Sample records for ultrasound fine-needle aspiration

  1. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  2. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  3. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  4. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses

    PubMed Central

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-01-01

    Objective: Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. Patients and Methods: A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). Results: EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). Conclusion: EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate. PMID:24949394

  5. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    PubMed Central

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  6. Endoscopic ultrasound-guided fine-needle aspiration needles: which one and in what situation?

    PubMed

    Karadsheh, Zeid; Al-Haddad, Mohammad

    2014-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is increasingly used as a diagnostic and therapeutic tool for pancreatic and other gastrointestinal disorders. Several factors affect the outcome of EUS-FNA, one of which is needle size. The decision to use a specific needle depends on factors including location, consistency, and type of the lesion; presence of onsite cytopathologist; and need for additional tissue procurement for histology. This review provides a balanced perspective on the use of different needle sizes available, highlighting the differences among them and potential niche applications of each to maximize diagnostic yield of EUS-FNA. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  8. Isolated splenic tuberculosis diagnosed by endoscopic ultrasound-guided fine needle aspiration.

    PubMed

    Nasa, Mukesh; Choudhary, Narendra S; Guleria, Mridula; Puri, Rajesh

    2017-04-01

    Our patient was a 48-year-old female, who presented with history of persistent low-grade fever and weight loss. The CT scan of the abdomen revealed multiple hypodense lesions in spleen. No primary focus of infection was detected in any other organs. Endoscopic ultrasound-guided fine needle aspiration of splenic lesion revealed granulomatous inflammation. The patient was started on anti-tuberculous therapy. There is a diagnostic possibility of splenic tuberculosis even in immunocompetent individuals and we chose a combination anti-tuberculous therapy as the first line treatment with consideration of splenectomy depending on the response. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  9. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    PubMed

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  10. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  11. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    PubMed Central

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  12. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  13. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases.

    PubMed

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-12-14

    To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients ( P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group ( P < 0.05). Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration.

  14. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases

    PubMed Central

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-01-01

    AIM To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. METHODS Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. RESULTS There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients (P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group (P < 0.05). CONCLUSION Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration. PMID:28028373

  15. Endoscopic Ultrasound-Guided Fine Needle Aspiration: From the Past to the Future

    PubMed Central

    Costache, Mădălin-Ionuț; Iordache, Sevastița; Karstensen, John Gásdal; Săftoiu, Adrian; Vilmann, Peter

    2013-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a technique which allows the study of cells obtained through aspiration in different locations near the gastrointestinal tract. EUS-FNA is used to acquire tissue from mucosal/submucosal tumors, as well as peri-intestinal structures including lymph nodes, pancreas, adrenal gland, gallbladder, bile duct, liver, kidney, lung, etc. The pancreas and lymph nodes are still the most common organs targeted in EUS-FNA. The overall accuracy of EUS is superior to computed tomography scan and magnetic resonance imaging for detecting pancreatic lesions. In most cases it is possible to avoid unnecessary surgical interventions in advanced pancreatic cancer, and EUS is considered the preferred method for loco-regional staging of pancreatic cancer. FNA improved the sensitivity and specificity compared to EUS imaging alone in detection of malignant lymph nodes. The negative predictive value of EUS-FNA is relatively low. The presence of a cytopathologist during EUS-FNA improves the diagnostic yield, decreasing unsatisfactory samples or need for additional passes, and consequently the procedural time. The size of the needle is another factor that could modify the diagnostic accuracy of EUS-FNA. Even though the EUS-FNA technique started in early nineteen's, there are many remarkable progresses culminating nowadays with the discovery and performance of needle-based confocal laser endomicroscopy. Last, but not least, identification and quantification of potential molecular markers for pancreatic cancer on cellular samples obtained by EUS-FNA could be a promising approach for the diagnosis of solid pancreatic masses. PMID:24949369

  16. Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis

    PubMed Central

    Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao

    2013-01-01

    AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631

  17. Rapid diagnosis of liver cancer by ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Huber, K; Heuhold, N

    1987-01-01

    Because of the relatively favorable prognosis to the patient with early detected hepatocarcinoma followed by surgical treatment if resection is possible, it is important to differentiate quickly between primary and secondary liver cancer. Ultrasound-guided percutaneous fine needle aspiration biopsy (US-FNAB) was used as a first diagnostic measure in patients with sonographic evidence of liver tumors. Biopsies were done under sonographic control and antiseptic conditions from the center and the border zone of solid tumors of the liver, and the aspirated cell material was air dried on glass slides and Giemsa stained. The cytologic diagnosis was proved by clinical course and in most cases by surgical or autoptic histology. Cytologic evaluation lead in 15 cases to the diagnosis of definitive or suspicious malignant liver disease; the sensitivity was 93% and the specificity was 87%. One case classified as suspicious for malignancy by cytologic examination could be identified as cirrhotic nodule by further investigations. In none of the patients did we find complications from the biopsy procedure. From these data it is concluded that US-FNAB can serve as a rapid, inexpensive, safe, and highly accurate first diagnostic step in patients with solid lesions of the liver.

  18. Guided percutaneous fine-needle aspiration biopsy of the liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, C.S.; McLoughlin, M.J.; Tao, L.C.

    1981-04-01

    Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less

  19. Ultrasonography and fine needle aspirate cytology of the mesenteric lymph node in normal domestic ferrets (Mustela putorius furo).

    PubMed

    Paul-Murphy, J; O'Brien, R T; Spaeth, A; Sullivan, L; Dubielzig, R R

    1999-01-01

    The large mesenteric lymph node of 28 normal ferrets was imaged with ultrasound. The large node, located in the mid-abdomen at the root of the mesentery, was round to ovoid and uniformly hyperechoic. Mean ultrasonographic dimensions of the lymph node were 12.6 +/- 2.6 mm by 7.6 +/- 2.0 mm. Fine needle aspirates of 20 lymph nodes were obtained either using ultrasound guided free-hand techniques or at necropsy. The cytological descriptions were compared to histological descriptions of 13 lymph node core biopsies obtained during laparotomy or necropsy as well as 10 peripheral blood smear differentials. The large mesenteric lymph node of ferrets could be easily imaged and measured by ultrasound and evaluated by fine needle aspirate cytology. Normal lymph node cytology may include an eosinophilic infiltrate.

  20. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    PubMed Central

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  1. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    NASA Astrophysics Data System (ADS)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  2. ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION IN THE DIAGNOSIS OF ADRENAL METASTASIS IN A HIGH-RISK POPULATION.

    PubMed

    Zhang, Catherine D; Erickson, Dana; Levy, Michael J; Gleeson, Ferga C; Salomao, Diva R; Delivanis, Danae A; Bancos, Irina

    2017-12-01

    While the left adrenal gland is readily accessible via endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), data regarding the utility of EUS-FNA in the diagnosis of adrenal lesions remain limited. We aimed to ( 1) describe the clinical context, adverse event rate, and diagnostic performance of EUS-FNA, and ( 2) compare the safety profile and diagnostic accuracy of EUS-FNA with percutaneous adrenal biopsy. Single-center, retrospective cohort study. Medical records of patients who underwent adrenal EUS-FNA from 2005-2016 were reviewed. Biopsy outcomes were evaluated using a predefined reference standard. Results were compared to patients who underwent percutaneous biopsy (n = 419; 1994-2014) at the same institution. A total of 121 patients underwent EUS-FNA of 122 adrenal lesions (left [n = 121]; right [n = 1]; mean lesion size, 1.8 cm). Cytology was positive for malignancy in 35 (29%), suspicious for malignancy in 1 (1%), atypical in 1 (1%), negative for malignancy in 81 (66%), and nondiagnostic in 4 (3%). No adverse events were reported. EUS-FNA diagnosed metastasis with a sensitivity of 100%, specificity of 97.4%, positive predictive value of 91.7%, and negative predictive value of 100%. When compared to percutaneous biopsy, lesion size (1.8 cm vs. 3.7 cm; P<.001) and biopsy site (99% vs. 62% left adrenal; P<.001) were significantly different. EUS-FNA adverse event rate was lower than percutaneous biopsy (0% vs. 4%; P = .024), but nondiagnostic rates were similar (3.3% vs. 4.8%; P = .48). EUS-FNA is a sensitive technique to sample adrenal lesions in patients at high risk for adrenal metastasis with fewer adverse events compared to percutaneous biopsy. CI = confidence interval CT = computed tomography EUS-FNA = endoscopic ultrasound-guided fine-needle aspiration NPV = negative predictive value PPV = positive predictive value TUS = transabdominal ultra-sound.

  3. Rare pancreatic neoplasms: the utility of endoscopic ultrasound-guided fine-needle aspiration-a large single center study.

    PubMed

    Imaoka, Hiroshi; Yamao, Kenji; Bhatia, Vikram; Shimizu, Yasuhiro; Yatabe, Yasushi; Koshikawa, Takashi; Kinoshita, Yoshikazu

    2009-01-01

    Tumors other than ductal adenocarcinomas constitute 10%-15% of all pancreatic tumors. We describe the performance and pitfalls of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosis of these rare pancreatic tumors and their characteristic cytopathological features. The records of 455 pancreatic fine-needle aspiration procedures done between March 1997 and August 2006 at Aichi Cancer Center, Nagoya, Japan, were reviewed. Besides cytology, aspirated material was routinely submitted in formalin for cell-block analysis. The reference standard for final diagnosis was surgical pathology from resected specimens. Twenty-eight rare (nonductal adenocarcinomas) pancreatic tumors were identified. Overall, EUS-FNA with the results of cytology, cell-block processing, and immunohistochemistry could correctly diagnose the type of neoplasm in 19 (67.9%) cases. EUS-FNA could distinguish benign from malignant rare tumors with a sensitivity of 69.2%, a specificity of 100%, positive predictive value of 100%, negative predictive value of 79.0%, and accuracy of 85.7%. None of three malignant pancreatic endocrine neoplasms could be diagnosed as malignant. An adequate core tissue sample could be obtained in 21 cases (75.0%) and provide a histopathological diagnosis in 19 (67.9%) cases. EUS-FNA could change the presumptive diagnosis in 11 (39.3%) cases. Specific immunochemical studies were useful adjuncts to the diagnosis. No major or minor complication was noted in any patient. Pancreatic neoplasms other than ductal adenocarcinomas have diverse imaging and histopathological features. EUS-FNA is accurate and safe for their identification.

  4. Toxoplasma lymphadenitis diagnosed by fine-needle aspiration cytology: a rare finding.

    PubMed

    Hosokawa, S; Kusama, Y; Ono, T; Mineta, H

    2014-06-01

    There are only very few reports of cervical toxoplasma lymphadenitis being diagnosed exclusively via fine-needle aspiration cytology (with serology). We describe a case of toxoplasma lymphadenitis that was successfully diagnosed by fine-needle aspiration cytology. The case involved a male patient who was immunocompromised as a result of recurrent acute myelogenous leukaemia with cervical lymphadenopathy. The biopsy showed typical features of a well-defined pseudocyst containing Toxoplasma gondii tachyzoites. Toxoplasma lymphadenitis is a common cause of lymph node enlargement. Fine-needle aspiration cytology is a useful method for diagnosing and differentiating toxoplasma lymphadenitis from more serious causes of lymphadenopathy, such as metastatic lymphadenopathy or lymphoma.

  5. Extramedullary plasmacytoma. Fine needle aspiration findings.

    PubMed

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  6. Cell-block procedure in endoscopic ultrasound-guided-fine-needle-aspiration of gastrointestinal solid neoplastic lesions

    PubMed Central

    Ieni, Antonio; Barresi, Valeria; Todaro, Paolo; Caruso, Rosario Alberto; Tuccari, Giovanni

    2015-01-01

    In the present review we have analyzed the clinical applications of endoscopic ultrasound-guided-fine-needle-aspiration (EUS-FNA) and the methodological aspects obtained by cell-block procedure (CBP) in the diagnostic approach to the gastrointestinal neoplastic pathology. CBP showed numerous advantages in comparison to the cytologic routine smears; in particular, better preservation of cell architecture, achievement of routine haematoxylin-eosin staining equivalent to histological slides and possibility to perform immunohistochemistry or molecular analyses represented the most evident reasons to choose this method. Moreover, by this approach, the differential diagnosis of solid gastrointestinal neoplasias may be more easily achieved and the background of contaminant non-neoplastic gastrointestinal avoided. Finally, biological samples collected by EUS-FNA CBP-assisted should be investigated in order to identify and quantify further potential molecular markers. PMID:26322154

  7. Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses

    PubMed Central

    Voss, M; Hammel, P; Molas, G; Palazzo, L; Dancour, A; O'Toole, D; Terris, B; Degott, C; Bernades, P; Ruszniewski, P

    2000-01-01

    AIM—To assess the feasibility and diagnostic accuracy of endoscopic ultrasound guided fine needle biopsy (EUS-FNAB) in patients with solid pancreatic masses.
METHODS—Ninety nine consecutive patients with pancreatic masses were studied. Histological findings obtained by EUS-FNAB were compared with the final diagnosis assessed by surgery, biopsy of other tumour site or at postmortem examination, or by using a combination of clinical course, imaging features, and tumour markers.
RESULTS—EUS-FNAB was feasible in 90 patients (adenocarcinomas, n = 59; neuroendocrine tumours, n = 15; various neoplasms, n = 6; pancreatitis, n = 10), and analysable material was obtained in 73. Tumour size (⩾ or < 25 mm in diameter) did not influence the ability to obtain informative biopsy samples. Diagnostic accuracy was 74.4% (adenocarcinomas, 81.4%; neuroendocrine tumours, 46.7%; other lesions, 75%; p<0.02). Overall, the diagnostic yield in all 99 patients was 68%. Successful biopsies were performed in six patients with portal hypertension. Minor complications (moderate bleeding or pain) occurred in 5% of cases.
CONCLUSIONS—EUS-FNAB is a useful and safe method for the investigation of pancreatic masses, with a high feasibility rate even when lesions are small. Overall diagnostic accuracy of EUS-FNAB seems to depend on the tumour type.


Keywords: pancreas; tumour; endoscopic ultrasound; fine needle aspiration biopsy PMID:10644320

  8. Endobronchial ultrasound-guided transbronchial needle aspiration of thyroid: Report of two cases and systematic review of literature

    PubMed Central

    Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep

    2016-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005

  9. Fine needle aspiration cytology.

    PubMed Central

    Lever, J V; Trott, P A; Webb, A J

    1985-01-01

    Fine needle aspiration cytology is an inexpensive, atraumatic technique for the diagnosis of disease sites. This paper describes the technique and illustrates how it may be applied to the management of tumours throughout the body. The limitations of the method, the dangers of false positive reports, and the inevitability of false negative diagnoses are emphasised. In a clinical context the method has much to offer by saving patients from inappropriate operations and investigations and allowing surgeons to plan quickly and more rationally. It is an economically valuable technique and deserves greater recognition. Images PMID:2578481

  10. Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods

    PubMed Central

    Tadic, Mario; Stoos-Veic, Tajana; Kusec, Rajko

    2014-01-01

    The role of endoscopic ultrasound (EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration (FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA (EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition (needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy. PMID:25339816

  11. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    PubMed

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  12. Fine-needle aspiration by vacuum tubes.

    PubMed

    Holmquist, N D

    1989-07-01

    Fine-needle aspiration of subcutaneous masses, accepted in many parts of Europe and the Americas as a routine diagnostic technique, employs a syringe holder to facilitate the creation of a vacuum to withdraw cells. This investigation demonstrates that a vacuum tube used in venipuncture can be used to supply the negative pressure to suck cells into the needle. This apparatus is more readily available than a syringe holder in hospitals and clinics, and particularly provides the operator with a more dexterous approach to the mass because the fingers holding the needle can be much closer to the mass being immobilized by the other hand.

  13. Ultrasound-guided fine-needle aspiration biopsy of clinically suspicious thyroid nodules with an automatic aspirator: a novel technique.

    PubMed

    Nagarajah, James; Sheu-Grabellus, Sien-Yi; Farahati, Jamshid; Kamruddin, Kamer A; Bockisch, Andreas; Schmid, Kurt Werner; Görges, Rainer

    2012-07-01

    Fine-needle aspiration biopsy (FNAB) is a simple technique for the investigation of suspicious thyroid nodules. However, low success rates are reported in the literature. The aim of this prospective study was to compare the clinical performance and impact of an automatic aspirator, referred to here as Aspirator 3, to those of the manual technique for the FNAB of clinically suspicious thyroid nodules. One hundred nine consecutive patients with 121 clinically suspicious thyroid nodules underwent a biopsy twice of the same site with the clinically approved Aspirator 3 and with the manual technique. The number of follicular cell formations and the total number of follicular cells in the aspirate were counted using the ThinPrep® method. With the Aspirator 3, the total number and the mean number of extracted cell formations were significantly higher than the values achieved with the manual technique (total: 3222 vs. 1951, p=0.02; mean: 27 vs. 16). The total number of cells that were biopsied was also higher when the Aspirator 3 was utilized (47,480 vs. 23,080, p=0.005). Overall, the Aspirator 3 was superior in 65 biopsies, and the manual technique was superior in 39 biopsies. In terms of cell formations and the total number of cells aspirated, the Aspirator 3 was superior to the manual technique. Further, the Aspirator 3 was more convenient to use and had a greater precision in needle guidance.

  14. Primary cutaneous aspergillosis from Tamilnadu diagnosed by fine needle aspiration cytology

    PubMed Central

    Venugopal, Taralakshmi V.; Venugopal, Pankajalakshmi V.

    2012-01-01

    Aspergillus are ubiquitous and more than 30 species have been reported to be involved in human infection. Most of the cases occur in immunocompromised patients and are disseminated in the blood. Primary cutaneous aspergillosis in immunocompetent hosts is rare. We report a unique case of primary cutaneous aspergillosis in an immunocompetent patient diagnosed by fine needle aspiration cytology. The characteristic ascocarp and ascospores of Aspergillus species were found in the aspirate and Aspergillus glaucus was isolated in pure culture. The case is presented to increase the awareness of the usefulness of fine needle aspiration cytology for diagnosing fungal infections. PMID:24371752

  15. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no

  16. The cost-effectiveness of iodine 131 scintigraphy, ultrasonography, and fine-needle aspiration biopsy in the initial diagnosis of solitary thyroid nodules.

    PubMed

    Khalid, Ayesha N; Hollenbeak, Christopher S; Quraishi, Sadeq A; Fan, Chris Y; Stack, Brendan C

    2006-03-01

    To compare the cost-effectiveness of fine-needle aspiration biopsy, iodine 131 scintigraphy, and ultrasonography for the initial diagnostic workup of a solitary palpable thyroid nodule. A deterministic cost-effectiveness analysis was conducted using a decision tree to model the diagnostic strategies. A single, mid-Atlantic academic medical center. Expected costs, expected number of cases correctly diagnosed, and incremental cost per additional case correctly diagnosed. Relative to the routine use of fine-needle aspiration biopsy, the incremental cost per case correctly diagnosed is 24,554 dollars for the iodine 131 scintigraphy strategy and 1212 dollars for the ultrasound strategy. A diagnostic strategy using initial fine-needle aspiration biopsy for palpable thyroid nodules was found to be cost-effective compared with the other approaches as long as a payor's willingness to pay for an additional correct diagnosis is less than 1212 dollars. Prospective studies are needed to validate these finding in clinical practice.

  17. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    PubMed

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  18. Diagnosis of metastatic pancreatic mesenchymal tumors by endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Varghese, Linda; Ngae, Min Yi; Wilson, Andrew P; Crowder, Clinton D; Gulbahce, H Evin; Pambuccian, Stefan E

    2009-11-01

    Involvement of the pancreas by metastatic sarcoma is rare, and can prove challenging to differentiate from sarcomatoid carcinomas which occur more commonly. The endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) technique has been successfully used for the diagnosis of pancreatic carcinomas whether primary or metastatic, and is now considered the most effective noninvasive method for the identification of pancreatic metastases. However, to date very few reports detail the diagnosis of mesenchymal neoplasms by EUS-FNA. Herein, we report a series of four patients who underwent EUS-FNA of the pancreas, where the diagnosis of metastatic sarcoma was made based on morphology and ancillary studies. The cases include metastases of leiomyosarcoma, liposarcoma, alveolar rhabdomyosarcoma, and solitary fibrous tumor. The history of a primary sarcoma of the chest wall, mediastinum, and respectively lower extremity was known for the first three of these patients while in the case of the solitary fibrous tumor a remote history of a paraspinal "hemangiopericytoma" was only elicited after the EUS-FNA diagnosis was made. We conclude that EUS-FNA is efficient and accurate in providing a diagnosis of sarcoma, even in patients without a known primary sarcoma, thus allowing institution of therapy without additional biopsies.

  19. Regional lymph node staging in breast cancer: the increasing role of imaging and ultrasound-guided axillary lymph node fine needle aspiration.

    PubMed

    Mainiero, Martha B

    2010-09-01

    The status of axillary lymph nodes is a key prognostic indicator in patients with breast cancer and helps guide patient management. Sentinel lymph node biopsy is increasingly being used as a less morbid alternative to axillary lymph node dissection. However, when sentinel lymph node biopsy is positive, axillary dissection is typically performed for complete staging and local control. Axillary ultrasound and ultrasound-guided fine needle aspiration (USFNA) are useful for detecting axillary nodal metastasis preoperatively and can spare patients sentinel node biopsy, because those with positive cytology on USFNA can proceed directly to axillary dissection or neoadjuvant chemotherapy. Internal mammary nodes are not routinely evaluated, but when the appearance of these nodes is abnormal on imaging, further treatment or metastatic evaluation may be necessary. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Endoscopic ultrasound guided brush/fine-needle aspiration cytology: A 15-month study.

    PubMed

    Tummidi, Santosh; Kothari, Kanchan; Sathe, Pragati; Agnihotri, Mona; Fernandes, Gwendolyn; Naik, Leena; Jain, Aleena; Chaturvedi, Rachana

    2018-06-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has become increasingly popular for the diagnosis and staging of gastrointestinal diseases and peri-gastrointestinal lesions. The application of FNA/Brush has dramatically expanded the clinical utility of EUS. To evaluate the diagnostic accuracy, study the spectrum of lesions encountered in EUS-FNAC/brush cytology of gastrointestinal and peri-gastrointestinal lesions. Total of 124 patients during the period from August 2015 to November 2016 was included in the study. Routine staining was done. A total of 124 cases were studied with 86% (107 cases) being satisfactory for evaluation. M:F ratio was 1:1.03, mean age of 50.5 years. The most common site was common bile duct (CBD) (37%) followed by lymph node (21%), pancreas (17.7%), esophagus (17%), stomach (3.5%), liver (1.8%), gallbladder (1%), and spleen (1%). In total, 53.4% lesions were benign, in 6.5% atypical cells were seen, 12.1% were suspicious for malignancy, and 28% cases were positive for malignancy. Follow-up was available in 102 cases with cyto-histopathological concordance rate of 90%. EUS-FNA/Brush is a reliable, sensitive, specific and minimally invasive way to establish a diagnosis. It can be utilized as a pre-operative procedure for the management of many intra-abdominal lesions and prevent unnecessary invasive procedures. © 2018 Wiley Periodicals, Inc.

  1. Impact of endoscopic ultrasound-guided fine-needle aspiration in prospective liver transplant recipients with hepatocellular carcinoma and lymphadenopathy.

    PubMed

    Choudhary, Narendra S; Puri, Rajesh; Saigal, Sanjiv; Bhangui, Prashant; Saraf, Neeraj; Shah, Vinit; Nasa, Mukesh; Sarin, Haimanti; Guleria, Mridula; Sud, Randhir; Soin, Arvinder S

    2016-11-01

    Diagnosis of metastatic disease is important in patients with cirrhosis and hepatocellular carcinoma (HCC) to prevent futile liver transplantation. Some of these patients have metastatic lymphadenopathy; however, it is difficult to perform percutaneous fine-needle aspiration due to presence of collateral and anatomic location. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) of lymph nodes offers several advantages like real-time vision, proximity to target, and avoidance of collaterals. The aim of this study was to look for metastatic lymphadenopathy by EUS-guided FNA (EUS-FNA) in prospective liver transplant recipients with HCC. A prospective study was conducted from January 2013 to January 2016 at a tertiary care center. All prospective liver transplant recipients with HCC had PET-CT and bone scan to look for metastatic disease. EUS-FNA was done in patients with abdominal or mediastinal lymphadenopathy and no evidence of extrahepatic disease. Data is shown as median (25-75 interquartile range). EUS-guided FNA was done for 50 patients (42 abdominal and 8 mediastinal lymph nodes), age 57 (53-62) years, Child-Turcotte-Pugh 7 (6-9), and model for end-stage liver disease 10 (7-16). FNA material was adequate in 92% patients, metastasis in 15 (30%), granulomatous lymphadenopathy in 4 (8%), and reactive change in 27 patients (54%). The material was inadequate for diagnosis in 4 (8%) patients. Thus, EUS-guided FNA precluded transplantation in 30% of patients with lymphadenopathy, and 4 (8%) patients received anti-tubercular therapy before liver transplantation. In patients with HCC and lymphadenopathy, EUS-guided FNA detected metastatic disease and precluded liver transplantation in approximately one third of patients.

  2. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  3. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2018-06-01

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  4. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    PubMed

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  5. Nonpalpable breast tumors: diagnosis with stereotaxic localization and fine-needle aspiration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowlatshahi, K.; Gent, H.J.; Schmidt, R.

    1989-02-01

    Modern mammography is the most effective means of detecting nonpalpable breast cancers, but correct diagnosis for malignancy is made in only 20%-30% of the cases. The conventional method of lesion localization usually results in approximate placement of the hookwire in the breast. The authors report the results of stereotaxic localization, combined with fine-needle aspiration and cytologic study, performed in 528 cases. Clinically occult breast lesions were localized precisely (within 2 mm 96% of the time), sampled by means of a 23-gauge needle, and marked with either methylene blue or a hookwire for subsequent open excisional biopsy. The results indicate amore » sensitivity of 95%, specificity of 91%, and accuracy of 92% for the fine-needle aspiration procedure. This technique offers a significantly improved preoperative method of diagnosing small breast lesions with minimal pain, no complications, reduced cost, and no disfigurement or scar interfering with subsequent mammographic follow-up.« less

  6. Endobronchial ultrasound-guided transbronchial needle aspiration of pulmonary artery tumors: A systematic review (with video).

    PubMed

    Harris, Kassem; Modi, Kush; Kumar, Abhishek; Dhillon, Samjot Singh

    2015-01-01

    Convex probe endobronchial ultrasound (CP-EBUS) was originally introduced as a diagnostic and staging tool for lung cancer and subsequently utilized for diagnosis of other malignant and benign mediastinal diseases such as melanoma, lymphoma, and sarcoidosis. More recently, CP-EBUS has been successfully used for the visualization and diagnosis of pulmonary emboli and other vascular lesions including primary and metastatic pulmonary artery (PA) tumors. In this review, we will underline the role of EBUS-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of pulmonary arterial tumors such as sarcomas and tumor emboli. We will concisely discuss the clinical applications of EBUS-TBNA and the types of pulmonary arterial tumors and their different diagnostic modalities. We searched the Cochrane Library and PubMed from 2004 to 2014 to provide the most comprehensive review. Only 10 cases of EBUS-TBNA for intravascular lesions were identified in the literature. Although many cases of EBUS and EUS-guided transvascular tumor biopsies were described in the literature, there were no reported cases of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for intravascular tumor biopsies. Except for one paper, all cases were published as case reports.

  7. Stereotaxic fine-needle aspiration of low-suspicion, nonpalpable breast nodules: valid alternative to follow-up mammography.

    PubMed

    Franquet, T; Cozcolluela, R; De Miguel, C

    1992-06-01

    Seventy "low-suspicion," nonpalpable solid breast nodules were evaluated with stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography. Sonography was performed in all cases to determine the solid nature of the nodules. Eight cysts were incorrectly classified with sonography, corresponding to atypical cysts; in such cases, however, stereotaxic fine-needle aspiration not only enabled the diagnosis, but was therapeutic as well. Fifty-eight of 70 breast aspirates (83%) yielded adequate cellular material for cytologic interpretation. A specific cytologic diagnosis was made in 52 cases (51 benign, one malignant). Insufficient cytologic material was obtained in 12 cases (17%). These results should help establish the validity of stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography in patients with low-suspicion, solid breast nodules, reducing radiation exposure, patient anxiety, unnecessary biopsies, and costs.

  8. Endoscopic Ultrasound (EUS) Guided Fine Needle Aspiration: A New Modality to Diagnose Peritoneal Tuberculosis in Presence of Decompensated Cirrhosis-A Case Series and Review of Literature.

    PubMed

    Daswani, Ravi; Kumar, Ashish; Singla, Vikas; Kaur, Gagandeep; Sharma, Praveen; Bansal, Naresh; Arora, Anil

    2018-06-01

    The gold-standard for diagnosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the non-specific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal TB. To assess the role of EUS-FNA in the diagnosis of peritoneal tuberculosis in patients with decompensated cirrhosis. Consecutive patients with peritoneal thickening, ascites and decompensated cirrhosis underwent EUS-FNA from the thickened omentum. Presence of granuloma or demonstration of acid fast bacilli was diagnostic of peritoneal tuberculosis. A total of 5 patients with CLD underwent EUS-FNA from omentum. FNA cytology revealed granuloma with multinucleated cells in all patients (100%) and AFB stain was positive in 2 of them (40%). We hereby report the use of EUS guided fine needle aspiration (FNA) of peritoneum as a newer, safe and unexplored technique for diagnosis of peritoneal TB.

  9. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy.

    PubMed

    Naqvi, Hanna; Edhi, Muhammad Muzzammil; Aslam, Hafiz Muhammad; Faridi, Naveen

    2013-02-12

    Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis.

  10. Thyroid Swelling and Thyroiditis in the Setting of Recent hCG Injections and Fine Needle Aspiration

    PubMed Central

    Lamos, Elizabeth M.; Munir, Kashif M.

    2016-01-01

    A 60-year-old woman presented with a neck mass and underwent fine needle aspiration of a left thyroid nodule. During this time, she had been injected with hCG for weight loss. Soon after, she developed rapid diffuse thyroid growth with pain. She was ultimately diagnosed with thyrotoxicosis due to postaspiration subacute thyroiditis and subsequently became hypothyroid. This condition is rare in the nonpregnant state in noncystic nodules with a smaller needle gauge approach. The incidence of thyroid nodule discovery and evaluation is increasing. As more procedures are undertaken, understanding of potential complications is important. This case highlights potential complications of thyroid fine needle aspiration including diffuse thyroid swelling and thyroiditis. The role of hCG injections is speculated to have potentially stimulated thyroid follicular epithelium via cross-reactivity with the TSH receptor and contributed to the acute inflammatory response after fine needle aspiration. PMID:26942022

  11. To fine needle aspiration or not? An endosonographer's approach to pancreatic cystic lesions

    PubMed Central

    But, David Yiu-Kuen; Poley, Jan-Werner

    2014-01-01

    Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is an established diagnostic tool in the management of pancreatic cystic lesions (PCLs). Due to the proximity to the target lesion, the fine diagnostic needle travels through only minimal normal tissues. The risks of bleeding, pancreatitis and infection are small. Valuable diagnostic morphological information can be obtained by EUS before the use of FNA. The additional cytopathologic and cyst fluid analysis for the conventional markers such as amylase, carcinoembryonic antigen (CEA) and CA19.9 improves the diagnostic capability. Pancreatic cyst fluid CEA concentration of 192 ng/mL is generally the most agreed cutoff to differentiate mucinous from non-mucinous lesion. A fluid amylase level of <250 IU/L excludes the diagnosis of pseudocyst. Technical tips of EUS-FNA and the limitations of the procedure are discussed. Promising technique and FNA needle modifications have been described to improve the diagnostic yield at the cytopathologic analysis. The use of novel cyst fluid proteomics and deoxyribonucleic acid-based biomarkers of the PCLs are reviewed. Although it is considered a safe procedure, EUS-FNA is not a routine in every patient. Recommendations of the role of EUS-FNA at various common clinical scenarios are discussed. PMID:24955337

  12. Diagnosis of clinical bovine mastitis by fine needle aspiration followed by staining and scanning electron microscopy in a Prototheca zopfii outbreak.

    PubMed

    da Costa, Elizabeth Oliveira; Ribeiro, Márcio Garcia; Ribeiro, Andréa Rentz; Rocha, Noeme Sousa; de Nardi Júnior, Geraldo

    2004-07-01

    Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.

  13. A resected perivascular epithelioid cell tumor (PEComa) of the pancreas diagnosed using endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Okuwaki, Kosuke; Kida, Mitsuhiro; Masutani, Hironori; Yamauchi, Hiroshi; Katagiri, Hiroyuki; Mikami, Tetuo; Miyazawa, Shiro; Iwai, Tomohisa; Takezawa, Miyoko; Imaizumi, Hiroshi; Koizumi, Wasaburo

    2013-01-01

    Primary perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare. We herein report our experience with a patient who had a primary PEComa of the pancreas that was diagnosed by the preoperative histopathological examination of a biopsy specimen obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). The patient was a 43-year-old woman whose chief complaint was abdominal pain. Imaging studies revealed a pancreatic tumor. Gastrointestinal stromal tumor (GIST), solid pseudopapillary tumor and neuroendocrine tumor were considered in the differential diagnosis. A histopathological examination of a specimen of the tumor obtained using EUS-FNA showed spindle-shaped tumor cells with enlarged nuclei and eosinophilic cytoplasm. The tumor cells proliferated in a sheet-like fashion and stained positive for the melanoma-associated antigen HMB-45. A PEComa was thus diagnosed. If an adequate tumor specimen can be obtained using EUS-FNA, immunostaining may facilitate the diagnosis of extremely rare diseases and therefore assist in deciding the treatment policy.

  14. Diagnosis of Metastasis to the Thyroid Gland: Comparison of Core-Needle Biopsy and Fine-Needle Aspiration.

    PubMed

    Choi, Sang Hyun; Baek, Jung Hwan; Ha, Eun Ju; Choi, Young Jun; Song, Dong Eun; Kim, Jae Kyun; Chung, Ki-Wook; Kim, Tae Yong; Lee, Jeong Hyun

    2016-04-01

    Early detection and diagnosis of metastasis to the thyroid gland is important. This study aims to evaluate the clinical value of core-needle biopsy (CNB) by comparing the results of CNB and fine-needle aspiration (FNA) in patients with clinically suspected metastasis to the thyroid gland. Case series with chart review. Tertiary referral practice. Fifty-two thyroid nodules from 52 patients with clinically suspected metastasis to the thyroid gland (mean age, 62.8 years). Of these 52 patients, FNA was initially used in 41 patients and CNB in 20 patients (11 patients as the initial approach and 9 patients after inconclusive FNA results). Ultrasound features of metastasis to the thyroid gland were evaluated. The diagnostic performance, repeated diagnostic examination rate, and diagnostic surgery rate were evaluated for FNA and CNB. Among these 52 patients, 46 were diagnosed with thyroid metastases and 6 were diagnosed with primary thyroid cancer. Common ultrasound features were an ovoid to round shape (58.7%), ill-defined margin (56.5%), hypoechogenicity (65.2%), and no calcifications (87.0%). Core-needle biopsy achieved a significantly higher sensitivity than FNA (100.0% vs 58.6%, P = .008) without any false-negative results. Both the repeated diagnostic examination rate and the diagnostic surgery rate were significantly lower in CNB than in FNA (5.0% vs 46.3%, P = .001, and 5.0% vs 34.1%, P = .013, respectively). In cases of known rare primary malignancy, nontypical ultrasound features of primary thyroid malignancy, and need for an additional immunohistochemical analysis, CNB may be primarily considered. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  15. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    PubMed

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  16. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy

    PubMed Central

    2013-01-01

    Background Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. Methodology It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. Results A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). Conclusion CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis. PMID:23402220

  17. [Values and limits in fine needle aspiration in the diagnosis of Warthin tumour of the parotid gland].

    PubMed

    Righi, A; Foschini, M P

    2006-12-01

    Recent paper state that cytological diagnosis of Warthin Tumour of the parotid gland is poorly reproducible and that aspiration procedures damage the tumoral tissue as to make difficult the histological diagnosis. Aim of the present study is to review cytological sampling performed with fine needle sampling without aspiration and to compare them with the relative surgical specimens in order to determine the value of fine needle aspiration in the diagnosis of Warthin Tumour and to quantify' the damage in histological tissue. All cases with cytological and/or histological diagnosis of Warthin Tumour during the period 1/1/98 to 30/6/04 were retrieved. In all cases both cytological and histological slides were reviewed and compared. In all cases fine needle aspiration (FNA) was performed according to the technique described by Zajdela et al. in 1987. A cytologic sample was considered diagnostic when there were in the same sample mucoid substance, lymphocytes scattered with a range of maturation and oncocytes organized in flat sheets of cells. 38 cases were selected corresponding to 37 patients (1 case of Warthin Tumour bilateral): all tumors were localized in the parotid gland. Fine needle sampling were 43. Nine cytological sample (20.9%) were inadequate. Sensitivity and specificity, in the preent series, had the same value, being 97.1%. A spectrum of histologic alterations were observed in 30/38 cases (79%). These alterations were squamous metaplasia (7 cases), acute and chronic hemorrhage and inflammation with multinucleated giant cells (26 cases) and granulation tissue with subsequent fibrosis (24 cases). In all cases the histologic alterations from fine needle were focal, limited to less than 20% of the tumoral area (first category of Batsakis 'classification), and did not prevent the histologic diagnosis of Warthin Tumour. These data suggest that fine needle aspiration without aspiration is a valuable tool for the per-operative diagnosis of Warthin Tumour. In

  18. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    PubMed

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  19. The diagnostic value of thyroglobulin concentration in fine-needle aspiration of the cervical lymph nodes in patients with differentiated thyroid cancer.

    PubMed

    Mikosiński, Sławomir; Pomorski, Lech; Oszukowska, Lidia; Makarewicz, Jacek; Adamczewski, Zbigniew; Sporny, Stanisław; Lewiński, Andrzej

    2006-01-01

    Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and (131)I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15-711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94-100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes in patients with differentiated thyroid cancer.

  20. Fine needle aspiration cytology in lymphadenopathy of HIV-positive cases.

    PubMed

    Saikia, U N; Dey, P; Jindal, B; Saikia, B

    2001-01-01

    To evaluate the role of fine needle aspiration biopsy (FNAB) material in 25 HIV-positive cases with lymphadenopathy. We selected 25 cases for the present study who were enzyme-linked immunosorbent assay positive for HIV (HIV-1). FNAB was performed as a routine, outdoor procedure with informed consent of the patient. For each case, along with routine May-Grünwald-Giemsa and hematoxylin and eosin staining, Ziehl-Neelsen staining for acid-fast bacilli and periodic acid-Schiff staining for fungi were performed wherever necessary. A total of 28 sites were aspirated from 25 HIV patients. All these patients were heterosexual, and none had a history of drug abuse. FNAB was performed under ultrasound guidance in all four cases of a retroperitoneal group of lymph nodes. The most common FNAB diagnosis was reactive lymphoid hyperplasia (10), followed by tuberculosis (8). There were three cases diagnosed as fungal infection (two, Cryptococcus; one, histoplasmosis). FNAB of a case of lymph node was suggestive of tuberculosis. There was one case each diagnosed as non-Hodgkin's lymphoma and squamous cell carcinoma (metastatic). One case of a small axillary lymph node did not yield representative material. FNAB is a relatively inexpensive initial investigative technique in the diagnosis and management of HIV-positive patients. It can obviate the need for surgical excision and enable immediate treatment of specific infections.

  1. Fine needle aspiration cytology of hepatic metastasis from a meningeal hemangiopericytoma. A case report.

    PubMed

    Ghaffar, Hasan; Parwani, Anil; Rosenthal, Dorothy L

    2003-01-01

    Hemangiopericytomas (HPCs) are rare spindle cell tumors, constituting 2.5% of soft tissue neoplasms. Few reports have addressed the fine needle aspiration (FNA) cytology of HPC. We describe the FNA biopsy (FNAB) findings in a 44-year-old patient with a previously resected meningeal hemangiopericytoma. The patient underwent ultrasound-guided FNAB of a 16.0-cm, radiographically heterogeneous density in the liver. The FNA smear showed crowded, ovoid to spindle-shaped cells with poorly defined, scant cytoplasm. The neoplastic cells were positive for CD34 and negative for CD31, factor VIII, glial fibrillary acid protein and cytokeratin AE1/AE3, supporting a diagnosis of HPC and compatible with metastasis from the patient's cerebral tumor. This case documents the role of FNA cytology in confirming HPC.

  2. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    PubMed

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  3. Role of fine needle aspiration cytology in diagnosing filarial arm cysts.

    PubMed

    Tandon, Nishi; Bansal, Cherry; Sharma, Richa; Irfan, Sumaiya

    2013-05-17

    Filariasis is prevalent in tropical and subtropical areas and is endemic in regions of India. Lymphatic filariasis in India is caused mainly by two species of nematodes: Wuchereria bancrofti and Brugia malayi, which invade the human lymphatic system. We report two cases of superficial cystic lesions of the upper limb revealed on fine needle aspiration (FNA) to be clinically unsuspected filariasis. Despite similar aetiologies, both cases revealed variations in aspirate nature, smear morphology and peripheral blood findings. FNA provides definitive diagnosis and is an important tool for diagnosing soft tissue swellings owing to filariasis.

  4. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    PubMed

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  5. Fine-needle aspiration cytology of intraductal papillary-mucinous tumors: a retrospective analysis.

    PubMed

    Layfield, Lester J; Cramer, Harvey

    2005-01-01

    Intraductal papillary-mucinous tumor (IPMT) of the pancreas has become the accepted terminology for a group of mucin-producing epithelial proliferations lying within ectatic segments of the main pancreatic duct or its large branches. These neoplasms generally are associated with an indolent course, characteristic endoscopic ultrasonographic (EUS) findings, and a variable histo- and cytomorphology ranging from hyperplasia to carcinoma. Cytological specimens obtained by endoscopic ultrasound-guided or percutaneous fine-needle aspiration (FNA) are characterized by a background containing abundant mucin in which are entrapped single or loosely cohesive clusters of neoplastic cells characteristically showing a goblet-cell morphology. The degree of nuclear atypia, cell crowding, and cell shape varies between smears within a single case and between cases. Cytomorphological examination, when coupled with EUS features, is accurate for the diagnosis of these lesions but often it underdiagnoses the grade of the neoplasm. (c) 2005 Wiley-Liss, Inc.

  6. Fine needle aspiration cytology of parathyroid lesions.

    PubMed

    Heo, Ilyeong; Park, Sunhoo; Jung, Chang Won; Koh, Jae Soo; Lee, Seung-Sook; Seol, Hyesil; Choi, Hee Seung; Cho, Soo Youn

    2013-10-01

    There has been an increase in the use of fine needle aspiration cytology (FNAC) for the diagnosis of parathyroid lesions (PLs). Differentiation between a thyroid lesion and a PL is not easy because of their similar features. We reviewed parathyroid aspirates in our institution and aimed to uncover trends in diagnostic criteria. We selected 25 parathyroid aspirates (from 6 men and 19 women) confirmed surgically or immunohistochemically from 2006 to 2011. Major architectural findings of PLs include scattered naked nuclei, loose clusters, a papillary pattern with a fibrovascular core, tight clusters, and a follicular pattern. These architectures were commonly admixed with one another. Cytological features included anisokaryosis, stippled chromatin, a well-defined cell border, and oxyphilic cytoplasm. Eighteen of the 25 patients were diagnosed with PL using FNAC. Seven patients had been misdiagnosed with atypical cells (n=2), benign follicular cells (n=2), adenomatous goiter (n=2) and metastatic carcinoma (n=1) in FNAC. Using clinicoradiologic data, the sensitivity of the cytological diagnosis was 86.7%. The cytological sensitivity decreased to 50% without this information. FNAC of PL is easily confused with thyroid lesions. A combination of cytological parameters and clinical data will be required to improve the diagnostic sensitivity of PLs.

  7. Comparison of 21-Gauge and 22-Gauge Aspiration Needle in Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E.; Ray, Cynthia; Greenhill, Sarah R.; Jimenez, Carlos A.; Filner, Joshua; Feller-Kopman, David

    2013-01-01

    Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. Methods: We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. Results: A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). Conclusions: There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle. PMID:23632441

  8. Fine needle aspiration cytology in the management of head and neck masses.

    PubMed

    Slack, R W; Croft, C B; Crome, L P

    1985-04-01

    Fine needle aspiration cytology is a useful technique in the management of patients with masses in the head and neck, which is usually performed in co-operation with a specialized cytopathologist. It has not until recently been an investigation used frequently by British otolaryngologists. This study shows that an aspiration cytology service may be run with the aid of a general histopathologist and demonstrates that it is a valuable aid to diagnosis even without the services of a specialized cytopathologist.

  9. MR-guided fine needle aspiration of breast lesions: Initial experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wald, D.S.; Weinreb, J.C.; Newstead, G.

    1996-01-01

    Fine needle aspiration (FNA) is a minimally invasive procedure that is used to obtain cytologic specimens of suspicious lesions in the breast. The goal of this study was to evaluate the logistics and limitations of MR-guided FNA using a prototype breast localization coil. MR-guided FNAs were attempted on 18 lesions (detected on mammography and/or palpation) in 16 patients. Patients were prone with their compressed mediolaterally between two plates in a circularly polarized RF coil. Lesion position was determined by reference to fiducial makers that corresponded to a grid of holes placed at 5 mm intervals in compression plate. FNA wasmore » performed with a 22G non-ferromagnetic needle. FNA was successful for 11 of 18 lesions (61%). Of the seven unsuccessful cases, there were four in which the lesions were too posteriorly placed to be accessed through the compression plate by the needle. Three cases were too anteriorly placed to be effectively immobilized and, although successfully localized, were insufficiently sampled by the FNA technique. MR-guided FNA is possible using a prototype breast localization device in a select group of patients. Current coil design limits its use in performing MR-guided FNA on the most anteriorly and posteriorly placed breast lesions. Unique requirements of FNA under MR guidance as compared to needle localization and biopsy have been identified. Modifications in localization hardware and cytology aspiration needles should overcome these restrictions. 15 refs., 3 figs.« less

  10. Learning curve of thyroid fine-needle aspiration biopsy.

    PubMed

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Reverse transcriptase polymerase chain reaction on fine needle aspirates for rapid detection of translocations in synovial sarcoma.

    PubMed

    Nilsson, G; Wang, M; Wejde, J; Kanter, L; Karlén, J; Tani, E; Kreicbergs, A; Larsson, O

    1998-01-01

    To evaluate the utilization of fine needle aspiration (FNA) biopsy to obtain material for reverse-transcriptase polymerase chain reaction (RT-PCR) in the detection of the t(X;18)(p11.2;q11.2) translocation in synovial sarcomas. We applied RT-PCR to detection of synovial sarcoma fusion gene transcripts on fine needle aspirates. Five clinical samples were first analyzed: one was a tumor previously diagnosed as malignant hemangiopericytoma, one was a poorly defined tumor, and three were suspected synovial sarcomas. FNA material was transferred directly to the RT-PCR reaction tube without RNA extraction. The t(X;18) translocation could be detected on the limited amount of material that FNA provides. In each of the cases studied the representivity of the tumor samples was confirmed microscopically. Our protocol permits analysis directly on representative samples without extraction of RNA. The results imply that RT-PCR offers reliable detection of sarcoma fusion gene transcripts on fine needle aspirates. The procedure, apart from being applicable to outpatients, is rapid and sensitive.

  12. [Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules].

    PubMed

    Bak, Mihály; Hidvégi, Judit; Andi, Judit; Bahéry, Mária; Kovács, Eszter; Schneider, Ferenc; Kostic, Szilárd; Rényi-Vámos, Ferenc; Szőke, János; Nyári, Tibor; Gődény, Mária; Kásler, Miklós

    2013-01-06

    The methods available for the diagnosis of lung cancer include radiologic, cytologic and pathologic procedures. The aim of this study was to determine the quality assurance of CT guided fine needle aspiration cytology of lung nodules. Cytology results were rated to 4 categories (positive; suspicious; negative; not representative). All cytology reports were compared with the final histology diagnosis. A total of 128 patients underwent CT-guided percutaneous fine-needle aspiration biopsy cytology (63 males; 65 females; mean age 62.8 years). Smears were adequate in 99 cases and inadequate in 29 cases. The average diameter of the nodules was 3.28 cm. Thirty three (25.6%) of the cases were histologically verified and 2 falsely negative and 2 falsely positive cases were detected. The sensitivity and the positive predictive value were 88.8% and 88.8%, respectively. Pneumothorax developed in 7 (5.4%) cases. These results suggest that CT-guided transthoracic fine needle aspiration cytology has a high diagnostic accuracy and an acceptable complication rate. The auditing valves of the results meet the proposed threshold values.

  13. Toward optical guidance during endoscopic ultrasound-guided fine needle aspirations of pancreatic masses using single fiber reflectance spectroscopy: a feasibility study

    NASA Astrophysics Data System (ADS)

    Stegehuis, Paulien L.; Boogerd, Leonora S. F.; Inderson, Akin; Veenendaal, Roeland A.; van Gerven, P.; Bonsing, Bert A.; Sven Mieog, J.; Amelink, Arjen; Veselic, Maud; Morreau, Hans; van de Velde, Cornelis J. H.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Robinson, Dominic J.; Vahrmeijer, Alexander L.

    2017-02-01

    Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ˜5 min. An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p=0.038; 166 μmol/L versus 17 μmol/L, p=0.039, respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.

  14. Evaluating the Minimal Specimens From Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Pancreatic Masses

    PubMed Central

    Park, Joo Kyung; Kang, Ki Joo; Oh, Cho Rong; Lee, Jong Kyun; Lee, Kyu Taek; Jang, Kee Taek; Park, Sang-Mo; Lee, Kwang Hyuck

    2016-01-01

    Abstract Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has become one of the most useful diagnostic modalities for the diagnosis of pancreatic mass. The aim of this study was to investigate the role of analyzing the minimal specimens obtained by EUS-FNA for the diagnosis of solid masses of pancreas. This study consisted of retrospective and prospective analyses. The retrospective study was performed on 116 patients who underwent EUS-FNA of solid masses for cytological smear, histological analysis, and combined analysis including immunohistochemical (IHC) staining. In the prospective study, 79 patients were enrolled to evaluate the quality and accuracy of EUS-FNA histological analysis and feasibility of IHC staining. The final diagnoses of all patients included pancreatic cancer (n = 126), nonpancreatic cancer (n = 21), other neoplasm (n = 27), and benign lesions (n = 21). In our retrospective study, the combined analysis was more sensitive than cytological analysis alone (P < 0.01). The overall sensitivity of cytology, histology, and combined analysis was 69.8%, 67.2%, and 81.8%, respectively. In the prospective analysis, 64.2% of all punctures were helpful for determining the diagnosis and 40.7% provided sufficient tissue for IHC staining. Histological analysis was helpful for diagnosis in 74.7% of patients. IHC staining was necessary for a definite diagnosis in 11.4% of patients, especially in the cases of nonmalignant pancreatic mass. Histological analysis and IHC study of EUS-FNA specimens was useful for the accurate diagnosis of pancreatic and peripancreatic lesions. Combined analysis showed significantly higher sensitivity than cytology alone because IHC staining was helpful for a diagnosis in some patients. PMID:27227937

  15. The Clinical Usefulness of Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy for Rectal and Perirectal Lesions

    PubMed Central

    Soh, Jae Seung; Lee, Ho-Su; Lee, Seohyun; Bae, Jungho; Lee, Hyo Jeong; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho

    2015-01-01

    Background/Aims Endoscopic ultrasound-guided fine needle aspiration and/or biopsy (EUS-FNA/B) have been used to diagnose subepithelial tumors (SETs) and extraluminal lesions in the gastrointestinal tract. Our group previously reported the usefulness of EUS-FNA/B for rectal and perirectal lesions. This study reports our expanded experience with EUS-FNA/B for rectal and perirectal lesions in terms of diagnostic accuracy and safety. We also included our new experience with EUS-FNB using the recently introduced ProCore needle. Methods From April 2009 to March 2014, EUS-FNA/B for rectal and perirectal lesions was performed in 30 consecutive patients. We evaluated EUS-FNA/B performance by comparing histological diagnoses with final results. We also investigated factors affecting diagnostic accuracy. Results Among 10 patients with SETs, EUS-FNA/B specimen results revealed a gastrointestinal stromal tumor in 4 patients and malignant lymphoma in 1 patient. The diagnostic accuracy of EUS-FNA/B was 50% for SETs (5/10). Among 20 patients with non-SET lesions, 8 patients were diagnosed with malignant disease and 7 were diagnosed with benign disease based on both EUS-FNA/B and the final results. The diagnostic accuracy of EUS-FNA/B for non-SET lesions was 75% (15/20). The size of lesions was the only factor related to diagnostic accuracy (P=0.027). Two complications of mild fever and asymptomatic pneumoperitoneum occurred after EUS-FNA/B. Conclusions The overall diagnostic accuracy of EUS-FNA/B for rectal and perirectal lesions was 67% (20/30). EUS-FNA/B is a clinically useful method for cytological and histological diagnoses of rectal and perirectal lesions. PMID:25931998

  16. [On-site fine-needle aspiration cytology of thyroid nodules. Quality assurance of the Bethesda System for Reporting Thyroid Cytopathology (2008)].

    PubMed

    Bak, Mihály; Péter, Ilona; Nyári, Tibor; Simon, Péter; Újlaky, Mátyás; Boér, András; Kásler, Miklós

    2015-10-11

    The methods available for the diagnosis of thyroid nodules include physical examination, imaging, laboratory and fine-needle aspiration cytology tests. The aim of this study was to determine the quality assurance of fine-needle aspiration cytology of thyroid nodules. Cytology results were rated to 6 categories according to the Bethesda System for Reporting Thyroid Cytopathology (2008) (I. nondiagnostic; II. benign; III. atypia of undetermined significance; IV. follicular neoplasia; V. suspicious for malignancy; VI. malignant). All cytology reports were compared with the final histology diagnosis. A total of 1384 patient with thyroid nodule underwent fine-needle aspiration biopsy cytology. Smears were classified I. inadequate in 214 (15.9%); II. benign 986; III. atypical 56; IV. follicular neoplasm 41; V. suspicious for malignancy 18; VI. malignant 33 cases. Two hundred and twenty seven (16.8%) of the cases were operated and histologically verified. The positive predictive value in the benign category was 98.25% and in the malignant 88.46%. The sensitivity of the follicular neoplasm was 66.67%. The results suggest that fine-needle aspiration cytology of thyroid nodules using the Bethesda System for Reporting Thyroid Cytopathology has a high diagnostic accuracy. The auditing values of the results meet the proposed threshold values.

  17. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration With a 19-G Needle Device.

    PubMed

    Tremblay, Alain; McFadden, Seamus; Bonifazi, Martina; Luzzi, Valentina; Kemp, Samuel V; Gasparini, Stefano; Chee, Alex; MacEachern, Paul; Dumoulin, Elaine; A Hergott, Christopher; Shah, Pallav L

    2018-05-16

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration is a well-established first-line minimally invasive modality for mediastinal lymph node sampling. Although results are excellent overall, the technique underperforms in certain situations. We aimed to describe our results using a new 19-G EBUS-guided transbronchial needle aspiration device to determine safety and feasibility of this approach. We completed a retrospective chart review of all cases performed to the time of data analysis at each of 3 study sites. A total of 165 procedures were performed with a total of 297 individual lymph nodes or lesions sampled with the 19-G device by 10 bronchoscopists. Relatively large targets were selected for sampling with the device (mean lymph node size: 20.4 mm; lung lesions: 33.5 mm). A specific diagnosis was obtained in 77.3% of cases with an additional 13.6% of cases with benign lymphocytes, for a procedural adequacy rate of 90.9%. Procedure sample adequacy was 88.6% in suspected malignant cases, 91.0% in suspected sarcoidosis/lymphadenopathy cases, and 85.7% of cases with suspected lymphoma. On a per-node basis, a specific diagnosis was noted in 191/280 (68.2%) of samples, with an additional 61 showing benign lymphocytes for a per-node sample adequacy rate of 90%. One case (0.6%) of intraprocedure bleeding was noted. A new flexible 19-G EBUS needle was successfully and safely applied in a large patient cohort for sampling of lung and enlarged mediastinal lesions with high diagnostic rates across clinical indications.

  18. Endoscopic ultrasound-guided fine-needle aspiration with liquid-based cytologic preparation in the diagnosis of primary pancreatic lymphoma.

    PubMed

    Rossi, Esther Diana; Larghi, Alberto; Verna, Elizabeth C; Martini, Maurizio; Galasso, Domenico; Carnuccio, Antonella; Larocca, Luigi Maria; Costamagna, Guido; Fadda, Guido

    2010-11-01

    The diagnosis subtyping of lymphoma on specimens collected by endoscopic ultrasound fine-needle aspiration (EUS-FNA) can be extremely difficult. When a cytopathologist is available for the on-site evaluation, the diagnosis may be achieved by applying flow cytometric techniques. We describe our experience with immunocytochemistry (ICC) and molecular biology studies applied on EUS-FNA specimens processed with a liquid-based cytologic (LBC) preparation for the diagnosis of primary pancreatic lymphoma (PPL). Three patients with a pancreatic mass underwent EUS-FNA. The collected specimens were processed with the ThinPrep method for the cytologic diagnosis and eventual additional investigations. A morphologic picture consistent with PPL was found on the LBC specimens of the 3 patients. Subsequent ICC and molecular biology studies for immunoglobulin heavy chain gene rearrangement established the diagnosis of pancreatic large B-cell non-Hodgkin lymphoma in 2 patients and a non-Hodgkin lymphoma with plasmoblastic/immunoblastic differentiation in the remaining one. An LBC preparation can be used to diagnose and subtype PPL by applying ICC and molecular biology techniques to specimens collected with EUS-FNA. This method can be an additional processing method for EUS-FNA specimens in centers where on-site cytopathologist expertise is not available.

  19. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Using 19-G Needle for Sarcoidosis.

    PubMed

    Balwan, Akshu

    2018-05-16

    Flexible bronchoscopy with endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is increasingly being used to obtain pathology specimens for diagnosis of sarcoidosis. There is wide variation in reported diagnostic yield in literature. New TBNA needles are available in the market but data are lacking about their diagnostic yield especially for sarcoidosis. This study reports the diagnostic yield of bronchoscopy with EBUS-TBNA using ViziShot FLEX 19-G needle in a series of patients with suspected sarcoidosis. This is a retrospective chart review for diagnostic yield of the 19-G EBUS-TBNA needle for suspected sarcoidosis. Eighty-six EBUS bronchoscopies were performed, 15 were done with clinical suspicion of sarcoidosis. The 19-G needle was used for all cases of suspected sarcoidosis. The procedure was diagnostic of sarcoidosis in 14 (93.3%) patients by TBNA with 1 nondiagnostic bronchoscopy. Procedural diagnostic yield was 93.3%. Eighty-five percent (28/33) of sampled lymph nodes were positive for noncaseating granulomas. The yield of transbronchial lung biopsy (TBLB) and endobronchial lung biopsy was 38% (5/13) and 43% (6/14), respectively. TBLB and endobronchial lung biopsy did not add to the diagnostic yield of the procedure. No significant adverse events were noted. This series reports a higher diagnostic yield than most other published studies and opens platform for direct comparison of each available needle. It also adds to the safety data for this larger needle. In addition, it raises doubt into utility of TBLB for diagnosis of sarcoidosis, which can increase the procedural complications.

  20. Management of cystic or predominantly cystic thyroid nodules: the role of ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Bellantone, Rocco; Lombardi, Celestino Pio; Raffaelli, Marco; Traini, Emanuela; De Crea, Carmela; Rossi, Esther Diana; Fadda, Guido

    2004-01-01

    Conventional fine-needle aspiration biopsy (FNAB) for cystic thyroid nodules (CTNs) has a high rate of nondiagnostic and false-negative results. Ultrasound-guided FNAB (UG-FNAB) permits direct sampling of the wall and/or the solid portion of CTNs, increasing the possibility of a representative sample. In this study we evaluated the role of UG-FNAB in CTNs management. Five-hundred-seventy-five UG-FNAB of CTNs were performed. Thyroidectomy was carried out in 119 of these cases. The medical records of these 119 patients were reviewed and form the basis of this report. The nondiagnostic smear rate was 9.2%. Cytological diagnosis was benign nodule in 42 cases, predominantly follicular lesion in 50 cases, and suspicious or malignant lesion in 16 cases. The final pathology revealed a benign nodule in 98 cases (82.4%) and a carcinoma in 21 (17.6%). The overall accuracy of UG-FNAB was 88.0%. No significant differences were found in age, sex, lesion size, or echographic pattern (p = NS) comparing patients with benign CTNs to patients with malignant CTNs. UG-FNAB has a low rate of nondiagnostic smears and a high overall accuracy in CTNs. All CTNs should undergo UG-FNAB to select patients for surgery, since the malignancy rate is not negligible and no clinical parameter can reliably predict it.

  1. Validation of American Thyroid Association Ultrasound Risk Assessment of Thyroid Nodules Selected for Ultrasound Fine-Needle Aspiration.

    PubMed

    Tang, Alice L; Falciglia, Mercedes; Yang, Huaitao; Mark, Jonathan R; Steward, David L

    2017-08-01

    The aim of this study was to validate the American Thyroid Association (ATA) sonographic risk assessment of thyroid nodules. The ATA sonographic risk assessment was prospectively applied to 206 thyroid nodules selected for ultrasound-guided fine-needle aspiration (US-FNA), and analyzed with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), as well as surgical pathology for the subset undergoing surgical excision. The analysis included 206 thyroid nodules averaging 2.4 cm (range 1-7 cm; standard error of the mean 0.07). Using the ATA US pattern risk assessment, nodules were classified as high (4%), intermediate (31%), low (38%), and very low (26%) risk of malignancy. Nodule size was inversely correlated with sonographic risk assessment, as lower risk nodules were larger on average (p < 0.0001). Malignancy rates determined by cytology/surgical pathology were high 100%, intermediate 11%, low 8%, and very low 2%, which were closely aligned with ATA malignancy risk estimates (high 70-90%, intermediate 10-20%, low 5-10%, and very low 3%). ATA US pattern risk assessment also appropriately predicted the proportion of nodules classified as malignant or suspicious for malignancy through TBSRTC classification-high (77%), intermediate (6%), low (1%), and very low 0%-as well as benign TBSRTC classification-high (0%), intermediate (47%), low (61%), and very low (70%) (p < 0.0001). Malignancy rates of surgically excised, cytologically indeterminate nodules followed ATA sonographic risk stratification (high 100%, intermediate 21%, low 17%, and very low 12%; p = 0.003). This prospective study supports the new ATA sonographic pattern risk assessment for selection of thyroid nodules for US-FNA based upon TBSRTC and surgical pathology results. In the setting of indeterminate cytopathology, nodules categorized as atypia of undetermined significance/follicular lesion of undetermined significance with ATA high-risk sonographic patterns have a high

  2. Image-guided fine-needle aspiration of retroperitoneal masses: The role of the cytopathologist.

    PubMed

    Mehdi, Ghazala; Maheshwari, Veena; Afzal, Sheerin; Ansari, Hena A; Ahmad, Ibne

    2013-01-01

    Retroperitoneal tumors constitute a difficult diagnostic category as they are not easily accessible. The advent of image-guided fine-needle aspiration (FNA) has resolved this problem significantly. We present a short study based on guided aspiration of retroperitoneal tumors, in which we have tried to assess the role of image-guided fine-needle aspiration cytology as a tool for pre-operative diagnosis. The study was conducted on patients diagnosed with retroperitoneal masses. FNA was performed under image guidance with the help of ultrasonography and/or computed tomography; smears were prepared and meticulously screened according to a fixed protocol. The results were analyzed to determine sensitivity, specificity, and diagnostic efficacy of cytopathological diagnosis using image-guided FNA techniques. We assessed 38 patients with retroperitoneal masses. In all cases, adequate cellular material was obtained. No major complications were encountered. Statistical analysis was carried out in 35 cases; sensitivity, specificity, and diagnostic accuracy were 100% in these cases. FNA under image guidance should be considered a first-line diagnostic approach for retroperitoneal and other abdominal tumors, although caution should be exercised in case selection. In areas where advanced tests are not available, the cytotechnologist and cytopathologist have a very important role to play in ensuring accurate diagnoses.

  3. [Quality assurance of fine-needle aspiration cytology of the organized mammography screening].

    PubMed

    Bak, Mihály; Konyár, Eva; Schneider, Ferenc; Bidlek, Mária; Szabó, Eva; Nyári, Tibor; Godény, Mária; Kásler, Miklós

    2010-08-08

    The National Public Health Program has established the organized mammography screening in Hungary. The aim of our study was to determine the quality assurance of breast aspiration cytology. Cytology results were rated to 5 categories (C1, C2, C3, C4 and C5). All cytology reports were compared with the final histology diagnosis. 1361 women had aspiration cytology diagnosis performed from a total of 47718 mammography non-negative lesions. There were 805 (59.1%) benign and 187 (13.7%) malignant alterations. Sensitivity was 91%, specificity 88%, positive predictive value 96.6% and negative predictive value turned to be 71% (p<0.001). The auditing values of fine needle aspiration cytology in our laboratory meet, or in certain aspects exceed the proposed minimum threshold values.

  4. Comparative study between ultrasound-guided fine needle aspiration cytology of axillary lymph nodes and sentinel lymph node histopathology in early-stage breast cancer

    PubMed Central

    Cardoso-Coelho, Lívio Portela; Borges, Rafael Soares; Alencar, Airlane Pereira; Cardoso-Campos-Verdes, Larysse Maira; da Silva-Sampaio, João Paulo; Borges, Umbelina Soares; Gebrim, Luiz Henrique; da Silva, Benedito Borges

    2017-01-01

    The replacement of sentinel lymph node biopsy (SNB) by ultrasound-guided fine-needle aspiration (US-guided FNA) cytology of axillary lymph nodes is controversial, despite the simplicity and reduced cost of the latter. In the present study, US-guided FNA was performed in 27 patients with early-stage breast cancer for comparison with SNB. Data were analyzed by calculation of sample proportions. Tumor subtypes included invasive ductal carcinoma (85%), invasive lobular carcinoma (7%), and tubular and metaplastic carcinoma (4%). FNA had a sensitivity of 45%, specificity of 100%, positive predictive value of 100% and a negative predictive value of 73%. Axillary lymph node cytology obtained by US guided-FNA in patients with breast cancer had a specificity similar to that of sentinel lymph node histopathology in the presence of axillary node metastases. However, when lymph node cytology is negative, it does not exclude the existence of metastatic implants, due to its low sensitivity in comparison to sentinel lymph node histopathology. PMID:28521436

  5. Lung cancer diagnosis and staging with endobronchial ultrasound-guided transbronchial needle aspiration compared with conventional approaches: an open-label, pragmatic, randomised controlled trial

    PubMed Central

    Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M

    2015-01-01

    Summary Background The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. Methods In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Findings Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14–15) than with CDS (29 days; 23–35) resulting in a hazard ratio of 1·98, (1·39–2·82, p<0·0001). One patient in each group had a pneumothorax from a CT-guided biopsy sample; the patient from the CDS group needed intercostal drainage

  6. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  7. Ultrasound guided fine needle aspiration biopsy of parathyroid gland and lesions.

    PubMed

    Dimashkieh, Haytham; Krishnamurthy, Savitri

    2006-03-28

    Parathyroid gland and their tumors comprise a small proportion of non-palpable neck masses that are investigated by ultrasound (US) guided fine needle aspiration biopsy. We reviewed our institution's cases of US guided FNAB of parathyroid gland and their lesions to determine the role of cytology for the preoperative diagnosis of parathyroid gland and their lesions. All cases of FNAB of parathyroid gland and lesions in the last 10 years were reviewed in detail with respect to clinical history and correlated with the histopathologic findings in available cases. The cytologic parameters that were evaluated included cellularity assessed semiquantitatively as scant, intermediate or abundant (<50, 51-500 or >500 cells), cellular distribution (loose clusters, single cells/naked nuclei, rounded clusters, two- and three-dimensional clusters, and presence of prominent vascular proliferation), cellular characteristics (cell size, nuclear shape, presence/absence of a nucleolus, degree of mitosis, amount of cytoplasm, and appearance of nuclear chromatin), and background (colloid-like material and macrophages). Immunostaining for parathyroid hormone (PTH) was performed on selected cases using either destained Pap smears or cell block sections. Twenty cases of US-guided FNAB of parathyroid glands and their lesions including 13 in the expected locations in the neck, 3 in intrathyroid region, 3 in thyroid bed, and 1 metastatic to liver were studied. Majority of the cases showed intermediate cellularity (51-500 cells) with round to oval cells that exhibited a stippled nuclear chromatin, without significant pleomorphism or mitotic activity. The cells were arranged in loose two dimensional groups with many single cells/naked nuclei around the groups. Occasionally macrophages and colloid like material was also encountered. There was no significant difference in the cytomorphologic features between normal gland, hyperplasia adenoma, or carcinoma. Immunocytochemical analysis for PHT was

  8. Pancreatic fine needle aspiration. A comparison of computed tomographic and endoscopic ultrasonographic guidance.

    PubMed

    Qian, Xiaohua; Hecht, Jonathan L

    2003-01-01

    To compare the sensitivity and specificity of pancreatic fine needle aspiration (FNA) with computed tomography (CT) and endoscopic ultrasound (EUS) guidance. A 6-year retrospective review included 137 pancreatic FNAs (CT 51, magnetic resonance imaging 2 or EUS 84). Clinical or histologic follow-up was available for 110 patients. Positive (POS), suspicious (SUS), atypical, negative and unsatisfactory (UNSAT) results represented 25.5%, 7.3%, 7.3%, 40.1% and 19.1% of reported diagnoses, respectively. In detecting malignancy, the sensitivities of POS/SUS results were 71% and 42% for CT and EUS, respectively, with negative predictive value (NPV) of 41% and 45%. Also, 35% of UNSAT results were found to have malignancy. However, EUS was used on more difficult lesions, including 82% of small, cystic ones and 75% of small, solid ones. Although the apparent performance of percutaneous CT-guided biopsies surpasses that of EUS, this is due to the choice of endoscopy for more difficult lesions. The specificity and negative predictive value of EUS and CT are similar.

