic Dentistry. For the need of this study an own ultrasound technique was elaborated which allowed for analyzing the ultrasound image in a static situation and during functioning. The ultrasound examination was accomplished with the use of Acuson 128 XP apparatus, linear probe 7.5 MHz. In both groups prosthetic treatment was carried out using different prosthetic methods such as: splints, occlusal adjustment on fixed prosthetic restorations in therapeutical occulus et height in abnormal occlusion. In the study group the therapeutical occulus height was determined under the control of ultrasound technique. Statistical analysis of the obtained results was performed with the use of chi-square test and chi-square test with Yates correction. On the basis of the accomplished study it has been determined that the ultrasound technique makes it possible to visualize morphological elements and facilitates functional observation of the temporo-mandibular joint, articular disc, mandibular condyle and lateral pterygoid muscle in a degree which allows for planning the treatment and the observation of results (Tab. 1-6). The use of ultrasound technique in determining spatial position of the mandible in temporo-mandibular joint permitted to objectively estimate examination results in the study group. A small number of publications on the use of ultrasound technique in functional examination of the temporo-mandibular joint accessible in foreign literature and general reference on the subject in Polish literature do not allow for an objective comparison of obtained study results.

  16. [Apple-Macintosh compatible software for documentation, management and evaluation of ultrasound findings in obstetrics].

    PubMed

    Kurmanavicius, J; Huch, R; Huch, A

    1993-02-01

    The advantage of using a computer to automate routine calculations and print out charts of the obstetrical ultrasound examination is obvious. This report describes a software designed to simplify the documentation and analysis of ultrasound data in obstetrics. The system is easy to use, even for persons with little computer knowledge. The programme was written in FoxBase+/Mac (Fox Software, Inc., USA). FoxBase+/Mac takes full advantage of the easy-to-learn, easy-to-use Macintosh interface and is also very fast. Another advantage of this software is that it can be used in teaching. Non-experienced examinators can double-check the correctness of their scanning planes by observing the ultrasound pictures with the markers indicating the right measurement sites and the lists of standard values of biometrical parameters for the corresponding gestational age on the screen. In routine obstetrical ultrasound examinations it takes less than 5 min to enter the foetal biometry data and print out reports. These reports are informative and easy to interpret.

  17. Hyperechogenicity during high intensity focused ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Crum, Lawrence; Bailey, Michael; Rabkin, Brian; Khokhlova, Vera; Vaezy, Shahram

    2005-09-01

    Ultrasound guidance of HIFU therapy is attractive because of its portability, low cost, real-time image processing, simple integration with HIFU instruments, and the extensive availability of diagnostic ultrasound; however, the use of ultrasound visualization for the guidance and monitoring of HIFU therapy often relies on the appearance of a hyperechoic region in the ultrasound image. It is often assumed that the formation of a hyperechoic region at the HIFU treatment site results from bubble activity generated during HIFU exposure. However, it has been determined that this region can be generated with relatively short bursts of HIFU (on the order of 30 ms), bursts so short that negligible temperature elevations are expected to occur. In examining the histology associated with these hyperechoes, there is little evidence of traditional cavitation damage; rather, it appears as if there are many bubbles generated within the individuals cells, suggesting a thermal mechanism. Thermocouple measurements of the temperature elevation were inaccurate due to the short insonation period, but showed only a few-degree temperature rise. These anomalous results will be presented, along with additional data on HIFU hyperechogenicity, and a hypothesis given for the phenomenological origins of this effect. [Work supported in part by the NSBRI, U.S. Army, and the NIH.

  18. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance.

    PubMed

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index - 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic-therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations.

  19. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance

    PubMed Central

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index – 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic–therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations. PMID:25999768

  20. Frequency and number of ultrasound lung rockets (B-lines) using a regionally based lung ultrasound examination named vet BLUE (veterinary bedside lung ultrasound exam) in dogs with radiographically normal lung findings.

    PubMed

    Lisciandro, Gregory R; Fosgate, Geoffrey T; Fulton, Robert M

    2014-01-01

    Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions. © 2014 American College of Veterinary Radiology.

  1. [Carpal canal ultrasound examination in patients with mild hand-arm vibration disease].

    PubMed

    Liu, Y Z; Ye, Z H; Yang, W L; Zhu, J X; Lu, Q J; Su, W L

    2016-08-20

    Objective: To investigate the clinical value of ultrasound examination of carpal canal structure in patients with mild hand-arm vibration disease. Methods: A total of 29 patients (58 wrists) with mild hand-arm vibration disease who were treated in Shenzhen Prevention and Treatment Center for Occupational Diseases from May to December, 2015 were enrolled as observation group, and 20 healthy volunteers (40 wrists) were enrolled as the control group. Color Doppler ultrasound was used to observe the morphology and echo of the median nerve in the carpal canal and 9 muscle tendons and transverse carpal ligament. The thickness of transverse carpal ligament and diameter of the median nerve at the level of the hamulus of hamate bone were measured, as well as the cross-sectional area of the median nerve at the level of pisiform bone. Results: In the 29 patients with hand-arm vibration disease patients in the observation group, 8 experienced entrapment of the median nerve in the carpal canal, among whom 5 had entrapment in both wrists; there were 13 wrists (23%) with nerve entrapment and 45 wrists (77%) without nerve entrapment. Compared with the control group, the patients with hand-arm vibration disease and nerve entrapment in the observation group showed significant thickening of the transverse carpal ligament at the level of the hamulus of hamate bone and a significant increase in the cross-sectional area of the median nerve at the level of pisiform bone ( P <0.05) , while there were no significant differences in the thickness of transverse carpal ligament at the level of the hamulus of hamate bone and the cross-sectional area of the median nerve at the level of pisiform bone ( t=- 9.397 and -4.385, both P >0.05) . Conclusion: Ultrasound examination can clearly show the radiological changes of carpal canal contents in patients with mild hand-arm vibration disease and has a certain diagnostic value in nerve damage in patients with hand-arm vibration disease.

  2. Anterolateral ankle impingement: findings and diagnostic accuracy with ultrasound imaging.

    PubMed

    McCarthy, C L; Wilson, D J; Coltman, T P

    2008-03-01

    The objective was to evaluate the findings and diagnostic accuracy of ultrasound in antero-lateral ankle impingement (ALI) with clinical and arthroscopic correlation. Seventeen elite footballers with chronic ankle pain were referred for ultrasound with a clinical diagnosis of ALI (n = 8) or a control condition (n = 9; lateral mechanical instability, osteochondral defect, intra-articular bodies and osteoarthritis). Ultrasound examination included the antero-lateral gutter for abnormal synovial tissue (synovitic lesion), lateral ligament integrity, tibiotalar joint and osseous spurs of the distal tibia and talus. Ultrasound findings were correlated with subsequent arthroscopic appearance. Ultrasound examination detected a synovitic mass in the antero-lateral gutter in all 8 footballers with clinical ALI (100%) and in 2 patients with a control diagnosis (22%). Arthroscopic correlation of antero-lateral synovitis and fibrosis was present in all 10 cases (100%). The synovitic lesion was seen at ultrasound as a nodular soft tissue mass of mixed echogenicity within the antero-lateral gutter, which extruded anteriorly with manual compression of the distal fibula against the tibia. Increased blood supply was detected using power Doppler imaging in only 1 patient. The synovitic lesion measured >10 mm in its maximum dimension in 7 footballers with clinical ALI and <10 mm in the control group. Additional ultrasound findings in patients with abnormal antero-lateral synovial tissue included an anterior talofibular ligament injury in all patients (n = 10), a tibiotalar joint effusion (n = 6) and osseous spurs (n = 4). Antero-lateral synovitic tissue was accurately identified at ultrasound in the absence of an effusion (n = 4). No synovitic lesion was detected at ultrasound or arthroscopy in the remaining 7 patients with a control diagnosis. Ultrasound is accurate in detecting synovitic lesions within the antero-lateral gutter, demonstrating associated ligamentous injuries and in differentiating soft tissue from osseous impingement. Synovitic lesions in two control patients suggest that abnormal antero-lateral soft tissue does not necessarily imply the presence of symptomatic ALI. Synovitic lesions in excess of 10 mm were associated with symptoms. Ultrasound will not demonstrate osteocartilaginous lesions or stress fractures and may overlook some loose bodies. Ultrasound findings together with clinical correlation can be used to direct arthroscopic examination and surgical debridement.

  3. Standards of ultrasound imaging of the adrenal glands

    PubMed Central

    Jakubowski, Wiesław S.; Dobruch-Sobczak, Katarzyna; Kasperlik-Załuska, Anna A.

    2015-01-01

    Adrenal glands are paired endocrine glands located over the upper renal poles. Adrenal pathologies have various clinical presentations. They can coexist with the hyperfunction of individual cortical zones or the medulla, insufficiency of the adrenal cortex or retained normal hormonal function. The most common adrenal masses are tumors incidentally detected in imaging examinations (ultrasound, tomography, magnetic resonance imaging), referred to as incidentalomas. They include a range of histopathological entities but cortical adenomas without hormonal hyperfunction are the most common. Each abdominal ultrasound scan of a child or adult should include the assessment of the suprarenal areas. If a previously non-reported, incidental solid focal lesion exceeding 1 cm (incidentaloma) is detected in the suprarenal area, computed tomography or magnetic resonance imaging should be conducted to confirm its presence and for differentiation and the tumor functional status should be determined. Ultrasound imaging is also used to monitor adrenal incidentaloma that is not eligible for a surgery. The paper presents recommendations concerning the performance and assessment of ultrasound examinations of the adrenal glands and their pathological lesions. The article includes new ultrasound techniques, such as tissue harmonic imaging, spatial compound imaging, three-dimensional ultrasound, elastography, contrast-enhanced ultrasound and parametric imaging. The guidelines presented above are consistent with the recommendations of the Polish Ultrasound Society. PMID:26807295

  4. Relationship between severity of shoulder subluxation and soft-tissue injury in hemiplegic stroke patients.

    PubMed

    Huang, Shih-Wei; Liu, Sen-Yung; Tang, Hao-Wei; Wei, Ta-Sen; Wang, Wei-Te; Yang, Chao-Pin

    2012-09-01

    The aims of this study were: (i) to determine whether the severity of post-hemiplegic shoulder subluxation in stroke patients correlates with soft-tissue injury; and (ii) to determine the shoulder subluxation measurement cut-off points that are indications for further ultrasound examination for soft-tissue injuries in these patients. Cross-sectional study. A total of 39 stroke patients with shoulder subluxation. Shoulder subluxation was evaluated by physical examination, radiography and ultrasound. Soft-tissue injuries were assessed by ultrasound. Subluxation parameters were entered into stepwise logistic regression analyses to predict biceps and supraspinatus tendonitis. With the assumption that shoulder subluxation can be a predisposing factor for tendonitis, receiver operating characteristic curves for shoulder subluxation parameters of the affected side were used to determine cut-off points for optimal sensitivity and specificity of biceps and supraspinatus tendonitis. Shoulder subluxation lateral distance, measured by physical examination, is a predictor for supraspinatus tendonitis (odds ratio = 34.9, p = 0.036). Further ultrasound investigation for soft-tissue injury is indicated when subluxation lateral distance, measured by physical examination is ≥ 2.25 cm or, measured by radiographic examination, ≥ 3.18 cm for lateral distance, ≥ 3.08 cm for vertical distance, or ≥ 2.65 cm for horizontal distance. When post-hemiplegic shoulder subluxation measurements exceed the above-mentioned cut-off points in physical or radiographic examinations, further ultrasound evaluation for soft-tissue injury is recommended.

  5. Robot-based tele-echography: clinical evaluation of the TER system in abdominal aortic exploration.

    PubMed

    Martinelli, Thomas; Bosson, Jean-Luc; Bressollette, Luc; Pelissier, Franck; Boidard, Eric; Troccaz, Jocelyne; Cinquin, Philippe

    2007-11-01

    The TER system is a robot-based tele-echography system allowing remote ultrasound examination. The specialist moves a mock-up of the ultrasound probe at the master site, and the robot reproduces the movements of the real probe, which sends back ultrasound images and force feedback. This tool could be used to perform ultrasound examinations in small health care centers or from isolated sites. The objective of this study was to prove, under real conditions, the feasibility and reliability of the TER system in detecting abdominal aortic and iliac aneurysms. Fifty-eight patients were included in 2 centers in Brest and Grenoble, France. The remote examination was compared with the reference standard, the bedside examination, for aorta and iliac artery diameter measurement, detection and description of aneurysms, detection of atheromatosis, the duration of the examination, and acceptability. All aneurysms (8) were detected by both techniques as intramural thrombosis and extension to the iliac arteries. The interobserver correlation coefficient was 0.982 (P < .0001) for aortic diameters. The rate of concordance between 2 operators in evaluating atheromatosis was 84% +/- 11% (95% confidence interval). Our study on 58 patients suggests that the TER system could be a reliable, acceptable, and effective robot-based system for performing remote abdominal aortic ultrasound examinations. Research is continuing to improve the equipment for general abdominal use.

  6. High Resolution Anatomic and Elastographic Transrectal Ultrasound for Improved Diagnosis of Prostate Cancer

    DTIC Science & Technology

    2007-02-01

    Elastographic Transrectal Ultrasound for Improved Diagnosis of Prostate Cancer PRINCIPAL INVESTIGATOR: John A. Hossack, Ph.D...Resolution Anatomic and Elastographic Transrectal Ultrasound for Improved 5a. CONTRACT NUMBER Diagnosis of Prostate Cancer 5b. GRANT NUMBER...improve upon conventional Digital Rectal Examination (DRE) and PSA blood test by using ultrasound elasticity imaging. A latex sheath over the transrectal

  7. Sonographic Evaluation of Clinically Significant Perigraft Hematomas in Kidney Transplant Recipients.

    PubMed

    Fananapazir, Ghaneh; Rao, Rajiv; Corwin, Michael T; Naderi, Sima; Santhanakrishnan, Chandrasekar; Troppmann, Christoph

    2015-10-01

    The purpose of this study was to assess the sensitivity of ultrasound in evaluating peritransplant hematomas that require surgical evacuation in recipients of kidney transplants. Thirty-four patients who underwent 37 hematoma evacuations underwent ultrasound examinations in the 24 hours before surgical evacuation. The operative reports were evaluated for presence and size of collection, presence of active bleeding at operation, and composition of the hematoma. The clinical findings leading to the ultrasound examination were recorded. Ultrasound examinations were evaluated in consensus by two board-certified and fellowship-trained abdominal radiologists for the presence, size, and echogenicity of the collection; subjective perfusion visualized with color and power Doppler ultrasound; velocities of the renal arteries; and arcuate artery resistive indexes. Ten of the 37 imaged hematomas (27%) had either no or small (< 50 mL) fluid collections on ultrasound examination. With sonographic volumetry, the reported intraoperative volumes were underestimated by 46%. The mean arcuate artery resistive index was 0.82 in the superior pole, 0.81 in the mid pole, and 0.78 in the inferior pole of the kidney. A decrease in hemoglobin level was the most sensitive clinical finding for determining the presence of perigraft hematomas. Our results suggest that gray-scale sonography alone appears to have limited sensitivity in detecting clinically significant peritransplant hematomas and that its use may result in overall underestimates of hematomas.

  8. Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study

    PubMed Central

    Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard

    2016-01-01

    Objectives Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. Methods HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Results Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Conclusions Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. Trial registration number NCT01794715. PMID:26438785

  9. Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study.

    PubMed

    Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard

    2016-01-01

    Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. NCT01794715. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Measurement of tissue viscoelasticity with ultrasound

    NASA Astrophysics Data System (ADS)

    Greenleaf, J. F.; Alizad, A.

    2017-02-01

    Tissue properties such as elasticity and viscosity have been shown to be related to such tissue conditions as contraction, edema, fibrosis, and fat content among others. Magnetic Resonance Elastography has shown outstanding ability to measure the elasticity and in some cases the viscosity of tissues, especially in the liver, providing the ability to stage fibrotic liver disease similarly to biopsy. We discuss ultrasound methods of measuring elasticity and viscosity in tissues. Many of these methods are becoming widely available in the extant ultrasound machines distributed throughout the world. Some of the methods to be discussed are in the developmental stage. The advantages of the ultrasound methods are that the imaging instruments are widely available and that many of the viscoelastic measurements can be made during a short addition to the normal ultrasound examination time. In addition, the measurements can be made by ultrasound repetitively and quickly allowing evaluation of dynamic physiologic function in circumstances such as muscle contraction or artery relaxation. Measurement of viscoelastic tissue mechanical properties will become a consistent part of clinical ultrasound examinations in our opinion.

  11. Multiparametric ultrasonography and ultrasound elastography in the differentiation of parathyroid lesions from ectopic thyroid lesions or lymphadenopathies.

    PubMed

    Isidori, Andrea M; Cantisani, Vito; Giannetta, Elisa; Diacinti, Daniele; David, Emanuele; Forte, Valerio; Elia, Daniela; De Vito, Corrado; Sbardella, Emilia; Gianfrilli, Daniele; Monteleone, Francesco; Pepe, Jessica; Minisola, Salvatore; Ascenti, Giorgio; D'Andrea, Vito; Catalano, Carlo; D'Ambrosio, Ferdinando

    2017-08-01

    To evaluate the accuracy of ultrasound elastography with Elastoscan TM Core Index in the differential diagnosis of parathyroid lesions from ectopic thyroid nodules and lymph nodes. Seventy nine patients with repeatedly high levels of circulating intact parathyroid hormone, normal vitamin D and renal function tests, with an ultrasound scan showing a neck lesion, sharply demarcated from the thyroid lobules, were consecutively enrolled. Ultrasound with and without Color Doppler and ultrasound elastography were performed before histological examination. All ultrasound features, vascularization and ultrasound elastography diagnostic performance were assessed using ROC curves. Histological examination confirmed 47 parathyroid lesions, 18 thyroid ectopic nodules and 14 reactive lymph nodes. In distinguishing parathyroid from thyroid nodules, shape had a 100 % sensitivity (95 % CI 92.4-100) and 50 % specificity (95 % CI 37.2-64.7), cleavage had a 85.1 % sensitivity (95 % CI 72.3-92.6) and 77.8 % specificity (95 % CI 65.1-88) while peripheral vascularization had a sensitivity of 91.5 (95 % CI 79.6-97.6) and specificity of 72.2 (95 % CI 46.5-90.3). An Elastoscan TM Core Indexof 1.28 was 46 % sensitive (95 % CI 33.4-58.7) and 77 % specific (95 % CI 66.2-89.1) in discriminating parathyroid lesions from thyroid nodules. An Elastoscan TM Core Index of 1.0 was 78 % sensitive (95 % CI 65.1-88) and 71 % specific (95 % CI 56-81.3) in discriminating parathyroid lesions from lymph nodes (p = 0.045). An Elastoscan TM Core Index greater than 2.58 had a 100 % sensitivity (95 % CI 43.8-100) and 95.4 % specificity (95 % CI 38.3-99.7) in discriminating malignant from benign parathyroid nodules. Elastoscan TM Core Index was significantly higher in thyroid nodules than in reactive lymph nodes (1.18 ± 0.62, p = 0.008). The ultrasound features of cleavage and peripheral vascularization help to differentiate parathyroid from thyroid nodules. Elastoscan TM Core Index can improve ultrasound discrimination of parathyroid lesions from lymph nodes. The Elastoscan TM Core Index is significantly higher in malignant than in benign parathyroid lesions.

  12. Comparison of optical and power Doppler ultrasound imaging for non-invasive evaluation of arsenic trioxide as a vascular disrupting agent in tumors.

    PubMed

    Alhasan, Mustafa K; Liu, Li; Lewis, Matthew A; Magnusson, Jennifer; Mason, Ralph P

    2012-01-01

    Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO).During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs.The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent.

  13. Diagnostic instrumentation aboard ISS: just-in-time training for non-physician crewmembers.

    PubMed

    Foale, C Michael; Kaleri, Alexander Y; Sargsyan, Ashot E; Hamilton, Douglas R; Melton, Shannon; Martin, David; Dulchavsky, Scott A

    2005-06-01

    The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed "just-in-time" training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This "just-in-time" concept was used to support real-time remote expert guidance to complete ultrasound examinations using the ISS Human Research Facility (HRF). An American and Russian ISS crewmember received 2 h of "hands on" ultrasound training 8 mo prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember 6 d prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. Results of the CD-ROM-based OPE session were used to modify the instructions during a complete 35-min real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were adequate for clinical decision making. Complex ultrasound experiments with expert guidance were performed with high accuracy following limited preflight training and multimedia based in-flight review, despite a 2-s communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, facilitates the successful performance of ultrasound examinations on orbit and may have additional terrestrial and space applications.

  14. Diagnostic instrumentation aboard ISS: just-in-time training for non-physician crewmembers

    NASA Technical Reports Server (NTRS)

    Foale, C. Michael; Kaleri, Alexander Y.; Sargsyan, Ashot E.; Hamilton, Douglas R.; Melton, Shannon; Martin, David; Dulchavsky, Scott A.

    2005-01-01

    INTRODUCTION: The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed "just-in-time" training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This "just-in-time" concept was used to support real-time remote expert guidance to complete ultrasound examinations using the ISS Human Research Facility (HRF). METHODS: An American and Russian ISS crewmember received 2 h of "hands on" ultrasound training 8 mo prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember 6 d prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. RESULTS: Results of the CD-ROM-based OPE session were used to modify the instructions during a complete 35-min real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were adequate for clinical decision making. CONCLUSIONS: Complex ultrasound experiments with expert guidance were performed with high accuracy following limited preflight training and multimedia based in-flight review, despite a 2-s communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, facilitates the successful performance of ultrasound examinations on orbit and may have additional terrestrial and space applications.

  15. Virtual Guidance Ultrasound: A Tool to Obtain Diagnostic Ultrasound for Remote Environments

    NASA Technical Reports Server (NTRS)

    Caine,Timothy L.; Martin David S.; Matz, Timothy; Lee, Stuart M. C.; Stenger, Michael B.; Platts, Steven H.

    2012-01-01

    Astronauts currently acquire ultrasound images on the International Space Station with the assistance of real-time remote guidance from an ultrasound expert in Mission Control. Remote guidance will not be feasible when significant communication delays exist during exploration missions beyond low-Earth orbit. For example, there may be as much as a 20- minute delay in communications between the Earth and Mars. Virtual-guidance, a pre-recorded audio-visual tutorial viewed in real-time, is a viable modality for minimally trained scanners to obtain diagnostically-adequate images of clinically relevant anatomical structures in an autonomous manner. METHODS: Inexperienced ultrasound operators were recruited to perform carotid artery (n = 10) and ophthalmic (n = 9) ultrasound examinations using virtual guidance as their only instructional tool. In the carotid group, each each untrained operator acquired two-dimensional, pulsed, and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. RESULTS: Eight of the 10 carotid studies were judged to be diagnostically adequate. With one exception the quality of all the ophthalmic images were adequate to excellent. CONCLUSION: Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by untrained operators with instruction only from an audio/video tutorial viewed in real time while scanning. This form of quick-response-guidance, can be developed for other ultrasound examinations, represents an opportunity to acquire important medical and scientific information for NASA flight surgeons and researchers when trained medical personnel are not present. Further, virtual guidance will allow untrained personnel to autonomously obtain important medical information in remote locations on Earth where communication is difficult or absent.

  16. Intraprocedure contrast enhanced ultrasound: the value in assessing the effect of ultrasound-guided high intensity focused ultrasound ablation for uterine fibroids.

    PubMed

    Peng, Song; Hu, Liang; Chen, Wenzhi; Chen, Jinyun; Yang, Caiyong; Wang, Xi; Zhang, Rong; Wang, Zhibiao; Zhang, Lian

    2015-04-01

    To investigate the value of microbubble contrast-enhanced ultrasound (CEUS) in evaluating the treatment response of uterine fibroids to HIFU ablation. Sixty-eight patients with a solitary uterine fibroid from the First Affiliated Hospital of Chongqing Medical University were included and analyzed. All patients underwent pre- and post-treatment magnetic resonance imaging (MRI) with a standardized protocol, as well as pre-evaluation, intraprocedure, and immediate post-treatment CEUS. CEUS and MRI were compared by different radiologists. In comparison with MRI, CEUS showed that the size of fibroids, volume of fibroids, size of non-perfused regions, non-perfused volume (NPV) or fractional ablation (NPV ratio) was similar to that of MRI. In terms of CEUS examination results, the median volume of fibroids was 75.2 (interquartile range, 34.2-127.3) cm(3), the median non-perfused volume was 54.9 (interquartile range, 28.0-98.1) cm(3), the mean fractional ablation was 83.7±13.6 (range, 30.0-100.0)%. In terms of MRI examination results, the median volume of fibroids was 74.1 (interquartile range, 33.4-116.2) cm(3). On the basis of contrast-enhanced T1-weighted images immediately after HIFU treatment, the median non-perfused volume was 58.5 (interquartile range, 27.7-100.0) cm(3), the average fractional ablation was 84.2±14.2 (range, 40.0-100.0)%. CEUS clearly showed the size of fibroids and the non-perfused areas of the fibroid. Results from CEUS correlated well with results obtained from MRI. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Thyroid Nodule Size at Ultrasound as a Predictor of Malignancy and Final Pathologic Size.

    PubMed

    Cavallo, Allison; Johnson, Daniel N; White, Michael G; Siddiqui, Saaduddin; Antic, Tatjana; Mathew, Melvy; Grogan, Raymon H; Angelos, Peter; Kaplan, Edwin L; Cipriani, Nicole A

    2017-05-01

    Thyroid-related mortality has remained constant despite the increasing incidence of thyroid carcinoma. Most thyroid nodules are benign; therefore, ultrasound and fine needle aspiration (FNA) are integral in cancer screening. We hypothesize that increased nodule size at ultrasound does not predict malignancy and correlation between nodule size at ultrasound and pathologic exam is good. Resected thyroids with preoperative ultrasounds were identified. Nodule size at ultrasound, FNA diagnosis by Bethesda category, size at pathologic examination, and final histologic diagnosis were recorded. Nodule characteristics at ultrasound and FNA diagnoses were correlated with gross characteristics and histologic diagnoses. Nodules for which correlation could not be established were excluded. Of 1003 nodules from 659 patients, 26% were malignant. Nodules <2 cm had the highest malignancy rate (∼30%). Risk was similar (∼20%) for nodules ≥2 cm. Of the 548 subject to FNA, 38% were malignant. Decreasing malignancy rates were observed with increasing size (57% for nodules <1 cm to 20% for nodules >6 cm). At ultrasound size cutoffs of 2, 3, 4, and 5 cm, smaller nodules had higher malignancy rates than larger nodules. Of the 455 not subject to FNA, 11% were malignant. Ultrasound size alone is a poor predictor of malignancy, but a relatively good predictor of final pathologic size (R 2  = 0.748), with less correlation at larger sizes. In nodules subject to FNA, false negative diagnoses were highest (6-8%) in nodules 3-6 cm, mostly due to encapsulated follicular variant of papillary carcinoma. Thyroid nodule size is inversely related to malignancy risk, as larger nodules have lower malignancy rates. However, the relationship of size to malignancy varies by FNA status. All nodules (regardless of FNA status) demonstrate a risk trough at ≥2 cm. Nodules subject to FNA show step-wise decline in malignancy rates by size, demonstrating that size alone should not be considered as an independent risk factor. Size at ultrasound shows relatively good correlation with final pathologic size. False negative rates are low in this series. Lesions with the appropriate constellation of clinical and radiographic findings should undergo FNA regardless of size. Both size and FNA diagnosis should influence the clinical decision-making process.

  18. Short-term Clinical Results of Manipulation Under Ultrasound-Guided Brachial Plexus Block in Patients with Idiopathic Frozen Shoulder and Diabetic Secondary Frozen Shoulder.

    PubMed

    Ando, Akira; Hamada, Junichiro; Hagiwara, Yoshihiro; Sekiguchi, Takuya; Koide, Masashi; Itoi, Eiji

    2018-01-01

    This study examined the effectiveness of manipulation under ultrasound-guided brachial plexus block in patients with recalcitrant idiopathic frozen shoulder and diabetic secondary frozen shoulder (diabetic frozen shoulder). Forty-four idiopathic frozen shoulders and 10 diabetic frozen shoulders with failed conservative treatment for at least 3 months were included in this study. The manipulation was performed under ultrasound-guided brachial plexus block and visual analogue scale, range of motion, and Constant scores were measured before manipulation and at the last follow-up examination. No major complications were observed during the procedure. Sufficient improvement was not obtained in two patients during the procedure and to avoid complications, the procedure was discontinued and subsequently arthroscopic capsular release was performed. Visual analogue scale, range of motion towards all directions, and Constant scores were significantly improved after the manipulation in both the idiopathic frozen shoulder and diabetic frozen shoulder groups, however the diabetic group showed inferior results compared with those of the idiopathic group. This manipulation was effective and shortened the duration of symptoms in most of the idiopathic and diabetic frozen shoulders without major complications during the procedure. Diabetic frozen shoulder showed inferior clinical results and difficulty in recovery in range of motion, which indicated that diabetic frozen shoulder should be discussed as a different entity.

  19. Chest wall segmentation in automated 3D breast ultrasound scans.

    PubMed

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Nanobubble Ultrasound Contrast Agents for Enhanced Delivery of Thermal Sensitizer to Tumors Undergoing Radiofrequency Ablation

    PubMed Central

    Perera, Reshani H.; Solorio, Luis; Wu, Hanping; Gangolli, Mihika; Silverman, Eric; Hernandez, Christopher; Peiris, Pubudu M.; Broome, Ann-Marie

    2013-01-01

    Purpose Pluronic has been shown to sensitize various tumor cell lines to chemotherapy and hyperthermia by altering the membrane fluidity, depleting ATP, and modulating the heat shock protein 70 expression. In our prior work, Pluronic was also used to formulate nanosized ultrasound contrast agents. In the current study we evaluate the use of these contrast agents as vehicles for image-guided delivery of Pluronic to improve outcomes of tumor radiofrequency (RF) ablation. Methods Lipid-shelled Pluronic nanobubbles were prepared and examined for size distribution, zeta potential, stability, biodistribution, accumulation of nanobubbles in the tumor, and treatment efficacy. LS174-T xenograft tumor-bearing mice were used to evaluate tumor growth suppression and measure treatment efficacy after RF ablation. Results The average diameter of Pluronic bubbles was 230 nm, and initial bubble echogenicity was 16 dB. In vitro, cells exposed to Pluronic nanobubbles exhibited low cytotoxicity in the absence of ultrasound, even if heat (43°C) was applied. When the cells were exposed to Pluronic nanobubbles, heat, and ultrasound; viability was significantly reduced. In vivo, tumors treated with ultrasound-modulated nanobubbles prior to RF ablation showed a significant reduction in growth compared to the RF alone (P<0.05). Conclusion Lipid and Pluronic-shelled, echogenic nanobubbles combined with ultrasound modulation can serve as an effective theranostic method for sensitization of tumors to RF ablation. PMID:23943542

  1. Nanobubble ultrasound contrast agents for enhanced delivery of thermal sensitizer to tumors undergoing radiofrequency ablation.

    PubMed

    Perera, Reshani H; Solorio, Luis; Wu, Hanping; Gangolli, Mihika; Silverman, Eric; Hernandez, Christopher; Peiris, Pubudu M; Broome, Ann-Marie; Exner, Agata A

    2014-06-01

    Pluronic has been shown to sensitize various tumor cell lines to chemotherapy and hyperthermia by altering the membrane fluidity, depleting ATP, and modulating the heat shock protein 70 expression. In our prior work, Pluronic was also used to formulate nanosized ultrasound contrast agents. In the current study we evaluate the use of these contrast agents as vehicles for image-guided delivery of Pluronic to improve outcomes of tumor radiofrequency (RF) ablation. Lipid-shelled Pluronic nanobubbles were prepared and examined for size distribution, zeta potential, stability, biodistribution, accumulation of nanobubbles in the tumor, and treatment efficacy. LS174-T xenograft tumor-bearing mice were used to evaluate tumor growth suppression and measure treatment efficacy after RF ablation. The average diameter of Pluronic bubbles was 230 nm, and initial bubble echogenicity was 16 dB. In vitro, cells exposed to Pluronic nanobubbles exhibited low cytotoxicity in the absence of ultrasound, even if heat (43 ºC) was applied. When the cells were exposed to Pluronic nanobubbles, heat, and ultrasound; viability was significantly reduced. In vivo, tumors treated with ultrasound-modulated nanobubbles prior to RF ablation showed a significant reduction in growth compared to the RF alone (P<0.05). Lipid and Pluronic-shelled, echogenic nanobubbles combined with ultrasound modulation can serve as an effective theranostic method for sensitization of tumors to RF ablation.

  2. Ultrasound credentialing in North American emergency department systems with ultrasound fellowships: a cross-sectional survey.

    PubMed

    Bellamkonda, Venkatesh R; Shokoohi, Hamid; Alsaawi, Abdulmohsen; Ding, Ru; Campbell, Ronna L; Liu, Yiju Teresa; Boniface, Keith S

    2015-10-01

    To describe the credentialing systems of North American emergency department systems (EDS) with emergency ultrasound (EUS) fellowship programmes. This is a prospective, cross-sectional, survey-based study of North American EUS fellowships using a 62-item, pilot-tested, web-based survey instrument assessing credentialing and training systems. The American College of Emergency Physicians (ACEP) distributed the surveys using SNAP survey (Snap Surveys Ltd, Portsmouth, New Hampshire, USA). Over 6 months, 75 eligible programmes were surveyed, 55 responded (73% response rate); 1 declined to participate leaving 54 participating programmes. Less than 20% of EDS credential nurses, physician assistants, nurse practitioners and students in EUS. Respondent EDS reported having an average of 4.2 ± 3.3 ultrasound faculty members (faculty identifying their career focus as EUS). The median number of annual point-of-care ultrasounds reported was 5000 (IQR 3000-8000). 30 EDS (56%) credential each examination individually and 48 EDS (89%) use ACEP credentialing criteria. 61% of fellowship leadership believe their credentialing system is either satisfactory or very satisfactory (Cronbach's coefficient α=0.84). The data show heterogeneity among North American EDS with EUS fellowship programmes with regard to credentialing systems despite published guidelines from the ACEP and Canadian Emergency Ultrasound Society. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Technical aspects of contrast-enhanced ultrasound (CEUS) examinations: tips and tricks.

    PubMed

    Greis, C

    2014-01-01

    Ultrasound contrast agents have substantially extended the clinical value of ultrasound, allowing the assessment of blood flow and distribution in real-time down to microcapillary level. Selective imaging of contrast agent signals requires a contrast-specific imaging mode on the ultrasound scanner, allowing real-time separation of tissue and contrast agent signals. The creation of a contrast image requires a specific interaction between the insonated ultrasound wave and the contrast agent microbubbles, leading to persistent oscillation of the bubbles. Several technical and procedural parameters have a significant influence on the quality of CEUS images and should be controlled carefully to obtain good image quality and a reliable diagnosis. Achieving the proper balance between the respective parameters is a matter of technical knowledge and experience. Appropriate training and education should be mandatory for every investigator performing CEUS examinations.

  4. Imaging features of hepatic angiomyolipomas on real-time contrast-enhanced ultrasound

    PubMed Central

    Wang, Z; Xu, H-X; Xie, X-Y; Xie, X-H; Kuang, M; Xu, Z-F; Liu, G-J; Chen, L-D; Lin, M-X; Lu, M-D

    2010-01-01

    The aim of this study was to evaluate the imaging features of hepatic angiomyolipoma (AML) on contrast-enhanced ultrasound (CEUS). The imaging features of 12 pathologically proven hepatic AML lesions in 10 patients who had undergone baseline ultrasound (BUS) and CEUS examinations were evaluated retrospectively. The enhancement extent, pattern and dynamic change, along with the enhancement process, on CEUS were analysed. The diagnostic results of BUS and CEUS before pathological examination were also recorded. The results showed that 75% (9/12) of the AML lesions exhibited mixed echogenicity on BUS and most showed remarkable hyperechogenicity in combination with a hypoechoic or anechoic portion. Arterial flow signals were detected in 75% (9/12) of the lesions on colour Doppler imaging. On CEUS, 66.7% (n = 8) of the 12 lesions exhibited hyperenhancement in the arterial phase, slight hyperenhancement (n = 2) or isoenhancement (n = 6) in the portal phase, and slight hyperenhancement (n = 1) or isoenhancement (n = 7) in the late phase. Three (25%) lesions exhibited hyperenhancement in the arterial phase and hypoenhancement in both portal and late phases. One (8.3%) lesion exhibited hypoenhancement throughout the CEUS process. Before pathological examination with BUS, only 3 (25%) lesions were correctly diagnosed as hepatic AML. Conversely, on CEUS, correct diagnoses were made for 66.8% (8/12) of hepatic AMLs. Therefore, arterial hyperenhancement and subsequent sustained enhancement on CEUS were found in the majority of hepatic AMLs. The combination of BUS and CEUS leads to the correct diagnosis in the majority of hepatic AMLs, and is higher than the success rate achieved by BUS alone. PMID:19723766

  5. Development of support system to handle ultrasound probe by coordinated motion with medical robot.

    PubMed

    Masuda, Kohji; Takachi, Yuuki; Urayama, Yasuhiro; Yoshinaga, Takashi

    2011-01-01

    We have developed a support system using our ultrasound diagnosis robot, which is able to support manual handling of ultrasound probe in echography to alleviate fatigue of examiner. This system realizes a coordinated motion according to the motion of the probe, which is hold by the robot and is moved by an examiner. We have established four kinds of situations, which are initial fixation, coordinate motions with/without contact on the body surface, and automatic chase motion of an internal organ. The system recognizes when the examiner grasps the ultrasound probe by 6-axis force sensor and touches it on body surface by processing echograms. Not only unskilled examiners but also a professional sonographer have evaluated the performance of the system after elucidating multiple parameters for compliance control and self-weight and moment compensation of the probe. As the results, this system has the potential to be able to support advanced diagnosis for conventional echography.

  6. Factors Predictive of Improved Abdominal Ultrasound Visualization after Oral Administration of Simethicone.

    PubMed

    Marsico, Maria; Gabbani, Tommaso; Casseri, Tommaso; Biagini, Maria Rosa

    2016-11-01

    Ultrasonography is a non-invasive, accurate and low-cost technique used to study the upper abdomen, but it has reduced reliability in the study of the pancreas and retroperitoneum. Simethicone is a well-known emulsifying agent that has been used to improve ultrasonographic visualization. The aim of this study was to identify anthropometric parameters that are able to predict a good response to simethicone in improving ultrasonographic visualization of abdominal structures. One hundred twenty-seven patients were recruited. After basal examination, their anthropometric parameters were collected. Patients with an incomplete upper abdominal examination because of gastrointestinal gas have greater body mass index, waist circumference and abdominal wall thickness. In our study, the best anthropometric parameter for identifying patients with poor visualization at abdominal ultrasound examination is waist circumference. Using a cutoff of 84 cm, we can identify patients with poor visibility at abdominal ultrasound examination (group B) with a sensitivity of 90%. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. [Clinical characteristics of choroidal metastasis].

    PubMed

    Zhang, Hui-rong; Ma, Zhi-zhong; Feng, Yun; Guo, Tong

    2009-04-01

    To study the clinical characteristics of choroidal metastasis (CM) to promote the early diagnosis and differentiate from other choroidal tumors. Retrospective clinical observational cases. All patients with choroidal metastasis underwent ophthalmologic examination including best corrected visual acuity (VA), slit-lamp examination, binocular indirect funduscopy, color photography, fundus fluorescein angiography (FFA), indocyanine-green angiography (ICGA), optical coherence tomography (OCT), A and B scan ultrasound examination, magnetic resonance image (MRI) as well as CT of the thorax, etc. Nine eyes of 5 patients with CM were examined. Unilateral choroidal involvement was present in 1 patient, bilateral in 4 cases. There were 1 case male and 4 case females. The age of these patients ranged from 31 to 56 years, median 45 years. Ocular symptoms included reduced vision in 4 patients and visual distortion in 1 patient. Visual acuity was 20/400- < 20/63 in four eyes; 20/63- < 20/30 in two eyes and >or= 20/30 in three eyes. The primary cancer site was in the lung in 3 patients, in the breast in 1 patient and in the stomach in 1 patient. Fundus characteristics: Typical CM was more often in the plateau-shaped than in the dome-shaped; yellow-white or mottled in color and associated with subretinal fluid and retinal detachment. The tumor was found in the macular area and juxtapapillary area in 6 eyes, in the area between the macula and the equator in 3 eyes. CM was solitary in 5 eyes and showed multiple lesions in 4 eyes. By FA the lesions showed mottled hyperfluorescence in early stage and leakage in late stage. By ICGA the lesion showed blocked fluorescence and hypofluorescence. Choroidal mass showed moderate irregular internal reflectivity in A-scan ultrasound. B-scan showed a plateau-shaped solid mass. MRI examination of the lesion revealed moderate short T1W and T2W signals. The cancer antigen increased to 16.28 and 4.95 microg/L in two cases. CA125 increased to 160.5 kU/L in one case. The choroid is the most common site for metastases. CM may precede the diagnosis of primary tumor. Evaluation of A, B scan ultrasound, CT of thorax and cancer antigen test may be important to exclude primary carcinoma from lung and breast in patients with yellow-white in color, plateau-shaped choroidal lesions, especially in both eyes, and without known metastatic diseases.

  8. [The study of new soft one-piece PHEMA keratoprosthesis implanted into alkali burned rabbits cornea].

    PubMed

    Bai, Hua; Huang, Yi-fei; Wang, Li-qiang

    2013-10-01

    This study was to evaluate clinical results of two types soft one-piece keratoprosthesis (KPros) made of PHEMA implanted to alkali burned rabbit corneas. Experimental study. Twelve pieces KPros were implanted alkali burned rabbit corneas(type I and II, 6 pieces respectively). The examinations including slit-lamp, fundus photography,B-ultrasound and ultrasound biomicroscopy (UBM) were carried out. All Kpros were stable and no complications happened including conjunctiva flap dehiscence, aqueous leak and infection. IOP were normal by finger touch. B-ultrasound show no retina detachment and UBM show synechia in most animals (10 case). Retroprosthetic membrane happened in type I (3 case) . Visible conjunctiva hyperplasia covering the optical region happened in all KPros. (1) The same material, integrated design, maybe eliminating the material interface problem. (2)Simple surgical skills. (3)IOP measurement is possible because of soft material. (4)KPro I do not need removal of the lens and vitrectomy. The projecting portion of KPro II may reduce the incidence of proliferative membrane. Long term effects need more cases and further observation.

  9. Twisted intra-abdominal cyst in a neonate: a surprise revelation.

    PubMed

    Mohamed, Ferzine; Telugu, Ramesh Babu; Karl, Immanuel Sampath

    2017-08-08

    We, herein, present a male neonate with an antenatally detected intra-abdominal cyst who presented at 18 days of life at which time, the ultrasound revealed a 5×4 cm cyst. Since he was asymptomatic, we planned to repeat the ultrasound a month later and operate if the cyst showed no regression. However, a week later, he presented with an acute abdomen, irritable cry and a repeat ultrasound showing a larger (8×6 cm) cystic mass with debris within. He was taken up for an emergency laparotomy. Intraoperatively, the cyst was found arising from the left lateral abdominal wall free from all structures with a twisted pedicle. Histopathology surprisingly revealed seminiferous tubules within the cyst wall with the vas deferens, thus confirming the diagnosis of a torsion of intra-abdominal testis. Hence, we emphasise the importance of examining for an undescended testis when dealing with a male neonate presenting with a cystic intra-abdominal mass. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. [Brachial artery pseudoaneurysm: a rare but serious complication in hemodialysis patients with arteriovenous fistula].

    PubMed

    Mancini, Andrea; Castriotta, Giuseppe; Angelini, Pernina; Bozzi, Michele; Giancaspro, Vincenzo; La Raia, Elvira; Nisi, Maria Teresa; Proscia, Anna Rita; Tarantino, Giuseppe; Vitale, Ottavia; Cuzzola, Cristoforo

    2017-06-01

    A pseudoaneurysm or false aneurysm of the brachial artery is an uncommon occurrence in patients receiving hemodialysis with arteriovenous fistula (AVF). We describe the case of a 76-year-old woman presenting with a large, tender, pulsatile mass in the right antecubital region 10 cm from the AVF. B-mode ultrasound examination revealed a saccular hematoma. Color doppler showed a recirculation movement of blood, creating a two colors image called "Korean flag". The patient was transferred to the surgical unit where she first underwent ultrasound-guided compression and then surgical repair of the pseudoaneurysm. Two weeks after surgery the AVF was used again as an access for hemodialysis. Differentiating between a false and a true aneurysm based on ultrasound is not always straightforward. Doppler ultrasound findings can be decisive for the early diagnosis of a pseudoaneurysm to ensure proper treatment planning given the dangerous complications of ruptures. Treatment options include: compression, percutaneous thrombin injection, endovascular exclusion with covered stents, aneurysmectomy and surgical repair. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.

  11. Complications and adequacy of transplant kidney biopsies: A comparison of techniques.

    PubMed

    Plattner, Brett W; Chen, Pauline; Cross, Richard; Leavitt, Matthew A; Killen, Paul D; Heung, Michael

    2018-05-01

    Kidney biopsies are an essential tool in the diagnosis and management of kidney diseases, particularly in kidney transplant recipients. Biopsies carry a risk for serious complications and not all biopsies achieve adequate tissue. We examined the impact of kidney biopsy technique on complications and biopsy adequacy. The cohort consisted of consecutive kidney transplant patients undergoing biopsy by one of three techniques: ultrasound localization, real-time ultrasound guidance, and ultrasound-guided trocar placement. Variables of interest included patient characteristics and procedural characteristics. The primary outcome was serious complication attributable to kidney biopsy, and the secondary outcome was biopsy adequacy as defined by Banff criteria. Among 263 patients undergoing biopsy, 27 (10.3%) had a complication (14 with gross hematuria, 10 requiring blood transfusion, 3 requiring an unplanned interventional radiology procedure, 1 kidney loss; no deaths). Complications were more common among patients biopsied using ultrasound-guided trocar compared to real-time ultrasound and ultrasound localization (21.4% vs 7.9% vs 7.1%, respectively, p = 0.008). After adjusting for patient and procedure characteristics, technique was no longer significantly associated with complication. Biopsy adequacy was significantly higher when using ultrasound localization and real-time ultrasound compared to ultrasound-guided trocar (84.6% vs 86.8% vs 69.6%, p = 0.029), and this finding persisted in adjusted analysis. Kidney biopsy complications appear to be similar when using any of the three techniques examined in our study. However, ultrasound-guided trocar technique may yield lower biopsy adequacy when compared to non-trocar techniques.

  12. Jaundice in a pregnant woman.

    PubMed

    Ibrahimi, Sophiane; Mroué, Abbas Ali; Francois, Erik; Jagodzinski, Robert

    2017-01-01

    A 34-year-old woman in the 22nd week of gestation presented with generalized pruritis and weight loss since the first trimester of pregnancy. Physical examination revealed cutaneous scratch lesions, jaundice, and hepatomegaly. Blood tests revealed cholestasis with elevated direct bilirubinemia. Auto-antibody and viral hepatitis tests were negative. Liver ultrasound was normal. The initial diagnosis was cholestasis of pregnancy. However despite treatment with ursodeoxycholic acid, the patient did not improve. Delivery was by cesarean section at the 26th week of pregnancy for obstetrical reasons. A new liver ultrasound showed a heterogeneous nodular mass. Nuclear magnetic resonance (NMR) of the liver showed an 11-cm mass centered on the hilum, dilated intrahepatic bile ducts, involvement of the hepatic veins, and hilar adenopathy. A liver biopsy revealed fibrolamellar hepatocellular carcinoma (FHC). © Acta Gastro-Enterologica Belgica.

  13. [The significance of electronic CTG for intrauterine volvulus in the 32nd week of gestation].

    PubMed

    Schiermeier, S; Reinhard, J; Westhof, G; Hatzmann, W

    2008-02-01

    Intrauterine intestinal volvulus is a difficult diagnosis to make, but has life-threatening implications for the fetus. We present a case of vulvulus without malrotation in a single fetus revealed in the 32nd gestation week in a 44-year-old woman. The presenting complaint of this patient was reduced fetal movements. Ultrasound examination showed a normal result except for a dilated stomach. Doppler ultrasound results were within the normal range. Computed cardiotocography (CTG) showed pathological results for acceleration and suspect values for variability. Short-term variability (STV) was at 2.80 ms. Due to the pathological computed CTG results a Caesarian section was carried out. The newborn received prompt postnatal surgical treatment and continues to be in good overall condition.

  14. Magnetic nanobubbles with potential for targeted drug delivery and trimodal imaging in breast cancer: an in vitro study.

    PubMed

    Song, Weixiang; Luo, Yindeng; Zhao, Yajing; Liu, Xinjie; Zhao, Jiannong; Luo, Jie; Zhang, Qunxia; Ran, Haitao; Wang, Zhigang; Guo, Dajing

    2017-05-01

    The aim of this study was to improve tumor-targeted therapy for breast cancer by designing magnetic nanobubbles with the potential for targeted drug delivery and multimodal imaging. Herceptin-decorated and ultrasmall superparamagnetic iron oxide (USPIO)/paclitaxel (PTX)-embedded nanobubbles (PTX-USPIO-HER-NBs) were manufactured by combining a modified double-emulsion evaporation process with carbodiimide technique. PTX-USPIO-HER-NBs were examined for characterization, specific cell-targeting ability and multimodal imaging. PTX-USPIO-HER-NBs exhibited excellent entrapment efficiency of Herceptin/PTX/USPIO and showed greater cytotoxic effects than other delivery platforms. Low-frequency ultrasound triggered accelerated PTX release. Moreover, the magnetic nanobubbles were able to enhance ultrasound, magnetic resonance and photoacoustics trimodal imaging. These results suggest that PTX-USPIO-HER-NBs have potential as a multimodal contrast agent and as a system for ultrasound-triggered drug release in breast cancer.

  15. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology.

    PubMed

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  16. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology

    PubMed Central

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation. PMID:28100998

  17. Αntioxidant activity of Cynara scolymus L. and Cynara cardunculus L. extracts obtained by different extraction techniques.

