Sample records for ultrasound fine needle

  1. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  2. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  3. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    PubMed Central

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  4. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    PubMed Central

    Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre

    2011-01-01

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer. PMID:24212643

  5. Validation of a technique for accurate fine-wire electrode placement into posterior gluteus medius using real-time ultrasound guidance.

    PubMed

    Hodges, P W; Kippers, V; Richardson, C A

    1997-01-01

    Fine-wire electromyography is primarily utilised for the recording of activity of the deep musculature, however, due to the location of these muscles, accurate electrode placement is difficult. Real-time ultrasound imaging (RTUI) of muscle tissue has been used for the guidance of the needle insertion for the placement of electrodes into the muscles of the abdominal wall. The validity of RTUI guidance of needle insertion into the deep muscles has not been determined. A cadaveric study was conducted to evaluate the accuracy with which RTUI can be used to guide fine-wire electrode placement using the posterior fibres of gluteus medius (PGM) as an example. Pilot studies revealed that the ultrasound resolution of cadaveric tissue is markedly reduced making it impossible to directly evaluate the technique, therefore, three studies were conducted. An initial study involved the demarcation of the anatomical boundaries of PGM using RTUI to define a technique based on an anatomical landmark that was consisent with the in vivo RTUI guided needle placement technique. This anatomical landmark was then used as the guide for the cadaveric needle insertion. Once the needle was positioned 0.05 ml of dye was introduced and the specimen dissected. The dye was accurately placed in PGM in 100% of the specimens. Finally, fine-wire electrodes were inserted into the PGM of five volunteers and manoeuvres performed indicating the accuracy of placement. This study supports the use of ultrasound imaging for the accurate guidance of needle insertion for fine-wire and needle EMG electrodes.

  6. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  7. Endoscopic ultrasound-guided fine-needle aspiration needles: which one and in what situation?

    PubMed

    Karadsheh, Zeid; Al-Haddad, Mohammad

    2014-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is increasingly used as a diagnostic and therapeutic tool for pancreatic and other gastrointestinal disorders. Several factors affect the outcome of EUS-FNA, one of which is needle size. The decision to use a specific needle depends on factors including location, consistency, and type of the lesion; presence of onsite cytopathologist; and need for additional tissue procurement for histology. This review provides a balanced perspective on the use of different needle sizes available, highlighting the differences among them and potential niche applications of each to maximize diagnostic yield of EUS-FNA. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Ultrasonography and fine needle aspirate cytology of the mesenteric lymph node in normal domestic ferrets (Mustela putorius furo).

    PubMed

    Paul-Murphy, J; O'Brien, R T; Spaeth, A; Sullivan, L; Dubielzig, R R

    1999-01-01

    The large mesenteric lymph node of 28 normal ferrets was imaged with ultrasound. The large node, located in the mid-abdomen at the root of the mesentery, was round to ovoid and uniformly hyperechoic. Mean ultrasonographic dimensions of the lymph node were 12.6 +/- 2.6 mm by 7.6 +/- 2.0 mm. Fine needle aspirates of 20 lymph nodes were obtained either using ultrasound guided free-hand techniques or at necropsy. The cytological descriptions were compared to histological descriptions of 13 lymph node core biopsies obtained during laparotomy or necropsy as well as 10 peripheral blood smear differentials. The large mesenteric lymph node of ferrets could be easily imaged and measured by ultrasound and evaluated by fine needle aspirate cytology. Normal lymph node cytology may include an eosinophilic infiltrate.

  9. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases.

    PubMed

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-12-14

    To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients ( P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group ( P < 0.05). Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration.

  11. Two Cases of Lethal Complications Following Ultrasound-Guided Percutaneous Fine-Needle Biopsy of the Liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drinkovic, Ivan; Brkljacic, Boris

    1996-09-15

    Two cases with lethal complications are reported among 1750 ultrasound (US)-guided percutaneous fine-needle liver biopsies performed in our department. The first patient had angiosarcoma of the liver which was not suspected after computed tomography (CT) and US studies had been performed. The other patient had hepatocellular carcinoma in advanced hepatic cirrhosis. Death was due to bleeding in both cases. Pre-procedure laboratory tests did not reveal the existence of major bleeding disorders in either case. Normal liver tissue was interposed in the needle track between the liver capsule and the lesions which were targeted.

  12. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses

    PubMed Central

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-01-01

    Objective: Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. Patients and Methods: A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). Results: EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). Conclusion: EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate. PMID:24949394

  13. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  14. The diagnostic value of thyroglobulin concentration in fine-needle aspiration of the cervical lymph nodes in patients with differentiated thyroid cancer.

    PubMed

    Mikosiński, Sławomir; Pomorski, Lech; Oszukowska, Lidia; Makarewicz, Jacek; Adamczewski, Zbigniew; Sporny, Stanisław; Lewiński, Andrzej

    2006-01-01

    Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and (131)I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15-711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94-100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes in patients with differentiated thyroid cancer.

  15. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases

    PubMed Central

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-01-01

    AIM To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. METHODS Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. RESULTS There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients (P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group (P < 0.05). CONCLUSION Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration. PMID:28028373

  16. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    PubMed

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  17. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  18. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  19. Isolated splenic tuberculosis diagnosed by endoscopic ultrasound-guided fine needle aspiration.

    PubMed

    Nasa, Mukesh; Choudhary, Narendra S; Guleria, Mridula; Puri, Rajesh

    2017-04-01

    Our patient was a 48-year-old female, who presented with history of persistent low-grade fever and weight loss. The CT scan of the abdomen revealed multiple hypodense lesions in spleen. No primary focus of infection was detected in any other organs. Endoscopic ultrasound-guided fine needle aspiration of splenic lesion revealed granulomatous inflammation. The patient was started on anti-tuberculous therapy. There is a diagnostic possibility of splenic tuberculosis even in immunocompetent individuals and we chose a combination anti-tuberculous therapy as the first line treatment with consideration of splenectomy depending on the response. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  20. Detecting and Treating Thyroid Nodules and Cancer Before, During, and After Pregnancy

    MedlinePlus

    ... nodules relies mainly on the results of thyroid ultrasound imaging and fine-needle aspiration biopsy . A biopsy is the removal of a small sample of the nodule for further testing. Thyroid ultrasound uses the same safe technique of high- frequency ...

  1. Regional lymph node staging in breast cancer: the increasing role of imaging and ultrasound-guided axillary lymph node fine needle aspiration.

    PubMed

    Mainiero, Martha B

    2010-09-01

    The status of axillary lymph nodes is a key prognostic indicator in patients with breast cancer and helps guide patient management. Sentinel lymph node biopsy is increasingly being used as a less morbid alternative to axillary lymph node dissection. However, when sentinel lymph node biopsy is positive, axillary dissection is typically performed for complete staging and local control. Axillary ultrasound and ultrasound-guided fine needle aspiration (USFNA) are useful for detecting axillary nodal metastasis preoperatively and can spare patients sentinel node biopsy, because those with positive cytology on USFNA can proceed directly to axillary dissection or neoadjuvant chemotherapy. Internal mammary nodes are not routinely evaluated, but when the appearance of these nodes is abnormal on imaging, further treatment or metastatic evaluation may be necessary. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. Convolution neural networks for real-time needle detection and localization in 2D ultrasound.

    PubMed

    Mwikirize, Cosmas; Nosher, John L; Hacihaliloglu, Ilker

    2018-05-01

    We propose a framework for automatic and accurate detection of steeply inserted needles in 2D ultrasound data using convolution neural networks. We demonstrate its application in needle trajectory estimation and tip localization. Our approach consists of a unified network, comprising a fully convolutional network (FCN) and a fast region-based convolutional neural network (R-CNN). The FCN proposes candidate regions, which are then fed to a fast R-CNN for finer needle detection. We leverage a transfer learning paradigm, where the network weights are initialized by training with non-medical images, and fine-tuned with ex vivo ultrasound scans collected during insertion of a 17G epidural needle into freshly excised porcine and bovine tissue at depth settings up to 9 cm and [Formula: see text]-[Formula: see text] insertion angles. Needle detection results are used to accurately estimate needle trajectory from intensity invariant needle features and perform needle tip localization from an intensity search along the needle trajectory. Our needle detection model was trained and validated on 2500 ex vivo ultrasound scans. The detection system has a frame rate of 25 fps on a GPU and achieves 99.6% precision, 99.78% recall rate and an [Formula: see text] score of 0.99. Validation for needle localization was performed on 400 scans collected using a different imaging platform, over a bovine/porcine lumbosacral spine phantom. Shaft localization error of [Formula: see text], tip localization error of [Formula: see text] mm, and a total processing time of 0.58 s were achieved. The proposed method is fully automatic and provides robust needle localization results in challenging scanning conditions. The accurate and robust results coupled with real-time detection and sub-second total processing make the proposed method promising in applications for needle detection and localization during challenging minimally invasive ultrasound-guided procedures.

  3. The cost-effectiveness of iodine 131 scintigraphy, ultrasonography, and fine-needle aspiration biopsy in the initial diagnosis of solitary thyroid nodules.

    PubMed

    Khalid, Ayesha N; Hollenbeak, Christopher S; Quraishi, Sadeq A; Fan, Chris Y; Stack, Brendan C

    2006-03-01

    To compare the cost-effectiveness of fine-needle aspiration biopsy, iodine 131 scintigraphy, and ultrasonography for the initial diagnostic workup of a solitary palpable thyroid nodule. A deterministic cost-effectiveness analysis was conducted using a decision tree to model the diagnostic strategies. A single, mid-Atlantic academic medical center. Expected costs, expected number of cases correctly diagnosed, and incremental cost per additional case correctly diagnosed. Relative to the routine use of fine-needle aspiration biopsy, the incremental cost per case correctly diagnosed is 24,554 dollars for the iodine 131 scintigraphy strategy and 1212 dollars for the ultrasound strategy. A diagnostic strategy using initial fine-needle aspiration biopsy for palpable thyroid nodules was found to be cost-effective compared with the other approaches as long as a payor's willingness to pay for an additional correct diagnosis is less than 1212 dollars. Prospective studies are needed to validate these finding in clinical practice.

  4. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    PubMed

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  5. Endoscopic Ultrasound (EUS) Guided Fine Needle Aspiration: A New Modality to Diagnose Peritoneal Tuberculosis in Presence of Decompensated Cirrhosis-A Case Series and Review of Literature.

    PubMed

    Daswani, Ravi; Kumar, Ashish; Singla, Vikas; Kaur, Gagandeep; Sharma, Praveen; Bansal, Naresh; Arora, Anil

    2018-06-01

    The gold-standard for diagnosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the non-specific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal TB. To assess the role of EUS-FNA in the diagnosis of peritoneal tuberculosis in patients with decompensated cirrhosis. Consecutive patients with peritoneal thickening, ascites and decompensated cirrhosis underwent EUS-FNA from the thickened omentum. Presence of granuloma or demonstration of acid fast bacilli was diagnostic of peritoneal tuberculosis. A total of 5 patients with CLD underwent EUS-FNA from omentum. FNA cytology revealed granuloma with multinucleated cells in all patients (100%) and AFB stain was positive in 2 of them (40%). We hereby report the use of EUS guided fine needle aspiration (FNA) of peritoneum as a newer, safe and unexplored technique for diagnosis of peritoneal TB.

  6. Endobronchial ultrasound-guided transbronchial needle aspiration of thyroid: Report of two cases and systematic review of literature

    PubMed Central

    Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep

    2016-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005

  7. Cell-block procedure in endoscopic ultrasound-guided-fine-needle-aspiration of gastrointestinal solid neoplastic lesions

    PubMed Central

    Ieni, Antonio; Barresi, Valeria; Todaro, Paolo; Caruso, Rosario Alberto; Tuccari, Giovanni

    2015-01-01

    In the present review we have analyzed the clinical applications of endoscopic ultrasound-guided-fine-needle-aspiration (EUS-FNA) and the methodological aspects obtained by cell-block procedure (CBP) in the diagnostic approach to the gastrointestinal neoplastic pathology. CBP showed numerous advantages in comparison to the cytologic routine smears; in particular, better preservation of cell architecture, achievement of routine haematoxylin-eosin staining equivalent to histological slides and possibility to perform immunohistochemistry or molecular analyses represented the most evident reasons to choose this method. Moreover, by this approach, the differential diagnosis of solid gastrointestinal neoplasias may be more easily achieved and the background of contaminant non-neoplastic gastrointestinal avoided. Finally, biological samples collected by EUS-FNA CBP-assisted should be investigated in order to identify and quantify further potential molecular markers. PMID:26322154

  8. Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses

    PubMed Central

    Voss, M; Hammel, P; Molas, G; Palazzo, L; Dancour, A; O'Toole, D; Terris, B; Degott, C; Bernades, P; Ruszniewski, P

    2000-01-01

    AIM—To assess the feasibility and diagnostic accuracy of endoscopic ultrasound guided fine needle biopsy (EUS-FNAB) in patients with solid pancreatic masses.
METHODS—Ninety nine consecutive patients with pancreatic masses were studied. Histological findings obtained by EUS-FNAB were compared with the final diagnosis assessed by surgery, biopsy of other tumour site or at postmortem examination, or by using a combination of clinical course, imaging features, and tumour markers.
RESULTS—EUS-FNAB was feasible in 90 patients (adenocarcinomas, n = 59; neuroendocrine tumours, n = 15; various neoplasms, n = 6; pancreatitis, n = 10), and analysable material was obtained in 73. Tumour size (⩾ or < 25 mm in diameter) did not influence the ability to obtain informative biopsy samples. Diagnostic accuracy was 74.4% (adenocarcinomas, 81.4%; neuroendocrine tumours, 46.7%; other lesions, 75%; p<0.02). Overall, the diagnostic yield in all 99 patients was 68%. Successful biopsies were performed in six patients with portal hypertension. Minor complications (moderate bleeding or pain) occurred in 5% of cases.
CONCLUSIONS—EUS-FNAB is a useful and safe method for the investigation of pancreatic masses, with a high feasibility rate even when lesions are small. Overall diagnostic accuracy of EUS-FNAB seems to depend on the tumour type.


Keywords: pancreas; tumour; endoscopic ultrasound; fine needle aspiration biopsy PMID:10644320

  9. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    PubMed

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  10. Correlation of ultrasonographic appearance of lesions and cytologic and histologic diagnoses in splenic aspirates from dogs and cats: 32 cases (2002-2005).

    PubMed

    Ballegeer, Elizabeth A; Forrest, Lisa J; Dickinson, Ryan M; Schutten, Melissa M; Delaney, Fern A; Young, Karen M

    2007-03-01

    To determine the accuracy of cytologic diagnosis, compared with histologic diagnosis, in determination of disease in ultrasound-guided fine-needle aspirates of splenic lesions. Retrospective study. Splenic specimens from 29 dogs and 3 cats. Records were searched for dogs and cats that had undergone ultrasound-guided splenic aspiration. Criteria for inclusion were ultrasonographic identification of splenic lesions and cytologic and histologic evaluation of tissue from the same lesion. Cytologic samples were obtained by fine-needle aspiration, and histologic specimens were obtained via surgical biopsy, ultrasound-guided biopsy, or necropsy. Cytologic diagnoses corresponded with histologic diagnoses in 19 of 31 (61.3%) cases and differed in 5 of 31(16.1%) cases, and 1 aspirate was inadequate for evaluation. In 7 of 31 (22.6%) cases, histologic evaluation of tissue architecture was required to distinguish between reactive and neoplastic conditions. On the basis of histologic diagnosis in 14 animals with nonneoplastic conditions, the cytologic diagnosis was correct in 11 cases, not definitive in 2 cases, and incorrect in 1 case. In 17 animals with malignant neoplastic diseases, the cytologic diagnosis was correct in 8 cases, not definitive but consistent with possible neoplasia in 5 cases, and incorrect in 4 cases. Multiple similar-appearing nodules were significantly associated with malignancy, whereas single lesions were more often benign. Ultrasound-guided aspiration of splenic lesions is a minimally invasive tool for obtaining specimens for cytologic evaluation. Although cytologic diagnoses often reflect histologic results, if missampling or incomplete sampling occurs or tissue architecture is required to distinguish between reactive and neoplastic conditions, accurate diagnosis with fine-needle aspiration may not be possible.

  11. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    PubMed Central

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  12. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca

    2002-08-15

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yieldedmore » no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)« less

  13. Thyroid Nodule Classification in Ultrasound Images by Fine-Tuning Deep Convolutional Neural Network.

    PubMed

    Chi, Jianning; Walia, Ekta; Babyn, Paul; Wang, Jimmy; Groot, Gary; Eramian, Mark

    2017-08-01

    With many thyroid nodules being incidentally detected, it is important to identify as many malignant nodules as possible while excluding those that are highly likely to be benign from fine needle aspiration (FNA) biopsies or surgeries. This paper presents a computer-aided diagnosis (CAD) system for classifying thyroid nodules in ultrasound images. We use deep learning approach to extract features from thyroid ultrasound images. Ultrasound images are pre-processed to calibrate their scale and remove the artifacts. A pre-trained GoogLeNet model is then fine-tuned using the pre-processed image samples which leads to superior feature extraction. The extracted features of the thyroid ultrasound images are sent to a Cost-sensitive Random Forest classifier to classify the images into "malignant" and "benign" cases. The experimental results show the proposed fine-tuned GoogLeNet model achieves excellent classification performance, attaining 98.29% classification accuracy, 99.10% sensitivity and 93.90% specificity for the images in an open access database (Pedraza et al. 16), while 96.34% classification accuracy, 86% sensitivity and 99% specificity for the images in our local health region database.

  14. Diagnosis of Metastasis to the Thyroid Gland: Comparison of Core-Needle Biopsy and Fine-Needle Aspiration.

    PubMed

    Choi, Sang Hyun; Baek, Jung Hwan; Ha, Eun Ju; Choi, Young Jun; Song, Dong Eun; Kim, Jae Kyun; Chung, Ki-Wook; Kim, Tae Yong; Lee, Jeong Hyun

    2016-04-01

    Early detection and diagnosis of metastasis to the thyroid gland is important. This study aims to evaluate the clinical value of core-needle biopsy (CNB) by comparing the results of CNB and fine-needle aspiration (FNA) in patients with clinically suspected metastasis to the thyroid gland. Case series with chart review. Tertiary referral practice. Fifty-two thyroid nodules from 52 patients with clinically suspected metastasis to the thyroid gland (mean age, 62.8 years). Of these 52 patients, FNA was initially used in 41 patients and CNB in 20 patients (11 patients as the initial approach and 9 patients after inconclusive FNA results). Ultrasound features of metastasis to the thyroid gland were evaluated. The diagnostic performance, repeated diagnostic examination rate, and diagnostic surgery rate were evaluated for FNA and CNB. Among these 52 patients, 46 were diagnosed with thyroid metastases and 6 were diagnosed with primary thyroid cancer. Common ultrasound features were an ovoid to round shape (58.7%), ill-defined margin (56.5%), hypoechogenicity (65.2%), and no calcifications (87.0%). Core-needle biopsy achieved a significantly higher sensitivity than FNA (100.0% vs 58.6%, P = .008) without any false-negative results. Both the repeated diagnostic examination rate and the diagnostic surgery rate were significantly lower in CNB than in FNA (5.0% vs 46.3%, P = .001, and 5.0% vs 34.1%, P = .013, respectively). In cases of known rare primary malignancy, nontypical ultrasound features of primary thyroid malignancy, and need for an additional immunohistochemical analysis, CNB may be primarily considered. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  15. Therapeutic aspects of endoscopic ultrasound

    NASA Astrophysics Data System (ADS)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  16. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    PubMed Central

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  17. Ultrasound-Guided Transcutaneous Needle Biopsy of the Base of the Tongue and Floor of the Mouth From a Submental Approach.

    PubMed

    Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M

    2016-05-01

    Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.

  18. Accuracy of electromyography needle placement in cadavers: non-guided vs. ultrasound guided.

    PubMed

    Boon, Andrea J; Oney-Marlow, Theresa M; Murthy, Naveen S; Harper, Charles M; McNamara, Terrence R; Smith, Jay

    2011-07-01

    Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory. Copyright © 2011 Wiley Periodicals, Inc.

  19. ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION IN THE DIAGNOSIS OF ADRENAL METASTASIS IN A HIGH-RISK POPULATION.

    PubMed

    Zhang, Catherine D; Erickson, Dana; Levy, Michael J; Gleeson, Ferga C; Salomao, Diva R; Delivanis, Danae A; Bancos, Irina

    2017-12-01

    While the left adrenal gland is readily accessible via endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), data regarding the utility of EUS-FNA in the diagnosis of adrenal lesions remain limited. We aimed to ( 1) describe the clinical context, adverse event rate, and diagnostic performance of EUS-FNA, and ( 2) compare the safety profile and diagnostic accuracy of EUS-FNA with percutaneous adrenal biopsy. Single-center, retrospective cohort study. Medical records of patients who underwent adrenal EUS-FNA from 2005-2016 were reviewed. Biopsy outcomes were evaluated using a predefined reference standard. Results were compared to patients who underwent percutaneous biopsy (n = 419; 1994-2014) at the same institution. A total of 121 patients underwent EUS-FNA of 122 adrenal lesions (left [n = 121]; right [n = 1]; mean lesion size, 1.8 cm). Cytology was positive for malignancy in 35 (29%), suspicious for malignancy in 1 (1%), atypical in 1 (1%), negative for malignancy in 81 (66%), and nondiagnostic in 4 (3%). No adverse events were reported. EUS-FNA diagnosed metastasis with a sensitivity of 100%, specificity of 97.4%, positive predictive value of 91.7%, and negative predictive value of 100%. When compared to percutaneous biopsy, lesion size (1.8 cm vs. 3.7 cm; P<.001) and biopsy site (99% vs. 62% left adrenal; P<.001) were significantly different. EUS-FNA adverse event rate was lower than percutaneous biopsy (0% vs. 4%; P = .024), but nondiagnostic rates were similar (3.3% vs. 4.8%; P = .48). EUS-FNA is a sensitive technique to sample adrenal lesions in patients at high risk for adrenal metastasis with fewer adverse events compared to percutaneous biopsy. CI = confidence interval CT = computed tomography EUS-FNA = endoscopic ultrasound-guided fine-needle aspiration NPV = negative predictive value PPV = positive predictive value TUS = transabdominal ultra-sound.

  20. A resected perivascular epithelioid cell tumor (PEComa) of the pancreas diagnosed using endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Okuwaki, Kosuke; Kida, Mitsuhiro; Masutani, Hironori; Yamauchi, Hiroshi; Katagiri, Hiroyuki; Mikami, Tetuo; Miyazawa, Shiro; Iwai, Tomohisa; Takezawa, Miyoko; Imaizumi, Hiroshi; Koizumi, Wasaburo

    2013-01-01

    Primary perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare. We herein report our experience with a patient who had a primary PEComa of the pancreas that was diagnosed by the preoperative histopathological examination of a biopsy specimen obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). The patient was a 43-year-old woman whose chief complaint was abdominal pain. Imaging studies revealed a pancreatic tumor. Gastrointestinal stromal tumor (GIST), solid pseudopapillary tumor and neuroendocrine tumor were considered in the differential diagnosis. A histopathological examination of a specimen of the tumor obtained using EUS-FNA showed spindle-shaped tumor cells with enlarged nuclei and eosinophilic cytoplasm. The tumor cells proliferated in a sheet-like fashion and stained positive for the melanoma-associated antigen HMB-45. A PEComa was thus diagnosed. If an adequate tumor specimen can be obtained using EUS-FNA, immunostaining may facilitate the diagnosis of extremely rare diseases and therefore assist in deciding the treatment policy.

  1. P-LUM-08: Endoscopic ultrasound-guided fine needle aspiration: A new modality to diagnose peritoneal tuberculosis in the presence of decompensated cirrhosis – a case series

    PubMed Central

    Daswani, Ravi; Singla, Vikas; Arora, Anil; Sharma, Praveen; Bansal, Naresh; Kumar, Ashish

    2017-01-01

    The gold standard for diagnosis of peritoneal tuberculosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the nonspecific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low, and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Thus, there is an urgent need to explore newer diagnostic modalities, especially those that can provide perioneal tissue by less invasive means. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal tuberculosis (TB). We hereby report the use of EUS- FNA of the peritoneum in five patients with decompensated cirrhosis, in whom the diagnosis could not be confirmed by other means; thus, we propose EUS-FNA of the peritoneum as a new, safe, and unexplored technique for diagnosis of peritoneal TB.

  2. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    PubMed

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  3. High-resolution endoscopic ultrasound imaging and the number of needle passages are significant factors predicting high yield of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses without an on-site cytopathologist

    PubMed Central

    Jeong, Seok Hoo; Yoon, Hyun Hwa; Kim, Eui Joo; Kim, Yoon Jae; Kim, Yeon Suk; Cho, Jae Hee

    2017-01-01

    Abstract Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the accurate diagnostic method for pancreatic masses and its accuracy is affected by various FNA methods and EUS equipment. Therefore, we aimed to elucidate the instrumental and methodologic factors for determining the diagnostic yield of EUS-FNA for pancreatic solid masses without an on-site cytopathology evaluation. We retrospectively reviewed the medical records of 260 patients (265 pancreatic solid masses) who underwent EUS-FNA. We compared historical conventional EUS groups with high-resolution imaging devices and finally analyzed various factors affecting EUS-FNA accuracy. In total, 265 pancreatic solid masses of 260 patients were included in this study. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of EUS-FNA for pancreatic solid masses without on-site cytopathology evaluation were 83.4%, 81.8%, 100.0%, 100.0%, and 34.3%, respectively. In comparison with conventional image group, high-resolution image group showed the increased accuracy, sensitivity and specificity of EUS-FNA (71.3% vs 92.7%, 68.9% vs 91.9%, and 100% vs 100%, respectively). On the multivariate analysis with various instrumental and methodologic factors, high-resolution imaging (P = 0.040, odds ratio = 3.28) and 3 or more needle passes (P = 0.039, odds ratio = 2.41) were important factors affecting diagnostic yield of pancreatic solid masses. High-resolution imaging and 3 or more passes were the most significant factors influencing diagnostic yield of EUS-FNA in patients with pancreatic solid masses without an on-site cytopathologist. PMID:28079803

  4. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology.

    PubMed

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  5. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology

    PubMed Central

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation. PMID:28100998

  6. Rare pancreatic neoplasms: the utility of endoscopic ultrasound-guided fine-needle aspiration-a large single center study.

    PubMed

    Imaoka, Hiroshi; Yamao, Kenji; Bhatia, Vikram; Shimizu, Yasuhiro; Yatabe, Yasushi; Koshikawa, Takashi; Kinoshita, Yoshikazu

    2009-01-01

    Tumors other than ductal adenocarcinomas constitute 10%-15% of all pancreatic tumors. We describe the performance and pitfalls of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosis of these rare pancreatic tumors and their characteristic cytopathological features. The records of 455 pancreatic fine-needle aspiration procedures done between March 1997 and August 2006 at Aichi Cancer Center, Nagoya, Japan, were reviewed. Besides cytology, aspirated material was routinely submitted in formalin for cell-block analysis. The reference standard for final diagnosis was surgical pathology from resected specimens. Twenty-eight rare (nonductal adenocarcinomas) pancreatic tumors were identified. Overall, EUS-FNA with the results of cytology, cell-block processing, and immunohistochemistry could correctly diagnose the type of neoplasm in 19 (67.9%) cases. EUS-FNA could distinguish benign from malignant rare tumors with a sensitivity of 69.2%, a specificity of 100%, positive predictive value of 100%, negative predictive value of 79.0%, and accuracy of 85.7%. None of three malignant pancreatic endocrine neoplasms could be diagnosed as malignant. An adequate core tissue sample could be obtained in 21 cases (75.0%) and provide a histopathological diagnosis in 19 (67.9%) cases. EUS-FNA could change the presumptive diagnosis in 11 (39.3%) cases. Specific immunochemical studies were useful adjuncts to the diagnosis. No major or minor complication was noted in any patient. Pancreatic neoplasms other than ductal adenocarcinomas have diverse imaging and histopathological features. EUS-FNA is accurate and safe for their identification.

  7. Endoscopic Ultrasound of the Upper Gastrointestinal Tract and Mediastinum: Diagnosis and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prasad, Priyajit; Wittmann, Johannes; Pereira, Stephen P.

    2006-12-15

    Endoscopic ultrasound (EUS) has developed significantly over the last two decades and has had a considerable impact on the imaging and staging of mass lesions within or in close proximity to the gastrointestinal (GI) tract. In conjunction with conventional imaging such as helical computed tomography and magnetic resonance imaging, the indications for EUS include (1) differentiating between benign and malignant lesions of the mediastinum and upper GI tract, (2) staging malignant tumors of the lung, esophagus, stomach, and pancreas prior to surgery or oncological treatment, (3) excluding common bile duct stones before laparoscopic cholecystectomy, thereby avoiding the need for endoscopicmore » retrograde cholangiopancreatography (ERCP) in some patients, and (4) assessing suspected lesions that are either equivocal or not seen on conventional imaging. In recent years, EUS has charted a course similar to that taken by ERCP, evolving from a purely diagnostic modality to one that is interventional and therapeutic. These indications include (5) obtaining a tissue diagnosis by EUS-guided fine-needle aspiration or trucut-type needle biopsy and (6) providing therapy such as coeliac plexus neurolysis and pancreatic pseudocyst drainage-in many cases, more accurately and safely than conventional techniques. Emerging investigational techniques include EUS-guided enteric anastomosis formation and fine-needle injection therapy for malignant disease.« less

  8. Needle tip visibility in 3D ultrasound images

    NASA Astrophysics Data System (ADS)

    Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo

    2017-03-01

    Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.

  9. Endoscopic ultrasound in gastroenterology: from diagnosis to therapeutic implications.

    PubMed

    Mekky, Mohamed A; Abbas, Wael A

    2014-06-28

    Since its advent in 1980, the scope of endoscopic ultrasound (EUS) has grown to include a wide range of indications, and it is now being incorporated as an integral part of everyday practice in the field of gastroenterology. Its use is extending from an adjuvant imaging aid to utilization as a therapeutic tool for various gastrointestinal disorders. EUS was first used to visualize remote organs, such as the pancreas and abdominal lymph nodes. When fine needle aspiration was introduced, the indications for EUS expanded to include tissue sampling for diagnostic purposes. At the same time, the needle can be used to convey a potential therapy to the internal organs, allowing access to remote sites. In this review, we aim to highlight the expanding spectrum of EUS indications and uses in the field of gastroenterology.

  10. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    PubMed

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (p<0.001). There were no differences in the proportion of histologic core (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  11. Hormones, Women and Breast Cancer

    MedlinePlus

    ... sure that it is benign (not cancer). These tests can include • A mammogram • A breast ultrasound • A sample of cells from the lump (called a fine needle aspirate) • A sample of a piece of tissue from the lump (called a core biopsy) Possible Symptoms of Breast Cancer • A lump • ...

  12. Comparative study between ultrasound-guided fine needle aspiration cytology of axillary lymph nodes and sentinel lymph node histopathology in early-stage breast cancer

    PubMed Central

    Cardoso-Coelho, Lívio Portela; Borges, Rafael Soares; Alencar, Airlane Pereira; Cardoso-Campos-Verdes, Larysse Maira; da Silva-Sampaio, João Paulo; Borges, Umbelina Soares; Gebrim, Luiz Henrique; da Silva, Benedito Borges

    2017-01-01

    The replacement of sentinel lymph node biopsy (SNB) by ultrasound-guided fine-needle aspiration (US-guided FNA) cytology of axillary lymph nodes is controversial, despite the simplicity and reduced cost of the latter. In the present study, US-guided FNA was performed in 27 patients with early-stage breast cancer for comparison with SNB. Data were analyzed by calculation of sample proportions. Tumor subtypes included invasive ductal carcinoma (85%), invasive lobular carcinoma (7%), and tubular and metaplastic carcinoma (4%). FNA had a sensitivity of 45%, specificity of 100%, positive predictive value of 100% and a negative predictive value of 73%. Axillary lymph node cytology obtained by US guided-FNA in patients with breast cancer had a specificity similar to that of sentinel lymph node histopathology in the presence of axillary node metastases. However, when lymph node cytology is negative, it does not exclude the existence of metastatic implants, due to its low sensitivity in comparison to sentinel lymph node histopathology. PMID:28521436

  13. Endobronchial ultrasound-guided transbronchial needle aspiration of pulmonary artery tumors: A systematic review (with video).

    PubMed

    Harris, Kassem; Modi, Kush; Kumar, Abhishek; Dhillon, Samjot Singh

    2015-01-01

    Convex probe endobronchial ultrasound (CP-EBUS) was originally introduced as a diagnostic and staging tool for lung cancer and subsequently utilized for diagnosis of other malignant and benign mediastinal diseases such as melanoma, lymphoma, and sarcoidosis. More recently, CP-EBUS has been successfully used for the visualization and diagnosis of pulmonary emboli and other vascular lesions including primary and metastatic pulmonary artery (PA) tumors. In this review, we will underline the role of EBUS-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of pulmonary arterial tumors such as sarcomas and tumor emboli. We will concisely discuss the clinical applications of EBUS-TBNA and the types of pulmonary arterial tumors and their different diagnostic modalities. We searched the Cochrane Library and PubMed from 2004 to 2014 to provide the most comprehensive review. Only 10 cases of EBUS-TBNA for intravascular lesions were identified in the literature. Although many cases of EBUS and EUS-guided transvascular tumor biopsies were described in the literature, there were no reported cases of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for intravascular tumor biopsies. Except for one paper, all cases were published as case reports.

  14. To fine needle aspiration or not? An endosonographer's approach to pancreatic cystic lesions

    PubMed Central

    But, David Yiu-Kuen; Poley, Jan-Werner

    2014-01-01

    Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is an established diagnostic tool in the management of pancreatic cystic lesions (PCLs). Due to the proximity to the target lesion, the fine diagnostic needle travels through only minimal normal tissues. The risks of bleeding, pancreatitis and infection are small. Valuable diagnostic morphological information can be obtained by EUS before the use of FNA. The additional cytopathologic and cyst fluid analysis for the conventional markers such as amylase, carcinoembryonic antigen (CEA) and CA19.9 improves the diagnostic capability. Pancreatic cyst fluid CEA concentration of 192 ng/mL is generally the most agreed cutoff to differentiate mucinous from non-mucinous lesion. A fluid amylase level of <250 IU/L excludes the diagnosis of pseudocyst. Technical tips of EUS-FNA and the limitations of the procedure are discussed. Promising technique and FNA needle modifications have been described to improve the diagnostic yield at the cytopathologic analysis. The use of novel cyst fluid proteomics and deoxyribonucleic acid-based biomarkers of the PCLs are reviewed. Although it is considered a safe procedure, EUS-FNA is not a routine in every patient. Recommendations of the role of EUS-FNA at various common clinical scenarios are discussed. PMID:24955337

  15. Automatic Robotic Steering of Flexible Needles from 3D Ultrasound Images in Phantoms and Ex Vivo Biological Tissue.

    PubMed

    Mignon, Paul; Poignet, Philippe; Troccaz, Jocelyne

    2018-05-29

    Robotic control of needle bending aims at increasing the precision of percutaneous procedures. Ultrasound feedback is preferable for its clinical ease of use, cost and compactness but raises needle detection issues. In this paper, we propose a complete system dedicated to robotized guidance of a flexible needle under 3D ultrasound imaging. This system includes a medical robot dedicated to transperineal needle positioning and insertion, a rapid path planning for needle steering using bevel-tip needle natural curvature in tissue, and an ultrasound-based automatic needle detection algorithm. Since ultrasound-based automatic needle steering is often made difficult by the needle localization in biological tissue, we quantify the benefit of using flexible echogenic needles for robotized guidance under 3D ultrasound. The "echogenic" term refers to the etching of microstructures on the needle shaft. We prove that these structures improve needle visibility and detection robustness in ultrasound images. We finally present promising results when reaching targets using needle steering. The experiments were conducted with various needles in different media (synthetic phantoms and ex vivo biological tissue). For instance, with nitinol needles the mean accuracy is 1.2 mm (respectively 3.8 mm) in phantoms (resp. biological tissue).

  16. Brief reports: regional anesthesia needles can introduce ultrasound gel into tissues.

    PubMed

    Belavy, David

    2010-09-01

    Anesthesiologists may insert needles through ultrasound gel when performing ultrasound-guided regional anesthesia. In this study, it was determined whether needles carry gel into tissues. Ultrasound gel dyed blue was applied to pork rashers. Tuohy and short-bevel needles were passed through the gel and pork. The needles were then assessed for the presence of ultrasound gel. All needles, including those with stylets, carried gel and tissue within the lumen. Ultrasound gel may be injected around (and perhaps in) nerves during regional anesthesia procedures. Studies are needed to determine the implications of this practice.

  17. Fine needle aspiration cytology of hepatic metastasis from a meningeal hemangiopericytoma. A case report.

    PubMed

    Ghaffar, Hasan; Parwani, Anil; Rosenthal, Dorothy L

    2003-01-01

    Hemangiopericytomas (HPCs) are rare spindle cell tumors, constituting 2.5% of soft tissue neoplasms. Few reports have addressed the fine needle aspiration (FNA) cytology of HPC. We describe the FNA biopsy (FNAB) findings in a 44-year-old patient with a previously resected meningeal hemangiopericytoma. The patient underwent ultrasound-guided FNAB of a 16.0-cm, radiographically heterogeneous density in the liver. The FNA smear showed crowded, ovoid to spindle-shaped cells with poorly defined, scant cytoplasm. The neoplastic cells were positive for CD34 and negative for CD31, factor VIII, glial fibrillary acid protein and cytokeratin AE1/AE3, supporting a diagnosis of HPC and compatible with metastasis from the patient's cerebral tumor. This case documents the role of FNA cytology in confirming HPC.

  18. Ultrasound-guided fine-needle aspiration of a posterior neck dedifferentiated liposarcoma with MDM2 fluorescence in situ hybridization performed on a Pap-stained smear.

    PubMed

    Zreik, Riyam; Soyalp, Krystal; Ruiz, Steve; Ward, Russell; Dobin, Sheila; Chen, Xiangbai; Liu, Lina; Rao, Arundhati

    2015-04-01

    Head and neck liposarcomas, while rare, tend to be subcutaneous and well-differentiated. Dedifferentiated liposarcomas of the head and neck are exceedingly rare in the literature. We present a case of a dedifferentiated liposarcoma arising in the soft tissue of the posterior neck of an 86-year-old man and diagnosed by fine-needle aspiration. Aspirate smears showed a dual population of atypical lipomatous and spindled cells. MDM2 (murine double minute 2) amplification was demonstrated on a Pap-stained smear using fluorescence in situ hybridization (FISH). To the best of our knowledge, this is the first report of MDM2 FISH amplification in a liposarcoma performed on an aspirate smear. © 2014 Wiley Periodicals, Inc.

  19. Toward optical guidance during endoscopic ultrasound-guided fine needle aspirations of pancreatic masses using single fiber reflectance spectroscopy: a feasibility study

    NASA Astrophysics Data System (ADS)

    Stegehuis, Paulien L.; Boogerd, Leonora S. F.; Inderson, Akin; Veenendaal, Roeland A.; van Gerven, P.; Bonsing, Bert A.; Sven Mieog, J.; Amelink, Arjen; Veselic, Maud; Morreau, Hans; van de Velde, Cornelis J. H.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Robinson, Dominic J.; Vahrmeijer, Alexander L.

    2017-02-01

    Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ˜5 min. An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p=0.038; 166 μmol/L versus 17 μmol/L, p=0.039, respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.

  20. Endoscopic Ultrasound-Guided Fine Needle Aspiration: From the Past to the Future

    PubMed Central

    Costache, Mădălin-Ionuț; Iordache, Sevastița; Karstensen, John Gásdal; Săftoiu, Adrian; Vilmann, Peter

    2013-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a technique which allows the study of cells obtained through aspiration in different locations near the gastrointestinal tract. EUS-FNA is used to acquire tissue from mucosal/submucosal tumors, as well as peri-intestinal structures including lymph nodes, pancreas, adrenal gland, gallbladder, bile duct, liver, kidney, lung, etc. The pancreas and lymph nodes are still the most common organs targeted in EUS-FNA. The overall accuracy of EUS is superior to computed tomography scan and magnetic resonance imaging for detecting pancreatic lesions. In most cases it is possible to avoid unnecessary surgical interventions in advanced pancreatic cancer, and EUS is considered the preferred method for loco-regional staging of pancreatic cancer. FNA improved the sensitivity and specificity compared to EUS imaging alone in detection of malignant lymph nodes. The negative predictive value of EUS-FNA is relatively low. The presence of a cytopathologist during EUS-FNA improves the diagnostic yield, decreasing unsatisfactory samples or need for additional passes, and consequently the procedural time. The size of the needle is another factor that could modify the diagnostic accuracy of EUS-FNA. Even though the EUS-FNA technique started in early nineteen's, there are many remarkable progresses culminating nowadays with the discovery and performance of needle-based confocal laser endomicroscopy. Last, but not least, identification and quantification of potential molecular markers for pancreatic cancer on cellular samples obtained by EUS-FNA could be a promising approach for the diagnosis of solid pancreatic masses. PMID:24949369

  1. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    PubMed Central

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  2. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    NASA Astrophysics Data System (ADS)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  3. Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis

    PubMed Central

    Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao

    2013-01-01

    AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631

  4. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    PubMed

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  5. The relevance of ultrasound imaging of suspicious axillary lymph nodes and fine-needle aspiration biopsy in the post ACOSOG Z11 era in early breast cancer

    PubMed Central

    Vijayaraghavan, Gopal R.; Vedantham, Srinivasan; Kataoka, Milliam; DeBenedectis, Carolynn; Quinlan, Robert

    2016-01-01

    Rationale and Objective Evaluation of nodal involvement in early-stage breast cancers (T1 or T2) changed following the Z11 trial; however, not all patients meet the Z11 inclusion criteria. Hence, the relevance of ultrasound imaging of the axilla and fine-needle aspiration biopsy (FNA) in early-stage breast cancers was investigated. Materials and Methods In this single-center, retrospective study, 758 subjects had pathology-verified breast cancer diagnosis over a 3-year period, of which 128 subjects with T1/T2 breast tumors had abnormal axillary lymph nodes on ultrasound, had FNA, and proceeded to axillary surgery. Ultrasound images were reviewed and analyzed using multivariable logistic regression to identify the features predictive of positive FNA. Accuracy of FNA was quantified as the area under the receiver operating characteristic curve with axillary surgery as reference standard. Results Of 128 subjects, 61 and 65 were positive on FNA and axillary surgery, respectively. Sensitivity, specificity, positive- and negative-predictive values of FNA were 52/65 (80%), 54/63 (85.7%), 52/61(85.2%) and 54/67 (80.5%), respectively. After adjusting for neoadjuvant chemotherapy between FNA and surgery, a positive FNA was associated with higher likelihood for positive axillary surgery (odds ratio: 22.7; 95% CI: 7.2–71.3, p<0.0001), and the accuracy of FNA was 0.801 (95% CI: 0.727–0.876). Among ultrasound imaging features, cortical thickness and abnormal hilum were predictive (p<0.017) of positive FNA with accuracy of 0.817 (95% CI: 0.741–0.893). Conclusion Ultrasound imaging and FNA can play an important role in the management of early breast cancers even in the post-Z11 era. Higher weightage can be accorded to cortical thickness and hilum during ultrasound evaluation. PMID:27916595

  6. Impact of endoscopic ultrasound-guided fine-needle aspiration in prospective liver transplant recipients with hepatocellular carcinoma and lymphadenopathy.

    PubMed

    Choudhary, Narendra S; Puri, Rajesh; Saigal, Sanjiv; Bhangui, Prashant; Saraf, Neeraj; Shah, Vinit; Nasa, Mukesh; Sarin, Haimanti; Guleria, Mridula; Sud, Randhir; Soin, Arvinder S

    2016-11-01

    Diagnosis of metastatic disease is important in patients with cirrhosis and hepatocellular carcinoma (HCC) to prevent futile liver transplantation. Some of these patients have metastatic lymphadenopathy; however, it is difficult to perform percutaneous fine-needle aspiration due to presence of collateral and anatomic location. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) of lymph nodes offers several advantages like real-time vision, proximity to target, and avoidance of collaterals. The aim of this study was to look for metastatic lymphadenopathy by EUS-guided FNA (EUS-FNA) in prospective liver transplant recipients with HCC. A prospective study was conducted from January 2013 to January 2016 at a tertiary care center. All prospective liver transplant recipients with HCC had PET-CT and bone scan to look for metastatic disease. EUS-FNA was done in patients with abdominal or mediastinal lymphadenopathy and no evidence of extrahepatic disease. Data is shown as median (25-75 interquartile range). EUS-guided FNA was done for 50 patients (42 abdominal and 8 mediastinal lymph nodes), age 57 (53-62) years, Child-Turcotte-Pugh 7 (6-9), and model for end-stage liver disease 10 (7-16). FNA material was adequate in 92% patients, metastasis in 15 (30%), granulomatous lymphadenopathy in 4 (8%), and reactive change in 27 patients (54%). The material was inadequate for diagnosis in 4 (8%) patients. Thus, EUS-guided FNA precluded transplantation in 30% of patients with lymphadenopathy, and 4 (8%) patients received anti-tubercular therapy before liver transplantation. In patients with HCC and lymphadenopathy, EUS-guided FNA detected metastatic disease and precluded liver transplantation in approximately one third of patients.

  7. Tubercular thyroid abscess

    PubMed Central

    Kumar, Awanish; Pahwa, Harvinder Singh; Srivastava, Rohit; Khan, Khursheed Alam

    2013-01-01

    We encountered a patient who presented with neck swelling, difficulty in swallowing, voice change along with systemic features such as evening rise of temperature, chronic cough and weight loss. Ultrasonography of the thyroid gland revealed two cystic swellings. An ultrasound guided fine needle aspiration cytology was suggestive of tubercular abscess. The patient responded well to antigravity aspiration of the swellings and antitubercular treatment. PMID:23814203

  8. Diagnosis of metastatic pancreatic mesenchymal tumors by endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Varghese, Linda; Ngae, Min Yi; Wilson, Andrew P; Crowder, Clinton D; Gulbahce, H Evin; Pambuccian, Stefan E

    2009-11-01

    Involvement of the pancreas by metastatic sarcoma is rare, and can prove challenging to differentiate from sarcomatoid carcinomas which occur more commonly. The endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) technique has been successfully used for the diagnosis of pancreatic carcinomas whether primary or metastatic, and is now considered the most effective noninvasive method for the identification of pancreatic metastases. However, to date very few reports detail the diagnosis of mesenchymal neoplasms by EUS-FNA. Herein, we report a series of four patients who underwent EUS-FNA of the pancreas, where the diagnosis of metastatic sarcoma was made based on morphology and ancillary studies. The cases include metastases of leiomyosarcoma, liposarcoma, alveolar rhabdomyosarcoma, and solitary fibrous tumor. The history of a primary sarcoma of the chest wall, mediastinum, and respectively lower extremity was known for the first three of these patients while in the case of the solitary fibrous tumor a remote history of a paraspinal "hemangiopericytoma" was only elicited after the EUS-FNA diagnosis was made. We conclude that EUS-FNA is efficient and accurate in providing a diagnosis of sarcoma, even in patients without a known primary sarcoma, thus allowing institution of therapy without additional biopsies.

  9. Rapid diagnosis of liver cancer by ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Huber, K; Heuhold, N

    1987-01-01

    Because of the relatively favorable prognosis to the patient with early detected hepatocarcinoma followed by surgical treatment if resection is possible, it is important to differentiate quickly between primary and secondary liver cancer. Ultrasound-guided percutaneous fine needle aspiration biopsy (US-FNAB) was used as a first diagnostic measure in patients with sonographic evidence of liver tumors. Biopsies were done under sonographic control and antiseptic conditions from the center and the border zone of solid tumors of the liver, and the aspirated cell material was air dried on glass slides and Giemsa stained. The cytologic diagnosis was proved by clinical course and in most cases by surgical or autoptic histology. Cytologic evaluation lead in 15 cases to the diagnosis of definitive or suspicious malignant liver disease; the sensitivity was 93% and the specificity was 87%. One case classified as suspicious for malignancy by cytologic examination could be identified as cirrhotic nodule by further investigations. In none of the patients did we find complications from the biopsy procedure. From these data it is concluded that US-FNAB can serve as a rapid, inexpensive, safe, and highly accurate first diagnostic step in patients with solid lesions of the liver.

  10. Papanicolaou Society of Cytopathology new guidelines have a greater ability of risk stratification for pancreatic endoscopic ultrasound-guided fine-needle aspiration specimens

    PubMed Central

    Chen, Bo; Zhao, Yu; Gu, Jiangang; Wu, Huanwen; Liang, Zhiyong; Meng, Zhilan

    2017-01-01

    The Papanicolaou Society of Cytopathology has recently proposed a standardized terminology and nomenclature guidelines for pancreatic cytology. However the risk of malignancy associated with the new guidelines has been scarcely studied. In this study, a series of pancreatic cytology cases obtained by endoscopic ultrasound-guided fine-needle aspiration from 294 Chinese patients were retrospectively re-categorized into six categories according the new guidelines. The risks of malignancy were 18.1% for “negative,” 20.0% for “neoplastic,” 57.1% for “nondiagnostic,” 69.2% for “atypical,” 87.5% for “suspicious,” and 100.0% for “positive” respectively. The area under the receiver operating characteristic curve was 0.93 (95% Confidence Interval, 0.90-0.96), which was significantly higher than that associated with old classification system (0.82; 95% Confidence Interval, 0.77-0.87) conventionally used in China. Our investigation demonstrated that the new guidelines have a greater ability of risk stratification than the old classification system conventionally used in China. This may be helpful in giving better predictions of malignancy, thus leading to more personalized treatment strategies. PMID:28042957

  11. Endoscopic ultrasound elastography: Current status and future perspectives

    PubMed Central

    Cui, Xin-Wu; Chang, Jian-Min; Kan, Quan-Cheng; Chiorean, Liliana; Ignee, Andre; Dietrich, Christoph F

    2015-01-01

    Elastography is a new ultrasound modality that provides images and measurements related to tissue stiffness. Endoscopic ultrasound (EUS) has played an important role in the diagnosis and management of numerous abdominal and mediastinal diseases. Elastography by means of EUS examination can assess the elasticity of tumors in the proximity of the digestive tract that are hard to reach with conventional transcutaneous ultrasound probes, such as pancreatic masses and mediastinal or abdominal lymph nodes, thus improving the diagnostic yield of the procedure. Results from previous studies have promised benefits for EUS elastography in the differential diagnosis of lymph nodes, as well as for assessing masses with pancreatic or gastrointestinal (GI) tract locations. It is important to mention that EUS elastography is not considered a modality that can replace biopsy. However, it may be a useful adjunct, improving the accuracy of EUS-fine needle aspiration biopsy (EUS-FNAB) by selecting the most suspicious area to be targeted. Even more, it may be useful for guiding further clinical management when EUS-FNAB is negative or inconclusive. In the present paper we will discuss the current knowledge of EUS elastography, including the technical aspects, along with its applications in the differential diagnosis between benign and malignant solid pancreatic masses and lymph nodes, as well as its aid in the differentiation between normal pancreatic tissues and chronic pancreatitis. Moreover, the emergent indication and future perspectives are summarized, such as the benefit of EUS elastography in EUS-guided fine needle aspiration biopsy, and its uses for characterization of lesions in liver, biliary tract, adrenal glands and GI tract. PMID:26715804

  12. Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers.

    PubMed

    Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György

    2009-08-01

    Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers at positions (+/- standard deviation) -0.53 +/- 0.16, -0.16 +/- 0.14, and -0.30 +/- 0.16 mm using a gain of 15 dB. The minus sign indicates that the needle tips were detected more proximally than the actual position of the needle tip. When using a gain of -15 dB the mean values of two observers resulted in -0.62 +/- 0.08 and -0.51 +/- 0.12 mm. Additionally an alternative approach to the direct needle tip definition was investigated. Two observers detected the solid part of the needle tip in sagittal images. This solid part, often named as "dead space end," is the distance between the needle tip and the beginning of the hollow part of the implant needle. The dead space end is 6.2 mm for the investigated needle type. Two users found mean values of -6.70 +/- 0.16 and -7.00 +/- 0.06 mm, respectively, for 15 dB gain and -6.90 +/- 0.09 and -7.02 +/- 0.06 mm using the -15 dB gain setting. The results show that ultrasound-based needle tip definition in sagittal viewing mode is accurate. The inter- and intraobserver errors should, however, be taken into account. A lower gain setting of the ultrasound system reduces the intraobserver error.

  13. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session

    PubMed Central

    Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.

    2014-01-01

    Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096

  14. Endoscopic ultrasound (EUS) guided fine needle biopsy (FNB) with the Procore™ needle provides inadequate material for the histological diagnosis of early chronic pancreatitis.

    PubMed

    Iglesias García, Julio; Lariño-Noia, José; Abdulkader Nallib, Ihab; Lindkvist, Björn; Domínguez-Muñoz, J Enrique

    2018-05-03

    diagnosis of early chronic pancreatitis (CP) is hampered due to the low accuracy of current imaging techniques and the absence of methods for histological confirmation. We aimed to evaluate the efficacy of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for the histological diagnosis of early CP. a prospective, cross-sectional, single-center study was designed. Consecutive patients referred for EUS with a clinical suspicion of CP were evaluated for inclusion into the study. Inclusion criteria were age > 18 years and indeterminate EUS findings for the diagnosis of CP according to the Rosemont classification. EUS-FNB of the body of the pancreas was performed with Procore™ needles. Tissue samples were immersed into a methanol-based buffered preservative solution for cytohistological evaluation. The quality of the samples obtained and the histological findings were evaluated. Procedure-related complications were recorded. the study was stopped after eleven patients were included due to safety concerns and poor diagnostic yield. The mean age of the patients was 50.3 years (range 33-70 years) and six were male. Samples were of poor quality in five cases, but were sufficient for cell-block evaluation. An inflammatory infiltration with mild fibrosis was identified in two cases and neither inflammatory infiltration nor fibrosis was identified in three cases. With regard to the other six cases, isolated inflammatory cells were observed in one case, although the cellularity was poor and unsuitable for cytological evaluation in five cases. There was one major complication (9.1%) of acute pancreatitis that required hospitalization for 48 hours. EUS-FNB is technically feasible in patients with EUS findings categorized as indeterminate for a CP diagnosis. However, the diagnostic yield is poor and there is a non-negligible risk of complications.

  15. Needle tip visualization by bevel-point ultrasound generator and prototype photoacoustic imaging system

    NASA Astrophysics Data System (ADS)

    Irisawa, Kaku; Murakoshi, Dai; Hashimoto, Atsushi; Yamamoto, Katsuya; Hayakawa, Toshiro

    2017-03-01

    Visualization of the tip of medical devices like needles or catheters under ultrasound imaging has been a continuous topic since the early 1980's. In this study, a needle tip visualization system utilizing photoacoustic effects is proposed. In order to visualize the needle tip, an optical fiber was inserted into a needle. The optical fiber tip is placed on the needle bevel and affixed with black glue. The pulsed laser light from laser diode was transferred to the optical fiber and converted to ultrasound due to laser light absorption of the black glue and the subsequent photoacoustic effect. The ultrasound is detected by transducer array and reconstructed into photoacoustic images in the ultrasound unit. The photoacoustic image is displayed with a superposed ultrasound B-mode image. As a system evaluation, the needle is punctured into bovine meat and the needle tip is observed with commercialized conventional linear transducers or convex transducers. The needle tip is visualized clearly at 7 and 12 cm depths with linear and convex probes, respectively, even with a steep needle puncture angle of around 90 degrees. Laser and acoustic outputs, and thermal rise at the needle tip, were measured and were well below the limits of the safety standards. Compared with existing needle tip visualization technologies, the photoacoustic needle tip visualization system has potential distinguishable features for clinical procedures related with needle puncture and injection.

  16. The utility of ultrasound in patients with melanoma.

    PubMed

    Uren, Roger F; Sanki, Amira; Thompson, John F

    2007-11-01

    The highest quality gray-scale ultrasound images are obtained with high-frequency transducers; however, such high frequencies do not penetrate more than a few centimeters into body tissue. Fortunately, in patients with melanoma, the structures of interest are close to the skin surface, making them ideal targets for examination with high-resolution ultrasound. These include primary cutaneous melanomas, uveal melanomas and the regional lymph nodes draining the skin that lie in the axilla, groin, neck and other locations. Although ultrasound study of primary melanomas arising in the skin and eye has provided some insights, a major role for ultrasound has evolved recently, to provide early detection of metastatic melanoma in regional lymph nodes. Ultrasound is clearly superior to clinical palpation of the nodes during follow-up and, when combined with guided fine-needle biopsy, allows the earliest possible surgical intervention for regional nodal metastases. In the future the use of ultrasound contrast agents may improve the sensitivity of ultrasound in the detection of very small metastatic deposits.

  17. Fine-needle aspiration cytology of intraductal papillary-mucinous tumors: a retrospective analysis.

    PubMed

    Layfield, Lester J; Cramer, Harvey

    2005-01-01

    Intraductal papillary-mucinous tumor (IPMT) of the pancreas has become the accepted terminology for a group of mucin-producing epithelial proliferations lying within ectatic segments of the main pancreatic duct or its large branches. These neoplasms generally are associated with an indolent course, characteristic endoscopic ultrasonographic (EUS) findings, and a variable histo- and cytomorphology ranging from hyperplasia to carcinoma. Cytological specimens obtained by endoscopic ultrasound-guided or percutaneous fine-needle aspiration (FNA) are characterized by a background containing abundant mucin in which are entrapped single or loosely cohesive clusters of neoplastic cells characteristically showing a goblet-cell morphology. The degree of nuclear atypia, cell crowding, and cell shape varies between smears within a single case and between cases. Cytomorphological examination, when coupled with EUS features, is accurate for the diagnosis of these lesions but often it underdiagnoses the grade of the neoplasm. (c) 2005 Wiley-Liss, Inc.

  18. Multi-resolution Gabor wavelet feature extraction for needle detection in 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Pourtaherian, Arash; Zinger, Svitlana; Mihajlovic, Nenad; de With, Peter H. N.; Huang, Jinfeng; Ng, Gary C.; Korsten, Hendrikus H. M.

    2015-12-01

    Ultrasound imaging is employed for needle guidance in various minimally invasive procedures such as biopsy guidance, regional anesthesia and brachytherapy. Unfortunately, a needle guidance using 2D ultrasound is very challenging, due to a poor needle visibility and a limited field of view. Nowadays, 3D ultrasound systems are available and more widely used. Consequently, with an appropriate 3D image-based needle detection technique, needle guidance and interventions may significantly be improved and simplified. In this paper, we present a multi-resolution Gabor transformation for an automated and reliable extraction of the needle-like structures in a 3D ultrasound volume. We study and identify the best combination of the Gabor wavelet frequencies. High precision in detecting the needle voxels leads to a robust and accurate localization of the needle for the intervention support. Evaluation in several ex-vivo cases shows that the multi-resolution analysis significantly improves the precision of the needle voxel detection from 0.23 to 0.32 at a high recall rate of 0.75 (gain 40%), where a better robustness and confidence were confirmed in the practical experiments.

  19. Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.

    PubMed

    Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M

    2015-05-01

    Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.

  20. Technical Advances in Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition for Pancreatic Cancers: How Can We Get the Best Results with EUS-Guided Fine Needle Aspiration?