  9. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    PubMed

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  10. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  11. Endoscopic Ultrasound Guided Fine Needle Aspiration Biopsy in Diagnosis of Pancreatic and Peripancreatic Lesions: A Single Center Experience in Korea

    PubMed Central

    Hwang, Chang Yun; Song, Tae Jun; Moon, Sung-Hoon; Lee, Don; Park, Do Hyun; Seo, Dong Wan; Lee, Sung Koo; Kim, Myung-Hwan

    2009-01-01

    Background/Aims Although endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports about its performance. The aim of this study was to assess the utility of EUS-FNA without on-site cytopathologist in establishing the diagnosis of solid pancreatic and peripancreatic masses from a single institution in Korea. Methods Medical records of 139 patients who underwent EUS-FNA for pancreatic and peripancreatic solid mass in the year 2007, were retrospectively reviewed. By comparing cytopathologic diagnosis of FNA with final diagnosis, sensitivity, specificity, and accuracy were determined, and factors influencing the accuracy as well as complications were analyzed. Results One hundred twenty out of 139 cases had final diagnosis of malignancy. Sensitivity, specificity, and accuracy of EUS-FNA were 82%, 89%, and 83%, respectively, and positive and negative predictive values were 100% and 46%, respectively. As for factors influencing the accuracy of FNA, lesion size was marginally significant (p-value 0.08) by multivariate analysis. Conclusions EUS-FNA performed without on-site cytopathologist was found to be accurate and safe, and thus EUS-FNA should be a part of the standard management algorithm for pancreatic and peripancreatic mass. PMID:20431733

  12. Fine-needle aspiration cytology of hemangiopericytoma: report of two cases.

    PubMed

    Sawh, R N; Lele, S M; Borkowski, J; Ventura, K C; Zaharopoulos, P; Logroño, R

    2000-09-01

    The fine-needle aspiration biopsy (FNAB) findings in two cases of hemangiopericytoma (HP), arising in the parotid gland and on the inner chest wall, respectively, are reported. Smear preparations in each case showed cytologic features of an undifferentiated spindle-cell neoplasm, whereas a core needle biopsy specimen of the chest wall mass showed a spindle-cell tumor with a "staghorn-like" arrangement of endothelium-lined vascular channels. Immunostains performed on this core biopsy, and on the surgical resection specimens in both cases, showed positive staining of tumor cells for vimentin and CD34, with negative staining for a variety of smooth muscle, epithelial, neural, and neuroendocrine markers. Electron microscopy performed in one case further supported the diagnosis of HP. With adequate sampling and appropriate use of ancillary studies, a diagnosis of HP can be reliably suggested on the basis of FNAB and core biopsy of a soft-tissue mass. Copyright 2000 Wiley-Liss, Inc.

  13. Ultrasound-guided fine-needle aspiration of a posterior neck dedifferentiated liposarcoma with MDM2 fluorescence in situ hybridization performed on a Pap-stained smear.

    PubMed

    Zreik, Riyam; Soyalp, Krystal; Ruiz, Steve; Ward, Russell; Dobin, Sheila; Chen, Xiangbai; Liu, Lina; Rao, Arundhati

    2015-04-01

    Head and neck liposarcomas, while rare, tend to be subcutaneous and well-differentiated. Dedifferentiated liposarcomas of the head and neck are exceedingly rare in the literature. We present a case of a dedifferentiated liposarcoma arising in the soft tissue of the posterior neck of an 86-year-old man and diagnosed by fine-needle aspiration. Aspirate smears showed a dual population of atypical lipomatous and spindled cells. MDM2 (murine double minute 2) amplification was demonstrated on a Pap-stained smear using fluorescence in situ hybridization (FISH). To the best of our knowledge, this is the first report of MDM2 FISH amplification in a liposarcoma performed on an aspirate smear. © 2014 Wiley Periodicals, Inc.

  14. Papular skin lesions: Clue to a recurrence of breast cancer on fine needle non-aspiration cytology (FNNAC)

    PubMed Central

    Afrose, Ruquiya; Akram, Mohammad; Siddiqui, Shahid Ali

    2015-01-01

    Cutaneous metastasis from underlying carcinoma is relatively uncommon in clinical practice. A high index of suspicion is required to diagnose these lesions, as these lesions can mimic benign skin lesions and clinical findings may be subtle. Fine needle aspiration cytology (FNAC) is commonly employed for diagnosing these skin lesions. However, it is often difficult to aspirate adequate material from small papular lesions. In these clinical situations, fine needle non-aspiration cytology (FNNAC) is proposed as an alternative procedure. FNNAC eliminates the negative suction pressure employed in FNAC and decreases the dilution of tumor cells by blood and hence yields adequate diagnostic material. We report here a case in which FNNAC was used in place of FNAC in diagnosing papular skin lesions. This procedure was carried out in a treated patient of carcinoma breast who was on regular follow-up and presented to us with a 20-day history of papular skin lesions over the chest and back. This article enlightens the clinicians about the utility of FNNAC, which is a relatively uncommon procedure. PMID:25948954

  15. Papular skin lesions: Clue to a recurrence of breast cancer on fine needle non-aspiration cytology (FNNAC).

    PubMed

    Afrose, Ruquiya; Akram, Mohammad; Siddiqui, Shahid Ali

    2015-01-01

    Cutaneous metastasis from underlying carcinoma is relatively uncommon in clinical practice. A high index of suspicion is required to diagnose these lesions, as these lesions can mimic benign skin lesions and clinical findings may be subtle. Fine needle aspiration cytology (FNAC) is commonly employed for diagnosing these skin lesions. However, it is often difficult to aspirate adequate material from small papular lesions. In these clinical situations, fine needle non-aspiration cytology (FNNAC) is proposed as an alternative procedure. FNNAC eliminates the negative suction pressure employed in FNAC and decreases the dilution of tumor cells by blood and hence yields adequate diagnostic material. We report here a case in which FNNAC was used in place of FNAC in diagnosing papular skin lesions. This procedure was carried out in a treated patient of carcinoma breast who was on regular follow-up and presented to us with a 20-day history of papular skin lesions over the chest and back. This article enlightens the clinicians about the utility of FNNAC, which is a relatively uncommon procedure.

  16. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    PubMed Central

    Raquel, Garza-Guajardo; Nora, Mendez-Olvera; Pablo, Flores-Gutierrez Juan; Silvia, Hernandez-Martinez; Michelle, Candanosa-Mc Cann; Jesús, Ancer-Rodriguez; Oralia, Barboza-Quintana

    2005-01-01

    Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures. PMID:16174298

  17. Papanicolaou Society of Cytopathology new guidelines have a greater ability of risk stratification for pancreatic endoscopic ultrasound-guided fine-needle aspiration specimens

    PubMed Central

    Chen, Bo; Zhao, Yu; Gu, Jiangang; Wu, Huanwen; Liang, Zhiyong; Meng, Zhilan

    2017-01-01

    The Papanicolaou Society of Cytopathology has recently proposed a standardized terminology and nomenclature guidelines for pancreatic cytology. However the risk of malignancy associated with the new guidelines has been scarcely studied. In this study, a series of pancreatic cytology cases obtained by endoscopic ultrasound-guided fine-needle aspiration from 294 Chinese patients were retrospectively re-categorized into six categories according the new guidelines. The risks of malignancy were 18.1% for “negative,” 20.0% for “neoplastic,” 57.1% for “nondiagnostic,” 69.2% for “atypical,” 87.5% for “suspicious,” and 100.0% for “positive” respectively. The area under the receiver operating characteristic curve was 0.93 (95% Confidence Interval, 0.90-0.96), which was significantly higher than that associated with old classification system (0.82; 95% Confidence Interval, 0.77-0.87) conventionally used in China. Our investigation demonstrated that the new guidelines have a greater ability of risk stratification than the old classification system conventionally used in China. This may be helpful in giving better predictions of malignancy, thus leading to more personalized treatment strategies. PMID:28042957

  18. The comparative effectiveness of fine-needle aspiration cytology sampling policies: a simulation study.

    PubMed

    Schmidt, Robert L; Howard, Kirsten; Hall, Brian J; Layfield, Lester J

    2012-12-01

    Sample adequacy is an important aspect of overall fine-needle aspiration cytology (FNAC) performance. FNAC effectiveness is augmented by an increasing number of needle passes, but increased needle passes are associated with higher costs and greater risk of adverse events. The objective of this study was to compare the impact of several different sampling policies on FNAC effectiveness and adverse event rates using discrete event simulation. We compared 8 different sampling policies in 12 different sampling environments. All sampling policies were effective when the per-pass accuracy is high (>80%). Rapid on-site evaluation (ROSE) improves FNAC effectiveness when the per-pass adequacy rate is low. ROSE is unlikely to be cost-effective in sampling environments in which the per-pass adequacy is high. Alternative ROSE assessors (eg, cytotechnologists) may be a cost-effective alternative to pathologists when the per-pass adequacy rate is moderate (60%-80%) or when the number of needle passes is limited.

  19. Incisional endometriosis: diagnosed by fine needle aspiration cytology.

    PubMed

    Veda, P; Srinivasaiah, M

    2010-07-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03-1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE.

  20. Incisional Endometriosis: Diagnosed by Fine Needle Aspiration Cytology

    PubMed Central

    Veda, P; Srinivasaiah, M

    2010-01-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03–1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE. PMID:21346911

  1. P-LUM-08: Endoscopic ultrasound-guided fine needle aspiration: A new modality to diagnose peritoneal tuberculosis in the presence of decompensated cirrhosis – a case series

    PubMed Central

    Daswani, Ravi; Singla, Vikas; Arora, Anil; Sharma, Praveen; Bansal, Naresh; Kumar, Ashish

    2017-01-01

    The gold standard for diagnosis of peritoneal tuberculosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the nonspecific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low, and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Thus, there is an urgent need to explore newer diagnostic modalities, especially those that can provide perioneal tissue by less invasive means. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal tuberculosis (TB). We hereby report the use of EUS- FNA of the peritoneum in five patients with decompensated cirrhosis, in whom the diagnosis could not be confirmed by other means; thus, we propose EUS-FNA of the peritoneum as a new, safe, and unexplored technique for diagnosis of peritoneal TB.

  2. High-resolution endoscopic ultrasound imaging and the number of needle passages are significant factors predicting high yield of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses without an on-site cytopathologist

    PubMed Central

    Jeong, Seok Hoo; Yoon, Hyun Hwa; Kim, Eui Joo; Kim, Yoon Jae; Kim, Yeon Suk; Cho, Jae Hee

    2017-01-01

    Abstract Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the accurate diagnostic method for pancreatic masses and its accuracy is affected by various FNA methods and EUS equipment. Therefore, we aimed to elucidate the instrumental and methodologic factors for determining the diagnostic yield of EUS-FNA for pancreatic solid masses without an on-site cytopathology evaluation. We retrospectively reviewed the medical records of 260 patients (265 pancreatic solid masses) who underwent EUS-FNA. We compared historical conventional EUS groups with high-resolution imaging devices and finally analyzed various factors affecting EUS-FNA accuracy. In total, 265 pancreatic solid masses of 260 patients were included in this study. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of EUS-FNA for pancreatic solid masses without on-site cytopathology evaluation were 83.4%, 81.8%, 100.0%, 100.0%, and 34.3%, respectively. In comparison with conventional image group, high-resolution image group showed the increased accuracy, sensitivity and specificity of EUS-FNA (71.3% vs 92.7%, 68.9% vs 91.9%, and 100% vs 100%, respectively). On the multivariate analysis with various instrumental and methodologic factors, high-resolution imaging (P = 0.040, odds ratio = 3.28) and 3 or more needle passes (P = 0.039, odds ratio = 2.41) were important factors affecting diagnostic yield of pancreatic solid masses. High-resolution imaging and 3 or more passes were the most significant factors influencing diagnostic yield of EUS-FNA in patients with pancreatic solid masses without an on-site cytopathologist. PMID:28079803

  3. IAC Standardized Reporting of Breast Fine-Needle Aspiration Biopsy Cytology.

    PubMed

    Field, Andrew S; Schmitt, Fernando; Vielh, Philippe

    2017-01-01

    There have been many changes in the roles of fine-needle aspiration biopsy (FNAB) and core needle biopsy (CNB) in the diagnostic workup of breast lesions in routine breast clinics and in mammographic breast screening programs, as well as changes in the management algorithms utilized and the treatments available, since the NCI consensus on breast FNAB cytology in 1996. A standardized approach will improve training and performance of FNAB and smear-making techniques, and structured reporting will improve the quality and reproducibility of reports across departments, cities and countries providing a basis for quality assurance measures and improving patient care and facilitating research. Linking cytology reports to management algorithms will increase the clinicians' use of FNAB cytology and where appropriate CNB, and enhance the use of ancillary tests for prognostic testing. The IAC recognizes that the local medical infrastructure and resources for breast imaging, biopsy and treatment will influence the diagnostic workup and management of breast disease, but best practice guidelines should be established and modified as required. © 2016 S. Karger AG, Basel.

  4. Cost-effectiveness comparison between palpation- and ultrasound-guided thyroid fine-needle aspiration biopsies.

    PubMed

    Can, Ahmet Selçuk

    2009-05-16

    The aim of this study is to perform a cost-effectiveness comparison between palpation-guided thyroid fine-needle aspiration biopsies (P-FNA) and ultrasound-guided thyroid FNA biopsies (USG-FNA). Each nodule was considered as a case. Diagnostic steps were history and physical examination, TSH measurement, Tc99m thyroid scintigraphy for nodules with a low TSH level, initial P-FNA versus initial USG-FNA, repeat USG-FNA for nodules with initial inadequate P-FNA or USG-FNA, hemithyroidectomy for inadequate repeat USG-FNA. American Thyroid Association thyroid nodule management guidelines were simulated in estimating the cost of P-FNA strategy. American Association of Clinical Endocrinologists guidelines were simulated for USG-FNA strategy. Total costs were estimated by adding the cost of each diagnostic step to reach a diagnosis for 100 nodules. Strategy cost was found by dividing the total cost to 100. Incremental cost-effectiveness ratio (ICER) was calculated by dividing the difference between strategy cost of USG-FNA and P-FNA to the difference between accuracy of USG-FNA and P-FNA. A positive ICER indicates more and a negative ICER indicates less expense to achieve one more additional accurate diagnosis of thyroid cancer for USG-FNA. Seventy-eight P-FNAs and 190 USG-FNAs were performed between April 2003 and May 2008. There were no differences in age, gender, thyroid function, frequency of multinodular goiter, nodule location and diameter (median nodule diameter: 18.4 mm in P-FNA and 17.0 mm in USG-FNA) between groups. Cytology results in P-FNA versus USG-FNA groups were as follows: benign 49% versus 62% (p = 0.04), inadequate 42% versus 29% (p = 0.03), malignant 3% (p = 1.00) and indeterminate 6% (p = 0.78) for both. Eleven nodules from P-FNA and 18 from USG-FNA group underwent surgery. The accuracy of P-FNA was 0.64 and USG-FNA 0.72. Unit cost of P-FNA was 148 Euros and USG-FNA 226 Euros. The cost of P-FNA strategy was 534 Euros and USG-FNA strategy 523 Euros

  5. Cost-effectiveness comparison between palpation- and ultrasound-guided thyroid fine-needle aspiration biopsies

    PubMed Central

    Can, Ahmet Selçuk

    2009-01-01

    Background The aim of this study is to perform a cost-effectiveness comparison between palpation-guided thyroid fine-needle aspiration biopsies (P-FNA) and ultrasound-guided thyroid FNA biopsies (USG-FNA). Methods Each nodule was considered as a case. Diagnostic steps were history and physical examination, TSH measurement, Tc99m thyroid scintigraphy for nodules with a low TSH level, initial P-FNA versus initial USG-FNA, repeat USG-FNA for nodules with initial inadequate P-FNA or USG-FNA, hemithyroidectomy for inadequate repeat USG-FNA. American Thyroid Association thyroid nodule management guidelines were simulated in estimating the cost of P-FNA strategy. American Association of Clinical Endocrinologists guidelines were simulated for USG-FNA strategy. Total costs were estimated by adding the cost of each diagnostic step to reach a diagnosis for 100 nodules. Strategy cost was found by dividing the total cost to 100. Incremental cost-effectiveness ratio (ICER) was calculated by dividing the difference between strategy cost of USG-FNA and P-FNA to the difference between accuracy of USG-FNA and P-FNA. A positive ICER indicates more and a negative ICER indicates less expense to achieve one more additional accurate diagnosis of thyroid cancer for USG-FNA. Results Seventy-eight P-FNAs and 190 USG-FNAs were performed between April 2003 and May 2008. There were no differences in age, gender, thyroid function, frequency of multinodular goiter, nodule location and diameter (median nodule diameter: 18.4 mm in P-FNA and 17.0 mm in USG-FNA) between groups. Cytology results in P-FNA versus USG-FNA groups were as follows: benign 49% versus 62% (p = 0.04), inadequate 42% versus 29% (p = 0.03), malignant 3% (p = 1.00) and indeterminate 6% (p = 0.78) for both. Eleven nodules from P-FNA and 18 from USG-FNA group underwent surgery. The accuracy of P-FNA was 0.64 and USG-FNA 0.72. Unit cost of P-FNA was 148 Euros and USG-FNA 226 Euros. The cost of P-FNA strategy was 534 Euros and USG

  6. Endoscopic ultrasound-guided fine-needle aspiration for suspected malignancies adjacent to the gastrointestinal tract.

    PubMed

    Gambitta, Pietro; Armellino, Antonio; Forti, Edoardo; Vertemati, Maurizio; Colombo, Paola Enrica; Aseni, Paolo

    2014-07-14

    To investigate the impact of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in association with a multidisciplinary team evaluation for the detection of gastrointestinal malignancies. A cohort of 1019 patients with suspected malignant lesions adjacent to the gastrointestinal tract received EUS-FNA after a standardized multidisciplinary team evaluation (MTE) and were divided into 4 groups according to their specific malignant risk score (MRS). Patients with a MRS of 0 (without detectable risk of malignancy) received only EUS without FNA. For patients with a MRS score ranging from 1 (low risk) - through 2 (intermediate risk) - to 3 (high risk), EUS-FNA cytology of the lesion was planned for a different time and was prioritized for those patients at higher risk for cancer. The accuracy, efficiency and quality assessment for the early detection of patients with potentially curable malignant lesions were evaluated for the whole cohort and in the different classes of MRSs. The time to definitive cytological diagnosis (TDCD), accuracy, sensitivity, specificity, positive and negative predictive values, and the rate of inconclusive tests were calculated for all patients and for each MRS group. A total of 1019 patients with suspected malignant lesions were evaluated by EUS-FNA. In 515 patients of 616 with true malignant lesions the tumor was diagnosed by EUS-FNA; 421 patients with resectable lesions received early surgical treatment, and 94 patients received chemo-radiotherapy. The overall diagnostic accuracy for the 1019 lesions in which a final diagnosis was obtained by EUS-FNA was 0.95. When patients were stratified by MTE into 4 classes of MRSs, a higher rate of patients in the group with higher cancer risk (MRS-3) received early treatment and EUS-FNA showed the highest level of accuracy (1.0). TDCD was also shorter in the MRS-3 group. The number of patients who received surgical treatment or chemo-radiotherapy was significantly higher in the MRS-3 patient

  7. Effectiveness of Toyota process redesign in reducing thyroid gland fine-needle aspiration error.

    PubMed

    Raab, Stephen S; Grzybicki, Dana Marie; Sudilovsky, Daniel; Balassanian, Ronald; Janosky, Janine E; Vrbin, Colleen M

    2006-10-01

    Our objective was to determine whether the Toyota Production System process redesign resulted in diagnostic error reduction for patients who underwent cytologic evaluation of thyroid nodules. In this longitudinal, nonconcurrent cohort study, we compared the diagnostic error frequency of a thyroid aspiration service before and after implementation of error reduction initiatives consisting of adoption of a standardized diagnostic terminology scheme and an immediate interpretation service. A total of 2,424 patients underwent aspiration. Following terminology standardization, the false-negative rate decreased from 41.8% to 19.1% (P = .006), the specimen nondiagnostic rate increased from 5.8% to 19.8% (P < .001), and the sensitivity increased from 70.2% to 90.6% (P < .001). Cases with an immediate interpretation had a lower noninterpretable specimen rate than those without immediate interpretation (P < .001). Toyota process change led to significantly fewer diagnostic errors for patients who underwent thyroid fine-needle aspiration.

  8. Diagnosis of peritoneal mesothelioma: computed tomography, sonography, and fine-needle aspiration biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reuter, K.; Raptopoulos, V.; Reale, F.

    1983-06-01

    The diagnosis of peritoneal mesothelioma was made prospectively and noninvasively in four patients with the use of sonography, computed tomography, and sonographically guided fine-needle aspiration biopsy. The imaging methods revealed information similar to the operative findings, with clear superiority of computed tomography over sonography. These noninvasive methods may be used as screening tools, especially among groups or in regional areas with a high risk for asbestos exposure. The findings included soft-tissue masses with invariable involvement of the omentum; small intraperitoneal nodules; thickened peritoneum, mesentery, and bowel wall; pleural plaques; and usually minimal, if any, ascites. Since the differential diagnosis frommore » peritoneal carcinomatosis may be difficult, sonographically (or CT) guided aspiration biopsy is needed to produce diagnostic cytologic specimens. The use of this type of biopsy should obviate surgical exploration.« less

  9. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration.

    PubMed

    Arakawa, H; Nakajima, Y; Kurihara, Y; Niimi, H; Ishikawa, T

    1996-07-01

    We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.

  10. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    PubMed Central

    Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre

    2011-01-01

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer. PMID:24212643

  11. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session

    PubMed Central

    Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.

    2014-01-01

    Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096

  12. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems.

    PubMed

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA", which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%" on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a

  13. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    PubMed Central

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid

  14. Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings

    PubMed Central

    Lee, Mi-Jung; Hong, Soon Won; Chung, Woung Youn; Kwak, Jin Young; Kim, Min Jung

    2011-01-01

    Purpose To compare the cytological results of ultrasound-guided fine-needle aspiration (US-FNA) cytology of thyroid nodules to sonographic findings and determine whether US findings are helpful in the interpretation of cytological results. Materials and Methods Among the thyroid nodules that underwent US-FNA cytology, we included the 819 nodules which had a conclusive diagnosis. Final diagnosis was based on pathology from surgery, repeated FNA cytology or follow-up of more than one year. Cytological results were divided into five groups: benign, indeterminate (follicular or Hurthle cell neoplasm), suspicious for malignancy, malignant, and inadequate. US findings were categorized as benign or suspicious. Cytological results and US categories were analyzed. Results Final diagnosis was concluded upon in 819 nodules based on pathology (n=311), repeated FNA cytology (n=204) and follow-up (n=304), of which 634 were benign and 185 were malignant. There were 560 benign nodules, 141 malignant nodules, 49 nodules with inadequate results, 21 with indeterminate results, and 48 that were suspicious for malignancy. The positive and negative predictive values of the US categories were 59.1% and 97.0%, and those of the cytological results were 93.7% and 98.9%. The US categories were significantly correlated with final diagnosis in the benign (p=0.014) and suspicious for malignancy (p<0.001) cytological result groups, but not in the inadequate and indeterminate cytological results groups. The false positive and negative rates of cytological results were 1.9% and 3.2%. Conclusion Sonographic findings can be useful when used alongside cytological results, especially in nodules with cytological results that are benign or suspicious for malignancy. PMID:21786450

  15. Fine-needle aspiration biopsy of the salivary gland: problem cases.

    PubMed

    MacLeod, C B; Frable, W J

    1993-01-01

    Among 582 fine-needle aspiration (FNA) biopsies of major and minor salivary glands performed between 1974 and 1990, lack of cytological histologic correlation was noted in 21 cases. Of these, the cause in 10 FNAs was inadequate cytological sampling of the lesion. [One case of malignant hemangiopericytoma was tentatively diagnosed as a monomorphic adenoma on FNA, a polymorphic T-cell lymphoma was diagnosed as granulomatous inflammation on aspiration biopsy, a benign lymphoepithelial lesion was diagnosed as a reactive lymph node, a branchial cleft cyst was called benign mixed tumor (BMT), one case of chronic sialoadenitis was called BMT by FNA, two cases of benign lymphoepithelial lesion (BLEL) were diagnosed as cystic Warthin's tumor, two low-grade mucoepidermoid carcinomas were called BMT, and a BMT was cytologically diagnosed as a Warthin's tumor with squamous metaplasia versus low-grade mucoepidermoid carcinoma. One case of low-grade mucoepidermoid carcinoma was diagnosed only as a "cyst."] Review of these cases identifies constant features that permit differentiation between Warthin's tumor and BLEL, and among BMT, mucoepidermoid carcinoma, and chronic sialoadenitis. Despite a few problem cases, FNA of the salivary gland is accurate in the preoperative diagnosis and classification of salivary gland neoplasms.

  16. Percutaneous transhepatic cholangiographic endobiliary forceps biopsy versus endoscopic ultrasound fine needle aspiration for proximal biliary strictures: a single-centre experience.

    PubMed

    Mohkam, Kayvan; Malik, Yaseen; Derosas, Carlos; Isaac, John; Marudanayagam, Ravi; Mehrzad, Homoyoon; Mirza, Darius F; Muiesan, Paolo; Roberts, Keith J; Sutcliffe, Robert P

    2017-06-01

    Endoscopic ultrasound fine needle aspiration (EUS-FNA) and percutaneous transhepatic cholangiographic endobiliary forceps biopsy (PTC-EFB) are valid procedures for histological assessment of proximal biliary strictures (PBS), but their performances have never been compared. This study aimed to compare the diagnostic performance of these two techniques. The diagnostic performances of EUS-FNA and PTC-EFB were compared in a retrospective cohort of patients assessed for PBS from 2011 to 2015 at a single tertiary centre. An inverse probability of treatment weighting (IPTW) was performed to adjust for covariate imbalance. A total of 102 EUS-FNAs and 75 PTC-EFBs (performed in 137 patients) were compared. Patients in the PTC-EFB group had higher preoperative bilirubin (243 versus 169 μmol/l, p = 0.005) and a higher incidence of malignancy (87% versus 67%, p = 0.008). Both techniques showed specificity and positive predictive value of 100%, and similar sensitivity (69% versus 75%, p = 0.45), negative predictive value (58% versus 38%, p = 0.15) and accuracy (78% versus 79%, p = 1.00). After IPTW, the diagnostic performance of the two techniques remained similar. Compared to EUS-FNA, PTC-EFB provides similar sensitivity, negative predictive value and accuracy. It should therefore be considered as the preferred tissue-sampling procedure, if biliary drainage is indicated. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  17. Endoscopic ultrasound-guided fine needle aspiration cytology diagnosis of solid pseudopapillary tumor of the pancreas: a report of 3 cases.

    PubMed

    Chatzipantelis, Paschalis; Salla, Charitini; Apostolou, George; Christodoulou, Lambrini; Kakiopoulos, George; Patralexis, Charalambos

    2010-01-01

    Solid pseudopapillary tumor of the pancreas (SPTP) is an exceedingly rare pancreatic tumor. We present the clinical, endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) cytologic features and immunohistochemical findings performed on cell blocks of 3 SPTPs. Three females (17-32 years old) were admitted to our hospital due to unexplained episodic abdominal pain. EUS confirmed the presence of a mass in the body and tail of the pancreas (2 cases) and in the head (1 case), with distinct borders and occassional dilation of the peripheral part of the pancreatic duct. EUS-FNA cytology specimens consisted of single cells and aggregates of uniform polyhedral cells, forming branching papillary clusters with delicate fibrovascular cores and nuclear overlapping (2 cases) and glandlike structures (1 case). Variable hyaline, myxoid stromal elements and naked capillaries were also seen. The cells had bland nuclear features, small nucleoli, nuclear grooves in some of them and focally cytoplasmic projections. Mitoses and necrosis were not observed. The immunohistochemistry on cell blocks revealed: vimentin+ (3 cases), CA19.9+ (2 cases), cytokeratin 7+ (focal, intensive, 1 case), synaptophysin+ (1 case), MUC1+ (focal, intensive, 1 case), EMA+ (diffuse weak, 1 case), a1-antitrypsin and a1-antichymotrypsin+ (focal intensive, 2 cases), progesterone+ (1 case), chromogranin-A- (3 cases) and NSE- (3 cases). Cytologic and immunohistochemical findings were strongly suggestive of SPTP. Surgical resection confirmed the diagnosis in all cases. EUS-FNA cytology features and immunohistochemistry provide the diagnosis of SPTP with accuracy.

  18. A correlation study of diagnostic fine-needle aspiration with histologic diagnosis in cystic neck lesions.

    PubMed

    Moatamed, Neda A; Naini, Bita V; Fathizadeh, Payman; Estrella, Julie; Apple, Sophia K

    2009-10-01

    The clinical diagnosis of a mass in the neck region encompasses a wide spectrum of differential diagnosis. Fine-needle aspiration is a quick and safe technique, which can provide useful information for initial assessment and further therapeutic measures. The aim of this retrospective study was to evaluate the performance characteristics of the fine-needle aspiration (FNA) in cystic neck lesions. Of 142 patients with FNA for cystic neck masses during 2002-2007, 92 cases were selected with a follow-up histologic diagnosis, excluding the cystic colloid nodule of the thyroid. The cases were divided into salivary gland cystic neck (37 patients) and non-salivary cystic neck (55 patients) mass groups. False-positive and false-negative diagnoses were applied only to the malignant lesions after confirmation by histopathology. In the first group, nine malignant and 28 benign diagnoses were made by FNA; of which three were false-negative. In the second group, there were nine malignant and 46 benign diagnoses with three false negatives. The overall performance of the FNA showed 76% sensitivity and 100% specificity. In conclusion, FNA of the cystic neck lesions offers an invaluable and highly specific initial diagnostic approach for the management of the patients. (c) 2009 Wiley-Liss, Inc.

  19. The relevance of ultrasound imaging of suspicious axillary lymph nodes and fine-needle aspiration biopsy in the post ACOSOG Z11 era in early breast cancer

    PubMed Central

    Vijayaraghavan, Gopal R.; Vedantham, Srinivasan; Kataoka, Milliam; DeBenedectis, Carolynn; Quinlan, Robert

    2016-01-01

    Rationale and Objective Evaluation of nodal involvement in early-stage breast cancers (T1 or T2) changed following the Z11 trial; however, not all patients meet the Z11 inclusion criteria. Hence, the relevance of ultrasound imaging of the axilla and fine-needle aspiration biopsy (FNA) in early-stage breast cancers was investigated. Materials and Methods In this single-center, retrospective study, 758 subjects had pathology-verified breast cancer diagnosis over a 3-year period, of which 128 subjects with T1/T2 breast tumors had abnormal axillary lymph nodes on ultrasound, had FNA, and proceeded to axillary surgery. Ultrasound images were reviewed and analyzed using multivariable logistic regression to identify the features predictive of positive FNA. Accuracy of FNA was quantified as the area under the receiver operating characteristic curve with axillary surgery as reference standard. Results Of 128 subjects, 61 and 65 were positive on FNA and axillary surgery, respectively. Sensitivity, specificity, positive- and negative-predictive values of FNA were 52/65 (80%), 54/63 (85.7%), 52/61(85.2%) and 54/67 (80.5%), respectively. After adjusting for neoadjuvant chemotherapy between FNA and surgery, a positive FNA was associated with higher likelihood for positive axillary surgery (odds ratio: 22.7; 95% CI: 7.2–71.3, p<0.0001), and the accuracy of FNA was 0.801 (95% CI: 0.727–0.876). Among ultrasound imaging features, cortical thickness and abnormal hilum were predictive (p<0.017) of positive FNA with accuracy of 0.817 (95% CI: 0.741–0.893). Conclusion Ultrasound imaging and FNA can play an important role in the management of early breast cancers even in the post-Z11 era. Higher weightage can be accorded to cortical thickness and hilum during ultrasound evaluation. PMID:27916595

  20. Reliable Gene Expression Measurements from Fine Needle Aspirates of Pancreatic Tumors

    PubMed Central

    Anderson, Michelle A.; Brenner, Dean E.; Scheiman, James M.; Simeone, Diane M.; Singh, Nalina; Sikora, Matthew J.; Zhao, Lili; Mertens, Amy N.; Rae, James M.

    2010-01-01

    Background and aims: Biomarker use for pancreatic cancer diagnosis has been impaired by a lack of samples suitable for reliable quantitative RT-PCR (qRT-PCR). Fine needle aspirates (FNAs) from pancreatic masses were studied to define potential causes of RNA degradation and develop methods for accurately measuring gene expression. Methods: Samples from 32 patients were studied. RNA degradation was assessed by using a multiplex PCR assay for varying lengths of glyceraldehyde-3-phosphate dehydrogenase, and effects on qRT-PCR were determined by using a 150-bp and a 80-bp amplicon for RPS6. Potential causes of and methods to circumvent RNA degradation were studied by using FNAs from a pancreatic cancer xenograft. Results: RNA extracted from pancreatic mass FNAs was extensively degraded. Fragmentation was related to needle bore diameter and could not be overcome by alterations in aspiration technique. Multiplex PCR for glyceraldehyde-3-phosphate dehydrogenase could distinguish samples that were suitable for qRT-PCR. The use of short PCR amplicons (<100 bp) provided reliable gene expression analysis from FNAs. When appropriate samples were used, the assay was highly reproducible for gene copy number with minimal (0.0003 or about 0.7% of total) variance. Conclusions: The degraded properties of endoscopic FNAs markedly affect the accuracy of gene expression measurements. Our novel approach to designate specimens “informative” for qRT-PCR allowed accurate molecular assessment for the diagnosis of pancreatic diseases. PMID:20709792

  1. Repeat Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Patients with Suspected Pancreatic Cancer: Diagnostic Yield and Associated Change in Access to Appropriate Care

    PubMed Central

    Stanger, Dylan; Shuster, Constantin; Telford, Jennifer; Lam, Eric

    2016-01-01

    Background. There is a high incidence of inconclusive cytopathology at initial EUS-FNA (endoscopic ultrasound-guided fine-needle aspiration) for suspected malignant pancreatic lesions. To obtain appropriate preoperative or palliative chemotherapy for pancreatic cancer, definitive cytopathology is often required. The utility of repeat EUS-FNA is not well established. Methods. A retrospective cohort study was conducted evaluating the yield of repeat EUS-FNA in determining a cytological diagnosis in patients who had undergone a prior EUS-FNA for diagnosis of suspected malignant pancreatic lesions with inconclusive cytopathology. The wait times to the second procedure and to decisions regarding therapy were calculated. Results. Overall, 45 repeat EUS-FNA procedures were performed over seven years for suspected malignant pancreatic lesions. Cytopathological class (I to IV) changed between first and second EUS-FNA in 32 patients (71%). Of 34 patients with an initially nonconclusive diagnosis, 20 had a conclusive diagnosis (59%) on repeat EUS-FNA. The cumulative yield after repeat EUS-FNA for definite pancreatic adenocarcinoma was 7 (16%). The median time interval between first and second EUS-FNA was 31 (7–175) days. Conclusions. A substantial number of patients had a definitive diagnosis of adenocarcinoma on repeat FNA and were, therefore, subsequently able to access appropriate care. PMID:27648440

  2. Perivascular Epithelioid Cell Tumor (PEComa) of Pancreas Diagnosed Preoperatively by Endoscopic Ultrasound-Guided Fine-Needle Aspiration: A Case Report and Review of Literature.

    PubMed

    Collins, Katrina; Buckley, Tinera; Anderson, Kevin; Karasik, Michael; Ligato, Saverio

    2017-01-01

    Perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare mesenchymal tumors and to our knowledge, only 17 cases have been reported in the English literature to date. We report our experience with a new case of primary pancreatic PEComa diagnosed preoperatively by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) complemented by tissue cell block and immunohistochemistry. The patient was a 54-year-old female whose chief complaint was intermittent severe right upper quadrant abdominal pain. Computed-tomography (CT) imaging revealed a mass between the head and the body of the pancreas. EUS-FNA smear preparation was obtained but was nondiagnostic. However, examination of the tissue cell block showed sheets of epithelioid cells with abundant eosinophilic cytoplasm and immunohistochemistry studies revealed positivity for both melanocytic (HMB-45 and Melan-A) and smooth muscle markers (actin and desmin). A diagnosis of PEComa was made and an uncomplicated middle pancreatectomy was performed. Our case and review of the literature demonstrates that EUS-FNA complemented with tissue cell block increases cellular yield, improved preoperative diagnostic accuracy, and may assist the surgeon in planning conservative surgical management. Diagn. Cytopathol. 2017;45:59-65. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope.

    PubMed

    Binmoeller, K F; Brand, B; Thul, R; Rathod, V; Soehendra, N

    1998-05-01

    A new mechanical sector scanning echoendoscope designed for EUS-guided, fine-needle aspiration biopsy (FNAB) was prospectively evaluated. The technical feasibility, safety, and histocytologic FNAB results are reported. Eighty-six patients underwent 106 FNAB procedures. The new echoendoscope has a 2.8 mm accessory channel and an elevator. Target sites: pancreas 58, lymph nodes 43, and miscellaneous lesions 5. Lesions were punctured with a 0.7 mm needle and submitted for cytologic and histologic examination. Definitive diagnosis was by surgery or clinical follow-up. The wide scanning field (250 degrees) enabled easy sonographic orientation for FNAB. Longitudinal needle visibility was "good" in 93% and 71% of transesophageal and transgastric procedures, respectively, but were compromised during most transduodenal procedures. Needle penetration of indurated pancreatic lesions failed in two patients, and in four additional patients pancreatic sampling succeeded only after a second attempt using an automated spring-loaded device. The mean number of passes was three. Ten percent of FNAB specimens were "inadequate"; excluding these, the diagnostic accuracy rate was 97%; sensitivity for malignancy was 88.5% and specificity was 100%. EUS-guided FNAB is feasible, safe, and accurate using the new mechanical puncture echoendoscope. Needle visibility needs to be improved, particularly for transduodenal FNAB.

  4. The value of fine needle aspiration and cytologic examination of impalpable complicated breast cysts.

    PubMed

    Tez, Selda; Dener, Cenap; Köktener, Aslý; Caydere, Muzaffer; Tez, Mesut

    2008-01-01

    The purpose of the study was to evaluate the utility of fine needle aspiration--FNA and cytologic analysis of impalpable complicated breast cysts. We rewieved the imaging findings, aspiration, cytology and biopsy results and followup imaging findings of 246 complicated cysts in 166 women retrospectively. FNA was performed in 169 out of the 246 complicated cysts. Thirtyone lesions were followed-up with US. Surgical biopsy was performed from five lesions. No malignant cells (137 cysts), insufficient cellular material (17 cysts), atypical cells (4 cysts) were seen in cytological examination of the aspirates. None of these lesions were found to represent malignancy at the time of surgical excision and during follow-up. Impalpable complicated breast cysts may be classified as probably benign and can be managed with follow-up imaging studies instead of intervention. Routine cytologic examination is unnecessary if the fluid is not bloody (Tab. 2, Ref. 18). Full Text (Free, PDF) www.bmj.sk.

  5. Endoscopic ultrasound cytologic brushing vs endoscopic ultrasound: fine needle aspiration for cytological diagnosis of cystic pancreatic lesions. A multicenter, randomized open-label trial.

    PubMed

    Lariño-Noia, José; de la Iglesia, Daniel; Iglesias-García, Julio; Macías, Manuel; López Martín, Aurelio; Legaz, María Luisa; Vila, Juan; Reyes, Antonio; Abdulkader, Ihab; Domínguez-Muñoz, J Enrique

    2018-04-24

    the incidence of cystic pancreatic lesions (CPL) in the asymptomatic population is increasing. Achieving a preoperative diagnosis of CPL still remains a challenge. to evaluate the diagnostic accuracy of the cytological diagnosis of CPL from samples obtained by cytology brush versus standard endoscopic ultrasound fine needle aspiration (EUS-FNA). a multicenter, randomized, open-label trial was performed of EUS-cytology brush (EUS-EB) versus EUS-FNA for the cytological diagnosis of CPL. Patients that underwent EUS-FNA with a CPL > 15 mm were included and randomized into two groups: group I, EUS-EB; group II, EUS-FNA. The final diagnosis was based on the histological evaluation of surgical specimens and clinical parameters, imaging and a five year follow-up in non-operated patients. The main outcome was the diagnostic accuracy of both methods. Secondary outcomes were the diagnostic adequacy of specimens and the rate of adverse events. Data were compared using the Chi-squared test. An intention to treat (ITT) and per-protocol (PP) analysis were performed. sixty-five patients were included in the study, 31 in group I and 34 in group II. Three patients initially randomized to group I were changed to group II as it was impossible to obtain a sample using the brush. The mean size of the CPL was 28.2 mm (range 16-60 mm). The diagnostic accuracy of EUS-EB was not superior to EUS-FNA, neither in the ITT nor the PP analysis (44.8% vs 41.1%, p = 0.77 and 38.4% vs 45.9%, p = 0.55). EUS-EB does not improve the diagnostic accuracy of CPL in comparison with EUS-FNA.

  6. Rapid detection of metastatic melanoma in lymph nodes using proton magnetic resonance spectroscopy of fine needle aspiration biopsy specimens.

    PubMed

    Lean, Cynthia L; Bourne, Roger; Thompson, John F; Scolyer, Richard A; Stretch, Jonathan; Li, Ling-Xi Lawrence; Russell, Peter; Mountford, Carolyn

    2003-06-01

    Accurate staging of patients with primary cutaneous melanoma includes assessment of regional lymph nodes for the presence of micrometastatic disease. Sentinel lymph node biopsy is highly accurate but is an invasive surgical procedure with a 5-10% complication rate, and requires labour-intensive and expensive histological examination to identify disease. A rapid, accurate and cost-effective non-surgical technique able to detect micrometastatic deposits of melanoma in regional lymph nodes would be of great benefit. Fine needle aspiration biopsies and tissue specimens were obtained from lymph nodes from 18 patients undergoing node resection for metastatic melanoma and five patients undergoing radical retropubic prostatectomy. One-dimensional proton magnetic resonance spectroscopy was undertaken at 360 MHz (8.5 T). Lymph nodes were cut into 3 mm thick slices and embedded. Four sequential 5 microm tissue sections were cut from each block and stained, with haematoxylin and eosin, for S100 protein, for HMB45, and again with haematoxylin and eosin, respectively. Proton magnetic resonance spectroscopy distinguished between benign and malignant lymph node tissue (P < 0.001, separate t-test) and benign and malignant lymph node fine needle aspiration biopsy (P < 0.012) based on the ratio of the integrals of resonances from lipid/other metabolites (1.8-2.5 p.p.m. region) and 'choline' (3.1-3.3 p.p.m. region). In conclusion, one-dimensional proton magnetic resonance spectroscopy on a simple fine needle aspiration biopsy can distinguish lymph nodes containing metastatic melanoma from uninvolved nodes, providing a rapid, accurate and cost-effective non-surgical technique to assess regional lymph nodes in patients with melanoma.

  7. Unusual cases of metastases to the breast. A report of 17 cases diagnosed by fine needle aspiration.

    PubMed

    David, Odile; Gattuso, Paolo; Razan, Wafai; Moroz, Krzysztof; Dhurandhar, Nina

    2002-01-01

    Although nonmammary tumors metastatic to the breast are relatively uncommon, a correct diagnosis is essential to appropriate management. Radiologically these lesions are single, round, discrete lesions without the spiculations of primary malignancies. Fine needle aspiration biopsy (FNAB) may provide a definitive diagnosis, thereby sparing patients unnecessary surgery. Seventeen cases of nonmammary malignancies diagnosed by fine needle aspiration of the breast were identified in the cytopathology files at three different institutions from 1989 to 1999. Three of the cases are of particular interest, including a mucoepidermoid carcinoma of salivary gland origin and a small cell undifferentiated carcinoma of rectal origin, neither of which has been reported in the literature previously. The third case was a male with a breast mass that was originally thought to be primary based on clinical, cytologic and immunocytochemical features but subsequently was determined to be a metastasis from the lung. Virtually any malignancy may metastasize to the breast. FNAB is the best approach to the diagnosis of tumors that either clinically or radiographically are not typical of primary breast tumors. Extramammary neoplasms metastatic to the breast may be definitively diagnosed by FNAB, resulting in the most appropriate as well as cost-effective patient management.

  8. Fine needle aspiration cytology of subcutaneous cysticercosis of the breast. Case report and pathogenic discussion.

    PubMed

    Vuong, P N

    1989-01-01

    A case of subcutaneous cysticercosis of the breast diagnosed by fine needle aspiration cytology is reported. The cytologic preparations showed the presence of many inflammatory cells mixed with spiked spherules resembling the rambutan tropical fruit. These spherules arose from the degenerated integument of the parasite found in the histologically excised cyst. They are suggestive of the presence of an encysted flat worm, but are not specific for cysticercosis, whose identification is based on the study of the cephalic extremity of the parasite.

  9. Ultrasound-Guided Percutaneous Thyroid Nodule Core Biopsy: Clinical Utility in Patients with Prior Nondiagnostic Fine-Needle Aspirate

    PubMed Central

    Vij, Abhinav; Seale, Melanie K.; Desai, Gaurav; Halpern, Elkan; Faquin, William C.; Parangi, Sareh; Hahn, Peter F.; Daniels, Gilbert H.

    2012-01-01

    Background Five percent to 20% of thyroid nodule fine-needle aspiration (FNA) samples are nondiagnostic. The objective of this study was to determine whether a combination of FNA and core biopsy (CFNACB) would yield a higher proportion of diagnostic readings compared with FNA alone in patients with a history of one or more prior nondiagnostic FNA readings. Methods We conducted a retrospective study of 90 core biopsies (CBs) performed in 82 subjects (55 women and 27 men) between 2006 and 2008 in an outpatient clinic. Results CFNACB yielded a diagnostic reading in 87%. The diagnostic reading yield of the CB component of CFNACB was significantly superior to the concurrent FNA component, with CB yielding a diagnosis in 77% of cases and FNA yielding a diagnosis in 47% (p<0.0001). The combination of CB and FNA had a higher diagnostic reading yield than either alone. In 69 nodules that had only one prior nondiagnostic FNA, CB was diagnostic in 74%, FNA was diagnostic in 52%, CFNACB was diagnostic in 87%, and CB performed significantly better than FNA (p=0.0135). In 21 nodules with two or more prior nondiagnostic FNAs, CFNACB and CB were diagnostic in 86%, FNA was diagnostic in 29%, and CB was significantly better than FNA (p=0.0005). Clinical, ultrasound, or histopathologic follow-up was available for 81% (73/90) of the CFNACB procedures. No subject with a benign CFNACB reading was diagnosed with thyroid malignancy in the follow-up period (range 4–37 months, mean 18 months), although one subject had minimal increase in nodule size and was awaiting repeat sonography at study conclusion. Conclusion Thyroid nodule CFNACB is safe and clinically useful in selected patients when a prior FNA reading is nondiagnostic. CFNACB is superior to either CB or FNA alone. CFNACB should be strongly considered as an alternative to surgery in individuals with two prior nondiagnostic FNAs. PMID:22304390

  10. Three-dimensional cytomorphology in fine needle aspiration biopsy of medullary thyroid carcinoma.

    PubMed

    Chang, T C; Lai, S M; Wen, C Y; Hsiao, Y L; Huang, S H

    2001-01-01

    To elucidate three-dimensional (3-D) cytomorphology in fine needle aspiration biopsy (FNAB) of medullary thyroid carcinoma (MTC). ENAB was performed on tumors from five patients with MTC. The aspirate was stained and observed under a light microscope (LM). The aspirate was also fixed, dehydrated, critical point dried, spattered with gold ions and observed with a scanning electron microscope (SEM). For transmission electron microscopy (TEM), the specimen was fixed, dehydrated, embedded in an Epon mixture, cut with an ultramicrotome, mounted on copper grids, electron doubly stained with uranium acetate and lead citrate, and observed with TEM. Findings under SEM were correlated with those under LM and TEM. Under SEM, 3-D cytomorphology of MTC displayed a disorganized cellular arrangement with indistinct cell borders in three cases. The cell surface was uneven and had granular protrusions that corresponded to secretory granules observed under TEM. In one case with multiple endocrine neoplasia type IIB, there were abundant granules on the cell surface. In one case of sporadic MTC with multinucleated tumor giant cells and small cells, granular protrusions also were noted on the cell surface. Granular protrusion was a characteristic finding in FNAB of MTC tinder SEM and might be helpful in the differential diagnosis.

  11. Diagnostic accuracy of fine-needle aspiration cytology in Warthin tumors.

    PubMed

    Veder, Laura L; Kerrebijn, Jeroen D F; Smedts, Frank M; den Bakker, Michael A

    2010-12-01

    Our aim was to evaluate the diagnostic accuracy of fine-needle aspiration cytology (FNAC) for Warthin tumors of the parotid gland. All cytologic diagnoses of Warthin tumor between 1990 and 2007 were correlated with available histology. In addition, our results were compared to current literature. In 310 cases, Warthin tumor was diagnosed by FNAC. In 133 cases, (43%) both cytology and histology were available. In 127 of these 133 cases (95.5%), the diagnosis Warthin tumor was confirmed by histology. In 4 cases (3%), a benign lesion was diagnosed and 2 (1.5%) revealed a malignant lesion. On review, those cytologic diagnoses were not certain. In the literature, 11 missed malignancies (5.4%) in 202 cases were reported. The diagnostic accuracy of FNAC for the diagnosis of Warthin tumor is high and the percentage of missed malignant tumors is very low. Our results imply that a cytologic diagnosis of Warthin tumor may justify conservative treatment.

  12. Cystic lesions of the salivary glands: cytologic features in fine-needle aspiration biopsies.

    PubMed

    Layfield, Lester J; Gopez, Evelyn V

    2002-10-01

    A variety of neoplastic and nonneoplastic lesions of the salivary glands have a predominantly cystic architecture. Fine-needle aspirates of these lesions yield watery or mucoid material, frequently of low cellularity. Such aspirates may be obtained from mucus retention cysts, lymphoepithelial cysts, cystadenomas, Warthin's tumors, cystic pleomorphic adenomas, low-grade mucoepidermoid carcinomas, cystadenocarcinomas, and examples of polycystic disease of the parotid gland. The cellular component within the fluid obtained from these lesions may be exceedingly scant or absent, making cytologic diagnosis difficult and, at times, impossible. We studied a series of 56 cystic lesions of the salivary glands, including 38 Warthin's tumors, 6 benign cysts, 2 lymphoepithelial cysts, 5 low-grade mucoepidermoid carcinomas, 1 cystic pleomorphic adenoma, 2 cystadenomas, and 2 cystadenocarcinomas. Careful attention to the cellular elements present often allowed definitive cytologic diagnosis, with an overall accuracy rate of 84%. The presence of atypical squamous metaplasia in oncocytic lesions was a significant cause of false-positive diagnoses of carcinoma (4 cases, 7%). Aspirates of low-grade mucoepidermoid carcinoma may contain no epithelial cells and result in false-negative diagnoses (1 case, 2%). Copyright 2002 Wiley-Liss, Inc.

  13. Fine-needle aspiration cytology of malignant hemangiopericytomas with ultrastructural and flow cytometric analyses.

    PubMed

    Geisinger, K R; Silverman, J F; Cappellari, J O; Dabbs, D J

    1990-07-01

    A hemangiopericytoma (HPC) is an uncommon soft-tissue neoplasm that may arise in many body sites. The cytologic features of fine-needle aspirates (FNAs) of HPCs have only rarely been described in the literature. We examined FNAs of malignant HPCs from the head and neck region (three) and the retroperitoneum (one) in four adults (aged 38 to 83 years). All four FNAs yielded cellular specimens that consisted of uninuclear tumor cells with high nuclear-cytoplasmic ratios. The cytomorphological spectrum included nuclei that were oval to elongate and had very finely granular, evenly distributed chromatin with one or two small but distinct nucleoli. Hemangiopericytomas yield aspirates that may be considered malignant and may suggest sarcoma. Histologically, all four neoplasms manifested high mitotic activity. The ultrastructural features of all four tumors were supportive of the diagnosis of HPC. Although a specific primary diagnosis of HPC on FNA of a soft-tissue mass is unlikely, cytologic analysis may allow diagnosis of recurrent or metastatic HPC. We were able to perform flow cytometric determinations of tumor DNA content on three of the resected neoplasms. In two, an aneuploid pattern was found, including the neoplasm with the most marked pleomorphism in the FNA. The third was diploid.

  14. Success rate of repeated fine needle aspiration biopsy of clinically suspicious thyroid nodules.

    PubMed

    Nagarajah, J; Farahati, J; Görges, R; Grabellus, F; Bockisch, A; Sheu-Grabellus, S-Y

    2012-01-01

    In this study we evaluated the success rate of double fine needle aspiration biopsy (FNAB) of clinically suspicious thyroid nodules in one session. The success rate of FNAB in clinical setting is quite low. There were several attempts made to improve the success rate of this method. It is anticipated that a double FNAB in one session would increase the success rate of FNAB. 176 consecutive patients (130 women, 46 men; mean age 56 years ± 11) with at least one clinically suspicious nodule were included in this study. Each individual nodule was biopsied twice (20G- and 21G-needle). In 33 patients, two suspicious nodules were biopsied, accounting for a total of 209 biopsied thyroid nodules. To evaluate the success rate the number of cell formations and the total number of cells in each cell formation were counted. The biopsy with the 20G needle provided in mean 40 cell cluster with a mean of 830 cells whereas the 21G needle provided in mean 41 cell cluster with a mean of 1010 cells. With the 20G needle the success rate was 73%, with the 21G needle 78% and the combination of the both biopsies provided a success rate of 87% (p = 0.01). Based on the number of cell formations and the total number of cells, the difference between the two needle sizes was not significant (p = 0.5 for cell formations and p = 0.9 for the total number of cells, respectively). A double FNAB of suspicious thyroid nodules in one session provides a higher success rate, and a 21G needle is sufficient enough.

  15. Fine-needle aspiration cytology of mucous retention cyst of the tongue: distinction from other cystic lesions of the tongue.

    PubMed

    De Las Casas, L E; Bardales, R H

    2000-05-01

    Mucous retention cyst (MRC) is a common submucosal lesion of the oral cavity that, when deeply seated, simulates a neoplasm. This report describes the fine-needle aspiration cytology findings of a lingual MRC of complex architecture and with metaplastic epithelium. In addition, we emphasize its cytologic differential diagnosis from other benign and malignant cystic lesions of the tongue. To the best of our knowledge, this is the first report of aspiration cytology of a complex MRC of the tongue. Copyright 2000 Wiley-Liss, Inc.

  16. A preliminary result of three-dimensional microarray technology to gene analysis with endoscopic ultrasound-guided fine-needle aspiration specimens and pancreatic juices

    PubMed Central

    2010-01-01

    Background Analysis of gene expression and gene mutation may add information to be different from ordinary pathological tissue diagnosis. Since samples obtained endoscopically are very small, it is desired that more sensitive technology is developed for gene analysis. We investigated whether gene expression and gene mutation analysis by newly developed ultra-sensitive three-dimensional (3D) microarray is possible using small amount samples from endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) specimens and pancreatic juices. Methods Small amount samples from 17 EUS-FNA specimens and 16 pancreatic juices were obtained. After nucleic acid extraction, the samples were amplified with labeling and analyzed by the 3D microarray. Results The analyzable rate with the microarray was 46% (6/13) in EUS-FNA specimens of RNAlater® storage, and RNA degradations were observed in all the samples of frozen storage. In pancreatic juices, the analyzable rate was 67% (4/6) in frozen storage samples and 20% (2/10) in RNAlater® storage. EUS-FNA specimens were classified into cancer and non-cancer by gene expression analysis and K-ras codon 12 mutations were also detected using the 3D microarray. Conclusions Gene analysis from small amount samples obtained endoscopically was possible by newly developed 3D microarray technology. High quality RNA from EUS-FNA samples were obtained and remained in good condition only using RNA stabilizer. In contrast, high quality RNA from pancreatic juice samples were obtained only in frozen storage without RNA stabilizer. PMID:20416107

  17. Split sample comparison of a liquid-based method and conventional smears in thyroid fine needle aspiration.

    PubMed

    Jung, Chan-Kwon; Lee, Ahwon; Jung, Eun-Sun; Choi, Yeong-Jin; Jung, So-Lyung; Lee, Kyo-Young

    2008-01-01

    To compare the efficacy of the SurePath (SP) vs. conventional smears (CS) in fine needle aspiration (FNA) of thyroid gland lesions. A total of 193 FNA cases with thyroid nodules were studied. Samples from ultrasound-guided FNA were split to prepare CS and SP slides. The diagnostic categories of unsatisfactory, benign, atypical and malignant were compared. Galectin-3 immunostaining was performed on SP slides. Some differences were found between the cytomorphology of CS and SP. SP slides showed more increased cellularity and more clustered tissue fragments. On SP slides, nuclear detail and nucleoli were more easily detected and nuclear irregularity was very useful for the diagnosis of papillary carcinoma. SP showed a trend toward a lower proportion of atypical category. The overall sensitivity of FNA in diagnosing thyroid neoplasm was 90.9% for CS and 93.9% for SP. Most lesions (73%) diagnosed as papillary carcinoma after surgery showed positive staining of galectin-3. The SP method showed easy evaluation of cytomorphologic features and consistent specimen quality and appeared to be more useful in diagnosing the suspicious cases. Moreover, it offered the possibility of adjunctive immunocytochemistry on the same sample.

  18. Thyroid fine-needle aspiration cytology: performance data of neoplastic and malignant cases as identified from 1558 responses in the ASCP Non-GYN Assessment program thyroid fine-needle performance data.

    PubMed

    Eilers, Stan G; LaPolice, Paula; Mukunyadzi, Perkins; Kapur, Umesh; Wendel Spiczka, Amy; Shah, Ajay; Saleh, Husain; Adeniran, Adebowale; Nunez, Amberly; Balachandran, Indra; Clark, Jennifer J; Lemon, Larry

    2014-10-01

    Fine-needle aspiration of the thyroid is a common procedure, with an established role in reducing unnecessary thyroid surgery and identifying neoplasms and malignancies. The study evaluated 1558 responses in the American Society for Clinical Pathology (ASCP) Non-GYN Assessment program of aspirates of thyroid neoplasms and malignancies and placed them into the following groups: group A (target or correct interpretation), group B (incorrect interpretation as a benign thyroid nodule), group C (incorrect interpretation malignant aspirate as thyroid neoplasm), and group D (malignant diagnosis with incorrect interpretation). In clinical practice, responses in groups A, C, and D would lead to surgical excision, whereas responses in group B would not. Of a total of 1558 responses, 78.5% of the responses were in group A, 8.5% in group B, 3.75% in group C, and 9.25% in group D. By individual diagnosis, the group rates were 86.5%, 0%, 11%, and 2.5% for anaplastic thyroid carcinoma; 83%, 5.5%, 4.25%, and 7.25% for papillary thyroid carcinoma; 79%, 7%, 6%, and 8% for medullary thyroid carcinoma; 83.5% 6.75%, 0%, and 9.75% for Hürthle cell neoplasm; and 61%, 22%, 0%, and 17% for follicular neoplasm in groups A, B, C, and D respectively. Fine-needle aspiration was effective in diagnosing thyroid neoplasms and malignancies and in separating thyroid nodules into surgical and nonsurgical categories. Data from a large group of cytology professionals showed good performance; however, there is room for improvement, especially in making specific diagnoses. In particular, follicular neoplasm and follicular variant of papillary thyroid carcinoma were challenging diagnoses for participants. © 2014 The Authors. Cancer Cytopathology published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  19. Cysticercosis: Hooked by a Hooklet on Fine Needle Aspiration Cytology—A Case Report

    PubMed Central

    Sawhney, Manav; Agarwal, Shubhra

    2013-01-01

    Cysticercosis is a systemic parasitic disease caused by the larval form of cestode T. solium. It has a worldwide distribution and is potentially harmful with variable clinical manifestations. The patient most commonly presents with subcutaneous and muscle involvement in the form of nodular lesions. The other most commonly involved sites include eye, brain, bladder wall, and heart. Cysticercosis can be diagnosed on serology, and radiologically but confirmatory diagnosis is based on histopathological examination of the involved tissue biopsy specimen. Fine needle aspiration cytology is a useful low-cost outpatient procedure tool for preoperative diagnosis of cysticercosis and is absolutely essential for diagnosis of the parasitic lesions in a peripheral hospital, one like ours. PMID:24024052

  20. Technical Advances in Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition for Pancreatic Cancers: How Can We Get the Best Results with EUS-Guided Fine Needle Aspiration?

    PubMed Central

    Kedia, Prashant; Gaidhane, Monica

    2013-01-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is one of the least invasive and most effective modality in diagnosing pancreatic adenocarcinoma in solid pancreatic lesions, with a higher diagnostic accuracy than cystic tumors. EUS-FNA has been shown to detect tumors less than 3 mm, due to high spatial resolution allowing the detection of very small lesions and vascular invasion, particularly in the pancreatic head and neck, which may not be detected on transverse computed tomography. Furthermore, this minimally invasive procedure is often ideal in the endoscopic procurement of tissue in patients with unresectable tumors. While EUS-FNA has been increasingly used as a diagnostic tool, most studies have collectively looked at all primary pancreatic solid lesions, including lymphomas and pancreatic neuroendocrine neoplasms, whereas very few studies have examined the diagnostic utility of EUS-FNA of pancreatic ductal carcinoma only. As with any novel and advanced endoscopic procedure that may incorporate several practices and approaches, endoscopists have adopted diverse techniques to improve the tissue procurement practice and increase diagnostic accuracy. In this article, we present a review of literature to date and discuss currently practiced EUS-FNA technique, including indications, technical details, equipment, patient selection, and diagnostic accuracy. PMID:24143320

  1. Technical description of endoscopic ultrasonography with fine-needle aspiration for the staging of lung cancer.

    PubMed

    Kramer, Henk; van Putten, John W G; Douma, W Rob; Smidt, Alie A; van Dullemen, Hendrik M; Groen, Harry J M

    2005-02-01

    Endoscopic ultrasonography (EUS) is a novel method for staging of the mediastinum in lung cancer patients. The recent development of linear scanners enables safe and accurate fine-needle aspiration (FNA) of mediastinal and upper abdominal structures under real-time ultrasound guidance. However, various methods and equipment for mediastinal EUS-FNA are being used throughout the world, and a detailed description of the procedures is lacking. A thorough description of linear EUS-FNA is needed. A step-by-step description of the linear EUS-FNA procedure as performed in our hospital will be provided. Ultrasonographic landmarks will be shown on images. The procedure will be related to published literature, with a systematic literature search. EUS-FNA is an outpatient procedure under conscious sedation. The typical linear EUS-FNA procedure starts with examination of the retroperitoneal area. After this, systematic scanning of the mediastinum is performed at intervals of 1-2cm. Abnormalities are noted, and FNA of the abnormalities can be performed. Specimens are assessed for cellularity on-site. The entire procedure takes 45-60 min. EUS-FNA is minimally invasive, accurate, and fast. Anatomical areas can be reached that are inaccessible for cervical mediastinoscopy. EUS-FNA is useful for the staging of lung cancer or the assessment and diagnosis of abnormalities in the posterior mediastinum.

  2. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil*,**

    PubMed Central

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients. PMID:25750671

  3. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil.

    PubMed

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.

  4. Molecular Signature of Indeterminate Thyroid Lesions: Current Methods to Improve Fine Needle Aspiration Cytology (FNAC) Diagnosis

    PubMed Central

    Cantara, Silvia; Marzocchi, Carlotta; Pilli, Tania; Cardinale, Sandro; Forleo, Raffaella; Castagna, Maria Grazia; Pacini, Furio

    2017-01-01

    Fine needle aspiration cytology (FNAC) represents the gold standard for determining the nature of thyroid nodules. It is a reliable method with good sensitivity and specificity. However, indeterminate lesions remain a diagnostic challenge and researchers have contributed molecular markers to search for in cytological material to refine FNAC diagnosis and avoid unnecessary surgeries. Nowadays, several “home-made” methods as well as commercial tests are available to investigate the molecular signature of an aspirate. Moreover, other markers (i.e., microRNA, and circulating tumor cells) have been proposed to discriminate benign from malignant thyroid lesions. Here, we review the literature and provide data from our laboratory on mutational analysis of FNAC material and circulating microRNA expression obtained in the last 6 years. PMID:28383480

  5. Evolution of a rapid onsite evaluation (ROSE) service for endobronchial ultrasound guided (EBUS) fine needle aspiration (FNA) cytology in a UK Hospital: A 7 year audit.

    PubMed

    Stevenson, Tracey; Powari, Manish; Bowles, Christopher

    2018-05-13

    Endobronchial ultrasound fine needle aspiration (EBUS FNA) is a well-established procedure for the diagnosis and staging of lung cancer. We review our provision of this service at the Royal Devon and Exeter NHS Foundation Trust and the role of rapid onsite evaluation (ROSE) with the increasing demand for molecular markers in this era of personalized medicine. A review of the changes in the Endoscopy clinic over the 7 years from the introduction of EBUS at the end of 2010 until 2017 was carried out. This included the availability of material obtained for diagnosis, accurate subtyping, and molecular testing. We also assessed the success of molecular genetics DNA techniques from EBUS material versus formalin fixed paraffin embedded tissue (FFPE). A total of 1218 EBUS cases with ROSE were reported between 2011 and 2017 Percentage diagnostic rates were calculated as 83, 82, 84, 92, 93, 94, and 92 for 2011, 2012, 2013, 2014, 2015, 2016, and 2017, respectively. Availability of material for immunocytochemistry ranged from 86 to 100% over the 7 years. Molecular testing was successfully performed for EGFR in 89-100% of requested cases and ALK testing in 87-100% of requested cases. EBUS sourced material gave on average twice the amount of DNA and fewer amplicon repeats per patient compared to FFPE material. ROSE at EBUS FNA provides access to suitable material for molecular testing with increased yields in the form of needle washings for EGFR with FFPE materials for ALK and PDL1 testing. © 2018 Wiley Periodicals, Inc.

  6. Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration Cytology (SP-US-FNAC) Shortens Time for Diagnosis of Thyroid Nodules.

    PubMed

    Gu, Wei Xiang; Tan, Chuen Seng; Ho, Thomas W T

    2014-06-01

    Ultrasound-guided fine-needle aspiration cytology (US-FNAC) of thyroid nodules is an important diagnostic procedure. In most hospitals, patients are referred to radiologists for US-FNAC, but this often results in a long waiting time before results are available. Surgeon-performed US-FNAC (SP-US-FNAC) during the initial patient consultation attempts to reduce the waiting time but it is not known whether this is as accurate as radiologist-performed US-FNAC (RP-US-FNAC). The aim of this study is to compare the clinical efficiency between SP-US-FNAC and RP-US-FNAC. A retrospective study was performed on patients from the Department of General Surgery, Tan Tock Seng Hospital (TTSH) who underwent an US-FNAC from August 2011 to May 2012. All cases of SP-US-FNAC were performed by a single surgeon. This study compared the rates of positive diagnoses achieved by SP-US-FNAC and RPUS- FNAC as well as the time interval to reach a cytological diagnosis by each group. A total of 40 cases of SP-US-FNAC and 72 cases of RP-US-FNAC were included in the study. SP-US-FNAC resulted in 28 (70%) positive diagnoses and 12 (30%) nondiagnoses while RP-US-FNAC resulted in 47 (65.3%) positive diagnoses and 25 (34.7%) non-diagnoses. These results were comparable (P=0.678). The median time taken to reach a cytological diagnosis was 1 working day for SP-US-FNAC and 29.5 working days for RP-US-FNAC resulting in a shorter interval to reaching a cytological diagnosis for SP-US-FNAC (P<0.001). In the workup of thyroid nodules, SP-US-FNAC is as accurate as RP-US-FNAC but significantly reduces the time taken to reach a cytological diagnosis. This leads to greater clinical efficiency in the management of patients with thyroid nodules, which in turn leads to other benefits such as decreased patient anxiety and increased patient satisfaction.

  7. A new posterior iliac puncture/aspiration needle.

    PubMed

    Islam, Anwarul

    2016-03-25

    The needles that are currently used for obtaining bone marrow aspirate samples from the posterior ilium are typically those of 1930s vintage (eg, Klima, Salah or similar needles), which were specifically designed for sternal aspiration. These needles are not designed to obtain bone marrow aspirate samples from the posterior ilium and as a result they are unsatisfactory particularly if the patient is large or obese. A new posterior iliac puncture/aspiration needle has therefore been designed, which is particularly suited for bone marrow aspiration from the posterior ilium. The needle was tested on five cadavers and on five patients. The design and construction of the needle was found to be satisfactory and a marked improvement over the conventional sternal puncture needles particularly when large or obese patients were concerned. The new posterior iliac bone marrow aspiration needle has advantages that overcome the limitations of using a conventional sternal puncture needle to obtain marrow aspirates from the posterior ilium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Aspergillus thyroiditis: first antemortem case diagnosed by fine-needle aspiration culture in a pediatric stem cell transplant patient.

    PubMed

    Badawy, S M; Becktell, K D; Muller, W J; Schneiderman, J

    2015-12-01

    Aspergillus thyroiditis (AT) has historically been considered a postmortem diagnosis in immunocompromised patients; most have disseminated disease. This report summarizes the clinical challenge of diagnosing AT. It also highlights the value of the early use of thyroid fine-needle aspiration culture and the need for a high index of suspicion to reach the final diagnosis before disease dissemination. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Image-Directed Fine-needle Aspiration Biopsy of the Thyroid with Safety-engineered Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Palmer, Dennis J., E-mail: lyonscreek@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu

    2011-10-15

    Purpose: The purpose of the present study was to integrate safety-engineered devices into outpatient fine-needle aspiration (FNA) biopsy of the thyroid in an interventional radiology practice. Materials and Methods: The practice center is a tertiary referral center for image-directed FNA thyroid biopsies in difficult patients referred by the primary care physician, endocrinologist, or otolaryngologist. As a departmental quality of care and safety improvement program, we instituted integration of safety devices into our thyroid biopsy procedures and determined the effect on outcome (procedural pain, diagnostic biopsies, inadequate samples, complications, needlesticks to operator, and physician satisfaction) before institution of safety devices (54more » patients) and after institution of safety device implementation (56 patients). Safety devices included a patient safety technology-the mechanical aspirating syringe (reciprocating procedure device), and a health care worker safety technology (antineedlestick safety needle). Results: FNA of thyroid could be readily performed with the safety devices. Safety-engineered devices resulted in a 49% reduction in procedural pain scores (P < 0.0001), a 56% reduction in significant pain (P < 0.002), a 21% increase in operator satisfaction (P < 0.0001), and a 5% increase in diagnostic specimens (P = 0.5). No needlesticks to health care workers or patient injuries occurred during the study. Conclusions: Safety-engineered devices to improve both patient and health care worker safety can be successfully integrated into diagnostic FNA of the thyroid while maintaining outcomes and improving safety.« less

  10. Fine needle aspiration cytology of granulomatous mastitis with special emphasis on microbiologic correlation.

    PubMed

    Nemenqani, Dalal; Yaqoob, Nausheen; Hafiz, Momein

    2009-01-01

    To describe the cytomorphology of granulomatous mastitis (GM) and to evaluate the causative agents involved, proven on the basis of microbiologic culture results and polymerase chain reaction (PCR) studies. We retrospectively reviewed the inflammatory breast aspirates reported at King Abdul Aziz Specialist Hospital and Al Hada Armed Forces Hospital, Taif, Kingdom of Saudi Arabia, from January 2000 until March 2008. The pathology reports, clinical information, slides, microbiologic culture results and tuberculosis (TB)/PCR were reviewed. Cases of inflammatory carcinoma or duct ectasia were excluded. A total of 49 cases of inflammatory breast aspirates were identified, of which 15 cases were GM. The microbiologic cultures of all 15 cases were available. Six of 15 cases had positive culture for Brucella melitenses, and 2 cases were positive for TB, which was further confirmed by TB/PCR. The fungal cultures were negative in all the cases. Seven of 15 cases were classified as idiopathic GM. Fine needle aspiration cytology was found to be a useful tool in the early diagnosis of GM and its classification if performed by a pathologist as the material can be submitted for culture. The definitive diagnosis can be established by a combination of the cytomorphologic features and microbiologic studies.