    PubMed

    Kollia, Eleni; Markaki, Panagiota; Zoumpoulakis, Panagiotis; Proestos, Charalampos

    2017-05-01

    Extracts of different parts (heads, bracts and stems) of Cynara cardunculus L. (cardoon) and Cynara scolymus L. (globe artichoke), obtained by two different extraction techniques (Ultrasound-Assisted Extraction (UAE) and classical extraction (CE)) were examined and compared for their total phenolic content (TPC) and their antioxidant activity. Moreover, infusions of the plant's parts were also analysed and compared to aforementioned samples. Results showed that cardoon's heads extract (obtained by Ultrasound-Assisted Extraction) displayed the highest TPC values (1.57 mg Gallic Acid Equivalents (GAE) g -1 fresh weight (fw)), the highest DPPH • scavenging activity (IC50; 0.91 mg ml -1 ) and the highest ABTS •+ radical scavenging capacity (2.08 mg Trolox Equivalents (TE) g -1 fw) compared to infusions and other extracts studied. Moreover, Ultrasound-Assisted Extraction technique proved to be more appropriate and effective for the extraction of antiradical and phenolic compounds.

  18. Electrolytic echo enhancement: a novel method to make needles more reflective to ultrasound.

    PubMed

    Cockburn, John F; Khosh, Stefan K

    2014-04-01

    This study examines the effect of augmenting the ultrasound reflectivity of needles using a novel electrolytic echo enhancement method. Needles were connected by a lead to the negative terminal of a 4.5 V direct current source. A grounding pad, connected to the positive terminal, was positioned on the undersurface of an ex vivo ox liver phantom. During needle insertion into the liver, electrolysis was induced creating a layer of gas on the needle electrode. Analysis of images showed a significant increase in needle brightness using electrolytic echo enhancement. Brightness was found to increase by a factor of ×3.6 compared with controls (P < 0.001). Electrolytic echo enhancement has the potential to make ultrasound-guided procedures safer and quicker for patients and increase the confidence of operators in their ability to see the whole needle including its tip. © 2014 The Royal Australian and New Zealand College of Radiologists.

  19. American Medical Society for Sports Medicine recommended sports ultrasound curriculum for sports medicine fellowships.

    PubMed

    Finnoff, Jonathan T; Berkoff, David; Brennan, Fred; DiFiori, John; Hall, Mederic M; Harmon, Kimberly; Lavallee, Mark; Martin, Sean; Smith, Jay; Stovak, Mark

    2015-01-01

    The following sports ultrasound (SPORTS US) curriculum is a revision of the curriculum developed by the American Medical Society for Sports Medicine (AMSSM) in 2010. Several changes have been made to the curriculum with the primary aim of providing a pathway by which a sports medicine fellow can obtain sufficient SPORTS US training to become proficient in the core competencies of SPORTS US. The core competencies of SPORTS US are outlined in the learning objectives section of this document. The term "SPORTS US" was purposefully chosen rather than "musculoskeletal ultrasound" (MSK US) because it was recognized by the panel that the evolving field of SPORTS US encompasses non-MSK applications of ultrasound such as the FAST examination (focused assessment with sonography for trauma). Although the SPORTS US core competencies in this curriculum are all MSK in nature, they represent the minimum SPORTS US knowledge a sports medicine fellow should acquire during fellowship. However, additional training in more advanced MSK and non-MSK applications of ultrasound can be provided at the fellowship director's discretion. Completion of this SPORTS US curriculum fulfills the American Institute of Ultrasound in Medicine's (AIUM) requirements to perform an MSK US examination and the prerequisites for the American Registry for Diagnostic Medical Sonography's (ARDMS) MSK sonography certification examination.

  20. Fetal tele-echography using a robotic arm and a satellite link.

    PubMed

    Arbeille, P; Ruiz, J; Herve, P; Chevillot, M; Poisson, G; Perrotin, F

    2005-09-01

    To design a method for conducting fetal ultrasound examinations in isolated hospital sites using a dedicated remotely controlled robotic arm (tele-echography). Tele-echography was performed from our hospital (expert center) on 29 pregnant women in an isolated maternity hospital (patient site) 1700 km away, and findings were compared with those of conventional ultrasound examinations. At the patient site, a robotic arm holding the real ultrasound probe was placed on the patient's abdomen by an assistant with no experience of performing ultrasound. The robotic arm, remotely controlled with a fictive (expert) probe, reproduced the exact movements (tilting and rotating) of the expert hand on the real ultrasound probe. In 93.1% of the cases, all biometric parameters, placental location and amniotic fluid volume, were correctly assessed using the teleoperated robotic arm. In two cases, femur length could not be correctly measured. The mean duration of fetal ultrasound examination was 14 min (range, 10-18) and 18 min (range, 13-23) by conventional and tele-echography methods, respectively. The mean number of times the robotic arm was repositioned on the patient's abdomen was seven (range, 5-9). Tele-echography using a robotic arm provides the main information needed to assess fetal growth and the intrauterine environment within a limited period of time.

  1. Value of contrast-enhanced ultrasound in the differential diagnosis of gallbladder lesion

    PubMed Central

    Zhang, Hui-Ping; Bai, Min; Gu, Ji-Ying; He, Ying-Qian; Qiao, Xiao-Hui; Du, Lian-Fang

    2018-01-01

    AIM To describe contrast-enhanced ultrasound (CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study included 105 gallbladder lesions. Before surgical resection and pathological examination, conventional ultrasound and CEUS were performed to examine for lesions. Then, all the lesions were diagnosed as (1) benign, (2) probably benign, (3) probably malignant or (4) malignant using both conventional ultrasound and CEUS. The CEUS features of these gallbladder lesions were analyzed and diagnostic efficiency between conventional ultrasound and CEUS was compared. RESULTS There were total 17 cases of gallbladder cancer and 88 cases of benign lesion. Some gallbladder lesions had typical characteristics on CEUS (e.g., gallbladder adenomyomatosis had typical characteristics of small nonenhanced areas on CEUS). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 94.1%, 95.5%, 80.0%, 98.8% and 95.2%, respectively. These were significantly higher than conventional ultrasound (82.4%, 89.8%, 60.9%, 96.3% and 88.6%, respectively). CEUS had an accuracy of 100% for gallbladder sludge and CEUS helped in differential diagnosis among gallbladder polyps, gallbladder adenoma and gallbladder cancer. CONCLUSION CEUS may provide more useful information and improve the diagnosis efficiency for the diagnosis of gallbladder lesions than conventional ultrasound. PMID:29456413

  2. Diagnostic accuracy of ultrasonography in detection of blunt abdominal trauma and comparison of early and late ultrasonography 24 hours after trauma.

    PubMed

    Feyzi, Ali; Rad, Masoud Pezeshki; Ahanchi, Navid; Firoozabadi, Jalil

    2015-01-01

    Despite the advantages of ultrasound scan, its use as a screening tool in blunt abdominal trauma is controversial. The aim of this study was to evaluate the diagnostic value of early and late ultrasound in patients with blunt abdominal trauma (BAT). In this study which was performed in a level I trauma center, firstly, 2418 patients with BAT had ultrasound (US) examination by two trauma expert radiologists. Results were compared with the best available gold standards such as laparotomy, CT, repeated ultrasound or clinical course follow-up. Then, 400 patients with BAT were examined by a trained residency student. In the first phase, sensitivity, specificity, negative predictive value, positive predictive value and accuracy of ultrasound were 97%, 98.1%, 99.7%, 83% and 98% respectively. In the second phase, they were 97.3%, 97.2%, 97.7%, 96.8% and 97.3% for the early and 98.5%, 97.6%, 98.5%, 97.5% and 98% for the late ultrasound respectively. Results obtained from this study indicate that negative ultrasound findings associated with negative clinical observation virtually exclude abdominal injury, and confirmation by performing other tests is unnecessary. High sensitivity and negative predictive value is achieved if ultrasound is performed by expert trauma radiologist.

  3. Development of a Duplex Ultrasound Simulator and Preliminary Validation of Velocity Measurements in Carotid Artery Models.

    PubMed

    Zierler, R Eugene; Leotta, Daniel F; Sansom, Kurt; Aliseda, Alberto; Anderson, Mark D; Sheehan, Florence H

    2016-07-01

    Duplex ultrasound scanning with B-mode imaging and both color Doppler and Doppler spectral waveforms is relied upon for diagnosis of vascular pathology and selection of patients for further evaluation and treatment. In most duplex ultrasound applications, classification of disease severity is based primarily on alterations in blood flow velocities, particularly the peak systolic velocity (PSV) obtained from Doppler spectral waveforms. We developed a duplex ultrasound simulator for training and assessment of scanning skills. Duplex ultrasound cases were prepared from 2-dimensional (2D) images of normal and stenotic carotid arteries by reconstructing the common carotid, internal carotid, and external carotid arteries in 3 dimensions and computationally simulating blood flow velocity fields within the lumen. The simulator displays a 2D B-mode image corresponding to transducer position on a mannequin, overlaid by color coding of velocity data. A spectral waveform is generated according to examiner-defined settings (depth and size of the Doppler sample volume, beam steering, Doppler beam angle, and pulse repetition frequency or scale). The accuracy of the simulator was assessed by comparing the PSV measured from the spectral waveforms with the true PSV which was derived from the computational flow model based on the size and location of the sample volume within the artery. Three expert examiners made a total of 36 carotid artery PSV measurements based on the simulated cases. The PSV measured by the examiners deviated from true PSV by 8% ± 5% (N = 36). The deviation in PSV did not differ significantly between artery segments, normal and stenotic arteries, or examiners. To our knowledge, this is the first simulation of duplex ultrasound that can create and display real-time color Doppler images and Doppler spectral waveforms. The results demonstrate that an examiner can measure PSV from the spectral waveforms using the settings on the simulator with a mean absolute error in the velocity measurement of less than 10%. With the addition of cases with a range of pathologies, this duplex ultrasound simulator will be a useful tool for training health-care providers in vascular ultrasound applications and for assessing their skills in an objective and quantitative manner. © The Author(s) 2016.

  4. Levator hiatal area as a risk factor for cystocele recurrence after surgery: a prospective study.

    PubMed

    Vergeldt, T F M; Notten, K J B; Weemhoff, M; van Kuijk, S M J; Mulder, F E M; Beets-Tan, R G; Vliegen, R F A; Gondrie, E T C M; Bergmans, M G M; Roovers, J P W R; Kluivers, K B

    2015-07-01

    To investigate whether increased levator hiatal area, measured preoperatively, was independently associated with anatom-ical cystocele recurrence 12 months after anterior colporrhaphy. Multicentre prospective cohort study. Nine teaching hospitals in the Netherlands. Women planned for conventional anterior colporrhaphy without mesh. Women underwent physical examination, translabial three-dimensional (3D) ultrasound and magnetic resonance imaging (MRI) prior to surgery. At 12 months after surgery the physical examination was repeated. Women with and without anatomical cystocele recurrence were compared to assess the association with levator hiatal area on 3D ultrasound, levator hiatal area on MRI, and potential confounding factors. The receiver operating characteristic (ROC) curve was created to quantify the discriminative ability of using levator hiatal area to predict anatomical cystocele recurrence. Of 139 included women, 76 (54.7%) had anatomical cystocele recurrence. Preoperative stage 3 or 4 and increased levator hiatal area during Valsalva on ultrasound were significantly associated with cystocele recurrence, with odds ratios of 3.47 (95% confidence interval, 95% CI 1.66-7.28) and 1.06 (95% CI 1.01-1.11) respectively. The area under the ROC curve was 0.60 (95% CI 0.51-0.70) for levator hiatal area during Valsalva on ultrasound, and 0.65 (95% CI 0.55-0.71) for preoperative Pelvic Organ Prolapse Quantification (POP-Q) stage. Increased levator hiatal area during Valsalva on ultrasound prior to surgery and preoperative stage 3 or 4 are independent risk factors for anatomical cystocele recurrence after anterior colporrhaphy; however, increased levator hiatal area as the sole factor for predicting anatomical cystocele recurrence after surgery shows poor test characteristics. © 2015 Royal College of Obstetricians and Gynaecologists.

  5. HDlive rendering images of the fetal stomach: a preliminary report.

    PubMed

    Inubashiri, Eisuke; Abe, Kiyotaka; Watanabe, Yukio; Akutagawa, Noriyuki; Kuroki, Katumaru; Sugawara, Masaki; Maeda, Nobuhiko; Minami, Kunihiro; Nomura, Yasuhiro

    2015-01-01

    This study aimed to show reconstruction of the fetal stomach using the HDlive rendering mode in ultrasound. Seventeen healthy singleton fetuses at 18-34 weeks' gestational age were observed using the HDlive rendering mode of ultrasound in utero. In all of the fetuses, we identified specific spatial structures, including macroscopic anatomical features (e.g., the pyrous, cardia, fundus, and great curvature) of the fetal stomach, using the HDlive rendering mode. In particular, HDlive rendering images showed remarkably fine details that appeared as if they were being viewed under an endoscope, with visible rugal folds after 27 weeks' gestational age. Our study suggests that the HDlive rendering mode can be used as an additional method for evaluating the fetal stomach. The HDlive rendering mode shows detailed 3D structural images and anatomically realistic images of the fetal stomach. This technique may be effective in prenatal diagnosis for examining detailed information of fetal organs.

  6. Seeing Is Believing: Evaluating a Point-of-Care Ultrasound Curriculum for 1st-Year Medical Students.

    PubMed

    Nelson, Bret P; Hojsak, Joanne; Dei Rossi, Elizabeth; Karani, Reena; Narula, Jagat

    2017-01-01

    Point-of-care ultrasound has been a novel addition to undergraduate medical education at a few medical schools. The impact is not fully understood, and few rigorous assessments of educational outcomes exist. This study assessed the impact of a point-of-care ultrasound curriculum on image acquisition, interpretation, and student and faculty perceptions of the course. All 142 first-year medical students completed a curriculum on ultrasound physics and instrumentation, cardiac, thoracic, and abdominal imaging. A flipped classroom model of preclass tutorials and tests augmenting live, hands-on scanning sessions was incorporated into the physical examination course. Students and faculty completed surveys on impressions of the curriculum, and all students under-went competency assessments with standardized patients. The curriculum was a mandatory part of the physical examination course and was taught by experienced clinician-sonographers as well as faculty who do not routinely perform sonography in their clinical practice. Students and faculty agreed that the physical examination course was the right time to introduce ultrasound (87% and 80%). Students demonstrated proper use of the ultrasound machine functions (M score = 91.55), and cardiac, thoracic, and abdominal system assessments (M score = 80.35, 79.58, and 71.57, respectively). Students and faculty valued the curriculum, and students demonstrated basic competency in performance and interpretation of ultrasound. Further study is needed to determine how to best incorporate this emerging technology into a robust learning experience for medical students.

  7. A Severe Case of Pigmentary Glaucoma in a Child With a Family History of Pigment Dispersion Syndrome.

    PubMed

    Aragno, Vittoria; Zeboulon, Pierre; Baudouin, Christophe; Labbé, Antoine

    2016-08-01

    To report a case of severe pigmentary glaucoma (PG) in a 13-year-old boy of a family affected by pigment dispersion syndrome (PDS). A 13-year-old child was referred to our hospital for severe bilateral glaucoma. A complete ophthalmologic evaluation including refraction, intraocular pressure, central corneal thickness, slit-lamp biomicroscopy, gonioscopy, fundus examination, and ultrasound biomicroscopy was performed. Family members were also examined and a family pedigree was obtained. Ophthalmologic examination revealed a severe bilateral PG with Krukenberg spindle and a widely open heavily pigmented iridocorneal angle. Ultrasound biomicroscopy showed a deep anterior chamber with pronounced iris concavity in both eyes. Within his family, his 15-year-old sister and 7-year-old brother were both affected by PDS diagnosed on gonioscopy findings. We report for the first time a severe case of pediatric PG with a family history of PDS. This case demonstrates that accurate screening is necessary in cases of familial PDS and PG, even in the pediatric population.

  8. Percutaneous Image-Guided Aspiration and Sclerosis of Adventitial Cystic Disease of the Femoral Vein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jason M.; Kiankhooy, Armin; Bertges, Daniel J.

    2009-07-15

    Adventitial cystic disease (ACD), also known as cystic mucoid or myxomatous degeneration, is a rare vascular disease mainly seen in arteries. Seventeen cases have been reported in the world literature. We report the first known case of ACD successfully treated with percutaneous image-guided ethanol sclerosis. Computed tomography showed a cystic mass adherent to the wall of the common femoral vein. An ultrasound examination revealed a deep venous thrombosis of the leg, secondary to extrinsic compression of the common femoral vein. Three years prior to our procedure, the cyst was aspirated, which partially relieved the patient's symptoms. Over the following 3more » years the patient's symptoms worsened and a 10-cm discrepancy in thigh size developed, in addition to the deep venous thrombosis associated with lower-extremity edema. Using ultrasound guidance and fluoroscopic control, the cyst was drained and then sclerosed with absolute ethanol. The patient's symptoms and leg swelling resolved completely within several weeks. Follow-up physical examination and duplex ultrasound 6 months following sclerosis demonstrated resolution of the symptoms and elimination of the extrinsic compression effect of the ACD on the common femoral vein.« less

  9. Diagnosis of hyperfunctional thyroid nodules: impact of US-elastography.

    PubMed

    Ruhlmann, M; Stebner, V; Görges, R; Farahati, J; Simon, D; Bockisch, A; Rosenbaum-Krumme, S; Nagarajah, J

    2014-01-01

    Several studies described the ultrasound based real-time elastography (USE) having a high sensitivity, specificity and negative predictive value in the diagnosis of suspicious thyroid nodules. Recently published studies called these results into question. Until now the usefulness of USE in the diagnosis of scintigraphically hyperfunctional thyroid nodules is not examined. This study included 135 hyperfunctional thyroid nodules of 102 consecutive patients. The following attributes of the nodules were analyzed: stiffness with the USE using scores of Rago or Asteria and ultrasound criteria using TIRADS. 94 of the examined thyroid nodules (70%) were rated as hard (suspicious for malignancy) and 41 nodules (30%) as soft (not suspicious) with a specificity of 30%. The scoring systems of Rago and Asteria showed no significant difference. Applying the TIRADS criteria 44 nodules (33%) have a higher risk for malignancy (33 nodules TIRADS 4a, 11 nodules TIRADS 4b). Combining USE and TIRADS 32 nodules (24%) are categorized as suspicious (intersection of hard nodules that are categorized as TIRADS 4a or 4b). Ultrasound based real-time elastography cannot identify scintigraphically hyperfunctional thyroid nodules as benign nodules reliably. Its accuracy in the assessment of at least "hot" thyroid nodules is to be questioned.

  10. The study of ultrasonic irradiation effects on solid state powders of HTc superconductor YBa2Cu3O7-x

    NASA Astrophysics Data System (ADS)

    Kargar, Mahboubeh; Khoshnevisan, Bahram

    2016-03-01

    In this paper, an ultrasound assisted solid state synthesis method for high-temperature (HTc) YBa2Cu3O7-x (YBCO) superconductor nanostructures with different morphologies is presented. Here, the routine heat treatment of the powder mixture of as-prepared precursors is followed by the ultrasound irradiation inside various alcoholic solutions. Not only the influence of the ultrasound irradiation intensity and duration but also the influence of different solvents such as ethanol, methanol and 1-butanol with various vapor pressures and so various destruction powers were also studied on the morphology and particle size of the products. The various morphologies were studied by scanning electron microscope (SEM) which not only have been affected by intensity and type of alcoholic solvent but also sonication time and ultrasound power have significant role as well. Formation of the YBCO superconducting phase was examined by using Rietveld refinement of X-ray diffraction (XRD) which indicates the crystalline preferred growth in c-axis orientation in crystal. Magnetic susceptibility measurements showed the ultrasound waves had no important effect on the onset critical temperature of the prepared nanorods (about 91.64 K) which is compared with the bulk samples (Tc ˜ 92K).

  11. Ultrasound as a monitoring tool for cystic echinococcosis in sheep.

    PubMed

    Dore, F; Varcasia, A; Pipia, A P; Sanna, G; Pinna Parpaglia, M L; Corda, A; Romig, T; Scala, A

    2014-06-16

    An ultrasound-based survey for cystic echinococcosis (CE) in sheep was carried out in Sardinia in 2012. The study was done on three farms (A, B, C) which had been pre-selected for different CE prevalence levels (A: >80%, B: 50-80%, C: <50%). In total, 129 sheep were examined on the farms using portable ultrasound equipment (A: n=51, B: n=30, C: n=48). Within a period of 20 days after ultrasound examination, all sheep were slaughtered and underwent a parasitological post-mortem examination for cysts in the liver and lungs. With post-mortem as gold standard, ultrasonography gave a test sensitivity of 88.7% and a specificity of 75.9%, while the positive and negative predictive values were 81.8% and 84.6%, respectively. When only sheep with fertile cysts were considered, the sensitivity of the test increased to 100%. We conclude that the ultrasound examination of the liver in sheep - using state-of-the-art technology - is a sensitive and specific diagnostic tool, which is cost-effective, highly appropriate for field use and requires only moderate time (no shaving required). The method can also be applied to other livestock species and will be useful tool in epidemiological studies, monitoring schemes and vaccination/control trials. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Comparison of Endoanal Ultrasound with Clinical Diagnosis in Anal Fistula Assessment.

    PubMed

    Sirikurnpiboon, Siripong; Phadhana-anake, Oradee; Awapittaya, Burin

    2016-02-01

    Anal fistula anatomy and its relationship with anal sphincters are important factors influencing the results of surgical management. Pre-operative definitions of fistulous track(s) and the internal opening play a primary role in minimizing damage to the sphincters and recurrence of the fistula. To evaluate the relative accuracy of digital examination and endoanal ultrasound for pre-operative assessment of anal fistula by comparing operative findings. A retrospective review was conducted of all patients with anal fistula admitted to the surgical unit between May 2008 and May 2012. Physical examination and hydrogen peroxide-enhanced endoanal ultrasound (utilising a 10 MHz endoprobe, HITACHI: EUB-7500), were performed in 142 consecutive patients. Results were matched with surgical features to establish their accuracy in preoperative anal fistula assessment. A total of 142 patients (107 men, 35 women), 28 of whom had had previous surgery, were included in the study. Their mean age was 40 (range 18-71) years and their mean BMI was 26.37 (range 17.30-36.11) kg/m². The majority of the fistulas were transphincteric (90.4%) and the rest were intersphincteric (9.6%). The accuracy rates of clinical examination and endoanal ultrasound were 55.63 and 95.07 percent (p < 0.01), respectively. Endoanal ultrasound is superior to digital examination for pre-operative classification of anal fistula

  13. Introducing universal ultrasound screening for developmental dysplasia of the hip doubled the treatment rate.

    PubMed

    Olsen, Stine F; Blom, Hans C; Rosendahl, Karen

    2018-02-01

    There is no evidence on the effect of universal ultrasound screening on developmental dysplasia of the hip. We examined the impact of adding an ultrasound examination to a one examiner clinical screening strategy on treatment, follow-up rates and the number of cases detected late in a low-prevalence population. All eligible babies born at Kongsberg Hospital, Norway, from 1998 to 2006 (n = 4245) underwent both clinical and ultrasound hip examinations within three days of life. Indications for immediate treatment were positive Barlow or Ortolani manoeuvres and, or, sonographic dysplasia. Sonographic immature hips were followed until normalisation. Treatment rates and rates from the 1989 to 1997 prestudy period (n = 3594), including late diagnoses, were collected from hospital records. Treatment was initiated in 90 (2.1%) infants (74 girls), 63 (70%) from birth, compared to 33 (0.9%) during the prestudy period. The follow-up rate did not change (11%). There were two (0.5/1000) and four (1.0/1000) cases detected late, respectively. No one underwent surgery during the first year of life and no avascular necrosis was seen. Adding universal ultrasound to clinical screening performed by the same, experienced paediatrician doubled the treatment rate, without influencing the already low numbers of late cases. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  14. In-vivo monitoring of development of cholangiocarcinoma induced with C. sinensis and N-nitrosodimethylamine in Syrian golen hamsters using ultrasonography and magnetic resonance imaging: a preliminary study.

    PubMed

    Woo, Hyunsik; Han, Joon Koo; Kim, Jung Hoon; Hong, Sung-Tae; Uddin, Md Hafiz; Jang, Ja-June

    2017-04-01

    The purpose of this study is to evaluate high-resolution ultrasound and magnetic resonance imaging (MRI) in monitoring of cholangiocarcinoma in the hamsters with C. sinensis infection and N-nitrosodimethylamine (NDMA). Twenty-four male Syrian golden hamsters of were divided into four groups composed of five hamsters as control, five hamsters receiving 30 metacercariae of C. sinensis per each hamster, five hamsters receiving NDMA in drinking water, and nine hamsters receiving both metacercariae and NDMA. Ultrasound was performed every other week from baseline to the 12th week of infection. MRI and histopathologic examination was done from the 4th week to 12th week. Cholangiocarcinomas appeared as early as the 6th week of infection. There were 12 cholangiocarcinomas, nine and ten of which were demonstrated by ultrasound and MRI, respectively. Ultrasound and MRI findings of cholangiocarcinomas in the hamsters were similar to those of the mass-forming intrahepatic cholangiocarcinomas in humans. Ultrasound and MRI also showed other findings of disease progression such as periductal increased echogenicity or signal intensity, ductal dilatation, complicated cysts, and sludges in the gallbladder. High-resolution ultrasound and MRI can monitor and detect the occurrence of cholangiocarcinoma in the hamsters non-invasively. • High-resolution ultrasound and MRI can monitor occurrence of cholangiocarcinoma in the hamsters. • Cholangiocarcinomas were detected as early as the 6th week after C. sinensis infection. • Axial T2-weighted MRI demonstrated cholangiocarcinomas and various inflammatory findings in the hamsters.

  15. Hunger Games: Interactive Ultrasound Imaging for Learning Gastrointestinal Physiology.

    PubMed

    Kafer, Ilana; Rennie, William; Noor, Ali; Pellerito, John S

    2017-02-01

    Ultrasound is playing an increasingly important role in medical student education. Although most uses of ultrasound have focused on learning purely anatomic relationships or augmentation of the physical examination, there is little documentation of the value of ultrasound as a learning tool regarding physiology alone or in association with anatomy. We devised an interactive learning session for first-year medical students using ultrasound to combine both anatomic and physiologic principles as an integration of gastrointestinal and vascular function. The incorporation of our activity, The Hunger Games, provides the foundation for a powerful integration tool for medical student education. © 2016 by the American Institute of Ultrasound in Medicine.

  16. Imaging in gynecological disease. 10: Clinical and ultrasound characteristics of decidualized endometriomas surgically removed during pregnancy.

    PubMed

    Mascilini, F; Moruzzi, C; Giansiracusa, C; Guastafierro, F; Savelli, L; De Meis, L; Epstein, E; Timor-Tritsch, I E; Mailath-Pokorny, M; Ercoli, A; Exacoustos, C; Benacerraf, B R; Valentin, L; Testa, A C

    2014-09-01

    To describe the clinical history and ultrasound findings in women with decidualized endometriomas surgically removed during pregnancy. In this retrospective study, women with a histological diagnosis of decidualized endometrioma during pregnancy who had undergone preoperative ultrasound examination were identified from the databases of seven ultrasound centers. The ultrasound appearance of the tumors was described on the basis of ultrasound images, ultrasound reports and research protocols (when applicable) by one author from each center using the terms and definitions of the International Ovarian Tumor Analysis (IOTA) group. In addition, two authors reviewed together available digital ultrasound images and used pattern recognition to describe the typical ultrasound appearance of decidualized endometriomas. Eighteen eligible women were identified. Median age was 34 (range, 20-43) years. Median gestational age at surgical removal of the decidualized endometrioma was 18 (range, 11-41) weeks. Seventeen women (94%) were asymptomatic and one presented with pelvic pain. In three of the 18 women an ultrasound diagnosis of endometrioma had been made before pregnancy. The original ultrasound examiner was uncertain whether the mass was benign or malignant in 10 (56%) women and suggested a diagnosis of benignity in nine (50%) women, borderline in eight women (44%), and invasive malignancy in one (6%) woman. Seventeen decidualized endometriomas contained a papillary projection, and in 16 of these at least one of the papillary projections was vascularized at power or color Doppler examination. The number of cyst locules varied between one (n = 11) and four. No woman had ascites. When using pattern recognition, most decidualized endometriomas (14/17, 82%) were described as manifesting vascularized rounded papillary projections with a smooth contour in an ovarian cyst with one or a few cyst locules and ground-glass or low-level echogenicity of the cyst fluid. Rounded vascularized papillary projections with smooth contours within an ovarian cyst with cyst contents of ground-glass or low-level echogenicity are typical of surgically removed decidualized endometriomas in pregnant women, most of whom are asymptomatic. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  17. Ultrasound in telemedicine: its impact in high-risk obstetric health care delivery.

    PubMed

    Long, Megan Chang; Angtuaco, Teresita; Lowery, Curtis

    2014-09-01

    The aim of this study was to determine the impact of Antenatal and Neonatal Guidelines, Education, and Learning System (ANGELS), a statewide telemedicine project, on health care delivery to patients with high-risk pregnancies in Arkansas. With institutional review board approval, a Health Insurance Portability and Accountability Act-compliant retrospective review, in which the requirement for informed patient consent was waived, was performed. The population studied is the Arkansas maternal Medicaid population. Data for evaluation were collected from maternal Medicaid claims, ANGELS administrative records, and birth records from the Arkansas Vital Statistics record system. Data collected from before the inception of ANGELS (2001-2003) were compared with data collected after the inception of ANGELS (2004-2007).Antenatal and Neonatal Guidelines, Education, and Learning System is a multidisciplinary, multifaceted telemedicine program designed in Arkansas to enhance high-risk obstetric health care delivery across the state. An essential component of the program is real-time interactive targeted level II ultrasound examination of patients. Since the inception of the ANGELS program in 2003, a growing number of telemedicine consultations and real-time ultrasound examinations are being performed every year. The number and percentage of high-risk pregnancies identified each year show a slight decrease since inception of the ANGELS program, and findings suggest that identification of high-risk pregnancies is shifting from the second trimester to the first trimester, but trends vary over time. Antenatal and Neonatal Guidelines, Education, and Learning System has created a telemedicine network across the state that has made possible, among many other things, access to real-time level II ultrasound examinations and consultations. This program has ultimately led to improved prenatal access across the state.

  18. Does Ultrasound-Enhanced Instruction of Musculoskeletal Anatomy Improve Physical Examination Skills of First-Year Medical Students?

    PubMed

    Walrod, Bryant J; Schroeder, Allison; Conroy, Mark J; Boucher, Laura C; Bockbrader, Marcia; Way, David P; McCamey, Kendra L; Hartz, Clinton A; Jonesco, Michael A; Bahner, David P

    2018-01-01

    Ultrasound imaging is commonly used to teach basic anatomy to medical students. The purpose of this study was to determine whether learning musculoskeletal anatomy with ultrasound improved performance on medical students' musculoskeletal physical examination skills. Twenty-seven first-year medical students were randomly assigned to 1 of 2 instructional groups: either shoulder or knee. Both groups received a lecture followed by hands-on ultrasound scanning on live human models of the assigned joint. After instruction, students were assessed on their ability to accurately palpate 4 anatomic landmarks: the acromioclavicular joint, the proximal long-head biceps tendon, and the medial and lateral joint lines of the knee. Performance scores were based on both accuracy and time. A total physical examination performance score was derived for each joint. Scores for instructional groups were compared by a 2-way analysis of variance with 1 repeated measure. Significant findings were further analyzed with post hoc tests. All students performed significantly better on the knee examination, irrespective of instructional group (F = 14.9; df = 1.25; P = .001). Moreover, the shoulder instruction group performed significantly better than the knee group on the overall assessment (t = -3.0; df = 25; P < .01). Post hoc analyses revealed that differences in group performance were due to the shoulder group's higher scores on palpation of the biceps tendon (t = -2.8; df = 25; P = .01), a soft tissue landmark. Both groups performed similarly on palpation of all other anatomic structures. The use of ultrasound appears to provide an educational advantage when learning musculoskeletal physical examination of soft tissue landmarks. © 2017 by the American Institute of Ultrasound in Medicine.

  19. Ultrasound diagnosis of penile fracture.

    PubMed

    Nomura, Jason T; Sierzenski, Paul R

    2010-04-01

    Rupture of the corpus cavernosum, penile fracture, is an uncommon occurrence. Diagnosis is straightforward when classical historical and physical examination findings are present. However, atypical presentations can make the diagnosis difficult. Review the literature supporting use of ultrasound for the diagnosis of penile fracture. Review of the ultrasonographic findings in patients with penile fracture. A 32-year-old man presented with penile ecchymosis after sex but lacking several historical and physical examination elements for a diagnosis of penile fracture. Ultrasound performed by the treating physician revealed rupture of the tunica albuginea and presence of a hematoma, leading to a diagnosis of penile fracture. Ultrasound is a simple, efficient, and non-invasive imaging method to assist in the diagnosis of penile fracture. Copyright 2010 Elsevier Inc. All rights reserved.

  20. Hepatobiliary ultrasonography

    NASA Astrophysics Data System (ADS)

    Sembiring, J.

    2018-03-01

    Ultrasound is one of the most widely used imaging technologies in medicine. It is portable, free of radiation risk, non-invasive and relatively inexpensive when compared with other imaging modalities, such as magnetic resonance and computed tomography. Ultrasound is a useful procedure for evaluating many structures organ in our body. An examination may include the entirety of the abdomen and retroperitoneum from a single organ to several organs. An abdominal ultrasound examination survey would include the liver, gallbladder, biliary tree, pancreas, spleen, kidneys and retroperitoneal structures. It needsperforming when there is a valid medical reason.

  1. Physics and instrumentation of ultrasound.

    PubMed

    Lawrence, John P

    2007-08-01

    A thorough understanding of the physics of ultrasound waves and the instrumentation will provide the user with a better understanding of the capabilities and limitations of ultrasound equipment. The ultrasound machine combines two technologies: image production (M-mode and 2-dimensional imaging) with Doppler assessment (continuous and pulse wave as well as color-flow mapping). These distinct technologies have been combined to provide the examiner with the ability to make accurate and comprehensive diagnoses and guide therapeutic intervention.

  2. Routine screening for fetal anomalies: expectations.

    PubMed

    Goldberg, James D

    2004-03-01

    Ultrasound has become a routine part of prenatal care. Despite this, the sensitivity and specificity of the procedure is unclear to many patients and healthcare providers. In a small study from Canada, 54.9% of women reported that they had received no information about ultrasound before their examination. In addition, 37.2% of women indicated that they were unaware of any fetal problems that ultrasound could not detect. Most centers that perform ultrasound do not have their own statistics regarding sensitivity and specificity; it is necessary to rely on large collaborative studies. Unfortunately, wide variations exist in these studies with detection rates for fetal anomalies between 13.3% and 82.4%. The Eurofetus study is the largest prospective study performed to date and because of the time and expense involved in this type of study, a similar study is not likely to be repeated. The overall fetal detection rate for anomalous fetuses was 64.1%. It is important to note that in this study, ultrasounds were performed in tertiary centers with significant experience in detecting fetal malformations. The RADIUS study also demonstrated a significantly improved detection rate of anomalies before 24 weeks in tertiary versus community centers (35% versus 13%). Two concepts seem to emerge from reviewing these data. First, patients must be made aware of the limitations of ultrasound in detecting fetal anomalies. This information is critical to allow them to make informed decisions whether to undergo ultrasound examination and to prepare them for potential outcomes.Second, to achieve the detection rates reported in the Eurofetus study, ultrasound examination must be performed in centers that have extensive experience in the detection of fetal anomalies.

  3. [Ultrasound diagnostics of muscle and tendon injuries].

    PubMed

    Stević, Ruza; Masulović, Dragan

    2009-01-01

    Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow- up of healing process. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. The study included 170 patients (148 male and 22 female), mean age 29.6 years (range 14-60 years). All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Traumatic lesions of muscles were diagnosed in 113 patients (66.7%) and tendon injuries in 57 cases (33.2%). The muscle changes detected by ultrasonography were the following: 70 (61.9%) partial and two (1.76%) complete ruptures, 22 (19.46%) haematoma, 9 (7.96%) strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively). Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8%) ruptures and 36 (66.1%) tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  4. Ultrasound as visual feedback in speech habilitation: exploring consultative use in rural British Columbia, Canada.

    PubMed

    Bernhardt, May B; Bacsfalvi, Penelope; Adler-Bock, Marcy; Shimizu, Reiko; Cheney, Audrey; Giesbrecht, Nathan; O'connell, Maureen; Sirianni, Jason; Radanov, Bosko

    2008-02-01

    Ultrasound has shown promise as a visual feedback tool in speech therapy. Rural clients, however, often have minimal access to new technologies. The purpose of the current study was to evaluate consultative treatment using ultrasound in rural communities. Two speech-language pathologists (SLPs) trained in ultrasound use provided consultation with ultrasound in rural British Columbia to 13 school-aged children with residual speech impairments. Local SLPs provided treatment without ultrasound before and after the consultation. Speech samples were transcribed phonetically by independent trained listeners. Eleven children showed greater gains in production of the principal target /[image omitted]/ after the ultrasound consultation. Four of the seven participants who received more consultation time with ultrasound showed greatest improvement. Individual client factors also affected outcomes. The current study was a quasi-experimental clinic-based study. Larger, controlled experimental studies are needed to provide ultimate evaluation of the consultative use of ultrasound in speech therapy.

  5. Performance of chest ultrasound in pediatric pneumonia.

    PubMed

    Claes, Anne-Sophie; Clapuyt, Philippe; Menten, Renaud; Michoux, Nicolas; Dumitriu, Dana

    2017-03-01

    The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. 143 children (mean age 3 years; limits between 8days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4mm; for consolidations visible on both techniques the mean size was 26mm (p<0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus reducing radiation exposure in this population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Key findings from the International Ovarian Tumor Analysis (IOTA) study: an approach to the optimal ultrasound based characterisation of adnexal pathology

    PubMed Central

    Bourne, Tom; De Rijdt, Sylvie; Van Holsbeke, Caroline; Sayasneh, Ahmad; Valentin, Lil; Van Calster, Ben; Timmerman, Dirk

    2015-01-01

    Abstract The principal aim of the IOTA project has been to develop approaches to the evaluation of adnexal pathology using ultrasound that can be transferred to all examiners. Creating models that use simple, easily reproducible ultrasound characteristics is one approach. PMID:28191150

  7. Ultrasound - Breast

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...

  8. Validation of Greyscale-Based Quantitative Ultrasound in Manual Wheelchair Users

    PubMed Central

    Collinger, Jennifer L.; Fullerton, Bradley; Impink, Bradley G.; Koontz, Alicia M.; Boninger, Michael L.

    2010-01-01

    Objective The primary aim of this study is to establish the validity of greyscale-based quantitative ultrasound (QUS) measures of the biceps and supraspinatus tendons. Design Nine QUS measures of the biceps and supraspinatus tendons were computed from ultrasound images collected from sixty-seven manual wheelchair users. Shoulder pathology was measured using questionnaires, physical examination maneuvers, and a clinical ultrasound grading scale. Results Increased age, duration of wheelchair use, and body mass correlated with a darker, more homogenous tendon appearance. Subjects with pain during physical examination tests for biceps tenderness and acromioclavicular joint tenderness exhibited significantly different supraspinatus QUS values. Even when controlling for tendon depth, QUS measures of the biceps tendon differed significantly between subjects with healthy tendons, mild tendinosis, and severe tendinosis. Clinical grading of supraspinatus tendon health was correlated with QUS measures of the supraspinatus tendon. Conclusions Quantitative ultrasound is valid method to quantify tendinopathy and may allow for early detection of tendinosis. Manual wheelchair users are at a high risk for developing shoulder tendon pathology and may benefit from quantitative ultrasound-based research that focuses on identifying interventions designed to reduce this risk. PMID:20407304

  9. Head and Neck Ultrasound Education-A Multimodal Educational Approach in the Predoctoral Setting: A Pilot Study.

    PubMed

    Bernard, Stewart; Richardson, Clare; Hamann, Carsten R; Lee, Steve; Dinh, Vi Am

    2015-08-01

    With the increased implementation of ultrasound in medical education, it is important to continually improve instructional methods. In this study, we demonstrate that by augmenting the traditional methods of instructor demonstration and student practice on a healthy volunteer with additional modalities, such as didactic presentation, simulated pathologic cases, and simulated procedures, students gain a more comprehensive understanding of and confidence in ultrasound technique and pathology. A multimodal curriculum was developed and applied to head and neck ultrasound sessions of our institution's Ultrasound Symposium. Participants were asked to fill out surveys rating each instructional modality as well as preinstructional and postinstructional confidence. The survey results were divided into a group of first- and second-year medical students who had previous ultrasound training and a group of third- and fourth-year students who were ultrasound "naïve." The survey showed that the first- and second-year student group (n = 8) had an average preinstructional confidence of 4.14/10 compared to 1.44/10 in the third- and fourth-year student group (n = 9) (P = .003). Following the instructional sessions, the students' confidence increased respectively to 8.14/10 and 7.78/10 (P= .53), showing a 4.00 (96%) increase in the first- and second-year group and a 6.34 (440%) increase in the third- and fourth-year group. The combined results of all student teaching modality ratings showed that instructor demonstration was rated the highest (9.47) and computerized simulation lowest (8.25). Overall, our study shows that multimodal ultrasound instruction was beneficial in increasing both ultrasound-trained and ultrasound-naïve medical students' confidence in head and neck ultrasound. © 2015 by the American Institute of Ultrasound in Medicine.

  10. ‘Essential but not always available when needed’ – an interview study of physicians’ experiences and views regarding use of obstetric ultrasound in Tanzania

    PubMed Central

    Åhman, Annika; Kidanto, Hussein Lesio; Ngarina, Matilda; Edvardsson, Kristina; Small, Rhonda; Mogren, Ingrid

    2016-01-01

    Background The value of obstetric ultrasound in high-income countries has been extensively explored but evidence is still lacking regarding the role of obstetric ultrasound in low-income countries. Objective We aimed to explore experiences and views among physicians working in obstetric care in Tanzania, on the role of obstetric ultrasound in relation to clinical management. Design A qualitative study design was applied. Data were collected in 2015, through 16 individual interviews with physicians practicing in obstetric care at hospitals in an urban setting in Tanzania. Data were analyzed using qualitative content analysis. Results Use of obstetric ultrasound in the management of complicated pregnancy was much appreciated by participating physicians, although they expressed considerable concern about the lack of ultrasound equipment and staff able to conduct the examinations. These limitations were recognized as restricting physicians’ ability to manage complications adequately during pregnancy and birth. Better availability of ultrasound was requested to improve obstetric management. Concerns were also raised regarding pregnant women's lack of knowledge and understanding of medical issues which could make counseling in relation to obstetric ultrasound difficult. Although the physicians perceived a positive attitude toward ultrasound among most pregnant women, occasionally they came across women who feared that ultrasound might harm the fetus. Conclusions There seems to be a need to provide more physicians in antenatal care in Tanzania with ultrasound training to enable them to conduct obstetric ultrasound examinations and interpret the results themselves. Physicians also need to acquire adequate counseling skills as counseling can be especially challenging in this setting where many expectant parents have low levels of education. Providers of obstetric care and policy makers in Tanzania will need to take measures to ensure appropriate use of the scarce resources in the Tanzanian health care system and prevent the potential risk of overuse of ultrasound in pregnancy. PMID:27452066

  11. The Effects of Ultrasound on Biological Systems: Site

    NASA Astrophysics Data System (ADS)

    El-Karmi, Anan M.

    Earlier studies (Dinno et al., Ultrasound Med. Biol. 15:461 -470; 1989) demonstrated that ultrasound at therapeutic intensities causes large increases in total conductance (G_{rm t}) of frog skin. These changes were attributed to non-thermal mechanisms, primarily, cavitation. In this study, the site(s) and mechanism(s) of action of ultrasound for the increase in G_{rm t} were examined. The reversible changes in G_{rm t } and sodium current were monitored in real time as a function of ultrasound exposure. Amiloride, a sodium channel blocker, was used to differentiate between cellular (G_{rm c}) and paracellular (G_{rm s}) pathways in the presence and absence of ultrasound. No significant changes were detected in G_ {rm c}. However, changes in G _{rm s} were significant. These results demonstrate that most of the increase in G _{rm t} due to ultrasound is taking place in the paracellular pathways. Sodium channels were not significantly affected by ultrasound. Thus, the changes in G_{rm c} are not specific. The effects of ultrasound were examined in the presence of radical scavengers and antioxidants. The increase in G_{rm t} due to ultrasound was significantly minimized in the presence of cystamine, cysteamine, and sodium ascorbate. This demonstrates that free radicals and other reactive species generated by cavitation are causing the increase in G_ {rm t}, possibly by acting from inside the cells. Radical scavengers and antioxidants are providing protection from oxidative damage but are not involved in the recovery of G_{ rm t} towards steady state values after sonication. The role of Ca^{2+} in the effects of ultrasound was examined since many of the cellular reactions involved in tissue recovery are dependent on the intracellular availability of free Ca^{2+}. The percentage increase in G_{rm t} in the presence of Ca^{2+} was larger than in its absence (140% vs. 27%). The time constant for G_{rm t} to return to steady state was longer in calcium-free solutions (122 vs. 18 minutes). This demonstrates that the biological effects of ultrasound are influenced by Ca^ {2+}. The larger increases in G _{rm t} and the time constants confirm other studies addressing the role of Ca ^{2+} in potentiating lipid peroxidation by free radicals, and the role of calcium ions in the formation of tight junctions.

  12. Comparison of the didactic lecture with the simulation/model approach for the teaching of a novel perioperative ultrasound curriculum to anesthesiology residents.

    PubMed

    Ramsingh, Davinder; Alexander, Brenton; Le, Khanhvan; Williams, Wendell; Canales, Cecilia; Cannesson, Maxime

    2014-09-01

    To expose residents to two methods of education for point-of-care ultrasound, a traditional didactic lecture and a model/simulation-based lecture, which focus on concepts of cardiopulmonary function, volume status, and evaluation of severe thoracic/abdominal injuries; and to assess which method is more effective. Single-center, prospective, blinded trial. University hospital. Anesthesiology residents who were assigned to an educational day during the two-month research study period. Residents were allocated to two groups to receive either a 90-minute, one-on-one didactic lecture or a 90-minute lecture in a simulation center, during which they practiced on a human model and simulation mannequin (normal pathology). Data points included a pre-lecture multiple-choice test, post-lecture multiple-choice test, and post-lecture, human model-based examination. Post-lecture tests were performed within three weeks of the lecture. An experienced sonographer who was blinded to the education modality graded the model-based skill assessment examinations. Participants completed a follow-up survey to assess the perceptions of the quality of their instruction between the two groups. 20 residents completed the study. No differences were noted between the two groups in pre-lecture test scores (P = 0.97), but significantly higher scores for the model/simulation group occurred on both the post-lecture multiple choice (P = 0.038) and post-lecture model (P = 0.041) examinations. Follow-up resident surveys showed significantly higher scores in the model/simulation group regarding overall interest in perioperative ultrasound (P = 0.047) as well understanding of the physiologic concepts (P = 0.021). A model/simulation-based based lecture series may be more effective in teaching the skills needed to perform a point-of-care ultrasound examination to anesthesiology residents. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Anesthesiologists' learning curves for bedside qualitative ultrasound assessment of gastric content: a cohort study.

    PubMed

    Arzola, Cristian; Carvalho, Jose C A; Cubillos, Javier; Ye, Xiang Y; Perlas, Anahi

    2013-08-01

    Focused assessment of the gastric antrum by ultrasound is a feasible tool to evaluate the quality of the stomach content. We aimed to determine the amount of training an anesthesiologist would need to achieve competence in the bedside ultrasound technique for qualitative assessment of gastric content. Six anesthesiologists underwent a teaching intervention followed by a formative assessment; then learning curves were constructed. Participants received didactic teaching (reading material, picture library, and lecture) and an interactive hands-on workshop on live models directed by an expert sonographer. The participants were instructed on how to perform a systematic qualitative assessment to diagnose one of three distinct categories of gastric content (empty, clear fluid, solid) in healthy volunteers. Individual learning curves were constructed using the cumulative sum method, and competence was defined as a 90% success rate in a series of ultrasound examinations. A predictive model was further developed based on the entire cohort performance to determine the number of cases required to achieve a 95% success rate. Each anesthesiologist performed 30 ultrasound examinations (a total of 180 assessments), and three of the six participants achieved competence. The average number of cases required to achieve 90% and 95% success rates was estimated to be 24 and 33, respectively. With appropriate training and supervision, it is estimated that anesthesiologists will achieve a 95% success rate in bedside qualitative ultrasound assessment after performing approximately 33 examinations.

  14. Accuracy of ultrasound in prediction of rectosigmoid infiltration in epithelial ovarian cancer.

    PubMed

    Zikan, M; Fischerova, D; Semeradova, I; Slama, J; Dundr, P; Weinberger, V; Dusek, L; Cibula, D

    2017-10-01

    To examine prospectively the accuracy of ultrasound in predicting rectosigmoid tumor infiltration in patients with epithelial ovarian cancer. Patients referred for a suspicious pelvic mass between 2012 and 2014 were examined by ultrasound following the standard protocol for assessment of tumor infiltration. Of the 245 patients examined, 191 had proven ovarian cancer and underwent primary surgery and were included in the analysis. Patients with apparently benign or inoperable disease were excluded. Rectosigmoid infiltration was evaluated by histopathology or according to perioperative findings. Clinical, pathological and laboratory parameters were analyzed as factors potentially affecting the sensitivity and specificity of sonography. The sensitivity of ultrasound in detecting rectosigmoid infiltration in patients with ovarian cancer was 86.3%, with specificity of 95.8%, positive predictive value of 92.6%, negative predictive value of 91.9% and overall accuracy of 92.1%. Ultrasound is a highly accurate method for detecting rectosigmoid tumor infiltration in ovarian cancer patients, and thus, can be used for planning adequate management, including patient consultation, surgical team planning, suitable operating time and postoperative care. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  15. Ultrasound Imaging of DNA-Damage Effects in Live Cultured Cells and in Brain Tissue.

    PubMed

    Tadayyon, Hadi; Gangeh, Mehrdad J; Vlad, Roxana; Kolios, Michael C; Czarnota, Gregory J

    2017-01-01

    High-frequency ultrasound (>20 MHz) spectroscopy can be used to detect noninvasively DNA damage in cell samples in vitro, and in live tissue both ex vivo and in vivo. This chapter focuses on the former two aspects. Experimental evidence suggests that morphological changes that occur in cells undergoing apoptosis result in changes in frequency-dependent ultrasound backscatter. With advances in research, ultrasound spectroscopy is advancing the boundaries of fast, label-free, noninvasive DNA damage detection technology with potential use in personalized medicine and early therapy response monitoring. Depending on the desired resolution, parametric ultrasound images can be computed and displayed within minutes to hours after ultrasound examination for cell death.