    PubMed Central

    Kedia, Prashant; Gaidhane, Monica

    2013-01-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is one of the least invasive and most effective modality in diagnosing pancreatic adenocarcinoma in solid pancreatic lesions, with a higher diagnostic accuracy than cystic tumors. EUS-FNA has been shown to detect tumors less than 3 mm, due to high spatial resolution allowing the detection of very small lesions and vascular invasion, particularly in the pancreatic head and neck, which may not be detected on transverse computed tomography. Furthermore, this minimally invasive procedure is often ideal in the endoscopic procurement of tissue in patients with unresectable tumors. While EUS-FNA has been increasingly used as a diagnostic tool, most studies have collectively looked at all primary pancreatic solid lesions, including lymphomas and pancreatic neuroendocrine neoplasms, whereas very few studies have examined the diagnostic utility of EUS-FNA of pancreatic ductal carcinoma only. As with any novel and advanced endoscopic procedure that may incorporate several practices and approaches, endoscopists have adopted diverse techniques to improve the tissue procurement practice and increase diagnostic accuracy. In this article, we present a review of literature to date and discuss currently practiced EUS-FNA technique, including indications, technical details, equipment, patient selection, and diagnostic accuracy. PMID:24143320

  1. Repeat Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Patients with Suspected Pancreatic Cancer: Diagnostic Yield and Associated Change in Access to Appropriate Care

    PubMed Central

    Stanger, Dylan; Shuster, Constantin; Telford, Jennifer; Lam, Eric

    2016-01-01

    Background. There is a high incidence of inconclusive cytopathology at initial EUS-FNA (endoscopic ultrasound-guided fine-needle aspiration) for suspected malignant pancreatic lesions. To obtain appropriate preoperative or palliative chemotherapy for pancreatic cancer, definitive cytopathology is often required. The utility of repeat EUS-FNA is not well established. Methods. A retrospective cohort study was conducted evaluating the yield of repeat EUS-FNA in determining a cytological diagnosis in patients who had undergone a prior EUS-FNA for diagnosis of suspected malignant pancreatic lesions with inconclusive cytopathology. The wait times to the second procedure and to decisions regarding therapy were calculated. Results. Overall, 45 repeat EUS-FNA procedures were performed over seven years for suspected malignant pancreatic lesions. Cytopathological class (I to IV) changed between first and second EUS-FNA in 32 patients (71%). Of 34 patients with an initially nonconclusive diagnosis, 20 had a conclusive diagnosis (59%) on repeat EUS-FNA. The cumulative yield after repeat EUS-FNA for definite pancreatic adenocarcinoma was 7 (16%). The median time interval between first and second EUS-FNA was 31 (7–175) days. Conclusions. A substantial number of patients had a definitive diagnosis of adenocarcinoma on repeat FNA and were, therefore, subsequently able to access appropriate care. PMID:27648440

  2. Endoscopic Ultrasound Guided Fine Needle Aspiration Biopsy in Diagnosis of Pancreatic and Peripancreatic Lesions: A Single Center Experience in Korea

    PubMed Central

    Hwang, Chang Yun; Song, Tae Jun; Moon, Sung-Hoon; Lee, Don; Park, Do Hyun; Seo, Dong Wan; Lee, Sung Koo; Kim, Myung-Hwan

    2009-01-01

    Background/Aims Although endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports about its performance. The aim of this study was to assess the utility of EUS-FNA without on-site cytopathologist in establishing the diagnosis of solid pancreatic and peripancreatic masses from a single institution in Korea. Methods Medical records of 139 patients who underwent EUS-FNA for pancreatic and peripancreatic solid mass in the year 2007, were retrospectively reviewed. By comparing cytopathologic diagnosis of FNA with final diagnosis, sensitivity, specificity, and accuracy were determined, and factors influencing the accuracy as well as complications were analyzed. Results One hundred twenty out of 139 cases had final diagnosis of malignancy. Sensitivity, specificity, and accuracy of EUS-FNA were 82%, 89%, and 83%, respectively, and positive and negative predictive values were 100% and 46%, respectively. As for factors influencing the accuracy of FNA, lesion size was marginally significant (p-value 0.08) by multivariate analysis. Conclusions EUS-FNA performed without on-site cytopathologist was found to be accurate and safe, and thus EUS-FNA should be a part of the standard management algorithm for pancreatic and peripancreatic mass. PMID:20431733

  3. Cytopathologist-performed and ultrasound-guided fine needle aspiration cytology enhances diagnostic accuracy and avoids pitfalls: An overview of 20 years of personal experience with a selection of didactic cases.

    PubMed

    Paksoy, Nadir; Ozbek, Busra

    2018-01-01

    Over the last few decades, fine needle aspiration cytology (FNA) has emerged as a SAFE (Simple, Accurate, Fast, Economical) diagnostic tool based on the morphologic evaluation of cells. The first and most important step in obtaining accurate results from FNA is to procure sufficient and representative material from the lesion and to appropriately transfer this material to the laboratory. Unfortunately, the most important aspect of this task occurs beyond the control of the cytopathologist, a key reason for obtaining unsatisfactory results with FNA. There is growing interest in the field of cytology in "cytopathologist-performed ultrasound (US)-guided FNA," which has been reported to yield accurate results. The first author has been applying FNA in his own private cytopathology practice with a radiologist and under the guidance of US for more than 20 years. This study retrospectively reviews the utility of this practice. We present a selection of didactic examples under different headings that highlight the application of FNA by a cytopathologist, accompanied by US, under the guidance of a radiologist, in the form of an "outpatient FNA clinic." The use of this technique enhances diagnostic accuracy and prevents pitfalls. The highlights of each case are also outlined as "take-home messages."

  4. Perivascular Epithelioid Cell Tumor (PEComa) of Pancreas Diagnosed Preoperatively by Endoscopic Ultrasound-Guided Fine-Needle Aspiration: A Case Report and Review of Literature.

    PubMed

    Collins, Katrina; Buckley, Tinera; Anderson, Kevin; Karasik, Michael; Ligato, Saverio

    2017-01-01

    Perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare mesenchymal tumors and to our knowledge, only 17 cases have been reported in the English literature to date. We report our experience with a new case of primary pancreatic PEComa diagnosed preoperatively by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) complemented by tissue cell block and immunohistochemistry. The patient was a 54-year-old female whose chief complaint was intermittent severe right upper quadrant abdominal pain. Computed-tomography (CT) imaging revealed a mass between the head and the body of the pancreas. EUS-FNA smear preparation was obtained but was nondiagnostic. However, examination of the tissue cell block showed sheets of epithelioid cells with abundant eosinophilic cytoplasm and immunohistochemistry studies revealed positivity for both melanocytic (HMB-45 and Melan-A) and smooth muscle markers (actin and desmin). A diagnosis of PEComa was made and an uncomplicated middle pancreatectomy was performed. Our case and review of the literature demonstrates that EUS-FNA complemented with tissue cell block increases cellular yield, improved preoperative diagnostic accuracy, and may assist the surgeon in planning conservative surgical management. Diagn. Cytopathol. 2017;45:59-65. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Endoscopic ultrasound-guided fine-needle aspiration with liquid-based cytologic preparation in the diagnosis of primary pancreatic lymphoma.

    PubMed

    Rossi, Esther Diana; Larghi, Alberto; Verna, Elizabeth C; Martini, Maurizio; Galasso, Domenico; Carnuccio, Antonella; Larocca, Luigi Maria; Costamagna, Guido; Fadda, Guido

    2010-11-01

    The diagnosis subtyping of lymphoma on specimens collected by endoscopic ultrasound fine-needle aspiration (EUS-FNA) can be extremely difficult. When a cytopathologist is available for the on-site evaluation, the diagnosis may be achieved by applying flow cytometric techniques. We describe our experience with immunocytochemistry (ICC) and molecular biology studies applied on EUS-FNA specimens processed with a liquid-based cytologic (LBC) preparation for the diagnosis of primary pancreatic lymphoma (PPL). Three patients with a pancreatic mass underwent EUS-FNA. The collected specimens were processed with the ThinPrep method for the cytologic diagnosis and eventual additional investigations. A morphologic picture consistent with PPL was found on the LBC specimens of the 3 patients. Subsequent ICC and molecular biology studies for immunoglobulin heavy chain gene rearrangement established the diagnosis of pancreatic large B-cell non-Hodgkin lymphoma in 2 patients and a non-Hodgkin lymphoma with plasmoblastic/immunoblastic differentiation in the remaining one. An LBC preparation can be used to diagnose and subtype PPL by applying ICC and molecular biology techniques to specimens collected with EUS-FNA. This method can be an additional processing method for EUS-FNA specimens in centers where on-site cytopathologist expertise is not available.

  6. Learning, techniques, and complications of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline.

    PubMed

    Polkowski, M; Larghi, A; Weynand, B; Boustière, C; Giovannini, M; Pujol, B; Dumonceau, J-M

    2012-02-01

    This article is the second of a two-part publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided Trucut biopsy. The first part (the Clinical Guideline) focused on the results obtained with EUS-guided sampling, and the role of this technique in patient management, and made recommendations on circumstances that warrant its use. The current Technical Guideline discusses issues related to learning, techniques, and complications of EUS-guided sampling, and to processing of specimens. Technical issues related to maximizing the diagnostic yield (e.g., rapid on-site cytopathological evaluation, needle diameter, microcore isolation for histopathological examination, and adequate number of needle passes) are discussed and recommendations are made for various settings, including solid and cystic pancreatic lesions, submucosal tumors, and lymph nodes. The target readership for the Clinical Guideline mostly includes gastroenterologists, oncologists, internists, and surgeons while the Technical Guideline should be most useful to endoscopists who perform EUS-guided sampling. A two-page executive summary of evidence statements and recommendations is provided. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Evolution of a rapid onsite evaluation (ROSE) service for endobronchial ultrasound guided (EBUS) fine needle aspiration (FNA) cytology in a UK Hospital: A 7 year audit.

    PubMed

    Stevenson, Tracey; Powari, Manish; Bowles, Christopher

    2018-05-13

    Endobronchial ultrasound fine needle aspiration (EBUS FNA) is a well-established procedure for the diagnosis and staging of lung cancer. We review our provision of this service at the Royal Devon and Exeter NHS Foundation Trust and the role of rapid onsite evaluation (ROSE) with the increasing demand for molecular markers in this era of personalized medicine. A review of the changes in the Endoscopy clinic over the 7 years from the introduction of EBUS at the end of 2010 until 2017 was carried out. This included the availability of material obtained for diagnosis, accurate subtyping, and molecular testing. We also assessed the success of molecular genetics DNA techniques from EBUS material versus formalin fixed paraffin embedded tissue (FFPE). A total of 1218 EBUS cases with ROSE were reported between 2011 and 2017 Percentage diagnostic rates were calculated as 83, 82, 84, 92, 93, 94, and 92 for 2011, 2012, 2013, 2014, 2015, 2016, and 2017, respectively. Availability of material for immunocytochemistry ranged from 86 to 100% over the 7 years. Molecular testing was successfully performed for EGFR in 89-100% of requested cases and ALK testing in 87-100% of requested cases. EBUS sourced material gave on average twice the amount of DNA and fewer amplicon repeats per patient compared to FFPE material. ROSE at EBUS FNA provides access to suitable material for molecular testing with increased yields in the form of needle washings for EGFR with FFPE materials for ALK and PDL1 testing. © 2018 Wiley Periodicals, Inc.

  8. Benefits of Ultrasound Imaging for Placement of Caudal Epidural Blockade in 3 Pediatric Patients: A Case Report.

    PubMed

    Sinskey, Jina L; Vecchione, Tricia M; Ekstrom, Benjamin G; Boretsky, Karen

    2018-06-01

    Pediatric caudal epidural blockade, the most common pediatric regional anesthetic, is classically placed using surface landmark technique with infrequent use of ultrasound guidance. We present 3 cases where ultrasound guidance facilitated successful placement and helped prevent complications. One infant had an unanticipated S5 dural sac necessitating needle redirection to avoid subarachnoid injection. A 5-year old had proper needle position with inability to inject secondary to needle blockage confirmed with ultrasound. An expremature infant had initial needle placement anterior to the sacrum with subsequent proper placement using real-time ultrasound imaging. Ultrasound guidance for pediatric caudal placement confers advantages and increased routine use should be considered.

  9. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less

  10. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2018-06-01

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  11. A Randomized Double-Blinded Trial on the Effects of Ultrasound Transducer Orientation on Teaching and Learning Ultrasound-Guided Regional Anesthesia.

    PubMed

    Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R

    2016-07-01

    Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.

  12. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiu Wu; Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8; Yuchi Ming

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped;more » the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions: The proposed needle segmentation algorithm is accurate, robust, and suitable for 3D TRUS guided prostate transperineal therapy.« less

  13. THE RESULTS OF PARATHYROID HORMONE ASSAY IN PARATHYROID ASPIRATES IN PRE-OPERATIVE LOCALIZATION OF PARATHYROID ADENOMAS FOR FOCUSED PARATHYROIDECTOMY IN PATIENTS WITH NEGATIVE OR SUSPICIOUS TECHNETIUM-99M-SESTAMIBI SCANS.

    PubMed

    Ozderya, Aysenur; Temizkan, Sule; Cetin, Kenan; Ozugur, Sule; Gul, Aylin Ege; Aydin, Kadriye

    2017-09-01

    This study aimed to evaluate the results of parathyroid hormone (PTH) assay in parathyroid aspirates to determine uniglandular disease by an endocrinologist-performed ultrasound (US) in patients with discordant or negative technetium-sestamibi scans and to evaluate whether this procedure increases the number of focused parathyroidectomies (FPs). We analyzed the data of 65 patients who underwent an endocrinologist-performed US-guided parathyroid fine-needle aspiration (FNA) with PTH wash-out, retrospectively. The results of PTH wash-out procedure and the reports of parathyroid surgery and pathology were reviewed. Of 65 patients, 54 had positive PTH wash-out results. The median serum PTH level of patients with positive and negative PTH wash-out results was 143 (25 and 75% interquartile range [IQR], 114 to 197) versus 154 (IQR, 115 to 255) pg/mL (P = .45), and the median PTH in FNA was 3,533 (IQR, 1,481 to 3,534) versus 6.0 (IQR, 1 to 6) pg/mL (P<.001), respectively. Forty-five patients underwent surgery. Of the operated patients, 42 had positive PTH wash-out results and had successful FP. Four patients with redo surgery had positive PTH wash-out results and were successfully re-operated with FP. Of 11 patients with negative PTH wash-out results, 3 had bilateral neck exploration (BNE) surgery and 2 patients were successfully operated, while surgery was unsuccessful in 1 patient, despite BNE. Our study results suggest that endocrinologist-performed US and parathyroid FNA with PTH wash-out increases the number and success of FPs. In particular, patients with redo surgery may benefit from this procedure. 4D-CT = four-dimensional computed tomography BNE = bilateral neck exploration FNA = fine-needle aspiration FNAB = fine-needle aspiration biopsy FP = focused parathyroidectomy IQR = 25 and 75% inter-quartile range PHPT = primary hyperparathyroidism PPV = positive predictive value PTH = parathyroid hormone 99m Tc = technetium US = ultrasound.

  14. Lung cancer diagnosis and staging with endobronchial ultrasound-guided transbronchial needle aspiration compared with conventional approaches: an open-label, pragmatic, randomised controlled trial

    PubMed Central

    Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M

    2015-01-01

    Summary Background The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. Methods In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Findings Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14–15) than with CDS (29 days; 23–35) resulting in a hazard ratio of 1·98, (1·39–2·82, p<0·0001). One patient in each group had a pneumothorax from a CT-guided biopsy sample; the patient from the CDS group needed intercostal drainage and was admitted to hospital. Interpretation Transbronchial needle aspiration guided by endobronchial ultrasound should be considered as the initial investigation for patients with suspected lung cancer, because it reduces the time to treatment decision compared with conventional diagnosis and staging techniques. Funding UK Medical Research Council. PMID:25660225

  15. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    PubMed

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  16. New platform for evaluating ultrasound-guided interventional technologies

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.

    2016-04-01

    Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.

  17. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  18. Pancreatic fine needle aspiration. A comparison of computed tomographic and endoscopic ultrasonographic guidance.

    PubMed

    Qian, Xiaohua; Hecht, Jonathan L

    2003-01-01

    To compare the sensitivity and specificity of pancreatic fine needle aspiration (FNA) with computed tomography (CT) and endoscopic ultrasound (EUS) guidance. A 6-year retrospective review included 137 pancreatic FNAs (CT 51, magnetic resonance imaging 2 or EUS 84). Clinical or histologic follow-up was available for 110 patients. Positive (POS), suspicious (SUS), atypical, negative and unsatisfactory (UNSAT) results represented 25.5%, 7.3%, 7.3%, 40.1% and 19.1% of reported diagnoses, respectively. In detecting malignancy, the sensitivities of POS/SUS results were 71% and 42% for CT and EUS, respectively, with negative predictive value (NPV) of 41% and 45%. Also, 35% of UNSAT results were found to have malignancy. However, EUS was used on more difficult lesions, including 82% of small, cystic ones and 75% of small, solid ones. Although the apparent performance of percutaneous CT-guided biopsies surpasses that of EUS, this is due to the choice of endoscopy for more difficult lesions. The specificity and negative predictive value of EUS and CT are similar.

  19. Endoscopic Ultrasound-guided Specimen Collection and Evaluation Techniques Affect Diagnostic Accuracy.

    PubMed

    Bang, Ji Young; Navaneethan, Udayakumar; Hasan, Muhammad K; Hawes, Robert; Varadarajulu, Shyam

    2018-03-11

    Outcomes of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) evaluation vary with technique, needles, and methods of specimen evaluation. We performed a direct comparison of diagnostic yields of EUS-FNA samples collected using different gauge needles (22- vs 25-gauge), with or without suction. We performed a randomized controlled study of 352 patients with suspected pancreatic masses, referred for EUS-FNA at a tertiary referral center. Patients were randomly assigned to 22-gauge needles with or without suction or 25-gauge needles with or without suction. Specimens were evaluated offsite by cell block and rapid onsite cytologic evaluation (ROSE). Final diagnoses were made based on histologic analyses or 12-month follow-up evaluations. The primary outcome was diagnostic adequacy of cell blocks. Secondary outcomes were operating characteristics of ROSE and EUS-FNA, number of passes required for accurate onsite diagnosis, and amount of blood in specimens. The final diagnoses were malignancy (81.5% of patients) and benign disease (17.0% of patients); 1.4% of patients were lost during follow up. Cell block, ROSE, and EUS-FNA led to diagnostic accuracies of 71.9%, 95.5%, and 96.6%, respectively. A 22-gauge needle with suction was associated with more passes for adequate onsite diagnosis (P = .003) and specimens contained more blood (P = .01). Diagnostic accuracy of specimens collected by transduodenal EUS-FNA was lower with 22-gauge needles with suction compared to other techniques (P = .004). In a randomized trial of patients undergoing EUS-FNA for pancreatic masses, samples collected with 22-gauge vs 25-gauge needles performed equally well for offsite specimen evaluation. Use of suction appears to increase number of passes needed and specimen bloodiness. Specimen collection techniques should be individualized based on method of evaluation. ClinicalTrials.gov no: NCT02424838. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  20. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no difference between the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy according to the internal composition of the lesions. There were no complications requiring intervention or hospitalization in our patients. Ultrasonography-guided core needle biopsy is superior to ultrasonography-guided fine-needle aspiration in detecting and characterizing malignant tumors of the salivary gland and could emerge as the diagnostic method of choice for patients presenting with a salivary gland mass. © 2015 by American Journal of Neuroradiology.

  1. Endoscopic ultrasound-guided fine needle core biopsy for the diagnosis of pancreatic malignant lesions: a systematic review and Meta-Analysis

    PubMed Central

    Yang, Yongtao; Li, Lianyong; Qu, Changmin; Liang, Shuwen; Zeng, Bolun; Luo, Zhiwen

    2016-01-01

    Endoscopic ultrasound-guided fine needle core biopsy (EUS-FNB) has been used as an effective method of diagnosing pancreatic malignant lesions. It has the advantage of providing well preserved tissue for histologic grading and subsequent molecular biological analysis. In order to estimate the diagnostic accuracy of EUS-FNB for pancreatic malignant lesions, studies assessing EUS-FNB to diagnose solid pancreatic masses were selected via Medline. Sixteen articles published between 2005 and 2015, covering 828 patients, met the inclusion criteria. The summary estimates for EUS-FNB differentiating malignant from benign solid pancreatic masses were: sensitivity 0.84 (95% confidence interval (CI), 0.82–0.87); specificity 0.98 (95% CI, 0.93–1.00); positive likelihood ratio 8.0 (95% CI 4.5–14.4); negative likelihood ratio 0.17 (95% CI 0.10–0.26); and DOR 64 (95% CI 30.4–134.8). The area under the sROC curve was 0.96. Subgroup analysis did not identify other factors that could substantially affect the diagnostic accuracy, such as the study design, location of study, number of centers, location of lesion, whether or not a cytopathologist was present, and so on. EUS-FNB is a reliable diagnostic tool for solid pancreatic masses and should be especially considered for pathology where histologic morphology is preferred for diagnosis. PMID:26960914

  2. Diagnostic Efficacy of Cell Block Immunohistochemistry, Smear Cytology, and Liquid-Based Cytology in Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Lesions: A Single-Institution Experience

    PubMed Central

    Qin, Shan-yu; Zhou, You; Li, Ping; Jiang, Hai-xing

    2014-01-01

    Background The diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) cytology varies widely depending on the treatment method of the specimens. The present study aimed to evaluate the diagnostic efficacy of cell block (CB) immunohistochemistry, smear cytology (SC), and liquid-based cytology (LBC) in patients with pancreatic lesions without consulting an on-site cytopathologist. Methods This study prospectively enrolled 72 patients with pancreatic lesions. The EUS-FNA specimens were examined by SC, LBC, and CB immunohistochemistry. The diagnostic efficacy of the 3 methods was then compared. Patients’ final diagnosis was confirmed by surgical resection specimens, diagnostic imaging, and clinical follow-up. Results Our results included 60 malignant and 12 benign pancreatic lesions. The diagnostic sensitivity (90%), negative predictive value (66.7%), and accuracy (91.7%) of CB immunohistochemistry were significantly higher than those of SC (70.0%, 30.0%, and 75.0%, respectively) and LBC (73.3%, 31.6%, and 77.8%, respectively) (all P<0.05). The combination of CB and SC, or CB and LBC, did not significantly increase the efficacy compared to CB immunohistochemistry alone. Conclusion Our findings suggest that in the absence of an on-site cytopathologist, CB immunohistochemistry on EUS-FNA specimens offers a higher diagnostic efficacy in patients with pancreatic lesions than does SC and LBC. PMID:25259861

  3. Management of cystic or predominantly cystic thyroid nodules: the role of ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Bellantone, Rocco; Lombardi, Celestino Pio; Raffaelli, Marco; Traini, Emanuela; De Crea, Carmela; Rossi, Esther Diana; Fadda, Guido

    2004-01-01

    Conventional fine-needle aspiration biopsy (FNAB) for cystic thyroid nodules (CTNs) has a high rate of nondiagnostic and false-negative results. Ultrasound-guided FNAB (UG-FNAB) permits direct sampling of the wall and/or the solid portion of CTNs, increasing the possibility of a representative sample. In this study we evaluated the role of UG-FNAB in CTNs management. Five-hundred-seventy-five UG-FNAB of CTNs were performed. Thyroidectomy was carried out in 119 of these cases. The medical records of these 119 patients were reviewed and form the basis of this report. The nondiagnostic smear rate was 9.2%. Cytological diagnosis was benign nodule in 42 cases, predominantly follicular lesion in 50 cases, and suspicious or malignant lesion in 16 cases. The final pathology revealed a benign nodule in 98 cases (82.4%) and a carcinoma in 21 (17.6%). The overall accuracy of UG-FNAB was 88.0%. No significant differences were found in age, sex, lesion size, or echographic pattern (p = NS) comparing patients with benign CTNs to patients with malignant CTNs. UG-FNAB has a low rate of nondiagnostic smears and a high overall accuracy in CTNs. All CTNs should undergo UG-FNAB to select patients for surgery, since the malignancy rate is not negligible and no clinical parameter can reliably predict it.

  4. Endoscopic ultrasound guided brush/fine-needle aspiration cytology: A 15-month study.

    PubMed

    Tummidi, Santosh; Kothari, Kanchan; Sathe, Pragati; Agnihotri, Mona; Fernandes, Gwendolyn; Naik, Leena; Jain, Aleena; Chaturvedi, Rachana

    2018-06-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has become increasingly popular for the diagnosis and staging of gastrointestinal diseases and peri-gastrointestinal lesions. The application of FNA/Brush has dramatically expanded the clinical utility of EUS. To evaluate the diagnostic accuracy, study the spectrum of lesions encountered in EUS-FNAC/brush cytology of gastrointestinal and peri-gastrointestinal lesions. Total of 124 patients during the period from August 2015 to November 2016 was included in the study. Routine staining was done. A total of 124 cases were studied with 86% (107 cases) being satisfactory for evaluation. M:F ratio was 1:1.03, mean age of 50.5 years. The most common site was common bile duct (CBD) (37%) followed by lymph node (21%), pancreas (17.7%), esophagus (17%), stomach (3.5%), liver (1.8%), gallbladder (1%), and spleen (1%). In total, 53.4% lesions were benign, in 6.5% atypical cells were seen, 12.1% were suspicious for malignancy, and 28% cases were positive for malignancy. Follow-up was available in 102 cases with cyto-histopathological concordance rate of 90%. EUS-FNA/Brush is a reliable, sensitive, specific and minimally invasive way to establish a diagnosis. It can be utilized as a pre-operative procedure for the management of many intra-abdominal lesions and prevent unnecessary invasive procedures. © 2018 Wiley Periodicals, Inc.

  5. Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods

    PubMed Central

    Tadic, Mario; Stoos-Veic, Tajana; Kusec, Rajko

    2014-01-01

    The role of endoscopic ultrasound (EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration (FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA (EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition (needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy. PMID:25339816

  6. The Clinical Usefulness of Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy for Rectal and Perirectal Lesions

    PubMed Central

    Soh, Jae Seung; Lee, Ho-Su; Lee, Seohyun; Bae, Jungho; Lee, Hyo Jeong; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho

    2015-01-01

    Background/Aims Endoscopic ultrasound-guided fine needle aspiration and/or biopsy (EUS-FNA/B) have been used to diagnose subepithelial tumors (SETs) and extraluminal lesions in the gastrointestinal tract. Our group previously reported the usefulness of EUS-FNA/B for rectal and perirectal lesions. This study reports our expanded experience with EUS-FNA/B for rectal and perirectal lesions in terms of diagnostic accuracy and safety. We also included our new experience with EUS-FNB using the recently introduced ProCore needle. Methods From April 2009 to March 2014, EUS-FNA/B for rectal and perirectal lesions was performed in 30 consecutive patients. We evaluated EUS-FNA/B performance by comparing histological diagnoses with final results. We also investigated factors affecting diagnostic accuracy. Results Among 10 patients with SETs, EUS-FNA/B specimen results revealed a gastrointestinal stromal tumor in 4 patients and malignant lymphoma in 1 patient. The diagnostic accuracy of EUS-FNA/B was 50% for SETs (5/10). Among 20 patients with non-SET lesions, 8 patients were diagnosed with malignant disease and 7 were diagnosed with benign disease based on both EUS-FNA/B and the final results. The diagnostic accuracy of EUS-FNA/B for non-SET lesions was 75% (15/20). The size of lesions was the only factor related to diagnostic accuracy (P=0.027). Two complications of mild fever and asymptomatic pneumoperitoneum occurred after EUS-FNA/B. Conclusions The overall diagnostic accuracy of EUS-FNA/B for rectal and perirectal lesions was 67% (20/30). EUS-FNA/B is a clinically useful method for cytological and histological diagnoses of rectal and perirectal lesions. PMID:25931998

  7. Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.

    PubMed

    Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S

    2014-07-01

    (1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  8. Endoscopic ultrasound-guided techniques for diagnosing pancreatic mass lesions: Can we do better?

    PubMed Central

    Storm, Andrew C; Lee, Linda S

    2016-01-01

    The diagnostic approach to a possible pancreatic mass lesion relies first upon various non-invasive imaging modalities, including computed tomography, ultrasound, and magnetic resonance imaging techniques. Once a suspect lesion has been identified, tissue acquisition for characterization of the lesion is often paramount in developing an individualized therapeutic approach. Given the high prevalence and mortality associated with pancreatic cancer, an ideal approach to diagnosing pancreatic mass lesions would be safe, highly sensitive, and reproducible across various practice settings. Tools, in addition to radiologic imaging, currently employed in the initial evaluation of a patient with a pancreatic mass lesion include serum tumor markers, endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA). EUS-FNA has grown to become the gold standard in tissue diagnosis of pancreatic lesions. PMID:27818584

  9. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    PubMed

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  10. Ultrasonography in Acupuncture-Uses in Education and Research.

    PubMed

    Leow, Mabel Qi He; Cui, Shu Li; Mohamed Shah, Mohammad Taufik Bin; Cao, Taige; Tay, Shian Chao; Tay, Peter Kay Chai; Ooi, Chin Chin

    2017-06-01

    This study aims to explore the potential use of ultrasound in locating the second posterior sacral foramen acupuncture point, quantifying depth of insertion and describing surrounding anatomical structures. We performed acupuncture needle insertion on a study team member. There were four steps in our experiment. First, the acupuncturist located the acupuncture point by palpation. Second, we used an ultrasound machine to visualize the structures surrounding the location of the acupuncture point and measure the depth required for needle insertion. Third, the acupuncturist inserted the acupuncture needle into the acupuncture point at an angle of 30°. Fourth, we performed another ultrasound scan to ensure that the needle was in the desired location. Results suggested that ultrasound could be used to locate the acupuncture point and estimate the depth of needle insertion. The needle was inserted to a depth of 4.0 cm to reach the surface of the sacral foramen. Based on Pythagoras theorem, taking a needle insertion angle of 30° and a needle insertion depth of 4.0 cm, the estimated perpendicular depth is 1.8 cm. An ultrasound scan corroborated the depth of 1.85 cm. The use of an ultrasound-guided technique for needle insertion in acupuncture practice could help standardize the treatment. Clinicians and students would be able to visualize and measure the depth of the sacral foramen acupuncture point, to guide the depth of needle insertion. This methodological guide could also be used to create a standard treatment protocol for research. A similar mathematical guide could also be created for other acupuncture points in future. Copyright © 2017. Published by Elsevier B.V.

  11. Automatic needle segmentation in 3D ultrasound images using 3D improved Hough transform

    NASA Astrophysics Data System (ADS)

    Zhou, Hua; Qiu, Wu; Ding, Mingyue; Zhang, Songgen

    2008-03-01

    3D ultrasound (US) is a new technology that can be used for a variety of diagnostic applications, such as obstetrical, vascular, and urological imaging, and has been explored greatly potential in the applications of image-guided surgery and therapy. Uterine adenoma and uterine bleeding are the two most prevalent diseases in Chinese woman, and a minimally invasive ablation system using a needle-like RF button electrode is widely used to destroy tumor cells or stop bleeding. To avoid accidents or death of the patient by inaccurate localizations of the electrode and the tumor position during treatment, 3D US guidance system was developed. In this paper, a new automated technique, the 3D Improved Hough Transform (3DIHT) algorithm, which is potentially fast, accurate, and robust to provide needle segmentation in 3D US image for use of 3D US imaging guidance, was presented. Based on the coarse-fine search strategy and a four parameter representation of lines in 3D space, 3DIHT algorithm can segment needles quickly, accurately and robustly. The technique was evaluated using the 3D US images acquired by scanning a water phantom. The segmentation position deviation of the line was less than 2mm and angular deviation was much less than 2°. The average computational time measured on a Pentium IV 2.80GHz PC computer with a 381×381×250 image was less than 2s.

  12. Endoscopic ultrasound cytologic brushing vs endoscopic ultrasound: fine needle aspiration for cytological diagnosis of cystic pancreatic lesions. A multicenter, randomized open-label trial.

    PubMed

    Lariño-Noia, José; de la Iglesia, Daniel; Iglesias-García, Julio; Macías, Manuel; López Martín, Aurelio; Legaz, María Luisa; Vila, Juan; Reyes, Antonio; Abdulkader, Ihab; Domínguez-Muñoz, J Enrique

    2018-04-24

    the incidence of cystic pancreatic lesions (CPL) in the asymptomatic population is increasing. Achieving a preoperative diagnosis of CPL still remains a challenge. to evaluate the diagnostic accuracy of the cytological diagnosis of CPL from samples obtained by cytology brush versus standard endoscopic ultrasound fine needle aspiration (EUS-FNA). a multicenter, randomized, open-label trial was performed of EUS-cytology brush (EUS-EB) versus EUS-FNA for the cytological diagnosis of CPL. Patients that underwent EUS-FNA with a CPL > 15 mm were included and randomized into two groups: group I, EUS-EB; group II, EUS-FNA. The final diagnosis was based on the histological evaluation of surgical specimens and clinical parameters, imaging and a five year follow-up in non-operated patients. The main outcome was the diagnostic accuracy of both methods. Secondary outcomes were the diagnostic adequacy of specimens and the rate of adverse events. Data were compared using the Chi-squared test. An intention to treat (ITT) and per-protocol (PP) analysis were performed. sixty-five patients were included in the study, 31 in group I and 34 in group II. Three patients initially randomized to group I were changed to group II as it was impossible to obtain a sample using the brush. The mean size of the CPL was 28.2 mm (range 16-60 mm). The diagnostic accuracy of EUS-EB was not superior to EUS-FNA, neither in the ITT nor the PP analysis (44.8% vs 41.1%, p = 0.77 and 38.4% vs 45.9%, p = 0.55). EUS-EB does not improve the diagnostic accuracy of CPL in comparison with EUS-FNA.

  13. Use of High Frequency Ultrasound to Monitor Cervical Lymph Node Alterations in Mice

    PubMed Central

    Walk, Elyse L.; McLaughlin, Sarah; Coad, James; Weed, Scott A.

    2014-01-01

    Cervical lymph node evaluation by clinical ultrasound is a non-invasive procedure used in diagnosing nodal status, and when combined with fine-needle aspiration cytology (FNAC), provides an effective method to assess nodal pathologies. Development of high-frequency ultrasound (HF US) allows real-time monitoring of lymph node alterations in animal models. While HF US is frequently used in animal models of tumor biology, use of HF US for studying cervical lymph nodes alterations associated with murine models of head and neck cancer, or any other model of lymphadenopathy, is lacking. Here we utilize HF US to monitor cervical lymph nodes changes in mice following exposure to the oral cancer-inducing carcinogen 4-nitroquinoline-1-oxide (4-NQO) and in mice with systemic autoimmunity. 4-NQO induces tumors within the mouse oral cavity as early as 19 wks that recapitulate HNSCC. Monitoring of cervical (mandibular) lymph nodes by gray scale and power Doppler sonography revealed changes in lymph node size eight weeks after 4-NQO treatment, prior to tumor formation. 4-NQO causes changes in cervical node blood flow resulting from oral tumor progression. Histological evaluation indicated that the early 4-NQO induced changes in lymph node volume were due to specific hyperproliferation of T-cell enriched zones in the paracortex. We also show that HF US can be used to perform image-guided fine needle aspirate (FNA) biopsies on mice with enlarged mandibular lymph nodes due to genetic mutation of Fas ligand (Fasl). Collectively these studies indicate that HF US is an effective technique for the non-invasive study of cervical lymph node alterations in live mouse models of oral cancer and other mouse models containing cervical lymphadenopathy. PMID:24955984

  14. Use of high frequency ultrasound to monitor cervical lymph node alterations in mice.

    PubMed

    Walk, Elyse L; McLaughlin, Sarah; Coad, James; Weed, Scott A

    2014-01-01

    Cervical lymph node evaluation by clinical ultrasound is a non-invasive procedure used in diagnosing nodal status, and when combined with fine-needle aspiration cytology (FNAC), provides an effective method to assess nodal pathologies. Development of high-frequency ultrasound (HF US) allows real-time monitoring of lymph node alterations in animal models. While HF US is frequently used in animal models of tumor biology, use of HF US for studying cervical lymph nodes alterations associated with murine models of head and neck cancer, or any other model of lymphadenopathy, is lacking. Here we utilize HF US to monitor cervical lymph nodes changes in mice following exposure to the oral cancer-inducing carcinogen 4-nitroquinoline-1-oxide (4-NQO) and in mice with systemic autoimmunity. 4-NQO induces tumors within the mouse oral cavity as early as 19 wks that recapitulate HNSCC. Monitoring of cervical (mandibular) lymph nodes by gray scale and power Doppler sonography revealed changes in lymph node size eight weeks after 4-NQO treatment, prior to tumor formation. 4-NQO causes changes in cervical node blood flow resulting from oral tumor progression. Histological evaluation indicated that the early 4-NQO induced changes in lymph node volume were due to specific hyperproliferation of T-cell enriched zones in the paracortex. We also show that HF US can be used to perform image-guided fine needle aspirate (FNA) biopsies on mice with enlarged mandibular lymph nodes due to genetic mutation of Fas ligand (Fasl). Collectively these studies indicate that HF US is an effective technique for the non-invasive study of cervical lymph node alterations in live mouse models of oral cancer and other mouse models containing cervical lymphadenopathy.

  15. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia

    2012-08-15

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.« less

  17. Electromyographic Comparison of Forearm Muscle Movements for Fine Skin Suturing Between an Enlarged Pen Needle Holder and a Webster Needle Holder

    PubMed Central

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    Background: For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. Methods: A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. Results: The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Conclusions: Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting. PMID:23691259

  18. Electromyographic comparison of forearm muscle movements for fine skin suturing between an enlarged pen needle holder and a webster needle holder.

    PubMed

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting.

  19. Short beveled sharp cutting needle is superior to facet tip needle for ultrasound-guided rectus sheath block in children with umbilical hernia: a case series.

    PubMed

    Alsaeed, A; Thallaj, A; Alzahrani, T; Khalil, N; Aljazaeri, A

    2014-10-01

    The most common peripheral nerve blocks used in umbilical hernia repair are rectus sheath block and regional block (caudal block). Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this study is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery, and to evaluate the easiness of soft tissue puncture and ultrasonic appearance of two different needle types. Twenty two (22) pediatric patients (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz linear probe. An ultrasound-guided rectus sheath block in the lateral edge of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). A 22 gauge short beveled sharp cutting needle 1.1 x 30 mm needle A (BD Insyte--W, Vialon material. Spain) was used in one side, and a Stimuplex A insulated Needle 22G 50mm (needle B) was used on the other side. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia were evaluated. Ultrasonograghic visualization of the posterior sheath was possible in all patients. Needle A scored 72.7% of excellent needle tip and shaft view (16 out of 22) compared to 63.63% for needle B (14 out of 22). None of the needles scored poor view. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one child who postoperatively requested morphine 0.1 mg/kg intravenously in recovery room. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia in the lateral edge of the rectus muscle. Use of the sharp short beveled needle of 22 gauge intravenous (IV) cannula stylet provides easy, less traumatic skin and rectus muscle penetration and better needle visualization by the ultrasound.

  20. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    PubMed

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  1. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    NASA Astrophysics Data System (ADS)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and ultrasound enhanced (echogenic) needle.

  2. The sensitivity of motor response to needle nerve stimulation during ultrasound guided interscalene catheter placement.

    PubMed

    Fredrickson, Michael J

    2008-01-01

    Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of

  3. Simulation and training of ultrasound supported anaesthesia: a low-cost approach

    NASA Astrophysics Data System (ADS)

    Schaaf, T.; Lamontain, M.; Hilpert, J.; Schilling, F.; Tolxdorff, T.

    2010-03-01

    The use of ultrasound imaging technology during techniques of peripheral nerve blockade offers several clinical benefits. Here we report on a new method to educate residents in ultrasound-guided regional anesthesia. The daily challenge for the anesthesiologists is the 3D angle-depending handling of the stimulation needle and the ultrasound probe while watching the 2D ultrasound image on the monitor. Purpose: Our approach describes how a computer-aided simulation and training set for ultrasound-guided regional anesthesia could be built based on wireless low-cost devices and an interactive simulation of a 2D ultrasound image. For training purposes the injection needle and the ultrasound probe are replaced by wireless Bluetooth-connected 3D tracking devices, which are embedded in WII-mote controllers (Nintendo-Brand). In correlation to the tracked 3D positions of the needle and transducer models the visibility and position of the needle should be simulated in the 2D generated ultrasound image. Conclusion: In future, this tracking and visualization software module could be integrated in a more complex training set, where complex injection paths could be trained based on a 3D segmented model and the training results could be part of a curricular e-learning module.

  4. Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy.

    PubMed

    Kuang, Y; Hilgers, A; Sadiq, M; Cochran, S; Corner, G; Huang, Z

    2016-07-01

    Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Simplified stereo-optical ultrasound plane calibration

    NASA Astrophysics Data System (ADS)

    Hoßbach, Martin; Noll, Matthias; Wesarg, Stefan

    2013-03-01

    Image guided therapy is a natural concept and commonly used in medicine. In anesthesia, a common task is the injection of an anesthetic close to a nerve under freehand ultrasound guidance. Several guidance systems exist using electromagnetic tracking of the ultrasound probe as well as the needle, providing the physician with a precise projection of the needle into the ultrasound image. This, however, requires additional expensive devices. We suggest using optical tracking with miniature cameras attached to a 2D ultrasound probe to achieve a higher acceptance among physicians. The purpose of this paper is to present an intuitive method to calibrate freehand ultrasound needle guidance systems employing a rigid stereo camera system. State of the art methods are based on a complex series of error prone coordinate system transformations which makes them susceptible to error accumulation. By reducing the amount of calibration steps to a single calibration procedure we provide a calibration method that is equivalent, yet not prone to error accumulation. It requires a linear calibration object and is validated on three datasets utilizing di erent calibration objects: a 6mm metal bar and a 1:25mm biopsy needle were used for experiments. Compared to existing calibration methods for freehand ultrasound needle guidance systems, we are able to achieve higher accuracy results while additionally reducing the overall calibration complexity. Ke

  6. Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.

    PubMed

    Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N

    2015-01-01

    The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.

  7. Electrolytic echo enhancement: a novel method to make needles more reflective to ultrasound.

    PubMed

    Cockburn, John F; Khosh, Stefan K

    2014-04-01

    This study examines the effect of augmenting the ultrasound reflectivity of needles using a novel electrolytic echo enhancement method. Needles were connected by a lead to the negative terminal of a 4.5 V direct current source. A grounding pad, connected to the positive terminal, was positioned on the undersurface of an ex vivo ox liver phantom. During needle insertion into the liver, electrolysis was induced creating a layer of gas on the needle electrode. Analysis of images showed a significant increase in needle brightness using electrolytic echo enhancement. Brightness was found to increase by a factor of ×3.6 compared with controls (P < 0.001). Electrolytic echo enhancement has the potential to make ultrasound-guided procedures safer and quicker for patients and increase the confidence of operators in their ability to see the whole needle including its tip. © 2014 The Royal Australian and New Zealand College of Radiologists.

  8. Percutaneous transhepatic cholangiographic endobiliary forceps biopsy versus endoscopic ultrasound fine needle aspiration for proximal biliary strictures: a single-centre experience.

    PubMed

    Mohkam, Kayvan; Malik, Yaseen; Derosas, Carlos; Isaac, John; Marudanayagam, Ravi; Mehrzad, Homoyoon; Mirza, Darius F; Muiesan, Paolo; Roberts, Keith J; Sutcliffe, Robert P

    2017-06-01

    Endoscopic ultrasound fine needle aspiration (EUS-FNA) and percutaneous transhepatic cholangiographic endobiliary forceps biopsy (PTC-EFB) are valid procedures for histological assessment of proximal biliary strictures (PBS), but their performances have never been compared. This study aimed to compare the diagnostic performance of these two techniques. The diagnostic performances of EUS-FNA and PTC-EFB were compared in a retrospective cohort of patients assessed for PBS from 2011 to 2015 at a single tertiary centre. An inverse probability of treatment weighting (IPTW) was performed to adjust for covariate imbalance. A total of 102 EUS-FNAs and 75 PTC-EFBs (performed in 137 patients) were compared. Patients in the PTC-EFB group had higher preoperative bilirubin (243 versus 169 μmol/l, p = 0.005) and a higher incidence of malignancy (87% versus 67%, p = 0.008). Both techniques showed specificity and positive predictive value of 100%, and similar sensitivity (69% versus 75%, p = 0.45), negative predictive value (58% versus 38%, p = 0.15) and accuracy (78% versus 79%, p = 1.00). After IPTW, the diagnostic performance of the two techniques remained similar. Compared to EUS-FNA, PTC-EFB provides similar sensitivity, negative predictive value and accuracy. It should therefore be considered as the preferred tissue-sampling procedure, if biliary drainage is indicated. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  9. Videothoracoscopy in the treatment of mediastinal cysts

    PubMed Central

    Brzeziński, Daniel; Kozak, Józef

    2014-01-01

    Introduction Progress in the development of surgical techniques has led to the growing use of video-assisted thoracoscopic surgery (VATS) techniques in mediastinal cyst treatment. Aim To present our experience of treating mediastinal cysts with the minimally invasive technique. Material and methods Fifty patients with mediastinal cysts were treated from 2001 to 2011. There were 32 women and 18 men. The age of the patients ranged from 17 to 72, the mean age being 42 years. All patients underwent basic preoperative diagnostic tests of the chest: X-ray, computed tomography (CT), bronchoscopy and spirometry; 4 patients underwent endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and 3 fine needle aspiration biopsy (FNAB) of the described lesions. Results The VATS was performed in each case. Conversion was carried out due to superior mediastinal location in 10 cases and pleural adhesions in 3 cases. The partial resection of a cyst was performed in 3 patients. One patient was treated conservatively due to heart failure. In that patient the transthoracic needle aspiration of a cyst under ultrasound guidance using alcoholisation with 76% ethanol with a good effect was performed twice. Cyst recurrence was observed in 1 case. Conclusions The surgical access depends on the location of a cyst. The VATS resection of a superior mediastinal cyst is not always feasible. Surgery of mediastinal cysts is both diagnostic and curative. PMID:25337163

  10. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    PubMed Central

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  11. Targeted Next Generation Sequencing with ThyroSeq v2.1 for Indeterminate Thyroid Nodules in Clinical Practice.

    PubMed

    Witt, Robert L

    2016-12-01

    To determine if patients elect molecular testing over diagnostic surgery or repeat fine needle aspiration for indeterminate thyroid nodules. Can ThyroSeq v2.1 molecular testing reduce diagnostic thyroid surgery and rule out cancer? Retrospective review Setting: Single institution, single-practice surgeon. Fifteen month retrospective review of indeterminate thyroid nodules that went on to ThyroSeq v2.1 testing. 286 patients met American Thyroid Association guideline criteria for surgeon- performed, ultrasound-guided fine needle aspiration for a thyroid nodule with on-site cytopathology. The indeterminate (Bethesda III or IV) fine needle aspiration cytology rate was 9.1 percent. Prevalence of malignancy in indeterminate nodules was 19 percent. 26/26 (100 percent) patients with indeterminate thyroid nodules elected molecular testing. 16 patients had no mutation, 9 had one or more mutations, and I had no result. 16 of 25 (64 percent) patients with no mutation elected not to undergo diagnostic surgery for indeterminate thyroid nodules. Patients demonstrated a strong preference for molecular testing instead of diagnostic thyroid surgery for indeterminate thyroid nodules. All patients in this series, 25/25 (100 percent) with indeterminate thyroid nodules elected molecular testing instead of repeat biopsy or diagnostic thyroid surgery. 16 of 25 (64 percent) patients tested had no mutation. All 16/16 (100 percent) patients with no mutation on ThyroSeq "rule out" testing elected active surveillance rather than surgery or biopsy, reducing diagnostic surgery. The risk of malignancy among mutation negative patients was not definitively established. There are a number of factors currently that may mute the power of "rule in" testing.

  12. Silk suture reaction in thyroid surgery

    PubMed Central

    Soylu, Selen; Teksoz, Serkan; Ozcan, Murat; Bukey, Yusuf

    2017-01-01

    Silk suture reaction (i.e., a benign granulomatous inflammatory foreign body reaction) is a rare complication of thyroid surgery. Here, two cases of post-thyroidectomy suture reaction are presented. Both of the patients were female, one is 48 and the other is 34 years old. The patients were presented with neck swelling and leakage of serous fluid from the Kocher’s incision. Both patients had normal free T4, free T3, and TSH values. The 48-year-old female patient had a right subtotal and left near-total thyroidectomy 6 years ago and the other had bilateral total thyroidectomy 6 years ago. In the physical examination a mobile, painless, red, swelling was palpated in front of neck. In the ultrasound of both patients, a heterogeneous nodule with hypoechoic rim was seen, however, in scintigraphy no radiopharmaceutical involvement was observed in thyroid region. Due to suspicion of thyroid malignancy, a fine needle aspiration biopsy was performed and foreign body reaction was revealed cytologically. A suture reaction can vary from an erythematous swelling to chronic granulomatous reaction. The time interval between the operation and formation of suture reaction was 6 years in both of the cases thus these patients were considered as chronic patients. Foreign body reaction diagnosis was confirmed with fine needle aspiration biopsy. It is important to diagnose these chronic inflammation cases since these cases can mimic recurrence in thyroid malignancies. A post-thyroidectomy suture reaction is diagnosed cytologically with fine needle aspiration biopsy and by surgical removal of suture, this chronic inflammatory reaction can be cured. PMID:29142853

  13. Benchmarking of state-of-the-art needle detection algorithms in 3D ultrasound data volumes

    NASA Astrophysics Data System (ADS)

    Pourtaherian, Arash; Zinger, Svitlana; de With, Peter H. N.; Korsten, Hendrikus H. M.; Mihajlovic, Nenad

    2015-03-01

    Ultrasound-guided needle interventions are widely practiced in medical diagnostics and therapy, i.e. for biopsy guidance, regional anesthesia or for brachytherapy. Needle guidance using 2D ultrasound can be very challenging due to the poor needle visibility and the limited field of view. Since 3D ultrasound transducers are becoming more widely used, needle guidance can be improved and simplified with appropriate computer-aided analyses. In this paper, we compare two state-of-the-art 3D needle detection techniques: a technique based on line filtering from literature and a system employing Gabor transformation. Both algorithms utilize supervised classification to pre-select candidate needle voxels in the volume and then fit a model of the needle on the selected voxels. The major differences between the two approaches are in extracting the feature vectors for classification and selecting the criterion for fitting. We evaluate the performance of the two techniques using manually-annotated ground truth in several ex-vivo situations of different complexities, containing three different needle types with various insertion angles. This extensive evaluation provides better understanding on the limitations and advantages of each technique under different acquisition conditions, which is leading to the development of improved techniques for more reliable and accurate localization. Benchmarking results that the Gabor features are better capable of distinguishing the needle voxels in all datasets. Moreover, it is shown that the complete processing chain of the Gabor-based method outperforms the line filtering in accuracy and stability of the detection results.

  14. Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.

    PubMed

    Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs

    2012-08-01

    Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.

  15. Real-time needle guidance with photoacoustic and laser-generated ultrasound probes

    NASA Astrophysics Data System (ADS)

    Colchester, Richard J.; Mosse, Charles A.; Nikitichev, Daniil I.; Zhang, Edward Z.; West, Simeon; Beard, Paul C.; Papakonstantinou, Ioannis; Desjardins, Adrien E.

    2015-03-01

    Detection of tissue structures such as nerves and blood vessels is of critical importance during many needle-based minimally invasive procedures. For instance, unintentional injections into arteries can lead to strokes or cardiotoxicity during interventional pain management procedures that involve injections in the vicinity of nerves. Reliable detection with current external imaging systems remains elusive. Optical generation and reception of ultrasound allow for depth-resolved sensing and they can be performed with optical fibers that are positioned within needles used in clinical practice. The needle probe developed in this study comprised separate optical fibers for generating and receiving ultrasound. Photoacoustic generation of ultrasound was performed on the distal end face of an optical fiber by coating it with an optically absorbing material. Ultrasound reception was performed using a high-finesse Fabry-Pérot cavity. The sensor data was displayed as an M-mode image with a real-time interface. Imaging was performed on a biological tissue phantom.

  16. Real-time image-based B-mode ultrasound image simulation of needles using tensor-product interpolation.

    PubMed

    Zhu, Mengchen; Salcudean, Septimiu E

    2011-07-01

    In this paper, we propose an interpolation-based method for simulating rigid needles in B-mode ultrasound images in real time. We parameterize the needle B-mode image as a function of needle position and orientation. We collect needle images under various spatial configurations in a water-tank using a needle guidance robot. Then we use multidimensional tensor-product interpolation to simulate images of needles with arbitrary poses and positions using collected images. After further processing, the interpolated needle and seed images are superimposed on top of phantom or tissue image backgrounds. The similarity between the simulated and the real images is measured using a correlation metric. A comparison is also performed with in vivo images obtained during prostate brachytherapy. Our results, carried out for both the convex (transverse plane) and linear (sagittal/para-sagittal plane) arrays of a trans-rectal transducer indicate that our interpolation method produces good results while requiring modest computing resources. The needle simulation method we present can be extended to the simulation of ultrasound images of other wire-like objects. In particular, we have shown that the proposed approach can be used to simulate brachytherapy seeds.

  17. Modeling, Production, and Testing of an Echogenic Needle for Ultrasound-Guided Nerve Blocks.

    PubMed

    Bigeleisen, Paul E; Hess, Aaron; Zhu, Richard; Krediet, Annelot

    2016-06-01

    We have designed, produced, and tested an echogenic needle based on a sawtooth pattern where the height of the tooth was 1.25 times the wavelength of the ultrasound transducer. A numeric solution to the time-independent wave equation (Helmholtz equation) was used to create a model of backscattering from a needle. A 21-gauge stainless steel prototype was manufactured and tested in a water bath. Backscattering from the needle was compared to theoretical predications from our model. Based on these results, an 18-gauge prototype needle was fabricated from stainless steel and tested in a pig cadaver. This needle was compared to a commercial 18-gauge echogenic needle (Pajunk Medical Systems, Tucker, GA) by measuring the brightness of the needle relative to the background of sonograms of a needle in a pig cadaver. The backscattering from the 21-gauge prototype needle reproduced the qualitative predictions of our model. At 30° and 45° of insonation, our prototype performed equivalently to the Pajunk needle. At 60°, our prototype was significantly brighter than the Pajunk needle (P = .017). In conclusion, we chose a model for the design of an echogenic needle and modeled it on the basis of a solution to the Helmholtz equation. A prototype needle was tested in a water bath and compared to the model prediction. After verification of our model, we designed an 18-gauge needle, which performed better than an existing echogenic needle (Pajunk) at 60° of insonation. Our needle will require further testing in human trials. © 2016 by the American Institute of Ultrasound in Medicine.

  18. Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images

    PubMed Central

    Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600

  19. A preliminary result of three-dimensional microarray technology to gene analysis with endoscopic ultrasound-guided fine-needle aspiration specimens and pancreatic juices

    PubMed Central

    2010-01-01

    Background Analysis of gene expression and gene mutation may add information to be different from ordinary pathological tissue diagnosis. Since samples obtained endoscopically are very small, it is desired that more sensitive technology is developed for gene analysis. We investigated whether gene expression and gene mutation analysis by newly developed ultra-sensitive three-dimensional (3D) microarray is possible using small amount samples from endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) specimens and pancreatic juices. Methods Small amount samples from 17 EUS-FNA specimens and 16 pancreatic juices were obtained. After nucleic acid extraction, the samples were amplified with labeling and analyzed by the 3D microarray. Results The analyzable rate with the microarray was 46% (6/13) in EUS-FNA specimens of RNAlater® storage, and RNA degradations were observed in all the samples of frozen storage. In pancreatic juices, the analyzable rate was 67% (4/6) in frozen storage samples and 20% (2/10) in RNAlater® storage. EUS-FNA specimens were classified into cancer and non-cancer by gene expression analysis and K-ras codon 12 mutations were also detected using the 3D microarray. Conclusions Gene analysis from small amount samples obtained endoscopically was possible by newly developed 3D microarray technology. High quality RNA from EUS-FNA samples were obtained and remained in good condition only using RNA stabilizer. In contrast, high quality RNA from pancreatic juice samples were obtained only in frozen storage without RNA stabilizer. PMID:20416107

  20. Orbito-nasal cyst in a young European short-haired cat.

    PubMed

    Zemljič, Tadej; Matheis, Franziska L; Venzin, Claudio; Makara, Mariano; Grest, Paula; Spiess, Bernhard M; Pot, Simon A

    2011-09-01

    To describe a case of an orbito-nasal cyst in a cat. An 18-month-old male European short-haired cat was presented to the Ophthalmology service of the Vetsuisse Faculty, University of Zurich for a subcutaneous swelling in the medial canthal region of the right eye (OD). Ophthalmologic, ultrasound and CT examinations, and fine needle aspiration were performed. After lesion excision, the removed tissue was submitted for histopathology. CT examination was repeated 5 months after removal of the cyst. Ophthalmologic examination revealed a large fluctuant swelling inferonasal to OD. Despite patent lacrimal puncta, only the first few mm of the lacrimal canaliculi could be cannulated. A normal globe with moderate enophthalmos was present. Ultrasound examination showed a well-defined lobulated cyst-like structure in the right orbit, inferonasal and anterior to the eye. CT examination revealed extension of this lesion through the medial orbital wall into the right nasal cavity. Fine needle aspiration confirmed the cystic nature of the lesion. An orbito-nasal cyst was diagnosed. The orbital part of the cyst was dissected from the surrounding tissue and excised from the periosteum in the medial orbital wall defect. Part of the maxillary bone was removed to allow removal of the cyst from the nasal cavity. Histologically, the cyst wall consisted of a single to multilayered, mostly cuboidal epithelium and surrounding connective tissue. Follow-up revealed a good functional result and no recurrence 7 months after cyst removal. Similar orbito-nasal cystic structures were reported in dogs but not in cats. © 2011 American College of Veterinary Ophthalmologists.

  1. Endoscopic ultrasound-guided fine needle aspiration cytology diagnosis of solid pseudopapillary tumor of the pancreas: a report of 3 cases.

    PubMed

    Chatzipantelis, Paschalis; Salla, Charitini; Apostolou, George; Christodoulou, Lambrini; Kakiopoulos, George; Patralexis, Charalambos

    2010-01-01

    Solid pseudopapillary tumor of the pancreas (SPTP) is an exceedingly rare pancreatic tumor. We present the clinical, endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) cytologic features and immunohistochemical findings performed on cell blocks of 3 SPTPs. Three females (17-32 years old) were admitted to our hospital due to unexplained episodic abdominal pain. EUS confirmed the presence of a mass in the body and tail of the pancreas (2 cases) and in the head (1 case), with distinct borders and occassional dilation of the peripheral part of the pancreatic duct. EUS-FNA cytology specimens consisted of single cells and aggregates of uniform polyhedral cells, forming branching papillary clusters with delicate fibrovascular cores and nuclear overlapping (2 cases) and glandlike structures (1 case). Variable hyaline, myxoid stromal elements and naked capillaries were also seen. The cells had bland nuclear features, small nucleoli, nuclear grooves in some of them and focally cytoplasmic projections. Mitoses and necrosis were not observed. The immunohistochemistry on cell blocks revealed: vimentin+ (3 cases), CA19.9+ (2 cases), cytokeratin 7+ (focal, intensive, 1 case), synaptophysin+ (1 case), MUC1+ (focal, intensive, 1 case), EMA+ (diffuse weak, 1 case), a1-antitrypsin and a1-antichymotrypsin+ (focal intensive, 2 cases), progesterone+ (1 case), chromogranin-A- (3 cases) and NSE- (3 cases). Cytologic and immunohistochemical findings were strongly suggestive of SPTP. Surgical resection confirmed the diagnosis in all cases. EUS-FNA cytology features and immunohistochemistry provide the diagnosis of SPTP with accuracy.

  2. Thermal ablation of pancreatic cyst with a prototype endoscopic ultrasound capable radiofrequency needle device: A pilot feasibility study

    PubMed Central

    Moris, Maria; Atar, Mustafa; Kadayifci, Abdurrahman; Krishna, Murli; Librero, Ariston; Richie, Eugene; Brugge, William; Wallace, Michael B.

    2017-01-01

    Background and Objectives: Pancreatic cysts are evaluated by endoscopic ultrasound and fine needle aspiration (EUS). The only accepted treatment is pancreatectomy, which is associated with morbidity and mortality. This study evaluated the optimal thermal dosimetry of a novel radiofrequency ablation device using a standard electrosurgical unit in ex vivo cyst models. Methods: A modified EUS 22-gauge monopolar needle prototype with a tip electrode connected to a standard electrosurgical unit (Erbe USA, Marietta, GA, USA) was used to induce a subboiling point temperature. A cyst model was created using 2-cm sections of porcine small intestine ligated and filled with saline. After ablation, the cyst models were prepared for pathological evaluation. The epithelial layers were measured in at least two different sites with a micrometer and compared with the corresponding control sample. Results: Thirty-two cyst models were ablated with maximum temperatures of 50°C, 60°C, 90°C, and 97°C in 8, 11, 11, and 2 cysts, respectively. Longer ablation times were required to induce higher temperatures. A trend in the reduction in thickness of the measured layers was observed after exposure to higher temperatures. A temperature over 50°C was required for the ablation of the muscularis, submucosa, and villi, and over 60°C was required to ablate the mucosal crypts. Conclusions: In a preclinical model, a novel radiofrequency EUS-capable needle connected to a standard electrosurgical unit using standard low-voltage coagulation provided ablation in a temperature-dependent fashion with a threshold of at least 60°C and a safe cyst margin below 97°C. This potentially will allow low-cost, convenient cyst ablation. PMID:28440238

  3. Validation of American Thyroid Association Ultrasound Risk Assessment of Thyroid Nodules Selected for Ultrasound Fine-Needle Aspiration.