  11. Use of fine needle aspirate from peripheral nerves of pure-neural leprosy for cytology and PCR to confirm the diagnosis: a pilot study.

    PubMed

    Reja, Abu Hena Hasanoor; De, Abhishek; Biswas, Supratik; Chattopadhyay, Amitabha; Chatterjee, Gobinda; Bhattacharya, Basudev; Sarda, Aarti; Aggarwal, Ishad

    2013-01-01

    The diagnosis of pure neural leprosy (PNL) remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC) coupled with Ziehl Neelsen staining (ZN staining) and Multiplex-Polymerase Chain Reaction (PCR) specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL), which may be simpler and yet reliable. The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex-PCR. Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4%) with the help of conventional acid-fast staining and 11 cases (84.6%) with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23%) cases showed specific epithelioid cells, whereas 8 (61.5%) cases showed non-specific inflammation, and 2 (15.3%) cases had no inflammatory cells. Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB) and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of PNL.

  12. Induction of parotitis by fine-needle aspiration in parotid Warthin's tumor.

    PubMed

    Suzuki, Kensuke; Iwai, Hiroshi; Kaneko, Toshihiko; Sakaguchi, Mariko; Hoshino, Shoichi; Inaba, Muneo

    2009-08-01

    To estimate parotitis caused by fine-needle aspiration (FNA) in parotid Warthin tumor. Case series with chart review. Hospital records were reviewed for 104 parotid tumors (103 patients) including 35 Warthin tumors, which underwent FNA within our department. Three patients with four Warthin tumors among them noticed parotid pain, swelling, and abscess formation as a consequence of acute parotitis after FNA. Examinations of the materials obtained from tumor puncture or drainage before the start of antibiotic therapy showed no bacterial association in any patient. Two of the patients with Warthin tumor underwent parotidectomy, and the surgical specimens indicated histopathological changes with necrosis, abscess, granuloma, and the infiltration of inflammatory cells including Langhans-type multinucleated giant cells. It is conceivable that Warthin tumor bears the characteristics of inflammation induced by the FNA procedure without any relation to infection. Therefore, it may be better to avoid routine FNA and give priority to diagnostic imagings over FNA in the diagnosis of tumors strongly suspected as Warthin tumor.

  13. The role of fine needle aspiration cytology in medical-surgical missions.

    PubMed

    Reyes, Cesar V; Reyes, Elisa A

    2009-01-01

    To relate a 6-year, short-term experience of utilizing fine needle aspiration cytology (FNAC) during medical-surgical missions in the impoverished areas of the Philippines. FNAC is a simple, accurate, fast and economical procedure and requires the simplest devices to implement. During medical-surgical missions to the poorest areas in the Third World countries, where there is almost complete lack of tissue processing and frozen section evaluation, and scarcity of laboratory testing, FNAC becomes a practical technique to use. FNAC in these situations plays an important role as an alternative diagnostic modality to surgery. Our week-long mission experience for 6 different years of successful application of FNAC is described. While the mission volunteers have gained extremely rewarding experience in these limited mission works, FNAC has proven to be a very useful adjunct in the delivery of short-term health care during medical-surgical treatment even in a less-than-ideal setting.

  14. Painless giant cell thyroiditis diagnosed by fine needle aspiration and associated with intense thyroidal uptake of gallium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanders, L.R.; Moreno, A.J.; Pittman, D.L.

    1986-05-01

    A 52-year-old woman presented with fever, goiter, and no evidence of pain or tenderness in the thyroid. A diagnosis of silent thyroiditis was made after obtaining evidence of biochemical thyrotoxicosis, intense gallium-67 citrate thyroidal localization, and cytologic thyroiditis. Fine needle aspiration biopsy of the thyroid revealed numerous giant cells in all areas of the thyroid, typical of subacute thyroiditis. This is believed to be the first time painless thyroiditis is reported with the classic cytologic feature of painful subacute thyroiditis.

  15. Fine needle aspiration cytology of breast cancer in women aged 70 years and older.

    PubMed

    Tse, Gary M K; Somali, Anjali; Chan, Anthony W H; Chaiwun, Benjaporn; Lui, Philip C W; Moriya, Takuya; Hwang, Jacqueline S G; Chan, Norman H L; Tan, Puay Hoon

    2008-10-01

    Elderly breast cancers are associated with a more favourable biological marker profile and higher proportion of specific subtypes, some of which are of low histological grade. We reviewed the fine needle aspiration cytology (FNAC) to assess the cytological characteristics and any clues to assist in the diagnosis. The aspirates of 140 cancers of various histological types and grades and 39 benign lesions were evaluated for 13 cytological parameters including cellularity of the direct and cytospin smears, epithelial cell clusters, cellular atypism, cytoplasmic features, vacuoles, mitotic figures, presence of myoepithelial cells, single background epithelial cells, the presence of naked nuclei, stromal fragments and necrosis. We found that the presence of background single epithelial cells, atypism of such cells, absence of benign appearing epithelial fragments, nuclear atypism of the epithelial cells within the fragments, presence of moderate amount of cytoplasm of these cells, absence of myoepithelial cells within the cluster, and absence of bipolar nuclei in the background have a strong association with malignancy. Scoring only the presence of single cells in the background, single cell atypism and the absence of bipolar nuclei in a scoring system can differentiate between benign and malignant aspirates with high (>90%) sensitivity and specificity. Assessing the presence of single cells in the background, single cell atypism and the absence of bipolar nuclei facilitates identification of malignancy in the aspiration of breast lesions from elderly patients.

  16. Two Cases of Lethal Complications Following Ultrasound-Guided Percutaneous Fine-Needle Biopsy of the Liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drinkovic, Ivan; Brkljacic, Boris

    1996-09-15

    Two cases with lethal complications are reported among 1750 ultrasound (US)-guided percutaneous fine-needle liver biopsies performed in our department. The first patient had angiosarcoma of the liver which was not suspected after computed tomography (CT) and US studies had been performed. The other patient had hepatocellular carcinoma in advanced hepatic cirrhosis. Death was due to bleeding in both cases. Pre-procedure laboratory tests did not reveal the existence of major bleeding disorders in either case. Normal liver tissue was interposed in the needle track between the liver capsule and the lesions which were targeted.

  17. Fine-needle aspiration cytology of postirradiation sarcomas, including angiosarcoma, with immunocytochemical confirmation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silverman, J.F.; Lannin, D.L.; Larkin, E.W.

    1989-01-01

    Postirradiation sarcomas are an unusual but well-recognized late effect of cancer therapy. In this article, a fine-needle aspiration (FNA) series of four cases is presented. There were three female patients and one male patient, with an age range of 28-55 yr (mean, 41). Two of the patients were irradiated for uterine cervical carcinoma while the other two received irradiation for malignant lymphoma. The time interval to the development of the postirradiation sarcoma ranged from 10 to greater than 20 yr. There were a postirradiation synovial sarcoma of the buttock region, malignant fibrous histiocytoma of the bone (femur), and rhabdomyosarcoma andmore » angiosarcoma of the retroperitoneum. A spectrum of cytologic findings was encountered, reflecting the specific types of sarcomas. Immunocytochemical studies performed on the aspirated material from the angiosarcoma demonstrated the utility of immunoperoxidase stains for ULEX europaeus agglutinin-1 (UEA-1) and, to a lesser degree, factor VIII-related antigen antibody, confirming the vascular nature of this malignancy. The FNA findings from all four cases demonstrated cytologic features that allowed recognition of this unusual complication of irradiation treatment. This article confirms the utility of FNA cytology in following patients with previous malignancies and differentiating a postirradiation sarcoma from recurrent carcinoma.« less

  18. Thyroid Nodule Classification in Ultrasound Images by Fine-Tuning Deep Convolutional Neural Network.

    PubMed

    Chi, Jianning; Walia, Ekta; Babyn, Paul; Wang, Jimmy; Groot, Gary; Eramian, Mark

    2017-08-01

    With many thyroid nodules being incidentally detected, it is important to identify as many malignant nodules as possible while excluding those that are highly likely to be benign from fine needle aspiration (FNA) biopsies or surgeries. This paper presents a computer-aided diagnosis (CAD) system for classifying thyroid nodules in ultrasound images. We use deep learning approach to extract features from thyroid ultrasound images. Ultrasound images are pre-processed to calibrate their scale and remove the artifacts. A pre-trained GoogLeNet model is then fine-tuned using the pre-processed image samples which leads to superior feature extraction. The extracted features of the thyroid ultrasound images are sent to a Cost-sensitive Random Forest classifier to classify the images into "malignant" and "benign" cases. The experimental results show the proposed fine-tuned GoogLeNet model achieves excellent classification performance, attaining 98.29% classification accuracy, 99.10% sensitivity and 93.90% specificity for the images in an open access database (Pedraza et al. 16), while 96.34% classification accuracy, 86% sensitivity and 99% specificity for the images in our local health region database.

  19. Role of fine needle aspiration cytology and cell block in diagnosis of scar endometriosis: A case report

    PubMed Central

    Dash, Sashibhusan; Panda, Sasmita; Rout, Niranjan; Samantaray, Sagarika

    2015-01-01

    Presence of endometrial glands and stroma in places other than the uterus is called endometriosis. It can be pelvic or extra-pelvic. Abdominal scar endometriosis is an extra-pelvic endometriosis that can occur after surgery involving the uterus. Post-caesarean section, scar endometriosis is a rare event. The diagnosis is frequently made only after excision of disease tissue. We present a case of post-caesarean section abdominal scar endometriosis presenting as a tumor on the abdominal wall, which was diagnosed by fine needle aspiration cytology and confirmed by cell block preparation. PMID:25948955

  20. Clinical utility of routine pre-operative axillary ultrasound and fine needle aspiration cytology in patient selection for sentinel lymph node biopsy.

    PubMed

    Rattay, T; Muttalib, M; Khalifa, E; Duncan, A; Parker, S J

    2012-04-01

    In patients with operable breast cancer, pre-operative evaluation of the axilla may be of use in the selection of appropriate axillary surgery. Pre-operative axillary ultrasound (US) and fine needle aspiration cytology (FNAC) assessments have become routine practice in many breast units, although the evidence base is still gathering. This study assessed the clinical utility of US+/-FNAC in patient selection for either axillary node clearance (ANC) or sentinel lymph node biopsy (SLNB) in patients undergoing surgery for operable breast cancer. Over a two-year period, 348 patients with a clinically negative axilla underwent axillary US. 67 patients with suspicious nodes on US also underwent FNAC. The sensitivity and specificity of axillary investigations to determine nodal involvement were 56% (confidence interval: 47-64%) and 90% (84-93%) for US alone, and 76% (61-87%) and 100% (65-100%) for FNAC combined with US, respectively. With a positive US, the post-test probability was 78%. A negative US carried a post-test probability of 25%. When FNAC was positive, the post-test probability was greater than unity. A negative FNAC yielded a post-test probability of 52%. All patients with positive FNAC and most patients with suspicious US were listed for axillary node clearance (ANC) after consideration at the multi-disciplinary team (MDT) meeting. With pre-operative axillary US+/-FNAC, 20% of patients were saved a potential second axillary procedure, facilitating a reduction in the overall re-operation rate to 12%. In this study, a positive pre-operative US+/-FNAC directs patients towards ANC. When the result is negative, other clinico-pathological factors need to be taken into account in the selection of the appropriate axillary procedure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a concise review.

    PubMed

    Aziz, Fahad

    2012-09-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) offers a minimally invasive alternative to mediastinoscopy with additional access to the hilar nodes, a better safety profile, and it removes the costs and hazards of theatre time and general anesthesia with comparable sensitivity, although the negative predictive value of mediastinoscopy (and sample size) is greater. EBUS- TBNA also obtains larger samples than conventional TBNA, has superior performance and theoretically is safer, allowing real-time sampling under direct vision. It can also have predictive value both in sonographic appearance of the nodes and histological characteristics. EBUS-TBNA is therefore indicated for NSCLC staging, diagnosis of lung cancer when there is no endobronchial lesion, and diagnosis of both benign (especially tuberculosis and sarcoidosis) and malignant mediastinal lesions. The procedure is different than for flexible bronchoscopy, takes longer, and requires more training. EBUS-TBNA is more expensive than conventional TBNA but can save costs by reducing the number of more costly mediastinoscopies. In the future, endobronchial ultrasound may have applications in airways disease and pulmonary vascular disease.

  2. Tracheobronchial puncture-site nodular reaction (TPNR) following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): Systematic review of case reports.

    PubMed

    Madan, Karan; Tiwari, Pavan; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR) with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  3. Diagnostic Efficacy of Cell Block Immunohistochemistry, Smear Cytology, and Liquid-Based Cytology in Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Lesions: A Single-Institution Experience

    PubMed Central

    Qin, Shan-yu; Zhou, You; Li, Ping; Jiang, Hai-xing

    2014-01-01

    Background The diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) cytology varies widely depending on the treatment method of the specimens. The present study aimed to evaluate the diagnostic efficacy of cell block (CB) immunohistochemistry, smear cytology (SC), and liquid-based cytology (LBC) in patients with pancreatic lesions without consulting an on-site cytopathologist. Methods This study prospectively enrolled 72 patients with pancreatic lesions. The EUS-FNA specimens were examined by SC, LBC, and CB immunohistochemistry. The diagnostic efficacy of the 3 methods was then compared. Patients’ final diagnosis was confirmed by surgical resection specimens, diagnostic imaging, and clinical follow-up. Results Our results included 60 malignant and 12 benign pancreatic lesions. The diagnostic sensitivity (90%), negative predictive value (66.7%), and accuracy (91.7%) of CB immunohistochemistry were significantly higher than those of SC (70.0%, 30.0%, and 75.0%, respectively) and LBC (73.3%, 31.6%, and 77.8%, respectively) (all P<0.05). The combination of CB and SC, or CB and LBC, did not significantly increase the efficacy compared to CB immunohistochemistry alone. Conclusion Our findings suggest that in the absence of an on-site cytopathologist, CB immunohistochemistry on EUS-FNA specimens offers a higher diagnostic efficacy in patients with pancreatic lesions than does SC and LBC. PMID:25259861

  4. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.

    1996-09-15

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnosticmore » tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles.« less

  5. Atypia in fine needle aspirates of breast lesions.

    PubMed

    Tran, Phuong Viet The; Lui, Philip C W; Yu, Alex M C; Vinh, Pham The; Chau, Helen H L; Ma, Tony K F; Tan, Puay-Hoon; Tse, Gary M

    2010-07-01

    The atypical category is controversial in fine needle aspiration cytology (FNAC) of the breast; most are benign, but a significant number are malignant. To date, no morphological criterion has been found to be consistent in predicting malignancy. To evaluate specific cytological parameters and assess their usefulness in predicting histological outcome in a cohort of atypical breast FNAC, in order to establish a set of objective criteria in defining 'high risk' atypical breast FNAC. A retrospective review of 98 cases of atypical breast FNAC with histological correlation was undertaken. The cytological preparations were evaluated for cellularity, percentage of epithelial cell cluster and single epithelial cells, nuclear atypia, nucleus:cytoplasm ratio, percentage of bipolar nuclei, and the presence of stromal fragments, histiocytes and necrosis. 66 of 98 cases (67.35%) showed benign histology and 32 cases (32.65%) showed malignant histology. Compared with the malignant group, the benign group had significantly lower patient age (p=0.05), higher bipolar nuclei (p<0.0001), less degree of nuclear pleomorphism (p<0.0001), lower nucleus:cytoplasm ratio (p<0.0001), lower cellularity (p=0.05) and less necrosis (p<0.001). There was no difference in the percentage of epithelial clusters and single cells, or the presence of stromal fragments and histiocytes. The presence of nuclear pleomorphism, high nucleus:cytoplasm ratio, epithelial cell atypia, low number of bipolar nuclei and necrosis are useful parameters to predict malignancy in atypical FNAC of the breast. Assessment of these factors in atypical FNAC may be helpful in predicting cancer risk and subsequent management decision making.

  6. When Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?

    PubMed Central

    Schmidt, Robert L.; Walker, Brandon S.; Cohen, Michael B.

    2015-01-01

    Background Rapid on-site evaluation (ROSE) can improve adequacy rates of fine-needle aspiration biopsy (FNAB) but increases operational costs. The performance of ROSE relative to fixed sampling depends on many factors. It is not clear when ROSE is less costly than sampling with a fixed number of needle passes. The objective of this study was to determine the conditions under which ROSE is less costly than fixed sampling. Methods Cost comparison of sampling with and without ROSE using mathematical modeling. Models were based on a societal perspective and used a mechanistic, micro-costing approach. Sampling policies (ROSE, fixed) were compared using the difference in total expected costs per case. Scenarios were based on procedure complexity (palpation-guided or image-guided), adequacy rates (low, high) and sampling protocols (stopping criteria for ROSE and fixed sampling). One-way, probabilistic, and scenario-based sensitivity analysis was performed to determine which variables had the greatest influence on the cost difference. Results ROSE is favored relative to fixed sampling under the following conditions: (1) the cytologist is accurate, (2) the total variable cost ($/hr) is low, (3) fixed costs ($/procedure) are high, (4) the setup time is long, (5) the time between needle passes for ROSE is low, (6) when the per-pass adequacy rate is low, and (7) ROSE stops after observing one adequate sample. The model is most sensitive to variation in the fixed cost, the per-pass adequacy rate, and the time per needle pass with ROSE. Conclusions Mathematical modeling can be used to predict the difference in cost between sampling with and without ROSE. PMID:26317785

  7. CT-guided percutaneous fine-needle aspiration biopsy of the inferior vena cava wall: a posterior coaxial approach.

    PubMed

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L

    2010-02-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  8. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less

  9. Diagnostic accuracy of fine-needle aspiration cytology of thyroid gland lesions: A study of 200 cases in Himalayan belt.

    PubMed

    Sharma, Reetika; Verma, Neelam; Kaushal, Vijay; Sharma, Dev Raj; Sharma, Dhruv

    2017-01-01

    The study is undertaken to correlate the fine-needle aspiration cytology (FNAC) findings with histopathology in a spectrum of thyroid lesions and to find the diagnostic accuracy of fine-needle aspiration (FNA) so that unnecessary thyroidectomies can be avoided in benign lesions. This study was carried out over the period of 1-year (May 1, 2012-April, 30 2013). FNA specimens obtained from 200 patients were analyzed. Of these, only 40 patients underwent surgery and their thyroid specimens were subjected to histopathological examination. The age of the patients ranged from 9 to 82 years with mean age being 43 years. There was female preponderance, with male to female ratio being 1:7. On cytology out of 200 cases, 148 (74%) were benign, 25 (12.5%) were malignant, 16 (8%) were indeterminate, and 11 (5.5%) were nondiagnostic. Only 40 patients underwent surgery. On histopathology, 21 (52.5%) cases were benign and 19 (47.5%) were malignant. The statistical analysis of cytohistological correlation for both benign and malignant lesions revealed sensitivity, specificity, and diagnostic accuracy of 84%, 100% and 90%, respectively. FNAC is a minimally invasive, highly accurate and cost-effective procedure for the assessment of patients with thyroid lesions and has high -sensitivity and specificity. It acts as a good screening test and avoids unnecessary thyroidectomies.

  10. Acquired myospherulosis secondary to gluteal augmentation on fine needle aspiration cytology: A diagnostic challenge.

    PubMed

    Alperstein, Susan; Dilcher, Thomas; Viswanathan, Kartik; Rao, Rema A; Siddiqui, Momin T; Giorgadze, Tamara

    2018-05-01

    A 30-year-old female presented with a three-month history of a multilocular cystic lesion over the lumbosacral spine. Fine-needle aspiration biopsy (FNA) of the lesion was performed at an outside institution, and a cytologic diagnosis, suspicious for chordoma, was rendered. The patient presented for surgical consultation at our institution. Repeat FNA demonstrated an unusual fat-like material. Upon further inquiry, the patient provided a recent history of gluteal contour improvement with fibroadipose tissue implants. A diagnosis of myospherulosis was made with a concurrent surgical pathology correlation. No evidence of chordoma was identified. To date, this is the first reported case of acquired myospherulosis in the context of gluteal contour enhancement and represents an important diagnostic pitfall to consider on cytology preparations. © 2017 Wiley Periodicals, Inc.

  11. Initiation and Characterization of Small Cell Lung Cancer Patient-Derived Xenografts from Ultrasound-Guided Transbronchial Needle Aspirates

    PubMed Central

    Anderson, Wade C.; Boyd, Michael B.; Aguilar, Jorge; Pickell, Brett; Laysang, Amy; Pysz, Marybeth A.; Bheddah, Sheila; Ramoth, Johanna; Slingerland, Brian C.; Dylla, Scott J.; Rubio, Edmundo R.

    2015-01-01

    Small cell lung cancer (SCLC) is a devastating disease with limited treatment options. Due to its early metastatic nature and rapid growth, surgical resection is rare. Standard of care treatment regimens remain largely unchanged since the 1980’s, and five-year survival lingers near 5%. Patient-derived xenograft (PDX) models have been established for other tumor types, amplifying material for research and serving as models for preclinical experimentation; however, limited availability of primary tissue has curtailed development of these models for SCLC. The objective of this study was to establish PDX models from commonly collected fine needle aspirate biopsies of primary SCLC tumors, and to assess their utility as research models of primary SCLC tumors. These transbronchial needle aspirates efficiently engrafted as xenografts, and tumor histomorphology was similar to primary tumors. Resulting tumors were further characterized by H&E and immunohistochemistry, cryopreserved, and used to propagate tumor-bearing mice for the evaluation of standard of care chemotherapy regimens, to assess their utility as models for tumors in SCLC patients. When treated with Cisplatin and Etoposide, tumor-bearing mice responded similarly to patients from whom the tumors originated. Here, we demonstrate that PDX tumor models can be efficiently established from primary SCLC transbronchial needle aspirates, even after overnight shipping, and that resulting xenograft tumors are similar to matched primary tumors in cancer patients by both histology and chemo-sensitivity. This method enables physicians at non-research institutions to collaboratively contribute to the rapid establishment of extensive PDX collections of SCLC, enabling experimentation with clinically relevant tissues and development of improved therapies for SCLC patients. PMID:25955027

  12. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    PubMed

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  13. Fine-needle aspiration cytology of hemangiopericytoma: A report of five cases.

    PubMed

    Chhieng, D; Cohen, J M; Waisman, J; Fernandez, G; Cangiarella, J

    1999-08-25

    Hemangiopericytoma (HPC) is a relatively rare neoplasm, accounting for approximately 2.5% of all soft tissue tumors. Its histopathology has been well documented but to the authors' knowledge reports regarding its fine-needle aspiration (FNA) cytology rarely are encountered. In the current study the authors report the cytologic findings in FNA specimens from nine confirmed cases of HPC and attempt to correlate the cytologic features with the biologic outcomes. FNA was performed with or without radiologic guidance. Corresponding sections of tissue were reviewed in conjunction with the cytologic preparations. Nine FNAs were performed in 5 patients (3 men and 2 women) with an age range of 38-77 years (mean, 56 years). Two lesions were primary soft tissue lesions arising in the lower extremities; seven were recurrent or metastatic lesions from bone (one lesion), kidney (one lesion), pelvic fossa (one lesion), lower extremities (two lesions), trunk (one lesion), and breast (one lesion). All aspirates were cellular and were comprised of single and tightly packed clusters of oval to spindle-shaped cells aggregated around branched capillaries. Basement membrane material was observed in 6 cases (67%). The nuclei were uniform and oval, with finely granular chromatin and inconspicuous nucleoli in all cases except one. No mitotic figures or areas of necrosis were identified. A correct diagnosis of HPC was made on one primary lesion and all recurrent or metastatic lesions. HPCs show a spindle cell pattern in cytologic preparations and must be distinguished from more common spindle cell lesions. The presence of branched capillaries and abundant basement membrane material supports a diagnosis of HPC. Immunohistochemistry and electron microscopy performed on FNA samples may be helpful in the differential diagnosis. FNA is a useful and accurate tool with which to confirm recurrent or metastatic HPC; however, prediction of the biologic behavior of HPC based on cytologic features is

  14. Toward improving fine needle aspiration cytology by applying Raman microspectroscopy

    NASA Astrophysics Data System (ADS)

    Becker-Putsche, Melanie; Bocklitz, Thomas; Clement, Joachim; Rösch, Petra; Popp, Jürgen

    2013-04-01

    Medical diagnosis of biopsies performed by fine needle aspiration has to be very reliable. Therefore, pathologists/cytologists need additional biochemical information on single cancer cells for an accurate diagnosis. Accordingly, we applied three different classification models for discriminating various features of six breast cancer cell lines by analyzing Raman microspectroscopic data. The statistical evaluations are implemented by linear discriminant analysis (LDA) and support vector machines (SVM). For the first model, a total of 61,580 Raman spectra from 110 single cells are discriminated at the cell-line level with an accuracy of 99.52% using an SVM. The LDA classification based on Raman data achieved an accuracy of 94.04% by discriminating cell lines by their origin (solid tumor versus pleural effusion). In the third model, Raman cell spectra are classified by their cancer subtypes. LDA results show an accuracy of 97.45% and specificities of 97.78%, 99.11%, and 98.97% for the subtypes basal-like, HER2+/ER-, and luminal, respectively. These subtypes are confirmed by gene expression patterns, which are important prognostic features in diagnosis. This work shows the applicability of Raman spectroscopy and statistical data handling in analyzing cancer-relevant biochemical information for advanced medical diagnosis on the single-cell level.

  15. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    PubMed

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  16. Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry.

    PubMed

    Yarmus, Lonny B; Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E; Ray, Cynthia; Greenhill, Sarah R; Jimenez, Carlos A; Filner, Joshua; Feller-Kopman, David

    2013-04-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle.

  17. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    PubMed

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  18. Cytopathologist-performed and ultrasound-guided fine needle aspiration cytology enhances diagnostic accuracy and avoids pitfalls: An overview of 20 years of personal experience with a selection of didactic cases.

    PubMed

    Paksoy, Nadir; Ozbek, Busra

    2018-01-01

    Over the last few decades, fine needle aspiration cytology (FNA) has emerged as a SAFE (Simple, Accurate, Fast, Economical) diagnostic tool based on the morphologic evaluation of cells. The first and most important step in obtaining accurate results from FNA is to procure sufficient and representative material from the lesion and to appropriately transfer this material to the laboratory. Unfortunately, the most important aspect of this task occurs beyond the control of the cytopathologist, a key reason for obtaining unsatisfactory results with FNA. There is growing interest in the field of cytology in "cytopathologist-performed ultrasound (US)-guided FNA," which has been reported to yield accurate results. The first author has been applying FNA in his own private cytopathology practice with a radiologist and under the guidance of US for more than 20 years. This study retrospectively reviews the utility of this practice. We present a selection of didactic examples under different headings that highlight the application of FNA by a cytopathologist, accompanied by US, under the guidance of a radiologist, in the form of an "outpatient FNA clinic." The use of this technique enhances diagnostic accuracy and prevents pitfalls. The highlights of each case are also outlined as "take-home messages."

  19. Sensitivity, Specificity, and Posttest Probability of Parotid Fine-Needle Aspiration: A Systematic Review and Meta-analysis.

    PubMed

    Liu, C Carrie; Jethwa, Ashok R; Khariwala, Samir S; Johnson, Jonas; Shin, Jennifer J

    2016-01-01

    (1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of nondiagnostic and indeterminate cytology with parotid FNA. Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I(2) statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I(2) point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509-0.982) and a specificity of 0.995 (95% CI, 0.960-0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030-0.075) and 0.147 (95% CI, 0.106-0.188), respectively. FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.

  20. Sensitivity, Specificity, and Posttest Probability of Parotid Fine-Needle Aspiration: A Systematic Review and Meta-analysis

    PubMed Central

    Liu, C. Carrie; Jethwa, Ashok R.; Khariwala, Samir S.; Johnson, Jonas; Shin, Jennifer J.

    2016-01-01

    Objectives (1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of non-diagnostic and indeterminate cytology with parotid FNA. Data Sources Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Review Methods Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I2 statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. Results The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I2 point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509–0.982) and a specificity of 0.995 (95% CI, 0.960–0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030–0.075) and 0.147 (95% CI, 0.106–0.188), respectively. Conclusion FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. PMID:26428476

  1. Development of a Tailored Thyroid Gland Phantom for Fine-Needle Aspiration Cytology by Three-Dimensional Printing.

    PubMed

    Baba, Masayuki; Matsumoto, Keitaro; Yamasaki, Naoya; Shindo, Hisakazu; Yano, Hiroshi; Matsumoto, Megumi; Otsubo, Ryota; John Lawn, Murray; Matsuo, Naoto; Yamamoto, Ikuo; Hidaka, Shigekazu; Nagayasu, Takeshi

    Fine-needle aspiration cytology (FNAC) is a challenging and risky procedure for inexperienced clinicians to perform because of the proximity of the thyroid to the jugular veins, carotid arteries, and trachea. A phantom model for transfixion practice would help train clinicians in FNAC. To fabricate a tailored phantom with consideration for authenticity of size, touch, feel, and ultrasonographic (US) characteristics. A three-dimensional (3D) digital model of the human neck was reconstructed from computed tomography data of a subject. This model was used to create 3D-printed templates for various organs that require US visualization. The templates were injected with polymers that provided similar degrees of ultrasound permeability as the corresponding organs. For fabrication of each organ, the respective molds of organs, blood vessels, thyroid gland, and tumor were injected with the material. The fabricated components were then removed from the templates and colored. Individual components were then positioned in the neck mold, and agar gel was poured in. The complete phantom was then removed from the mold. Thereafter, 45 medical doctors and students performed ultrasound-guided FNAC using the phantom, following which they were queried regarding the value of the phantom. The structure, US characteristics, and elasticity of the phantom were similar to those of the human subject. In the survey, all 45 participants replied that they found the phantom useful for FNAC training, and 30 medical students professed increased interest in thyroid diseases after using the phantom. We successfully fabricated a tailored thyroid gland phantom for transfixion practice. As most of the phantom parts are injected in molds fabricated using a 3D printer, they can be easily reproduced once the molds are fabricated. This phantom is expected to serve as an effective and fully tailored training model for practicing thyroid gland transfixion. Copyright © 2017. Published by Elsevier Inc.

  2. Role of Fine Needle Aspiration Cytology in the Diagnosis of Skin and Superficial Soft Tissue Lesions: A Study of 510 Cases.

    PubMed

    Bhowmik, Abhijit; Mallick Sinha, Mamata Guha; Barman, Dilip Chandra

    2015-01-01

    Diseases of the skin and superficial subcutaneous soft tissues present with a wide array of lesions ranging from nonspecific dermatoses and inflammatory lesions to frank neoplasms. Though cytopathology is an excellent diagnostic tool in routine dermatologic practice, studies relating to histopathological and cytological correlation are sparse. The aim of this study was to analyze the concordance rate between cytological and histopathological diagnosis of skin and superficial soft tissue lesions. We retrospectively studied 510 consecutive fine needle aspiration cytology findings of cases from North Bengal Medical College and Hospital and correlated their diagnoses based upon cytological and histopathological grounds. Out of the 510 cases studied, 253 were non neoplastic lesions and 257 were neoplastic. A high degree of concordance was observed (100% for malignant and 96.15% for benign lesions) when these two diagnostic modalities were compared. Histopathological correlation was possible in all malignant, 52/189 (27.51%) of benign and 27/253 (10.67%) of non-neoplastic lesions. Sensitivity and specificity of diagnoses were 95.31% and 97.6%, respectively. It can be safely concluded that fine needle aspiration cytology is a rapid, reliable and fairly accurate tool for initial triage and treatment of skin and superficial soft tissue lesions.

  3. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  4. Cytology of primary vaginal melanoma: An unusual report on fine needle aspiration.

    PubMed

    Agarwal, Poojan; Kaushal, Manju

    2017-03-01

    Primary malignant melanoma of the vagina is an extremely uncommon malignancy comprising of less than 10% malignancies of the female genital tract and 0.3% of all melanomas. Melanoblasts are neural crest derivatives and are notorious for causing primary cutaneous neoplasms. However, they involve virtually every organ of the body including eye, intestines and ocular mucosa, probably due to aberrancies in cell migration. Vagina is a rare site and primary melanoma of the vagina occurs in postmenopausal women with vaginal discharge, bleeding, or mass as common presenting complaints. Only a handful of case reports are available describing this entity on biopsy and PAP smear samples; however, fine needle aspiration has seldom been discussed. In the present report we discuss a case of an elderly female who complained of mass protruding through the vaginal opening, FNAC was done from the mass as well as from the right inguinal lymph node. An extensive clinicoradiological workup, and immunohistochemical confirmation is essential to rule out metastatic lesions and confirm primary. Diagn. Cytopathol. 2017;45:252-256. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Cancer cell profiling by barcoding allows multiplexed protein analysis in fine-needle aspirates.

    PubMed

    Ullal, Adeeti V; Peterson, Vanessa; Agasti, Sarit S; Tuang, Suan; Juric, Dejan; Castro, Cesar M; Weissleder, Ralph

    2014-01-15

    Immunohistochemistry-based clinical diagnoses require invasive core biopsies and use a limited number of protein stains to identify and classify cancers. We introduce a technology that allows analysis of hundreds of proteins from minimally invasive fine-needle aspirates (FNAs), which contain much smaller numbers of cells than core biopsies. The method capitalizes on DNA-barcoded antibody sensing, where barcodes can be photocleaved and digitally detected without any amplification steps. After extensive benchmarking in cell lines, this method showed high reproducibility and achieved single-cell sensitivity. We used this approach to profile ~90 proteins in cells from FNAs and subsequently map patient heterogeneity at the protein level. Additionally, we demonstrate how the method could be used as a clinical tool to identify pathway responses to molecularly targeted drugs and to predict drug response in patient samples. This technique combines specificity with ease of use to offer a new tool for understanding human cancers and designing future clinical trials.

  6. Cancer cell profiling by barcoding allows multiplexed protein analysis in fine needle aspirates

    PubMed Central

    Ullal, Adeeti V.; Peterson, Vanessa; Agasti, Sarit S.; Tuang, Suan; Juric, Dejan; Castro, Cesar M.; Weissleder, Ralph

    2014-01-01

    Immunohistochemistry-based clinical diagnoses require invasive core biopsies and use a limited number of protein stains to identify and classify cancers. Here, we introduce a technology that allows analysis of hundreds of proteins from minimally invasive fine needle aspirates (FNA), which contain much smaller numbers of cells than core biopsies. The method capitalizes on DNA-barcoded antibody sensing where barcodes can be photo-cleaved and digitally detected without any amplification steps. Following extensive benchmarking in cell lines, this method showed high reproducibility and achieved single cell sensitivity. We used this approach to profile ~90 proteins in cells from FNAs and subsequently map patient heterogeneity at the protein level. Additionally, we demonstrate how the method could be used as a clinical tool to identify pathway responses to molecularly targeted drugs and to predict drug response in patient samples. This technique combines specificity with ease of use to offer a new tool for understanding human cancers and designing future clinical trials. PMID:24431113

  7. Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    2011-01-01

    Background: New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. Methods: We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. Results: We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). Conclusions: To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further

  8. Percutaneous CT-Guided Biopsy of the Lung: Comparison Between Aspiration and Automated Cutting Needles Using a Coaxial Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurent, Francois; Latrabe, Valerie; Vergier, Beatrice

    2000-07-15

    Purpose: To compare the accuracy and complication rate of two different CT-guided transthoracic needle biopsy techniques: fine needle aspiration and an automated biopsy device.Methods: Two consecutive series of respectively 125 (group A) and 98 (group B) biopsies performed using 20-22 gauge coaxial fine needle aspiration (group A) and an automated 19.5 gauge coaxial biopsy device (group B) were compared in terms of their accuracy and complication rate.Results: Groups A and B included respectively 100 (80%) and 77 (79%) malignant lesions and 25 (20%) and 18 (21%) benign lesions. No significant difference was found between the two series concerning patients, lesions,more » and procedural variables. For a diagnosis of malignancy, a statistically significant difference in sensitivity was found (82.7% vs 97.4%) between results obtained with the automated biopsy device and fine needle aspiration respectively. For a diagnosis of malignancy, the false negative rate of the biopsy result was significantly higher (p <0.005) in group A (17%) than in group B (2.6%). For a specific diagnosis of benignity, no statistically significant difference was found between the two groups (44% vs 26%) but the automated biopsy device provided fewer indeterminate cases. There was no difference between the two groups concerning the pneumothorax rate, which was 20% in group A and 15% in group B, or the hemoptysis rate, which was 2.4% in group A and 4% in group B.Conclusion: For a diagnosis of malignancy when a cytopathologist is not available on-site, automated biopsy devices provide a lower rate of false negative results and a similar complication rate to fine needle aspiration.« less

  9. Breast fine-needle aspiration malondialdehyde deoxyguanosine adduct in breast cancer

    PubMed Central

    Peluso, Marco; Munnia, Armelle; Risso, Gabriella G.; Catarzi, Sandra; Piro, Sara; Ceppi, Marcello; Giese, Roger W.; Brancato, Beniamino

    2012-01-01

    This study has analysed the generation of 3-(2-deoxy-β-D-erythro-pentafuranosyl) pyrimido [1,2-α] purin-10 (3H)-one deoxyguanosine adduct [M1dG], a biomarker of oxidative stress and lipid peroxidation, in breast fine-needle aspirate samples of 22 patients with breast cancer, at different clinical stages, in respect to 13 controls. The multivariate analysis show that M1dG adduct was higher in cases than in controls (Mean Ratio (MR) = 5.26, 95% CI = 3.16–8.77). Increased M1dG was observed in women with a tumour grade 3 and a pathological diameter 2 (MR = 7.61, 95% CI 3.91–14.80 and MR = 5.75, 95% CI = 3.13–10.59, respectively). A trend with increasing tumour grade and pathological diameter was present (MR = 1.98, 95% CI = 1.57–2.50 and MR = 2.44, 95% CI = 1.71–3.48, respectively). Not significant effects of age and smoking habit were found (MR = 1.58, 95% CI = 0.92–2.72 and MR = 1.68, 95% CI 0.88–3.20, respectively). An increment over the background frequency of M1dG can contribute to breast cancer development. Increasing severity of breast tumour can influence DNA damage level. PMID:21250785

  10. Fine needle aspiration of secondary synovial sarcoma of the thyroid gland.

    PubMed

    Murro, Diana; Slade, Jamie Macagba; Syed, Sahr; Gattuso, Paolo

    2015-11-01

    Synovial sarcomas (SS) of the head and neck region are extremely rare and arise in only 5% of cases. We present a case of secondary SS of the thyroid originally diagnosed as medullary carcinoma on fine needle aspiration (FNA). A 41-year-old man presented with several weeks of dysphonia and a left thyroid mass. FNA of the thyroid nodule showed a cellular smear composed of loosely cohesive oval to spindle-shaped cells with irregular nuclear borders, finely granular chromatin, and inconspicuous nucleoli. The patient was diagnosed with medullary carcinoma and underwent a total thyroidectomy. Intro-operatively, the mass was found to arise from the tracheoesophageal groove with spread to the left thyroid. Microscopic examination of the thyroid tumor revealed a dense spindle cell proliferation with abundant mitoses, scant cords and nests of epithelial cells and foci of necrosis. The spindle cells were positive for bcl2 and vimentin and the epithelial cells were positive for cytokeratin 8/18 and epithelial membrane antigen (EMA). Both spindle and epithelial cells were negative for thyroglobulin, calcitonin, synaptophysin and chromogranin. Fluorescence in situ hybridization (FISH) demonstrated translocation (X;18)(p11;q11), confirming the diagnosis of SS. The patient underwent a total laryngopharyngoesophagectomy with subsequent adjuvant therapy and is currently disease free. Only 6 cases of histologically confirmed primary SS of the thyroid have been reported. To the best of our knowledge, this is the first case of FISH-confirmed secondary SS of the thyroid and also the first case of SS arising from the tracheoesophageal groove. © 2015 Wiley Periodicals, Inc.

  11. A technique to improve diagnostic information from fine-needle aspirations: immunohistochemistry on cytoscrape.

    PubMed

    Skov, Birgit Guldhammer; Kiss, Katalin; Ramsted, Julie; Linnemann, Dorte

    2009-04-25

    Cytologic examination of fine-needle aspiration (FNA) material is being used increasingly for the diagnosis of pulmonary lesions. Accurate distinction between nonsmall cell lung cancer (NSCLC), including subgroups, and small cell lung cancer and between primary lung cancer and metastases has therapeutic impact. However, the distinction between these groups may be difficult on smears. In this report, the authors describe a simple method, called cytoscrape (CS), which can be used on virtually any smear to produce material useful for ancillary methods, including immunohistochemistry. Aspirates from 47 patients who had possible malignant infiltrates identified on computed tomography scans of the chest were included. Smears were stained by May-Grunwald-Giemsa and Diff-Quick for diagnostic purposes. CS material was obtained by gently scraping cells off the slides. Clots were made, and the sections were stained for thyroid transcription factor-1 (TTF-1) and mucin. The utility of the CS technique was evaluated by assessing the sensitivity and specificity of the method and by quantifying the extra diagnostic information obtained by the method relative to smears alone. Malignant tumor cells in the CS material were identified in 43 aspirates (91%). Both the sensitivity and the specificity for TTF-1 were 100%. The sensitivity for mucin was 60%, and the specificity for mucin was 100%. The diagnoses made on smears were improved by CS in 31 patients (72%), in that more precise separation of subgroups of NSCLC was possible or information on primary tumors was obtained. The CS technique improved the diagnostic information from FNA in a clinically relevant way. The method is simple, quick, and inexpensive. (c) 2009 American Cancer Society.

  12. The value of fine needle aspiration cytology in the clinical management of rare salivary gland tumors

    PubMed Central

    Mezei, Tibor; Mocan, Simona; Ormenisan, Alina; Baróti, Beáta; Iacob, Alina

    2018-01-01

    Abstract Salivary gland tumors are relatively rare neoplasms, mostly located in the parotid gland, and few are malignant. Preoperative evaluation of salivary gland tumors includes fine needle aspiration cytology (FNAC). Objective The purpose of this study was to determine the importance of FNAC in the evaluation of rare salivary gland neoplasms. Material and Methods Four cases of rare salivary gland tumors were included, which were preoperatively assessed by clinical investigation, computed tomography, and FNAC. Results The presented cases include myoepithelial carcinoma, oncocytic carcinoma, undifferentiated lymphoepithelial carcinoma, and marginal zone lymphoma. Conclusion FNAC is a reliable diagnostic tool for common salivary gland neoplasms; however, rare tumors often represent diagnostic challenges. Clinical relevance In such rare tumors, the role of aspiration cytology may be limited to establishing the dignity of the lesion (benign/malignant). This knowledge enables the surgeon to choose the most appropriate therapeutic procedure. A definitive diagnosis of rare tumors (either epithelial or nonepithelial) is obtained by histological examination; cytology is limited in this regard due to overlapping features. PMID:29489937

  13. Fine-needle aspiration cytology of malignant hemangiopericytoma of the salivary gland: A case report.

    PubMed

    Shimizu, K; Ogura, S; Kobayashi, T K; Kushima, R; Toyokuni, S; Iwasa, Y; Sakurai, M

    1999-12-01

    A 79-yr-old woman presented with a 5-yr history of swelling of the left cheek. The fine-needle aspiration (FNA) smear showed a spindle-cell neoplasm with capillaries and benign endothelial cells. The spindle cells possessed pleomorphic, hyperchromatic elongated nuclei and a moderate amount of ill-defined cytoplasm. They also showed papillary arcades surrounded and encased by relatively small ovoid to short spindle cells. Subsequent surgical excision confirmed the presence of malignant hemangiopericytoma (HP). Immunohistochemical studies on the histologic section using vimentin were strongly positive, consistent with HP. To the best of our knowledge, this is the second published report of FNA cellular features of malignant HP of the salivary gland. Besides delineating the FNA cellular features of HP of the salivary gland, the present case illustrates the value of using immunohistochemical approaches. Diagn. Cytopathol. 1999;21:398-401. Copyright 1999 Wiley-Liss, Inc.

  14. Correlation of ultrasonographic appearance of lesions and cytologic and histologic diagnoses in splenic aspirates from dogs and cats: 32 cases (2002-2005).

    PubMed

    Ballegeer, Elizabeth A; Forrest, Lisa J; Dickinson, Ryan M; Schutten, Melissa M; Delaney, Fern A; Young, Karen M

    2007-03-01

    To determine the accuracy of cytologic diagnosis, compared with histologic diagnosis, in determination of disease in ultrasound-guided fine-needle aspirates of splenic lesions. Retrospective study. Splenic specimens from 29 dogs and 3 cats. Records were searched for dogs and cats that had undergone ultrasound-guided splenic aspiration. Criteria for inclusion were ultrasonographic identification of splenic lesions and cytologic and histologic evaluation of tissue from the same lesion. Cytologic samples were obtained by fine-needle aspiration, and histologic specimens were obtained via surgical biopsy, ultrasound-guided biopsy, or necropsy. Cytologic diagnoses corresponded with histologic diagnoses in 19 of 31 (61.3%) cases and differed in 5 of 31(16.1%) cases, and 1 aspirate was inadequate for evaluation. In 7 of 31 (22.6%) cases, histologic evaluation of tissue architecture was required to distinguish between reactive and neoplastic conditions. On the basis of histologic diagnosis in 14 animals with nonneoplastic conditions, the cytologic diagnosis was correct in 11 cases, not definitive in 2 cases, and incorrect in 1 case. In 17 animals with malignant neoplastic diseases, the cytologic diagnosis was correct in 8 cases, not definitive but consistent with possible neoplasia in 5 cases, and incorrect in 4 cases. Multiple similar-appearing nodules were significantly associated with malignancy, whereas single lesions were more often benign. Ultrasound-guided aspiration of splenic lesions is a minimally invasive tool for obtaining specimens for cytologic evaluation. Although cytologic diagnoses often reflect histologic results, if missampling or incomplete sampling occurs or tissue architecture is required to distinguish between reactive and neoplastic conditions, accurate diagnosis with fine-needle aspiration may not be possible.

  15. Hyalinizing Trabecular Tumor of the Thyroid Gland, a Diagnostic Challenge in Fine-Needle Aspiration Cytology: Case Report.

    PubMed

    Rhee, Ye-Young; Jung, Hong Kyu; Kim, Se Hoon; Kim, Soo Hee

    2018-06-11

    Hyalinizing trabecular tumor (HTT) is a rare thyroid tumor with low to minimal malignant potential. HTT is often misinterpreted as other thyroid tumors, including papillary thyroid carcinoma (PTC) and medullary thyroid carcinoma (MTC), on fine-needle aspiration (FNA) cytology, because of its overlapping cytologic features, such as nuclear grooves and intranulcear pseudoinclusions. Although cytopathologists cannot definitely conclude HTT by FNA cytology, suspicion of HTT is necessary to avoid misdiagnosing HTT as PTC or MTC and to avoid unnecessary aggressive treatment. Here, we report a case of HTT with novel cytologic features in CellPrep liquid based cytology that was diagnosed as suspicious for papillary carcinoma by FNA and finally diagnosed as HTT in the surgical specimen.

  16. Needle Biopsy

    MedlinePlus

    ... needle biopsy procedures include fine-needle aspiration and core needle biopsy. Needle biopsy may be used to ... hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses ...

  17. A Rare and Severe Complication Following Thyroid Fine Needle Aspiration: Retropharyngeal Cellulitis

    PubMed Central

    Cesareo, Roberto; Naciu, Anda; Barberi, Antonio; Pasqualini, Valerio; Pelle, Giuseppe; Manfrini, Silvia; Tabacco, Gaia; Pantano, Angelo Lauria; Campagna, Giuseppe; Cianni, Roberto; Palermo, Andrea

    2016-01-01

    Introduction Fine needle aspiration (FNA) is the most accurate and cost-effective method for evaluating thyroid nodules. We have reported a rare complication related to the procedure: severe retropharyngeal cellulitis. Case Presentation A thirty-five-year-old female was admitted to hospital with hoarseness, laryngeal stridor and dyspnea without fever that emerged about 3 days after a first diagnostic FNA. After the procedure, the patient felt her voice became hoarse and 1 day before presentation began to have dyspnea, without fever. It had become difficult for her to swallow solids, and she felt as if food was sticking in her throat. In the emergency room, hematochemical tests and CT scan of the neck/mediastinum had been performed. This showed leukocytosis with neutrophilia and a severe cellulitis framework with involvement of the laterocervical neck area and in particular, the invasion of the retropharynx and the upper part of the mediastinum. The patient was admitted in hospital for an anti-inflammatory therapy with cortisone and antibiotic therapy. Conclusions For the first time to our knowledge, we have reported a severe retropharyngeal and upper mediastinum cellulitis, probably due to the FNA procedure in an immunocompetent young woman. PMID:28123438

  18. [Diagnostic accuracy of fine needle aspiration cytology in parotid tumours].

    PubMed

    Zerpa Zerpa, Vanessa; Cuesta Gonzáles, Maria Teresa; Agostini Porras, Gabriela; Marcano Acuña, Martin; Estellés Ferriol, Enrique; Dalmau Galofre, José

    2014-01-01

    Fine needle aspiration cytology (FNAC) is a globally accepted technique in the preoperative evaluations of head and neck tumours; however, the effectiveness in the interpretation of salivary glands neoplastic lesions is still controversial. The objective of this study consisted of assessing the efficacy of FNAC in preoperative diagnosis of parotid tumours. This retrospective study was conducted using 93 patient samples with parotid gland tumoral pathology, treated at the Otorhinolaryngology Department in our institution during the 2007-2011 period. Preoperative FNAC was employed and the patients subsequently submitted to surgical excision with histopathological diagnosis of the specimen. Cytology results were classified as negative for malignancy, positive for malignancy or insufficient sample, and later compared with the definitive histological diagnosis. The mean age of the studied sample was 52.9 years (range: 11 to 88 years); 55.9% were men. The FNAC showed significant sensitivity of 57.1%, with a specificity of 95.1%, for detecting malignancy in parotid gland tumours. The positive and negative predictive values for malignancy were 50 and 96.3%, respectively. FNAC is considered a simple test but of limited use for diagnostic guidance in tumour pathology of the parotid gland in our environment, mainly because of its low sensitivity. However, the high specificity and high negative predictive value of FNAC makes it a more accurate test in benign or negative result cases. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  19. Next-Generation Sequencing Identifies Gene Mutations That Are Predictive of Malignancy in Residual Needle Rinses Collected From Fine-Needle Aspirations of Thyroid Nodules.

    PubMed

    Fuller, Maren Y; Mody, Dina; Hull, April; Pepper, Kristi; Hendrickson, Heather; Olsen, Randall

    2018-02-01

    - Thyroid nodules have a prevalence of approximately 70% in adults. Fine-needle aspiration (FNA) is a minimally invasive, cost-effective, standard method to collect tissue from thyroid nodules for cytologic examination. However, approximately 15% of thyroid FNA specimens cannot be unambiguously diagnosed as benign or malignant. - To investigate whether clinically actionable data can be obtained using next-generation sequencing of residual needle rinse material. - A total of 24 residual needle rinse specimens with malignant (n = 6), indeterminate (n = 9), or benign (n = 9) thyroid FNA diagnoses were analyzed in our clinical molecular diagnostics laboratory using next-generation sequencing assays designed to detect gene mutations and translocations that commonly occur in thyroid cancer. Results were correlated with surgical diagnoses and clinical outcomes. - Interpretable data were generated from 23 of 24 residual needle rinse specimens. Consistent with its well-known role in thyroid malignancy, BRAF V600E mutations were detected in 4 malignant cases. An NRAS mutation was detected in 1 benign case. No mutations were detected from specimens with indeterminate diagnoses. - Our data demonstrate that residual thyroid FNA needle rinses are an adequate source of material for molecular diagnostic testing. Importantly, detection of a mutation implicated in thyroid malignancy was predictive of the final surgical diagnosis and clinical outcome. Our strategy to triage thyroid nodules with indeterminate cytology with molecular testing eliminates the need to perform additional FNA passes into dedicated media or to schedule additional invasive procedures. Further investigation with a larger sample size to confirm the clinical utility of our proposed strategy is underway.

  20. Comparison of two different size needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing solid pancreatic lesions

    PubMed Central

    Xu, Mei-Mei; Jia, Hong-Yu; Yan, Li-Li; Li, Shan-Shan; Zheng, Yue

    2017-01-01

    Abstract Background: This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. Methods: We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. Results: Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%–95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%–91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65–28.14) and 0.16 (95% CI, 0.12–0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65–28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12–0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87–18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09–0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. Conclusion: Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS–FNA. PMID:28151856

  1. Incidental primary mediastinal choriocarcinoma diagnosed by endobronchial ultrasound-guided fine needle aspiration in a patient presenting with transient ischemic attack and stroke.

    PubMed

    Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer

    2017-08-01

    We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Mediastinal abscess after endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2013-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.

  3. Acquired toxoplasmosis of a submandibular lymph node in a 9-year-old boy diagnosed by fine-needle aspiration cytology.

    PubMed

    Macey-Dare, L V; Kocjan, G; Goodman, J R

    1996-12-01

    Toxoplasmosis is a parasitic infection which may be asymptomatic or produce lymphadenopathy, fever and malaise. In children the cervical lymph nodes are most commonly affected. This report describes a case of a 9-year-old boy who presented with submandibular lymphadenopathy associated with a non-vital primary tooth, which persisted following extraction of the tooth. A diagnosis of acquired toxoplasmosis was made on the findings of fine-needle aspiration cytology and subsequently confirmed by serological investigations, thus sparing the patient unnecessary hospitalization and surgery. The patient required amitryptyline as a nocturnal sedative and made a complete recovery within a few months without the need for further intervention.

  4. Cytotechnologist performance for screening microfollicular atypia in indeterminate thyroid fine-needle aspirates.

    PubMed

    VandenBussche, Christopher J; Olson, Matthew T; Adams, Christina; Ali, Syed Z

    2014-01-01

    We previously identified a high level of accuracy among our cytotechnologists (CTs) for identifying nuclear atypia in thyroid fine-needle aspiration (FNA) specimens. Herewith, we present our CT performance at screening for microfollicular atypia. 8,814 thyroid FNA specimens were identified in our archives, all screened by 1 of 11 CTs and signed out by a cytopathologist. A subsample of cases was categorized either as atypia of uncertain significance (AUS) with microfollicular proliferation (AUS-F) or suspicious for a follicular neoplasm (SFN). The agreement rate was low between CTs and cytopathologists for SFN and AUS-F. Only 55.8% of SFN screening diagnoses were upheld; 27.9% were downgraded to AUS, 10.4% were downgraded to benign, and 5% were upgraded. Of AUS-F screening diagnoses, 35.5% were upheld, 33.7% were downgraded to benign, and 20.2% were upgraded to SFN. Among all cases, two-step discrepancies were uncommon. Most disagreements were one-category discrepancies between AUS-F and SFN. The evaluation of microfollicular atypia is challenging given that certain follicular lesions cannot be definitively diagnosed on cytology, a high level of subjectivity is involved in the interpretation of such lesions, and the presence of nuclear or Hurthle cell atypia may complicate the diagnosis. © 2014 S. Karger AG, Basel.

  5. A rare constellation of empyema, lung abscess, and mediastinal abscess as a complication of endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen

    2011-07-01

    The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  6. Thin-needle aspiration biopsy of the prostate.

    PubMed

    Koss, L G; Woyke, S; Schreiber, K; Kohlberg, W; Freed, S Z

    1984-05-01

    The authors summarize the current status of thin-needle aspiration biopsy of the prostate and evaluate the accomplishments and limitations of this method of diagnosis. Historical developments, indications, technique, contraindications, complications, cytology of aspirates, diagnostic efficacy of aspirates, and grading of prostatic carcinomas are discussed.

  7. Pituitary carcinoma diagnosed on fine needle aspiration: Report of a case and review of pathogenesis

    PubMed Central

    Yakoushina, Tatiana V.; Lavi, Ehud; Hoda, R. S.

    2010-01-01

    Pituitary carcinoma (PC) is a very rare entity (0.2% of all pituitary tumors), with only about 140 cases reported in English literature. There are no reliable histological, immunohistochemical or ultrastructural features distinguishing pituitary adenoma (PA) from PC. By definition, a diagnosis of PC is made after a patient with PA develops non-contiguous central nervous system (CNS) or systemic metastases. To date, only three cases of PC have been reportedly diagnosed on fine needle aspiration (FNA). Two of the reported cases were diagnosed on FNA of the cervical lymph nodes and one on FNA of the vertebral bone lesion. Herein, we present a case of PC, diagnosed on FNA of the liver lesion. In this case, we describe cytologic features of PC and compare them to histologic features of the tumor in the pituitary. Clinical behavior of tumor, pathogenesis of metastasis and immunochemical and prognostic markers will also be described. PMID:20806088

  8. Aspiration of breast abscess under ultrasound guidance: outcome obtained and factors affecting success.

    PubMed

    Elagili, Faisal; Abdullah, Norlia; Fong, Liew; Pei, Tan

    2007-01-01

    To assess ultrasonographically (US) guided needle aspiration of breast abscesses as an alternative to surgical incision and drainage. In our prospective study, 30 patients with 31 breast abscesses (one patient had bilateral breast abscess) underwent percutaneous breast abscess drainage under US guidance with local anaesthesia and oral antibiotics between 1 January 2004 and 31 March 2005. These patients consisted of 16 (53.3%) non-lactating and 14 (46.7%) lactating women, with ages ranging from 18 to 68 years (median, 28 years). The racial distribution comprised 26 (86.7%) Malays, three (10%) Chinese and one (3.3%) Indian. All patients had the chief complaint of breast swelling and 25 (83.3%) had breast pain. Clinically, 28 (93.3%) were found to have a palpable mass. Nine (30%) lesions were in the upper outer quadrant of the left breast. US diameters ranged from 1 to 15 cm (median, 4 cm). The pus volumes varied from 1 to 200 mL (median, 14 mL). Fifteen (50%) patients required only a single aspiration, 10 required multiple aspirations and five required incision and drainage. Those patients in whom needle aspiration failed had multiloculated lesions irrespective of abscess volume and size. Needle aspiration with ultrasound guidance is an effective treatment for breast abscess irrespective of abscess volume and size.

  9. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics.

    PubMed

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J; Sobrinho Simoes, Manuel

    2017-07-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF , NRAS , HRAS , KRAS , PAX8/PPARG , RET/PTC ) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation.

  10. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics

    PubMed Central

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J.; Sobrinho Simoes, Manuel

    2017-01-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF, NRAS, HRAS, KRAS, PAX8/PPARG, RET/PTC) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation. PMID:28785538

  11. Bronchoscopy with endobronchial ultrasound guided transbronchial needle aspiration vs. transthoracic needle aspiration in lung cancer diagnosis and staging.

    PubMed

    Munoz, Mark L; Lechtzin, Noah; Li, Qing Kay; Wang, KoPen; Yarmus, Lonny B; Lee, Hans J; Feller-Kopman, David J

    2017-07-01

    In evaluating patients with suspected lung cancer, it is important to not only obtain a tissue diagnosis, but also to obtain enough tissue for both histologic and molecular analysis in order to appropriately stage the patient with a safe and efficient strategy. The diagnostic approach may often be dependent on local resources and practice patterns rather than current guidelines. We Describe lung cancer staging at two large academic medical centers to identify the impact different procedural approaches have on patient outcomes. We conducted a retrospective cohort study of all patients undergoing a lung cancer diagnostic evaluation at two multidisciplinary centers during a 1-year period. Identifying complication rates and the need for multiple biopsies as our primary outcomes, we developed a multivariate regression model to determine features associated with complications and need for multiple biopsies. Of 830 patients, 285 patients were diagnosed with lung cancers during the study period. Those staged at the institution without an endobronchial ultrasound (EBUS) program were more likely to require multiple biopsies (OR 3.62, 95% CI: 1.71-7.67, P=0.001) and suffer complications associated with the diagnostic procedure (OR 10.2, 95% CI: 3.08-33.58, P<0.001). Initial staging with transthoracic needle aspiration (TTNA) and conventional bronchoscopy were associated with greater need for subsequent biopsies (OR 8.05 and 14.00, 95% CI: 3.43-18.87 and 5.17-37.86, respectively) and higher complication rates (OR 37.75 and 7.20, 95% CI: 10.33-137.96 and 1.36-37.98, respectively). Lung cancer evaluation at centers with a dedicated EBUS program results in fewer biopsies and complications than at multidisciplinary counterparts without an EBUS program.

  12. Cloned foal derived from in vivo matured horse oocytes aspirated by the short disposable needle system.

    PubMed

    Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun; Yeon, Seongchan; Jang, Goo

    2015-01-01

    Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology.

  13. A study of Galactin-3 on fine needle aspiration as a diagnostic marker differentiating benign from malignant thyroid neoplasm

    PubMed Central

    Muzafar, Alliya; Bukhari, Mulazim Hussain; Qureshi, Ihtesham uddin

    2017-01-01

    Background & Objective: Thyroid nodules are very common in our setup and their diagnosis on fine needle aspiration is not easy and is a taxing affair. It is a challenge to differentiate between follicular adenoma and follicular carcinoma without histology. Our objective was to investigate the role of Galectin-3 in fine needle aspirates of thyroid nodules as a prospective diagnostic marker and consequently its ability to differentiate benign from malignant neoplasms. Methods: The research was conducted at the department of Pathology, King Edward Medical University, in association with other teaching institutions of Lahore from June 2012 to July 2014.. Sixty cases of solitary thyroid nodules were included in the study. Haematoxylin and eosin staining of the fixed smears and Galectin-3 immunohistochemical staining of the sections prepared from the cell block was performed. Results: There were 60 patients in our study with a mean age of 33.35 years. The Bethesda system for reporting thyroid cytopathology was used to classify the smears and only categories IV, V and VI were included. On histological examination of the resected nodules there were 38.3% (23/60) cases of follicular adenoma, 46.6% (28/60) were of papillary carcinoma and follicular carcinoma made up to 15% (9/60) of all cases. Galectin-3 was negative in 100% (23/23) cases of follicular adenomas. Out of 37 malignant cases 65% lesions showed positivity, while 35% showed negativity for this immunomarker. Considering the malignant lesions, 75% cases of papillary carcinomas showed a positive reaction while only 33% of follicular carcinomas were positive for the immunomarker. This showed that the positive expression was more common in papillary as compared to follicular carcinomas. Conclusion: Galectin-3immunomarker is considerably expressed in malignant tumors, but it is not expressed in benign follicular lesions. PMID:28811803

  14. Fine-needle aspiration of low-grade adenosquamous carcinomas of the breast: a report of three new cases.

    PubMed

    Bataillon, Guillaume; Collet, Jean-François; Voillemot, Nicole; Menet, Emmanuelle; Vincent-Salomon, Anne; Klijanienko, Jerzy

    2014-01-01

    To describe cytology patterns in low-grade adenosquamous carcinomas (LGASCs) of the breast. Low-grade adenosquamous carcinomas of the breast are a recently described rare variant of primary metaplastic carcinomas characterized by clinical indolence, slow evolution and excellent survival. To date, only 7 cases of LGASC were studied cytologically, and it was demonstrated that LGASC identification was difficult because its cellular components exhibited unspecific and nonsuspicious features. They consisted of irregularly clustered cells without prominent cytonuclear atypia, mitosis or necrosis. The presence of metaplastic cells or keratin debris was helpful in accurate tumor typing. We report here 3 additional cases of LGASC that were initially studied by fine-needle aspiration. We have also encountered diagnostic difficulties and misdiagnosed tumors, since 2 cases were underdiagnosed as 'suspicious' and only 1 was accurately diagnosed as malignancy. The review of our cases and the literature confirms that, despite its putative metaplastic origin, LGASC is an entity which is difficult to diagnose using classical cytological methods. Moreover, core-needle biopsy as well as frozen sections may also misdiagnose LGASC as a benign breast lesion. © 2014 S. Karger AG, Basel.

  15. Ultrasound-Guided Transcutaneous Needle Biopsy of the Base of the Tongue and Floor of the Mouth From a Submental Approach.

    PubMed

    Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M

    2016-05-01

    Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.

  16. An investigation into false-negative transthoracic fine needle aspiration and core biopsy specimens.

    PubMed

    Minot, Douglas M; Gilman, Elizabeth A; Aubry, Marie-Christine; Voss, Jesse S; Van Epps, Sarah G; Tuve, Delores J; Sciallis, Andrew P; Henry, Michael R; Salomao, Diva R; Lee, Peter; Carlson, Stephanie K; Clayton, Amy C

    2014-12-01

    Transthoracic fine needle aspiration (TFNA)/core needle biopsy (CNB) under computed tomography (CT) guidance has proved useful in the assessment of pulmonary nodules. We sought to determine the TFNA false-negative (FN) rate at our institution and identify potential causes of FN diagnoses. Medical records were reviewed from 1,043 consecutive patients who underwent CT-guided TFNA with or without CNB of lung nodules over a 5-year time period (2003-2007). Thirty-seven FN cases of "negative" TFNA/CNB with malignant outcome were identified with 36 cases available for review, of which 35 had a corresponding CNB. Cases were reviewed independently (blinded to original diagnosis) by three pathologists with 15 age- and sex-matched positive and negative controls. Diagnosis (i.e., nondiagnostic, negative or positive for malignancy, atypical or suspicious) and qualitative assessments were recorded. Consensus diagnosis was suspicious or positive in 10 (28%) of 36 TFNA cases and suspicious in 1 (3%) of 35 CNB cases, indicating potential interpretive errors. Of the 11 interpretive errors (including both suspicious and positive cases), 8 were adenocarcinomas, 1 squamous cell carcinoma, 1 metastatic renal cell carcinoma, and 1 lymphoma. The remaining 25 FN cases (69.4%) were considered sampling errors and consisted of 7 adenocarcinomas, 3 nonsmall cell carcinomas, 3 lymphomas, 2 squamous cell carcinomas, and 2 renal cell carcinomas. Interpretive and sampling error cases were more likely to abut the pleura, while histopathologically, they tended to be necrotic and air-dried. The overall FN rate in this patient cohort is 3.5% (1.1% interpretive and 2.4% sampling errors). © 2014 Wiley Periodicals, Inc.

  17. Ultrasound guided fine-needle aspiration biopsy of thyroid nodules: Guidelines and recommendations vs clinical practice; a 12-month study of 89 patients.

    PubMed

    Peli, M; Capalbo, E; Lovisatti, M; Cosentino, M; Berti, E; Mattai Dal Moro, R; Cariati, M

    2012-06-01

    Given the high prevalence of thyroid nodules in the general population it is essential to develop a method for identifying those nodules which require fine-needle aspiration biopsy (FNAB) due to suspicion for malignancy in order to avoid over- or under treatment of this disease. The ultrasound (US) criteria identified by Kim et al. and the American Association of Clinical Endocrinologists appear to be the most sensitive and most specific. The purpose of this study was to analyze a sample of patients who underwent FNAB of the thyroid and to compare the obtained data with the international guidelines and the recommendations for management of thyroid nodules. This study analyzed the clinical, anamnestic and US reasons for which 97 nodules located in 89 patients underwent FNAB, and the data were compared with the criteria set by the guidelines and with the cytological results. Echogenicity was indication for FNAB in 99% of cases, appearance of the margins in 75.3%, presence of calcifications in 93.8% and presence of vascularity in 73.2%. In a total of 4.1% of cases, cytological outcome was positive for malignancy, 21.6% necessitated monitoring, 4.1% were referred to surgery and histological examination of the surgical specimen and 63.9% resulted negative for malignancy. The finding of hypoechoic nodules often leads to continued investigation; the presence of intranodular vascularization detected at Doppler US is perceived as suspicious and the presence of microcalcifications always leads to further investigation. On the request of the endocrinologist the dominant nodule in a goiter is in most cases subjected to FNAB even if the volume has not increased. Adequate US criteria can help identify potentially malignant nodules and guide implementation of FNAB. However, identification of malignant nodules using instrumental investigation cannot disregard medical records and clinical laboratory tests. According to the authors' experience, a close collaboration between

  18. Fine-needle aspiration of lipoblastoma: Cytological, molecular, and clinical features.

    PubMed

    Ferreira, Joana; Esteves, Gonçalo; Fonseca, Ricardo; Martins, Carmo; André, Saudade; Lemos, Maria Manuel

    2017-12-01

    Lipoblastomas are rare, benign adipocytic tumors that present mostly during infancy. In about 70% of cases, these tumors carry abnormalities in chromosome 8, mainly leading to rearrangements of the PLAG1 gene. We report a series of histologically proven lipoblastomas with previous fine-needle aspiration (FNA) cytology from 9 patients (n = 10 samples) and describe their clinical, cytological, and molecular features. Our cohort included 5 boys and 4 girls (median age, 2.5 years [range, 10 months to 13 years]) who presented with soft tissue masses in the thorax (n = 3), abdomen (n = 2), axilla (n = 2), and thigh (n = 2). In 1 patient, the FNA diagnosis was inconclusive due to hypocellularity, and in another patient a diagnosis of benign lipomatous tumor was made. In the remaining 8 samples (one of which confirmed relapse), a correct preoperative FNA diagnosis was rendered. Smears were hypo- to moderately cellular and contained fragments of mature adipose tissue with thin branching vessels admixed with some lipoblasts in a myxoid matrix. Spindle cells and naked oval nuclei with no atypia were observed in the background. Of the 4 patients tested for PLAG1 rearrangement using FISH probes, 3 harbored this alteration (1 was made on a FNA smear and 1 was made in a tumor imprint). All the patients are alive and well, except for 1 patient with a retroperitoneal tumor who, after an initial incomplete excision, died of local disease progression. FNA, especially if used together with molecular biology techniques (eg, PLAG1 FISH analysis), is a reliable and accurate diagnostic tool. Cancer Cytopathol 2017;125:934-9. © 2017 American Cancer Society. © 2017 American Cancer Society.