  16. Ovary and vaginal epithelium dynamics during the estrous cycle in Dasyprocta prymnolopha Wagler, 1831: ultrasound and cytological examinations

    PubMed Central

    Carreiro, Artur N.; Diniz, João A. R. A.; Souza, Joyce G.; Araújo, Débora V. F.; Dias, Rômulo F. F.; Azerêdo, Liliane M. S.; Rocha, Ediane F.; La Salles, Ana Y. F.; Peña-Alfaro, Carlos E.; Carvalho, Maria A. M.; Illera, Maria J.

    2018-01-01

    The objective of the present study was to monitor and characterize morphological alterations in ovaries of agouti (Dasyprocta prymnolopha), reared in captivity, by using abdominal ultrasonography. All animals underwent daily vaginal cytological examination to identify the current cycle phase. For each phase of the estrous cycle, ultrasound examinations were carried out to identify and describe the morphology of both ovaries. Topographic parameters in an ultrasound window were established to locate the ovaries. The agouti estrous cycle lasted an average of 29.94 ± 6.77 days. During vaginal cytology examinations, all cell types were identified, and each phase of the estrous cycle was established by cell counts. No significant alterations were observed in the assessed ovarian morphometry measurements. In 75% of the animals examined, ovarian follicle presence was observed in the proestrus phase. PMID:29284211

  17. Diagnosis, treatment and follow-up of 25 patients with melamine-induced kidney stones complicated by acute obstructive renal failure in Beijing Children's Hospital.

    PubMed

    Sun, Qiang; Shen, Ying; Sun, Ning; Zhang, Gui Ju; Chen, Zhi; Fan, Jian Feng; Jia, Li Qun; Xiao, Hong Zhan; Li, Xu Ran; Puschner, Birgit

    2010-04-01

    A total of 25 Chinese patients aged 6 to 36 months hospitalised at Beijing Children's Hospital due to melamine-induced kidney stones complicated by acute obstructive renal failure in 2008 were included in a study in order to diagnose and treat these special cases more effectively. Feeding history, clinical presentation, ultrasound findings, treatments and effects were summarised. Twelve to seventeen months follow-up was reported also. Ultrasound examination showed that calculi were located at the kidney and ureters. Stones were composed of both uric acid and melamine in a molar ratio of 1.2:1 to 2.1:1. Treatments providing liquid plus alkalisation of urine proved to be effective in helping the patients pass the stones. Surgical intervention was needed in severe cases. Renal function returned to normal in all 25 patients after various durations of therapy. Sixty-eight percent of the patients expelled all of the calculi within 3 months, 90% in 6 months and 95% in 9 months, without sequelae till now. Melamine-contaminated milk formula can cause kidney stones in infants, which should be diagnosed by feeding history, clinical symptoms and ultrasound examination. Composition of the stones was not only of melamine but also uric acid. Providing liquid orally or intravenously plus alkalisation of urine proved to promote the removal of the stones. Follow-up of 12 to 17 months after discharge showed no sequelae.

  18. Sonography of iatrogenic pneumothorax in pediatric patients

    PubMed Central

    2013-01-01

    Pneumothorax is defined as the presence of air in the pleural cavity. The incidence of iatrogenic pneumothorax in the pediatric population is 0.3–0.48 in 1000 patients. A conventional chest X-ray, in some cases supplemented with chest computed tomography, is a typical imaging examination used to confirm the diagnosis of pneumothorax. Within the last years, the relevance of transthoracic lung ultrasound in the diagnostic process of this disease entity has greatly increased. This is confirmed by the opinion of a group of experts in ultrasound lung imaging in patients in a life-threatening condition, who strongly recommend a transthoracic ultrasound examination for the diagnosis of pneumothorax in such patients. These data constituted the basis for initiating the prospective studies on the application of this method in pneumothorax diagnosis in patients of pediatric hematology and oncology wards. Aim The aim of the study was to present the possibility of using the transthoracic lung ultrasound in the diagnostic process of pneumothorax in pediatric patients, with particular attention paid to its iatrogenic form. The article discusses sonographic criteria for pneumothorax diagnosis in pediatric patients, including the sensitivity and specificity of the method, in relation to conventional chest X-ray. Material and methods The prospective studies included a group of patients treated in the Clinic of Pediatrics, Pediatric Hematology, Oncology and Endocrinology of the Academic Clinical Centre (Medical University of Gdańsk, Poland) in whom a central venous catheter was placed in the subclavian veins. The studies lasted for one year – from 1 July 2011 to 30 June 2012. The examined group comprised 63 patients – 25 girls (39.7%) and 38 boys (60.3%) aged from 1 to 17. The analysis included the results of 115 ultrasound examinations conducted in this group. Results In t he examined group with suspected or diagnosed neoplasm, iatrogenic pneumothorax was identified in 4 out of 63 patients (6.3%). In all cases, it was a consequence of procedures connected with the introduction of a central catheter. In the examined material, the sensitivity, specificity and predictive values (positive and negative) of the transthoracic lung ultrasound equaled 100%. Conclusions The transthoracic ultrasound examination is a highly effective method in diagnosing iatrogenic pneumothorax in pediatric patients. However, to confirm this conclusion, multicenter studies, among considerably larger populations, are necessary. PMID:26675373

  19. Lung Ultrasound Pattern Is Normal during the Last Gestational Weeks: An Observational Pilot Study.

    PubMed

    Arbeid, Erik; Demi, Alessio; Brogi, Etrusca; Gori, Elisa; Giusto, Teresa; Soldati, Gino; Vetrugno, Luigi; Giunta, Francesco; Forfori, Francesco

    2017-01-01

    The normal lung ultrasound (US) pattern during a regular pregnancy has not been evaluated extensively in the current literature. Pregnancy-related changes in the respiratory tract affect maternal predisposition to several respiratory complications; consequently, it is important to differentiate between a physiologic pattern during pregnancy and a pathologic lung pattern, due to respiratory failure. The goal of our study was to assess the normal US lung pattern in women without known comorbidities in the last weeks of pregnancy. We conducted a prospective cross-sectional observational pilot study. Chest wall was examined in 8 areas, 1 scan for each area with women in supine position. One hundred fifty parturients were enrolled during the 36th-38th gestational weeks. None of the participants showed pleural effusion, pneumothorax or lung consolidation. None presented an interstitial syndrome US pattern. One hundred thirteen participants out of 150 (75%) showed A-lines in all the regions. The remaining 25% showed 1 or 2 B-lines in at least 3 regions. Only 2 participants showed 2 positive regions also. We found that, in the majority of the women examined, the lung US pattern matches the physiological pattern in non-pregnant patients. Lung US assessment is a feasible and a helpful diagnostic tool during pregnancy. © 2016 S. Karger AG, Basel.

  20. Discriminant validity study of Achilles enthesis ultrasound.

    PubMed

    Expósito Molinero, María Rosa; de Miguel Mendieta, Eugenio

    2016-01-01

    We want to know if the ultrasound examination of the Achilles tendon in spondyloarthritis is different compared to other rheumatic diseases. We studied 97 patients divided into five groups: rheumatoid arthritis, spondyloarthritis, gout, chondrocalcinosis and osteoarthritis, exploring six elementary lesions in 194 Achilles entheses examined. In our study the total index ultrasonographic Achilles is higher in spondyloarthritis with significant differences. The worst elementary spondyloarthritis lesions for discriminations against other pathologies were calcification. This study aims to demonstrate the discriminant validity of Achilles enthesitis observed by ultrasound in spondyloarthritis compared with other rheumatic diseases that may also have ultrasound abnormalities such enthesis level. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  1. The role of contrast-enhanced ultrasound in imaging carotid arterial diseases.

    PubMed

    Clevert, Dirk A; Paprottka, Philipp; Sommer, Wieland H; Helck, Andreas; Reiser, Maximilian F; Zengel, Pamela

    2013-06-01

    The standard of care for the initial diagnosis of carotid artery bifurcation diseases is carotid duplex ultrasound. Carotid abnormalities or difficult examinations may represent a diagnostic challenge in patients with clinical symptoms as well as in the follow-up after carotid endarterectomy, carotid artery stenting or other interventions. A promising new method in the diagnosis and follow-up of pathologic carotid diseases is contrast-enhanced ultrasound (CEUS). In comparison with magnetic resonance imaging or computed tomography, the contrast agents used for CEUS remain within the vascular space and hence can be used to study vascular disease and could provide additional information on carotid arterial diseases. This review describes the current carotid duplex ultrasound examination and compares the pathologic findings with CEUS. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Use of point-of-care ultrasound to evaluate for penile fracture in a child.

    PubMed

    Lam, Samuel H F

    2015-02-01

    Penile fracture is a urologic emergency requiring prompt surgical intervention. Ultrasound may help clarify the diagnosis in cases of uncertain history and physical examination. The author presents a case of suspected pediatric penile fracture, in which point-of-care ultrasound helped to rule out the condition and facilitated disposition of the patient.

  3. The Use of Ultrasound in Remediation of North American English /r/ in 2 Adolescents

    ERIC Educational Resources Information Center

    Adler-Bock, Marcy; Bernhardt, Barbara May; Gick, Bryan; Bacsfalvi, Penelope

    2007-01-01

    Purpose: Ultrasound can provide images of the tongue during speech production. The present study set out to examine the potential utility of ultrasound in remediation of North American English /r/. Method: The participants were 2 Canadian English-speaking adolescents who had not yet acquired /r/. The study included an initial period without…

  4. 3D ocular ultrasound using gaze tracking on the contralateral eye: a feasibility study.

    PubMed

    Afsham, Narges; Najafi, Mohammad; Abolmaesumi, Purang; Rohling, Robert

    2011-01-01

    A gaze-deviated examination of the eye with a 2D ultrasound transducer is a common and informative ophthalmic test; however, the complex task of the pose estimation of the ultrasound images relative to the eye affects 3D interpretation. To tackle this challenge, a novel system for 3D image reconstruction based on gaze tracking of the contralateral eye has been proposed. The gaze fixates on several target points and, for each fixation, the pose of the examined eye is inferred from the gaze tracking. A single camera system has been developed for pose estimation combined with subject-specific parameter identification. The ultrasound images are then transformed to the coordinate system of the examined eye to create a 3D volume. Accuracy of the proposed gaze tracking system and the pose estimation of the eye have been validated in a set of experiments. Overall system error, including pose estimation and calibration, are 3.12 mm and 4.68 degrees.

  5. Ultrasound biomicroscopic findings in hallerman-streiff syndrome.

    PubMed

    Sato, Miho; Terasaki, Hiroko; Amano, Emil; Okamoto, Yoko; Miyake, Yozo

    2002-01-01

    To demonstrate the usefulness of ultrasound biomicroscopy in detecting the morphological changes in the lens caused by the spontaneous absorption of lens material and to detect fundus abnormalities in a patient with Hallermann-Streiff syndrome. Case report of an infant diagnosed at the age of 2 months as having Hallermann-Streiff syndrome. Spontaneous lens absorption occurred during the course of follow-up and was detected only by ultrasound biomicroscopy after the patient was prepared for cataract surgery. The changes in the anterior chamber depth and lens shapes were documented by ultrasound biomicroscopy. Retinal folds that were barely observable by conventional ophthalmoscopy because of a dense cataract were clearly shown by ultrasound biomicroscopy. Ultrasound biomicroscopy can be used to examine the lenses of eyes that are not observable with conventional optical instruments. Ultrasound biomicroscopy can also be used to study the posterior segment of microphthalmic eyes. We recommend preoperative ultrasound biomicroscopy to prevent unnecessary anesthesia and surgical preparation.

  6. Ultrasound monitoring of shortwave diathermic treatment of gastrocnemius strain in a dog.

    PubMed

    Lideo, Luca; Milan, Roberto

    2013-10-24

    Rupture of the medial head of the gastrocnemius muscle occurs when the muscle is overstretched by dorsiflexion of the ankle with the knee in full extension. Muscle ultrasound (US) is a convenient diagnostic imaging technique for visualizing normal and pathological muscle tissue as it is a non-invasive real-time examination. Muscle US can also be used in the follow-up of patients with neuromuscular disorders. The aim of this paper is to describe US monitoring of the rehabilitation process in a dog undergoing diathermy treatment (TECAR) due to rupture of the proximal medial head of the gastrocnemius muscle and to show the changes in US appearance of the muscle before, during and after rehabilitation.

  7. Ultrasonographic diagnosis of early pregnancy in cattle using different ultrasound systems.

    PubMed

    Racewicz, Przemysław; Sickinger, Marlene; Włodarek, Jan; Jaśkowski, Jędrzej M

    2016-06-16

    To evaluate the efficiency of different ultrasound devices in achieving an early diagnosis of pregnancy in dairy herds. A total of 1976 Holstein Friesian cows and heifers were artificially inseminated (AI) according to the herd manager's regime. Pregnancy diagnostics were performed between day 26 and 35 after AI using six different types of ultrasound systems (linear vs. sector scanners). Manual rectal palpation between day 45 and 60 after AI was used as the gold standard for pregnancy diagnostics. Sensitivity (SENS), specificity (SPEC), positive (PPV) and negative predictive value (NPV) and diagnostic accuracy (ACC) of the diagnostic measures were determined. Average SENS was 82% (range 67.7-95.2%) with a mean SPEC of 73% (range 50.0-81.0%). ACC was 78.2% with a minimum of 64.6% and a maximum of 89.4%, depending on the ultrasound system. The PPV (ratio of the number of pregnant cows with a positive examination result to the number of cows actually pregnant) was 80.8% (range 59.1-88.1%), whereas the NPV (defined as the ratio of the number of cows correctly diagnosed negative to the number of cows actually open) was 74.4% (72.3-91.9%). Significant differences for these parameters were found depending on the ultrasound system used (p ≤ 0.01; Cramer's V. = 0.14). Regardless of the ultrasound device used, early pregnancy diagnostics between day 26 and 35 show a moderate diagnostic efficiency. Comparing the accuracy of the different devices, there may be a significant influence of type and technical parameters. Even though ultrasound systems with mechanical sector probes are not as convenient to use as systems with linear probes, according to this study, sector scanners are a reasonable alternative.

  8. Degradation of Acid Blue 25 in aqueous media using 1700kHz ultrasonic irradiation: ultrasound/Fe(II) and ultrasound/H(2)O(2) combinations.

    PubMed

    Ghodbane, Houria; Hamdaoui, Oualid

    2009-06-01

    In this work, the sonolytic degradation of an anthraquinonic dye, C.I. Acid Blue 25 (AB25), in aqueous phase using high frequency ultrasound waves (1700kHz) for an acoustic power of 14W was investigated. The sonochemical efficiency of the reactor was evaluated by potassium iodide dosimeter, Fricke reaction and hydrogen peroxide production yield. The three investigated methods clearly show the production of oxidizing species during sonication and well reflect the sonochemical effects of high frequency ultrasonic irradiation. The effect of operational conditions such as the initial AB25 concentration, solution temperature and pH on the degradation of AB25 was studied. Additionally, the influence of addition of salts on the degradation of dye was examined. The rate of AB25 degradation was dependent on initial dye concentration, pH and temperature. Addition of salts increased the degradation of dye. Experiments conducted using distilled and natural waters demonstrated that the degradation was more efficient in the natural water compared to distilled water. To increase the efficiency of AB25 degradation, experiments combining ultrasound with Fe(II) or H(2)O(2) were conducted. Fe(II) induced the dissociation of ultrasonically produced hydrogen peroxide, leading to additional OH radicals which enhance the degradation of dye. The combination of ultrasound with hydrogen peroxide looks to be a promising option to increase the generation of free radicals. The concentration of hydrogen peroxide plays a crucial role in deciding the extent of enhancement obtained for the combined process. The results of the present work indicate that ultrasound/H(2)O(2) and ultrasound/Fe(II) processes are efficient for the degradation of AB25 in aqueous solutions by high frequency ultrasonic irradiation.

  9. MRI-guided targeted blood-brain barrier disruption with focused ultrasound: histological findings in rabbits.

    PubMed

    McDannold, Nathan; Vykhodtseva, Natalia; Raymond, Scott; Jolesz, Ferenc A; Hynynen, Kullervo

    2005-11-01

    Focused ultrasound offers a method to disrupt the blood-brain barrier (BBB) noninvasively and reversibly at targeted locations. The purpose of this study was to test the safety of this method by searching for ischemia and apoptosis in areas with BBB disruption induced by pulsed ultrasound in the presence of preformed gas bubbles and by looking for delayed effects up to one month after sonication. Pulsed ultrasound exposures (sonications) were performed in the brains of 24 rabbits under monitoring by magnetic resonance imaging (MRI) (ultrasound: frequency = 1.63 MHz, burst length = 100 ms, PRF = 1 Hz, duration = 20 s, pressure amplitude 0.7 to 1.0 MPa). Before sonication, an ultrasound contrast agent (Optison, GE Healthcare, Milwaukee, WI, USA) was injected IV. BBB disruption was confirmed with contrast-enhanced MR images. Whole brain histologic examination was performed using haematoxylin and eosin staining for general histology, vanadium acid fuchsin-toluidine blue staining for ischemic neurons and TUNEL staining for apoptosis. The main effects observed were tiny regions of extravasated red blood cells scattered around the sonicated locations, indicating affected capillaries. Despite these vasculature effects, only a few cells in some of the sonicated areas showed evidence for apoptosis or ischemia. No ischemic or apoptotic regions were detected that would indicate a compromised blood supply was induced by the sonications. No delayed effects were observed either by MRI or histology up to 4 wk after sonication. Ultrasound-induced BBB disruption is possible without inducing substantial vascular damage that would result in ischemic or apoptotic death to neurons. These findings indicate that this method is safe for targeted drug delivery, at least when compared with the currently available invasive methods.

  10. Pulsed ultrasounds accelerate healing of rib fractures in an experimental animal model: an effective new thoracic therapy?

    PubMed

    Santana-Rodríguez, Norberto; Clavo, Bernardino; Fernández-Pérez, Leandro; Rivero, José C; Travieso, María M; Fiuza, María D; Villar, Jesús; García-Castellano, José M; Hernández-Pérez, Octavio; Déniz, Antonio

    2011-05-01

    Rib fractures are a frequent traumatic injury associated with a relatively high morbidity. Currently, the treatment of rib fractures is symptomatic. Since it has been reported that pulsed ultrasounds accelerates repair of limb fractures, we hypothesized that the application of pulsed ultrasounds will modify the course of healing in an animal model of rib fracture. We studied 136 male Sprague-Dawley rats. Animals were randomly assigned to different groups of doses (none, 50, 100, and 250 mW/cm(2) of intensity for 3 minutes per day) and durations (2, 10, 20, and 28 days) of treatment with pulsed ultrasounds. In every subgroup, we analyzed radiologic and histologic changes in the bone callus. In addition, we examined changes in gene expression of relevant genes involved in wound repair in both control and treated animals. Histologic and radiologic consolidation was significantly increased by pulsed ultrasound treatment when applied for more than 10 days. The application of 50 mW/cm(2) was the most effective dose. Only the 100 and 250 mW/cm(2) doses were able to significantly increase messenger RNA expression of insulin-like growth factor 1, suppressor of cytokine signaling-2 and -3, and vascular endothelial growth factor and decrease monocyte chemoattractant protein-1 and collagen type II-alpha 1. Our findings indicate that pulsed ultrasound accelerates the consolidation of rib fractures. This study is the first to show that pulsed ultrasound promotes the healing of rib fractures. From a translational point of view, this easy, cheap technique could serve as an effective new therapeutic modality in patients with rib fractures. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  11. Hyperemia in plantar fasciitis determined by power Doppler ultrasound.

    PubMed

    McMillan, Andrew M; Landorf, Karl B; Gregg, Julie M; De Luca, Jason; Cotchett, Matthew P; Menz, Hylton B

    2013-12-01

    Cross-sectional observational study. To investigate the presence of soft tissue hyperemia in plantar fasciitis with power Doppler ultrasound. Localized hyperemia is an established feature of tendinopathy, suggesting that neurovascular in-growth may contribute to tendon-associated pain in some patients. The presence of abnormal soft tissue vascularity can be assessed with Doppler ultrasound, and a positive finding can assist with targeted treatment plans. However, very little is known regarding the presence of hyperemia in plantar fasciitis and the ability of routine Doppler ultrasound to identify vascular in-growth in the plantar fascia near its proximal insertion. This observational study included 30 participants with plantar fasciitis unrelated to systemic disease and 30 age- and sex-matched controls. Ultrasound examination was performed with a 13- to 5-MHz linear transducer, and power Doppler images were assessed by 2 blinded investigators. Hyperemia of the plantar fascia was present in 8 of 30 participants with plantar fasciitis and in 2 of 30 controls. The between-group difference for hyperemia, using a 4-point scale, was statistically significant, with participants with plantar fasciitis showing increased Doppler ultrasound signal compared to controls (Mann-Whitney U, P = .03). However, the majority of participants with plantar fasciitis with evidence of hyperemia demonstrated very mild color changes, and only 3 were found to have moderate or marked hyperemia. Mild hyperemia can occur with plantar fasciitis, but most individuals will not exhibit greater soft tissue vascularity when assessed with routine Doppler ultrasound. Clinicians treating plantar fasciitis should not consider a positive Doppler signal as essential for diagnosis of the condition but, rather, as a feature that may help to refine the treatment plan for an individual patient.

  12. Endometriosis on the uterosacral ligament: a marker of ureteral involvement.

    PubMed

    Lima, Raquel; Abdalla-Ribeiro, Helizabet; Nicola, Ana Luisa; Eras, Aline; Lobao, Anna; Ribeiro, Paulo Ayroza

    2017-06-01

    To evaluate the association between ultrasound measurements of endometriosis nodules on the uterosacral ligament (USL) and the risk of ureteral involvement, as well as to assess whether associations with other ultrasound variables increase the sensitivity and specificity of the diagnosis of ureteral endometriosis. Cross-sectional, observational study. University hospital. Four hundred sixty-three women with deep infiltrating endometriosis (DIE). Patients diagnosed with DIE underwent transvaginal ultrasound endometriosis mapping before laparoscopic surgery for full excision of endometriotic lesions. Preoperative ultrasound evaluation, intra- and postoperative assessment, and anatomopathologic confirmation. Of the 463 patients who participated in the study, 111 (23.97%) presented with endometriosis nodules with USL involvement on ultrasound examination conducted by a single radiologist. Receiver operating characteristic curve analysis showed that the size of the USL nodule had a statistically significant association with ipsilateral ureteral involvement. After multivariate logistic regression, the variables reduction in ovarian mobility, ureteral changes on the right side, size of the USL nodule, and presence of endometrioma on the left side were significantly associated with a ureteral endometriosis nodule. However, the combined result for the variables cited was worse than the diagnostic analysis using only the size of the USL nodule. Uterosacral ligament nodules with ultrasound measurements of 1.75 cm and 1.95 cm on the right and left sides, respectively, significantly increase the risk of ureteral involvement. Even with the association of other ultrasound variables, there was no improvement in sensitivity. Therefore, USL nodule size is a key measure for therapeutic planning and consent of the patient. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  13. Ultrasound/microwave-assisted solid-liquid-solid dispersive extraction with high-performance liquid chromatography coupled to tandem mass spectrometry for the determination of neonicotinoid insecticides in Dendrobium officinale.

    PubMed

    Zheng, Shuilian; Wu, Huizhen; Li, Zuguang; Wang, Jianmei; Zhang, Hu; Qian, Mingrong

    2015-01-01

    A one-step ultrasound/microwave-assisted solid-liquid-solid dispersive extraction procedure was used for the simultaneous determination of eight neonicotinoids (dinotefuran, nitenpyram, thiamethoxam, clothianidin, imidacloprid, acetamiprid, thiacloprid, imidaclothiz) in dried Dendrobium officinale by liquid chromatography combined with electrospray ionization triple quadrupole tandem mass spectrometry in multiple reaction monitoring mode. The samples were quickly extracted by acetonitrile and cleaned up by the mixed dispersing sorbents including primary secondary amine, C18 , and carbon-GCB. Parameters that could influence the ultrasound/microwave-assisted extraction efficiency such as microwave irradiation power, ultrasound irradiation power, temperature, and solvent were investigated. Recovery studies were performing well (70.4-113.7%) at three examined spiking levels (10, 50, and 100 μg/kg). Meanwhile, the limits of quantification for the neonicotinoids ranged from 0.87 to 1.92 μg/kg. The method showed good linearity in the concentration range of 1-100 μg/L with correlation coefficients >0.99. This quick and useful analytical method could provide a basis for monitoring neonicotinoid insecticide residues in herbs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Comparison of Two Different Ultrasound Devices Using Strain Elastography Technology in the Diagnosis of Breast Lesions Related to the Histologic Results.

    PubMed

    Farrokh, André; Schaefer, Fritz; Degenhardt, Friedrich; Maass, Nicolai

    2018-05-01

    This study was conducted to provide evidence that elastograms of two different devices and different manufacturers using the same technical approach provide the same diagnoses. A total of 110 breast lesions were prospectively analysed by two experts in ultrasound, using the strain elastography function from two different manufacturers (Hitachi HI-RTE, Hitachi Medical Systems, Wiesbaden, Germany; and Siemens eSie Touch, Siemens Medical Systems, Erlangen, Germany). Results were compared with the histopathologic results. Applying the Bowker test of symmetry, no statistically significant difference between the two elastography functions of these two devices was found (p = 0.120). The Cohen's kappa of k = 0.591 showed moderate strength of agreement between the two elastograms. The two examiners yielded moderate strength of agreement analysing the elastograms (Hitachi HI-RTE, k = 0.478; Siemens eSie Touch, k = 0.441). In conclusion, evidence is provided that elastograms of the same lesion generated by two different ultrasound devices equipped with a strain elastography function do not significantly differ. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  15. Neuronal encoding of ultrasonic sound by a fish.

    PubMed

    Plachta, Dennis T T; Song, Jiakun; Halvorsen, Michele B; Popper, Arthur N

    2004-06-01

    Many species of odontocete cetaceans (toothed whales) use high-frequency clicks (60-170 kHz) to identify objects in their environment, including potential prey. Behavioral studies have shown that American shad, Alosa sapidissima, can detect ultrasonic signals similar to those of odontocetes that are potentially their predators. American shad also show strong escape behavior in response to ultrasonic pulses between 70 and 110 kHz and can determine the location of the sound source at least in the horizontal plane. The present study examines physiological aspects of ultrasound detection by American shad and provides the first insights into the neural encoding of ultrasound signals in any nonmammalian vertebrate. The recordings were obtained by penetration through the cerebellar surface. All but two units responded exclusively to ultrasound. Ultrasound-sensitive units did not phase-couple to any stimulus frequency. Some units resembled the response of constant latency neurons found in the ventral nucleus of the lateral lemniscus of bats. We suggest that ultrasonic and sonic signals are processed along different pathways in Alosa. The ultrasonic pathway in Alosa appears to be a feature detector that is likely to be adapted (e.g., frequency, intensity) to odontocete echolocation signals.

  16. A case of Legionella pneumophila evaluated with CT and ultrasound.

    PubMed

    D'Angelo, Alessio; De Simone, Chiara; Pagnottella, Marco; Rossi, Stefano; Pepe, Raffaele; Ruggieri, Giacomo; Cocco, Giulio; Schiavone, Cosima

    2017-09-01

    A 36-year-old man was admitted to the emergency department of "SS Annunziata" hospital in Chieti complaining of a sharp chest pain arisen some hours before admission. On examination, the patient looked sweaty; his vital signs showed tachycardia and augmented breath rate; sinus tachycardia and normal ventricular repolarization were observed on ECG, and no abnormalities were observed in the echoscan of the hearth. According to the clinical and electrocardiographic findings, and to previous episode of DVT in anamnesis, a thorax CT scan was performed in order to rule out pulmonary embolism. It showed an "area of parenchymal consolidation involving almost all the left lower lobe with patent bronchial structures"; given the patient's CURB 65 score, he was then admitted to the pneumology ward where empiric treatment with levofloxacin (750 mg PO once daily) was initiated. Thoracic ultrasound was performed using a multifrequency convex transducer, and the posterior left area was examined through intercostal approach, placing the patient in a sitting position. A subpleural patchy hypoechoic lesion with irregular boundaries was detected; the maximum diameter was 11 cm, and the multiple hyperechoic spots inside it (elsewhere defined as "air bronchogram") showed no Doppler signal. Given the positive result of the Legionella urinary antigen test, antibiotic treatment was switched to Levofloxacin 1000 mg PO once daily and Claritromicin 500 mg PO twice daily. After 3 days, his clinical conditions improved dramatically. Ultrasound performed after 5 days from the diagnosis showed decreased dimensions of the lesion previously identified (maximum diameter 8.25 cm) and a marked reduction of the hyperechoic spots in it. The patient was discharged in good clinical conditions, and both thorax CT scan obtained after 1 and 4 months from the diagnosis showed radiological resolution of the parenchymal consolidation. The key to ultrasound visualization of pneumonia is its contact with the pleural surface (86-98% in cases of CAP) and the relative loss of aeration of the portion involved by the infection and a concomitant increase in the fluid content. A paradigmatic US image for parenchymal inflammatory infiltrate has not been established yet; anyway, some typical findings, when combined with the clinical features, can confirm the diagnostic hypothesis.

  17. Correlation between prenatal ultrasound and postmortem findings in 1029 fetuses following termination of pregnancy.

    PubMed

    Struksnaes, C; Blaas, H-G K; Eik-Nes, S H; Vogt, C

    2016-08-01

    A prenatal ultrasound examination and a postmortem examination provide the basis for correct diagnosis in fetuses terminated due to congenital anomalies. The aim of this study was to correlate fetal anomalies detected by ultrasound examination with those identified at autopsy following termination of pregnancy (TOP) over a 30-year period, and to evaluate the correlation between findings at different gestational ages and assess these trends over time. The study group consisted of 1029 TOPs performed over a 30-year period, from 1985 to 2014. The gestational age ranged between 11 and 33 weeks. Prenatal ultrasound examinations were performed at the National Center for Fetal Medicine, St Olavs Hospital, Trondheim, Norway. Autopsies were performed at the Department of Pathology and Medical Genetics at the same hospital or a collaborating hospital. There was full agreement between ultrasound and autopsy findings in 88.1% (907/1029) of TOPs, and the main diagnosis was correct in 97.9% (1007/1029). When comparing the 15-year period of 2000-2014 with that of 1985-1999, the difference in the rates of full agreement and agreement in the main diagnosis was statistically significant. In 1.3% (13/1029) of cases, ultrasound findings were not confirmed at autopsy. There were no false-positive diagnoses leading to TOP. Throughout the 30-year period, there was an increase in early TOPs, whereas late TOPs declined. Our study demonstrates that there is a clear correlation between ultrasound and autopsy findings, which is continuously improving. Despite this high correlation, there is reason to continue the practice of validation to ensure the safety of the diagnostic process leading to TOP. The trend towards an earlier termination emphasizes the necessity of such a practice. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  18. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  19. Ultrasound imaging diagnostics: healthcare risks for urologists.

    PubMed

    Martino, Tilde; Massaro, Tommaso; Martino, Paolo; Martino, Pasquale

    2010-12-01

    The objectives of this study are: 1) assessing if Ultrasound (US) used during US scans can represent a risk for the healthcare of urologists; 2) verifying the frequency of Carpal Tunnel Syndrome (CTS) symptoms and musculoskeletal disorders (MSD), trying to assess the possible correlation with job load and US scanning procedures; 3) assessing the role of individual factors like age, gender and physical activity in determining such disorders. A group of 35 voluntary urologists carrying out ultrasound scans were selected: 13 were working for the 1 degrees Teaching Hospital Urology, 11 for the 2 degrees Teaching Hospital Urology, 2 for the Hospitalization Urology of the Policlinico of Bari and 9 for Urology of Public Corporation Di Venere of Bari. A questionnaire, divided in two parts, was administered to the sample: the first aimed at collecting demographic data and at describing the operators' workload and the second focused on the possible presence of CTS and MSD symptoms. 32 urologists over 35 performed more than 5 scans per week and more than 5 scans per day. On average the specialists were carrying out this activity since 18 years wheras for post-graduate students, this time was about 4 years. Twenty-six subjects (74%) showed no symptoms, 8 subjects (23%) showed from 1 to 4 symptoms which can be associated to the presence of CTS; only one subject presents more than 5 symptoms. As regards MSD, 6 urologists (17%) did not present disorders, 24 subjects (69%) showed from 1 to 4 symptoms and 5 subjects (14%) presented more than 5 symptoms. The use of US scan examination is completely safe both for the healthcare of the patients and the operator. For what concerns healthcare risks, it is highly recommended to adopt a correct posture when performing the examination and to use the provided chair.

  20. Measuring the volume of uterine fibroids using 2- and 3-dimensional ultrasound and comparison with histopathology.

    PubMed

    Zivković, Nikica; Zivković, Kreiimir; Despot, Albert; Paić, Josip; Zelić, Ana

    2012-12-01

    The aim of this study was clinical testing of the reliability and usability of three-dimensional (3D) and two-dimensional (2D) ultrasound (US) technology. The ultimate aim and purpose of this study was to establish ultrasound methods, standards and protocols for determining the volume of any gynecologic organ or tumor. The study included 31 women in reproductive age and postmenopause. All patients were examined with a RIC 5-9 3D-endovaginal probe (4.3-7.5 MHz) on a Voluson 730 Pro ultrasound device. The volume of myomas was measured by using the existing 2D and 3D ultrasound methods on the above mentioned device. All patients underwent myomectomy or hysterectomy due to clinically and ultrasonographically diagnosed uterine myomas indicating operative intervention. After the operation, the pathologist determined the volume of removed myomas by measuring them in a gauge bowl containing water, i.e. using Archimedes' principle (lift), serving as the control group with histopathologic diagnosis. A total of 155 myoma volumes were processed on 2D display, 31 myoma volumes were preoperatively measured on 3D display and 31 myoma volumes were measured by the pathologist. The values of US measurements for each US method were expressed as mean value of all measurements of myoma volumes. Statistical processing of the results and Student's t-test for independent samples revealed that the 2nd examined US method (measuring of myoma by using an ellipse and the longer tumor diameter) and 4th examined US method (measuring of myoma by using the longer and shorter tumor diameters together with establishing their mean values) in 2D US technique, as well as the 6th examined US method in 3D US technique showed no significant measurement differences in comparison with control measurement in a gauge bowl containing water (p < 0.05), indicating acceptability of the US methods for verifying tumor volumes. The standard error in determining the volume of myomas by the above US methods varied between 15% and 25%, so it is concluded that these three methods can be used in clinical practice to determine tumor volumes, in this case uterine myomas. The 3D MultiPlane method proved to be the most reliable method of determining the volume of uterine myomas.

  1. Mistakes in ultrasound examination of salivary glands

    PubMed Central

    Jakubowski, Wiesław

    2016-01-01

    Ultrasonography is the first imaging method applied in the case of diseases of the salivary glands. The article discusses basic mistakes that can be made during an ultrasound examination of these structures. The reasons for these mistakes may be examiner-dependent or may be beyond their control. The latter may include, inter alia, difficult conditions during examination (technical or patient-related), similarity of ultrasound images in different diseases, the lack of clinical and laboratory data as well as the lack of results of other examinations, their insufficient number or incorrectness. Doctor-related mistakes include: the lack of knowledge of normal anatomy, characteristics of ultrasound images in various salivary gland diseases and statistical incidence of diseases, but also attaching excessive importance to such statistical data. The complex anatomical structures of the floor of the oral cavity may be mistaken for benign or malignant tumors. Fragments of correct anatomical structures (bones, arterial wall fibrosis, air bubbles in the mouth) can be wrongly interpreted as deposits in the salivary gland or in its excretory duct. Correct lymph nodes in the parotid glands may be treated as pathologic structures. Lesions not being a simple cyst, e.g. lymphoma, benign or malignant tumors of the salivary glands or metastatic lymph nodes, can be mistaken for one. The image of disseminated focal changes, both anechoic and solid, is not pathognomonic for specific diseases in the salivary glands. However, in part, it occurs typically and requires an extended differential diagnosis. Small focal changes and infiltrative lesions pose a diagnostic problem because their etiology cannot be safely suggested on the basis of an ultrasound examination itself. The safest approach is to refer patients with abnormal focal changes for an ultrasoundguided fine-needle aspiration biopsy. PMID:27446603

  2. [Ultrasonography of the prostate gland : From B‑image through multiparametric ultrasound to targeted biopsy].

    PubMed

    Steinkohl, F; Luger, A; Bektic, J; Aigner, F

    2017-08-01

    Prostate cancer is the most frequent cancer in men. The diagnosis is normally achieved by a systematic prostate biopsy; however, this is a randomized approach by which a substantial number of significant carcinomas go undetected. For this reason, in recent years imaging techniques have been continuously developed, which enable visualization and therefore targeted biopsies. The use of systematic biopsies is a standard procedure for the detection of prostate cancer. The quality of biopsies can be increased if the prostate is examined for the presence of suspected cancerous alterations during the biopsy. This can be carried out using multiparametric transrectral ultrasound. Multiparametric ultrasound within the framework of a targeted biopsy increases the detection rate of significant prostate carcinomas with a simultaneous decrease in detection of insignificant carcinomas; however, the diagnostic reliability and the evidence level of multiparametric transrectal ultrasound are not yet sufficiently high to be able to replace a systematic biopsy. In the hands of a well-trained examiner multiparametric transrectal ultrasound represents a good method for detection of prostate carcinomas. With the progression in technical developments of ultrasound technology, the detection rate will presumably be further increased.

  3. Use of the Combined First-Trimester Screen in High- and Low-Risk Patient Populations After Introduction of Noninvasive Prenatal Testing.

    PubMed

    Larion, Sebastian; Warsof, Steven L; Romary, Letty; Mlynarczyk, Margaret; Peleg, David; Abuhamad, Alfred Z

    2015-08-01

    To report changes in the use of the combined first-trimester screen (FTS) in patients classified as high and low risk for fetal aneuploidy, including after introduction of noninvasive prenatal testing (NIPT). A prospectively collected database was reviewed to investigate changes in FTS use before and after American College of Obstetricians and Gynecologists (ACOG) Practice Bulletin No. 77 (Obstet Gynecol 2007; 109:217-227), which recommended that all patients be offered aneuploidy screening, and after NIPT introduction. High-risk patients were classified as 35 years or older at the estimated time of delivery or those with an abnormal prior screen, abnormal ultrasound findings, or family history of aneuploidy. Data were normalized per 100 morphologic ultrasound examinations to account for changes in patient number over time. Statistical significance was defined as P < .05. A total of 10,125 FTSs were recorded during the 88-month study period, including 2962 in high-risk patients and 7163 in low-risk patients. The total number of FTSs performed per 100 morphologic ultrasound examinations significantly increased after ACOG Practice Bulletin No. 77 and significantly decreased after NIPT introduction. In high-risk patients, the total number of FTSs performed per 100 morphologic ultrasound examinations significantly increased after ACOG Practice Bulletin No. 77 but significantly decreased after NIPT introduction. In contrast, in low-risk patients, the total number of FTSs performed per 100 morphologic ultrasound examinations significantly increased after ACOG Practice Bulletin No.77 but was not statistically different after NIPT introduction. American College of Obstetricians and Gynecologists Practice Bulletin No. 77 significantly increased patient use of FTS. The introduction of NIPT significantly decreased FTS use in the high-risk population but not in the low-risk population. © 2015 by the American Institute of Ultrasound in Medicine.

  4. Ultrasound Imaging of the Musculoskeletal System.

    PubMed

    Cook, Cristi R

    2016-05-01

    Musculoskeletal ultrasound is a rapidly growing field within veterinary medicine. Ultrasound for musculoskeletal disorders has been commonly used in equine and human medicine and is becoming more commonly performed in small animal patients due to the increase in the recognition of soft tissue injuries. Ultrasound is widely available, cost-effective, but technically difficult to learn. Advantages of musculoskeletal ultrasound are the opposite limb is commonly used for comparison to evaluate symmetry of the tendinous structures and the ease of repeat examinations to assess healing. The article discusses the major areas of shoulder, stifle, iliopsoas, gastrocnemius, and musculoskeletal basics. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Mapping cardiac fiber orientations from high-resolution DTI to high-frequency 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Qin, Xulei; Wang, Silun; Shen, Ming; Zhang, Xiaodong; Wagner, Mary B.; Fei, Baowei

    2014-03-01

    The orientation of cardiac fibers affects the anatomical, mechanical, and electrophysiological properties of the heart. Although echocardiography is the most common imaging modality in clinical cardiac examination, it can only provide the cardiac geometry or motion information without cardiac fiber orientations. If the patient's cardiac fiber orientations can be mapped to his/her echocardiography images in clinical examinations, it may provide quantitative measures for diagnosis, personalized modeling, and image-guided cardiac therapies. Therefore, this project addresses the feasibility of mapping personalized cardiac fiber orientations to three-dimensional (3D) ultrasound image volumes. First, the geometry of the heart extracted from the MRI is translated to 3D ultrasound by rigid and deformable registration. Deformation fields between both geometries from MRI and ultrasound are obtained after registration. Three different deformable registration methods were utilized for the MRI-ultrasound registration. Finally, the cardiac fiber orientations imaged by DTI are mapped to ultrasound volumes based on the extracted deformation fields. Moreover, this study also demonstrated the ability to simulate electricity activations during the cardiac resynchronization therapy (CRT) process. The proposed method has been validated in two rat hearts and three canine hearts. After MRI/ultrasound image registration, the Dice similarity scores were more than 90% and the corresponding target errors were less than 0.25 mm. This proposed approach can provide cardiac fiber orientations to ultrasound images and can have a variety of potential applications in cardiac imaging.

  6. Point-of-Care Ultrasound for Pulmonary Concerns in Remote Spaceflight Triage Environments.

    PubMed

    Johansen, Benjamin D; Blue, Rebecca S; Castleberry, Tarah L; Antonsen, Erik L; Vanderploeg, James M

    2018-02-01

    With the development of the commercial space industry, growing numbers of spaceflight participants will engage in activities with a risk for pulmonary injuries, including pneumothorax, ebullism, and decompression sickness, as well as other concomitant trauma. Medical triage capabilities for mishaps involving pulmonary conditions have not been systematically reviewed. Recent studies have advocated the use of point-of-care ultrasound to screen for lung injury or illness. The operational utility of portable ultrasound systems in disaster relief and other austere settings may be relevant to commercial spaceflight. A systematic review of published literature was conducted concerning the use of point-of-care pulmonary ultrasound techniques in austere environments, including suggested examination protocols for triage and diagnosis. Recent studies support the utility of pulmonary ultrasound examinations when performed by skilled operators, and comparability of the results to computed tomography and chest radiography for certain conditions, with important implications for trauma management in austere environments. Pulmonary injury and illness are among the potential health risks facing spaceflight participants. Implementation of point-of-care ultrasound protocols could aid in the rapid diagnosis, triage, and treatment of such conditions. Though operator-dependent, ultrasound, with proper training, experience, and equipment, could be a valuable tool in the hands of a first responder supporting remote spaceflight operations.Johansen BD, Blue RS, Castleberry TL, Antonsen EL, Vanderploeg JM. Point-of-care ultrasound for pulmonary concerns in remote spaceflight triage environments. Aerosp Med Hum Perform. 2018; 89(2):122-129.

  7. Can a limited double reading/second opinion of initially recalled breast ultrasound screening examinations improve radiologists' performances?

    NASA Astrophysics Data System (ADS)

    Gur, David; Harnist, Kimberly; Gizienski, Terri-Ann; Zuley, Margarita; Hakim, Christiane; Lu, Amy; Sumkin, Jules; Abrams, Gordon; Ganott, Marie A.; Kelly, Amy E.; Tyma, Cathy S.; Chang, Thomas; BÓ§hm-Vélez, Marcella; Sobolewski, Robin

    2018-03-01

    Interpretations of breast ultrasound screening examinations result in high recall rates and large inter-radiologist variability, frequently leading to "conservative" recommendations. Double reading of all breast ultrasound screening examinations is cost prohibitive, but double reading of only "initially recalled" cases may prove efficacious. We assessed changes in recommendations, if any, by providing a consensus second opinion in a limited subset of examinations initially recommended for recall. We performed a retrospective reader study with 197 ultrasound examinations (97 not recalled and 100 recalled clinically). First, we generated a consensus "second opinion" consisting of the majority vote of three independent readings of each case by experienced ultrasound interpreters. During the reader study that followed, if the reader recommended a "recall" and the "consensus second opinion" did not, a message to that effect was displayed and the reader was asked to re-review the exam and re-assess if, knowing the second opinion, a re-rating of the case was warranted. We compared performance levels pre- and post- the second opinion. The second opinion resulted in "no recall" recommendations of 141 cases in the entire set, including four cancer cases missed by all three readers. On average, radiologists received "warning" messages in 30 cases (range 15-50), or in 15% of cases. Rating changes (downgrades to no recall) occurred in 36 of these cases. These changes resulted in a possible recall rate reduction of 28% in prompted cases or 14% overall recall reduction, while increasing the false negative rate by only one case missed by 2 readers ( 1%).

  8. Sonography of suspected acute appendicitis in children: Evaluation of the progress in performance of senior residents.

    PubMed

    Gerbier, Pierre; Binet, Aurélien; Etancelin, Mathilde; Barteau, Emmanuel; Auger, Marie; Morales, Luciano; Bertrand, Philippe; Sirinelli, Dominique; Morel, Baptiste

    2018-04-01

    The objective of this study was to evaluate the progress in performance of senior residents in diagnosing acute appendicitis. Results were collected and compared of ultrasound examinations performed for suspected acute appendicitis by three senior residents and two faculty members over a six-month period in a university hospital setting. A grid with the sonographic findings was completed separately by the residents and the faculty members immediately after each examination. The duration of each examination was reported. The final ultrasound diagnosis was compared to the surgical and pathological results and to the clinical follow-up. The residents and faculty members performed 171 consecutive ultrasound examinations including 49 children with acute appendicitis and 122 with normal appendices. The accuracy of the diagnosis by the residents was 96%, and was similar to that of the faculty members (kappa=0.90) over the six months. The duration of the resident ultrasound examinations was significantly shorter during the second three-month period (p=0.01). No significant differences in diagnostic accuracy were demonstrated by the residents between the first and second three-month periods (p=0.06). The residents performed well when using sonography to diagnose acute appendicitis in children, and were faster during the second three-month period. I. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Diagnostic performance of multi-organ ultrasound with pocket-sized device in the management of acute dyspnea.

    PubMed

    Sforza, Alfonso; Mancusi, Costantino; Carlino, Maria Viviana; Buonauro, Agostino; Barozzi, Marco; Romano, Giuseppe; Serra, Sossio; de Simone, Giovanni

    2017-06-19

    The availability of ultra-miniaturized pocket ultrasound devices (PUD) adds diagnostic power to the clinical examination. Information on accuracy of ultrasound with handheld units in immediate differential diagnosis in emergency department (ED) is poor. The aim of this study is to test the usefulness and accuracy of lung ultrasound (LUS) alone or combined with ultrasound of the heart and inferior vena cava (IVC) using a PUD for the differential diagnosis of acute dyspnea (AD). We included 68 patients presenting to the ED of "Maurizio Bufalini" Hospital in Cesena (Italy) for AD. All patients underwent integrated ultrasound examination (IUE) of lung-heart-IVC, using PUD. The series was divided into patients with dyspnea of cardiac or non-cardiac origin. We used 2 × 2 contingency tables to analyze sensitivity, specificity, positive predictive value and negative predictive value of the three ultrasonic methods and their various combinations for the diagnosis of cardiogenic dyspnea (CD), comparing with the final diagnosis made by an independent emergency physician. LUS alone exhibited a good sensitivity (92.6%) and specificity (80.5%). The highest accuracy (90%) for the diagnosis of CD was obtained with the combination of LUS and one of the other two methods (heart or IVC). The IUE with PUD is a useful extension of the clinical examination, can be readily available at the bedside or in ambulance, requires few minutes and has a reliable diagnostic discriminant ability in the setting of AD.

  10. Synovial haemangioma of the knee joint: an unusual cause of knee pain in a 14-month old girl.

    PubMed

    Wen, D W; Tan, T J; Rasheed, S

    2016-06-01

    We report a histologically proven case of synovial haemangioma of the knee in a 14-month old girl who presented to the emergency department with an acute 1-day history of refusing to weight-bear on the right leg and a preceding 3-week history of a right knee lump. Physical examination revealed a non-tender, soft lump over the lateral infrapatellar region. Radiographs revealed a poorly defined soft tissue density over the infrapatellar fat pad and a suprapatellar joint effusion. Ultrasound was used to confirm the presence of a vascular soft tissue mass compatible with a synovial haemangioma within the infrapatellar fat pad which showed both intra-articular and extra-articular extension. There was good correlation of the ultrasound findings with magnetic resonance imaging (MRI), highlighting the potential clinical utility of ultrasound as an alternative imaging modality in establishing the pre-operative diagnosis and extent of a synovial haemangioma about the knee joint.

  11. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    PubMed

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  12. Simple, almost anywhere, with almost anyone: remote low-cost telementored resuscitative lung ultrasound.

    PubMed

    McBeth, Paul B; Crawford, Innes; Blaivas, Michael; Hamilton, Trevor; Musselwhite, Kimberly; Panebianco, Nova; Melniker, Lawrence; Ball, Chad G; Gargani, Luna; Gherdovich, Carlotta; Kirkpatrick, Andrew W

    2011-12-01

    Apnea (APN) and pneumothorax (PTX) are common immediately life-threatening conditions. Ultrasound is a portable tool that captures anatomy and physiology as digital information allowing it to be readily transferred by electronic means. Both APN and PTX are simply ruled out by visualizing respiratory motion at the visceral-parietal pleural interface known as lung sliding (LS), corroborated by either the M-mode or color-power Doppler depiction of LS. We thus assessed how economically and practically this information could be obtained remotely over a cellular network. Ultrasound images were obtained on handheld ultrasound machines streamed to a standard free internet service (Skype) using an iPhone. Remote expert sonographers directed remote providers (with variable to no ultrasound experience) to obtain images by viewing the transmitted ultrasound signal and by viewing the remote examiner over a head-mounted webcam. Examinations were conducted between a series of remote sites and a base station. Remote sites included two remote on-mountain sites, a small airplane in flight, and a Calgary household, with base sites located in Pisa, Rome, Philadelphia, and Calgary. In all lung fields (20/20) on all occasions, LS could easily and quickly be seen. LS was easily corroborated and documented through capture of color-power Doppler and M-mode images. Other ultrasound applications such as the Focused Assessment with Sonography for Trauma examination, vascular anatomy, and a fetal wellness assessment were also demonstrated. The emergent exclusion of APN-PTX can be immediately accomplished by a remote expert economically linked to almost any responder over cellular networks. Further work should explore the range of other physiologic functions and anatomy that could be so remotely assessed.