    PubMed

    Tang, Alice L; Falciglia, Mercedes; Yang, Huaitao; Mark, Jonathan R; Steward, David L

    2017-08-01

    The aim of this study was to validate the American Thyroid Association (ATA) sonographic risk assessment of thyroid nodules. The ATA sonographic risk assessment was prospectively applied to 206 thyroid nodules selected for ultrasound-guided fine-needle aspiration (US-FNA), and analyzed with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), as well as surgical pathology for the subset undergoing surgical excision. The analysis included 206 thyroid nodules averaging 2.4 cm (range 1-7 cm; standard error of the mean 0.07). Using the ATA US pattern risk assessment, nodules were classified as high (4%), intermediate (31%), low (38%), and very low (26%) risk of malignancy. Nodule size was inversely correlated with sonographic risk assessment, as lower risk nodules were larger on average (p < 0.0001). Malignancy rates determined by cytology/surgical pathology were high 100%, intermediate 11%, low 8%, and very low 2%, which were closely aligned with ATA malignancy risk estimates (high 70-90%, intermediate 10-20%, low 5-10%, and very low 3%). ATA US pattern risk assessment also appropriately predicted the proportion of nodules classified as malignant or suspicious for malignancy through TBSRTC classification-high (77%), intermediate (6%), low (1%), and very low 0%-as well as benign TBSRTC classification-high (0%), intermediate (47%), low (61%), and very low (70%) (p < 0.0001). Malignancy rates of surgically excised, cytologically indeterminate nodules followed ATA sonographic risk stratification (high 100%, intermediate 21%, low 17%, and very low 12%; p = 0.003). This prospective study supports the new ATA sonographic pattern risk assessment for selection of thyroid nodules for US-FNA based upon TBSRTC and surgical pathology results. In the setting of indeterminate cytopathology, nodules categorized as atypia of undetermined significance/follicular lesion of undetermined significance with ATA high-risk sonographic patterns have a high likelihood of being malignant.

  4. Real-Time Ultrasound-Guided Spinal Anaesthesia: A Prospective Observational Study of a New Approach

    PubMed Central

    Conroy, P. H.; Luyet, C.; McCartney, C. J.; McHardy, P. G.

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1–6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83–4.1) demonstrating the feasibility of this technique in routine clinical practice. PMID:23365568

  5. Thyroid nodule management: clinical, ultrasound and cytopathological parameters for predicting malignancy

    PubMed Central

    Maia, Frederico F. R.; Zantut-Wittmann, Denise Engelbrecht

    2012-01-01

    Although fine-needle aspiration cytology is considered to be the reference method for evaluating thyroid nodules, the results are inaccurate in approximately 10-30% of cases. Several studies have attempted to predict the risk of malignancy in thyroid nodules based on age, nodularity, thyrotropin values, thyroid autoimmune disease, hot/cold nodule status, and ultrasound parameters. However, no consensus has been found, and none of these parameters has significantly affected patient management. The management of indeterminate thyroid nodules and re-biopsies of nodules with initially benign cytological results remain important and controversial topics of discussion. The Bethesda cytological system and several studies on the use of molecular markers to predict malignancy from cytological samples of thyroid nodules need further clarification. More in-depth discussions among and continuous education of the specialists involved in treating thyroid disease are necessary to improve the management of these patients. This review aims to examine the clinical, laboratory, ultrasound, and scintigraphic parameters that can be used for thyroid nodule management. PMID:22948464

  6. Estimating needle tip deflection in biological tissue from a single transverse ultrasound image: application to brachytherapy.

    PubMed

    Rossa, Carlos; Sloboda, Ron; Usmani, Nawaid; Tavakoli, Mahdi

    2016-07-01

    This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by virtual helical springs whose stiffness coefficient is found using a pattern search algorithm that only requires the force applied at the needle tip during insertion and the needle deflection measured at an arbitrary insertion depth. Needle tip deflections can then be predicted for different insertion depths. Verification of the proposed method in synthetic and biological tissue shows a deflection estimation error of [Formula: see text]2 mm for images acquired at 35 % or more of the maximum insertion depth, and decreases to 1 mm for images acquired closer to the final insertion depth. We also demonstrate the utility of the model for prostate brachytherapy, where in vivo needle deflection measurements obtained during early stages of insertion are used to predict the needle deflection further along the insertion process. The method can predict needle deflection based on the observation of deflection at a single point. The ultrasound probe can be maintained at the same position during insertion of the needle, which avoids complications of tissue deformation caused by the motion of the ultrasound probe.

  7. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    NASA Astrophysics Data System (ADS)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  8. Toward a comprehensive hybrid physical-virtual reality simulator of peripheral anesthesia with ultrasound and neurostimulator guidance.

    PubMed

    Samosky, Joseph T; Allen, Pete; Boronyak, Steve; Branstetter, Barton; Hein, Steven; Juhas, Mark; Nelson, Douglas A; Orebaugh, Steven; Pinto, Rohan; Smelko, Adam; Thompson, Mitch; Weaver, Robert A

    2011-01-01

    We are developing a simulator of peripheral nerve block utilizing a mixed-reality approach: the combination of a physical model, an MRI-derived virtual model, mechatronics and spatial tracking. Our design uses tangible (physical) interfaces to simulate surface anatomy, haptic feedback during needle insertion, mechatronic display of muscle twitch corresponding to the specific nerve stimulated, and visual and haptic feedback for the injection syringe. The twitch response is calculated incorporating the sensed output of a real neurostimulator. The virtual model is isomorphic with the physical model and is derived from segmented MRI data. This model provides the subsurface anatomy and, combined with electromagnetic tracking of a sham ultrasound probe and a standard nerve block needle, supports simulated ultrasound display and measurement of needle location and proximity to nerves and vessels. The needle tracking and virtual model also support objective performance metrics of needle targeting technique.

  9. Ensuring patient safety when implementing a new diagnostic pathway for thyroid nodules.

    PubMed

    Brimioulle, M; Al-Lami, A; Marzouk, S; Emerson, H; Balfour, A; Dhar, V; Nixon, I J

    2018-05-01

    Introduction The aim of this study was to determine whether ultrasound alone is sufficient to safely exclude malignancy in thyroid nodules in a district general hospital setting, to comply with the latest British Thyroid Association guidelines. Methods This retrospective study investigated the quality of ultrasound reporting and the correlation between ultrasound report and histology for individual thyroid nodules. Cases were selected from the thyroid multidisciplinary meeting and included all patients having undergone surgery for a thyroid malignancy in a one-year period. Results Forty-seven patients were included in the study. Ultrasound reports were reviewed and assessed, in which 21 clinicians were involved; 36% of scans included a summary of whether the nodule(s) overall appeared benign, equivocal, suspicious or malignant; 4% of reports included a U classification; 81% of reports commented on cervical lymph nodes. Ultrasound was compared with histology. The sensitivity of ultrasound in correctly identifying nodules requiring further investigation was of 56% and specificity was 81%. Positive predictive value was 81% and negative predictive value was 56%. Discussion These findings suggest that, in a district general hospital setting without a dedicated head and neck radiologist, using only ultrasound and limiting fine-needle aspiration cytology to identify suspicious nodules may not be safe, as a high number of nodules appearing benign on ultrasound may ultimately prove to be malignant.

  10. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    PubMed

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  11. The value of the repeated examination of BRAF V600E mutation status in diagnostics of papillary thyroid cancer.

    PubMed

    Beiša, Augustas; Beiša, Virgilijus; Stoškus, Mindaugas; Ostanevičiūtė, Elvyra; Griškevičius, Laimonas; Strupas, Kęstutis

    2016-01-01

    Nodular thyroid disease is one of the most frequently diagnosed pathologies of the adult population in iodine-deficient regions. Approximately 30% of thyroid aspirates are classified as nondiagnostic/unsatisfactory or indeterminate. However, patients with indeterminate cytology still undergo surgery. The object of this study was to determine the diagnostic value of re-examining the BRAF V600E mutation in papillary thyroid carcinoma patients. All patients underwent ultrasound guided fine-needle aspiration of a thyroid nodule. They were assigned to one of the four groups (indeterminate or positive for malignant cells) of the Bethesda System for Reporting Thyroid Cytopathology. Genetic investigation of the BRAF V600E mutation was performed for all of the fine-needle aspiration cytology specimens. All of the patients underwent surgery. Subsequently, histological investigation of the removed tissues was performed. Additional analysis of the BRAF V600E mutation from the histology specimen was then performed for the initially BRAF-negative cases. Two hundred and fourteen patients were involved in the study. One hundred and six (49.53%) patients were diagnosed with thyroid cancer. Of these 106 patients, 95 (89.62%) patients were diagnosed with papillary thyroid cancer. The BRAF V600E mutation was positive in 62 (65.26%) and negative in 33 (34.74%) histologically confirmed papillary thyroid cancer cases. After the genetic investigation, a total of 74 (77.89%) papillary thyroid cancer cases were positive for the BRAF V600E mutation and 21 (22.11%) were negative. Repeated examination of the BRAF V600E mutation status in the fine-needle aspiration may potentially increase the sensitivity of papillary thyroid cancer diagnostics.

  12. Split sample comparison of a liquid-based method and conventional smears in thyroid fine needle aspiration.

    PubMed

    Jung, Chan-Kwon; Lee, Ahwon; Jung, Eun-Sun; Choi, Yeong-Jin; Jung, So-Lyung; Lee, Kyo-Young

    2008-01-01

    To compare the efficacy of the SurePath (SP) vs. conventional smears (CS) in fine needle aspiration (FNA) of thyroid gland lesions. A total of 193 FNA cases with thyroid nodules were studied. Samples from ultrasound-guided FNA were split to prepare CS and SP slides. The diagnostic categories of unsatisfactory, benign, atypical and malignant were compared. Galectin-3 immunostaining was performed on SP slides. Some differences were found between the cytomorphology of CS and SP. SP slides showed more increased cellularity and more clustered tissue fragments. On SP slides, nuclear detail and nucleoli were more easily detected and nuclear irregularity was very useful for the diagnosis of papillary carcinoma. SP showed a trend toward a lower proportion of atypical category. The overall sensitivity of FNA in diagnosing thyroid neoplasm was 90.9% for CS and 93.9% for SP. Most lesions (73%) diagnosed as papillary carcinoma after surgery showed positive staining of galectin-3. The SP method showed easy evaluation of cytomorphologic features and consistent specimen quality and appeared to be more useful in diagnosing the suspicious cases. Moreover, it offered the possibility of adjunctive immunocytochemistry on the same sample.

  13. Incidental primary mediastinal choriocarcinoma diagnosed by endobronchial ultrasound-guided fine needle aspiration in a patient presenting with transient ischemic attack and stroke.

    PubMed

    Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer

    2017-08-01

    We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. Lateral orbitotomy for treatment of an orbital abscess in a dog.

    PubMed

    Vallefuoco, R; Molas, C; Moissonnier, P; Chahory, S

    2014-10-01

    A two-year-old Jack Russell terrier was diagnosed with a retrobulbar abscess and orbital cellulitis. The diagnosis was confirmed by ultrasound, magnetic resonance imaging examination and ultrasound-guided fine-needle aspiration. Transoral ventral drainage was attempted but was unsuccessful. The abscess was successfully treated by open drainage through a lateral orbitotomy. Despite the exposure of the orbital structures, the orbital soft tissues healed by second intention without further complications. The open drainage was well tolerated and resulted in immediate reduction of inflammation and pain, allowing a quick recovery. This report describes the diagnosis and, surgical management and the long-term (3 years) follow-up of an unusual case of orbital abscess associated with diffuse periorbital cellulitis successfully treated by open drainage through a lateral orbitotomy. © 2014 British Small Animal Veterinary Association.

  15. Diagnosis of clinical bovine mastitis by fine needle aspiration followed by staining and scanning electron microscopy in a Prototheca zopfii outbreak.

    PubMed

    da Costa, Elizabeth Oliveira; Ribeiro, Márcio Garcia; Ribeiro, Andréa Rentz; Rocha, Noeme Sousa; de Nardi Júnior, Geraldo

    2004-07-01

    Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.

  16. Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles.

    PubMed

    Antonini, Filippo; Fuccio, Lorenzo; Giorgini, Sara; Fabbri, Carlo; Frazzoni, Leonardo; Scarpelli, Marina; Macarri, Giampiero

    2017-08-01

    While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p=0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48h or ≥48h before EUS). No EUS-FNB related complications were recorded. The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  18. Feasibility of Prostate Cancer Diagnosis by Transrectal Photo-acoustic Imaging

    DTIC Science & Technology

    2013-03-01

    prostate. Transrectal ultrasound has been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for...tool currently available for prostate cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the...developing an integrated approach between ultrasound and optical tomography, namely, transrectal ultrasound - guided diffuse optical tomography (TRUS

  19. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia.

    PubMed

    Hocking, Graham; Hebard, Simon; Mitchell, Christopher H

    2011-01-01

    With the growth of ultrasound-guided regional anesthesia, so has the requirement for training tools to practice needle guidance skills and evaluate echogenic needles. Ethically, skills in ultrasound-guided needle placement should be gained in a phantom before performance of nerve blocks on patients in clinical practice. However, phantom technology is varied, and critical evaluation of the images is needed to understand their application to clinical use. Needle visibility depends on the echogenicity of the needle relative to the echogenicity of the tissue adjacent the needle. We demonstrate this point using images of echogenic and nonechogenic needles in 5 different phantoms at both shallow angles (20 degrees) and steep angles (45 degrees). The echogenicity of phantoms varies enormously, and this impacts on how needles are visualized. Water is anechoic, making all needles highly visible, but does not fix the needle to allow practice placement. Gelatin phantoms and Blue Phantoms provide tactile feedback but have very low background echogenicity, which greatly exaggerates needle visibility. This makes skill acquisition easier but can lead to false confidence in regard to clinical ability. Fresh-frozen cadavers retain much of the textural feel of live human tissue and are nearly as echogenic. Similar to clinical practice, this makes needles inserted at steep angles practically invisible, unless they are highly echogenic. This review describes the uses and pitfalls of phantoms that have been described or commercially produced. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine

  20. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  1. Comparison of two different size needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing solid pancreatic lesions

    PubMed Central

    Xu, Mei-Mei; Jia, Hong-Yu; Yan, Li-Li; Li, Shan-Shan; Zheng, Yue

    2017-01-01

    Abstract Background: This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. Methods: We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. Results: Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%–95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%–91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65–28.14) and 0.16 (95% CI, 0.12–0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65–28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12–0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87–18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09–0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. Conclusion: Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS–FNA. PMID:28151856

  2. Three-Dimensional Ultrasound-Guided Real-Time Midline Epidural Needle Placement with Epiguide: A Prospective Feasibility Study.

    PubMed

    Beigi, Parmida; Malenfant, Paul; Rasoulian, Abtin; Rohling, Robert; Dube, Alison; Gunka, Vit

    2017-01-01

    Current 2-D ultrasound technology is unable to perform a midline neuraxial needle insertion under real-time ultrasound guidance using a standard needle and without an assistant. The aim of the work described here was to determine the feasibility of a new technology providing such capability, starting with a study evaluating the selected puncture site. A novel 3-D ultrasound imaging technique was designed using thick-slice rendering in conjunction with a custom needle guide (3DUS + Epiguide). A clinical feasibility study evaluated the ability of 3DUS + Epiguide to identify the epidural needle puncture site for a midline insertion in the lumbar spine. We hypothesized that (i) the puncture site identified by 3DUS + Epiguide was within a 5-mm radius from the site chosen by standard palpation, and (ii) the difference between the two puncture sites was not correlated to the patient characteristics age, weight, height, body mass index and gestational age. The mean (±standard deviation) distances between puncture sites determined by 3DUS + Epiguide and palpation were 3.1 (±1.7) mm and 2.8 (±1.3) mm, for the L2-3 and L3-4 interspaces of 20 patients, respectively. Distances were comparable to intra-observer variability, indicating the potential for a thick-slice rendering of 3-D ultrasound along the Epiguide trajectory to select the puncture site of a midline neuraxial needle insertion. The long-term potential benefits of this system include increased efficiency and use of anesthesia, and a reduction in the frequency and severity of the complications from incorrect needle insertions. Epidural success in the most difficult cases (e.g., the obese) will be the focus of future work. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    PubMed

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. A serious game for learning ultrasound-guided needle placement skills.

    PubMed

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  5. Comparison of Core-Needle Biopsy and Fine-Needle Aspiration for Evaluating Thyroid Incidentalomas Detected by 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: A Propensity Score Analysis.

    PubMed

    Suh, Chong Hyun; Choi, Young Jun; Lee, Jong Jin; Shim, Woo Hyun; Baek, Jung Hwan; Chung, Han Cheol; Shong, Young Kee; Song, Dong Eun; Sung, Tae Yon; Lee, Jeong Hyun

    2017-10-01

    This study used a propensity score analysis to assess the roles of core-needle biopsy (CNB) and fine-needle aspiration (FNA) in the evaluation of thyroid incidentalomas detected on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT). The study population was obtained from a historical cohort who underwent 18 F-FDG PET/CT between October 2008 and September 2015. Patients were included who underwent ultrasound-guided CNB or FNA for incidental focal uptake of 18 F-FDG in the thyroid gland on PET/CT. The primary study outcomes included the inconclusive result rates in the CNB and FNA groups. The secondary outcome measures included the non-diagnostic result rate and the diagnostic performance for neoplasms. Multivariate analysis, propensity score matching, and inverse probability weighting were conducted. A total of 1360 nodules from 1338 patients were included in this study: 859 nodules from 850 patients underwent FNA, and 501 nodules from 488 patients underwent CNB. Compared to FNA, CNB demonstrated a significantly lower inconclusive result rate in the pooled cohort (23.8% vs. 35.4%; p < 0.001), propensity score-matched cohorts (22.9% vs. 36.6%; p < 0.001), and with inverse probability weighting (22.4% vs. 35.2%; p < 0.001). Non-diagnostic result rates were also significantly lower in CNB than in FNA. The diagnostic performance of the two groups in the pooled and matched cohorts was similar, with no significant differences found. The significantly lower inconclusive result rates in CNB than in FNA were consistent within the propensity score-matched cohorts. Therefore, CNB appears to be a promising diagnostic tool for patients with thyroid incidentalomas detected on 18 F-FDG PET/CT.

  6. Utility of shear wave elastography to detect papillary thyroid carcinoma in thyroid nodules: efficacy of the standard deviation elasticity.

    PubMed

    Kim, Hye Jeong; Kwak, Mi Kyung; Choi, In Ho; Jin, So-Young; Park, Hyeong Kyu; Byun, Dong Won; Suh, Kyoil; Yoo, Myung Hi

    2018-02-23

    The aim of this study was to address the role of the elasticity index as a possible predictive marker for detecting papillary thyroid carcinoma (PTC) and quantitatively assess shear wave elastography (SWE) as a tool for differentiating PTC from benign thyroid nodules. One hundred and nineteen patients with thyroid nodules undergoing SWE before ultrasound-guided fine needle aspiration and core needle biopsy were analyzed. The mean (EMean), minimum (EMin), maximum (EMax), and standard deviation (ESD) of SWE elasticity indices were measured. Among 105 nodules, 14 were PTC and 91 were benign. The EMean, EMin, and EMax values were significantly higher in PTCs than benign nodules (EMean 37.4 in PTC vs. 23.7 in benign nodules, p = 0.005; EMin 27.9 vs. 17.8, p = 0.034; EMax 46.7 vs. 31.5, p < 0.001). The EMean, EMin, and EMax were significantly associated with PTC with diagnostic odds ratios varying from 6.74 to 9.91, high specificities (86.4%, 86.4%, and 88.1%, respectively), and positive likelihood ratios (4.21, 3.69, and 4.82, respectively). The ESD values were significantly higher in PTC than in benign nodules (6.3 vs. 2.6, p < 0.001). ESD had the highest specificity (96.6%) when applied with a cut-off value of 6.5 kPa. It had a positive likelihood ratio of 14.75 and a diagnostic odds ratio of 28.50. The shear elasticity index of ESD, with higher likelihood ratios for PTC, will probably identify nodules that have a high potential for malignancy. It may help to identify and select malignant nodules, while reducing unnecessary fine needle aspiration and core needle biopsies of benign nodules.

  7. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    PubMed

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (p<0.001). There was no difference between the AUC of conventional ultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  8. Ultrasound-guided fine-needle aspiration biopsy of clinically suspicious thyroid nodules with an automatic aspirator: a novel technique.

    PubMed

    Nagarajah, James; Sheu-Grabellus, Sien-Yi; Farahati, Jamshid; Kamruddin, Kamer A; Bockisch, Andreas; Schmid, Kurt Werner; Görges, Rainer

    2012-07-01

    Fine-needle aspiration biopsy (FNAB) is a simple technique for the investigation of suspicious thyroid nodules. However, low success rates are reported in the literature. The aim of this prospective study was to compare the clinical performance and impact of an automatic aspirator, referred to here as Aspirator 3, to those of the manual technique for the FNAB of clinically suspicious thyroid nodules. One hundred nine consecutive patients with 121 clinically suspicious thyroid nodules underwent a biopsy twice of the same site with the clinically approved Aspirator 3 and with the manual technique. The number of follicular cell formations and the total number of follicular cells in the aspirate were counted using the ThinPrep® method. With the Aspirator 3, the total number and the mean number of extracted cell formations were significantly higher than the values achieved with the manual technique (total: 3222 vs. 1951, p=0.02; mean: 27 vs. 16). The total number of cells that were biopsied was also higher when the Aspirator 3 was utilized (47,480 vs. 23,080, p=0.005). Overall, the Aspirator 3 was superior in 65 biopsies, and the manual technique was superior in 39 biopsies. In terms of cell formations and the total number of cells aspirated, the Aspirator 3 was superior to the manual technique. Further, the Aspirator 3 was more convenient to use and had a greater precision in needle guidance.

  9. Direct comparison of the diagnostic yield of ultrasound-assisted Abrams and Tru-Cut needle biopsies for pleural tuberculosis.

    PubMed

    Koegelenberg, Coenraad Frederik N; Bolliger, Christoph Thomas; Theron, Johan; Walzl, Gerhard; Wright, Colleen Anne; Louw, Mercia; Diacon, Andreas Henri

    2010-10-01

    Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles. This prospective study compared ultrasound-assisted Abrams and Tru-Cut needle biopsies with regard to their diagnostic yield for pleural tuberculosis. 89 patients (54 men) of mean ± SD age 38.7 ± 16.7 years with pleural effusions and a clinical suspicion of tuberculosis were enrolled in the study. Transthoracic ultrasound was performed on all patients, who were then randomly assigned to undergo ≥ 4 Abrams needle biopsies followed by ≥ 4 Tru-Cut needle biopsies or vice versa. Medical thoracoscopy was performed on cases with non-diagnostic closed biopsies. Histological and/or microbiological proof of tuberculosis on any pleural specimen was considered the gold standard for pleural tuberculosis. Pleural tuberculosis was diagnosed in 66 patients, alternative diagnoses were established in 20 patients and 3 remained undiagnosed. Pleural biopsy specimens obtained with Abrams needles contained pleural tissue in 81 patients (91.0%) and were diagnostic for tuberculosis in 54 patients (sensitivity 81.8%), whereas Tru-Cut needle biopsy specimens only contained pleural tissue in 70 patients (78.7%, p=0.015) and were diagnostic in 43 patients (sensitivity 65.2%, p=0.022). Ultrasound-assisted pleural biopsies performed with an Abrams needle are more likely to contain pleura and have a significantly higher diagnostic sensitivity for pleural tuberculosis.

  10. Needle Biopsy

    MedlinePlus

    ... needle biopsy procedures include fine-needle aspiration and core needle biopsy. Needle biopsy may be used to ... hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses ...

  11. A Randomized Controlled Trial Evaluating the See, Tilt, Align, and Rotate (STAR) Maneuver on Skill Acquisition for Simulated Ultrasound-Guided Interventional Procedures.

    PubMed

    Lam, Nicholas C K; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Gerstein, Neal S; Mariano, Edward R

    2015-06-01

    Achieving the best view of the needle and target anatomy when performing ultrasound-guided interventional procedures requires technical skill, which novices may find difficult to learn. We hypothesized that teaching novice performers to use 4 sequential steps (see, tilt, align, and rotate [STAR] method) to identify the needle under ultrasound guidance is more efficient than training with the commonly described probe movements of align, rotate, and tilt (ART). This study compared 2 instructional methods for transducer manipulation including alignment of a probe and needle by novices during a simulated ultrasound-guided nerve block. Right-handed volunteers between the ages of 18 and 55 years who had no previous ultrasound experience were recruited and randomized to 1 of 2 groups; one group was trained to troubleshoot misalignment with the ART method, and the other was trained with the new STAR maneuver. Participants performed the task, consisting of directing a needle in plane to 3 targets in a standardized gelatin phantom 3 times. The performance assessor and data analyst were blinded to group assignment. Thirty-five participants were recruited. The STAR group was able to complete the task more quickly (P < .001) and visualized the needle in a greater proportion of the procedure time (P = .004) compared to the ART group. All STAR participants were able to complete the task, whereas 41% of ART participants abandoned the task (P = .003). Novices are able to complete a simulated ultrasound-guided nerve block more quickly and efficiently when trained with the 4-step STAR maneuver compared to the ART method. © 2015 by the American Institute of Ultrasound in Medicine.

  12. Toxoplasma lymphadenitis diagnosed by fine-needle aspiration cytology: a rare finding.

    PubMed

    Hosokawa, S; Kusama, Y; Ono, T; Mineta, H

    2014-06-01

    There are only very few reports of cervical toxoplasma lymphadenitis being diagnosed exclusively via fine-needle aspiration cytology (with serology). We describe a case of toxoplasma lymphadenitis that was successfully diagnosed by fine-needle aspiration cytology. The case involved a male patient who was immunocompromised as a result of recurrent acute myelogenous leukaemia with cervical lymphadenopathy. The biopsy showed typical features of a well-defined pseudocyst containing Toxoplasma gondii tachyzoites. Toxoplasma lymphadenitis is a common cause of lymph node enlargement. Fine-needle aspiration cytology is a useful method for diagnosing and differentiating toxoplasma lymphadenitis from more serious causes of lymphadenopathy, such as metastatic lymphadenopathy or lymphoma.

  13. Ultrasound-guided needle EMG of the diaphragm: technique description and case report.

    PubMed

    Boon, Andrea J; Alsharif, Kais I; Harper, C Michel; Smith, Jay

    2008-12-01

    We describe an ultrasound (US)-guided technique for needle examination of the diaphragm and report a case in which the adjuvant use of diagnostic US in conjunction with electrophysiologic studies provided additional information regarding the motion of the diaphragm in a patient who was a potential candidate for phrenic nerve pacing. US imaging provides excellent direct and real-time visualization of soft tissue, anatomic landmarks, fascial planes, and neurovascular structures. It thereby enhances safety by avoiding accidental needle puncture of vital organs, and it also increases the diagnostic utility of the needle examination.

  14. Evaluating the Minimal Specimens From Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Pancreatic Masses

    PubMed Central

    Park, Joo Kyung; Kang, Ki Joo; Oh, Cho Rong; Lee, Jong Kyun; Lee, Kyu Taek; Jang, Kee Taek; Park, Sang-Mo; Lee, Kwang Hyuck

    2016-01-01

    Abstract Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has become one of the most useful diagnostic modalities for the diagnosis of pancreatic mass. The aim of this study was to investigate the role of analyzing the minimal specimens obtained by EUS-FNA for the diagnosis of solid masses of pancreas. This study consisted of retrospective and prospective analyses. The retrospective study was performed on 116 patients who underwent EUS-FNA of solid masses for cytological smear, histological analysis, and combined analysis including immunohistochemical (IHC) staining. In the prospective study, 79 patients were enrolled to evaluate the quality and accuracy of EUS-FNA histological analysis and feasibility of IHC staining. The final diagnoses of all patients included pancreatic cancer (n = 126), nonpancreatic cancer (n = 21), other neoplasm (n = 27), and benign lesions (n = 21). In our retrospective study, the combined analysis was more sensitive than cytological analysis alone (P < 0.01). The overall sensitivity of cytology, histology, and combined analysis was 69.8%, 67.2%, and 81.8%, respectively. In the prospective analysis, 64.2% of all punctures were helpful for determining the diagnosis and 40.7% provided sufficient tissue for IHC staining. Histological analysis was helpful for diagnosis in 74.7% of patients. IHC staining was necessary for a definite diagnosis in 11.4% of patients, especially in the cases of nonmalignant pancreatic mass. Histological analysis and IHC study of EUS-FNA specimens was useful for the accurate diagnosis of pancreatic and peripancreatic lesions. Combined analysis showed significantly higher sensitivity than cytology alone because IHC staining was helpful for a diagnosis in some patients. PMID:27227937

  15. MicroRNAs for Detection of Pancreatic Neoplasia

    PubMed Central

    Vila-Navarro, Elena; Vila-Casadesús, Maria; Moreira, Leticia; Duran-Sanchon, Saray; Sinha, Rupal; Ginés, Àngels; Fernández-Esparrach, Glòria; Miquel, Rosa; Cuatrecasas, Miriam; Castells, Antoni; Lozano, Juan José; Gironella, Meritxell

    2017-01-01

    Objective: The aim of our study was to analyze the miRNome of pancreatic ductal adenocarcinoma (PDAC) and its preneoplastic lesion intraductal papillary mucinous neoplasm (IPMN), to find new microRNA (miRNA)-based biomarkers for early detection of pancreatic neoplasia. Objective: Effective early detection methods for PDAC are needed. miRNAs are good biomarker candidates. Methods: Pancreatic tissues (n = 165) were obtained from patients with PDAC, IPMN, or from control individuals (C), from Hospital Clínic of Barcelona. Biomarker discovery was done using next-generation sequencing in a discovery set of 18 surgical samples (11 PDAC, 4 IPMN, 3 C). MiRNA validation was carried out by quantitative reverse transcriptase PCR in 2 different set of samples. Set 1—52 surgical samples (24 PDAC, 7 IPMN, 6 chronic pancreatitis, 15 C), and set 2—95 endoscopic ultrasound-guided fine-needle aspirations (60 PDAC, 9 IPMN, 26 C). Results: In all, 607 and 396 miRNAs were significantly deregulated in PDAC and IPMN versus C. Of them, 40 miRNAs commonly overexpressed in both PDAC and IPMN were selected for further validation. Among them, significant up-regulation of 31 and 30 miRNAs was confirmed by quantitative reverse transcriptase PCR in samples from set 1 and set 2, respectively. Conclusions: miRNome analysis shows that PDAC and IPMN have differential miRNA profiles with respect to C, with a large number of deregulated miRNAs shared by both neoplastic lesions. Indeed, we have identified and validated 30 miRNAs whose expression is significantly increased in PDAC and IPMN lesions. The feasibility of detecting these miRNAs in endoscopic ultrasound-guided fine-needle aspiration samples makes them good biomarker candidates for early detection of pancreatic cancer. PMID:27232245

  16. Sensitivity, Specificity, and Posttest Probability of Parotid Fine-Needle Aspiration: A Systematic Review and Meta-analysis.

    PubMed

    Liu, C Carrie; Jethwa, Ashok R; Khariwala, Samir S; Johnson, Jonas; Shin, Jennifer J

    2016-01-01

    (1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of nondiagnostic and indeterminate cytology with parotid FNA. Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I(2) statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I(2) point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509-0.982) and a specificity of 0.995 (95% CI, 0.960-0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030-0.075) and 0.147 (95% CI, 0.106-0.188), respectively. FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.

  17. Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings

    PubMed Central

    Lee, Mi-Jung; Hong, Soon Won; Chung, Woung Youn; Kwak, Jin Young; Kim, Min Jung

    2011-01-01

    Purpose To compare the cytological results of ultrasound-guided fine-needle aspiration (US-FNA) cytology of thyroid nodules to sonographic findings and determine whether US findings are helpful in the interpretation of cytological results. Materials and Methods Among the thyroid nodules that underwent US-FNA cytology, we included the 819 nodules which had a conclusive diagnosis. Final diagnosis was based on pathology from surgery, repeated FNA cytology or follow-up of more than one year. Cytological results were divided into five groups: benign, indeterminate (follicular or Hurthle cell neoplasm), suspicious for malignancy, malignant, and inadequate. US findings were categorized as benign or suspicious. Cytological results and US categories were analyzed. Results Final diagnosis was concluded upon in 819 nodules based on pathology (n=311), repeated FNA cytology (n=204) and follow-up (n=304), of which 634 were benign and 185 were malignant. There were 560 benign nodules, 141 malignant nodules, 49 nodules with inadequate results, 21 with indeterminate results, and 48 that were suspicious for malignancy. The positive and negative predictive values of the US categories were 59.1% and 97.0%, and those of the cytological results were 93.7% and 98.9%. The US categories were significantly correlated with final diagnosis in the benign (p=0.014) and suspicious for malignancy (p<0.001) cytological result groups, but not in the inadequate and indeterminate cytological results groups. The false positive and negative rates of cytological results were 1.9% and 3.2%. Conclusion Sonographic findings can be useful when used alongside cytological results, especially in nodules with cytological results that are benign or suspicious for malignancy. PMID:21786450

  18. Sensitivity, Specificity, and Posttest Probability of Parotid Fine-Needle Aspiration: A Systematic Review and Meta-analysis

    PubMed Central

    Liu, C. Carrie; Jethwa, Ashok R.; Khariwala, Samir S.; Johnson, Jonas; Shin, Jennifer J.

    2016-01-01

    Objectives (1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of non-diagnostic and indeterminate cytology with parotid FNA. Data Sources Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Review Methods Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I2 statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. Results The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I2 point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509–0.982) and a specificity of 0.995 (95% CI, 0.960–0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030–0.075) and 0.147 (95% CI, 0.106–0.188), respectively. Conclusion FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. PMID:26428476

  19. Clinical utility of routine pre-operative axillary ultrasound and fine needle aspiration cytology in patient selection for sentinel lymph node biopsy.

    PubMed

    Rattay, T; Muttalib, M; Khalifa, E; Duncan, A; Parker, S J

    2012-04-01

    In patients with operable breast cancer, pre-operative evaluation of the axilla may be of use in the selection of appropriate axillary surgery. Pre-operative axillary ultrasound (US) and fine needle aspiration cytology (FNAC) assessments have become routine practice in many breast units, although the evidence base is still gathering. This study assessed the clinical utility of US+/-FNAC in patient selection for either axillary node clearance (ANC) or sentinel lymph node biopsy (SLNB) in patients undergoing surgery for operable breast cancer. Over a two-year period, 348 patients with a clinically negative axilla underwent axillary US. 67 patients with suspicious nodes on US also underwent FNAC. The sensitivity and specificity of axillary investigations to determine nodal involvement were 56% (confidence interval: 47-64%) and 90% (84-93%) for US alone, and 76% (61-87%) and 100% (65-100%) for FNAC combined with US, respectively. With a positive US, the post-test probability was 78%. A negative US carried a post-test probability of 25%. When FNAC was positive, the post-test probability was greater than unity. A negative FNAC yielded a post-test probability of 52%. All patients with positive FNAC and most patients with suspicious US were listed for axillary node clearance (ANC) after consideration at the multi-disciplinary team (MDT) meeting. With pre-operative axillary US+/-FNAC, 20% of patients were saved a potential second axillary procedure, facilitating a reduction in the overall re-operation rate to 12%. In this study, a positive pre-operative US+/-FNAC directs patients towards ANC. When the result is negative, other clinico-pathological factors need to be taken into account in the selection of the appropriate axillary procedure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  1. Integration of single-fiber reflectance spectroscopy into ultrasound-guided endoscopic lung cancer staging of mediastinal lymph nodes

    NASA Astrophysics Data System (ADS)

    Kanick, Stephen Chad; van der Leest, Cor; Aerts, Joachim G. J. V.; Hoogsteden, Henk C.; Kaščáková, Slávka; Sterenborg, Henricus J. C. M.; Amelink, Arjen

    2010-01-01

    We describe the incorporation of a single-fiber reflectance spectroscopy probe into the endoscopic ultrasound fine-needle aspiration (EUS-FNA) procedure utilized for lung cancer staging. A mathematical model is developed to extract information about the physiological and morphological properties of lymph tissue from single-fiber reflectance spectra, e.g., microvascular saturation, blood volume fraction, bilirubin concentration, average vessel diameter, and Mie slope. Model analysis of data from a clinical pilot study shows that the single-fiber reflectance measurement is capable of detecting differences in the physiology between normal and metastatic lymph nodes. Moreover, the clinical data show that probe manipulation within the lymph node can perturb the in vivo environment, a concern that must be carefully considered when developing a sampling strategy. The data show the feasibility of this novel technique; however, the potential clinical utility has yet to be determined.

  2. Painless thyroiditis associated to thyroid carcinoma: role of initial ultrasonography evaluation.

    PubMed

    Valentini, Raisa Bressan; Macedo, Bruno Mussoi de; Izquierdo, Rogério Friedrich; Meyer, Erika Laurini Souza

    2016-04-01

    Even though it is a rare event, most associations of thyroid carcinoma with subacute thyroiditis described in the literature are related to its granulomatous form (Quervain's thyroiditis). We present a patient with subacute lymphocytic thyroiditis (painless thyroiditis) and papillary thyroid cancer that was first suspected in an initial ultrasound evaluation. A 30-year old female patient who was referred to the emergency room due to hyperthyroidism symptoms was diagnosed with painless thyroiditis established by physical examination and laboratory findings. With the presence of a palpable painless thyroid nodule an ultrasound was prescribed and the images revealed a suspicious thyroid nodule, microcalcification focus in the heterogeneous thyroid parenquima and cervical lymphadenopathy. Fine needle aspiration biopsy was taken from this nodule; cytology was assessed for compatibility with papillary thyroid carcinoma. Postsurgical pathology evaluation showed a multicentric papillary carcinoma and lymphocytic infiltration. Subacute thyroiditis, regardless of type, may produce transitory ultrasound changes that obscure the coexistence of papillary carcinoma. Due to this, initial thyroid ultrasound evaluation should be delayed until clinical recovery. We recommended a thyroid ultrasound exam for initial evaluation of painless thyroiditis, particularly in patients with palpable thyroid nodule. Further cytological examination is recommended in cases presenting with suspect thyroid nodule and/or non-nodular hypoechoic (> 1 cm) or heterogeneous areas with microcalcification focus.

  3. In vivo photoacoustic and ultrasonic mapping of rat sentinel lymph nodes with a modified commercial ultrasound imaging system

    NASA Astrophysics Data System (ADS)

    Erpelding, Todd N.; Kim, Chulhong; Pramanik, Manojit; Guo, Zijian; Dean, John; Jankovic, Ladislav; Maslov, Konstantin; Wang, Lihong V.

    2010-02-01

    Sentinel lymph node biopsy (SLNB) has become the standard method for axillary staging in breast cancer patients, relying on invasive identification of sentinel lymph nodes (SLNs) following injection of blue dye and radioactive tracers. While SLNB achieves a low false negative rate (5-10%), it is an invasive procedure requiring ionizing radiation. As an alternative to SLNB, ultrasound-guided fine needle aspiration biopsy has been tested clinically. However, ultrasound alone is unable to accurately identify which lymph nodes are sentinel. Therefore, a non-ionizing and noninvasive detection method for accurate SLN mapping is needed. In this study, we successfully imaged methylene blue dye accumulation in vivo in rat axillary lymph nodes using a Phillips iU22 ultrasound imaging system adapted for photoacoustic imaging with an Nd:YAG pumped, tunable dye laser. Photoacoustic images of rat SLNs clearly identify methylene blue dye accumulation within minutes following intradermal dye injection and co-registered photoacoustic/ultrasound images illustrate lymph node position relative to surrounding anatomy. To investigate clinical translation, the imaging depth was extended up to 2.5 cm by adding chicken breast tissue on top of the rat skin surface. These results raise confidence that photoacoustic imaging can be used clinically for accurate, noninvasive SLN mapping.

  4. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  5. Demonstration of an algorithm to overcome health system-related barriers to timely diagnosis of breast diseases in rural Zambia

    PubMed Central

    Nzayisenga, Jean-Baptiste; Shibemba, Aaron; Kusweje, Victor; Chiboola, Hector; Amuyunzu-Nyamongo, Mary; Kapambwe, Sharon; Mwaba, Catherine; Lermontov, Pavlo; Mumba, Chibamba; Henry-Tillman, Ronda; Parham, Groesbeck P.

    2018-01-01

    Background Long delays to diagnosis is a major cause of late presentation of breast diseases in sub-Saharan Africa. Aims We designed and implemented a single-visit breast care algorithm that overcomes health system-related barriers to timely diagnosis of breast diseases. Methods A multidisciplinary team of Zambian healthcare experts trained a team of mid- and high-level Zambian healthcare practitioners how to evaluate women for breast diseases, and train trainers to do likewise. Working collaboratively, the two teams then designed a clinical platform that provides multiple breast care services within a single visit. The service platform was implemented using a breast outreach camp format, during which breast self-awareness, psychosocial counseling, clinical breast examination, breast ultrasound, ultrasound-guided biopsy, imprint cytology of biopsy specimens and surgical treatment or referral, were offered within a single visit. Results Eleven hundred and twenty-nine (1129) women attended the camps for breast care. Mean age was 35.9 years. The majority were multiparous (79.4%), breast-fed (76.0%), and reported hormone use (50.4%). Abnormalities were detected on clinical breast examination in 122 (10.8%) women, 114 of whom required ultrasound. Of the 114 who underwent ultrasound, 48 had identifiable lesions and were evaluated with ultrasound-guided core needle biopsy (39) or fine-needle aspiration (9). The concordance between imprint cytology and histopathology was 100%, when breast specimens were classified as either benign or malignant. However, when specimens were classified by histopathologic subtype, the concordance between imprint cytology and histology was 85.7% for benign and 100% for malignant lesions. Six (6) women were diagnosed with invasive cancer. Eighteen (18) women with symptomatic breast lesions had next-day surgery. Significance Similar to its impact on cervical cancer prevention services, a single visit breast care algorithm has the potential to overcome health system-related barriers to timely diagnosis of breast diseases, including cancer, in rural African settings. PMID:29746541

  6. 360-degree 3D transvaginal ultrasound system for high-dose-rate interstitial gynaecological brachytherapy needle guidance

    NASA Astrophysics Data System (ADS)

    Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron

    2017-03-01

    Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.

  7. Needle Steering in Biological Tissue using Ultrasound-based Online Curvature Estimation

    PubMed Central

    Moreira, Pedro; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2014-01-01

    Percutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes. Accurate placement of the needle tip is important to the success of many needle procedures. The current needle steering systems depend on needle-tissue-specific data, such as maximum curvature, that is unavailable prior to an interventional procedure. In this paper, we present a novel three-dimensional adaptive steering method for flexible bevel-tipped needles that is capable of performing accurate tip placement without previous knowledge about needle curvature. The method steers the needle by integrating duty-cycled needle steering, online curvature estimation, ultrasound-based needle tracking, and sampling-based motion planning. The needle curvature estimation is performed online and used to adapt the path and duty cycling. We evaluated the method using experiments in a homogenous gelatin phantom, a two-layer gelatin phantom, and a biological tissue phantom composed of a gelatin layer and in vitro chicken tissue. In all experiments, virtual obstacles and targets move in order to represent the disturbances that might occur due to tissue deformation and physiological processes. The average targeting error using our new adaptive method is 40% lower than using the conventional non-adaptive duty-cycled needle steering method. PMID:26229729

  8. Differences in accuracy and underestimation rates for 14- versus 16-gauge core needle biopsies in ultrasound-detectable breast lesions.

    PubMed

    Lai, Hung-Wen; Wu, Hwa-Koon; Kuo, Shou-Jen; Chen, Shou-Tung; Tseng, Hsin-Shun; Tseng, Ling-Ming; Chen, Dar-Ren

    2013-04-01

    Core needle biopsy (CNB) was widely used in the diagnosis of ultrasound-detectable breast lesions. We aimed at assessing the diagnostic performance differences between 14- and 16-gauge ultrasound-guided core biopsies. This retrospective study enrolled patients receiving CNB from January 2001 to December 2007. The results of 14- and 16-gauge breast CNBs were compared with pathology reports of open surgical biopsy (OSB). A total of 1024 paired CNB and OSB results were obtained from 1732 CNB procedures in 1630 patients.Those CNB results reached 92.9% sensitivity, 99.7% specificity, 5.96% underestimation, and 94.8% accuracy rates. There was no difference in sensitivity (p=0.17) or specificity (p=0.38) between 14- and 16-gauge needles. However, better overall accuracy (p=0.02), less underestimation (p<0.001), and lower false-negative (p=0.02) rates were found for the 14-gauge CNB. Regarding accuracy and underestimation rates, a 14-gauge needle is preferred to a 16-gauge one in ultrasound-guided biopsies. Copyright © 2012. Published by Elsevier B.V.

  9. Endobronchial ultrasound-guided transbronchial needle injection for local control of recurrent non-small cell lung cancer.

    PubMed

    Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.

  10. A new needle on the block: EchoTip ProCore endobronchial ultrasound needle

    PubMed Central

    Dincer, H Erhan; Andrade, Rafael; Zamora, Felix; Podgaetz, Eitan

    2016-01-01

    Endobronchial ultrasound has become the first choice standard of care procedure to diagnose benign or malignant lesions involving mediastinum and lung parenchyma adjacent to the airways owing to its characteristics of being real-time and minimally invasive. Although the incidence of lung cancer has been decreasing, it is and will be the leading cause of cancer-related mortality in the next few decades. When compared to other cancers, lung cancer kills more females than breast and colon cancers combined and more males than colon and prostate cancers combined. The type of lung cancer has changed in recent decades and adenocarcinoma has become the most frequent cell type. Prognosis of lung cancer depends upon the cell type and the staging at the time of diagnosis. The cell type and molecular characteristics of adenocarcinoma may allow individualized targeted treatment. Other malignant conditions in the mediastinum and lung (eg, metastatic lung cancers and lymphoma) can be biopsied using endobronchial ultrasound needles. Endobronchial ultrasound needle biopsies provides mostly cytology specimens due to its small sizes of needles (22 gauge or larger) which may not give enough tissue to make a definitive diagnosis in malignant (eg, lymphoma) or benign conditions (eg, sarcoidosis). EchoTip ProCore endobronchial needle released in early 2014 provides histologic biopsy material. Larger tissue biopsies may potentially provide a higher diagnostic yield and it eliminates mediastinoscopy or other surgical interventions. Here we aim to review bronchoscopic approach in the diagnosis of mediastinal lesions with emphasis of EchoTip ProCore needles. PMID:27099535

  11. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  12. Toward dynamic lumbar punctures guidance based on single element synthetic tracked aperture ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.

    2017-03-01

    Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.

  13. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    NASA Astrophysics Data System (ADS)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  14. Feasibility of Rotational Scan Ultrasound Imaging by an Angled High Frequency Transducer for the Posterior Segment of the Eye

    PubMed Central

    Paeng, Dong-Guk; Chang, Jin Ho; Chen, Ruimin; Humayun, Mark S.; Shung, K. Kirk

    2009-01-01

    High frequency ultrasound over 40 MHz has been used to image the anterior segment of the eye, but it is not suitable for the posterior segment due to the frequency-dependent attenuation of ultrasound and thus the limitation of penetration depth. This paper proposes a novel scan method to image the posterior segment of the eye with an angled high frequency (beyond 40 MHz) ultrasound needle transducer. In this method, the needle transducer is inserted into the eye through a small incision hole (∼1 mm in diameter) and rotated around the axial direction to form a cone-shaped imaging plane, allowing the spatial information of retinal vessels and diagnosis of their occlusion to be displayed. The feasibility of this novel technique was tested with images of a wire phantom, a polyimide tube, and an excised pig eye obtained by manually rotating a 40-MHz PMN-PT needle transducer with a beveled tip of 45°. From the results, we believe that rotational scan imaging will help expand the minimally invasive applications of high frequency ultrasound to other areas due to the capability of increased closeness of an angled needle transducer to structures of interest buried in other tissues. PMID:19411226

  15. Feasibility of rotational scan ultrasound imaging by an angled high frequency transducer for the posterior segment of the eye.

    PubMed

    Paeng, Dong-Guk; Chang, Jin Ho; Chen, Ruimin; Humayun, Mark S; Shung, K Kirk

    2009-03-01

    High frequency ultrasound over 40 MHz has been used to image the anterior segment of the eye, but it is not suitable for the posterior segment due to the frequency dependent attenuation of ultrasound and thus the limitation of penetration depth. This paper proposes a novel scan method to image the posterior segment of the eye with an angled high frequency (beyond 40 MHz) ultrasound needle transducer. In this method, the needle transducer is inserted into the eye through a small incision hole (approximately 1 mm in diameter) and rotated around the axial direction to form a cone-shaped imaging plane, allowing the spatial information of retinal vessels and diagnosis of their occlusion to be displayed. The feasibility of this novel technique was tested with images of a wire phantom, a polyimide tube, and an excised pig eye obtained by manually rotating a 40-MHz PMN-PT needle transducer with a beveled tip of 45 degrees . From the results, we believe that rotational scan imaging will help expand the minimally invasive applications of high frequency ultrasound to other areas due to the capability of increased closeness of an angled needle transducer to structures of interest buried in other tissues.

  16. Technical description of endoscopic ultrasonography with fine-needle aspiration for the staging of lung cancer.

    PubMed

    Kramer, Henk; van Putten, John W G; Douma, W Rob; Smidt, Alie A; van Dullemen, Hendrik M; Groen, Harry J M

    2005-02-01

    Endoscopic ultrasonography (EUS) is a novel method for staging of the mediastinum in lung cancer patients. The recent development of linear scanners enables safe and accurate fine-needle aspiration (FNA) of mediastinal and upper abdominal structures under real-time ultrasound guidance. However, various methods and equipment for mediastinal EUS-FNA are being used throughout the world, and a detailed description of the procedures is lacking. A thorough description of linear EUS-FNA is needed. A step-by-step description of the linear EUS-FNA procedure as performed in our hospital will be provided. Ultrasonographic landmarks will be shown on images. The procedure will be related to published literature, with a systematic literature search. EUS-FNA is an outpatient procedure under conscious sedation. The typical linear EUS-FNA procedure starts with examination of the retroperitoneal area. After this, systematic scanning of the mediastinum is performed at intervals of 1-2cm. Abnormalities are noted, and FNA of the abnormalities can be performed. Specimens are assessed for cellularity on-site. The entire procedure takes 45-60 min. EUS-FNA is minimally invasive, accurate, and fast. Anatomical areas can be reached that are inaccessible for cervical mediastinoscopy. EUS-FNA is useful for the staging of lung cancer or the assessment and diagnosis of abnormalities in the posterior mediastinum.

  17. Learning curve of thyroid fine-needle aspiration biopsy.

    PubMed

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Thyroid Swelling and Thyroiditis in the Setting of Recent hCG Injections and Fine Needle Aspiration

    PubMed Central

    Lamos, Elizabeth M.; Munir, Kashif M.

    2016-01-01

    A 60-year-old woman presented with a neck mass and underwent fine needle aspiration of a left thyroid nodule. During this time, she had been injected with hCG for weight loss. Soon after, she developed rapid diffuse thyroid growth with pain. She was ultimately diagnosed with thyrotoxicosis due to postaspiration subacute thyroiditis and subsequently became hypothyroid. This condition is rare in the nonpregnant state in noncystic nodules with a smaller needle gauge approach. The incidence of thyroid nodule discovery and evaluation is increasing. As more procedures are undertaken, understanding of potential complications is important. This case highlights potential complications of thyroid fine needle aspiration including diffuse thyroid swelling and thyroiditis. The role of hCG injections is speculated to have potentially stimulated thyroid follicular epithelium via cross-reactivity with the TSH receptor and contributed to the acute inflammatory response after fine needle aspiration. PMID:26942022

  19. Needle placement for piriformis injection using 3-D imaging.

    PubMed

    Clendenen, Steven R; Candler, Shawn A; Osborne, Michael D; Palmer, Scott C; Duench, Stephanie; Glynn, Laura; Ghazi, Salim M

    2013-01-01

    Piriformis syndrome is a pain syndrome originating in the buttock and is attributed to 6% - 8% of patients referred for the treatment of back and leg pain. The treatment for piriformis syndrome using fluoroscopy, computed tomography (CT), electromyography (EMG), and ultrasound (US) has become standard practice. The treatment of Piriformis Syndrome has evolved to include fluoroscopy and EMG with CT guidance. We present a case study of 5 successful piriformis injections using 3-D computer-assisted electromagnet needle tracking coupled with ultrasound. A 6-degree of freedom electromagnetic position tracker was attached to the ultrasound probe that allowed the system to detect the position and orientation of the probe in the magnetic field. The tracked ultrasound probe was used to find the posterior superior iliac spine. Subsequently, 3 points were captured to register the ultrasound image with the CT or magnetic resonance image scan. Moreover, after the registration was obtained, the navigation system visualized the tracked needle relative to the CT scan in real-time using 2 orthogonal multi-planar reconstructions centered at the tracked needle tip. Conversely, a recent study revealed that fluoroscopically guided injections had 30% accuracy compared to ultrasound guided injections, which tripled the accuracy percentage. This novel technique exhibited an accurate needle guidance injection precision of 98% while advancing to the piriformis muscle and avoiding the sciatic nerve. The mean (± SD) procedure time was 19.08 (± 4.9) minutes. This technique allows for electromagnetic instrument tip tracking with real-time 3-D guidance to the selected target. As with any new technique, a learning curve is expected; however, this technique could offer an alternative, minimizing radiation exposure.

  20. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    PubMed

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  1. Ultrasound-guided thermocouple placement for cryosurgery.

    PubMed

    Abramovits, W; Pruiksma, R; Bose, S

    1996-09-01

    Although cryosurgical methods have high cure rates, imprecise estimates of both skin lesion depth and destructive temperature front location result in subjective technique in skin malignancy treatments. We evaluated the possibility of newer ultrasound equipment to assist in the precise placement of thermocouples in human skin. DermaScan C ver. 3 ultrasonographic equipment fitted with a sharp focus probe with a frequency of 20 MHz and a scan length of 12.1 mm was used to locate thermocouples with 27- and 30-gauge needles. We successfully and reproducibly located thermocouples and thin needles, and accurately measured their distance from the skin surface. Ultrasound is a useful method for the accurate placement of thermocouples, and needles as thin as 30 gauge for monitoring in cryosurgery.

  2. Novel Magnetic Resonance Detection and Profiling of Ovarian Cancer Across Specimens

    DTIC Science & Technology

    2012-10-01

    Cancer Cells in Fine - Needle Aspirates. Proc. Natl. Acad. Sci. U.S.A. 2009, 106, 12459–12464. 25. Han,H. S.; Devaraj,N. K.; Lee, J.; Hilderbrand, S.A... fine needle aspirates, biopsies, ascites, blood, sputum), which are inherently complex in composition, as well as heterogeneous and variable in cell...in ascitic fluid, we anticipate that this method could similarly be applied to fine needle aspirates, blood, biopsy spec- imens, sputum, and other

  3. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  4. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    PubMed

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p < 0.001 and p = 0.009, respectively) and MRI (p = 0.045 and p = 0.036, respectively). The percentage diameter decrease, size of tumour deposit in LN, progesterone receptor, HER2 and histological grade were significantly associated with the diagnostic performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with diagnostic performance of ultrasound and PET/CT. This study is about the diagnostic performance of ultrasound, MRI, PET/CT and combination of each imaging modality for the evaluation of metastatic ALN after NAC. Of many histopathological factors, only the size of tumour deposit within ALN was an independent factor associated with the diagnostic performance of ultrasound and PET/CT.

  5. Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces

    PubMed Central

    Abayazid, Momen; Moreira, Pedro; Shahriari, Navid; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    In this paper, we present a system capable of automatically steering a bevel-tipped flexible needle under ultrasound guidance toward a physical target while avoiding a physical obstacle embedded in gelatin phantoms and biological tissue with curved surfaces. An ultrasound pre-operative scan is performed for three-dimensional (3D) target localization and shape reconstruction. A controller based on implicit force control is developed to align the transducer with curved surfaces to assure the maximum contact area, and thus obtain an image of sufficient quality. We experimentally investigate the effect of needle insertion system parameters such as insertion speed, needle diameter and bevel angle on target motion to adjust the parameters that minimize the target motion during insertion. A fast sampling-based path planner is used to compute and periodically update a feasible path to the target that avoids obstacles. We present experimental results for target reconstruction and needle insertion procedures in gelatin-based phantoms and biological tissue. Mean targeting errors of 1.46 ± 0.37 mm, 1.29 ± 0.29 mm and 1.82 ± 0.58 mm are obtained for phantoms with inclined, curved and combined (inclined and curved) surfaces, respectively, for insertion distance of 86–103 mm. The achieved targeting errors suggest that our approach is sufficient for targeting lesions of 3 mm radius that can be detected using clinical ultrasound imaging systems. PMID:25455165

  6. Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students

    ERIC Educational Resources Information Center

    de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina

    2018-01-01

    The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…

  7. Deep Needle Procedures: Improving Safety With Ultrasound Visualization

    PubMed Central

    Peabody, Christopher R.; Mandavia, Diku

    2017-01-01

    Abstract Promoting patient safety and increasing health care quality have dominated the health care landscape during the last 15 years. Health care regulators and payers are now tying patient safety outcomes and best practices to hospital reimbursement. Many health care leaders are searching for new technologies that not only make health care for patients safer but also reduce overall health care costs. New advances in ultrasonography have made this technology available to health care providers at the patient’s bedside. Point-of-care ultrasound assistance now aids providers with real-time diagnosis and with visualization for procedural guidance. This is especially true for common deep needle procedures such as central venous catheter insertion, thoracentesis, and paracentesis. There is now mounting evidence that clinician-performed point-of-care ultrasound improves patient safety, enhances health care quality, and reduces health care cost for deep needle procedures. Furthermore, the miniaturization, ease of use, and the evolving affordability of ultrasound have now made this technology widely available. The adoption of point-of-care ultrasonography has reached a tipping point and should be seriously considered the safety standard for all hospital-based deep needle procedures. PMID:24786918

  8. [Lactational breast abscesses: Do we still need surgery?].

    PubMed

    Debord, M-P; Poirier, E; Delgado, H; Charlot, M; Colin, C; Raudrant, D; Golfier, F; Dupuis, O

    2016-03-01

    To show the effectiveness of ultrasound-guided puncture in the treatment of lactational breast abscess and identify its risk factors. Retrospective descriptive study at the CHU of Lyon-Sud from December 2007 to December 2013, including patients with lactational breast abscess confirmed on ultrasound and treated with antibiotics and analgesics. Realisation of ultrasound-guided needle under local anesthesia by the radiologist and washing the cavity with physiological serum. Forty patients had lactational abscesses at an average of 10 weeks post-partum. Thirty-four patients were treated by needle aspiration, of which 2 had first surgical drainage. The average size of the abscess was 41.2mm. The success rate of needle aspiration was 91.2%. No cases of recurrence were observed, however, there were 5 fistulisations. In all, 91.2% were treated on an outpatient basis. In 87.8% of cases, breastfeeding was continued on the healthy side and in 48.5% of cases on the affected side. The major risk factor for abscess was mastitis in 91.1% of cases. Ultrasound guidance of needle aspiration should be gold standard for the treatment of lactational breast abscesses to continue breastfeeding including the affected side. Copyright © 2015. Published by Elsevier Masson SAS.

  9. Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study

    PubMed Central

    DeWitt, John; Cho, Chang-Min; Lin, Jingmei; Al-Haddad, Mohammad; Canto, Marcia Irene; Salamone, Ashley; Hruban, Ralph H.; Messallam, Ahmed A.; Khashab, Mouen A.

    2015-01-01

    Background and study aims: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United States) to a conventional 19-gauge Tru-Cut biopsy (EUS-TCB) needle (19G, Quick-Core, Cook Medical Inc.). Patients and methods: Patients referred for EUS who require possible histologic biopsy were prospectively randomized to EUS-FNB or EUS-TCB. With the initial needle, ≤ 3 biopsies were obtained until either technical failure or an adequate core was obtained. Patients with suspected inadequate biopsies were crossed over to the other needle and similarly ≤ 3 passes were obtained until adequate cores or technical failure occurred. Technical success, diagnostic histology, accuracy and complication rates were evaluated. Results: Eighty-five patients (mean 58 years; 43 male) were randomized to FNB (n = 44) and TCB (n = 41) with seven patients excluded. Procedure indication, biopsy site, mass size, number of passes, puncture site, overall technical success and adverse events were similar between the two groups. FNB specimens had a higher prevalence of diagnostic histology (85 % vs. 57 %; P = 0.006), accuracy (88 % vs. 62 %; P = 0.02), mean total length (19.4 vs. 4.3 mm; P = 0.001), mean complete portal triads from liver biopsies (10.4 vs. 1.3; P = 0.0004) and required fewer crossover biopsies compared to those of TCB (2 % vs. 65 %; P = 0.0001). Overall technical success and complication rates were comparable. Conclusion: EUS-FNB using a 19-gauge FNB needle is superior to 19-gauge EUS-TCB needle. PMID:26528504

  10. Clinico-pathological Correlation of Thyroid Nodule Ultrasound and Cytology Using the TIRADS and Bethesda Classifications.