  19. Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules.

    PubMed

    Arias, Sixto; Lee, Hans; Semaan, Roy; Frimpong, Bernice; Ortiz, Ricardo; Feller-Kopman, David; Oakjones-Burgess, Karen; Yarmus, Lonny

    2015-05-23

    Lung nodule evaluation represents a clinical challenge especially in patients with intermediate risk for malignancy. Multiple technologies are presently available to sample nodules for pathological diagnosis. Those technologies can be divided into bronchoscopic and non-bronchoscopic interventions. Electromagnetic navigational bronchoscopy is being extensively used for the endobronchial approach to peripheral lung nodules but has been hindered by anatomic challenges resulting in a 70% diagnostic yield. Electromagnetic navigational guided transthoracic needle lung biopsy is novel non-bronchoscopic method that uses a percutaneous electromagnetic tip tracked needle to obtain core biopsy specimens. Electromagnetic navigational transthoracic needle aspiration complements bronchoscopic techniques potentially allowing the provider to maximize the diagnostic yield during one single procedure. This article describes a novel integrated diagnostic approach to pulmonary lung nodules. We propose the use of endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) for mediastinal staging; radial EBUS, navigational bronchoscopy and E-TTNA during one single procedure to maximize diagnostic yield and minimize the number of invasive procedures needed to obtain a diagnosis. This manuscript describes in detail how the navigation transthoracic procedure is performed. Additional clinical studies are needed to determine the clinical utility of this novel technology.

  20. Comparison of Core-Needle Biopsy and Fine-Needle Aspiration for Evaluating Thyroid Incidentalomas Detected by 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: A Propensity Score Analysis.

    PubMed

    Suh, Chong Hyun; Choi, Young Jun; Lee, Jong Jin; Shim, Woo Hyun; Baek, Jung Hwan; Chung, Han Cheol; Shong, Young Kee; Song, Dong Eun; Sung, Tae Yon; Lee, Jeong Hyun

    2017-10-01

    This study used a propensity score analysis to assess the roles of core-needle biopsy (CNB) and fine-needle aspiration (FNA) in the evaluation of thyroid incidentalomas detected on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT). The study population was obtained from a historical cohort who underwent 18 F-FDG PET/CT between October 2008 and September 2015. Patients were included who underwent ultrasound-guided CNB or FNA for incidental focal uptake of 18 F-FDG in the thyroid gland on PET/CT. The primary study outcomes included the inconclusive result rates in the CNB and FNA groups. The secondary outcome measures included the non-diagnostic result rate and the diagnostic performance for neoplasms. Multivariate analysis, propensity score matching, and inverse probability weighting were conducted. A total of 1360 nodules from 1338 patients were included in this study: 859 nodules from 850 patients underwent FNA, and 501 nodules from 488 patients underwent CNB. Compared to FNA, CNB demonstrated a significantly lower inconclusive result rate in the pooled cohort (23.8% vs. 35.4%; p < 0.001), propensity score-matched cohorts (22.9% vs. 36.6%; p < 0.001), and with inverse probability weighting (22.4% vs. 35.2%; p < 0.001). Non-diagnostic result rates were also significantly lower in CNB than in FNA. The diagnostic performance of the two groups in the pooled and matched cohorts was similar, with no significant differences found. The significantly lower inconclusive result rates in CNB than in FNA were consistent within the propensity score-matched cohorts. Therefore, CNB appears to be a promising diagnostic tool for patients with thyroid incidentalomas detected on 18 F-FDG PET/CT.

  1. A Solid Pseudopapillary Tumour of the Head of Pancreas: A Rare Case Report Diagnosed by Fine Needle Aspiration Cytology

    PubMed Central

    Deshpande, Archana Hemant; Chhadi, Shyam Atmaram; Kumbhalkar, Dinkar T; Raut, Waman K

    2016-01-01

    Solid Pseudopapillary Tumour (SPPT) is a distinctive tumour of low malignant potential with a striking and unexplained predilection for adolescent girls and young women. Hence it is important to distinguish this rare tumour from other pancreatic tumours with similar cytomorphologic features because an accurate preoperative diagnosis is highly desirable since these patients can have long survival with adequate surgery. We report a case of the rare SPPT of the pancreas in a young girl who presented with nonspecific pain in the abdomen. Radiological investigations revealed a solid cystic mass in relation to the uncinate process of pancreas and third part of duodenum. The mass was diagnosed to be a solid pseudopapillary neoplasm of pancreas on ultrasound guided FNAC. Surgical removal of the pancreatic tumour and detailed histologic study confirmed the cytologic diagnosis. We present this case because, to date, there are few case reports on the cytological diagnosis of this tumour, about 60 cases, diagnosed by Fine-Needle Aspiration Cytology (FNAC) are reported in the literature. With widespread availability of high-quality imaging systems and a better understanding of its pathology, the number of cases reported in the literature has been steadily increasing in recent years. In our case, the cytological diagnosis was done even before the detailed imaging findings were available, the cytological features of this tumour are highly characteristic and it is possible to differentiate it from other pancreatic tumours with relative ease. PMID:27504299

  2. Fine-needle aspiration study of cystic papillary thyroid carcinoma: Rare cytological findings

    PubMed Central

    Mokhtari, Maral; Kumar, Perikala Vijayananda; Hayati, Kamran

    2016-01-01

    Background: Cystic papillary thyroid carcinoma (CPTC) is a variant of papillary carcinoma that has many mimickers in cytological grounds. Aim: To study the cytomorphologic features of CPTC and compare them to those of other cystic thyroid lesions using fine-needle aspiration cytology (FNAC). We also aimed to identify the cytomorphologic features that distinguish CPTC from other cystic thyroid lesions. Materials and Methods: Seventy-three cases of CPTC were included in the study. The cytomorphologic features of these cases were analyzed. The FNA smears of other thyroid lesions with cystic changes (300 colloid goiters, 290 adenomatoid nodules, 11 follicular neoplasms, and 9 hurtle cell neoplasm) were also studied. Results: The smears in CPTC revealed isolated follicular cells, small groups of cells with scalloped margins, cell swirls, small clusters with a cartwheel pattern, papillary clusters, intranuclear inclusions, nuclear grooves, sticky colloid, intracellular colloids, psammoma bodies, multinucleated giant cells, and foamy and hemosiderin laden macrophages. Small groups of cells with scalloped borders, cellular swirls, and small clusters with a cartwheel pattern were seen in CPTC, but not in other cystic lesions. Interestingly, mesothelial-like cells and hemophagocytic cells were seen in five and three cases of CPTC, respectively, but not in other cystic lesions. Conclusion: Mesothelial-like cells and hemophagocytic cells were observed in five and three cases of CPTC, respectively. Similar finding have not been previously reported in the literature. PMID:27756982

  3. Risks and benefits in treatment of mediastinal abscess by endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Tian, Lei; Krimsky, William S; Wu, Qingchen; Sun, Jiayuan

    2017-07-01

    Mediastinal abscess is a fatal condition, treatment of mediastinal abscess is with antibiotics and sometimes surgery for debridement and drainage. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe assessment and candidate treatment method of mediastinal lesions. This study aimed to HYPERLINK "javascript:void(0);" discuss risks and benefits in treatment of mediastinal abscess by EBUS-TBNA. We noticed a 56-year-old man with developed bilateral pneumonia and sepsis after puncture of mediastinal abscess by EBUS-TBNA. The patient was successfully treated with a combination of systemic anti-infection treatment and intracavitary administration of antibiotics, antifungal and repeated drainage and lavage via EBUS-TBNA, in 1 year follow-up without recurrence. This study indicated infection spread risk of mediastinal abscess after EBUS-TBNA, and mediastinal abscess was successfully cured by combination of systemic anti-infection and local intervention through EBUS-TBNA. EBUS-TBNA is a potential effective minimally invasive treatment for mediastinal abscess, and it is necessary to be aware of clinical complications after puncture of mediastinal infectious lesions by EBUS-TBNA. © 2015 John Wiley & Sons Ltd.

  4. Needle tip visibility in 3D ultrasound images

    NASA Astrophysics Data System (ADS)

    Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo

    2017-03-01

    Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.

  5. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types

    PubMed Central

    Lytvynchuk, Lyubomyr; Sergienko, Andrij; Savytska, Iryna; Albert, Réka; Glittenberg, Carl; Binder, Susanne; Petrovski, Goran

    2017-01-01

    A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI) using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G) and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements. PMID:28692684

  6. Role of fine needle aspiration cytology in the preoperative investigation of branchial cysts.

    PubMed

    Slater, Jacqueline; Serpell, Jonathan W; Woodruff, Stacey; Grodski, Simon

    2012-01-01

    Successful preoperative diagnosis of a branchial cyst requires a systematic approach. The aim of this study was to evaluate methods of investigation of a lateral neck swelling suspicious for a branchial cyst, and to highlight cases where a less benign cause for the swelling should be suspected and therefore management altered appropriately. A retrospective case study of 24 patients with presumed branchial cysts managed operatively was undertaken. Demographic, clinical, imaging, cytology and histopathological data were analysed to formulate an approach to the work-up of a lateral neck swelling suspected to be a branchial cyst. All 24 patients presented with a lateral neck mass thought to be a branchial cyst preoperatively underwent preoperative fine-needle aspiration cytology. The overall accuracy of cytology in predicting a benign branchial cyst histopathologically was 83.3% (20 out of 24). Successful preoperative diagnosis of a branchial cyst requires a combination of imaging and cytology. If there is concern that a lateral neck swelling is not a branchial cyst on clinical, imaging or cytological features, then a full preoperative work-up, including computed tomography scan of the neck and upper aero-digestive tract endoscopy should be performed, prior to an excisional biopsy. © 2011 The Authors. ANZ Journal of Surgery © 2011 Royal Australasian College of Surgeons.

  7. Detection of mitochondrial DNA mutations in primary breast cancer and fine-needle aspirates.

    PubMed

    Parrella, P; Xiao, Y; Fliss, M; Sanchez-Cespedes, M; Mazzarelli, P; Rinaldi, M; Nicol, T; Gabrielson, E; Cuomo, C; Cohen, D; Pandit, S; Spencer, M; Rabitti, C; Fazio, V M; Sidransky, D

    2001-10-15

    To determine the frequency and distribution of mitochondrial DNA mutations in breast cancer, 18 primary breast tumors were analyzed by direct sequencing. Twelve somatic mutations not present in matched lymphocytes and normal breast tissues were detected in 11 of the tumors screened (61%). Of these mutations, five (42%) were deletions or insertions in a homopolymeric C-stretch between nucleotides 303-315 (D310) within the D-loop. The remaining seven mutations (58%) were single-base substitutions in the coding (ND1, ND4, ND5, and cytochrome b genes) or noncoding regions (D-loop) of the mitochondrial genome. In three cases (25%), the mutations detected in coding regions led to amino acid substitutions in the protein sequence. We then screened an additional 46 primary breast tumors with a rapid PCR-based assay to identify poly-C alterations in D310, and we found seven more cancers with alterations. Using D310 mutations as clonal marker, we detected identical changes in five of five matched fine-needle aspirates and in four of four metastases-positive lymph nodes. The high frequency of D310 alterations in primary breast cancer combined with the high sensitivity of the PCR-based assays provides a new molecular tool for cancer detection.

  8. Association between Breast Cancer Recurrence and Cellular Dissociation Assessed Using Fine-Needle Aspiration.

    PubMed

    Koike, Etsuko; Iwaya, Keiichi; Watanabe, Akinori; Miyake, Shinji; Sato, Eiichi; Ishikawa, Takashi

    2016-01-01

    To determine the associations between breast cancer recurrence and cytological findings of fine-needle aspiration cytology (FNAC). The study included 117 women who had undergone a modified radical mastectomy for invasive ductal carcinoma of the breast. FNAC samples of these patients were reexamined, and cytological findings, such as cellular dissociation, nuclear pleomorphism, nuclear atypia, chromatin pattern, and nuclear size, were scored. Uni- and multivariate analyses were performed to determine the prognostic significance of the cytological findings. Corresponding cancer tissues were immunostained for estrogen receptor, progesterone receptor, human epidermal growth factor 2 (HER2), p53, and E-cadherin to determine their associations with cytological findings. Coexpression of Arp2 and WAVE2 was also examined immunohistochemically as a cell locomotion signal. Cellular dissociation (p = 0.0259) and nuclear size (p = 0.0417) were significantly associated with cancer recurrence. Multivariate analysis showed that cellular dissociation and histological grade were significant independent predictors of cancer recurrence. Cellular dissociation was found to be associated with coexpression of Arp2 and WAVE2 (p = 0.0356) and HER2 (p = 0.0469). The cytological finding of cell dissociation was associated with the activation of Arp2 and WAVE2 signals and was an independent predictor of recurrence. © 2016 S. Karger AG, Basel.

  9. Fine needle aspiration cytology of radiation-induced changes in nonneoplastic breast lesions. Possible pitfalls in cytodiagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterse, J.L.; Thunnissen, F.B.; van Heerde, P.

    1989-03-01

    The range of radiation-induced changes in fine needle aspiration (FNA) smears of the breast is described. In 41 of more than 800 patients who underwent breast-conserving treatment, a palpable breast lesion developed, and FNA was performed. In six cases, a recurrent carcinoma was present. In the remaining cases, three patterns of nonneoplastic lesions could be discerned: epithelial atypia (14 cases), fat necrosis (10 cases) and poorly cellular smears without epithelial atypia or fat necrosis (13 cases). It is important to be familiar with the patterns of radiation-induced epithelial atypia, since such atypia may lead to a misdiagnosis of recurrent carcinoma.more » These atypical cells may show impressive anisocytosis and anisonucleosis; however, the nuclear/cytoplasmic ratio remains normal and an admixture of bipolar cells is present. Cell dissociation and necrotic cell debris, as often seen in breast cancer smears, were never encountered in FNA smears from radiated nonneoplastic breasts.« less

  10. Malignant nodular hidradenoma on the scalp: report of a case with fine needle aspiration cytology features and histologic correlation.

    PubMed

    Garcia-Bonafe, María Magdalena; Campins, Maria M Company; Redecilla, Pere Huguet

    2009-01-01

    Malignant nodular hidradenoma (MNH) is a malignant adnexal tumor of the eccrine sweat glands. The histology is similar to that of benign nodular hidradenoma, but MNH shows an infiltrative and invasive pattern, necrosis and angiolymphatic invasion. A 60-year-old woman, diagnosed with rectal adenocarcinoma 6 months before, underwent fine needle aspiration (FNA) of a nodule on the scalp. The aspirate smears showed (1) necrotic debris; (2) cohesive cell clusters and tissue fragments; (3) tubular formations; (4) globoid or cylindrical clear cells; (5) cells showing dense cytoplasm and a basaloid appearance; (6) cell sheets with anaplasia and squamous differentiation; and (7) multinucleated giant cells. The histology showed a lobulated pattern with necrosis and cyst formation. The clear cells that were seen on cytology occupied the periphery of the lobules, whereas the anaplastic cells were located in the central portion. Squamous differentiation and tubular formations were observed. Rapid, accurate diagnosis of these tumors is important, particularly when they develop at sites where a metastatic process must be ruled out. Cytology of FNA material provides this capability.

  11. Comparison of incision and drainage against needle aspiration for the treatment of breast abscess.

    PubMed

    Naeem, Muhammad; Rahimnajjad, Muhammad Kazim; Rahimnajjad, Nasir Ali; Ahmed, Qazi Jalaluddin; Fazel, Pyar Ali; Owais, Muhammad

    2012-11-01

    We aim to compare the incision and drainage against ultrasound-guided aspiration for the treatment of breast abscesses. Sixty-four patients were randomly allocated to Group A (incision and drainage) and Group B (needle aspiration). Incision and drainage was done under general, whereas aspiration was done under local anesthesia with antibiotic coverage after the pus sample was taken for cultures. Time taken to resolve symptoms including point tenderness, erythema and hyperthermia, recurrence of breast abscess, and healing time was recorded. Patients were followed until 8 weeks. Culture and sensitivity of the pus were done. Data were analyzed in SPSS 16.0. The mean difference of healing time was significant (P = 0.001). A total of 93.3 per cent were healed in Group B and 76.6 per cent in Group A (P = 0.033). Twenty-two samples (34.37%) had no bacterial yield and the remaining 42 samples (65.6%) yielded 11 anaerobic cultures (17.18%) and 31 aerobic cultures (48.4%). Ultrasound-guided aspiration of breast abscesses with the judicious use of antibiotics is a better treatment modality than incision and drainage.

  12. Current status of fine needle aspiration for thyroid nodules.

    PubMed

    Ogilvie, Jennifer B; Piatigorsky, Eli J; Clark, Orlo H

    2006-01-01

    When not to perform fine needle aspiration of a thyroid nodule In summary, FNA of thyroid nodules has become one of the most useful, safe, and accurate tools in the diagnosis of thyroid pathology. Thyroid nodules that should be considered for FNA include any firm, palpable, solitary nodule or nodule associated with worrisome clinical features (rapid growth, attachment to adjacent tissues, new hoarseness, or palpable lymphadenopathy). FNA should also be performed on nodules with suspicious ultrasonographic features (microcalcifications, rounded shape, predominantly solid composition); dominant or atypical nodules in multinodular goiter; complex or recurrent cystic nodules; or any nodule associated with palpable or ultrasonographically abnormal cervical lymph nodes. Finally, FNA should be performed on any abnormal-appearing or palpable cervical lymph nodes. The management of thyroid nodules based on FNA findings is summarized in Table 2. It can be argued that in certain circumstances the results of thyroid FNA do not change the surgical management of a thyroid nodule, and thus preoperative FNA may be unnecessary. These cases include solitary nodules in patients who have a strong family history of thyroid cancer, multiple endocrine neoplasia type II, or radiation to the head and neck. These patients when they have thyroid nodules have at least a 40% risk for thyroid cancer and frequent multifocal or bilateral disease and should undergo total thyroidectomy with or without central neck lymph node dissection. Patients who have multinodular goiter and compressive symptoms, patients who have Graves disease and a thyroid nodule, or patients who have large (greater than 4 cm) or symptomatic unilateral thyroid nodules could also be considered for total thyroidectomy or lobectomy as indicated without preoperative FNA. Finally, patients who have a solitary hyperfunctioning nodule on radioiodine scan and a suppressed TSH have an extremely low incidence of malignancy and may be

  13. Cloned foal derived from in vivo matured horse oocytes aspirated by the short disposable needle system

    PubMed Central

    Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun

    2015-01-01

    Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology PMID:26119166

  14. Solitary thyroid metastasis from colon cancer: fine-needle aspiration cytology and molecular biology approach.

    PubMed

    Onorati, M; Uboldi, P; Bianchi, C L; Nicola, M; Corradini, G M; Veronese, S; Fascì, A I; Di Nuovo, F

    2015-01-01

    Thyroid gland is one of the most vascularized organs of the body, nevertheless clinical and surgical series report an incidence of secondary malignancies in this gland of only 3%. Colorectal carcinoma metastatic to the thyroid gland is not as uncommon as previously believed, infact the number of cases seems to be increased in recent years due to the more frequent use of fine-needle aspiration cytology (FNAC) guided by ultrasonography. Although kidney, breast and lung metastases to the thyroid are frequent, metastasis from colon cancer is clinically rare with 52 cases reported in the literature in the last 5 decades and three cases described as solitary thyroid metastasis from the colon cancer without any other visceral metastases. To the best of our knowledge, we report the fourth case of solitary, asymptomatic thyroid metastasis from colon cancer without involvement of other organs. We discuss the importance of FNAC to detect metastatazing process as a compulsory step of the diagnostic and therapeutic management algorithm, combined with a molecular biology approach. A review of the last 5 decades literature, to update the number of cases described to date, is also included.

  15. Analysis of false results in a series of 835 fine needle aspirates of breast lesions.

    PubMed

    Willis, S L; Ramzy, I

    1995-01-01

    To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.

  16. Methods specification for diagnostic test accuracy studies in fine-needle aspiration cytology: a survey of reporting practice.

    PubMed

    Schmidt, Robert L; Factor, Rachel E; Affolter, Kajsa E; Cook, Joshua B; Hall, Brian J; Narra, Krishna K; Witt, Benjamin L; Wilson, Andrew R; Layfield, Lester J

    2012-01-01

    Diagnostic test accuracy (DTA) studies on fine-needle aspiration cytology (FNAC) often show considerable variability in diagnostic accuracy between study centers. Many factors affect the accuracy of FNAC. A complete description of the testing parameters would help make valid comparisons between studies and determine causes of performance variation. We investigated the manner in which test conditions are specified in FNAC DTA studies to determine which parameters are most commonly specified and the frequency with which they are specified and to see whether there is significant variability in reporting practice. We identified 17 frequently reported test parameters and found significant variation in the reporting of these test specifications across studies. On average, studies reported 5 of the 17 items that would be required to specify the test conditions completely. A more complete and standardized reporting of methods, perhaps by means of a checklist, would improve the interpretation of FNAC DTA studies.

  17. Ultrasound-Guided Fine-Needle Aspiration of Non-palpable and Suspicious Axillary Lymph Nodes with Subsequent Removal after Tattooing: False-Negative Results and Concordance with Sentinel Lymph Nodes.

    PubMed

    Kim, Won Hwa; Kim, Hye Jung; Jung, Jin Hyang; Park, Ho Yong; Lee, Jeeyeon; Kim, Wan Wook; Park, Ji Young; Cheon, Hyejin; Lee, So Mi; Cho, Seung Hyun; Shin, Kyung Min; Kim, Gab Chul

    2017-11-01

    Ultrasonography-guided fine-needle aspiration (US-guided FNA) for axillary lymph nodes (ALNs) is currently used with various techniques for the initial staging of breast cancer and tagging of ALNs. With the implementation of the tattooing of biopsied ALNs, the rate of false-negative results of US-guided FNA for non-palpable and suspicious ALNs and concordance with sentinel lymph nodes were determined by node-to node analyses. A total of 61 patients with breast cancer had negative results for metastasis on US-guided FNA of their non-palpable and suspicious ALNs. The biopsied ALNs were tattooed with an injection of 1-3 mL Charcotrace (Phebra, Lane Cove West, Australia) ink and removed during sentinel lymph node biopsy or axillary dissection. We determined the rate of false-negative results and concordance with the sentinel lymph nodes by a retrospective review of surgical and pathologic findings. The association of false-negative results with clinical and imaging factors was evaluated using logistic regression. Of the 61 ALNs with negative results for US-guided FNA, 13 (21%) had metastases on final pathology. In 56 of 61 ALNs (92%), tattooed ALNs corresponded to the sentinel lymph nodes. Among the 5 patients (8%) without correspondence, 1 patient (2%) had 2 metastatic ALNs of 1 tattooed node and 1 sentinel lymph node. In multivariate analysis, atypical cells on FNA results (odds ratio = 20.7, p = 0.040) was independently associated with false-negative FNA results. False-negative ALNs after US-guided FNA occur at a rate of 21% and most of the tattooed ALNs showed concordance with sentinel lymph nodes. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Artificial neural network in breast lesions from fine-needle aspiration cytology smear.

    PubMed

    Subbaiah, R M; Dey, Pranab; Nijhawan, Raje

    2014-03-01

    Artificial neural networks (ANNs) are applied in engineering and certain medical fields. ANN has immense potential and is rarely been used in breast lesions. In this present study, we attempted to build up a complete robust back propagation ANN model based on cytomorphological data, morphometric data, nuclear densitometric data, and gray level co-occurrence matrix (GLCM) of ductal carcinoma and fibroadenomas of breast cases diagnosed on fine-needle aspiration cytology (FNAC). We selected 52 cases of fibroadenomas and 60 cases of infiltrating ductal carcinoma of breast diagnosed on FNAC by two cytologists. Essential cytological data was quantitated by two independent cytologists (SRM, PD). With the help of Image J software, nuclear morphomeric, densitometric, and GLCM features were measured in all the cases on hematoxylin and eosin-stained smears. With the available data, an ANN model was built up with the help of Neurointelligence software. The network was designed as 41-20-1 (41 input nodes, 20 hidden nodes, 1 output node). The network was trained by the online back propagation algorithm and 500 iterations were done. Learning was adjusted after every iteration. ANN model correctly identified all cases of fibroadenomas and infiltrating carcinomas in the test set. This is one of the first successful composite ANN models of breast carcinomas. This basic model can be used to diagnose the gray zone area of the breast lesions on FNAC. We assume that this model may have far-reaching implications in future. Copyright © 2013 Wiley Periodicals, Inc.

  19. Use of a thin-layer technique in thyroid fine needle aspiration.

    PubMed

    Malle, Despoina; Valeri, Rosalia-Maria; Pazaitou-Panajiotou, Kalliopi; Kiziridou, Anastasia; Vainas, Iraklis; Destouni, Charicleia

    2006-01-01

    To investigate the efficacy of the ThinPrep Processor (Cytyc Corporation, Boxborough, Massachusetts, U.S.A) in fine needle aspiration (FNA) of thyroid gland lesions. This study included 459 thyroid FNA specimens obtained from patients who came to our endocrinology department with various thyroid disorders over 3 years. The cytologic material was prepared using both the conventional and ThinPrep method in the first 2 years (285 cases), while in the last one only the ThinPrep method was used (1 74 cases). The smears were stained using a modified Papanicolaou procedure and May-Grünwald-Giemsa stain. Immunocytochemistry was performed on thin-layer slides using specific monoclonal antibodies when needed. Thin-layer and direct smear diagnoses were compared with the final cytologic or histologic diagnoses, when available. Our cases included 279 adenomatoid nodules, 15 cases of Hashimoto thyroiditis, 45 follicular neoplasms, 14 Hürthle cell tumors, 58 papillary carcinomas and 1 5 anaplastic carcinomas. Thin-layer preparations showed a trend toward a lower proportion of inadequate specimens and a lower false negative rate. Cytomorphologic features showed some differences between the 2 methods. Colloid was less frequently observed on ThinPrep slides, while nuclear detail and micronucleoli were more easily detected with this technique. Moreover, ThinPrep appeared to be the appropriate method for the use of ancillary techniques in suspicious cases. Thin-layer cytology improves the diagnostic accuracy of thyroid FNA and offers the possibility of performing new techniques, such as immunocytochemistry, on the same sample in order to detect malignancy as well as the type and origin of thyroid gland neoplasms.

  20. Fine needle aspiration in the diagnosis and classification of hepatoblastoma: Analysis of 21 New Cases.

    PubMed

    Vlajnic, Tatjana; Brisse, Hervé J; Aerts, Isabelle; Fréneaux, Paul; Cellier, Cécile; Fabre, Monique; Klijanienko, Jerzy

    2017-02-01

    Diagnosis of hepatoblastoma (HBL) is based on characteristic clinical and radiological presentation, young age and marked elevation of serum α-fetoprotein (aFP). Fine needle aspiration (FNA) technique is successfully used in the diagnosis of hepatoblastoma. To evaluate the value of FNA in the diagnosis and subtyping of HBL, we report our experience correlated to histological sections (core needle biopsy, CNB). From 1991 to 2015, 21 cases from 20 patients were cytologically diagnosed as HBL. The patients were 15 males and 5 females, mean age being 3 years, and median age being 2 years and 4 months. Serum aFP levels ranged from negative to 1,285,000 ng/ml. We defined cytological criteria to diagnose fetal, embryonal, mesenchymal, and small cell undifferentiated components. The accurate cytological diagnosis of HBL was made in all cases; 8 cases exhibited a single component and 13 cases exhibited two or more components. Fetal and embryonal components were seen in 18 and 13 cases, respectively, and small cell undifferentiated component was seen in one case. Mesenchymal component was seen in 12 cases. Comparing cytology and histology, identical components were identified on both, FNA and CNB in 14 cases. When analyzing only the presence of epithelial components, 17 cases were concordant in both techniques. FNA allows to accurately diagnose HBL and recognize its histological subtypes. On the basis of high concordance between cytological and histological diagnosis, FNA is validated as an alternative diagnostic method to CNB. Diagn. Cytopathol. 2017;45:91-100. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Fine-Needle Aspiration of Metastatic Central Type Primitive Neuroectodermal Tumors in Patients with a Germ Cell Tumor.

    PubMed

    Chen, Shaoxiong; Idrees, Muhammad; Lin, Jingmei; Wu, Howard H

    2017-01-01

    Central type primitive neuroectodermal tumors (PNET) are some of the most frequent somatic type tumors derived from germ cell tumors and can metastasize. We studied the cytomorphological features of metastatic central type PNET by fine-needle aspiration (FNA). A computerized search of our laboratory information system was performed for the 9-year period from 2005 through 2014 to identify all cytology cases in which a diagnosis of metastatic central type PNET had been rendered. A total of 5 FNA cases were collected and direct smears were reexamined. All patients had a history of testicular or ovarian germ cell tumors. Direct smears displayed single and clusters of atypical round to oval cells with scant to moderate cytoplasm. Abundant naked nuclei were present in Diff-Quik-stained smears with mild to marked crushed artifacts and nuclear molding. Tumor cells showed fine granular chromatin, nuclear size variation (up to 1:3), and one or more small nucleoli. Pseudorosettes (Homer Wright-like rosette) were noticed in 1 case. Tumor cells were commonly positive for synaptophysin. Metastatic PNET can be reliably diagnosed by FNA. Differential diagnoses include Ewing sarcoma/peripheral PNET, alveolar rhabdomyosarcoma, neuroblastoma, etc. It is important to be familiar with this entity to avoid diagnostic pitfalls. © 2017 S. Karger AG, Basel.

  2. Artificial neural network model to distinguish follicular adenoma from follicular carcinoma on fine needle aspiration of thyroid.

    PubMed

    Savala, Rajiv; Dey, Pranab; Gupta, Nalini

    2018-03-01

    To distinguish follicular adenoma (FA) and follicular carcinoma (FC) of thyroid in fine needle aspiration cytology (FNAC) is a challenging problem. In this article, we attempted to build an artificial neural network (ANN) model from the cytological and morphometric features of the FNAC smears of thyroid to distinguish FA from FC. The cytological features and morphometric analysis were done on the FNAC smears of histology proven cases of FA (26) and FC (31). The cytological features were analysed semi-quantitatively by two independent observers (RS and PD). These data were used to make an ANN model to differentiate FA versus FC on FNAC material. The performance of this ANN model was assessed by analysing the confusion matrix and receiving operator curve. There were 39 cases in training set, 9 cases each in validation and test sets. In the test group, ANN model successfully distinguished all cases (9/9) of FA and FC. The area under receiver operating curve was 1. The present ANN model is efficient to diagnose follicular adenoma and carcinoma cases on cytology smears without any error. In future, this ANN model will be able to diagnose follicular adenoma and carcinoma cases on thyroid aspirate. This study has immense potential in future. This is an open ended ANN model and more parameters and more cases can be included to make the model much stronger. © 2017 Wiley Periodicals, Inc.

  3. Pulmonary metastases of recurrent intracranial hemangiopericytoma diagnosed on fine needle aspiration cytology: a case report.

    PubMed

    Goel, Deepa; Babu, Sasidhara; Prayaga, Aruna K; Sundaram, Challa

    2008-01-01

    Meningeal hemangiopericytoma (HPC) is a rare neoplasm. It is closely related to hemangiopericytomas in systemic tissues, with a tendency to recur and metastasize outside the CNS. Only a few case reports describe the cytomorphologic appearance of these metastasizing lesions, most having primary tumor in deep soft tissues. We report a case of recurrent meningeal HPC metastasizing to lungs. A 48-year-old woman presented with a history of headache. She underwent primary surgery 10 years previously for left parietal tumor. Histopathologic diagnosis was HPC. Radiotherapy was given postoperatively. Brain magnetic resonance imaging (MRI) at admission suggested local recurrence. She also complained of dry cough and shortness of breath. On evaluation, computed tomography (CT) scan lung showed multiple, bilateral, small nodules. Fine needle aspiration cytology (FNAC) of a larger nodule revealed spindle-shaped cells arranged around blood vessels. Immunohistochemistry with CD34 on cell block confirmed metastatic HPC. FNAC is an easy, accurate, relatively noninvasive procedure for diagnosing metastases, especially in patients with a history of recurrent intracranial HPC. Immunohistochemistry on cell block material collected at the time of FNAC may aid in distinguishing HPC from other tumors that are close mimics cytologically.

  4. Service Quality Of Diagnostic Fine Needle Aspiration Cytology In A Tertiary Care Hospital Of Lahore (Process Measure As Patient's Perspective).

    PubMed

    Rizvi, Zainab; Usmani, Rabia Arshed; Rizvi, Amna; Wazir, Salim; Zahra, Taskeen; Rasool, Hafza

    2017-01-01

    Quality of any service is the most important aspect for the manufacturer as well as the consumer. The primary objective of any nation's health system is to provide supreme quality health care services to its patients. The objective of this study was to assess the quality of diagnostic fine needle aspiration cytology service in a tertiary care hospital. As Patient's perspectives provide valuable information on quality of process, therefore, patient's perception in terms of satisfaction with the service was measured. In this cross sectional analytical study, 291 patients undergoing fine needle aspiration cytology in Mayo Hospital were selected by systematic sampling technique. Information regarding satisfaction of patients with four dimensions of service quality process, namely "procedure, sterilization, conduct and competency of doctor" was collected through interview on questionnaire. The questionnaire was developed on SERVQUAL model, a measurement tool, for quality assessment of services provided to patients. All items were assessed on 2- point likert scale (0=dissatisfied, 1=satisfied). Frequencies and percentages of satisfied and dissatisfied patients were recorded for each item and all items in each dimension were scored. If the percentage of sum of all item scores of a dimension was ≥60, the dimension was 'good quality'. Whereas <60% was 'poor quality' dimension. Data was analysed using epi-info-3.5.1. Fisher test was applied to check statistical significance. (p-value <0.05). Out of the 4 dimensions of service quality process, Procedure (48.8%), Sterilization (51.5%) and practitioner conduct (50.9%) were perceived as 'poor' by the patients. Only practitioner competency (67.4%) was perceived as 'good'. Comparison of dimensions of service quality scoring with overall level of patient satisfaction revealed that all 4 dimensions were significantly related to patient dissatisfaction (p<.05). The study suggests that service quality of therapeutic and diagnostic

  5. Metastasis of colon cancer to the thyroid gland: a case diagnosed on fine-needle aspirate by a combined cytological, immunocytochemical, and molecular approach.

    PubMed

    Cozzolino, Immacolata; Malapelle, Umberto; Carlomagno, Chiara; Palombini, Lucio; Troncone, Giancarlo

    2010-12-01

    Fine-needle aspiration (FNA) with cytological evaluation reliably diagnoses primary and secondary thyroid neoplasms. However, identifying the primary origin of a metastatic process involving the thyroid gland is challenging. In particular, metastasis of colon cancer to the thyroid gland is very rare. In this case report, a right lobe solid thyroid nodule in a 66-year-old male was aspirated. FNA cytology showed necrosis and atypical tall columnar cells; since, the patient at age 60 had undergone surgery for a sigmoid-rectal cancer metastasizing to the liver and subsequently to the lung, a suspicion of metastasis from colon cancer was raised. This was corroborated by cell-block immunocytochemistry showing a cytokeratin (CK) 7 negative/CK20-positive staining pattern; thyreoglobulin and TTF-1 were both negative. Since KRAS codon 12/13 mutations frequently occur in colon cancer, whereas they are extremely uncommon in primary thyroid tumors, DNA was extracted from the aspirated cells, and KRAS mutational analysis was carried out. The codon 12 G12D mutation was found; the same mutation was evident in the primary cancer of the colon and in its liver and lung metastasis. Thus, a combined cytological, immunocytochemical and molecular approach unquestionably correlated metastatic adenocarcinoma cells aspirated from the thyroid to a colo-rectal origin. © 2010 Wiley-Liss, Inc.

  6. Presenting hydrothorax predicts failure of needle aspiration in primary spontaneous pneumothorax.

    PubMed

    Wu, Kwok Kei; Lui, Chun Tat; Ho, Chik Leung; Tsui, Kwok Leung; Fung, Hin Tat

    2016-06-01

    The objective was to evaluate if existence of hydrothorax in initial chest radiograph predicts treatment outcome in patients with primary spontaneous pneumothorax who received needle thoracostomy. This is a retrospective cohort study carried out from January 2011 to August 2014 in 1 public hospital in Hong Kong. All consecutive adult patients aged 18years or above who attended the emergency department with the diagnosis of primary spontaneous pneumothorax with needle aspiration performed as primary treatment were included. Age, smoking status, size of pneumothorax, previous history of pneumothorax, aspirated gas volume and presence of hydropneumothorax in initial radiograph were included in the analysis. The outcome was success or failure of the needle aspiration. Logistic regression was used to identify the predicting factors of failure of needle aspiration. There were a total of 127 patients included. Seventy-three patients (57.5%) were successfully treated with no recurrence upon discharge. Among 54 failure cases, 13 patients (10.2%) failed immediately after procedure as evident by chest radiograph and required second treatment. Forty-one patients (32.3%) failed upon subsequent chest radiographs. Multivariate logistic regression showed factors independently associated with the failure of needle aspiration, which included hydropneumothorax in the initial radiograph (odds ratio [OR]=4.47 [1.56i12.83], P=.005), previous history of pneumothorax (OR=3.92 [1.57-9.79], P=.003), and large size of pneumothorax defined as apex-to-cupola distance ≥5cm (OR=2.75 [1.21-6.26], P=.016). Hydropneumothorax, previous history of pneumothorax, and large size were independent predictors of failure of needle aspiration in treatment of primary spontaneous pneumothorax. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Flexible needle with integrated optical coherence tomography probe for imaging during transbronchial tissue aspiration

    NASA Astrophysics Data System (ADS)

    Li, Jiawen; Quirk, Bryden C.; Noble, Peter B.; Kirk, Rodney W.; Sampson, David D.; McLaughlin, Robert A.

    2017-10-01

    Transbronchial needle aspiration (TBNA) of small lesions or lymph nodes in the lung may result in nondiagnostic tissue samples. We demonstrate the integration of an optical coherence tomography (OCT) probe into a 19-gauge flexible needle for lung tissue aspiration. This probe allows simultaneous visualization and aspiration of the tissue. By eliminating the need for insertion and withdrawal of a separate imaging probe, this integrated design minimizes the risk of dislodging the needle from the lesion prior to aspiration and may facilitate more accurate placement of the needle. Results from in situ imaging in a sheep lung show clear distinction between solid tissue and two typical constituents of nondiagnostic samples (adipose and lung parenchyma). Clinical translation of this OCT-guided aspiration needle holds promise for improving the diagnostic yield of TBNA.

  8. Application of Sal classification to parotid gland fine-needle aspiration cytology: 10-year retrospective analysis of 312 patients.

    PubMed

    Kilavuz, Ahmet Erdem; Songu, Murat; İmre, Abdulkadir; Arslanoğlu, Secil; Özkul, Yilmaz; Pinar, Ercan; Ateş, Düzgün

    2018-05-01

    The accuracy of fine-needle aspiration biopsy (FNAB) is controversial in parotid tumors. We aimed to compare FNAB results with the final histopathological diagnosis and to apply the "Sal classification" to our data and discuss its results and its place in parotid gland cytology. The FNAB cytological findings and final histological diagnosis were assessed retrospectively in 2 different scenarios based on the distribution of nondefinitive cytology, and we applied the Sal classification and determined malignancy rate, sensitivity, and specificity for each category. In 2 different scenarios FNAB sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were found to be 81%, 87%, 54.7%, and 96.1%; and 65.3%, 100%, 100%, and 96.1%, respectively. The malignancy rates and sensitivity and specificity were also calculated and discussed for each Sal category. We believe that the Sal classification has a great potential to be a useful tool in classification of parotid gland cytology. © 2018 Wiley Periodicals, Inc.

  9. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    PubMed

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  10. Needle aspiration versus intercostal tube drainage for pneumothorax in the newborn.

    PubMed

    Bruschettini, Matteo; Romantsik, Olga; Ramenghi, Luca Antonio; Zappettini, Simona; O'Donnell, Colm P F; Calevo, Maria Grazia

    2016-01-11

    Pneumothorax occurs more frequently in the neonatal period than at any other time of life and is associated with increased mortality and morbidity. It may be treated with either needle aspiration or insertion of a chest tube. The former consists of aspiration of air with a syringe through a needle or an angiocatheter, usually through the second or third intercostal space in the midclavicular line. The chest tube is usually placed in the anterior pleural space passing through the sixth intercostal space into the pleural opening, turned anteriorly and directed to the location of the pneumothorax, and then connected to a Heimlich valve or an underwater seal with continuous suction. To compare the efficacy and safety of needle aspiration and intercostal tube drainage in the management of neonatal pneumothorax. We used the standard search strategy of the Cochrane Neonatal Review group to search the Cochrane Central Register of Controlled Trials (CENTRAL 2015, Issue 11), MEDLINE via PubMed (1966 to 30 November 2015), EMBASE (1980 to 30 November 2015), and CINAHL (1982 to 30 November 2015). We also searched clinical trials databases, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. Randomised controlled trials, quasi-randomised controlled trials and cluster trials comparing needle aspiration (either with the needle or angiocatheter left in situ or removed immediately after aspiration) to intercostal tube drainage in newborn infants with pneumothorax. For each of the included trial, two authors independently extracted data (e.g. number of participants, birth weight, gestational age, kind of needle and chest tube, choice of intercostal space, pressure and device for drainage) and assessed the risk of bias (e.g. adequacy of randomisation, blinding, completeness of follow-up). The primary outcomes considered in this review are mortality during the neonatal period and during hospitalisation. One

  11. Complications associated with endobronchial ultrasound-guided transbronchial needle aspiration: a nationwide survey by the Japan Society for Respiratory Endoscopy.

    PubMed

    Asano, Fumihiro; Aoe, Motoi; Ohsaki, Yoshinobu; Okada, Yoshinori; Sasada, Shinji; Sato, Shigeki; Suzuki, Eiichi; Semba, Hiroshi; Fukuoka, Kazuya; Fujino, Shozo; Ohmori, Kazumitsu

    2013-05-10

    With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice. To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE). A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities. Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions. Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%). Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage. Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%). Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high. Since the use of EBUS-TBNA is

  12. Convolution neural networks for real-time needle detection and localization in 2D ultrasound.

    PubMed

    Mwikirize, Cosmas; Nosher, John L; Hacihaliloglu, Ilker

    2018-05-01

    We propose a framework for automatic and accurate detection of steeply inserted needles in 2D ultrasound data using convolution neural networks. We demonstrate its application in needle trajectory estimation and tip localization. Our approach consists of a unified network, comprising a fully convolutional network (FCN) and a fast region-based convolutional neural network (R-CNN). The FCN proposes candidate regions, which are then fed to a fast R-CNN for finer needle detection. We leverage a transfer learning paradigm, where the network weights are initialized by training with non-medical images, and fine-tuned with ex vivo ultrasound scans collected during insertion of a 17G epidural needle into freshly excised porcine and bovine tissue at depth settings up to 9 cm and [Formula: see text]-[Formula: see text] insertion angles. Needle detection results are used to accurately estimate needle trajectory from intensity invariant needle features and perform needle tip localization from an intensity search along the needle trajectory. Our needle detection model was trained and validated on 2500 ex vivo ultrasound scans. The detection system has a frame rate of 25 fps on a GPU and achieves 99.6% precision, 99.78% recall rate and an [Formula: see text] score of 0.99. Validation for needle localization was performed on 400 scans collected using a different imaging platform, over a bovine/porcine lumbosacral spine phantom. Shaft localization error of [Formula: see text], tip localization error of [Formula: see text] mm, and a total processing time of 0.58 s were achieved. The proposed method is fully automatic and provides robust needle localization results in challenging scanning conditions. The accurate and robust results coupled with real-time detection and sub-second total processing make the proposed method promising in applications for needle detection and localization during challenging minimally invasive ultrasound-guided procedures.

  13. Progression from on-site to point-of-care fine needle aspiration service: Opportunities and challenges

    PubMed Central

    Gupta, Prabodh K

    2010-01-01

    Background Standard-of-care requires the availability of an efficient, economical and accurate on-site fine needle aspiration (FNA) service. Presence of a trained individual during the procedure ensures an improved patient care. Appropriate selection of the equipment, interaction with the clinicians and compliance with the various regulations during the procedure is essential. This is often done by an on-site FNA service. Organization and implementation of such a system in a large academic center is challenging. Method we reviewed the ambulatory care needs in the new Perelman Center for Advanced Medicine (PeCAM). Multiple (9) FNA sites have been established keeping in view the patient's convenience, clinic demands, various regulatory requirements and laboratory staff. Each location has dedicated FNA station with microscopes and supplies. In addition, state- ofthe -art technologies including a mobile FNA cart (Penn-A- Cart), remote specimen evaluation (TeleCyP) have been incorporated. Results The new set up is extremely efficient and much valued by the patients and the clinicians. It has improved patient care. Conclusion With necessary investments and resources a point-of-care FNA service has been created which has improved patient care. This, albeit with certain modifications may serve as a model for FNA service. PMID:20607093

  14. The reliability of fine-needle aspiration biopsy in terms of malignancy in patients with Hashimoto thyroiditis.

    PubMed

    Kapan, Murat; Onder, Akin; Girgin, Sadullah; Ulger, Burak Veli; Firat, Ugur; Uslukaya, Omer; Oguz, Abdullah

    2015-02-01

    The aim of this study was to analyze the presence of malignancy in patients with Hashimoto's thyroiditis and to investigate the reliability of preoperative fine-needle aspiration biopsy (FNAB). The retrospective study included 44 patients who were operated on for nodular goiter between December 2010 and October 2011. The patients underwent thyroidectomy following a cytologic analysis plus FNAB. Hashimoto's thyroiditis was confirmed on histopathology in all patients. FNAB results were defined as benign in 14 (31.8%), suspicion for malignancy in 17 (38.6%), malignant in 9 (20.5%), and inadequate in 4 (9.1%). Following the thyroidectomy, presence of papillary thyroid carcinoma and follicular variant of papillary thyroid carcinoma were detected in 10 patients (22.7%) and 1 (2.3%) patient, respectively. The FNAB results were interpreted in terms of malignancy, which revealed the sensitivity as 80%; specificity, 40%; false positives, 69.2%; false negatives, 14.3%; positive predictive value, 31.8%; negative predictive value, 85.7%; and diagnostic accuracy, 50%. The coexistence of Hashimoto's thyroiditis with papillary thyroid carcinoma is quite common. The FNAB results for such cases are hard to evaluate, and they are likely to increase the number of false positives.

  15. Extraneural metastases of primary central nervous system tumors identified by fine needle aspiration: a retrospective analysis.

    PubMed

    Vandenbussche, Christopher J; Ho, Cheng-Ying; Nugent, Summer L; Ali, Syed Z

    2014-01-01

    Extraneural metastasis (EM) of primary central nervous system (PCNS) neoplasms is rare and signifies a poor clinical outcome. Due to its infrequent occurrence, relatively few reports on the cytomorphology of these neoplasms have been published. We describe a series of 19 cases from 16 patients at a single, large tertiary care center. A retrospective analysis of 19 cases of metastases from PCNS neoplasms identified on fine needle aspiration (FNA) in 8 male and 8 female patients aged 14-72 years (mean age 39.6) from 1989 to 2013 was conducted to further characterize the cytomorphologic features identified at metastatic sites. Six different PCNS neoplasms were identified: meningioma, glioblastoma, hemangiopericytoma (HPC), oligodendroglioma, medulloblastoma, and retinoblastoma. The mean latency period between the diagnoses of the primary and first metastatic tumors was 7.4 years (range 0-15). The most common PCNS malignancy responsible for EM was HPC. The most common metastatic sites were the lung (31%) and soft tissue/bone (31%). EM of PCNS tumors is extremely rare. FNA allows for quick, safe and accurate diagnosis. Cytomorphologic features are characteristic, and in conjunction with the clinical history and immunohistochemistry, an accurate diagnosis was obtained in 100% of the cases.

  16. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  17. Impact of fine needle aspiration (FNA) and of the number of punctures on the feline testis: clinical, gross anatomy and histological assessment.

    PubMed

    Gouletsou, Pagona G; Galatos, Apostolos D; Sideri, Aikaterini I; Kostoulas, Polychronis

    2012-07-01

    The safety of testicular fine needle aspiration (FNA) has been proven in dogs but has not been fully established in men, while studies in rats have given contradictory results. Furthermore, the extent of damage inflicted by multiple punctures is unknown. The aim of this study was to determine the impact of FNA and of the number of punctures on the feline testis with clinical, gross anatomy and histological examinations. Twenty-seven sexually mature healthy laboratory Domestic Shorthair cats were randomly assigned to two groups: 5 cats in which no FNA was performed (control group), and 22 cats which had their left and right testis punctured with a 26 ga needle towards 3 and 8 directions, respectively (experimental group). Two cats at a time were orchiectomized 5 or 30 min, 1, 2, 4, 7 or 14 days or 1, 2, 3 or 4 mo post-aspiration. The cats of the control group were also orchiectomized. During the first week post-aspiration clinical examination revealed vaginal cavity hematoma (8/44 testes), while the histological findings were focal hemorrhagic areas (20/24 testes), erythrocytes inside the seminiferous tubules' lumen (9/24 testes), and germinal cell degeneration in <1.94% of the seminiferous tubules (15/24 testes). After the first week the histological findings were germinal cell degeneration in <2.14% of the seminiferous tubules (19/20 testes) and enlargement of the lumen of <5.16% of the seminiferous tubules (7/20 testes). The germinal epithelium and interstitium had an overall normal appearance. No significant differences were observed between the left and right testis. The results of the study indicate that testicular FNA should be considered a safe procedure in the cat when up to 8 punctures are performed. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Fine-needle aspiration cytology: its origin, development, and present status with special reference to a developing country, India.

    PubMed

    Das, Dilip K

    2003-06-01

    Fine-needle aspiration cytology (FNAC) was performed on a large scale at Memorial Hospital, New York, during the 1930s, but during the ensuing years, it did not gain much encouragement in United States. The technique had a resurgence in Scandinavia during the 1950s and 1960s, where it flourished before spreading to other parts of the world. It had also a revival in the United States, which contributed enormously to this tool in each and every aspect. The status of FNA during 1966-2002 was assessed through review of MEDLINE search data on FNA and its correlation with World Bank website data on classification of countries. A total of 849 journals published 5,609 articles on FNA over a period of 37 years. Both the number of publishing journals and the number of published articles on FNA were low during the 1960s (3.5 +/- 0.58 and 4.0 +/- 0.82, respectively) and 1970s (20.3 +/- 14.72 and 25.0 +/- 20.54, respectively), but their number increased sharply from the 1980s onward (78.2 +/- 25.65 and 147.2 +/- 66.89, respectively, during the 1980s, 126.2 +/- 11.94 and 301.4 +/- 35.99, respectively, during the 1990s, and 113.3 +/- 36.46 and 287.3 +/- 85.93, respectively, during the 2000s). The difference between the decades of 1960s-2000s, with respect to the number of publishing journals and published articles, was highly significant (P < 0.0001). Only 90 (10.6%) of the journals were from the arena of pathology and its branches. The remaining journals belonged to various other disciplines of medicine; a small fraction were even from the veterinary sciences. Ten journals, including three in the field of cytopathology, published 2,448 (43.6%) of the total articles on FNA. During 1987-2002, 46 (29.7%) of the 155 developing nations published articles on FNA, whereas 28 (52.8%) of the developed (high-income economies) countries did so, the difference being highly significant (P = 0.0044). The total number of publications from high-income economies was 3,124 (195.3 per year), as

  19. Cytologic appearance of retinal cells included in a fine-needle aspirate of a meningioma around the optic nerve of a dog.

    PubMed

    Tvedten, Harold; Hillström, Anna

    2013-06-01

    A 6-year-old Wirehair Dachshund had a meningioma around the optic nerve that caused exophthalmos. A benign mesenchymal tumor was suspected based on the cytologic pattern of a fine-needle aspirate, and a meningioma was diagnosed by histopathologic examination. In addition to the meningioma cells, the cytologic smears included groups of cells from apparently 4 layers of normal retina. In particular, uniform rod-shaped structures in the cytologic sample could suggest rod-shaped bacteria, but these structures were identified as cylindrical outer segments of photoreceptor rod cells. Other retinal structures recognized included pigmented epithelial layer cells with their uniquely formed pigment granules, the characteristic bi-lobed, cleaved nuclei from the outer nuclear layer, and nerve tissue likely from the outer plexiform layer of the retina. © 2013 American Society for Veterinary Clinical Pathology.

  20. Endobronchial ultrasound-guided transbronchial needle injection for local control of recurrent non-small cell lung cancer.

    PubMed

    Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.

  1. Validation of a technique for accurate fine-wire electrode placement into posterior gluteus medius using real-time ultrasound guidance.

    PubMed

    Hodges, P W; Kippers, V; Richardson, C A

    1997-01-01

    Fine-wire electromyography is primarily utilised for the recording of activity of the deep musculature, however, due to the location of these muscles, accurate electrode placement is difficult. Real-time ultrasound imaging (RTUI) of muscle tissue has been used for the guidance of the needle insertion for the placement of electrodes into the muscles of the abdominal wall. The validity of RTUI guidance of needle insertion into the deep muscles has not been determined. A cadaveric study was conducted to evaluate the accuracy with which RTUI can be used to guide fine-wire electrode placement using the posterior fibres of gluteus medius (PGM) as an example. Pilot studies revealed that the ultrasound resolution of cadaveric tissue is markedly reduced making it impossible to directly evaluate the technique, therefore, three studies were conducted. An initial study involved the demarcation of the anatomical boundaries of PGM using RTUI to define a technique based on an anatomical landmark that was consisent with the in vivo RTUI guided needle placement technique. This anatomical landmark was then used as the guide for the cadaveric needle insertion. Once the needle was positioned 0.05 ml of dye was introduced and the specimen dissected. The dye was accurately placed in PGM in 100% of the specimens. Finally, fine-wire electrodes were inserted into the PGM of five volunteers and manoeuvres performed indicating the accuracy of placement. This study supports the use of ultrasound imaging for the accurate guidance of needle insertion for fine-wire and needle EMG electrodes.

  2. Triple Gene Analysis Using Samples Obtained by Endobronchial Ultrasound-guided Transbronchial Needle Aspiration

    PubMed Central

    Lee, Kyungjong; Um, Sang-Won; Jeong, Byeong-Ho; Yang, Jung Wook; Choi, Yoon-La; Han, Joungho; Kim, Hojoong; Kwon, O Jung

    2016-01-01

    Objective A mutational analysis of tumor tissue samples is an important part of advanced lung cancer treatment strategies. This study evaluated the efficacy of a triple gene analysis using samples obtained via endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Methods Either metastatic lymph nodes or primary lung mass samples obtained by EBUS-TBNA were collected between May 2011 and May 2013. We consecutively analyzed epidermal growth factor receptor (EGFR), V-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (KRAS), and anaplastic lymphoma kinase (ALK) fusion genes using remnant tissue samples. Results A total of 109 patients were diagnosed with non-small cell lung cancer (NSCLC). Of these, 70% were adenocarcinoma, 27% squamous cell carcinoma with NSCLC, and 3% were related to other types of lung cancer. EGFR mutations were detected in 23 cases (21.1%), KRAS mutations in 13 cases (11.9%), and ALK fusion genes in 5 cases (4.9%). The ALK fusion genes could not be analyzed in four cases because of insufficient tissue samples remaining after routine histochemistry and an EGFR/KRAS mutation analysis. We found that small biopsy samples from EBUS-TBNA were adequate for performing a triple gene analysis in 97 patients (96%). ALK fusion protein immunohistochemistry (IHC) was 100% consistent with fluorescence in situ hybridization (FISH). Conclusion Small samples obtained by EBUS-TBNA were found to be sufficient for performing a triple gene analysis following routine histology and IHC. ALK IHC showed a very good concordance with FISH for detecting ALK fusion genes. PMID:27803402

  3. Biological characteristics of HCC by ultrasound-guided aspiration biopsy and its clinical application

    PubMed Central

    Lin, Li-Wu; Lin, Xue-Ying; He, Yi-Mi; Gao, Shang-Da; Lin, Xiao-Dong

    2003-01-01

    AIM: To probe the pathological biological characteristics of hepatocellular carcinoma (HCC) by the ultrasound-guided aspiration biopsy and assess the clinical application value of this method. METHODS: The biopsy and DNA analysis by flow cytometry (FCM) were taken in 46 cases with HCC nodules, including 26 cases and 20 cases with nodules ≤ 3 cm and > 3 cm in diameters respectively, and 12 cases with intrahepatic benign hyperplastic nodules. They were taken in 22 cases of 46 cases with HCC before and after the therapy. Fine-needles and automatic histological incised biopsy needles were used. The fresh biopsy tissue was produced into the single cell suspension, which was sent for DNA detection and ratio analysis of cell period. The ratio of each DNA period of cell proliferation of each group was calculated and compared with each other. The DNA aneuploid (AN) and apoptosis cell peak were observed and their percentages were calculated. RESULTS: The ratios of S and G2/M periods of DNA, which reflect cell hyperproliferation, in the group with HCC tumors > 3 cm in diameter were markedly higher than those of the group with HCC nodules ≤ 3 cm in diameter and the group with the benign hyperplastic nodules (P < 0.01 except A:B of S period, P < 0.05). The ratios of the middle group were also apparently higher than those of the latter group (P < 0.01). The ratio of DNA AN of 46 cases with HCC nodules was 34.8% (16/46). None of the cases with the intrahepatic hyperplastic nodules appeared AN. The DNA AN appeared more apparently with the growth of the tumors. The AN ratio of the group with tumors > 3 cm in diameter was 55% (11/20), markedly higher than that of the group with tumors ≤ 3 cm in diameter which was 19.2% (5/26) (P < 0.01). The FCM DNA analysis of 22 specimens of hepatic carcinoma tissue before therapy showed that the aneuploid peaks appeared in 5 cases (22.7%). The ratio of G1 period rose after therapy while the S period and G2/M ratios fell (P < 0.01). The

  4. Comparison of ThinPrep and conventional preparations on fine needle aspiration cytology material.

    PubMed

    Dey, P; Luthra, U K; George, J; Zuhairy, F; George, S S; Haji, B I

    2000-01-01

    To compare the various cytologic features on ThinPrep 2000 (TP) (Cytyc Corporation, Marlborough, Massachusetts, U.S.A.) and conventional preparation (CP) specimens from fine needle aspiration cytology (FNAC) material by a semiquantitative scoring system. In this prospective study a total of 71 consecutive cases were included. In each case, two passes were performed. The first pass was used for conventional preparations, with direct smears made and fixed immediately in 95% alcohol for Papanicolaou stain. For TP preparation a second pass produced material for processing in the ThinPrep 2000. The TP and CP slides were studied independently by two observers and representative slides of CP and TP compared for cellularity, background blood and necrotic cell debris, cell architecture, informative background, presence of monolayer cells, and nuclear and cytoplasmic details by a semiquantitative scoring system. Statistical analysis was performed by Wilcoxon's signed rank test on an SPSS program (Chicago, Illinois, U.S.A.). TP preparations contained adequate diagnostic cells in all cases and were tangibly superior to CP preparations concerning monolayer cells, absence of blood and necrosis, and preservation of nuclear and cytoplasmic detail (statistically significant, Wilcoxon's signed rank test, P < .000). TP preparations are superior to conventional preparations with regard to clear background, monolayer cell preparation and cell preservation. It is easier and less time consuming to screen and interpret TP preparations because the cells are limited to smaller areas on clear backgrounds, with excellent cellular preservation. However, TP preparations are more expensive than CP and require some experience for interpretation.

  5. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    PubMed Central

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  6. Complications, Consequences, and Practice Patterns of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    Shah, Archan M.; Lei, Xiudong; Jimenez, Carlos A.; Morice, Rodolfo C.; Yarmus, Lonny; Filner, Joshua; Ray, Cynthia; Michaud, Gaetane; Greenhill, Sara R.; Sarkiss, Mona; Casal, Roberto; Rice, David; Ost, David E.

    2013-01-01

    Background: Few studies of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) have been large enough to identify risk factors for complications. The primary objective of this study was to quantify the incidence of and risk factors for complications in patients undergoing EBUS-TBNA. Methods: Data on prospectively enrolled patients undergoing EBUS-TBNA in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) database were extracted and analyzed for the incidence, consequences, and predictors of complications. Results: We enrolled 1,317 patients at six hospitals. Complications occurred in 19 patients (1.44%; 95% CI, 0.87%-2.24%). Transbronchial lung biopsy (TBBx) was the only risk factor for complications, which occurred in 3.21% of patients who underwent the procedure and in 1.15% of those who did not (OR, 2.85; 95% CI, 1.07-7.59; P = .04). Pneumothorax occurred in seven patients (0.53%; 95% CI, 0.21%-1.09%). Escalations in level of care occurred in 14 patients (1.06%; 95% CI, 0.58%-1.78%); its risk factors were age > 70 years (OR, 4.06; 95% CI, 1.36-12.12; P = .012), inpatient status (OR, 4.93; 95% CI, 1.30-18.74; P = .019), and undergoing deep sedation or general anesthesia (OR, 4.68; 95% CI, 1.02-21.61; P = .048). TBBx was performed in only 12.6% of patients when rapid onsite cytologic evaluation (ROSE) was used and in 19.1% when it was not used (P = .006). Interhospital variation in TBBx use when ROSE was used was significant (P < .001). Conclusions: TBBx was the only risk factor for complications during EBUS-TBNA procedures. ROSE significantly reduced the use of TBBx. PMID:23117878

  7. Is there still a role for thyroid scintigraphy in the workup of a thyroid nodule in the era of fine needle aspiration cytology and molecular testing?

    PubMed Central

    Moreno-Reyes, Rodrigo; Kyrilli, Aglaia; Lytrivi, Maria; Bourmorck, Carole; Chami, Rayan; Corvilain, Bernard

    2016-01-01

    Thyroid scintigraphy is now rarely used in the work-up of a thyroid nodule except in the presence of a low TSH value. Therefore, autonomously functioning thyroid nodules (AFTNs) with a normal TSH value are diagnosed only in the rare medical centers that continue to use thyroid scan systematically in the presence of a thyroid nodule. In this review, we discuss the prevalence of AFTN with a normal TSH level and the possible consequences of performing fine needle aspiration cytology (FNAC) in an undiagnosed AFTN. We also discuss the risk of malignant AFTN which may be higher than previously stated. PMID:27158470

  8. Effect of the time of day and queue position in the endoscopic schedule on the performance characteristics of endoscopic ultrasound-guided fine-needle aspiration for diagnosing pancreatic malignancies

    PubMed Central

    Korenblit, Jason; Tholey, Danielle M.; Tolin, Joanna; Loren, David; Kowalski, Thomas; Adler, Douglas G.; Davolos, Julie; Siddiqui, Ali A.

    2016-01-01

    Background and Objectives: Recent reports have indicated that the time of day may impact the detection rate of abnormal cytology on gynecologic cytology samples. The aim of this study was to determine if procedure time or queue position affected the performance characteristics of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosing solid pancreatic malignancies. Patients and Methods: We conducted a retrospective study evaluating patients with solid pancreatic lesions in whom EUS-FNA was performed. Three timing variables were evaluated as surrogate markers for endoscopist fatigue: Procedure start times, morning versus afternoon procedures, and endoscopy queue position. Statistical analyses were performed to determine whether the timing variables predicted performance characteristics of EUS-FNA. Results: We identified 609 patients (mean age: 65.8 years, 52.1% males) with solid pancreatic lesions who underwent EUS-FNA. The sensitivity of EUS-FNA was 100% for procedures that started at 7 AM while cases that started at 4 PM had a sensitivity of 81%. Using start time on a continuous scale, each elapsed hour was associated with a 1.9% decrease in EUS-FNA sensitivity (P = 0.003). Similarly, a 10% reduction in EUS-FNA sensitivity was detected between morning and afternoon procedures (92% vs. 82% respectively, P = 0.0006). A linear regression comparing the procedure start time and diagnostic accuracy revealed a decrease of approximately 1.7% in procedure accuracy for every hour later a procedure was started. A 16% reduction in EUS-FNA accuracy was detected between morning and afternoon procedures (100% vs. 84% respectively, P = 0.0009). When the queue position was assessed, a 2.4% reduction in accuracy was noted for each increase in the queue position (P = 0.013). Conclusion: Sensitivity and diagnostic accuracy of EUS-FNA for solid pancreatic lesions decline with progressively later EUS starting times and increasing numbers of procedures before a

  9. Digital PCR Improves Mutation Analysis in Pancreas Fine Needle Aspiration Biopsy Specimens

    PubMed Central

    Court, Colin M.; Kim, Stephen; Braxton, David R.; Hou, Shuang; Muthusamy, V. Raman; Watson, Rabindra R.; Sedarat, Alireza; Tseng, Hsian-Rong; Tomlinson, James S.

    2017-01-01

    Applications of precision oncology strategies rely on accurate tumor genotyping from clinically available specimens. Fine needle aspirations (FNA) are frequently obtained in cancer management and often represent the only source of tumor tissues for patients with metastatic or locally advanced diseases. However, FNAs obtained from pancreas ductal adenocarcinoma (PDAC) are often limited in cellularity and/or tumor cell purity, precluding accurate tumor genotyping in many cases. Digital PCR (dPCR) is a technology with exceptional sensitivity and low DNA template requirement, characteristics that are necessary for analyzing PDAC FNA samples. In the current study, we sought to evaluate dPCR as a mutation analysis tool for pancreas FNA specimens. To this end, we analyzed alterations in the KRAS gene in pancreas FNAs using dPCR. The sensitivity of dPCR mutation analysis was first determined using serial dilution cell spiking studies. Single-cell laser-microdissection (LMD) was then utilized to identify the minimal number of tumor cells needed for mutation detection. Lastly, dPCR mutation analysis was performed on 44 pancreas FNAs (34 formalin-fixed paraffin-embedded (FFPE) and 10 fresh (non-fixed)), including samples highly limited in cellularity (100 cells) and tumor cell purity (1%). We found dPCR to detect mutations with allele frequencies as low as 0.17%. Additionally, a single tumor cell could be detected within an abundance of normal cells. Using clinical FNA samples, dPCR mutation analysis was successful in all preoperative FNA biopsies tested, and its accuracy was confirmed via comparison with resected tumor specimens. Moreover, dPCR revealed additional KRAS mutations representing minor subclones within a tumor that were not detected by the current clinical gold standard method of Sanger sequencing. In conclusion, dPCR performs sensitive and accurate mutation analysis in pancreas FNAs, detecting not only the dominant mutation subtype, but also the additional rare

  10. Digital PCR Improves Mutation Analysis in Pancreas Fine Needle Aspiration Biopsy Specimens.

    PubMed

    Sho, Shonan; Court, Colin M; Kim, Stephen; Braxton, David R; Hou, Shuang; Muthusamy, V Raman; Watson, Rabindra R; Sedarat, Alireza; Tseng, Hsian-Rong; Tomlinson, James S

    2017-01-01

    Applications of precision oncology strategies rely on accurate tumor genotyping from clinically available specimens. Fine needle aspirations (FNA) are frequently obtained in cancer management and often represent the only source of tumor tissues for patients with metastatic or locally advanced diseases. However, FNAs obtained from pancreas ductal adenocarcinoma (PDAC) are often limited in cellularity and/or tumor cell purity, precluding accurate tumor genotyping in many cases. Digital PCR (dPCR) is a technology with exceptional sensitivity and low DNA template requirement, characteristics that are necessary for analyzing PDAC FNA samples. In the current study, we sought to evaluate dPCR as a mutation analysis tool for pancreas FNA specimens. To this end, we analyzed alterations in the KRAS gene in pancreas FNAs using dPCR. The sensitivity of dPCR mutation analysis was first determined using serial dilution cell spiking studies. Single-cell laser-microdissection (LMD) was then utilized to identify the minimal number of tumor cells needed for mutation detection. Lastly, dPCR mutation analysis was performed on 44 pancreas FNAs (34 formalin-fixed paraffin-embedded (FFPE) and 10 fresh (non-fixed)), including samples highly limited in cellularity (100 cells) and tumor cell purity (1%). We found dPCR to detect mutations with allele frequencies as low as 0.17%. Additionally, a single tumor cell could be detected within an abundance of normal cells. Using clinical FNA samples, dPCR mutation analysis was successful in all preoperative FNA biopsies tested, and its accuracy was confirmed via comparison with resected tumor specimens. Moreover, dPCR revealed additional KRAS mutations representing minor subclones within a tumor that were not detected by the current clinical gold standard method of Sanger sequencing. In conclusion, dPCR performs sensitive and accurate mutation analysis in pancreas FNAs, detecting not only the dominant mutation subtype, but also the additional rare

  11. Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal staging in lung cancer*

    PubMed Central

    Fernández-Bussy, Sebastián; Labarca, Gonzalo; Canals, Sofia; Caviedes, Iván; Folch, Erik; Majid, Adnan

    2015-01-01

    OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic test with a high diagnostic yield for suspicious central pulmonary lesions and for mediastinal lymph node staging. The main objective of this study was to describe the diagnostic yield of EBUS-TBNA for mediastinal lymph node staging in patients with suspected lung cancer. METHODS: Prospective study of patients undergoing EBUS-TBNA for diagnosis. Patients ≥ 18 years of age were recruited between July of 2010 and August of 2013. We recorded demographic variables, radiological characteristics provided by axial CT of the chest, location of the lesion in the mediastinum as per the International Association for the Study of Lung Cancer classification, and definitive diagnostic result (EBUS with a diagnostic biopsy or a definitive diagnostic method). RESULTS: Our analysis included 354 biopsies, from 145 patients. Of those 145 patients, 54.48% were male. The mean age was 63.75 years. The mean lymph node size was 15.03 mm, and 90 lymph nodes were smaller than 10.0 mm. The EBUS-TBNA method showed a sensitivity of 91.17%, a specificity of 100.0%, and a negative predictive value of 92.9%. The most common histological diagnosis was adenocarcinoma. CONCLUSIONS: EBUS-TBNA is a diagnostic tool that yields satisfactory results in the staging of neoplastic mediastinal lesions. PMID:26176519

  12. Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.

    PubMed

    Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S

    2014-07-01

    (1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  13. Secondary tumors involving the thyroid gland: A multi-institutional analysis of 28 cases diagnosed on fine-needle aspiration.