  13. Non-Weight-Bearing and Weight-Bearing Ultrasonography of Select Foot Muscles in Young, Asymptomatic Participants: A Descriptive and Reliability Study.

    PubMed

    Battaglia, Patrick J; Mattox, Ross; Winchester, Brett; Kettner, Norman W

    The primary aim of this study was to determine the reliability of diagnostic ultrasound imaging for select intrinsic foot muscles using both non-weight-bearing and weight-bearing postures. Our secondary aim was to describe the change in muscle cross-sectional area (CSA) and dorsoplantar thickness when bearing weight. An ultrasound examination was performed with a linear ultrasound transducer operating between 9 and 12 MHz. Long-axis and short-axis ultrasound images of the abductor hallucis, flexor digitorum brevis, and quadratus plantae were obtained in both the non-weight-bearing and weight-bearing postures. Two examiners independently collected ultrasound images to allow for interexaminer and intraexaminer reliability calculation. The change in muscle CSA and dorsoplantar thickness when bearing weight was also studied. There were 26 participants (17 female) with a mean age of 25.5 ± 3.8 years and a mean body mass index of 28.0 ± 7.8 kg/m 2 . Inter-examiner reliability was excellent when measuring the muscles in short axis (intraclass correlation coefficient >0.75) and fair to good in long axis (intraclass correlation coefficient >0.4). Intraexaminer reliability was excellent for the abductor hallucis and flexor digitorum brevis and ranged from fair to good to excellent for the quadratus plantae. Bearing weight did not reduce interexaminer or intraexaminer reliability. All muscles exhibited a significant increase in CSA when bearing weight. This is the first report to describe weight-bearing diagnostic ultrasound of the intrinsic foot muscles. Ultrasound imaging is reliable when imaging these muscles bearing weight. Furthermore, muscle CSA increases in the weight-bearing posture. Copyright © 2016. Published by Elsevier Inc.

  14. [Ultrasound in the emergency department as an extension of the practitioner's clinical examination].

    PubMed

    Schmit, Aline; Pécoul, David; Lebret, Yannick; Dussoix, Philippe

    2018-01-31

    Ultrasound in the emergency department and general practice can be used as an extension of the physical examination, answering simple questions. It requires a short basic training that is easily accessible. This article illustrates with a few examples (kidney, lung and fractures) the interest of this formidable tool becoming unavoidable in the emergency department and general practice.

  15. Reliability Exercise for the Polymyalgia Rheumatica Classification Criteria Study: The Oranjewoud Ultrasound Substudy

    PubMed Central

    Scheel, Alexander K.; Matteson, Eric L.; Dasgupta, Bhaskar; Bruyn, George A. W.; Ohrndorf, Sarah; Werner, Carola; Schmidt, Wolfgang A.

    2009-01-01

    Objective. A study supported by the EULAR and the ACR being conducted to establish classification criteria for polymyalgia rheumatica (PMR) will include ultrasound examination of the shoulders and hips. Ultrasound (US) depicts glenohumeral joint effusion, biceps tenosynovitis, subdeltoid bursitis, hip joint synovitis, and trochanteric bursitis in PMR. These findings may aid in distinguishing PMR from other diseases. The purpose of this study was to assess standards and US interreader agreement of participants in the PMR classification criteria study. Methods. Sixteen physicians in four groups examined shoulders and hips of 4 patients and 4 healthy adults with ultrasound. Overall agreement and interobserver agreement were calculated. Results. The overall agreement (OA) between groups was 87%. The OA for healthy shoulders was 88.8%, for healthy hips 100%, for shoulders with pathology 85.2%, and 74.3% for hips with pathology, respectively. Conclusion. There was a high degree of agreement found for the examination of healthy shoulders and pathologic hips. Agreement was moderate for pathologic shoulders and perfect for healthy hips. US of shoulder and hips performed by different examiners is a reliable and feasible tool for assessment of PMR related disease pathology and can be incorporated into a classification criteria study. PMID:20130800

  16. Ultrasonographic examination of plantar fasciitis: a comparison of patient positions during examination.

    PubMed

    Ahn, Jae Hoon; Lee, Choong Woo; Park, ChanJoo; Kim, Yoon-Chung

    2016-01-01

    Musculoskeletal ultrasound is a non-invasive and low-cost modality for real-time visualisation of the plantar fascia. Ultrasound examination for plantar fasciitis is generally performed with the patient in a prone position, although the rational for using a prone position has not been validated. The aim of the study was to investigate if ultrasound examination in a supine position, which is more comfortable than the prone position, is valid. We conducted a prospective study of 30 participants with plantar fasciitis, 8 men (27 %) and 22 women (73 %), with a mean age of 53.9 ± 12.6 (range, 32 to 77) years, and an equal distribution of left and right feet. The plantar heel was divided into three portions for ultrasound examination: medial, central and lateral. Two measurements of plantar fascia thickness were obtained for each portion, with participants in 2 positions (supine and prone) and for 2 ankle postures (neutral and 15° of plantarflexion). Mean measurements of plantar fascia thickness were compared between the two positions (Wilcoxon signed rank tests for non-normally distributed data and paired t-tests for normally distributed data). Participants were asked to report their preferred position for examination, supine or prone. The measured thickness was comparable for both supine and prone positions, for both ankle postures, neutral and 15° of plantarflexion (p > 0.05). A specific self-reported preferred position was not identified. Ultrasound examination of plantar fasciitis can be performed in the supine position without any significant difference in measurement compared to examination in the conventional prone position. The Catholic Medical Center Office of Human Research Protection Program (CMC-OHRP)/Institutional Review Board approved the current study (Approval No. KC12DISI0338), and all participants provided their written informed consent for participation and publication.

  17. Measurement of fetal head descent using the 'angle of progression' on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise.

    PubMed

    Dückelmann, A M; Bamberg, C; Michaelis, S A M; Lange, J; Nonnenmacher, A; Dudenhausen, J W; Kalache, K D

    2010-02-01

    To assess whether ultrasound experience or fetal head station affects the reliability of measurement of fetal head descent using the angle of progression on intrapartum ultrasound images obtained by a single experienced operator, and to determine reliability of measurements when images were acquired by different operators with variable ultrasound experience. One experienced obstetrician performed 44 transperineal ultrasound examinations of women at term and in prolonged second stage of labor with the fetus in the occipitoanterior position. Three midwives without ultrasound experience, three obstetricians with < 5 years' experience and three obstetricians with > 10 years' experience measured fetal head descent based on the angle of progression in the images obtained. The angle of progression was measured by two obstetricians in independent ultrasound examinations of 24 laboring women at term with the fetus in the cephalic position to allow assessment of the reliability of image acquisition. Intraclass correlation coefficients (ICCs) with 95% confidence interval (CI) were used to evaluate interobserver reliability and Bland-Altman analysis was used to assess interobserver agreement. In total, 444 measurements were performed and compared. Interobserver reliability with respect to offline image analysis was substantial (overall ICC, 0.72; 95% CI, 0.63-0.81). ICCs were 0.82 (95% CI, 0.70-0.89), 0.81 (95% CI, 0.71-0.88) and 0.61 (95% CI, 0.43-074) for observers with > 10 years', < 5 years' and no ultrasound experience, respectively. There were no significant differences between ICCs among observer groups according to ultrasound experience. Fetal head station did not affect reliability. Bland-Altman analysis indicated reasonable agreement between measurements obtained by two different operators with > 10 years' and < 5 years' ultrasound experience (bias, -1.09 degrees ; 95% limits of agreement, -8.76 to 6.58). The reliability of measurement of the angle of progression following separate image acquisition by two experienced operators was similar to the reliability of offline image analysis (ICC, 0.86; 95% CI, 0.70-0.93). Measurement of the angle of progression on transperineal ultrasound imaging is reliable regardless of fetal head station or the clinician's level of ultrasound experience.

  18. Evaluation of left ventricular function by bedside ultrasound in acute toxic myocarditis.

    PubMed

    Brown, Cara; Budhram, Gavin

    2013-10-01

    Myocarditis can be difficult to diagnose in the Emergency Department (ED) due to the lack of classic symptoms and the wide variation in presentations. Poor cardiac contractility is a common finding in myocarditis and can be evaluated by bedside ultrasound. To demonstrate the utility of fractional shortening measurements as an estimation of left ventricular function during bedside cardiac ultrasound evaluation in the ED. A 54-year-old man presented to the ED complaining of 3 days of chest tightness, palpitations, and dyspnea, as well as persistent abdominal pain and vomiting. An electrocardiogram (ECG) showed sinus tachycardia with presumably new ST-segment elevation and signs of an incomplete right bundle branch block. A bedside echocardiogram was performed by the emergency physician that showed poor left ventricular function by endocardial fractional shortening measurements. On further questioning, the patient revealed that for the past 2 weeks he had been regularly huffing a commercially available compressed air duster. Based on these history and examination findings, the patient was given a presumptive diagnosis of toxic myocarditis. A follow-up echocardiogram approximately 7 weeks later demonstrated resolution of the left ventricular systolic dysfunction and his ECG findings normalized. Cardiac ultrasound findings of severely reduced global function measured by endocardial fractional shortening were seen in this patient and supported the diagnosis of myocarditis. Endocardial fractional shortening is a useful means of easily evaluating and documenting left ventricular function and can be performed at the bedside in the ED. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. [Is ultrasound equal to X-ray in pediatric fracture diagnosis?].

    PubMed

    Moritz, J D; Hoffmann, B; Meuser, S H; Sehr, D H; Caliebe, A; Heller, M

    2010-08-01

    Ultrasound is currently not established for the diagnosis of fractures. The aim of this study was to compare ultrasound and X-ray beyond their use solely for the identification of fractures, i. e., for the detection of fracture type and dislocation for pediatric fracture diagnosis. Limb bones of dead young pigs served as a model for pediatric bones. The fractured bones were examined with ultrasound, X-ray, and CT, which served as the gold standard. 162 of 248 bones were fractured. 130 fractures were identified using ultrasound, and 148 using X-ray. There were some advantages of X-ray over ultrasound in the detection of fracture type (80 correct results using X-ray, 66 correct results using ultrasound). Ultrasound, however, was superior to X-ray for dislocation identification (41 correct results using X-ray, 51 correct results using ultrasound). Both findings were not statistically significant after adjustment for multiple testing. Ultrasound not only has comparable sensitivity to that of X-ray for the identification of limb fractures but is also equally effective for the diagnosis of fracture type and dislocation. Thus, ultrasound can be used as an adequate alternative method to X-ray for pediatric fracture diagnosis. Georg Thieme Verlag KG Stuttgart, New York.

  20. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    PubMed

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  1. Imaging in gynecological disease (9): clinical and ultrasound characteristics of tubal cancer.

    PubMed

    Ludovisi, M; De Blasis, I; Virgilio, B; Fischerova, D; Franchi, D; Pascual, M A; Savelli, L; Epstein, E; Van Holsbeke, C; Guerriero, S; Czekierdowski, A; Zannoni, G; Scambia, G; Jurkovic, D; Rossi, A; Timmerman, D; Valentin, L; Testa, A C

    2014-03-01

    To describe clinical history and ultrasound findings in patients with tubal carcinoma. Patients with a histological diagnosis of tubal cancer who had undergone preoperative ultrasound examination were identified from the databases of 13 ultrasound centers. The tumors were described by the principal investigator at each contributing center on the basis of ultrasound images, ultrasound reports and research protocols (when applicable) using the terms and definitions of the International Ovarian Tumor Analysis (IOTA) group. In addition, three authors reviewed together all available digital ultrasound images and described them using subjective evaluation of gray-scale and color Doppler ultrasound findings. We identified 79 women with a histological diagnosis of primary tubal cancer, 70 of whom (89%) had serous carcinomas and 46 (58%) of whom presented at FIGO stage III. Forty-nine (62%) women were asymptomatic (incidental finding), whilst the remaining 30 complained of abdominal bloating or pain. Fifty-three (67%) tumors were described as solid at ultrasound examination, 14 (18%) as multilocular solid, 10 (13%) as unilocular solid and two (3%) as unilocular. No tumor was described as a multilocular mass. Most tumors (70/79, 89%) were moderately or very well vascularized on color or power Doppler ultrasound. Normal ovarian tissue was identified adjacent to the tumor in 51% (39/77) of cases. Three types of ultrasound appearance were identified as being typical of tubal carcinoma using pattern recognition: a sausage-shaped cystic structure with solid tissue protruding into it like a papillary projection (11/62, 18%); a sausage-shaped cystic structure with a large solid component filling part of the cyst cavity (13/62, 21%); an ovoid or oblong completely solid mass (36/62, 58%). A well vascularized ovoid or sausage-shaped structure, either completely solid or with large solid component(s) in the pelvis, should raise the suspicion of tubal cancer, especially if normal ovarian tissue is seen adjacent to it. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  2. Hepatic Sarcodosis presenting as portal hypertension in a young boy.

    PubMed

    Achakzai, Inamullah Khan; Majid, Zain; Khalid, Muhammad Ali; Khan, Shoaib Ahmed; Laeeq, Syed Mudassir; Luck, Nasir Hassan

    2018-01-01

    A 13-year-old boy, known case renal stone disease came with the complaints of abdominal pain along with low grade fever. On examination, hepatosplenomegaly was noted while his lab reports showed a low hemoglobulin with a raised ESR. His blood and urine cultures showed no growth. Viral markers, autoimmune profile, C and p ANCA were all negative apart from a raised serum IgG level. Ultrasound abdomen showed a hyperechoic liver with an enlarged spleen along with splenic varices and minimum ascites. Ultrasound hepatic doppler was normal. Serum AFP levels were normal while workup for Wilson's disease was negative. Fibroscan showed F4 fibosis. CT scan abdomen showed an enlarged left lobe of the liver along with an enlarged spleen. His EGD revealed varices. So liver biopsy was done that was suggestive of chronic granulomatous disease with ZN stain testing negative for TB.PPD, urine for AFB were both negative. Serum ACE levels were raised. He started ATT therapy but his condition did not improve. So, on the suspicion of hepatic sarcoidosis, he started on steroids and had a drastic improvement in his condition.

  3. Hepatic Sarcodosis presenting as portal hypertension in a young boy

    PubMed Central

    Achakzai, Inamullah Khan; Majid, Zain; Khalid, Muhammad Ali; Khan, Shoaib Ahmed; Laeeq, Syed Mudassir; Luck, Nasir Hassan

    2018-01-01

    A 13-year-old boy, known case renal stone disease came with the complaints of abdominal pain along with low grade fever. On examination, hepatosplenomegaly was noted while his lab reports showed a low hemoglobulin with a raised ESR. His blood and urine cultures showed no growth. Viral markers, autoimmune profile, C and p ANCA were all negative apart from a raised serum IgG level. Ultrasound abdomen showed a hyperechoic liver with an enlarged spleen along with splenic varices and minimum ascites. Ultrasound hepatic doppler was normal. Serum AFP levels were normal while workup for Wilson’s disease was negative. Fibroscan showed F4 fibosis. CT scan abdomen showed an enlarged left lobe of the liver along with an enlarged spleen. His EGD revealed varices. So liver biopsy was done that was suggestive of chronic granulomatous disease with ZN stain testing negative for TB.PPD, urine for AFB were both negative. Serum ACE levels were raised. He started ATT therapy but his condition did not improve. So, on the suspicion of hepatic sarcoidosis, he started on steroids and had a drastic improvement in his condition. PMID:29564070

  4. Acoustic pressure measurement of pulsed ultrasound using acousto-optic diffraction

    NASA Astrophysics Data System (ADS)

    Jia, Lecheng; Chen, Shili; Xue, Bin; Wu, Hanzhong; Zhang, Kai; Yang, Xiaoxia; Zeng, Zhoumo

    2018-01-01

    Compared with continuous ultrasound wave, pulsed ultrasound has been widely used in ultrasound imaging. The aim of this work is to show the applicability of acousto-optic diffraction on pulsed ultrasound transducer. In this paper, acoustic pressure of two ultrasound transducers is measured based on Raman-Nath diffraction. The frequencies of transducers are 5MHz and 10MHz. The pulse-echo method and simulation data are used to evaluate the results. The results show that the proposed method is capable to measure the absolute sound pressure. We get a sectional view of acoustic pressure using a displacement platform as an auxiliary. Compared with the traditional sound pressure measurement methods, the proposed method is non-invasive with high sensitivity and spatial resolution.

  5. Human Space Flight

    NASA Technical Reports Server (NTRS)

    Woolford, Barbara

    2006-01-01

    The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed just-in-time training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This just-in-time concept was used to support real-time remote expert guidance to complete medical examinations using the ISS Human Research Facility (HRF). An American md Russian ISS crewmember received 2-hours of hands on ultrasound training 8 months prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember six days prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. Results of the CD ROM based OPE session were used to modify the instructions during a complete 35 minute real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were excellent and adequate for clinical decision-making. Complex ultrasound experiments with expert guidance were performed with high accuracy following limited pre-flight training and CD-ROM-based in-flight review, despite a 2-second communication latency.

  6. Usefulness of emergency ultrasound in nontraumatic cardiac arrest.

    PubMed

    Volpicelli, Giovanni

    2011-02-01

    Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Coxsackie Virus A16 Infection of Placenta with Massive Perivillous Fibrin Deposition Leading to Intrauterine Fetal Demise at 36 Weeks Gestation.

    PubMed

    Yu, Weiming; Tellier, Raymond; Wright, James R

    2015-01-01

    Massive perivillous fibrin deposition (MPFD) is an uncommon placental disorder, associated with significant fetal morbidity, mortality, and recurrence; its etiology is unknown. We describe a 31-year-old mother, diagnosed with Coxsackievirus infection and hand-foot-and-mouth disease at 35 weeks gestation. Ultrasound at 35 weeks revealed a normal fetus and placenta. One week later, the mother experienced decreased fetal movement and ultrasound demonstrated intrauterine demise. The autopsy showed mild, acute pericarditis and hypoxic-ischemic encephalopathy. Placenta examination showed MPFD involving 80% of the parenchyma. Molecular viral analysis and serotyping showed Coxsackie A16 virus. The mother had an uneventful pregnancy 15 months later. Coxsackievirus infections in pregnant mothers are often asymptomatic. Transplacental Coxsackievirus infection is very rare but is associated with spontaneous abortion, intrauterine demise, or serious neonatal morbidity. Mild, nonspecific histologic changes have been reported in the placenta. To our knowledge, this is the first report of MPFD associated with Coxsackievirus infection.

  8. Ceramic membrane ultrafiltration of natural surface water with ultrasound enhanced backwashing.

    PubMed

    Boley, A; Narasimhan, K; Kieninger, M; Müller, W-R

    2010-01-01

    Ultrafiltration membrane cleaning with ultrasound enhanced backwashing was investigated with two ceramic membrane systems in parallel. One of them was subjected to ultrasound during backwashing, the other acted as a reference system. The feed water was directly taken from a creek with a sedimentation process as only pre-treatment. The cleaning performance was improved with ultrasound but after 3 weeks of operation damages occurred on the membranes. These effects were studied with online measurements of flux, trans-membrane-pressure and temperature, but also with integrity tests, turbidity measurements and visual examination.

  9. Prevalence of uterine myoma detected by ultrasound examination in the atomic bomb survivors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawamura, Sachiko; Kodama, Kazunori; Fujiwara, Saeko

    1997-06-01

    Benign tumors of several organs have been demonstrated to occur as late effects of atomic bomb exposure, and a recent addition to the list of affected organs in the uterus. The increased incidence of uterine myoma noted in Radiation Effects Research Foundation (REFR) Adult Health Study Report 7, however, was based on self-reported information, optional gynecological examination and patient-requested ultrasound examination. Thus the possibility of dose-related bias in case detection was a serious concern. Therefore, the relationship between the prevalence of uterine myoma and dose to the uterus was examined after excluding as much bias as possible by asking allmore » women who had undergone biennial examinations from December 1991 through December 1993 to undergo ultrasound examinations. Among 2506 female participants in Hiroshima, the uterus was visualized by ultrasound examination in 1190, and 238 were found to have uterine nodules. Multiple logistic analysis using Dosimetry System 1986 uterine doses revealed a significant dose response for the prevalence of uterine nodules. The odds ratio at 1 Gy was 1.61 (95% confidence interval: 1.12-2.31). It is unlikely that the observed relationship after adjusting for bladder filling, volume of the uterus, age and menopause status was the result of dose-related bias. These results support previous findings at RERF and provide further evidence that radiation exposure is one of the factors associated with uterine myoma. 28 refs., 3 figs., 4 tabs.« less

  10. Simplified medical abortion screening: a demonstration project.

    PubMed

    Raymond, Elizabeth G; Tan, Yi-Ling; Comendant, Rodica; Sagaidac, Irina; Hodorogea, Stelian; Grant, Melissa; Sanhueza, Patricio; Van Pratt, Emigdio; Gillespie, Ginger; Boraas, Christy; Weaver, Mark A; Platais, Ingrida; Bousieguez, Manuel; Winikoff, Beverly

    2018-04-01

    The objectives were to evaluate the safety and acceptability of outpatient medical abortion in selected women without a pretreatment ultrasound or pelvic examination. We conducted a prospective case-series study to estimate the incidence of serious adverse events (death, life-threatening event, hospitalization, transfusion or any other medical problem that we judged to be significant), surgical completion of the abortion and satisfaction in women provided with medical abortion without a pretreatment ultrasound or pelvic examination. We enrolled 406 women requesting medical abortion in Moldova, Mexico and the United States. To be eligible, a woman must have been certain that her last menstrual period started within the prior 56days, have had regular menses before the pregnancy, not have used hormonal contraceptives in the prior 2months (in the United States and Mexico) or 3months (in Moldova), have no risk factors for or symptoms of ectopic pregnancy, and not have had an ultrasound or pelvic exam in this pregnancy. One site also excluded women with uterine enlargement on abdominal palpation. Each participant received mifepristone (200mg orally) and misoprostol (400 mcg sublingually in Moldova; 800 mcg buccally at all other sites) and was followed until complete abortion, defined as requiring no further treatment. Of the 365 (90%) participants who provided sufficient follow-up information for analysis, 347 (95%) had complete abortion without additional treatment, 5 (1%) had surgical aspiration, and 10 (3%) had extra misoprostol. Three participants (1%) had serious adverse events; these included two hospital admissions for heavy bleeding managed with aspiration and one diagnosis of persistent gestational sac 19days after enrollment. Most (317, 90%) participants were pleased with omitting the pretreatment ultrasound and pelvic exam. In this study, medical abortion without screening ultrasound or pelvic exam resulted in no serious adverse events that were likely to have been prevented by those tests and was highly acceptable. Screening for medical abortion without exam or ultrasound shows promise as a means for increasing access to this service. More research is needed to develop screening criteria that are more inclusive and simpler for clinical use. Copyright © 2017. Published by Elsevier Inc.

  11. Towards enabling ultrasound guidance in cervical cancer high-dose-rate brachytherapy

    NASA Astrophysics Data System (ADS)

    Wong, Adrian; Sojoudia, Samira; Gaudet, Marc; Yap, Wan Wan; Chang, Silvia D.; Abolmaesumi, Purang; Aquino-Parsons, Christina; Moradi, Mehdi

    2014-03-01

    MRI and Computed Tomography (CT) are used in image-based solutions for guiding High Dose Rate (HDR) brachytherapy treatment of cervical cancer. MRI is costly and CT exposes the patients to ionizing radiation. Ultrasound, on the other hand, is affordable and safe. The long-term goal of our work is to enable the use of multiparametric ultrasound imaging in image-guided HDR for cervical cancer. In this paper, we report the development of enabling technology for ultrasound guidance and tissue typing. We report a system to obtain the 3D freehand transabdominal ultrasound RF signals and B-mode images of the uterus, and a method for registration of ultrasound to MRI. MRI and 3D ultrasound images of the female pelvis were registered by contouring the uterus in the two modalities, creating a surface model, followed by rigid and B-spline deformable registration. The resulting transformation was used to map the location of the tumor from the T2-weighted MRI to ultrasound images and to determine cancerous and normal areas in ultrasound. B-mode images show a contrast for cancer vs. normal tissue. Our study shows the potential and the challenges of ultrasound imaging in guiding cervical cancer treatments.

  12. Biological Effects of Acoustic Cavitation

    DTIC Science & Technology

    1985-06-15

    call attention to four important ones: Ter Haar et.al. (25-26] have irradiated live guinea pig legs with therapeutic ultrasound while examining the...eggs and larvae * at various stages in their development with pulsed ultrasound . They have determined that when gas-containing trachea developed in...the organisms, they were extremely suceptable to the ultrasound and large fractions could - be killedý Hemmingsen et.al. [30-311 have observed bubble

  13. Prenatal diagnosis of parapagus diprosopus dibrachius dipus twins with spina bifida in the first trimester using two- and three-dimensional ultrasound.

    PubMed

    Yang, Pei-Yin; Wu, Ching-Hua; Yeh, Guang-Perng; Hsieh, Charles Tsung-Che

    2015-12-01

    Here, we report a case of parapagus diprosopus twins with spina bifida diagnosed in the first trimester of pregnancy using two-dimensional (2D) and three-dimensional (3D) ultrasound. A 28-year-old Taiwanese woman, gravid 1, para 0, visited our hospital due to an abnormal fetal head shape discovered by 2D ultrasound at 11-weeks gestation. Parapagus diprosopus twins with spina bifida were diagnosed after ultrasound examination. The characteristics of parapagus diprosopus twins are more illustrative in 3D ultrasound than in 2D ultrasound. After counseling, termination of pregnancy was chosen by the couple. Although necropsy was declined, the gross appearance and radiograph of the abortus confirmed our diagnosis. With the help of 3D ultrasound, we made an early and definitive diagnosis of conjoined twins. Copyright © 2015. Published by Elsevier B.V.

  14. The potential of ultrasound in cardiac pacing and rhythm modulation.

    PubMed

    Kohut, Andrew R; Vecchio, Christopher; Adam, Dan; Lewin, Peter A

    2016-09-01

    This review examines the potential for ultrasound to induce or otherwise influence cardiac pacing and rhythm modulation. Of particular interest is the possibility of developing new, truly non-invasive, nonpharmacological, acute and chronic, ultrasound-based arrhythmia treatments. Such approaches would not depend upon implanted or indwelling devices of any kind and would use ultrasound at diagnostic exposure levels (so as not to harm the heart or surrounding tissues). It is known that ultrasound can cause cardiomyocyte depolarization and a variety of underlying mechanisms have been proposed. Expert commentary: Questions still remain regarding the effect of exposure parameters and work will also be necessary to identify the optimal target regions within the heart if ultrasound energy is to be used to induce safe and reliable pacing in a clinical setting.

  15. The utility of ultrasound in patients with melanoma.

    PubMed

    Uren, Roger F; Sanki, Amira; Thompson, John F

    2007-11-01

    The highest quality gray-scale ultrasound images are obtained with high-frequency transducers; however, such high frequencies do not penetrate more than a few centimeters into body tissue. Fortunately, in patients with melanoma, the structures of interest are close to the skin surface, making them ideal targets for examination with high-resolution ultrasound. These include primary cutaneous melanomas, uveal melanomas and the regional lymph nodes draining the skin that lie in the axilla, groin, neck and other locations. Although ultrasound study of primary melanomas arising in the skin and eye has provided some insights, a major role for ultrasound has evolved recently, to provide early detection of metastatic melanoma in regional lymph nodes. Ultrasound is clearly superior to clinical palpation of the nodes during follow-up and, when combined with guided fine-needle biopsy, allows the earliest possible surgical intervention for regional nodal metastases. In the future the use of ultrasound contrast agents may improve the sensitivity of ultrasound in the detection of very small metastatic deposits.

  16. VEGFR2-Targeted Ultrasound Imaging Agent Enhances the Detection of Ovarian Tumors at Early Stage in Laying Hens, a Preclinical Model of Spontaneous Ovarian Cancer.

    PubMed

    Barua, Animesh; Yellapa, Aparna; Bahr, Janice M; Machado, Sergio A; Bitterman, Pincas; Basu, Sanjib; Sharma, Sameer; Abramowicz, Jacques S

    2015-07-01

    Tumor-associated neoangiogenesis (TAN) is an early event in ovarian cancer (OVCA) development. Increased expression of vascular endothelial growth factor receptor 2 (VEGFR2) by TAN vessels presents a potential target for early detection by ultrasound imaging. The goal of this study was to examine the suitability of VEGFR2-targeted ultrasound contrast agents in detecting spontaneous OVCA in laying hens. Effects of VEGFR2-targeted contrast agents in enhancing the intensity of ultrasound imaging from spontaneous ovarian tumors in hens were examined in a cross-sectional study. Enhancement in the intensity of ultrasound imaging was determined before and after injection of VEGFR2-targeted contrast agents. All ultrasound images were digitally stored and analyzed off-line. Following scanning, ovarian tissues were collected and processed for histology and detection of VEGFR2-expressing microvessels. Enhancement in visualization of ovarian morphology was detected by gray-scale imaging following injection of VEGFR2-targeted contrast agents. Compared with pre-contrast, contrast imaging enhanced the intensities of ultrasound imaging significantly (p < 0.0001) irrespective of the pathological status of ovaries. In contrast to normal hens, the intensity of ultrasound imaging was significantly (p < 0.0001) higher in hens with early stage OVCA and increased further in hens with late stage OVCA. Higher intensities of ultrasound imaging in hens with OVCA were positively correlated with increased (p < 0.0001) frequencies of VEGFR2-expressing microvessels. The results of this study suggest that VEGFR2-targeted contrast agents enhance the visualization of spontaneous ovarian tumors in hens at early and late stages of OVCA. The laying hen may be a suitable model to test new imaging agents and develop targeted therapeutics. © The Author(s) 2014.

  17. Validation of Ultrasound Imaging to Rule-out Thoracic Trauma on the International Space Station

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Melton, Shannon; Martin, David; Dulchavsky, Scott A.

    2006-01-01

    Introduction: Aboard the International Space Station (ISS) an intra-thoracic injury may be disastrous to the crew member if the diagnosis is missed or even delayed. Pneumothorax and hemothorax commonly seen in trauma patients; the diagnosis is usually confirmed by chest X-ray or computed tomography. In this study, the ability of ultrasound to rule out pneumothorax by the presence "lung sliding" and hemothorax by the absence of pleural fluid was validated. Methods: The research activities were approved by the NASA Johnson Space Center Committee for the Protection of Human Subjects, and the participating crewmembers signed informed consent prior to the activity. ISS crewmembers received 2-hours of "hands on" ultrasound training 8 months prior to the on-orbit ultrasound exam. Baseline ultrasound images of the thorax were acquired on the crewmebers of Increment 8 and 9 prior to launch from Bakonur, Russia. Ultrasound examination of the thorax were performed on crewmembers at 30 day intervals (n=??) throughout their flight. Post flight images were acquired on or about landing day 10. Ultrasound images were acquired using the ISS Health Research Facility ultrasound system and examined by experts on the ground to rule out the presence of pneumothorax and hemothorax. Results: The presence of "lung sliding" which excludes pneumothorax, was seen in all subjects. The absence of pleural fluid, which excludes hemothorax was seen in all subjects. The optimal position between sonographer and patient under microgravity conditions and the amount and type of training for a non-physician crew medical officer for these procedures was also established for this procedure. Conclusion: Ultrasound can be performed on orbit under microgravity condition to rule thoracic trauma, such as pneumothorax and hemothorax.

  18. Usefulness of the twinkling artifact on Doppler ultrasound for the detection of breast microcalcifications.

    PubMed

    Relea, A; Alonso, J A; González, M; Zornoza, C; Bahamonde, S; Viñuela, B E; Encinas, M B

    2018-06-12

    To determine whether the twinkling artifact on Doppler ultrasound imaging corresponds to microcalcifications previously seen on mammograms and to evaluate the usefulness of this finding in the ultrasound management of suspicious microcalcifications. We used ultrasonography to prospectively examine 46 consecutive patients with groups of microcalcifications suspicious for malignancy identified at mammography, searching for the presence of the twinkling artifact to identify the microcalcifications. Once we identified the microcalcifications, we obtained core-needle biopsy specimens with 11G needles and then used X-rays to check the specimens for the presence of microcalcifications. We analyzed the percentage of detection and obtainment of microcalcifications by core-needle biopsy with this technique and the radiopathologic correlation. Microcalcifications that were not detected by ultrasound or discordant lesions were biopsied by stereotaxy at another center. We also used ultrasound guidance for preoperative marking with clips, usually orienting them radially. We identified and biopsied 41 of the 46 lesions under ultrasound guidance, including 24 of 25 carcinomas (17 in situ). B-mode ultrasound was sufficient for biopsying the microcalcifications in 14 patients, although the presence of the twinkling artifact increased the number of microcalcifications detected and thus enabled more accurate preoperative marking. Thanks to the twinkling sign, we were able to identify 27 additional groups of microcalcifications (89% vs. 30%; p < 0.05). All the surgical specimens had margins free of disease. The twinkling artifact is useful for microcalcifications in ultrasound examinations, enabling a significant increase in the yield of ultrasound-guided biopsies and better preoperative marking of groups of microcalcifications. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Bilateral megalocystic ovaries following in vitro fertilization detected during cesarean section: a case presentation.

    PubMed

    Alptekin, Hüsnü; Gezginç, Kazım; Yılmaz, Fatma Yazıcı

    2012-01-01

    We present a patient with persistent bilateral megalocystic ovaries following in vitro fertilization which was detected during cesarean section. A 24 year-old primigravida presented to our clinic at the 36(th) week of a twin pregnancy with labour pain and cervical dilatation. On ultrasound examination, 2 masses of 90×60 and 60×70 mm were seen in the right and left adnexal regions respectively. Her history showed that she had unexplained infertility for 4 years and had undergone IVF with gonadotropin releasing hormone (GnRH)-agonist stimulation. Two embryos were transferred. Twin pregnancy was detected on ultrasound examination. The patient was delivered by emergency caesarean section due to transverse presentations at 36(th) weeks of gestation. During the operation, both adnexae were markedly enlarged, the right ovary measuring about 15×18 cm and the left about 16×18 cm. There was minimal ascites in the abdominal cavity. Ovarian biopsy was performed and the final pathology report showed bilateral follicle cysts. The patient was discharged on the postoperative 4(th) day. The patient was seen 4 weeks later. She had no complaints and ultrasound follow-up revealed a normal size uterus and ovaries. We should keep in mind that hyperstimulated, enlarged ovaries and its complication may be seen in the late weeks of pregnancy, even at term, in cases of in vitro fertilization cases. Therefore, close follow-up of pregnant IVF patints is recommended whether they had OHSS or not, because ovarian torsion caused by hyperstimulated ovaries may be difficult to diagnose during pregnancy.

  20. Studies on the foundation and development of diagnostic ultrasound

    PubMed Central

    Wagai, Toshio

    2007-01-01

    In recent years, various types of diagnostic imaging methods, such as CT, MRI, PET and Ultrasound, have been developed rapidly and become indispensable as clinical diagnostic tools. Among these imaging modalities, CT, MRI and PET all apply electromagnetic waves like radiation rays. In contrast, an ultrasound imaging method uses a completely different mechanical pressure wave: “sound”. Ultrasound has various features, including inaudible sound at very high frequencies, which allows its use in medical diagnoses. That is, ultrasound techniques can be applied in transmission, reflection and Doppler methods. Moreover, the sharp directivity of an ultrasound beam can also improve image resolution. Another big advantage of diagnostic ultrasound is that it does not harm the human body or cause any pain to patients. Given these various advantages, diagnostic ultrasound has recently been widely used in diagnosing cancer and cardiovascular disease and scanning fetuses (Fig. 1) as well as routine clinical examinations in hospitals. In this paper, I outline my almost 50-year history of diagnostic ultrasound research, particularly that performed at the early stage from 1950–56. PMID:24367150

  1. Spinal curvature measurement by tracked ultrasound snapshots.

    PubMed

    Ungi, Tamas; King, Franklin; Kempston, Michael; Keri, Zsuzsanna; Lasso, Andras; Mousavi, Parvin; Rudan, John; Borschneck, Daniel P; Fichtinger, Gabor

    2014-02-01

    Monitoring spinal curvature in adolescent kyphoscoliosis requires regular radiographic examinations; however, the applied ionizing radiation increases the risk of cancer. Ultrasound imaging is favored over radiography because it does not emit ionizing radiation. Therefore, we tested an ultrasound system for spinal curvature measurement, with the help of spatial tracking of the ultrasound transducer. Tracked ultrasound was used to localize vertebral transverse processes as landmarks along the spine to measure curvature angles. The method was tested in two scoliotic spine models by localizing the same landmarks using both ultrasound and radiographic imaging and comparing the angles obtained. A close correlation was found between tracked ultrasound and radiographic curvature measurements. Differences between results of the two methods were 1.27 ± 0.84° (average ± SD) in an adult model and 0.96 ± 0.87° in a pediatric model. Our results suggest that tracked ultrasound may become a more tolerable and more accessible alternative to radiographic spine monitoring in adolescent kyphoscoliosis. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. OVERALL PROCEDURES PROTOCOL AND PATIENT ENROLLMENT PROTOCOL: TESTING FEASIBILITY OF 3D ULTRASOUND DATA ACQUISITION AND RELIABILITY OF DATA RETRIEVAL FROM STORED 3D IMAGES

    EPA Science Inventory

    The purpose of this study is to examine the feasibility of collecting, transmitting,

    and analyzing 3-D ultrasound data in the context of a multi-center study of pregnant

    women. The study will also examine the reliability of measurements obtained from 3-D

    imag...

  3. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    PubMed

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  4. A liver cirrhosis classification on B-mode ultrasound images by the use of higher order local autocorrelation features

    NASA Astrophysics Data System (ADS)

    Sasaki, Kenya; Mitani, Yoshihiro; Fujita, Yusuke; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-02-01

    In this paper, in order to classify liver cirrhosis on regions of interest (ROIs) images from B-mode ultrasound images, we have proposed to use the higher order local autocorrelation (HLAC) features. In a previous study, we tried to classify liver cirrhosis by using a Gabor filter based approach. However, the classification performance of the Gabor feature was poor from our preliminary experimental results. In order accurately to classify liver cirrhosis, we examined to use the HLAC features for liver cirrhosis classification. The experimental results show the effectiveness of HLAC features compared with the Gabor feature. Furthermore, by using a binary image made by an adaptive thresholding method, the classification performance of HLAC features has improved.

  5. Right Upper Quadrant Pain: Ultrasound First!

    PubMed

    Revzin, Margarita V; Scoutt, Leslie M; Garner, Joseph G; Moore, Christopher L

    2017-10-01

    Acute right upper quadrant (RUQ) pain is a common presenting symptom in emergency departments and outpatient medical practices, and is most commonly attributable to biliary and hepatic pathology. Ultrasound should be used as a first-line imaging modality for the diagnosis of gallstones and cholecystitis, as it allows the differentiation of medical and surgical causes of upper abdominal pathology, and in many circumstances is sufficient to guide patient management. Knowledge of strengths and limitations of ultrasound in the evaluation of RUQ is paramount in correct diagnosis. A spectrum of RUQ pathology for which a RUQ ultrasound examination should reasonably be considered as the initial imaging modality of choice will be reviewed. © 2017 by the American Institute of Ultrasound in Medicine.

  6. Two-Dimensional and Three-Dimensional Ultrasound of Artificial Skin.

    PubMed

    Wortsman, Ximena; Navarrete, Nelson

    2017-01-01

    Wound healing may be a difficult problem, and variable types of artificial skin prototypes have been developed for supporting this process. Using ultrasound, we studied 4 cellulose-derived artificial skin prototypes and assessed their two-dimensional and three-dimensional morphology. These prototypes were identified on ultrasound both on in vitro and in vivo studies. They allowed the sonographic observation of deeper layers on different types of surfaces of the body with good definition on the in vivo examinations performed on healthy skin and cutaneous ulcers. The ultrasound detection of these artificial biomaterials may potentially support the noninvasive monitoring of wound healing. © 2016 by the American Institute of Ultrasound in Medicine.

  7. Ultrasound-guided percutaneous lavage of calcific bursitis of the medial collateral ligament of the knee: a case report and review of the literature.

    PubMed

    Del Castillo-González, Federico; Ramos-Álvarez, Juan José; González-Pérez, José; Jiménez-Herranz, Elena; Rodríguez-Fabián, Guillermo

    2016-10-01

    Calcification of the medial collateral ligament (MCL) of the knee is rare. The literature reports no positive outcomes when conservative treatment has been followed. This paper reports a case of such calcification and its treatment using ultrasound-guided percutaneous lavage (UGPL). A 66-year-old patient presented with medial knee pain. X-ray, ultrasound, and magnetic resonance (MR) examinations revealed calcific bursitis of the MCL, which was treated by UGPL. One month after treatment the patient was asymptomatic. X-ray, ultrasound, and MR examinations confirmed the almost complete disappearance of the calcification; only very tiny fragments remained. Calcific bursitis of the MCL of the knee is very uncommon, but should be taken into account in differential diagnoses for medial knee pain. UGPL is proposed as a treatment for this condition.

  8. Evaluation of ultrasound techniques for brain injury detection

    NASA Astrophysics Data System (ADS)

    Mobley, Joel; Kasili, Paul M.; Norton, Stephen J.; Vo-Dinh, Tuan

    1998-05-01

    In this work, we examine the physics underlying wave propagation in the head to evaluate various ultrasonic transducers for use in a brian injury detection device. The results of measurements of the attenuation coefficient and phase velocity for ultrasonic propagation in samples of brain tissue and skull bone from sheep are presented. The material properties are then used to investigate the propagation of ultrasonic pressure fields in the head. The ultrasound fields for three different transducers are calculated for propagation in a simulated brain/skull model. The model is constructed using speed-of-sound and mass density values of the two tissue types. The impact of the attenuation on the ultrasound fields is then examined. Finally, the relevant points drawn from these discussions are summarized. We hope to minimize the confounding effects of the skull by using sub-MHz ultrasound while maintaining the necessary temporal and spatial resolution to successfully detect injury in the brain.

  9. Effect of mild pressure applied by the ultrasound transducer on fetal cephalic measurements at 20-24 weeks' gestation.

    PubMed

    Kliper, Yael; Ben-Ami, Moshe; Perlitz, Yuri

    2014-01-01

    The aim of this study was to assess the effect of mild pressure applied on the abdominal wall by the ultrasound transducer on fetal cephalic indices. We examined by ultrasound 60 fetuses of healthy women, at 20-24 weeks of pregnancy, during routine prenatal evaluation. For every fetus biparietal diameter and head circumference were measured, with and without applying mild pressure by the ultrasound transducer. The weight and gestational age (GA) were calculated. The pressure applied by the transducer had a significant effect on the cephalic indices and on the weight and GA evaluations (p < 0.001). Fetal positioning significantly affected the impact that applied pressure had on head circumference and on the weight evaluation derived from it (p < 0.05). Applied pressure by an abdominal ultrasound probe affects cephalic indices and the derived weight and GA estimations. This may lead to incorrect diagnoses or hide pathological findings. The effect of applied pressure depends on fetal positioning. The examiner must be aware of this effect when evaluating the results of the measurements.

  10. Gestational age assessment in malaria pregnancy cohorts: a prospective ultrasound demonstration project in Malawi.

    PubMed

    Wylie, Blair J; Kalilani-Phiri, Linda; Madanitsa, Mwayi; Membe, Gladys; Nyirenda, Osward; Mawindo, Patricia; Kuyenda, Redson; Malenga, Albert; Masonbrink, Abbey; Makanani, Bonus; Thesing, Phillip; Laufer, Miriam K

    2013-06-04

    Malaria during pregnancy is associated with an increased risk for low birth weight (<2500 grams). Distinguishing infants that are born premature (< 37 weeks) from those that are growth-restricted (less than the 10th percentile at birth) requires accurate assessment of gestational age. Where ultrasound is accessible, sonographic confirmation of gestational age is more accurate than menstrual dating. The goal was to pilot the feasibility and utility of adding ultrasound to an observational pregnancy malaria cohort. In July 2009, research staff (three mid-level clinical providers, one nurse) from The Blantyre Malaria Project underwent an intensive one-week ultrasound training to perform foetal biometry. Following an additional four months of practice and remote image review, subjects from an ongoing cohort were recruited for ultrasound to determine gestational age. Gestational age at delivery established by ultrasound was compared with postnatal gestational age assessment (Ballard examination). One hundred and seventy-eight women were enrolled. The majority of images were of good quality (94.3%, 509/540) although a learning curve was apparent with 17.5% (24/135) images of unacceptable quality in the first 25% of scans. Ultrasound was used to date 13% of the pregnancies when menstrual dates were unknown and changed the estimated gestational age for an additional 25%. There was poor agreement between the gestational age at delivery as established by the ultrasound protocol compared to that determined by the Ballard examination (bias 0.8 weeks, limits of agreement -3.5 weeks to 5.1 weeks). The distribution of gestational ages by Ballard suggested a clustering of gestational age around the mean with 87% of the values falling between 39 and 41 weeks. The distribution of gestational age by ultrasound confirmed menstrual dates was more typical. Using ultrasound confirmed dates as the gold standard, 78.5% of preterm infants were misclassified as term and 26.8% of small-for gestational age infants misclassified as appropriately grown by Ballard. Ultrasound should be strongly considered in prospective malaria studies with obstetric endpoints to confirm gestational age and avoid misclassification of infants as premature or growth-restricted. The use of ultrasound does require a significant investment of time to maintain quality image acquisition.

  11. ‘Women think pregnancy management means obstetric ultrasound’: Vietnamese obstetricians’ views on the use of ultrasound during pregnancy

    PubMed Central

    Edvardsson, Kristina; Graner, Sophie; Thi, Lan Pham; Åhman, Annika; Small, Rhonda; Lalos, Ann; Mogren, Ingrid

    2015-01-01

    Objective To explore Vietnamese obstetricians’ experiences and views on the role of obstetric ultrasound in clinical management of complicated pregnancy and in situations where maternal and fetal health interests conflict. Design Seventeen obstetricians in northern Vietnam were interviewed as part of the CROss-Country Ultrasound Study (CROCUS) project in 2013. Data were analysed using qualitative content analysis. Results The participants described ultrasound as a central tool in prenatal care, although they called for increased training and resources to prevent inappropriate management. A prevailing overuse driven by women's request and increased commercialisation was described. Other clinical examinations were seen as being disregarded by women in favour of ultrasound, resulting in missed opportunities for identifying potential pregnancy complications. The use of ultrasound for sex selection purposes raised concern among participants. Visualisation of human features or heartbeat during ultrasound was commonly described as the point where the fetus became regarded as a ‘person’. Women were said to prioritise fetal health interests over their own health, particularly if a woman had difficulties becoming pregnant or had undergone assisted fertilisation. The woman's husband and his family were described as having an important role in decision-making in situations of maternal and fetal health conflicts. Conclusions This study provides insight into issues surrounding ultrasound use in contemporary Vietnam, some of which may be specific to this low-income context. It is clear that ultrasound has become a central tool in prenatal care in Vietnam and that it has also been embraced by women. However, there seems to be a need to balance women's demands for obstetric ultrasound with better recognition of the valuable contribution to be made by the full range of clinical examinations in pregnancy, along with a more strategic allocation of resources, that is, use of obstetric ultrasound based on clinical indications. Better regulation of private obstetric practice also appears to be needed. While the root causes of sex selection need to be addressed at societal level, efforts are also required more immediately to find ways to combat the inappropriate use of ultrasound for the purpose of sex selection. PMID:26519131

  12. Studies on the use of power ultrasound in leather dyeing.

    PubMed

    Sivakumar, Venkatasubramanian; Rao, Paruchuri Gangadhar

    2003-03-01

    Uses of power ultrasound for acceleration/performing the chemical as well as physical processes are gaining importance. In conventional leather processing, the diffusion of chemicals through the pores of the skin/hide is achieved by the mechanical agitation caused by the paddle or drumming action. In this work, the use of power ultrasound in the dyeing of leather has been studied with the aim to improve the exhaustion of dye for a given processing time, to reduce the dyeing time and to improve the quality of dyed leather. The effect of power ultrasound in the dyeing of full chrome cow crust leather in a stationary condition is compared with dyeing in the absence of ultrasound as a control experiment both in a stationary as well as conventional drumming condition. An ultrasonic cleaner (150 W and 33 kHz) was used for the experiments. Actual power dissipated into the system was calculated from the calorimetric measurement. Experiments were carried out with variation in type of dye, amount of dye offer, temperature and time. The results show that there is a significant improvement in the percentage exhaustion of dye due to the presence of ultrasound, when compared to dyeing in absence of ultrasound. Experiments on equilibrium dye uptake carried out with or without ultrasound suggest that ultrasound help to improve the kinetics of leather dyeing. The results indicate that leathers dyed in presence of ultrasound have higher colour values, better dye penetration and fastness properties compared to control leathers. The physical testing results show that strength properties of the dyed leathers are not affected due to the application of ultrasound under the given process conditions. Apparent diffusion coefficient during the initial stage of dyeing process, both in presence and in absence of ultrasound was calculated. The values show that ultrasound helps in improving the apparent diffusion coefficient more for the difficult dyeing conditions such as in the case of metal-complex dyes having bigger aggregate size compared to less difficult dyeing conditions.

  13. Ultrasound in the evaluation of enthesitis: status and perspectives.

    PubMed

    Gandjbakhch, Frédérique; Terslev, Lene; Joshua, Fredrick; Wakefield, Richard J; Naredo, Esperanza; D'Agostino, Maria Antonietta

    2011-01-01

    An increasing number of studies have applied ultrasound to the evaluation of entheses in spondyloarthritis patients. However, no clear agreement exists on the definition of enthesitis, on the number and choice of entheses to examine and on ultrasound technique, which may all affect the results of the examination. The objectives of this study were to first determine the level of homogeneity in the ultrasound definitions for the principal lesions of enthesitis in the published literature and second, to evaluate the metric properties of ultrasound for detecting enthesitis according to the OMERACT filter. Search was performed in PUBMED and EMBASE. Both grey-scale and Doppler definitions of enthesitis, including describing features of enthesitis, were collected and metrological qualities of studies were assessed. After selection, 48 articles were analyzed. The definition of ultrasound enthesitis and elementary features varied among authors. Grey-scale enthesitis was characterized by increasing thickness (94% of studies), hypoechogenicity (83%), enthesophytes (69%), erosions (67%), calcifications (52%), associated bursitis (46%) and cortical irregularities (29%). Only 46% of studies reported the use of Doppler. High discrepancies were observed on frequency, type of probe and Doppler mode used. Face and content validity were the most frequently evaluated criteria (43%) followed by reliability (29%) and responsiveness (19%). Ultrasound has evidence to support face, content validity and reliability for the evaluation of enthesitis, though there is a lack of well-reported methodology in most of the studies. Consensus on elementary lesions and standardization of exam is needed to determine the ultrasound definition of enthesitis in grey-scale and in Doppler for future applications.