    PubMed

    Singaporewalla, R M; Hwee, J; Lang, T U; Desai, V

    2017-07-01

    Clinico-pathological correlation of thyroid nodules is not routinely performed as until recently there was no objective classification system for reporting thyroid nodules on ultrasound. We compared the Thyroid Imaging Reporting and Data System (TIRADS) of classifying thyroid nodules on ultrasound with the findings on fine-needle aspiration cytology (FNAC) reported using the Bethesda System. A retrospective analysis of 100 consecutive cases over 1 year (Jan-Dec 2015) was performed comparing single-surgeon-performed bedside thyroid nodule ultrasound findings based on the TIRADS classification to the FNAC report based on the Bethesda Classification. TIRADS 1 (normal thyroid gland) and biopsy-proven malignancy referred by other clinicians were excluded. Benign-appearing nodules were reported as TIRADS 2 and 3. Indeterminate or suspected follicular lesions were reported as TIRADS 4, and malignant-appearing nodules were classified as TIRADS 5 during surgeon-performed bedside ultrasound. All the nodules were subjected to ultrasound-guided FNAC, and TIRADS findings were compared to Bethesda FNAC Classification. Of the 100 cases, 74 were considered benign or probably benign, 20 were suspicious for malignancy, and 6 were indeterminate on ultrasound. Overall concordance rate with FNAC was 83% with sensitivity and specificity of 70.6 and 90.4%, respectively. The negative predictive value was 93.8%. It is essential for clinicians performing bedside ultrasound thyroid and guided FNAC to document their sonographic impression of the nodule in an objective fashion using the TIRADS classification and correlate with the gold standard cytology to improve their learning curve and audit their results.

  11. Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.

    PubMed

    Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A

    2010-02-01

    Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.

  12. Sci-Thur AM: YIS – 03: Combining sagittally-reconstructed 3D and live-2D ultrasound for high-dose-rate prostate brachytherapy needle segmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hrinivich, Thomas; Hoover, Douglas; Surry, Kathlee

    Ultrasound-guided high-dose-rate prostate brachytherapy (HDR-BT) needle segmentation is performed clinically using live-2D sagittal images. Organ segmentation is then performed using axial images, introducing a source of geometric uncertainty. Sagittally-reconstructed 3D (SR3D) ultrasound enables both needle and organ segmentation, but suffers from shadow artifacts. We present a needle segmentation technique augmenting SR3D with live-2D sagittal images using mechanical probe tracking to mitigate image artifacts and compare it to the clinical standard. Seven prostate cancer patients underwent TRUS-guided HDR-BT during which the clinical and proposed segmentation techniques were completed in parallel using dual ultrasound video outputs. Calibrated needle end-length measurements were usedmore » to calculate insertion depth errors (IDEs), and the dosimetric impact of IDEs was evaluated by perturbing clinical treatment plan source positions. The proposed technique provided smaller IDEs than the clinical approach, with mean±SD of −0.3±2.2 mm and −0.5±3.7mm respectively. The proposed and clinical techniques resulted in 84% and 43% of needles with IDEs within ±3mm, and IDE ranges across all needles of [−7.7mm, 5.9mm] and [−9.3mm, 7.7mm] respectively. The proposed and clinical IDEs lead to mean±SD changes in the volume of the prostate receiving the prescription dose of −0.6±0.9% and −2.0±5.3% respectively. The proposed technique provides improved HDR-BT needle segmentation accuracy over the clinical technique leading to decreased dosimetric uncertainty by eliminating the axial-to-sagittal registration, and mitigates the effect of shadow artifacts by incorporating mechanically registered live-2D sagittal images.« less

  13. An ultrasound needle insertion guide in a porcine phantom model.

    PubMed

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  14. Analysis of "dry" mesothelioma with ultrasound guided biopsies.

    PubMed

    Stigt, Jos A; Boers, James E; Groen, Harry J M

    2012-12-01

    Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with a low rate of failure and a low rate of complications. Our clinical experience suggests that a randomized trial is warranted to compare the SonixGPS with a standard block technique.

  16. [Role of cytology in hematopathological diagnostics].

    PubMed

    Bode, B; Tinguely, M

    2012-07-01

    The role of cytology has so far been underrecognized in the diagnostic process of hematopathological questions. This article presents an algorithm which allows a stepwise work-up of cytology specimens obtained by minimally invasive ultrasound-guided fine needle aspiration in patients with unexplained lymph node swelling. Moreover, it is shown how the selective separation of cytology specimens allows the application of immunophenotypic analysis including flow cytometry and immunohistochemistry as well as molecular analyses, such as fluorescence in situ hybridization (FISH) and polymerase chain reaction (PCR) strategies. With the integrative procedure presented, cytology offers an excellent cost-effective tool for the diagnostic approach of patients with suspected hematopathological malignancies allowing a high diagnostic accuracy, ideal for initial diagnosis or follow-up.

  17. Utilization of Ancillary Studies in the Cytologic Diagnosis of Respiratory Lesions

    PubMed Central

    Layfield, Lester J.; Roy-Chowdhuri, Sinchita; Baloch, Zubair; Ehya, Hormoz; Geisinger, Kim; Hsiao, Susan J.; Lin, Oscar; Lindeman, Neal I.; Roh, Michael; Schmitt, Fernando; Sidiropoulos, Nikoletta; VanderLaan, Paul A.

    2017-01-01

    The Papanicolaou Society of Cytopathology has developed a set of guidelines for respiratory cytology including indications for sputum examination, bronchial washings and brushings, CT-guided FNA and endobronchial ultrasound guided fine needle aspiration (EBUS-FNA), as well as recommendations for classification and criteria, ancillary testing and post-cytologic diagnosis management and follow-up. All recommendation documents are based on the expertise of committee members, an extensive literature review, and feedback from presentations at national and international conferences. The guideline documents selectively present the results of these discussions. The present document summarizes recommendations for ancillary testing of cytologic samples. Ancillary testing including microbiologic, immunocytochemical, flow cytometric, and molecular testing, including next-generation sequencing are discussed. PMID:27561242

  18. Transrectal EUS-guided FNA biopsy of a presacral chordoma-report of a case and review of the literature

    PubMed Central

    Gottlieb, Klaus; Lin, Paul H; Liu, David M; Anders, Karl

    2008-01-01

    Chordomas are rare tumors which originate from the remnants of the notochord. These tumors are locally aggressive and have a predilection for the ends of the axial skeleton. An important prerequisite for optimal management of these tumors is a correct preoperative diagnosis. The present case is the first report of the use of endoscopic ultrasound to obtain transrectal fine needle aspiration biopsy of a presacral chordoma. A review of the prior computer tomography (CT) scans allowed us to calculate the tumor volume doubling time (18.3 mo). Transrectal biopsy of chordomas is controversial, however we believe that such concerns are not justified. PMID:18442211

  19. Promise and pitfalls of molecular markers of thyroid nodules

    PubMed Central

    Jadhav, S.; Lila, Anurag; Bandgar, Tushar; Shah, Nalini

    2012-01-01

    Thyroid nodules are common in the general population with a prevalence of 5-7% The initial evaluation of thyroid nodules commonly involves thyroid function tests, an ultrasound (USG) and fine needle aspiration biopsy (FNAB). The optimal management of patients with thyroid nodules with indeterminate cytology is plagued by the lack of highly sensitive and specific diagnostic modalities In this article we attempt to review the available literature on the molecular markers which are increasingly being studied for their diagnostic utility in assessing thyroid nodules. The various molecular markers consist of gene mutations, gene re arrangements, RNA based assays and immunohistochemical markers. The molecular markers definitely would help to optimise the management of such patients. PMID:23565369

  20. Bilateral adrenal histoplasmosis: endoscopic ultrasound-guided fine needle aspiration as a method of diagnosis and assessment.

    PubMed

    Azhar, J Khairul; Jacqueline, H S G; Tony, L K H; Tan, B H; Steven, J M

    2011-12-01

    We report a case of a healthy 78-year-old indonesian man who presented with chronic weight loss, poor appetite and lethargy. CT abdomen showed bilateral adrenal masses. EUS-guided FNA was performed on the left adrenal gland. Histopathology report was Histoplasma Capsulatum. He recovered well with antifungal treatment without any complication. In this case, we found that the role of EUS -guided FNA was not only limited to diagnosis but also helped in the prognosis of the disease since the method was able to assess the general anatomy of the adrenal gland better than other imaging modalities due to its close proximity and direct visualization.

  1. [Lymphadenopathy caused by Toxoplasma in an intramammary lymph node: role of molecular biology in the diagnosis].

    PubMed

    Voglino, G; Arisio, R; Novero, D; Marchi, C; Fessia, L

    1997-08-01

    We describe a case of Toxoplasma gondii lymphoadenopathy in an intramammary lymph node in a 22 year old woman. Clinical evidence and ultrasound were suggestive for fibroadenoma, while cytology on fine needle aspiration suspected a lymphomatous lesion. The pathological examination demonstrated a lymph node with granulomatous foci with epithelioid histiocytes, consistent with Toxoplasma gondii lymphadenopathy. The pathological finding was confirmed by serological tests and by PCR (Polymerase Chain Reaction) using specific primers designed on ribosomal 18s DNA sequence of Toxoplasma gondii. The aim of this work is to emphasize the role of molecular biology techniques as an aid to pathological diagnosis in parasite diseases.

  2. 3D-ultrasound in imaging, diagnosis and follow-up of an atypical hydatid cyst.

    PubMed

    Ockenga, J; Gebel, M; Caselitz, M; Topalidis, T; Boozari, B; Bleck, J; Manns, M P

    1998-07-01

    Abdominal ultrasonography is the procedure of choice to diagnose hydatid cysts caused by Echinococcus granulosus. Recently three-dimensional ultrasonography has become available for clinical application. We report a case of an atypical seronegative hydatid disease, in which the additional use of 3D-sonography improved the sonographic diagnosis, which was confirmed by a fine needle biopsie complicated by an anaphylactic reaction. In addition the potential advantage of 3D-ultrasonography in diagnosis and follow-up hydatid disease will be discussed, especially in the context of new alternative therapeutic options like chemotherapy with benzimidazoles or the percutaneous drainage by the PAIR procedure (puncture-aspiration-injection-re-aspiration).

  3. SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kapoor, P; Kapoor, R; Curran, B

    Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work,more » two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.« less

  4. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  5. The role of endobronchial ultrasound versus mediastinoscopy for non-small cell lung cancer.

    PubMed

    Czarnecka-Kujawa, Katarzyna; Yasufuku, Kazuhiro

    2017-03-01

    This review provides an update on the current role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and mediastinoscopy (Med) in assessment of patients with non-small cell lung cancer (NSCLC). Invasive mediastinal lymph node (LN) staging is the major application for both of these techniques. Up until recently, Med was the gold standard for invasive mediastinal LN staging in NSCLC. However, EBUS-TBNA has shown to be equivalent, and in some studies better than Med for invasive staging of lung cancer. EBUS-TBNA offers access to N1 LNs and development of the thin convex probe EBUS (TCP-EBUS) will expand EBUS-TBNA access from the paratracheal region and central airways to more distal parabronchial regions allowing for more extensive N1 LN assessment and sampling more distal lung tumors. EBUS-TBNA is more cost-effective than Med and it is currently recommended as the test of first choice for invasive mediastinal LN staging in lung cancer. Confirmatory Med should be performed selectively in patients with high pretest probability of metastatic disease. Addition of esophageal ultrasound fine needle aspiration (EUS-FNA) may increase diagnostic yield of EBUS-TBNA mediastinal staging. Both Med and EBUS-TBNA can be used in primary lung cancer diagnosis, restaging of the mediastinum following neoadjuvant therapy and in diagnosis of lung cancer recurrence. In the future, a combination of EBUS-TBNA with or without EUS-FNA and Med is most likely going to provide the most optimal invasive assessment of the mediastinum in patients with lung cancer. The decision on test choice and sequence should be made on a case-by-case basis and factoring in local resources and expertise.

  6. [Values and limits in fine needle aspiration in the diagnosis of Warthin tumour of the parotid gland].

    PubMed

    Righi, A; Foschini, M P

    2006-12-01

    Recent paper state that cytological diagnosis of Warthin Tumour of the parotid gland is poorly reproducible and that aspiration procedures damage the tumoral tissue as to make difficult the histological diagnosis. Aim of the present study is to review cytological sampling performed with fine needle sampling without aspiration and to compare them with the relative surgical specimens in order to determine the value of fine needle aspiration in the diagnosis of Warthin Tumour and to quantify' the damage in histological tissue. All cases with cytological and/or histological diagnosis of Warthin Tumour during the period 1/1/98 to 30/6/04 were retrieved. In all cases both cytological and histological slides were reviewed and compared. In all cases fine needle aspiration (FNA) was performed according to the technique described by Zajdela et al. in 1987. A cytologic sample was considered diagnostic when there were in the same sample mucoid substance, lymphocytes scattered with a range of maturation and oncocytes organized in flat sheets of cells. 38 cases were selected corresponding to 37 patients (1 case of Warthin Tumour bilateral): all tumors were localized in the parotid gland. Fine needle sampling were 43. Nine cytological sample (20.9%) were inadequate. Sensitivity and specificity, in the preent series, had the same value, being 97.1%. A spectrum of histologic alterations were observed in 30/38 cases (79%). These alterations were squamous metaplasia (7 cases), acute and chronic hemorrhage and inflammation with multinucleated giant cells (26 cases) and granulation tissue with subsequent fibrosis (24 cases). In all cases the histologic alterations from fine needle were focal, limited to less than 20% of the tumoral area (first category of Batsakis 'classification), and did not prevent the histologic diagnosis of Warthin Tumour. These data suggest that fine needle aspiration without aspiration is a valuable tool for the per-operative diagnosis of Warthin Tumour. In addition it creates only minor histological changes, that always allow the histological diagnosis.

  7. Diagnosis and successful treatment of a lung abscess associated with Brucella species infection in a bottlenose dolphin (Tursiops truncatus).

    PubMed

    Cassle, Stephen E; Jensen, Eric D; Smith, Cynthia R; Meegan, Jennifer M; Johnson, Shawn P; Lutmerding, Betsy; Ridgway, Sam H; Francis-Floyd, Ruth

    2013-06-01

    This brief communication describes the clinical presentation, antemortem diagnosis, and successful treatment of a pulmonary abscess associated with a Brucella sp. in a 27-yr-old female bottlenose dolphin (Tursiops truncatus). Ultrasound revealed a 3-cm diameter hypoechoic mass deep to the pleural lining in the left lung field. Multiple ultrasound-guided fine-needle aspirates were performed and tested for bacterial and fungal etiology. All cultures were negative, but the infectious agent was identified by MicroSEQ analysis in two samples and confirmed with real-time polymerase chain reaction (PCR) amplification using known Brucella sp. primers. Amikacin was infused into the abscess and was followed by an oral doxycycline and rifampin protocol. Follow-up diagnostic imaging, including radiographs and computed tomography, revealed a resolved lesion with minimal mineralization within the affected lung fields. Brucellosis should be considered for pulmonary disease in dolphins, and personnel who interact with marine animals should use caution to prevent zoonotic brucellosis.

  8. Leiomyosarcoma of the stomach treated by endoscopic submucosal dissection.

    PubMed

    Sato, Takao; Akahoshi, Kazuya; Tomoeda, Naru; Kinoshita, Norikatsu; Kubokawa, Masaru; Yodoe, Kentaro; Hiraki, Yuka; Oya, Masafumi; Yamamoto, Hidetaka; Ihara, Eikichi

    2018-03-02

    There have been no reports of primary leiomyosarcoma of the stomach treated by endoscopic submucosal dissection (ESD). We report an extremely rare case of gastric leiomyosarcoma that was successfully treated by ESD. An asymptomatic 74-year-old female underwent esophagogastroduodenoscopy for screening in December 2013. A centrally depressed submucosal tumor 10 mm in diameter was detected at the posterior wall of the upper gastric body. Follow-up esophagogastroduodenoscopy conducted 5 months later showed that the tumor diameter had increased to 15 mm. Endoscopic ultrasound revealed a hypoechoic mass located in the second to the middle of the third layer. Endoscopic ultrasound-guided fine-needle aspiration demonstrated a myogenic tumor. The tumor was completely resected by ESD without complications. Immunohistopathological diagnosis of the resected specimen was gastric leiomyosarcoma derived from the muscularis mucosae, with negative lateral and vertical margins. No local recurrence or metastasis has been detected at 36 months after ESD. This is the first report of gastric leiomyosarcoma treated by ESD in the English language literature.

  9. Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis

    DTIC Science & Technology

    2011-06-01

    integrated needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for... needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study...tissue, into a transrectal- ultrasound , needle - biopsy probe. In the development phase, documentation to obtain IRB approval for ex vivo human prostate

  10. Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.

    PubMed

    Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K

    2015-02-01

    We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.

  11. Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography

    PubMed Central

    Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.

    2014-01-01

    Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257

  12. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  13. Stereotaxic fine-needle aspiration of low-suspicion, nonpalpable breast nodules: valid alternative to follow-up mammography.

    PubMed

    Franquet, T; Cozcolluela, R; De Miguel, C

    1992-06-01

    Seventy "low-suspicion," nonpalpable solid breast nodules were evaluated with stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography. Sonography was performed in all cases to determine the solid nature of the nodules. Eight cysts were incorrectly classified with sonography, corresponding to atypical cysts; in such cases, however, stereotaxic fine-needle aspiration not only enabled the diagnosis, but was therapeutic as well. Fifty-eight of 70 breast aspirates (83%) yielded adequate cellular material for cytologic interpretation. A specific cytologic diagnosis was made in 52 cases (51 benign, one malignant). Insufficient cytologic material was obtained in 12 cases (17%). These results should help establish the validity of stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography in patients with low-suspicion, solid breast nodules, reducing radiation exposure, patient anxiety, unnecessary biopsies, and costs.

  14. Feasibility of Prostate Cancer Diagnosis by Transrectal Photoacoustic Imaging

    DTIC Science & Technology

    2012-03-01

    cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the prostate. Transrectal ultrasound has...been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for detecting prostate cancer due to...Research Systems, CA) and used as a reference signal. The sample and the ultrasound transducer (UST, Olympus NDT, one inch in focal length) are

  15. Guided percutaneous fine-needle aspiration biopsy of the liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, C.S.; McLoughlin, M.J.; Tao, L.C.

    1981-04-01

    Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less

  16. Fine needle aspiration cytology in lymphadenopathy of HIV-positive cases.

    PubMed

    Saikia, U N; Dey, P; Jindal, B; Saikia, B

    2001-01-01

    To evaluate the role of fine needle aspiration biopsy (FNAB) material in 25 HIV-positive cases with lymphadenopathy. We selected 25 cases for the present study who were enzyme-linked immunosorbent assay positive for HIV (HIV-1). FNAB was performed as a routine, outdoor procedure with informed consent of the patient. For each case, along with routine May-Grünwald-Giemsa and hematoxylin and eosin staining, Ziehl-Neelsen staining for acid-fast bacilli and periodic acid-Schiff staining for fungi were performed wherever necessary. A total of 28 sites were aspirated from 25 HIV patients. All these patients were heterosexual, and none had a history of drug abuse. FNAB was performed under ultrasound guidance in all four cases of a retroperitoneal group of lymph nodes. The most common FNAB diagnosis was reactive lymphoid hyperplasia (10), followed by tuberculosis (8). There were three cases diagnosed as fungal infection (two, Cryptococcus; one, histoplasmosis). FNAB of a case of lymph node was suggestive of tuberculosis. There was one case each diagnosed as non-Hodgkin's lymphoma and squamous cell carcinoma (metastatic). One case of a small axillary lymph node did not yield representative material. FNAB is a relatively inexpensive initial investigative technique in the diagnosis and management of HIV-positive patients. It can obviate the need for surgical excision and enable immediate treatment of specific infections.

  17. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    PubMed

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  18. A Novel Technology for Localization of Parathyroid Adenoma: Ultrasound-Guided Fine Needle Aspiration Combined With Rapid Parathyroid Hormone Detection and Nano-Carbon Technology.

    PubMed

    Yan, Shouyi; Zhao, Wenxin; Wang, Bo; Zhang, Liyong

    2018-06-01

    The study aims to evaluate the clinic feasibility of rapid parathyroid hormone (PTH) detection and nano-carbon technology in preoperative diagnosis and localization of parathyroid adenoma. With the guidance of ultrasound, the operator performed the parathyroid puncture and tested the PTH value by using a PTH test kit, and then injected nano-carbon into parathyroid adenoma as a marker to observe whether the parathyroid adenoma was stained black during the final operation. Meanwhile, a part of excised specimen was made into homogenate and detected rapidly again by using the PTH test kit. The remaining was confirmed by intraoperative frozen pathological examination. The sensitivity (12/12) of preoperative diagnosis was significantly higher than that of ultrasound (6/12), magnetic resonance imaging (7/12), and MIBI (9/12). During the operation, we found that the inner part of the parathyroid adenoma was stained black, and the PTH value of the specimen homogenate confirmed as parathyroid adenoma was more than 3000 pg/mL. This novel technology, as a very positive method for localization of parathyroid adenoma, plays an important role in guaranteeing the surgical reliability of parathyroid adenoma with help of nano-carbon technology.

  19. Real-time 3D ultrasound guidance of autonomous surgical robot for shrapnel detection and breast biopsy

    NASA Astrophysics Data System (ADS)

    Rogers, Albert J.; Light, Edward D.; von Allmen, Daniel; Smith, Stephen W.

    2009-02-01

    Two studies have been conducted using real time 3D ultrasound and an automated robot system for carrying out surgical tasks. The first task is to perform a breast lesion biopsy automatically after detection by ultrasound. Combining 3D ultrasound with traditional mammography allows real time guidance of the biopsy needle. Image processing techniques analyze volumes to calculate the location of a target lesion. This position was converted into the coordinate system of a three axis robot which moved a needle probe to touch the lesion. The second task is to remove shrapnel from a tissue phantom autonomously. In some emergency situations, shrapnel detection in the body is necessary for quick treatment. Furthermore, small or uneven shrapnel geometry may hinder location by typical ultrasound imaging methods. Vibrations and small displacements can be induced in ferromagnetic shrapnel by a variable electromagnet. We used real time 3D color Doppler to locate this motion for 2 mm long needle fragments and determined the 3D position of the fragment in the scanner coordinates. The rms error of the image guided robot for 5 trials was 1.06 mm for this task which was accomplished in 76 seconds.

  20. Ultrasound-guided evaluation of the lumbar subarachnoid space in lateral and sitting positions in pregnant patients to receive elective cesarean operation.

    PubMed

    Gulay, Ucarli; Meltem, Turkay; Nadir, Sinikoglu Sitki; Aysin, Alagol

    2015-01-01

    The aim was to compare visibility of the spinal space in sitting and lateral positions, number of attempts, spinal needle depth, skin-dura mater distance and the possible complications; in application of spinal anesthesia, using ultrasound in pregnant patients scheduled to receive elective cesarean operations. The study was conducted prospective-randomly after receiving approval from the ethics committee and the patients' permission. ASA I-II 50 pregnant patients were divided into two groups. The patients in Group SP were those placed in a sitting position and the patients in Group LP were those placed in a lateral position. In both groups, the skin-dura mater distance was recorded through an out-of plane technique accompanied by ultrasound. The depth of the spinal needle was measured. The number of attempts, the level of attempts recorded. The degree of visibility of the vertebral space was observed through ultrasound and was numerically scored. Intraoperative and postoperative complications were recorded. There was no difference between the number of attempts, Modified Bromage Scale and mean measurements of skin-dura mater distance observed through ultrasound. The mean needle depths of Group LP were statistically found significantly higher than Group SP (p=0.002). Our study supports the notion that access to the skin-dura mater distance is longer in the lateral decubitus position when skin-dura mater distance is evaluated by measuring needle depth.

  1. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  2. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  3. Examples of Radiation-Emitting Products

    MedlinePlus

    ... Ultrasonography • Doppler ultrasound • Color doppler ultrasound • Hyperthermia • Diathermy/physical therapy • Bone healing • Lithotripsy • Phacoemulsifier • Needle guide • Bone density measuring • Geriatric bath (ultrasound) • Hearing aid • Many scientific uses • Nondestructive ...

  4. Comparison of the coracoid and retroclavicular approaches for ultrasound-guided infraclavicular brachial plexus block.

    PubMed

    Kavrut Ozturk, Nilgun; Kavakli, Ali Sait

    2017-08-01

    This prospective randomized study compared the coracoid and retroclavicular approaches to ultrasound-guided infraclavicular brachial plexus block (IBPB) in terms of needle tip and shaft visibility and quality of block. We hypothesized that the retroclavicular approach would increase needle tip and shaft visibility and decrease the number of needle passes compared to the coracoid approach. A total of 100 adult patients who received IBPB block for upper limb surgery were randomized into two groups: a coracoid approach group (group C) and a retroclavicular approach group (group R). In group C, the needle was inserted 2 cm medial and 2 cm inferior to the coracoid process and directed from ventral to dorsal. In group R, the needle insertion point was posterior to the clavicle and the needle was advanced from cephalad to caudal. All ultrasound images were digitally stored for analysis. The primary aim of the present study was to compare needle tip and shaft visibility between the coracoid approach and retroclavicular approach in patients undergoing upper limb surgery. The secondary aim was to investigate differences between the two groups in the number of needle passes, sensory and motor block success rates, surgical success rate, block performance time, block performance-related pain, patient satisfaction, use of supplemental local anesthetic and analgesic, and complications. Needle tip visibility and needle shaft visibility were significantly better in group R (p = 0.040, p = 0.032, respectively). Block performance time and anesthesia-related time were significantly shorter in group R (p = 0.022, p = 0.038, respectively). Number of needle passes was significantly lower in group R (p = 0.044). Paresthesia during block performance was significantly higher in group C (p = 0.045). There were no statistically significant differences between the two groups in terms of sensory or motor block success, surgical success, block-related pain, and patient satisfaction. The retroclavicular approach is associated with better needle tip and shaft visibility, reduced performance time and anesthesia-related time, less paresthesia during block performance, and fewer needle passes than the coracoid approach. TRıAL REGISTRY NUMBER: Clinicaltrials.gov (no. NCT02673086).

  5. Cadaveric and Ultrasonographic Validation of Needling Placement in the Cervical Multifidus Muscle.

    PubMed

    Fernández-de-Las-Peñas, César; Mesa-Jiménez, Juan A; Paredes-Mancilla, Jose A; Koppenhaver, Shane L; Fernández-Carnero, Samuel

    2017-06-01

    The aim of this study was to determine if a needle is able to reach the cervical multifidus during the application of dry needling or acupuncture. Dry needling and ultrasound imaging of cervical multifidi was conducted on 5 patients (age: 32 ± 5 years) with mechanical neck pain and on 2 fresh cadavers (age: 64 ± 1 years). Dry needling was done using a needle of 40 mm in length inserted perpendicular to the skin about 1 cm lateral to the spinous process at C3-C4. The needle was advanced from a posterior to anterior direction into the cervical multifidus with a slight inferior-medial angle (approximately 10°) to reach the vertebra lamina. For the cadaveric study, the multifidus was isolated by carefully resecting the superficial posterior cervical muscles: trapezius, splenius, and semispinalis. For the ultrasonographic study, a convex transducer was placed transversely over C3-C4 after the insertion of the needle into the muscle. The results of both the cadaveric and ultrasonic studies found that the needle does pierce the cervical multifidus muscle during insertion and that the tip of the needle rests properly against the vertebral laminae, thereby guarding the sensitive underlying spinal structures from damage. This anatomical and ultrasound imaging study supports that dry needling of the cervical multifidus could be conducted clinically. Copyright © 2017. Published by Elsevier Inc.

  6. Ultrasound-Guided Percutaneous Thyroid Nodule Core Biopsy: Clinical Utility in Patients with Prior Nondiagnostic Fine-Needle Aspirate

    PubMed Central

    Vij, Abhinav; Seale, Melanie K.; Desai, Gaurav; Halpern, Elkan; Faquin, William C.; Parangi, Sareh; Hahn, Peter F.; Daniels, Gilbert H.

    2012-01-01

    Background Five percent to 20% of thyroid nodule fine-needle aspiration (FNA) samples are nondiagnostic. The objective of this study was to determine whether a combination of FNA and core biopsy (CFNACB) would yield a higher proportion of diagnostic readings compared with FNA alone in patients with a history of one or more prior nondiagnostic FNA readings. Methods We conducted a retrospective study of 90 core biopsies (CBs) performed in 82 subjects (55 women and 27 men) between 2006 and 2008 in an outpatient clinic. Results CFNACB yielded a diagnostic reading in 87%. The diagnostic reading yield of the CB component of CFNACB was significantly superior to the concurrent FNA component, with CB yielding a diagnosis in 77% of cases and FNA yielding a diagnosis in 47% (p<0.0001). The combination of CB and FNA had a higher diagnostic reading yield than either alone. In 69 nodules that had only one prior nondiagnostic FNA, CB was diagnostic in 74%, FNA was diagnostic in 52%, CFNACB was diagnostic in 87%, and CB performed significantly better than FNA (p=0.0135). In 21 nodules with two or more prior nondiagnostic FNAs, CFNACB and CB were diagnostic in 86%, FNA was diagnostic in 29%, and CB was significantly better than FNA (p=0.0005). Clinical, ultrasound, or histopathologic follow-up was available for 81% (73/90) of the CFNACB procedures. No subject with a benign CFNACB reading was diagnosed with thyroid malignancy in the follow-up period (range 4–37 months, mean 18 months), although one subject had minimal increase in nodule size and was awaiting repeat sonography at study conclusion. Conclusion Thyroid nodule CFNACB is safe and clinically useful in selected patients when a prior FNA reading is nondiagnostic. CFNACB is superior to either CB or FNA alone. CFNACB should be strongly considered as an alternative to surgery in individuals with two prior nondiagnostic FNAs. PMID:22304390

  7. Ultrasound-Guided Fine-Needle Aspiration of Non-palpable and Suspicious Axillary Lymph Nodes with Subsequent Removal after Tattooing: False-Negative Results and Concordance with Sentinel Lymph Nodes.

    PubMed

    Kim, Won Hwa; Kim, Hye Jung; Jung, Jin Hyang; Park, Ho Yong; Lee, Jeeyeon; Kim, Wan Wook; Park, Ji Young; Cheon, Hyejin; Lee, So Mi; Cho, Seung Hyun; Shin, Kyung Min; Kim, Gab Chul

    2017-11-01

    Ultrasonography-guided fine-needle aspiration (US-guided FNA) for axillary lymph nodes (ALNs) is currently used with various techniques for the initial staging of breast cancer and tagging of ALNs. With the implementation of the tattooing of biopsied ALNs, the rate of false-negative results of US-guided FNA for non-palpable and suspicious ALNs and concordance with sentinel lymph nodes were determined by node-to node analyses. A total of 61 patients with breast cancer had negative results for metastasis on US-guided FNA of their non-palpable and suspicious ALNs. The biopsied ALNs were tattooed with an injection of 1-3 mL Charcotrace (Phebra, Lane Cove West, Australia) ink and removed during sentinel lymph node biopsy or axillary dissection. We determined the rate of false-negative results and concordance with the sentinel lymph nodes by a retrospective review of surgical and pathologic findings. The association of false-negative results with clinical and imaging factors was evaluated using logistic regression. Of the 61 ALNs with negative results for US-guided FNA, 13 (21%) had metastases on final pathology. In 56 of 61 ALNs (92%), tattooed ALNs corresponded to the sentinel lymph nodes. Among the 5 patients (8%) without correspondence, 1 patient (2%) had 2 metastatic ALNs of 1 tattooed node and 1 sentinel lymph node. In multivariate analysis, atypical cells on FNA results (odds ratio = 20.7, p = 0.040) was independently associated with false-negative FNA results. False-negative ALNs after US-guided FNA occur at a rate of 21% and most of the tattooed ALNs showed concordance with sentinel lymph nodes. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration Cytology (SP-US-FNAC) Shortens Time for Diagnosis of Thyroid Nodules.

    PubMed

    Gu, Wei Xiang; Tan, Chuen Seng; Ho, Thomas W T

    2014-06-01

    Ultrasound-guided fine-needle aspiration cytology (US-FNAC) of thyroid nodules is an important diagnostic procedure. In most hospitals, patients are referred to radiologists for US-FNAC, but this often results in a long waiting time before results are available. Surgeon-performed US-FNAC (SP-US-FNAC) during the initial patient consultation attempts to reduce the waiting time but it is not known whether this is as accurate as radiologist-performed US-FNAC (RP-US-FNAC). The aim of this study is to compare the clinical efficiency between SP-US-FNAC and RP-US-FNAC. A retrospective study was performed on patients from the Department of General Surgery, Tan Tock Seng Hospital (TTSH) who underwent an US-FNAC from August 2011 to May 2012. All cases of SP-US-FNAC were performed by a single surgeon. This study compared the rates of positive diagnoses achieved by SP-US-FNAC and RPUS- FNAC as well as the time interval to reach a cytological diagnosis by each group. A total of 40 cases of SP-US-FNAC and 72 cases of RP-US-FNAC were included in the study. SP-US-FNAC resulted in 28 (70%) positive diagnoses and 12 (30%) nondiagnoses while RP-US-FNAC resulted in 47 (65.3%) positive diagnoses and 25 (34.7%) non-diagnoses. These results were comparable (P=0.678). The median time taken to reach a cytological diagnosis was 1 working day for SP-US-FNAC and 29.5 working days for RP-US-FNAC resulting in a shorter interval to reaching a cytological diagnosis for SP-US-FNAC (P<0.001). In the workup of thyroid nodules, SP-US-FNAC is as accurate as RP-US-FNAC but significantly reduces the time taken to reach a cytological diagnosis. This leads to greater clinical efficiency in the management of patients with thyroid nodules, which in turn leads to other benefits such as decreased patient anxiety and increased patient satisfaction.

  9. Development of a Tailored Thyroid Gland Phantom for Fine-Needle Aspiration Cytology by Three-Dimensional Printing.

    PubMed

    Baba, Masayuki; Matsumoto, Keitaro; Yamasaki, Naoya; Shindo, Hisakazu; Yano, Hiroshi; Matsumoto, Megumi; Otsubo, Ryota; John Lawn, Murray; Matsuo, Naoto; Yamamoto, Ikuo; Hidaka, Shigekazu; Nagayasu, Takeshi

    Fine-needle aspiration cytology (FNAC) is a challenging and risky procedure for inexperienced clinicians to perform because of the proximity of the thyroid to the jugular veins, carotid arteries, and trachea. A phantom model for transfixion practice would help train clinicians in FNAC. To fabricate a tailored phantom with consideration for authenticity of size, touch, feel, and ultrasonographic (US) characteristics. A three-dimensional (3D) digital model of the human neck was reconstructed from computed tomography data of a subject. This model was used to create 3D-printed templates for various organs that require US visualization. The templates were injected with polymers that provided similar degrees of ultrasound permeability as the corresponding organs. For fabrication of each organ, the respective molds of organs, blood vessels, thyroid gland, and tumor were injected with the material. The fabricated components were then removed from the templates and colored. Individual components were then positioned in the neck mold, and agar gel was poured in. The complete phantom was then removed from the mold. Thereafter, 45 medical doctors and students performed ultrasound-guided FNAC using the phantom, following which they were queried regarding the value of the phantom. The structure, US characteristics, and elasticity of the phantom were similar to those of the human subject. In the survey, all 45 participants replied that they found the phantom useful for FNAC training, and 30 medical students professed increased interest in thyroid diseases after using the phantom. We successfully fabricated a tailored thyroid gland phantom for transfixion practice. As most of the phantom parts are injected in molds fabricated using a 3D printer, they can be easily reproduced once the molds are fabricated. This phantom is expected to serve as an effective and fully tailored training model for practicing thyroid gland transfixion. Copyright © 2017. Published by Elsevier Inc.

  10. Cancer Localization in the Prostate with F-18 Fluorocholine Positron Emission Tomography

    DTIC Science & Technology

    2007-01-01

    INTRODUCTION Prostate cancer is the second leading cause of cancer death in American men over 50 years of age. Ultrasound - guided prostate biopsy is...currently the most common method for diagnosing and localizing cancer in the prostate. However, even when standard 6 or 12 needle biopsy templates... needles employed (1, 2). While progress has been made in the detection of primary prostate cancer using imaging techniques such as ultrasound and

  11. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  12. [On-site fine-needle aspiration cytology of thyroid nodules. Quality assurance of the Bethesda System for Reporting Thyroid Cytopathology (2008)].

    PubMed

    Bak, Mihály; Péter, Ilona; Nyári, Tibor; Simon, Péter; Újlaky, Mátyás; Boér, András; Kásler, Miklós

    2015-10-11

    The methods available for the diagnosis of thyroid nodules include physical examination, imaging, laboratory and fine-needle aspiration cytology tests. The aim of this study was to determine the quality assurance of fine-needle aspiration cytology of thyroid nodules. Cytology results were rated to 6 categories according to the Bethesda System for Reporting Thyroid Cytopathology (2008) (I. nondiagnostic; II. benign; III. atypia of undetermined significance; IV. follicular neoplasia; V. suspicious for malignancy; VI. malignant). All cytology reports were compared with the final histology diagnosis. A total of 1384 patient with thyroid nodule underwent fine-needle aspiration biopsy cytology. Smears were classified I. inadequate in 214 (15.9%); II. benign 986; III. atypical 56; IV. follicular neoplasm 41; V. suspicious for malignancy 18; VI. malignant 33 cases. Two hundred and twenty seven (16.8%) of the cases were operated and histologically verified. The positive predictive value in the benign category was 98.25% and in the malignant 88.46%. The sensitivity of the follicular neoplasm was 66.67%. The results suggest that fine-needle aspiration cytology of thyroid nodules using the Bethesda System for Reporting Thyroid Cytopathology has a high diagnostic accuracy. The auditing values of the results meet the proposed threshold values.

  13. Biological characteristics of HCC by ultrasound-guided aspiration biopsy and its clinical application

    PubMed Central

    Lin, Li-Wu; Lin, Xue-Ying; He, Yi-Mi; Gao, Shang-Da; Lin, Xiao-Dong

    2003-01-01

    AIM: To probe the pathological biological characteristics of hepatocellular carcinoma (HCC) by the ultrasound-guided aspiration biopsy and assess the clinical application value of this method. METHODS: The biopsy and DNA analysis by flow cytometry (FCM) were taken in 46 cases with HCC nodules, including 26 cases and 20 cases with nodules ≤ 3 cm and > 3 cm in diameters respectively, and 12 cases with intrahepatic benign hyperplastic nodules. They were taken in 22 cases of 46 cases with HCC before and after the therapy. Fine-needles and automatic histological incised biopsy needles were used. The fresh biopsy tissue was produced into the single cell suspension, which was sent for DNA detection and ratio analysis of cell period. The ratio of each DNA period of cell proliferation of each group was calculated and compared with each other. The DNA aneuploid (AN) and apoptosis cell peak were observed and their percentages were calculated. RESULTS: The ratios of S and G2/M periods of DNA, which reflect cell hyperproliferation, in the group with HCC tumors > 3 cm in diameter were markedly higher than those of the group with HCC nodules ≤ 3 cm in diameter and the group with the benign hyperplastic nodules (P < 0.01 except A:B of S period, P < 0.05). The ratios of the middle group were also apparently higher than those of the latter group (P < 0.01). The ratio of DNA AN of 46 cases with HCC nodules was 34.8% (16/46). None of the cases with the intrahepatic hyperplastic nodules appeared AN. The DNA AN appeared more apparently with the growth of the tumors. The AN ratio of the group with tumors > 3 cm in diameter was 55% (11/20), markedly higher than that of the group with tumors ≤ 3 cm in diameter which was 19.2% (5/26) (P < 0.01). The FCM DNA analysis of 22 specimens of hepatic carcinoma tissue before therapy showed that the aneuploid peaks appeared in 5 cases (22.7%). The ratio of G1 period rose after therapy while the S period and G2/M ratios fell (P < 0.01). The aneuploid peak disappeared in the 5 cases after the therapy, while the apoptosis peaks in 12 cases (54.5%) appeared. CONCLUSION: Addition to supply the information of the pathological morphology of the tumor, the ultrasound-guided fine-needle aspiration tissue could be sent for FCM DNA analysis to comprehend its pathological biological characteristics. This can not only provide the clinic the reliable information about the occurrence, development, diagnosis, curative effect and prognosis of tumors but also supply biological information for clinic to choose therapeutic schemes. PMID:12717834

  14. 42 CFR 411.351 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...

  15. 42 CFR 411.351 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...

  16. 42 CFR 411.351 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...

  17. Impact of axillary ultrasound and core needle biopsy on the utility of intraoperative frozen section analysis and treatment decision making in women with invasive breast cancer.

    PubMed

    Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B

    2012-09-01

    Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  19. Development of 3D ultrasound needle guidance for high-dose-rate interstitial brachytherapy of gynaecological cancers

    NASA Astrophysics Data System (ADS)

    Rodgers, J.; Tessier, D.; D'Souza, D.; Leung, E.; Hajdok, G.; Fenster, A.

    2016-04-01

    High-dose-rate (HDR) interstitial brachytherapy is often included in standard-of-care for gynaecological cancers. Needles are currently inserted through a perineal template without any standard real-time imaging modality to assist needle guidance, causing physicians to rely on pre-operative imaging, clinical examination, and experience. While two-dimensional (2D) ultrasound (US) is sometimes used for real-time guidance, visualization of needle placement and depth is difficult and subject to variability and inaccuracy in 2D images. The close proximity to critical organs, in particular the rectum and bladder, can lead to serious complications. We have developed a three-dimensional (3D) transrectal US system and are investigating its use for intra-operative visualization of needle positions used in HDR gynaecological brachytherapy. As a proof-of-concept, four patients were imaged with post-insertion 3D US and x-ray CT. Using software developed in our laboratory, manual rigid registration of the two modalities was performed based on the perineal template's vaginal cylinder. The needle tip and a second point along the needle path were identified for each needle visible in US. The difference between modalities in the needle trajectory and needle tip position was calculated for each identified needle. For the 60 needles placed, the mean trajectory difference was 3.23 +/- 1.65° across the 53 visible needle paths and the mean difference in needle tip position was 3.89 +/- 1.92 mm across the 48 visible needles tips. Based on the preliminary results, 3D transrectal US shows potential for the development of a 3D US-based needle guidance system for interstitial gynaecological brachytherapy.

  20. Usefulness of the twinkling artifact on Doppler ultrasound for the detection of breast microcalcifications.

    PubMed

    Relea, A; Alonso, J A; González, M; Zornoza, C; Bahamonde, S; Viñuela, B E; Encinas, M B

    2018-06-12

    To determine whether the twinkling artifact on Doppler ultrasound imaging corresponds to microcalcifications previously seen on mammograms and to evaluate the usefulness of this finding in the ultrasound management of suspicious microcalcifications. We used ultrasonography to prospectively examine 46 consecutive patients with groups of microcalcifications suspicious for malignancy identified at mammography, searching for the presence of the twinkling artifact to identify the microcalcifications. Once we identified the microcalcifications, we obtained core-needle biopsy specimens with 11G needles and then used X-rays to check the specimens for the presence of microcalcifications. We analyzed the percentage of detection and obtainment of microcalcifications by core-needle biopsy with this technique and the radiopathologic correlation. Microcalcifications that were not detected by ultrasound or discordant lesions were biopsied by stereotaxy at another center. We also used ultrasound guidance for preoperative marking with clips, usually orienting them radially. We identified and biopsied 41 of the 46 lesions under ultrasound guidance, including 24 of 25 carcinomas (17 in situ). B-mode ultrasound was sufficient for biopsying the microcalcifications in 14 patients, although the presence of the twinkling artifact increased the number of microcalcifications detected and thus enabled more accurate preoperative marking. Thanks to the twinkling sign, we were able to identify 27 additional groups of microcalcifications (89% vs. 30%; p < 0.05). All the surgical specimens had margins free of disease. The twinkling artifact is useful for microcalcifications in ultrasound examinations, enabling a significant increase in the yield of ultrasound-guided biopsies and better preoperative marking of groups of microcalcifications. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. The diagnostic utility of Merkel cell polyomavirus immunohistochemistry in a fine needle aspirate of metastatic Merkel cell carcinoma of unknown primary to the pancreas.

    PubMed

    Li, Long; Molberg, Kyle; Cheedella, Naga; Thibodeaux, Joel; Hinson, Stacy; Lucas, Elena

    2018-01-01

    Merkel cell carcinoma (MCC) is an aggressive skin tumor with a high tendency for metastases. We report a case of MCC initially presenting as axillary and pancreatic metastases. A 33-year-old HIV-positive Hispanic male presented with a history of a rapidly growing axillary mass. A needle core biopsy demonstrated an epithelioid neoplasm composed of small to medium-sized cells with high nuclear-cytoplasmic ratio, nuclear molding, and frequent mitotic figures. A subsequent PET scan revealed a 1.5 cm FDG avid mass in the pancreas. Endoscopic ultrasound-guided FNA of the pancreatic mass showed neoplastic cells with similar morphology to those of the axillary mass. The tumor cells were positive with pancytokeratin AE1/AE3, CK20, CD56, synatophysin, chromogranin, and Merkel cell polyomavirus (MCPyV). This case of MCC most likely originated from a resolved primary skin lesion drained by the involved axillary lymph node with subsequent metastases to the pancreas and distant lymph nodes. © 2017 Wiley Periodicals, Inc.

  2. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  3. Characterization of tissue-simulating phantom materials for ultrasound-guided needle procedures

    NASA Astrophysics Data System (ADS)

    Buchanan, Susan; Moore, John; Lammers, Deanna; Baxter, John; Peters, Terry

    2012-02-01

    Needle biopsies are standard protocols that are commonly performed under ultrasound (US) guidance or computed tomography (CT)1. Vascular access such as central line insertions, and many spinal needle therapies also rely on US guidance. Phantoms for these procedures are crucial as both training tools for clinicians and research tools for developing new guidance systems. Realistic imaging properties and material longevity are critical qualities for needle guidance phantoms. However, current commercially available phantoms for use with US guidance have many limitations, the most detrimental of which include harsh needle tracks obfuscating US images and a membrane comparable to human skin that does not allow seepage of inner media. To overcome these difficulties, we tested a variety of readily available media and membranes to evaluate optimal materials to fit our current needs. It was concluded that liquid hand soap was the best medium, as it instantly left no needle tracks, had an acceptable depth of US penetration and portrayed realistic imaging conditions, while because of its low leakage, low cost, acceptable durability and transparency, the optimal membrane was 10 gauge vinyl.

  4. Pancreatic Abscess in a cat due to Staphylococcus aureus infection.

    PubMed

    Nemoto, Yuki; Haraguchi, Tomoya; Shimokawa Miyama, Takako; Kobayashi, Kosuke; Hama, Kaori; Kurogouchi, Yosuke; Fujiki, Noriyuki; Baba, Kenji; Okuda, Masaru; Mizuno, Takuya

    2017-07-07

    A 16-year-old spayed female American Shorthair cat was presented with lethargy, anorexia, and wamble. Physical and blood examination did not reveal any remarkable findings. Abdominal ultrasonography identified the presence of a localized anechoic structure with a thick wall in contact with the small intestine and adjacent to the liver. Ultrasound-guided fine-needle aspiration of the structure revealed fluid containing numerous cocci and neutrophils. Two days after antibiotic treatment, exploratory laparotomy was performed and the content of the structure was removed before multiple lavages. The pathological and bacteriological examination results supported a confirmatory diagnosis of pancreatic abscess due to Staphylococcus aureus infection, making this the first such report in a cat. The cat remained healthy thereafter with no disease recurrence.

  5. Pancreatic cystic neoplasms: Review of current knowledge, diagnostic challenges, and management options

    PubMed Central

    Jana, Tanima; Shroff, Jennifer; Bhutani, Manoop S.

    2015-01-01

    Pancreatic cystic lesions are being detected with increasing frequency, largely due to advances in cross-sectional imaging. The most common neoplasms include serous cystadenomas, mucinous cystic neoplasms, intraductal papillary mucinous neoplasms, solid pseudopapillary neoplasms, and cystic pancreatic endocrine neoplasms. Computed tomography (CT), magnetic resonance imaging (MRI), and endoscopic ultrasound (EUS) are currently used as imaging modalities. EUS-guided fine needle aspiration has proved to be a useful diagnostic tool, and enables an assessment of tumor markers, cytology, chemistries, and DNA analysis. Here, we review the current literature on pancreatic cystic neoplasms, including classification, diagnosis, treatment, and recommendations for surveillance. Data for this manuscript was acquired via searching the literature from inception to December 2014 on PubMed and Ovid MEDLINE. PMID:25821410

  6. Male breast cancer is rare: an initial presentation may be as an abscess.

    PubMed

    Ventham, N T; Hussien, M I

    2010-08-06

    Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage.

  7. Male breast cancer is rare: an initial presentation may be as an abscess

    PubMed Central

    Ventham, N T; Hussien, M I

    2010-01-01

    Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage. PMID:22767683

  8. Sarcoidosis with Pancreatic Mass, Endobronchial Nodules, and Miliary Opacities in the Lung.

    PubMed

    Matsuura, Shun; Mochizuka, Yasutaka; Oishi, Kyohei; Miyashita, Koichi; Naoi, Hyogo; Mochizuki, Eisuke; Mikura, Shinichiro; Tsukui, Masaru; Koshimizu, Naoki; Ohata, Akihiko; Suda, Takahumi

    2017-11-15

    Sarcoidosis affects multiple organs and rarely has unusual manifestations. A 78-year-old woman was referred to our hospital for coughing symptoms. A chest computed tomography (CT) scan revealed bilateral diffuse miliary patterns and right pleural effusion. Bronchoscopy showed multiple nodules in the carina and the bronchus intermedius. A CT scan of her abdomen revealed hypovascular lesions involving the pancreatic head and body. A transbronchial lung biopsy, bronchial mucosal biopsy, and endoscopic ultrasound-guided fine-needle aspiration of the pancreatic mass demonstrated non-caseating granulomas. We diagnosed the patient with sarcoidosis. She received no treatment for sarcoidosis and has been followed up for one year, during which no pulmonary disease progression had been observed and the pancreatic masses partially regressed.

  9. SU-E-J-81: Beveled Needle Tip Detection Error in Ultrasound-Guided Prostate Brachytherapy.

    PubMed

    Leu, S; Ruiz, B; Podder, T

    2012-06-01

    To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Covington, GA) were used. The TRUS was set at 6.5MHz in water phantom at 40°C and measurements were taken with 50% and 100% TRUS gains. Needles were oriented with bevel-tip facing up (0-degree) and inserted through template grid-holes. Reference needle depths were measured when needle tip image intensity was bright enough for potentially consistent readings. High-resolution digital vernier caliper was used to measure needle depth. Needle bevel-tip orientation was then changed to bevel down (by rotating 180-degree) and needle depth was adjusted by retracting so that the needle-tip image intensity appeared similar to when the needle bevel-tip was at 0-degree orientation. Clinically relevant locations were considered for needle placement on the template grids (1st row to 9th row, and 'a-f' columns). For 50% TRUS gain, bevel tip detection errors/differences were 0.69±0.30mm (1st row) to 3.23±0.22mm (9th row) and 0.78±0.71mm (1st row) to 4.14±0.56mm (9th row) in columns 'a' and 'D', respectively. The corresponding errors for 100% TRUS gain were 0.57±0.25mm to 5.24±0.36mm and 0.84±0.30mm to 4.2±0.20mm in columns 'a' and 'D', respectively. These errors/differences varied linearly for grid-hole locations on the rows and columns in between, smaller to large depending on distance from the TRUS probe. Observed no effect of gains (50% vs. 100%) along 'D' column, which was directly above the TRUS probe. Experiment results revealed that the beveled needle tip orientation could significantly impact the detection accuracy of the needle tips, based on which the seeds might be delivered. These errors may lead to considerable dosimetric deviations in prostate brachytherapy seed implantation. © 2012 American Association of Physicists in Medicine.

  10. Primary cutaneous aspergillosis from Tamilnadu diagnosed by fine needle aspiration cytology

    PubMed Central

    Venugopal, Taralakshmi V.; Venugopal, Pankajalakshmi V.

    2012-01-01

    Aspergillus are ubiquitous and more than 30 species have been reported to be involved in human infection. Most of the cases occur in immunocompromised patients and are disseminated in the blood. Primary cutaneous aspergillosis in immunocompetent hosts is rare. We report a unique case of primary cutaneous aspergillosis in an immunocompetent patient diagnosed by fine needle aspiration cytology. The characteristic ascocarp and ascospores of Aspergillus species were found in the aspirate and Aspergillus glaucus was isolated in pure culture. The case is presented to increase the awareness of the usefulness of fine needle aspiration cytology for diagnosing fungal infections. PMID:24371752

  11. Fine-needle aspiration by vacuum tubes.

    PubMed

    Holmquist, N D

    1989-07-01

    Fine-needle aspiration of subcutaneous masses, accepted in many parts of Europe and the Americas as a routine diagnostic technique, employs a syringe holder to facilitate the creation of a vacuum to withdraw cells. This investigation demonstrates that a vacuum tube used in venipuncture can be used to supply the negative pressure to suck cells into the needle. This apparatus is more readily available than a syringe holder in hospitals and clinics, and particularly provides the operator with a more dexterous approach to the mass because the fingers holding the needle can be much closer to the mass being immobilized by the other hand.

  12. Comparison of 21-Gauge and 22-Gauge Aspiration Needle in Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E.; Ray, Cynthia; Greenhill, Sarah R.; Jimenez, Carlos A.; Filner, Joshua; Feller-Kopman, David

    2013-01-01

    Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. Methods: We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. Results: A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). Conclusions: There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle. PMID:23632441

  13. Changing attitudes toward needle biopsies of breast cancer in Shanghai: experience and current status over the past 8 years

    PubMed Central

    Hao, Shuang; Liu, Zhe-Bin; Ling, Hong; Chen, Jia-Jian; Shen, Ju-Ping; Yang, Wen-Tao; Shao, Zhi-Min

    2015-01-01

    Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were selected from the Shanghai Cancer Data base, which integrates information from approximately 50% of breast cancer patients in Shanghai. The CNB procedure uses an automated prone unit, biopsy gun, and 14-gauge needles under freehand or ultrasound guidance and was performed by experienced radiologists and surgeons specializing in needle biopsies. Diagnosis and classification for each patient were independently evaluated by pathologists. Over the indicated 8-year period, biopsy type consisted of 11,947 ultrasound-guided core needle biopsies (UCNBs), 2,015 ultrasound-guided vacuum-assisted biopsies (UVABs), and 654 stereotactic X-ray-guided vacuum-assisted biopsies (XVABs). For all the 11,947 women included in this study, image-guided needle biopsy was the initial diagnostic procedure. Approximately 81.0% of biopsied samples were histopathologically determined to be malignant lesions, 5.5% were determined to be high-risk lesions, and 13.5% were determined to be benign lesions. The number of patients choosing UCNB increased at the greatest rate, and UCNB has become a standard procedure for histodiagnosis because it is inexpensive, convenient, and accurate. The overall false-negative rate of CNB was 1.7%, and the specific false-negative rates for UCNB, UVAB, and XVAB, were 1.7%, 0%, and 0%, respectively. This study suggests that the use of preoperative needle biopsy as the initial breast cancer diagnostic procedure is acceptable in urban Shanghai. Preoperative needle biopsy is now a standard procedure in the Shanghai Cancer Center because it may reduce the number of surgeries needed to treat breast cancer. PMID:26491359

  14. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS techniques and reviews the relevant literature.

  15. Ultrasound-guided peripheral nerve blockade.

    PubMed

    Chin, Ki Jinn; Chan, Vincent

    2008-10-01

    The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.

  16. A Coaxial Dual-element Focused Ultrasound Probe for Guidance of Epidural Catheterization: An Experimental Study.

    PubMed

    Dong, Guo-Chung; Chiu, Li-Chen; Ting, Chien-Kun; Hsu, Jia-Ruei; Huang, Chih-Chung; Chang, Yin; Chen, Gin-Shin

    2017-09-01

    Ultrasound guidance for epidural block has improved clinical blind-trial problems but the design of present ultrasonic probes poses operating difficulty of ultrasound-guided catheterization, increasing the failure rate. The purpose of this study was to develop a novel ultrasonic probe to avoid needle contact with vertebral bone during epidural catheterization. The probe has a central circular passage for needle insertion. Two focused annular transducers are deployed around the passage for on-axis guidance. A 17-gauge insulated Tuohy needle containing the self-developed fiber-optic-modified stylet was inserted into the back of the anesthetized pig, in the lumbar region under the guidance of our ultrasonic probe. The inner transducer of the probe detected the shallow echo signals of the peak-peak amplitude of 2.8 V over L3 at the depth of 2.4 cm, and the amplitude was decreased to 0.8 V directly over the L3 to L4 interspace. The outer transducer could detect the echoes from the deeper bone at the depth of 4.5 cm, which did not appear for the inner transducer. The operator tilted the probe slightly in left-right and cranial-caudal directions until the echoes at the depth of 4.5 cm disappeared, and the epidural needle was inserted through the central passage of the probe. The needle was advanced and stopped when the epidural space was identified by optical technique. The needle passed without bone contact. Designs of the hollow probe for needle pass and dual transducers with different focal lengths for detection of shallow and deep vertebrae may benefit operation, bone/nonbone identification, and cost.

  17. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    NASA Astrophysics Data System (ADS)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  18. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.

  19. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

  20. Comparison of the development of performance skills in ultrasound-guided regional anesthesia simulations with different phantom models.

    PubMed

    Liu, Yang; Glass, Nancy L; Glover, Chris D; Power, Robert W; Watcha, Mehernoor F

    2013-12-01

    Ultrasound-guided regional anesthesia (UGRA) skills are traditionally obtained by supervised performance on patients, but practice on phantom models improves success. Currently available models are expensive or use perishable products, for example, olive-in-chicken breasts (OCB). We constructed 2 inexpensive phantom (transparent and opaque) models with readily available nonperishable products and compared the process of learning UGRA skills by novice practitioners on these models with the OCB model. Three experts first established criteria for a satisfactory completion of the simulated UGRA task in the 3 models. Thirty-six novice trainees (<20 previous UGRA experience) were randomly assigned to perform a UGRA task on 1 of 3 models-the transparent, opaque, and OCB models, where the hyperechoic target was identified, a needle was advanced to it under ultrasound guidance, fluid was injected, and images were saved. We recorded the errors during task completion, number of attempts and needle passes, and the time for target identification and needle placement until the predetermined benchmark of 3 consecutive successful UGRA simulations was accomplished. The number of errors, needle passes, and time for task completion per attempt progressively decreased in all 3 groups. However, failure to identify the target and to visualize the needle on the ultrasound image occurred more frequently with the OCB model. The time to complete simulator training was shortest with the transparent model, owing to shorter target identification times. However, trainees were less likely to agree strongly that this model was realistic for teaching UGRA skills. Training on inexpensive synthetic simulation models with no perishable products permits learning of UGRA skills by novices. The OCB model has disadvantages of containing potentially infective material, requires refrigeration, cannot be used after multiple needle punctures, and is associated with more failures during simulated UGRA. Direct visualization of the target in the transparent model allows the trainee to focus on needle insertion skills, but the opaque model may be more realistic for learning target identification skills required when UGRA is performed on real patients in the operating room.

  1. A Solid Pseudopapillary Tumour of the Head of Pancreas: A Rare Case Report Diagnosed by Fine Needle Aspiration Cytology

    PubMed Central

    Deshpande, Archana Hemant; Chhadi, Shyam Atmaram; Kumbhalkar, Dinkar T; Raut, Waman K

    2016-01-01

    Solid Pseudopapillary Tumour (SPPT) is a distinctive tumour of low malignant potential with a striking and unexplained predilection for adolescent girls and young women. Hence it is important to distinguish this rare tumour from other pancreatic tumours with similar cytomorphologic features because an accurate preoperative diagnosis is highly desirable since these patients can have long survival with adequate surgery. We report a case of the rare SPPT of the pancreas in a young girl who presented with nonspecific pain in the abdomen. Radiological investigations revealed a solid cystic mass in relation to the uncinate process of pancreas and third part of duodenum. The mass was diagnosed to be a solid pseudopapillary neoplasm of pancreas on ultrasound guided FNAC. Surgical removal of the pancreatic tumour and detailed histologic study confirmed the cytologic diagnosis. We present this case because, to date, there are few case reports on the cytological diagnosis of this tumour, about 60 cases, diagnosed by Fine-Needle Aspiration Cytology (FNAC) are reported in the literature. With widespread availability of high-quality imaging systems and a better understanding of its pathology, the number of cases reported in the literature has been steadily increasing in recent years. In our case, the cytological diagnosis was done even before the detailed imaging findings were available, the cytological features of this tumour are highly characteristic and it is possible to differentiate it from other pancreatic tumours with relative ease. PMID:27504299

  2. Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity

    PubMed Central

    Sconfienza, L.M.; Perrone, N.; Lacelli, F.; Lentino, C.; Serafini, G.