    PubMed

    HooKim, Kim; Gaitor, Jennifer; Lin, Oscar; Reid, Michelle D

    2015-11-01

    Fine-needle aspiration (FNA) is routinely used to evaluate primary thyroid lesions (PTLs), however, its role in diagnosing secondary thyroid neoplasms (STNs) has not been extensively studied. The goal was to examine the clinical and cytopathologic features of STNs diagnosed on FNA. The clinico-pathologic features of 28 STNs were analyzed. All PTLs, lymphomas, and locally invasive tumors were excluded. There were 28 STNs (0.18% incidence) out of 15,800 thyroid FNAs (12 males, 16 females, 32 - 85 years), all occurring metachronously (3 weeks-20 years, average 78.3 months) comprising 24 (85.7%) metastatic carcinomas (14 [50%] renal; 4 [14.3%] head and neck squamous cell carcinomas, 3 [10.7%] breast, and 1 [3.6%] colorectal, uterine serous carcinoma, and lung adenosquamous carcinoma, respectively), 3 sarcomas (10.7%) and 1 melanoma (3.6%). STNs are rare and diverse tumors which may occur decades after primary malignancy. Renal carcinomas are the most common. Prior history of malignancy, high index of suspicion, and attention to key distinguishing cytologic clues are critical for accurate diagnosis. © 2015 Wiley Periodicals, Inc.

  14. Brief reports: regional anesthesia needles can introduce ultrasound gel into tissues.

    PubMed

    Belavy, David

    2010-09-01

    Anesthesiologists may insert needles through ultrasound gel when performing ultrasound-guided regional anesthesia. In this study, it was determined whether needles carry gel into tissues. Ultrasound gel dyed blue was applied to pork rashers. Tuohy and short-bevel needles were passed through the gel and pork. The needles were then assessed for the presence of ultrasound gel. All needles, including those with stylets, carried gel and tissue within the lumen. Ultrasound gel may be injected around (and perhaps in) nerves during regional anesthesia procedures. Studies are needed to determine the implications of this practice.

  15. Next-generation sequencing for molecular diagnosis of lung adenocarcinoma specimens obtained by fine needle aspiration cytology

    NASA Astrophysics Data System (ADS)

    Qiu, Tian; Guo, Huiqin; Zhao, Huan; Wang, Luhua; Zhang, Zhihui

    2015-06-01

    Identification of multi-gene variations has led to the development of new targeted therapies in lung adenocarcinoma patients, and identification of an appropriate patient population with a reliable screening method is the key to the overall success of tumor targeted therapies. In this study, we used the Ion Torrent next-generation sequencing (NGS) technique to screen for mutations in 89 cases of lung adenocarcinoma metastatic lymph node specimens obtained by fine-needle aspiration cytology (FNAC). Of the 89 specimens, 30 (34%) were found to harbor epidermal growth factor receptor (EGFR) kinase domain mutations. Seven (8%) samples harbored KRAS mutations, and three (3%) samples had BRAF mutations involving exon 11 (G469A) and exon 15 (V600E). Eight (9%) samples harbored PIK3CA mutations. One (1%) sample had a HRAS G12C mutation. Thirty-two (36%) samples (36%) harbored TP53 mutations. Other genes including APC, ATM, MET, PTPN11, GNAS, HRAS, RB1, SMAD4 and STK11 were found each in one case. Our study has demonstrated that NGS using the Ion Torrent technology is a useful tool for gene mutation screening in lung adenocarcinoma metastatic lymph node specimens obtained by FNAC, and may promote the development of new targeted therapies in lung adenocarcinoma patients.

  16. Differentiating benign from malignant thyroid nodules using micro ribonucleic acid amplification in residual cells obtained by fine needle aspiration biopsy.

    PubMed

    Mazeh, Haggi; Levy, Yair; Mizrahi, Ido; Appelbaum, Liat; Ilyayev, Nadia; Halle, David; Freund, Herbert R; Nissan, Aviram

    2013-04-01

    Fine needle aspiration biopsy (FNAB) is the most commonly used diagnostic tool to differentiate benign from malignant thyroid nodules. Nevertheless, some FNAB cytology results are not definite. In such cases diagnostic thyroid lobectomy is performed with malignancy rate on final histopathology ranging at 15%-75%. The aim of this study was to improve on the accuracy of FNAB-based cytology by amplification of microRNAs (micro ribonucleic acids [miRs]) from the residual cells left in the FNAB needle after submission for cytology. Residual cells were collected from the needle cup after FNAB cytology of 77 consecutive patients with thyroid nodules. miR-enriched RNA was extracted for all patients with cytology showing either follicular lesion or suspicion for malignancy (n=11). The expression of miR-21, -31, -146b, -187, -221, and -222 was determined using real-time polymerase chain reaction. Results were compared with final surgical histopathology. RNA was successfully extracted from all FNAB specimens. Five patients had FNAB cytology suspicious for malignancy. The miR panel was positive in all five (100%). Six patients had follicular lesions on FNAB. The miR panel was positive in three of four patients (75%) with confirmed malignancy and was negative in two of two (0%) patients with benign pathology results. This corresponded to a specificity of 100%, sensitivity of 88%, and accuracy of 90%. RNA extraction from FNAB residual cells is feasible, and a miR panel amplified from the extracted RNA seems like a promising diagnostic tool in this limited number of patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Rapid on-site assessment of specimens by biomedical scientists improves the quality of head and neck fine needle aspiration cytology.

    PubMed

    Breeze, J; Poller, D N; Gibson, D; Tilley, E A; Cooke, L; Soar, E; Repanos, C

    2014-10-01

    Immediate rapid on-site assessment (ROSA) of fine needle aspiration cytology (FNAC) specimens by biomedical scientists (BMS), the UK equivalent of cytotechnologists, or by pathologists may improve specimen quality and cellular adequacy rates for lymph node, head and neck and thyroid FNAC. The aim of this study was to evaluate the effect of introducing ROSA by BMS in an outpatient clinic setting. The adequacy rate and sensitivity of histological diagnosis for lymph node, thyroid and salivary gland FNAC samples were determined before and after the introduction of BMS ROSA. The additional financial costs and time required to perform this service were also estimated. Thirty-one patients underwent ultrasound (US)-guided FNAC with ROSA and 151 without. ROSA reduced the number of FNAC insufficient in quality for diagnosis from 43% to 19% (P = 0.0194). The estimated additional cost for pathology per patient for ROSA was between £52.05 and £70.74, equivalent to €65.40/US $83.90 and €88.89/US $114.0, respectively, an increase of between 28% and 49% from the original cost. ROSA necessitated an additional 6 minutes clinic time per patient, reducing the number of patients that could be seen in an average clinic from 13 to 10 as well as requiring increased laboratory time for FNAC slide assessment. ROSA by suitably trained biomedical scientists and with appropriate consultant pathologist support can improve the quality of FNAC sampling for head and neck lesions. Although ROSA resulted in both additional financial and time costs, these are more than likely to be offset by a reduction in patients returning to clinic for repeat FNAC or undergoing unnecessary surgery. © 2013 John Wiley & Sons Ltd.

  18. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara; Ferro, Carlo

    2011-02-15

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsymore » of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.« less

  19. Fine needle aspiration biopsy of three cases of squamous cell carcinoma presenting as a thyroid mass: cytological findings and differential diagnosis.

    PubMed

    Rosa, M; Toronczyk, K

    2012-02-01

    Primary squamous cell carcinomas of the thyroid gland are extremely rare, comprising about 1% of thyroid malignancies. Although squamous cell carcinomas are readily identified as such on aspiration cytology in the majority of cases, the differentiation of primary versus metastatic tumour might not always be easy. Herein, we report three cases of squamous cell carcinomas involving the thyroid gland. Fine needle aspiration cytology (FNAC) was performed in three patients with a thyroid mass using standard guidelines. Smears were stained with Diff-Quik and Papanicolaou stains. Two patients were male and one was female, aged 59, 45 and 35 years, respectively. In all three patients a thyroid mass was present. FNAC smears in all cases showed cytological features of squamous cell carcinoma including keratinization and necrosis. After clinical and cytological correlation, one case appeared to be primary, one case metastatic, and in the third case no additional clinical information or biopsy follow-up was available for further characterization. Because primary squamous cell carcinoma of the thyroid is a rare finding, metastatic squamous cell carcinoma should always be excluded first. Metastatic disease usually presents in the setting of widespread malignancy, therefore a dedicated clinical and radiological investigation is necessary in these cases. In both clinical scenarios the patient's prognosis is poor. © 2010 Blackwell Publishing Ltd.

  20. Molecular testing in lung cancer: fine-needle aspiration specimen adequacy and test prioritization prior to the CAP/IASLC/AMP Molecular Testing Guideline publication.

    PubMed

    Rafael, Oana C; Aziz, Mohamed; Raftopoulos, Harry; Vele, Oana E; Xu, Weisheng; Sugrue, Chiara

    2014-06-01

    Subtyping of lung carcinoma with immunohistochemistry is essential for diagnosis, whereas molecular testing (MT) is required for therapy guidance. In the current study, the authors report on MT performed on fine-needle aspiration specimens at the study institution over a 2-year period preceding the April 2013 College of American Pathologists (CAP)/International Association for the Study of Lung Cancer (IASLC)/Association for Molecular Pathology (AMP) Molecular Testing Guideline (MTG) publication. The database of the study institution was retrospectively queried for cases of lung and thoracic/lower cervical lymph node fine-needle aspiration specimens for 2011 through 2012. Of 246 selected cases, 26 featured a limited amount of material in cell blocks. MT increased significantly between 2011 and 2012 and was requested in 39.4% of cases (97 of 246 cases): 86 of those cases had at least 1 MT result and 11 had insufficient material for any MT. Anaplastic lymphoma kinase (ALK) testing was performed in 9 cases in which DNA was insufficient for epidermal growth factor receptor (EGFR) testing. In addition, 13 cases of adenocarcinoma/non-small cell lung carcinoma had at least 1 MT canceled because of insufficient DNA, but at the same time had an average of 3.46 immunohistochemical stains performed. Of all the cytology specimens, 10.6% featured limited material; however, no universally accepted testing sequence priority was available at the time the study was performed. As per the MTG, MT should take precedence over immunohistochemistry in cases of adenocarcinoma/non-small cell lung carcinoma. Approximately 5.3% of the specimens in the current study had insufficient material for MT while having multiple stains performed instead. The MTG also recommend performing EGFR before ALK testing; the authors found 9 cases with insufficient material for EGFR testing that had ALK testing performed. The results of the current study underscore the need for a testing prioritization

  1. Preservation of Fine-Needle Aspiration Specimens for Future Use in RNA-Based Molecular Testing

    PubMed Central

    Ladd, Amy C.; O'Sullivan-Mejia, Emerald; Lea, Tasha; Perry, Jessica; Dumur, Catherine I.; Dragoescu, Ema; Garrett, Carleton T.; Powers, Celeste N.

    2015-01-01

    Background The application of ancillary molecular testing is becoming more important for the diagnosis and classification of disease. The use of fine-needle aspiration (FNA) biopsy as the means of sampling tumors in conjunction with molecular testing could be a powerful combination. FNA is minimally invasive, cost effective, and usually demonstrates accuracy comparable to diagnoses based on excisional biopsies. Quality control (QC) and test validation requirements for development of molecular tests impose a need for access to pre-existing clinical samples. Tissue banking of excisional biopsy specimens is frequently performed at large research institutions, but few have developed protocols for preservation of cytologic specimens. This study aimed to evaluate cryopreservation of FNA specimens as a method of maintaining cellular morphology and ribonucleic acid (RNA) integrity in banked tissues. Methods FNA specimens were obtained from fresh tumor resections, processed by using a cryopreservation protocol, and stored for up to 27 weeks. Upon retrieval, samples were made into slides for morphological evaluation, and RNA was extracted and assessed for integrity by using the Agilent Bioanalyzer (Agilent Technologies, Santa Clara, Calif). Results Cryopreserved specimens showed good cell morphology and, in many cases, yielded intact RNA. Cases showing moderate or severe RNA degradation could generally be associated with prolonged specimen handling or sampling of necrotic areas. Conclusions FNA specimens can be stored in a manner that maintains cellular morphology and RNA integrity necessary for studies of gene expression. In addition to addressing quality control (QC) and test validation needs, cytology banks will be an invaluable resource for future molecular morphologic and diagnostic research studies. PMID:21287691

  2. DIAGNOSIS OF ENDOCRINE DISEASE: High-yield thyroid fine-needle aspiration cytology: an update focused on ancillary techniques improving its accuracy.

    PubMed

    Bongiovanni, M; Trimboli, P; Rossi, E D; Fadda, G; Nobile, A; Giovanella, L

    2016-02-01

    Thyroid fine-needle aspiration (FNA) cytology is a fast growing field. One of the most developing areas is represented by molecular tests applied to cytological material. Patients that could benefit the most from these tests are those that have been diagnosed as 'indeterminate' on FNA. They could be better stratified in terms of malignancy risk and thus oriented with more confidence to the appropriate management. Taking in to consideration the need to improve and keep high the yield of thyroid FNA, professionals from various fields (i.e. molecular biologists, endocrinologists, nuclear medicine physicians and radiologists) are refining and fine-tuning their diagnostic instruments. In particular, all these developments aim at increasing the negative predictive value of FNA to improve the selection of patients for diagnostic surgery. These advances involve terminology, the application of next-generation sequencing to thyroid FNA, the use of immunocyto- and histo-chemistry, the development of new sampling techniques and the increasing use of nuclear medicine as well as molecular imaging in the management of patients with a thyroid nodule. Herein, we review the recent advances in thyroid FNA cytology that could be of interest to the 'thyroid-care' community, with particular focus on the indeterminate diagnostic category. © 2016 European Society of Endocrinology.

  3. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    NASA Astrophysics Data System (ADS)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  4. Thyroid Fine Needle Aspiration Biopsies in Children: Study of Cytological-Histological Correlation and Immunostaining with Thyroid Peroxidase Monoclonal Antibodies

    PubMed Central

    Hoperia, Victoria; Larin, Alexander; Jensen, Kirk; Bauer, Andrew; Vasko, Vasily

    2010-01-01

    Context. There is limited data comparing results of fine needle aspiration biopsies (FNABs) to histological diagnosis in children. Design. FNABs were performed in 707 children and cytological results were compared to histology in 165 cases. The usefulness of immunostaining with anti-TPO monoclonal antibodies (MoAb47) on FNAB samples was examined in 54 operated patients. Results. Among unsatisfactory, benign, suspicious, and malignant FNAB, the histological diagnoses were benign in 12/12 (100%), 69/70 (98.5%), 40/50 (80.0%), and 0/33 (0%), respectively. After surgery, malignancy was established in 44/165 (26.6%) cases. The sensitivity, specificity, and positive and negative predictive values were 95.4%, 55.8%, 61.7%, and 95% with standard FNAB; and 100%, 75%, 73.3, and 100% with MoAb47. Among suspicious FNAB, positive MoAb47 staining was a reliable marker for exclusion of malignancy. Conclusion. Benign and malignant FNAB accurately predict histological diagnosis. In suspicious FNAB, MoAb47 immunostaining may be a useful adjunct to standard cytology. PMID:20652042

  5. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    NASA Astrophysics Data System (ADS)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  6. Pistol-grip Syringe holder (Cameco syringe pistol) in fine needle aspiration Biopsy: any advantages over the use of direct finger grip?

    PubMed

    Mayun, A A; Nggada, H A; Abdulazzez, J O; Musa, A B; Pindiga, U H; Khalil, M I

    2013-06-01

    The study seeks to determine the advantages of using the pistol-grip syringe holder in the performance of FNAB over the use of direct finger grip method. The skin is cleaned with gauze soaked in methylated spirit and the lump is located and firmly held between the thumb and fore finger of the free hand. The syringe is held by the out side of the barrel or by pistol-grip, and the needle tip pushed into the lesion. The plunger is partially retracted, creating a negative pressure. The cutting edge of the needle tip frees the cells inside the lesion which are sucked into the fine bore of the needle. The contents of the needle are then emptied on a microscopic slide and thinly smeared. The slides are then fixed in alcohol and later stained. These were examined under the microscope and a comparison between the aspirations using pistol-grip and direct finger grip was made. A total of 266 cases of FNABs were carried out from 1st January to 31st December, 2008. There were 89 breast cases out of which 42 (47%) had pistol-grip method and 47 (53%) had direct finger grip method; 74 thyroid cases out of which 28 (38%) were pistol-grip and 46 (62%) were direct finger grip cases; 56 cases of lymph node FNABs of which 18(32%) and 38 (68%) had pistol-grip and direct finger grip methods respectively. There were 23 cases of salivary gland FNABs having 8 (35%) and 15 (65%) as pistol-grip and direct finger grip methods respectively. Marked cellularity was observed in the majority of cases using both methods of FNABs. This study has shown that the use of pistol-grip syringe holder in the performance of FNABs has no significant advantage compared to the direct finger grip method.

  7. Catering to millennial learners: assessing and improving fine-needle aspiration performance.

    PubMed

    Rowse, Phillip G; Ruparel, Raaj K; AlJamal, Yazan N; Abdelsattar, Jad M; Heller, Stephanie F; Farley, David R

    2014-01-01

    Fine-needle aspiration (FNA) of a palpable cervical lymph node is a straightforward procedure that should be safely performed by educated general surgery (GS) trainees. Retention of technical skill is suspect, unless sequential learning experiences are provided. However, voluntary learning experiences are no guarantee that trainees will actually use the resource. A 3-minute objective structured assessment of technical skill-type station was created to assess GS trainee performance using FNA. Objective criteria were developed and a checklist was generated (perfect score = 24). Following abysmal performance of 11 postgraduate year (PGY)-4 trainees on the FNA station of our semiannual surgical skills assessment ("X-Games"), we provided all GS residents with electronic access to a 90-second YouTube video clip demonstrating proper FNA technique. PGY-2 (n = 11) and PGY-3 (n = 10) residents subsequently were tested on FNA technique 5 and 12 days later, respectively. All 32 trainees completed the station in less than 3 minutes. Overall scores ranged from 4 to 24 (mean = 14.9). PGY-4 residents assessed before the creation of the video clip scored lowest (range: 4-18, mean = 11.4). PGY-3 residents (range: 10-22, mean = 17.8) and PGY-2 residents (range: 10-24, mean = 15.8) subsequently scored higher (p < 0.05). Ten residents admitted watching the 90-second FNA video clip and scored higher (mean = 21.7) than the 11 residents that admitted they did not watch the clip (mean = 13.1, p < 0.001). Of the 11 trainees who did not watch the video, 6 claimed they did not have time, and 5 felt it would not be useful to them. Overall performance of FNA was poor in 32 midlevel GS residents. However, a 90-second video clip demonstrating proper FNA technique viewed less than 2 weeks before the examination significantly elevated scores. Half of trainees given the chance to learn online did not take the opportunity to view the video clip. Although preemptive learning is effective, future

  8. ThinPrep versus conventional smear cytologic preparations in the analysis of thyroid fine-needle aspiration specimens.

    PubMed

    Biscotti, C V; Hollow, J A; Toddy, S M; Easley, K A

    1995-08-01

    Paired fine-needle aspiration specimens were analyzed from 41 surgically resected thyroid nodules, to compare diagnostic accuracy, amount (absent, mild, moderate, or marked) and pattern (diffuse, droplets, or both) of colloid, nuclear detail (poor, satisfactory, or excellent) and cytoplasmic detail (intact or disrupted) in ThinPrep (TP) (Cytyc, Marlborough, MA) versus conventional smear (CS) cytologic preparations. The 41 surgical specimens included 25 colloid nodules, 6 papillary carcinomas, 4 follicular adenomas, 2 minimally invasive (encapsulated) follicular carcinomas, 3 Hashimoto's thyroiditis, and 1 Grave's disease. Both techniques identified seven of the eight carcinomas with the minimally invasive follicular carcinomas categorized as hypercellular follicular nodule, possibly malignant (HCFN). One papillary carcinoma was classified as a HCFN by both TP and CS techniques. The four follicular adenomas were classified as HCFN based on the TP slides. One oxyphilic follicular adenoma, associated with focal lymphocytic thyroiditis, was misinterpreted as Hashimoto's thyroiditis on a conventional smear. Three colloid nodules were interpreted as HCFN based on the TP slides. Two of these were similarly classified based on the conventional smear. ThinPrep slides contained less colloid and the colloid occurred as droplets rather than a diffuse pattern. TP slides had better nuclear detail but more often disrupted cytoplasm. In conclusion, the TP process does alter some cellular features; however, we experienced similar diagnostic accuracy with the TP and conventional smear preparations.

  9. [Fine-needle aspiration (FNA) of the thyroid gland : Analysis of discrepancies between cytological and histological diagnoses].

    PubMed

    Dalquen, P; Rashed, B; Hinsch, A; Issa, R; Clauditz, T; Luebke, A; Lüttges, J; Saeger, W; Bohuslavizki, K H

    2016-09-01

    Diagnostic problems of thyroid cytology are frequently discussed, but relevance and causes of discrepant cytological and histological diagnoses are rarely studied in detail. Investigation of causes and relevance of discrepant diagnoses. The analysis includes 297 patients who had thyroid resection after prior fine needle aspiration (FNA) and is based on the cytological and histological reports. In special cases, cytological and histological specimens were re-examined. Malignant tumors were found in 45 patients (15.1 %). In 5 patients the cytological diagnosis was "false negative". Three of these 5 tumors were papillary carcinomas (PTC) of ≤10 mm, one an obviously nonmalignant papillary proliferation of the thyroidal epithelium and one a malignant lymphoma complicating autoimmune thyreoiditis (AIT). In 11 of the 35 patients with a FNA diagnosis "suspicious of malignancy" or "malignant," 1 AIT, 4 goiter nodules, and 6 adenomas were diagnosed histologically. However, since distinct nuclear atypia was found in three of five false positive diagnoses, there still remains doubt in their benignity. Carcinomas of ≤10 mm incidentally detected in the resected thyroid tissue may not be relevant to the patient and do not reduce the high negative predictive value of FNA. The final diagnosis on the resected tissue should include the cytological findings. Discrepant findings should be commented in the report to the clinician.

  10. CD 99 immunocytochemistry in solid pseudopapillary tumor of pancreas: A study on fine-needle aspiration cytology smears.

    PubMed

    Ghosh, Ranajoy; Mallik, Saumya R; Mathur, Sandeep R; Iyer, Venkateswaran K

    2013-07-01

    Solid pseudopapillary tumor of pancreas (SPTP) is a rare pancreatic tumor of uncertain histogenesis usually affecting young women. Though these tumors have characteristic cytomorphology, it is sometimes difficult to differentiate them from neuroendocrine tumors of the pancreas. We reviewed cases of SPTP to delineate the diagnostic cytological features and also observed utility of CD 99 (MIC 2) immunostaining to aid in the diagnosis of this tumor. This study was designed to demonstrate the utility of CD 99 immunostaining along with cytological features for making a pre-operative diagnosis and delineating it from the neuroendocrine tumor of pancreas which is a close mimic. Cytomorphological features of 11 cases of solid pseudopapillary neoplasm diagnosed by pre-operative fine-needle aspiration cytology (FNAC) at our institute were reviewed. Immunocytochemistry for CD 99 was also performed on the smears. All the cases had cellular smears with monomorphic cells lying singly, as loosely cohesive clusters as well as forming delicate pseudopapillae. Presence of intra and extra-cellular basement membrane material, background foamy macrophages and nuclear grooves were the other salient features. Immunocytochemistry for CD 99 could be performed on eight cases and demonstrated typical paranuclear dot-like positivity. Pre-operative early diagnosis of SPTP can be made by FNAC which can further be aided by CD 99 immunocytochemistry.

  11. Multiple squamous cells in thyroid fine needle aspiration: Friends or foes?

    PubMed

    Gage, Heather; Hubbard, Elizabeth; Nodit, Laurentia

    2016-08-01

    Abundant squamous cells are rarely encountered in thyroid FNA with only few case reports noted in the literature. Their presence and cytologic features may pose a diagnostic dilemma and challenges for proper classification and follow-up. We intend to gain more insight into the frequency of this finding and its clinical significance. Our electronic records were searched over 16 years to reveal 15 thyroid FNAs with abundant squamous cells. The available cytology and surgical resection slides were reviewed and radiologic records and clinical follow-up was documented. Only 15 out of 8811 thyroid FNAs from our department contained predominantly squamous cells (0.17%) of which two were interpreted as nondiagnostic, four as atypical, eight as benign, and one malignant. Surgical follow-up was available in eight cases only with benign lesions representing the majority of the cases (squamous metaplasia in Hashimoto thyroiditis, benign epidermoid/branchial cleft or thyroglossal duct cysts, and one case squamous cell carcinoma). The cases without surgical resection were stable on subsequent ultrasound studies. Thyroid aspirates with predominance of squamous cells cannot be classified in the current Bethesda categories. Even when interpreted as atypical or equivocal, the squamous cells present in our small case series were mostly benign. The only malignant case was easily identified cytologically because of its higher degree of differentiation. The most common pitfall for atypical squamous cells in these aspirates was squamous metaplasia in the setting of Hashimoto thyroiditis and degenerative changes. Diagn. Cytopathol. 2016;44:676-681. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Fine-Needle Aspiration Biopsy of the Lymph Node: A Novel Tool for the Monitoring of Immune Responses after Skin Antigen Delivery.

    PubMed

    Tatovic, Danijela; Young, Philippa; Kochba, Efrat; Levin, Yotam; Wong, F Susan; Dayan, Colin M

    2015-07-01

    Assessment of immune responses in lymph nodes (LNs) is routine in animals, but rarely done in humans. We have applied minimally invasive ultrasound-guided fine-needle aspiration of the LN to a before-and-after study of the immune response to intradermally delivered Ag in healthy volunteers (n = 25). By comparison with PBMCs from the same individual, LN cells (LNCs) were characterized by reduced numbers of effector memory cells, especially CD8(+) TEMRA cells (3.37 ± 1.93 in LNCs versus 22.53 ± 7.65 in PBMCs; p = 0.01) and a marked increased in CD69 expression (27.67 ± 7.49 versus 3.49 ± 2.62%, LNCs and PBMCs, respectively; p < 0.0001). At baseline, there was a striking absence of IFN-γ ELISPOT responses to recall Ags (purified protein derivative, Tetanus toxoid, or flu/EBV/CMV viral mix) in LN, despite strong responses in the peripheral blood. However, 48 h after tuberculin purified protein derivative administration in the ipsilateral forearm resulting in a positive skin reaction, a clear increase in IFN-γ ELISPOT counts was seen in the draining LN but not in PBMCs. This response was lost by 5 d. These data suggest that the low levels of effector memory cells in the LN may explain the low background of baseline ELISPOT responses in LNs as compared with PBMCs, and the appearance of a response after 48 h is likely to represent migration of effector memory cells from the skin to the LN. Hence, it appears that the combination of intradermal Ag administration and draining LN sampling can be used as a sensitive method to probe the effector memory T cell repertoire in the skin. Copyright © 2015 by The American Association of Immunologists, Inc.

  13. Therapeutic aspects of endoscopic ultrasound

    NASA Astrophysics Data System (ADS)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  14. Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

    PubMed

    Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie

    2018-04-01

    To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.

  15. Fine needle aspiration cytology of oral and oropharyngeal lesions with an emphasis on the diagnostic utility and pitfalls.

    PubMed

    Gupta, Nalini; Banik, Tarak; Rajwanshi, Arvind; Radotra, Bishan D; Panda, Naresh; Dey, Pranab; Srinivasan, Radhika; Nijhawan, Raje

    2012-01-01

    This study was undertaken to evaluate the diagnostic utility and pitfalls of fine needle aspiration cytology (FNAC) in oral and oropharyngeal lesions. This was a retrospective audit of oral and oropharyngeal lesions diagnosed with FNAC over a period of six years (2005-2010). Oral/oropharyngeal lesions [n=157] comprised 0.35% of the total FNAC load. The age ranged 1-80 years with the male: female ratio being 1.4:1. Aspirates were inadequate in 7% cases. Histopathology was available in 73/157 (46.5%) cases. Palate was the most common site of involvement [n=66] followed by tongue [n=35], buccal mucosa [n=18], floor of the mouth [n=17], tonsil [n=10], alveolus [n=5], retromolar trigone [n=3], and posterior pharyngeal wall [n=3]. Cytodiagnoses were categorized into infective/inflammatory lesions and benign cysts, and benign and malignant tumours. Uncommon lesions included ectopic lingual thyroid and adult rhabdomyoma of tongue, and solitary fibrous tumor (SFT), and leiomyosarcoma in buccal mucosa. A single false-positive case was dense inflammation with squamous cells misinterpreted as squamous cell carcinoma (SCC) on cytology. There were eight false-negative cases mainly due to sampling error. One false-negative case due to interpretation error was in a salivary gland tumor. The sensitivity of FNAC in diagnosing oral/oropharyngeal lesions was 71.4%; specificity was 97.8% with diagnostic accuracy of 87.7%. Salivary gland tumors and squamous cell carcinoma (SCC) are the most common lesions seen in the oral cavity. FNAC proves to be highly effective in diagnosing the spectrum of different lesions in this region. Sampling error is the main cause of false-negative cases in this region.

  16. Topical topic: value of fine needle aspiration biopsy in childhood rhabdomyosarcoma: twenty-six years of experience in Slovenia.

    PubMed

    Pohar-Marinsek, Ziva; Anzic, Jozica; Jereb, Berta

    2002-06-01

    Chemotherapy (Cht) for rhabdomyosarcoma (RMS) given before local treatment can prevent mutilating surgery and high-dose irradiation (RT). Fine needle aspiration biopsy (FNAB) can confirm the diagnosis and neoadjuvant treatment can start without delay. The purpose of our study was to assess the role of FNAB in the management of childhood RMS in Slovenia. A total of 78 children and young adults were included. FNAB provided the pre-treatment diagnosis in 37 and surgical biopsy in 41 patients. In 61 cases recurrent/metastatic disease was aspirated. Cytological diagnoses were compared to the original histological diagnoses. All case histories, cytological and histological material were reviewed and immunocytochemical staining performed when necessary. FNAB provided a correct diagnosis of malignancy in all 37 primary tumours, a specific diagnosis of RMS was given in 29 (78%). With the use of immunocytochemistry during the last 15 years, the accuracy has risen to 87%. FNAB provided the diagnosis of recurrence/metastasis in 57/61 cases. No complications of FNAB were noted. Review of histology reclassified five original diagnoses of RMS into one malignant rhabdoid tumour and four sarcomas NOS. In review of cytology we were able to sub classify 80% of RMS. FNAB is a safe method, which enables us to establish the pre-treatment diagnosis of RMS, and to some extent even its type, without delay. In our study, FNAB successfully replaced surgical biopsy in 87% of RMS patients during the last 15 years. Neoadjuvant Cht was started immediately, surgery was delayed and more conservative. Consequently, the risk for treatment sequelae was considerably reduced. Copyright 2002 Wiley-Liss, Inc.

  17. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    PubMed

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (p<0.001). There were no differences in the proportion of histologic core (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  18. The yield of adequate and conclusive fine-needle aspiration results in thyroid nodules is uniform across functional and goiter types.

    PubMed

    Liel, Y

    1999-01-01

    Relatively little is known about the cytological characteristics of hyperfunctioning (hot) thyroid nodules. Concern has been expressed that fine-needle aspiration (FNA) identifies hot nodules as follicular tumors or indeterminate, and as a consequence patients could be unnecessarily referred for surgery. Between 1979 and 1996, thyroid FNA was performed on 829 patients. Result of thyroid scan was available in 326; 69 (21%) patients had hot, and 257 (79%) had warm or cold thyroid nodules. Nodules in each of these major groups were divided into 2 subgroups: clinically solitary nodules and dominant nodules in multinodular goiters (MNG). The frequencies of adequate versus inadequate FNA samples, and of conclusive versus indeterminate FNA results were determined separately for each of the groups and subgroups. In addition, patients with hot nodules and overt hyperthyroidism were identified and evaluated separately. Bivariate analyses were performed for the frequency of adequate versus inadequate smears and conclusive versus indeterminate results between hot, toxic, and cold-warm nodules, and between solitary nodules and MNG. The frequency of adequate aspirations and conclusive results in the various groups and subgroups was found to be statistically indistinguishable. In conclusion, the yield of adequate samples and the rate of conclusive results of FNA in thyroid nodules is similar, irrespective of the functional state or of goiter presentation. Hot thyroid nodules do not seem to produce an increase in the rate of inadequate or indeterminate FNA results, and therefore, do not affect the overall performance of thyroid FNA.

  19. An automated spring-loaded needle for endoscopic ultrasound-guided abdominal paracentesis in cancer patients

    PubMed Central

    Suzuki, Rei; Irisawa, Atsushi; Bhutani, Manoop S; Hikichi, Takuto; Takagi, Tadayuki; Shibukawa, Goro; Sato, Ai; Sato, Masaki; Ikeda, Tsunehiko; Watanabe, Ko; Nakamura, Jun; Annangi, Srinadh; Tasaki, Kazuhiro; Obara, Katsutoshi; Ohira, Hiromasa

    2014-01-01

    AIM: To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS: The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS: We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION: EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation. PMID:24567793

  20. Endobronchial ultrasound-guided transbronchial needle aspiration: performance of biomedical scientists on rapid on-site evaluation and preliminary diagnosis.

    PubMed

    Schacht, M J; Toustrup, C B; Madsen, L B; Martiny, M S; Larsen, B B; Simonsen, J T

    2016-10-01

    Rapid on-site evaluation (ROSE) of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) followed by a subsequent preliminary adequacy assessment and a preliminary diagnosis, was performed at Aarhus University Hospital by biomedical scientists (BMS). The aim of this study was to evaluate the BMS accuracy of ROSE adequacy assessment, the preliminary adequacy assessment and the preliminary diagnosis as compared with the cytopathologist-rendered final adequacy assessment and final diagnosis. The BMS-rendered assessments for 717 sites from 319 consecutive patients over a 4-month period were compared with the cytopathologist-rendered assessments. Comparisons of adequacy and preliminary diagnoses were based on inter-observer Cohen's Kappa coefficient with a 95% confidence interval (CI). Strong correlations between ROSE and final adequacy assessments [Kappa coefficient of 0.90 (CI: 0.85-0.96)] and between the preliminary and final adequacy assessments [Kappa coefficient of 0.93 (CI: 0.87-0.99)] were found. As for the correlation between the preliminary and final diagnoses, the Kappa coefficient was 0.99 (CI: 0.98-1). Both ROSE and preliminary adequacy assessments as well as preliminary diagnoses, all performed by BMS, were highly accurate when compared with the final assessment by the cytopathologist. © 2016 John Wiley & Sons Ltd.

  1. THE RESULTS OF PARATHYROID HORMONE ASSAY IN PARATHYROID ASPIRATES IN PRE-OPERATIVE LOCALIZATION OF PARATHYROID ADENOMAS FOR FOCUSED PARATHYROIDECTOMY IN PATIENTS WITH NEGATIVE OR SUSPICIOUS TECHNETIUM-99M-SESTAMIBI SCANS.

    PubMed

    Ozderya, Aysenur; Temizkan, Sule; Cetin, Kenan; Ozugur, Sule; Gul, Aylin Ege; Aydin, Kadriye

    2017-09-01

    This study aimed to evaluate the results of parathyroid hormone (PTH) assay in parathyroid aspirates to determine uniglandular disease by an endocrinologist-performed ultrasound (US) in patients with discordant or negative technetium-sestamibi scans and to evaluate whether this procedure increases the number of focused parathyroidectomies (FPs). We analyzed the data of 65 patients who underwent an endocrinologist-performed US-guided parathyroid fine-needle aspiration (FNA) with PTH wash-out, retrospectively. The results of PTH wash-out procedure and the reports of parathyroid surgery and pathology were reviewed. Of 65 patients, 54 had positive PTH wash-out results. The median serum PTH level of patients with positive and negative PTH wash-out results was 143 (25 and 75% interquartile range [IQR], 114 to 197) versus 154 (IQR, 115 to 255) pg/mL (P = .45), and the median PTH in FNA was 3,533 (IQR, 1,481 to 3,534) versus 6.0 (IQR, 1 to 6) pg/mL (P<.001), respectively. Forty-five patients underwent surgery. Of the operated patients, 42 had positive PTH wash-out results and had successful FP. Four patients with redo surgery had positive PTH wash-out results and were successfully re-operated with FP. Of 11 patients with negative PTH wash-out results, 3 had bilateral neck exploration (BNE) surgery and 2 patients were successfully operated, while surgery was unsuccessful in 1 patient, despite BNE. Our study results suggest that endocrinologist-performed US and parathyroid FNA with PTH wash-out increases the number and success of FPs. In particular, patients with redo surgery may benefit from this procedure. 4D-CT = four-dimensional computed tomography BNE = bilateral neck exploration FNA = fine-needle aspiration FNAB = fine-needle aspiration biopsy FP = focused parathyroidectomy IQR = 25 and 75% inter-quartile range PHPT = primary hyperparathyroidism PPV = positive predictive value PTH = parathyroid hormone 99m Tc = technetium US = ultrasound.

  2. The cost-effectiveness of fine-needle aspiration cytology and 14-gauge core needle biopsy compared with open surgical biopsy in the diagnosis of breast carcinoma.

    PubMed

    Logan-Young, W; Dawson, A E; Wilbur, D C; Avila, E E; Tomkiewicz, Z M; Sheils, L A; Laczin, J A; Taylor, A S

    1998-05-15

    Judicious utilization of fine-needle aspiration cytology (FNAC) and 14-gauge core needle biopsy (CB) theoretically should result in greater accuracy in breast carcinoma diagnosis and fewer unnecessary open surgical biopsies (OSBs), thus lowering health care costs. In 1995 in Rochester, New York, the ratio of open surgical breast biopsies per each verified breast carcinoma (OSB/Ca) in a freestanding breast clinic (EWBC) was compared with the OSB/Ca ratio of all physicians in the remainder of the city. The EWBC differs from all other diagnostic facilities in Rochester in that it routinely performs FNAC and CB. The EWBC recommended 462 OSBs resulting in 310 verified carcinomas, for a OSB/Ca ratio of 1.5. The physicians in the remainder of the city recommended 2036 OSBs resulting in 513 verified carcinomas, for a OSB/Ca ratio of 4.0. If the EWBC OSB/Ca ratio had been identical to the remainder of the city, the number of extra OSBs recommended by the clinic would have been 778, resulting in an additional cost of $1,712,082. When the added cost of the 2594 FNACs ($256,285) and 403 CBs ($252,278) performed by the clinic was subtracted from the $1,712,082, the freestanding breast clinic cost savings was $1,203,519. The lymph node metastasis rate of 19% for the breast carcinomas diagnosed in clinic patients was identical to that of the women with breast carcinoma in the remainder of the city. Utilization of FNAC and CB allows radiologists to lower their OSB/Ca ratio without sacrificing early detection. In this study, these less expensive procedures result in lowered medical costs for the health care system.

  3. Thyroglobulin assay in fluids from lymph node fine needle-aspiration washout: influence of pre-analytical conditions.

    PubMed

    Casson, Florence Boux de; Moal, Valérie; Gauchez, Anne-Sophie; Moineau, Marie-Pierre; Sault, Corinne; Schlageter, Marie-Hélène; Massart, Catherine

    2017-04-01

    The aim of this study was to evaluate the pre-analytical factors contributing to uncertainty in thyroglobulin measurement in fluids from fine-needle aspiration (FNA) washout of cervical lymph nodes. We studied pre-analytical stability, in different conditions, of 41 samples prepared with concentrated solutions of thyroglobulin (FNA washout or certified standard) diluted in physiological saline solution or buffer containing 6% albumin. In this buffer, over time, no changes in thyroglobulin concentrations were observed in all storage conditions tested. In albumin free saline solution, thyroglobulin recovery rates depended on initial sample concentrations and on modalities of their conservation (in conventional storage tubes, recovery mean was 56% after 3 hours-storage at room temperature and 19% after 24 hours-storage for concentrations ranged from 2 to 183 μg/L; recovery was 95%, after 3 hours or 24 hours-storage at room temperature, for a concentration of 5,656 μg/L). We show here that these results are due to non-specific adsorption of thyroglobulin in storage tubes, which depends on sample protein concentrations. We also show that possible contamination of fluids from FNA washout by plasma proteins do not always adequately prevent this adsorption. In conclusion, non-specific adsorption in storage tubes strongly contributes to uncertainty in thyroglobulin measurement in physiological saline solution. It is therefore recommended, for FNA washout, to use a buffer containing proteins provided by the laboratory.

  4. Interphase cytogenetics of prostatic carcinoma in fine needle aspirate smears of radical prostatectomy specimens: A practical screening tool?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, R.Y.; Troncoso, P.; El-Naggar, A.K.

    1994-09-01

    Identification of chromosomal aberrations that may be used for diagnostic or prognostic evaluation of prostatic adenocarcinoma has been the subject of great interest. In a previous study, we applied the fluorescence in situ hybridization (FISH) method on paraffin-embedded material to show that trisomy 7 was associated with the progression of human prostate cancer. In this study, we attempted to assess the utility of the FISH technique in detecting aneuploidy in fine needle aspirate (FNA) smears of prostatic tissues and to compare FISH results with that of DNA flow cytometry (FCM). Paired samples of normal and tumor FNA smears were obtainedmore » from 10 radical prostatectomy specimens. Dual-color chromosomes 7 and 9-specific centromeric DNA probes were used for FISH. FISH analysis demonstrated increased frequencies of trisomy 7 cells in all 10 tumors studied when compared with the paired normals. In contrast, 6 of 10 tumors were determined to be diploid by FCM. Our results show that FNA of radical prostatectomy specimens is a practical method for obtaining suitable material for both FISH and FCM analyses of prostate carcinoma. Thus, interphase FISH may be a practical screening tool to determine aneuploidy in FNA smears of prostatic carcinoma.« less

  5. The use of light-emitting diode fluorescence to diagnose mycobacterial lymphadenitis in fine-needle aspirates from children

    PubMed Central

    van Wyk, A. C.; Marais, B. J.; Warren, R. M.; van Wyk, S. S.; Wright, C. A.

    2011-01-01

    SUMMARY BACKGROUND Fine-needle aspiration biopsy (FNAB) is a simple, safe and effective method for investigating suspected mycobacterial lymphadenitis in children. Fluorescence microscopy can provide rapid mycobacterial confirmation. Light-emitting diodes (LEDs) provide a cheap and robust excitation light source, making fluorescence microscopy feasible in resource-limited settings. OBJECTIVE To compare the diagnostic performance of LED fluorescence microscopy on Papanicolaou (PAP) stained smears with the conventional mercury vapour lamp (MVL). METHODS FNAB smears routinely collected from palpable lymph nodes in children with suspected mycobacterial disease were PAP-stained and evaluated by two independent microscopists using different excitatory light sources (MVL and LED). Mycobacterial culture results provided the reference standard. A manually rechargeable battery-powered LED power source was evaluated in a random subset. RESULTS We evaluated 182 FNAB smears from 121 children (median age 31 months, interquartile range 10–67). Mycobacterial cultures were positive in 84 of 121 (69%) children. The mean sensitivity with LED (mains-powered), LED (rechargeable battery-powered) and MVL was respectively 48.2%, 50.0% and 51.8% (specificity 78.4%, 86.7% and 78.4%). Inter-observer variation was similar for LED and MVL (κ = 0.5). CONCLUSION LED fluorescence microscopy provides a reliable alternative to conventional methods and has many favourable attributes that would facilitate improved, decentralised diagnostic services. PMID:21276297

  6. Greater physician involvement improves coding outcomes in endobronchial ultrasound-guided transbronchial needle aspiration procedures.

    PubMed

    Pillai, Anilkumar; Medford, Andrew R L

    2013-01-01

    Correct coding is essential for accurate reimbursement for clinical activity. Published data confirm that significant aberrations in coding occur, leading to considerable financial inaccuracies especially in interventional procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Previous data reported a 15% coding error for EBUS-TBNA in a U.K. service. We hypothesised that greater physician involvement with coders would reduce EBUS-TBNA coding errors and financial disparity. The study was done as a prospective cohort study in the tertiary EBUS-TBNA service in Bristol. 165 consecutive patients between October 2009 and March 2012 underwent EBUS-TBNA for evaluation of unexplained mediastinal adenopathy on computed tomography. The chief coder was prospectively electronically informed of all procedures and cross-checked on a prospective database and by Trust Informatics. Cost and coding analysis was performed using the 2010-2011 tariffs. All 165 procedures (100%) were coded correctly as verified by Trust Informatics. This compares favourably with the 14.4% coding inaccuracy rate for EBUS-TBNA in a previous U.K. prospective cohort study [odds ratio 201.1 (1.1-357.5), p = 0.006]. Projected income loss was GBP 40,000 per year in the previous study, compared to a GBP 492,195 income here with no coding-attributable loss in revenue. Greater physician engagement with coders prevents coding errors and financial losses which can be significant especially in interventional specialties. The intervention can be as cheap, quick and simple as a prospective email to the coding team with cross-checks by Trust Informatics and against a procedural database. We suggest that all specialties should engage more with their coders using such a simple intervention to prevent revenue losses. Copyright © 2013 S. Karger AG, Basel.

  7. Fine-needle aspiration in the diagnosis of equine skin disease and the epidemiology of equine skin cytology submissions in a western Canadian diagnostic laboratory.

    PubMed

    Zachar, Erin K; Burgess, Hilary J; Wobeser, Bruce K

    2016-06-01

    Fine-needle aspiration (FNA) is commonly used to diagnose skin disease in companion animals, but its use in horses appears to be infrequent. Equine veterinarians in western Canada were surveyed to determine their opinions about FNA and 15 years of diagnostic submissions were used to compare the perceived to actual value of FNA in the diagnosis of skin disease in horses. Practitioners viewed FNA as quick, easy, economical, and minimally invasive. However, most veterinarians rarely chose to use FNA due to a perception that sample quality and diagnostic yield were poor and there was a narrow range of diseases the technique could diagnose. Analysis of the FNA cytology samples from a veterinary diagnostic laboratory showed a wide variety of equine skin disease conditions, but the frequency of non-diagnostic results was significantly higher in equine submissions compared to those from dogs and cats.

  8. Diagnostic value of liquid‐based cytology with fine needle aspiration specimens for cervical lymphadenopathy

    PubMed Central

    Goto, Takashi; Akahane, Toshiaki; Ohnuki, Natsumi; Yamaguchi, Tomomi; Kamada, Hajime; Harabuchi, Yasuaki; Tanaka, Shinya; Nishihara, Hiroshi

    2016-01-01

    Background Cervical lymphadenopathy is a symptom that is frequently seen among outpatients, and it is important to differentiate malignant lesions from reactive lymphoid hyperplasia. Fine needle aspiration (FNA) cytology has been widely used for the diagnosis of cervical lymphadenopathy. However, some limitations of the diagnostic accuracy using conventional smear (CS) cytology have been pointed out. The diagnostic value of liquid‐based cytology (LBC) with FNA specimens has not yet been fully proven. Methods Forty‐two patients with cervical lymphadenopathy who underwent FNA with CS cytology from 2007 to 2011 and 123 patients who underwent FNA with LBC utilizing LBCPREP2™ from 2011 to 2015 were studied. Diagnostic values were compared between the CS and the LBC groups. Results Of the total 165 patients representing the combined CS and LBC groups, 81 (49.1%) were diagnosed as benign lymph node and 84 (50.9%) were malignant diseases including 37 (22.4%) of metastatic carcinoma except for thyroid carcinoma, 30 (18.2%) of metastatic thyroid carcinoma, and 17 (10.3%) of malignant lymphoma. The overall statistical values including sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the CS were 75%, 100%, 100%, 78.9%, and 87.1%, respectively, whereas those values for LBC were 91.2%, 100%, 100%, 90.7%, and 95.3%, respectively. The sensitivity of LBC for malignant diseases tended to be higher than that of CS cytology (p = 0.081). Conclusion LBC with FNA specimens from cervical lymphadenopathy is a useful and reliable method for the diagnosis of malignant diseases, especially of metastatic carcinomas, due to its increased sensitivity compared with CS cytology. Diagn. Cytopathol. 2016;44:169–176. © 2016 Wiley Periodicals, Inc. PMID:26748563

  9. Lung malignancy: Diagnostic accuracies of bronchoalveolar lavage, bronchial brushing, and fine needle aspiration cytology

    PubMed Central

    Sareen, Rateesh; Pandey, C L

    2016-01-01

    Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992

  10. ADM3, TFF3 and LGALS3 are discriminative molecular markers in fine-needle aspiration biopsies of benign and malignant thyroid tumours

    PubMed Central

    Karger, S; Krause, K; Gutknecht, M; Schierle, K; Graf, D; Steinert, F; Dralle, H; Führer, D

    2012-01-01

    Background: Previously, we reported a six-marker gene set, which allowed a molecular discrimination of benign and malignant thyroid tumours. Now, we evaluated these markers in fine-needle aspiration biopsies (FNAB) in a prospective, independent series of thyroid tumours with proven histological outcome. Methods: Quantitative RT–PCR was performed (ADM3, HGD1, LGALS3, PLAB, TFF3, TG) in the needle wash-out of 156 FNAB of follicular adenoma (FA), adenomatous nodules, follicular and papillary thyroid cancers (TC) and normal thyroid tissues (NT). Results: Significant expression differences were found for TFF3, HGD1, ADM3 and LGALS3 in FNAB of TC compared with benign thyroid nodules and NT. Using two-marker gene sets, a specific FNAB distinction of benign and malignant tumours was achieved with negative predictive values (NPV) up to 0.78 and positive predictive values (PPV) up to 0.84. Two FNAB marker gene combinations (ADM3/TFF3; ADM3/ACTB) allowed the distinction of FA and malignant follicular neoplasia with NPV up to 0.94 and PPV up to 0.86. Conclusion: We demonstrate that molecular FNAB diagnosis of benign and malignant thyroid tumours including follicular neoplasia is possible with recently identified marker gene combinations. We propose multi-centre FNAB studies on these markers to bring this promising diagnostic tool closer to clinical practice. PMID:22223087

  11. Chest tube drainage versus needle aspiration for primary spontaneous pneumothorax: which is better?

    PubMed Central

    Wang, Chengdi; Lyu, Mengyuan; Zhou, Jian; Liu, Yang

    2017-01-01

    Background Needle aspiration and chest tube drainages are two main treatments for primary spontaneous pneumothorax (PSP). However, the application of needle aspiration or chest tube drainages has not reached a consensus. The aim of this study is to compare the needle aspiration with chest tube drainages in patients suffering with PSP and therefore help offer suggestions for clinical practice. Methods We searched literatures from PubMed, OVID and Web of Science from their inception to June 30, 2017. Continuous and dichotomous outcomes were expressed by weight mean difference (WMD) and risk ratio (RR) respectively, and each with 95% confidence intervals (CIs). We used the fixed effect or random effect model to perform quantitative synthesis. Results A total of 6 RCTs recruiting 458 participants were included in our analysis. On the basis of the six studies, our results indicated that compared with chest tube drainage applying needle aspiration shortened the hospital stay (WMD: ‒1.67 days; 95% CI: ‒2.25 to 1.08; P<0.001) and decreased hospitalization rate (RR: 0.40; 95% CI: 0.22–0.75; P=0.004). However, there was no difference regarding immediate success rate (RR: 1.01; 95% CI: 0.70–1.46; P=0.96) and one-year recurrence rate (RR: 0.89; 95% CI: 0.58–1.38; P=0.61). Conclusions In the light of this present research, it is necessary to apply needle aspiration into treating PSP to reduce hospitalization rate and shorten hospital stay. However, the two treatments have no significant difference with respect to immediate success rate, one-year recurrence rate, one-week success rate, three-month recurrence rate or complication rate. PMID:29268413

  12. GeneXpert MTB/RIF Assay for the Diagnosis of Tuberculous Lymphadenitis on Concentrated Fine Needle Aspirates in High Tuberculosis Burden Settings.

    PubMed

    Tadesse, Mulualem; Abebe, Gemeda; Abdissa, Ketema; Aragaw, Dossegnaw; Abdella, Kedir; Bekele, Alemayehu; Bezabih, Mesele; Apers, Ludwig; de Jong, Bouke C; Rigouts, Leen

    2015-01-01

    The diagnosis of tuberculous lymphadenitis (TBL) remains challenging. The routinely used methods (cytology and smear microscopy) have sub-optimal sensitivity. Recently, WHO recommends GeneXpert to be used as the initial diagnostic test in patients suspected of having extra-pulmonary tuberculosis (EPTB). However, this was a conditional recommendation due to very low-quality evidence available and more studies are needed. In this study we evaluated the performance of Xpert for the diagnosis of TBL on concentrated fine needle aspirates (FNA) in Southwest Ethiopia. FNA was collected from presumptive TBL cases. Two smears were prepared from each aspirate and processed for cytology and conventional microscopy. The remaining aspirate was treated with N-acetyl-L-cysteine-NaOH and centrifuged for 15minutes at 3000g. The concentrated sediment was used for culture and Xpert test. Capilia TB-Neo test was used to differentiate M. tuberculosis complex (MTBC) from non-tuberculous mycobacteria (NTM). Composite bacteriological methods (culture and/or smear microscopy) were considered as a reference standard. Out of 143 enrolled suspects, 64.3% (92/143) were confirmed TBL cases by the composite reference standard (CRS). Xpert detected M. tuberculosis complex (MTBC) in 60.1% (86/143) of the presumptive TBL cases. The sensitivity of Xpert compared to CRS was 87.8% [95% CI: 81.0-94.5] and specificity 91.1% [95% CI: 82.8-99.4]. The sensitivity was 27.8% for smear microscopy and 80% for cytology compared to CRS. Cytology showed the lowest specificity (57.8%). Xpert was positive in 4 out of 45 culture- and smear-negative cases. Among 47 cytomorphologically non-TBL cases, 15 were positive on Xpert. More than half of Xpert-positive cases were in the range of very low cut-off threshold values (28

  13. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    PubMed

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  14. Should fine needle aspiration biopsy be the first pathological investigation in the diagnosis of a bone lesion? An algorithmic approach with review of literature

    PubMed Central

    Mehrotra, Ravi; Singh, Mamta; Singh, Premala A; Mannan, Rahul; Ojha, Vinod K; Singh, Pradumyn

    2007-01-01

    Background Fine needle aspiration biopsy (FNAB) is gaining increasing popularity in the diagnosis of musculoskeletal lesions; and in many patients, a definitive diagnosis can be rendered from aspiration smears alone. Its applicability in bone pathology, however, has been controversial due to a high percentage of inadequate smears, difficulty in evaluation of tissue architecture and nonspecific results in the diagnosis of primary bone lesions. In this study, the value of aspiration as the first pathological investigation in the diagnosis of a bone lesion was evaluated. Methods 91 cases of clinically suspected cases of bone lesions were aspirated over a period of two years. Direct or cytospin smears were fixed in 95% alcohol and stained by Hematoxylin and Eosin or air-dried and later fixed in methanol for May Grŭnwald Giemsa staining. Results Of the 91 patients who were subjected to FNAB, 81 were considered satisfactory and 10.9 % (10) were inadequate\\inconclusive for diagnosis. Cyto-histological concordance was obtained in 78.5 % (51/65) patients. Positive and negative predictive values were 87.5% and 97.2 % respectively. Sensitivity as a preliminary diagnostic technique was 93.3%, whereas specificity was 94.5 %. Overall, diagnostic accuracy was 94.2 %. Metastatic lesions were detected with 100% accuracy. Two cases were reported as false positive and one case as false negative. Conclusion Cytology provides valuable information to the clinician to make an informed decision regarding appropriate therapy. We conclude that time-consuming and costly investigations may be reduced by choosing FNAB as the initial pathological diagnostic method for skeletal lesions of unknown origin. The choice of radiological examinations, laboratory tests and surgical biopsies can be determined after the FNAB diagnosis. PMID:17439659

  15. Endoscopic ultrasound elastography: Current status and future perspectives

    PubMed Central

    Cui, Xin-Wu; Chang, Jian-Min; Kan, Quan-Cheng; Chiorean, Liliana; Ignee, Andre; Dietrich, Christoph F

    2015-01-01

    Elastography is a new ultrasound modality that provides images and measurements related to tissue stiffness. Endoscopic ultrasound (EUS) has played an important role in the diagnosis and management of numerous abdominal and mediastinal diseases. Elastography by means of EUS examination can assess the elasticity of tumors in the proximity of the digestive tract that are hard to reach with conventional transcutaneous ultrasound probes, such as pancreatic masses and mediastinal or abdominal lymph nodes, thus improving the diagnostic yield of the procedure. Results from previous studies have promised benefits for EUS elastography in the differential diagnosis of lymph nodes, as well as for assessing masses with pancreatic or gastrointestinal (GI) tract locations. It is important to mention that EUS elastography is not considered a modality that can replace biopsy. However, it may be a useful adjunct, improving the accuracy of EUS-fine needle aspiration biopsy (EUS-FNAB) by selecting the most suspicious area to be targeted. Even more, it may be useful for guiding further clinical management when EUS-FNAB is negative or inconclusive. In the present paper we will discuss the current knowledge of EUS elastography, including the technical aspects, along with its applications in the differential diagnosis between benign and malignant solid pancreatic masses and lymph nodes, as well as its aid in the differentiation between normal pancreatic tissues and chronic pancreatitis. Moreover, the emergent indication and future perspectives are summarized, such as the benefit of EUS elastography in EUS-guided fine needle aspiration biopsy, and its uses for characterization of lesions in liver, biliary tract, adrenal glands and GI tract. PMID:26715804

  16. Needle tip visualization by bevel-point ultrasound generator and prototype photoacoustic imaging system

    NASA Astrophysics Data System (ADS)

    Irisawa, Kaku; Murakoshi, Dai; Hashimoto, Atsushi; Yamamoto, Katsuya; Hayakawa, Toshiro

    2017-03-01

    Visualization of the tip of medical devices like needles or catheters under ultrasound imaging has been a continuous topic since the early 1980's. In this study, a needle tip visualization system utilizing photoacoustic effects is proposed. In order to visualize the needle tip, an optical fiber was inserted into a needle. The optical fiber tip is placed on the needle bevel and affixed with black glue. The pulsed laser light from laser diode was transferred to the optical fiber and converted to ultrasound due to laser light absorption of the black glue and the subsequent photoacoustic effect. The ultrasound is detected by transducer array and reconstructed into photoacoustic images in the ultrasound unit. The photoacoustic image is displayed with a superposed ultrasound B-mode image. As a system evaluation, the needle is punctured into bovine meat and the needle tip is observed with commercialized conventional linear transducers or convex transducers. The needle tip is visualized clearly at 7 and 12 cm depths with linear and convex probes, respectively, even with a steep needle puncture angle of around 90 degrees. Laser and acoustic outputs, and thermal rise at the needle tip, were measured and were well below the limits of the safety standards. Compared with existing needle tip visualization technologies, the photoacoustic needle tip visualization system has potential distinguishable features for clinical procedures related with needle puncture and injection.

  17. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    PubMed

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  18. Gene Methylation and Cytological Atypia in Random Fine Needle Aspirates for Assessment of Breast Cancer Risk

    PubMed Central

    Hafeez, Sidra; Bujanda, Zoila Lopez; Chatterton, Robert T.; Jacobs, Lisa K.; Khouri, Nagi F.; Ivancic, David; Kenney, Kara; Shehata, Christina; Jeter, Stacie C.; Wolfman, Judith A.; Zalles, Carola M.; Huang, Peng

    2016-01-01

    Methods to determine individualized breast cancer risk lack sufficient sensitivity to select women most likely to benefit from preventive strategies. Alterations in DNA methylation occur early in breast cancer. We hypothesized that cancer-specific methylation markers could enhance breast cancer risk assessment. We evaluated 380 women without a history of breast cancer. We determined their menopausal status or menstrual cycle phase, risk of developing breast cancer (Gail model), and breast density, and obtained random fine needle aspiration (rFNA) samples for assessment of cytopathology and cumulative methylation index (CMI). Eight methylated gene markers were identified through whole genome methylation analysis and included novel and previously established breast cancer detection genes. We performed correlative and multivariate linear regression analyses to evaluate DNA methylation of a gene panel as a function of clinical factors associated with breast cancer risk. CMI and individual gene methylation were independent of age, menopausal status or menstrual phase, lifetime Gail risk score, and breast density. CMI and individual gene methylation for the eight genes increased significantly (p<0.001) with increasing cytological atypia. The findings were verified with multivariate analyses correcting for age, log (Gail), log (percent density), rFNA cell number and BMI. Our results demonstrate a significant association between cytological atypia and high CMI, which does not vary with menstrual phase or menopause and is independent of Gail risk and mammographic density. Thus CMI is an excellent candidate breast cancer risk biomarker, warranting larger prospective studies to establish its utility for cancer risk assessment. PMID:27261491

  19. Cost-effectiveness analysis of repeat fine-needle aspiration for thyroid biopsies read as atypia of undetermined significance.

    PubMed

    Heller, Michael; Zanocco, Kyle; Zydowicz, Sara; Elaraj, Dina; Nayar, Ritu; Sturgeon, Cord

    2012-09-01

    The 2007 National Cancer Institute (NCI) conference on Thyroid Fine-Needle Aspiration (FNA) introduced the category atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS). Repeat FNA in 3 to 6 months was recommended for low-risk patients. Compliance with these recommendations has been suboptimal. We hypothesized that repeat FNA would be more effective than diagnostic lobectomy, with decreased costs and improved rates of cancer detection. Cost-effectiveness analysis was performed in which we compared diagnostic lobectomy with repeat FNA. A Markov model was developed. Outcomes and probabilities were identified from literature review. Third-party payer costs were estimated in 2010 US dollars. Outcomes were weighted by use of the quality-of-life utility factors, yielding quality-adjusted life years (QALYs). Monte Carlo simulation and sensitivity analysis were used to examine the uncertainty of probability, cost, and utility estimates. The diagnostic lobectomy strategy cost $8,057 and produced 23.99 QALYs. Repeat FNA cost $2,462 and produced 24.05 QALYs. Repeat FNA was dominant until the cost of FNA increased to $6,091. Dominance of the repeat FNA strategy was not sensitive to the cost of operation or the complication rate. The NCI recommendations for repeat FNA regarding follow-up of AUS/FLUS results are cost-effective. Improving compliance with these guidelines should lead to less overall costs, greater quality of life, and fewer unnecessary operations. Copyright © 2012 Mosby, Inc. All rights reserved.

  20. Increases in thyroid nodule fine-needle aspirations, operations, and diagnoses of thyroid cancer in the United States.

    PubMed

    Sosa, Julie Ann; Hanna, John W; Robinson, Karen A; Lanman, Richard B

    2013-12-01

    To provide population-based estimates of trends in thyroid nodule fine-needle aspirations (FNA) and operative volumes, we used multiple claims databases to quantify rates of these procedures and their association with the increasing incidence of thyroid cancer in the United States. Private and public insurance claims databases were used to estimate procedure volumes from 2006 to 2011. Rates of FNA and thyroid operations related to thyroid nodules were defined by CPT4 codes associated with International Classification of Diseases, Ninth Revision Clinical Modification codes for nontoxic uni- or multinodular goiter and thyroid neoplasms. Use of thyroid FNA more than doubled during the 5-year study period (16% annual growth). The number of thyroid operations performed for thyroid nodules increased by 31%. Total thyroidectomies increased by 12% per year, whereas lobectomies increased only 1% per year. In 2011, total thyroidectomies accounted for more than half (56%) of the operations for thyroid neoplasms in the United States. Thyroid operations became increasingly (62%) outpatient procedures. Thyroid FNA and operative procedures have increased rapidly in the United States, with an associated increase in the incidence of thyroid cancer. The more substantial increase in number of total versus partial thyroid resections suggests that patients undergoing thyroid operation are perceived to have a greater risk of cancer as determined by preoperative assessments, but this trend could also increase detection of incidental microcarcinomas. Copyright © 2013 Mosby, Inc. All rights reserved.

  1. The value of mutational profiling of the cytocentrifugation supernatant fluid from fine-needle aspiration of pancreatic solid mass lesions.

    PubMed

    Deftereos, Georgios; Finkelstein, Sydney D; Jackson, Sara A; Ellsworth, Eric M G; Krishnamurti, Uma; Liu, Yulin; Silverman, Jan F; Binkert, Candy R; Ujevich, Beth A; Mohanty, Alok

    2014-04-01

    Fine-needle aspiration (FNA) of pancreatic solid masses can be significantly impacted by sampling variation. Molecular analysis of tumor DNA can be an aid for more definitive diagnosis. The aim of this study was to evaluate how molecular analysis of the cell-free cytocentrifugation supernatant DNA can help reduce sampling variability and increase diagnostic yield. Twenty-three FNA smears from pancreatic solid masses were performed. Remaining aspirates were rinsed for preparation of cytocentrifuged slides or cell blocks. DNA was extracted from supernatant fluid and assessed for DNA quantity spectrophotometrically and for amplifiability by quantitative PCR (qPCR). Supernatants with adequate DNA were analyzed for mutations using PCR/capillary electrophoresis for a broad panel of markers (KRAS point mutation by sequencing, microsatellite fragment analysis for loss of heterozygosity (LOH) of 16 markers at 1p, 3p, 5q, 9p, 10q, 17p, 17q, 21q, and 22q). In selected cases, microdissection of stained cytology smears and/or cytocentrifugation cellular slides were analyzed and compared. In all, 5/23 samples cytologically confirmed as adenocarcinoma showed detectable mutations both in the microdissected slide-based cytology cells and in the cytocentrifugation supernatant. While most mutations detected were present in both microdissected slides and supernatant fluid specimens, the latter showed additional mutations supporting greater sensitivity for detecting relevant DNA damage. Clonality for individual marker mutations was higher in the supernatant fluid than in microdissected cells. Cytocentrifugation supernatant fluid contains levels of amplifiable DNA suitable for mutation detection and characterization. The finding of additional detectable mutations at higher clonality indicates that supernatant fluid may be enriched with tumor DNA. Molecular analysis of the supernatant fluid could serve as an adjunct method to reduce sampling variability and increase diagnostic yield

  2. Clinical usefulness of fine needle aspiration cytology in patients less than 20 years old: a 10-year experience at a single institution.

    PubMed

    Kim, Sunzoo; Jang, Eun Jeong; Jeong, Ji Yun; Park, Ji Young

    2013-01-01

    The purpose of this study was to identify the spectrum of cytological diagnoses and evaluate the diagnostic effectiveness of fine needle aspiration cytology (FNA) in patients less than 20 years old. The subjects were selected by retrospectively reviewing records from 1999 to 2009. Selected patients less than 20 years old underwent FNA. Cytological and histological slides of samples from the subjects were reviewed. Our study included a total of 909 subjects with a mean age of 14.6 years. The majority of the FNA samples were taken from lymph nodes (n = 448, 49.3%), with the remaining aspirates obtained from the thyroid gland (n = 247, 27.2%), soft tissues of head and neck masses (n = 106, 11.7%), salivary glands (n = 75, 8.3%), breasts (n = 18, 1.9%), skins (n = 9, 1.0%) and soft tissues of extremity (n = 6, 0.7%). The majority (87.6%, n = 796) of the FNA samples were categorized as 'benign', with the remaining designated as 'atypical lesion' (n = 18, 2.0%), 'malignant' (n = 24, 2.6%), or 'inadequate specimen' (n = 71, 7.8%). FNA accuracy was 92% for diagnosing cancer. Specificity and sensitivity were 99% and 63%, respectively. Our study first revealed that FNA has a high specificity for diagnosing cancer in various anatomical locations in young patients and can be confidently used as an effective tool for diagnosing malignancies in young individuals with a clinically suspicious lesion.

  3. Endobronchial ultrasound-guided transbronchial needle aspiration in the diagnosis of non-lymph node thoracic lesions

    PubMed Central

    Yang, Huizhen; Zhao, Heng; Garfield, David H.; Teng, Jiajun; Han, Baohui; Sun, Jiayuan

    2013-01-01

    AIMS: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has shown excellent diagnostic capabilities for mediastinal and hilar lymphadenopathy. However, its value in thoracic non-lymph node lesions is less clear. This study was designed to assess the value of EBUS-TBNA in distinguishing malignant from benign thoracic non-lymph node lesions. METHODS: From October 2009 to August 2011, 552 patients underwent EBUS-TBNA under local anesthesia and with conscious sedation. We retrospectively reviewed 81 of these patients who had tracheobronchial wall-adjacent intrapulmonary or isolated mediastinal non-lymph node lesions. On-site cytological evaluation was not used. Immunohistochemistry (IHC) was performed to distinguish the origin or type of malignancy when necessary. RESULTS: EBUS-TBNA was performed in 68 tracheobronchial wall-adjacent intrapulmonary and 13 isolated mediastinal non-lymph node lesions. Of the 81 patients, 77 (95.1%, 60 malignancies and 17 benignancies) were diagnosed through EBUS-TBNA, including 57 primary lung cancers, 2 mediastinal tumors, 1 pulmonary metastatic adenocarcinoma, 7 inflammation, 5 tuberculosis, 3 mediastinal cysts, 1 esophageal schwannoma, and 1 focal fibrosis. There were four false-negative cases (4.9%). Of the 60 malignancies, there were 9 (15.0%) which originally had no definite histologic origin or type. Thus, IHC was performed, with 7 (77.8%) being subsequently confirmed. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBUS-TBNA in distinguishing malignant from benign lesions were 93.4% (60/64), 100% (17/17), 100% (60/60), 81.0% (17/21), and 95.1% (77/81), respectively. CONCLUSION: EBUS-TBNA is a safe procedure with a high sensitivity for distinguishing malignant from benign thoracic non-lymph node lesions within the reach of EBUS-TBNA, with IHC usually providing a more definitive diagnosis. PMID:23439919

  4. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report.

    PubMed

    Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J

    2016-03-01

    Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights

  5. Accuracy of electromyography needle placement in cadavers: non-guided vs. ultrasound guided.

    PubMed

    Boon, Andrea J; Oney-Marlow, Theresa M; Murthy, Naveen S; Harper, Charles M; McNamara, Terrence R; Smith, Jay

    2011-07-01

    Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory. Copyright © 2011 Wiley Periodicals, Inc.