  14. ASSOCIATIONS BETWEEN ULTRASOUND AND CLINICAL FINDINGS IN 87 CATS WITH URETHRAL OBSTRUCTION.

    PubMed

    Nevins, Jonathan R; Mai, Wilfried; Thomas, Emily

    2015-01-01

    Urethral obstruction is a life-threatening form of feline lower urinary tract disease. Ultrasonographic risk factors for reobstruction have not been previously reported. Purposes of this retrospective cross-sectional study were to describe urinary tract ultrasound findings in cats following acute urethral obstruction and determine whether ultrasound findings were associated with reobstruction. Inclusion criteria were a physical examination and history consistent with urethral obstruction, an abdominal ultrasound including a full evaluation of the urinary system within 24 h of hospitalization, and no cystocentesis prior to ultrasound examination. Medical records for included cats were reviewed and presence of azotemia, hyperkalemia, positive urine culture, and duration of hospitalization were recorded. For medically treated cats with available outcome data, presence of reobstruction was also recorded. Ultrasound images were reviewed and urinary tract characteristics were recorded. A total of 87 cats met inclusion criteria. Common ultrasound findings for the bladder included echogenic urine sediment, bladder wall thickening, pericystic effusion, hyperechoic pericystic fat, and increased urinary echoes; and for the kidneys/ureters included pyelectasia, renomegaly, perirenal effusion, hyperechoic perirenal fat, and ureteral dilation. Six-month postdischarge outcomes were available for 61 medically treated cats and 21 of these cats had reobstruction. No findings were associated with an increased risk of reobstruction. Ultrasonographic perirenal effusion was associated with severe hyperkalemia (P = 0.009, relative risk 5.75, 95% confidence interval [1.54-21.51]). Findings supported the use of ultrasound as an adjunct for treatment planning in cats presented with urethral obstruction but not as a method for predicting risk of reobstruction. © 2015 American College of Veterinary Radiology.

  15. Randomized, controlled trial of biofeedback with anal manometry, transanal ultrasound, or pelvic floor retraining with digital guidance alone in the treatment of mild to moderate fecal incontinence.

    PubMed

    Solomon, Michael J; Pager, Chet K; Rex, Jenny; Roberts, Rachael; Manning, Jane

    2003-06-01

    A prospective, three-armed, randomized, controlled trial was performed to assess whether pelvic floor exercises with biofeedback using anal manometry or transanal ultrasound are superior to pelvic floor exercises with feedback from digital examination alone in terms of continence, quality of life, physiologic sphincter strength, and compliance. Its secondary objectives were to assess whether there are any differences in these outcomes between biofeedback with transanal ultrasound vs. anal manometry and to correlate the physiologic measures with clinical outcome. One hundred twenty patients with mild to moderate fecal incontinence were randomized into one of three treatment groups: biofeedback with anal manometry, biofeedback with transanal ultrasound, or pelvic floor exercises with feedback from digital examination alone. Commencing one week after an initial 45-minute assessment session, patients attended monthly treatments for a total of five sessions. Each session lasted 30 minutes and involved sphincter exercises with biofeedback that involved instrumentation or digital examination alone, and patients were encouraged to perform identical exercises twice per day between outpatient visits. One hundred two patients (85 percent) completed the four-month treatment program. Across all treatment allocations, patients experienced modest but highly significant improvements in all nine outcome measures during treatment, with 70 percent of all patients perceiving improvement in symptom severity and 69 percent of patients reporting improved quality of life. With the possible exception of isotonic fatigue time, there were no significant differences between the three treatment groups in compliance, physiologic sphincter strength, and clinical or quality-of-life measures. Correlations between physiologic measures and clinical outcomes were much stronger with ultrasound-based measures than with manometry. Although patients in this study who completed pelvic floor exercises with feedback from digital examination achieved no additional benefit from biofeedback and measurement with transanal ultrasound or manometry, it may be that the guidance received through digital examination alone offered patients in the pelvic floor exercise group an effective biofeedback mechanism. Contrary to our hypothesis, the use of transanal ultrasound offered no benefit over manometry, but the use of ultrasound for isotonic fatigue time and isometric fatigue contractions provided potentially important physiologic measures that require further study. This study has confirmed, through a large sample of patients, that pelvic floor retraining programs are an effective treatment for improving physiologic, clinical, and quality-of-life parameters in the short term.

  16. Detection of intracavitary uterine pathology using offline analysis of three-dimensional ultrasound volumes: interobserver agreement and diagnostic accuracy.

    PubMed

    Van den Bosch, T; Valentin, L; Van Schoubroeck, D; Luts, J; Bignardi, T; Condous, G; Epstein, E; Leone, F P; Testa, A C; Van Huffel, S; Bourne, T; Timmerman, D

    2012-10-01

    To estimate the diagnostic accuracy and interobserver agreement in predicting intracavitary uterine pathology at offline analysis of three-dimensional (3D) ultrasound volumes of the uterus. 3D volumes (unenhanced ultrasound and gel infusion sonography with and without power Doppler, i.e. four volumes per patient) of 75 women presenting with abnormal uterine bleeding at a 'bleeding clinic' were assessed offline by six examiners. The sonologists were asked to provide a tentative diagnosis. A histological diagnosis was obtained by hysteroscopy with biopsy or operative hysteroscopy. Proliferative, secretory or atrophic endometrium was classified as 'normal' histology; endometrial polyps, intracavitary myomas, endometrial hyperplasia and endometrial cancer were classified as 'abnormal' histology. The diagnostic accuracy of the six sonologists with regard to normal/abnormal histology and interobserver agreement were estimated. Intracavitary pathology was diagnosed at histology in 39% of patients. Agreement between the ultrasound diagnosis and the histological diagnosis (normal vs abnormal) ranged from 67 to 83% for the six sonologists. In 45% of cases all six examiners agreed with regard to the presence/absence of intracavitary pathology. The percentage agreement between any two examiners ranged from 65 to 91% (Cohen's κ, 0.31-0.81). The Schouten κ for all six examiners was 0.51 (95% CI, 0.40-0.62), while the highest Schouten κ for any three examiners was 0.69. When analyzing stored 3D ultrasound volumes, agreement between sonologists with regard to classifying the endometrium/uterine cavity as normal or abnormal as well as the diagnostic accuracy varied substantially. Possible actions to improve interobserver agreement and diagnostic accuracy include optimization of image quality and the use of a consistent technique for analyzing the 3D volumes. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  17. Ultrasound Findings on Hands and Wrists of Patients with Systemic Lupus Erythematosus: Relationship with Physical Examination.

    PubMed

    Lins, Carolina Freitas; Lima de Sá Ribeiro, Daniel; Dourado Santos, Willer Gonçalves; Rosa, Genevievi; Machicado, Viviane; Pedreira, Ana Luisa; Pimenta da Fonseca, Emanuela; Mota Duque Sousa, Anna Paula; Rodrigues Silva, Carla Baleeiro; Matos, Marcos Antonio Almeida; Santiago, Mittermayer Barreto

    2017-09-01

    Diagnosis of synovitis/tenosynovitis by physical examination can be difficult. Ultrasound (US) can be an effective tool for the evaluation of joint involvement in systemic lupus erythematosus (SLE). This study will describe musculoskeletal findings by US in SLE patients and the evaluation of their correlation with physical examination. SLE patients underwent clinical/sonographic evaluation of hand/wrists. In total, 896 joints were evaluated: at least 1 change on physical examination was found in 136 joints and at least 1 US abnormality was found in 65 of 896 joints. Out of the 65 joints with US changes, only 13 had findings on physical examination. Conversely, 111 joints had tenderness on physical examination with no sonographic abnormalities. Tenosynovitis was statistically significant more frequently with joint edema (41%) (p = 0.0003). US can detect musculoskeletal changes in only a minority of symptomatic SLE patients. Clinical findings may be related to some reasons that cannot be explained using US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Should a detailed ultrasound examination of the complete urinary tract be routinely performed in women with suspected pelvic endometriosis?

    PubMed

    Pateman, K; Holland, T K; Knez, J; Derdelis, G; Cutner, A; Saridogan, E; Jurkovic, D

    2015-12-01

    Is there any benefit to including the routine examination by ultrasound of the bladder, ureters and kidneys of women with endometriosis? The benefit of examination of the complete urinary tract of women with suspected endometriosis is that ureteric endometriosis, with or without hydronephrosis, can be detected which facilitates early intervention to prevent nephropathy. Women with endometriosis can get ureteric obstruction but there is no clear consensus on the correct diagnostic technique. Ultrasound is accurate at detecting women with bladder endometriosis but ureteric involvement has not been assessed previously. This was a prospective observational study, conducted at a teaching hospital over a period of 14 months. A total of 848 women presenting with chronic pelvic pain were included into the study. All women with chronic pelvic pain underwent a detailed transvaginal and transabdominal pelvic ultrasound examination to investigate possible causes of their symptoms. This included a systematic assessment of the urinary bladder, pelvic sections of the ureters and kidneys. The ultrasound findings were compared with findings at surgery and the results of targeted urological imaging and interventions. A total of 848 women presenting with chronic pelvic pain were included into the study. 28/848 women (3.3% 95% CI 2.1-4.5) had evidence of urinary tract abnormalities on initial ultrasound scan. Among these 17/848 (2.0% 95% CI 1.06-2.94) had evidence of urinary tract endometriosis, whilst 11/848 (1.3% 95% CI 0.54-2.06) women had other urinary tract abnormalities. Among women with urinary tract endometriosis 11/17 (65%) had evidence of ureteric involvement, 3/17 (18%) had both ureteric and bladder disease and 3/17 (18%) had bladder disease only. 12/17 (59%) women with urinary tract endometriosis also had evidence of hydronephrosis. The diagnosis of ureteral endometriosis had a sensitivity of 12/13 (92%) (95% CI 63.9-99.8), specificity 151/151 100% (95% CI 97.6-100), PPV 100% (95% CI 73.5-100), NPV 99.3% (95% CI 96.3-99.9%) LR- 0.08 (95% CI 0.01-0.39). The routine examination of the complete urinary tract including the distal ureters is a novel technique that should be evaluated in different populations. Ultrasound is an accurate test to diagnose urinary tract involvement in women with suspected pelvic endometriosis and examination of the complete urinary tract should become an integral part of ultrasound assessment of women with suspected endometriosis. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Thigh muscle and subcutaneous tissue thickness measured using ultrasound imaging in older females living in extended care: a preliminary study.

    PubMed

    Welch, Daniella; Ndanyo, Laetitia Sungu; Brown, Simon; Agyapong-Badu, Sandra; Warner, Martin; Stokes, Maria; Samuel, Dinesh

    2018-05-01

    Thigh tissue thickness has not been examined in older females living in extended care in UK as an indicator of musculoskeletal health. This study examined the feasibility of using ultrasound imaging to measure the thickness of superficial (fat) and deep layers (muscle) of the thigh in older females living in extended care. In ten older females in extended care (aged 80-98 years, mean 88 ± 6.8; body mass: 56.5 ± 12.6 kg) images of the anterior thigh (dominant) were taken in supine using B-mode ultrasound imaging. Superficial and deep layers were measured and percentage thickness was calculated. Independent t tests compared data from those in extended care to ten sedentary females living independently (aged 80-90 years, mean 84 ± 3.6; body mass: 61.6 ± 10.0 kg). Thickness of the superficial layers was not significantly different between the two groups (CI -0.017 to 0.815, p = 0.059). However, those living in extended care had greater (p < 0.001) muscle thickness (mean 2.75 ± 0.48 cm) than those living independently (mean 1.83 ± 0.3 cm), which was similarly significant when normalised for body mass (extended care 0.51 ± 0.16; independent living 0.30 ± 0.06). These novel findings showed it is feasible to use ultrasound to measure muscles in older females in extended care and that muscle thickness was larger than in those living independently. The reason for the difference seen between groups would need to be confirmed by a larger study that also examined factors related to risk of sarcopenia and frailty, such as nutrition and physical activity levels.

  20. Time to Add a Fifth Pillar to Bedside Physical Examination: Inspection, Palpation, Percussion, Auscultation, and Insonation.

    PubMed

    Narula, Jagat; Chandrashekhar, Y; Braunwald, Eugene

    2018-04-01

    Inspection, palpation, percussion, and auscultation have been the 4 pillars of clinical bedside medicine. Although these basic methods of physical examination have served us well, traditional bedside examination, for a number of reasons including diminishing interest and expertise, performs well less than what is required of a modern diagnostic strategy. Improving the performance of physical examination is vital given that it is crucial to guide diagnostic possibilities and further testing. Current efforts at improving physical examination skills during medical training have not been very successful, and incorporating appropriate technology at the bedside might improve its performance. Selective use of bedside ultrasound (or insonation) can be one such strategy that could be incorporated as the fifth component of the physical examination. Seeing pathology through imaging might improve interest in physical examination among trainees, and permit appropriate downstream testing and possibly superior decision making. Current ultrasound technology makes this feasible, and further miniaturization of ultrasound devices and reduced cost will allow for routine use at the bedside. It is time to have a wider debate and a possible consensus about updates required to enhance current paradigms of physical examination.

  1. Doppler ultrasound to detect pulpal blood flow changes during local anaesthesia.

    PubMed

    Yoon, M J; Lee, S J; Kim, E; Park, S H

    2012-01-01

      To examine whether Doppler ultrasound can detect changes in pulpal blood flow after infiltration anaesthesia.   Changes in pulpal blood flow in maxillary central incisor teeth of 18 patients (mean age 26.7 years, 13 men, five women) after infiltration anaesthesia were examined. Before infiltration anaesthesia, the pulpal blood flow was measured using Doppler ultrasound. A local anaesthetic solution containing 2% lidocaine with 1:80,000 epinephrine was injected into the submucosa above the experimental tooth. The Doppler ultrasound test was carried out at 5, 10, 20, 30, 45 and 60 min after infiltration. The parameters were Vas (maximum linear velocity, cm s(-1) ), Vam (average linear velocity, cm s(-1) ) and Vakd (minimum linear velocity, cm s(-1) ), which are indicators of the level of blood flow. The mixed procedure at the 95% confidence interval was used to examine the changes in pulpal blood flow after the injection.   The linear velocity profiles (Vas, Vam, and Vakd) decreased sharply 5 min after anaesthesia and then reduced continuously for 30 min. The maximum degree of blood flow reduction in Vas, Vam and Vakd was 58%, 83% and 82%, respectively. After 30 min, the linear velocities increased gradually. The Vam returned to the pre-anaesthesia state at 60 minutes but the Vas and Vakd did not recover completely.   Doppler ultrasound can detect changes in pulpal blood flow after infiltration anaesthesia. In the future, Doppler ultrasound can be used as a tool for measuring pulpal blood flow. © 2011 International Endodontic Journal.

  2. Virtual guidance as a tool to obtain diagnostic ultrasound for spaceflight and remote environments.

    PubMed

    Martin, David S; Caine, Timothy L; Matz, Timothy; Lee, Stuart M C; Stenger, Michael B; Sargsyan, Ashot E; Platts, Steven H

    2012-10-01

    With missions planned to travel greater distances from Earth at ranges that make real-time two-way communication impractical, astronauts will be required to perform autonomous medical diagnostic procedures during future exploration missions. Virtual guidance is a form of just-in-time training developed to allow novice ultrasound operators to acquire diagnostically-adequate images of clinically relevant anatomical structures using a prerecorded audio/visual tutorial viewed in real-time. Individuals without previous experience in ultrasound were recruited to perform carotid artery (N = 10) and ophthalmic (N = 9) ultrasound examinations using virtual guidance as their only training tool. In the carotid group, each untrained operator acquired two-dimensional, pulsed and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. Of the studies, 8 of the 10 carotid and 17 of 18 of the ophthalmic images (2 images collected per study) were judged to be diagnostically adequate. The quality of all but one of the ophthalmic images ranged from adequate to excellent. Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by previously untrained operators with assistance from only an audio/video tutorial viewed in real time while scanning. This form of just-in-time training, which can be applied to other examinations, represents an opportunity to acquire important information for NASA flight surgeons and researchers when trained medical personnel are not available or when remote guidance is impractical.

  3. A new instrument to assess physician skill at thoracic ultrasound, including pleural effusion markup.

    PubMed

    Salamonsen, Matthew; McGrath, David; Steiler, Geoff; Ware, Robert; Colt, Henri; Fielding, David

    2013-09-01

    To reduce complications and increase success, thoracic ultrasound is recommended to guide all chest drainage procedures. Despite this, no tools currently exist to assess proceduralist training or competence. This study aims to validate an instrument to assess physician skill at performing thoracic ultrasound, including effusion markup, and examine its validity. We developed an 11-domain, 100-point assessment sheet in line with British Thoracic Society guidelines: the Ultrasound-Guided Thoracentesis Skills and Tasks Assessment Test (UGSTAT). The test was used to assess 22 participants (eight novices, seven intermediates, seven advanced) on two occasions while performing thoracic ultrasound on a pleural effusion phantom. Each test was scored by two blinded expert examiners. Validity was examined by assessing the ability of the test to stratify participants according to expected skill level (analysis of variance) and demonstrating test-retest and intertester reproducibility by comparison of repeated scores (mean difference [95% CI] and paired t test) and the intraclass correlation coefficient. Mean scores for the novice, intermediate, and advanced groups were 49.3, 73.0, and 91.5 respectively, which were all significantly different (P < .0001). There were no significant differences between repeated scores. Procedural training on mannequins prior to unsupervised performance on patients is rapidly becoming the standard in medical education. This study has validated the UGSTAT, which can now be used to determine the adequacy of thoracic ultrasound training prior to clinical practice. It is likely that its role could be extended to live patients, providing a way to document ongoing procedural competence.

  4. [Physical principles and general considerations].

    PubMed

    Alfageme Roldán, F; Mollet Sánchez, J; Cerezo López, E

    2015-11-01

    Cutaneous ultrasound is based on the application of the physical properties of ultrasound to the skin and cutaneous adnexae. Knowledge of ultrasound semiology, artifacts and the application of Doppler examination allows deeper study of the biology and diseases of the skin and its adnexae. Copyright © 2015 Academia Española de Dermatología y Venereología. Published by Elsevier España, S.L.U. All rights reserved.

  5. Modeling cost of ultrasound versus nerve stimulator guidance for nerve blocks with sensitivity analysis.

    PubMed

    Liu, Spencer S; John, Raymond S

    2010-01-01

    Ultrasound guidance for regional anesthesia has increased in popularity. However, the cost of ultrasound versus nerve stimulator guidance is controversial, as multiple and varying cost inputs are involved. Sensitivity analysis allows modeling of different scenarios and determination of the relative importance of each cost input for a given scenario. We modeled cost per patient of ultrasound versus nerve stimulator using single-factor sensitivity analysis for 4 different clinical scenarios designed to span the expected financial impact of ultrasound guidance. The primary cost factors for ultrasound were revenue from billing for ultrasound (85% of variation in final cost), number of patients examined per ultrasound machine (10%), and block success rate (2.6%). In contrast, the most important input factors for nerve stimulator were the success rate of the nerve stimulator block (89%) and the amount of liability payout for failed airway due to rescue general anesthesia (9%). Depending on clinical scenario, ultrasound was either a profit or cost center. If revenue is generated, then ultrasound-guided blocks consistently become a profit center regardless of clinical scenario in our model. Without revenue, the clinical scenario dictates the cost of ultrasound. In an ambulatory setting, ultrasound is highly competitive with nerve stimulator and requires at least a 96% success rate with nerve stimulator before becoming more expensive. In a hospitalized scenario, ultrasound is consistently more expensive as the uniform use of general anesthesia and hospitalization negate any positive cost effects from greater efficiency with ultrasound.

  6. Are ultrasound-guided ophthalmic blocks injurious to the eye? A comparative rabbit model study of two ultrasound devices evaluating intraorbital thermal and structural changes.

    PubMed

    Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie

    2012-07-01

    Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1.5 minutes). A secondary analysis of temporal temperature differences between the orbital-rated and nonorbital transducers revealed statistically significant differences (Bonferroni-adjusted P < 0.05) in the cornea at 3.5 minutes, the lens at 2.5 minutes, and the vitreous at 4.0 minutes. Light microscopy and histology failed to elicit ocular injury in either group. The nonorbital-rated ultrasound machine (Sonosite Micromaxx) increases the ocular tissue temperature. A larger study is needed to establish safety. Until then, ophthalmic ultrasound-guided blocks should only be performed with ocular-rated devices.

  7. Are Ultrasound-Guided Ophthalmic Blocks Injurious to the Eye? A Comparative Rabbit Model Study of Two Ultrasound Devices Evaluating Intraorbital Thermal and Structural Changes

    PubMed Central

    Palte, Howard D.; Gayer, Steven; Arrieta, Esdras; Shaw, Eric Scot; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L.; Dubovy, Sander; Birnbach, David J.; Parel, Jean-Marie

    2012-01-01

    Background Since Atkinson’s original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The United States Food and Drug Administration have defined guidelines for safe use of ultrasound for ophthalmic examination but most ultrasound devices used by anesthesiologists are not Food and Drug Administration-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examination can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Methods Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital and non-orbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from two devices: 1) the Sonosite Micromaxx (non-orbital-rated) and 2) the Sonomed VuMax (orbital-rated) machines. In Phase I temperatures were continuously monitored via thermocouples implanted within specific eye structures (n=4). In Phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n=4). All eyes underwent light microscopy examinations followed, at different intervals, by histology evaluations conducted by an ophthalmic pathologist. Results Temperature changes were monitored in the eyes of four rabbits. The non-orbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases> 1.50C ) in the lens of three rabbits (at 5.0, 5.5 and 1.5 minutes) and cornea of two rabbits (both at 1.5 minutes). A secondary analysis of temporal temperature differences between the orbital-rated and non-orbital transducers revealed statistically significant differences (Bonferroni-adjusted p < 0.05) in the cornea at 3.5 minutes, the lens at 2.5 minutes and the vitreous at 4.0 minutes. Light microscopy and histology failed to elicit ocular injury in either group. Conclusions The non-orbital-rated ultrasound machine (Sonosite Micromaxx) increases the ocular tissue temperature. A larger study is needed to establish safety. Until then, ophthalmic blocks performed with ultrasound should be performed only with ocular-rated devices. PMID:22504211

  8. Fetal evaluation for transport by ultrasound performed by air medical teams: A case series.

    PubMed

    Polk, James D; Merlino, James I; Kovach, Betty L; Mancuso, Charlene; Fallon, William F

    2004-01-01

    The air medical team has limited options when evaluating the obstetrical patient and assessing fetal health during air transport to a high-risk obstetrical unit. Traditionally, physical examination and a Doppler stethoscope have been used to determine fetal heart rates and movement. However, with the advent of portable ultrasound technology, new information about the mother and child are available to the air medical crew. The Fetal Evaluation for Transport with Ultrasound (FETUS) is a screening examination that consists of an evaluation of the fetal heart rate, position, and movement and general condition of the placenta. The examination can be repeated in flight with no acoustic distortion from rotor noise. The additional information can be advantageous when transport decisions need to be made or when conditions do not allow Doppler stethoscope use.

  9. A resected perivascular epithelioid cell tumor (PEComa) of the pancreas diagnosed using endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Okuwaki, Kosuke; Kida, Mitsuhiro; Masutani, Hironori; Yamauchi, Hiroshi; Katagiri, Hiroyuki; Mikami, Tetuo; Miyazawa, Shiro; Iwai, Tomohisa; Takezawa, Miyoko; Imaizumi, Hiroshi; Koizumi, Wasaburo

    2013-01-01

    Primary perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare. We herein report our experience with a patient who had a primary PEComa of the pancreas that was diagnosed by the preoperative histopathological examination of a biopsy specimen obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). The patient was a 43-year-old woman whose chief complaint was abdominal pain. Imaging studies revealed a pancreatic tumor. Gastrointestinal stromal tumor (GIST), solid pseudopapillary tumor and neuroendocrine tumor were considered in the differential diagnosis. A histopathological examination of a specimen of the tumor obtained using EUS-FNA showed spindle-shaped tumor cells with enlarged nuclei and eosinophilic cytoplasm. The tumor cells proliferated in a sheet-like fashion and stained positive for the melanoma-associated antigen HMB-45. A PEComa was thus diagnosed. If an adequate tumor specimen can be obtained using EUS-FNA, immunostaining may facilitate the diagnosis of extremely rare diseases and therefore assist in deciding the treatment policy.

  10. Value of ultrasound shear wave elastography in the diagnosis of adenomyosis.

    PubMed

    Acar, S; Millar, E; Mitkova, M; Mitkov, V

    2016-11-01

    The aim of the study was to assess the accuracy of ultrasound shear wave elastography in the diagnosis of adenomyosis. One hundred and fifty three patients were examined. Ninety-seven patients were with suspected adenomyosis and 56 patients were with unremarkable myometrium. Adenomyosis was confirmed in 39 cases (A subgroup) and excluded in 14 cases (B subgroup) in the main group based on morphological examination. All patients underwent ultrasound examination using an Aixplorer (Supersonic Imagine, France) scanner with application of shear wave elastography during transvaginal scanning. Retrospective analysis of the elastography criteria against the findings from morphological/histological examination was performed. The following values of Young's modulus were found in subgroup A (adenomyosis): Emean - 72.7 (22.6-274.2) kPa (median, 5-95th percentiles), Emax - 94.8 (29.3-300.0) kPa, SD - 9.9 (2.6-26.3) kPa; in subgroup B (non adenomyosis) - 28.3 (12.7-59.5) kPa, 33.6 (16.0-80.8) kPa, 3.0 (1.4-15.6) kPa; in the control group - 24.4 (17.9-32.4) kPa, 29.8 (21.6-40.8) kPa, 2.3 (1.3-6.1) kPa, respectively (P < 0.05 for all comparison with subgroup В and the control group). The Emean cut-off value for adenomyosis diagnosis was 34.6 kPa. The sensitivity, specificity, positive predictive value, negative predictive value and area under curve (AUC) were 89.7%, 92.9%, 97.2%, 76.5% and 0.908. The Emax cut-off value was 45.4 kPa (89.7%, 92.9%, 97.2%, 76.5% and 0.907, respectively). This study showed a significant increase of the myometrial stiffness estimated with shear wave elastography use in patients with adenomyosis.

  11. Does Maternal Body Mass Index Have an Effect on the Accuracy of Ultrasound-Derived Estimated Birth Weight?: A Retrospective Study.

    PubMed

    Gonzalez, Maritza G; Reed, Kathryn L; Center, Katherine E; Hill, Meghan G

    2017-05-01

    The purpose of this study was to investigate the relationship between the maternal body mass index (BMI) and the accuracy of ultrasound-derived birth weight. A retrospective chart review was performed on women who had an ultrasound examination between 36 and 43 weeks' gestation and had complete delivery data available through electronic medical records. The ultrasound-derived fetal weight was adjusted by 30 g per day of gestation that elapsed between the ultrasound examination and delivery to arrive at the predicted birth weight. A total of 403 pregnant women met inclusion criteria. Age ranged from 13-44 years (mean ± SD, 28.38 ± 5.97 years). The mean BMI was 32.62 ± 8.59 kg/m 2 . Most of the women did not have diabetes (n = 300 [74.0%]). The sample was primarily white (n = 165 [40.9%]) and Hispanic (n = 147 [36.5%]). The predicted weight of neonates at delivery (3677.07 ± 540.51 g) was higher than the actual birth weight (3335.92 ± 585.46 g). Based on regression analyses, as the BMI increased, so did the predicted weight (P < .01) and weight at delivery (P < .01). The accuracy of the estimated ultrasound-derived birth weight was not predicted by the maternal BMI (P = .22). Maternal race and diabetes status were not associated with the accuracy of ultrasound in predicting birth weight. Both predicted and actual birth weight increased as the BMI increased. However, the BMI did not affect the accuracy of the estimated ultrasound-derived birth weight. Maternal race and diabetes status did not influence the accuracy of the ultrasound-derived predicted birth weight. © 2017 by the American Institute of Ultrasound in Medicine.

  12. Ultrasound Stimulation of Insulin Release from Pancreatic Beta Cells

    NASA Astrophysics Data System (ADS)

    Suarez Castellanos, Ivan M.

    Type 2 diabetes (T2D) mellitus is a complex metabolic disease that has reached epidemic proportions in the United States and around the world. Controlling T2D is often difficult as pharmacological management routinely requires complex therapy with multiple medications, and loses its effectiveness over time. The objective of this dissertation was to explore a novel, non-pharmacological approach that utilizes the application of ultrasound energy to stimulate insulin release. Our experiments have focused on determination of effectiveness and safety of ultrasound application in stimulation of insulin release from the pancreatic beta cells. Our results showed that ultrasound treatment, applied at frequencies of 800 kHz and 1 MHz and intensities of 0.5 W/cm2 and 1 W/cm2, did not produce any significant effects on cell viability compared to sham group as assessed with trypan blue dye exclusion test and MTT cytotoxicity assay. ELISA quantification of insulin release from beta cells resulting from ultrasound treatment showed clinically-significant amounts of released insulin as compared to sham-treated beta cells. Carbon fiber amperometry detection of secretory events from dopamine-loaded beta cells treated with ultrasound showed that release of secretory content could be temporally controlled by careful selection of ultrasound parameters. Both ELISA and amperometry experiments demonstrated that ultrasound-stimulated insulin release is a calcium-dependent process, potentially mediated by the mechanical effects of ultrasound. This study demonstrated that therapeutic ultrasound is a technique capable of stimulating the release of insulin from pancreatic beta cells in a safe, effective and controlled manner.

  13. Utility of 3-dimensional ultrasound imaging to evaluate carotid artery stenosis: comparison with magnetic resonance angiography.

    PubMed

    Igase, Keiji; Kumon, Yoshiaki; Matsubara, Ichiro; Arai, Masamori; Goishi, Junji; Watanabe, Hideaki; Ohnishi, Takanori; Sadamoto, Kazuhiko

    2015-01-01

    We evaluated the utility of 3-dimensional (3-D) ultrasound imaging for assessment of carotid artery stenosis, as compared with similar assessment via magnetic resonance angiography (MRA). Subjects comprised 58 patients with carotid stenosis who underwent both 3-D ultrasound imaging and MRA. We studied whether abnormal findings detected by ultrasound imaging could be diagnosed using MRA. Ultrasound images were generated using Voluson 730 Expert and Voluson E8. The degree of stenosis was mild in 17, moderate in 16, and severe in 25 patients, according to ultrasound imaging. Stenosis could not be recognized using MRA in 4 of 17 patients diagnosed with mild stenosis using ultrasound imaging. Ultrasound imaging showed ulceration in 13 patients and mobile plaque in 6 patients. When assessing these patients, MRA showed ulceration in only 2 of 13 patients and did not detect mobile plaque in any of these 6 patients. Static 3-D B mode images demonstrated distributions of plaque, ulceration, and mobile plaque, and static 3-D flow images showed flow configuration as a total structure. Real-time 3-D B mode images demonstrated plaque and vessel movement. Carotid artery stenting was not selected for patients diagnosed with ulceration or mobile plaque. Ultrasound imaging was necessary to detect mild stenosis, ulcerated plaque, or mobile plaque in comparison with MRA, and 3-D ultrasound imaging was useful to recognize carotid stenosis and flow pattern as a total structure by static and real-time 3-D demonstration. This information may contribute to surgical planning. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Comparison of clinical marking and ultrasound-guided injection of Botulinum type A toxin into the masseter muscles for treating bruxism and its cosmetic effects.

    PubMed

    Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo

    2016-09-01

    Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.

  15. Ultrasound of the Brachial Plexus.

    PubMed

    Griffith, James F

    2018-07-01

    Examination of the brachial plexus with ultrasound is efficient because it allows many parts of the brachial plexus as well as the surrounding soft tissues to be assessed with high spatial resolution. The key to performing good ultrasound of the brachial plexus is being familiar with the anatomy and the common variants. That makes it possible to concentrate solely on the ultrasound appearances free of simultaneously wondering about the anatomy. Ultrasound of the brachial plexus is particularly good for assessing nerve sheath tumor, perineural fibrosis, metastases, some inflammatory neuropathies, neuralgic amyotrophy, and posttraumatic sequalae. It is limited in the assessment of thoracic outlet syndrome and in the acute/subacute trauma setting. This review addresses the anatomy, ultrasound technique, as well as pathology of the brachial plexus from the cervical foramina to the axilla. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Low-Frequency Ultrasound Debridement in Chronic Wound Healing: A Systematic Review of Current Evidence

    PubMed Central

    Chang, Ying-Ju Ruby; Perry, Julie

    2017-01-01

    Chronic wounds are painful and debilitating to patients, pose a clinical challenge to physicians, and impose financial burden on the health-care system. New treatment options are therefore highly sought after. Ultrasound debridement is a promising technology that functions to disperse bacterial biofilms and stimulate wound healing. In this review, we focus on low-frequency ultrasound (20-60 kHz) and summarize the findings of 25 recent studies examining ultrasound efficacy. Ultrasound debridement appears to be most effective when used 3 times a week and has the potential to decrease exudate and slough, decrease patient pain, disperse biofilms, and increase healing in wounds of various etiology. Although current studies are generally of smaller size, the results are promising and we recommend the testing of low-frequency ultrasound therapy in clinical practice on a larger scale. PMID:29026808

  17. Local binary pattern texture-based classification of solid masses in ultrasound breast images

    NASA Astrophysics Data System (ADS)

    Matsumoto, Monica M. S.; Sehgal, Chandra M.; Udupa, Jayaram K.

    2012-03-01

    Breast cancer is one of the leading causes of cancer mortality among women. Ultrasound examination can be used to assess breast masses, complementarily to mammography. Ultrasound images reveal tissue information in its echoic patterns. Therefore, pattern recognition techniques can facilitate classification of lesions and thereby reduce the number of unnecessary biopsies. Our hypothesis was that image texture features on the boundary of a lesion and its vicinity can be used to classify masses. We have used intensity-independent and rotation-invariant texture features, known as Local Binary Patterns (LBP). The classifier selected was K-nearest neighbors. Our breast ultrasound image database consisted of 100 patient images (50 benign and 50 malignant cases). The determination of whether the mass was benign or malignant was done through biopsy and pathology assessment. The training set consisted of sixty images, randomly chosen from the database of 100 patients. The testing set consisted of forty images to be classified. The results with a multi-fold cross validation of 100 iterations produced a robust evaluation. The highest performance was observed for feature LBP with 24 symmetrically distributed neighbors over a circle of radius 3 (LBP24,3) with an accuracy rate of 81.0%. We also investigated an approach with a score of malignancy assigned to the images in the test set. This approach provided an ROC curve with Az of 0.803. The analysis of texture features over the boundary of solid masses showed promise for malignancy classification in ultrasound breast images.

  18. Quantitative ultrasound method for assessing stress-strain properties and the cross-sectional area of Achilles tendon

    NASA Astrophysics Data System (ADS)

    Du, Yi-Chun; Chen, Yung-Fu; Li, Chien-Ming; Lin, Chia-Hung; Yang, Chia-En; Wu, Jian-Xing; Chen, Tainsong

    2013-12-01

    The Achilles tendon is one of the most commonly observed tendons injured with a variety of causes, such as trauma, overuse and degeneration, in the human body. Rupture and tendinosis are relatively common for this strong tendon. Stress-strain properties and shape change are important biomechanical properties of the tendon to assess surgical repair or healing progress. Currently, there are rather limited non-invasive methods available for precisely quantifying the in vivo biomechanical properties of the tendons. The aim of this study was to apply quantitative ultrasound (QUS) methods, including ultrasonic attenuation and speed of sound (SOS), to investigate porcine tendons in different stress-strain conditions. In order to find a reliable method to evaluate the change of tendon shape, ultrasound measurement was also utilized for measuring tendon thickness and compared with the change in tendon cross-sectional area under different stress. A total of 15 porcine tendons of hind trotters were examined. The test results show that the attenuation and broadband ultrasound attenuation decreased and the SOS increased by a smaller magnitude as the uniaxial loading of the stress-strain upon tendons increased. Furthermore, the tendon thickness measured with the ultrasound method was significantly correlated with tendon cross-sectional area (Pearson coefficient = 0.86). These results also indicate that attenuation of QUS and ultrasonic thickness measurement are reliable and potential parameters for assessing biomechanical properties of tendons. Further investigations are needed to warrant the application of the proposed method in a clinical setting.

  19. Ultrasound-guided stellate ganglion blocks combined with pharmacological and occupational therapy in Complex Regional Pain Syndrome (CRPS): a pilot case series ad interim.

    PubMed

    Wei, Karin; Feldmann, Robert E; Brascher, Anne-Kathrin; Benrath, Justus

    2014-12-01

    This preliminary and retrospective pilot case series examines a treatment concept consisting of ultrasound-guided stellate ganglion blocks (SGBs) combined with pharmacological and occupational therapy in patients with complex regional pain syndrome (CRPS) of the hand. Efficacy of combined treatment concepts and safety of ultrasound-guided SGB have not been sufficiently investigated yet. A total number of 156 blocks were evaluated in 16 patients with CRPS in a retrospective analysis. All patients received pharmacotherapy and a standard regimen of occupational therapy offered simultaneously to the SGBs. Changes in both spontaneous and evoked pain levels were assessed by numerical pain rating score before and after the last blockade of a series. Side effects were documented. The overall mean pain reduction was 63.2% regarding spontaneous and 45.3% regarding evoked pain. Mild complications, such as hoarseness or dysphagia, occurred in 13.5% of the blocks (21 SGBs). Serious complications, such as plexus paresis or accidental puncture of vessels or other structures, did not occur. Time between symptom onset and start of treatment did not affect the extent of pain reduction. The combination of ultrasound-guided SGB and simultaneous pharmacological and occupational therapy showed encouraging treatment results under conditions of this pilot case series. Assessment of efficacy of this combined treatment concept and safety of ultrasound-guided SGB require further prospective clinical studies with larger number of participants. Wiley Periodicals, Inc.

  20. Ultrasound neuro-modulation chip: activation of sensory neurons in Caenorhabditis elegans by surface acoustic waves.

    PubMed

    Zhou, Wei; Wang, Jingjing; Wang, Kaiyue; Huang, Bin; Niu, Lili; Li, Fei; Cai, Feiyan; Chen, Yan; Liu, Xin; Zhang, Xiaoyan; Cheng, Hankui; Kang, Lijun; Meng, Long; Zheng, Hairong

    2017-05-16

    Ultrasound neuro-modulation has gained increasing attention as a non-invasive method. In this paper, we present an ultrasound neuro-modulation chip, capable of initiating reversal behaviour and activating neurons of C. elegans under the stimulation of a single-shot, short-pulsed ultrasound. About 85.29% ± 6.17% of worms respond to the ultrasound stimulation exhibiting reversal behaviour. Furthermore, the worms can adapt to the ultrasound stimulation with a lower acoustic pulse duration of stimulation. In vivo calcium imaging shows that the activity of ASH, a polymodal sensory neuron in C. elegans, can be directly evoked by the ultrasound stimulation. On the other hand, AFD, a thermal sensitive neuron, cannot be activated by the ultrasound stimulation using the same parameter and the temperature elevation during the stimulation process is relatively small. Consistent with the calcium imaging results, the tax-4 mutants, which are insensitive to temperature increase, do not show a significant difference in avoidance probability compared to the wild type. Therefore, the mechanical effects induced by ultrasound are the main reason for neural and behavioural modulation of C. elegans. With the advantages of confined acoustic energy on the surface, compatible with standard calcium imaging, this neuro-modulation chip could be a powerful tool for revealing the molecular mechanisms of ultrasound neuro-modulation.

  1. Ultrasonic atomization of tissue and its role in tissue fractionation by high intensity focused ultrasound

    PubMed Central

    Simon, Julianna C.; Sapozhnikov, Oleg A.; Khokhlova, Vera A.; Wang, Yak-Nam; Crum, Lawrence A.; Bailey, Michael R.

    2012-01-01

    Atomization and fountain formation is a well-known phenomenon that occurs when a focused ultrasound wave in liquid encounters an air interface. High intensity focused ultrasound (HIFU) has been shown to fractionate tissue into submicron-size fragments in a process termed boiling histotripsy, wherein the focused ultrasound wave superheats the tissue at the focus, producing a millimetre-size boiling or vapour bubble in several milliseconds. Yet the question of how this millimetre-size boiling bubble creates submicron-size tissue fragments remains. The hypothesis of this work is that tissue can behave as a liquid such that it forms a fountain and atomization within the vapour bubble produced in boiling histotripsy. We describe an experiment, in which a 2-MHz HIFU transducer (maximum in situ intensity of 24,000 W/cm2) was aligned with an air-tissue interface meant to simulate the boiling bubble. Atomization and fountain formation were observed with high-speed photography and resulted in tissue erosion. Histological examination of the atomized tissue showed whole and fragmented cells and nuclei. Air-liquid interfaces were also filmed. Our conclusion was that HIFU can fountain and atomize tissue. Although this process does not entirely mimic what was observed in liquids, it does explain many aspects of tissue fractionation in boiling histotripsy. PMID:23159812

  2. Influence of extracellular polymeric substances (EPS) treated by combined ultrasound pretreatment and chemical re-flocculation on water treatment sludge settling performance.

    PubMed

    Chen, Wei; Gao, Xiaohong; Xu, Hang; Cai, Yan; Cui, Jianfeng

    2017-03-01

    Extracellular polymeric substances (EPS) are high molecular weight polymers and play a significant role in floc stability, floc size, bioflocculation and sludge settleability. The destruction and reconstruction of EPS improve the performance of solid-water separation processes. In this study, the influence of combined ultrasound pretreatment and chemical re-flocculation on the spatial distribution and composition of EPS was examined. Settleability efficiency demonstrated that the optimal operating condition was an ultrasound pretreatment time of 15 min at pH 6. Sludge particles were greatly disintegrated and the protein-like substances were converted into smaller molecules after ultrasound treatment, and pH had important effects on solubilization and degradation of protein-like substances. The flocs of sludge water after addition of polyacrylamide were larger in size and denser in structure than those resulting from addition of polyaluminium chloride. However, polyaluminium chloride had a better capacity for degrading EPS, especially at a dosage of 1.2 g/g total suspended solids. The results of this research show that the combination of ultrasonication and chemical re-flocculation is effective in treating sludge water from a drinking water treatment plant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Using trainable segmentation and watershed transform for identifying unilocular and multilocular cysts from ultrasound images of ovarian tumour

    NASA Astrophysics Data System (ADS)

    Ibrahim, Dheyaa Ahmed; Al-Assam, Hisham; Du, Hongbo; Jassim, Sabah

    2017-05-01

    Ovarian masses are categorised into different types of malignant and benign. In order to optimize patient treatment, it is necessary to carry out pre-operational characterisation of the suspect ovarian mass to determine its category. Ultrasound imaging has been widely used in differentiating malignant from benign cases due to its safe and non-intrusive nature, and can be used for determining the number of cysts in the ovary. Presently, the gynaecologist is tasked with manually counting the number of cysts shown on the ultrasound image. This paper proposes, a new approach that automatically segments the ovarian masses and cysts from a static B-mode image. Initially, the method uses a trainable segmentation procedure and a trained neural network classifier to accurately identify the position of the masses and cysts. After that, the borders of the masses can be appraised using watershed transform. The effectiveness of the proposed method has been tested by comparing the number of cysts identified by the method against the manual examination by a gynaecologist. A total of 65 ultrasound images were used for the comparison, and the results showed that the proposed solution is a viable alternative to the manual counting method for accurately determining the number of cysts in a US ovarian image.

  4. FINAL INTERIM REPORT, CANDIDATE SITES, MACHINES IN USE, DATA STORAGE AND TRANSMISSION METHODS: TESTING FEASIBILITY OF 3D ULTRASOUND DATA ACQUISITION AND RELIABILITY OF DATA RETRIEVAL FROM STORED 3D IMAGES

    EPA Science Inventory

    The purpose of this Work Assignment, 02-03, is to examine the feasibility of collecting transmitting, and analyzing 3-D ultrasound data in the context of a multi-center study of pregnant women. The study will also examine the reliability of measurements obtained from 3-D images< ...

  5. Use of eddy current mixes to solve a weld examination application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, R.C.; LaBoissonniere, A.

    1995-12-31

    The augmentation of typical nondestructive (i.e., ultrasound) weld inspection techniques by the use of eddy current tools may significantly enhance the quality and reliability of weld inspections. One recent example is the development of an eddy current technique for use in the examination of BWR core shroud welds, where multi-frequency mixes are used to eliminate signals coming from the weld material so that the examination of the heat affected zone is enhanced. An analysis tool most commonly associated with ultrasound examinations, the C-Scan based on gated information, may be implemented with eddy current data to enhance analysis.

  6. Musculoskeletal ultrasound in rheumatology in Korea: targeted ultrasound initiative survey.

    PubMed

    Kang, Taeyoung; Wakefield, Richard J; Emery, Paul

    2016-04-01

    In collaboration with the Targeted Ultrasound Initiative (TUI), to conduct the first study in Korea to investigate current practices in ultrasound use among Korean rheumatologists. We translated the TUI Global Survey into Korean and added questions to better understand the specific challenges facing rheumatologists in Korea. To target as many rheumatologists in Korea as possible, we created an on-line version of this survey, which was conducted from March to April 2013. Rheumatologists are in charge of ultrasound in many Korean hospitals. Rheumatologists in hospitals and private clinics use ultrasound to examine between one and five patients daily; they use ultrasound for diagnosis more than monitoring and receive compensation of about US$30-50 per patient. There are marked differences in the rates of ultrasound usage between rheumatologists who work in private practice compared with tertiary hospitals. Korean rheumatologists not currently using ultrasound in their practice appear eager to do so. This survey provides important insights into the current status of ultrasound in rheumatology in Korea and highlights several priorities; specifically, greater provision of formal training, standardization of reporting and accrual of greater experience among ultrasound users. If these needs are addressed, all rheumatology departments in Korea are likely to use ultrasound or have access to it in the future. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  7. Diagnostic Imaging of the Hepatobiliary System: An Update.

    PubMed

    Marolf, Angela J

    2017-05-01

    Recent advances in diagnostic imaging of the hepatobiliary system include MRI, computed tomography (CT), contrast-enhanced ultrasound, and ultrasound elastography. With the advent of multislice CT scanners, sedated examinations in veterinary patients are feasible, increasing the utility of this imaging modality. CT and MRI provide additional information for dogs and cats with hepatobiliary diseases due to lack of superimposition of structures, operator dependence, and through intravenous contrast administration. Advanced ultrasound methods can offer complementary information to standard ultrasound imaging. These newer imaging modalities assist clinicians by aiding diagnosis, prognostication, and surgical planning. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Ultrasound of the Thyroid Gland

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... has substantially grown over time Because ultrasound provides real-time images, images that are renewed continuously, it also ...

  9. Cranial Ultrasound/Head Ultrasound

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... by a computer, which in turn creates a real-time picture on the monitor. One or more frames ...

  10. Simulation Study of Effects of the Blind Deconvolution on Ultrasound Image

    NASA Astrophysics Data System (ADS)

    He, Xingwu; You, Junchen

    2018-03-01

    Ultrasonic image restoration is an essential subject in Medical Ultrasound Imaging. However, without enough and precise system knowledge, some traditional image restoration methods based on the system prior knowledge often fail to improve the image quality. In this paper, we use the simulated ultrasound image to find the effectiveness of the blind deconvolution method for ultrasound image restoration. Experimental results demonstrate that the blind deconvolution method can be applied to the ultrasound image restoration and achieve the satisfactory restoration results without the precise prior knowledge, compared with the traditional image restoration method. And with the inaccurate small initial PSF, the results shows blind deconvolution could improve the overall image quality of ultrasound images, like much better SNR and image resolution, and also show the time consumption of these methods. it has no significant increasing on GPU platform.

  11. High Energy Ultrasound As An Applicable Tool For Well Regeneration

    NASA Astrophysics Data System (ADS)

    Bott, W.; Hofmann, T.; Wilken, R.-D.

    Drinking water abstraction by groundwater wells is a main part of ground-water man- agement. During well operation ageing processes cause a decrease of permeability and productivity of these wells. The occurring processes are mainly a combination of chemical, physical and biological factors. This leads to the necessity of well regen- eration in order to maintain original well conditions and are linked to major invest- ments. The use of ultrasound as a well regeneration method is a new application for this purpose. In comparison to conventional regeneration methods, mainly mechan- ical and chemical procedures or a combination of both, high energy ultrasound can be called an environmentally "friendly" application because of the avoidance of any use of harmful chemicals within the well and the aquifer. In addition this method acts with consideration to the well building. But there are conflicting opinions on the effi- ciency of ultrasound. The goal of a current research project, financed by the German Foundation of Environment (DBU), is to answer the question, under which conditions high energy ultrasound is most effective for well regeneration. For this purpose an experimental station was constructed to carry out laboratory examinations on the in- fluence of different parameters on ultrasound efficiency, i.e. hydrostatic pressure, tem- perature, different filter gravel and well filter, duration of sonic, fre-quency and inten- sity. The whole instal-lation is stable regarding pressure up to 20 bar, to approximate con-ditions in real wells. First results show a clear dependence of sonic penetration on different materials of well filter and different size of filter gravel as well as on hydro- static pressure conditions within the well. The contribution presents the experimental setup and figures out further results of currently carried out investigations.

  12. Ultrasound-enhanced bioscouring of greige cotton: regression analysis of process factors

    USDA-ARS?s Scientific Manuscript database

    Ultrasound-enhanced bioscouring process factors for greige cotton fabric are examined using custom experimental design utilizing statistical principles. An equation is presented which predicts bioscouring performance based upon percent reflectance values obtained from UV-Vis measurements of rutheniu...