    2008-01-01

    Purpose Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. Method and materials The ultrasound-guided technique for BTX-A injection was used on 10 patients. The needle was inserted into the muscle belly at an angle of 45° along the longitudinal axis of the muscle when allowed by patient's condition. Results In all cases, the iliopsoas muscle was easily identified and both the iliac and psoas components were assessed. Introduction of the needle and drug injection were entirely carried out under ultrasonographic guidance. The procedure was successful in all patients, even in those with a high-grade spasticity, and general anesthesia was not required. Conclusions This ultrasound-guided technique allows accurate guidance for the injection of BTX-A, and it can be considered as an alternate supportive therapy in patients with spasticity and dystonia. PMID:23396653

  3. Core biopsy as a simple and effective diagnostic tool in head and neck focal myositis.

    PubMed

    Tan, Chun Yee; Chong, Sheldon; Shaw, Chi-Kee Leslie

    2015-12-01

    Most unilateral head and neck masses are benign, although malignancy is a possibility in some cases. However, there are other rare causes of unilateral neck masses, such as focal myositis, which is a rare, benign condition belonging to the family of inflammatory pseudotumors of the skeletal muscles, with rare presentations in the head and neck region. Focal myositis presents as a rapidly enlarging neck mass that can be misdiagnosed by fine-needle aspiration biopsy and/or radiologic imaging as either an infective or a neoplastic process. To date, there are only 5 reported cases of adult focal myositis of the sternocleidomastoid muscle in the medical literature. In this article, the authors present 2 cases involving patients with focal myositis of the sternocleidomastoid muscle that were successfully diagnosed with core-needle biopsy and managed conservatively. The pros and cons of fine-needle aspiration biopsy and core-needle biopsy are discussed. Based on the authors' results, fine-needle aspiration biopsy universally fails to provide the diagnosis of focal myositis. In contrast, core-needle biopsy successfully diagnosed focal myositis in both of our patients. Both of them had complete resolution with conservative management.

  4. Nonpalpable breast tumors: diagnosis with stereotaxic localization and fine-needle aspiration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowlatshahi, K.; Gent, H.J.; Schmidt, R.

    1989-02-01

    Modern mammography is the most effective means of detecting nonpalpable breast cancers, but correct diagnosis for malignancy is made in only 20%-30% of the cases. The conventional method of lesion localization usually results in approximate placement of the hookwire in the breast. The authors report the results of stereotaxic localization, combined with fine-needle aspiration and cytologic study, performed in 528 cases. Clinically occult breast lesions were localized precisely (within 2 mm 96% of the time), sampled by means of a 23-gauge needle, and marked with either methylene blue or a hookwire for subsequent open excisional biopsy. The results indicate amore » sensitivity of 95%, specificity of 91%, and accuracy of 92% for the fine-needle aspiration procedure. This technique offers a significantly improved preoperative method of diagnosing small breast lesions with minimal pain, no complications, reduced cost, and no disfigurement or scar interfering with subsequent mammographic follow-up.« less

  5. A-scan ultrasound system for real-time puncture safety assessment during percutaneous nephrolithotomy

    NASA Astrophysics Data System (ADS)

    Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; von Krüger, M. A.; Pereira, W. C. A.; Vilaça, João. L.

    2015-03-01

    Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.

  6. Ultrasound findings of diffuse metastasis of gastric signet-ring-cell carcinoma to the thyroid gland.

    PubMed

    Morita, Koji; Sakamoto, Takahiko; Ota, Shuji; Masugi, Hideo; Chikuta, Ikumi; Mashimo, Yamato; Edo, Naoki; Tokairin, Takuo; Seki, Nobuhiko; Ishikawa, Toshio

    2017-01-01

    It has been shown that metastases to the thyroid from extrathyroidal malignancies occur as solitary or multiple nodules, or may involve the whole thyroid gland diffusely. However, diffuse metastasis of gastric cancer to the thyroid is extremely rare. Here, we report a case of a 74-year-old woman with diffuse infiltration of gastric adenocarcinoma (signet-ring-cell carcinoma/poorly differentiated adenocarcinoma) cells in the thyroid. The pathological diagnosis was made based on upper gastrointestinal endoscopy with biopsy and fine-needle aspiration cytology of the thyroid. An 18F-FDG PET/CT revealed multiple lesions with increased uptake, including the bilateral thyroid gland. On thyroid ultrasound examination, diffuse enlargement with internal heterogeneity and hypoechoic reticular lines was observed. On color Doppler imaging, a blood-flow signal was not detected in these hypoechoic lines. These findings were similar to those of diffuse metastases caused by other primary cancers, such as lung cancer, as reported earlier. Therefore, the presence of hypoechoic reticular lines without blood-flow signals is probably common to diffuse thyroid metastasis from any origin and an important diagnostic finding. This is the first report to show detailed ultrasound findings of diffuse gastric cancer metastasis to the thyroid gland using color Doppler.

  7. American Thyroid Association statement on preoperative imaging for thyroid cancer surgery.

    PubMed

    Yeh, Michael W; Bauer, Andrew J; Bernet, Victor A; Ferris, Robert L; Loevner, Laurie A; Mandel, Susan J; Orloff, Lisa A; Randolph, Gregory W; Steward, David L

    2015-01-01

    The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging.

  8. American Thyroid Association Statement on Preoperative Imaging for Thyroid Cancer Surgery

    PubMed Central

    Bauer, Andrew J.; Bernet, Victor A.; Ferris, Robert L.; Loevner, Laurie A.; Mandel, Susan J.; Orloff, Lisa A.; Randolph, Gregory W.; Steward, David L.

    2015-01-01

    Background: The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Summary: Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging. PMID:25188202

  9. Extent of surgery for papillary thyroid cancer: preoperative imaging and role of prophylactic and therapeutic neck dissection.

    PubMed

    Cisco, Robin M; Shen, Wen T; Gosnell, Jessica E

    2012-03-01

    Papillary thyroid cancer (PTC) has an excellent prognosis, yet lymph node metastases are common. Most authors agree that central and/or lateral lymph node dissection should be undertaken in patients with abnormal lymph nodes detected on ultrasound, physical examination or intraoperative inspection. However the appropriate extent of prophylactic lymph node dissection for clinically node-negative patients remains the subject of controversy. There have been no randomized trials to date to offer guidance on this issue. The 2006 guidelines of the American Thyroid Association recommended consideration of prophylactic bilateral central lymph node dissection (CLND) for all patients undergoing thyroidectomy for PTC. However, the absence of compelling evidence for a benefit in terms of recurrence or survival, and the potential for increased morbidity, have led many, including our institution, to take an approach of selective central lymph node dissection. This approach is guided by the detection of abnormal lymph nodes on preoperative ultrasound, on physical examination, or during surgery. Postoperatively, ultrasound by an experienced ultrasonographer is the mainstay of evaluation for lymph node recurrence and is combined with monitoring of thyroglobulin and antithyroglobulin antibody levels. Reoperative lymph node dissection is typically undertaken upon detection and fine needle aspiration (FNA) of involved lymph nodes 0.8 cm or greater in size.

  10. Thyroid Ultrasound Pitfalls: Esophageal Fibrovascular Polyp Mimicking Thyroid Nodule

    PubMed Central

    Brigante, G.; Madeo, B.

    2016-01-01

    Background. Ultrasound (US) is the most accurate tool in the diagnosis of thyroid nodules if performed by expert physician. Misdiagnosis due to extrathyroidal lesions mimicking thyroid nodules is reported in literature. We describe the first case of an esophageal fibrovascular polyp misdiagnosed as a thyroid nodule on US examination. Patient Findings. A 54-year-old woman presented to emergency department for headache and underwent carotid Doppler extended to neck ultrasound with incidental finding of a nodule in the posterior side of the left thyroid lobe. A following thyroid US performed by an endocrinologist allowed the characterization of the lesion as an esophageal pathology, considering the extrathyroidal position, the typical peripheral hyperechoic spots and hypoechoic rim, the connection to the esophagus, and the swallowing connected movement. The patient was addressed to further investigations and finally to anterior pharyngotomy with histological diagnosis of esophageal fibrovascular polyp. Summary. Differential diagnosis between thyroid nodules and other neck lesions is important to prevent an unnecessary fine needle aspiration biopsy and to treat the extrathyroidal pathology. In this case, an US performed by an expert endocrinologist allowed detecting an esophageal fibrovascular polyp requiring surgical removal. In conclusion, the possibility of an esophageal pathology, and even fibrovascular polyp, should be considered during US thyroid examination. PMID:27022492

  11. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    PubMed

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect needle visibility. We found that the use of Infiniti Plus decreased the median time to successfully place a femoral nerve catheter by 33% compared with not using Infiniti Plus. This difference may be more apparent to clinicians undertaking this procedure less often or by those in training as our team was very experienced, had been trained in the technique and was working in a hospital with a large caseload. Clinicaltrials.gov identifier: NCT02080481.

  12. Reverse transcriptase polymerase chain reaction on fine needle aspirates for rapid detection of translocations in synovial sarcoma.

    PubMed

    Nilsson, G; Wang, M; Wejde, J; Kanter, L; Karlén, J; Tani, E; Kreicbergs, A; Larsson, O

    1998-01-01

    To evaluate the utilization of fine needle aspiration (FNA) biopsy to obtain material for reverse-transcriptase polymerase chain reaction (RT-PCR) in the detection of the t(X;18)(p11.2;q11.2) translocation in synovial sarcomas. We applied RT-PCR to detection of synovial sarcoma fusion gene transcripts on fine needle aspirates. Five clinical samples were first analyzed: one was a tumor previously diagnosed as malignant hemangiopericytoma, one was a poorly defined tumor, and three were suspected synovial sarcomas. FNA material was transferred directly to the RT-PCR reaction tube without RNA extraction. The t(X;18) translocation could be detected on the limited amount of material that FNA provides. In each of the cases studied the representivity of the tumor samples was confirmed microscopically. Our protocol permits analysis directly on representative samples without extraction of RNA. The results imply that RT-PCR offers reliable detection of sarcoma fusion gene transcripts on fine needle aspirates. The procedure, apart from being applicable to outpatients, is rapid and sensitive.

  13. [Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules].

    PubMed

    Bak, Mihály; Hidvégi, Judit; Andi, Judit; Bahéry, Mária; Kovács, Eszter; Schneider, Ferenc; Kostic, Szilárd; Rényi-Vámos, Ferenc; Szőke, János; Nyári, Tibor; Gődény, Mária; Kásler, Miklós

    2013-01-06

    The methods available for the diagnosis of lung cancer include radiologic, cytologic and pathologic procedures. The aim of this study was to determine the quality assurance of CT guided fine needle aspiration cytology of lung nodules. Cytology results were rated to 4 categories (positive; suspicious; negative; not representative). All cytology reports were compared with the final histology diagnosis. A total of 128 patients underwent CT-guided percutaneous fine-needle aspiration biopsy cytology (63 males; 65 females; mean age 62.8 years). Smears were adequate in 99 cases and inadequate in 29 cases. The average diameter of the nodules was 3.28 cm. Thirty three (25.6%) of the cases were histologically verified and 2 falsely negative and 2 falsely positive cases were detected. The sensitivity and the positive predictive value were 88.8% and 88.8%, respectively. Pneumothorax developed in 7 (5.4%) cases. These results suggest that CT-guided transthoracic fine needle aspiration cytology has a high diagnostic accuracy and an acceptable complication rate. The auditing valves of the results meet the proposed threshold values.

  14. Detection of comorbidities and synchronous primary tumours via thoracic radiography and abdominal ultrasonography and their influence on treatment outcome in dogs with soft tissue sarcomas, primary brain tumours and intranasal tumours.

    PubMed

    Bigio Marcello, A; Gieger, T L; Jiménez, D A; Granger, L Abbigail

    2015-12-01

    Canine soft tissue sarcomas (STS), primary brain tumours and intranasal tumours are commonly treated with radiotherapy (RT). Given the low metastatic potential of these tumours, recommendations regarding imaging tests as staging are variable among institutions. The purpose of our study was to describe thoracic radiographic and abdominal ultrasonographic findings in dogs with these neoplasms and to investigate association of abnormal findings with alterations in recommended treatment. Medical records from 101 dogs, each having thoracic radiographs and abdominal ultrasound performed as part of their staging, were reviewed. In 98 of 101 (97%), imaging abnormalities were detected, 27% of which were further investigated with fine needle aspiration cytology or biopsy. Nine percent of the detected abnormalities were considered serious comorbidities that altered treatment recommendations, including 3 (3%) which were confirmed as synchronous primary neoplasms. These findings may influence recommendations regarding the decision to perform thoracic radiographs and abdominal ultrasound prior to initiation of RT. © 2013 John Wiley & Sons Ltd.

  15. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy.

    PubMed

    Naqvi, Hanna; Edhi, Muhammad Muzzammil; Aslam, Hafiz Muhammad; Faridi, Naveen

    2013-02-12

    Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis.

  16. An alternative and inexpensive percutaneous access needle in pediatric patients.

    PubMed

    Penbegul, Necmettin; Soylemez, Haluk; Bozkurt, Yasar; Sancaktutar, Ahmet Ali; Bodakci, Mehmet Nuri; Hatipoglu, Namik Kemal; Atar, Murat; Yildirim, Kadir

    2012-10-01

    The most important factor that increases the cost of percutaneous surgery is the disposable instruments used for the surgery. In this study we present the advantages of using an intravenous cannula instead of a percutaneous access needle for renal access. Recently, percutaneous stone surgery has grown in use in pediatric cases and is considered a minimally invasive surgery. The most important step in this surgery is access to the renal collecting systems. Although fluoroscopy has been used frequently at this stage, the use of ultrasound has recently increased. During percutaneous accesses under all types of imaging techniques, disposable 11- to 15-cm-long 18-ga needles are used. In pediatric cases, these longer needles are difficult to use. Using disposable materials in percutaneous nephrolithotomy increases the cost of the procedure. Therefore, we asserted that percutaneous access especially in pediatric cases could be performed using a 16-ga intravenous cannula (angiocath). Indeed, percutaneous access was performed successfully, especially in pediatric preschool patients. Shorter needle length, easy skin entry, comfort of manipulation, clear visualization of the metal needle on ultrasound, and wide availability can be considered advantages of this method. The angiocath is also less expensive than a percutaneous access needle. Angiocath is inexpensive, easily available, and practical, and it is the shortest needle to perform percutaneous access in pediatric patients. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. [Percutaneous renal puncture guide by a novel real-time needle-tracking ultrasound system for percutaneous nephrolithotomy: analysis of 16 cases].

    PubMed

    Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng

    2014-08-18

    To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.

  18. Retrobulbar pigmented peripheral nerve sheath tumor in a dog.

    PubMed

    Curto, Elizabeth; Clode, Alison B; Durrant, Jessica; Montgomery, Keith W; Gilger, Brian C

    2016-11-01

    A 1-year-old male castrated Pug was referred for unilateral exophthalmos unresponsive to oral antibiotic and anti-inflammatory therapy. Clinical findings included exophthalmos of the left eye with lateral strabismus, resistance to retropulsion, and an elevated nictitans. Hematologic and biochemical analyses were within normal limits. Findings following computed tomography (CT) of the head included an expansile retrobulbar soft tissue mass with bony lysis extending into the left nasal cavity and nasopharynx. Ultrasound-guided fine-needle aspirates and biopsy samples obtained via rhinoscopy were nondiagnostic. Palliative exenteration was elected; the patient was euthanized 13 weeks following exenteration due to development of neurologic signs and perceived poor quality of life. The histopathologic diagnosis was a malignant pigmented peripheral nerve sheath tumor. © 2015 American College of Veterinary Ophthalmologists.

  19. Development of a Novel Ultrasound-guided Peritonsillar Abscess Model for Simulation Training.

    PubMed

    Ng, Vivienne; Plitt, Jennifer; Biffar, David

    2018-01-01

    Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments.1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition.6-9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. Forty-six emergency medicine (EM) residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41). They found the model realistic (mean 3.73) and easy to use (mean 4.08). Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing on the trainer. This low-cost, easy-to-construct simulator allows for ultrasound image acquisition while performing PTA needle aspirations and is the first reported of its kind. Educators from EM and otolaryngology can use this model to educate inexperienced trainees, thus ultimately improving patient safety in the clinical setting.

  20. Ultrasound-Guided Cryoanalgesia of Peripheral Nerve Lesions.

    PubMed

    Djebbar, Sahlya; Rossi, Ignacio M; Adler, Ronald S

    2016-11-01

    The real-time nature of ultrasound makes it ideally suited to provide guidance for a variety of musculoskeletal interventional procedures involving peripheral nerves. Continuous observation of the needle ensures proper placement and allows continuous monitoring when performing localized ablative therapy and therefore more accurate positioning of a cryoprobe, use of smaller needles, as well as access to small structures. We describe our experience performing cryoablative procedures. Patients undergoing cryoneurolysis have largely reported varying degrees of long-term pain relief and improvement in function; no serious complications have yet been identified. Ultrasound-guided cryoneurolysis can provide a useful, safe alternative to other ablative techniques to achieve long-term analgesia from painful peripheral nerve lesions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Ultrasound-guided core biopsy in the diagnosis of lymphoma of the head and neck. A 9 year experience

    PubMed Central

    Burke, C; Thomas, R; Inglis, C; Baldwin, A; Ramesar, K; Grace, R; Howlett, D C

    2011-01-01

    Objectives This retrospective study aimed to evaluate the diagnostic utility of ultrasound-guided core biopsy (USCB) in lymphoma of the head and neck, in particular whether core biopsy can provide sufficient diagnostic information for definitive treatment. Methods All lymphomas diagnosed in the head and neck at Eastbourne General Hospital between January 2000 and June 2009 were identified. Radiology and pathology reports were reviewed and the diagnostic techniques recorded. The type of biopsy (fine needle aspiration, needle core, surgical excision biopsy) used to establish a diagnosis sufficient to allow treatment, i.e. the "index" diagnostic technique, was identified. Previous inconclusive or inadequate biopsies were noted. Pathology reports based on USCB were graded 0–3 according to diagnostic completeness and ability to provide treatment information. Results Of 691 overall cases of lymphoma diagnosed over the 9 year period, 171 different patients presented with lymphoma in the head and neck. Of these 171, 83 had USCB biopsy during diagnostic work up. 60 were regarded as grade 3 where a confident diagnosis of lymphoma was made. In seven patients, clinical management proceeded on the basis of a suggestive (grade 2) pathology report without surgical excision, and these were therefore also included as "index" biopsies. Overall therefore, 67/83 core biopsies (81%) provided adequate information to allow treatment. Surgical excision biopsy was the index modality in 104 cases. Conclusion In the majority of cases USCB is adequate for confident histopathological diagnosis avoiding the need for surgical excision biopsy in cases of suspected head and neck lymphoma. PMID:21427181

  2. Determining procedures for simulation-based training in radiology: a nationwide needs assessment.

    PubMed

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars

    2018-06-01

    New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.

  3. Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine

    NASA Astrophysics Data System (ADS)

    Rasoulian, Abtin; Rohling, Robert N.; Abolmaesumi, Purang

    2012-02-01

    The placement of an epidural needle is among the most difficult regional anesthetic techniques. Ultrasound has been proposed to improve success of placement. However, it has not become the standard-of-care because of limitations in the depictions and interpretation of the key anatomical features. We propose to augment the ultrasound images with a registered statistical shape model of the spine to aid interpretation. The model is created with a novel deformable group-wise registration method which utilizes a probabilistic approach to register groups of point sets. The method is compared to a volume-based model building technique and it demonstrates better generalization and compactness. We instantiate and register the shape model to a spine surface probability map extracted from the ultrasound images. Validation is performed on human subjects. The achieved registration accuracy (2-4 mm) is sufficient to guide the choice of puncture site and trajectory of an epidural needle.

  4. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    PubMed

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  5. Thoracic ultrasound-assisted selection for pleural biopsy with Abrams needle.

    PubMed

    Botana-Rial, Maribel; Leiro-Fernández, Virginia; Represas-Represas, Cristina; González-Piñeiro, Ana; Tilve-Gómez, Amara; Fernández-Villar, Alberto

    2013-11-01

    Closed pleural biopsy (CPB) in patients with malignant pleural effusion is less sensitive than cytology. Ultrasound-assisted CPB allows biopsies to be performed in the lower thoracic parietal pleura, where secondary spread from pleural metastases is initially more likely to be found. We analyzed whether choosing the point of entry for CPB with thoracic ultrasound assistance influences the diagnostic yield in malignant pleural effusion. This prospective study included patients who underwent CPB performed by an experienced pulmonologist in 2008-2010 (group A) and thoracic ultrasound was used to select the biopsy site. The results were compared with a historical series of CPB performed by the same pulmonologist without the assistance of thoracic ultrasound (group B). An Abrams needle was used in all cases. We analyzed the obtaining of pleural tissue and the diagnostic yield. We included 114 CPBs from group A (23% tuberculous pleural effusion, 27% malignant pleural effusion) and 67 CPBs from group B (24% tuberculous pleural effusion, 30% malignant pleural effusion) (P = .70). Pleural tissue was obtained in 96.5% of the group A CPBs and 89.6% of the group B CPBs (P = .05). The diagnostic yields of CPB for tuberculous pleural effusion and malignant pleural effusion in group A were 89.5% and 77.4%, respectively, and 91.7% and 60%, respectively, in group B (P = .80 for tuberculous pleural effusion, and P = .18 for malignant pleural effusion). Selecting the point of entry for CPB using thoracic ultrasound increases the likelihood of obtaining pleural tissue and the diagnostic yield, but without statistical significance. We recommend ultrasound-assisted CPB to investigate pleural effusion, since the diagnostic yield of a pleural biopsy with an Abrams needle increased by > 17% in subjects with malignant pleural effusion.

  6. [Value of ultrasonically-guided liver puncture biopsy in the diagnosis of primary liver cancer. Apropos of 84 cases].

    PubMed

    Peghini, M; Eynard, J P; Vergne, R; Seurat, P; Barabe, P; Aubry, P; Diallo, A; Gueye, P M

    1987-01-01

    Ultrasonographicaly guided fine needle aspiration of liver was performed in 84 patients having a confirmed HCC. This technics utilizes a CHIBA type fine needle, after blood coagulation tests have been checked. Out of 84 fine needle aspirations performed: 64 were positive (76,2%), 9 negative (10,7%), 11 (13,19%) were questionable (6) or nonanalysable (5). It is ascertained that the sensibility of this technics is over 75%. It should be possible to improve it by repeating such an exam in previously negative patients. The causes of failure are discussed. Tolerance of the technics is good. It is attraumatic, and of very easily performance. No accident, no mishap was noted.

  7. Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry.

    PubMed

    Yarmus, Lonny B; Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E; Ray, Cynthia; Greenhill, Sarah R; Jimenez, Carlos A; Filner, Joshua; Feller-Kopman, David

    2013-04-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle.

  8. Feasibility of ultrasound-guided epidural access at the lumbo-sacral space in dogs.

    PubMed

    Liotta, Annalisa; Busoni, Valeria; Carrozzo, Maria Valentina; Sandersen, Charlotte; Gabriel, Annick; Bolen, Géraldine

    2015-01-01

    Epidural injections are commonly performed blindly in veterinary medicine. The aims of this study were to describe the lumbosacral ultrasonographic anatomy and to assess the feasibility of an ultrasound-guided epidural injection technique in dogs. A cross sectional anatomic atlas of the lumbosacral region and ex vivo ultrasound images were obtained in two cadavers to describe the ultrasound anatomy and to identify the landmarks. Sixteen normal weight canine cadavers were used to establish two variations of the technique for direct ultrasound-guided injection, using spinal needles or epidural catheters. The technique was finally performed in two normal weight cadavers, in two overweight cadavers and in five live dogs with radiographic abnormalities resulting of the lumbosacral spine. Contrast medium was injected and CT was used to assess the success of the injection. The anatomic landmarks to carry out the procedure were the seventh lumbar vertebra, the iliac wings, and the first sacral vertebra. The target for directing the needle was the trapezoid-shaped echogenic zone between the contiguous articular facets of the lumbosacral vertebral canal visualized in a parasagittal plane. The spinal needle or epidural catheter was inserted in a 45° craniodorsal-caudoventral direction through the subcutaneous tissue and the interarcuate ligament until reaching the epidural space. CT examination confirmed the presence of contrast medium in the epidural space in 25/25 dogs, although a variable contamination of the subarachnoid space was also noted. Findings indicated that this ultrasound-guided epidural injection technique is feasible for normal weight and overweight dogs, with and without radiographic abnormalities of the spine. © 2014 American College of Veterinary Radiology.

  9. Comparison of the therapeutic effects of ultrasound-guided platelet-rich plasma injection and dry needling in rotator cuff disease: a randomized controlled trial.

    PubMed

    Rha, Dong-wook; Park, Gi-Young; Kim, Yong-Kyun; Kim, Min Tae; Lee, Sang Chul

    2013-02-01

    To compare the effects of platelet-rich plasma injection with those of dry needling on shoulder pain and function in patients with rotator cuff disease. A single-centre, prospective, randomized, double-blinded, controlled study. University rehabilitation hospital. Thirty-nine patients with a supraspinatus tendon lesion (tendinosis or a partial tear less than 1.0 cm, but not a complete tear) who met the inclusion criteria recruited between June 2010 and February 2011. Two dry needling procedures in the control group and two platelet-rich plasma injections in the experimental group were applied to the affected shoulder at four-week intervals using ultrasound guidance. The Shoulder Pain and Disability Index, passive range of motion of the shoulder, a physician global rating scale at the six-month follow-up, adverse effects monitoring and an ultrasound measurement were used as outcome measures. The clinical effect of the platelet-rich plasma injection was superior to the dry needling from six weeks to six months after initial injection (P < 0.05). At six months the mean Shoulder Pain and Disability Index was 17.7 ± 3.7 in the platelet-rich plasma group versus 29.5 ± 3.8 in the dry needling group (P < 0.05). No severe adverse effects were observed in either group. Autologous platelet-rich plasma injections lead to a progressive reduction in the pain and disability when compared to dry needling. This benefit is certainly still present at six months after treatment. These findings suggest that treatment with platelet-rich plasma injections is safe and useful for rotator cuff disease.

  10. A comparison of needle tip localization accuracy using 2D and 3D trans-rectal ultrasound for high-dose-rate prostate cancer brachytherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Hrinivich, W. Thomas; Hoover, Douglas A.; Surry, Kathleen; Edirisinghe, Chandima; Montreuil, Jacques; D'Souza, David; Fenster, Aaron; Wong, Eugene

    2016-03-01

    Background: High-dose-rate brachytherapy (HDR-BT) is a prostate cancer treatment option involving the insertion of hollow needles into the gland through the perineum to deliver a radioactive source. Conventional needle imaging involves indexing a trans-rectal ultrasound (TRUS) probe in the superior/inferior (S/I) direction, using the axial transducer to produce an image set for organ segmentation. These images have limited resolution in the needle insertion direction (S/I), so the sagittal transducer is used to identify needle tips, requiring a manual registration with the axial view. This registration introduces a source of uncertainty in the final segmentations and subsequent treatment plan. Our lab has developed a device enabling 3D-TRUS guided insertions with high S/I spatial resolution, eliminating the need to align axial and sagittal views. Purpose: To compare HDR-BT needle tip localization accuracy between 2D and 3D-TRUS. Methods: 5 prostate cancer patients underwent conventional 2D TRUS guided HDR-BT, during which 3D images were also acquired for post-operative registration and segmentation. Needle end-length measurements were taken, providing a gold standard for insertion depths. Results: 73 needles were analyzed from all 5 patients. Needle tip position differences between imaging techniques was found to be largest in the S/I direction with mean+/-SD of -2.5+/-4.0 mm. End-length measurements indicated that 3D TRUS provided statistically significantly lower mean+/-SD insertion depth error of -0.2+/-3.4 mm versus 2.3+/-3.7 mm with 2D guidance (p < .001). Conclusions: 3D TRUS may provide more accurate HDR-BT needle localization than conventional 2D TRUS guidance for the majority of HDR-BT needles.

  11. Thermal comparison of Infiniti OZil and Signature Ellips phacoemulsification systems.

    PubMed

    Schmutz, Joseph S; Olson, Randall J

    2010-05-01

    To determine thermal characteristics of Signature Ellips (Abbott Medical Optics) and Infiniti OZil (Alcon, Inc.) transverse ultrasound and compare both with longitudinal ultrasound in clinically relevant scenarios. Laboratory investigation. Temperature increase over baseline after 60 seconds was measured in water at positions in 90-degree increments around the sleeve near the proximal needle shaft in an artificial chamber for Ellips and OZil on continuous ultrasound with aspiration blocked and unblocked. This was also done with Signature using longitudinal ultrasound, with and without micropulse (6 ms on, 12 ms off), with aspiration blocked and unblocked, and at the OZil sleeve tip on continuous transverse mode with aspiration unblocked. OZil (8.1 +/- 0.3 C) had greater temperature increase than Ellips (5.2 +/- 0.3 C; P < .0001) with aspiration unblocked and blocked (29.3 +/- 1.0 C vs 12.2 +/- 0.7 C; P < .0001). OZil had uneven distribution of heat around the shaft (30.1 +/- 0.5 C vs 28.5 +/- 0.6 C; P < .0001), whereas Ellips did not (P = .57). OZil was cooler at the tip (6.6 +/- 0.2 C; P < .0001). Friction in a cadaver eye incision only increased these numbers by 10% (OZil, irrigation blocked). Metal stress probably creates heat at the proximal needle junction for both transverse methods. Heat generation differences between OZil and Ellips result from the manner in which they create needle motion. Incision burns may occur, especially for OZil, under nonpulsed settings during fragment removal with occlusion when reaching across the anterior chamber such that the proximal needle shaft came near the wound. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Litter type control on soil C and N stabilization dynamics in a temperate forest.

    PubMed

    Hatton, Pierre-Joseph; Castanha, Cristina; Torn, Margaret S; Bird, Jeffrey A

    2015-03-01

    While plant litters are the main source of soil organic matter (SOM) in forests, the controllers and pathways to stable SOM formation remain unclear. Here, we address how litter type ((13) C/(15) N-labeled needles vs. fine roots) and placement-depth (O vs. A horizon) affect in situ C and N dynamics in a temperate forest soil after 5 years. Litter type rather than placement-depth controlled soil C and N retention after 5 years in situ, with belowground fine root inputs greatly enhancing soil C (x1.4) and N (x1.2) retention compared with aboveground needles. While the proportions of added needle and fine root-derived C and N recovered into stable SOM fractions were similar, they followed different transformation pathways into stable SOM fractions: fine root transfer was slower than for needles, but proportionally more of the remaining needle-derived C and N was transferred into stable SOM fractions. The stoichiometry of litter-derived C vs. N within individual SOM fractions revealed the presence at least two pools of different turnover times (per SOM fraction) and emphasized the role of N-rich compounds for long-term persistence. Finally, a regression approach suggested that models may underestimate soil C retention from litter with fast decomposition rates. © 2014 John Wiley & Sons Ltd.

  13. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy

    PubMed Central

    2013-01-01

    Background Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. Methodology It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. Results A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). Conclusion CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis. PMID:23402220

  14. Maximizing the endosonography: The role of contrast harmonics, elastography and confocal endomicroscopy.

    PubMed

    Seicean, Andrada; Mosteanu, Ofelia; Seicean, Radu

    2017-01-07

    New technologies in endoscopic ultrasound (EUS) evaluation have been developed because of the need to improve the EUS and EUS-fine needle aspiration (EUS-FNA) diagnostic rate. This paper reviews the principle, indications, main literature results, limitations and future expectations for each of the methods presented. Contrast-enhanced harmonic EUS uses a low mechanical index and highlights slow-flow vascularization. This technique is useful for differentiating solid and cystic pancreatic lesions and assessing biliary neoplasms, submucosal neoplasms and lymph nodes. It is also useful for the discrimination of pancreatic masses based on their qualitative patterns; however, the quantitative assessment needs to be improved. The detection of small solid lesions is better, and the EUS-FNA guidance needs further research. The differentiation of cystic lesions of the pancreas and the identification of the associated malignancy features represent the main indications. Elastography is used to assess tissue hardness based on the measurement of elasticity. Despite its low negative predictive value, elastography might rule out the diagnosis of malignancy for pancreatic masses. Needle confocal laser endomicroscopy offers useful information about cystic lesions of the pancreas and is still under evaluation for use with solid pancreatic lesions of lymph nodes.

  15. CASPER: computer-aided segmentation of imperceptible motion-a learning-based tracking of an invisible needle in ultrasound.

    PubMed

    Beigi, Parmida; Rohling, Robert; Salcudean, Septimiu E; Ng, Gary C

    2017-11-01

    This paper presents a new micro-motion-based approach to track a needle in ultrasound images captured by a handheld transducer. We propose a novel learning-based framework to track a handheld needle by detecting microscale variations of motion dynamics over time. The current state of the art on using motion analysis for needle detection uses absolute motion and hence work well only when the transducer is static. We have introduced and evaluated novel spatiotemporal and spectral features, obtained from the phase image, in a self-supervised tracking framework to improve the detection accuracy in the subsequent frames using incremental training. Our proposed tracking method involves volumetric feature selection and differential flow analysis to incorporate the neighboring pixels and mitigate the effects of the subtle tremor motion of a handheld transducer. To evaluate the detection accuracy, the method is tested on porcine tissue in-vivo, during the needle insertion in the biceps femoris muscle. Experimental results show the mean, standard deviation and root-mean-square errors of [Formula: see text], [Formula: see text] and [Formula: see text] in the insertion angle, and 0.82, 1.21, 1.47 mm, in the needle tip, respectively. Compared to the appearance-based detection approaches, the proposed method is especially suitable for needles with ultrasonic characteristics that are imperceptible in the static image and to the naked eye.

  16. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.

    2017-03-01

    Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.

  17. Automatic needle segmentation in 3D ultrasound images using 3D Hough transform

    NASA Astrophysics Data System (ADS)

    Zhou, Hua; Qiu, Wu; Ding, Mingyue; Zhang, Songgeng

    2007-12-01

    3D ultrasound (US) is a new technology that can be used for a variety of diagnostic applications, such as obstetrical, vascular, and urological imaging, and has been explored greatly potential in the applications of image-guided surgery and therapy. Uterine adenoma and uterine bleeding are the two most prevalent diseases in Chinese woman, and a minimally invasive ablation system using an RF button electrode which is needle-like is being used to destroy tumor cells or stop bleeding currently. Now a 3D US guidance system has been developed to avoid accidents or death of the patient by inaccurate localizations of the electrode and the tumor position during treatment. In this paper, we described two automated techniques, the 3D Hough Transform (3DHT) and the 3D Randomized Hough Transform (3DRHT), which is potentially fast, accurate, and robust to provide needle segmentation in 3D US image for use of 3D US imaging guidance. Based on the representation (Φ , θ , ρ , α ) of straight lines in 3D space, we used the 3DHT algorithm to segment needles successfully assumed that the approximate needle position and orientation are known in priori. The 3DRHT algorithm was developed to detect needles quickly without any information of the 3D US images. The needle segmentation techniques were evaluated using the 3D US images acquired by scanning water phantoms. The experiments demonstrated the feasibility of two 3D needle segmentation algorithms described in this paper.

  18. Ultrasound guided fine-needle aspiration biopsy of thyroid nodules: Guidelines and recommendations vs clinical practice; a 12-month study of 89 patients.

    PubMed

    Peli, M; Capalbo, E; Lovisatti, M; Cosentino, M; Berti, E; Mattai Dal Moro, R; Cariati, M

    2012-06-01

    Given the high prevalence of thyroid nodules in the general population it is essential to develop a method for identifying those nodules which require fine-needle aspiration biopsy (FNAB) due to suspicion for malignancy in order to avoid over- or under treatment of this disease. The ultrasound (US) criteria identified by Kim et al. and the American Association of Clinical Endocrinologists appear to be the most sensitive and most specific. The purpose of this study was to analyze a sample of patients who underwent FNAB of the thyroid and to compare the obtained data with the international guidelines and the recommendations for management of thyroid nodules. This study analyzed the clinical, anamnestic and US reasons for which 97 nodules located in 89 patients underwent FNAB, and the data were compared with the criteria set by the guidelines and with the cytological results. Echogenicity was indication for FNAB in 99% of cases, appearance of the margins in 75.3%, presence of calcifications in 93.8% and presence of vascularity in 73.2%. In a total of 4.1% of cases, cytological outcome was positive for malignancy, 21.6% necessitated monitoring, 4.1% were referred to surgery and histological examination of the surgical specimen and 63.9% resulted negative for malignancy. The finding of hypoechoic nodules often leads to continued investigation; the presence of intranodular vascularization detected at Doppler US is perceived as suspicious and the presence of microcalcifications always leads to further investigation. On the request of the endocrinologist the dominant nodule in a goiter is in most cases subjected to FNAB even if the volume has not increased. Adequate US criteria can help identify potentially malignant nodules and guide implementation of FNAB. However, identification of malignant nodules using instrumental investigation cannot disregard medical records and clinical laboratory tests. According to the authors' experience, a close collaboration between endocrinologists, radiologists and pathologists is essential for a correct evaluation of patients with thyroid nodules in order to avoid over or under estimation of the risk of malignancy of a nodule and therefore of the necessity to perform further examinations.

  19. Effect of the time of day and queue position in the endoscopic schedule on the performance characteristics of endoscopic ultrasound-guided fine-needle aspiration for diagnosing pancreatic malignancies

    PubMed Central

    Korenblit, Jason; Tholey, Danielle M.; Tolin, Joanna; Loren, David; Kowalski, Thomas; Adler, Douglas G.; Davolos, Julie; Siddiqui, Ali A.

    2016-01-01

    Background and Objectives: Recent reports have indicated that the time of day may impact the detection rate of abnormal cytology on gynecologic cytology samples. The aim of this study was to determine if procedure time or queue position affected the performance characteristics of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosing solid pancreatic malignancies. Patients and Methods: We conducted a retrospective study evaluating patients with solid pancreatic lesions in whom EUS-FNA was performed. Three timing variables were evaluated as surrogate markers for endoscopist fatigue: Procedure start times, morning versus afternoon procedures, and endoscopy queue position. Statistical analyses were performed to determine whether the timing variables predicted performance characteristics of EUS-FNA. Results: We identified 609 patients (mean age: 65.8 years, 52.1% males) with solid pancreatic lesions who underwent EUS-FNA. The sensitivity of EUS-FNA was 100% for procedures that started at 7 AM while cases that started at 4 PM had a sensitivity of 81%. Using start time on a continuous scale, each elapsed hour was associated with a 1.9% decrease in EUS-FNA sensitivity (P = 0.003). Similarly, a 10% reduction in EUS-FNA sensitivity was detected between morning and afternoon procedures (92% vs. 82% respectively, P = 0.0006). A linear regression comparing the procedure start time and diagnostic accuracy revealed a decrease of approximately 1.7% in procedure accuracy for every hour later a procedure was started. A 16% reduction in EUS-FNA accuracy was detected between morning and afternoon procedures (100% vs. 84% respectively, P = 0.0009). When the queue position was assessed, a 2.4% reduction in accuracy was noted for each increase in the queue position (P = 0.013). Conclusion: Sensitivity and diagnostic accuracy of EUS-FNA for solid pancreatic lesions decline with progressively later EUS starting times and increasing numbers of procedures before a given EUS, potentially from endoscopist fatigue and cytotechnologist fatigue. PMID:27080605

  20. Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis

    DTIC Science & Technology

    2012-06-01

    can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study are (1) light...which collect light scattering and auto-fluorescence from the prostate tissue, into a transrectal- ultrasound , needle - biopsy probe. In the...probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study were

  1. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Using 19-G Needle for Sarcoidosis.

    PubMed

    Balwan, Akshu

    2018-05-16

    Flexible bronchoscopy with endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is increasingly being used to obtain pathology specimens for diagnosis of sarcoidosis. There is wide variation in reported diagnostic yield in literature. New TBNA needles are available in the market but data are lacking about their diagnostic yield especially for sarcoidosis. This study reports the diagnostic yield of bronchoscopy with EBUS-TBNA using ViziShot FLEX 19-G needle in a series of patients with suspected sarcoidosis. This is a retrospective chart review for diagnostic yield of the 19-G EBUS-TBNA needle for suspected sarcoidosis. Eighty-six EBUS bronchoscopies were performed, 15 were done with clinical suspicion of sarcoidosis. The 19-G needle was used for all cases of suspected sarcoidosis. The procedure was diagnostic of sarcoidosis in 14 (93.3%) patients by TBNA with 1 nondiagnostic bronchoscopy. Procedural diagnostic yield was 93.3%. Eighty-five percent (28/33) of sampled lymph nodes were positive for noncaseating granulomas. The yield of transbronchial lung biopsy (TBLB) and endobronchial lung biopsy was 38% (5/13) and 43% (6/14), respectively. TBLB and endobronchial lung biopsy did not add to the diagnostic yield of the procedure. No significant adverse events were noted. This series reports a higher diagnostic yield than most other published studies and opens platform for direct comparison of each available needle. It also adds to the safety data for this larger needle. In addition, it raises doubt into utility of TBLB for diagnosis of sarcoidosis, which can increase the procedural complications.

  2. Treatment feasibility study of osteoporosis using minimal invasive laser needle system

    NASA Astrophysics Data System (ADS)

    Kang, Dongyeon; Ko, Chang-Yong; Ryu, Yeon-Hang; Park, Sunwook; Kim, Han-Sung; Jung, Byungjo

    2010-02-01

    Although the mechanism of laser stimulation effect in bone has not completely understood, laser stimulation is recommended in the treatment of osteoporosis due to positive treatment efficacy. In this study, a minimal invasive laser needle system (MILNS) was developed using a fine hollow needle in order to stimulate directly bone site by guiding an optical fiber. In order to evaluate the MILNS as a treatment method, in-vivo animal experiment study was performed using osteopenic mice. Twelve virginal ICR mice were employed and divided two groups: SHAM-group and LASERgroup. SHARM-group was stimulated by only fine hollow needle and LASER-group by fine hollow needle combined with laser stimulation. All mice were served in-vivo micro-CT images before and after treatment. Three dimensional (3D) structural parameters and vBMD (volume bone mineral density, g/cm3) in the trabecular bone were measured. After 2 weeks of stimulation, the vBMD, BV/TV, Tb.Th and Tb.N in LASER-group were significantly higher than those in SHAM-group (p<0.05). Potentially, this study suggested that the MILNS might prevent the bone loss and maintains the bone mineral density of osteopenic mice.

  3. Hashimoto thyroiditis: Part 1, sonographic analysis of the nodular form of Hashimoto thyroiditis.

    PubMed

    Anderson, Lauren; Middleton, William D; Teefey, Sharlene A; Reading, Carl C; Langer, Jill E; Desser, Terry; Szabunio, Margaret M; Hildebolt, Charles F; Mandel, Susan J; Cronan, John J

    2010-07-01

    The purpose of this article is to analyze the sonographic appearance of nodular Hashimoto thyroiditis. As part of an ongoing multiinstitutional study, patients who underwent ultrasound examination and fine-needle aspiration of one or more thyroid nodules were analyzed for multiple predetermined sonographic features. Patients completed a questionnaire, including information about thyroid function and thyroid medication. Patients (n = 61) with fine-needle aspiration cytologic results consistent with nodular Hashimoto thyroiditis (n = 64) were included in the study. The mean (+/- SD) diameter of nodular Hashimoto thyroiditis was 15 +/- 7.33 mm. Nodular Hashimoto thyroiditis occurred as a solitary nodule in 36% (23/64) of cases and in the setting of five or more nodules in 23% (15/64) of cases. Fifty-five percent (35/64) of the cases of nodular Hashimoto thyroiditis occurred within a sonographic background of diffuse Hashimoto thyroiditis, and 45% (29/64) of cases occurred within normal thyroid parenchyma. The sonographic appearance was extremely variable. It was most commonly solid (69% [42/61] of cases) and hypoechoic (47% [27/58] of cases). Twenty percent (13/64) of nodules had calcifications (seven with nonspecific bright reflectors, four with macrocalcifications, and three eggshell), and 5% (3/64) of nodules had colloid. Twenty-seven percent (17/64) of nodules had a hypoechoic halo. The margins were well defined in 60% (36/60) and ill defined in 40% (24/60) of nodules. On Doppler analysis, 35% (22/62) of nodules were hypervascular, 42% (26/62) were isovascular or hypovascular, and 23% (14/62) were avascular. The sonographic features and vascularity of nodular Hashimoto thyroiditis were extremely variable.

  4. Clinicopathological factors increased the risk of malignancy in thyroid nodules with atypical or follicular lesions of undetermined significance (AUS/FLUS) risk factor of malignancy in thyroid nodule with AUS/FLUS

    PubMed Central

    Hong, In Ki; Kim, Jun Ho; Cho, Young Up; Park, Shin-Young

    2016-01-01

    Purpose Ultrasound-guided fine needle aspiration (US-FNA) in thyroid nodules is presently most commonly used to identify whether these nodules are benign or malignant. However, atypical or follicular lesions of undetermined significance (AUS/FLUS), as categorized in the Bethesda System for reporting the results of FNA, cannot be classified as benign or malignant. Therefore, several clinical factors should be considered to assess the risk of malignancy in patients with AUS/FLUS. The purpose of the present study was to determine which clinical factor increased the risk of malignancy in patients with AUS/FLUS. Methods A retrospective study was done on 129 patients with fine needle aspiration categorized as AUS/FLUS from January 2011 through April 2015. Univariate and multivariate analyses were performed to assess the independent effect of risk factors such as age, sex, size of nodule, atypical descriptors, and ultrasonography criteria for malignancy. Results We identified that the presence of spiculated margin (odds ratio [OR], 5.655; 95% confidence interval [CI], 2.114-15.131; P = 0.001), nuclear grooving (OR, 3.697; 95% CI, 1.409-9.701; P = 0.008), irregular nuclei (OR, 3.903; 95% CI, 1.442-10.560; P = 0.001) were shown to be significantly related to malignancy on univariate and multivariate analyses. Conclusion We recommend that surgical resection of thyroid nodules be considered in patients with AUS/FLUS showing the histologic findings such as nuclear grooving, irregular nuclei along with spiculated margin of ultrasonographic finding. PMID:27073790

  5. Needle tip localization using stylet vibration.

    PubMed

    Harmat, Adam; Rohling, Robert N; Salcudean, Septimiu E

    2006-09-01

    Power Doppler ultrasound is used to localize the tip of a needle by detecting physical vibrations. Two types of vibrations are investigated, lateral and axial. The lateral vibrations are created by rotating a stylet, whose tip is slightly bent, inside a stationary cannula while the stylet is completely within the cannula. The minute deflection at the needle tip when rotated causes tissue motion. The axial vibration is induced by extending and retracting a straight stylet inside a stationary cannula. The stylet's tip makes contact with the tissue and causes it to move. The lateral vibration method was found to perform approximately the same under a variety of configurations (e.g., different insertion angles and depths) and better than the axial vibration method. Tissue stiffness affects the performance of the lateral vibration method, but good images can be obtained through proper tuning of the ultrasound machine.

  6. Calibration of 3D ultrasound to an electromagnetic tracking system

    NASA Astrophysics Data System (ADS)

    Lang, Andrew; Parthasarathy, Vijay; Jain, Ameet

    2011-03-01

    The use of electromagnetic (EM) tracking is an important guidance tool that can be used to aid procedures requiring accurate localization such as needle injections or catheter guidance. Using EM tracking, the information from different modalities can be easily combined using pre-procedural calibration information. These calibrations are performed individually, per modality, allowing different imaging systems to be mixed and matched according to the procedure at hand. In this work, a framework for the calibration of a 3D transesophageal echocardiography probe to EM tracking is developed. The complete calibration framework includes three required steps: data acquisition, needle segmentation, and calibration. Ultrasound (US) images of an EM tracked needle must be acquired with the position of the needles in each volume subsequently extracted by segmentation. The calibration transformation is determined through a registration between the segmented points and the recorded EM needle positions. Additionally, the speed of sound is compensated for since calibration is performed in water that has a different speed then is assumed by the US machine. A statistical validation framework has also been developed to provide further information related to the accuracy and consistency of the calibration. Further validation of the calibration showed an accuracy of 1.39 mm.

  7. Initiation and Characterization of Small Cell Lung Cancer Patient-Derived Xenografts from Ultrasound-Guided Transbronchial Needle Aspirates

    PubMed Central

    Anderson, Wade C.; Boyd, Michael B.; Aguilar, Jorge; Pickell, Brett; Laysang, Amy; Pysz, Marybeth A.; Bheddah, Sheila; Ramoth, Johanna; Slingerland, Brian C.; Dylla, Scott J.; Rubio, Edmundo R.

    2015-01-01

    Small cell lung cancer (SCLC) is a devastating disease with limited treatment options. Due to its early metastatic nature and rapid growth, surgical resection is rare. Standard of care treatment regimens remain largely unchanged since the 1980’s, and five-year survival lingers near 5%. Patient-derived xenograft (PDX) models have been established for other tumor types, amplifying material for research and serving as models for preclinical experimentation; however, limited availability of primary tissue has curtailed development of these models for SCLC. The objective of this study was to establish PDX models from commonly collected fine needle aspirate biopsies of primary SCLC tumors, and to assess their utility as research models of primary SCLC tumors. These transbronchial needle aspirates efficiently engrafted as xenografts, and tumor histomorphology was similar to primary tumors. Resulting tumors were further characterized by H&E and immunohistochemistry, cryopreserved, and used to propagate tumor-bearing mice for the evaluation of standard of care chemotherapy regimens, to assess their utility as models for tumors in SCLC patients. When treated with Cisplatin and Etoposide, tumor-bearing mice responded similarly to patients from whom the tumors originated. Here, we demonstrate that PDX tumor models can be efficiently established from primary SCLC transbronchial needle aspirates, even after overnight shipping, and that resulting xenograft tumors are similar to matched primary tumors in cancer patients by both histology and chemo-sensitivity. This method enables physicians at non-research institutions to collaboratively contribute to the rapid establishment of extensive PDX collections of SCLC, enabling experimentation with clinically relevant tissues and development of improved therapies for SCLC patients. PMID:25955027

  8. Ultrasound guided needle localization and microsurgical exploration for incidental nonpalpable testicular tumors.

    PubMed

    Hopps, Carin V; Goldstein, Marc

    2002-09-01

    We describe a technique by which incidental, nonpalpable intratesticular tumors are excised using intraoperative ultrasonography and the operating microscope. Men with impalpable intratesticular tumors incidentally detected by ultrasonography underwent intraoperative ultrasound guided needle localization and microsurgical exploration of the mass. The testis was delivered through an inguinal incision and placed on ice to minimize warm ischemia. Two rubber shod vascular clamps were placed across the spermatic cord. The tumor was identified by ultrasound and localized with a 30 gauge needle, which was placed adjacent to the tumor. An operating microscope providing 6x to 25x magnification was used to excise the lesion with a 2 to 5 mm. margin. Tissue diagnosis was obtained by frozen section. Multiple random biopsies of the remaining parenchyma were done to confirm absent malignancy. Ultrasound showed incidental, nonpalpable testis tumors in 4 of the 65 men who underwent infertility evaluation and were entered into the microsurgical testis biopsy database between January 1995 and December 2001. All lesions were hypoechoic. Frozen section analysis of the lesions revealed 2 Leydig cell tumors, 1 mass with an inconclusive pathological diagnosis and 1 inflammatory mass. On permanent section the latter 2 lesions were seminoma. The seminomas were 1.6 and 0.9 cm. in the greatest diameter, and the Leydig cell tumors were 0.35 and 0.2 cm., respectively. Random biopsies were positive for seminoma and intratubular germ cell neoplasia in both testes with seminoma. These 2 patients subsequently opted to undergo radical orchiectomy. No residual tumor was detected in either radical orchiectomy specimen. Intraoperative ultrasound guided needle localization with microsurgical exploration is a safe and effective approach to even small impalpable testicular masses. This technique provides the opportunity to identify and remove benign and malignant lesions, and preserve the testis when the lesion is benign. In cases of a solitary testis or bilateral synchronous lesions the technique allows a potentially testis sparing operation for small malignancies.

  9. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    PubMed

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  10. Diagnostic Criteria and Accuracy of Categorizing Malignant Thyroid Nodules by Ultrasonography and Ultrasound Elastography with Pathologic Correlation.

    PubMed

    Elsayed, Naglaa Mostafa; Elkhatib, Yasser Atta

    2016-03-01

    Thyroid nodules are a common medical and surgical concern. Thyroid ultrasound (US) is the primary imaging modality used for initial evaluation and assortment of nodules for fine needle aspiration (FNA) cytology/biopsy. Ultrasound elastography (USE) is believed to improve the diagnostic accuracy of US in distinguishing benign from malignant nodules. The aim of the work described here is to evaluate the diagnostic criteria and accuracy of US and USE in the diagnosis of malignant thyroid nodules. A prospective study of 88 patients who have thyroid nodules was performed. US, color Doppler, and USE were evaluated using a Philips iU22 equipped with a 5 to 12 MHz, linear transducer, followed by FNA of the each scanned nodule. The most sensitive US criteria for malignant nodules were a height-to-width ratio greater than one and the absence of a halo sign (sensitivity 0.875% and 1.000%, respectively). The most specific criteria for malignancy were a spiculated/blurred margin and the presence of microcalcifications (specificity 0.968% and 0.888%, respectively). The receiver operating characteristic curve showed that the cutoff diagnostic criteria of malignancy are two US characteristics and an elastography score of 4. The diagnostic accuracy of US for malignant thyroid nodules increases by combining US and USE. © The Author(s) 2015.

  11. Mistakes in ultrasound examination of salivary glands

    PubMed Central

    Jakubowski, Wiesław

    2016-01-01

    Ultrasonography is the first imaging method applied in the case of diseases of the salivary glands. The article discusses basic mistakes that can be made during an ultrasound examination of these structures. The reasons for these mistakes may be examiner-dependent or may be beyond their control. The latter may include, inter alia, difficult conditions during examination (technical or patient-related), similarity of ultrasound images in different diseases, the lack of clinical and laboratory data as well as the lack of results of other examinations, their insufficient number or incorrectness. Doctor-related mistakes include: the lack of knowledge of normal anatomy, characteristics of ultrasound images in various salivary gland diseases and statistical incidence of diseases, but also attaching excessive importance to such statistical data. The complex anatomical structures of the floor of the oral cavity may be mistaken for benign or malignant tumors. Fragments of correct anatomical structures (bones, arterial wall fibrosis, air bubbles in the mouth) can be wrongly interpreted as deposits in the salivary gland or in its excretory duct. Correct lymph nodes in the parotid glands may be treated as pathologic structures. Lesions not being a simple cyst, e.g. lymphoma, benign or malignant tumors of the salivary glands or metastatic lymph nodes, can be mistaken for one. The image of disseminated focal changes, both anechoic and solid, is not pathognomonic for specific diseases in the salivary glands. However, in part, it occurs typically and requires an extended differential diagnosis. Small focal changes and infiltrative lesions pose a diagnostic problem because their etiology cannot be safely suggested on the basis of an ultrasound examination itself. The safest approach is to refer patients with abnormal focal changes for an ultrasoundguided fine-needle aspiration biopsy. PMID:27446603

  12. Percutaneous CT-Guided Biopsy of the Lung: Comparison Between Aspiration and Automated Cutting Needles Using a Coaxial Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurent, Francois; Latrabe, Valerie; Vergier, Beatrice

    2000-07-15

    Purpose: To compare the accuracy and complication rate of two different CT-guided transthoracic needle biopsy techniques: fine needle aspiration and an automated biopsy device.Methods: Two consecutive series of respectively 125 (group A) and 98 (group B) biopsies performed using 20-22 gauge coaxial fine needle aspiration (group A) and an automated 19.5 gauge coaxial biopsy device (group B) were compared in terms of their accuracy and complication rate.Results: Groups A and B included respectively 100 (80%) and 77 (79%) malignant lesions and 25 (20%) and 18 (21%) benign lesions. No significant difference was found between the two series concerning patients, lesions,more » and procedural variables. For a diagnosis of malignancy, a statistically significant difference in sensitivity was found (82.7% vs 97.4%) between results obtained with the automated biopsy device and fine needle aspiration respectively. For a diagnosis of malignancy, the false negative rate of the biopsy result was significantly higher (p <0.005) in group A (17%) than in group B (2.6%). For a specific diagnosis of benignity, no statistically significant difference was found between the two groups (44% vs 26%) but the automated biopsy device provided fewer indeterminate cases. There was no difference between the two groups concerning the pneumothorax rate, which was 20% in group A and 15% in group B, or the hemoptysis rate, which was 2.4% in group A and 4% in group B.Conclusion: For a diagnosis of malignancy when a cytopathologist is not available on-site, automated biopsy devices provide a lower rate of false negative results and a similar complication rate to fine needle aspiration.« less

  13. Randomized comparison of three transducer orientation approaches for ultrasound guided internal jugular venous cannulation.

    PubMed

    Batllori, M; Urra, M; Uriarte, E; Romero, C; Pueyo, J; López-Olaondo, L; Cambra, K; Ibáñez, B

    2016-03-01

    Ultrasound-guided internal jugular venous access increases the rate of successful cannulation and reduces the incidence of complications, compared with the landmark technique. Three transducer orientation approaches have been proposed for this procedure: short-axis (SAX), long-axis (LAX) and oblique-axis (OAX). Our goal was to assess and compare the performance of these approaches. A prospective randomized clinical trial was conducted in one teaching hospital. Patients aged 18 yr or above, who were undergoing ultrasound-guided internal jugular cannulation, were randomly assigned to one of three intervention groups: SAX, LAX and OAX group. The main outcome measure was successful cannulation on first needle pass. Incidence of mechanical complications was also registered. Restricted randomization was computer-generated. In total, 220 patients were analysed (SAX n=73, LAX n=75, OAX n=72). Cannulation was successful on first needle pass in 51 (69.9%) SAX patients, 39 (52%) LAX patients and 53 (73.6%) OAX patients. First needle pass failure was higher in the LAX group than in the OAX group (adjusted OR 3.7, 95% CI 1.71-8.0, P=0.002). A higher mechanical complication rate was observed in the SAX group (15.1%) than in the OAX (6.9%) and LAX (4%) groups (P=0.047). As OAX showed a higher first needle pass success rate than LAX and a lower mechanical complications rate than SAX, we recommend it as the standard approach when performing ultrasound-guided internal jugular venous access. Further clinical studies are needed to confirm this conclusion. NCT 01966354. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    NASA Astrophysics Data System (ADS)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinen, R.; Tennet, P.

    Fine-grained sediments present in Florida Bay, the inner reef tract of Florida, and the Great Bahama Bank are formed by three processes. The sediments differ primarily in the amount of 4-{mu}m-long aragonite needles that comprise the sediment, but also in the amount of aragonite. Florida Bay muds are composed primarily of equant 1 {mu}m grains; less than 20% are needles. The fine-grained fraction from the inner reef tract of Florida contains more aragonite needles than Florida Bay muds. Some samples contain nearly 90% needles, whereas samples, from adjacent localities contain only 50%. Sediment from both areas is deposited and mixedmore » by bioturbation on the deltas at tidal passes through the Florida Keys. The amount of needle sediment diminishes rapidly away from the tidal passes in Florida Bay. The fine-grained fraction on the Great Bahama Bank is dominated by 4-{mu}m-long needles of aragonite but may contain fragments and whole tests of foraminifers. In general, the more abundant the aragonite-needle content is in any of the sediment, the greater the aragonite content of that sediment. The three main processes responsible for mud production on the Florida-Bahama Platform are (1) disintegration of skeletal encrustations, mainly red algae and spirobid worm tubules, on Thalassia grass blades; (2) postmortem disaggregation of aragonite needles from green algae; and (3) direct precipitation of aragonite and Mg-calcite from supersaturated marine waters. Where sufficient nutrients exist in the water column, such as in Florida Bay, mud production is dominated by the epibionts on the Thalassia grass community. Less nutrients in the water column of the inner reef tract results in fewer encrustations.« less

  16. Extraction and Chromatographic Determination of Shikimic Acid in Chinese Conifer Needles with 1-Benzyl-3-methylimidazolium Bromide Ionic Liquid Aqueous Solutions

    PubMed Central

    Chen, Fengli; Hou, Kexin; Li, Shuangyang; Zu, Yuangang; Yang, Lei

    2014-01-01

    An ionic liquids-based ultrasound-assisted extraction (ILUAE) method was successfully developed for extracting shikimic acid from conifer needles. Eleven 1-alkyl-3-methylimidazolium ionic liquids with different cations and anions were investigated and 1-benzyl-3-methylimidazolium bromide solution was selected as the solvent. The conditions for ILUAE, including the ionic liquid concentration, ultrasound power, ultrasound time, and liquid-solid ratio, were optimized. The proposed method had good recovery (99.37%–100.11%) and reproducibility (RSD, n = 6; 3.6%). ILUAE was an efficient, rapid, and simple sample preparation technique that showed high reproducibility. Based on the results, a number of plant species, namely, Picea koraiensis, Picea meyeri, Pinus elliottii, and Pinus banksiana, were identified as among the best resources of shikimic acid. PMID:24782942

  17. Utility of core biopsy with concurrent ROSE FNA in the diagnosis of pancreatic tumor-does the biopsy add any diagnostic benefit?