  6. Role of Core Needle Biopsy in the Management of Atypia/Follicular Lesion of Undetermined Significance Thyroid Nodules: Comparison with Repeat Fine-Needle Aspiration in Subcategory Nodules

    PubMed Central

    Na, Dong Gyu; Min, Hye Sook; Lee, Hunkyung; Won, Jae-Kyung; Seo, Hyo Bin; Kim, Ji-Hoon

    2015-01-01

    Background The role of repeat fine-needle aspiration (RFNA) or core needle biopsy (CNB) has not been established in nodules categorized as atypia/follicular lesion of undetermined significance (AUS/FLUS). Objective The purpose of this study was to retrospectively determine whether CNB is more useful for management decisions than RFNA at each subcategory of AUS/FLUS nodules. Methods This study included 158 AUS/FLUS nodules (≥1 cm) from 153 consecutive patients who underwent both RFNA and CNB. The AUS/FLUS nodules were subcategorized into nuclear atypia (NA) and follicular lesions with other atypia (FOA). The diagnostic results and rate of determined management by RFNA and CNB were compared at each subcategory. The diagnostic values of RFNA and CNB for malignancy were evaluated in nodules with final diagnoses. Results CNB showed a lower rate of AUS/FLUS diagnosis, higher rates of benign and follicular neoplasm or suspicious for a follicular neoplasm (FN/SFN) diagnoses (p ≤ 0.038), and marginally higher rates of malignant diagnosis than RFNA in the NA subcategory. CNB showed a higher rate of FN/SFN (p = 0.007) than RFNA in the FOA subcategory. CNB also demonstrated a higher rate of surgery decision than RFNA in both the NA subcategory (20.2 vs. 9.6%, p < 0.001) and FOA subcategory (20.8 vs. 5.6%, p = 0.007), and a higher rate of observation decision only in the NA subcategory (48.1 vs. 35.6%, p = 0.035). CNB demonstrated a higher diagnostic performance for malignancy overall in the nodules compared with RFNA. Conclusion CNB may be more useful for management decisions than RFNA in both the NA and FOA subcategories, and has the potential to be a first-line alternative diagnostic tool in initially diagnosed AUS/FLUS nodules. PMID:26558236

  7. Endobronchial Ultrasound-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration.

    PubMed

    Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T

    2016-05-01

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA

  8. Gene Methylation and Cytological Atypia in Random Fine-Needle Aspirates for Assessment of Breast Cancer Risk.

    PubMed

    Stearns, Vered; Fackler, Mary Jo; Hafeez, Sidra; Bujanda, Zoila Lopez; Chatterton, Robert T; Jacobs, Lisa K; Khouri, Nagi F; Ivancic, David; Kenney, Kara; Shehata, Christina; Jeter, Stacie C; Wolfman, Judith A; Zalles, Carola M; Huang, Peng; Khan, Seema A; Sukumar, Saraswati

    2016-08-01

    Methods to determine individualized breast cancer risk lack sufficient sensitivity to select women most likely to benefit from preventive strategies. Alterations in DNA methylation occur early in breast cancer. We hypothesized that cancer-specific methylation markers could enhance breast cancer risk assessment. We evaluated 380 women without a history of breast cancer. We determined their menopausal status or menstrual cycle phase, risk of developing breast cancer (Gail model), and breast density and obtained random fine-needle aspiration (rFNA) samples for assessment of cytopathology and cumulative methylation index (CMI). Eight methylated gene markers were identified through whole-genome methylation analysis and included novel and previously established breast cancer detection genes. We performed correlative and multivariate linear regression analyses to evaluate DNA methylation of a gene panel as a function of clinical factors associated with breast cancer risk. CMI and individual gene methylation were independent of age, menopausal status or menstrual phase, lifetime Gail risk score, and breast density. CMI and individual gene methylation for the eight genes increased significantly (P < 0.001) with increasing cytological atypia. The findings were verified with multivariate analyses correcting for age, log (Gail), log (percent density), rFNA cell number, and body mass index. Our results demonstrate a significant association between cytological atypia and high CMI, which does not vary with menstrual phase or menopause and is independent of Gail risk and mammographic density. Thus, CMI is an excellent candidate breast cancer risk biomarker, warranting larger prospective studies to establish its utility for cancer risk assessment. Cancer Prev Res; 9(8); 673-82. ©2016 AACR. ©2016 American Association for Cancer Research.

  9. A new needle on the block: EchoTip ProCore endobronchial ultrasound needle

    PubMed Central

    Dincer, H Erhan; Andrade, Rafael; Zamora, Felix; Podgaetz, Eitan

    2016-01-01

    Endobronchial ultrasound has become the first choice standard of care procedure to diagnose benign or malignant lesions involving mediastinum and lung parenchyma adjacent to the airways owing to its characteristics of being real-time and minimally invasive. Although the incidence of lung cancer has been decreasing, it is and will be the leading cause of cancer-related mortality in the next few decades. When compared to other cancers, lung cancer kills more females than breast and colon cancers combined and more males than colon and prostate cancers combined. The type of lung cancer has changed in recent decades and adenocarcinoma has become the most frequent cell type. Prognosis of lung cancer depends upon the cell type and the staging at the time of diagnosis. The cell type and molecular characteristics of adenocarcinoma may allow individualized targeted treatment. Other malignant conditions in the mediastinum and lung (eg, metastatic lung cancers and lymphoma) can be biopsied using endobronchial ultrasound needles. Endobronchial ultrasound needle biopsies provides mostly cytology specimens due to its small sizes of needles (22 gauge or larger) which may not give enough tissue to make a definitive diagnosis in malignant (eg, lymphoma) or benign conditions (eg, sarcoidosis). EchoTip ProCore endobronchial needle released in early 2014 provides histologic biopsy material. Larger tissue biopsies may potentially provide a higher diagnostic yield and it eliminates mediastinoscopy or other surgical interventions. Here we aim to review bronchoscopic approach in the diagnosis of mediastinal lesions with emphasis of EchoTip ProCore needles. PMID:27099535

  10. Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers.

    PubMed

    Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György

    2009-08-01

    Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers

  11. Electromyographic comparison of forearm muscle movements for fine skin suturing between an enlarged pen needle holder and a webster needle holder.

    PubMed

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting.

  12. Multi-resolution Gabor wavelet feature extraction for needle detection in 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Pourtaherian, Arash; Zinger, Svitlana; Mihajlovic, Nenad; de With, Peter H. N.; Huang, Jinfeng; Ng, Gary C.; Korsten, Hendrikus H. M.

    2015-12-01

    Ultrasound imaging is employed for needle guidance in various minimally invasive procedures such as biopsy guidance, regional anesthesia and brachytherapy. Unfortunately, a needle guidance using 2D ultrasound is very challenging, due to a poor needle visibility and a limited field of view. Nowadays, 3D ultrasound systems are available and more widely used. Consequently, with an appropriate 3D image-based needle detection technique, needle guidance and interventions may significantly be improved and simplified. In this paper, we present a multi-resolution Gabor transformation for an automated and reliable extraction of the needle-like structures in a 3D ultrasound volume. We study and identify the best combination of the Gabor wavelet frequencies. High precision in detecting the needle voxels leads to a robust and accurate localization of the needle for the intervention support. Evaluation in several ex-vivo cases shows that the multi-resolution analysis significantly improves the precision of the needle voxel detection from 0.23 to 0.32 at a high recall rate of 0.75 (gain 40%), where a better robustness and confidence were confirmed in the practical experiments.

  13. Aspiration cytology of extramammary tumours metastatic to the breast.

    PubMed

    Handa, Uma; Chhabra, Seema; Mohan, Harsh

    2007-10-01

    This study was undertaken to highlight the use of fine needle aspiration cytology (FNAC) to distinguish tumours metastatic to the breast from primary breast malignancies. A total of 1866 fine needle aspirates of the breast were performed during a period of 7 years. Three hundred and fourteen cases of breast malignancies were diagnosed and 5 (1.5%) out of these cases were metastatic in origin. The metastatic tumors included, 2 cases of malignant melanoma (chest wall and left arm), 1 case each of haematolymphoid malignancy, adenocarcinoma of the ovary, and squamous cell carcinoma (left leg). FNA diagnosis of metastasis to the breast is essential in order to avoid unnecessary mastectomy and to ensure appropriate chemotherapy and/or irradiation treatment.

  14. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology.

    PubMed

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  15. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology

    PubMed Central

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation. PMID:28100998

  16. Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.

    PubMed

    Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N

    2015-01-01

    The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.

  17. Assessment of Fine Needle Aspiration Feasibility and Specimen Adequacy for Molecular Diagnostics of Benign Vocal Fold Lesions

    PubMed Central

    Li, Nicole Y. K.; Dailey, Seth; Thibeault, Susan L.

    2014-01-01

    Objectives/Hypothesis The use of molecular testing is becoming more significant for the diagnosis and classification of disease. The application of fine-needle aspiration (FNA) biopsy as the means of sampling lesions in union with molecular testing could be a powerful combination in laryngology. The objectives of this study were to investigate 1) if FNA was feasible to sample benign vocal fold lesions; 2) if FNA samples provided sufficient RNA quality for molecular analysis; and 3) if gene expression of FNA samples matched paired surgical excised specimens. Study Design Prospective cross-sectional. Methods Fifteen vocal fold specimens were obtained from adult patients undergoing routine surgical removal for benign vocal fold lesions using FNA and surgical excision. Comparisons were made between FNA and excision biopsies for RNA quality. Correlative analysis was completed for RNA expression of nine genes, including decorin (DCN), connective tissue growth factor (CTGF), vascular endothelial growth factor (VEGF), collagen type VI alpha 3 (COL6A3), superoxide dismutase 1 (SOD1), glutathione S-transferase (GST2), collagen type I alpha 2 (COL1A2), ATP binding cassette (ABC), and procollagen I alpha 1 (COL1A1). Results FNA and excision samples demonstrated similar RNA quality (P > 0.05). Per gene expression, four out of nine genes were moderately correlated between the paired samples (P < 0.05). Conclusions FNA of the vocal fold lamina propria is technically feasible to perform. Further improvement in the FNA technology is desirable to optimize RNA quality for reliable gene expression analysis. PMID:23404571

  18. Electromyographic Comparison of Forearm Muscle Movements for Fine Skin Suturing Between an Enlarged Pen Needle Holder and a Webster Needle Holder

    PubMed Central

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    Background: For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. Methods: A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. Results: The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Conclusions: Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting. PMID:23691259

  19. Point of care assessment of melanoma tumor signaling and metastatic burden from μNMR analysis of tumor fine needle aspirates and peripheral blood.

    PubMed

    Gee, Michael S; Ghazani, Arezou A; Haq, Rizwan; Wargo, Jennifer A; Sebas, Matthew; Sullivan, Ryan J; Lee, Hakho; Weissleder, Ralph

    2017-04-01

    This study evaluates μNMR technology for molecular profiling of tumor fine needle aspirates and peripheral blood of melanoma patients. In vitro assessment of melanocyte (MART-1, HMB45) and MAP kinase signaling (pERK, pS6K) molecule expression was performed in human cell lines, while clinical validation was performed in an IRB-approved study of melanoma patients undergoing biopsy and blood sampling. Tumor FNA and blood specimens were compared with BRAF genetic analysis and cross-sectional imaging. μNMR in vitro analysis showed increased expression of melanocyte markers in melanoma cells as well as increased expression of phosphorylated MAP kinase targets in BRAF-mutant melanoma cells. Melanoma patient FNA samples showed increased pERK and pS6K levels in BRAF mutant compared with BRAF WT melanomas, with μNMR blood circulating tumor cell level increased with higher metastatic burden visible on imaging. These results indicate that μNMR technology provides minimally invasive point-of-care evaluation of tumor signaling and metastatic burden in melanoma patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Assay of free thyroxine and free triiodothyronine in fine-needle aspiration of thyroid nodules: a useful and low-cost assessment.

    PubMed

    Barbaro, Daniele; Macchia, Enrico; Orsini, Paola; Piazza, Francesca; Lapi, Paola; Pasquini, Cristina

    2004-01-01

    To evaluate whether analysis of thyroid hormones in fine-needle aspiration (FNA) of thyroid nodules can provide information about the functional status and the nature of the nodules. We studied 4 groups of patients: group 1, 17 patients with autonomous hyperfunctioning thyroid nodules; group 2, 52 patients with cold nonfunctioning thyroid nodules; group 3, 12 patients with malignant thyroid nodules; and group 4 (control group), 10 patients with nonthyroid nodular lesions (enlarged parathyroid glands or lymph nodes). The assay of thyroid hormones was performed in FNA after the washing of needles and, with patient consent, also in normal thyroid parenchyma. The free thyroxine (FT(4)) and free triiodothyronine (FT(3)) values were remarkably high in group 1 (mean, 5.5 +/- 0.53 ng/dL and 27.6 +/- 3.1 pg/mL, respectively; P<0.05 versus group 2 and group 4, the control group). The levels of FT(4) and FT(3) were very low in group 3 (<0.2 ng/dL and <1.0 pg/mL, respectively; P<0.05 versus group 2). Thyroglobulin values in FNA specimens were much higher than the normal range in human serum, but no significant differences were found between the various groups. The control group had low levels of FT(4) and FT(3) (<0.2 ng/dL and <1.0 pg/mL, respectively) in conjunction with low levels of thyroglobulin, whereas parathyroid hormone levels were high in parathyroid nodules. These results show that assay of FT(4) and FT(3) in FNA can yield information about the functional status of thyroid nodules and, indirectly, about the nature of nodules. In this era of sophisticated new molecular markers in FNA cytology, this low-cost diagnostic method can be readily performed in every laboratory.

  1. Endobronchial ultrasound-guided lymph node biopsy with transbronchial needle forceps: a pilot study.

    PubMed

    Herth, F J F; Schuler, H; Gompelmann, D; Kahn, N; Gasparini, S; Ernst, A; Schuhmann, M; Eberhardt, R

    2012-02-01

    One limitation of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the size of the available needles, frequently yielding only cells for cytological examination. The aim of this pilot study was to evaluate the efficacy and safety of newly developed needle forceps to obtain tissue for the histological diagnosis of enlarged mediastinal lymph nodes. Patients with enlarged, positron emission tomography (PET)-positive lymph nodes were included. The transbronchial needle forceps (TBNF), a sampling instrument combining the characteristics of a needle (bevelled tip for penetrating through the bronchial wall) with forceps (two serrated jaws for grasping tissue) was used through the working channel of the EBUS-TBNA scope. Efficacy and safety was assessed. 50 patients (36 males and 14 females; mean age 51 yrs) with enlarged or PET-positive lymph nodes were included in this pilot study. In 48 (96%) patients penetration of the bronchial wall was possible and in 45 patients tissue for histological diagnosis was obtained. In three patients TBNF provided inadequate material. For patients in whom the material was adequate for a histological examination, a specific diagnosis was established in 43 (86%) out of 50 patients (nonsmall cell lung cancer: n=24; small cell lung cancer: n=7; sarcoidosis: n=4; Hodgkin's lymphoma: n=4; tuberculosis: n=2; and non-Hodgkin's lymphoma: n=2).No clinically significant procedure-related complications were encountered. This study demonstrated that EBUS-TBNF is a safe procedure and provides diagnostic histological specimens of mediastinal lymph nodes.

  2. Atypia in random periareolar fine-needle aspiration affects the decision of women at high risk to take tamoxifen for breast cancer chemoprevention.

    PubMed

    Goldenberg, Vanessa K; Seewaldt, Victoria L; Scott, Victoria; Bean, Gregory R; Broadwater, Gloria; Fabian, Carol; Kimler, Bruce; Zalles, Carola; Lipkus, Isaac M

    2007-05-01

    Random periareolar fine-needle aspiration (RPFNA) is a research procedure designed to (a) evaluate short-term breast cancer risk in women at high risk for developing breast cancer, and (b) track response to chemoprevention. Of import, cellular atypia in breast RPFNA is prospectively associated with a 5.6-fold increase in breast cancer risk in women at high risk. Among 99 women attending a clinic for high-risk breast cancer, we explored the effects of RPFNA cytology results on decision making pertaining to the use of tamoxifen for breast cancer chemoprevention. No patient with nonproliferative or hyperplastic cytology subsequently elected to take tamoxifen. Only 7% of subjects with borderline atypia elected to take tamoxifen. In contrast, 50% with atypia elected to take tamoxifen. These results suggest that the provision of a biomarker of short-term risk can affect the motivation to take tamoxifen for chemoprevention. This conclusion is informative given that tamoxifen, due to its side effects, is often underused by women at high risk of developing breast cancer. Further research is needed to determine the mechanisms through which RPFNA results affect the decision to use tamoxifen, or any other breast cancer chemopreventive agent.

  3. Deep Needle Procedures: Improving Safety With Ultrasound Visualization

    PubMed Central

    Peabody, Christopher R.; Mandavia, Diku

    2017-01-01

    Abstract Promoting patient safety and increasing health care quality have dominated the health care landscape during the last 15 years. Health care regulators and payers are now tying patient safety outcomes and best practices to hospital reimbursement. Many health care leaders are searching for new technologies that not only make health care for patients safer but also reduce overall health care costs. New advances in ultrasonography have made this technology available to health care providers at the patient’s bedside. Point-of-care ultrasound assistance now aids providers with real-time diagnosis and with visualization for procedural guidance. This is especially true for common deep needle procedures such as central venous catheter insertion, thoracentesis, and paracentesis. There is now mounting evidence that clinician-performed point-of-care ultrasound improves patient safety, enhances health care quality, and reduces health care cost for deep needle procedures. Furthermore, the miniaturization, ease of use, and the evolving affordability of ultrasound have now made this technology widely available. The adoption of point-of-care ultrasonography has reached a tipping point and should be seriously considered the safety standard for all hospital-based deep needle procedures. PMID:24786918

  4. Endoscopic ultrasound in gastroenterology: from diagnosis to therapeutic implications.

    PubMed

    Mekky, Mohamed A; Abbas, Wael A

    2014-06-28

    Since its advent in 1980, the scope of endoscopic ultrasound (EUS) has grown to include a wide range of indications, and it is now being incorporated as an integral part of everyday practice in the field of gastroenterology. Its use is extending from an adjuvant imaging aid to utilization as a therapeutic tool for various gastrointestinal disorders. EUS was first used to visualize remote organs, such as the pancreas and abdominal lymph nodes. When fine needle aspiration was introduced, the indications for EUS expanded to include tissue sampling for diagnostic purposes. At the same time, the needle can be used to convey a potential therapy to the internal organs, allowing access to remote sites. In this review, we aim to highlight the expanding spectrum of EUS indications and uses in the field of gastroenterology.

  5. [Results of endobronchial ultrasound-guided transbronchial needle aspiration in lung cancer: importance of the lymph node involvement prevalence].

    PubMed

    De Dominicis, F; Fourdrain, A; Iquille, J; Toublanc, B; François, G; Basille, D; Monconduit, J; Merlusca, G; Jounieaux, V; Andrejak, C; Berna, P

    2015-08-01

    We studied the non-surgical invasive staging by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and we detailed the differences of our series, in order to understand the criteria allowing to achieve a better performance. Retrospective observational study conducted between 2007 and 2011, including all patients with proven NSCLC who underwent EBUS-TBNA. For the 92 EBUS-TBNA performed, we found a sensitivity of 78%, a specificity of 93%, a positive predictive value (PPV) of 98%, a negative predictive value (NPV) of 45%, an accuracy of 80% and a prevalence of lymph node involvement at 84%. A learning curve has been demonstrated and a significant difference was found based on the number of punctures by procedure (P=0.02) or on histological type (P=0.02). By analyzing the data of the literature, we have been able to demonstrate that the accuracy and the negative predictive value are correlated with the prevalence. If we take into account this correlation, we can consider the results of our study close to those of the literature. We highlighted a number of criteria that will influence the diagnostic yield of EBUS-TBNA. While some have already been described, other criteria such as histological type or patient selection criteria are less discussed. The key point is the correlation between the prevalence and EBUS-TBNA results. Results of the assessment of lymph node involvement techniques should be interpreted according to the prevalence of lymph node involvement. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Molecular Testing for Targeted Therapy in Advanced Non-Small Cell Lung Cancer: Suitability of Endobronchial Ultrasound Transbronchial Needle Aspiration.

    PubMed

    Casadio, Chiara; Guarize, Juliana; Donghi, Stefano; Di Tonno, Clementina; Fumagalli, Caterina; Vacirca, Davide; Dell'Orto, Patrizia; De Marinis, Filippo; Spaggiari, Lorenzo; Viale, Giuseppe; Barberis, Massimo

    2015-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure that has revolutionized the diagnosis and staging of lung cancer. The goal of the present study was to investigate the yield and applicability of molecular testing in the specimens obtained by EBUS-TBNA from patients with advanced non-small cell lung cancer (NSCLC), comparing the results with a series of patients who underwent diagnostic surgical procedures in the same institution. The study followed 306 consecutive patients with clinically diagnosed primary lung cancer who had the EBUS-TBNA procedure. EGFR and KRAS mutations were evaluated on cytologic specimens by Sanger sequencing and Cobas real-time polymerase chain reaction, whereas ALK rearrangement was tested by fluorescence in situ hybridization. The results were compared with those obtained from a series of 1,000 NSCLC surgical samples routinely analyzed. Molecular testing was possible in 96.9% of the samples obtained by EBUS-TBNA. EGFR (exons 18-21) mutations were found in 16.9%, KRAS mutation (exons 2-3) in 31.6%, and ALK rearrangement in 3.9% of the cases. In the surgical series, the mutations' distribution were 14.8%, 29.0%, and 3.4%, respectively. There were no statistical differences between the two series. Our study demonstrates that EBUS-TBNA can be effectively used not just for diagnosis but also for complete mutational testing. Copyright© by the American Society for Clinical Pathology.

  7. Thermal ablation of pancreatic cyst with a prototype endoscopic ultrasound capable radiofrequency needle device: A pilot feasibility study

    PubMed Central

    Moris, Maria; Atar, Mustafa; Kadayifci, Abdurrahman; Krishna, Murli; Librero, Ariston; Richie, Eugene; Brugge, William; Wallace, Michael B.

    2017-01-01

    Background and Objectives: Pancreatic cysts are evaluated by endoscopic ultrasound and fine needle aspiration (EUS). The only accepted treatment is pancreatectomy, which is associated with morbidity and mortality. This study evaluated the optimal thermal dosimetry of a novel radiofrequency ablation device using a standard electrosurgical unit in ex vivo cyst models. Methods: A modified EUS 22-gauge monopolar needle prototype with a tip electrode connected to a standard electrosurgical unit (Erbe USA, Marietta, GA, USA) was used to induce a subboiling point temperature. A cyst model was created using 2-cm sections of porcine small intestine ligated and filled with saline. After ablation, the cyst models were prepared for pathological evaluation. The epithelial layers were measured in at least two different sites with a micrometer and compared with the corresponding control sample. Results: Thirty-two cyst models were ablated with maximum temperatures of 50°C, 60°C, 90°C, and 97°C in 8, 11, 11, and 2 cysts, respectively. Longer ablation times were required to induce higher temperatures. A trend in the reduction in thickness of the measured layers was observed after exposure to higher temperatures. A temperature over 50°C was required for the ablation of the muscularis, submucosa, and villi, and over 60°C was required to ablate the mucosal crypts. Conclusions: In a preclinical model, a novel radiofrequency EUS-capable needle connected to a standard electrosurgical unit using standard low-voltage coagulation provided ablation in a temperature-dependent fashion with a threshold of at least 60°C and a safe cyst margin below 97°C. This potentially will allow low-cost, convenient cyst ablation. PMID:28440238

  8. Endoscopic ultrasound (EUS) guided fine needle biopsy (FNB) with the Procore™ needle provides inadequate material for the histological diagnosis of early chronic pancreatitis.

    PubMed

    Iglesias García, Julio; Lariño-Noia, José; Abdulkader Nallib, Ihab; Lindkvist, Björn; Domínguez-Muñoz, J Enrique

    2018-05-03

    diagnosis of early chronic pancreatitis (CP) is hampered due to the low accuracy of current imaging techniques and the absence of methods for histological confirmation. We aimed to evaluate the efficacy of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for the histological diagnosis of early CP. a prospective, cross-sectional, single-center study was designed. Consecutive patients referred for EUS with a clinical suspicion of CP were evaluated for inclusion into the study. Inclusion criteria were age > 18 years and indeterminate EUS findings for the diagnosis of CP according to the Rosemont classification. EUS-FNB of the body of the pancreas was performed with Procore™ needles. Tissue samples were immersed into a methanol-based buffered preservative solution for cytohistological evaluation. The quality of the samples obtained and the histological findings were evaluated. Procedure-related complications were recorded. the study was stopped after eleven patients were included due to safety concerns and poor diagnostic yield. The mean age of the patients was 50.3 years (range 33-70 years) and six were male. Samples were of poor quality in five cases, but were sufficient for cell-block evaluation. An inflammatory infiltration with mild fibrosis was identified in two cases and neither inflammatory infiltration nor fibrosis was identified in three cases. With regard to the other six cases, isolated inflammatory cells were observed in one case, although the cellularity was poor and unsuitable for cytological evaluation in five cases. There was one major complication (9.1%) of acute pancreatitis that required hospitalization for 48 hours. EUS-FNB is technically feasible in patients with EUS findings categorized as indeterminate for a CP diagnosis. However, the diagnostic yield is poor and there is a non-negligible risk of complications.

  9. Automatic Robotic Steering of Flexible Needles from 3D Ultrasound Images in Phantoms and Ex Vivo Biological Tissue.

    PubMed

    Mignon, Paul; Poignet, Philippe; Troccaz, Jocelyne

    2018-05-29

    Robotic control of needle bending aims at increasing the precision of percutaneous procedures. Ultrasound feedback is preferable for its clinical ease of use, cost and compactness but raises needle detection issues. In this paper, we propose a complete system dedicated to robotized guidance of a flexible needle under 3D ultrasound imaging. This system includes a medical robot dedicated to transperineal needle positioning and insertion, a rapid path planning for needle steering using bevel-tip needle natural curvature in tissue, and an ultrasound-based automatic needle detection algorithm. Since ultrasound-based automatic needle steering is often made difficult by the needle localization in biological tissue, we quantify the benefit of using flexible echogenic needles for robotized guidance under 3D ultrasound. The "echogenic" term refers to the etching of microstructures on the needle shaft. We prove that these structures improve needle visibility and detection robustness in ultrasound images. We finally present promising results when reaching targets using needle steering. The experiments were conducted with various needles in different media (synthetic phantoms and ex vivo biological tissue). For instance, with nitinol needles the mean accuracy is 1.2 mm (respectively 3.8 mm) in phantoms (resp. biological tissue).

  10. Comparative Assessment of Conventional Papanicolaou and Modified Ultrafast Papanicolaou Stains in Fine Needle Aspiration Samples and Body Fluids.

    PubMed

    Arul, P; Eniya, S; Pushparaj, Magesh; Masilamani, Suresh; Kanmani, P; Lingasamy, C

    2018-01-01

    Conventional Papanicolaou (Pap) stain has undergone many modifications; of these, ultrafast Pap stain is the most popular as it shortens the turnaround time of reporting. Application of modified ultrafast Pap (MUFP) stain in the evaluation of fine needle aspiration (FNA) samples and body fluids are scanty. To evaluate the utility of MUFP stain in various FNA samples and body fluids and compare the findings with those of conventional Pap stain. In this cross-sectional study, two wet-fixed and two airdried smears from each sample [301 samples (255 FNA samples and 46 body fluids)] were prepared and stained by the conventional Pap and MUFP stains, respectively. Concordant and discordant rate was calculated. Quality index (QI) of MUFP stain was assessed by background, overall staining, cell morphology, and nuclear characteristics. MUFP-stained smears were also categorized into excellent, good, and fair. The concordance rate for MUFP stain was 100%. QI of MUFP stain for breast, thyroid, lymph node, soft tissue, salivary gland, and body fluids was 0.9, 0.93, 0.95, 1, 0.94, and 1, respectively. Excellent quality of stain was noted in 53.2% and good in 24.6% of the cases allowing easy diagnosis. In 22.2% of fair cases, diagnosis was possible with some difficulties. Our study concluded that MUFP stain could be considered as a rapid and reliable diagnostic tool and can be applied on a regular basis in FNA samples and body fluids to offer immediate diagnosis. However, caution should be taken while reporting certain MUFP-stained smears to avoid over/under diagnosis.

  11. [Hepatic fine needle aspiration biopsy. Experience in the study of hepatic masses at the Salvador Zubiran National Institute of Nutrition].

    PubMed

    Angeles-Angeles, A; Gamboa-Domínguez, A; Velázquez Fernández, D; Muñoz-Fernández, L

    1994-01-01

    The results of 114 fine-needle aspiration biopsies (FNAB) of the liver performed during six years (1987-1992) at the Departament of Pathology of the Instituto Nacional de la Nutrición Salvador Zubirán are presented. All were done by radiologists under ultrasonographic (three cases) or computerized tomographic guidance (111 cases). In order to determine the diagnostic accuracy, diagnoses made by FNAB were compared with those made by histological examination (coarse biopsies or surgical specimens) and/or by other diagnostic procedures including the clinical follow-up. Six cases were excluded because clinical information was not available. In 92 cases (85.2%) a correct diagnosis was made, in six (5.5%) the sample was inadequate and in 10 (9.3%) the diagnosis made by FNAB was incorrect. The diagnoses made were as follows: hepatocarcinoma 44, metastatic carcinoma 27, inflammatory lesions 12, regeneration 10, normal eight, unclassified carcinoma five, and lymphoma two. The sensitivity was 96.2, specificity 93.1, positive predictive value 97.4, negative predictive value 90.0, accuracy 95.3 and prevalence 73.1. There were three false negative and two false positive for carcinoma. These figures are similar to those found by other authors. No relevant complications were observed. It is concluded that FNAB of the liver is a safe, inexpensive and reliable method in the diagnoses of liver masses.

  12. Real-time needle guidance with photoacoustic and laser-generated ultrasound probes

    NASA Astrophysics Data System (ADS)

    Colchester, Richard J.; Mosse, Charles A.; Nikitichev, Daniil I.; Zhang, Edward Z.; West, Simeon; Beard, Paul C.; Papakonstantinou, Ioannis; Desjardins, Adrien E.

    2015-03-01

    Detection of tissue structures such as nerves and blood vessels is of critical importance during many needle-based minimally invasive procedures. For instance, unintentional injections into arteries can lead to strokes or cardiotoxicity during interventional pain management procedures that involve injections in the vicinity of nerves. Reliable detection with current external imaging systems remains elusive. Optical generation and reception of ultrasound allow for depth-resolved sensing and they can be performed with optical fibers that are positioned within needles used in clinical practice. The needle probe developed in this study comprised separate optical fibers for generating and receiving ultrasound. Photoacoustic generation of ultrasound was performed on the distal end face of an optical fiber by coating it with an optically absorbing material. Ultrasound reception was performed using a high-finesse Fabry-Pérot cavity. The sensor data was displayed as an M-mode image with a real-time interface. Imaging was performed on a biological tissue phantom.

  13. Physician control of needle and syringe during aspiration-injection procedures with the new reciprocating syringe.

    PubMed

    Sibbitt, Wilmer; Sibbitt, Randy R; Michael, Adrian A; Fu, Druce I; Draeger, Hilda T; Twining, Jon M; Bankhurst, Arthur D

    2006-04-01

    To evaluate physician control of needle and syringe during aspiration-injection syringe procedures by comparing the new reciprocating procedure syringe to a traditional conventional syringe. Twenty-six physicians were tested for their individual ability to control the reciprocating and conventional syringes in typical aspiration-injection procedures using a novel quantitative needle-based displacement procedure model. Subsequently, the physicians performed 48 clinical aspiration-injection (arthrocentesis) procedures on 32 subjects randomized to the reciprocating or conventional syringes. Clinical outcomes included procedure time, patient pain, and operator satisfaction. Multivariate modeling methods were used to determine the experimental variables in the syringe control model most predictive of clinical outcome measures. In the model system, the reciprocating syringe significantly improved physician control of the syringe and needle, with a 66% reduction in unintended forward penetration (p < 0.001) and a 68% reduction in unintended retraction (p < 0.001). In clinical arthrocentesis, improvements were also noted: 30% reduction in procedure time (p < 0.03), 57% reduction in patient pain (p < 0.001), and a 79% increase in physician satisfaction (p < 0.001). The variables in the experimental system--unintended forward penetration, unintended retraction, and operator satisfaction--independently predicted the outcomes of procedure time, patient pain, and physician satisfaction in the clinical study (p < or = 0.001). The reciprocating syringe reduces procedure time and patient pain and improves operator satisfaction with the procedure syringe. The reciprocating syringe improves physician performance in both the validated quantitative needle-based displacement model and in real aspiration-injection syringe procedures, including arthrocentesis.

  14. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration versus Standard Bronchoscopic Modalities for Diagnosis of Sarcoidosis: A Meta-analysis

    PubMed Central

    Hu, Li-Xing; Chen, Ru-Xuan; Huang, Hui; Shao, Chi; Wang, Ping; Liu, Yong-Zhe; Xu, Zuo-Jun

    2016-01-01

    Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an effective technique used to precisely detect enlarged mediastinal lymph nodes. The efficacy of EBUS-TBNA versus standard modalities for the diagnosis of sarcoidosis remains to be elucidated. In this meta-analysis, we compared the efficacies of these methods. Methods: We searched PubMed, Embase, The Cochrane Library, Wanfang, Cpvip, CNKI, and the bibliographies of the relevant references. We analyzed the data obtained with Revman 5.2 (Nordic Cochrane Center, Copenhagen, Denmark) and Stata 12.0 software (Stata Corporation, College Station, TX, USA). The Mantel-Haenszel method was used to calculate the pooled odds ratio (OR) and 95% confidence intervals (CIs). Results: Sixteen studies with a total of 1823 participants met the inclusion criteria, and data were extracted regarding the diagnostic yield of each approach. The ORs for EBUS-TBNA versus transbronchial lung biopsy (TBLB) for the diagnosis of sarcoidosis ranged from 0.26 to 126.58, and the pooled OR was 5.89 (95% CI, 2.20–15.79, P = 0.0004). These findings indicated that EBUS-TBNA provided a much higher diagnostic yield than TBLB. The pooled OR for EBUS-TBNA + TBLB + endobronchial biopsy (EBB) versus TBNA + TBLB + EBB was 1.54 (95% CI, 0.61–3.93, P = 0.36), implying that there was no significant difference between their diagnostic yields. However, clinical heterogeneity was reflected in the nature of the studies and in the operative variables. Conclusions: The results of this meta-analysis suggest that EBUS-TBNA + TBLB + EBB could be used for the diagnosis of sarcoidosis, if available. At medical centers without EBUS-TBNA, TBNA + TBLB + EBB could be used instead. PMID:27364799

  15. Suboptimal Agreement Among Cytopathologists in Diagnosis of Malignancy Based on Endoscopic Ultrasound Needle Aspirates of Solid Pancreatic Lesions: A Validation Study.

    PubMed

    Marshall, Carrie; Mounzer, Rawad; Hall, Matt; Simon, Violette; Centeno, Barbara; Dennis, Katie; Dhillon, Jasreman; Fan, Fang; Khazai, Laila; Klapman, Jason; Komanduri, Srinadh; Lin, Xiaoqi; Lu, David; Mehrotra, Sanjana; Muthusamy, V Raman; Nayar, Ritu; Paintal, Ajit; Rao, Jianyu; Sams, Sharon; Shah, Janak; Watson, Rabindra; Rastogi, Amit; Wani, Sachin

    2018-07-01

    Despite the widespread use of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) to sample pancreatic lesions and the standardization of pancreaticobiliary cytopathologic nomenclature, there are few data on inter-observer agreement among cytopathologists evaluating pancreatic cytologic specimens obtained by EUS-FNA. We developed a scoring system to assess agreement among cytopathologists in overall diagnosis and quantitative and qualitative parameters, and evaluated factors associated with agreement. We performed a prospective study to validate results from our pilot study that demonstrated moderate to substantial inter-observer agreement among cytopathologists for the final cytologic diagnosis. In the first phase, 3 cytopathologists refined criteria for assessment of quantity and quality measures. During phase 2, EUS-FNA specimens of solid pancreatic lesions from 46 patients were evaluated by 11 cytopathologists at 5 tertiary care centers using a standardized scoring tool. Individual quantitative and qualitative measures were scored and an overall cytologic diagnosis was determined. Clinical and EUS parameters were assessed as predictors of unanimous agreement. Inter-observer agreement (IOA) was calculated using multi-rater kappa (κ) statistics and a logistic regression model was created to identify factors associated with unanimous agreement. The IOA for final diagnoses, based on cytologic analysis, was moderate (κ = 0.56; 95% CI, 0.43-0.70). Kappa values did not increase when categories of suspicious for malignancy, malignant, and neoplasm were combined. IOA was slight to moderate for individual quantitative (κ = 0.007; 95% CI, -0.03 to -0.04) and qualitative parameters (κ = 0.5; 95% CI, 0.47-0.53). Jaundice was the only factor associated with agreement among all cytopathologists on multivariate analysis (odds ratio for unanimous agreement, 5.3; 95% CI, 1.1-26.89). There is a suboptimal level of agreement among cytopathologists in the diagnosis

  16. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    NASA Astrophysics Data System (ADS)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  17. Use of FTA cards for the storage of breast carcinoma nucleic acid on fine-needle aspiration samples.

    PubMed

    Peluso, Anna Lucia; Cascone, Anna Maria; Lucchese, Lucrezia; Cozzolino, Immacolata; Ieni, Antonio; Mignogna, Chiara; Pepe, Stefano; Zeppa, Pio

    2015-10-01

    The preservation and storage of nucleic acids is important for DNA molecular techniques. The material obtained by fine-needle aspiration (FNA) is often scanty and can not be wasted. FTA cards are filter papers that immobilize and stabilize nucleic acids and can be stored at room temperature. The current study evaluated whether nucleic acids of breast carcinoma cells, obtained by FNA in a clinical setting, may be collected, stored, and preserved on FTA cards. Thirty breast carcinoma, 5 non-Hodgkin lymphoma (NHL), and 5 benign reactive lymph node (RLN) cell samples obtained by FNA were stored at -80 °C and on FTA cards. DNA extraction and polymerase chain reaction were performed on cells at -80 °C and on 2 punched disks of FTA cards. Fifty nanograms of extracted DNA from both sample types were used to amplify the Janus Kinase 2 (JAK2) gene. The mean value of DNA extracted from breast carcinoma cells was 28.19 ng/µL for that stored at -80 °C and 3.28 ng/µL for that stored on FTA cards. Agarose gel analysis demonstrated expected bands of DNA in 29 cases (97%) with both methods. The mean value of DNA extracted from NHL and RLN samples was 37.54 ng/µL and 4.28 ng/µL, respectively, and agarose gel analysis demonstrated bands of high molecular weight DNA in both methods. Significant differences in DNA yield were found between storage at -80 °C and FTA cards (P<.0001), but no differences were detected between 260/280 nm ratios in breast carcinoma and NHL/RLN samples. FTA cards can be conveniently used for the storage of breast carcinoma cells obtained by FNA, thus providing a reliable alternative to traditional methods. © 2015 American Cancer Society.

  18. Rapid on-site evaluation of fine needle aspiration specimens by cytology scientists: a review of 3032 specimens.

    PubMed

    Shield, P W; Cosier, J; Ellerby, G; Gartrell, M; Papadimos, D

    2014-10-01

    To determine: (1) the accuracy of cytology scientists at assessing specimen adequacy by rapid on-site evaluation (ROSE) at fine needle aspiration (FNA) cytology collections; and (2) whether thyroid FNA with ROSE has lower inadequacy rates than non-attended FNAs. The ROSE of adequacy for 3032 specimens from 17 anatomical sites collected over a 20-month period was compared with the final report assessment of adequacy. ROSE was performed by 19 cytology scientists. The report profile for 1545 thyroid nodules with ROSE was compared with that for 1536 consecutive non-ROSE thyroid FNAs reported by the same cytopathologists during the study period. ROSE was adequate in 75% (2276/3032), inadequate in 12% (366/3032) and in 13% (390/3032) no opinion was rendered. Of the 2276 cases assessed as adequate by ROSE, 2268 (99.6%) were finally reported as adequate for assessment; eight specimens had adequacy downgraded on the final report. Fifty eight per cent of cases with a ROSE assessment of inadequate were reported as adequate (212/366), whereas 93% (363/390) with no opinion rendered were reported as adequate. The overall final report adequacy rate for the 3032 specimens was 94% (2843/3032). Confirmation of a ROSE of adequacy at reporting was uniformly high amongst the 19 scientists, ranging from 98% to 100%. The inadequacy rate for thyroid FNAs with ROSE (6%) was significantly (P < 0.0001) lower than for non-ROSE thyroid FNAs (17%). A significantly (P = 0.02) higher proportion of adequate ROSE thyroid specimens was reported with abnormalities, compared with non-ROSE thyroid collections. Cytology scientists are highly accurate at determining specimen adequacy at ROSE for a wide range of body sites. ROSE of thyroid FNAs can significantly reduce inadequate reports. © 2014 John Wiley & Sons Ltd.

  19. False-negative BRAF V600E mutation results on fine-needle aspiration cytology of papillary thyroid carcinoma.

    PubMed

    Paek, Se Hyun; Kim, Byung Seup; Kang, Kyung Ho; Kim, Hee Sung

    2017-11-13

    The BRAF V600E mutation is highly specific for papillary thyroid carcinoma (PTC). A test for this mutation can increase the diagnostic accuracy of fine-needle aspiration cytology (FNAC), but a considerably high false-negative rate for the BRAF V600E mutation on FNAC has been reported. In this study, we investigated the risk factors associated with false-negative BRAF V600E mutation results on FNAC. BRAF V600E mutation results of 221 PTC nodules between December 2011 and June 2013 were retrospectively reviewed. BRAF V600E mutation results on both preoperative FNAC and postoperative formalin-fixed, paraffin-embedded (FFPE) samples were compared. We investigated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BRAF V600E mutation results on FNAC. And, we identified the risk factors associated with false-negative results. Of 221 PTC nodules, 150 (67.9%) on FNAC and 185 (83.7%) on FFPE samples were BRAF V600E mutation positive. The sensitivity, specificity, PPV, and NPV for BRAF V600E mutation testing with FNAC were 80.5, 97.2, 99.3, and 49.3%, respectively. Thirty-six (16.3%) BRAF V600E mutation-negative nodules on FNAC were mutation positive on FFPE sample analysis. Risk factors for these false-negative results were age, indeterminate FNAC results (nondiagnostic, atypia of undetermined significance (AUS), and findings suspicious for PTC), and PTC subtype. False-negative rate of BRAF mutation testing with FNAC for thyroid nodules is increased in cases of old age, indeterminate FNAC pathology results, and certain PTC subtypes. Therapeutic surgery can be considered for these cases. A well-designed prospective study with informed consent of patients will be essential for more informative results.

  20. Detecting and Treating Thyroid Nodules and Cancer Before, During, and After Pregnancy

    MedlinePlus

    ... nodules relies mainly on the results of thyroid ultrasound imaging and fine-needle aspiration biopsy . A biopsy is the removal of a small sample of the nodule for further testing. Thyroid ultrasound uses the same safe technique of high- frequency ...

  1. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    PubMed

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  2. SAME-DAY FINE-NEEDLE ASPIRATION CYTOLOGY DIAGNOSIS FOR THYROID NODULES ACHIEVES RAPID ANXIETY DECREASE AND HIGH DIAGNOSTIC ACCURACY.

    PubMed

    Lodewijk, Lutske; Vriens, Menno R; Vorselaars, Wessel M C M; van der Meij, Nick T M; Kist, Jakob W; Barentsz, Maarten W; Verkooijen, Helena M; Rinkes, Inne H M Borel; Valk, Gerlof D

    2016-05-01

    The time between the moment of referral for the diagnostic workup for thyroid nodules and the outcome can be worrisome for patients. In general, patients experience high levels of anxiety during the evaluation of a lesion suspicious for cancer. Therefore, the implementation of same-day fine-needle aspiration cytology (FNAC) diagnosis is becoming standard-of-care for many solid tumors. Our aim was to assess the feasibility of same-day FNAC diagnosis for thyroid nodules and to assess patient anxiety during the diagnostic process. For feasibility of same-day FNAC diagnosis, we assessed the proportion of patients receiving a diagnosis at the end of the visit. Accuracy was measured by comparing histology with the FNAC result. Patient anxiety was measured by the State Trait Anxiety Inventory at 6 moments during the diagnostic workup. Of the 131 included patients, 112 (86%) were female, and the mean age was 53 years. All patients, except those with a nondiagnostic FNAC result (n = 26; 20%), had a diagnosis at the end of the day. There were only two discordant results. Anxiety levels at the beginning of the day were high throughout the group, State Trait Anxiety Inventory (STAI) score 43.1 (SD 2.0) and decreased significantly more in patients with a benign FNAC result (STAI score 30.2), compared to patients with a malignant or indeterminate result (STAI score 39.6). Distress of patients with a thyroid nodule undergoing same-day FNAC diagnostics was high. Same-day FNAC diagnosis is feasible and accurate for the evaluation of thyroid nodules. Therefore, same-day FNAC diagnosis seems a safer, more patient-friendly approach to diagnose thyroid nodules.

  3. Melanoma metastases in regional lymph nodes are accurately detected by proton magnetic resonance spectroscopy of fine-needle aspirate biopsy samples.

    PubMed

    Stretch, Jonathan R; Somorjai, Ray; Bourne, Roger; Hsiao, Edward; Scolyer, Richard A; Dolenko, Brion; Thompson, John F; Mountford, Carolyn E; Lean, Cynthia L

    2005-11-01

    Nonsurgical assessment of sentinel nodes (SNs) would offer advantages over surgical SN excision by reducing morbidity and costs. Proton magnetic resonance spectroscopy (MRS) of fine-needle aspirate biopsy (FNAB) specimens identifies melanoma lymph node metastases. This study was undertaken to determine the accuracy of the MRS method and thereby establish a basis for the future development of a nonsurgical technique for assessing SNs. FNAB samples were obtained from 118 biopsy specimens from 77 patients during SN biopsy and regional lymphadenectomy. The specimens were histologically evaluated and correlated with MRS data. Histopathologic analysis established that 56 specimens contained metastatic melanoma and that 62 specimens were benign. A linear discriminant analysis-based classifier was developed for benign tissues and metastases. The presence of metastatic melanoma in lymph nodes was predicted with a sensitivity of 92.9%, a specificity of 90.3%, and an accuracy of 91.5% in a primary data set. In a second data set that used FNAB samples separate from the original tissue samples, melanoma metastases were predicted with a sensitivity of 87.5%, a specificity of 90.3%, and an accuracy of 89.1%, thus supporting the reproducibility of the method. Proton MRS of FNAB samples may provide a robust and accurate diagnosis of metastatic disease in the regional lymph nodes of melanoma patients. These data indicate the potential for SN staging of melanoma without surgical biopsy and histopathological evaluation.

  4. Introducing the reporting system for thyroid fine-needle aspiration cytology according to the new guidelines of the Japan Thyroid Association.

    PubMed

    Kakudo, Kennichi; Kameyama, Kaori; Miyauchi, Akira; Nakamura, Hirotoshi

    2014-01-01

    The Japan Thyroid Association (JTA) recently published new guidelines for clinical management of thyroid nodules. This paper introduces their diagnostic system for reporting thyroid fine-needle aspiration cytology. There are two points where the new reporting system that differs from existing internationally-accepted ones. The first is the subclassification of the so-called indeterminate category, which is divided into 'follicular neoplasm' and 'others'. The second is the subclassification of follicular neoplasm into 'favor benign', 'borderline' and 'favor malignant'. It is characterized by self-explanatory terminologies as to histological type and probability of malignancy to establish further risk stratification as well as to facilitate communication between clinicians and cytopathologists. The different treatment strategies adopted for thyroid nodules is deeply influenced by the particular diagnostic system used for thyroid cytology. In Western countries all patients with follicular neoplasms are advised to have immediate diagnostic surgery while patients in Japan often undergo further risk stratification without immediate surgery. The JTA diagnostic system of reporting thyroid cytology is designed for further risk stratification of patients with indeterminate cytology. If a surgeon applies diagnostic lobectomy to all patients with follicular neoplasm unselectively, this subclassification of follicular neoplasm has no practical meaning and is unnecessary. Cytological risk stratification of follicular neoplasms is optional and cytopathologists can choose either a simple 6-tier system without stratification of follicular neoplasm or a complicated 8-tier system depending on their experience in thyroid cytology and clinical management.

  5. Myoepithelial carcinoma of the parotid gland: A case of adequate fine-needle aspiration cytology specimens rendering a conclusive diagnosis possible.

    PubMed

    Guo, Xin; Watanabe, Jiro; Ariyasu, Sanae; Sasaguri, Yasuyuki; Kurose, Nozomu; Fukushima, Kei; Yamada, Sohsuke

    2018-01-01

    An 80-year-old male presented with a history of a hard right parotid mass that had gradually increased in size, with subsequent facial paralysis. A fine-needle aspiration biopsy was performed. The cytologic specimens contained a substantial number of sheet-like clusters or small groups of a mixture of plasmacytoid, oval to spindled, or large epithelioid cells having hyperchromatic pleomorphic nuclei, abundant cytoplasm with occasional inclusion body-like materials, and prominent nucleoli, in a relatively clear background. We first interpreted it as a carcinoma, suggestive of myoepithelial differentiation. Radical parotidectomy was performed, and a gross examination of the neoplasm revealed a non-capsulated and ill-defined tumor lesion, with a grayish or yellowish cut surface, associated with fat invasion. On a microscopic examination, the tumor was predominantly composed of the solid proliferation of atypical cells including a mixture of oval to spindled, plasmacytoid, or epithelioid cells, often arranged in a trabecular and reticular growth pattern with patchy eosinophilic hyalinized stroma. Immunohistochemistry showed that the carcinoma cells were specifically positive for p63, cytokeratins, and vimentin. Finally, electron microscopy demonstrated that their phenotype was consistent with a myoepithelial origin containing many bundles of variably thin actin filaments. Therefore, we finally made a diagnosis of myoepithelial carcinoma, defined as the malignant counterpart of benign myoepithelioma. We should be aware that owing to its characteristic cytological features, cytopathologists may be able to make a correct diagnosis of myoepithelial carcinoma, based on multiple and adequate samplings.

  6. A serious game for learning ultrasound-guided needle placement skills.

    PubMed

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  7. Molecular Nodal Staging Using miRNA Expression in Lung Cancer Patients by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration.

    PubMed

    Inage, Terunaga; Nakajima, Takahiro; Itoga, Sakae; Ishige, Takayuki; Fujiwara, Taiki; Sakairi, Yuichi; Wada, Hironobu; Suzuki, Hidemi; Iwata, Takekazu; Chiyo, Masako; Yoshida, Shigetoshi; Matsushita, Kazuyuki; Yasufuku, Kazuhiro; Yoshino, Ichiro

    2018-06-13

    The limited negative predictive value of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has often been discussed. The aim of this study was to identify a highly sensitive molecular biomarker for lymph node staging by EBUS-TBNA. Five microRNAs (miRNAs) (miR-200a, miR-200b, miR-200c, miR-141, and let-7e) were selected as biomarker candidates for the detection of nodal metastasis in a miRNA expression analysis. After having established a cutoff level of expression for each marker to differentiate malignant from benign lymph nodes among surgically dissected lymph nodes, the cutoff level was applied to snap-frozen EBUS-TBNA samples. Archived formalin-fixed paraffin- embedded (FFPE) samples rebiopsied by EBUS-TBNA after induction chemoradiotherapy were also analyzed. The expression of all candidate miRNAs was significantly higher in metastatic lymph nodes than in benign ones (p < 0.05) among the surgical samples. miR-200c showed the highest diagnostic yield, with a sensitivity of 95.4% and a specificity of 100%. When the cutoff value for miR-200c was applied to the snap-frozen EBUS-TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.4, 81.8, 95.0, 90.0, and 94.0%, respectively. For restaging FFPE EBUS- TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 60.0, 80.0, 100, and 84.6%, respectively. Among the restaged samples, 4 malignant lymph nodes were false negative by EBUS-TBNA, but they were accurately identified by miR-200c. miR-200c can be used as a highly sensitive molecular staging biomarker that will enhance nodal staging of lung cancer. © 2018 S. Karger AG, Basel.

  8. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  9. Fine-needle aspiration in desmoplastic small round cell tumor: a report of 10 new tumors in 8 patients with clinicopathological and molecular correlations with review of the literature.

    PubMed

    Klijanienko, Jerzy; Colin, Pierre; Couturier, Jérôme; Lagacé, Réal; Fréneaux, Paul; Pierron, Gaëlle; Laé, Marick; Klijanienko, Alice; Brisse, Hervé; Orbach, Daniel; Theocharis, Stamatios

    2014-05-01

    Desmoplastic small round cell tumor (DSRCT) is a rare round cell sarcoma entity characterized by a specific t(11;22)(p13;q12) translocation, usually intra-abdominal localization and an aggressive clinical outcome. To date, only 35 DSRCT cases diagnosed by fine-needle aspiration have been described. This study reports the cytological diagnosis of DSRCT. Ten tumors from 8 patients were sampled for diagnosis and analyzed to search the characteristic translocation using fluorescence in situ hybridization or reverse transcription polymerase chain reaction methods. Smears were always hypercellular and consisted of nonspecific round cell sarcoma. Nuclei were polymorphic round, kidney-, or heart-shaped. Nuclear molding was usually present. Paranuclear cytoplasmic densities were obvious and noted in 7 cases. Cytonuclear atypia, mitotic figures, numerous crushed nuclei, and apoptosis were frequently seen. Purple-stained stroma was present in 8 cases (ranging from few connective tissue fragments to large hyalinized deposits). Molecular studies based on cytological aspirates were performed in 8 patients. The presence of the fusion gene EWSR1-WT 1 transcript was identified in all, which confirmed the diagnosis of DSRCT. Smears showing poorly differentiated round cells associated with cytoplasmic densities and connective stoma, in a specific clinical context, young adult age, intra-abdominal localization, suggestive immunocytochemical profile, and a unique cytogenetic abnormality are highly specific and allow an accurate diagnosis of DSRCT. © 2014 American Cancer Society.

  10. Utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration in patients with mediastinal and hilar lymphadenopathy: Western region experience.

    PubMed

    Aljohaney, Ahmed A

    2018-01-01

    The aim of the study was to evaluate the clinical utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in patients with mediastinal and hilar lymphadenopathy and to explicitly describe the utility of this procedure in patient's outcome. A retrospective review and analysis was conducted on 52 patients with mediastinal or hilar lymphadenopathy who underwent EBUS-TBNA from June 2012 to June 2016. All the patients were evaluated by computed tomography (CT) chest with contrast before EBUS examination. Enlarged mediastinal or hilar lymph node was defined as >1 cm short axis on the enhanced CT. Among the 52 patients studied, 57.7% were presented with mediastinal or hilar lymphadenopathy for diagnosis and 42.3% presented with suspected mediastinal malignancy. Paratracheal stations were the most common site for puncture in 33 lymph nodes (43%). The best diagnostic yield was obtained from subcarinal stations and the lowest yield from the hilar stations. Surgical biopsies confirmed lymphoma in six patients, tuberculosis (TB) in three, sarcoidosis in two and one had metastatic adenocarcinoma of unknown primary. The sensitivity, specificity, positive predictive value, and negative predictive value of EBUS-TBNA for diagnosis of mediastinal and hilar lymph node abnormalities were 78.6%, 100%, 100%, and 80%, respectively. The diagnostic yield of EBUS-TBNA in malignant and benign conditions was 79.0%. EBUS-TBNA is a safe and efficacious procedure which can be performed using conscious sedation with high yields. It can be used for the staging of malignancies as well as for the diagnosis of inflammatory and infectious conditions such as sarcoidosis and TB.

  11. Adult granulosa cell tumor of the ovary: fine-needle-aspiration cytology of 10 cases and review of literature.

    PubMed

    Ali, Sarfraz; Gattuso, Paolo; Howard, Allison; Mosunjac, Marina B; Siddiqui, Momin T

    2008-05-01

    Adult granulosa cell tumor (GCT) of the ovary is mostly diagnosed in postmenopausal women. They typically secrete estrogen, which stimulates the endometrium to proliferate and cause abnormal bleeding. This study reviews the cytologic features of adult GCT of the ovary diagnosed by fine-needle aspiration (FNA). We reviewed slides from ten cases diagnosed by CT guided FNA from 1995 to 2007 at our institutions. Smears were stained with Diff-Quik and Papanicolaou stains. Patient's history and histologic diagnosis were also available and reviewed for all cases. The patients ranged in age from 39 to 83 yr. All 10 cases were hypercellular with both large and small overlapping cell clusters and individual cells. The cytologic features identified included: naked nuclei (10/10 cases), Call-Exner bodies (7/10 cases), blood vessels with prominent perivascular tumor cell growth (4/10 cases), spindle-shaped hyperchromatic stromal cells within cellular clusters (6/10 cases), mixed inflammation (3/10 cases), tumor cell necrosis (1/10 cases), and prominent metachromatic stroma seen in association with blood vessels (1/10 cases). Moderate to scant delicate cytoplasm was also seen (10/10 cases). Small, punctuate cytoplasmic vacuoles were also noted (7/10 cases) and were occasionally prominent (3/10 cases). In general nuclear to cytoplasmic ratios were high although lower than those typically seen in a lymphoma or small-cell carcinoma. Nuclei were generally centrally located although eccentrically located nuclei were consistently seen in a minority of cells. Nuclei were monotonous in size showing slightly convoluted (occasional rentiform and fetiform nuclei) to polygonal outlines. Prominent, central nucleoli were also seen (4/10 cases). Nuclear grooves were also seen (9/10 cases). No atypical mitotic activity was identified in any of the 10 cases (0/10 cases). In summary, the above cytologic features can also help in the cytologic diagnosis of adult GCTs.

  12. Randomized, open trial comparing a modified double-lumen needle follicular flushing system with a single-lumen aspiration needle in IVF patients with poor ovarian response.

    PubMed

    von Horn, Kyra; Depenbusch, Marion; Schultze-Mosgau, Askan; Griesinger, Georg

    2017-04-01

    Is a modified double-lumen aspiration needle system with follicular flushing able to increase the mean oocyte yield by at least one in poor response IVF patients as compared to single-lumen needle aspiration without flushing? Follicular flushing with the modified flushing system did not increase the number of oocytes, but increased the procedure duration. Most studies on follicular flushing were performed with conventional double-lumen needles in patients who were normal responders. Overall, these studies indicated no benefit of follicular flushing. Prospective, single-centre, randomized, controlled, open, superiority trial comparing the 17 G Steiner-Tan Needle® flushing system with a standard 17 G single-lumen aspiration needle (Gynetics®); time frame February 2015-March 2016. Eighty IVF patients, 18-45 years, BMI >18 kg/m2 to <35 kg/m2, presenting with ≤ five follicles >10 mm in both ovaries at the end of the follicular phase were randomized to either aspirating and flushing each follicle 3× with the Steiner-Tan-Needle® automated flushing system (n = 40) or a conventional single-lumen needle aspiration (n = 40). Primary outcome was the number of cumulus-oocyte-complexes (COCs). Procedure duration, burden (Depression Anxiety and Stress Scale; DASS-21) and post-procedure pain were also assessed. Flushing was not superior with a mean (SD) number of COCs of 2.4 (2.0) and 3.1 (2.3) in the Steiner-Tan Needle® and in the Gynectics® group, respectively (mean difference -0.7, 95% CI: 0.3 to -1.6; P = 0.27). Likewise no differences were observed in metaphase II  oocytes, two pronuclear oocytes, number of patients having an embryo transfer and DASS 21 scores. The procedure duration was significantly 2-fold increased. Testing for differences in the number of patients achieving an embryo transfer or differences in pregnancy rate would require a much larger sample size. The use of follicular flushing is unlikely to benefit the prognosis of patients with poor ovarian

  13. Thyroid fine-needle aspiration reporting rates and outcomes before and after Bethesda implementation within a combined academic and community hospital system.

    PubMed

    Harvey, Aaron M; Mody, Dina R; Amrikachi, Mojgan

    2013-11-01

    The current study compares data from our hospital system before and after the 2008 implementation of the Bethesda System for Reporting Thyroid Cytology (BSRTC). To show the effects the BSRTC has had on the reporting rates and outcomes for thyroid lesions. A search for thyroid fine-needle aspiration biopsies (FNABs) was performed for 2002-2005 (before BSRTC) and 2009-2011 (after BSRTC). Diagnostic outcomes were reviewed for cases with available follow-up. For 2002-2005, cytology reports for 3302 thyroid FNABs were reviewed, and 309 (9.4%) were classified as suspicious. For 2009-2011, cytology reports for 3432 thyroid FNABs were reviewed; 72 (2.1%) were classified as "atypia of undetermined significance or follicular lesion of undetermined significance" (AUS/FLUS), and 142 (4.1%) were classified as suspicious. Follow-up material was available for 31 AUS/FLUS cases (43.0%), and 6 of these cases (19%) were malignant. Follow-up material was available for 60 cases (42.3%) classified as suspicious, and 23 of these cases (38%) were malignant. The AUS/FLUS rate of 2.1% at our institution is at the lower range of the <7% recommended by the BSRTC, and our rate of 19% for risk of malignancy for AUS/FLUS is slightly above the BSRTC recommendation of 5% to 15%. Implementation of the BSRTC did not significantly affect our institution's reporting rates, most likely because an essentially similar classification system was employed before implementation of the BSRTC.

  14. Endoscopic ultrasound-guided techniques for diagnosing pancreatic mass lesions: Can we do better?

    PubMed Central

    Storm, Andrew C; Lee, Linda S

    2016-01-01

    The diagnostic approach to a possible pancreatic mass lesion relies first upon various non-invasive imaging modalities, including computed tomography, ultrasound, and magnetic resonance imaging techniques. Once a suspect lesion has been identified, tissue acquisition for characterization of the lesion is often paramount in developing an individualized therapeutic approach. Given the high prevalence and mortality associated with pancreatic cancer, an ideal approach to diagnosing pancreatic mass lesions would be safe, highly sensitive, and reproducible across various practice settings. Tools, in addition to radiologic imaging, currently employed in the initial evaluation of a patient with a pancreatic mass lesion include serum tumor markers, endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA). EUS-FNA has grown to become the gold standard in tissue diagnosis of pancreatic lesions. PMID:27818584

  15. The Role of Fine Needle Aspiration in the Diagnosis of Parotid Gland Tumors: Correlation With Preoperative Computerized Tomography Tumor Size.

    PubMed

    Ghantous, Yasmine; Naddaf, Raja; Barak, Michal; Abd-Elraziq, Murad; Abu Eln-Naaj, Imad

    2016-03-01

    The role of fine needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses is still controversial, regarding its sensitivity and specificity that vary between 41% and 100% and between 86% and 100% respectively.The aim of this study was to identify the specificity and sensitivity of FNAC of parotid gland tumors in relation to the tumor size as characterized preoperatively by computer tomography. The medical files of 79 patients whom were referred to the MaxilloFacila Surgery Department, Rambam medical center, over a 10.5-year period (2000-2010) were analyzed retrospectively.The extensity of the operation was determined by the location of the tumor as presented in computed tomography (CT) radiography, and preoperative FNAC examination.The majority of the masses were located in the superficial lobe (88.52%), and only 11.48% of the patients were located in the deep lobe (8:1 ratio). FNAC results were nondiagnostic in 7 patients (8.86%), 62 patients were diagnosed as inflammatory and benign lesion in (78.48%), malignant tumors were diagnosed in 10 patients (12.65%).The sensitivity in our study was 90%, the specificity was 98%, positive predictive value was 90%, negative predictive value was 98%, and diagnostic accuracy was 88%. The positive predictive value was 90%, the negative predictive value was 98%.Analyzing the effect of the preoperative CT size upon the accuracy of the FNAC diagnosis, we found that lesion with preoperative CT size greater than 24 mm has a more accurate FNAC result (P = 0.034).

  16. Molecular testing guidelines for lung adenocarcinoma: Utility of cell blocks and concordance between fine-needle aspiration cytology and histology samples

    PubMed Central

    Heymann, Jonas J.; Bulman, William A.; Maxfield, Roger A.; Powell, Charles A.; Halmos, Balazs; Sonett, Joshua; Beaubier, Nike T.; Crapanzano, John P.; Mansukhani, Mahesh M.; Saqi, Anjali

    2014-01-01

    Background: Lung cancer is a leading cause of mortality, and patients often present at a late stage. More recently, advances in screening, diagnosing, and treating lung cancer have been made. For instance, greater numbers of minimally invasive procedures are being performed, and identification of lung adenocarcinoma driver mutations has led to the implementation of targeted therapies. Advances in molecular techniques enable use of scant tissue, including cytology specimens. In addition, per recently published consensus guidelines, cytology-derived cell blocks (CBs) are preferred over direct smears. Yet, limited comparison of molecular testing of fine-needle aspiration (FNA) CBs and corresponding histology specimens has been performed. This study aimed to establish concordance of epidermal growth factor receptor (EGFR) and Kirsten rat sarcoma (KRAS) virus homolog testing between FNA CBs and histology samples from the same patients. Materials and Methods: Patients for whom molecular testing for EGFR or KRAS was performed on both FNA CBs and histology samples containing lung adenocarcinoma were identified retrospectively. Following microdissection, when necessary, concordance of EGFR and KRAS molecular testing results between FNA CBs and histology samples was evaluated. Results: EGFR and/or KRAS testing was performed on samples obtained from 26 patients. Concordant results were obtained for all EGFR (22/22) and KRAS (17/17) mutation analyses performed. Conclusions: Identification of mutations in lung adenocarcinomas affects clinical decision-making, and it is important that results from small samples be accurate. This study demonstrates that molecular testing on cytology CBs is as sensitive and specific as that on histology. PMID:24987443

  17. Aspiration cytology of mesenchymal hamartoma of the chest wall: a case report and literature review.

    PubMed

    Taweevisit, Mana; Trinavarat, Panruethai; Thorner, Paul Scott

    2014-10-01

    Mesenchymal hamartoma of the chest wall is a rare tumor-like lesion of infancy and childhood. The few available descriptions of the findings on fine needle aspiration list spindle-shaped cells and cartilage or chondromyxoid material as essential features for this diagnosis. An aggressive appearance on imaging studies and a lack of familiarity with this lesion, can lead the pathologist to misdiagnose the cytologic findings as malignancy. We reported a 5-month-old male presenting with a mass of the right chest wall progressively for 2 months. Radiologic studies showed a mixed solid and cystic mass originating from the third, fourth and fifth ribs, and a diagnosis of malignancy was favored. Fine needle aspiration recovered only spindle-shaped cells and a few multinucleated giant cells of osteoclast type. After a review of the imaging, a diagnosis of mesenchymal hamartoma of the chest wall was raised. This diagnosis was confirmed by pathologic examination of the subsequently resected mass. This is the sixth report of a mesenchymal hamartoma of the chest wall diagnosed by fine needle aspiration. This case illustrates that this diagnosis can be suspected in the absence of cartilage or chondromyxoid material, given appropriate clinical and radiologic findings. © 2014 Wiley Periodicals, Inc.

  18. Dedifferentiated liposarcoma and pleomorphic liposarcoma: a comparative study of cytomorphology and MDM2/CDK4 expression on fine-needle aspiration.

    PubMed

    Mariño-Enríquez, Adrián; Hornick, Jason L; Dal Cin, Paola; Cibas, Edmund S; Qian, Xiaohua

    2014-02-01

    Dedifferentiated liposarcoma (DDLPS) and pleomorphic liposarcoma (PLPS) are distinct high-grade liposarcomas. DDLPS is a nonlipogenic sarcoma characterized by amplification of MDM2 and CDK4. PLPS is a high-grade sarcoma containing lipoblasts, characterized by a complex karyotype and a more aggressive clinical course. Rarely, DDLPS shows lipogenic differentiation, mimicking PLPS. The cytomorphologic features of DDLPS and PLPS and the utility of ancillary studies have not been systemically analyzed. Cytologic preparations of 25 DDLPS and 13 PLPS, all histologically confirmed, were retrospectively reviewed along with clinical and cytogenetic data. Sample cellularity, vascular architecture, background material, predominant cell morphology, quality of the cytoplasm, and nuclear pleomorphism were compared for both tumor types. Immunohistochemistry for MDM2 and CDK4 was performed on cell blocks and/or core needle biopsies. Fine-needle aspirate smears from both DDLPS and PLPS were variably cellular, composed of cellular clusters and noncohesive cells. Abundant myxoid stroma was present in ∼25% of DDLPS and PLPS cases, whereas branching curvilinear vessels were more common in DDLPS than in PLPS (7 of 25 versus 2 of 13). Tumors were composed of predominantly spindled (18 of 25 DDLPS versus 3 of 13 PLPS) or epithelioid cells (7 of 25 DDLPS versus 6 of 13 PLPS). Pleomorphic cells were predominant in 3 PLPS, and were frequent in both (13 of 25 DDLPS versus 10 of 13 PLPS). The cytoplasm was mostly fibrillary and often vacuolated in both entities. Other features included necrosis, mitoses, and a prominent inflammatory infiltrate. The main cytologic differences were the presence of marked pleomorphism, abundant lipoblasts, and cells with microvacuolated cytoplasm in most PLPS. A total of 24 (96%) and 20 (80%) cases of DDLPS expressed MDM2 and CDK4, respectively, whereas none of the PLPS expressed both markers. Six DDLPS tested showed ring or giant marker chromosomes and/or MDM2

  19. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    PubMed

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart

  20. Electrolytic echo enhancement: a novel method to make needles more reflective to ultrasound.

    PubMed

    Cockburn, John F; Khosh, Stefan K

    2014-04-01

    This study examines the effect of augmenting the ultrasound reflectivity of needles using a novel electrolytic echo enhancement method. Needles were connected by a lead to the negative terminal of a 4.5 V direct current source. A grounding pad, connected to the positive terminal, was positioned on the undersurface of an ex vivo ox liver phantom. During needle insertion into the liver, electrolysis was induced creating a layer of gas on the needle electrode. Analysis of images showed a significant increase in needle brightness using electrolytic echo enhancement. Brightness was found to increase by a factor of ×3.6 compared with controls (P < 0.001). Electrolytic echo enhancement has the potential to make ultrasound-guided procedures safer and quicker for patients and increase the confidence of operators in their ability to see the whole needle including its tip. © 2014 The Royal Australian and New Zealand College of Radiologists.

  1. Use of high frequency ultrasound to monitor cervical lymph node alterations in mice.

    PubMed

    Walk, Elyse L; McLaughlin, Sarah; Coad, James; Weed, Scott A

    2014-01-01

    Cervical lymph node evaluation by clinical ultrasound is a non-invasive procedure used in diagnosing nodal status, and when combined with fine-needle aspiration cytology (FNAC), provides an effective method to assess nodal pathologies. Development of high-frequency ultrasound (HF US) allows real-time monitoring of lymph node alterations in animal models. While HF US is frequently used in animal models of tumor biology, use of HF US for studying cervical lymph nodes alterations associated with murine models of head and neck cancer, or any other model of lymphadenopathy, is lacking. Here we utilize HF US to monitor cervical lymph nodes changes in mice following exposure to the oral cancer-inducing carcinogen 4-nitroquinoline-1-oxide (4-NQO) and in mice with systemic autoimmunity. 4-NQO induces tumors within the mouse oral cavity as early as 19 wks that recapitulate HNSCC. Monitoring of cervical (mandibular) lymph nodes by gray scale and power Doppler sonography revealed changes in lymph node size eight weeks after 4-NQO treatment, prior to tumor formation. 4-NQO causes changes in cervical node blood flow resulting from oral tumor progression. Histological evaluation indicated that the early 4-NQO induced changes in lymph node volume were due to specific hyperproliferation of T-cell enriched zones in the paracortex. We also show that HF US can be used to perform image-guided fine needle aspirate (FNA) biopsies on mice with enlarged mandibular lymph nodes due to genetic mutation of Fas ligand (Fasl). Collectively these studies indicate that HF US is an effective technique for the non-invasive study of cervical lymph node alterations in live mouse models of oral cancer and other mouse models containing cervical lymphadenopathy.