  13. Cost Analysis of Following Up Incomplete Low-Risk Fetal Anatomy Ultrasounds.

    PubMed

    O'Brien, Karen; Shainker, Scott A; Modest, Anna M; Spiel, Melissa H; Resetkova, Nina; Shah, Neel; Hacker, Michele R

    2017-03-01

    To examine the clinical utility and cost of follow-up ultrasounds performed as a result of suboptimal views at the time of initial second-trimester ultrasound in a cohort of low-risk pregnant women. We conducted a retrospective cohort study of women at low risk for fetal structural anomalies who had second-trimester ultrasounds at 16 to less than 24 weeks of gestation from 2011 to 2013. We determined the probability of women having follow-up ultrasounds as a result of suboptimal views at the time of the initial second-trimester ultrasound, and calculated the probability of detecting an anomaly on follow-up ultrasound. These probabilities were used to estimate the national cost of our current ultrasound practice, and the cost to identify one fetal anomaly on follow-up ultrasound. During the study period, 1,752 women met inclusion criteria. Four fetuses (0.23% [95% CI 0.06-0.58]) were found to have anomalies at the initial ultrasound. Because of suboptimal views, 205 women (11.7%) returned for a follow-up ultrasound, and one (0.49% [95% CI 0.01-2.7]) anomaly was detected. Two women (0.11%) still had suboptimal views and returned for an additional follow-up ultrasound, with no anomalies detected. When the incidence of incomplete ultrasounds was applied to a similar low-risk national cohort, the annual cost of these follow-up scans was estimated at $85,457,160. In our cohort, the cost to detect an anomaly on follow-up ultrasound was approximately $55,000. The clinical yield of performing follow-up ultrasounds because of suboptimal views on low-risk second-trimester ultrasounds is low. Since so few fetal abnormalities were identified on follow-up scans, this added cost and patient burden may not be warranted. © 2016 Wiley Periodicals, Inc.

  14. The Endoplasmic Reticulum Stress Protein Calreticulin in Diabetic Chronic Kidney Disease

    DTIC Science & Technology

    2015-07-01

    lines and for use in long-term assays. For aim 2, we established that 0.7 mPa of ultrasound to deliver cre- recombinase plasmid to the kidney is...using kidney targeted microbubble/ ultrasound -mediated plasmid delivery. We will also examine non-targeted CRT knockdown in these mice. Aim 2.b: We will...diabetes, chronic kidney disease, diabetic nephropathy, calreticulin, TGF-beta, ER stress, ultrasound , tubulointerstitial fibrosis 4 3. ACCOMPLISHMENTS a

  15. Color-coded perfusion analysis of CEUS for pre-interventional diagnosis of microvascularisation in cases of vascular malformations.

    PubMed

    Teusch, V I; Wohlgemuth, W A; Piehler, A P; Jung, E M

    2014-01-01

    Aim of our pilot study was the application of a contrast-enhanced color-coded ultrasound perfusion analysis in patients with vascular malformations to quantify microcirculatory alterations. 28 patients (16 female, 12 male, mean age 24.9 years) with high flow (n = 6) or slow-flow (n = 22) malformations were analyzed before intervention. An experienced examiner performed a color-coded Doppler sonography (CCDS) and a Power Doppler as well as a contrast-enhanced ultrasound after intravenous bolus injection of 1 - 2.4 ml of a second-generation ultrasound contrast medium (SonoVue®, Bracco, Milan). The contrast-enhanced examination was documented as a cine sequence over 60 s. The quantitative analysis based on color-coded contrast-enhanced ultrasound (CEUS) images included percentage peak enhancement (%peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT). No side effects occurred after intravenous contrast injection. The mean %peak in arteriovenous malformations was almost twice as high as in slow-flow-malformations. The area under the curve was 4 times higher in arteriovenous malformations compared to the mean value of other malformations. The mean transit time was 1.4 times higher in high-flow-malformations compared to slow-flow-malformations. There was no difference regarding the time to peak between the different malformation types. The comparison between all vascular malformation and surrounding tissue showed statistically significant differences for all analyzed data (%peak, TTP, AUC, MTT; p < 0.01). High-flow and slow-flow vascular malformations had statistically significant differences in %peak (p < 0.01), AUC analysis (p < 0.01), and MTT (p < 0.05). Color-coded perfusion analysis of CEUS seems to be a promising technique for the dynamic assessment of microvasculature in vascular malformations.

  16. The role of tridimensional dynamic ultrasound for pelvic floor evaluation.

    PubMed

    de la Portilla, Fernando; Rubio Manzanares Dorado, Mercedes; Pino Díaz, Verónica; Vazquez Monchul, Jorge M; Palacios, Carmen; Díaz Pavón, José M; Sánchez Gil, José M; García Cabrera, Ana María

    2015-10-01

    Dynamic endoanal ultrasound has emerged in recent years as a test that could replace the now existing tests in the diagnosis of pelvic floor disorders. The aim of this paper is to determine the usefulness of echodefecography in the diagnosis and evaluation of patients with symptoms of anorrectal obstruction, and show the results obtained after its implementation in a pelvic floor unit, as a complementary tool that could replace conventional defecography. In this retrospective study we analyzed 66 patients with a mean age of 55 years (19-83), 61 women (92%). All dynamic ultrasound was performed in 3 dimensions and was correlated with symptoms and physical findings in the consultation. A descriptive and inferential study was performed to find a kappa correlation between physical examination and echodefecography. The reasons for consultation were: Anorrectal obstruction syndrome 36 patients (54.5%), pelvic organ prolapse 27 patients (40.9%), and anorrectal obstruction syndrome along with pelvic organ prolapse 3 patients (4.5%). The correlation of the 2 groups indicated that echodefecography diagnosed more patients with grade III rectocele, enteroceles, and anismus than the combination of scan-ultrasound-manometry-proctoscopy (Kappa 0.26, 0.38 and 0.21, 95% CI: from 0,07 to 1.00, 0.15 to 1.00 and from 0.12 to 1.00, respectively) (P<.001). Conversely, echodefecography diagnosed less perineal descense (Kappa 0.28, 95% CI: 0.12 to 1.00). Dynamic anal ultrasonography may have a role as a complementary test in patients with pelvic floor disorders, achieving diagnoses that would go undetected by inspection, physical examination and manometry. Copyright © 2014 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Contrast-enhanced ultrasound in diagnosis of gallbladder adenoma.

    PubMed

    Yuan, Hai-Xia; Cao, Jia-Ying; Kong, Wen-Tao; Xia, Han-Sheng; Wang, Xi; Wang, Wen-Ping

    2015-04-01

    Gallbladder adenoma is a pre-cancerous neoplasm and needs surgical resection. It is difficult to differentiate adenoma from other gallbladder polyps using imaging examinations. The study aimed to illustrate characteristics of contrast-enhanced ultrasound (CEUS) and its diagnostic value in gallbladder adenoma. Thirty-seven patients with 39 gallbladder adenomatoid lesions (maximal diameter ≥10 mm and without metastasis) were enrolled in this study. Lesion appearances in conventional ultrasound and CEUS were documented. The imaging features were compared individually among gallbladder cholesterol polyp, gallbladder adenoma and malignant lesion. Adenoma lesions showed iso-echogenicity in ultrasound, and an eccentric enhancement pattern, "fast-in and synchronous-out" contrast enhancement pattern and homogeneous at peak-time enhancement in CEUS. The homogenicity at peak-time enhancement showed the highest diagnostic ability in differentiating gallbladder adenoma from cholesterol polyps. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy and Youden index were 100%, 90.9%, 92.9%, 100%, 95.8% and 0.91, respectively. The characteristic of continuous gallbladder wall shown by CEUS had the highest diagnostic ability in differentiating adenoma from malignant lesion (100%, 86.7%, 86.7%, 100%, 92.9% and 0.87, respectively). The characteristic of the eccentric enhancement pattern had the highest diagnostic ability in differentiating adenoma from cholesterol polyp and malignant lesion, with corresponding indices of 69.2%, 88.5%, 75.0%, 85.2%, 82.1% and 0.58, respectively. CEUS is valuable in differentiating gallbladder adenoma from other gallbladder polyps (≥10 mm in diameter). Homogeneous echogenicity on peak-time enhancement, a continuous gallbladder wall, and the eccentric enhancement pattern are important indicators of gallbladder adenoma on CEUS.

  18. Critical Care Ultrasound: A Review for Practicing Nephrologists.

    PubMed

    Wilson, Jennifer G; Breyer, Kristine E W

    2016-05-01

    The use of point-of-care ultrasound in the intensive care unit, both for diagnostic and procedural purposes, has rapidly proliferated, and evidence supporting its use is growing. Conceptually, critical care ultrasound (CCUS) should be considered an extension of the physical examination and should not be considered a replacement for formal echocardiography or radiology-performed ultrasound. Several CCUS applications are of particular relevance to nephrologists, including focused renal ultrasound in patients at high risk for urinary tract obstruction, real-time ultrasound guidance and verification during the placement of central venous catheters, and ultrasound-augmented assessment of shock and volume status. Each of these applications has the capacity to improve outcomes in patients with acute kidney injury. Although robust evidence regarding long-term outcomes is lacking, existing data demonstrate that CCUS has the potential to improve diagnostic accuracy, expedite appropriate management, and increase safety for critically ill patients across a spectrum of pathologies. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  19. A comparison between the patella and the calcaneus using ultrasound velocity and attenuation as predictors of bone mineral density

    NASA Astrophysics Data System (ADS)

    Han, S. M.; Davis, J.

    1997-10-01

    The bone mineral density (BMD), ultrasound velocity (UV) and attenuation were examined in sixteen matched sets of human patellae and calcanei. For the sixteen calcanei, BMD was strongly correlated with all ultrasound parameters. Calcaneal UV appeared to be inferior to attenuation in the ability to predict BMD. For the sixteen patellae, the average UV was found to be greater in the superior/inferior direction than in the anterior/posterior and medial/lateral directions. It was found that patella BMD was significantly correlated with each of three directional ultrasound velocities. The relationship between BMD and ultrasound attenuation parameters was not significant in the patella. A comparative study of the two different bone sets demonstrated that the BMDs of the patella and calcaneus were significantly correlated with each other. Ultrasound velocity of calcaneus, measured in the medial/lateral direction, was not significantly associated with any of three directional ultrasound velocities in the patella. Similarly, ultrasound attenuation parameters of calcaneus were not significantly correlated with those of patella. The present study also demonstrated evidence that when predicting BMDs at their respective sites using ultrasound, the calcaneus appeared to be superior to the patella.

  20. Influence of ultrasound determination of fetal head position on mode of delivery: a pragmatic randomized trial.

    PubMed

    Popowski, T; Porcher, R; Fort, J; Javoise, S; Rozenberg, P

    2015-11-01

    To evaluate the influence of ultrasound determination of fetal head position on mode of delivery. This was a pragmatic open-label randomized controlled trial that included women with a singleton pregnancy in the vertex presentation at ≥ 37 weeks' gestation, cervical dilation ≥ 8 cm and who received epidural anesthesia. Women were assigned randomly to undergo either digital vaginal examination (VE group) or both digital vaginal and ultrasound examinations (VE+US group) to determine fetal head position. When the ultrasound and digital vaginal findings were inconsistent in the VE+US group, the ultrasound result was used for clinical management. The primary outcome assessed was operative delivery (Cesarean or instrumental vaginal delivery), and maternal and fetal morbidity were also assessed. The VE and VE+US groups included 959 and 944 women, respectively. The overall rate of operative delivery was significantly higher in the VE+US group than in the VE group: 33.7% vs 27.1%, respectively (relative risk (RR), 1.24 (95% CI, 1.08-1.43)), as was the rate of Cesarean delivery: 7.8% vs 4.9%, respectively (RR, 1.60 (95% CI, 1.12-2.28)). The rate of instrumental vaginal delivery was also higher, albeit not significantly: 25.8% in the VE+US group vs 22.2% in the VE group (RR, 1.16 (95% CI, 0.99-1.37)). Neonatal outcomes did not differ between the two groups. When analysis was restricted to instrumental vaginal deliveries only, maternal and neonatal morbidity outcomes were similar in both groups. Correction of fetal occiput position, determined initially by digital vaginal examination, using systematic ultrasound examination did not improve management of labor and increased the rate of operative delivery without decreasing maternal and neonatal morbidity. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  1. [Feasibility of sonography in the diagnosis of congenital heart diseases in dogs].

    PubMed

    Schneider, M; Schneider, I; Neu, H

    1998-05-01

    In ultrasound examination of the heart it is useful to combine the following techniques: echocardiography (in 2D and M-mode) gives information about morphology and motion of the heart. By using Doppler echocardiography (black and white or preferably colour) it is possible to evaluate bloodstreams and with contrast echocardiography shunts in the heart can be demonstrated. In our study (1994-1996) the following congenital heart defects were the most common in dogs: subaortic stenosis (SAS, 41%), pulmonic stenosis (PS, 19%), patent ductus arteriosus (PDA, 11%) and the combination of subaortic stenosis with pulmonic stenosis (11%). Echocardiography allows the morphologic evaluation of the primary defect in detail, for example the differentiation between aortic valve stenosis and subaortic stenosis. However the exact identification of the patent ductus arterious and of the morphology in pulmonic stenosis can remain difficult, especially in patients showing dyspnoe. In heart sonography quantitative measurements are available to graduate the defects, but guidelines for these measurements are not yet defined. The demonstration of secondary and combined defects, which are important for therapy is easily possible with heart ultrasound examination. Secondary insufficiencies are often seen at the mitral valve because of primary subaortic stenosis or patent ductus arteriosus and at the tricuspid valve because of pulmonic stenosis. For differentiation of combined heart defects (SAS with PS; SAS with PDA; PS with atrium septum defect) heart ultrasound is extremely valuable.

  2. Thyroid aplasia in male sibling of heterozygotic twins born to the hyperthyroid mother treated with propylthiouracil during pregnancy (case report).

    PubMed

    Almarzouki, A A

    2012-01-01

    A 30-year-old pregnant female was diagnosed to have thyrotoxicosis (TSH= 0.005 µU/ml) at 13th week of gestation. Propylthiouracil (PTU; 200 mg daily) was prescribed to her and four weekly follow ups by the endocrinologist and obstetrician were ensured. At each examination TSH, FT4 and FT3 levels were normal and she became symptom free. Repeated ultrasound examination throughout the pregnancy did not reveal any fetal abnormality. The lady normally delivered heterozygotic twins. Umbilical cord blood of the baby boy twin showed a high TSH (541 µU/ml; reference range 0.270 - 4.20 μU/ml). He was started on thyroxine therapy (50 µg once daily). Ultrasound reported the absence of the thyroid gland. One month later TSH was within normal range and thyroxine dose was adjusted to 25 µg once daily. Repeated ultrasound confirmed the absence of thyroid gland. TSH was repeatedly normal. The boy is currently doing well on thyroxine replacement therapy. The other non-identical twin was a healthy girl with normal thyroid function tests and always thereafter. This case report suggested that PTU could be a hazardous drug to the fetus, since the mother gave birth to a baby with thyroid aplasia. PTU, Thyroid aplasia, Thyrotoxicosis, TSH.

  3. Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.

    PubMed

    Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A

    2010-02-01

    Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.

  4. Cell-penetrating peptide-doxorubicin conjugate loaded NGR-modified nanobubbles for ultrasound triggered drug delivery.

    PubMed

    Lin, Wen; Xie, Xiangyang; Deng, Jianping; Liu, Hui; Chen, Ying; Fu, Xudong; Liu, Hong; Yang, Yang

    2016-01-01

    A new drug-targeting system for CD13(+) tumors has been developed, based on ultrasound-sensitive nanobubbles (NBs) and cell-permeable peptides (CPPs). Here, the CPP-doxorubicin conjugate (CPP-DOX) was entrapped in the asparagine-glycine-arginine (NGR) peptide modified NB (CPP-DOX/NGR-NB) and the penetration of CPP-DOX was temporally masked; local ultrasound stimulation could trigger the CPP-DOX release from NB and activate its penetration. The CPP-DOX/NGR-NBs had particle sizes of about 200 nm and drug entrapment efficiency larger than 90%. In vitro release results showed that over 85% of the encapsulated DOX or CPP-DOX would release from NBs in the presence of ultrasound, while less than 1.5% of that (30 min) without ultrasound. Cell experiments showed the higher cellular CPP-DOX uptake of CPP-DOX/NGR-NB among the various NB formulations in Human fibrosarcoma cells (HT-1080, CD13(+)). The CPP-DOX/NGR-NB with ultrasound treatment exhibited an increased cytotoxic activity than the one without ultrasound. In nude mice xenograft of HT-1080 cells, CPP-DOX/NGR-NB with ultrasound showed a higher tumor inhibition effect (3.1% of T/C%, day 24), longer median survival time (50 days) and excellent body safety compared with the normal DOX injection group. These results indicate that the constructed vesicle would be a promising drug delivery system for specific cancer treatment.

  5. Performance of Ultrasound in the Diagnosis of Gout in a Multi-Center Study: Comparison with Monosodium Urate Crystal Analysis as the Gold Standard

    PubMed Central

    Ogdie, Alexis; Taylor, William J; Neogi, Tuhina; Fransen, Jaap; Jansen, Tim L; Schumacher, H. Ralph; Louthrenoo, Worawit; Vazquez-Mellado, Janitzia; Eliseev, Maxim; McCarthy, Geraldine; Stamp, Lisa K.; Perez-Ruiz, Fernando; Sivera, Francisca; Ea, Hang-Korng; Gerritsen, Martijn; Cagnotto, Giovanni; Cavagna, Lorenzo; Lin, Chingtsai; Chou, Yin-Yi; Tausche, Anne-Kathrin; Ochtrop, Manuella Lima Gomes; Janssen, Matthijs; Chen, Jiunn-Horng; Slot, Ole; Lazovskis, Juris; White, Douglas; Cimmino, Marco A.; Uhlig, Till; Dalbeth, Nicola

    2017-01-01

    Objectives To examine the performance of ultrasound for the diagnosis of gout using presence of monosodium urate (MSU) crystals as the gold standard. Methods We analyzed data from the Study for Updated Gout Classification Criteria (SUGAR), a large, multi-center observational cross-sectional study of consecutive subjects with at least one swollen joint who conceivably may have gout. All subjects underwent arthrocentesis; cases were subjects with MSU crystal confirmation. Rheumatologists or radiologists, blinded to the results of the MSU crystal analysis, performed ultrasound on one or more clinically affected joints. Ultrasound findings of interest were: double contour sign (DCS), tophus, and ‘snowstorm’ appearance. Sensitivity, specificity, positive and negative predictive values (PPV and NPV) were calculated. Multivariable logistic regression models were used to examine factors associated with positive ultrasound results among subjects with gout. Results Ultrasound was performed in 824 subjects (416 cases and 408 controls). The sensitivity, specificity, PPV and NPV for the presence of any one of the features were 76.9%, 84.3%, 83.3% and 78.1% respectively. Sensitivity was higher among subjects with disease ≥2 years duration and among subjects with subcutaneous nodules on exam (suspected tophus). Associations with a positive ultrasound finding included suspected clinical tophus (odds ratio 4.77; 95% CI 2.23–10.21), any abnormal plain film radiograph (4.68; 2.68–8.17) and serum urate (1.31; 1.06–1.62). Conclusions Ultrasound features of MSU crystal deposition had high specificity and high positive predictive value but more limited sensitivity for early gout. The specificity remained high in subjects with early disease and without clinical signs of tophi. PMID:27748084

  6. Estimation of gonad volume, fecundity, and reproductive stage of shovelnose sturgeon using sonography and endoscopy with application to the endangered pallid sturgeon

    USGS Publications Warehouse

    Bryan, J.L.; Wildhaber, M.L.; Papoulias, D.M.; DeLonay, A.J.; Tillitt, D.E.; Annis, M.L.

    2007-01-01

    Most species of sturgeon are declining in the Mississippi River Basin of North America including pallid (Scaphirhynchus albus F. and R.) and shovelnose sturgeons (S. platorynchus R.). Understanding the reproductive cycle of sturgeon in the Mississippi River Basin is important in evaluating the status and viability of sturgeon populations. We used non-invasive, non-lethal methods for examining internal reproductive organs of shovelnose and pallid sturgeon. We used an ultrasound to measure egg diameter, fecundity, and gonad volume; endoscope was used to visually examine the gonad. We found the ultrasound to accurately measure the gonad volume, but it underestimated egg diameter by 52%. After correcting for the measurement error, the ultrasound accurately measured the gonad volume but it was higher than the true gonad volume for stages I and II. The ultrasound underestimated the fecundity of shovelnose sturgeon by 5%. The ultrasound fecundity was lower than the true fecundity for stage III and during August. Using the endoscope, we viewed seven different egg color categories. Using a model selection procedure, the presence of four egg categories correctly predicted the reproductive stage ± one reproductive stage of shovelnose sturgeon 95% of the time. For pallid sturgeon, the ultrasound overestimated the density of eggs by 49% and the endoscope was able to view eggs in 50% of the pallid sturgeon. Individually, the ultrasound and endoscope can be used to assess certain reproductive characteristics in sturgeon. The use of both methods at the same time can be complementary depending on the parameter measured. These methods can be used to track gonad characteristics, including measuring Gonadosomatic Index in individuals and/or populations through time, which can be very useful when associating gonad characteristics with environmental spawning triggers or with repeated examinations of individual fish throughout the reproductive cycle.

  7. Impact of mediolateral episiotomy on incidence of obstetrical anal sphincter injury diagnosed by endoanal ultrasound.

    PubMed

    Drusany Staric, Kristina; Lukanovic, Adolf; Petrocnik, Petra; Zacesta, Vita; Cescon, Corrado; Lucovnik, Miha

    2017-08-01

    to examine potential association between mediolateral episiotomy and reduced incidence of obstetrical anal sphincter injuries (OASIS) diagnosed by endoanal ultrasound. prospective cohort study. tertiary referral university hospital. sixty nulliparous women at 28-33 weeks of gestation with singleton pregnancies were included between 2010 and 2012. participants were examined with endoanal ultrasound at 28-33 weeks gestation and at 6-7 weeks post-partum. At both visits, symptoms of anal incontinence were assessed using Cleveland Clinic (Wexner) faecal incontinence scoring system. Mann Whitney U-test and χ 2 test was used to compare groups with vs. without episiotomy and groups with vs. without OASIS diagnosed by ultrasound. χ 2 test was used to assess correlation between OASIS and anal incontinence symptoms (p≤0.05 considered significant). None of the women included had sphincter injury or anal incontinence before childbirth. All delivered vaginally. Mediolateral episiotomy was performed in 33 (55%) cases. Six (10%) had OASIS on endoanal ultrasound (two were also diagnosed clinically), and 11 had symptoms of anal incontinence post-partum. No significant differences were seen in clinical characteristics between groups with vs. without episiotomy. No significant differences were seen in episiotomy rate (p=0.14), angle (p=0.42) and length (p=0.14) between groups with vs. without OASIS on ultrasound. Correlation between anal incontinence symptoms and sonographically diagnosed OASIS was statistically significant (p=0.04). mediolateral episiotomy does not seem to be protective against clinically or sonographically diagnosed OASIS even when episiotomy technique is considered. Endoanal ultrasound allows a significantly better detection of symptomatic OASIS compared to clinical examination alone. mediolateral episiotomy should be considered only when shortening the second stage of labour is indicated due to foetal distress, and not as a means of OASIS prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Release of indomethacin from ultrasound dry granules containing lactose-based excipients.

    PubMed

    Cavallari, Cristina; Albertini, Beatrice; Rodriguez, Lorenzo; Rabasco, Antonio M; Fini, Adamo

    2005-01-20

    Physical mixtures were prepared containing indomethacin and beta-lactose and alpha-lactose-based excipients (Ludipress and Cellactose). The mixtures were compacted with the aid of ultrasound, obtaining tablets, which were milled and sieved. Granules thus obtained were examined by optical microscopy and differential scanning calorimetry. The intense yellow color of the granules and the absence of indomethacin peak in thermograms suggest important modifications of indomethacin physical state; the drug thus modified appears to be spread on the excipient particle surface as a thin film, giving a lustrous appearance. No influence of ultrasound was observed on phase transition concerning lactose; only loss of water was important under high energy ultrasound. Dissolution profiles suggest an increased release of the drug from the systems treated with ultrasound at high energy, with respect to a traditional compaction; while no difference could be evidenced among the three excipients that, however, appear all suitable for this ultrasound-aided direct compression process.

  9. Experimental analysis of behavior in nanobubbles using echograms under ultrasound exposure

    NASA Astrophysics Data System (ADS)

    Wada, Hikaru; Koido, Jun; Miyazawa, Shinya; Mochizuki, Takashi; Masuda, Kohji; Unga, Johan; Oda, Yusuke; Suzuki, Ryo; Maruyama, Kazuo

    2016-07-01

    Although we have reported our attempts to actively control microbubbles in flow using acoustic radiation force for future drug delivery systems, the microbubbles we used are not applicable for in vivo experiments. Thus, we examined two types of nanobubble with a drug-retaining function. Because the nanobubbles are invisible in a conventional optical observation, we observed the behavior of nanobubbles using ultrasound images (echograms). First, we found the optimal settings of echography to guarantee the relationship between the brightness variation and lipid concentration of nanobubbles. Then, we derived the destructive coefficient using two types of path under continuous ultrasound exposure of 5 MHz. Results indicate that the controllability is related to the construction of nanobubbles and the spatial distribution of the ultrasound field. We realized that the design of the ultrasound field is important with Bubble A, whereas the frequency of ultrasound emission needs to be discussed with Bubble B.

  10. Ultrasound in athletes: emerging techniques in point-of-care practice.

    PubMed

    Yim, Eugene S; Corrado, Gianmichel

    2012-01-01

    Ultrasound offers sports medicine clinicians the potential to diagnose, treat, and manage a broad spectrum of conditions afflicting athletes. This review article highlights applications of ultrasound that hold promise as point-of-care diagnostics and therapeutic tools that can be used directly by clinicians to direct real-time management of athletes. Point-of-care ultrasound has been examined most in the context of musculoskeletal disorders in athletes, with attention given to Achilles tendinopathy, patellar tendinopathy, hip and thigh pathology, elbow tendinopathy, wrist pathology, and shoulder pain. More research has focused on therapeutic applications than diagnostic, but initial evidence has been generated in both. Preliminary evidence has been published also on abdominal ultrasound for splenic enlargement in mononucleosis, cardiopulmonary processes and hydration status, deep vein thrombosis, and bone mineral density. Further research will be required to validate these applications and to explore further applications of portable ultrasound that can be used in the care of athletes.

  11. Motion Detection in Ultrasound Image-Sequences Using Tensor Voting

    NASA Astrophysics Data System (ADS)

    Inba, Masafumi; Yanagida, Hirotaka; Tamura, Yasutaka

    2008-05-01

    Motion detection in ultrasound image sequences using tensor voting is described. We have been developing an ultrasound imaging system adopting a combination of coded excitation and synthetic aperture focusing techniques. In our method, frame rate of the system at distance of 150 mm reaches 5000 frame/s. Sparse array and short duration coded ultrasound signals are used for high-speed data acquisition. However, many artifacts appear in the reconstructed image sequences because of the incompleteness of the transmitted code. To reduce the artifacts, we have examined the application of tensor voting to the imaging method which adopts both coded excitation and synthetic aperture techniques. In this study, the basis of applying tensor voting and the motion detection method to ultrasound images is derived. It was confirmed that velocity detection and feature enhancement are possible using tensor voting in the time and space of simulated ultrasound three-dimensional image sequences.

  12. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  13. Ultrasound-guided pleural access.

    PubMed

    Shojaee, Samira; Argento, A Christine

    2014-12-01

    Ultrasonography of the thorax has become a more recognized tool in pulmonary medicine, thanks to continuing clinical research that has proven its many valuable roles in the day-to-day management of pulmonary and pleural diseases. Ultrasound examination is a cost-effective imaging modality that permits the pulmonologist to obtain information about the pathologies in the thorax without the risk of exposure to ionizing radiation, providing the examiner with real-time and immediate results. Its ease of use and training along with its portability to the patient's bedside and accurate examination of the pleural space has allowed for safer pleural procedures such as thoracentesis, chest tube placement, tunneled pleural catheter placement, and medical thoracoscopy. In this review, we summarize the technique of chest ultrasonography, compare ultrasound to other frequently used thoracic imaging modalities, and focus on its use in obtaining pleural access while performing invasive pleural procedures. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Clinical responses to focused ultrasound applied to women with vulval intraepithelial neoplasia.

    PubMed

    Jia, Ying; Wu, Jin; Xu, Man; Tang, Liangdan; Li, Chengzhi; Luo, Ming; Lou, Meng

    2014-11-01

    Focused ultrasound waves penetrate superficial tissues and are aimed toward the target tissues at specific depths to exert their biological effects. Focused ultrasound has been applied for a number of clinical indications, including vulval dystrophies and low-grade vulval disease. This study aimed to assess the efficacy and safety of focused ultrasound treatment of high-grade vulval intraepithelial neoplasia (VIN). Eighteen women with high-grade VIN were recruited and treated with focused ultrasound. During each posttreatment follow-up, the safety of, side effects of, and clinical responses to focused ultrasound were evaluated by a standardized protocol, including symptoms, clinical appearance, and histologic findings. All patients completed the designed follow-ups. In most cases, superficial mild to moderate swelling and blisters were seen in the focused ultrasound-treated skin but not in adjacent normal skin. Of the 18 patients, 16 showed complete histologic regression and resolution of symptoms 6 months after treatment. Of the other 2 patients, 1 showed complete regression after a second focused ultrasound treatment. The other patient did not respond to the focused ultrasound treatment and underwent a partial vulvectomy 6 months after treatment. None of the patients developed invasive carcinoma of the vulva during the follow-up period. One patient had local pruritus that was not alleviated by anti-inflammatory medication and local care. The complete responses observed in women with high-grade VIN treated by focused ultrasound, together with the preservation of adjacent normal tissue, suggest that focused ultrasound may be considered for treatment of high-grade VIN. © 2014 by the American Institute of Ultrasound in Medicine.

  15. Computer-Aided Diagnosis of Different Rotator Cuff Lesions Using Shoulder Musculoskeletal Ultrasound.

    PubMed

    Chang, Ruey-Feng; Lee, Chung-Chien; Lo, Chung-Ming

    2016-09-01

    The lifetime prevalence of shoulder pain approaches 70%, which is mostly attributable to rotator cuff lesions such as inflammation, calcific tendinitis and tears. On clinical examination, shoulder ultrasound is recommended for the detection of lesions. However, there exists inter-operator variability in diagnostic accuracy because of differences in the experience and expertise of operators. In this study, a computer-aided diagnosis (CAD) system was developed to assist ultrasound operators in diagnosing rotator cuff lesions and to improve the practicality of ultrasound examination. The collected cases included 43 cases of inflammation, 30 cases of calcific tendinitis and 26 tears. For each case, the lesion area and texture features were extracted from the entire lesions and combined in a multinomial logistic regression classifier for lesion classification. The proposed CAD achieved an accuracy of 87.9%. The individual accuracy of this CAD system was 88.4% for inflammation, 83.3% for calcific tendinitis and 92.3% for tears. Cohen's k was 0.798. On the basis of its diagnostic performance, clinical use of this CAD technique has promise. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Low intensity ultrasound induces apoptosis via MPT channel on mitochondrial membrane: Target for regulating cancer therapy or not?

    NASA Astrophysics Data System (ADS)

    Feng, Yi; Wan, Mingxi

    2017-03-01

    To discuss how the mitochondrion is involved in low intensity ultrasound induced apoptosis, HepG2 cells were irradiated by low intensity focused ultrasound (ISPTA = 3W/cm2, 1 min) and then cultured from 3-12 h post irradiation in the study. The morphological alteration was examined by light and fluorescent microscopy respectively. Cell viability and apoptosis were examined by trypan blue staining and flow cytometry with double staining of FITC-labelled Annexin-V/PI. Key proteins responded to irradiation were screened out by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and shotgun proteomic methods with Agilent 1100 HPLC-Chip-MS technology. Representative apoptotic morphological characteristics and increased percentage of apoptotic cells were achieved. Six important proteins (4 up-regulated and 2 down-regulated) were selected and analyzed. It revealed low intensity focused ultrasound could induce apoptosis in HepG2 cells and the US-induced apoptosis was mitochondria-dependent and caspases-dependent. Moreover, mitochondrial membrane permeability transition (MPT) is related to ultrasound induced apoptosis, but VDAC may be not the main MPT channel. Understanding it could help to assist the cancer therapy by regulating the MPT as the target.

  17. Application of airborne ultrasound in the convective drying of fruits and vegetables: A review.

    PubMed

    Fan, Kai; Zhang, Min; Mujumdar, Arun S

    2017-11-01

    The application of airborne ultrasound is a promising technology in the drying of foods, particularly to fruits and vegetables. In this paper, designs of dryers using ultrasound to combine the convective drying process are described. The main factors affecting the drying kinetics with the ultrasound application are discussed. The results show that the ultrasound application accelerated the drying kinetics. Ultrasound application during the convective drying of fruits and vegetables shorten the drying time. Ultrasound application can produce an increase of the effective moisture diffusivity and the mass transfer coefficient. The influence of ultrasound on physical and chemical parameters evaluating the product quality is reviewed. Ultrasound application can decrease the total color change, reveal a low water activity and reduce the loss of some nutrient elements. Meanwhile, ultrasound application can also better preserve the microstructure of fruits and vegetables in comparison to convective drying. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Ultrasound enhances retrovirus-mediated gene transfer.

    PubMed

    Naka, Toshio; Sakoda, Tsuyoshi; Doi, Takashi; Tsujino, Takeshi; Masuyama, Tohru; Kawashima, Seinosuke; Iwasaki, Tadaaki; Ohyanagi, Mitsumasa

    2007-01-01

    Viral vector systems are efficient for transfection of foreign genes into many tissues. Especially, retrovirus based vectors integrate the transgene into the genome of the target cells, which can sustain long term expression. However, it has been demonstrated that the transduction efficiency using retrovirus is relatively lower than those of other viruses. Ultrasound was recently reported to increase gene expression using plasmid DNA, with or without, a delivery vehicle. However, there are no reports, which show an ultrasound effect to retrovirus-mediated gene transfer efficiency. Retrovirus-mediated gene transfer systems were used for transfection of 293T cells, bovine aortic endothelial cells (BAECs), rat aortic smooth muscle cells (RASMCs), and rat skeletal muscle myoblasts (L6 cells) with beta-galactosidase (beta-Gal) genes. Transduction efficiency and cell viability assay were performed on 293T cells that were exposed to varying durations (5 to 30 seconds) and power levels (1.0 watts/cm(2) to 4.0 watts/cm(2)) of ultrasound after being transduced by a retrovirus. Effects of ultrasound to the retrovirus itself was evaluated by transduction efficiency of 293T cells. After exposure to varying power levels of ultrasound to a retrovirus for 5 seconds, 293T cells were transduced by a retrovirus, and transduction efficiency was evaluated. Below 1.0 watts/cm(2) and 5 seconds exposure, ultrasound showed increased transduction efficiency and no cytotoxicity to 293T cells transduced by a retrovirus. Also, ultrasound showed no toxicity to the virus itself at the same condition. Exposure of 5 seconds at the power of 1.0 watts/cm(2) of an ultrasound resulted in significant increases in retrovirus-mediated gene expression in all four cell types tested in this experiment. Transduction efficiencies by ultrasound were enhanced 6.6-fold, 4.8-fold, 2.3-fold, and 3.2-fold in 293T cells, BAECs, RASMCs, and L6 cells, respectively. Furthermore, beta-Gal activities were also increased by the retrovirus with ultrasound exposure in these cells. Adjunctive ultrasound exposure was associated with enhanced retrovirus-mediated transgene expression in vitro. Ultrasound associated local gene therapy has potential for not only plasmid-DNA-, but also retrovirus-mediated gene transfer.

  19. Effect of ultrasound sonication on electroplating of iridium.

    PubMed

    Ohsaka, Takashi; Isaka, Motohiro; Hirano, Katsuhiko; Ohishi, Tomoji

    2008-04-01

    Effect of ultrasound sonication was examined on the electroplating of iridium in aqueous hexabromoiridate(III) solution. The electrodeposits were evaluated by observing the defects of the iridium deposits by means of voltammetry, in which the current-potential curves of the iridium deposits on copper were measured. Applying ultrasound sonication to the electroplating of iridium decreased the defects including the cracks in the deposit whenever the glycerol as the additives was contained or not in the electrolyte.

  20. Comparison of central corneal thickness measurement using ultrasonic pachymetry, rotating Scheimpflug camera, and scanning-slit topography.

    PubMed

    Sedaghat, Mohammad Reza; Daneshvar, Ramin; Kargozar, Abbas; Derakhshan, Akbar; Daraei, Mona

    2010-12-01

    To evaluate and compare central corneal thickness measurements using rotating Scheimpflug camera, scanning-slit topography, and ultrasound pachymetry in virgin, healthy corneas. Prospective, observational, cross-sectional study. Central corneal thickness in 157 healthy eyes of 157 patients without ocular abnormalities other than refractive errors was measured, in a sequential order, once with rotating Scheimpflug camera and scanning-slit topography and 3 times with ultrasound pachymetry as the last part of examination. All measurements were performed by a single experienced examiner. The results from scanning-slit topography are given with and without correction for "acoustic correction factor" of 0.92. The average measurements of central corneal thickness by rotating Scheimpflug imaging, scanning-slit pachymetry, and ultrasound were 537.15 ± 32.98 μm, 542.06 ± 39.04 μm, and 544.07 ± 34.75 μm, respectively. The mean differences between modalities were 6.92 μm between rotating Scheimpflug and ultrasound (P < .0001), 2.01 μm between corrected scanning-slit and ultrasound (P = .204), and 4.91 μm between corrected scanning-slit and rotating Scheimpflug imaging (P = .001). According to Bland-Altman analysis, highest agreement was between ultrasonic and rotating Scheimpflug pachymetry. In the assessment of normal corneas, rotating Scheimpflug topography measures central corneal thickness values with higher agreement to ultrasound pachymetry. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. [Ultrasound biomicroscopy of conjunctival lesions].

    PubMed

    Buchwald, Hans-Jürgen; Müller, Andreas; Spraul, Christoph W; Lang, Gerhard K

    2003-01-01

    The value of ultrasound biomicroscopy in the diagnosis of conjunctival lesions is not well established. For the examination of conjunctival lesions, we used an ultrasound biomicroscope (Humphrey, Zeiss, Oberkochen) with a high frequency transducer (30 MHz). Between January 2000 and August 2001, 28 patients (16 female, 12-male) with conjunctival lesions, aged 9 to 81 years, were available for this study. Histological examination of the excised tissue displayed the presence of a compound naevus (8/28), cysts (6/28), inflammatory processes (3/28), granulomatous processes (2/28), lymphomas (2/28), foreign bodies (2/28), a pterygium (2/28), a malignant melanoma (1/28), a primary acquired melanosis (1/28), and a conjunctival amyloidosis (1/28). Using ultrasound biomicroscopy we were able to demonstrate a cystic tumour in the six patients (21 %) with a cyst of the conjunctiva. In patients suffering from solid tumours of the conjunctiva the definite diagnosis could not be made with ultrasound biomicroscopy alone. The eight patients with compound naevus displayed a somewhat heterogeneous sonographic structure within the tumour. In the patient with a foreign body we were able to demonstrate posterior shadowing of the underlying tissue. For evaluation of conjunctival lesions caused by a cyst or a solid tumour, ultrasound biomicroscopy may be an additional diagnostic tool, e. g. for assessing the margins of the tumour. However, up to now it is not possible to differentiate between different lesions solely by means of ultrasonography.

  2. [The role of ultrasonography exam in orbital-ocular tumors].

    PubMed

    Ciocâlteu, Alina Mihaela; Ardeleanu, S; Checheriţă, I A

    2011-01-01

    Ophthalmology is one of the specialties that have particularly benefited from the contribution of ultrasonography exam as a method of investigation. Ultrasonography is very much essential for diagnostic to complement other clinical and laboratory investigations, providing images in real time. The basic principle of diagnostic ultrasound is to study and to interpret the changes they undergo when crossing ultrasonic waves diverse biological properties different sound, and such injuries can be traced in the dynamics or can be documented on photographic paper and thus can diagnose correct certain eye diseases. The indications for performing ultrasound consist in: measurement of distances and volumes, examine difficult or inaccessible case of opaque media; ophthalmoscopic view of a mass lesion, examine the orbit or optic nerve. The advantages of ultrasound for orbital-ocular tumors are represented by the fact that ultrasound is a noninvasive method, safe, well tolerated, less expensive that the advantage of determining the position and distance from structures ocular tumor. High frequency ultrasound provides excellent resolution of 0-1 to 0.01 mm, and serial scans allow tracking progress and measuring lesion diameters tumor while allowing monitoring and evaluation of stereotactic radiation treatments applied to small tumors. In conclusion ultrasound allows not only early diagnosis of eye tumors, but accurate assessment of the proposed therapy and of the evolution of detected mass lesions or tumors.

  3. PRospective Imaging of CErvical cancer and neoadjuvant treatment (PRICE) study: role of ultrasound to predict partial response in locally advanced cervical cancer patients undergoing chemoradiation and radical surgery.

    PubMed

    Testa, A C; Ferrandina, G; Moro, F; Pasciuto, T; Moruzzi, M C; De Blasis, I; Mascilini, F; Foti, E; Autorino, R; Collarino, A; Gui, B; Zannoni, G F; Gambacorta, M A; Valentini, A L; Rufini, V; Scambia, G

    2018-05-01

    Chemoradiation-based neoadjuvant treatment followed by radical surgery is an alternative therapeutic strategy for locally advanced cervical cancer (LACC), but ultrasound variables used to predict partial response to neoadjuvant treatment are not well defined. Our goal was to analyze prospectively the potential role of transvaginal ultrasound in early prediction of partial pathological response, assessed in terms of residual disease at histology, in a large, single-institution series of LACC patients triaged to neoadjuvant treatment followed by radical surgery. Between October 2010 and June 2014, we screened 108 women with histologically documented LACC Stage IB2-IVA, of whom 88 were included in the final analysis. Tumor volume, three-dimensional (3D) power Doppler indices and contrast parameters were obtained before (baseline examination) and after 2 weeks of treatment. The pathological response was defined as complete (absence of any residual tumor after treatment) or partial (microscopic and/or macroscopic residual tumor at pathological examination). Complete-response and partial-response groups were compared and receiver-operating characteristics (ROC) curves were generated for ultrasound variables that were statistically significant on univariate analysis to evaluate their diagnostic ability to predict partial pathological response. There was a complete pathological response to neoadjuvant therapy in 40 (45.5%) patients and a partial response in 48 (54.5%). At baseline examination, tumor volume did not differ between the two groups. However, after 2 weeks of neoadjuvant treatment, the tumor volume was significantly greater in patients with partial response than it was in those with complete response (P = 0.019). Among the 3D vascular indices, the vascularization index (VI) was significantly lower in the partial-response compared with the complete-response group, both before and after 2 weeks of treatment (P = 0.037 and P = 0.024, respectively). At baseline examination in the contrast analysis, women with partial response had lower tumor peak enhancement (PE) as well as lower tumor wash-in rate (WiR) and longer tumor rise time (RT) compared with complete responders (P = 0.006, P = 0.003, P = 0.038, respectively). There was no difference in terms of contrast parameters after 2 weeks of treatment. ROC-curve analysis of baseline parameters showed that the best cut-offs for predicting partial pathological response were 41.5% for VI (sensitivity, 63.6%; specificity, 66.7%); 16123.5 auxiliary units for tumor PE (sensitivity, 47.9%; specificity, 84.2%); 7.8 s for tumor RT (sensitivity, 68.8%; specificity, 57.9%); and 4902 for tumor WiR (sensitivity, 77.1%; specificity, 60.5%). ROC curves of parameters after 2 weeks of treatment showed that the best cut-off for predicting partial pathological response was 18.1 cm 3 for tumor volume (sensitivity, 70.8%; specificity 60.0%) and 39.5% for VI (sensitivity; 62.5%; specificity, 73.5%). Ultrasound and contrast parameters differ between LACC patients with complete response and those with partial response before and after 2 weeks of neoadjuvant treatment. However, neither ultrasound parameters before treatment nor those after 2 weeks of treatment had cut-off values with acceptable sensitivity and specificity for predicting partial pathological response to neoadjuvant therapy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

  4. Bacterial contamination of ultrasound probes in different radiological institutions before and after specific hygiene training: do we have a general hygienical problem?

    PubMed

    Sartoretti, Thomas; Sartoretti, Elisabeth; Bucher, Candid; Doert, Aleksis; Binkert, Christoph; Hergan, Klaus; Meissnitzer, Matthias; Froehlich, Johannes; Kolokythas, Orpheus; Matoori, Simon; Orasch, Christina; Kos, Sebastian; Sartoretti-Schefer, Sabine; Gutzeit, Andreas

    2017-10-01

    Aim was to investigate hygienic conditions of ultrasound probes before and after hygiene training in radiology institutions in comparison to bacterial contamination in public places. In three radiology departments, bacterial contamination was evaluated using baseline agar plates for cultures taken from 36 ultrasound probes. Afterwards teams were trained by a hygiene service centre and 36 ultrasound probes were routinely disinfected with regular disinfecting wipes and then evaluated. In comparison, bacterial contamination in public places (bus poles, n = 11; toilet seats, n = 10) were analysed. Plates were routinely incubated and the number of colony forming units (CFU) analysed. Cultures taken from the probes showed a median of 53 CFU before and 0 CFU after training (p < 0.001). Cultures taken from public places showed a median of 4 CFU from toilets and 28 from bus poles and had lower bacterial load in comparison to ultrasound probes before training (p = 0.055, toilets; p = 0.772, bus poles), without statistical significance. Bacterial contamination of ultrasound probes prior to hygiene training proved to be high and showed higher bacterial load than toilets seats or bus poles. Radiologists should be aware that the lack of hygiene in the field of ultrasound diagnostics puts patients at risk of healthcare-associated infections. • Hospital-associated infections are a problem for patient care. • Hygiene training of staff prevents bacterial contamination of ultrasound probes. • Disinfection of ultrasound probes is an easy method to protect patients.

  5. Gestational age assessment in malaria pregnancy cohorts: a prospective ultrasound demonstration project in Malawi

    PubMed Central

    2013-01-01

    Background Malaria during pregnancy is associated with an increased risk for low birth weight (<2500 grams). Distinguishing infants that are born premature (< 37 weeks) from those that are growth-restricted (less than the 10th percentile at birth) requires accurate assessment of gestational age. Where ultrasound is accessible, sonographic confirmation of gestational age is more accurate than menstrual dating. The goal was to pilot the feasibility and utility of adding ultrasound to an observational pregnancy malaria cohort. Methods In July 2009, research staff (three mid-level clinical providers, one nurse) from The Blantyre Malaria Project underwent an intensive one-week ultrasound training to perform foetal biometry. Following an additional four months of practice and remote image review, subjects from an ongoing cohort were recruited for ultrasound to determine gestational age. Gestational age at delivery established by ultrasound was compared with postnatal gestational age assessment (Ballard examination). Results One hundred and seventy-eight women were enrolled. The majority of images were of good quality (94.3%, 509/540) although a learning curve was apparent with 17.5% (24/135) images of unacceptable quality in the first 25% of scans. Ultrasound was used to date 13% of the pregnancies when menstrual dates were unknown and changed the estimated gestational age for an additional 25%. There was poor agreement between the gestational age at delivery as established by the ultrasound protocol compared to that determined by the Ballard examination (bias 0.8 weeks, limits of agreement -3.5 weeks to 5.1 weeks). The distribution of gestational ages by Ballard suggested a clustering of gestational age around the mean with 87% of the values falling between 39 and 41 weeks. The distribution of gestational age by ultrasound confirmed menstrual dates was more typical. Using ultrasound confirmed dates as the gold standard, 78.5% of preterm infants were misclassified as term and 26.8% of small-for gestational age infants misclassified as appropriately grown by Ballard. Conclusion Ultrasound should be strongly considered in prospective malaria studies with obstetric endpoints to confirm gestational age and avoid misclassification of infants as premature or growth-restricted. The use of ultrasound does require a significant investment of time to maintain quality image acquisition. PMID:23734718

  6. Prenatal diagnosis of 47,XXX.

    PubMed

    Khoury-Collado, Fady; Wehbeh, Ammar N; Fisher, Allan J; Bombard, Allan T; Weiner, Zeev

    2005-05-01

    We report 2 cases of 47,XXX that were diagnosed prenatally and were screened positive for trisomy 21 by biochemical and ultrasound markers. These cases underline the importance of discussing the sex chromosome abnormalities during the genetic counseling after an abnormal triple screen test or ultrasound examination.

  7. Prenatal diagnosis of dwarfism by ultrasound screening.

    PubMed Central

    Weldner, B M; Persson, P H; Ivarsson, S A

    1985-01-01

    In a general, ultrasound screening programme, 12 453 women were examined at 16 and 32 weeks of pregnancy. The screening detected all limb deformities in the population during the study period. The seeming prevalence of dwarfism in the population was 750 per million. PMID:3907507

  8. Subjective ultrasound assessment, the ADNEX model and ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer.

    PubMed

    Epstein, E; Van Calster, B; Timmerman, D; Nikman, S

    2016-01-01

    To compare subjective ultrasound assessment and the ADNEX model with ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer. This was a prospective study including 143 consecutive women with disseminated malignancy of unknown primary origin, with a pelvic tumor/carcinosis. Women underwent either transvaginal or transrectal ultrasound as well as transabdominal ultrasound examination followed by tru-cut biopsy. The ultrasound examiner assessed tumor morphology, spread in the pelvis and abdomen, and predicted tumor origin as primary ovarian or metastatic using both subjective assessment and the ADNEX model. Histology from tru-cut biopsy served as the gold standard for assessment of diagnostic accuracy. Biopsy adequacy and the complication rate were assessed. Tru-cut biopsy was performed transvaginally in 131/143 (92%) women. Two women needed inpatient care (one had abdominal wall hematoma, and one infection). Biopsy resulted in a conclusive diagnosis in 126/143 (88%) women, amongst whom cytoreductive surgery was performed in 30/126 confirming the diagnosis in all cases. Non-ovarian metastatic cancer was found in 37/126 (29%) women and primary ovarian cancer in 89/126 (71%) women. Subjective ultrasound evaluation had a sensitivity of 82% (73/89) and a specificity of 70% (26/37) in predicting primary ovarian cancer. The ADNEX model had an area under the receiver-operating characteristics curve of 0.891 (95% CI, 0.794-0.946) (in women with an ovarian lesion, n = 104). Tumor origin was associated with age, CA 125, previous neoplasia, presence of omental cake and tumor mobility. Subjective ultrasound assessment and the ADNEX model can both be used to predict whether a pelvic tumor is metastatic and of non-ovarian origin, indicating the need for tru-cut biopsy, which is associated with very few complications and will provide a conclusive diagnosis in nine out of 10 women. Copyright © 2015 ISUOG. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  9. An uncovered risk factor of sonothrombolysis: Substantial fluctuation of ultrasound transmittance through the human skull.