    PubMed

    Yan, Lei; Ikemura, Kenji; Park, Ji-Weon

    2018-02-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and endoscopic ultrasound-guided core-needle biopsy (EUS-CNB) are widely used for diagnosis of pancreatic tumors. The aim of our study was to compare the diagnostic performance of ROSE EUS-FNA and EUS-CNB for diagnosis of pancreatic malignancy during the same EUS. Patients who underwent both FNA and CNB during the same EUS for pancreatic solid lesion were reviewed retrospectively. Sample adequacy, diagnostic yield (defined as percentage of definitive diagnosis), sensitivity and specificity for malignancy were compared between FNA and CNB. A total of 48 patients with solid pancreatic lesions were evaluated. The proportions of adequate samples were 48/48 (100%) for FNA and 45/48 (93.7%) for core biopsy (P = .24). The diagnostic yield was 42/48 (87.5%) and 33/48 (68.7%) for FNA and CNB respectively (P = .046). The incremental increase in diagnostic yield by combining both methods was 2/48 (4%). The diagnostic yield for malignancy was 30/32 (93.7%) for FNA and 23/32 (71.8%) for CNB (P = .043). The sensitivity for the diagnosis of malignancy for FNA and CNB were 90.6% and 69%, respectively (P = .045). The specificity was 100% for both methods. The sensitivity for diagnosing malignancy increased to 93.8% when the two methods were combined. The difference in diagnostic yield was not associated with lesion size or location. EUS-guided FNA is a superior method of assessing solid pancreatic lesion and pancreatic malignancy with better diagnostic yield and higher sensitivity than EUS-CNB. © 2017 Wiley Periodicals, Inc.

  18. Diffuse sclerosing variant of thyroid carcinoma presenting as Hashimoto thyroiditis: a case report.

    PubMed

    Vukasović, Anamarija; Kuna, Sanja Kusacić; Ostović, Karmen Trutin; Prgomet, Drago; Banek, Tomislav

    2012-11-01

    The aim of report is to present a case of a rare diffuse sclerosing variant of a papillary thyroid carcinoma. A 15-year old girl referred for ultrasound examination because of painless thyroid swelling lasting 10 days before. An ultrasound of the neck showed diffusely changed thyroid parenchyma, without nodes, looking as lymphocytic thyroiditis Hashimoto at first, but with snow-storm appearance, predominantly in the right lobe. Positive thyroid peroxidase antibodies (TPO-AT) also suggested Hashimoto thyroiditis. Repeated US-FNAB (fine needle-aspiration biopsy) of the right lobe revealed diffuse sclerosing variant of papillary thyroid carcinoma and patient underwent total thyreoidectomy. Patohistologic finding confirmed diffuse sclerosing variant of a papillary thyroid carcinoma in the both thyroid lobes and several metastatic lymph nodes. Two months later patient recived radioablative therapy with 3700 MBq (100 mCi) of 1-131 followed by levothyroxine replacement. At the moment, patient is without evidence of local or distant metastases and next regular control is scheduled in 6 months. In conclusion, a diffuse sclerosing variant is rare form of papillary thyroid carcinoma that echographically looks similar to Hashimoto thyroiditis and sometimes could be easily overlooked.

  19. [Radiofrequency ablation as a palliative therapy option in ENT tumors: in vivo and in vitro testing].

    PubMed

    Bucher, S; Hornung, J; Bonkowsky, V; Iro, H; Zenk, J

    2010-04-01

    High frequency thermotherapy (HFTT) is an established palliative therapy for hepatic malignancies. An in vivo and in vitro trial examined the preconditions for the application of HFTT with liquid-cooled wet electrodes for minimally invasive palliation of head and neck tumors. HFTT was applied with needle electrodes, cooled with isotonic saline solution, and a high-frequency generator (Elektrotom HiTT 106, Berchtold, Tuttlingen) to porcine tongue and narcotized, juvenile domestic pigs to the tongue and neck, and monitored in realtime by B-mode ultrasound. The direction of spread of the hyperthermic zone is well observed using ultrasound. Determining the direction of spread is not possible with cooled-tip electrode needles. Severe complications were not observed during the application. RFA with liquid-cooled needle applicators is not safely applicable for the therapy of head and neck tumors.

  20. The protocol and preliminary baseline survey results of the thyroid ultrasound examination in Fukushima [Rapid Communication].

    PubMed

    Suzuki, Shinichi; Yamashita, Shunichi; Fukushima, Toshihiko; Nakano, Keiichi; Midorikawa, Sanae; Ohtsuru, Akira; Yasumura, Seiji; Hosoya, Mitsunori; Kamiya, Kenji; Shimura, Hiroki; Suzuki, Satoru; Nakamura, Izumi; Abe, Masafumi

    2016-01-01

    After the Fukushima nuclear power plant accident on March 11, 2011, the public of Japan became particularly concerned about the possibility of an increased risk of childhood thyroid cancer, similar to what was observed after the Chernobyl's accident. Due to serious public health perception, there was an urgency to evaluate the baseline levels of childhood thyroid status in Fukushima prefecture. Therefore we have commenced a thyroid ultrasound examination (TUE) survey of the approximately 360,000 pediatric inhabitants (0 to 18 years of age) who lived in Fukushima at the time of the accident in October 2011. The subjects were divided into three categories according to the standardized diagnostic criteria of ultrasound findings. Category A contained the subjects whose TUE findings were intact or benign. Category B were recommended a confirmatory TUE. Category C was recommended an immediate confirmatory TUE. The survey of 40,302 subjects in the first year was completed in March, 2013. There were 40,097 (99.5%), 205 (0.50%) and 0 subjects in categories A, B and C, respectively. Of the 82 category B subjects who underwent fine needle aspiration cytology (FNAC), 12 were diagnosed with a malignant tumor or were suspected to have malignancy. The 12 subjects received thyroid surgery and 11 thyroid cancers and one benign nodule were confirmed histologically after surgery. This is the first large-scaled TUE survey to employ sophisticated ultrasound screening and aim to evaluate the baseline frequency of childhood thyroid nodules and cysts. The results will become the golden standard of future comparative TUE in Fukushima, Japan.

  1. Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses

    PubMed Central

    Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao

    2018-01-01

    Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650

  2. Stunting of southern pine seedlings by a needle nematode (Longidorus sp.)

    Treesearch

    M.M. Cram; S.W. Fraedrich; J. Fields

    2003-01-01

    An undescribed needle nematode (Longidorus sp.) was consistently associated with stunted loblolly pine seedlings at the Flint River Nursery in south Georgia. Seedlings in affected areas had root systems that were greatly reduced in size, and lacked lateral and fine roots. In a growth chamber experiment, the needle nematode significantly reduced the...

  3. Electrodynamic Aerosol Concentrating and Sampling

    DTIC Science & Technology

    2006-06-16

    flat-plate AC electrode ...................................................................................................9 Figure 4. Corona needle ...Figure 4 shows a fine hypodermic needle used as a corona wire within the first quadrupole. The quadrupole electrodes would serve as the collecting...carefully expanded to better approximate hyperbolas. It is shown here with the inner needle corona electrode in place. Once it was determined that the

  4. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    PubMed

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  5. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    PubMed

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  6. Ultrasound-guided approach to the cervical articular process joints in horses: a validation of the technique in cadavers.

    PubMed

    Purefoy Johnson, Jessica; Stack, John David; Rowan, Conor; Handel, Ian; O'Leary, John Mark

    2017-05-22

    To compare accuracy of the ultrasound-guided craniodorsal (CrD) approach with the dorsal (D) approach to the cervical articular process joints, and to evaluate the effect of the transducer, needle gauge, and operator experience. Cervical articular process joints from 14 cadaveric neck specimens were injected using either a D or CrD approach, a linear (13 MHx) or microconvex transducer (10 MHz), and an 18 or 20 gauge needle, by an experienced or inexperienced operator. Injectate consisted of an iodinated contrast material solution. Time taken for injection, number of redirects, and retrieval of synovial fluid were recorded. Accuracy was assessed using a scoring system for contrast seen on computed tomography (CT). The successful performance of intra-articular injections of contrast detected by CT using the D (61/68) and CrD (57/64) approaches was comparable. No significant effect of approach, transducer or needle gauge was observed on injection accuracy, time taken to perform injection, or number of redirects. The 18 gauge needle had a positive correlation with retrieval of synovial fluid. A positive learning curve was observed for the inexperienced operator. Both approaches to the cervical articular process joints were highly accurate. Ultrasound-guided injection of the cervical articular process joints is an easily-learnt technique for an inexperienced veterinarian. Either approach may be employed in the field with a high level of accuracy, using widely available equipment.

  7. The comparative effectiveness of fine-needle aspiration cytology sampling policies: a simulation study.

    PubMed

    Schmidt, Robert L; Howard, Kirsten; Hall, Brian J; Layfield, Lester J

    2012-12-01

    Sample adequacy is an important aspect of overall fine-needle aspiration cytology (FNAC) performance. FNAC effectiveness is augmented by an increasing number of needle passes, but increased needle passes are associated with higher costs and greater risk of adverse events. The objective of this study was to compare the impact of several different sampling policies on FNAC effectiveness and adverse event rates using discrete event simulation. We compared 8 different sampling policies in 12 different sampling environments. All sampling policies were effective when the per-pass accuracy is high (>80%). Rapid on-site evaluation (ROSE) improves FNAC effectiveness when the per-pass adequacy rate is low. ROSE is unlikely to be cost-effective in sampling environments in which the per-pass adequacy is high. Alternative ROSE assessors (eg, cytotechnologists) may be a cost-effective alternative to pathologists when the per-pass adequacy rate is moderate (60%-80%) or when the number of needle passes is limited.

  8. Autonomous surgical robotics using 3-D ultrasound guidance: feasibility study.

    PubMed

    Whitman, John; Fronheiser, Matthew P; Ivancevich, Nikolas M; Smith, Stephen W

    2007-10-01

    The goal of this study was to test the feasibility of using a real-time 3D (RT3D) ultrasound scanner with a transthoracic matrix array transducer probe to guide an autonomous surgical robot. Employing a fiducial alignment mark on the transducer to orient the robot's frame of reference and using simple thresholding algorithms to segment the 3D images, we tested the accuracy of using the scanner to automatically direct a robot arm that touched two needle tips together within a water tank. RMS measurement error was 3.8% or 1.58 mm for an average path length of 41 mm. Using these same techniques, the autonomous robot also performed simulated needle biopsies of a cyst-like lesion in a tissue phantom. This feasibility study shows the potential for 3D ultrasound guidance of an autonomous surgical robot for simple interventional tasks, including lesion biopsy and foreign body removal.

  9. Ultrasound-guided interventional procedures around the shoulder.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria

    2016-01-01

    Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.

  10. An automated spring-loaded needle for endoscopic ultrasound-guided abdominal paracentesis in cancer patients

    PubMed Central

    Suzuki, Rei; Irisawa, Atsushi; Bhutani, Manoop S; Hikichi, Takuto; Takagi, Tadayuki; Shibukawa, Goro; Sato, Ai; Sato, Masaki; Ikeda, Tsunehiko; Watanabe, Ko; Nakamura, Jun; Annangi, Srinadh; Tasaki, Kazuhiro; Obara, Katsutoshi; Ohira, Hiromasa

    2014-01-01

    AIM: To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS: The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS: We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION: EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation. PMID:24567793

  11. Can a virtual reality assessment of fine motor skill predict successful central line insertion?

    PubMed

    Mohamadipanah, Hossein; Parthiban, Chembian; Nathwani, Jay; Rutherford, Drew; DiMarco, Shannon; Pugh, Carla

    2016-10-01

    Due to the increased use of peripherally inserted central catheter lines, central lines are not performed as frequently. The aim of this study is to evaluate whether a virtual reality (VR)-based assessment of fine motor skills can be used as a valid and objective assessment of central line skills. Surgical residents (N = 43) from 7 general surgery programs performed a subclavian central line in a simulated setting. Then, they participated in a force discrimination task in a VR environment. Hand movements from the subclavian central line simulation were tracked by electromagnetic sensors. Gross movements as monitored by the electromagnetic sensors were compared with the fine motor metrics calculated from the force discrimination tasks in the VR environment. Long periods of inactivity (idle time) during needle insertion and lack of smooth movements, as detected by the electromagnetic sensors, showed a significant correlation with poor force discrimination in the VR environment. Also, long periods of needle insertion time correlated to the poor performance in force discrimination in the VR environment. This study shows that force discrimination in a defined VR environment correlates to needle insertion time, idle time, and hand smoothness when performing subclavian central line placement. Fine motor force discrimination may serve as a valid and objective assessment of the skills required for successful needle insertion when placing central lines. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Rapid on-site assessment of specimens by biomedical scientists improves the quality of head and neck fine needle aspiration cytology.

    PubMed

    Breeze, J; Poller, D N; Gibson, D; Tilley, E A; Cooke, L; Soar, E; Repanos, C

    2014-10-01

    Immediate rapid on-site assessment (ROSA) of fine needle aspiration cytology (FNAC) specimens by biomedical scientists (BMS), the UK equivalent of cytotechnologists, or by pathologists may improve specimen quality and cellular adequacy rates for lymph node, head and neck and thyroid FNAC. The aim of this study was to evaluate the effect of introducing ROSA by BMS in an outpatient clinic setting. The adequacy rate and sensitivity of histological diagnosis for lymph node, thyroid and salivary gland FNAC samples were determined before and after the introduction of BMS ROSA. The additional financial costs and time required to perform this service were also estimated. Thirty-one patients underwent ultrasound (US)-guided FNAC with ROSA and 151 without. ROSA reduced the number of FNAC insufficient in quality for diagnosis from 43% to 19% (P = 0.0194). The estimated additional cost for pathology per patient for ROSA was between £52.05 and £70.74, equivalent to €65.40/US $83.90 and €88.89/US $114.0, respectively, an increase of between 28% and 49% from the original cost. ROSA necessitated an additional 6 minutes clinic time per patient, reducing the number of patients that could be seen in an average clinic from 13 to 10 as well as requiring increased laboratory time for FNAC slide assessment. ROSA by suitably trained biomedical scientists and with appropriate consultant pathologist support can improve the quality of FNAC sampling for head and neck lesions. Although ROSA resulted in both additional financial and time costs, these are more than likely to be offset by a reduction in patients returning to clinic for repeat FNAC or undergoing unnecessary surgery. © 2013 John Wiley & Sons Ltd.

  13. Hashimoto thyroiditis: Part 2, sonographic analysis of benign and malignant nodules in patients with diffuse Hashimoto thyroiditis.

    PubMed

    Anderson, Lauren; Middleton, William D; Teefey, Sharlene A; Reading, Carl C; Langer, Jill E; Desser, Terry; Szabunio, Margaret M; Mandel, Susan J; Hildebolt, Charles F; Cronan, John J

    2010-07-01

    The purpose of this article is to compare sonographic features of benign and malignant nodules in patients with diffuse Hashimoto thyroiditis. As part of an ongoing multiinstitutional study, patients who underwent ultrasound and fine-needle aspiration of one or more thyroid nodules were analyzed for a variety of predetermined sonographic features. Patients with a sonographic appearance consistent with diffuse Hashimoto thyroiditis and with coexisting nodules that could be confirmed to be benign or malignant by fine-needle aspiration or surgical pathologic analysis were included in the study. Among nodules within diffuse Hashimoto thyroiditis, 84% (69/82) were benign (35 nodular Hashimoto thyroiditis, 32 nodular hyperplasia, and two follicular adenoma), and 16% (13/82) were malignant (12 papillary carcinoma and one lymphoma). Malignant nodules were more likely to be solid and hypoechoic (62% vs 19%). All types of calcifications were more prevalent among malignant nodules, including microcalcifications (39% vs 0%), nonspecific tiny bright reflectors (39% vs 6%), macrocalcifications (15% vs 3%), and eggshell (15% vs 2%). Benign nodules were more likely to be hyperechoic (46% vs 9%), to have a halo (39% vs 15%), and to lack calcifications (88% vs 23%). Benign nodules more often had ill-defined margins (36% vs 8%). Sonographic features of benign and malignant nodules within diffuse Hashimoto thyroiditis are generally similar to the features typical of benign and malignant nodules in the general population. If calcifications of any type are added to the list of malignant sonographic features, the decision to biopsy a nodule in patients with diffuse Hashimoto thyroiditis can be based on recommendations that have been published previously.

  14. Metastatic tonsillar squamous cell carcinoma masquerading as a pancreatic cystic tumor and diagnosed by EUS-guided FNA.

    PubMed

    Glass, Ryan; Andrawes, Sherif A; Hamele-Bena, Diane; Tong, Guo-Xia

    2017-11-01

    Metastatic carcinoma to the pancreas is uncommon and head and neck squamous carcinoma metastatic to the pancreas is extremely rare. Metastatic squamous cell carcinoma to the pancreas presents a unique diagnostic challenge: in addition to mimicking the rare primary squamous cell carcinoma of the pancreas based on cytologic, histologic, and immunohistochemical features, it may be mistaken for a cystic neoplasm of the pancreas because of its high predilection for cystic degeneration in metastatic sites. Herein, we report a case of tonsillar squamous cell carcinoma with a cystic pancreatic metastasis diagnosed by ultrasound-guided fine needle aspiration biopsy (EUS-FNA). This represents a third reported case of metastatic squamous cell carcinoma to the pancreas from the head and neck region. Metastatic squamous cell carcinoma should be considered in the differential diagnosis of EUS-FNA during evaluation of pancreatic cystic lesion. © 2017 Wiley Periodicals, Inc.

  15. A primary cavernous hemangioma of the thyroid gland: A case report and literature review.

    PubMed

    Miao, Jie; Chen, Shubo; Li, Yongcai; Fu, Lin; Li, Hui

    2017-12-01

    Thyroid hemangioma is benign and associated with fine-needle aspiration (FNA) biopsy or trauma in most cases. Its differential diagnosis is very difficult. We presented the case of a 48-year-old man complained of slowly progressed swelling in the anterior neck for 20 years. Ultrasound and CT scan revealed a hypoechogenic and heterogeneous mass measuring 4 × 3.5 cm located in the right lobe of thyroid gland. Postoperative pathological and immunohistochemical examinations of the surgical specimen revealed a primary hemangioma of the thyroid gland. The patient received a right lobectomy of the thyroid. The patient had been followed up for 10 months after surgery without complications and remained asymptomatic. Primary thyroid hemangioma should be considered when there is a well-circumscribed capsule mass on medical imaging without history of FNA or any other cervical procedures or trauma.

  16. Primary esophageal mucosa-associated lymphoid tissue lymphoma diagnosed by using stacked forceps biopsy.

    PubMed

    Lee, D S; Ahn, Y C; Eom, D W; Lee, S J

    2016-10-01

    Non-Hodgkin lymphoma involving the esophagus is very rare. Only a few cases have been reported in the English literature to date, and it accounts for less than 1% of all cases of gastrointestinal lymphoma. As this malignancy manifests as a submucosal tumor, pathological diagnosis by using a simple endoscopic biopsy alone is difficult. Therefore, surgical biopsy, endoscopic mucosal resection, and endoscopic ultrasound-guided fine-needle aspiration have been used in most cases. Herein, we report a case of esophageal mucosa-associated lymphoid tissue lymphoma in a 49-year-old man, which involved the use of a stacked forceps biopsy to obtain adequate samples for pathological analysis; the use of the stacked forceps biopsy method is unlike those used in previous cases. The patient received cyclophosphamide, vincristine, and prednisolone chemotherapy; he achieved a complete response. In addition, we review the literature relevant to this case. © 2015 International Society for Diseases of the Esophagus.

  17. Management of Orbital Diseases.

    PubMed

    Betbeze, Caroline

    2015-09-01

    Orbital diseases are common in dogs and cats and can present on emergency due to the acute onset of many of these issues. The difficulty with diagnosis and therapy of orbital disease is that the location of the problem is not readily visible. The focus of this article is on recognizing classical clinical presentations of orbital disease, which are typically exophthalmos, strabismus, enophthalmos, proptosis, or intraconal swelling. After the orbital disease is confirmed, certain characteristics such as pain on opening the mouth, acute vs. chronic swelling, and involvement of nearby structures can be helpful in determining the underlying cause. Abscesses, cellulitis, sialoceles, neoplasia (primary or secondary), foreign bodies, and immune-mediated diseases can all lead to exophthalmos, but it can be difficult to determine the cause of disease without advanced diagnostic imaging, such as ultrasound, magnetic resonance imaging, or computed tomography scan. Fine-needle aspirates and biopsies of the retrobulbar space can also be performed. Published by Elsevier Inc.

  18. A double conundrum: concurrent presentation of Hashimoto's thyroiditis and ulcerative colitis

    PubMed Central

    Singh, Gurpreet; Brien, Susie; Taylor, Ellen

    2016-01-01

    We describe a case of a 31-year-old man who presented with a 3-day history of crampy abdominal pain, anorexia, malaise and diarrhoea of increasing frequency, with the passage of both mucus and haematochezia. The patient's biochemical investigations revealed hyponatraemia, hypothyroidism and elevated inflammatory markers. The patient underwent an ultrasound and fine-needle aspiration of the thyroid and was diagnosed as having Hashimoto's thyroiditis. He was started on thyroxine and fluid was restricted. He was also investigated for alternative causes of hyponatraemia. With improvement in his hyponatraemia, the patient underwent a colonoscopy with biopsies confirming a concurrent diagnosis of ulcerative colitis. He was started on mesalazine and prednisolone and discharged from hospital. He suffered a flare shortly after discharge and was readmitted to hospital. He was again discharged, on a higher dose of prednisolone, with outpatient follow-up at our hospital's gastroenterology clinic. PMID:27107058

  19. Non-infected and Infected Bronchogenic Cyst: The Correlation of Image Findings with Cyst Content

    PubMed Central

    Jeon, Hong Gil; Park, Ju Hwan; Park, Hye Min; Kwon, Woon Jung; Cha, Hee Jeong; Lee, Young Jik; Park, Chang Ryul; Jegal, Yangjin; Ahn, Jong-Joon

    2014-01-01

    We hereby report a case on bronchogenic cyst which is initially non-infected, then becomes infected after bronchoscopic ultrasound (US)-guided transesophageal fine-needle aspiration (FNA). The non-infected bronchogenic cyst appears to be filled with relatively echogenic materials on US, and the aspirate is a whitish jelly-like fluid. Upon contrast-enhanced MRI of the infected bronchogenic cyst, a T1-weighted image shows low signal intensity and a T2-weighted image shows high signal intensity, with no enhancements of the cyst contents, but enhancements of the thickened cystic wall. The patient then undergo video-assisted thoracic surgery 14 days after the FNA. The cystic mass is known to be completely removed, and the aspirate is yellowish and purulent. To understand the image findings that pertain to the gross appearance of the cyst contents will help to diagnose bronchogenic cysts in the future. PMID:24624219

  20. Techniques for cytologic sampling of pancreatic and bile duct lesions.

    PubMed

    Brugge, William; Dewitt, John; Klapman, Jason B; Ashfaq, Raheela; Shidham, Vinod; Chhieng, David; Kwon, Richard; Baloch, Zubair; Zarka, Matthew; Staerkel, Gregg

    2014-04-01

    The Papanicolaou Society of Cytopathology has developed a set of guidelines for pancreatobiliary cytology including indications for endoscopic ultrasound guided fine-needle aspiration biopsy, techniques of the endoscopic retrograde cholangiopancreatography, terminology and nomenclature of pancreatobiliary disease, ancillary testing, and postbiopsy management. All documents are based on the expertise of the authors, a review of the literature, discussions of the draft document at several national and international meetings over an 18-month period and synthesis of online comments of the draft document on the Papanicolaou Society of Cytopathology website [www.papsociety.org]. This document presents the results of these discussions regarding the use of ancillary testing in the cytological diagnosis of biliary and pancreatic lesions. This document summarizes the current state of the art for techniques in acquiring cytology specimens from the biliary tree as well as solid and cystic lesions of the pancreas. Copyright © 2014 Wiley Periodicals, Inc.

  1. Techniques for cytologic sampling of pancreatic and bile duct lesions: The Papanicolaou Society of Cytopathology Guidelines.

    PubMed

    Brugge, William R; De Witt, John; Klapman, Jason B; Ashfaq, Raheela; Shidham, Vinod; Chhieng, David; Kwon, Richard; Baloch, Zubair; Zarka, Matthew; Staerkel, Gregg

    2014-01-01

    The Papanicolaou Society of Cytopathology has developed a set of guidelines for pancreatobiliary cytology, including indications for endoscopic ultrasound guided fine-needle aspiration biopsy, techniques of the endoscopic retrograde cholangiopancreatography, terminology and nomenclature of pancreatobiliary disease, ancillary testing, and postbiopsy management. All documents are based on the expertise of the authors, a review of literature, discussions of the draft document at several national and international meetings over an 18 month period and synthesis of online comments of the draft document on the Papanicolaou Society of Cytopathology website [www.papsociety.org]. This document presents the results of these discussions regarding the use of sampling techniques in the cytological diagnosis of biliary and pancreatic lesions. This document summarizes the current state of the art for techniques in acquiring cytology specimens from the biliary tree as well as solid and cystic lesions of the pancreas.

  2. Breast metastases from colorectal carcinoma.

    PubMed

    Mihai, Radu; Christie-Brown, Jonathan; Bristol, James

    2004-04-01

    A case history is presented of a 53-year-old woman with an incidental finding of a breast lump, identified after having had chemotherapy for lung metastases from a rectal carcinoma. Clinical examination, ultrasound, mammography, fine needle aspiration and core biopsies could not prove definitively whether the breast lump represented a metastasis from colorectal carcinoma. Following local excision, the final diagnosis of metastatic colorectal carcinoma to the breast was based on the absence of any site of origin within the breast (i.e. no surrounding DCIS) and on the expression of cytokeratin CK7 and CK20 on immunohistochemistry. Postoperative chemotherapy was initiated. Four months later, although without local recurrence in the breast, the patient developed cutaneous metastatic deposits and active treatment was stopped. A review of other cases of breast metastases from extramammary sources is presented. Possible mechanisms for this rare and unusual phenomenon are discussed.

  3. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    PubMed

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  4. Prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy: A prospective multicenter study.

    PubMed

    Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon

    2018-03-01

    To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.

  5. The intraoperative use of ultrasound facilitates significantly the arthroscopic debridement of calcific rotator cuff tendinitis.

    PubMed

    Sabeti, M; Schmidt, M; Ziai, P; Graf, A; Nemecek, E; Schueller-Weidekamm, C

    2014-05-01

    During arthroscopy, the localization of calcific deposit in patients suffering from calcifying tendinitis can be demanding and time consuming, frequently using ionizing radiation. Intraoperative ultrasound has been recently promoted, facilitating deposit localization and reducing radiation dose. In this prospective, randomized, controlled and clinical observer-blinded pilot trial, 20 patients with calcific tendinitis were operated. In group I, the deposit was localized conventionally. In group II, the deposit was localized using intraoperative ultrasound. The needle punctures to detect the deposit and operation times were noted. Patients were postoperatively evaluated after 2 and 6 weeks and 9 months. In group II, the needle punctures to detect the deposit were significantly lower than in group I (p < 0.0001). Operation time to localize the deposit was also significantly less in group II (p < 0.033). In both groups, patients improved significantly with increased shoulder function (p < 0.0001) and decreased pain (p < 0.0001) 2 weeks and 9 months (p < 0.001) after surgery. The difference between the groups was not significant. Excellent radiological findings were obtained in both groups after 9 months. Intraoperative US significantly facilitates the detection of calcific deposits during arthroscopic debridement by speeding up surgery and reducing the number of needle punctures. Hence, we have changed our method of detecting calcific deposits intraoperatively from fluoroscopy to ultrasound.

  6. Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.

    PubMed

    Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman

    2013-10-01

    Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.

  7. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    PubMed

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    PubMed

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions < 10 mm (7.2%) (P < .01) but without statistically significant differences among the 3 gauges (P > .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Successful treatment of athletic pubalgia in a lacrosse player with ultrasound-guided needle tenotomy and platelet-rich plasma injection: a case report.

    PubMed

    Scholten, Paul M; Massimi, Stephen; Dahmen, Nick; Diamond, Joanne; Wyss, James

    2015-01-01

    Athletic pubalgia is a syndrome of persistent groin pain due to chronic repetitive trauma or stress involving the pelvic joints and many musculotendinous structures that cross the anterior pelvis. As a result, the differential diagnosis can be complex, but insertional tendinopathies are the most common. This case report describes a novel approach to the treatment of distal rectus abdominis tendinopathies with ultrasound-guided needle tenotomy and platelet-rich plasma (PRP) injection. After injection, the patient returned to pain-free play at his previous level of intensity. This suggests that PRP may be a useful treatment for this diagnosis. Copyright © 2015. Published by Elsevier Inc.

  10. A rare constellation of empyema, lung abscess, and mediastinal abscess as a complication of endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen

    2011-07-01

    The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  11. Endobronchial ultrasound-guided lymph node biopsy with transbronchial needle forceps: a pilot study.

    PubMed

    Herth, F J F; Schuler, H; Gompelmann, D; Kahn, N; Gasparini, S; Ernst, A; Schuhmann, M; Eberhardt, R

    2012-02-01

    One limitation of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the size of the available needles, frequently yielding only cells for cytological examination. The aim of this pilot study was to evaluate the efficacy and safety of newly developed needle forceps to obtain tissue for the histological diagnosis of enlarged mediastinal lymph nodes. Patients with enlarged, positron emission tomography (PET)-positive lymph nodes were included. The transbronchial needle forceps (TBNF), a sampling instrument combining the characteristics of a needle (bevelled tip for penetrating through the bronchial wall) with forceps (two serrated jaws for grasping tissue) was used through the working channel of the EBUS-TBNA scope. Efficacy and safety was assessed. 50 patients (36 males and 14 females; mean age 51 yrs) with enlarged or PET-positive lymph nodes were included in this pilot study. In 48 (96%) patients penetration of the bronchial wall was possible and in 45 patients tissue for histological diagnosis was obtained. In three patients TBNF provided inadequate material. For patients in whom the material was adequate for a histological examination, a specific diagnosis was established in 43 (86%) out of 50 patients (nonsmall cell lung cancer: n=24; small cell lung cancer: n=7; sarcoidosis: n=4; Hodgkin's lymphoma: n=4; tuberculosis: n=2; and non-Hodgkin's lymphoma: n=2).No clinically significant procedure-related complications were encountered. This study demonstrated that EBUS-TBNF is a safe procedure and provides diagnostic histological specimens of mediastinal lymph nodes.

  12. Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer.

    PubMed

    Huang, Chih-Chung; Chen, Ruimin; Tsui, Po-Hsiang; Zhou, Qifa; Humayun, Mark S; Shung, K Kirk

    2009-10-07

    A cataract is a clouding of the lens in the eye that affects vision. Phacoemulsification is the mostly common surgical method for treating cataracts, and determining that the optimal phacoemulsification energy is dependent on measuring the hardness of the lens. This study explored the use of an ultrasound needle transducer for invasive measurements of ultrasound attenuation coefficient to evaluate the hardness of the cataract lens. A 47 MHz high-frequency needle transducer with a diameter of 0.9 mm was fabricated by a polarized PMN-33%PT single crystal in the present study. The attenuation coefficients at different stages of an artificial porcine cataract lens were measured using the spectral shift approach. The hardness of the cataract lens was also evaluated by mechanical measurement of its elastic properties. The results demonstrated that the ultrasonic attenuation coefficient was increased from 0.048 +/- 0.02 to 0.520 +/- 0.06 dB mm(-1) MHz(-1) corresponding to an increase in Young's modulus from 6 +/- 0.4 to 96 +/- 6.2 kPa as the cataract further developed. In order to evaluate the feasibility of combining needle transducer and phacoemulsification probe for real-time measurement during cataract surgery, the needle transducer was mounted on the phacoemulsification probe for a vibration test. The results indicated that there was no apparent damage to the tip of the needle transducer and the pulse-echo test showed that a good performance in sensitivity was maintained after the vibration test.

  13. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    PubMed

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  14. Conventional Landmark-Guided Midline Versus Preprocedure Ultrasound-Guided Paramedian Techniques in Spinal Anesthesia.

    PubMed

    Kallidaikurichi Srinivasan, Karthikeyan; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2015-10-01

    Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of postdural puncture headache, paraesthesia, and spinal hematoma. We hypothesized that the routine use of a preprocedural ultrasound-guided paramedian technique for spinal anesthesia would reduce the number of passes required to achieve entry into the subarachnoid space when compared with the conventional landmark-guided midline approach. One hundred consenting patients scheduled for elective total joint replacements (hip and knee) were randomized into group C (conventional) and group P (preprocedural ultrasound-guided paramedian technique) with 50 in each group. The patients were blinded to the study group. All spinal anesthetics were administered by a consultant anesthesiologist. In group C, spinal anesthetic was done via the midline approach using clinically palpated landmarks. In group P, a preprocedural ultrasound scan was used to mark the paramedian insertion site, and spinal anesthetic was performed via the paramedian approach. The average number of passes (defined as the number of forward advancements of the spinal needle in a given interspinous space, i.e., withdrawal and redirection of spinal needle without exiting the skin) in group P was approximately 0.34 times that in group C, a difference that was statistically significant (P = 0.01). Similarly, the average number of attempts (defined as the number of times the spinal needle was withdrawn from the skin and reinserted) in group P was approximately 0.25 times that of group C (P = 0.0021). In group P, on an average, it took 81.5 (99% confidence interval, 68.4-97 seconds) seconds longer to identify the landmarks than in group C (P = 0.0002). All other parameters, including grading of palpated landmarks, time taken for spinal anesthetic injection, periprocedural pain scores, periprocedural patient discomfort visual analog scale score, conversion to general anesthetic, paresthesia, and radicular pain during needle insertion, were similar between the 2 groups. Routine use of paramedian spinal anesthesia in the orthopedic patient population undergoing joint replacement surgery, guided by preprocedure ultrasound examination, significantly decreases the number of passes and attempts needed to enter the subarachnoid space.

  15. Incidence of breast cancer in patients with pure flat epithelial atypia diagnosed at core-needle biopsy of the breast.

    PubMed

    Khoumais, Nuha A; Scaranelo, Anabel M; Moshonov, Hadas; Kulkarni, Supriya R; Miller, Naomi; McCready, David R; Youngson, Bruce J; Crystal, Pavel; Done, Susan J

    2013-01-01

    to determine the frequency of malignancy in subsequent breast excisions following core-needle biopsy (CNB) diagnosis of pure flat epithelial atypia (pFEA) and to evaluate the imaging features of the associated tumors. Retrospective review of 8,996 image-guided CNB (2002-2010) identified 115 cases of FEA not associated with other atypia. Patients with history of breast cancer or radiation therapy were excluded. One hundred four cases (women) with pFEA (mean age 51 years, range 29-77 years) were reviewed. Stereotactic CNB was performed in 79 (76%) cases and ultrasound (US)-guided CNB in 25 (24%) cases. In 99 cases 14G needles were used, and 10G vacuum-assisted devices were used in 5 cases. Ninety-four patients had subsequent excision. Ten patients declined excision, and imaging follow-up (mean of 36 months) is available. The upgrade rate of pFEA was defined as the number of patients diagnosed with invasive carcinoma (IC) or carcinoma in situ (CIS) divided by the total number of patients. 10 of 104 (9.6%) patients were diagnosed with cancer: 9 presented as calcifications (89% fine pleomorphic and amorphous) and 1 case as a mammographically occult mass. The size of calcifications was not statistically significant (P=0.358). Five cases had ductal carcinoma in situ (DCIS) and five cases had IC (ductal and lobular) presenting as amorphous and pleomorphic calcifications. The upgrade rate of pFEA in our series was 9.6%. The presence of 4.8% of invasive cancers is substantial and warrants continuing management with surgical excision in all cases.

  16. Giant juvenile fibroadenoma: a systematic review with diagnostic and treatment recommendations

    PubMed Central

    Pulcrano, Marisa; Feldman, Elizabeth D.; Patel, Ketan M.; Nahabedian, Maurice Y.; Weissler, Jason M.; Rodriguez, Eduardo D.

    2015-01-01

    Background Currently, there is a lack of clear guidelines regarding evaluation and management of giant juvenile fibroadenomas. The purpose of this study was to conduct a systematic review of giant juvenile fibroadenomas and to evaluate the most common diagnostic and therapeutic modalities. Methods A systematic literature search of PubMed and MEDLINE databases was conducted in February 2014 to identify articles related to giant juvenile fibroadenomas. Pooled outcomes are reported. Results Fifty-two articles (153 patients) met inclusion criteria. Mean age was 16.7 years old, with a mean lesion size of 11.2 cm. Most patients (86%) presented with a single breast mass. Imaging modalities included ultrasound in 72.5% and mammography in 26.1% of cases. Tissue diagnosis was obtained using a core needle biopsy in 18.3% of cases, fine-needle aspiration (FNA) in 25.5%, and excisional biopsy in 11.1% of patients. Surgical treatment was implemented in 98.7% of patients (mean time to treatment of 9.5 months, range, 3 days to 7 years). Surgical intervention included excision in all cases, of which four were mastectomies. Breast reconstruction was completed in 17.6% of cases. There were no postoperative complications. Conclusions Diagnosis and treatment of giant juvenile fibroadenoma is heterogeneous. There is a paucity of data to support observation and non-operative treatment. The most common diagnostic modalities include core needle or excisional biopsy. The mainstay of treatment is complete excision with an emphasis on preserving the developing breast parenchyma and nipple areolar complex. Breast reconstruction is uncommon, but may be necessary in certain cases. PMID:26312217

  17. The integration of single fiber reflectance (SFR) spectroscopy during endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) in pancreatic masses: a feasibility study

    NASA Astrophysics Data System (ADS)

    Stegehuis, Paulien L.; Boogerd, Leonora S. F.; Inderson, Akin; Veenendaal, Roeland A.; Bonsing, Bert A.; Amelink, Arjen; Vahrmeijer, Alexander L.; Dijkstra, Jouke; Robinson, Dominic J.

    2016-03-01

    EUS-FNA can be used for pathological confirmation of a suspicious pancreatic mass. However, performance depends on an on-site cytologist and time between punction and final pathology results can be long. SFR spectroscopy is capable of extracting biologically relevant parameters (e.g. oxygenation and blood volume) in real-time from a very small tissue volume at difficult locations. In this study we determined feasibility of the integration of SFR spectroscopy during EUSFNA procedures in pancreatic masses. Patients with benign and malignant pancreatic masses who were scheduled for an EUS-FNA were included. The working guide wire inside the 19 gauge endoscopic biopsy needle was removed and the sterile single fiber (300 μm core and 700 μm outer diameter, wide-angle beam, NA 0.22) inserted through the needle. Spectroscopy measurements in the visiblenear infrared wavelength region (400-900 nm) and autofluorescence measurements (excitation at 405 nm) were taken three times, and subsequently cytology was obtained. Wavelength dependent optical properties were compared to cytology results. We took measurements in 13 patients with corresponding cytology results (including mucinous tumor, ductal adenocarcinoma, neuroendocrine tumor, and pancreatitis). In this paper we show the first analyzed results comparing normal pancreatic tissue with cancerous tissue in the same patient. We found a large difference in blood volume fraction, and blood oxygenation was higher in normal tissue. Integration of SFR spectroscopy is feasible in EUS-FNA procedures, the workflow hardly requires changes and it takes little time. The first results differentiating normal from tumor tissue are promising.

  18. Thyroid nodules in the population living around Semipalatinsk nuclear test site: possible implications for dose-response relationships study.

    PubMed

    Zhumadilov, Zhaxybay

    2006-02-01

    The risk of radiation-induced nodules is higher than the risk for radiation-induced cancer. Risk factors and specific modifiers of the dose-response relationship may vary among different populations and not be well recognized. Many thyroid studies have considered thyroid nodularity itself, but not specific morphological types of thyroid nodules. There are many specific types of thyroid nodules which follow a morphological classification of thyroid lesions, including some congenital and tumor-like conditions. Modern equipment and technique can help us to identify particular specific types of thyroid nodules. In this study we report some results of a clinically applicable approach to materials derived from three studies. From 1999 through 2002, we have screened 571 current residents from 4 exposed and 1 control village near the Semipalatinsk Nuclear Test Site area, who were of similar ages (<20) at the time of major radiation fallout events at the SNTS. Prevalent nodules were identified by ultrasound and fine-needle aspiration biopsy, cytopathology results. Analysis of ultrasound images and cytopathology of thyroid lesions among exposed and non-exposed population allowed us to distinguish some interesting ultrasound features for specific types of thyroid nodules. We believe that it would be interesting and possibly more informative for thyroid dosimetry studies to consider specific morphological types of thyroid nodules. We need more detailed research to clarify the feasibility of applying these findings for study of the dose-response relationship.

  19. Endoscopic Ultrasound Imaging for Differential Diagnosis of Pancreatic Neoplasms: A 7-Year Study in a Chinese Population.

    PubMed

    Cui, Binxin; Fang, Weili; Khan, Samiullah; Li, Shu; Chang, Yixiang; Wang, Bangmao; Liu, Wentian

    2018-06-01

    BACKGROUND Currently, non-invasive methods for screening pancreatic cancer are lacking. There is little information regarding whether endoscopic ultrasound (EUS) imaging has a discriminatory ability for detecting benign and malignant pancreatic neoplasms. In this study, we retrospectively analyzed the demographic, clinicopathologic, and EUS features and follow-up information. MATERIAL AND METHODS A total of 58 patients with pancreatic neoplasms who underwent endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) over a 7-year period (2009-2016) at our Department of Digestive Diseases were enrolled in our study. RESULTS Of the 58 patients, 38 (65.5%) were diagnosed with malignant pancreatic neoplasms and 20 (34.5%) were benign ones. Of all the EUS findings, size of neoplasm (P=0.037) and regularity of margin (P=0.011) were significantly different between malignant and benign pancreatic neoplasms. However, age, sex, location, echo pattern, and dilation of main pancreatic duct did not show any significant difference (P>0.05). Size combined with regularity to detect malignant pancreatic neoplasms showed the following diagnostic values: sensitivity, 73.68%; specificity, 90%; positive predictive value, 76.60%; negative predictive value 81.82%; and area under the receiver operating characteristic curve, 0.887 (95% CI: 0.777-0.955, P<0.0001). CONCLUSIONS Our results showed the high value of EUS for differentiating malignant pancreatic neoplasms from benign ones. Due to this and its non-invasive nature, EUS should be the first-line method for detection of neoplastic pancreatic lesions.

  20. Carcinoma in ectopic breast: a cytological diagnosis.

    PubMed

    Shukla, Shailaja; Sehgal, Shivali; Rai, Preeti; Agarwal, Kiran

    2015-01-01

    Ectopic breast carcinoma in the axillary region is rare with an incidence ranging from 0.3-6%. We report a case of infiltrating duct carcinoma in an adult female arising in aberrant breast tissue in the axilla diagnosed on fine needle aspiration cytology. There was history of recent increase in size of the lump which was otherwise present for the past 5 years. This case highlights the role fine needle aspiration cytology can play in the early diagnosis of malignant transformation of lumps.

  1. Aspergillus thyroiditis: first antemortem case diagnosed by fine-needle aspiration culture in a pediatric stem cell transplant patient.

    PubMed

    Badawy, S M; Becktell, K D; Muller, W J; Schneiderman, J

    2015-12-01

    Aspergillus thyroiditis (AT) has historically been considered a postmortem diagnosis in immunocompromised patients; most have disseminated disease. This report summarizes the clinical challenge of diagnosing AT. It also highlights the value of the early use of thyroid fine-needle aspiration culture and the need for a high index of suspicion to reach the final diagnosis before disease dissemination. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Fine needle aspiration cytology in the management of head and neck masses.

    PubMed

    Slack, R W; Croft, C B; Crome, L P

    1985-04-01

    Fine needle aspiration cytology is a useful technique in the management of patients with masses in the head and neck, which is usually performed in co-operation with a specialized cytopathologist. It has not until recently been an investigation used frequently by British otolaryngologists. This study shows that an aspiration cytology service may be run with the aid of a general histopathologist and demonstrates that it is a valuable aid to diagnosis even without the services of a specialized cytopathologist.

  3. Broadsheet number 57: problems in fine needle biopsy of the thyroid.

    PubMed

    Orell, S R; Philips, J

    2000-08-01

    The role of fine needle biopsy and cytological diagnosis in the preoperative evaluation of thyroid nodules is reviewed on the basis of the current literature as well as the authors' personal experience. Technical aspects and guidelines for reporting thyroid samples are discussed in some detail. The main emphasis is on diagnostic pitfalls, those which may lead to a false-negative diagnosis, to a false-positive diagnosis or to an erroneous typing of the lesion, and their cytological patterns are described.

  4. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil*,**

    PubMed Central

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients. PMID:25750671

  5. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil.

    PubMed

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.

  6. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    PubMed

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart. Use of the novel SonixGPS needle-tracking ultrasound system (UltraSonix, Richmond, BC, Canada) was not associated with a higher success rate of vascular puncture compared with the traditional ultrasound-guided technique. Assessment of mental task load significantly favored the use of the ultrasound GPS over the traditional ultrasound technique. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  7. Thyroid Nodule Size at Ultrasound as a Predictor of Malignancy and Final Pathologic Size.

    PubMed

    Cavallo, Allison; Johnson, Daniel N; White, Michael G; Siddiqui, Saaduddin; Antic, Tatjana; Mathew, Melvy; Grogan, Raymon H; Angelos, Peter; Kaplan, Edwin L; Cipriani, Nicole A

    2017-05-01

    Thyroid-related mortality has remained constant despite the increasing incidence of thyroid carcinoma. Most thyroid nodules are benign; therefore, ultrasound and fine needle aspiration (FNA) are integral in cancer screening. We hypothesize that increased nodule size at ultrasound does not predict malignancy and correlation between nodule size at ultrasound and pathologic exam is good. Resected thyroids with preoperative ultrasounds were identified. Nodule size at ultrasound, FNA diagnosis by Bethesda category, size at pathologic examination, and final histologic diagnosis were recorded. Nodule characteristics at ultrasound and FNA diagnoses were correlated with gross characteristics and histologic diagnoses. Nodules for which correlation could not be established were excluded. Of 1003 nodules from 659 patients, 26% were malignant. Nodules <2 cm had the highest malignancy rate (∼30%). Risk was similar (∼20%) for nodules ≥2 cm. Of the 548 subject to FNA, 38% were malignant. Decreasing malignancy rates were observed with increasing size (57% for nodules <1 cm to 20% for nodules >6 cm). At ultrasound size cutoffs of 2, 3, 4, and 5 cm, smaller nodules had higher malignancy rates than larger nodules. Of the 455 not subject to FNA, 11% were malignant. Ultrasound size alone is a poor predictor of malignancy, but a relatively good predictor of final pathologic size (R 2  = 0.748), with less correlation at larger sizes. In nodules subject to FNA, false negative diagnoses were highest (6-8%) in nodules 3-6 cm, mostly due to encapsulated follicular variant of papillary carcinoma. Thyroid nodule size is inversely related to malignancy risk, as larger nodules have lower malignancy rates. However, the relationship of size to malignancy varies by FNA status. All nodules (regardless of FNA status) demonstrate a risk trough at ≥2 cm. Nodules subject to FNA show step-wise decline in malignancy rates by size, demonstrating that size alone should not be considered as an independent risk factor. Size at ultrasound shows relatively good correlation with final pathologic size. False negative rates are low in this series. Lesions with the appropriate constellation of clinical and radiographic findings should undergo FNA regardless of size. Both size and FNA diagnosis should influence the clinical decision-making process.

  8. Long-axis view for ultrasound-guided central venous catheter placement via the internal jugular vein.

    PubMed

    Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus

    2016-04-01

    In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.

  9. Endoscopic ultrasound-guided fine-needle aspiration for suspected malignancies adjacent to the gastrointestinal tract.

    PubMed

    Gambitta, Pietro; Armellino, Antonio; Forti, Edoardo; Vertemati, Maurizio; Colombo, Paola Enrica; Aseni, Paolo

    2014-07-14

    To investigate the impact of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in association with a multidisciplinary team evaluation for the detection of gastrointestinal malignancies. A cohort of 1019 patients with suspected malignant lesions adjacent to the gastrointestinal tract received EUS-FNA after a standardized multidisciplinary team evaluation (MTE) and were divided into 4 groups according to their specific malignant risk score (MRS). Patients with a MRS of 0 (without detectable risk of malignancy) received only EUS without FNA. For patients with a MRS score ranging from 1 (low risk) - through 2 (intermediate risk) - to 3 (high risk), EUS-FNA cytology of the lesion was planned for a different time and was prioritized for those patients at higher risk for cancer. The accuracy, efficiency and quality assessment for the early detection of patients with potentially curable malignant lesions were evaluated for the whole cohort and in the different classes of MRSs. The time to definitive cytological diagnosis (TDCD), accuracy, sensitivity, specificity, positive and negative predictive values, and the rate of inconclusive tests were calculated for all patients and for each MRS group. A total of 1019 patients with suspected malignant lesions were evaluated by EUS-FNA. In 515 patients of 616 with true malignant lesions the tumor was diagnosed by EUS-FNA; 421 patients with resectable lesions received early surgical treatment, and 94 patients received chemo-radiotherapy. The overall diagnostic accuracy for the 1019 lesions in which a final diagnosis was obtained by EUS-FNA was 0.95. When patients were stratified by MTE into 4 classes of MRSs, a higher rate of patients in the group with higher cancer risk (MRS-3) received early treatment and EUS-FNA showed the highest level of accuracy (1.0). TDCD was also shorter in the MRS-3 group. The number of patients who received surgical treatment or chemo-radiotherapy was significantly higher in the MRS-3 patient group (36.3% in MRS-3, 10.7% in MRS-2, and 3.5% in MRS-1). EUS-FNA can effectively detect a curable malignant lesions at an earlier time and at a higher rate in patients with a higher cancer risk that were evaluated using MTE.

  10. Diagnostic and Treatment Patterns Among Children, Adolescents, and Young Adults with Thyroid Cancer in Ontario: 1992-2010.

    PubMed

    Pole, Jason D; Zuk, Aleksandra M; Wasserman, Jonathan D

    2017-08-01

    Thyroid carcinoma is rare in young children, with a sharp increase in incidence among adolescents and young adults between 15 and 29 years of age. The incidence of thyroid carcinoma is increasing worldwide. Limited prospective population-based data are available to describe diagnostic and treatment practices in this age group. This study undertook a population-based review of thyroid carcinoma among 0- to 29-year-old individuals in Ontario, Canada, utilizing linked administrative data to describe the demographic and care patterns over nearly two decades. Cases from the Ontario Cancer Registry were identified and linked to administrative data sources at the Institute for Clinical Evaluative Sciences. Cases diagnosed prior to a patient's 30th birthday between 1992 and 2010 were considered eligible. Billing records identified ultrasonography, fine-needle aspiration biopsy, radioiodine therapy, and surgical approach. A total of 2552 patients aged 0-29 years were diagnosed with thyroid carcinoma during the study period. There was a 2.1-fold increase in standardized incidence rate over the 19 years of this study. Thyroid carcinoma was diagnosed subsequent to a prior malignancy in 47/2552 patients at a median interval of 11.6 years after initial cancer diagnosis. Seventeen individuals developed a second malignancy after treatment for thyroid carcinoma. Most patients (90.44%) underwent preoperative ultrasound (ranging from 1 to 13 preoperative studies). Preoperative thyroid scintigraphy was used in 44% of patients, with a significant decline in usage over the study period. Fine-needle aspiration biopsy usage rose by 20% over the study period, although 26% of patients had no biopsy prior to surgery. Primary total thyroidectomy followed by two-stage thyroidectomy were the most frequently performed procedures, and 56% of patients received therapeutic radioiodine. This study establishes a foundation of diagnostic and practice patterns over nearly two decades. The study corroborates, in the Ontario population, the rising incidence of thyroid carcinoma in children and adolescents and young adults. Finally, it identifies the use of multiple preoperative ultrasound studies, low rates of thyroid biopsy, and thyroid scintigraphy as targets to improve efficiencies of care and to reduce unnecessary healthcare expenditures through education, standardization of diagnostic approach, and possibly regionalization of care.

  11. How Much Volume of Local Anesthesia and How Long Should You Wait After Injection for an Effective Wrist Median Nerve Block?

    PubMed

    Lovely, Lyndsay M; Chishti, Yasmin Z; Woodland, Jennifer L; Lalonde, Donald H

    2018-05-01

    Many surgeons and emergentologists use non-ultrasound-guided wrist nerve blocks. There is little evidence to guide the ideal volume of local anesthesia or how long we should wait after injection before performing pain-free procedures. This pilot study examined time to maximal anesthesia to painful needle stick in 14 volunteer participants receiving bilateral wrist blocks of 6 versus 11 mL of local. One surgeon performed all 14 bilateral wrist median nerve blocks in participants who remained blinded until after bandages were applied to their wrist. No one could see which wrist received the larger 11-mL volume injection versus the 6-mL block. Blinded sensory assessors then measured perceived maximal numbness time and numbness to needle stick pain in the fingertips of the median nerve distribution. Failure to get a complete median nerve block occurred in seven of fourteen 6-mL wrist blocks versus failure in only one of fourteen 11-mL blocks. Perceived maximal numbness occurred at roughly 40 minutes after injection, but actual numbness to painful needle stick took around 100 minutes. Incomplete median nerve numbness occurred with both 6- and 11-mL non-ultrasound-guided blocks at the wrist. In those with complete blocks, it took a surprisingly long time of 100 minutes for maximal anesthesia to occur to painful needle stick stimuli to the fingertips of the median nerve distribution. Non-ultrasound-guided median nerve blocks at the wrist as described in this article lack reliability and take too long to work.

  12. Tracheobronchial puncture-site nodular reaction (TPNR) following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): Systematic review of case reports.

    PubMed

    Madan, Karan; Tiwari, Pavan; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR) with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  13. Design and fabrication of PZN-7%PT single crystal high frequency angled needle ultrasound transducers.

    PubMed

    Zhou, Qifa; Wu, Dawei; Jin, Jing; Hu, Chang-hong; Xu, Xiaochen; Williams, Jay; Cannata, Jonathan M; Lim, Leongchew; Shung, K Kirk

    2008-01-01

    A high-frequency angled needle ultrasound transducer with an aperture size of 0.4 x 0.56 mm2 was fabricated using a lead zinc niobate-lead titanate (PZN- 7%PT) single crystal as the active piezoelectric material. The single crystal was bonded to a conductive silver particle matching layer and a conductive epoxy backing material through direct contact curing. A parylene outer matching layer was formed by vapor deposition. Angled needle probe configuration was achieved by dicing at 45 degrees to the single crystal poling direction to satisfy a clinical request for blood flow measurement in the posterior portion of the eye. The electrical impedance magnitude and phase of the transducer were 42 Omega and -63 degrees , respectively. The measured center frequency and the fractional bandwidth at -6 dB were 43 MHz and 45%, respectively. The two-way insertion loss was approximately 17 dB. Wire phantom imaging using fabricated PZN-7%PT single crystal transducers was obtained and spatial resolutions were assessed.

  14. Segmentation of prostate biopsy needles in transrectal ultrasound images

    NASA Astrophysics Data System (ADS)

    Krefting, Dagmar; Haupt, Barbara; Tolxdorff, Thomas; Kempkensteffen, Carsten; Miller, Kurt

    2007-03-01

    Prostate cancer is the most common cancer in men. Tissue extraction at different locations (biopsy) is the gold-standard for diagnosis of prostate cancer. These biopsies are commonly guided by transrectal ultrasound imaging (TRUS). Exact location of the extracted tissue within the gland is desired for more specific diagnosis and provides better therapy planning. While the orientation and the position of the needle within clinical TRUS image are limited, the appearing length and visibility of the needle varies strongly. Marker lines are present and tissue inhomogeneities and deflection artefacts may appear. Simple intensity, gradient oder edge-detecting based segmentation methods fail. Therefore a multivariate statistical classificator is implemented. The independent feature model is built by supervised learning using a set of manually segmented needles. The feature space is spanned by common binary object features as size and eccentricity as well as imaging-system dependent features like distance and orientation relative to the marker line. The object extraction is done by multi-step binarization of the region of interest. The ROI is automatically determined at the beginning of the segmentation and marker lines are removed from the images. The segmentation itself is realized by scale-invariant classification using maximum likelihood estimation and Mahalanobis distance as discriminator. The technique presented here could be successfully applied in 94% of 1835 TRUS images from 30 tissue extractions. It provides a robust method for biopsy needle localization in clinical prostate biopsy TRUS images.

  15. Biospecimen repositories and cytopathology.

    PubMed

    Krishnamurthy, Savitri

    2015-03-01

    Biospecimen repositories are important for the advancement of biomedical research. Literature on the potential for biobanking of fine-needle aspiration, gynecologic, and nongynecologic cytology specimens is very limited. The potential for biobanking of these specimens as valuable additional resources to surgically excised tissues appears to be excellent. The cervicovaginal specimens that can be used for biobanking include Papanicolaou-stained monolayer preparations and residual material from liquid-based cytology preparations. Different types of specimen preparations of fine-needle aspiration and nongynecologic specimens, including Papanicolaou-stained and Diff-Quik-stained smears, cell blocks. and dedicated passes/residual material from fine-needle aspiration stored frozen in a variety of solutions, can be used for biobanking. Because of several gaps in knowledge regarding the standard of operative procedures for the procurement, storage, and quality assessment of cytology specimens, further studies as well as national conferences and workshops are needed not only to create awareness but also to facilitate the use of cytopathology specimens for biobanking. © 2014 American Cancer Society.

  16. Update on Molecular Testing for Cytologically Indeterminate Thyroid Nodules.

    PubMed

    Nishino, Michiya; Nikiforova, Marina

    2018-04-01

    - Approximately 15% to 30% of thyroid nodules that undergo fine-needle aspiration are classified as cytologically indeterminate, presenting management challenges for patients and clinicians alike. During the past several years, several molecular tests have been developed to reduce the diagnostic uncertainty of indeterminate thyroid fine-needle aspirations. - To review the methodology, clinical validation, and recent peer-reviewed literature for 4 molecular tests that are currently marketed for cytologically indeterminate thyroid fine-needle aspiration specimens: Afirma, ThyroSeq, ThyGenX/ThyraMIR, and RosettaGX Reveal. - Peer-reviewed literature retrieved from PubMed search, data provided by company websites and representatives, and authors' personal experiences. - The 4 commercially available molecular tests for thyroid cytology offer unique approaches to improve the risk stratification of thyroid nodules. Familiarity with data from the validation studies as well as the emerging literature about test performance in the postvalidation setting can help users to select and interpret these tests in a clinically meaningful way.

  17. Needle detection in ultrasound using the spectral properties of the displacement field: a feasibility study

    NASA Astrophysics Data System (ADS)

    Beigi, Parmida; Salcudean, Tim; Rohling, Robert; Lessoway, Victoria A.; Ng, Gary C.

    2015-03-01

    This paper presents a new needle detection technique for ultrasound guided interventions based on the spectral properties of small displacements arising from hand tremour or intentional motion. In a block-based approach, the displacement map is computed for each block of interest versus a reference frame, using an optical flow technique. To compute the flow parameters, the Lucas-Kanade approach is used in a multiresolution and regularized form. A least-squares fit is used to estimate the flow parameters from the overdetermined system of spatial and temporal gradients. Lateral and axial components of the displacement are obtained for each block of interest at consecutive frames. Magnitude-squared spectral coherency is derived between the median displacements of the reference block and each block of interest, to determine the spectral correlation. In vivo images were obtained from the tissue near the abdominal aorta to capture the extreme intrinsic body motion and insertion images were captured from a tissue-mimicking agar phantom. According to the analysis, both the involuntary and intentional movement of the needle produces coherent displacement with respect to a reference window near the insertion site. Intrinsic body motion also produces coherent displacement with respect to a reference window in the tissue; however, the coherency spectra of intrinsic and needle motion are distinguishable spectrally. Blocks with high spectral coherency at high frequencies are selected, estimating a channel for needle trajectory. The needle trajectory is detected from locally thresholded absolute displacement map within the initial estimate. Experimental results show the RMS localization accuracy of 1:0 mm, 0:7 mm, and 0:5 mm for hand tremour, vibrational and rotational needle movements, respectively.