  2. Short beveled sharp cutting needle is superior to facet tip needle for ultrasound-guided rectus sheath block in children with umbilical hernia: a case series.

    PubMed

    Alsaeed, A; Thallaj, A; Alzahrani, T; Khalil, N; Aljazaeri, A

    2014-10-01

    The most common peripheral nerve blocks used in umbilical hernia repair are rectus sheath block and regional block (caudal block). Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this study is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery, and to evaluate the easiness of soft tissue puncture and ultrasonic appearance of two different needle types. Twenty two (22) pediatric patients (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz linear probe. An ultrasound-guided rectus sheath block in the lateral edge of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). A 22 gauge short beveled sharp cutting needle 1.1 x 30 mm needle A (BD Insyte--W, Vialon material. Spain) was used in one side, and a Stimuplex A insulated Needle 22G 50mm (needle B) was used on the other side. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia were evaluated. Ultrasonograghic visualization of the posterior sheath was possible in all patients. Needle A scored 72.7% of excellent needle tip and shaft view (16 out of 22) compared to 63.63% for needle B (14 out of 22). None of the needles scored poor view. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one child who postoperatively requested morphine 0.1 mg/kg intravenously in recovery room. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia in the lateral edge of the rectus muscle. Use of the sharp short beveled needle of 22 gauge intravenous (IV) cannula stylet provides easy, less traumatic skin and rectus muscle

  3. Fuzzy method for pre-diagnosis of breast cancer from the Fine Needle Aspirate analysis

    PubMed Central

    2012-01-01

    Background Across the globe, breast cancer is one of the leading causes of death among women and, currently, Fine Needle Aspirate (FNA) with visual interpretation is the easiest and fastest biopsy technique for the diagnosis of this deadly disease. Unfortunately, the ability of this method to diagnose cancer correctly when the disease is present varies greatly, from 65% to 98%. This article introduces a method to assist in the diagnosis and second opinion of breast cancer from the analysis of descriptors extracted from smears of breast mass obtained by FNA, with the use of computational intelligence resources - in this case, fuzzy logic. Methods For data acquisition of FNA, the Wisconsin Diagnostic Breast Cancer Data (WDBC), from the University of California at Irvine (UCI) Machine Learning Repository, available on the internet through the UCI domain was used. The knowledge acquisition process was carried out by the extraction and analysis of numerical data of the WDBC and by interviews and discussions with medical experts. The PDM-FNA-Fuzzy was developed in four steps: 1) Fuzzification Stage; 2) Rules Base; 3) Inference Stage; and 4) Defuzzification Stage. Performance cross-validation was used in the tests, with three databases with gold pattern clinical cases randomly extracted from the WDBC. The final validation was held by medical specialists in pathology, mastology and general practice, and with gold pattern clinical cases, i.e. with known and clinically confirmed diagnosis. Results The Fuzzy Method developed provides breast cancer pre-diagnosis with 98.59% sensitivity (correct pre-diagnosis of malignancies); and 85.43% specificity (correct pre-diagnosis of benign cases). Due to the high sensitivity presented, these results are considered satisfactory, both by the opinion of medical specialists in the aforementioned areas and by comparison with other studies involving breast cancer diagnosis using FNA. Conclusions This paper presents an intelligent method to

  4. Clinical decision-making in atypical and suspicious categories in fine-needle aspiration cytology of the breast.

    PubMed

    Gipponi, Marco; Fregatti, Piero; Garlaschi, Alessandro; Calabrese, Massimo; Baccini, Paola; Gallo, Maurizio; Murelli, Federica; Margarino, Cecilia; Bobbio, Carolina; Friedman, Daniele

    2015-04-01

    Fine-needle aspiration cytology (FNAC) is a simple and reliable technique to assess breast lesions, although a definitive differential diagnosis (benignity vs. cancer) is achieved approximately in 60-70% of cases because an inadequate (C1), atypical (C3) or suspicious (C4) category is otherwise reported. A retrospective analysis of 763 cases with C3 or C4 reports was performed to define their positive predictive value (PPV), as well as the practical implications of clinical and imaging findings as for clinical decision-making. FNACs were collected from January 2003 to September 2012 at the Breast Unit of IRCCS "A.O.U. San Martino-IST" Genoa, with each being received later to definitive histology. The PPV for cancer of C3/C4 categories were computed to measure the accuracy of FNAC; moreover, the PPV was also stratified according to clinical, mammography and sonography data alone or by their combination. The PPV of C3 and C4 was 21.1% (80/380) and 84.1 % (322/383), respectively. Within each C3/C4 category, a significant direct correlation (p<0.001) between the suspicion index of clinical, mammography and sonography data and cancer detection rate was always observed. The PPV of C3/C4 stratified by the combination of clinical and imaging findings showed satisfactory values in the C3 category only when there was an agreement between clinical and imaging findings, whereas the PPV of the C4 category was always remarkably high (ranging from 92.3% to 100%). the diagnostic work-up in C4 reports or in patients with a C3 report but with an high suspicion index at clinical or imaging examination should be preferably implemented by means of a core biopsy to optimize the therapeutic planning; given a C3 report with dubious clinical and/or imaging findings, an excisional biopsy (or in alternative vacuum-assisted breast biopsy with complete removal of the nodule) should be preferably performed in order to reach a definitive histological dia gnosis with no further delay. Copyright

  5. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Increases the Yield of Transbronchial Lung Biopsy for the Evaluation of Peribronchial Lesions

    PubMed Central

    Chen, Cheng; Mu, Chuan-Yong; Su, Mei-Qin; Mao, Jing-Yu; Zhu, Ye-Han; Huang, Jian-An

    2017-01-01

    Background: Due to absence of visible endobronchial target, the diagnostic yield of flexible bronchoscopy for peribronchial lesions has been unsatisfactory. Convex probe endobronchial ultrasound (CP-EBUS) has allowed for performing real-time transbronchial needle aspiration (TBNA) of enlarged hilar and mediastinal lymph nodes and therefore could also be used as a means of diagnosing proximal peribronchial lesions. Methods: We retrospectively analyzed the results related to 72 patients who underwent CP-EBUS for peribronchial lesions without endobronchial involvement and adjacent to three-grade bronchi based on chest computed tomography (CT) scan. We recorded the images during EBUS as well as the diagnostic results of TBNA and conventional-transbronchial lung biopsy/brush (C-TBLB/b), and final diagnoses were based on pathologic analysis and follow-up. Results: In all cases, the mass was able to be identified using EBUS in 97.2% patients (70/72) who were performed with EBUS-TBNA + C-TBLB/b. Sixty-six patients had a final diagnosis, 80.0% patients (56/70) had malignancies, and 14.3% patients (10/70) had benign disease. In malignancies, the diagnostic yield of C-TBLB/b was 57.1% (32/56) and in EBUS-TBNA was 85.7% (48/56), whereas pathologic diagnosis reached 94.6% when EBUS-TBNA was combined with C-TBLB/b. C-TBLB/b + EBUS-TBNA also exhibited stronger potency of histolytic diagnosis for malignancies than either EBUS-TBNA or C-TBLB/b alone. Furthermore, there are data supporting the value of EBUS-TBNA for the diagnosis of benign lung disease. Conclusion: The combined endoscopic approach with EBUS-TBNA and C-TBLB/b is an accurate and effective method for the evaluation of peribronchial lesions, with better results than using each technique alone. PMID:28051017

  6. Randomized Trial of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration With and Without Rapid On-site Evaluation for Lung Cancer Genotyping.

    PubMed

    Trisolini, Rocco; Cancellieri, Alessandra; Tinelli, Carmine; de Biase, Dario; Valentini, Ilaria; Casadei, Gianpiero; Paioli, Daniela; Ferrari, Franco; Gordini, Giovanni; Patelli, Marco; Tallini, Giovanni

    2015-12-01

    Experts and scientific society guidelines recommend that rapid on-site evaluation (ROSE) be used with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) to optimize lung cancer genotyping, but no comparative trial has been carried out to confirm and quantify its usefulness. To assess the influence of ROSE on the yield of EBUS-TBNA for a multigene molecular analysis of lung cancer samples, consecutive patients with suspected or known advanced lung cancer were randomized to undergo EBUS-TBNA without ROSE (EBUS arm) or with ROSE (ROSE arm). The primary end point was the rate of the successful accomplishment of the institution's clinical protocol for molecular profiling of nonsquamous non-small cell lung cancer (EGFR and KRAS testing, followed by ALK testing for tumors with EGFR and KRAS wild-type status). Complete genotyping was achieved in 108 of 126 patients (85.7%) (90.8% in the ROSE arm vs 80.3% in the EBUS arm, P = .09). The patients in the ROSE arm were less likely to have samples that could be used only for pathologic diagnosis because of minimal tumor burden (0 vs 6, P = .05), and were more likely to have the bronchoscopy terminated after a single biopsy site (58.9% vs 44.1%, P = .01). ROSE prevents the need for a repeat invasive diagnostic procedure aimed at molecular profiling in at least one out of 10 patients with advanced lung cancer and significantly reduces the risk of retrieving samples that can be used only for pathologic subtyping because of minimal tumor burden. ClinicalTrials.gov; No.: NCT01799382; URL: www.clinicaltrials.gov.

  7. The sensitivity of motor response to needle nerve stimulation during ultrasound guided interscalene catheter placement.

    PubMed

    Fredrickson, Michael J

    2008-01-01

    Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.

  8. Development of a Novel Ultrasound-guided Peritonsillar Abscess Model for Simulation Training.

    PubMed

    Ng, Vivienne; Plitt, Jennifer; Biffar, David

    2018-01-01

    Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments.1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition.6-9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. Forty-six emergency medicine (EM) residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41). They found the model realistic (mean 3.73) and easy to use (mean 4.08). Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing on the trainer. This low-cost, easy

  9. FNAC Versus Core Needle Biopsy: A Comparative Study in Evaluation of Palpable Breast Lump

    PubMed Central

    Saha, Abhijit; Mukhopadhyay, Madhumita; Sarkar, Koushik; Saha, Ashis Kumar; Sarkar, Diptendra KR

    2016-01-01

    Introduction Breast carcinoma is the most common malignant tumour and the leading cause of carcinoma death in women in world. The main purpose of FNAC or CNB of breast lumps is to confirm cancer preoperatively and to avoid unnecessary surgery in specific benign conditions. Aims and Objective The objective of the study was to compare between Fine Needle Aspiration Cytology (FNAC) and Core Needle Biopsy (CNB) in the diagnosis of breast carcinoma with final histological diagnosis from excision specimen as it is gold standard. Materials and Methods A prospective study was done on 50 cases. Patients undergoing all three procedures (Fine Needle Aspiration Cytology and Core Needle Biopsy done at Department of Pathology; subsequent excision surgeries done at Department of General Surgery) were selected. May Grunwald Giemsa (MGG) and Papaniculou (PAP) staining were performed on cytology smears. Haematoxylin and Eosin (H&E) staining was done on both the CNB and tissue specimens obtained from subsequent excision surgeries to see the histological features. Results FNAC showed sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 69%, 100%, 100%, 38.1%, and 74% respectively in diagnosing carcinoma. CNB had sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 88.3%, 100%, 100%, 53.3% and 86%. Both FNAC and CNB showed statistically significant correlation with confirmatory HPE of excision specimen (p-value <0.05) in the diagnosis of breast carcinoma. Conclusion Fine needle aspiration cytology (FNAC) is a rapid, less complicated, economical, reliable and relevant method for the preoperative pathological diagnosis of breast carcinoma in a developing nation like ours. If the initial FNAC is inadequate, core needle biopsy (CNB) can be a useful second line method of pathological diagnosis in order to minimize the chance of missed diagnosis of breast cancer. PMID:27042469

  10. A birth in non-mosaic Klinefelter's syndrome after testicular fine needle aspiration, intracytoplasmic sperm injection and preimplantation genetic diagnosis.

    PubMed

    Reubinoff, B E; Abeliovich, D; Werner, M; Schenker, J G; Safran, A; Lewin, A

    1998-07-01

    Non-mosaic Klinefelter patients are generally azoospermic due to primary testicular failure. Nevertheless, in some cases, testicular spermatozoa may be recovered and utilized to fertilize oocytes via intracytoplasmic sperm injection (ICSI). As the risk for an increased number of gonosomes in these spermatozoa is unclear, preimplantation genetic diagnosis (PGD) may be attempted in the resulting embryos. In the present study, we report our experience with the combined approach of sperm retrieval by testicular fine needle aspiration (FNA), ICSI and PGD in seven consecutive non-mosaic Klinefelter individuals. In four patients, between one and five spermatozoa were retrieved in five out of nine consecutive attempts. In a fifth patient, only 10 round spermatids could be isolated. Mature spermatozoa were injected into a total of 16 metaphase-II oocytes, of which 11 (69%) remained intact. Two distinct pronuclei (2PN) were observed in four oocytes (36%) while a single pronucleus (1PN) was documented in two oocytes. Five cleavage stage embryos developed from the oocytes of two couples. Upon the request of one couple, their three embryos (two derived from 1PN oocytes) were transferred without PGD but pregnancy was not achieved. PGD by fluorescence in-situ hybridization (FISH) was performed in the two embryos of the other couple which were derived from normal fertilization. PGD results of one embryo were 18,18,X,X,Y, the embryo was not transferred and FISH analysis of the remaining blastomeres identified variable chromosome numbers in the nuclei. The second embryo was diagnosed as normal and was transferred, resulting in a successful pregnancy and birth. In conclusion, the results of this report indicate that a pregnancy and birth may be attained in azoospermic non-mosaic Klinefelter individuals by testicular FNA combined with ICSI. Due to the unknown risk of gonosomes aneuploidy in embryos from Klinefelter patients, PGD or prenatal diagnosis should be recommended.

  11. Assessment of cellularity, genomic DNA yields, and technical platforms for BRAF mutational testing in thyroid fine-needle aspirate samples.

    PubMed

    Dyhdalo, Kathryn; Macnamara, Stephen; Brainard, Jennifer; Underwood, Dawn; Tubbs, Raymond; Yang, Bin

    2014-02-01

    BRAF mutation V600E (substitution Val600Glu) is a molecular signature for papillary thyroid carcinoma (PTC). Testing for BRAF mutation is clinically useful in providing prognostic prediction and facilitating accurate diagnosis of PTC in thyroid fine-needle aspirate (FNA) samples. This study assessed the correlation of cellularity with DNA yield and compared 2 technical platforms with different sensitivities in detection of BRAF mutation in cytologic specimens. Cellularity was evaluated based on groups of 10+ cells on a ThinPrep slide: 1+ (1-5 groups), 2+ (6-10 groups), 3+ (11-20 groups), and 4+ (> 20 groups). Genomic DNA was extracted from residual materials of thyroid FNAs after cytologic diagnosis. Approximately 49% of thyroid FNA samples had low cellularity (1-2+). DNA yield is proportionate with increased cellularity and increased nearly 4-fold from 1+ to 4+ cellularity in cytologic samples. When applied to BRAF mutational assay, using a cutoff of 6 groups of follicular cells with 10+ cells per group, 96.7% of cases yielded enough DNA for at least one testing for BRAF mutation. Five specimens (11.6%) with lower cellularity did not yield sufficient DNA for duplicate testing. Comparison of Sanger sequencing to allele-specific polymerase chain reaction methods shows the latter confers better sensitivity in detection of BRAF mutation, especially in limited cytologic specimens with a lower percentage of malignant cells. This study demonstrates that by using 6 groups of 10+ follicular cells as a cutoff, nearly 97% of thyroid FNA samples contain enough DNA for BRAF mutational assay. Careful selection of a molecular testing system with high sensitivity facilitates the successful conduction of molecular testing in limited cytologic specimens. Cancer (Cancer Cytopathol) 2014;122:114-22 © 2013 American Cancer Society. © 2013 American Cancer Society.

  12. Endoscopic Ultrasound of the Upper Gastrointestinal Tract and Mediastinum: Diagnosis and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prasad, Priyajit; Wittmann, Johannes; Pereira, Stephen P.

    2006-12-15

    Endoscopic ultrasound (EUS) has developed significantly over the last two decades and has had a considerable impact on the imaging and staging of mass lesions within or in close proximity to the gastrointestinal (GI) tract. In conjunction with conventional imaging such as helical computed tomography and magnetic resonance imaging, the indications for EUS include (1) differentiating between benign and malignant lesions of the mediastinum and upper GI tract, (2) staging malignant tumors of the lung, esophagus, stomach, and pancreas prior to surgery or oncological treatment, (3) excluding common bile duct stones before laparoscopic cholecystectomy, thereby avoiding the need for endoscopicmore » retrograde cholangiopancreatography (ERCP) in some patients, and (4) assessing suspected lesions that are either equivocal or not seen on conventional imaging. In recent years, EUS has charted a course similar to that taken by ERCP, evolving from a purely diagnostic modality to one that is interventional and therapeutic. These indications include (5) obtaining a tissue diagnosis by EUS-guided fine-needle aspiration or trucut-type needle biopsy and (6) providing therapy such as coeliac plexus neurolysis and pancreatic pseudocyst drainage-in many cases, more accurately and safely than conventional techniques. Emerging investigational techniques include EUS-guided enteric anastomosis formation and fine-needle injection therapy for malignant disease.« less

  13. From Mount Sinai to Mount Scopus: differences in the role and value of fine needle aspiration for evaluating thyroid nodules.

    PubMed

    Mazeh, Haggi; Greenstein, Alexander; Swedish, Kristin; Arora, Shalini; Hermon, Hila; Ariel, Ilana; Divino, Celia; Freund, Herbert R; Weber, Kaare

    2009-05-01

    Fine needle aspiration is the main diagnostic tool used to assess thyroid nodules. To correlate FNA cytology results with surgical pathological findings in two teaching medical centers across the Atlantic. We retrospectively identified 484 patients at Hadassah Hebrew University Medical Center, Jerusalem and Mount Sinai Hospital, New York, by means of both preoperative FNA cytology and a final histopathological report. Results compared FNA diagnosis, histological findings and frozen section results (Mt. Sinai only). The sensitivity value of FNA at Hadassah was 83.0% compared with 79.1% at Mt. Sinai (NS). Specificity values were 86.6 vs. 98.5% (P < 0.05), negative predictive value 78.7 vs. 77.6% (NS) and positive predictive value 89.7 vs. 98.6% (P < 0.05), respectively. "Follicular lesion" was diagnosed on FNA in 33.1% of the patients at Hadassah and in 21.5% at Mt Sinai (P < 0.005) with a malignancy rate of 42.5 vs. 23.1% (P < 0.05), respectively. Frozen section was used in 190 patients at Mt. Sinai (78.5%) with sensitivity and specificity values of 72.3% and 100%. Frozen section results altered the planned operative course in only 6 patients (2.5%). Follicular carcinoma was diagnosed in 12 patients at Hadassah vs. 2 patients at Mt. Sinai (P < 0.05). The sensitivity of FNA at the two institutions was comparable. While malignancy on frozen section is highly specific, it should be used selectively for suspicious FNA results. Follicular lesions and the rate of malignancy in such lesions were more common at Hadassah, favoring a more aggressive surgical approach.

  14. Benefits and limitations of fine needle aspiration cytology in the diagnosis and classification of leprosy in primary and secondary healthcare settings.

    PubMed

    Ray, R; Mondal, R K; Pathak, S

    2015-08-01

    The goal of the World Health Organization (WHO) is to eliminate leprosy as a public health problem. This will only be possible when all patients are detected and cured using multidrug therapy, which requires accurate diagnosis prior to treatment. The objective of this study was to evaluate the possibility of the diagnosis of leprosy lesions by fine needle aspiration cytology according to a modification of the Ridley-Jopling scale, as it can be used in primary and secondary healthcare centres, especially in low-resource settings in which leprosy is prevalent. A prospective study comprising 54 cases with cardinal features of leprosy was performed. Among the 54 cases, 27 patients consented to a histopathological biopsy procedure. The slides were stained with Giemsa, modified Ziehl-Neelsen, Papanicolaou and haematoxylin and eosin methods. Among the 54 cases, 34 were reported as tuberculoid leprosy, five as mid-borderline (BB), three as borderline lepromatous (BL) and eight as lepromatous leprosy (LL); four were unsatisfactory. Histopathological study was performed in 27 cases, which showed cyto-histological correlation in 21 cases (78%). Agreement between histological and cytological diagnosis was achieved in 12 of the 15 tuberculoid cases, one of the three BB cases, one of the two BL cases and all seven LL cases. With the implementation of the WHO classification based on patch counting, there is the possibility of the over-treatment of paucibacillary cases and under-treatment of multibacillary cases. Cytology in terms of cellular type morphology and bacteriological study can complement the WHO classification. © 2014 John Wiley & Sons Ltd.

  15. Modeling, Production, and Testing of an Echogenic Needle for Ultrasound-Guided Nerve Blocks.

    PubMed

    Bigeleisen, Paul E; Hess, Aaron; Zhu, Richard; Krediet, Annelot

    2016-06-01

    We have designed, produced, and tested an echogenic needle based on a sawtooth pattern where the height of the tooth was 1.25 times the wavelength of the ultrasound transducer. A numeric solution to the time-independent wave equation (Helmholtz equation) was used to create a model of backscattering from a needle. A 21-gauge stainless steel prototype was manufactured and tested in a water bath. Backscattering from the needle was compared to theoretical predications from our model. Based on these results, an 18-gauge prototype needle was fabricated from stainless steel and tested in a pig cadaver. This needle was compared to a commercial 18-gauge echogenic needle (Pajunk Medical Systems, Tucker, GA) by measuring the brightness of the needle relative to the background of sonograms of a needle in a pig cadaver. The backscattering from the 21-gauge prototype needle reproduced the qualitative predictions of our model. At 30° and 45° of insonation, our prototype performed equivalently to the Pajunk needle. At 60°, our prototype was significantly brighter than the Pajunk needle (P = .017). In conclusion, we chose a model for the design of an echogenic needle and modeled it on the basis of a solution to the Helmholtz equation. A prototype needle was tested in a water bath and compared to the model prediction. After verification of our model, we designed an 18-gauge needle, which performed better than an existing echogenic needle (Pajunk) at 60° of insonation. Our needle will require further testing in human trials. © 2016 by the American Institute of Ultrasound in Medicine.

  16. Three-dimensional virtual bronchoscopy using a tablet computer to guide real-time transbronchial needle aspiration.

    PubMed

    Fiorelli, Alfonso; Raucci, Antonio; Cascone, Roberto; Reginelli, Alfonso; Di Natale, Davide; Santoriello, Carlo; Capuozzo, Antonio; Grassi, Roberto; Serra, Nicola; Polverino, Mario; Santini, Mario

    2017-04-01

    We proposed a new virtual bronchoscopy tool to improve the accuracy of traditional transbronchial needle aspiration for mediastinal staging. Chest-computed tomographic images (1 mm thickness) were reconstructed with Osirix software to produce a virtual bronchoscopic simulation. The target adenopathy was identified by measuring its distance from the carina on multiplanar reconstruction images. The static images were uploaded in iMovie Software, which produced a virtual bronchoscopic movie from the images; the movie was then transferred to a tablet computer to provide real-time guidance during a biopsy. To test the validity of our tool, we divided all consecutive patients undergoing transbronchial needle aspiration retrospectively in two groups based on whether the biopsy was guided by virtual bronchoscopy (virtual bronchoscopy group) or not (traditional group). The intergroup diagnostic yields were statistically compared. Our analysis included 53 patients in the traditional and 53 in the virtual bronchoscopy group. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the traditional group were 66.6%, 100%, 100%, 10.53% and 67.92%, respectively, and for the virtual bronchoscopy group were 84.31%, 100%, 100%, 20% and 84.91%, respectively. The sensitivity ( P  = 0.011) and diagnostic accuracy ( P  = 0.011) of sampling the paratracheal station were better for the virtual bronchoscopy group than for the traditional group; no significant differences were found for the subcarinal lymph node. Our tool is simple, economic and available in all centres. It guided in real time the needle insertion, thereby improving the accuracy of traditional transbronchial needle aspiration, especially when target lesions are located in a difficult site like the paratracheal station. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Gestrinone combined with ultrasound-guided aspiration and ethanol injection for treatment of chocolate cyst of ovary.

    PubMed

    Wu, Xiaoyun; Xu, Yun

    2015-05-01

    The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  18. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    NASA Astrophysics Data System (ADS)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  19. Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy.

    PubMed

    Kuang, Y; Hilgers, A; Sadiq, M; Cochran, S; Corner, G; Huang, Z

    2016-07-01

    Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications. Copyright © 2016 The Authors. Published by Elsevier B

  20. Use of High Frequency Ultrasound to Monitor Cervical Lymph Node Alterations in Mice

    PubMed Central

    Walk, Elyse L.; McLaughlin, Sarah; Coad, James; Weed, Scott A.

    2014-01-01

    Cervical lymph node evaluation by clinical ultrasound is a non-invasive procedure used in diagnosing nodal status, and when combined with fine-needle aspiration cytology (FNAC), provides an effective method to assess nodal pathologies. Development of high-frequency ultrasound (HF US) allows real-time monitoring of lymph node alterations in animal models. While HF US is frequently used in animal models of tumor biology, use of HF US for studying cervical lymph nodes alterations associated with murine models of head and neck cancer, or any other model of lymphadenopathy, is lacking. Here we utilize HF US to monitor cervical lymph nodes changes in mice following exposure to the oral cancer-inducing carcinogen 4-nitroquinoline-1-oxide (4-NQO) and in mice with systemic autoimmunity. 4-NQO induces tumors within the mouse oral cavity as early as 19 wks that recapitulate HNSCC. Monitoring of cervical (mandibular) lymph nodes by gray scale and power Doppler sonography revealed changes in lymph node size eight weeks after 4-NQO treatment, prior to tumor formation. 4-NQO causes changes in cervical node blood flow resulting from oral tumor progression. Histological evaluation indicated that the early 4-NQO induced changes in lymph node volume were due to specific hyperproliferation of T-cell enriched zones in the paracortex. We also show that HF US can be used to perform image-guided fine needle aspirate (FNA) biopsies on mice with enlarged mandibular lymph nodes due to genetic mutation of Fas ligand (Fasl). Collectively these studies indicate that HF US is an effective technique for the non-invasive study of cervical lymph node alterations in live mouse models of oral cancer and other mouse models containing cervical lymphadenopathy. PMID:24955984

  1. Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces

    PubMed Central

    Abayazid, Momen; Moreira, Pedro; Shahriari, Navid; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    In this paper, we present a system capable of automatically steering a bevel-tipped flexible needle under ultrasound guidance toward a physical target while avoiding a physical obstacle embedded in gelatin phantoms and biological tissue with curved surfaces. An ultrasound pre-operative scan is performed for three-dimensional (3D) target localization and shape reconstruction. A controller based on implicit force control is developed to align the transducer with curved surfaces to assure the maximum contact area, and thus obtain an image of sufficient quality. We experimentally investigate the effect of needle insertion system parameters such as insertion speed, needle diameter and bevel angle on target motion to adjust the parameters that minimize the target motion during insertion. A fast sampling-based path planner is used to compute and periodically update a feasible path to the target that avoids obstacles. We present experimental results for target reconstruction and needle insertion procedures in gelatin-based phantoms and biological tissue. Mean targeting errors of 1.46 ± 0.37 mm, 1.29 ± 0.29 mm and 1.82 ± 0.58 mm are obtained for phantoms with inclined, curved and combined (inclined and curved) surfaces, respectively, for insertion distance of 86–103 mm. The achieved targeting errors suggest that our approach is sufficient for targeting lesions of 3 mm radius that can be detected using clinical ultrasound imaging systems. PMID:25455165

  2. Fine Needle Aspiration

    MedlinePlus

    ... Humanitarian Efforts International Outreach Advocacy Board of Governors Industry Programs Professional Development Home AcademyU Home Study Course Maintenance of Certification Conferences & Events Practice Management Home Resources ...

  3. Fine Needle Aspiration

    MedlinePlus

    ... Programs Professional Development Home AcademyU Home Study Course Maintenance of Certification Conferences & Events Practice Management Home Resources Quality Clinical Data Registry Research Reimbursement ...

  4. Thyroid Fine-Needle Aspiration Cytology:Causes of false-positive results.

    PubMed

    Malheiros, Daniela C; Canberk, Sule; Poller, David N; Schmitt, Fernando

    2018-05-16

    In this paper, we aim to focus on false positive results in the evaluation of thyroid aspirations, covering cystic, inflammatory, follicular and oncocytic lesions, papillary carcinoma, and medullary carcinoma of thyroid. The recently described entity, "noninvasive follicular thyroid neoplasm with papillary-like nuclear features" (NIFTP), is also discussed detailing the impact of its introduction on the sensitivity and specificity of thyroid FNA, as well as the use of molecular tests for diagnostics. Medicolegal issues in relation to current practice in English law are also described. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Benchmarking of state-of-the-art needle detection algorithms in 3D ultrasound data volumes

    NASA Astrophysics Data System (ADS)

    Pourtaherian, Arash; Zinger, Svitlana; de With, Peter H. N.; Korsten, Hendrikus H. M.; Mihajlovic, Nenad

    2015-03-01

    Ultrasound-guided needle interventions are widely practiced in medical diagnostics and therapy, i.e. for biopsy guidance, regional anesthesia or for brachytherapy. Needle guidance using 2D ultrasound can be very challenging due to the poor needle visibility and the limited field of view. Since 3D ultrasound transducers are becoming more widely used, needle guidance can be improved and simplified with appropriate computer-aided analyses. In this paper, we compare two state-of-the-art 3D needle detection techniques: a technique based on line filtering from literature and a system employing Gabor transformation. Both algorithms utilize supervised classification to pre-select candidate needle voxels in the volume and then fit a model of the needle on the selected voxels. The major differences between the two approaches are in extracting the feature vectors for classification and selecting the criterion for fitting. We evaluate the performance of the two techniques using manually-annotated ground truth in several ex-vivo situations of different complexities, containing three different needle types with various insertion angles. This extensive evaluation provides better understanding on the limitations and advantages of each technique under different acquisition conditions, which is leading to the development of improved techniques for more reliable and accurate localization. Benchmarking results that the Gabor features are better capable of distinguishing the needle voxels in all datasets. Moreover, it is shown that the complete processing chain of the Gabor-based method outperforms the line filtering in accuracy and stability of the detection results.

  6. Needle Steering in Biological Tissue using Ultrasound-based Online Curvature Estimation

    PubMed Central

    Moreira, Pedro; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2014-01-01

    Percutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes. Accurate placement of the needle tip is important to the success of many needle procedures. The current needle steering systems depend on needle-tissue-specific data, such as maximum curvature, that is unavailable prior to an interventional procedure. In this paper, we present a novel three-dimensional adaptive steering method for flexible bevel-tipped needles that is capable of performing accurate tip placement without previous knowledge about needle curvature. The method steers the needle by integrating duty-cycled needle steering, online curvature estimation, ultrasound-based needle tracking, and sampling-based motion planning. The needle curvature estimation is performed online and used to adapt the path and duty cycling. We evaluated the method using experiments in a homogenous gelatin phantom, a two-layer gelatin phantom, and a biological tissue phantom composed of a gelatin layer and in vitro chicken tissue. In all experiments, virtual obstacles and targets move in order to represent the disturbances that might occur due to tissue deformation and physiological processes. The average targeting error using our new adaptive method is 40% lower than using the conventional non-adaptive duty-cycled needle steering method. PMID:26229729

  7. Breast fine-needle aspiration samples reported as "proliferative breast lesion": clinical utility of the subcategory "proliferative breast lesion with atypia".

    PubMed

    Zhao, Chengquan; Raza, Anwar; Martin, Sue E; Pan, Jiangqiu; Greaves, Timothy S; Cobb, Camilla J

    2009-04-25

    The fine-needle aspiration (FNA) diagnosis of proliferative breast lesion is an indeterminate category. The aim of this correlative study was to determine whether a subcategory of "proliferative breast lesion with atypia" was achievable and whether this subcategory has management utility. Breast FNA cases from 2000 through 2005 diagnosed as proliferative breast lesion and proliferative breast lesion with atypia were retrieved. Both cytologic and surgical slides of these cases were reviewed blindly. A cytologic diagnosis of proliferative breast lesion (without atypia) or proliferative breast lesion with atypia was used if the findings of the proliferative breast lesion did not fit a more specific category. Of the 3934 breast FNAs performed on palpable breast masses from January 2000 to December 2005 at the LAC + USC Medical Center, 317 (8.1%) were diagnosed cytologically as proliferative breast lesion with atypia, without atypia or without mention of atypia. There was subsequent histopathology on 201 of these cases. After the cytologic smears were reviewed, 29 cases were excluded from this study. Of the 172 remaining cases, 21 (12.2%) were found to be malignant and the remaining 151 (87.8%) were found to be benign on histology. Of the malignant cases, 90% had an FNA diagnosis of proliferative breast lesion with atypia; of the benign cases, 78% were interpreted as proliferative breast lesion without atypia. Proliferative breast lesion with atypia was clinically significant because it was associated with a significantly increased likelihood of malignancy compared with proliferative breast lesion without atypia. Most of the malignancies had hypocellularity or low nuclear grade on the FNA smears. Fibroadenoma accounted for most of the benign lesions in both proliferative breast lesion and proliferative breast lesion with atypia. (c) 2009 American Cancer Society.

  8. Thyroid nodule management: clinical, ultrasound and cytopathological parameters for predicting malignancy

    PubMed Central

    Maia, Frederico F. R.; Zantut-Wittmann, Denise Engelbrecht

    2012-01-01

    Although fine-needle aspiration cytology is considered to be the reference method for evaluating thyroid nodules, the results are inaccurate in approximately 10-30% of cases. Several studies have attempted to predict the risk of malignancy in thyroid nodules based on age, nodularity, thyrotropin values, thyroid autoimmune disease, hot/cold nodule status, and ultrasound parameters. However, no consensus has been found, and none of these parameters has significantly affected patient management. The management of indeterminate thyroid nodules and re-biopsies of nodules with initially benign cytological results remain important and controversial topics of discussion. The Bethesda cytological system and several studies on the use of molecular markers to predict malignancy from cytological samples of thyroid nodules need further clarification. More in-depth discussions among and continuous education of the specialists involved in treating thyroid disease are necessary to improve the management of these patients. This review aims to examine the clinical, laboratory, ultrasound, and scintigraphic parameters that can be used for thyroid nodule management. PMID:22948464

  9. Endoscopic ultrasound-guided fine needle core biopsy for the diagnosis of pancreatic malignant lesions: a systematic review and Meta-Analysis

    PubMed Central

    Yang, Yongtao; Li, Lianyong; Qu, Changmin; Liang, Shuwen; Zeng, Bolun; Luo, Zhiwen

    2016-01-01

    Endoscopic ultrasound-guided fine needle core biopsy (EUS-FNB) has been used as an effective method of diagnosing pancreatic malignant lesions. It has the advantage of providing well preserved tissue for histologic grading and subsequent molecular biological analysis. In order to estimate the diagnostic accuracy of EUS-FNB for pancreatic malignant lesions, studies assessing EUS-FNB to diagnose solid pancreatic masses were selected via Medline. Sixteen articles published between 2005 and 2015, covering 828 patients, met the inclusion criteria. The summary estimates for EUS-FNB differentiating malignant from benign solid pancreatic masses were: sensitivity 0.84 (95% confidence interval (CI), 0.82–0.87); specificity 0.98 (95% CI, 0.93–1.00); positive likelihood ratio 8.0 (95% CI 4.5–14.4); negative likelihood ratio 0.17 (95% CI 0.10–0.26); and DOR 64 (95% CI 30.4–134.8). The area under the sROC curve was 0.96. Subgroup analysis did not identify other factors that could substantially affect the diagnostic accuracy, such as the study design, location of study, number of centers, location of lesion, whether or not a cytopathologist was present, and so on. EUS-FNB is a reliable diagnostic tool for solid pancreatic masses and should be especially considered for pathology where histologic morphology is preferred for diagnosis. PMID:26960914

  10. Fine-needle aspiration biopsy of large-cell undifferentiated carcinoma of the salivary glands: presentation of two cases, literature review, and differential cytodiagnosis of high-grade salivary gland malignancies.

    PubMed

    Moore, J G; Bocklage, T

    1998-07-01

    Primary undifferentiated carcinoma of the salivary glands is a rare, high-grade neoplasm which accounts for a very small number (1-5.5%) of malignant salivary gland tumors. The large-cell variant (LCU) is less well-characterized than the small-cell form. We report on the fine-needle aspiration (FNA) biopsy findings of 2 cases of LCU, one arising in the parotid gland, and the other in a buccal mucosa accessory salivary gland. The 2 cases were similar in composition: isolated and loosely cohesive large cells with abundant cytoplasm, and variability pleomorphic nuclei with prominent nucleoli. One case also featured multinucleated tumor giant cells and macrophage polykaryons; the latter has not previously been described in FNA biopsies of LCU. There was no evidence of squamous, myoepithelial, or widespread mucinous differentiation by morphological, cytochemical, or immunohistochemical analyses (focal rare mucin production identified on special stains in one case). The differential diagnosis is lengthy and consists of other high-grade primary salivary gland malignancies as well as metastatic lesions, including melanoma. The pattern of immunohistochemical reactivity (positive keratin, negative S-100, and HMB-45 antigens), and lack of conspicuous mucin production of significant lymphoidinfiltrate, were useful in establishing the correct diagnosis.

  11. Fine-needle aspiration of a Xp11.2 translocation/TFE3 fusion renal cell carcinoma metastatic to the lung: report of a case and review of the literature.

    PubMed

    Schinstine, Malcolm; Filie, Armando C; Torres-Cabala, Carlos; Abati, Andrea; Linehan, W Marston; Merino, Maria

    2006-11-01

    A 57-yr-old woman presented to the National Cancer Institute (NCI) with a history of nephrectomy for a clear cell renal cell carcinoma (RCC), Fuhrman grade 3 of 4 diagnosed 1 yr prior to admission to the NCI. A CT scan done upon admission revealed multiple bilateral lung masses. A CT-guided fine-needle aspiration (FNA) of one of the lung masses revealed a cellular specimen composed primarily of follicular structures surrounding dense hyalinized central cores. The cells in the follicular structures displayed bland nuclei and had granular to vacuolated cytoplasm. Papillary structures were also appreciated. Immunocytochemical studies showed tumor cells that were strongly vimentin and TFE3 positive. Focal staining for AE1/AE3 and CD10 was observed, as was negative staining for EMA. A surgical biopsy specimen reflected the FNA findings and demonstrated a similar immunoprofile. These findings correspond to the recently described Xp11.2 translocation/TFE3 fusion renal cell carcinoma. To our knowledge, this is the first report describing the cytologic features of an Xp11.2 translocation/TFE3 fusion RCC. (C) 2006 Wiley-Liss, Inc.

  12. Real-time image-based B-mode ultrasound image simulation of needles using tensor-product interpolation.

    PubMed

    Zhu, Mengchen; Salcudean, Septimiu E

    2011-07-01

    In this paper, we propose an interpolation-based method for simulating rigid needles in B-mode ultrasound images in real time. We parameterize the needle B-mode image as a function of needle position and orientation. We collect needle images under various spatial configurations in a water-tank using a needle guidance robot. Then we use multidimensional tensor-product interpolation to simulate images of needles with arbitrary poses and positions using collected images. After further processing, the interpolated needle and seed images are superimposed on top of phantom or tissue image backgrounds. The similarity between the simulated and the real images is measured using a correlation metric. A comparison is also performed with in vivo images obtained during prostate brachytherapy. Our results, carried out for both the convex (transverse plane) and linear (sagittal/para-sagittal plane) arrays of a trans-rectal transducer indicate that our interpolation method produces good results while requiring modest computing resources. The needle simulation method we present can be extended to the simulation of ultrasound images of other wire-like objects. In particular, we have shown that the proposed approach can be used to simulate brachytherapy seeds.

  13. An ultrasound needle insertion guide in a porcine phantom model.

    PubMed

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  14. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  15. The Role of CD56 in Thyroid Fine Needle Aspiration Cytology: A Pilot Study Performed on Liquid Based Cytology

    PubMed Central

    Bizzarro, Tommaso; Martini, Maurizio; Marrocco, Carla; D’Amato, Donato; Traini, Emanuela; Lombardi, Celestino Pio; Pontecorvi, Alfredo; Fadda, Guido; Larocca, Luigi Maria; Rossi, Esther Diana

    2015-01-01

    Background Fine needle aspiration Cytology (FNAC) fulfills a reliable role in the evaluation of thyroid lesions. Although the majority of nodules are quite easily diagnosed as benign or malignant, 30% of them represent an indeterminate category whereby the application of ancillary techniques (i.e. immunocytochemistry-ICC and molecular testing) has been encouraged. The search for a specific immunomarker of malignancy sheds light on a huge number of ICC stains although none of them attempt to yield 100% conclusive results. Our aim was to define in a pilot study on thyroid FNAC whether CD56 might be a valid marker also in comparison with HBME-1 and Galectin-3. Materials and Methods Inasmuch as this is the largest pilot study using only liquid based cytology (LBC), we selected all the cases only in the categories of benign nodules (BN) and positive for malignancy (PM) for validation purposes. Eighty-five consecutive (including 50 PM and 35 BN) out of 950 thyroid FNACs had surgical follow-up. The ICC panel (HBME-1, Galectin-3 and CD56) was carried out on LBC and histology. Results All BNs and PMs were histological confirmed. CD56 was negative in 96% of the PM while 68.5% of the BNs showed cytoplasmic positivity for this marker, with an overall high sensitivity (96%) but lower specificity (69%). In specific, our 96% of the PMs did not show any follicular cell with CD56 expression. Different ICC combinations were evaluated showing that the panel made up of CD56 plus HBME-1 and Galectin-3 had the highest sensitivity (98%) and specificity (86%). Conclusions Our pilot study suggests that CD56 may be a good marker for ruling out PTC and its variants. The low specificity suggests that an immunopanel including also HBME-1 and Galectin-3 could obtain the highest diagnostic accuracy in thyroid lesions. Our results suggest that CD56 may be a feasible additional marker for identifying malignancies also in the FNs and SMs. PMID:26186733

  16. Three-Dimensional Ultrasound-Guided Real-Time Midline Epidural Needle Placement with Epiguide: A Prospective Feasibility Study.

    PubMed

    Beigi, Parmida; Malenfant, Paul; Rasoulian, Abtin; Rohling, Robert; Dube, Alison; Gunka, Vit

    2017-01-01

    Current 2-D ultrasound technology is unable to perform a midline neuraxial needle insertion under real-time ultrasound guidance using a standard needle and without an assistant. The aim of the work described here was to determine the feasibility of a new technology providing such capability, starting with a study evaluating the selected puncture site. A novel 3-D ultrasound imaging technique was designed using thick-slice rendering in conjunction with a custom needle guide (3DUS + Epiguide). A clinical feasibility study evaluated the ability of 3DUS + Epiguide to identify the epidural needle puncture site for a midline insertion in the lumbar spine. We hypothesized that (i) the puncture site identified by 3DUS + Epiguide was within a 5-mm radius from the site chosen by standard palpation, and (ii) the difference between the two puncture sites was not correlated to the patient characteristics age, weight, height, body mass index and gestational age. The mean (±standard deviation) distances between puncture sites determined by 3DUS + Epiguide and palpation were 3.1 (±1.7) mm and 2.8 (±1.3) mm, for the L2-3 and L3-4 interspaces of 20 patients, respectively. Distances were comparable to intra-observer variability, indicating the potential for a thick-slice rendering of 3-D ultrasound along the Epiguide trajectory to select the puncture site of a midline neuraxial needle insertion. The long-term potential benefits of this system include increased efficiency and use of anesthesia, and a reduction in the frequency and severity of the complications from incorrect needle insertions. Epidural success in the most difficult cases (e.g., the obese) will be the focus of future work. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Fine needle aspiration of toxoplasmic lymphadenitis in an intramammary lymph node. A case report.

    PubMed

    Shimizu, K; Ito, I; Sasaki, H; Takada, E; Sunagawa, M; Masawa, N

    2001-01-01

    Cytologic findings of toxoplasmic lymphadenitis (TL) have been only sporadically reported. Intramammary lymph node is an extremely rare site for TL. A 47-year-old, healthy, female presented with a breast tumor, which was aspirated. The cytomorphologic features were interpreted as suggestive of TL. Histopathology of the excisional biopsy specimen and subsequent serologic examination confirmed the diagnosis. We obtained several characteristic findings in aspiration of TL. Of these, epithelioid cell clusters and monocytoid cells were the most diagnostic.

  18. Ultrasound-guided needle EMG of the diaphragm: technique description and case report.

    PubMed

    Boon, Andrea J; Alsharif, Kais I; Harper, C Michel; Smith, Jay

    2008-12-01

    We describe an ultrasound (US)-guided technique for needle examination of the diaphragm and report a case in which the adjuvant use of diagnostic US in conjunction with electrophysiologic studies provided additional information regarding the motion of the diaphragm in a patient who was a potential candidate for phrenic nerve pacing. US imaging provides excellent direct and real-time visualization of soft tissue, anatomic landmarks, fascial planes, and neurovascular structures. It thereby enhances safety by avoiding accidental needle puncture of vital organs, and it also increases the diagnostic utility of the needle examination.

  19. Evaluation of usefulness of fine-needle aspiration cytology in the diagnosis of tumours of the accessory parotid gland: a preliminary analysis of a case series in Japan.

    PubMed

    Iguchi, Hiroyoshi; Wada, Tadashi; Matsushita, Naoki; Oishi, Masahiro; Teranishi, Yuichi; Yamane, Hideo

    2014-07-01

    The accuracy and sensitivity of fine-needle aspiration cytology (FNAC) in this analysis were not satisfactory, and the false-negative rate seemed to be higher than for parotid tumours. The possibility of low-grade malignancy should be considered in the surgical treatment of accessory parotid gland (APG) tumours, even if the preoperative results of FNAC suggest that the tumour is benign. Little is known about the usefulness of FNAC in the preoperative evaluation of APG tumours, probably due to the paucity of APG tumour cases. We examined the usefulness of FNAC in the detection of malignant APG tumours. We conducted a retrospective analysis of 3 cases from our hospital, along with 18 previously reported Japanese cases. We compared the preoperative FNAC results with postoperative histopathological diagnoses of APG tumours and evaluated the accuracy, sensitivity, specificity and false-negative rates of FNAC in detecting malignant APG tumours. There were four false-negative cases (19.0%), three of mucoepidermoid carcinomas and one of malignant lymphoma. One false-positive result was noted in the case of a myoepithelioma, which was cytologically diagnosed as suspected adenoid cystic carcinoma. The accuracy, sensitivity and specificity of FNAC in detecting malignant tumours were 76.2%, 60.0% and 90.9%, respectively.

  20. Aspiration and methylprednisolone injection to the cavity with IV cannula needle in the treatment of volar wrist ganglia: New technique

    PubMed Central

    Korkmaz, Murat; Ozturk, Hayati; Amanvermez Senarslan, Dilsad; Erdogan, Yalcin

    2013-01-01

    Objective: There are several types of treatment modalities for wrist ganglions. The aim of the study was to assess the effectiveness of cyst aspiration and methyl prednisolone acetate injection with double IV cannula rather than sharp pointed needle, as a new technique in the treatment of volar ganglia. Methodology: The study involves total of 19 patients who received treatment by aspiration and methyl prednisolone injection into the cavity. Two IV cannulas are pricked to the cystic cavity. Cyst fluid is drained by the distally placed IV cannula meanwhile injecting methyl prednisolone by proximally placed IV cannula. The patient records and follow-up reports are retrospectively investigated. The patient age, sex, site of the cyst, the treatment that was applied, adjacency to the artery and the nerves and recurrence are recorded. Mean follow up time was 2.1±0.5 years. Results: The study involved 19 patients that received aspiration treatment for volar ganglion cysts between January 2004 and December 2009. There were 12 (63.2%) female and 7 (36.8%) male subject with volar wrist ganglion cyst. The mean age of patients was 27.63±6.6 years. Fourteen (73.7%) patients of total had cysts close to the artery. We didn’t observe any complication related to methyl prednisolone injection and arterial ischemia. Recurrence was observed in three (15.8%) patients. Conclusion: This method has lower recurrence rate than other aspiration therapy with sharp pointed needle. We prefer to use IV cannula needle for cyst aspiration and steroid injection in treatment of volar ganglia before any surgical intervention. PMID:24353517

  1. The cytomorphologic spectrum of Wilms tumour on fine needle aspiration: a single institutional experience of 110 cases.

    PubMed

    Nayak, A; Iyer, V K; Agarwala, S

    2011-02-01

    To analyse the cytomorphologic spectrum of Wilms tumour (WT) on aspirates, the largest series reported to date. Adequate aspirates from paediatric renal tumours over a period of 17 years were reviewed and selected if subsequent excision showed WT or aspirates were diagnostic for WT and clinical/radiological evidence consistent with that diagnosis. Smears were re-examined for the proportion of components, degree of pleomorphism and mitosis. Of 110 aspirates, smears were triphasic in 44 (40.0%), biphasic (blastema and tubules) in 36 (32.7%) and monophasic (blastema alone) in 30 (27.3%). Stromal predominance was seen in 11 aspirates (10.0%) and five showed rhabdomyoblastic differentiation; all 11 were triphasic. Mean mitotic rate was 9.3/5000 cells (range 4-39/5000). Nuclear atypia not amounting to anaplasia and without atypical mitoses was seen in 15 (13.6%); these presented diagnostic problems. Two aspirates (1.8%) were considered anaplastic (unfavourable), both having atypical mitoses. Criteria similar to histology (i.e. 3-fold or more variation in nuclear size, marked hyperchromasia with bizarre nuclei and atypical mitoses in a biphasic or triphasic aspirate) helped in distinguishing anaplastic WT. Histopathological correlation in 67 cases showed good correlation of blastemal predominance, stromal predominance and anaplastic histology with the corresponding cytology. However, 9/27 (33.3%) triphasic tumours had only blastemal cells on corresponding aspiration because of sampling error. Cytokeratin was positive in 4 of 20 aspirates with blastema alone. Aspirates from WT were triphasic or biphasic in the majority (72.7%), permitting cytological diagnosis, which was improved by cytokeratin immunocytochemistry. Blastemal and stromal predominance on histology correlated well with cytology, but many triphasic tumours showed only blastema on aspiration. Anaplastic WT can be detected on aspirates using criteria similar to histology. © 2010 Blackwell Publishing Ltd.

  2. The rational use of fine needle aspiration biopsy (FNAB) in diagnosing thyroid nodules.

    PubMed

    Sidoti, M; Marino, G; Resmini, E; Augeri, C; Cappi, C; Cavallero, D; Lagasio, C; Ceppa, P; Minuto, F; Giusti, M

    2006-06-01

    Fine needle aspiration biopsy (FNAB) plays a crucial role in the diagnosis of thyroid nodules and enables the number of surgical operations to be reduced. Theoretically, FNAB should be carried out on all nodules, though currently only those displaying certain characteristics are biopsied. Indeed, to perform FNAB on all nodules may be regarded as an excess of zeal. Therefore, it seems advisable that the endocrinologist should be able to confirm on the spot the necessity and utility of FNAB. We evaluated on a sample of 263 consecutive requests (209 female, 57 male; age 56.7+/-13.7 years) for FNAB in 2004: 1) the appropriateness of the investigation, 2) expected efficacy, 3) practical efficacy, 4) efficiency. FNAB was performed under echo-guidance in accordance with the standard technique. In 50%, 36%, 6%, 3%, 2% and 1% of cases, the echographic diagnosis was of MNG, UNG, pseudo-nodular lesion in ATD, lymph-node, neck cyst, suspected parathyroid lesion and tumefaction of the salivary glands, respectively. A pre-FNAB clinical risk score was assigned to each case on the basis of clinical and echographic data, with a maximum possible score of 11. The results of FNAB were subdivided into 5 categories according to the criteria of the BTA (Thy1-Thy5). After FNAB, a decisional category was assigned, ranging from ''observation'' to ''surgery''; this was subsequently (7-18 months) compared with the management strategy adopted by the attending physician. Information was gathered by means of telephone enquiry. 1) Appropriateness: on the basis of clinical and echographic findings, FNAB was not judged appropriate in 24% of cases because of either the lack of confirmation of a significant target (34%) or a low pre-FNAB risk score (range 0-2) (66%). The decisional category was ''observation'' in 87% of cases and ''further investigation'' in 13%. 2) Expected efficacy: FNAB was performed in 76% of cases. The biopsies (3%) performed on swollen lymph-nodes and extra-thyroid neck

  3. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer.

    PubMed

    Konge, L; Vilmann, P; Clementsen, P; Annema, J T; Ringsted, C

    2012-10-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliability and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC. A total of 30 patients with proven or suspected NSCLC underwent EUS - FNA for mediastinal staging by three trainees and three experienced physicians. Their performances were assessed prospectively by three experts in EUS under direct observation and again 2 months later in a blinded fashion using digital video-recordings. Based on the assessments, intra-rater reliability, inter-rater reliability, and construct validity were explored. The intra-rater reliability was good (Cronbach's α = 0.80), but comparison of results based on direct observations and blinded video-recordings indicated a significant bias favoring consultants (P = 0.022). Inter-rater reliability was very good (Cronbach's α = 0.93). However, one rater assessing five procedures or two raters each assessing four procedures were necessary to secure a generalizability coefficient of 0.80. The assessment tool demonstrated construct validity by discriminating between trainees and experienced physicians (P = 0.034). Competency in mediastinal staging of NSCLC using EUS and EUS - FNA can be assessed in a reliable and valid way using the EUSAT assessment tool. Measuring and defining competency and training requirements could improve EUS quality and benefit patient care. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Thoracic ultrasound-assisted selection for pleural biopsy with Abrams needle.

    PubMed

    Botana-Rial, Maribel; Leiro-Fernández, Virginia; Represas-Represas, Cristina; González-Piñeiro, Ana; Tilve-Gómez, Amara; Fernández-Villar, Alberto

    2013-11-01

    Closed pleural biopsy (CPB) in patients with malignant pleural effusion is less sensitive than cytology. Ultrasound-assisted CPB allows biopsies to be performed in the lower thoracic parietal pleura, where secondary spread from pleural metastases is initially more likely to be found. We analyzed whether choosing the point of entry for CPB with thoracic ultrasound assistance influences the diagnostic yield in malignant pleural effusion. This prospective study included patients who underwent CPB performed by an experienced pulmonologist in 2008-2010 (group A) and thoracic ultrasound was used to select the biopsy site. The results were compared with a historical series of CPB performed by the same pulmonologist without the assistance of thoracic ultrasound (group B). An Abrams needle was used in all cases. We analyzed the obtaining of pleural tissue and the diagnostic yield. We included 114 CPBs from group A (23% tuberculous pleural effusion, 27% malignant pleural effusion) and 67 CPBs from group B (24% tuberculous pleural effusion, 30% malignant pleural effusion) (P = .70). Pleural tissue was obtained in 96.5% of the group A CPBs and 89.6% of the group B CPBs (P = .05). The diagnostic yields of CPB for tuberculous pleural effusion and malignant pleural effusion in group A were 89.5% and 77.4%, respectively, and 91.7% and 60%, respectively, in group B (P = .80 for tuberculous pleural effusion, and P = .18 for malignant pleural effusion). Selecting the point of entry for CPB using thoracic ultrasound increases the likelihood of obtaining pleural tissue and the diagnostic yield, but without statistical significance. We recommend ultrasound-assisted CPB to investigate pleural effusion, since the diagnostic yield of a pleural biopsy with an Abrams needle increased by > 17% in subjects with malignant pleural effusion.

  5. Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.

    PubMed

    Masood, Shahla; Rosa, Marilin; Kraemer, Dale F; Smotherman, Carmen; Mohammadi, Amir

    2015-08-01

    Proven as a time challenged and cost-effective sampling procedure, the use of FNAB has still remained controversial among the scientific community. Currently, other minimally invasive sampling procedures such as ultrasound guided fine needle aspiration biopsy (US-FNAB) and image guided core needle biopsy (IG-CNB) have become the preferred sampling procedures for evaluation of breast lesions. However, changes in the medical economy and the current growing emphasis on cost containment in the era of the Affordable Care Act make it necessary to stimulate a renewed interest in the use of FNAB as the initial diagnostic sampling procedure. This study was designed to define the changing trend in the practice of tissue sampling during the last several years, and to assess the comparative effectiveness and appropriateness of the procedure of choice for breast cancer diagnosis. After Institutional Review Board (IRB) approval, the computer database of the Pathology Department, University of Florida, College of Medicine-Jacksonville at UF Health was retrospectively searched to identify all breast biopsy pathology reports issued during the period of January 2004 to December 2011. The inclusion criteria were all women that underwent any of the following biopsy types: FNAB, US-FNAB, IG-CNB, and surgical biopsy (SB). Diagnostic procedures were identified using current procedural terminology (CPT) codes recorded on claims from the UF Health Jacksonville patient accounting application files. The data obtained was used to determine which technique has the best cost-effectiveness in the diagnosis of breast cancer. The outcome variable for this project was a positive breast cancer diagnosis resulting from these methodologies. The predictor variable was the biopsy type used for sampling. The rate of cancer detection for each procedure was also determined. Among the four groups of procedures compared, the lower cost was attributed to FNAB, followed by US-FNAB, and SB. IG-CNB was the most

  6. Acupuncture sensation during ultrasound guided acupuncture needling

    PubMed Central

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  7. Tubercular thyroid abscess

    PubMed Central

    Kumar, Awanish; Pahwa, Harvinder Singh; Srivastava, Rohit; Khan, Khursheed Alam

    2013-01-01

    We encountered a patient who presented with neck swelling, difficulty in swallowing, voice change along with systemic features such as evening rise of temperature, chronic cough and weight loss. Ultrasonography of the thyroid gland revealed two cystic swellings. An ultrasound guided fine needle aspiration cytology was suggestive of tubercular abscess. The patient responded well to antigravity aspiration of the swellings and antitubercular treatment. PMID:23814203

  8. Use of Fine Needle Aspirate from Peripheral Nerves of Pure-neural Leprosy for Cytology and Polymerase Chain Reaction to Confirm the Diagnosis: A Follow-up Study of 4 Years.

    PubMed

    De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip

    2017-01-01

    Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective

  9. A Novel Method of Diagnosing Aberrant Pancreas: Needle-based Confocal Laser Endomicroscopy.

    PubMed

    Yasuda, Muneji; Hara, Kazuo; Kurita, Yusuke; Tanaka, Hiroki; Obata, Masahiro; Kuraoka, Naosuke; Matsumoto, Shimpei; Ito, Ayako; Iwaya, Hiromichi; Toriyama, Kazuhiro; Okuno, Nozomi; Kuwahara, Takamichi; Hijioka, Susumu; Mizuno, Nobumasa; Onishi, Sachiyo; Hirayama, Yutaka; Ishihara, Makoto; Tanaka, Tsutomu; Tajika, Masahiro; Niwa, Yasumasa

    2018-05-18

    Aberrant pancreas is defined as pancreatic tissue present outside of the pancreas and is often found incidentally during esophagogastroduodenoscopy. Obtaining sufficient tissue to differentiate aberrant pancreas from other subepithelial lesions is sometimes difficult. Due to the lack of a definitive diagnosis, patients often undergo unnecessary surgery. We herein report the first case of aberrant pancreas in which the concomitant use of needle-based probe confocal laser endomicroscopy and fine-needle aspiration supported the final diagnosis. Needle-based probe confocal laser endomicroscopy provides a real-time in vivo histopathology evaluation and may be a feasible means of diagnosing aberrant pancreas.

  10. Utility of conventional transbronchial needle aspiration with rapid on-site evaluation (c-TBNA-ROSE) at a tertiary care center with endobronchial ultrasound (EBUS) facility

    PubMed Central

    Madan, Neha Kawatra; Madan, Karan; Jain, Deepali; Walia, Ritika; Mohan, Anant; Hadda, Vijay; Mathur, Sandeep; Iyer, Venkateswaran K; Khilnani, Gopi C; Guleria, Randeep

    2016-01-01

    Background: Conventional transbronchial needle aspiration (c-TBNA) is an underutilized bronchoscopic modality. Endobronchial ultrasound (EBUS) guided-TBNA though efficacious is an expensive modality, facilities of which are available at only limited centers. c-TBNA is cost-effective and has potential for wide utilization especially in resource-limited settings. Rapid on-site evaluation (ROSE) improves the yield of c-TBNA. Materials and Methods: A retrospective review of the bronchoscopy records (May 2012 to July 2014) was performed. The patients who underwent c-TBNA with ROSE were included in the study and their clinical details were extracted. Convex probe EBUS-TBNA was being regularly performed during the study period by the operators performing c-TBNA. Results: c-TBNA with ROSE was performed in 41 patients with mean age of 42.4 (16.2) years. The most frequently sampled node stations (>90% patients) were the subcarinal and lower right paratracheal. Representative samples could be obtained in 33 out of the 41 patients (80.4%). c-TBNA was diagnostic in 32 [tuberculosis (TB)-8, sarcoidosis-9, and malignancy-15] patients out of the 41 patients. The overall diagnostic yield (sensitivity) of c-TBNA with ROSE was 78%. Mean procedure duration was 18.4 (3.1) min and there were no procedural complications. Conclusion: c-TBNA with ROSE is a safe, efficacious, and cost-effective bronchoscopic modality. When it was performed by operators routinely performing EBUS-TBNA, diagnostic yields similar to that of EBUS-TBNA can be obtained. Even at the centers where EBUS facilities are available, c-TBNA should be routinely performed. PMID:27011437

  11. Ultrasound guided aspiration of hydrosalpinx fluid versus salpingectomy in the management of patients with ultrasound visible hydrosalpinx undergoing IVF-ET: a randomized controlled trial.

    PubMed

    Fouda, Usama M; Sayed, Ahmed M; Abdelmoty, Hatem I; Elsetohy, Khaled A

    2015-01-01

    The aim of this study was to compare the efficacy of ultrasound guided aspiration of hydrosalpinx fluid at the time of oocyte retrieval with salpingectomy in the management of patients with ultrasound visible hydrosalpinx undergoing IVF-ET. One hundred and sixty patients with ultrasound visible hydrosalpinx were randomized into salpingectomy group and aspiration group using computer generated randomization list and sequentially numbered sealed envelopes containing allocation information written on a card. The clinical pregnancy rate per started cycle and the implantation rate were non- significantly higher in the salpingectomy group compared with the aspiration group [40% vs. 27.5% (p value = 0.132) and 18.95% vs. 12.82% (p value =0.124), respectively]. In the aspiration group, 34.21% of patients had rapid re-accumulation of the hydrosalpinx fluid (i.e. within first two weeks after embryo transfer). Whereas, the clinical pregnancy rate per transfer cycle and the implantation rate were significantly higher in salpingectomy group compared with the subgroup of patients with rapid re-accumulation of hydrosalpinx fluid [42.67% vs. 19.23% (p value = 0.036) and 18.95% vs. 7.58% (p value = 0.032), respectively], no significant differences were detected between the salpingectomy group and the subgroup of patients with no re-accumulation of hydrosalpinx fluid (42.67% vs. 34% (p value = 0.356) and 18.95% vs. 15.5% (p value = 0.457), respectively). The small sample size could be the cause of failure of detecting significant increase in implantation and pregnancy rates in salpingectomy group compared with aspiration group. Further larger randomized controlled trials are needed to determine whether salpingectomy is more effective than aspiration of hydrosalpinx fluid or not. Moreover, the data presented in this study suggested that rapid re-accumulation of hydrosalpinx fluid is an obstacle against successful implantation and the cause of lower success rate

  12. Estimating needle tip deflection in biological tissue from a single transverse ultrasound image: application to brachytherapy.

    PubMed

    Rossa, Carlos; Sloboda, Ron; Usmani, Nawaid; Tavakoli, Mahdi

    2016-07-01

    This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by virtual helical springs whose stiffness coefficient is found using a pattern search algorithm that only requires the force applied at the needle tip during insertion and the needle deflection measured at an arbitrary insertion depth. Needle tip deflections can then be predicted for different insertion depths. Verification of the proposed method in synthetic and biological tissue shows a deflection estimation error of [Formula: see text]2 mm for images acquired at 35 % or more of the maximum insertion depth, and decreases to 1 mm for images acquired closer to the final insertion depth. We also demonstrate the utility of the model for prostate brachytherapy, where in vivo needle deflection measurements obtained during early stages of insertion are used to predict the needle deflection further along the insertion process. The method can predict needle deflection based on the observation of deflection at a single point. The ultrasound probe can be maintained at the same position during insertion of the needle, which avoids complications of tissue deformation caused by the motion of the ultrasound probe.

  13. Automatic needle segmentation in 3D ultrasound images using 3D improved Hough transform

    NASA Astrophysics Data System (ADS)

    Zhou, Hua; Qiu, Wu; Ding, Mingyue; Zhang, Songgen

    2008-03-01

    3D ultrasound (US) is a new technology that can be used for a variety of diagnostic applications, such as obstetrical, vascular, and urological imaging, and has been explored greatly potential in the applications of image-guided surgery and therapy. Uterine adenoma and uterine bleeding are the two most prevalent diseases in Chinese woman, and a minimally invasive ablation system using a needle-like RF button electrode is widely used to destroy tumor cells or stop bleeding. To avoid accidents or death of the patient by inaccurate localizations of the electrode and the tumor position during treatment, 3D US guidance system was developed. In this paper, a new automated technique, the 3D Improved Hough Transform (3DIHT) algorithm, which is potentially fast, accurate, and robust to provide needle segmentation in 3D US image for use of 3D US imaging guidance, was presented. Based on the coarse-fine search strategy and a four parameter representation of lines in 3D space, 3DIHT algorithm can segment needles quickly, accurately and robustly. The technique was evaluated using the 3D US images acquired by scanning a water phantom. The segmentation position deviation of the line was less than 2mm and angular deviation was much less than 2°. The average computational time measured on a Pentium IV 2.80GHz PC computer with a 381×381×250 image was less than 2s.

  14. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    PubMed

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  15. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    PubMed

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions < 10 mm (7.2%) (P < .01) but without statistically significant differences among the 3 gauges (P > .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017

  16. Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images

    PubMed Central

    Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600

  17. Characterization of tissue-simulating phantom materials for ultrasound-guided needle procedures

    NASA Astrophysics Data System (ADS)

    Buchanan, Susan; Moore, John; Lammers, Deanna; Baxter, John; Peters, Terry

    2012-02-01

    Needle biopsies are standard protocols that are commonly performed under ultrasound (US) guidance or computed tomography (CT)1. Vascular access such as central line insertions, and many spinal needle therapies also rely on US guidance. Phantoms for these procedures are crucial as both training tools for clinicians and research tools for developing new guidance systems. Realistic imaging properties and material longevity are critical qualities for needle guidance phantoms. However, current commercially available phantoms for use with US guidance have many limitations, the most detrimental of which include harsh needle tracks obfuscating US images and a membrane comparable to human skin that does not allow seepage of inner media. To overcome these difficulties, we tested a variety of readily available media and membranes to evaluate optimal materials to fit our current needs. It was concluded that liquid hand soap was the best medium, as it instantly left no needle tracks, had an acceptable depth of US penetration and portrayed realistic imaging conditions, while because of its low leakage, low cost, acceptable durability and transparency, the optimal membrane was 10 gauge vinyl.

  18. The role of endobronchial ultrasound versus mediastinoscopy for non-small cell lung cancer.

    PubMed

    Czarnecka-Kujawa, Katarzyna; Yasufuku, Kazuhiro

    2017-03-01

    This review provides an update on the current role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and mediastinoscopy (Med) in assessment of patients with non-small cell lung cancer (NSCLC). Invasive mediastinal lymph node (LN) staging is the major application for both of these techniques. Up until recently, Med was the gold standard for invasive mediastinal LN staging in NSCLC. However, EBUS-TBNA has shown to be equivalent, and in some studies better than Med for invasive staging of lung cancer. EBUS-TBNA offers access to N1 LNs and development of the thin convex probe EBUS (TCP-EBUS) will expand EBUS-TBNA access from the paratracheal region and central airways to more distal parabronchial regions allowing for more extensive N1 LN assessment and sampling more distal lung tumors. EBUS-TBNA is more cost-effective than Med and it is currently recommended as the test of first choice for invasive mediastinal LN staging in lung cancer. Confirmatory Med should be performed selectively in patients with high pretest probability of metastatic disease. Addition of esophageal ultrasound fine needle aspiration (EUS-FNA) may increase diagnostic yield of EBUS-TBNA mediastinal staging. Both Med and EBUS-TBNA can be used in primary lung cancer diagnosis, restaging of the mediastinum following neoadjuvant therapy and in diagnosis of lung cancer recurrence. In the future, a combination of EBUS-TBNA with or without EUS-FNA and Med is most likely going to provide the most optimal invasive assessment of the mediastinum in patients with lung cancer. The decision on test choice and sequence should be made on a case-by-case basis and factoring in local resources and expertise.