    PubMed

    Wang, Zuojun; Komatsu, Teppei; Mitsumura, Hidetaka; Nakata, Norio; Ogawa, Takeki; Iguchi, Yasuyuki; Yokoyama, Masayuki

    2017-05-01

    Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. Previously, we reported substantial and periodic fluctuation of ultrasound transmittance through a bone-phantom plate following changes to ultrasound frequency, the thickness of the bone-phantom plate, and the distance between a transducer and the bone-phantom plate. In the present study, we clarify the transmittance behavior of medium-frequency ultrasound (from 400kHz to 600kHz) through the human skull, and examine reduction of the transmittance fluctuation. For the study, we measured transmittance of sinusoidal ultrasound waves at 400kHz, 500kHz, and 600kHz at 13 temple spots on 3 human skulls by changing the distance between a transducer and the skull bone, and found substantial and periodic fluctuation in the transmittance behaviors for these sinusoidal voltage excitations. Degrees of the fluctuation varied depending on the measurement spots. A fluctuation ratio between the maximum transmittance and the minimum transmittance reached 3 in some spots. This large transmittance fluctuation is considered to be a risk factor for sonothrombolysis therapies. We examined a modulated ultrasound wave to reduce the fluctuation, and succeeded in obtaining considerable reduction. The average fluctuation ratios for 400-kHz, 500-kHz, and 600-kHz waves were 2.38, 2.38, and 2.07, respectively. We successfully reduced the ratio to 1.72 by using a periodic selection of random frequency (PSRF)-type of modulation wave. The thus obtained results indicate that attention to the fluctuation in ultrasound transmittance through the skull is necessary for safe and effective sonothrombolysis therapies, and that modulated ultrasound waves constitute a powerful method for reducing the risk of fluctuation. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Analisys of pectoralis major tendon in weightlifting athletes using ultrasonography and elastography.

    PubMed

    Pochini, Alberto de Castro; Ferretti, Mario; Kawakami, Eduardo Felipe Kin Ito; Fernandes, Artur da Rocha Corrêa; Yamada, Andre Fukunishi; Oliveira, Gabriela Clemente de; Cohen, Moisés; Andreoli, Carlos Vicente; Ejnisman, Benno

    2015-01-01

    To evaluate tendinopathy of the pectoralis major muscle in weightlifting athletes using ultrasound and elastography. This study included 20 patients, 10 with rupture of the pectoralis major muscle and 10 control patients. We evaluated pectoralis major muscle contralateral tendon with ultrasonographic and elastography examinations. The ultrasonographic examinations were performed using a high-resolution B mode ultrasound device. The elastography evaluation was classified into three patterns: (A), if stiff (more than 50% area with blue staining); (B), if intermediate (more than 50% green); and (C), if softened (more than 50% red). Patients' mean age was 33±5.3 years. The presence of tendinous injury measured by ultrasound had a significant different (p=0.0055), because 80% of cases had tendinous injury versus 10% in the Control Group. No significant differences were seen between groups related with change in elastography (p=0.1409). Long-term bodybuilders had ultrasound image with more tendinous injury than those in Control Group. There was no statistical significance regarding change in tendon elasticity compared with Control Group.

  11. The role of ultrasonography in the management of lung and pleural diseases.

    PubMed

    Rumende, C Martin

    2012-04-01

    Ultrasonographic examination in pulmonology provides a revolutionary advance because it is very helpful in the diagnosis and management of various pleural and peripheral pulmonary defects. Lung ultrasonography allows the clinicians to diagnose some pulmonary abnormalities more rapidly, including the diagnosis of pleural effusion. Ultrasound examination also provides great assistance for the clinicians to perform invasive techniques in the field of pulmonology, which may increase the success rate and reduce the likelihood of complications. In addition to pleural effusion, other lung disorders can be diagnosed by ultrasound such as peripheral lung tumors and other pleural abnormalities caused by pleural fibrosis and tumor metastasis as well as the primary pleural tumor (mesothelioma). Ultrasound-guided invasive procedures include aspiration of minimal effusion, Transthoracal Needle Aspiration, Transthoracal biopsies and chest tube insertion. Lung ultrasound also offers other advantages, i.e. free from radiation hazards, portable, non-invasive and relatively inexpensive. Ultrasonography in the thorax also has its limitations, especially in detecting mediastinal abnormalities.

  12. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    PubMed Central

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024

  13. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    PubMed

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  14. Detecting breast microcalcifications using super-resolution ultrasound imaging: a clinical study

    NASA Astrophysics Data System (ADS)

    Huang, Lianjie; Labyed, Yassin; Hanson, Kenneth; Sandoval, Daniel; Pohl, Jennifer; Williamson, Michael

    2013-03-01

    Imaging breast microcalcifications is crucial for early detection and diagnosis of breast cancer. It is challenging for current clinical ultrasound to image breast microcalcifications. However, new imaging techniques using data acquired with a synthetic-aperture ultrasound system have the potential to significantly improve ultrasound imaging. We recently developed a super-resolution ultrasound imaging method termed the phase-coherent multiple-signal classification (PC-MUSIC). This signal subspace method accounts for the phase response of transducer elements to improve image resolution. In this paper, we investigate the clinical feasibility of our super-resolution ultrasound imaging method for detecting breast microcalcifications. We use our custom-built, real-time synthetic-aperture ultrasound system to acquire breast ultrasound data for 40 patients whose mammograms show the presence of breast microcalcifications. We apply our super-resolution ultrasound imaging method to the patient data, and produce clear images of breast calcifications. Our super-resolution ultrasound PC-MUSIC imaging with synthetic-aperture ultrasound data can provide a new imaging modality for detecting breast microcalcifications in clinic without using ionizing radiation.

  15. Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology-A WFUMB COE Project.

    PubMed

    Vinayak, Sudhir; Sande, Joyce; Nisenbaum, Harvey; Nolsøe, Christian Pállson

    2017-10-01

    Point-of-care ultrasound (POCUS) has become a topical subject and can be applied in a variety of ways with differing outcomes. The cost of all diagnostic procedures including obstetric ultrasound examinations is a major factor in the developing world and POCUS is only useful if it can be equated to good outcomes at a lower cost than a routine obstetric examination. The aim of this study was to assess a number of processes including accuracy of images and reports generated by midwives, performance of a tablet-sized ultrasound scanner, training of midwives to complete ultrasounds, teleradiology solution transmissions of images via internet, review of images by a radiologist, communication between midwife and radiologist, use of this technique to identify high-risk patients and improvement of the education and teleradiology model components. The midwives had no previous experience in ultrasound. They were stationed in rural locations where POCUS was available for the first time. After scanning the patients, an interim report was generated by the midwives and sent electronically together with all images to the main hospital for validation. Unique software was used to send lossless images by mobile phone using a modem. Transmission times were short and quality of images transmitted was excellent. All reports were validated by two experienced radiologists in our department and returned to the centers using the same transmission software. The transmission times, quality of scans, quality of reports and other parameters were recorded and monitored. Analysis showed excellent correlation between provisional and validated reports. Reporting accuracy of scans performed by the midwives was 99.63%. Overall flow turnaround time (from patient presentation to validated report) was initially 35 min but reduced to 25 min. The unique mobile phone transmission was faultless and there was no degradation of image quality. We found excellent correlation between final outcomes of the pregnancies and diagnoses on the basis of reports generated by the midwives. Only 1 discrepancy was found in the midwives' reports. Scan results versus actual outcomes revealed 2 discrepancies in the 20 patients identified as high risk. In conclusion, we found that it is valuable to train midwives in POCUS to use an ultrasound tablet device and transmit images and reports via the internet to radiologists for review of accuracy. This focus on the identification of high-risk patients can be valuable in a remote healthcare facility. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Arthroscopy or ultrasound in undergraduate anatomy education: a randomized cross-over controlled trial.

    PubMed

    Knobe, Matthias; Carow, John Bennet; Ruesseler, Miriam; Leu, Benjamin Moritz; Simon, Melanie; Beckers, Stefan K; Ghassemi, Alireza; Sönmez, Tolga T; Pape, Hans-Christoph

    2012-09-09

    The exponential growth of image-based diagnostic and minimally invasive interventions requires a detailed three-dimensional anatomical knowledge and increases the demand towards the undergraduate anatomical curriculum. This randomized controlled trial investigates whether musculoskeletal ultrasound (MSUS) or arthroscopic methods can increase the anatomical knowledge uptake. Second-year medical students were randomly allocated to three groups. In addition to the compulsory dissection course, the ultrasound group (MSUS) was taught by eight, didactically and professionally trained, experienced student-teachers and the arthroscopy group (ASK) was taught by eight experienced physicians. The control group (CON) acquired the anatomical knowledge only via the dissection course. Exposure (MSUS and ASK) took place in two separate lessons (75 minutes each, shoulder and knee joint) and introduced standard scan planes using a 10-MHz ultrasound system as well as arthroscopy tutorials at a simulator combined with video tutorials. The theoretical anatomic learning outcomes were tested using a multiple-choice questionnaire (MCQ), and after cross-over an objective structured clinical examination (OSCE). Differences in student's perceptions were evaluated using Likert scale-based items. The ASK-group (n = 70, age 23.4 (20-36) yrs.) performed moderately better in the anatomical MC exam in comparison to the MSUS-group (n = 84, age 24.2 (20-53) yrs.) and the CON-group (n = 88, 22.8 (20-33) yrs.; p = 0.019). After an additional arthroscopy teaching 1% of students failed the MC exam, in contrast to 10% in the MSUS- or CON-group, respectively. The benefit of the ASK module was limited to the shoulder area (p < 0.001). The final examination (OSCE) showed no significant differences between any of the groups with good overall performances. In the evaluation, the students certified the arthroscopic tutorial a greater advantage concerning anatomical skills with higher spatial imagination in comparison to the ultrasound tutorial (p = 0.002; p < 0.001). The additional implementation of arthroscopy tutorials to the dissection course during the undergraduate anatomy training is profitable and attractive to students with respect to complex joint anatomy. Simultaneous teaching of basic-skills in musculoskeletal ultrasound should be performed by medical experts, but seems to be inferior to the arthroscopic 2D-3D-transformation, and is regarded by students as more difficult to learn. Although arthroscopy and ultrasound teaching do not have a major effect on learning joint anatomy, they have the potency to raise the interest in surgery.

  17. Arthroscopy or ultrasound in undergraduate anatomy education: a randomized cross-over controlled trial

    PubMed Central

    2012-01-01

    Background The exponential growth of image-based diagnostic and minimally invasive interventions requires a detailed three-dimensional anatomical knowledge and increases the demand towards the undergraduate anatomical curriculum. This randomized controlled trial investigates whether musculoskeletal ultrasound (MSUS) or arthroscopic methods can increase the anatomical knowledge uptake. Methods Second-year medical students were randomly allocated to three groups. In addition to the compulsory dissection course, the ultrasound group (MSUS) was taught by eight, didactically and professionally trained, experienced student-teachers and the arthroscopy group (ASK) was taught by eight experienced physicians. The control group (CON) acquired the anatomical knowledge only via the dissection course. Exposure (MSUS and ASK) took place in two separate lessons (75 minutes each, shoulder and knee joint) and introduced standard scan planes using a 10-MHz ultrasound system as well as arthroscopy tutorials at a simulator combined with video tutorials. The theoretical anatomic learning outcomes were tested using a multiple-choice questionnaire (MCQ), and after cross-over an objective structured clinical examination (OSCE). Differences in student’s perceptions were evaluated using Likert scale-based items. Results The ASK-group (n = 70, age 23.4 (20–36) yrs.) performed moderately better in the anatomical MC exam in comparison to the MSUS-group (n = 84, age 24.2 (20–53) yrs.) and the CON-group (n = 88, 22.8 (20–33) yrs.; p = 0.019). After an additional arthroscopy teaching 1% of students failed the MC exam, in contrast to 10% in the MSUS- or CON-group, respectively. The benefit of the ASK module was limited to the shoulder area (p < 0.001). The final examination (OSCE) showed no significant differences between any of the groups with good overall performances. In the evaluation, the students certified the arthroscopic tutorial a greater advantage concerning anatomical skills with higher spatial imagination in comparison to the ultrasound tutorial (p = 0.002; p < 0.001). Conclusions The additional implementation of arthroscopy tutorials to the dissection course during the undergraduate anatomy training is profitable and attractive to students with respect to complex joint anatomy. Simultaneous teaching of basic-skills in musculoskeletal ultrasound should be performed by medical experts, but seems to be inferior to the arthroscopic 2D-3D-transformation, and is regarded by students as more difficult to learn. Although arthroscopy and ultrasound teaching do not have a major effect on learning joint anatomy, they have the potency to raise the interest in surgery. PMID:22958784

  18. The diagnostic accuracy of physical examination compared to lung ultrasound for determining lung congestion in hemodialysis patients who have reached their dry weight

    NASA Astrophysics Data System (ADS)

    Rahardjo, K. D.; Dharmaeizar; Nainggolan, G.; Harimurti, K.

    2017-08-01

    Research has shown that hemodialysis patients with lung congestion have high morbidity and mortality. Patients were assumed to be free of lung congestion if they had reached their post-dialysis dry weight. Most often, to determine if the patient was free of lung congestion, physical examination was used. However, the accuracy of physical examination in detecting lung congestion has not been established. To compare the capabilities of physical examination and lung ultrasound in detection of lung congestion, cross-sectional data collection was conducted on hemodialysis patients. Analysis was done to obtain proportion, sensitivity, specificity, positive predictive value, negative predictive value, and positive likelihood ratio. Sixty patients participated in this study. The inter observer variation of 20 patients revealed a kappa value of 0.828. When all 60 patients were taken into account, we found that 36 patients (57.1%) had lung congestion. Mild lung congestion was found in 24 (38.1%), and 12 (19%) had a moderate degree of congestion. In the analysis comparing jugular venous pressure to lung ultrasound, we found that sensitivity was 0.47 (0.31-0.63), specificity was 0.73 (0.54-0.86), positive predictive value (PPV) was 0.51 (0.36-0.67), negative predictive value (NPV) was 0.70 (0.49-0.84), positive likelihood ratio (PLR) was 1.75 (0.88-3.47), and the negative likelihood ratio (NLR) was 0.72 (0.47-1.12). In terms of lung auscultation, we found that sensitivity was 0.56 (0.39-0.71), specificity was 0.54 (0.35-0.71), PPV was 0.61 (0.44-0.76), NPV was 0.48 (0.31-0.66), PLR was 1.21 (0.73-2.0), and NLR was 0.82 (0.49-1.38). The results of our study showed that jugular venous distention and lung auscultation examination are not reliable means of detecting lung congestion.

  19. CAN ULTRASOUND ABDOMEN HELP IN EARLY DIAGNOSIS OF DIABETES MELLITUS? AN OBSERVATIONAL STUDY.

    PubMed

    Anwar, Javed; Aamir, Muhammad Omer; Sanaullah; Imdad, Zeeshan ul Hasnain; Parveen, Ishrat; Yousaf, Nasreen

    2015-01-01

    Diabetes mellitus is a common disease. Similarly, ultrasound findings of fatty change and renal crystals are commonly seen on ultrasound. In the personal observation of the main author over the past so many years it was noticed that Diabetes Mellitus, Fatty liver and renal crystals all sit well together. This study tries to establish a relationship between diabetes mellitus renal echogenic foci and fatty liver. This study is first of its kind, as nobody has ever before investigated an association between the renal echogenic foci and fatty liver in relation to diabetes mellitus. This cross-sectional, observational study was conducted at Radiology Department Combined Military Hospital, Kohat From 2nd June 2013 to 30th May 2014. Three hundred patients were collected on the basis of having fatty liver and renal echogenic foci on ultrasound and three hundred more patients were collected who had no fatty liver or renal echogenic foci on ultrasound. Their labs were done for diabetes mellitus. The patients having renal echogenic foci together with fatty liver had 83% positive rate of being diabetics, while patients with no fatty liver and no echogenic foci on ultrasonography had only 0.6% Positive rate of being diabetics. Our results provided the first demonstration of an association between renal echogenic foci together with fatty liver with the diabetes mellitus. Thus ultrasound examination of abdomen can be helpful in its early diagnosis if we make a protocol of doing fasting and random blood sugars in all those patients who have positive renal echogenic foci and fatty liver on their ultrasound examination.

  20. Ultrahigh field magnetic resonance and colour Doppler real-time fusion imaging of the orbit--a hybrid tool for assessment of choroidal melanoma.

    PubMed

    Walter, Uwe; Niendorf, Thoralf; Graessl, Andreas; Rieger, Jan; Krüger, Paul-Christian; Langner, Sönke; Guthoff, Rudolf F; Stachs, Oliver

    2014-05-01

    A combination of magnetic resonance images with real-time high-resolution ultrasound known as fusion imaging may improve ophthalmologic examination. This study was undertaken to evaluate the feasibility of orbital high-field magnetic resonance and real-time colour Doppler ultrasound image fusion and navigation. This case study, performed between April and June 2013, included one healthy man (age, 47 years) and two patients (one woman, 57 years; one man, 67 years) with choroidal melanomas. All cases underwent 7.0-T magnetic resonance imaging using a custom-made ocular imaging surface coil. The Digital Imaging and Communications in Medicine volume data set was then loaded into the ultrasound system for manual registration of the live ultrasound image and fusion imaging examination. Data registration, matching and then volume navigation were feasible in all cases. Fusion imaging provided real-time imaging capabilities and high tissue contrast of choroidal tumour and optic nerve. It also allowed adding a real-time colour Doppler signal on magnetic resonance images for assessment of vasculature of tumour and retrobulbar structures. The combination of orbital high-field magnetic resonance and colour Doppler ultrasound image fusion and navigation is feasible. Multimodal fusion imaging promises to foster assessment and monitoring of choroidal melanoma and optic nerve disorders. • Orbital magnetic resonance and colour Doppler ultrasound real-time fusion imaging is feasible • Fusion imaging combines the spatial and temporal resolution advantages of each modality • Magnetic resonance and ultrasound fusion imaging improves assessment of choroidal melanoma vascularisation.

  1. Accelerated Training at Mach 20: A Brief Communication Submitted from the International Space Station

    NASA Technical Reports Server (NTRS)

    Foale, C. Michael; Kaleri, Alexander Y.; Sargsyan, Ashot E.; Hamilton, Douglas R.; Melton, Shannon; Martin, David; Dulchavsky, Scott A.

    2004-01-01

    The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed just-in-time training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This just-in-time concept was used to support real-time remote expert guidance to complete medical examinations using the ISS Human Research Facility (HRF). An American and Russian ISS crewmember received 2-hours of hands on ultrasound training 8 months prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember six days prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. Results of the CD ROM based OPE session were used to modify the instructions during a complete 35 minute real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were excellent and adequate for clinical decision-making. Complex ultrasound experiments with expert guidance were performed with high accuracy following limited pre-flight training and CD-ROM-based in-flight review, despite a 2-second communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, can facilitate the performance of complex demanding tasks.

  2. Assessment and classification of fistula-in-ano in patients with Crohn's disease by hydrogen peroxide enhanced transanal ultrasound.

    PubMed

    Sloots, C E; Felt-Bersma, R J; Poen, A C; Cuesta, M A; Meuwissen, S G

    2001-09-01

    Crohn's disease is well known for its perianal complications, among which fistulas-in-ano are the most common abnormalities. Fistulas-in-ano in Crohn's disease tend to be complex and have a high recurrence rate. Therefore the role of surgery is generally more conservative. Hydrogen peroxide enhanced transanal ultrasound has proven superior to physical examination, fistulography, computed tomography, and conventional ultrasound in demonstrating the fistula tract. This study examined the fistula tracks in patients with Crohn's disease. Forty-one patients with Crohn's disease and fistula-in-ano were investigated using physical examination, sondage of the fistula, proctoscopy and transanal ultrasound. Hydrogen peroxide was infused via a small catheter into the fistula. The main track and the ramification of the fistula were classified according to the anatomical Parks' classification. Only 9 (22%) patients had a single inter- or transsphincteric fistula. In 5 (12%) patients a single supra- or extrasphincteric fistula (high fistula) was found, in 14 (34%) more than one fistula track (ramified), and in 13 (32%) an anovaginal fistula. Thus 78% of patients had a surgically difficult to treat fistula. In the ramified fistula the main track follows the Parks' classification, but ramifications can have a bizarre pattern which is not in agreement with this classification. Optimal documentation by means of hydrogen peroxide enhanced transanal ultrasound is therefore mandatory before surgery or before other therapies such as anti-tumor necrosis factor treatment.

  3. Progressive Muscle Atrophy and Weakness After Treatment by Mantle Field Radiotherapy in Hodgkin Lymphoma Survivors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leeuwen-Segarceanu, Elena M. van, E-mail: e.segarceanu@antoniusziekenhuis.nl; Dorresteijn, Lucille D.A.; Pillen, Sigrid

    Purpose: To describe the damage to the muscles and propose a pathophysiologic mechanism for muscle atrophy and weakness after mantle field radiotherapy in Hodgkin lymphoma (HL) survivors. Methods and Materials: We examined 12 patients treated by mantle field radiotherapy between 1969 and 1998. Besides evaluation of their symptoms, the following tests were performed: dynamometry; ultrasound of the sternocleidomastoid, biceps, and antebrachial flexor muscles; and needle electromyography of the neck, deltoid, and ultrasonographically affected arm muscles. Results: Ten patients (83%) experienced neck complaints, mostly pain and muscle weakness. On clinical examination, neck flexors were more often affected than neck extensors. Onmore » ultrasound, the sternocleidomastoid was severely atrophic in 8 patients, but abnormal echo intensity was seen in only 3 patients. Electromyography of the neck muscles showed mostly myogenic changes, whereas the deltoid, biceps, and antebrachial flexor muscles seemed to have mostly neurogenic damage. Conclusions: Many patients previously treated by mantle field radiotherapy develop severe atrophy and weakness of the neck muscles. Neck muscles within the radiation field show mostly myogenic damage, and muscles outside the mantle field show mostly neurogenic damage. The discrepancy between echo intensity and atrophy suggests that muscle damage is most likely caused by an extrinsic factor such as progressive microvascular fibrosis. This is also presumed to cause damage to nerves within the radiated field, resulting in neurogenic damage of the deltoid and arm muscles.« less

  4. The TERESA project: from space research to ground tele-echography

    NASA Technical Reports Server (NTRS)

    Vieyres, Pierre; Poisson, Gerard; Courreges, Fabien; Merigeaux, Olivier; Arbeille, Philippe

    2003-01-01

    Ultrasound examinations represent one of the major diagnostic modalities of future healthcare. They are currently used to support medical space research but require a high skilled operator for both probe positioning on the patient's skin and image interpretation. TERESA is a tele-echography project that proposes a solution to bring astronauts and remotely located patients on ground quality ultrasound examinations despite the lack of a specialist at the location of the wanted medical act.

  5. The ultrasound-assisted physical examination in the periodic health evaluation of the elderly.

    PubMed

    Siepel, T; Clifford, D S; James, P A; Cowan, T M

    2000-07-01

    Except for specific procedures such as blood pressure measurement, the conventional physical examination (PE) does not have sufficient sensitivity to be useful as part of the periodic health evaluation. Ultrasound has demonstrated greater sensitivity and specificity in numerous studies but has been too expensive to be widely employed in health screening. The purpose of our study was to determine whether an examination in which conventional and ultrasound techniques are blended and applied by a primary care physician might be feasible and useful in the periodic health evaluations of senior citizens. Seventy-two patients presenting to a community-based family physician for periodic health evaluations received an ultrasound-assisted physical examination (USA-PE) from a second family physician. The results were reported to the primary physician, and the outcomes were tracked for periods of up to 2 years. Twenty-two of the 72 patients (31%) had abnormalities found by the USA-PE that were not apparent during the conventional PE. Five of these patients (7%) had serious conditions that received prompt treatment with apparent benefit. Findings included endometrial carcinoma, abdominal aortic aneurysm, carotid stenosis, hydronephrosis, and urinary retention. The USA-PE found more abnormalities in this group of patients than conventional PE. Whether it can improve outcomes for senior citizens undergoing periodic health evaluations in a cost-effective manner is yet to be determined.

  6. Transcranial focused ultrasound stimulation of human primary visual cortex

    NASA Astrophysics Data System (ADS)

    Lee, Wonhye; Kim, Hyun-Chul; Jung, Yujin; Chung, Yong An; Song, In-Uk; Lee, Jong-Hwan; Yoo, Seung-Schik

    2016-09-01

    Transcranial focused ultrasound (FUS) is making progress as a new non-invasive mode of regional brain stimulation. Current evidence of FUS-mediated neurostimulation for humans has been limited to the observation of subjective sensory manifestations and electrophysiological responses, thus warranting the identification of stimulated brain regions. Here, we report FUS sonication of the primary visual cortex (V1) in humans, resulting in elicited activation not only from the sonicated brain area, but also from the network of regions involved in visual and higher-order cognitive processes (as revealed by simultaneous acquisition of blood-oxygenation-level-dependent functional magnetic resonance imaging). Accompanying phosphene perception was also reported. The electroencephalo graphic (EEG) responses showed distinct peaks associated with the stimulation. None of the participants showed any adverse effects from the sonication based on neuroimaging and neurological examinations. Retrospective numerical simulation of the acoustic profile showed the presence of individual variability in terms of the location and intensity of the acoustic focus. With exquisite spatial selectivity and capability for depth penetration, FUS may confer a unique utility in providing non-invasive stimulation of region-specific brain circuits for neuroscientific and therapeutic applications.

  7. Utility of intravascular ultrasound examination during carotid stenting.

    PubMed

    Joan, M Mellado; Moya, B Gómez; Agustí, F Pañella; Vidal, R García; Arjona, Y Abril; Alija, M P Fariñas; Paredero, V Martín

    2009-01-01

    Intravascular ultrasound (IVUS) examination may provide useful information during endovascular procedures. However, its actual clinical utility for carotid stenting remains unclear. We evaluated the usefulness of IVUS as a complementary tool during endovascular procedures in the carotid arteries and its impact on the modification of the therapeutic strategy. Between April 2006 and April 2007, 18 symptomatic patients (nine with transient ischemic attack, nine with stroke) underwent angioplasty and stenting of >70% stenosis of the internal carotid artery (ICA). Target lesions were identified with preoperative duplex scanning and further confirmed at angiography. Intraoperative IVUS examination was performed in all patients. Multilevel measurement of the artery as well as virtual histology images, before and after stenting, were obtained. The technique was 100% successful. There were no complications at the femoral puncture site and no neurological or other events. Compared with angiography, IVUS findings showed an average arterial diameter that was greater than 1.64+/-0.22mm. Based on virtual histology information, endovascular treatment was excluded in two patients and carotid endarterectomy was performed. Type or size of the stent was modified after IVUS examination in eight cases. IVUS examination provides complementary information to that obtained using conventional diagnostic procedures. It may be useful for characterizing the composition and measurement of the target lesion, choosing the type and size of the stent, and evaluating the results after the procedure.

  8. Photoacoustic and ultrasound characterization of bone composition

    NASA Astrophysics Data System (ADS)

    Lashkari, Bahman; Yang, Lifeng; Liu, Lixian; Tan, Joel W. Y.; Mandelis, Andreas

    2015-02-01

    This study examines the sensitivity and specificity of backscattered ultrasound (US) and backscattering photoacoustic (PA) signals for bone composition variation assessment. The conventional approach in the evaluation of bone health relies on measurement of bone mineral density (BMD). Although, a crucial and probably the most important parameter, BMD is not the only factor defining the bone health. New trends in osteoporosis research, also pursue the changes in collagen content and cross-links with bone diseases and aging. Therefore, any non-invasive method that can assess any of these parameters can improve the diagnostic tools and also can help with the biomedical studies on the diseases themselves. Our previous studies show that both US and PA are responsive to changes in the BMD, PA is, in addition, sensitive to changes in the collagen content of the bone. Measurements were performed on bone samples before and after mild demineralization and decollagenization at the exact same points. Results show that combining both modalities can enhance the sensitivity and specificity of diagnostic tool.

  9. Bowel ultrasound imaging in patients with cystic fibrosis: Relationship with clinical symptoms and CFTR genotype.

    PubMed

    Fraquelli, Mirella; Baccarin, Alessandra; Corti, Fabiola; Conti, Clara Benedetta; Russo, Maria Chiara; Della Valle, Serena; Pozzi, Roberta; Cressoni, Massimo; Conte, Dario; Colombo, Carla

    2016-03-01

    Ultrasound imaging is used to assess bowel abnormalities in gastrointestinal diseases. We aimed to assess the rate of predefined bowel ultrasound signs and their relationship with gastrointestinal symptoms and the cystic fibrosis transmembrane conductance regulator (CFTR) genotype in cystic fibrosis patients in regular follow-up. Prospective study of 70 consecutive patients with cystic fibrosis and 45 controls who underwent abdominal ultrasound; pertinent findings were related to gastrointestinal symptoms and, in cystic fibrosis patients, to pancreatic status, malabsorption degree, lipase intake, CFTR genotype (classified as severe or mild against functional class of CFTR mutations). 96% patients showed at least one abnormal bowel ultrasound sign. Most frequent signs were lymph node enlargement (64%), bowel loop dilatation (55%), thick corpuscular intraluminal content (49%), bowel wall hypervascularization (26%), thickened bowel wall (22%) and intussusception (17%). Patients with recurrent abdominal pain showed more bowel wall hypervascularization than patients without recurrent pain (47% vs. 19%, respectively; p = 0.02) and intussusception (58% vs. 17%, respectively; p < 0.01). Genotype was not associated to specific bowel ultrasound signs. Patients with bowel loop intussusception showed greater lipase intake than those without intussusception (8.118 ± 2.083 vs. 5.994 ± 4.187, respectively; p < 0.01). Cystic fibrosis patients present a higher rate of bowel ultrasound abnormalities than controls. Bowel ultrasound abnormalities are associated with abdominal symptoms. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. CT biliary cystoscopy of gallbladder polyps

    PubMed Central

    Lou, Ming-Wu; Hu, Wei-Dong; Fan, Yi; Chen, Jin-Hua; E, Zhan-Sen; Yang, Guang-Fu

    2004-01-01

    AIM: CT virtual endoscopy has been used in the study of various organs of body including the biliary tract, however, CT virtual endoseopy in diagnosis of gallbladder polyps has not yet been reported. This study was to evaluate the diagnostic value of CT virtual endoscopy in polyps of the gallbladder. METHODS: Thirty-two cases of gallbladder polyps were examined by CT virtual endoscopy, ultrasound, CT scan with oral biliary contrast separately and confirmed by operation and pathology. CT biliary cystoscopic findings were analyzed and compared with those of ultrasound and CT scan with oral biliary contrast, and evaluated in comparison with operative and pathologic findings in all cases. RESULTS: The detection rate of gallbladder polyps was 93.8%(90/96), 96.9%(93/96) and 79.2%(76/96) for CT cystoscopy, ultrasound and CT scan with oral contrast, respectively. CT biliary cystoscopy corresponded well with ultrasound as well as pathology in demonstrating the location, size and configuration of polyps. CT endoscopy was superior to ultrasound in viewing the polyps in a more precise way, 3 dimensionally from any angle in space, and showing the surface in details. CT biliary cystoscopy was also superior to CT scan with oral biliary contrast in terms of observation of the base of polyps for the presence of a pedicle, detection rates as well as image quality. The smallest polyp detected by CT biliary cystoscopy was measured 1.5 mm×2.2 mm×2.5 mm. CONCLUSION: CT biliary cystoscopy is a non-invasive and accurate technique for diagnosis and management of gallbladder polyps. PMID:15069726

  11. Clinical and sonographic risk factors and complications of shoulder dystocia - a case-control study with parity and gestational age matched controls.

    PubMed

    Parantainen, Jukka; Palomäki, Outi; Talola, Nina; Uotila, Jukka

    2014-06-01

    To examine the clinical risk factors and complications of shoulder dystocia today and to evaluate ultrasound methods predicting it. Retrospective, matched case-control study at a University Hospital with 5000 annual deliveries. The study population consisted of 152 deliveries complicated by shoulder dystocia over a period of 8.5 years (January 2004-June 2012) and 152 controls matched for gestational age and parity. The data was collected from the medical records of mothers and children and analyzed by conditional logistic regression. Incidences and odds ratios were calculated for risk factors and complications. Antenatal ultrasound data was analyzed when available by conditional logistic regression to test for significant differences between study groups. Birthweight (OR 12.1 for ≥4000 g; 95% CI 4.18-35.0) and vacuum extraction (OR 3.98; 95% CI 1.25-12.7) remained the most significant clinical risk factors. Only a trend of an association of pregestational or gestational diabetes was noticed (OR 1.87; 95% CI 0.997-3.495, probability of type II error 51%). Of the complications of shoulder dystocia the incidence of brachial plexus palsies was high (40%). Antenatal ultrasound method based on the difference between abdominal and biparietal diameters had a significant difference between cases and controls. The impact of diabetes as a risk factor has diminished, which may reflect improved screening and treatment. Antenatal ultrasound methods are showing some promise, but the predictive value of ultrasound alone is probably low. Copyright © 2014. Published by Elsevier Ireland Ltd.

  12. Effects of Student-Performed Point-of-Care Ultrasound on Physician Diagnosis and Management of Patients in the Emergency Department.

    PubMed

    Udrea, Daniel S; Sumnicht, Andrew; Lo, Deanna; Villarreal, Logan; Gondra, Stephanie; Chyan, Richard; Wisham, Audra; Dinh, Vi Am

    2017-07-01

    Despite the increasing integration of ultrasound training into medical education, there is an inadequate body of research demonstrating the benefits and practicality of medical student-performed point-of-care ultrasound (SP-POCUS) in the clinical setting. The primary purpose of this study was to evaluate the effects that SP-POCUS can have on physician diagnosis and management of patients in the emergency department, with a secondary purpose of evaluating the diagnostic accuracy of SP-POCUS. SP-POCUS examinations were performed in the emergency department by medical students who completed year one of a 4-year medical school curriculum with integrated ultrasound training. Scans were evaluated by an emergency physician who then completed a survey to record any changes in diagnosis and management. A total of 641 scans were performed on the 482 patients enrolled in this study. SP-POCUS resulted in a change in management in 17.3% of scans performed. For 12.4% of scans, SP-POCUS discovered a new diagnosis. SP-POCUS reduced time to disposition 33.5% of the time. Because of SP-POCUS, physicians avoided ordering an additional imaging study for 53.0% of the scans performed. There was 94.7% physician agreement with SP-POCUS diagnosis. This study showed that SP-POCUS is feasible and may potentially have a meaningful impact on physician diagnosis and management of patients in the emergency department. In addition, the implementation of SP-POCUS could serve as an ideal method of developing ultrasound skills in medical school while positively impacting patient care. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Ultrasound-Guided Intratendinous Injections With Platelet-Rich Plasma or Autologous Whole Blood for Treatment of Proximal Hamstring Tendinopathy: A Double-Blind Randomized Controlled Trial.

    PubMed

    Davenport, Kathleen L; Campos, Jose Santiago; Nguyen, Joseph; Saboeiro, Gregory; Adler, Ronald S; Moley, Peter J

    2015-08-01

    To compare the effects of ultrasound-guided platelet-rich plasma (PRP) and whole blood (WB) injections in patients with chronic hamstring tendinopathy. In a prospective double-blind randomized controlled trial, PRP or WB was injected under ultrasound guidance into the proximal hamstring tendon in a cohort of patients with clinically suspected hamstring tendinosis. Questionnaires were administered before injection and 2, 6, and 12 weeks and 6 months after injection. Pain and function outcomes were measured via the Modified Harris Hip Score (MHHS), Hip Outcome Scores for activities of daily living (ADL) and sport-specific function, and International Hip Outcome Tool 33 (IHOT-33). Diagnostic ultrasound was used to compare preinjection and 6-month postinjection tendon appearances. The WB group showed greater improvements in pain and function over the PRP group before 12 weeks, whereas the PRP group showed improved outcomes over WB at 6 months. None of these between-group outcome measures, except 6-week IHOT-33, showed statistical significance. Comparing preinjection and 6-month scores, the PRP group showed significant improvements in ADL (P = .018) and IHOT-33 (P = .28) scores, whereas the WB group showed no significant improvements from baseline. The WB group showed significantly decreased pain with 15-minute sitting (P= .008) at 6 months. Ultrasound imaging showed no significant differences between PRP and WB group tendon appearances. Both PRP and WB groups showed improvements in all outcome measures at 6 months. The PRP group showed significant improvements in 6-month ADL and IHOT-33 scores. The WB group reached significance in 15-minute sitting pain. No significant between-group differences were observed at any time point. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Is it necessary to perform prophylactic cholecystectomy for all symptomatic gallbladder polyps diagnosed with ultrasound?

    PubMed

    Velidedeoğlu, Mehmet; Çitgez, Bülent; Arıkan, Akif Enes; Ayan, Fadıl

    2017-01-01

    The main aim of this study is to determine the necessity of cholecystectomy in patients with ultrasound diagnosed symptomatic polypoid lesions of the gallbladder. The data of 82 patients with polypoid lesions of the gallbladder who had cholecystectomy between 2000 and 2012 were analyzed retrospectively with preoperative ultrasound and histopathology results. The mean age was 48.05±11.18 years (range 25-74 years). All patients underwent preoperative ultrasound examination. Eighteen (22%) of the 82 patients were asymptomatic; their polypoid lesions of the gallbladder were detected with ultrasound during a check-up or other reasons. In 45 (55%) of cases pathology reported no polypoid lesions of the gallbladder. Right upper quadrant or epigastric pain was the most common symptom (41.46%) that led to hepatobiliary ultrasound, the other symptom was dyspepsia (36.59%). On preoperative ultrasound evaluation, 22 patients had multiple polyps, and 9 of these 22 patients had at least 3 polyps. There is an inaccuracy of ultrasound to detect polypoid lesions of the gallbladder. After diagnosing polypoid lesions of the gallbladder by using standard ultrasound, further pre-operative diagnostic tests are needed to help discriminating benign lesions from malignant ones, which may prevent unnecessary surgery regardless of symptoms.

  15. Petroleum Jelly: A Novel Medium for Ocular Ultrasound.

    PubMed

    Engelbert, Patrick R; Palma, James K

    2015-08-01

    Ocular ultrasound is a useful emergency department imaging modality for evaluation of many conditions, such as retinal detachment, vitreous detachment, vitreous hemorrhage, and elevated intracranial pressure. Obtaining satisfactory ocular ultrasound images requires the use of a medium that eliminates the air interface between the patient's eye and the transducer. Ultrasound gel is most commonly used; however, the use of a transparent dressing applied to the closed eye prior to the application of gel has also been described as a suitable technique. Ocular ultrasound is performed with the high-frequency linear array transducer using a medium to eliminate the air interface between the eye and the transducer. Although ultrasound gel is most frequently used, it can cause minor eye irritation. Placing a transparent dressing over a closed eye prior to application of gel can eliminate the eye irritation. However, our experience in training >500 students in ocular ultrasound has shown that air is frequently introduced underneath the dressing, which leads to poor-quality images. This article introduces petroleum jelly as a medium for ocular ultrasound. By applying a layer of petroleum jelly over the closed eye and allowing it to warm via body heat for 30 to 45 s, this medium can both minimize patient discomfort and provide easily obtainable, high-quality ocular ultrasound images. This article introduces petroleum jelly as a safe, comfortable, and effective medium for ocular ultrasound examination. Published by Elsevier Inc.

  16. The ultrasound unit and infection control – Are we on the right track?

    PubMed Central

    Westerway, Susan C

    2017-01-01

    Best practice guidelines for the disinfection of ultrasound transducers and infection prevention in ultrasound departments are generally recommended by either government health groups or the ultrasound societies of individual countries. The literature shows a wide variance in not only transducer cleaning methods but basic hygiene practices in the ultrasound workplace. This paper describes results from a UK survey of disinfection of ultrasound transducers and hygiene practice in the workplace. The survey revealed that some ultrasound practitioners did not follow current guidelines with regard to the correct disinfection method of transducers, cords or ultrasound machine keyboards. Furthermore, the survey exposed the lack of training from the product manufacturers on how to use the disinfection product appropriately. These inconsistencies may be responsible for compliance issues and highlight the need for an awareness campaign and a unified approach to infection control by ultrasound practitioners. PMID:28228825

  17. Early pregnancy diagnosis on days 18 to 21 postinsemination using high-resolution imaging in lactating dairy cows.

    PubMed

    Scully, S; Butler, S T; Kelly, A K; Evans, A C O; Lonergan, P; Crowe, M A

    2014-01-01

    The aim was to assess the ability of corpus luteum (CL) and uterine ultrasound characteristics on d 18 to 21 to predict pregnancy status in lactating dairy cows. Ultrasound examinations were carried out on cows (n = 164) on d 18 to 21 following artificial insemination (AI). Images of the uterus and CL were captured using a Voluson i ultrasound device (General Electric Healthcare Systems, Vienna, Austria) equipped with a 12-MHz, multi frequency, linear array probe. Serum concentrations of progesterone were determined from blood samples collected at each ultrasound examination. Images of the CL were captured and stored for calculation of CL tissue area and echotexture. Images of the CL and associated blood flow area were captured and stored for analysis of luteal blood flow ratio. Longitudinal B-mode images of the uterine horns were stored for analysis of echotexture. Diagnosis of pregnancy was made at each ultrasound examination based on CL blood flow, CL size, and uterine echotexture. Pregnancy was confirmed by ultrasonography on d 30 after AI. The relationship between ultrasound measures and pregnancy outcome, as well as the accuracy of the pregnancy diagnosis made at each ultrasound examination was assessed. Progesterone concentrations and CL tissue area were greater in pregnant compared with nonpregnant cows on all days. The CL blood flow ratio was higher in pregnant compared with nonpregnant cows on d 20 and 21 after AI. Echotexture measures of the CL and uterus were not different between pregnant and nonpregnant cows on any day of examination. The best logistic regression model to predict pregnancy included scores for CL blood flow, CL size, and uterine echotexture on d 21 following AI. Accuracy of pregnancy diagnosis was highest on d 21, with sensitivity and specificity being 97.6 and 97.5%, respectively. Uterine echotexture scores were similar for pregnant and nonpregnant cows from d 18 to 20. On d 21, pregnant cows had higher uterine echotexture scores compared with nonpregnant cows. The logistic regression equation most likely to provide a correct pregnancy diagnosis in lactating dairy cows included the visual score for CL blood flow, CL size, and uterine echotexture on d 21 after AI. In support of this finding, the diagnostic accuracy for visual scores of CL blood flow, CL size, and uterine echotexture were also highest on d 21. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Reducing duplex examinations in patients with iatrogenic pseudoaneurysms.

    PubMed

    Stone, Patrick A; Aburahma, Ali F; Flaherty, Sarah K

    2006-06-01

    Ultrasound-guided thrombin injection has become the initial treatment of choice for femoral access-related pseudoaneurysms. Patients typically undergo serial duplex examinations to assess for spontaneous resolution of small iatrogenic pseudoaneurysms (IPSAs) (<2.5 cm), or may require repeated diagnostic, therapeutic, and follow-up studies for larger IPSAs (>2.5 cm). We evaluated the impact of a revised treatment algorithm that includes primary treatment of both small (<2.5 cm) and larger pseudoaneurysms (>2.5 cm), rather than observation of smaller ones, and attempts to establish a single duplex examination via a point-of-care treatment strategy. We reviewed 105 consecutive patients treated with ultrasound-guided thrombin injection from July 2001 through September 2004. Patient, IPSAs, characteristics, and treatment methods were examined. The number of duplex examinations per patient was evaluated over the treatment interval. Also, published cost data were used to compare primary treatment of small ISPAs vs observation with serial duplex examinations. Successful thrombosis occurred in 103 (98.1%) of 105 treated pseudoaneurysms. No minor or major complications occurred after thrombin injection in either small or large ISPAs, and both failures requiring operation were in the large aneurysm group. The recurrence rate for the series was 1.9% (2/105), and both recurrences were successfully treated with an additional thrombin injection. A single injection was successful in treating 43 (97.7%) of 44 small (<2.5 cm) IPSAs, and one required a second injection. Patients had an average of 3.3 duplex examinations in our first year of treatment experience, which declined to 1.5 by our third year with the institution of a point-of-care service model for all pseudoaneurysms. Based on this decreased use of duplex examination and an average treatment cohort of 35 IPSA patients per year our institution, we determined this results in a reduction of 35 hours of laboratory time and nearly 70 ultrasounds per year. Similarly for small pseudoaneurysms, a point-of-service primary treatment program rather than observation results in an estimated cost savings of $12,000, based on treating 15 small IPSAs per year. Ultrasound-guided thrombin injection is safe and effective for the treatment of nearly all iatrogenic pseudoaneurysms. We recommend primary treatment of small pseudoaneurysms by ultrasound-guided thrombin injection rather than observation with serial duplex scans. A point-of-care treatment algorithm can result in cost savings by reducing the number of necessary duplex examinations.

  19. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    PubMed

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p < 0.001 and p = 0.009, respectively) and MRI (p = 0.045 and p = 0.036, respectively). The percentage diameter decrease, size of tumour deposit in LN, progesterone receptor, HER2 and histological grade were significantly associated with the diagnostic performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with diagnostic performance of ultrasound and PET/CT. This study is about the diagnostic performance of ultrasound, MRI, PET/CT and combination of each imaging modality for the evaluation of metastatic ALN after NAC. Of many histopathological factors, only the size of tumour deposit within ALN was an independent factor associated with the diagnostic performance of ultrasound and PET/CT.

  20. Design and characterization of a high-power ultrasound driver with ultralow-output impedance

    NASA Astrophysics Data System (ADS)

    Lewis, George K.; Olbricht, William L.

    2009-11-01

    We describe a pocket-sized ultrasound driver with an ultralow-output impedance amplifier circuit (less than 0.05 Ω) that can transfer more than 99% of the voltage from a power supply to the ultrasound transducer with minimal reflections. The device produces high-power acoustical energy waves while operating at lower voltages than conventional ultrasound driving systems because energy losses owing to mismatched impedance are minimized. The peak performance of the driver is measured experimentally with a PZT-4, 1.54 MHz, piezoelectric ceramic, and modeled using an adjusted Mason model over a range of transducer resonant frequencies. The ultrasound driver can deliver a 100 Vpp (peak to peak) square-wave signal across 0-8 MHz ultrasound transducers in 5 ms bursts through continuous wave operation, producing acoustic powers exceeding 130 W. Effects of frequency, output impedance of the driver, and input impedance of the transducer on the maximum acoustic output power of piezoelectric transducers are examined. The small size, high power, and efficiency of the ultrasound driver make this technology useful for research, medical, and industrial ultrasonic applications.

  1. Thoracic ultrasound: Potential new tool for physiotherapists in respiratory management. A narrative review.

    PubMed

    Le Neindre, Aymeric; Mongodi, Silvia; Philippart, François; Bouhemad, Bélaïd

    2016-02-01

    The use of diagnostic ultrasound by physiotherapists is not a new concept; it is frequently performed in musculoskeletal physiotherapy. Physiotherapists currently lack accurate, reliable, sensitive, and valid measurements for the assessment of the indications and effectiveness of chest physiotherapy. Thoracic ultrasound may be a promising tool for the physiotherapist and could be routinely performed at patients' bedsides to provide real-time and accurate information on the status of pleura, lungs, and diaphragm; this would allow for assessment of lung aeration from interstitial syndrome to lung consolidation with much better accuracy than chest x-rays or auscultation. Diaphragm excursion and contractility may also be assessed by ultrasound. This narrative review refers to lung and diaphragm ultrasound semiology and describes how physiotherapists could use this tool in their clinical decision-making processes in various cases of respiratory disorders. The use of thoracic ultrasound semiology alongside typical examinations may allow for the guiding, monitoring, and evaluating of chest physiotherapy treatments. Thoracic ultrasound is a potential new tool for physiotherapists. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Cavitation thresholds of contrast agents in an in vitro human clot model exposed to 120-kHz ultrasound.

    PubMed

    Gruber, Matthew J; Bader, Kenneth B; Holland, Christy K

    2014-02-01

    Ultrasound contrast agents (UCAs) can be employed to nucleate cavitation to achieve desired bioeffects, such as thrombolysis, in therapeutic ultrasound applications. Effective methods of enhancing thrombolysis with ultrasound have been examined at low frequencies (<1 MHz) and low amplitudes (<0.5 MPa). The objective of this study was to determine cavitation thresholds for two UCAs exposed to 120-kHz ultrasound. A commercial ultrasound contrast agent (Definity(®)) and echogenic liposomes were investigated to determine the acoustic pressure threshold for ultraharmonic (UH) and broadband (BB) generation using an in vitro flow model perfused with human plasma. Cavitation emissions were detected using two passive receivers over a narrow frequency bandwidth (540-900 kHz) and a broad frequency bandwidth (0.54-1.74 MHz). UH and BB cavitation thresholds occurred at the same acoustic pressure (0.3 ± 0.1 MPa, peak to peak) and were found to depend on the sensitivity of the cavitation detector but not on the nucleating contrast agent or ultrasound duty cycle.

  3. Design and characterization of a high-power ultrasound driver with ultralow-output impedance.

    PubMed

    Lewis, George K; Olbricht, William L

    2009-11-01

    We describe a pocket-sized ultrasound driver with an ultralow-output impedance amplifier circuit (less than 0.05 ohms) that can transfer more than 99% of the voltage from a power supply to the ultrasound transducer with minimal reflections. The device produces high-power acoustical energy waves while operating at lower voltages than conventional ultrasound driving systems because energy losses owing to mismatched impedance are minimized. The peak performance of the driver is measured experimentally with a PZT-4, 1.54 MHz, piezoelectric ceramic, and modeled using an adjusted Mason model over a range of transducer resonant frequencies. The ultrasound driver can deliver a 100 V(pp) (peak to peak) square-wave signal across 0-8 MHz ultrasound transducers in 5 ms bursts through continuous wave operation, producing acoustic powers exceeding 130 W. Effects of frequency, output impedance of the driver, and input impedance of the transducer on the maximum acoustic output power of piezoelectric transducers are examined. The small size, high power, and efficiency of the ultrasound driver make this technology useful for research, medical, and industrial ultrasonic applications.

  4. Heart Rate Assessment Immediately after Birth.

    PubMed

    Phillipos, Emily; Solevåg, Anne Lee; Pichler, Gerhard; Aziz, Khalid; van Os, Sylvia; O'Reilly, Megan; Cheung, Po-Yin; Schmölzer, Georg M

    2016-01-01

    Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. PubMed, EMBASE and Google Scholar were systematically searched using the following terms: 'infant', 'heart rate', 'monitoring', 'delivery room', 'resuscitation', 'stethoscope', 'auscultation', 'palpation', 'pulse oximetry', 'electrocardiogram', 'Doppler ultrasound', 'photoplethysmography' and 'wearable sensors'. Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use. © 2015 S. Karger AG, Basel.

  5. Radio Frequency Ultrasound Time Series Signal Analysis to Evaluate High-intensity Focused Ultrasound Lesion Formation Status in Tissue.