  18. Non-malignant breast papillary lesions - b3 diagnosed on ultrasound--guided 14-gauge needle core biopsy: analysis of 114 cases from a single institution and review of the literature.

    PubMed

    Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico

    2015-07-01

    One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).

  19. [Variations in the diagnostic confirmation process between breast cancer mass screening units].

    PubMed

    Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier

    2016-01-01

    To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  20. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat

    2008-02-15

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsymore » procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.« less

  1. Block of the superior cervical ganglion, description of a novel ultrasound-guided technique in human cadavers.

    PubMed

    Siegenthaler, Andreas; Haug, Matthias; Eichenberger, Urs; Suter, Marc Rene; Moriggl, Bernhard

    2013-05-01

    Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks. Wiley Periodicals, Inc.

  2. Role of endoscopic ultrasound in the molecular diagnosis of pancreatic cancer

    PubMed Central

    Bournet, Barbara; Gayral, Marion; Torrisani, Jérôme; Selves, Janick; Cordelier, Pierre; Buscail, Louis

    2014-01-01

    Pancreatic ductal adenocarcinoma remains one of the most deadly types of tumor. Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a safe, cost-effective, and accurate technique for evaluating and staging pancreatic tumors. However, EUS-FNA may be inconclusive or doubtful in up to 20% of cases. This review underlines the clinical interest of the molecular analysis of samples obtained by EUS-FNA in assessing diagnosis or prognosis of pancreatic cancer, especially in locally advanced tumors. On EUS-FNA materials DNA, mRNA and miRNA can be extracted, amplified, quantified and subjected to methylation assay. Kras mutation assay, improves diagnosis of pancreatic cancer. When facing to clinical and radiological presentations of pseudo-tumorous chronic pancreatitis, wild-type Kras is evocative of benignity. Conversely, in front of a pancreatic mass suspected of malignancy, a mutated Kras is highly evocative of pancreatic adenocarcinoma. This strategy can reduce false-negative diagnoses, avoids the delay of making decisions and reduces loss of surgical resectability. Similar approaches are conducted using analysis of miRNA expression as well as Mucin or markers of invasion (S100P, S100A6, PLAT or PLAU). Beyond the diagnosis approach, the prediction of response to treatment can be also investigated form biomarkers expression within EUS-FNA materials. PMID:25152579

  3. Warthin-Like Papillary Thyroid Carcinoma Associated with Lymphadenopathy and Hashimoto's Thyroiditis.

    PubMed

    González-Colunga, Karla Judith; Loya-Solis, Abelardo; Ceceñas-Falcón, Luis Ángel; Barboza-Quintana, Oralia; Rodríguez-Gutiérrez, René

    2015-01-01

    Defining the histologic variant of thyroid carcinoma is an important clinical implication as their progression, recurrence, aggressiveness, and prognosis differ. Warthin-like variant is one of the rarest histologic variants of papillary thyroid cancer. A 36-year-old female sought consult for assessment of a painless right neck tumor. High-resolution neck ultrasound revealed a right hypoechoic, 1.71 × 1.05 cm thyroid nodule. Ultrasound-guided fine-needle aspiration biopsy report was a Bethesda grade III. Thyroid function tests showed Hashimoto's thyroiditis. The patient underwent right hemithyroidectomy. Microscopically, the tumor was composed of papillae lined by cells with eosinophilic cytoplasm, nuclear chromatin clearing, grooves, and pseudoinclusions and a characteristic lymphoplasmacytic infiltrate of the papillae cores. Extension into the perithyroidal soft tissue and 3 ipsilateral lymph nodes was found to be positive for cancer. Warthin-like variant is an uncommon and relatively unknown variant of papillary thyroid carcinoma that has been usually associated with an excellent prognosis. Interestingly, BRAF mutations have been reported to be present in up to 75% of the patients. It is frequently associated with Hashimoto's thyroiditis and presents unique morphological features that make it recognizable on histologic examination. The cytological diagnosis is difficult to assess due to the overlap in its findings with the classical variant and Hashimoto's thyroiditis.

  4. Warthin-Like Papillary Thyroid Carcinoma Associated with Lymphadenopathy and Hashimoto's Thyroiditis

    PubMed Central

    González-Colunga, Karla Judith; Loya-Solis, Abelardo; Ceceñas-Falcón, Luis Ángel; Barboza-Quintana, Oralia; Rodríguez-Gutiérrez, René

    2015-01-01

    Defining the histologic variant of thyroid carcinoma is an important clinical implication as their progression, recurrence, aggressiveness, and prognosis differ. Warthin-like variant is one of the rarest histologic variants of papillary thyroid cancer. A 36-year-old female sought consult for assessment of a painless right neck tumor. High-resolution neck ultrasound revealed a right hypoechoic, 1.71 × 1.05 cm thyroid nodule. Ultrasound-guided fine-needle aspiration biopsy report was a Bethesda grade III. Thyroid function tests showed Hashimoto's thyroiditis. The patient underwent right hemithyroidectomy. Microscopically, the tumor was composed of papillae lined by cells with eosinophilic cytoplasm, nuclear chromatin clearing, grooves, and pseudoinclusions and a characteristic lymphoplasmacytic infiltrate of the papillae cores. Extension into the perithyroidal soft tissue and 3 ipsilateral lymph nodes was found to be positive for cancer. Warthin-like variant is an uncommon and relatively unknown variant of papillary thyroid carcinoma that has been usually associated with an excellent prognosis. Interestingly, BRAF mutations have been reported to be present in up to 75% of the patients. It is frequently associated with Hashimoto's thyroiditis and presents unique morphological features that make it recognizable on histologic examination. The cytological diagnosis is difficult to assess due to the overlap in its findings with the classical variant and Hashimoto's thyroiditis. PMID:25821606

  5. Laser, radiofrequency, and ethanol ablation for the management of thyroid nodules.

    PubMed

    Papini, Enrico; Gugliemi, Rinaldo; Pacella, Claudio Maurizio

    2016-10-01

    The majority of benign thyroid nodules are nearly asymptomatic, remain stable in size, and do not require treatment. However, a minority of patients with growing nodules may complain of local symptoms or have cosmetic concerns, and thus seek surgical consultation. The timely use of ultrasound-guided minimally invasive procedures can change the natural history of benign enlarging thyroid nodules. The procedures produce persistent shrinkage of thyroid nodules and are associated with improvement of local symptoms. Among the various procedures, percutaneous ethanol injection represents the first-line treatment for relapsing thyroid cysts. In solid nonfunctioning nodules, laser and radiofrequency ablation produces a more than 50% reduction in nodular volume that remains persistent over several years. For hyperfunctioning nodules, thermal ablation techniques are not appropriate unless radioactive iodine is contraindicated or not accessible. MITs are best suited for the management of medium or large-sized nodules that are sonographically well visualized. Conversely, large nodules or nodular goiters that extend into the chest are difficult to treat. MITs are performed in outpatient clinics, are less expensive, and have a lower risk of complications, compared to surgery, and usually do not induce thyroid dysfunction. However, malignancy should be ruled out with a dedicated ultrasound neck assessment and repeat fine needle aspiration of the lesion before treatment.

  6. Elastographic techniques of thyroid gland: current status.

    PubMed

    Andrioli, Massimiliano; Persani, Luca

    2014-08-01

    Thyroid nodules are very common with malignancies accounting for about 5 %. Fine-needle biopsy is the most accurate test for thyroid cancer diagnosis. Elastography, a new technology directly evaluating the elastic property of the tissue, has been recently added to the diagnostic armamentarium of the endocrinologists as noninvasive predictor of thyroid malignancy. In this paper, we critically reviewed characteristics and applications of elastographic methods in thyroid gland. Elastographic techniques can be classified on the basis of the following: source-of-tissue compression (free-hand, carotid vibration, ultrasound pulses), processing time (real-time, off-line), stiffness expression (qualitative, semi-quantitative, or quantitative). Acoustic radiation force impulse and aixplorer shear wave are the newest and most promising quantitative elastographic methods. Primary application of elastography is the detection of nodular lesions suspicious for malignancy. Published data show a high sensitivity and negative predictive value of the technique. Insufficient data are available on the possible application of elastography in the differential diagnosis of indeterminate lesions and in thyroiditis. Elastography represents a noninvasive tool able to increase the performance of ultrasound in the selection of thyroid nodules at higher risk of malignancy. Some technical improvements and definition of more robust quantitative diagnostic criteria are required for assigning a definite role in the management of thyroid nodules and thyroiditis to elastography.

  7. Forward-viewing endoscopic ultrasound-guided NOTES interventions: A study on peritoneoscopic potential

    PubMed Central

    Jeong, Seung Uk; Aizan, Hassanuddin; Song, Tae Jun; Seo, Dong Wan; Kim, Su-Hui; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan

    2013-01-01

    AIM: To evaluate the feasibility of diagnostic and therapeutic transgastric (TG) peritoneoscopic interventions with a forward-viewing endoscopic ultrasound (FV-EUS). METHODS: This prospective endoscopic experimental study used an animal model. Combined TG peritoneoscopic interventions and EUS examination of the intra-abdominal organs were performed using an FV-EUS on 10 animal models (1 porcine and 9 canine). The procedures carried out include EUS evaluation and endoscopic biopsy of intraperitoneal organs, EUS-guided fine needle aspiration (EUS-FNA), EUS-guided radiofrequency ablation (EUS-RFA), and argon plasma coagulation (APC) for hemostatic control. The animals were kept alive for 7 d, and then necropsy was performed to evaluate results and complications. RESULTS: In all 10 animals, TG peritoneoscopy, followed by endoscopic biopsy for the liver, spleen, abdominal wall, and omentum, was performed successfully. APC helped control minor bleeding. Visualization of intra-abdominal solid organs with real-time EUS was accomplished with ease. Intraperitoneal EUS-FNA was successfully performed on the liver, spleen, and kidney. Similarly, a successful outcome was achieved with EUS-RFA of the hepatic parenchyma. No adverse events were recorded during the study. CONCLUSION: Peritoneoscopic natural orifice transluminal endoscopic surgery (NOTES) interventions through FV-EUS were feasible in providing evaluation and performing endoscopic procedures. It promises potential as a platform for future EUS-based NOTES. PMID:24222961

  8. Is axillary surgery beneficial for patients with adenoid cystic carcinoma of the breast?

    PubMed

    Welsh, Jessemae L; Keeney, Michael G; Hoskin, Tanya L; Glazebrook, Katrina N; Boughey, Judy C; Shah, Sejal S; Hieken, Tina J

    2017-11-01

    Adenoid cystic carcinoma (ACC) is a rare, typically triple-negative, breast cancer reported to have a favorable prognosis and low rate of nodal metastasis. No consensus guidelines exist for axillary staging and treatment. We identified all patients with ACC evaluated at our institution from January 1994 to August 2016. Patient, tumor, and treatment variables were abstracted and analyzed. We identified 20 pure ACCs (0.13% of all invasive breast cancers) with size range 0.2-4.8 cm, in 19 women, median age 59 years. Preoperative axillary ultrasound was normal in 10/13 women and suspicious in 3/13 who had a subsequent negative lymph node fine needle aspiration (FNA). Fifteen patients (75%) had sentinel lymph node surgery and were pathologically node-negative, while the remaining five had no axillary surgery. With 3.6 years median follow-up (range 0.2-38.6 years), three patients experienced an in-breast recurrence at 2, 16, and 17 years, respectively, while none recurred in regional nodes. We observed no cases of nodal metastasis in 20 consecutive cases of ACC of the breast. Preoperative axillary ultrasound with FNA of suspicious nodes accurately predicted pathologic nodal stage. These data suggest axillary surgery might be omitted safely in patients with pure ACC and a clinically negative axilla. © 2017 Wiley Periodicals, Inc.

  9. Automatic detection of a hand-held needle in ultrasound via phased-based analysis of the tremor motion

    NASA Astrophysics Data System (ADS)

    Beigi, Parmida; Salcudean, Septimiu E.; Rohling, Robert; Ng, Gary C.

    2016-03-01

    This paper presents an automatic localization method for a standard hand-held needle in ultrasound based on temporal motion analysis of spatially decomposed data. Subtle displacement arising from tremor motion has a periodic pattern which is usually imperceptible in the intensity image but may convey information in the phase image. Our method aims to detect such periodic motion of a hand-held needle and distinguish it from intrinsic tissue motion, using a technique inspired by video magnification. Complex steerable pyramids allow specific design of the wavelets' orientations according to the insertion angle as well as the measurement of the local phase. We therefore use steerable pairs of even and odd Gabor wavelets to decompose the ultrasound B-mode sequence into various spatial frequency bands. Variations of the local phase measurements in the spatially decomposed input data is then temporally analyzed using a finite impulse response bandpass filter to detect regions with a tremor motion pattern. Results obtained from different pyramid levels are then combined and thresholded to generate the binary mask input for the Hough transform, which determines an estimate of the direction angle and discards some of the outliers. Polynomial fitting is used at the final stage to remove any remaining outliers and improve the trajectory detection. The detected needle is finally added back to the input sequence as an overlay of a cloud of points. We demonstrate the efficiency of our approach to detect the needle using subtle tremor motion in an agar phantom and in-vivo porcine cases where intrinsic motion is also present. The localization accuracy was calculated by comparing to expert manual segmentation, and presented in (mean, standard deviation and root-mean-square error) of (0.93°, 1.26° and 0.87°) and (1.53 mm, 1.02 mm and 1.82 mm) for the trajectory and the tip, respectively.

  10. Influence of temperature, needle gauge and injection rate on the size distribution, concentration and acoustic responses of ultrasound contrast agents at high frequency.

    PubMed

    Sun, Chao; Panagakou, Ioanna; Sboros, Vassilis; Butler, Mairead B; Kenwright, David; Thomson, Adrian J W; Moran, Carmel M

    2016-08-01

    This paper investigated the influence of needle gauge (19G and 27G), injection rate (0.85ml·min(-1), 3ml·min(-1)) and temperature (room temperature (RT) and body temperature (BT)) on the mean diameter, concentration, acoustic attenuation, contrast to tissue ratio (CTR) and normalised subharmonic intensity (NSI) of three ultrasound contrast agents (UCAs): Definity, SonoVue and MicroMarker (untargeted). A broadband substitution technique was used to acquire the acoustic properties over the frequency range 17-31MHz with a preclinical ultrasound scanner Vevo770 (Visualsonics, Canada). Significant differences (P<0.001-P<0.05) between typical in vitro setting (19G needle, 3ml·min(-1) at RT) and typical in vivo setting (27G needle, 0.85ml·min(-1) at BT) were found for SonoVue and MicroMarker. Moreover we found that the mean volume-based diameter and concentration of both SonoVue and Definity reduced significantly when changing from typical in vitro to in vivo experimental set-ups, while those for MicroMarker did not significantly change. From our limited measurements of Definity, we found no significant change in attenuation, CTR and NSI with needle gauge. For SonoVue, all the measured acoustic properties (attenuation, CTR and NSI) reduced significantly when changing from typical in vitro to in vivo experimental conditions, while for MicroMarker, only the NSI reduced, with attenuation and CTR increasing significantly. These differences suggest that changes in physical compression and temperature are likely to alter the shell structure of the UCAs resulting in measureable and significant changes in the physical and high frequency acoustical properties of the contrast agents under typical in vitro and preclinical in vivo experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Contrast-Enhanced Ultrasound Improves the Pathological Outcomes of US-Guided Core Needle Biopsy That Targets the Viable Area of Anterior Mediastinal Masses

    PubMed Central

    Zhou, Jian-hua; Shan, Hong-bo; Ou, Wei; Mo, Yun-xian; Xiang, Jin; Wang, Yu; Wang, Si-yu

    2018-01-01

    Based on the option that ultrasound-guided core needle biopsy (US-CNB) of the enhanced portion of anterior mediastinal masses (AMMs) identified by contrast-enhanced ultrasound (CEUS) would harvest viable tissue and benefit the histological diagnoses, a retrospective study was performed to elucidate the correlation between the prebiopsy CEUS and diagnostic yield of AMMs and found that CEUS potentially improved the diagnostic yield of AMMs compared with conventional US with a significant increase in the cellularity of samples. Furthermore, the marginal blood flow signals and absence of necrosis can predict the diagnostic yield of AMM. It was concluded that US-CNB of the viable part of AMMs, as verified by CEUS, was able to harvest sufficient tissue with more cellularity that could be used for ancillary studies and improve the diagnostic yield. And CEUS was recommended to those patients with AMMs undergoing repeated US-CNB, with the absence of marginal blood signals or presence of necrosis. PMID:29581992

  12. Clinical research on intelligence seven needle therapy treated infants with brain damage syndrome.

    PubMed

    Liu, Zhen-Huan; Li, Ye-Rong; Lu, Yong-Lin; Chen, Jie-Kui

    2016-06-01

    To assess whether the intelligence seven needle therapy administered in infants with perinatal brain damage syndrome (BDS) as early intervention would improve patients' neural development. A randomized controlled trial was conducted. Sixty-four infants with BDS were randomly assigned to two groups: the comprehensive group and the control group. Both groups received routine early intervention; in addition, the comprehensive group received intelligence seven needle therapy. Before and after treatment, the Bayley Scale of Infant Development (BSID), Gesell Developmental Schedules, Gross Motor Function Measure (GMFM), transcranial doppler ultrasound (TCD), and cranial imaging examination were tested for contrast. After treatment, the comprehensive group showed significant difference in the Mental Development Index (MDI) scores of BSID compared with the control group (P<0.05), however, no significant discrepancy in psychomotor development index (PDI,P>0.05) was observed. The children's development quotients (DQ) of the comprehensive group exhibited a significant superiority in improving the social adaptation DQ of Gesell Developmental Schedules compared with the control group (P<0.01), as well as GMFM and linguistic and social intercourse (P<0.05). Again, no discrepancy in the fine movement DQ was found (P>0.05). The total scores of GMFM in the comprehensive group were higher than those in the control group (P<0.05). Comparing the two groups, the comprehensive group showed a significantly greater recovery rate than the control group on TCD after treatment (P<0.05). After 6-month follow-up, some recovery in both groups, specifically on broadening of brain outside space by cranial imaging examination were observed. The comprehensive group demonstrated a significantly greater recovery rate than the control group (P<0.05). The developmental level of intelligence, motion function, linguistic competence and social intercourse can be promoted for infants with perinatal BDS by treating with the intelligence seven needle therapy. This approach can improve the brain blood supply and promote the growth of frontal and parietal lobes.

  13. Fine-needle aspiration cytology of mucous retention cyst of the tongue: distinction from other cystic lesions of the tongue.

    PubMed

    De Las Casas, L E; Bardales, R H

    2000-05-01

    Mucous retention cyst (MRC) is a common submucosal lesion of the oral cavity that, when deeply seated, simulates a neoplasm. This report describes the fine-needle aspiration cytology findings of a lingual MRC of complex architecture and with metaplastic epithelium. In addition, we emphasize its cytologic differential diagnosis from other benign and malignant cystic lesions of the tongue. To the best of our knowledge, this is the first report of aspiration cytology of a complex MRC of the tongue. Copyright 2000 Wiley-Liss, Inc.

  14. Fine needle aspiration cytology of subcutaneous cysticercosis of the breast. Case report and pathogenic discussion.

    PubMed

    Vuong, P N

    1989-01-01

    A case of subcutaneous cysticercosis of the breast diagnosed by fine needle aspiration cytology is reported. The cytologic preparations showed the presence of many inflammatory cells mixed with spiked spherules resembling the rambutan tropical fruit. These spherules arose from the degenerated integument of the parasite found in the histologically excised cyst. They are suggestive of the presence of an encysted flat worm, but are not specific for cysticercosis, whose identification is based on the study of the cephalic extremity of the parasite.

  15. Painless giant cell thyroiditis diagnosed by fine needle aspiration and associated with intense thyroidal uptake of gallium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanders, L.R.; Moreno, A.J.; Pittman, D.L.

    1986-05-01

    A 52-year-old woman presented with fever, goiter, and no evidence of pain or tenderness in the thyroid. A diagnosis of silent thyroiditis was made after obtaining evidence of biochemical thyrotoxicosis, intense gallium-67 citrate thyroidal localization, and cytologic thyroiditis. Fine needle aspiration biopsy of the thyroid revealed numerous giant cells in all areas of the thyroid, typical of subacute thyroiditis. This is believed to be the first time painless thyroiditis is reported with the classic cytologic feature of painful subacute thyroiditis.

  16. Fine needle aspiration cytology.

    PubMed Central

    Lever, J V; Trott, P A; Webb, A J

    1985-01-01

    Fine needle aspiration cytology is an inexpensive, atraumatic technique for the diagnosis of disease sites. This paper describes the technique and illustrates how it may be applied to the management of tumours throughout the body. The limitations of the method, the dangers of false positive reports, and the inevitability of false negative diagnoses are emphasised. In a clinical context the method has much to offer by saving patients from inappropriate operations and investigations and allowing surgeons to plan quickly and more rationally. It is an economically valuable technique and deserves greater recognition. Images PMID:2578481

  17. EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope.

    PubMed

    Binmoeller, K F; Brand, B; Thul, R; Rathod, V; Soehendra, N

    1998-05-01

    A new mechanical sector scanning echoendoscope designed for EUS-guided, fine-needle aspiration biopsy (FNAB) was prospectively evaluated. The technical feasibility, safety, and histocytologic FNAB results are reported. Eighty-six patients underwent 106 FNAB procedures. The new echoendoscope has a 2.8 mm accessory channel and an elevator. Target sites: pancreas 58, lymph nodes 43, and miscellaneous lesions 5. Lesions were punctured with a 0.7 mm needle and submitted for cytologic and histologic examination. Definitive diagnosis was by surgery or clinical follow-up. The wide scanning field (250 degrees) enabled easy sonographic orientation for FNAB. Longitudinal needle visibility was "good" in 93% and 71% of transesophageal and transgastric procedures, respectively, but were compromised during most transduodenal procedures. Needle penetration of indurated pancreatic lesions failed in two patients, and in four additional patients pancreatic sampling succeeded only after a second attempt using an automated spring-loaded device. The mean number of passes was three. Ten percent of FNAB specimens were "inadequate"; excluding these, the diagnostic accuracy rate was 97%; sensitivity for malignancy was 88.5% and specificity was 100%. EUS-guided FNAB is feasible, safe, and accurate using the new mechanical puncture echoendoscope. Needle visibility needs to be improved, particularly for transduodenal FNAB.

  18. Do acute-care surgeons follow best practices for breast abscess management? A single-institution analysis of 325 consecutive cases.

    PubMed

    Barron, Alison Unzeitig; Luk, Stephen; Phelan, Herb A; Williams, Brian H

    2017-08-01

    The breast surgery community has adopted needle aspiration as the standard of care for breast abscesses, which have a size less than 5 cm on ultrasound, no skin changes, and fewer than 5 days of symptoms. Our acute-care surgery (ACS) service manages all breast abscess consults at our urban safety-net hospital. We undertook this descriptive study to identify the rate of operative incisions and drainage performed by ACS surgeons which were not compatible with best practices for breast abscess management. We performed a retrospective review of the electronic health records of all patients on whom the ACS service was consulted for a breast abscess at our urban safety-net hospital between January 2010 and December 2014. We collected data on patient demographics, breast skin characteristics, length of symptoms, ultrasound results, and treatment modality. A total of 325 patients with breast abscesses were evaluated by ACS, of whom 21 met the breast community's indications for needle aspiration. Of the overall 325 subject sample, 281 (86.5%) underwent incision and drainage (I&D), and 44 (13.5%) underwent bedside needle aspiration. Of the 281 patients that underwent I&D, 269 (95.7%) met the breast surgery community's indications for I&D due to either skin changes (n = 90, 33.5%), abscess >5 cm on ultrasound (n = 88, 32.7%), or symptoms >5 days (n = 238, 88.5%). Of the 44 patients that underwent needle aspiration, only 9 (20.5%) met the current practice indications for aspiration. Of the 44 patients that underwent aspiration, 28 (63.6%) failed and went on to have an operation. The majority of these failed aspirations had symptoms >5 days (23 patients, 82.1%) or had skin changes at presentation (1 patient, 3.6%) or an abscess >5 cm on ultrasound (5 patients, 17.9%). As judged by best practices promulgated by the breast surgery community, ACS surgeons do not show excessive rates of operative I&D of breast abscess and in fact seem to overutilize needle aspiration. To our knowledge, this is the largest single institution series of the management of breast abscesses by ACS surgeons in the literature. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. FNAC Versus Core Needle Biopsy: A Comparative Study in Evaluation of Palpable Breast Lump

    PubMed Central

    Saha, Abhijit; Mukhopadhyay, Madhumita; Sarkar, Koushik; Saha, Ashis Kumar; Sarkar, Diptendra KR

    2016-01-01

    Introduction Breast carcinoma is the most common malignant tumour and the leading cause of carcinoma death in women in world. The main purpose of FNAC or CNB of breast lumps is to confirm cancer preoperatively and to avoid unnecessary surgery in specific benign conditions. Aims and Objective The objective of the study was to compare between Fine Needle Aspiration Cytology (FNAC) and Core Needle Biopsy (CNB) in the diagnosis of breast carcinoma with final histological diagnosis from excision specimen as it is gold standard. Materials and Methods A prospective study was done on 50 cases. Patients undergoing all three procedures (Fine Needle Aspiration Cytology and Core Needle Biopsy done at Department of Pathology; subsequent excision surgeries done at Department of General Surgery) were selected. May Grunwald Giemsa (MGG) and Papaniculou (PAP) staining were performed on cytology smears. Haematoxylin and Eosin (H&E) staining was done on both the CNB and tissue specimens obtained from subsequent excision surgeries to see the histological features. Results FNAC showed sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 69%, 100%, 100%, 38.1%, and 74% respectively in diagnosing carcinoma. CNB had sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 88.3%, 100%, 100%, 53.3% and 86%. Both FNAC and CNB showed statistically significant correlation with confirmatory HPE of excision specimen (p-value <0.05) in the diagnosis of breast carcinoma. Conclusion Fine needle aspiration cytology (FNAC) is a rapid, less complicated, economical, reliable and relevant method for the preoperative pathological diagnosis of breast carcinoma in a developing nation like ours. If the initial FNAC is inadequate, core needle biopsy (CNB) can be a useful second line method of pathological diagnosis in order to minimize the chance of missed diagnosis of breast cancer. PMID:27042469

  20. Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance.

    PubMed

    Farsad, Khashayar; Fuss, Cristina; Kolbeck, Kenneth J; Barton, Robert E; Lakin, Paul C; Keller, Frederick S; Kaufman, John A

    2012-12-01

    To describe the use of intravascular ultrasound (US) guidance for creation of transjugular intrahepatic portosystemic shunts (TIPSs) in humans. The initial 25 cases of intravascular US-guided TIPS were retrospectively compared versus the last 75 conventional TIPS cases during the same time period at the same institution in terms of the number of needle passes required to establish portal vein (PV) access, fluoroscopy time, and needle pass-related complications. Intravascular US-guided TIPS creation was successful in all cases, and there was no statistically significant difference in number of needle passes, fluoroscopy time, or needle pass-related complications between TIPS techniques. Intravascular US-guided TIPS creation was successful in cases in which conventional TIPS creation had failed as a result of PV thrombosis or distorted anatomy. Intravascular US guidance for TIPS creation was additionally useful in a patient with Budd-Chiari syndrome and in a patient with intrahepatic tumors. Intravascular US is a safe and reproducible means of real-time image guidance for TIPS creation, equivalent in efficacy to conventional fluoroscopic guidance. Real-time sonographic guidance with intravascular US may prove advantageous for cases in which there is PV thrombus, distorted anatomy, Budd-Chiari syndrome, or hepatic tumors. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  1. Incorporation of 13C labeled Pinus ponderosa needle and fine root litter into soil organic matter measured by Py-GC/MS-C-IRMS

    NASA Astrophysics Data System (ADS)

    Mambelli, S.; Gleixner, G.; Dawson, T. E.; Bird, J. A.; Torn, M. S.

    2006-12-01

    Developing effective strategies for enhancing C storage in soils requires understanding the influence of plant C quality. In turn, plant C quality impacts the decay continuum between plant residue and humified, stable SOM. This remains one of the least understood aspects of soil biogeochemistry. We investigated the initial phase of incorporation of 13C labeled Pinus ponderosa needle and fine root litter into SOM. The two litter types were placed in separate microcosms in the A horizon in a temperate conifer soil. Curie-point pyrolysis-gas chromatography coupled with on-line mass spectrometry and isotope ratio mass spectrometry (Py-GC/MS-C- IRMS) were used to determine the identity and the 13C enrichment of pyrolysis products (fragments of carbohydrates, lignin, proteins and lipids). We compared the two initial litter types, needles and fine roots, to samples of the bulk soil (A horizon, < 2mm) and soil humin fraction (from chemical solubility) obtained from each microcosm 1.5y after litter addition. Pyrolysis of plant material and SOM produced 56 suitable products for isotopic analysis; of them, 15 occurred in both the litter and bulk soil, 7 in both the litter and the humin fraction and 9 in both bulk soil and the humin fraction. The pyrolysis products found in common in the plant and soil were related either to polysaccharides or were non-specific and could have originated from various precursors. The data suggest that the majority of plant inputs, both from needles or fine roots, were degraded very rapidly. In the humin fraction, the most recalcitrant pool of C in soil, with a measured turnover time of 260y (this soil), only products from the fragmentation of polysaccharides and alkyl-benzene compounds were found. Comparisons of the enrichment normalized by input level suggest little difference between the incorporation of C from needles versus fine roots into SOM. The most enriched fragments in the humin fraction were products from polysaccharides degradation, indicating a very important role of microbial processing in the stabilization of C in SOM.

  2. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems.

    PubMed

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA", which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%" on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples.

  3. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  4. The Accuracy of a Handheld Ultrasound Device for Neuraxial Depth and Landmark Assessment: A Prospective Cohort Trial.

    PubMed

    Seligman, Katherine M; Weiniger, Carolyn F; Carvalho, Brendan

    2017-08-30

    This study investigated the accuracy of a wireless handheld ultrasound with pattern recognition software that recognizes lumbar spine bony landmarks and measures depth to epidural space (Accuro, Rivanna Medical, Charlottesville, VA) (AU). AU measurements to epidural space were compared to Tuohy needle depth to epidural space (depth to loss of resistance at epidural placement). Data from 47 women requesting labor epidural analgesia were analyzed. The mean difference between depth to epidural space measured by AU versus needle depth was -0.61 cm (95% confidence interval, -0.79 to -0.44), with a standard deviation of 0.58 (95% confidence interval, 0.48-0.73). Using the AU-identified insertion point resulted in successful epidural placement at first attempt in 87% of patients, 78% without redirects.

  5. Novel use of combination of electromyography and ultrasound to guide quadratus lumborum block after open appendicectomy.

    PubMed

    Mullins, Cormac F; O'Brien, Conor; O'Connor, Therese C

    2017-05-15

    The quadratus lumborum (QL) block facilitates the administration of anaesthesia to the anterior abdominal wall. The use of ultrasound (US) improves the accuracy of the QL block and reduces the risk of adverse events. Electromyography (EMG) in combination with US for muscle plane blocks has not been described previously. We postulated that the addition of EMG-guided needle positioning might assist the execution of this block. This case report describes the first use of combined needle EMG and US to carry out a QL block performed for postoperative analgesia following an open appendicectomy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Extramedullary plasmacytoma. Fine needle aspiration findings.

    PubMed

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  7. Papular skin lesions: Clue to a recurrence of breast cancer on fine needle non-aspiration cytology (FNNAC)

    PubMed Central

    Afrose, Ruquiya; Akram, Mohammad; Siddiqui, Shahid Ali

    2015-01-01

    Cutaneous metastasis from underlying carcinoma is relatively uncommon in clinical practice. A high index of suspicion is required to diagnose these lesions, as these lesions can mimic benign skin lesions and clinical findings may be subtle. Fine needle aspiration cytology (FNAC) is commonly employed for diagnosing these skin lesions. However, it is often difficult to aspirate adequate material from small papular lesions. In these clinical situations, fine needle non-aspiration cytology (FNNAC) is proposed as an alternative procedure. FNNAC eliminates the negative suction pressure employed in FNAC and decreases the dilution of tumor cells by blood and hence yields adequate diagnostic material. We report here a case in which FNNAC was used in place of FNAC in diagnosing papular skin lesions. This procedure was carried out in a treated patient of carcinoma breast who was on regular follow-up and presented to us with a 20-day history of papular skin lesions over the chest and back. This article enlightens the clinicians about the utility of FNNAC, which is a relatively uncommon procedure. PMID:25948954

  8. Papular skin lesions: Clue to a recurrence of breast cancer on fine needle non-aspiration cytology (FNNAC).

    PubMed

    Afrose, Ruquiya; Akram, Mohammad; Siddiqui, Shahid Ali

    2015-01-01

    Cutaneous metastasis from underlying carcinoma is relatively uncommon in clinical practice. A high index of suspicion is required to diagnose these lesions, as these lesions can mimic benign skin lesions and clinical findings may be subtle. Fine needle aspiration cytology (FNAC) is commonly employed for diagnosing these skin lesions. However, it is often difficult to aspirate adequate material from small papular lesions. In these clinical situations, fine needle non-aspiration cytology (FNNAC) is proposed as an alternative procedure. FNNAC eliminates the negative suction pressure employed in FNAC and decreases the dilution of tumor cells by blood and hence yields adequate diagnostic material. We report here a case in which FNNAC was used in place of FNAC in diagnosing papular skin lesions. This procedure was carried out in a treated patient of carcinoma breast who was on regular follow-up and presented to us with a 20-day history of papular skin lesions over the chest and back. This article enlightens the clinicians about the utility of FNNAC, which is a relatively uncommon procedure.

  9. Polymerase chain reaction in the detection of tumor cells: new approaches in diagnosis and follow-up of patients with thyroid cancer.

    PubMed

    Bojunga, Jörg; Kusterer, Klaus; Schumm-Draeger, Petra-Maria; Usadel, Klaus-Henning

    2002-12-01

    Thyroid cancers are the most common endocrine malignancies and are being diagnosed with increasing frequency. In addition to other measures, diagnosis is based on fine-needle aspiration cytology examination. Recently, new assays using reverse transcription-polymerase chain reaction (PCR) are being tested to improve sensitivity and specificity of primary diagnosis and detection of recurrent thyroid cancer. In the preoperative diagnosis of thyroid cancer, several tissue- and/or tumor-specific mRNA have been described and in several cases, a higher sensitivity and specificity could be achieved using molecular techniques compared to conventional methods. In the postoperative follow-up of patients with thyroid cancer, conflicting data have been published and the use of PCR techniques revealed several problems of the molecular approach, which are based on some technical as well as biologic limitations. Despite these problems, which are discussed in detail in this review, molecular techniques may nevertheless improve the sensitivity and accuracy of fine-needle aspiration of thyroid nodules, fine-needle aspiration of metastases, and detection of recurrent disease in peripheral blood samples.

  10. Improvement of the Mair scoring system using structural equations modeling for classifying the diagnostic adequacy of cytology material from thyroid lesions.

    PubMed

    Kulkarni, H R; Kamal, M M; Arjune, D G

    1999-12-01

    The scoring system developed by Mair et al. (Acta Cytol 1989;33:809-813) is frequently used to grade the quality of cytology smears. Using a one-factor analytic structural equations model, we demonstrate that the errors in measurement of the parameters used in the Mair scoring system are highly and significantly correlated. We recommend the use of either a multiplicative scoring system, using linear scores, or an additive scoring system, using exponential scores, to correct for the correlated errors. We suggest that the 0, 1, and 2 points used in the Mair scoring system be replaced by 1, 2, and 4, respectively. Using data on fine-needle biopsies of 200 thyroid lesions by both fine-needle aspiration (FNA) and fine-needle capillary sampling (FNC), we demonstrate that our modification of the Mair scoring system is more sensitive and more consistent with the structural equations model. Therefore, we recommend that the modified Mair scoring system be used for classifying the diagnostic adequacy of cytology smears. Diagn. Cytopathol. 1999;21:387-393. Copyright 1999 Wiley-Liss, Inc.

  11. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    PubMed Central

    Raquel, Garza-Guajardo; Nora, Mendez-Olvera; Pablo, Flores-Gutierrez Juan; Silvia, Hernandez-Martinez; Michelle, Candanosa-Mc Cann; Jesús, Ancer-Rodriguez; Oralia, Barboza-Quintana

    2005-01-01

    Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures. PMID:16174298

  12. In-line positioning of ultrasound images using wireless remote display system with tablet computer facilitates ultrasound-guided radial artery catheterization.

    PubMed

    Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo

    2016-02-01

    Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.

  13. Implementation of a rotational ultrasound biomicroscopy system equipped with a high-frequency angled needle transducer--ex vivo ultrasound imaging of porcine ocular posterior tissues.

    PubMed

    Bok, Tae-Hoon; Kim, Juho; Bae, Jinho; Lee, Chong Hyun; Paeng, Dong-Guk

    2014-09-24

    The mechanical scanning of a single element transducer has been mostly utilized for high-frequency ultrasound imaging. However, it requires space for the mechanical motion of the transducer. In this paper, a rotational scanning ultrasound biomicroscopy (UBM) system equipped with a high-frequency angled needle transducer is designed and implemented in order to minimize the space required. It was applied to ex vivo ultrasound imaging of porcine posterior ocular tissues through a minimal incision hole of 1 mm in diameter. The retina and sclera for the one eye were visualized in the relative rotating angle range of 270°~330° and at a distance range of 6~7 mm, whereas the tissues of the other eye were observed in relative angle range of 160°~220° and at a distance range of 7.5~9 mm. The layer between retina and sclera seemed to be bent because the distance between the transducer tip and the layer was varied while the transducer was rotated. Certin features of the rotation system such as the optimal scanning angle, step angle and data length need to be improved for ensure higher accuracy and precision. Moreover, the focal length should be considered for the image quality. This implementation represents the first report of a rotational scanning UBM system.

  14. Implementation of a Rotational Ultrasound Biomicroscopy System Equipped with a High-Frequency Angled Needle Transducer — Ex Vivo Ultrasound Imaging of Porcine Ocular Posterior Tissues

    PubMed Central

    Bok, Tae-Hoon; Kim, Juho; Bae, Jinho; Lee, Chong Hyun; Paeng, Dong-Guk

    2014-01-01

    The mechanical scanning of a single element transducer has been mostly utilized for high-frequency ultrasound imaging. However, it requires space for the mechanical motion of the transducer. In this paper, a rotational scanning ultrasound biomicroscopy (UBM) system equipped with a high-frequency angled needle transducer is designed and implemented in order to minimize the space required. It was applied to ex vivo ultrasound imaging of porcine posterior ocular tissues through a minimal incision hole of 1 mm in diameter. The retina and sclera for the one eye were visualized in the relative rotating angle range of 270° ∼ 330° and at a distance range of 6 ∼ 7 mm, whereas the tissues of the other eye were observed in relative angle range of 160° ∼ 220° and at a distance range of 7.5 ∼ 9 mm. The layer between retina and sclera seemed to be bent because the distance between the transducer tip and the layer was varied while the transducer was rotated. Certin features of the rotation system such as the optimal scanning angle, step angle and data length need to be improved for ensure higher accuracy and precision. Moreover, the focal length should be considered for the image quality. This implementation represents the first report of a rotational scanning UBM system. PMID:25254305

  15. The sensitivity of pre-operative axillary staging in breast cancer: comparison of invasive lobular and ductal carcinoma.

    PubMed

    Topps, A; Clay, V; Absar, M; Howe, M; Lim, Y; Johnson, R; Bundred, N

    2014-07-01

    Axillary ultrasound (AUS) with fine-needle aspiration (FNA) biopsy of abnormal lymph nodes is important for pre-operative staging and planning the surgical management of the axilla. Invasive lobular carcinoma (ILC) metastases are thought to be difficult to detect because the cells are small and on cytology resemble lymphocytes. To investigate this we directly compared the sensitivity of pre-operative axillary staging between ILC and invasive ductal carcinoma (IDC). Consecutive patients that presented in a single breast unit with pure IDC between April 2005 and December 2006 and pure ILC between January 2008 and December 2012 were retrospectively identified from pathology records. Pre-operative axillary ultrasound and FNA biopsy results were compared with post-operative histopathology from the sentinel node biopsy (SNB) or axillary lymph node dissection (ALND). A total of 275 and 142 axillae were identified in the IDC and ILC groups respectively. In the node positive patients there was no significant difference in the sensitivity of AUS (IDC vs. ILC; 58.7% vs. 52.8%). However, there was a significant difference in the sensitivity of ultrasound-guided FNA biopsy of abnormal nodes (IDC vs. ILC; 98.4% vs. 53.6%; p < 0.001). AUS has comparative sensitivities between IDC and ILC populations. In contrast, FNA biopsy of abnormal axillary nodes is clearly less sensitive in the ILC group. In these patients, who have abnormal AUS, we suggest that a core biopsy is required to improve the pre-operative staging and prevent unnecessary surgical procedures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Economic impact of and satisfaction with a high resolution thyroid nodule clinic at the endocrinology department.

    PubMed

    Díaz-Soto, Gonzalo; Torres, Beatriz; López Gómez, Juan Jose; Gómez Hoyos, Emilia; Villar, Aurelia; Romero, Enrique; de Luis, Daniel A

    2016-10-01

    No conclusive data exist on the value of a high resolution thyroid nodule clinic for management of nodular thyroid disease. The aim of this study was to evaluate the economic impact of and user satisfaction with a high resolution thyroid nodule clinic (HRTNC) in coordination with primary care. A prospective, observational, descriptive study was conducted to analyze data from 3,726 patients (mean age 61±12 years; 85% women) evaluated at an HRTNC during 2014 and 2015. Demographic data (sex and age), number of ultrasound examinations and fine needle aspiration cytologies (FNAC), referral center and consultation type were assessed. In 2014 and 2015, 3,726 neck ultrasound examinations and 926 FNACs (3.8% rated as non-diagnostic) were performed. Among the 1,227 patients evaluated for the first time, 21.5% did not require a second endocrine appointment, which resulted in mean estimated savings of 14,354.55 euros. Of all patients, 41.1% were referred from primary care, 33.4% from endocrinology, and 26.5% from other specialties. As compared to 2013, the number of thyroid ultrasound examinations requested decreased by 65.3% and 59.7% in 2014 and 2015 respectively, with mean estimated savings of 137,563.92 euros. Mean user satisfaction assessed was 4.0 points (95% confidence interval, 3.7-4.3) on a 5-point scale. HRTNCs at endocrinology departments, coordinated with primary care, are a viable, cost-effective alternative with a positive user perception. Copyright © 2016 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Success rate of repeated fine needle aspiration biopsy of clinically suspicious thyroid nodules.

    PubMed

    Nagarajah, J; Farahati, J; Görges, R; Grabellus, F; Bockisch, A; Sheu-Grabellus, S-Y

    2012-01-01

    In this study we evaluated the success rate of double fine needle aspiration biopsy (FNAB) of clinically suspicious thyroid nodules in one session. The success rate of FNAB in clinical setting is quite low. There were several attempts made to improve the success rate of this method. It is anticipated that a double FNAB in one session would increase the success rate of FNAB. 176 consecutive patients (130 women, 46 men; mean age 56 years ± 11) with at least one clinically suspicious nodule were included in this study. Each individual nodule was biopsied twice (20G- and 21G-needle). In 33 patients, two suspicious nodules were biopsied, accounting for a total of 209 biopsied thyroid nodules. To evaluate the success rate the number of cell formations and the total number of cells in each cell formation were counted. The biopsy with the 20G needle provided in mean 40 cell cluster with a mean of 830 cells whereas the 21G needle provided in mean 41 cell cluster with a mean of 1010 cells. With the 20G needle the success rate was 73%, with the 21G needle 78% and the combination of the both biopsies provided a success rate of 87% (p = 0.01). Based on the number of cell formations and the total number of cells, the difference between the two needle sizes was not significant (p = 0.5 for cell formations and p = 0.9 for the total number of cells, respectively). A double FNAB of suspicious thyroid nodules in one session provides a higher success rate, and a 21G needle is sufficient enough.

  18. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.

    PubMed

    Baez, E; Huber, A; Vetter, M; Hackelöer, B-J

    2003-03-01

    The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are

  19. Ultrasound-Guided Vascular Access Simulator for Medical Training: Proposal of a Simple, Economic and Effective Model.

    PubMed

    Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio

    2017-03-01

    To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.

  20. Acupuncture sensation during ultrasound guided acupuncture needling

    PubMed Central

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  1. Needle biopsy for hepatic vitamin A levels in lions (Panthera leo).

    PubMed

    Shamir, Merav H; Rubin, Gal; Aizenberg, Zachi; Berkovich, Zipi; Reifen, Ram; Horowitz, Igal; Bdolah-Abram, Tali; Aroch, Itamar

    2012-06-01

    Hypovitaminosis A (HA)-related skull malformations resulting in neurologic abnormalities and death have been, and still are, reported in captive lions (Panthera leo) worldwide. Liver vitamin A (VA) concentration is the most reliable indicator of animals' VA status, and its assessment is essential in prevention and treatment of HA in lions. A percutaneous needle liver biopsy using high-performance liquid chromatography ultraviolet retinoid analysis for VA concentration measurement was validated. It was first assessed in vitro using chicken liver. Later, the safety and feasibility of ultrasound-guided percutaneous needle liver biopsy was assessed in living lions. Hepatic VA concentrations in lion liver were measured using the above laboratory method. Mean chicken hepatic VA concentration in needle biopsy (NB) and wedge biopsy (WB) of the same liver lobes were 108.66 and 60.89 microg/g wet tissue, respectively, and were significantly (P = 0.03) correlated (r = 0.74). The calculated linear regression for predicting VA concentration in WB using NB VA for chicken liver was 25.194 + 0.3234x NB (microg/g). Four ultrasound-guided percutaneous needle liver biopsies were obtained from each of the four lions under general anesthesia. Mean hepatic VA concentration was 8.25 microg/g wet tissue (range 1.43-25.29 microg/g). Mean serum VA concentration, measured in these four lions was 1,011.1 nmol/L with a standard deviation of 337.91 nmol/L (range 590.26-1,077.2 nmol/L). The lions recovered uneventfully, and no complications were observed during a 4-yr follow-up period. In conclusion, the percutaneous needle liver biopsy technique is a reliable, practical, safe tool for obtaining liver tissue samples antemortem for assessment of the VA status in lions and can be used in future studies.

  2. Time-reversal acoustics and ultrasound-assisted convection-enhanced drug delivery to the brain.

    PubMed

    Olbricht, William; Sistla, Manjari; Ghandi, Gaurav; Lewis, George; Sarvazyan, Armen

    2013-08-01

    Time-reversal acoustics is an effective way of focusing ultrasound deep inside heterogeneous media such as biological tissues. Convection-enhanced delivery is a method of delivering drugs into the brain by infusing them directly into the brain interstitium. These two technologies are combined in a focusing system that uses a "smart needle" to simultaneously infuse fluid into the brain and provide the necessary feedback for focusing ultrasound using time-reversal acoustics. The effects of time-reversal acoustics-focused ultrasound on the spatial distribution of infused low- and high-molecular weight tracer molecules are examined in live, anesthetized rats. Results show that exposing the rat brain to focused ultrasound significantly increases the penetration of infused compounds into the brain. The addition of stabilized microbubbles enhances the effect of ultrasound exposure.

  3. Role of fine needle aspiration cytology and cell block in diagnosis of scar endometriosis: A case report

    PubMed Central

    Dash, Sashibhusan; Panda, Sasmita; Rout, Niranjan; Samantaray, Sagarika

    2015-01-01

    Presence of endometrial glands and stroma in places other than the uterus is called endometriosis. It can be pelvic or extra-pelvic. Abdominal scar endometriosis is an extra-pelvic endometriosis that can occur after surgery involving the uterus. Post-caesarean section, scar endometriosis is a rare event. The diagnosis is frequently made only after excision of disease tissue. We present a case of post-caesarean section abdominal scar endometriosis presenting as a tumor on the abdominal wall, which was diagnosed by fine needle aspiration cytology and confirmed by cell block preparation. PMID:25948955

  4. Role of fine needle aspiration cytology in diagnosing filarial arm cysts.

    PubMed

    Tandon, Nishi; Bansal, Cherry; Sharma, Richa; Irfan, Sumaiya

    2013-05-17

    Filariasis is prevalent in tropical and subtropical areas and is endemic in regions of India. Lymphatic filariasis in India is caused mainly by two species of nematodes: Wuchereria bancrofti and Brugia malayi, which invade the human lymphatic system. We report two cases of superficial cystic lesions of the upper limb revealed on fine needle aspiration (FNA) to be clinically unsuspected filariasis. Despite similar aetiologies, both cases revealed variations in aspirate nature, smear morphology and peripheral blood findings. FNA provides definitive diagnosis and is an important tool for diagnosing soft tissue swellings owing to filariasis.

  5. A Novel Method of Diagnosing Aberrant Pancreas: Needle-based Confocal Laser Endomicroscopy.

    PubMed

    Yasuda, Muneji; Hara, Kazuo; Kurita, Yusuke; Tanaka, Hiroki; Obata, Masahiro; Kuraoka, Naosuke; Matsumoto, Shimpei; Ito, Ayako; Iwaya, Hiromichi; Toriyama, Kazuhiro; Okuno, Nozomi; Kuwahara, Takamichi; Hijioka, Susumu; Mizuno, Nobumasa; Onishi, Sachiyo; Hirayama, Yutaka; Ishihara, Makoto; Tanaka, Tsutomu; Tajika, Masahiro; Niwa, Yasumasa

    2018-05-18

    Aberrant pancreas is defined as pancreatic tissue present outside of the pancreas and is often found incidentally during esophagogastroduodenoscopy. Obtaining sufficient tissue to differentiate aberrant pancreas from other subepithelial lesions is sometimes difficult. Due to the lack of a definitive diagnosis, patients often undergo unnecessary surgery. We herein report the first case of aberrant pancreas in which the concomitant use of needle-based probe confocal laser endomicroscopy and fine-needle aspiration supported the final diagnosis. Needle-based probe confocal laser endomicroscopy provides a real-time in vivo histopathology evaluation and may be a feasible means of diagnosing aberrant pancreas.

  6. [Follicular thyroid tumor as a diagnostic and therapeutic problem].

    PubMed

    Król, Robert; Heitzman, Marek; Pawlicki, Jacek; Ziaja, Jacek; Cierpka, Lech

    2004-01-01

    Although the appearance of follicular thyroid tumors in the population is high, only a small part of them are malignant. Follicular tumors are built of follicular epithelial cells and are encapsulated. Cell atypia differentiates follicular adenoma from cancer. Follicular cancer is characterized by vascular invasion and causes metastases through blood vessels, mainly to lungs and bones. In the diagnosis of follicular thyroid neoplasm, pathological examination of postoperative material plays a leading role. In diagnosis before surgical treatment, physical examination, ultrasound (USG), and fine needle aspiration biopsy (FNAB) are of great importance. The choice of treatment in patients in which follicular neoplasm has been diagnosed by FNAB awakes controversies. In practice it is impossible to determine reliably before surgery whether the lesion is malignant or not. Because of the rare incidence of thyroid cancer in the general population, more and more authors tend to decide on partial resection of the thyroid gland and possible radicalization if cancer is diagnosed on paraffin specimen examination.

  7. Clinical approach to incidental pancreatic cysts

    PubMed Central

    Chiang, Austin L; Lee, Linda S

    2016-01-01

    The approach to incidentally noted pancreatic cysts is constantly evolving. While surgical resection is indicated for malignant or higher risk cysts, correctly identifying these highest risk pancreatic cystic lesions remains difficult. Using parameters including cyst size, presence of solid components, and pancreatic duct involvement, the 2012 International Association of Pancreatology (IAP) and the 2015 American Gastroenterological Association (AGA) guidelines have sought to identify the higher risk patients who would benefit from further evaluation using endoscopic ultrasound (EUS). Not only can EUS help further assess the presence of solid component and nodules, but also fine needle aspiration of cyst fluid aids in diagnosis by obtaining cellular, molecular, and genetic data. The impact of new endoscopic innovations with novel methods of direct visualization including confocal endomicroscopy require further validation. This review also highlights the differences between the 2012 IAP and 2015 AGA guidelines, which include the thresholds for sending patients for EUS and surgery and methods, interval, and duration of surveillance for unresected cysts. PMID:26811661

  8. Cystic lesions of the pancreas

    PubMed Central

    Karoumpalis, Ioannis; Christodoulou, Dimitrios K.

    2016-01-01

    Different types of benign or malignant cystic lesions can be observed in the pancreas. Pancreatic cystic lesions are classified under pathology terms into simple retention cysts, pseudocysts and cystic neoplasms. Mucinous cystic neoplasm is a frequent type of cystic neoplasm and has a malignant potential. Serous cystadenoma follows in frequency and is usually benign. Intraductal papillary mucinous neoplasms are the most commonly resected cystic pancreatic neoplasms characterized by dilated segments of the main pancreatic duct and/or side branches, the wall of which is covered by mucus secreting cells. These neoplasms can occupy the pancreatic head or any part of the organ. Solid pseudopapillary tumor is rare, has a low tendency for malignancy, and is usually located in the pancreatic body or tail. Endoscopic ultrasound with the use of fine-needle aspiration and cytology permits discrimination of those lesions. In this review, the main characteristics of those lesions are presented, as well as recommendations regarding their follow up and management according to recent guidelines. PMID:27065727

  9. Challenges in diagnosis of pancreatic cancer.

    PubMed

    Zhang, Lulu; Sanagapalli, Santosh; Stoita, Alina

    2018-05-21

    Pancreatic cancer is a growing source of cancer related death, yet has poor survival rates which have not improved in the last few decades. Its high mortality rate is attributed to pancreatic cancer biology, difficulty in early diagnosis and the lack of standardised international guidelines in assessing suspicious pancreatic masses. This review aims to provide an update in the current state of play in pancreatic cancer diagnosis and to evaluate the benefits and limitations of available diagnostic technology. The main modalities discussed are imaging with computed tomography, magnetic resonance imaging, endoscopic ultrasound and positron emission tomography and tissue acquisition with fine needle aspiration. We also review the improvements in the techniques used for tissue acquisition and the opportunity for personalised cancer medicine. Screening of high risk individuals, promising biomarkers and common mimickers of pancreatic cancer are also explored, as well as suggestions for future research directions to allow for earlier detection of pancreatic cancer. Timely and accurate diagnosis of pancreatic cancer can lead to improvements in the current poor outcome of this disease.

  10. Label-free Imaging of Thyroid and Parathyroid Glands Using Coherent Anti-Stokes Raman Scattering (CARS) Microscopy

    NASA Astrophysics Data System (ADS)

    Weng, Sheng

    Thyroid and parathyroid glands play a vital role in regulating the body's metabolism and calcium levels. Surgical removal of the glands is the main treatment for both thyroid cancer and parathyroid adenoma. In thyroidectomy and parathyroidectomy, it's very important to differentiate thyroid, parathyroid, and the other tissues around the neck. Traditionally, physicians use ultrasound guided fine needle aspiration (FNA) to evaluate thyroid nodules, but up to 30% of FNA results are "inconclusive". The sestamibi scan can localize parathyroid adenoma, but currently it only has 50% accuracy. Here we applied the emerging CARS technique to image both thyroid and parathyroid tissues, which has potential to be used in real-time in vivo examination of different structures. We also developed algorithms to differentiate different cellular structures based on CARS images. When incorporated with a fiber optic endoscope in the future, CARS imaging technique can help surgeons identify cancerous thyroid tissue intraoperatively, preserve good parathyroid glands during thyroidectomy and find parathyroid adenoma during parathyroidectomy.

  11. Ectopic Thyroid Tissue in Submandibular and Infrahyoid Region

    PubMed Central

    Mutlu, Vahit

    2014-01-01

    The thyroid is the first endocrine gland to form during embryogenesis. At this stage, incomplete or anomalous migration of thyroid tissue causes ectopic localization of the gland. Submandibular ectopic thyroid tissue with a coexisting normally located thyroid gland is extremely rare. In this case aimed to present the findings of the 65-years-old female patient who is bilateral subtotal thyroidectomy operation performed for multinodular goiter of 12 years ago. Case, painless mass in the right submandibular and infrahyoid region for 6 months was admitted to our clinic with complaints. Result of contrast-enhanced neck computed tomography, ultrasound-guided fine-needle aspiration biopsy and thyroid scintigraphy were found of functional residual thyroid tissue in the normal localization as well as 2×3 cm mass in the submandibular area and 1×2 cm mass lesion in the infrahyoid region. The patient referred to excisional biopsy. Normal thyroid follicules and no evidence of malignancy were found in specimen pathologically. Postoperative follow-up of thyroid function tests were normal. PMID:25610328

  12. Therapy of Pancreatic Neuroendocrine Tumors: Fine Needle Intervention including Ethanol and Radiofrequency Ablation

    PubMed Central

    Lakhtakia, Sundeep

    2017-01-01

    Pancreatic neuroendocrine tumors (PNETs) are increasingly being detected, though usually as incidental findings. Majority of the PNETs are non-functional and surgical resection is the standard of care for most of them. However, in patients with small PNETs localized within the pancreas, who are unfit or unwilling for surgery, alternate methods of treatment are needed. Direct methods of ablation of PNETs, using either ethanol injection or radiofrequency ablation (RFA), are emerging as effective methods. The limited literature available as case reports or case series on endoscopic ultrasound (EUS)-guided local ablation using either ethanol or RFA has demonstrated safety and efficacy along with short- to medium-term sustained relief. Long-term benefits with these local ablative therapies are awaited. Comparative studies are needed to show which of these two competing technologies is superior. Finally, comparative trials of EUS-guided ablation with surgical resection in terms of efficacy and safety will ensure their place in the management algorithm. PMID:29207860

  13. Gastric carcinoma originating from the heterotopic submucosal gastric gland treated by laparoscopy and endoscopy cooperative surgery

    PubMed Central

    Imamura, Taisuke; Komatsu, Shuhei; Ichikawa, Daisuke; Kobayashi, Hiroki; Miyamae, Mahito; Hirajima, Shoji; Kawaguchi, Tsutomu; Kubota, Takeshi; Kosuga, Toshiyuki; Okamoto, Kazuma; Konishi, Hirotaka; Shiozaki, Atsushi; Fujiwara, Hitoshi; Ogiso, Kiyoshi; Yagi, Nobuaki; Yanagisawa, Akio; Ando, Takashi; Otsuji, Eigo

    2015-01-01

    Gastric carcinoma is derived from epithelial cells in the gastric mucosa. We reported an extremely rare case of submucosal gastric carcinoma originating from the heterotopic submucosal gastric gland (HSG) that was safely diagnosed by laparoscopy and endoscopy cooperative surgery (LECS). A 66-year-old man underwent gastrointestinal endoscopy, which detected a submucosal tumor (SMT) of 1.5 cm in diameter on the lesser-anterior wall of the upper gastric body. The tumor could not be diagnosed histologically, even by endoscopic ultrasound-guided fine-needle aspiration biopsy. Local resection by LECS was performed to confirm a diagnosis. Pathologically, the tumor was an intra-submucosal well differentiated adenocarcinoma invading 5000 μm into the submucosal layer. The resected tumor had negative lateral and vertical margins. Based on the Japanese treatment guidelines, additional laparoscopic proximal gastrectomy was curatively performed. LECS is a less invasive and safer approach for the diagnosis of SMT, even in submucosal gastric carcinoma originating from the HSG. PMID:26306144

  14. Primary thyroid tuberculosis: a rare etiology of hypothyroidism and anterior cervical mass mimicking carcinoma.

    PubMed

    Silva, Bradley Paulino da; Amorim, Erico Gurgel; Pavin, Elizabeth João; Martins, Antonio Santos; Matos, Patrícia Sabino de; Zantut-Wittmann, Denise Engelbrecht

    2009-06-01

    The involvement of the thyroid by tuberculosis (TB) is rare. Hypothyroidism caused by tissue destruction is an extremely rare report. Our aim was to report a patient with primary thyroid TB emphasizing the importance of diagnosis, despite the rarity of the occurrence. Women, 62 years old, showing extensive cervical mass since four months, referring lack of appetite, weight loss, dysphagia and dysphonia. Laboratorial investigation revealed primary hypothyroidism. Cervical ultrasound: expansive lesion in left thyroid lobe, involving adjacent muscle. Computed tomography scan: 13 cm diameter cervical mass with central necrosis. Fine needle biopsy: hemorrhagic material. total thyroidectomy, left radical neck dissection and protective tracheotomy. The pathological examination showed chronic granulomatous inflammatory process with areas of caseous necrosis and lymph node involvement. The thyroid baciloscopy was positive. Pulmonary disease was absent. The patient was treated with antituberculosis drugs. Thyroid TB is not frequent, and should be considered as differential diagnosis of hypothyroidism and anterior cervical mass.