  19. Impact of Rapid On-Site Cytological Evaluation (ROSE) on the Diagnostic Yield of Transbronchial Needle Aspiration During Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    PubMed

    Sehgal, Inderpaul Singh; Dhooria, Sahajal; Aggarwal, Ashutosh Nath; Agarwal, Ritesh

    2018-04-01

    Whether the use of rapid on-site cytologic evaluation (ROSE) increases the diagnostic yield of transbronchial needle aspiration (TBNA) remains unclear. This article is a systematic review of studies describing the utility of ROSE in subjects undergoing TBNA. The study included a systematic review of the PubMed, Embase, and Scopus databases for randomized controlled trials investigating the diagnostic yield of conventional transbronchial needle aspiration (c-TBNA) or endobronchial ultrasound (EBUS)-TBNA, with or without ROSE, in subjects with mediastinal lymphadenopathy. Five studies (618 subjects; two EBUS-TBNA, two c-TBNA, and one both) were identified. Overall, the studies were of good quality. The pooled risk difference (95% CI) of the diagnostic yield of EBUS-TBNA and c-TBNA was 0.04 (-0.01 to 0.09) and 0.12 (-0.08 to 0.33), respectively, suggesting no added benefit with ROSE. The use of ROSE during EBUS-TBNA (but not c-TBNA) resulted in significantly fewer needle passes (mean difference [95% CI], -1.1 [-2.2 to -0.005]; P < .001). There was no difference in the procedure time during EBUS-TBNA. The complication rate was significantly lower (OR [95% CI], 0.26 [0.10 to 0.71]; P = .009) when ROSE was used during c-TBNA due to fewer additional procedures required to make a diagnosis. There was evidence of heterogeneity in the studies involving c-TBNA but not EBUS-TBNA. There was no publication bias. The use of ROSE neither improved the diagnostic yield nor reduced the procedure time during TBNA. However, the use of ROSE was associated with fewer number of needle passes during EBUS-TBNA and overall lower requirement for additional bronchoscopy procedures during TBNA to make a final diagnosis. PROSPERO; No.: CRD42017058937; URL: www.crd.york.ac.uk/prospero/. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  20. Immunocytochemical characterization of lung tumors in fine-needle aspiration. The use of cytokeratin monoclonal antibodies for the differential diagnosis of squamous cell carcinoma and adenocarcinoma.

    PubMed

    Bruderman, I; Cohen, R; Leitner, O; Ronah, R; Guber, A; Griffel, B; Geiger, B

    1990-10-15

    In the current study, immunocytochemical typing of intermediate filaments was used for a differential diagnosis of human lung tumors from transthoracic fine-needle aspiration biopsies (TFNAB). The authors have compared the cytologic diagnosis of 53 lung cancer cases with the immunofluorescence patterns obtained using a panel of monoclonal antibodies, five of which (KG 8.13, KM 4.62, Ks B.17, KS 8.12, KK 8.60) react with specific cytokeratin polypeptides and one with vimentin (VIM 13.2). Only in six of 23 samples cytologically diagnosed as squamous cell carcinoma did the immunocytochemical typing of cytokeratins (ICTC) confirm the cytologic diagnosis. In seven cases some of the tumor cells stained positively with antibody Ks B.17 specific for simple epithelial keratin (No: 18), suggesting the presence of some cells of glandular origin. In ten additional cases the ICTC was in conflict with the cytologic diagnosis of squamous cell carcinoma (i.e., antibodies Ks 8.12 and KK 8.60 were negative, and antibody Ks B.17, positive) supporting a diagnosis of adenocarcinoma. In 14 of 18 cases cytologically diagnosed as adenocarcinoma, the ICTC confirmed the diagnosis whereas in four cases additional presence of some squamous cells was noticed. The ICTC labeling of cases cytologically diagnosed as undifferentiated and large cell carcinomas was similar to that of the group of adenocarcinomas. Thus, the application of cytokeratin typing for TFNAB samples seems to provide a vital complementation to routine cytologic study, especially for cases cytologically diagnosed as squamous carcinoma.

  1. 360-degree 3D transvaginal ultrasound system for high-dose-rate interstitial gynaecological brachytherapy needle guidance

    NASA Astrophysics Data System (ADS)

    Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron

    2017-03-01

    Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.

  2. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    PubMed

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. Molecular Testing for miRNA, mRNA, and DNA on Fine-Needle Aspiration Improves the Preoperative Diagnosis of Thyroid Nodules With Indeterminate Cytology.

    PubMed

    Labourier, Emmanuel; Shifrin, Alexander; Busseniers, Anne E; Lupo, Mark A; Manganelli, Monique L; Andruss, Bernard; Wylie, Dennis; Beaudenon-Huibregtse, Sylvie

    2015-07-01

    Molecular testing for oncogenic mutations or gene expression in fine-needle aspirations (FNAs) from thyroid nodules with indeterminate cytology identifies a subset of benign or malignant lesions with high predictive value. This study aimed to evaluate a novel diagnostic algorithm combining mutation detection and miRNA expression to improve the diagnostic yield of molecular cytology. Surgical specimens and preoperative FNAs (n = 638) were tested for 17 validated gene alterations using the miRInform Thyroid test and with a 10-miRNA gene expression classifier generating positive (malignant) or negative (benign) results. Cross-sectional sampling of thyroid nodules with atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) or follicular neoplasm/suspicious for a follicular neoplasm (FN/SFN) cytology (n = 109) was conducted at 12 endocrinology centers across the United States. Qualitative molecular results were compared with surgical histopathology to determine diagnostic performance and model clinical effect. Mutations were detected in 69% of nodules with malignant outcome. Among mutation-negative specimens, miRNA testing correctly identified 64% of malignant cases and 98% of benign cases. The diagnostic sensitivity and specificity of the combined algorithm was 89% (95% confidence interval [CI], 73-97%) and 85% (95% CI, 75-92%), respectively. At 32% cancer prevalence, 61% of the molecular results were benign with a negative predictive value of 94% (95% CI, 85-98%). Independently of variations in cancer prevalence, the test increased the yield of true benign results by 65% relative to mRNA-based gene expression classification and decreased the rate of avoidable diagnostic surgeries by 69%. Multiplatform testing for DNA, mRNA, and miRNA can accurately classify benign and malignant thyroid nodules, increase the diagnostic yield of molecular cytology, and further improve the preoperative risk-based management of benign nodules with

  4. SU-E-J-81: Beveled Needle Tip Detection Error in Ultrasound-Guided Prostate Brachytherapy.

    PubMed

    Leu, S; Ruiz, B; Podder, T

    2012-06-01

    To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Covington, GA) were used. The TRUS was set at 6.5MHz in water phantom at 40°C and measurements were taken with 50% and 100% TRUS gains. Needles were oriented with bevel-tip facing up (0-degree) and inserted through template grid-holes. Reference needle depths were measured when needle tip image intensity was bright enough for potentially consistent readings. High-resolution digital vernier caliper was used to measure needle depth. Needle bevel-tip orientation was then changed to bevel down (by rotating 180-degree) and needle depth was adjusted by retracting so that the needle-tip image intensity appeared similar to when the needle bevel-tip was at 0-degree orientation. Clinically relevant locations were considered for needle placement on the template grids (1st row to 9th row, and 'a-f' columns). For 50% TRUS gain, bevel tip detection errors/differences were 0.69±0.30mm (1st row) to 3.23±0.22mm (9th row) and 0.78±0.71mm (1st row) to 4.14±0.56mm (9th row) in columns 'a' and 'D', respectively. The corresponding errors for 100% TRUS gain were 0.57±0.25mm to 5.24±0.36mm and 0.84±0.30mm to 4.2±0.20mm in columns 'a' and 'D', respectively. These errors/differences varied linearly for grid-hole locations on the rows and columns in between, smaller to large depending on distance from the TRUS probe. Observed no effect of gains (50% vs. 100%) along 'D' column, which was directly above the TRUS probe. Experiment results revealed that the beveled needle tip orientation could significantly impact the detection accuracy of the needle tips, based on which the seeds might be delivered. These errors may lead to considerable dosimetric deviations in prostate brachytherapy seed

  5. Use of Fine Needle Aspirate from Peripheral Nerves of Pure-neural Leprosy for Cytology and Polymerase Chain Reaction to Confirm the Diagnosis: A Follow-up Study of 4 Years

    PubMed Central

    De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip

    2017-01-01

    Background: Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. Aim: This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. Materials and Methods: All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. Results: A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. Conclusion: The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily

  6. Combined cumulative sum (CUSUM) and chronological environmental analysis as a tool to improve the learning environment for linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) trainees: a pilot study.

    PubMed

    Norisue, Yasuhiro; Tokuda, Yasuharu; Juarez, Mayrol; Uchimido, Ryo; Fujitani, Shigeki; Stoeckel, David A

    2017-02-07

    Cumulative sum (CUSUM) analysis can be used to continuously monitor the performance of an individual or process and detect deviations from a preset or standard level of achievement. However, no previous study has evaluated the utility of CUSUM analysis in facilitating timely environmental assessment and interventions to improve performance of linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aim of this study was to evaluate the usefulness of combined CUSUM and chronological environmental analysis as a tool to improve the learning environment for EBUS-TBNA trainees. This study was an observational chart review. To determine if performance was acceptable, CUSUM analysis was used to track procedural outcomes of trainees in EBUS-TBNA. To investigate chronological changes in the learning environment, multivariate logistic regression analysis was used to compare several indices before and after time points when significant changes occurred in proficiency. Presence of an additional attending bronchoscopist was inversely associated with nonproficiency (odds ratio, 0.117; 95% confidence interval, 0-0.749; P = 0.019). Other factors, including presence of an on-site cytopathologist and dose of sedatives used, were not significantly associated with duration of nonproficiency. Combined CUSUM and chronological environmental analysis may be useful in hastening interventions that improve performance of EBUS-TBNA.

  7. Can We Confidently Diagnose Pilomatricoma with Fine Needle Aspiration Cytology?

    PubMed Central

    WONG, Yin-Ping; MASIR, Noraidah; SHARIFAH, Noor Akmal

    2015-01-01

    Pilomatricomas can be confidently diagnosed cytologically due to their characteristic cytomorphological features. However, these lesions are rarely encountered by cytopathologists and thus pose a diagnostic dilemma to even experienced individuals, especially when the lesions are focally sampled. We describe two cases of histologically confirmed pilomatricoma. The first case is of a 13-year-old boy with posterior cervical ‘lymphadenopathy’, and the second one is of a 12-year-old girl with a lower cheek swelling. Both aspirates comprised predominantly atypical basal-like cells, with prominent nucleoli. ‘Ghost cells’ were readily identified by cell block in case two, but cell block in case one yielded no diagnostic material. In case two, pilomatricoma was accurately diagnosed pre-operatively. A cytological suspicion of a neoplastic process was raised in case one. Despite being diagnostically challenging, pilomatricoma can be diagnosed with careful observation of two unique cytological features of the lesions: (1) pathognomonic ‘ghost cells’ and (2) irregular, saw-toothed, loosely cohesive basaloid cells, with prominent nucleoli. The role of thorough sampling of the lesion, with multiple passes of various sites, cannot be overemphasized. PMID:25892955

  8. Direct comparison of the diagnostic yield of ultrasound-assisted Abrams and Tru-Cut needle biopsies for pleural tuberculosis.

    PubMed

    Koegelenberg, Coenraad Frederik N; Bolliger, Christoph Thomas; Theron, Johan; Walzl, Gerhard; Wright, Colleen Anne; Louw, Mercia; Diacon, Andreas Henri

    2010-10-01

    Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles. This prospective study compared ultrasound-assisted Abrams and Tru-Cut needle biopsies with regard to their diagnostic yield for pleural tuberculosis. 89 patients (54 men) of mean ± SD age 38.7 ± 16.7 years with pleural effusions and a clinical suspicion of tuberculosis were enrolled in the study. Transthoracic ultrasound was performed on all patients, who were then randomly assigned to undergo ≥ 4 Abrams needle biopsies followed by ≥ 4 Tru-Cut needle biopsies or vice versa. Medical thoracoscopy was performed on cases with non-diagnostic closed biopsies. Histological and/or microbiological proof of tuberculosis on any pleural specimen was considered the gold standard for pleural tuberculosis. Pleural tuberculosis was diagnosed in 66 patients, alternative diagnoses were established in 20 patients and 3 remained undiagnosed. Pleural biopsy specimens obtained with Abrams needles contained pleural tissue in 81 patients (91.0%) and were diagnostic for tuberculosis in 54 patients (sensitivity 81.8%), whereas Tru-Cut needle biopsy specimens only contained pleural tissue in 70 patients (78.7%, p=0.015) and were diagnostic in 43 patients (sensitivity 65.2%, p=0.022). Ultrasound-assisted pleural biopsies performed with an Abrams needle are more likely to contain pleura and have a significantly higher diagnostic sensitivity for pleural tuberculosis.

  9. NA cohort study of thyroid cancer and other thyroid diseases after the Chernobyl accident: cytohistopathologic correlation and accuracy of fine-needle aspiration biopsy in nodules detected during the first screening in Ukraine (1998-2000).

    PubMed

    Bozhok, Yuriy; Greenebaum, Ellen; Bogdanova, Tetyana I; McConnell, Robert J; Zelinskaya, Anna; Brenner, Alina V; Zurnadzhy, Lyudmyla Y; Zablotska, Lydia; Tronko, Mykola D; Hatch, Maureen

    2009-04-25

    The Ukrainian American Cohort Study was established to evaluate the risk of thyroid disorders in a group exposed as children and adolescents to 131I by the Chernobyl accident (arithmetic mean thyroid dose, 0.79 grays). Individuals are screened by palpation and ultrasound and are referred to surgery according to fine-needle aspiration biopsy (FNA). However, the accuracy of FNA cytology for detecting histopathologically confirmed malignancy after this level of internal exposure to radioiodines is unknown. During the first screening cycle (1998-2000), 13,243 individuals were examined, 356 individuals with thyroid nodules were referred for FNA, 288 individuals completed the procedure, 85 individuals were referred to surgery, 82 individuals underwent surgery, and preoperative cytology was available for review in 78 individuals. Cytologic interpretation for the nodule that resulted in surgical referral was correlated with final pathomorphology; discrepancies were reviewed retrospectively; and the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of FNA cytology were calculated. All 24 cytologic interpretations that were definite for papillary thyroid cancer (PTC) were confirmed histopathologically (PPV, 100%); and, of 11 cytologic interpretations that were suspicious for PTC, 10 were confirmed (PPV, 90.9%). Ten of 41 FNAs that were interpreted as either definite or suspect for follicular neoplasm were confirmed as malignant (PPV, 24.4%), including 2 follicular thyroid cancers and 8 PTCs (all but 1 of the follicular or mixed subtypes). Depending on whether a cytologic interpretation of follicular neoplasm was considered "positive" or "negative," the sensitivity was 100% and 77.3%, respectively; similarly, the respective specificity was 17.6% and 97.1%, the respective PPV was 61.1% and 97.1%, and the respective NPV was 100% and 76.7%. Among children and adolescents who were exposed to 131I after the Chernobyl accident and were

  10. Hormones, Women and Breast Cancer

    MedlinePlus

    ... sure that it is benign (not cancer). These tests can include • A mammogram • A breast ultrasound • A sample of cells from the lump (called a fine needle aspirate) • A sample of a piece of tissue from the lump (called a core biopsy) Possible Symptoms of Breast Cancer • A lump • ...

  11. Ultrasound guided needle localization and microsurgical exploration for incidental nonpalpable testicular tumors.

    PubMed

    Hopps, Carin V; Goldstein, Marc

    2002-09-01

    We describe a technique by which incidental, nonpalpable intratesticular tumors are excised using intraoperative ultrasonography and the operating microscope. Men with impalpable intratesticular tumors incidentally detected by ultrasonography underwent intraoperative ultrasound guided needle localization and microsurgical exploration of the mass. The testis was delivered through an inguinal incision and placed on ice to minimize warm ischemia. Two rubber shod vascular clamps were placed across the spermatic cord. The tumor was identified by ultrasound and localized with a 30 gauge needle, which was placed adjacent to the tumor. An operating microscope providing 6x to 25x magnification was used to excise the lesion with a 2 to 5 mm. margin. Tissue diagnosis was obtained by frozen section. Multiple random biopsies of the remaining parenchyma were done to confirm absent malignancy. Ultrasound showed incidental, nonpalpable testis tumors in 4 of the 65 men who underwent infertility evaluation and were entered into the microsurgical testis biopsy database between January 1995 and December 2001. All lesions were hypoechoic. Frozen section analysis of the lesions revealed 2 Leydig cell tumors, 1 mass with an inconclusive pathological diagnosis and 1 inflammatory mass. On permanent section the latter 2 lesions were seminoma. The seminomas were 1.6 and 0.9 cm. in the greatest diameter, and the Leydig cell tumors were 0.35 and 0.2 cm., respectively. Random biopsies were positive for seminoma and intratubular germ cell neoplasia in both testes with seminoma. These 2 patients subsequently opted to undergo radical orchiectomy. No residual tumor was detected in either radical orchiectomy specimen. Intraoperative ultrasound guided needle localization with microsurgical exploration is a safe and effective approach to even small impalpable testicular masses. This technique provides the opportunity to identify and remove benign and malignant lesions, and preserve the testis when the

  12. Immunocytochemistry for MUC4 and MUC16 is a useful adjunct in the diagnosis of pancreatic adenocarcinoma on fine-needle aspiration cytology.

    PubMed

    Horn, Adam; Chakraborty, Subhankar; Dey, Parama; Haridas, Dhanya; Souchek, Joshua; Batra, Surinder K; Lele, Subodh M

    2013-04-01

    Diagnoses rendered as atypical/suspicious for malignancy on fine-needle aspiration (FNA) of pancreatic mass lesions range from 2% to 29% in various studies. We have identified the expression of 3 genes, MUC4, MUC16, and NGAL that are highly upregulated in pancreatic adenocarcinoma. In this study, we analyzed the expression of these markers in FNA samples to determine whether they could improve sensitivity and specificity. To evaluate the utility of MUC4, MUC16, and NGAL in the evaluation of pancreatic FNA specimens. Records of pancreatic FNAs performed during 10 consecutive years were reviewed. Unstained sections from corresponding cell blocks were immunostained for MUC4, MUC16, and NGAL (polyclonal). Immunostaining was assessed using the H-score (range, 0-3). Any case with an H-score of >0.5 was considered positive. Cases were classified using cytomorphologic criteria as adenocarcinoma (31 of 64; 48.4%), benign (17 of 64; 26.6%), and atypical/suspicious (16 of 64; 25%). On follow-up, all cases (100%; 31 of 31) diagnosed as carcinoma on cytology were confirmed on biopsy/resection samples or by clinical follow-up (such as unresectable disease). Of the cases diagnosed as atypical/suspicious, 69% (11 of 16) were found to be positive for adenocarcinoma and 31% (5 of 16) were benign on subsequent follow-up. Overall sensitivity and specificity, respectively, for the various markers for the detection of pancreatic adenocarcinoma were as follows: MUC4 (74% and 100%), MUC16 (62.9% and 100%), and NGAL (61.3% and 58.8%). In cases that were atypical/suspicious on cytology, expression of MUC4 and MUC16 was 100% specific for carcinoma with sensitivities of 63.6% and 66.7%, respectively. Immunocytochemistry for MUC4 and MUC16 appears to be a useful adjunct in the classification of pancreatic FNA samples, especially in cases that are equivocal (atypical/suspicious) for adenocarcinoma on cytomorphologic assessment.

  13. Endoscopic Ultrasound-guided Specimen Collection and Evaluation Techniques Affect Diagnostic Accuracy.

    PubMed

    Bang, Ji Young; Navaneethan, Udayakumar; Hasan, Muhammad K; Hawes, Robert; Varadarajulu, Shyam

    2018-03-11

    Outcomes of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) evaluation vary with technique, needles, and methods of specimen evaluation. We performed a direct comparison of diagnostic yields of EUS-FNA samples collected using different gauge needles (22- vs 25-gauge), with or without suction. We performed a randomized controlled study of 352 patients with suspected pancreatic masses, referred for EUS-FNA at a tertiary referral center. Patients were randomly assigned to 22-gauge needles with or without suction or 25-gauge needles with or without suction. Specimens were evaluated offsite by cell block and rapid onsite cytologic evaluation (ROSE). Final diagnoses were made based on histologic analyses or 12-month follow-up evaluations. The primary outcome was diagnostic adequacy of cell blocks. Secondary outcomes were operating characteristics of ROSE and EUS-FNA, number of passes required for accurate onsite diagnosis, and amount of blood in specimens. The final diagnoses were malignancy (81.5% of patients) and benign disease (17.0% of patients); 1.4% of patients were lost during follow up. Cell block, ROSE, and EUS-FNA led to diagnostic accuracies of 71.9%, 95.5%, and 96.6%, respectively. A 22-gauge needle with suction was associated with more passes for adequate onsite diagnosis (P = .003) and specimens contained more blood (P = .01). Diagnostic accuracy of specimens collected by transduodenal EUS-FNA was lower with 22-gauge needles with suction compared to other techniques (P = .004). In a randomized trial of patients undergoing EUS-FNA for pancreatic masses, samples collected with 22-gauge vs 25-gauge needles performed equally well for offsite specimen evaluation. Use of suction appears to increase number of passes needed and specimen bloodiness. Specimen collection techniques should be individualized based on method of evaluation. ClinicalTrials.gov no: NCT02424838. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  14. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  15. Cytology and direct HPV testing on Fine-Needle aspirates from cervical lymph node metastases of patients with Oropharyngeal Squamous Cell Carcinoma or occult primary.

    PubMed

    Rollo, Francesca; Dona', Maria Gabriella; Pellini, Raul; Pichi, Barbara; Marandino, Ferdinando; Covello, Renato; Benevolo, Maria

    2018-06-06

    Cervical lymph node Fine Needle Aspirates (FNAs) may represent the only specimens available for an initial characterization of patients with lymphadenopathy. Morphology and HPV-DNA presence were evaluated in FNAs collected from patients with oropharyngeal cancer (OPSCC) or cancer of unknown primary (CUP). FNA HPV results were compared with those of the respective formalin-fixed paraffin-embedded (FFPE) primary cancer. Liquid-based cytology was performed on FNAs collected in PreservCyt. HPV-DNA was analyzed by the INNO-LiPA HPV genotyping Extra II on both cytological and FFPE samples. The CINtec ® Histology Kit was used to assess p16 expression in cancer tissues. Forty-seven FNAs were collected from OPSCC and 16 from CUP patients. Cancer cells were found in 35/47 cases (74.5%), while 11 (23.4%) showed only necrosis, and 1 (2.1%) was negative for malignancy. HPV-DNA was detected in 30/47 FNAs (63.8%), mostly harboring HPV16 (90.0%). An excellent agreement was observed between the FNA and corresponding FFPE HPV status (raw agreement: 97.5%; Cohen K: 0.94). The HPV test result on the necrotic FNAs completely matched that of the respective primary cancer. FNA HPV testing correctly identified 26/27 HPV-driven OPSCCs (96.3%). HPV was detected in 9/16 FNAs (56.2%) from CUP patients. HPV status of metastatic cervical lymph node FNAs reflects that of the corresponding primary OPSCCs even when cell integrity in the FNA is not preserved and only necrotic debris are present. In patients with initial CUP, HPV-positivity on the FNA may guide the diagnostic workup and therapeutic management, since it suggests an oropharyngeal origin. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  16. Calcitonin assay in wash-out fluid after fine-needle aspiration biopsy in patients with a thyroid nodule and border-line value of the hormone.

    PubMed

    Massaro, F; Dolcino, M; Degrandi, R; Ferone, D; Mussap, M; Minuto, F; Giusti, M

    2009-04-01

    Assaying calcitonin (CT) in the wash-out fluid from fine-needle aspiration biopsies (CT-FNAB) could be useful in the diagnosis of medullary thyroid carcinoma (MTC). The aim of this study was to correlate serum CT with cytology and CT-FNAB. Twenty-seven subjects (age range 27-75 yr) were studied. FNAB was performed in a thyroid nodule (no.=16) or lymph-node (no.=1 previously operated on for MTC) or in the prevalent nodule of multinodular goiters (no.=10). CT-FNAB values obtained in 37 subjects with normal serum CT (<10 ng/l) who underwent FNAB for thyroid nodules served as a negative control. In these subjects, CTFNAB values were 8.2+/-6.4 ng/l (range 2-30 ng/l). In patients with a thyroid nodule under evaluation for MTC, serum CT and CT-FNAB values were 14.5+/-3.9 ng/l (range 10-24 ng/l) and 16.4+/-29.8 ng/l (range 2-144 ng/l), respectively. In 4 patients, CT-FNAB values were higher than the highest values found in our negative controls (30 ng/l), but cytology results were compatible with a benign thyroid lesion and pentagastrin testing was negative. In 3 cases with CT-FNAB <30 ng/l, cytology was indicative of an indeterminate or probably follicular malignant lesion and histology was negative for MTC. None of the other subjects in whom pentagastrin testing was conducted showed serum CT values >100 ng/l. Our data do not show any correlation between CT-FNAB and serum CT. In conclusion, borderline CT values in patients with thyroid nodules are not rare. Our experience suggests that CT-FNAB does not have the same importance as that reported in the literature for thyroglobulin and PTH assay in wash-out fluid after FNAB in malignant thyroid and hyperfunctioning parathyroid lesions.

  17. Segmentation of prostate biopsy needles in transrectal ultrasound images

    NASA Astrophysics Data System (ADS)

    Krefting, Dagmar; Haupt, Barbara; Tolxdorff, Thomas; Kempkensteffen, Carsten; Miller, Kurt

    2007-03-01

    Prostate cancer is the most common cancer in men. Tissue extraction at different locations (biopsy) is the gold-standard for diagnosis of prostate cancer. These biopsies are commonly guided by transrectal ultrasound imaging (TRUS). Exact location of the extracted tissue within the gland is desired for more specific diagnosis and provides better therapy planning. While the orientation and the position of the needle within clinical TRUS image are limited, the appearing length and visibility of the needle varies strongly. Marker lines are present and tissue inhomogeneities and deflection artefacts may appear. Simple intensity, gradient oder edge-detecting based segmentation methods fail. Therefore a multivariate statistical classificator is implemented. The independent feature model is built by supervised learning using a set of manually segmented needles. The feature space is spanned by common binary object features as size and eccentricity as well as imaging-system dependent features like distance and orientation relative to the marker line. The object extraction is done by multi-step binarization of the region of interest. The ROI is automatically determined at the beginning of the segmentation and marker lines are removed from the images. The segmentation itself is realized by scale-invariant classification using maximum likelihood estimation and Mahalanobis distance as discriminator. The technique presented here could be successfully applied in 94% of 1835 TRUS images from 30 tissue extractions. It provides a robust method for biopsy needle localization in clinical prostate biopsy TRUS images.

  18. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  19. [Percutaneous ultrasound-guided drainage in the surgical treatment of acute severe pancreatitis].

    PubMed

    Delattre, J-F; Levy Chazal, N; Lubrano, D; Flament, J-B

    2004-11-01

    To report results of percutaneous ultrasound-guided drainage, performed by a surgeon, in the treatment of complications of acute pancreatitis (AP), and to determine the role of this technique in the therapeutic armamentarium of severe AP. From 1986 to 2001, 59 patients were included in this retrospective study. All patients initially had severe necrotizing AP (mean Ranson score = 4.1 ; range : 2-7). Anatomical lesions included pancreatic abscess in 6 patients and necrosis in 53 (17 stage D and 36 stage E according to Balthazar's classification). Necrosis was infected in 42 and sterile in 11 respectively. Drainage was performed under ultrasound guidance and local anaesthesia using small-diameter drains (7-14 French). Drainage was performed on average 23 days after onset of AP. Infection was proven by fine-needle aspiration in 47 (80 %) patients (41 infected necrosis and 6 localized abscess). In one patient, culture of aspirated fluid was negative but necrosis was infected (one false negative). Culture of aspirated fluid was negative and necrosis was sterile in 11 patients. Nineteen (32%) patients healed without subsequent surgery: 7 (16%) in the infected necrosis group, 6(55%) in the sterile necrosis group, and 6 (100%) in the abscess group. Forty (68%) patients had subsequent necrosectomy including 8 (14%) who died. Twenty (34 %) digestive fistulas healed spontaneously, except one treated by diversion stomia. Of the 16 (27 %) pancreatic fistulas, 6 needed subsequent interventional treatment. In selected patients, percutaneous drainage can represent an alternative to surgery with a 14% mortality rate. The high rate of subsequent necrosectomy suggests that drains with larger diameter, possibly associated with continuous irrigation, should be used.

  20. Learning, techniques, and complications of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline.

    PubMed

    Polkowski, M; Larghi, A; Weynand, B; Boustière, C; Giovannini, M; Pujol, B; Dumonceau, J-M

    2012-02-01

    This article is the second of a two-part publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided Trucut biopsy. The first part (the Clinical Guideline) focused on the results obtained with EUS-guided sampling, and the role of this technique in patient management, and made recommendations on circumstances that warrant its use. The current Technical Guideline discusses issues related to learning, techniques, and complications of EUS-guided sampling, and to processing of specimens. Technical issues related to maximizing the diagnostic yield (e.g., rapid on-site cytopathological evaluation, needle diameter, microcore isolation for histopathological examination, and adequate number of needle passes) are discussed and recommendations are made for various settings, including solid and cystic pancreatic lesions, submucosal tumors, and lymph nodes. The target readership for the Clinical Guideline mostly includes gastroenterologists, oncologists, internists, and surgeons while the Technical Guideline should be most useful to endoscopists who perform EUS-guided sampling. A two-page executive summary of evidence statements and recommendations is provided. © Georg Thieme Verlag KG Stuttgart · New York.

  1. ECM1 and TMPRSS4 Are Diagnostic Markers of Malignant Thyroid Neoplasms and Improve the Accuracy of Fine Needle Aspiration Biopsy

    PubMed Central

    Kebebew, Electron; Peng, Miao; Reiff, Emily; Duh, Quan-Yang; Clark, Orlo H.; McMillan, Alex

    2005-01-01

    Objective: The objective of this study was to determine whether genes that regulate cellular invasion and metastasis are differentially expressed and could serve as diagnostic markers of malignant thyroid nodules. Summary and Background Data: Patients whose thyroid nodules have indeterminate or suspicious cytologic features on fine needle aspiration (FNA) biopsy require thyroidectomy because of a 20% to 30% risk of thyroid cancer. Cell invasion and metastasis is a hallmark of malignant phenotype; therefore, genes that regulate these processes might be differentially expressed and could serve as diagnostic markers of malignancy. Methods: Differentially expressed genes (2-fold higher or lower) in malignant versus benign thyroid neoplasms were identified by extracellular matrix and adhesion molecule cDNA array analysis and confirmed by real-time quantitative polymerase chain reaction (PCR). The area under the receiver operating characteristic (AUC) curve was calculated to determine diagnostic accuracy of gene expression level cutoffs established by logistic regression analysis. Results: By cDNA array analysis, ADAMTS8, ECM1, MMP8, PLAU, SELP, and TMPRSS4 were upregulated, and by quantitative PCR, ECM1, SELP, and TMPRSS4 mRNA expression was higher in malignant (n = 57) than in benign (n = 38) thyroid neoplasms (P< 0.002). ECM1 and TMPRSS4 mRNA expression levels were independent predictors of a malignant thyroid neoplasm (P < 0.003). The AUC was 0.956 for ECM1 and 0.926 for TMPRSS4. Combining both markers improved their diagnostic use (AUC 0.985; sensitivity, 91.7%; specificity, 89.8%; positive predictive value, 85.7%; negative predictive value, 82.8%). ECM1 and TMPRSS4 expression analysis improved the diagnostic accuracy of FNA biopsy in 35 of 38 indeterminate or suspicious results. The level of ECM1 mRNA expression was higher in TNM stage I differentiated thyroid cancers than in stage II and III tumors (P ≤ 0.031). Conclusions: ECM1 and TMPRSS4 are excellent

  2. Two-color immunostaining of liver fine needle aspiration biopsies with CD34 and carcinoembryonic antigen. Potential utilization in the diagnosis of primary hepatocellular carcinoma vs. metastatic tumor.

    PubMed

    Yoder, Michael; Zimmerman, Robert L; Bibbo, Marluce

    2004-04-01

    To examine immunohistochemical staining of cell block material with antibodies against vascular marker CD34 and polyclonal carcinoembryonic antigen (pCEA) for their clinical utility as part of a 2-color staining protocol in fine needle aspiration (FNA) biopsy of liver masses to distinguish metastases from primary hepatocellular carcinoma (HCC). The authors obtained cell block material from 96 liver FNAs and performed simultaneous (i.e., "dual-color") immunohistochemical staining utilizing antibodies against vascular marker CD34 and pCEA. Cases were blinded and evaluated by the authors for staining pattern and intensity. A consensus was obtained, the results were unblinded, and the diagnoses were correlated. After staining, 89 cases had sufficient tissue for evaluation. Of the 19 HCC cases, 16 (84%) showed peripheral staining with CD34, and 13 (68%) showed a canalicular or mixed canalicular-cytoplasmic staining pattern for pCEA. Thirteen cases (68%) showed staining for both antigens. All HCC exhibited immunostaining for at least 1 antibody in an appropriate staining pattern. Of the 67 cases of metastatic malignancy, 5 (7%) showed a predominantly transgressing pattern of CD34 staining, 43 (64%) showed a predominantly cytoplasmic or mixed cytoplasmic-canalicular pattern of pCEA staining, and 2 cases (3%) showed staining for both antigens in a transgressing CD34 pattern and cytoplasmic pCEA pattern. None of the 3 normal liver tissue blocks showed staining with either antigen. Two-color immunohistochemical staining of liver cell block material obtained by FNA with antibodies to CD34 and pCEA can be helpful in differentiating metastatic tumors vs. primary HCC.

  3. In vivo photoacoustic and ultrasonic mapping of rat sentinel lymph nodes with a modified commercial ultrasound imaging system

    NASA Astrophysics Data System (ADS)

    Erpelding, Todd N.; Kim, Chulhong; Pramanik, Manojit; Guo, Zijian; Dean, John; Jankovic, Ladislav; Maslov, Konstantin; Wang, Lihong V.

    2010-02-01

    Sentinel lymph node biopsy (SLNB) has become the standard method for axillary staging in breast cancer patients, relying on invasive identification of sentinel lymph nodes (SLNs) following injection of blue dye and radioactive tracers. While SLNB achieves a low false negative rate (5-10%), it is an invasive procedure requiring ionizing radiation. As an alternative to SLNB, ultrasound-guided fine needle aspiration biopsy has been tested clinically. However, ultrasound alone is unable to accurately identify which lymph nodes are sentinel. Therefore, a non-ionizing and noninvasive detection method for accurate SLN mapping is needed. In this study, we successfully imaged methylene blue dye accumulation in vivo in rat axillary lymph nodes using a Phillips iU22 ultrasound imaging system adapted for photoacoustic imaging with an Nd:YAG pumped, tunable dye laser. Photoacoustic images of rat SLNs clearly identify methylene blue dye accumulation within minutes following intradermal dye injection and co-registered photoacoustic/ultrasound images illustrate lymph node position relative to surrounding anatomy. To investigate clinical translation, the imaging depth was extended up to 2.5 cm by adding chicken breast tissue on top of the rat skin surface. These results raise confidence that photoacoustic imaging can be used clinically for accurate, noninvasive SLN mapping.

  4. Use of an Additional 19-G EBUS-TBNA Needle Increases the Diagnostic Yield of EBUS-TBNA.

    PubMed

    Garrison, Garth; Leclair, Timothy; Balla, Agnes; Wagner, Sarah; Butnor, Kelly; Anderson, Scott R; Kinsey, C Matthew

    2018-06-12

    Although endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has an excellent diagnostic yield, there remain cases where the diagnosis is not obtained. We hypothesized that additional sampling with a 19-G EBUS-TBNA needle may increase diagnostic yield in a subset of cases where additional tissue sampling was required. Indications for use of the 19-G needle following 22-G sampling with rapid on-site cytologic examination were: (1) diagnostic uncertainty of the on-site cytopathologist (eg, nondiagnostic, probable lymphoma, etc.), (2) non-small cell lung cancer with probable need for molecular genetic and/or PD-L1 testing, or (3) need for a larger tissue sample for consideration of inclusion in a research protocol. A 19-G EBUS-TBNA needle was utilized following standard sampling with a 22-G needle in 48 patients (50 sites) during the same procedure. Although the diagnostic yield between the needles was equivalent, the concordance rate was only 83%. The 19-G determined a diagnosis in 4 additional patients (8%) and provided additional histopathologic information in 6 other cases (12%). Conversely, in 3 cases (6%) diagnostic information was provided only by the 22-G needle. Compared with 22-G EBUS-TBNA alone, sampling with both the 22- and 19-G EBUS needles resulted in an increase in diagnostic yield from 92% to 99% (P=0.045) and a number needed to sample of 13 patients to provide one additional diagnosis. There were no significant complications. In select cases where additional tissue may be needed, sampling with a 19-G EBUS needle following standard aspiration with a 22-G needle results in an increase in diagnostic yield.

  5. Thyroid Ultrasound Pitfalls: Esophageal Fibrovascular Polyp Mimicking Thyroid Nodule

    PubMed Central

    Brigante, G.; Madeo, B.

    2016-01-01

    Background. Ultrasound (US) is the most accurate tool in the diagnosis of thyroid nodules if performed by expert physician. Misdiagnosis due to extrathyroidal lesions mimicking thyroid nodules is reported in literature. We describe the first case of an esophageal fibrovascular polyp misdiagnosed as a thyroid nodule on US examination. Patient Findings. A 54-year-old woman presented to emergency department for headache and underwent carotid Doppler extended to neck ultrasound with incidental finding of a nodule in the posterior side of the left thyroid lobe. A following thyroid US performed by an endocrinologist allowed the characterization of the lesion as an esophageal pathology, considering the extrathyroidal position, the typical peripheral hyperechoic spots and hypoechoic rim, the connection to the esophagus, and the swallowing connected movement. The patient was addressed to further investigations and finally to anterior pharyngotomy with histological diagnosis of esophageal fibrovascular polyp. Summary. Differential diagnosis between thyroid nodules and other neck lesions is important to prevent an unnecessary fine needle aspiration biopsy and to treat the extrathyroidal pathology. In this case, an US performed by an expert endocrinologist allowed detecting an esophageal fibrovascular polyp requiring surgical removal. In conclusion, the possibility of an esophageal pathology, and even fibrovascular polyp, should be considered during US thyroid examination. PMID:27022492

  6. Novel Magnetic Resonance Detection and Profiling of Ovarian Cancer Across Specimens

    DTIC Science & Technology

    2012-10-01

    Cancer Cells in Fine - Needle Aspirates. Proc. Natl. Acad. Sci. U.S.A. 2009, 106, 12459–12464. 25. Han,H. S.; Devaraj,N. K.; Lee, J.; Hilderbrand, S.A... fine needle aspirates, biopsies, ascites, blood, sputum), which are inherently complex in composition, as well as heterogeneous and variable in cell...in ascitic fluid, we anticipate that this method could similarly be applied to fine needle aspirates, blood, biopsy spec- imens, sputum, and other

  7. Integration of single-fiber reflectance spectroscopy into ultrasound-guided endoscopic lung cancer staging of mediastinal lymph nodes

    NASA Astrophysics Data System (ADS)

    Kanick, Stephen Chad; van der Leest, Cor; Aerts, Joachim G. J. V.; Hoogsteden, Henk C.; Kaščáková, Slávka; Sterenborg, Henricus J. C. M.; Amelink, Arjen

    2010-01-01

    We describe the incorporation of a single-fiber reflectance spectroscopy probe into the endoscopic ultrasound fine-needle aspiration (EUS-FNA) procedure utilized for lung cancer staging. A mathematical model is developed to extract information about the physiological and morphological properties of lymph tissue from single-fiber reflectance spectra, e.g., microvascular saturation, blood volume fraction, bilirubin concentration, average vessel diameter, and Mie slope. Model analysis of data from a clinical pilot study shows that the single-fiber reflectance measurement is capable of detecting differences in the physiology between normal and metastatic lymph nodes. Moreover, the clinical data show that probe manipulation within the lymph node can perturb the in vivo environment, a concern that must be carefully considered when developing a sampling strategy. The data show the feasibility of this novel technique; however, the potential clinical utility has yet to be determined.

  8. Core Needle Biopsy of the Thyroid: 2016 Consensus Statement and Recommendations from Korean Society of Thyroid Radiology

    PubMed Central

    Na, Dong Gyu; Jung, So Lyung; Kim, Ji-hoon; Sung, Jin Yong; Kim, Kyu Sun; Lee, Jeong Hyun; Shin, Jung Hee; Choi, Yoon Jung; Ha, Eun Ju; Lim, Hyun Kyung; Kim, Soo Jin; Hahn, Soo Yeon; Lee, Kwang Hwi; Choi, Young Jun; Youn, Inyoung; Kim, Young Joong; Ahn, Hye Shin; Ryu, Ji Hwa; Baek, Seon Mi; Sim, Jung Suk; Jung, Chan Kwon; Lee, Joon Hyung

    2017-01-01

    Core needle biopsy (CNB) has been suggested as a complementary diagnostic method to fine-needle aspiration in patients with thyroid nodules. Many recent CNB studies have suggested a more advanced role for CNB, but there are still no guidelines on its use. Therefore, the Task Force Committee of the Korean Society of Thyroid Radiology has developed the present consensus statement and recommendations for the role of CNB in the diagnosis of thyroid nodules. These recommendations are based on evidence from the current literature and expert consensus. PMID:28096731

  9. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    PubMed

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  10. Differences in accuracy and underestimation rates for 14- versus 16-gauge core needle biopsies in ultrasound-detectable breast lesions.

    PubMed

    Lai, Hung-Wen; Wu, Hwa-Koon; Kuo, Shou-Jen; Chen, Shou-Tung; Tseng, Hsin-Shun; Tseng, Ling-Ming; Chen, Dar-Ren

    2013-04-01

    Core needle biopsy (CNB) was widely used in the diagnosis of ultrasound-detectable breast lesions. We aimed at assessing the diagnostic performance differences between 14- and 16-gauge ultrasound-guided core biopsies. This retrospective study enrolled patients receiving CNB from January 2001 to December 2007. The results of 14- and 16-gauge breast CNBs were compared with pathology reports of open surgical biopsy (OSB). A total of 1024 paired CNB and OSB results were obtained from 1732 CNB procedures in 1630 patients.Those CNB results reached 92.9% sensitivity, 99.7% specificity, 5.96% underestimation, and 94.8% accuracy rates. There was no difference in sensitivity (p=0.17) or specificity (p=0.38) between 14- and 16-gauge needles. However, better overall accuracy (p=0.02), less underestimation (p<0.001), and lower false-negative (p=0.02) rates were found for the 14-gauge CNB. Regarding accuracy and underestimation rates, a 14-gauge needle is preferred to a 16-gauge one in ultrasound-guided biopsies. Copyright © 2012. Published by Elsevier B.V.

  11. Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses

    PubMed Central

    Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao

    2018-01-01

    Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650

  12. Detection of EGFR and KRAS mutations in fine-needle aspirates stored on Whatman FTA cards: is this the tool for biobanking cytological samples in the molecular era?

    PubMed

    da Cunha Santos, Gilda; Liu, Ni; Tsao, Ming-Sound; Kamel-Reid, Suzanne; Chin, Kayu; Geddie, William R

    2010-12-25

    The aims of this study were to compare the quality of DNA recovered from fine-needle aspirates (FNAs) stored on Whatman FTA cards with that retrieved from corresponding cell blocks and to determine whether the DNA extracted from the cards is suitable for multiple mutation analyses. FNAs collected from 18 resected lung tumors and cell suspensions from 4 lung cancer cell lines were placed on FTA Indicating Micro Cards and further processed to produce paired formalin-fixed paraffin-embedded (FFPE) cell blocks. Fragment analysis was used for the detection of EGFR exon 19 deletion, and direct sequencing for detection of EGFR exon 21 L858R mutation and exon 2 deletion of KRAS. Corresponding FFPE tissue sections from 2 resection specimens were also tested. Analyses were successful with all FNAs and lung cancer-derived cell lines collected on cards. Polymerase chain reaction failed in 2 cell blocks. For FNAs collected on cards, 5 cases showed EGFR and 3 showed KRAS mutations. Eleven cases were wild type. With cell blocks, 4 cases were found to harbor KRAS and 4 harbored EGFR mutations. All lung cancer-derived cell lines tested positive for their respective mutations, and there was complete agreement between card and cell block FNA samples for EGFR exon 21. For EGFR exon 19, 1 of 18 cases showed discordant results between the card and cell block, and for KRAS 1 of 17. The two resection specimens tested gave concordant results with the FTA card. Storage of cytologic material on FTA cards can maximize and simplify sample procurement for multiple mutational analyses with results similar to those from cell blocks.

  13. Clinico-pathological Correlation of Thyroid Nodule Ultrasound and Cytology Using the TIRADS and Bethesda Classifications.

    PubMed

    Singaporewalla, R M; Hwee, J; Lang, T U; Desai, V

    2017-07-01

    Clinico-pathological correlation of thyroid nodules is not routinely performed as until recently there was no objective classification system for reporting thyroid nodules on ultrasound. We compared the Thyroid Imaging Reporting and Data System (TIRADS) of classifying thyroid nodules on ultrasound with the findings on fine-needle aspiration cytology (FNAC) reported using the Bethesda System. A retrospective analysis of 100 consecutive cases over 1 year (Jan-Dec 2015) was performed comparing single-surgeon-performed bedside thyroid nodule ultrasound findings based on the TIRADS classification to the FNAC report based on the Bethesda Classification. TIRADS 1 (normal thyroid gland) and biopsy-proven malignancy referred by other clinicians were excluded. Benign-appearing nodules were reported as TIRADS 2 and 3. Indeterminate or suspected follicular lesions were reported as TIRADS 4, and malignant-appearing nodules were classified as TIRADS 5 during surgeon-performed bedside ultrasound. All the nodules were subjected to ultrasound-guided FNAC, and TIRADS findings were compared to Bethesda FNAC Classification. Of the 100 cases, 74 were considered benign or probably benign, 20 were suspicious for malignancy, and 6 were indeterminate on ultrasound. Overall concordance rate with FNAC was 83% with sensitivity and specificity of 70.6 and 90.4%, respectively. The negative predictive value was 93.8%. It is essential for clinicians performing bedside ultrasound thyroid and guided FNAC to document their sonographic impression of the nodule in an objective fashion using the TIRADS classification and correlate with the gold standard cytology to improve their learning curve and audit their results.

  14. The integration of single fiber reflectance (SFR) spectroscopy during endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) in pancreatic masses: a feasibility study

    NASA Astrophysics Data System (ADS)

    Stegehuis, Paulien L.; Boogerd, Leonora S. F.; Inderson, Akin; Veenendaal, Roeland A.; Bonsing, Bert A.; Amelink, Arjen; Vahrmeijer, Alexander L.; Dijkstra, Jouke; Robinson, Dominic J.

    2016-03-01

    EUS-FNA can be used for pathological confirmation of a suspicious pancreatic mass. However, performance depends on an on-site cytologist and time between punction and final pathology results can be long. SFR spectroscopy is capable of extracting biologically relevant parameters (e.g. oxygenation and blood volume) in real-time from a very small tissue volume at difficult locations. In this study we determined feasibility of the integration of SFR spectroscopy during EUSFNA procedures in pancreatic masses. Patients with benign and malignant pancreatic masses who were scheduled for an EUS-FNA were included. The working guide wire inside the 19 gauge endoscopic biopsy needle was removed and the sterile single fiber (300 μm core and 700 μm outer diameter, wide-angle beam, NA 0.22) inserted through the needle. Spectroscopy measurements in the visiblenear infrared wavelength region (400-900 nm) and autofluorescence measurements (excitation at 405 nm) were taken three times, and subsequently cytology was obtained. Wavelength dependent optical properties were compared to cytology results. We took measurements in 13 patients with corresponding cytology results (including mucinous tumor, ductal adenocarcinoma, neuroendocrine tumor, and pancreatitis). In this paper we show the first analyzed results comparing normal pancreatic tissue with cancerous tissue in the same patient. We found a large difference in blood volume fraction, and blood oxygenation was higher in normal tissue. Integration of SFR spectroscopy is feasible in EUS-FNA procedures, the workflow hardly requires changes and it takes little time. The first results differentiating normal from tumor tissue are promising.

  15. Autonomic Responses to Ultrasound-Guided Percutaneous Needle Electrolysis: Effect of Needle Puncture or Electrical Current?

    PubMed

    García Bermejo, Paula; De La Cruz Torres, Blanca; Naranjo Orellana, José; Albornoz Cabello, Manuel

    2018-01-01

    The aim of this study was to establish if the changes in sympathetic and parasympathetic activity (analyzed through heart-rate variability [HRV]) during ultrasound (US)-guided percutaneous needle electrolysis (PNE) is due to the effect of needle puncture only or of the PNE technique per se where the puncture and galvanic current are combined. This was an experimental, case-control study that took place at the University of Seville. Subjects were 36 male footballers who were randomly allocated to three groups: a control group (CG; 12 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; a first experimental group (PNE group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE in the patellar tendon; and a second experimental group (needle group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE without electrical current in the patellar tendon. The outcome measures were the diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between CG measurements (baseline vs. intervention). The PNE group exhibited statistically significant increases in SD1 (p = 0.01) and SD2 (p = 0.004) and statistically significant decreases in SS and S/PS ratio (p = 0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. The needle group exhibited statistically significant increases in SD2 (p = 0.02) and statistically significant decreases in SS (p = 0.02), indicating decreased sympathetic activity. The application of the US-guided PNE technique caused a measurable increase in parasympathetic activity (detected by HRV), which was due to the combination of needle puncture and

  16. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    PubMed

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (p<0.001). There was no difference between the AUC of conventional ultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  17. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.

    2017-03-01

    Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.

  18. Automatic needle segmentation in 3D ultrasound images using 3D Hough transform

    NASA Astrophysics Data System (ADS)

    Zhou, Hua; Qiu, Wu; Ding, Mingyue; Zhang, Songgeng

    2007-12-01

    3D ultrasound (US) is a new technology that can be used for a variety of diagnostic applications, such as obstetrical, vascular, and urological imaging, and has been explored greatly potential in the applications of image-guided surgery and therapy. Uterine adenoma and uterine bleeding are the two most prevalent diseases in Chinese woman, and a minimally invasive ablation system using an RF button electrode which is needle-like is being used to destroy tumor cells or stop bleeding currently. Now a 3D US guidance system has been developed to avoid accidents or death of the patient by inaccurate localizations of the electrode and the tumor position during treatment. In this paper, we described two automated techniques, the 3D Hough Transform (3DHT) and the 3D Randomized Hough Transform (3DRHT), which is potentially fast, accurate, and robust to provide needle segmentation in 3D US image for use of 3D US imaging guidance. Based on the representation (Φ , θ , ρ , α ) of straight lines in 3D space, we used the 3DHT algorithm to segment needles successfully assumed that the approximate needle position and orientation are known in priori. The 3DRHT algorithm was developed to detect needles quickly without any information of the 3D US images. The needle segmentation techniques were evaluated using the 3D US images acquired by scanning water phantoms. The experiments demonstrated the feasibility of two 3D needle segmentation algorithms described in this paper.

  19. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    PubMed

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. A Novel Technology for Localization of Parathyroid Adenoma: Ultrasound-Guided Fine Needle Aspiration Combined With Rapid Parathyroid Hormone Detection and Nano-Carbon Technology.

    PubMed

    Yan, Shouyi; Zhao, Wenxin; Wang, Bo; Zhang, Liyong

    2018-06-01

    The study aims to evaluate the clinic feasibility of rapid parathyroid hormone (PTH) detection and nano-carbon technology in preoperative diagnosis and localization of parathyroid adenoma. With the guidance of ultrasound, the operator performed the parathyroid puncture and tested the PTH value by using a PTH test kit, and then injected nano-carbon into parathyroid adenoma as a marker to observe whether the parathyroid adenoma was stained black during the final operation. Meanwhile, a part of excised specimen was made into homogenate and detected rapidly again by using the PTH test kit. The remaining was confirmed by intraoperative frozen pathological examination. The sensitivity (12/12) of preoperative diagnosis was significantly higher than that of ultrasound (6/12), magnetic resonance imaging (7/12), and MIBI (9/12). During the operation, we found that the inner part of the parathyroid adenoma was stained black, and the PTH value of the specimen homogenate confirmed as parathyroid adenoma was more than 3000 pg/mL. This novel technology, as a very positive method for localization of parathyroid adenoma, plays an important role in guaranteeing the surgical reliability of parathyroid adenoma with help of nano-carbon technology.

  1. [A case of pulmonary abscess in which Haemophilus parainfluenzae and Streptococcus intermedius were isolated by percutaneous needle aspiration].

    PubMed

    Miyamoto, Atsushi; Tsuboi, Eiyasu; Takaya, Hisashi; Sugino, Keishi; Sakamoto, Susumu; Kawabata, Masateru; Kishi, Kazuma; Narui, Koji; Homma, Sakae; Nakatani, Tatsuo; Nakata, Koichiro; Yoshimura, Kunihiko

    2006-08-01

    Some microbes, including the Bacteroides species, Staphylococcus aureus and Streptococcus milleri groups, can cause pulmonary abscess. Haemophilus parainfluenzae is usually categorized as one of the normal flora which colonizes in the ears and the nasopharynx, and it has been long considered that H. parainfluenzae has little pathogenicity in the lower respiratory tract and lung parenchymal. In this report, we present a case of pulmonary abscess caused by both H. parainfluenzae and Streptococcus intermedius. The patient was a 75-year-old man who had had total esophageo-gastrectomy because of esophageal cancer. He presented with purulent sputum, and chest X-ray film showed a dense consolidation in the right upper lung field. CT-guided transcutaneous fine needle aspiration was performed as a diagnostic procedure. Since both H. parainfluenzae and S. intermedius had been isolated from the lesion, pulmonary abscess caused by these two pathogens was diagnosed. The patient was treated with panipenem/betamipron, and his symptoms and pulmonary infiltrates on the chest X-ray film improved thereafter. So far, very few cases have been reported in which H. parainfluenzae caused lower respiratory tract infection. Although S. intermedius is known as one of the pathogens of pulmonary abscess, it is possible that H. parainfluenzae could also be pathogenic in infectious diseases of the lung.

  2. Realistic and affordable lo-fidelity model for learning bronchoscopic transbronchial needle aspiration.

    PubMed

    Goldberg, Robert; Colt, Henri G; Davoudi, Mohsen; Cherrison, Larry

    2009-09-01

    Transbronchial needle aspiration (TBNA) is used to sample mediastinal abnormalities and lymph node stations for diagnostic purposes and lung cancer staging. The procedure is underused, operator dependent, and reputed to have a steep learning curve. Other difficulties arise from a bronchoscopist's failure to insert the needle satisfactorily into the target node. The purpose of this study was to evaluate the realism and helpfulness of a lo-fidelity, easily constructed hybrid model used for learning and practicing TBNA. The model is constructed by attaching a porcine tracheobronchial tree to a Laerdal Airway Model mounted on polyvinyl chloride (PVC) piping. Twelve individuals with various levels of bronchoscopy training and experience were given a 15-min introductory PowerPoint presentation on TBNA strategy and planning, execution, and response to complications. Participants then practiced TBNA alone and with guidance, aided by an assistant, as many times as individually necessary to feel comfortable with the procedure. A five-point Likert scale 8-item questionnaire was then completed. Participants were unanimously positive about their experience (mean scores 4.25-4.91). The model was realistic, provided increased comfort with TBNA techniques, and allowed practice of communication skills. This realistic, affordable, and easily constructed hybrid lo-fidelity airway model allows beginner and experienced bronchoscopists opportunities to learn and practice basic TBNA techniques and team communication skills without placing patients at risk.

  3. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  4. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    NASA Astrophysics Data System (ADS)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  5. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat

    2008-02-15

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsymore » procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced

  6. Mistakes in ultrasound examination of salivary glands

    PubMed Central

    Jakubowski, Wiesław

    2016-01-01

    Ultrasonography is the first imaging method applied in the case of diseases of the salivary glands. The article discusses basic mistakes that can be made during an ultrasound examination of these structures. The reasons for these mistakes may be examiner-dependent or may be beyond their control. The latter may include, inter alia, difficult conditions during examination (technical or patient-related), similarity of ultrasound images in different diseases, the lack of clinical and laboratory data as well as the lack of results of other examinations, their insufficient number or incorrectness. Doctor-related mistakes include: the lack of knowledge of normal anatomy, characteristics of ultrasound images in various salivary gland diseases and statistical incidence of diseases, but also attaching excessive importance to such statistical data. The complex anatomical structures of the floor of the oral cavity may be mistaken for benign or malignant tumors. Fragments of correct anatomical structures (bones, arterial wall fibrosis, air bubbles in the mouth) can be wrongly interpreted as deposits in the salivary gland or in its excretory duct. Correct lymph nodes in the parotid glands may be treated as pathologic structures. Lesions not being a simple cyst, e.g. lymphoma, benign or malignant tumors of the salivary glands or metastatic lymph nodes, can be mistaken for one. The image of disseminated focal changes, both anechoic and solid, is not pathognomonic for specific diseases in the salivary glands. However, in part, it occurs typically and requires an extended differential diagnosis. Small focal changes and infiltrative lesions pose a diagnostic problem because their etiology cannot be safely suggested on the basis of an ultrasound examination itself. The safest approach is to refer patients with abnormal focal changes for an ultrasoundguided fine-needle aspiration biopsy. PMID:27446603

  7. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    PubMed

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or

  8. Broadsheet number 57: problems in fine needle biopsy of the thyroid.

    PubMed

    Orell, S R; Philips, J

    2000-08-01

    The role of fine needle biopsy and cytological diagnosis in the preoperative evaluation of thyroid nodules is reviewed on the basis of the current literature as well as the authors' personal experience. Technical aspects and guidelines for reporting thyroid samples are discussed in some detail. The main emphasis is on diagnostic pitfalls, those which may lead to a false-negative diagnosis, to a false-positive diagnosis or to an erroneous typing of the lesion, and their cytological patterns are described.

  9. Development of 3D ultrasound needle guidance for high-dose-rate interstitial brachytherapy of gynaecological cancers

    NASA Astrophysics Data System (ADS)

    Rodgers, J.; Tessier, D.; D'Souza, D.; Leung, E.; Hajdok, G.; Fenster, A.

    2016-04-01

    High-dose-rate (HDR) interstitial brachytherapy is often included in standard-of-care for gynaecological cancers. Needles are currently inserted through a perineal template without any standard real-time imaging modality to assist needle guidance, causing physicians to rely on pre-operative imaging, clinical examination, and experience. While two-dimensional (2D) ultrasound (US) is sometimes used for real-time guidance, visualization of needle placement and depth is difficult and subject to variability and inaccuracy in 2D images. The close proximity to critical organs, in particular the rectum and bladder, can lead to serious complications. We have developed a three-dimensional (3D) transrectal US system and are investigating its use for intra-operative visualization of needle positions used in HDR gynaecological brachytherapy. As a proof-of-concept, four patients were imaged with post-insertion 3D US and x-ray CT. Using software developed in our laboratory, manual rigid registration of the two modalities was performed based on the perineal template's vaginal cylinder. The needle tip and a second point along the needle path were identified for each needle visible in US. The difference between modalities in the needle trajectory and needle tip position was calculated for each identified needle. For the 60 needles placed, the mean trajectory difference was 3.23 +/- 1.65° across the 53 visible needle paths and the mean difference in needle tip position was 3.89 +/- 1.92 mm across the 48 visible needles tips. Based on the preliminary results, 3D transrectal US shows potential for the development of a 3D US-based needle guidance system for interstitial gynaecological brachytherapy.

  10. Aspiration and Biopsy: Bone Marrow

    MedlinePlus

    ... Print What It Is Bone marrow aspirations and biopsies are performed to examine bone marrow, the spongy liquid part of the bone where blood cells are ... you might also feel the pressure of the biopsy needle pushing in. Some ... sharp cramp as the liquid bone marrow is withdrawn for the aspiration or ...

  11. KRAS mutation analysis of washing fluid from endoscopic ultrasound-guided fine needle aspiration improves cytologic diagnosis of pancreatic ductal adenocarcinoma.

    PubMed

    Park, Joo Kyung; Lee, Yoon Jung; Lee, Jong Kyun; Lee, Kyu Taek; Choi, Yoon-La; Lee, Kwang Hyuck

    2017-01-10

    EUS-FNA becomes one of the most important diagnostic modalities for PDACs. However, acquired tissue specimens were sometimes insufficient to make a definite cytological diagnosis. On the other hand, KRAS mutation is the most frequently acquired genetic alteration found more than 90% of PDACs. To investigate the way to improve diagnostic accuracy for PDACs using both cytological examination and KRAS mutation analysis would be a great help. Therefore, the aims of this study were to evaluate usefulness of conventional cytological examination combined with KRAS mutation analysis with modified PCR technology to improve the sensitivity and the accuracy. We enrolled 43 patients with solid pancreatic masses and 86 EUS-FNA specimens were obtained. During the EUS-FNA, the needle catheter was flushed with 2 cc of saline and the washed fluid was collected for KRAS mutation analysis for the first 2 passes; PNAClamp™ KRAS Mutation Detection Kit. There were 46 specimens from the 23 PDACs and 40 specimens from the 20 other pancreatic diseases. The sensitivity, specificity and accuracy were as follows; conventional cytopathologic examination: 63%, 100% and 80%; combination of cytopathologic examination and K-ras mutation analysis: 87%, 100% and 93%. Furthermore, KRAS mutation was detected 11 out of 17 PDAC samples whose cytopathology results were inconclusive. KRAS mutation analysis with PNAClamp™ technique using washing fluid from EUS-FNA along with cytological examination may not only improve the diagnostic accuracy of PDACs, but also establish the platform using genetic analysis which would be helpful as diagnostic modality for PDACs.

  12. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    PubMed

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  13. The use of the Bethesda terminology in thyroid fine-needle aspiration results in a lower rate of surgery for nonmalignant nodules: a report from a reference center in Turkey.

    PubMed

    Ozluk, Yasemin; Pehlivan, Esmehan; Gulluoglu, Mine G; Poyanli, Arzu; Salmaslioglu, Artur; Colak, Nese; Kapran, Yersu; Yilmazbayhan, Dilek

    2011-12-01

    The Bethesda system (BS) for reporting thyroid fine-needle aspiration (FNA), which classifies nodules as nondiagnostic (ND), benign (B), atypia/follicular lesion of undetermined significance (AUS/FLUS), suspicious for follicular neoplasm (SFN/FN), suspicious for malignancy (SFM), or malignant (M), uses clinically valuable management guidelines. The authors employed a similar in-house classification system (IS) for thyroid FNAs, using the categories of ND, B, suspicious follicular cells (SFC), follicular lesion/neoplasm (FL/FN), SFM, and M. The authors compared IS and BS, and assessed the utility of BS in clinical practice. A total of 581 nodules with cytological/histological follow-up were examined and indeterminate lesions by BS were reclassified. The sensitivity and specificity for malignancy using IS were similar to that of BS (77% vs 99%). However, when SFN/FN and SFM were both considered positive, the results for IS and BS were as follows: sensitivity, 85% versus 85%; specificity, 87% versus 94%; and diagnostic accuracy, 86% versus 90%, respectively. Discrepancies between cytological and histological data were evident in 35 cases among all categories of BS except AUS/FLUS. The rate of surgery for nonmalignant nodules was lesser (20% vs 9%) by BS. Among 34 AUS/FLUS cases with follow-up data, hypocellularity was the case in 11 (46%) nonneoplastic and 10 (100%) neoplastic nodules. The use of BS results in a lower rate of surgery for nonmalignant nodules even though patients with borderline cytopathologic features are still encountered. AUS/FLUS category can be separated into subgroups according to the factors causing difficulties in the interpretation. There is a need of accumulation of AUS/FLUS cases to do further evaluations and studies.

  14. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle

  15. Double-pointed 30-gauge needle for keratocentesis.

    PubMed

    Angi, M R; Endara, N I

    1985-12-01

    A new, efficient instrument for performing keratocentesis for aqueous humour aspiration and anterior chamber microinfusion is described. It consists of a double-pointed 30-gauge needle, a liquid container (a nonflexible vinyl tube plugged at one end with a rubber stopper) and a aspiration-infusion syringe connected to the container and needle by a flexible vinyl tube. The instrument's advantages are a safer technique, complete collection of the aqueous humour and better handling of the sample.

  16. Videothoracoscopy in the treatment of mediastinal cysts

    PubMed Central

    Brzeziński, Daniel; Kozak, Józef

    2014-01-01

    Introduction Progress in the development of surgical techniques has led to the growing use of video-assisted thoracoscopic surgery (VATS) techniques in mediastinal cyst treatment. Aim To present our experience of treating mediastinal cysts with the minimally invasive technique. Material and methods Fifty patients with mediastinal cysts were treated from 2001 to 2011. There were 32 women and 18 men. The age of the patients ranged from 17 to 72, the mean age being 42 years. All patients underwent basic preoperative diagnostic tests of the chest: X-ray, computed tomography (CT), bronchoscopy and spirometry; 4 patients underwent endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and 3 fine needle aspiration biopsy (FNAB) of the described lesions. Results The VATS was performed in each case. Conversion was carried out due to superior mediastinal location in 10 cases and pleural adhesions in 3 cases. The partial resection of a cyst was performed in 3 patients. One patient was treated conservatively due to heart failure. In that patient the transthoracic needle aspiration of a cyst under ultrasound guidance using alcoholisation with 76% ethanol with a good effect was performed twice. Cyst recurrence was observed in 1 case. Conclusions The surgical access depends on the location of a cyst. The VATS resection of a superior mediastinal cyst is not always feasible. Surgery of mediastinal cysts is both diagnostic and curative. PMID:25337163

  17. The diagnostic utility of Merkel cell polyomavirus immunohistochemistry in a fine needle aspirate of metastatic Merkel cell carcinoma of unknown primary to the pancreas.

    PubMed

    Li, Long; Molberg, Kyle; Cheedella, Naga; Thibodeaux, Joel; Hinson, Stacy; Lucas, Elena

    2018-01-01

    Merkel cell carcinoma (MCC) is an aggressive skin tumor with a high tendency for metastases. We report a case of MCC initially presenting as axillary and pancreatic metastases. A 33-year-old HIV-positive Hispanic male presented with a history of a rapidly growing axillary mass. A needle core biopsy demonstrated an epithelioid neoplasm composed of small to medium-sized cells with high nuclear-cytoplasmic ratio, nuclear molding, and frequent mitotic figures. A subsequent PET scan revealed a 1.5 cm FDG avid mass in the pancreas. Endoscopic ultrasound-guided FNA of the pancreatic mass showed neoplastic cells with similar morphology to those of the axillary mass. The tumor cells were positive with pancytokeratin AE1/AE3, CK20, CD56, synatophysin, chromogranin, and Merkel cell polyomavirus (MCPyV). This case of MCC most likely originated from a resolved primary skin lesion drained by the involved axillary lymph node with subsequent metastases to the pancreas and distant lymph nodes. © 2017 Wiley Periodicals, Inc.

  18. The value of the repeated examination of BRAF V600E mutation status in diagnostics of papillary thyroid cancer.

    PubMed

    Beiša, Augustas; Beiša, Virgilijus; Stoškus, Mindaugas; Ostanevičiūtė, Elvyra; Griškevičius, Laimonas; Strupas, Kęstutis

    2016-01-01

    Nodular thyroid disease is one of the most frequently diagnosed pathologies of the adult population in iodine-deficient regions. Approximately 30% of thyroid aspirates are classified as nondiagnostic/unsatisfactory or indeterminate. However, patients with indeterminate cytology still undergo surgery. The object of this study was to determine the diagnostic value of re-examining the BRAF V600E mutation in papillary thyroid carcinoma patients. All patients underwent ultrasound guided fine-needle aspiration of a thyroid nodule. They were assigned to one of the four groups (indeterminate or positive for malignant cells) of the Bethesda System for Reporting Thyroid Cytopathology. Genetic investigation of the BRAF V600E mutation was performed for all of the fine-needle aspiration cytology specimens. All of the patients underwent surgery. Subsequently, histological investigation of the removed tissues was performed. Additional analysis of the BRAF V600E mutation from the histology specimen was then performed for the initially BRAF-negative cases. Two hundred and fourteen patients were involved in the study. One hundred and six (49.53%) patients were diagnosed with thyroid cancer. Of these 106 patients, 95 (89.62%) patients were diagnosed with papillary thyroid cancer. The BRAF V600E mutation was positive in 62 (65.26%) and negative in 33 (34.74%) histologically confirmed papillary thyroid cancer cases. After the genetic investigation, a total of 74 (77.89%) papillary thyroid cancer cases were positive for the BRAF V600E mutation and 21 (22.11%) were negative. Repeated examination of the BRAF V600E mutation status in the fine-needle aspiration may potentially increase the sensitivity of papillary thyroid cancer diagnostics.

  19. The utility of ultrasound in patients with melanoma.

    PubMed

    Uren, Roger F; Sanki, Amira; Thompson, John F

    2007-11-01

    The highest quality gray-scale ultrasound images are obtained with high-frequency transducers; however, such high frequencies do not penetrate more than a few centimeters into body tissue. Fortunately, in patients with melanoma, the structures of interest are close to the skin surface, making them ideal targets for examination with high-resolution ultrasound. These include primary cutaneous melanomas, uveal melanomas and the regional lymph nodes draining the skin that lie in the axilla, groin, neck and other locations. Although ultrasound study of primary melanomas arising in the skin and eye has provided some insights, a major role for ultrasound has evolved recently, to provide early detection of metastatic melanoma in regional lymph nodes. Ultrasound is clearly superior to clinical palpation of the nodes during follow-up and, when combined with guided fine-needle biopsy, allows the earliest possible surgical intervention for regional nodal metastases. In the future the use of ultrasound contrast agents may improve the sensitivity of ultrasound in the detection of very small metastatic deposits.

  20. Ultrasound findings of diffuse metastasis of gastric signet-ring-cell carcinoma to the thyroid gland.

    PubMed

    Morita, Koji; Sakamoto, Takahiko; Ota, Shuji; Masugi, Hideo; Chikuta, Ikumi; Mashimo, Yamato; Edo, Naoki; Tokairin, Takuo; Seki, Nobuhiko; Ishikawa, Toshio

    2017-01-01

    It has been shown that metastases to the thyroid from extrathyroidal malignancies occur as solitary or multiple nodules, or may involve the whole thyroid gland diffusely. However, diffuse metastasis of gastric cancer to the thyroid is extremely rare. Here, we report a case of a 74-year-old woman with diffuse infiltration of gastric adenocarcinoma (signet-ring-cell carcinoma/poorly differentiated adenocarcinoma) cells in the thyroid. The pathological diagnosis was made based on upper gastrointestinal endoscopy with biopsy and fine-needle aspiration cytology of the thyroid. An 18F-FDG PET/CT revealed multiple lesions with increased uptake, including the bilateral thyroid gland. On thyroid ultrasound examination, diffuse enlargement with internal heterogeneity and hypoechoic reticular lines was observed. On color Doppler imaging, a blood-flow signal was not detected in these hypoechoic lines. These findings were similar to those of diffuse metastases caused by other primary cancers, such as lung cancer, as reported earlier. Therefore, the presence of hypoechoic reticular lines without blood-flow signals is probably common to diffuse thyroid metastasis from any origin and an important diagnostic finding. This is the first report to show detailed ultrasound findings of diffuse gastric cancer metastasis to the thyroid gland using color Doppler.