    PubMed

    Mobasheri, Saeedeh; Behnam, Hamid; Rangraz, Parisa; Tavakkoli, Jahan

    2016-01-01

    High-intensity focused ultrasound (HIFU) is a novel treatment modality used by scientists and clinicians in the recent decades. This modality has had a great and significant success as a noninvasive surgery technique applicable in tissue ablation therapy and cancer treatment. In this study, radio frequency (RF) ultrasound signals were acquired and registered in three stages of before, during, and after HIFU exposures. Different features of RF time series signals including the sum of amplitude spectrum in the four quarters of the frequency range, the slope, and intercept of the best-fit line to the entire power spectrum and the Shannon entropy were utilized to distinguish between the HIFU-induced thermal lesion and the normal tissue. We also examined the RF data, frame by frame to identify exposure effects on the formation and characteristics of a HIFU thermal lesion at different time steps throughout the treatment. The results obtained showed that the spectrum frequency quarters and the slope and intercept of the best fit line to the entire power spectrum both increased two times during the HIFU exposures. The Shannon entropy, however, decreased after the exposures. In conclusion, different characteristics of RF time series signal possess promising features that can be used to characterize ablated and nonablated tissues and to distinguish them from each other in a quasi-quantitative fashion.

  6. A high-resolution 3D ultrasonic system for rapid evaluation of the anterior and posterior segment.

    PubMed

    Peyman, Gholam A; Ingram, Charles P; Montilla, Leonardo G; Witte, Russell S

    2012-01-01

    Traditional ultrasound imaging systems for ophthalmology employ slow, mechanical scanning of a single-element ultrasound transducer. The goal was to demonstrate rapid examination of the anterior and posterior segment with a three-dimensional (3D) commercial ultrasound system incorporating high-resolution linear probe arrays. The 3D images of the porcine eye were generated in approximately 10 seconds by scanning one of two commercial linear arrays (25- and 50-MHz). Healthy enucleated pig eyes were compared with those with induced injury or placement of a foreign material (eg, metal). Rapid, volumetric imaging was also demonstrated in one human eye in vivo. The 50-MHz probe provided exquisite volumetric images of the anterior segment at a depth up to 15 mm and axial resolution of 30 μm. The 25-MHz probe provided a larger field of view (lateral X depth: 20 × 30 mm), sufficient for capturing the entire anterior and posterior segments of the pig eye, at a resolution of 60 μm. A 50-MHz scan through the human eyelid illustrated detailed structures of the Meibomian glands, cilia, cornea, and anterior segment back to the posterior capsule. The 3D system with its high-frequency ultrasound arrays, fast data acquisition, and volume rendering capability shows promise for investigating anterior and posterior structures of the eye. Copyright 2012, SLACK Incorporated.

  7. Exploratory Analysis of Carbon Dioxide Levels and Ultrasound Measures of the Eye During ISS Missions

    NASA Technical Reports Server (NTRS)

    Schaefer, C.; Young, M.; Mason, S.; Coble, C.; Wear, M. L.; Sargsyan, A.; Garcia, K.; Law. J.; Alexander, D.; Ryder, V. Myers; hide

    2016-01-01

    Carbon dioxide (CO2) levels on ISS have typically averaged 2.3 to 5.3mm Hg, with large fluctuations occurring over periods of hours and days. CO2 has effects on cerebral vascular tone, resulting in vasodilation and alteration of cerebral blood flow(CBF). Increased CBF leads to elevated intracranial pressure(ICP), which is a factor leading to visual disturbance, headaches, and other central nervous system symptoms. Ultrasound of the optic nerve provides a surrogate measurement of ICP. Inflight ultrasounds were implemented as an enhanced screening tool for the Visual Impairment/Intracranial Pressure (VIIP) Syndrome. This analysis examines the relationships between ambient CO2 levels on ISS and ultrasound measures of the eye in an effort to understand how CO2 may be associated with VIIP and to inform future analysis of inflight VIIP data. Results as shown in Figure2, there was a large timeframe where CO2 readings were removed due to sensor fault errors(see Limitations), from June 2011 to January 2012. After extensive cleaning of the CO2 data, metrics for all of the data were calculated (Table2). Preliminary analyses showed possible associations between variability measures of CO2 and AP diameter (Figure3),and average CO2 exposure and ONSD(Figure4). Adjustments for multiple comparisons were not made due to the exploratory nature of the analysis.

  8. Effects of ultrasound-induced inertial cavitation on enzymatic thrombolysis.

    PubMed

    Chuang, Yueh-Hsun; Cheng, Po-Wen; Chen, Szu-Chia; Ruan, Jia-Ling; Li, Pai-Chi

    2010-04-01

    Cavitation induced by ultrasound enhances enzymatic fibrinolysis by increasing the transport of reactants. However, the effects of cavitation need to be fully understood before sonothrombolysis can be applied clinically. In order to understand the underlying mechanisms, we examined the effects of combining ultrasound, microbubbles and thrombolytic enzymes on thrombolysis. First, we evaluated the relations between inertial cavitation and the reduction in the weight of a blood clot. Inertial cavitation was varied by changing the amplitude and duration of the transmitted acoustic wave as well as the concentration of microbubbles used to induce cavitation. Second, we studied the combined effects of streptokinase and inertial cavitation on thrombolysis. The results show that inertial cavitation increases the weight reduction of a blood clot by up to 33.9%. With linear regression fitting, the measured differential inertial cavitation dose and the weight reduction had a correlation coefficient of 0.66. Microscopically, enzymatic thrombolysis effects manifest as multiple large cavities within the clot that are uniformly distributed on the side exposed to ultrasound. This suggests that inertial cavitation plays an important role in producing cavities, while microjetting of the microbubbles induces pits on the clot surface. These observations preliminarily demonstrate the clinical potential of sonothrombolysis. The use of the differential inertial cavitation dose as an indicator of blood clot weight loss for controlled sonothrombolysis is also possible and will be further explored.

  9. Degradation of polycyclic aromatic hydrocarbons (PAHs) in textile dyeing sludge with ultrasound and Fenton processes: Effect of system parameters and synergistic effect study.

    PubMed

    Lin, Meiqing; Ning, Xun-an; An, Taicheng; Zhang, Jianhao; Chen, Changmin; Ke, Yaowei; Wang, Yujie; Zhang, Yaping; Sun, Jian; Liu, Jingyong

    2016-04-15

    To establish an efficient oxidation process for the degradation of polycyclic aromatic hydrocarbons (PAHs) in textile dyeing sludge, the effects of various operating parameters were optimized during the ultrasound process, Fenton process and the combined ultrasound-Fenton process. The results showed that the ultrasonic density of 1.80w/cm(3), both H2O2 and Fe(2+) dosages of 140mmol/L and pH 3 were favorable conditions for the degradation of PAHs. The degradation efficiency of high molecular weight PAHs was close to or even higher than that of light molecular weight PAHs. The highest degradation efficiencies of Σ16 PAHs were obtained within 30min in the order of: Fenton (83.5%) >ultrasound-Fenton (75.5%) >ultrasound (45.5%), then the efficiencies were decreased in the other of: ultrasound-Fenton (73.0%) >Fenton (70.3%) >ultrasound (41.4%) in 60min. The extra PAHs were released from the intracellular substances and the cavities of sludge due to the disruption of sludge during the oxidation process. Also, the degradation of PAHs could be inhibited by the other organic matter in the sludge. The combined ultrasound-Fenton process showed more efficient than both ultrasound process and Fenton process not only in the surface of sludge but also in the sludge interior. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Point-of-care ultrasound diagnosis and treatment of posterior shoulder dislocation.

    PubMed

    Beck, Sierra; Chilstrom, Mikaela

    2013-02-01

    Acute traumatic posterior shoulder dislocations are rare. The diagnosis is often missed or delayed, as radiologic abnormalities can be subtle. We report a case of a 37-year-old man who presented to the emergency department with severe right shoulder pain and inability to move his arm after a motor vehicle collision. Based on examination, he was initially thought to have an anterior dislocation; however, point-of-care (POC) ultrasound clearly demonstrated a posterior shoulder dislocation. Real-time ultrasound-guided intra-articular local anesthetic injection facilitated closed reduction in the emergency department without procedural sedation, and POC ultrasound confirmed successful reduction at the bedside after the procedure. This case demonstrates that POC ultrasound can be a useful diagnostic tool in the rapid assessment and treatment for patients with suspected posterior shoulder dislocation. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Use of positive reinforcement conditioning to monitor pregnancy in an unanesthetized snow leopard (Uncia uncia) via transabdominal ultrasound.

    PubMed

    Broder, Jacqueline M; Macfadden, Annabell J; Cosens, Lindsay M; Rosenstein, Diana S; Harrison, Tara M

    2008-01-01

    Closely monitoring snow leopard (Uncia uncia) fetal developments via transabdominal ultrasound, with minimal stress to the animal, was the goal of this project. The staff at Potter Park Zoo has used the principles of habituation, desensitization, and positive reinforcement to train a female snow leopard (U. uncia). Ultrasound examinations were preformed on an unanesthetized feline at 63 and 84 days. The animal remained calm and compliant throughout both procedures. Fetuses were observed and measured on both occasions. The absence of anesthesia eliminated components of psychologic and physiologic stress associated with sedation. This was the first recorded instance of transabdominal ultrasound being carried out on an unanesthetized snow leopard. It documents the feasibility of detecting pregnancy and monitoring fetal development via ultrasound. Zoo Biol 27:78-85, 2008. (c) 2007 Wiley-Liss, Inc.

  12. A Preliminary Study on the Possibility of Using Ultrasound in Driver Assistance Systems

    NASA Astrophysics Data System (ADS)

    Takahashi, Hiroshi; Honda, Hirohiko

    This paper presents a preliminary study on the possibility of using ultrasound in driver assistance systems. Subjects' lap time in a driving video game was measured as an index of their performance of driving operations under acoustic conditions with and without an ultrasound signal at 23kHz, 70dB. The results show that the performance characteristics of the subjects changed when the ultrasound signal was presented. Ultrasound signal tends to concentrate on handling the vehicle and decreasing an attention to check the over speed driving, as a second task. We prove the possibility to apply ultrasound signal to control operator's attention and behavior.

  13. [Ultrasound examination for lower extremity deep vein thrombosis].

    PubMed

    Toyota, Kosaku

    2014-09-01

    Surgery is known to be a major risk factor of vein thrombosis. Progression from lower extremity deep vein thrombosis (DVT) to pulmonary embolism can lead to catastrophic outcome, although the incidence ratio is low. The ability to rule in or rule out DVT is becoming essential for anesthesiologists. Non-invasive technique of ultrasonography is a sensitive and specific tool for the assessment of lower extremity DVT. This article introduces the basics and practical methods of ultrasound examination for lower extremity DVT.

  14. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjonction: Comparison of radiographic, ultrasound and MRI findings.

    PubMed

    Faruch Bilfeld, Marie; Lapègue, Franck; Chiavassa Gandois, Hélène; Bayol, Marie Aurélie; Bonnevialle, Nicolas; Sans, Nicolas

    2017-02-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p < 0.0001). Ultrasound detected coracoclavicular ligament injuries with a sensitivity of 88.9 %, specificity of 90.0 %, positive predictive value of 92.3 % and negative predictive value of 85.7 %. The agreement between the ultrasound and radiography findings was poor, with a correlation coefficient of 0.69 (95 % CI: 0.51-0.82; p < 0.0001). Ultrasound is an effective examination for the diagnostic work-up of lesions of the coracoclavicular ligaments in the acute phase of an acromioclavicular injury. • Ultrasound is appropriate for acute acromioclavicular trauma due to its accessibility. • Ultrasound contributes to the diagnostic work-up of acute lesions of the coracoclavicular ligaments. • Ultrasound is appropriate in patients likely to benefit from surgical treatment. • Ultrasound could be a supplement to standard radiography in acute acromioclavicular trauma.

  15. First In Vivo Use of a Capacitive Micromachined Ultrasound Transducer Array–Based Imaging and Ablation Catheter

    PubMed Central

    Stephens, Douglas N.; Truong, Uyen T.; Nikoozadeh, Amin; Oralkan, Ömer; Seo, Chi Hyung; Cannata, Jonathan; Dentinger, Aaron; Thomenius, Kai; de la Rama, Alan; Nguyen, Tho; Lin, Feng; Khuri-Yakub, Pierre; Mahajan, Aman; Shivkumar, Kalyanam; O’Donnell, Matt; Sahn, David J.

    2012-01-01

    Objectives The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. Methods The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. Results The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. Conclusions Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures. PMID:22298868

  16. Applications of diagnostic ultrasonography in small ruminant reproductive management.

    PubMed

    Scott, P R

    2012-02-01

    Modern portable ultrasound machines provide the veterinary clinician with an inexpensive and non-invasive method to further examine the reproductive tract of both male and female sheep on farm which should take no more than 5 min with the results available immediately. Unlike cattle, ultrasound examination of the ovaries is not undertaken because failure to cycle during the normal season is rare in sheep and there are no common ovarian conditions causing acyclicity. Accurate diagnosis of foetal number has greatly improved the nutritional management of late gestation ewes over the past 30 years. Late gestation nutritional supply in response to foetal demand greatly reduces perinatal lamb mortality by ensuring lamb birthweight and ewe colostrum accumulation. The contents of vaginal prolapse have been determined using ultrasonography which has led to an improved method for correction. A retained foetus when second stage labour is considered to have been completed, and uterine torsion, can be identified during ultrasound examination allowing timely correction. Ultrasonographic examination of palpable scrotal abnormalities can provide much useful information particularly in the diagnosis of epididymitis, orchitis and testicular atrophy. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Ultrasound effects on the degradation kinetics, structure, and antioxidant activity of sea cucumber fucoidan.

    PubMed

    Guo, Xin; Ye, Xingqian; Sun, Yujing; Wu, Dan; Wu, Nian; Hu, Yaqin; Chen, Shiguo

    2014-02-05

    The effects of ultrasound on the molecular weight, structure, and antioxidant potential of a fucoidan found in Isostichopus badionotus were investigated. The results showed the molecular weight (Mw) of fucoidan decreased obviously after ultrasound treatment. Higher ultrasonic intensity, lower temperature, and lower fucoidan concentrations led to a more effective sonochemical effect. The kinetic model for fucoidan degradation fitted to 1/M(wt)-1/M(w0) = kt at the tested temperature. The optimized degradation conditions by response surface methodology (RSM) were temperature, 12 °C, and intensity, 508 W/cm². Structural analysis by FTIR and NMR indicated the fucoidan kept the linear tetrasaccharide repeating units as the original polysaccharides after the ultrasound treatment, with only slight destruction of the middle nonsulfated fucose units. Antioxidant activity assay showed the antioxidant activity was slightly improved by the ultrasound treatment. The results suggested that ultrasound treatment is an effective approach to decrease the M(w) of fucoidan with only minor structural destruction.

  18. Numerical Study on Focusing of Ultrasounds in Microbubble-enhanced HIFU

    NASA Astrophysics Data System (ADS)

    Matsumoto, Yoichiro; Okita, Kohei; Takagi, Shu

    2011-11-01

    The injection of microbubbles into the target tissue enhances tissue heating in High-Intensity Focused Ultrasound therapy, via inertial cavitation. The control of the inertial cavitation is required to achieve the efficient tissue ablation. Microbubbles between a transducer and a target disturb the ultrasound propagation depending on the conditions. A method to clear such microbubbles has been proposed by Kajiyama et al. [Physics Procedia 3 (2010) 305-314]. In the method, the irradiation of intense ultrasounds with a burst waveform fragmentize microbubbles in the pathways before the irradiation of ultrasounds for tissue heating. The vitro experiment using a gel containing microbubbles has showed that the method enables to heat the target correctly by controlling the microbubble distribution. Following the experiment, we simulate the focusing of ultrasounds through a mixture containing microbubbles with considering the size and number density distributions in space. The numerical simulation shows that the movement of the heating region from the transducer side to the target by controlling the microbubble distributions. The numerical results elucidate well the experimental ones.

  19. Clinical value of real time 3D sonohysterography and 2D sonohysterography in comparison to hysteroscopy with subsequent histopathological examination in perimenopausal women with abnormal uterine bleeding.

    PubMed

    Kowalczyk, Dariusz; Guzikowski, Wojciech; Więcek, Jacek; Sioma-Markowska, Urszula

    2012-01-01

    In many publications the transvaginal ultrasound is regarded as the first step to diagnose the cause of uterine bleeding in perimenopausal women. In order to improve the sensitivity and specificity of the conventional ultrasound physiological saline solution was administered to the uterine cavity and after expansion of its walls the interior uterine cavity was examined. And this procedure is called 2D sonohysterography (SIS 2D). By the ultrasound scanners which enable to get 3D real time image a spatial evaluation of the uterine cavity is possible. Clinical value of the real time 3D sonohysterography and 2D sonohysterography compared to hysteroscopy with histopathological examination in perimenopausal women. The study concerned a group of 97 perimenopausal women with abnormal uterine bleeding. In all of them after a standard transvaginal ultrasonography a catheter was inserted into the uterine cavity. After expansion of the uterine walls by administering about 10 ml of 0,9% saline solution the uterine cavity was examined by conventional sonohysterography. Then a 3D imaging mode was activated and the uterine interior was examined by real time 3D ultrasonography. The ultrasound results were verified by hysteroscopy, the endometrial lesions were removed and underwent a histopathological examination. In two cases the SIS examination was impossible because of uterine cervix atresion. In the rest of examined group the SIS 2D sensitivity and specificity came up to 72 and 96% respectively. In the group of SIS 3D the sensitivity and specificity reached 83 and 99% respectively. Adding SIS 3D, a minimally invasive method, to conventional sonohysterography improves the precision of diagnosis of endometrial pathology, allows to get three-dimensional image of the uterine cavity and enables examination of endometrial lesions. The diagnostic precision of this procedure is similar to the results achieved by hysteroscopy.

  20. A New Era in Diagnostic Ultrasound, Superb Microvascular Imaging: Preliminary Results in Pediatric Hepato-Gastrointestinal Disorders.

    PubMed

    Ohno, Yasuharu; Fujimoto, Tamotsu; Shibata, Yukari

    2017-02-01

    Introduction  Superb microvascular imaging is a new ultrasound image processing technique that uses advanced clutter suppression to extract flow signals from vessels and which helps us visualize very small vascular structures that were not previously visible without the use of a contrast agent. We herein analyzed the usefulness of superb microvascular imaging in the diagnosis of hepato-gastrointestinal disorders in pediatric patients. Materials and Methods  Fifty-six pediatric patients who underwent a total of 81 superb microvascular imaging examinations with an Aplio 300 ultrasound system (Toshiba Medical Systems, Tokyo, Japan) were enrolled in this study. The subjects underwent conventional ultrasound examinations, including Doppler imaging followed by superb microvascular imaging. The superb microvascular imaging findings and standard imaging were compared. All of the examinations were performed without sedation. Results  The average age of the patients (male, n  = 38; female, n  = 18) was 4 years. The clinical diagnoses included hepatobiliary disorders ( n  = 29), acute appendicitis ( n  = 10), and other intestinal disorders ( n  = 17). The target organs for superb microvascular imaging were the liver, appendix, rectum, intestine, gallbladder, and lymph node. In most of the patients, superb microvascular imaging achieved the excellent visualization of microvascular structures, revealing abnormal vasculature in 21 out of 46 (45.7%) examinations of the liver, 9/9 (100%) examinations of the appendix, 0/11 (0%) examinations of the rectum, 9/11 (81.8%) examinations of the intestine, 0/1 (0%) examinations of the gallbladder, and 3/3 (100%) examinations of the lymph nodes. Superb microvascular imaging was superior to Doppler imaging for depicting the microvascular structures. Conclusions  Superb microvascular imaging is especially useful for depicting the microvascular flow and can aid in the diagnosis and treatment planning for pediatric patients with hepato-gastrointestinal disorders. Georg Thieme Verlag KG Stuttgart · New York.

  1. Breast ultrasound tomography with two parallel transducer arrays: preliminary clinical results

    NASA Astrophysics Data System (ADS)

    Huang, Lianjie; Shin, Junseob; Chen, Ting; Lin, Youzuo; Intrator, Miranda; Hanson, Kenneth; Epstein, Katherine; Sandoval, Daniel; Williamson, Michael

    2015-03-01

    Ultrasound tomography has great potential to provide quantitative estimations of physical properties of breast tumors for accurate characterization of breast cancer. We design and manufacture a new synthetic-aperture breast ultrasound tomography system with two parallel transducer arrays. The distance of these two transducer arrays is adjustable for scanning breasts with different sizes. The ultrasound transducer arrays are translated vertically to scan the entire breast slice by slice and acquires ultrasound transmission and reflection data for whole-breast ultrasound imaging and tomographic reconstructions. We use the system to acquire patient data at the University of New Mexico Hospital for clinical studies. We present some preliminary imaging results of in vivo patient ultrasound data. Our preliminary clinical imaging results show promising of our breast ultrasound tomography system with two parallel transducer arrays for breast cancer imaging and characterization.

  2. Integrated phenotypic-genotypic approach to understand the influence of ultrasound on metabolic response of Lactobacillus sakei.

    PubMed

    Ojha, K Shikha; Burgess, Catherine M; Duffy, Geraldine; Kerry, Joseph P; Tiwari, Brijesh K

    2018-01-01

    The lethal effects of soundwaves on a range of microorganisms have been known for almost a century whereas, the use of ultrasound to promote or control their activity is much more recent. Moreover, the fundamental molecular mechanism influencing the behaviour of microorganisms subjected to ultrasonic waves is not well established. In this study, we investigated the influence of ultrasonic frequencies of 20, 45, 130 and 950 kHz on growth kinetics of Lactobacillus sakei. A significant increase in the growth rate of L. sakei was observed following ultrasound treatment at 20 kHz despite the treatment yielding a significant reduction of ca. 3 log cfu/mL in cells count. Scanning electron microscopy showed that ultrasound caused significant changes on the cell surface of L. sakei culture with the formation of pores "sonoporation". Phenotypic microarrays showed that all ultrasound treated L. sakei after exposure to various carbon, nitrogen, phosphorus and sulphur sources had significant variations in nutrient utilisation. Integration of this phenotypic data with the genome of L. sakei revealed that various metabolic pathways were being influenced by the ultrasound treatments. Results presented in this study showed that the physiological response of L. sakei in response to US is frequency dependent and that it can influence metabolic pathways. Hence, ultrasound treatments can be employed to modulate microbial activity for specialised applications.

  3. Integrated phenotypic-genotypic approach to understand the influence of ultrasound on metabolic response of Lactobacillus sakei

    PubMed Central

    Ojha, K. Shikha; Burgess, Catherine M.; Duffy, Geraldine; Kerry, Joseph P.

    2018-01-01

    The lethal effects of soundwaves on a range of microorganisms have been known for almost a century whereas, the use of ultrasound to promote or control their activity is much more recent. Moreover, the fundamental molecular mechanism influencing the behaviour of microorganisms subjected to ultrasonic waves is not well established. In this study, we investigated the influence of ultrasonic frequencies of 20, 45, 130 and 950 kHz on growth kinetics of Lactobacillus sakei. A significant increase in the growth rate of L. sakei was observed following ultrasound treatment at 20 kHz despite the treatment yielding a significant reduction of ca. 3 log cfu/mL in cells count. Scanning electron microscopy showed that ultrasound caused significant changes on the cell surface of L. sakei culture with the formation of pores “sonoporation”. Phenotypic microarrays showed that all ultrasound treated L. sakei after exposure to various carbon, nitrogen, phosphorus and sulphur sources had significant variations in nutrient utilisation. Integration of this phenotypic data with the genome of L. sakei revealed that various metabolic pathways were being influenced by the ultrasound treatments. Results presented in this study showed that the physiological response of L. sakei in response to US is frequency dependent and that it can influence metabolic pathways. Hence, ultrasound treatments can be employed to modulate microbial activity for specialised applications. PMID:29370210

  4. Cranial Ultrasound Lesions in the NICU Predict Cerebral Palsy at Age 2 Years in Children Born at Extremely Low Gestational Age

    PubMed Central

    Kuban, Karl C. K.; Allred, Elizabeth N.; O’Shea, T. Michael; Paneth, Nigel; Pagano, Marcello; Dammann, Olaf; Leviton, Alan; Du Plessis, Adré; Westra, Sjirk J.; Miller, Cindy R.; Bassan, Haim; Krishnamoorthy, Kalpathy; Junewick, Joseph; Olomu, Nicholas; Romano, Elaine; Seibert, Joanna; Engelke, Steve; Karna, Padmani; Batton, Daniel; O’Connor, Sunila E.; Keller, Cecelia E.

    2009-01-01

    Our prospective cohort study of extremely low gestational age newborns evaluated the association of neonatal head ultrasound abnormalities with cerebral palsy at age 2 years. Cranial ultrasounds in 1053 infants were read with respect to intraventricular hemorrhage, ventriculomegaly, and echolucency, by multiple sonologists. Standardized neurological examinations classified cerebral palsy, and functional impairment was assessed. Forty-four percent with ventriculomegaly and 52% with echolucency developed cerebral palsy. Compared with no ultrasound abnormalities, children with echolucency were 24 times more likely to have quadriparesis and 29 times more likely to have hemiparesis. Children with ventriculomegaly were 17 times more likely to have quadriparesis or hemiparesis. Forty-three percent of children with cerebral palsy had normal head ultrasound. Focal white matter damage (echolucency) and diffuse damage (late ventriculomegaly) are associated with a high probability of cerebral palsy, especially quadriparesis. Nearly half the cerebral palsy identified at 2 years is not preceded by a neonatal brain ultrasound abnormality. PMID:19168819

  5. Imaging Feedback of Histotripsy Treatments Using Ultrasound Shear Wave Elastography

    PubMed Central

    Wang, Tzu-Yin; Hall, Timothy L.; Xu, Zhen; Fowlkes, J. Brian; Cain, Charles A.

    2013-01-01

    Histotripsy is a cavitation-based ultrasound therapy that mechanically fractionates soft solid tissues into fluid-like homogenates. This paper investigates the feasibility of imaging the tissue elasticity change during the histotripsy process as a tool to provide feedback for the treatments. The treatments were performed on agar tissue phantoms and ex vivo kidneys using 3-cycle ultrasound pulses delivered by a 750-kHz therapeutic array at peak negative/positive pressure of 17/108 MPa and a repetition rate of 50 Hz. Lesions with different degrees of damage were created with increasing numbers of therapy pulses from 0 to 2000 pulses per treatment location. The elasticity of the lesions was measured with ultrasound shear wave elastography, in which a quasi-planar shear wave was induced by acoustic radiation force generated by the therapeutic array, and tracked with ultrasound imaging at 3000 frames per second. Based on the shear wave velocity calculated from the sequentially captured frames, the Young’s modulus was reconstructed. Results showed that the lesions were more easily identified on the shear wave velocity images than on B-mode images. As the number of therapy pulses increased from 0 to 2000 pulses/location, the Young’s modulus decreased exponentially from 22.1 ± 2.7 to 2.1 ± 1.1 kPa in the tissue phantoms (R2 = 0.99, N = 9 each), and from 33.0 ± 7.1 to 4.0 ± 2.5 kPa in the ex vivo kidneys (R2 = 0.99, N = 8 each). Correspondingly, the tissues transformed from completely intact to completely fractionated as examined via histology. A good correlation existed between the lesions’ Young’s modulus and the degree of tissue fractionation as examined with the percentage of remaining structurally intact cell nuclei (R2 = 0.91, N = 8 each). These results indicate that lesions produced by histotripsy can be detected with high sensitivity using shear wave elastography. Because the decrease in the tissue elasticity corresponded well with the morphological and histological change, this study provides a basis for predicting the local treatment outcomes from tissue elasticity change. PMID:22711412

  6. Imaging feedback of histotripsy treatments using ultrasound shear wave elastography.

    PubMed

    Wang, Tzu-Yin; Hall, Timothy L; Xu, Zhen; Fowlkes, J Brian; Cain, Charles A

    2012-06-01

    Histotripsy is a cavitation-based ultrasound therapy that mechanically fractionates soft solid tissues into fluid-like homogenates. This paper investigates the feasibility of imaging the tissue elasticity change during the histotripsy process as a tool to provide feedback for the treatments. The treatments were performed on agar tissue phantoms and ex vivo kidneys using 3-cycle ultrasound pulses delivered by a 750-kHz therapeutic array at peak negative/positive pressure of 17/108 MPa and a repetition rate of 50 Hz. Lesions with different degrees of damage were created with increasing numbers of therapy pulses from 0 to 2000 pulses per treatment location. The elasticity of the lesions was measured with ultrasound shear wave elastography, in which a quasi-planar shear wave was induced by acoustic radiation force generated by the therapeutic array, and tracked with ultrasound imaging at 3000 frames per second. Based on the shear wave velocity calculated from the sequentially captured frames, the Young's modulus was reconstructed. Results showed that the lesions were more easily identified on the shear wave velocity images than on B-mode images. As the number of therapy pulses increased from 0 to 2000 pulses/location, the Young's modulus decreased exponentially from 22.1 ± 2.7 to 2.1 ± 1.1 kPa in the tissue phantoms (R2 = 0.99, N = 9 each), and from 33.0 ± 7.1 to 4.0 ± 2.5 kPa in the ex vivo kidneys (R2 = 0.99, N = 8 each). Correspondingly, the tissues transformed from completely intact to completely fractionated as examined via histology. A good correlation existed between the lesions' Young's modulus and the degree of tissue fractionation as examined with the percentage of remaining structurally intact cell nuclei (R2 = 0.91, N = 8 each). These results indicate that lesions produced by histotripsy can be detected with high sensitivity using shear wave elastography. Because the decrease in the tissue elasticity corresponded well with the morphological and histological change, this study provides a basis for predicting the local treatment outcomes from tissue elasticity change.

  7. Impact of ultrasound video transfer on the practice of ultrasound

    NASA Astrophysics Data System (ADS)

    Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh

    1996-05-01

    Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.

  8. Ultrasound biomicroscopy after canaloplasty: clinical study with two different units.

    PubMed

    Doro, Daniele; Koerber, Norbert; Paolucci, Pierpaolo; Cimatti, Pierangela

    2012-12-01

    Canaloplasty is a recent non penetrating glaucoma surgical procedure where Schlemm's canal is dilated and trabecular meshwork distended by tensioning polypropylene suture. The aim of this study was to visualize the iridocorneal angle after the canaloplasty procedure by means of two different ultrasound biomicroscopy (UBM) units. Ten eyes of nine patients with primary open angle glaucoma (average age 62 years) underwent canaloplasty (six eyes) or canaloplasty combined with phacoemulsification and in-the-bag intraocular lens implantation (4 eyes). Both 50 MHz (Paradigm P45) and 80 MHz (i-UltraSound) systems were used. All procedures were performed by the same surgeon. UBM examination was performed 3 to 12 (mean 7 +/- 3.1) months after surgery. No, mild and good trabecular meshwork distension by suture tensioning was graded as 0, 1 and 2 according to the higher resolution 80 MHz images. Both ultrasound systems could show intrascleral lake and trabecular meshwork distension, which was graded as 0, 1 and 2 in 10%, 30% and 60% of eyes, respectively. Schlemm's canal could be imaged with the 80 MHz transducer only. The overall qualified success of canaloplasty (80%) was apparently correlated with suture tensioning (r=0.64). In our experience, after canaloplasty the 80 MHz but also 50 MHz technology can show trabecular meshwork distension. A greater number of eyes are needed to assess the correlation between intraocular pressure decrease and suture tensioning.

  9. [Phenotype of patients with gynecomastia].

    PubMed

    Czajka-Oraniec, Izabella; Zgliczyński, Wojciech

    2008-01-01

    Gynecomastia, a benign enlargement of the breast glandular tissue in men. The aim of the study was to evaluate the phenotype of patients with gynecomastia, in particular antropometric assessment, breast ultrasound examination and hormonal testing, as well as to estimate possible causes of gynecomastia in studied population. Two hundred-twenty men were enrolled in the study: 126 patients with gynecomastia and 94 healthy volunteers as a control group. Detailed medical examination, breast ultrasound and hormonal assays for T, E2, LH, FSH, SHBG, S-DHEA, PRL and TSH were performed. Calculation of free testosterone concentration was done. The results of clinical and hormonal evaluation enabled to divide the cases into three groups: patients with idiopathic gynecomastia (58 subjects, 46%), with hypogonadism (34 subjects, 27%) and drug-induced or associated with other disorders gynecomastia (34 subjects, 27%). We found that men with gynecomastia, particularly associated with hypogonadism, had significantly higher BMI compared with control group. Ultrasound examination revealed the positive correlation between breast tissue volume and BMI, duration of gynecomastia and estradiol level, while negative correlation with testosterone level. We demonstrated significant differences in LH, T, SHBG, fT and S-DHEA levels between cases and controls. There were no differences in PRL, FSH and TSH levels among groups. Significant elevation of SHBG concentration in all groups of patients, including idiopathic gynecomastia cases, compared with controls, was remarkable. Clinical evaluation and hormonal profile can help to classify patient with gynecomastia into one of three groups: idiopathic gynecomastia, associated with hypogonadism, and drug-induced or associated with other diseases. Idiopathic gynecomastia - of unknown etiology is diagnosed in almost half of all cases (46%). We showed that apart from well known hormonal disturbances leading to gynecomastia, like hypogonadism or hyperestrogenism, also subtle hormonal alterations, such as sex hormone binding globuline (SHBG) level elevation may contribute to breast enlargement.

  10. [Discussion on relationship between hepatobiliary pathological changes under B-ultrasound and Clonorchis sinensis infection].

    PubMed

    Liang, Zhi-cheng; Qiu, Shou-zhong; Luo, Li-xuan

    2015-12-01

    To explore the relationship between the hepatobiliary pathological changes under B-ultrasound examinations and Clonorchis sinensis infection, so as to provide the evidence for further prevention and control. The stool test and ELISA were applied to test the pathogeny and antibody to C. sinensis of the suspicious patients who had the hepatobiliary pathological changes under B-ultrasound examinations in People's Hospital of Wuxuan County from Jan. 2010 to Dec. 2013. Totally 113 suspicious patients of C. sinensis infection were investigated, and the positive rates of egg and serum antibody were 64.60% (73 cases) and 66.37% (75 cases) respectively. The positive rates of the male and those aged ≥ 50 years were significantly higher than those of the female and the cases younger than 50 years respectively (χ² = 3.554, 6.267, both P < 0.05). In the C. sinensis infected patients, the degree of pathological changes of hepatobiliary was positively correlated with the infectiosity of C. sinensis (χ² = 64.952, P < 0.01). The hepatobiliary pathological changes under B-ultrasound examinations may be resulted from the infection of C. sinensis, and the patients with the changes should be further investigated for the pathogen and antibody to C. sinensis.

  11. [Correction of respiratory movement using ultrasound for cardiac nuclear medicine examinations: fundamental study using an X-ray TV machine].

    PubMed

    Yoda, Kazushige; Umeda, Tokuo; Hasegawa, Tomoyuki

    2003-11-01

    Organ movements that occur naturally as a result of vital functions such as respiration and heartbeat cause deterioration of image quality in nuclear medicine imaging. Among these movements, respiration has a large effect, but there has been no practical method of correcting for this. In the present study, we examined a method of correction that uses ultrasound images to correct baseline shifts caused by respiration in cardiac nuclear medicine examinations. To evaluate the validity of this method, simulation studies were conducted with an X-ray TV machine instead of a nuclear medicine scanner. The X-ray TV images and ultrasound images were recorded as digital movies and processed with public domain software (Scion Image). Organ movements were detected in the ultrasound images of the subcostal four-chamber view mode using slit regions of interest and were measured on a two-dimensional image coordinate. Then translational shifts were applied to the X-ray TV images to correct these movements by using macro-functions of the software. As a result, respiratory movements of about 20.1 mm were successfully reduced to less than 2.6 mm. We conclude that this correction technique is potentially useful in nuclear medicine cardiology.

  12. Incidental detection of ascariasis worms on USG in a protein energy malnourished (PEM) child with abdominal pain.

    PubMed

    Suthar, Pokhraj Prakashchandra; Doshi, Rajkumar Prakashbhai; Mehta, Chetan; Vadera, Khyati P

    2015-03-12

    A 10-year-old child presented with dull aching periumbilical abdominal pain for 15 days. The child was not gaining weight despite a good appetite. Physical examination of the child revealed grade-I protein energy malnourishment (PEM) according to IAP (Indian Academic of Paediatrics) classification. The rest of the systemic examination was normal. Routine blood investigation revealed anaemia with eosinophilia. Abdominal ultrasonography did not show any abnormality with curvilinear transducer (3.5-5 MHz), however, linear ultrasound transducer (7.5-12 MHz) with harmonic tissue imaging showed worms in the lumen of the small intestine with curling movement on real time scanning. Stool examination for the eggs of ascariasis was positive. The patient was treated with antihelminthic drugs. Dietary modification for the PEM was advised. After 3 months of treatment, the patient improved and stool examination for Ascaris was negative on follow-up. 2015 BMJ Publishing Group Ltd.

  13. Lung ultrasound accurately detects pneumothorax in a preterm newborn lamb model.

    PubMed

    Blank, Douglas A; Hooper, Stuart B; Binder-Heschl, Corinna; Kluckow, Martin; Gill, Andrew W; LaRosa, Domenic A; Inocencio, Ishmael M; Moxham, Alison; Rodgers, Karyn; Zahra, Valerie A; Davis, Peter G; Polglase, Graeme R

    2016-06-01

    Pneumothorax is a common emergency affecting extremely preterm. In adult studies, lung ultrasound has performed better than chest x-ray in the diagnosis of pneumothorax. The purpose of this study was to determine the efficacy of lung ultrasound (LUS) examination to detect pneumothorax using a preterm animal model. This was a prospective, observational study using newborn Border-Leicester lambs at gestational age = 126 days (equivalent to gestational age = 26 weeks in humans) receiving mechanical ventilation from birth to 2 h of life. At the conclusion of the experiment, LUS was performed, the lambs were then euthanised and a post-mortem exam was immediately performed. We used previously published ultrasound techniques to identify pneumothorax. Test characteristics of LUS to detect pneumothorax were calculated, using the post-mortem exam as the 'gold standard' test. Nine lambs (18 lungs) were examined. Four lambs had a unilateral pneumothorax, all of which were identified by LUS with no false positives. This was the first study to use post-mortem findings to test the efficacy of LUS to detect pneumothorax in a newborn animal model. Lung ultrasound accurately detected pneumothorax, verified by post-mortem exam, in premature, newborn lambs. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  14. Register cardiac fiber orientations from 3D DTI volume to 2D ultrasound image of rat hearts

    NASA Astrophysics Data System (ADS)

    Qin, Xulei; Wang, Silun; Shen, Ming; Zhang, Xiaodong; Lerakis, Stamatios; Wagner, Mary B.; Fei, Baowei

    2015-03-01

    Two-dimensional (2D) ultrasound or echocardiography is one of the most widely used examinations for the diagnosis of cardiac diseases. However, it only supplies the geometric and structural information of the myocardium. In order to supply more detailed microstructure information of the myocardium, this paper proposes a registration method to map cardiac fiber orientations from three-dimensional (3D) magnetic resonance diffusion tensor imaging (MR-DTI) volume to the 2D ultrasound image. It utilizes a 2D/3D intensity based registration procedure including rigid, log-demons, and affine transformations to search the best similar slice from the template volume. After registration, the cardiac fiber orientations are mapped to the 2D ultrasound image via fiber relocations and reorientations. This method was validated by six images of rat hearts ex vivo. The evaluation results indicated that the final Dice similarity coefficient (DSC) achieved more than 90% after geometric registrations; and the inclination angle errors (IAE) between the mapped fiber orientations and the gold standards were less than 15 degree. This method may provide a practical tool for cardiologists to examine cardiac fiber orientations on ultrasound images and have the potential to supply additional information for diagnosis of cardiac diseases.

  15. Might telesonography be a new useful diagnostic tool aboard merchant ships? A pilot study.

    PubMed

    Nikolić, Nebojsa; Mozetić, Vladimir; Modrcin, Bob; Jaksić, Slaven

    2006-01-01

    Developments of new, ultra-light diagnostic ultrasound systems (UTS) and modern satellite telecommunication networks are opening new potential applications for diagnostic sonography. One such area is maritime medicine. It is our belief that ship officers can be trained to use diagnostic ultrasound systems with the aim to generate ultrasound images of sufficient quality to be interpreted by medical professionals qualified to read sonograms. To test our thesis we included lectures and hands on scanning practice to the current maritime medicine curriculum at the Faculty of Maritime Studies at the University of Rijeka. Following the didactic and practical training all participating students examined several patients, some with pathology some without. Images obtained by students were then submitted for interpretation to a qualified physician (specialist of general surgery trained in UTS) who was unaware of the patient's pathology. In total, 37 students performed 37 examinations and made 45 ultrasound images, on 3 patients. In this paper, results on this pilot study are presented. It is possible to teach ship officers to produce diagnostically usable ultrasound pictures aboard ships at sea. But before reaching final conclusion about applicability of telesonography on board merchant ships, further studies are necessary, that would include studies of economic feasibility, and on validity of introducing such a diagnostic tool to the maritime medical practice.

  16. Contrast-enhanced ultrasound in portal venous system aneurysms: a multi-center study.

    PubMed

    Tana, Claudio; Dietrich, Christoph F; Badea, Radu; Chiorean, Liliana; Carrieri, Vincenzo; Schiavone, Cosima

    2014-12-28

    To investigate contrast-enhanced ultrasound (CEUS) findings in portal venous system aneurysms (PVSAs). In this multi-center, retrospective, case series study, we evaluated CEUS features of seven cases of PVSAs that were found incidentally on conventional ultrasound in the period 2007-2013. Three Ultrasound Centers were involved (Chieti, Italy, Bad Mergentheim, Germany, and Cluj-Napoca, Romania). All patients underwent CEUS with Sonovue(®) (Bracco, Milan, Italy) at a standard dose of 2.4 mL, followed by 10 mL of 0.9% saline solution. The examinations were performed using multifrequency transducers and low mechanical index. We considered aneurysmal a focal dilatation of the portal venous system with a size that was significantly greater than the remaining segments of the same vein, and that was equal or larger than 21 mm for the extrahepatic segments of portal venous system, main portal vein and bifurcation, and 9 mm for the intrahepatic branches. After contrast agent injection, all PVSAs were not enhanced in the arterial phase (starting 8-22 s). All PVSAs were then rapidly enhanced in the early portal venous phase (starting three to five seconds after the arterial phase, 11-30 s), with persistence and slow washout of the contrast agent in the late phase (starting 120 s). In all patients, CEUS confirmed the presence of a "to-and-fro" flow by showing a swirling pattern within the dilatation in the early portal venous phase. CEUS also improved the delineation of the lumen, and was reliable in showing its patency degree and integrity of walls. In one patient, CEUS showed a partial enhancement of the lumen with a uniformly nonenhancing area in the portal venous and late phases, suggesting thrombosis. In our case series, we found that CEUS could be useful in the assessment and follow-up of a PVSA. Further studies are needed to validate its diagnostic accuracy.

  17. Disruption of Prostate Microvasculature by Combining Microbubble-Enhanced Ultrasound and Prothrombin

    PubMed Central

    Liu, Yongliang; Qiao, Lu; Gao, Wenhong; Zhang, Weiguo; Liu, Zheng

    2016-01-01

    Previous studies have shown a unique method to disrupt tumor vasculature using pulsed, high-pressure amplitude therapeutic ultrasound combined with microbubbles. In this study, we attempted to destroy the prostate vasculature of canine prostates using microbubble-enhanced ultrasound (MEUS) and prothrombin. The prostates of 43 male mongrel canines were surgically exposed. Twenty-two prostates were treated using MEUS (n = 11) or MEUS and prothrombin (PMEUS, n = 11). The other 21 prostates, which were treated using microbubbles (n = 7), ultrasound (n = 7) or prothrombin (n = 7) only, served as the controls. Prothrombin was intravenously infused at 20 IU/kg. MEUS was induced using a therapeutic ultrasound device at a peak negative pressure of 4.47 MPa and a microbubble injection. Contrast-enhanced ultrasound was performed to assess the blood perfusion of the prostates. Then, the prostate tissue was harvested immediately after treatment and at 48 hours later for pathological examination. The contrast-enhanced ultrasound peak value of the prostate decreased significantly from 36.2 ± 5.6 to 27.1 ± 6.3 after treatment in the PMEUS group, but it remained unchanged in the other groups. Histological examination found severe microvascular rupture, hemorrhage and thrombosis in both MEUS- and PMEUS-treated prostates immediately after treatment, while disruption in the PMEUS group was more severe than in the MEUS group. Forty-eight hours after treatment, massive necrosis and infiltration of white blood cells occurred in the PMEUS group. This study demonstrated that PMEUS disrupted the normal microvasculature of canine prostates and induced massive necrosis. PMEUS could potentially become a new noninvasive method used for the treatment of benign prostatic hyperplasia. PMID:27643992

  18. Ultrasound for internal medicine physicians: the future of the physical examination.

    PubMed

    Dulohery, Megan M; Stoven, Samantha; Kurklinsky, Andrew K; Kurklinksy, Andrew; Halvorsen, Andrew; McDonald, Furman S; Bhagra, Anjali

    2014-06-01

    With the advent of compact ultrasound (US) devices, it is easier for physicians to enhance their physical examinations through the use of US. However, although this new tool is widely available, few internal medicine physicians have US training. This study sought to understand physicians' baseline knowledge and skill, provide education in US principles, and demonstrate that proper use of compact US devices is a skill that can be quickly learned. Training was performed at the Mayo Clinic in June 2010 and June 2011. The participants consisted of internal medicine residents. The workshop included didactics and hands-on US experiences with human and cadaver models in a simulation center. Pretests and posttests of residents' knowledge, attitudes, and skills with US were completed. We reassessed the 2010 group in the spring of 2012 with a long-term retention survey for knowledge and confidence in viewing images. A total of 136 interns completed the workshop. Thirty-nine residents completed the long-term retention survey. Posttest assessments showed a statistically significant improvement in the knowledge of US imaging, confidence in identifying structures, image identification, and image acquisition (P < .0001). In the long-term retention study, knowledge of US imaging and confidence in identifying structures did decline. This educational intervention resulted in improvement in US knowledge and image acquisition. However, the knowledge diminished over time, suggesting that further education is needed if US is to become an important component of internal medicine training and practice. © 2014 by the American Institute of Ultrasound in Medicine.

  19. Incremental value of pocket-sized imaging device for bedside diagnosis of unilateral pleural effusions and ultrasound-guided thoracentesis

    PubMed Central

    Lisi, Matteo; Cameli, Matteo; Mondillo, Sergio; Luzzi, Luca; Zacà, Valerio; Cameli, Paolo; Gotti, Giuseppe; Galderisi, Maurizio

    2012-01-01

    OBJECTIVES The present study aimed to assess the additional value of a pocket-sized imaging device (PSID) as an adjunct to plain chest X-rays in the diagnosis of pleural effusion (PE), mainly for those requiring pleural thoracentesis. METHODS We performed a thoracic ultrasound examination using a PSID in 73 patients with an abnormal chest X-ray diagnostic for unilateral PE. Abundant PE was defined as an interpleural distance between the diaphragm and visceral pleura (VP) of ≥30 mm at the apex of the 50 mm bisector line of the costodiaphragmatic recess at end expiration. RESULTS According to PSID ultrasound evaluation, abundant PE was present in 46 patients (63%), while 27 (37%) patients showed the presence of mild PE or absence of PE. Thoracentesis was performed successfully and without procedure-induced complications in all 46 patients with abundant PE. Using the above-mentioned method, we obtained a high diagnostic accuracy (area under the curve = 0.99) and excellent sensitivity and specificity of 91.7 and 99.9%, respectively, to predict a PE >1000 ml, when VP was >6.3 cm. CONCLUSIONS PSID is a useful tool that may integrate and complete the physical examination, also providing additional information to chest X-ray in the clinical management of patients with suspected PE. PSID evaluation can also increase the effectiveness and safety of thoracentesis. PMID:22815326

  20. Point-of-care ultrasound performed by a medical student compared to physical examination by vascular surgeons in the detection of abdominal aortic aneurysms.

    PubMed

    Mai, Trinh; Woo, Michael Y; Boles, Kim; Jetty, Prasad

    2018-05-16

    To determine the test characteristics of point-of-care ultrasonography performed by a medical student versus physical examination by vascular surgeons compared to a gold standard reference scan for the detection of abdominal aortic aneurysms. We conducted a prospective, observer-blinded study recruiting patients from an outpatient vascular surgery clinic. Participants were screened for abdominal aortic aneurysms by standardized physical examination by a blinded vascular surgeon, followed by a point-of-care ultrasound examination by a blinded medical student. The student underwent prior training by a vascular sonographer and emergency physician on 60 patients (16 were supervised). Ultrasonography was used to visualize and measure the proximal, mid, and distal aortic diameters. The maximal aortic diameter was noted and compared to measurements obtained by the reference scan (CT scan or vascular sonographer-performed ultrasound). Reference scans were completed within 3 months of the recruitment visit. A total of 57 patients were enrolled over a 5-month period between October 2015 and March 2016. Mean age of recruited patients was 71 years and 61% were male. Mean body mass index was 27.9 ± 4.3 and mean waist-hip ratio was 0.96 ± 0.10. Sixteen abdominal aortic aneurysms were detected by the reference scan, with an average maximal aortic diameter of 44.9 mm. Physical examination by a vascular surgeon detected 11 of 16 abdominal aortic aneurysms with 2 false positives (sensitivity and specificity of 66.7% (95% CI 38.4-88.2) and 94.4% (95% CI 81.3-99.3), respectively). Point-of-care ultrasound detected 15 of 16 abdominal aortic aneurysms (sensitivity and specificity of 93.3% (95% CI 68.1-99.8) and 100% (95% CI 88.4-100), respectively). Seven of the 64 point-of-care ultrasound scans were indeterminate (>1 cm of the aorta was not visualized). Average time to conduct the physical examination was 35 seconds vs. 4.0 minutes for point-of-care ultrasonography. There was a strong linear correlation (R2=0.95) between maximal aortic diameter measured by point-of-care ultrasonography vs referencescan with a mean absolute difference of 2.6 mm. Point-of-care ultrasonography performed by a medical student is highly accurate and more effective in detecting abdominal aortic aneurysms when compared to physical examination by vascular surgeons. The introduction of point-of-care ultrasound training at the medical student level, and its wide-scale implementation as an extension to physical examination, may lead to improved detection of abdominal aortic aneurysms. Copyright © 2018. Published by Elsevier Inc.

Top