  15. Sympathetic Chain Schwannoma Resembling Carotid Body Tumour.

    PubMed

    Najeeb, Tallat; Khan, Musaddiq

    2016-06-01

    Schwannomas are rare, benign nerve sheath tumours of parapharyngeal space. Differential diagnosis should include salivary gland tumours, paragangliomas, neurofibromas, and metastatic lymph nodes. The tumours may arise from vagus nerve and cervical sympathetic chain (CSC). Diagnosis is usually made by imaging techniques: contrast CT, magnetic resonance imaging (MRI), and magnetic resonance angiography (MRA). Fine needle aspiration cytology (FNAC) is useful diagnostic procedure but poor results are seen in neurogenic tumours. Rarely, a vascular CSC schwannoma at the level of carotid arteries bifurcation may mimic carotid body tumour (CBT) on imaging techniques, especially if they are vascular, causing splaying of internal and external carotid arteries. Clinically patient was asymptomatic except for a pulsatile swelling in neck for 5 years. The presented case resembled CBTclinically, on ultrasound and on imaging techniques causing splaying of carotid arteries. FNAC was inconclusive and was always hemorrhagic. During operation, it was found to be CSC schwannoma just posterior to carotid body. CSC was sacrificed and patient developed Horner syndrome postoperatively.

  16. Improved accuracy of ultrasound-guided therapies using electromagnetic tracking: in-vivo speed of sound measurements

    NASA Astrophysics Data System (ADS)

    Samboju, Vishal; Adams, Matthew; Salgaonkar, Vasant; Diederich, Chris J.; Cunha, J. Adam M.

    2017-02-01

    The speed of sound (SOS) for ultrasound devices used for imaging soft tissue is often calibrated to water, 1540 m/s1 , despite in-vivo soft tissue SOS varying from 1450 to 1613 m/s2 . Images acquired with 1540 m/s and used in conjunction with stereotactic external coordinate systems can thus result in displacement errors of several millimeters. Ultrasound imaging systems are routinely used to guide interventional thermal ablation and cryoablation devices, or radiation sources for brachytherapy3 . Brachytherapy uses small radioactive pellets, inserted interstitially with needles under ultrasound guidance, to eradicate cancerous tissue4 . Since the radiation dose diminishes with distance from the pellet as 1/r2 , imaging uncertainty of a few millimeters can result in significant erroneous dose delivery5,6. Likewise, modeling of power deposition and thermal dose accumulations from ablative sources are also prone to errors due to placement offsets from SOS errors7 . This work presents a method of mitigating needle placement error due to SOS variances without the need of ionizing radiation2,8. We demonstrate the effects of changes in dosimetry in a prostate brachytherapy environment due to patientspecific SOS variances and the ability to mitigate dose delivery uncertainty. Electromagnetic (EM) sensors embedded in the brachytherapy ultrasound system provide information regarding 3D position and orientation of the ultrasound array. Algorithms using data from these two modalities are used to correct bmode images to account for SOS errors. While ultrasound localization resulted in >3 mm displacements, EM resolution was verified to <1 mm precision using custom-built phantoms with various SOS, showing 1% accuracy in SOS measurement.

  17. Autonomic Responses to Ultrasound-Guided Percutaneous Needle Electrolysis: Effect of Needle Puncture or Electrical Current?

    PubMed

    García Bermejo, Paula; De La Cruz Torres, Blanca; Naranjo Orellana, José; Albornoz Cabello, Manuel

    2018-01-01

    The aim of this study was to establish if the changes in sympathetic and parasympathetic activity (analyzed through heart-rate variability [HRV]) during ultrasound (US)-guided percutaneous needle electrolysis (PNE) is due to the effect of needle puncture only or of the PNE technique per se where the puncture and galvanic current are combined. This was an experimental, case-control study that took place at the University of Seville. Subjects were 36 male footballers who were randomly allocated to three groups: a control group (CG; 12 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; a first experimental group (PNE group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE in the patellar tendon; and a second experimental group (needle group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE without electrical current in the patellar tendon. The outcome measures were the diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between CG measurements (baseline vs. intervention). The PNE group exhibited statistically significant increases in SD1 (p = 0.01) and SD2 (p = 0.004) and statistically significant decreases in SS and S/PS ratio (p = 0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. The needle group exhibited statistically significant increases in SD2 (p = 0.02) and statistically significant decreases in SS (p = 0.02), indicating decreased sympathetic activity. The application of the US-guided PNE technique caused a measurable increase in parasympathetic activity (detected by HRV), which was due to the combination of needle puncture and electric current.

  18. C-plane Reconstructions from Sheaf Acquisition for Ultrasound Electrode Vibration Elastography.

    PubMed

    Ingle, Atul; Varghese, Tomy

    2014-09-03

    This paper presents a novel algorithm for reconstructing and visualizing ablated volumes using radiofrequency ultrasound echo data acquired with the electrode vibration elastography approach. The ablation needle is vibrated using an actuator to generate shear wave pulses that are tracked in the ultrasound image plane at different locations away from the needle. This data is used for reconstructing shear wave velocity maps for each imaging plane. A C-plane reconstruction algorithm is proposed which estimates shear wave velocity values on a collection of transverse planes that are perpendicular to the imaging planes. The algorithm utilizes shear wave velocity maps from different imaging planes that share a common axis of intersection. These C-planes can be used to generate a 3D visualization of the ablated region. Experimental validation of this approach was carried out using data from a tissue mimicking phantom. The shear wave velocity estimates were within 20% of those obtained from a clinical scanner, and a contrast of over 4 dB was obtained between the stiff and soft regions of the phantom.

  19. Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a concise review.

    PubMed

    Aziz, Fahad

    2012-09-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) offers a minimally invasive alternative to mediastinoscopy with additional access to the hilar nodes, a better safety profile, and it removes the costs and hazards of theatre time and general anesthesia with comparable sensitivity, although the negative predictive value of mediastinoscopy (and sample size) is greater. EBUS- TBNA also obtains larger samples than conventional TBNA, has superior performance and theoretically is safer, allowing real-time sampling under direct vision. It can also have predictive value both in sonographic appearance of the nodes and histological characteristics. EBUS-TBNA is therefore indicated for NSCLC staging, diagnosis of lung cancer when there is no endobronchial lesion, and diagnosis of both benign (especially tuberculosis and sarcoidosis) and malignant mediastinal lesions. The procedure is different than for flexible bronchoscopy, takes longer, and requires more training. EBUS-TBNA is more expensive than conventional TBNA but can save costs by reducing the number of more costly mediastinoscopies. In the future, endobronchial ultrasound may have applications in airways disease and pulmonary vascular disease.

  20. Combined ultrasound and fluoroscopic guidance for radiofrequency ablation of the obturator nerve for intractable cancer-associated hip pain.

    PubMed

    Stone, Jonathan; Matchett, Gerald

    2014-01-01

    Management of pain from skeletal metastases is notoriously difficult. Case reports and case series have described radiofrequency ablation of the obturator nerve branches to the femoral head for treatment of intractable hip pain. Ablation of the obturator branches to the femoral head is technically difficult because of bony and vascular anatomy, including close proximity of the femoral vessels. Here we present the case of a 79-year-old woman with intractable right hip pain and inability to ambulate secondary to metastatic non-small cell lung cancer in the femoral head and acetabulum, treated with thermal radiofrequency ablation of the obturator and femoral nerve branches to the femoral head. Ablation of the obturator nerve was done via anterior placement of the radiofrequency needle under combined ultrasound and fluoroscopic guidance, passing the radiofrequency needle between the femoral artery and femoral vein. Real-time ultrasound guidance was used to avoid vascular puncture. Thermal radiofrequency ablation resulted in sustained pain relief, and resumption in the ability of the patient to ambulate. From this case we suggest that an anterior approach to the obturator nerve branches to the femoral head may be technically feasible using combined ultrasound and fluoroscopic guidance to avoid vascular puncture.

  1. Pre-procedure ultrasound-guided paramedian spinal anaesthesia at L5–S1: Is this better than landmark-guided midline approach? A randomised controlled trial

    PubMed Central

    Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2018-01-01

    Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151

  2. Intra-operative navigation of a 3-dimensional needle localization system for precision of irreversible electroporation needles in locally advanced pancreatic cancer.

    PubMed

    Bond, L; Schulz, B; VanMeter, T; Martin, R C G

    2017-02-01

    Irreversible electroporation (IRE) uses multiple needles and a series of electrical pulses to create pores in cell membranes and cause cell apoptosis. One of the demands of IRE is the precise needle spacing required. Two-dimensional intraoperative ultrasound (2-D iUS) is currently used to measure inter-needle distances but requires significant expertise. This study evaluates the potential of three-dimensional (3-D) image guidance for placing IRE needles and calculating needle spacing. A prospective clinical evaluation of a 3-D needle localization system (Explorer™) was evaluated in consecutive patients from April 2012 through June 2013 for unresectable pancreatic adenocarcinoma. 3-D reconstructions of patients' anatomy were generated from preoperative CT images, which were aligned to the intraoperative space. Thirty consecutive patients with locally advanced pancreatic cancer were treated with IRE. The needle localization system setup added an average of 6.5 min to each procedure. The 3-D needle localization system increased surgeon confidence and ultimately reduced needle placement time. IRE treatment efficacy is highly dependent on accurate needle spacing. The needle localization system evaluated in this study aims to mitigate these issues by providing the surgeon with additional visualization and data in 3-D. The Explorer™ system provides valuable guidance information and inter-needle distance calculations. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  3. Rapid detection of metastatic melanoma in lymph nodes using proton magnetic resonance spectroscopy of fine needle aspiration biopsy specimens.

    PubMed

    Lean, Cynthia L; Bourne, Roger; Thompson, John F; Scolyer, Richard A; Stretch, Jonathan; Li, Ling-Xi Lawrence; Russell, Peter; Mountford, Carolyn

    2003-06-01

    Accurate staging of patients with primary cutaneous melanoma includes assessment of regional lymph nodes for the presence of micrometastatic disease. Sentinel lymph node biopsy is highly accurate but is an invasive surgical procedure with a 5-10% complication rate, and requires labour-intensive and expensive histological examination to identify disease. A rapid, accurate and cost-effective non-surgical technique able to detect micrometastatic deposits of melanoma in regional lymph nodes would be of great benefit. Fine needle aspiration biopsies and tissue specimens were obtained from lymph nodes from 18 patients undergoing node resection for metastatic melanoma and five patients undergoing radical retropubic prostatectomy. One-dimensional proton magnetic resonance spectroscopy was undertaken at 360 MHz (8.5 T). Lymph nodes were cut into 3 mm thick slices and embedded. Four sequential 5 microm tissue sections were cut from each block and stained, with haematoxylin and eosin, for S100 protein, for HMB45, and again with haematoxylin and eosin, respectively. Proton magnetic resonance spectroscopy distinguished between benign and malignant lymph node tissue (P < 0.001, separate t-test) and benign and malignant lymph node fine needle aspiration biopsy (P < 0.012) based on the ratio of the integrals of resonances from lipid/other metabolites (1.8-2.5 p.p.m. region) and 'choline' (3.1-3.3 p.p.m. region). In conclusion, one-dimensional proton magnetic resonance spectroscopy on a simple fine needle aspiration biopsy can distinguish lymph nodes containing metastatic melanoma from uninvolved nodes, providing a rapid, accurate and cost-effective non-surgical technique to assess regional lymph nodes in patients with melanoma.

  4. Prostate Enlargement: Benign Prostatic Hyperplasia (BPH)

    MedlinePlus

    ... such as ultrasound, a computerized tomography scan, or magnetic resonance imaging to guide the biopsy needle into ... heats and destroys selected portions of prostate tissue. Shields protect the urethra from heat damage. Transurethral microwave ...

  5. Hyperthermia for treating cancer

    MedlinePlus

    ... forms of energy may be used, including: Radio waves Microwaves Ultrasound waves Heat may be delivered using: An external machine ... rectum. A needle-like probe to sends radio wave energy directly into the tumor to kill cancer ...

  6. Feasibility of ultrasound-guided sacroiliac joint injection considering sonoanatomic landmarks at two different levels in cadavers and patients.

    PubMed

    Klauser, Andrea; De Zordo, Tobias; Feuchtner, Gudrun; Sögner, Peter; Schirmer, Michael; Gruber, Johann; Sepp, Norbert; Moriggl, Bernhard

    2008-11-15

    Sacroiliitis is often caused by rheumatic diseases, and besides other therapeutic options, treatment consists of intraarticular injection of corticosteroids. The purpose of this study was to assess the feasibility of ultrasound (US)-guided sacroiliac joint (SI joint) injection at 2 different puncture levels in cadavers and patients when defined sonoanatomic landmarks were considered. After defining sonoanatomic landmarks, US-guided needle insertion was performed in 10 human cadavers (20 SI joints) at 2 different puncture sites. Upper level was defined at the level of the posterior sacral foramen 1 and lower level at the level of the posterior sacral foramen 2. In 10 patients with unilateral sacroiliitis, injection at the most feasible level was attempted. Computed tomography confirmed correct intraarticular needle placement in cadavers by showing the tip of the needle in the joint and intraarticular diffusion of contrast media in 16 (80%) of 20 SI joints (upper level 7 [70%] of 10; lower level 9 [90%] of 10). In all 4 cases in which needle insertion failed, intraarticular SI joint injection at the other level was successful. In patients, 100% of US-guided injections were successful (8 lower level, 2 upper level), with a mean pain relief of 8.6 after 3 months. US guidance of needle insertion into SI joints was feasible at both levels when defined sonoanatomic landmarks were used. If SI joint alterations do not allow for direct visualization of the dorsal joint space of the lower level, which is easier to access, the upper level might offer an appropriate alternative.

  7. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration With a 19-G Needle Device.

    PubMed

    Tremblay, Alain; McFadden, Seamus; Bonifazi, Martina; Luzzi, Valentina; Kemp, Samuel V; Gasparini, Stefano; Chee, Alex; MacEachern, Paul; Dumoulin, Elaine; A Hergott, Christopher; Shah, Pallav L

    2018-05-16

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration is a well-established first-line minimally invasive modality for mediastinal lymph node sampling. Although results are excellent overall, the technique underperforms in certain situations. We aimed to describe our results using a new 19-G EBUS-guided transbronchial needle aspiration device to determine safety and feasibility of this approach. We completed a retrospective chart review of all cases performed to the time of data analysis at each of 3 study sites. A total of 165 procedures were performed with a total of 297 individual lymph nodes or lesions sampled with the 19-G device by 10 bronchoscopists. Relatively large targets were selected for sampling with the device (mean lymph node size: 20.4 mm; lung lesions: 33.5 mm). A specific diagnosis was obtained in 77.3% of cases with an additional 13.6% of cases with benign lymphocytes, for a procedural adequacy rate of 90.9%. Procedure sample adequacy was 88.6% in suspected malignant cases, 91.0% in suspected sarcoidosis/lymphadenopathy cases, and 85.7% of cases with suspected lymphoma. On a per-node basis, a specific diagnosis was noted in 191/280 (68.2%) of samples, with an additional 61 showing benign lymphocytes for a per-node sample adequacy rate of 90%. One case (0.6%) of intraprocedure bleeding was noted. A new flexible 19-G EBUS needle was successfully and safely applied in a large patient cohort for sampling of lung and enlarged mediastinal lesions with high diagnostic rates across clinical indications.

  8. Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy

    PubMed Central

    Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter

    2016-01-01

    We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122

  9. Fine-needle aspiration cytology of hemangiopericytoma: report of two cases.

    PubMed

    Sawh, R N; Lele, S M; Borkowski, J; Ventura, K C; Zaharopoulos, P; Logroño, R

    2000-09-01

    The fine-needle aspiration biopsy (FNAB) findings in two cases of hemangiopericytoma (HP), arising in the parotid gland and on the inner chest wall, respectively, are reported. Smear preparations in each case showed cytologic features of an undifferentiated spindle-cell neoplasm, whereas a core needle biopsy specimen of the chest wall mass showed a spindle-cell tumor with a "staghorn-like" arrangement of endothelium-lined vascular channels. Immunostains performed on this core biopsy, and on the surgical resection specimens in both cases, showed positive staining of tumor cells for vimentin and CD34, with negative staining for a variety of smooth muscle, epithelial, neural, and neuroendocrine markers. Electron microscopy performed in one case further supported the diagnosis of HP. With adequate sampling and appropriate use of ancillary studies, a diagnosis of HP can be reliably suggested on the basis of FNAB and core biopsy of a soft-tissue mass. Copyright 2000 Wiley-Liss, Inc.

  10. CT-guided percutaneous fine-needle aspiration biopsy of the inferior vena cava wall: a posterior coaxial approach.

    PubMed

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L

    2010-02-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  11. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less

  12. CT-guided fine-needle biopsy of focal lung lesions as the method for reducing the number of invasive diagnostic procedures

    PubMed Central

    Chodorowska, Anna; Rzechonek, Adam; Dyła, Tomasz; Muszczyńska-Bernhard, Beata; Adamek, Jarosław

    2010-01-01

    Summary Background: CT-guided fine-needle biopsy (FNB) of focal lung lesions is one of the possibilities of obtaining histopathological diagnosis in pulmonary diseases. Its place in the algorithm is determined by the invasiveness. In case of no diagnosis after bronchoscopy or endobronchial ultrasonography (EBUS) guided biopsy, CT-guided FNB can become an alternative for more invasive procedures, such as open lung biopsy – thoracotomy. Material/Methods: Since January 2009 until February 2010, we performed 37 CT-guided FNB in 34 patients aged 31 to 76 (mean age 60.9). Among them, there were 16 women and 18 men. All patients underwent a standard chest CT with contrast medium injection. They were diagnosed with focal lesions and they were rejected from surgery as the primary method of treatment. During biopsy, the patient was positioned prone or supine, depending on the location of lesions. After performing a scout image and initial slices, we marked the level of biopsy, using a metal marker. Next, the biopsy needle was introduced under local anesthesia. When the obtained position of the needle in the lesion was correct, the specimen was taken. After needle removal, the patient was controlled for the presence of complications (i.e. pneumothorax). Biopsy time ranged from 10 to 50 minutes. Results: In 94.6% of biopsies, the specimens for histopathological and cytological examinations were obtained. In 22 (64.7%) patients, histopathological diagnoses (in 14 cases this was the non-small cell cancer and in 8, inflammatory lesions) were established which allowed us to resign from invasive thoracotomy and to introduce an appropriate treatment. In the remaining 12 patients, no diagnosis was established. Complications in the form of a minor pneumothorax occurred in 2 patients. Conclusions: Fine-needle biopsy of the focal lung lesions is an affective and a relatively safe method, which can replace the more invasive diagnostic thoracotomy in the majority of patients. PMID:22802777

  13. Endoscopic ultrasound comes of age: Mature, established, creative and here to stay!

    PubMed Central

    Bhutani, Manoop S.

    2014-01-01

    Research in endoscopic ultrasound (EUS) is alive and kicking! This paper will present recent interesting developments in EUS based on research presented at the Digestive Disease Week (DDW) held in Chicago in 2014. Endosonographers are looking at various techniques to improve yield of fine needle aspiration and core biopsies, assess circulating tumor cells, apply EUS for personalized medicine and develop devices to ensure the adequacy of sampling. EUS may open new vistas in understanding of neurogastroenterology and gastrointestinal motility disorders as discussed in this paper. EUS guided drainage of pancreatic fluid collections, bile duct and gallbladder is feasible, and many randomized trials are being done to compare different techniques. EUS guided delivery of fiducials, drugs, coils or chemo loaded beads in possible. EUS has come off age, has matured and is here to stay! The DDW in 2014 in Chicago was a very active year for EUS. There were numerous papers on different aspects of EUS, some perfecting and improving old techniques, others dealing with randomized trials and many with novel concepts. In this paper, I will highlight some of the papers that were presented. It is not possible to discuss all the abstracts in detail. I have, therefore, chosen selected papers in different aspects of EUS to give the readers a flavor of the kind of research that was presented at DDW. PMID:25184120

  14. High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes.

    PubMed

    Walk, Elyse L; McLaughlin, Sarah L; Weed, Scott A

    2015-07-25

    High-frequency ultrasound (HFUS) is widely employed as a non-invasive method for imaging internal anatomic structures in experimental small animal systems. HFUS has the ability to detect structures as small as 30 µm, a property that has been utilized for visualizing superficial lymph nodes in rodents in brightness (B)-mode. Combining power Doppler with B-mode imaging allows for measuring circulatory blood flow within lymph nodes and other organs. While HFUS has been utilized for lymph node imaging in a number of mouse  model systems, a detailed protocol describing HFUS imaging and characterization of the cervical lymph nodes in mice has not been reported. Here, we show that HFUS can be adapted to detect and characterize cervical lymph nodes in mice. Combined B-mode and power Doppler imaging can be used to detect increases in blood flow in immunologically-enlarged cervical nodes. We also describe the use of B-mode imaging to conduct fine needle biopsies of cervical lymph nodes to retrieve lymph tissue for histological  analysis. Finally, software-aided steps are described to calculate changes in lymph node volume and to visualize changes in lymph node morphology following image reconstruction. The ability to visually monitor changes in cervical lymph node biology over time provides a simple and powerful technique for the non-invasive monitoring of cervical lymph node alterations in preclinical mouse models of oral cavity disease.

  15. The accuracy of preoperative axillary nodal staging in primary breast cancer by ultrasound is modified by nodal metastatic load and tumor biology

    PubMed Central

    Dihge, Looket; Grabau, Dorthe A.; Rasmussen, Rogvi W.; Bendahl, Pär-Ola; Rydén, Lisa

    2016-01-01

    Abstract Background The outcome of axillary ultrasound (AUS) with fine-needle aspiration biopsy (FNAB) in the diagnostic work-up of primary breast cancer has an impact on therapy decisions. We hypothesize that the accuracy of AUS is modified by nodal metastatic burden and clinico-pathological characteristics. Material and methods The performance of AUS and AUS-guided FNAB for predicting nodal metastases was assessed in a prospective breast cancer cohort subjected for surgery during 2009–2012. Predictors of accuracy were included in multivariate analysis. Results AUS had a sensitivity of 23% and a specificity of 95%, while AUS-guided FNAB obtained 73% and 100%, respectively. AUS-FNAB exclusively detected macro-metastases (median four metastases) and identified patients with more extensive nodal metastatic burden in comparison with sentinel node biopsy. The accuracy of AUS was affected by metastatic size (OR 1.11), obesity (OR 2.46), histological grade (OR 4.43), and HER2-status (OR 3.66); metastatic size and histological grade were significant in the multivariate analysis. Conclusions The clinical utility of AUS in low-risk breast cancer deserves further evaluation as the accuracy decreased with a low nodal metastatic burden. The diagnostic performance is modified by tumor and clinical characteristics. Patients with nodal disease detected by AUS-FNAB represent a group for whom neoadjuvant therapy should be considered. PMID:27050668

  16. Quantitative analysis of breast cancer diagnosis using a probabilistic modelling approach.

    PubMed

    Liu, Shuo; Zeng, Jinshu; Gong, Huizhou; Yang, Hongqin; Zhai, Jia; Cao, Yi; Liu, Junxiu; Luo, Yuling; Li, Yuhua; Maguire, Liam; Ding, Xuemei

    2018-01-01

    Breast cancer is the most prevalent cancer in women in most countries of the world. Many computer-aided diagnostic methods have been proposed, but there are few studies on quantitative discovery of probabilistic dependencies among breast cancer data features and identification of the contribution of each feature to breast cancer diagnosis. This study aims to fill this void by utilizing a Bayesian network (BN) modelling approach. A K2 learning algorithm and statistical computation methods are used to construct BN structure and assess the obtained BN model. The data used in this study were collected from a clinical ultrasound dataset derived from a Chinese local hospital and a fine-needle aspiration cytology (FNAC) dataset from UCI machine learning repository. Our study suggested that, in terms of ultrasound data, cell shape is the most significant feature for breast cancer diagnosis, and the resistance index presents a strong probabilistic dependency on blood signals. With respect to FNAC data, bare nuclei are the most important discriminating feature of malignant and benign breast tumours, and uniformity of both cell size and cell shape are tightly interdependent. The BN modelling approach can support clinicians in making diagnostic decisions based on the significant features identified by the model, especially when some other features are missing for specific patients. The approach is also applicable to other healthcare data analytics and data modelling for disease diagnosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Relevance of testicular histopathology on prediction of sperm retrieval rates in case of non-obstructive and obstructive azoospermia.

    PubMed

    Cito, Gianmartin; Coccia, Maria E; Dabizzi, Sara; Morselli, Simone; Della Camera, Pier A; Cocci, Andrea; Criscuoli, Luciana; Picone, Rita; De Carlo, Candida; Nesi, Gabriella; Micelli, Elisabetta; Serni, Sergio; Carini, Marco; Natali, Alessandro

    2018-03-01

    The aim of our research was to establish the relevance of testicular histopathology on sperm retrieval after testicular sperm extraction in patients with non-obstructive azoospermia and in patients with obstructive azoospermia, who already underwent a previous failure testicular fine needle aspiration. We evaluated a total of 82 azoospermic men, underwent testicular sperm extraction, referring to the Assisted Reproductive Technology Centre of the University of Florence, Italy between January 2008 and March 2017. A general and genital physical examination, scrotal and trans-rectal ultrasound, semen analysis, hormone measurements, including follicle-stimulating hormone, luteinizing hormone and total testosterone, were collected. Successful sperm retrieval was obtained in 36 men of total (43.9%). Successful sperm retrieval was 29.5% in non-obstructive azoospermia patients, while men with obstructive azoospermia, who, underwent a previous failure testicular fine needle aspiration, had sperm retrieval in 86% of cases. Mean luteinizing hormone was 6.55 IU/L, total testosterone 4.70 ng/mL, right testicular volume 13.7 mL and left testicular volume 13.6 mL. Mean Follicle-stimulating hormone was 13.45 IU/L in patients with negative sperm retrieval and 8.18 IU/L in men with successful sperm retrieval. According to histology, 20.7% had normal spermatogenesis, 35.3% hypospermatogenesis, 35.3% maturation arrest and 8.5% Sertoli cell-only syndrome. Successful sperm retrieval was 88.2% in patients with normal spermatogenesis, 24.1% in the maturation arrest group and 48.27% in patients with hypospermatogenesis, while negative sperm retrieval was reported in Sertoli cell-only syndrome patients. Seven cases with maturation arrest showed a successful sperm retrieval. Testicular histopathology after testicular sperm extraction offers important information on prediction of sperm retrieval and can guide the surgeon in choosing the more suitable therapeutic practice.

  18. Novel and Practical Scoring Systems for the Diagnosis of Thyroid Nodules

    PubMed Central

    Wei, Ying; Zhou, Xinrong; Liu, Siyue; Wang, Hong; Liu, Limin; Liu, Renze; Kang, Jinsong; Hong, Kai; Wang, Daowen; Yuan, Gang

    2016-01-01

    Objective The clinical management of patients with thyroid nodules that are biopsied by fine-needle aspiration cytology and yield indeterminate results remains unsettled. The BRAF V600E mutation has dubious diagnostic value due to its low sensitivity. Novel strategies are urgently needed to distinguish thyroid malignancies from thyroid nodules. Design This prospective study included 504 thyroid nodules diagnosed by ultrasonography from 468 patients, and fine-needle aspiration cytology was performed under ultrasound guidance. Cytology and molecular analysis, including BRAF V600E, RET/PTC1 and RET/PTC3, were conducted simultaneously. The cytology, ultrasonography results, and mutational status were gathered and analyzed together. Predictive scoring systems were designed using a combination of diagnostic parameters for ultrasonography, cytology and genetic analysis. The utility of the scoring systems was analyzed and compared to detection using the individual methods alone or combined. Result The sensitivity of scoring systema (ultrasonography, cytology, BRAF V600E, RET/PTC) was nearly identical to that of scoring systemb (ultrasonography, cytology, BRAF V600E); these were 91.0% and 90.2%, respectively. These sensitivities were significantly higher than those obtained using FNAC, genetic analysis and US alone or combined; their sensitivities were 63.9%, 70.7% and 87.2%, respectively. Scoring systemc (ultrasonography, cytology) was slightly inferior to the former two scoring systems but still had relatively high sensitivity and specificity (80.5% and 95.1%, respectively), which were significantly superior to those of single cytology, ultrasonography or genetic analysis. In nodules with uncertainty cytology, scoring systema, scoring systemb and scoring systemc could elevate the malignancy detection rates to 69.7%, 69.7% and 63.6%, respectively. Conclusion These three scoring systems were quick for clinicians to master and could provide quantified information to predict the probability of malignant nodules. Scoring systemb is recommended for improving the detection rate among nodules of uncertain cytology. PMID:27654865

  19. TIRADS for sonographic assessment of hypofunctioning and indifferent thyroid nodules.

    PubMed

    Schenke, Simone; Rink, T; Zimny, M

    2015-01-01

    To test the feasibility of the Thyroid Imaging Reporting And Data System (TIRADS) according to Horvath and Kwak for the assessment of thyroid nodules. Retrospective analysis of patients with thyroid nodules applying the following inclusion criteria: B-mode-ultrasound, surgery and histological results. Thyroid nodules were classified as TIRADS 2, 3, 4A, 4B, 4C, 5 and 6. A total of 172 patients were included (133 women, 48 ± 13 years, 39 men, 49 ± 11 years) with 222 thyroid nodules (24.9 ± 11.5 mm). Final histological diagnosis revealed 203 benign nodules (91%) and 19 malignant nodules (9%; 18 papillary thyroid carcinoma, PTC, and one medullary thyroid carcinoma, MTC). One hundred and sixty thyroid nodules were hypofunctioning in 99mTc-pertechnetate-scintigraphy, 14 nodules were hyperfunctioning and 46 nodules were classified as indifferent. In two cases with small carcinoma < 1 cm 99mTc-pertechnetate-scintigraphy was not performed. According to Horvath, the prevalence of malignancy was 6.7% in TIRADS 2, 0% in 3, 1.9% in 4A, 33% in 4B, 12.5% in 5 and 100% in 6; 73 nodules (39%) were not clearly classifiable, including 3 carcinoma (4.1%). According to Kwak, the prevalence of malignancy was 6.9% in TIRADS 2, 0% in 3, 2% in 4A, 4.1% in 4B, 23.1% in 4C, and 100% in 5 and 6, respectively. Notably, in the subgroup of hot nodules, 11 (79%) were graded as TIRADS 4A or higher, and thus advisable for fine-needle aspiration biopsy in both TIRADS. The TIRADS described by Horvath is not practicable due to numerous unclassifiable nodules. The revised TIRADS published by Kwak is feasible and suitable to assess the prevalence of malignancy, but it cannot replace scintigraphic imaging. Fine-needle-biopsy is not necessary in nodules categorized as (K)TIRADS 3, 4A and 5.

  20. Fine-Needle Aspiration Biopsy of the Lymph Node: A Novel Tool for the Monitoring of Immune Responses after Skin Antigen Delivery.

    PubMed

    Tatovic, Danijela; Young, Philippa; Kochba, Efrat; Levin, Yotam; Wong, F Susan; Dayan, Colin M

    2015-07-01

    Assessment of immune responses in lymph nodes (LNs) is routine in animals, but rarely done in humans. We have applied minimally invasive ultrasound-guided fine-needle aspiration of the LN to a before-and-after study of the immune response to intradermally delivered Ag in healthy volunteers (n = 25). By comparison with PBMCs from the same individual, LN cells (LNCs) were characterized by reduced numbers of effector memory cells, especially CD8(+) TEMRA cells (3.37 ± 1.93 in LNCs versus 22.53 ± 7.65 in PBMCs; p = 0.01) and a marked increased in CD69 expression (27.67 ± 7.49 versus 3.49 ± 2.62%, LNCs and PBMCs, respectively; p < 0.0001). At baseline, there was a striking absence of IFN-γ ELISPOT responses to recall Ags (purified protein derivative, Tetanus toxoid, or flu/EBV/CMV viral mix) in LN, despite strong responses in the peripheral blood. However, 48 h after tuberculin purified protein derivative administration in the ipsilateral forearm resulting in a positive skin reaction, a clear increase in IFN-γ ELISPOT counts was seen in the draining LN but not in PBMCs. This response was lost by 5 d. These data suggest that the low levels of effector memory cells in the LN may explain the low background of baseline ELISPOT responses in LNs as compared with PBMCs, and the appearance of a response after 48 h is likely to represent migration of effector memory cells from the skin to the LN. Hence, it appears that the combination of intradermal Ag administration and draining LN sampling can be used as a sensitive method to probe the effector memory T cell repertoire in the skin. Copyright © 2015 by The American Association of Immunologists, Inc.

  1. Next-Generation Sequencing Identifies Gene Mutations That Are Predictive of Malignancy in Residual Needle Rinses Collected From Fine-Needle Aspirations of Thyroid Nodules.

    PubMed

    Fuller, Maren Y; Mody, Dina; Hull, April; Pepper, Kristi; Hendrickson, Heather; Olsen, Randall

    2018-02-01

    - Thyroid nodules have a prevalence of approximately 70% in adults. Fine-needle aspiration (FNA) is a minimally invasive, cost-effective, standard method to collect tissue from thyroid nodules for cytologic examination. However, approximately 15% of thyroid FNA specimens cannot be unambiguously diagnosed as benign or malignant. - To investigate whether clinically actionable data can be obtained using next-generation sequencing of residual needle rinse material. - A total of 24 residual needle rinse specimens with malignant (n = 6), indeterminate (n = 9), or benign (n = 9) thyroid FNA diagnoses were analyzed in our clinical molecular diagnostics laboratory using next-generation sequencing assays designed to detect gene mutations and translocations that commonly occur in thyroid cancer. Results were correlated with surgical diagnoses and clinical outcomes. - Interpretable data were generated from 23 of 24 residual needle rinse specimens. Consistent with its well-known role in thyroid malignancy, BRAF V600E mutations were detected in 4 malignant cases. An NRAS mutation was detected in 1 benign case. No mutations were detected from specimens with indeterminate diagnoses. - Our data demonstrate that residual thyroid FNA needle rinses are an adequate source of material for molecular diagnostic testing. Importantly, detection of a mutation implicated in thyroid malignancy was predictive of the final surgical diagnosis and clinical outcome. Our strategy to triage thyroid nodules with indeterminate cytology with molecular testing eliminates the need to perform additional FNA passes into dedicated media or to schedule additional invasive procedures. Further investigation with a larger sample size to confirm the clinical utility of our proposed strategy is underway.

  2. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    PubMed

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular adenomas, and 4 were adenomatous nodules. An aspirate of a parathyroid adenoma was misinterpreted as a macrofollicular lesion of the thyroid. Three microfollicular lesions on FNAB proved to be nodular hyperplasia on excision, and the other 11 were adenomas, 5 of them microfollicular. Average technologist time was significantly longer for thyroid FNABs than nonthyroid FNABs in 1993, but in the 1997 sample no significant difference was identified. Radiologically guided FNAB of the thyroid is a clinically useful procedure with a high correlation between benign lesions not needing excision (macrofollicular), and lesions that need excision (microfollicular/oxyphilic cell or malignant). Technologist time needed for immediate evaluation tends to decrease with increasing operator experience. Cancer (Cancer Cytopathol) Copyright 1999 American Cancer Society.

  3. Cost-effectiveness comparison between palpation- and ultrasound-guided thyroid fine-needle aspiration biopsies.

    PubMed

    Can, Ahmet Selçuk

    2009-05-16

    The aim of this study is to perform a cost-effectiveness comparison between palpation-guided thyroid fine-needle aspiration biopsies (P-FNA) and ultrasound-guided thyroid FNA biopsies (USG-FNA). Each nodule was considered as a case. Diagnostic steps were history and physical examination, TSH measurement, Tc99m thyroid scintigraphy for nodules with a low TSH level, initial P-FNA versus initial USG-FNA, repeat USG-FNA for nodules with initial inadequate P-FNA or USG-FNA, hemithyroidectomy for inadequate repeat USG-FNA. American Thyroid Association thyroid nodule management guidelines were simulated in estimating the cost of P-FNA strategy. American Association of Clinical Endocrinologists guidelines were simulated for USG-FNA strategy. Total costs were estimated by adding the cost of each diagnostic step to reach a diagnosis for 100 nodules. Strategy cost was found by dividing the total cost to 100. Incremental cost-effectiveness ratio (ICER) was calculated by dividing the difference between strategy cost of USG-FNA and P-FNA to the difference between accuracy of USG-FNA and P-FNA. A positive ICER indicates more and a negative ICER indicates less expense to achieve one more additional accurate diagnosis of thyroid cancer for USG-FNA. Seventy-eight P-FNAs and 190 USG-FNAs were performed between April 2003 and May 2008. There were no differences in age, gender, thyroid function, frequency of multinodular goiter, nodule location and diameter (median nodule diameter: 18.4 mm in P-FNA and 17.0 mm in USG-FNA) between groups. Cytology results in P-FNA versus USG-FNA groups were as follows: benign 49% versus 62% (p = 0.04), inadequate 42% versus 29% (p = 0.03), malignant 3% (p = 1.00) and indeterminate 6% (p = 0.78) for both. Eleven nodules from P-FNA and 18 from USG-FNA group underwent surgery. The accuracy of P-FNA was 0.64 and USG-FNA 0.72. Unit cost of P-FNA was 148 Euros and USG-FNA 226 Euros. The cost of P-FNA strategy was 534 Euros and USG-FNA strategy 523 Euros. Strategy cost includes the expense of repeat USG-FNA for initial inadequate FNAs and surgery for repeat inadequate USG-FNAs. ICER was -138 Euros. Universal application of USG-FNA for all thyroid nodules is cost-effective and saves 138 Euros per additional accurate diagnosis of benign versus malignant thyroid nodular disease. ClinicalTrials.gov, NCT00571090.

  4. Cost-effectiveness comparison between palpation- and ultrasound-guided thyroid fine-needle aspiration biopsies

    PubMed Central

    Can, Ahmet Selçuk

    2009-01-01

    Background The aim of this study is to perform a cost-effectiveness comparison between palpation-guided thyroid fine-needle aspiration biopsies (P-FNA) and ultrasound-guided thyroid FNA biopsies (USG-FNA). Methods Each nodule was considered as a case. Diagnostic steps were history and physical examination, TSH measurement, Tc99m thyroid scintigraphy for nodules with a low TSH level, initial P-FNA versus initial USG-FNA, repeat USG-FNA for nodules with initial inadequate P-FNA or USG-FNA, hemithyroidectomy for inadequate repeat USG-FNA. American Thyroid Association thyroid nodule management guidelines were simulated in estimating the cost of P-FNA strategy. American Association of Clinical Endocrinologists guidelines were simulated for USG-FNA strategy. Total costs were estimated by adding the cost of each diagnostic step to reach a diagnosis for 100 nodules. Strategy cost was found by dividing the total cost to 100. Incremental cost-effectiveness ratio (ICER) was calculated by dividing the difference between strategy cost of USG-FNA and P-FNA to the difference between accuracy of USG-FNA and P-FNA. A positive ICER indicates more and a negative ICER indicates less expense to achieve one more additional accurate diagnosis of thyroid cancer for USG-FNA. Results Seventy-eight P-FNAs and 190 USG-FNAs were performed between April 2003 and May 2008. There were no differences in age, gender, thyroid function, frequency of multinodular goiter, nodule location and diameter (median nodule diameter: 18.4 mm in P-FNA and 17.0 mm in USG-FNA) between groups. Cytology results in P-FNA versus USG-FNA groups were as follows: benign 49% versus 62% (p = 0.04), inadequate 42% versus 29% (p = 0.03), malignant 3% (p = 1.00) and indeterminate 6% (p = 0.78) for both. Eleven nodules from P-FNA and 18 from USG-FNA group underwent surgery. The accuracy of P-FNA was 0.64 and USG-FNA 0.72. Unit cost of P-FNA was 148 Euros and USG-FNA 226 Euros. The cost of P-FNA strategy was 534 Euros and USG-FNA strategy 523 Euros. Strategy cost includes the expense of repeat USG-FNA for initial inadequate FNAs and surgery for repeat inadequate USG-FNAs. ICER was -138 Euros. Conclusion Universal application of USG-FNA for all thyroid nodules is cost-effective and saves 138 Euros per additional accurate diagnosis of benign versus malignant thyroid nodular disease. Trial registration ClinicalTrials.gov, NCT00571090 PMID:19445710

  5. From basic concepts to emerging technologies in regional anesthesia.

    PubMed

    Dillane, Derek; Tsui, Ban C H

    2010-10-01

    The present article details how our understanding of the basic concepts of regional anesthesia has recently evolved. We will appraise current technological advances and question the commensurate nature of the relationship between tradition and innovation. Ultrasound localization has enhanced our understanding of the needle-nerve relationship. Intraneural injection of local anesthetic may occur with greater frequency than previously thought without inevitably leading to neurological complications. The ratio of neural to non-neural tissue varies both between and within nerves and may be an important determinant of neural injury. Ultrasonographic evidence of intraneural injection is subject to observer expertise and the resolution of the ultrasound image. Current ultrasound resolution capability does not reliably permit differentiation between intrafascicular and extrafascicular drug injection. Perineural electrical impedance may be a determinant of current threshold and conceivably distinguish between intraneural and extraneural tissue. Technology that enhances the sonographic image of both procedure needle and target nerve is the focus of current endeavors in ultrasound innovation.There is inconclusive evidence that the use of ultrasound technology has reduced the incidence of local anesthetic toxicity. Lipid emulsion therapy is now an accepted treatment for systemic local anesthetic toxicity. There are new reports on the development of an ultra long-acting local anesthetic agent that would permit lower doses and superannuate catheter-based continuous regional anesthesia techniques. Over the past decade, our understanding of the fundamental concepts of regional anesthesia continues to be challenged by emerging experimental and clinical evidence.

  6. Novel 3-D laparoscopic magnetic ultrasound image guidance for lesion targeting

    PubMed Central

    Sindram, David; McKillop, Iain H; Martinie, John B; Iannitti, David A

    2010-01-01

    Objectives: Accurate laparoscopic liver lesion targeting for biopsy or ablation depends on the ability to merge laparoscopic and ultrasound images with proprioceptive instrument positioning, a skill that can be acquired only through extensive experience. The aim of this study was to determine whether using magnetic positional tracking to provide three-dimensional, real-time guidance improves accuracy during laparoscopic needle placement. Methods: Magnetic sensors were embedded into a needle and laparoscopic ultrasound transducer. These sensors interrupted the magnetic fields produced by an electromagnetic field generator, allowing for real-time, 3-D guidance on a stereoscopic monitor. Targets measuring 5 mm were embedded 3–5 cm deep in agar and placed inside a laparoscopic trainer box. Two novices (a college student and an intern) and two experts (hepatopancreatobiliary surgeons) targeted the lesions out of the ultrasound plane using either traditional or 3-D guidance. Results: Each subject targeted 22 lesions, 11 with traditional and 11 with the novel guidance (n = 88). Hit rates of 32% (14/44) and 100% (44/44) were observed with the traditional approach and the 3-D magnetic guidance approach, respectively. The novices were essentially unable to hit the targets using the traditional approach, but did not miss using the novel system. The hit rate of experts improved from 59% (13/22) to 100% (22/22) (P < 0.0001). Conclusions: The novel magnetic 3-D laparoscopic ultrasound guidance results in perfect targeting of 5-mm lesions, even by surgical novices. PMID:21083797

  7. Peritoneal fluid analysis

    MedlinePlus

    ... at fluid that has built up in the space in the abdomen around the internal organs. This area is called the peritoneal space. ... sample of fluid is removed from the peritoneal space using a needle and syringe. Ultrasound is often ...

  8. Role of endoscopic ultrasonography in evaluation of metastatic lesions to the pancreas: a tertiary cancer center experience.

    PubMed

    Atiq, Muslim; Bhutani, Manoop S; Ross, William A; Raju, Gottumukkala S; Gong, Yun; Tamm, Eric P; Javle, Milind; Wang, Xuemei; Lee, Jeffrey H

    2013-04-01

    Metastatic lesions to the pancreas pose diagnostic challenges with regards to their differentiation from primary pancreatic cancer. Data on the yield of endoscopic ultrasonography (EUS)-guided fine-needle aspiration in detection of these lesions are limited. This is a retrospective review of 23 patients referred to a tertiary referral center for further evaluation of suspected pancreatic metastases. Main outcome measures were diagnostic yield of endoscopic ultrasonography-guided fine-needle aspiration in evaluation of metastatic lesions to the pancreas. Of 644 patients, 23 (3.6%) undergoing EUS of the pancreas were diagnosed to have metastatic disease to the pancreas based on clinical, radiological, and cytological results. Mean (SD) age was 64.3 (11.7) years. Of the 23 patients, 18 (78.3%) were asymptomatic. Mean (SD) size of lesion on EUS was 39.1 (19.9) mm. A diagnosis of malignant lesion was made in 21 of 23 cases, with a diagnostic accuracy of 91.3%. Metastatic lesions to the pancreas present as incidental, solitary mass lesions on staging or surveillance imaging. Endoscopic ultrasonography-guided fine-needle aspiration is an important tool in the characterization and further differentiation of metastatic lesions to the pancreas from primary pancreatic cancer.

  9. Unusual cases of metastases to the breast. A report of 17 cases diagnosed by fine needle aspiration.

    PubMed

    David, Odile; Gattuso, Paolo; Razan, Wafai; Moroz, Krzysztof; Dhurandhar, Nina

    2002-01-01

    Although nonmammary tumors metastatic to the breast are relatively uncommon, a correct diagnosis is essential to appropriate management. Radiologically these lesions are single, round, discrete lesions without the spiculations of primary malignancies. Fine needle aspiration biopsy (FNAB) may provide a definitive diagnosis, thereby sparing patients unnecessary surgery. Seventeen cases of nonmammary malignancies diagnosed by fine needle aspiration of the breast were identified in the cytopathology files at three different institutions from 1989 to 1999. Three of the cases are of particular interest, including a mucoepidermoid carcinoma of salivary gland origin and a small cell undifferentiated carcinoma of rectal origin, neither of which has been reported in the literature previously. The third case was a male with a breast mass that was originally thought to be primary based on clinical, cytologic and immunocytochemical features but subsequently was determined to be a metastasis from the lung. Virtually any malignancy may metastasize to the breast. FNAB is the best approach to the diagnosis of tumors that either clinically or radiographically are not typical of primary breast tumors. Extramammary neoplasms metastatic to the breast may be definitively diagnosed by FNAB, resulting in the most appropriate as well as cost-effective patient management.

  10. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    PubMed Central

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. PMID:25352966

  11. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    PubMed

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  12. Ultrasound-guided peripheral nerve interventions for common pain disorders

    PubMed Central

    Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh

    2018-01-01

    There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534

  13. MR-guided fine needle aspiration of breast lesions: Initial experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wald, D.S.; Weinreb, J.C.; Newstead, G.

    1996-01-01

    Fine needle aspiration (FNA) is a minimally invasive procedure that is used to obtain cytologic specimens of suspicious lesions in the breast. The goal of this study was to evaluate the logistics and limitations of MR-guided FNA using a prototype breast localization coil. MR-guided FNAs were attempted on 18 lesions (detected on mammography and/or palpation) in 16 patients. Patients were prone with their compressed mediolaterally between two plates in a circularly polarized RF coil. Lesion position was determined by reference to fiducial makers that corresponded to a grid of holes placed at 5 mm intervals in compression plate. FNA wasmore » performed with a 22G non-ferromagnetic needle. FNA was successful for 11 of 18 lesions (61%). Of the seven unsuccessful cases, there were four in which the lesions were too posteriorly placed to be accessed through the compression plate by the needle. Three cases were too anteriorly placed to be effectively immobilized and, although successfully localized, were insufficiently sampled by the FNA technique. MR-guided FNA is possible using a prototype breast localization device in a select group of patients. Current coil design limits its use in performing MR-guided FNA on the most anteriorly and posteriorly placed breast lesions. Unique requirements of FNA under MR guidance as compared to needle localization and biopsy have been identified. Modifications in localization hardware and cytology aspiration needles should overcome these restrictions. 15 refs., 3 figs.« less

  14. Basics of kidney biopsy: A nephrologist's perspective

    PubMed Central

    Agarwal, S. K.; Sethi, S.; Dinda, A. K.

    2013-01-01

    The introduction of the kidney biopsy is one of the major events in the history of nephrology. Primary indications of kidney biopsy are glomerular hematuria/proteinuria with or without renal dysfunction and unexplained renal failure. Kidney biopsy is usually performed in prone position but in certain situations, supine and lateral positions may be required. Biopsy needles have changed with times from Vim–Silverman needle to Tru-cut needle to spring-loaded automatic gun. The procedure has also changed from blind bedside kidney biopsy to ultrasound marking to real-time ultrasound guidance to rarely computerized tomography guidance and laparoscopic and open biopsy. In very specific situations, transjugular kidney biopsy may be required. Most of the centers do kidney biopsy on short 1-day admission, whereas some take it as an outdoor procedure. For critical interpretation of kidney biopsy, adequate sample and clinical information are mandatory. Tissue needs to be stained with multiple stains for delineation of various components of kidney tissue. Many consider that electron microscopy (EM) is a must for all kidney biopsies, but facilities for EM are limited even in big centers. Sophisticated tests such as immunohistochemistry and in-situ hybridization are useful adjuncts for definitive diagnosis in certain situations. PMID:23960337

  15. Augmented reality guidance system for peripheral nerve blocks

    NASA Astrophysics Data System (ADS)

    Wedlake, Chris; Moore, John; Rachinsky, Maxim; Bainbridge, Daniel; Wiles, Andrew D.; Peters, Terry M.

    2010-02-01

    Peripheral nerve block treatments are ubiquitous in hospitals and pain clinics worldwide. State of the art techniques use ultrasound (US) guidance and/or electrical stimulation to verify needle tip location. However, problems such as needle-US beam alignment, poor echogenicity of block needles and US beam thickness can make it difficult for the anesthetist to know the exact needle tip location. Inaccurate therapy delivery raises obvious safety and efficacy issues. We have developed and evaluated a needle guidance system that makes use of a magnetic tracking system (MTS) to provide an augmented reality (AR) guidance platform to accurately localize the needle tip as well as its projected trajectory. Five anesthetists and five novices performed simulated nerve block deliveries in a polyvinyl alcohol phantom to compare needle guidance under US alone to US placed in our AR environment. Our phantom study demonstrated a decrease in targeting attempts, decrease in contacting of critical structures, and an increase in accuracy of 0.68 mm compared to 1.34mm RMS in US guidance alone. Currently, the MTS uses 18 and 21 gauge hypodermic needles with a 5 degree of freedom sensor located at the needle tip. These needles can only be sterilized using an ethylene oxide process. In the interest of providing clinicians with a simple and efficient guidance system, we also evaluated attaching the sensor at the needle hub as a simple clip-on device. To do this, we simultaneously performed a needle bending study to assess the reliability of a hub-based sensor.

  16. The Second American Society of Regional Anesthesia and Pain Medicine Evidence-Based Medicine Assessment of Ultrasound-Guided Regional Anesthesia: Executive Summary.

    PubMed

    Neal, Joseph M; Brull, Richard; Horn, Jean-Louis; Liu, Spencer S; McCartney, Colin J L; Perlas, Anahi; Salinas, Francis V; Tsui, Ban Chi-Ho

    2016-01-01

    In 2009 and again in 2012, the American Society of Regional Anesthesia and Pain Medicine assembled an expert panel to assess the evidence basis for ultrasound guidance as a nerve localization tool for regional anesthesia. The 2012 panel reviewed evidence from the first advisory but focused primarily on new information that had emerged since 2009. A new section was added regarding the accuracy and reliability of ultrasound for determining needle-to-nerve proximity. Jadad scores are used to rank study quality. Grades of recommendations consistent with their level of evidence are provided. The panel offers recommendations based on synthesis and analysis of literature related to (1) the technical capabilities of ultrasound equipment and its operators, (2) comparison of ultrasound to other methods of nerve localization with regard to block characteristics, (3) comparison of block techniques where ultrasound is the sole nerve localization modality, and (4) major complications. Assessment of evidence strength and recommendations are made for upper- and lower-extremity, truncal, neuraxial, and pediatric blocks. Scientific evidence from the past 5 years has clarified and strengthened our understanding of ultrasound-guided regional anesthesia as a nerve localization tool. High-level evidence supports ultrasound guidance contributing to superior characteristics with selected blocks, although absolute differences with the comparator technique are often relatively small (especially for upper-extremity blocks). The clinical meaningfulness of these differences is likely of variable importance to individual practitioners. The use of ultrasound significantly reduces the risk of local anesthetic systemic toxicity as well as the incidence and intensity of hemidiaphragmatic paresis, but has no significant effect on the incidence of postoperative neurologic symptoms. WHAT'S NEW IN THIS UPDATE?: This evidence-based assessment of ultrasound-guided regional anesthesia reviews findings from our 2010 publication and focuses on new meta-analyses, randomized controlled trials, and large case series published since 2009. New to this exercise is an in-depth analysis of the accuracy and reliability of ultrasound guidance for identifying needle-to-nerve relationships. This version no longer addresses ultrasound for interventional pain medicine procedures, because the growth of that field demands separate consideration. Since our 2010 publication, new information has either supported or strengthened our original conclusions. There is no evidence that ultrasound is inferior to alternative nerve localization methods.

  17. Pancreatic Cystic Fluid Reference Set — EDRN Public Portal

    Cancer.gov

    The proposed reference set will be designed to evaluate biomarkers for the following applications aimed at determining whether a patient would benefit from surgical resection of their cystic lesion: 1.   Distinguish between pancreatic cysts that have high-malignant potential and cysts that have low or no malignant potential at time of endoscopic ultrasound evaluation. a.   By analysis of blood b.   By analysis of pancreatic cystic fluid 2.   Distinguish between cysts that have any malignant potential (high and low) and cysts that have no malignant potential (benign lesions) at time of endoscopic ultrasound evaluation. a.   By analysis of blood b.   By analysis of pancreatic cystic fluid 3.   Distinguish between a cyst that is mucinous (malignant potential) or non-mucinous (no malignant potential) at time of endoscopic ultrasound evaluation. a.   By analysis of blood b.   By analysis of pancreatic cystic fluid 4.   Distinguish between pancreatic cysts that have high-malignant potential and cysts that have low or no malignant potential at time of evaluation in surgery clinic. a.   By analysis of blood 5.   Distinguish between cysts that have any malignant potential (high and low) and cysts that have no malignant potential (benign lesions) at time of evaluation in surgery clinic. a.   By analysis of blood 6.   Distinguish between a cyst that is mucinous (malignant potential) or non-mucinous (no malignant potential) at time of evaluation in surgery clinic. a.   By analysis of blood If successful in meeting these afore-mentioned objectives, these results can then be used in the development of future studies at identifying the need for additional evaluation (i.e., endoscopic ultrasound with fine needle aspiration) of an incidental cyst

  18. Comparison of Sample Adequacy and Diagnostic Yield of 19- and 22-G EBUS-TBNA Needles.

    PubMed

    Chaddha, Udit; Ronaghi, Reza; Elatre, Waafa; Chang, Ching-Fei; Mahdavi, Ramyar

    2018-05-16

    The 2016 CHEST consensus guidelines recommend use of either 21- or 22-G needles for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). We decided to prospectively compare sample adequacy and diagnostic yield of the 19-G with the 22-G EBUS needle, hypothesizing that a larger gauge difference might magnify the differences between 2 needle sizes. Twenty-seven patients undergoing EBUS-TBNA at our institution were evaluated. All cases were performed by a single operator formally trained in interventional pulmonology. Both Olympus 19- and 22-G needles were used at each lymph node station in an alternating manner. Rapid on-site cytology evaluation was used and a separate cell block was prepared for each needle at each station. Fifty-six lymph nodes were analyzed. Diagnoses included cancer (36%, including 1 lymphoma), reactive lymphoid tissue (53%), and sarcoidosis (11%). One hundred sixty-two and 163 passes were made with the 22- and 19-G needle, respectively. Sample adequacy was 73% and 46% with the 22 and 19-G needle, respectively (P<0.001). Significantly fewer passes were bloody with the 22-G compared with the 19-G needle (19% vs. 59%; P<0.001). Diagnostic yield was not different between the 22- and 19-G needles (95% vs. 93%; P=0.62). In addition to no difference in diagnostic yield, the 19-G needle yielded samples that were frequently less adequate and more often bloody compared with the 22-G needle. Despite the larger caliber lumen, we conclude that the 19-G needle does not confer a diagnostic advantage.

  19. Preoperative ultrasound staging of the axilla make's peroperative examination of the sentinel node redundant in breast cancer: saving tissue, time and money.

    PubMed

    Van Berckelaer, Christophe; Huizing, Manon; Van Goethem, Mireille; Vervaecke, Andrew; Papadimitriou, Konstantinos; Verslegers, Inge; Trinh, Bich X; Van Dam, Peter; Altintas, Sevilay; Van den Wyngaert, Tim; Huyghe, Ivan; Siozopoulou, Vasiliki; Tjalma, Wiebren A A

    2016-11-01

    To evaluate the role of preoperative axillary staging with ultrasound (US) and fine needle aspiration cytology (FNAC). Can we avoid intraoperative sentinel lymph node (SLN) examination, with an acceptable revision rate by preoperative staging? This study is based on the retrospective data of 336 patients that underwent US evaluation of the axilla as part of their staging. A FNAC biopsy was performed when abnormal lymph nodes were visualized. Patients with normal appearing nodes on US or a benign diagnostic biopsy had removal of the SLNs without intraoperative pathological examination. We calculated the sensitivity, specificity and accuracy of US/FNAC in predicting the necessity of an axillary lymphadenectomy. Subsequently we looked at the total cost and the operating time of 3 models. Model A is our study protocol. Model B is a theoretical protocol based on the findings of the Z0011 trial with only clinical preoperative staging and in Model C preoperative staging and intraoperative pathological examination were both theoretically done. sentinel node, staging, ultrasound, preoperative axillary staging, FNAC, axilla RESULTS: The sensitivity, specificity and accuracy are respectively 0.75 (0.66-0.82), 1.00 (0.99-1.00) and 0.92 (0.88-0.94). Only 26 out of 317 (8.2%) patients that successfully underwent staging needed a revision. The total cost of Model A was 1.58% cheaper than Model C and resulted in a decrease in operation time by 9,46%. The benefits compared with Model B were much smaller. Preoperative US/FNAC staging of the axillary lymph nodes can avoid intraoperative examination of the sentinel node with an acceptable revision rate. It saves tissue, reduces operating time and decreases healthcare costs in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Thyroid nodule classification using ultrasound elastography via linear discriminant analysis.

    PubMed

    Luo, Si; Kim, Eung-Hun; Dighe, Manjiri; Kim, Yongmin

    2011-05-01

    The non-surgical diagnosis of thyroid nodules is currently made via a fine needle aspiration (FNA) biopsy. It is estimated that somewhere between 250,000 and 300,000 thyroid FNA biopsies are performed in the United States annually. However, a large percentage (approximately 70%) of these biopsies turn out to be benign. Since the aggressive FNA management of thyroid nodules is costly, quantitative risk assessment and stratification of a nodule's malignancy is of value in triage and more appropriate healthcare resources utilization. In this paper, we introduce a new method for classifying the thyroid nodules based on the ultrasound (US) elastography features. Unlike approaches to assess the stiffness of a thyroid nodule by visually inspecting the pseudo-color pattern in the strain image, we use a classification algorithm to stratify the nodule by using the power spectrum of strain rate waveform extracted from the US elastography image sequence. Pulsation from the carotid artery was used to compress the thyroid nodules. Ultrasound data previously acquired from 98 thyroid nodules were used in this retrospective study to evaluate our classification algorithm. A classifier was developed based on the linear discriminant analysis (LDA) and used to differentiate the thyroid nodules into two types: (I) no FNA (observation-only) and (II) FNA. Using our method, 62 nodules were classified as type I, all of which were benign, while 36 nodules were classified as Type-II, 16 malignant and 20 benign, resulting in a sensitivity of 100% and specificity of 75.6% in detecting malignant thyroid nodules. This indicates that our triage method based on US elastography has the potential to substantially reduce the number of FNA biopsies (63.3%) by detecting benign nodules and managing them via follow-up observations rather than an FNA biopsy. Published by Elsevier B.V.

Top