Sample records for ultrasound guided biopsy

  1. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  2. Ultrasound-guided chest biopsies.

    PubMed

    Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar

    2006-12-01

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.

  3. Outcomes of ultrasound guided renal mass biopsies.

    PubMed

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  4. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  5. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  6. Analysis of "dry" mesothelioma with ultrasound guided biopsies.

    PubMed

    Stigt, Jos A; Boers, James E; Groen, Harry J M

    2012-12-01

    Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  8. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    PubMed

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  9. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a

  10. Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.

    PubMed

    Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason

    2017-05-01

    To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.

  11. Prospective randomized trial comparing magnetic resonance imaging (MRI)-guided in-bore biopsy to MRI-ultrasound fusion and transrectal ultrasound-guided prostate biopsy in patients with prior negative biopsies.

    PubMed

    Arsov, Christian; Rabenalt, Robert; Blondin, Dirk; Quentin, Michael; Hiester, Andreas; Godehardt, Erhard; Gabbert, Helmut E; Becker, Nikolaus; Antoch, Gerald; Albers, Peter; Schimmöller, Lars

    2015-10-01

    A significant proportion of prostate cancers (PCas) are missed by conventional transrectal ultrasound-guided biopsy (TRUS-GB). It remains unclear whether the combined approach using targeted magnetic resonance imaging (MRI)-ultrasound fusion-guided biopsy (FUS-GB) and systematic TRUS-GB is superior to targeted MRI-guided in-bore biopsy (IB-GB) for PCa detection. To compare PCa detection between IB-GB alone and FUS-GB + TRUS-GB in patients with at least one negative TRUS-GB and prostate-specific antigen ≥4 ng/ml. Patients were prospectively randomized after multiparametric prostate MRI to IB-GB (arm A) or FUS-GB + TRUS-GB (arm B) from November 2011 to July 2014. The study was powered at 80% to demonstrate an overall PCa detection rate of ≥60% in arm B compared to 40% in arm A. Secondary endpoints were the distribution of highest Gleason scores, the rate of detection of significant PCa (Gleason ≥7), the number of biopsy cores to detect one (significant) PCa, the positivity rate for biopsy cores, and tumor involvement per biopsy core. The study was halted after interim analysis because the primary endpoint was not met. The trial enrolled 267 patients, of whom 210 were analyzed (106 randomized to arm A and 104 to arm B). PCa detection was 37% in arm A and 39% in arm B (95% confidence interval for difference, -16% to 11%; p=0.7). Detection rates for significant PCa (29% vs 32%; p=0.7) and the highest percentage tumor involvement per biopsy core (48% vs 42%; p=0.4) were similar between the arms. The mean number of cores was 5.6 versus 17 (p<0.001). A limitation is the limited number of patients because of early cessation of accrual. This trial failed to identify an important improvement in detection rate for the combined biopsy approach over MRI-targeted biopsy alone. A prospective comparison between MRI-targeted biopsy alone and systematic TRUS-GB is justified. Our randomized study showed similar prostate cancer detection rates between targeted prostate biopsy

  12. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    NASA Astrophysics Data System (ADS)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  13. Development of a 3D ultrasound-guided prostate biopsy system

    NASA Astrophysics Data System (ADS)

    Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron

    2007-03-01

    Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.

  14. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of

  15. Ultrasound-Guided Abrams Pleural Biopsy vs CT-Guided Tru-Cut Pleural Biopsy in Malignant Pleural Disease, a 3-Year Follow-up Study.

    PubMed

    Sivakumar, Parthipan; Jayaram, Deepak; Rao, Deepak; Dhileepan, Vignesh; Ahmed, Irfan; Ahmed, Liju

    2016-12-01

    Conventional Abrams biopsy shows low sensitivity in suspected malignant pleural disease. There are limited data on the improvement in sensitivity by adding in image guidance. This retrospective study compares the diagnostic sensitivity of Abrams biopsy using ultrasound guidance with CT-guided Tru-Cut biopsy in suspected malignant pleural disease. Data were collected from 2006 to 2012 of patients who underwent image-guided biopsies for suspected non-tuberculous pleural disease. Data were collected on the result of the initial biopsy and final patient diagnosis as of June 2015. Sixty-three patients underwent image-guided Abrams biopsy and 29 underwent CT-guided Tru-Cut biopsies. The sensitivity of Abrams was 71.43 % compared to 75 % in the CT-guided Tru-Cut group. Specificity was 100 % in both groups. Image-guided Abrams biopsies demonstrate comparable diagnostic sensitivity in malignant pleural disease to CT-guided Tru-Cut biopsy.

  16. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    PubMed

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  17. Penthrox inhaler analgesia in transrectal ultrasound-guided prostate biopsy.

    PubMed

    Lee, Chanyang; Woo, Henry H

    2015-06-01

    Periprostatic injection of local anaesthetic (PILA) has been shown to significantly reduce pain in patients undergoing transrectal ultrasound-guided prostate biopsy (TRUSPB). However, this method does not address pain that is associated with ultrasound probe insertion, and the injection of local anaesthetic itself causes pain. The aim of this study was to explore the efficacy of methoxyflurane delivered by a Penthrox inhaler as a novel method of pain relief during TRUSPB. From July 2012 to July 2013, 64 patients were scheduled at a single centre to undergo TRUSPB while receiving analgesia via Penthrox inhaler. Fifteen minutes after the biopsy procedure, these patients were asked to complete a pain score survey using a 10-cm visual analogue scale (VAS) to separately report the degree of pain experienced during digital rectal examination (DRE), ultrasound probe insertion and core biopsy. The median pain scores on a 10-cm VAS were 2.0, 2.4 and 3.0 during DRE, probe insertion and needle biopsy, respectively, while using the Penthrox inhaler. Of the 64 patients, 11 had undergone TRUSPB previously receiving PILA. In these patients, PILA was significantly better than the Penthrox inhaler for pain relief during needle biopsy (median pain score 2.0 versus 4.0; P = 0.012). The Penthrox inhaler appears to be a safe and effective method of analgesia for TRUSPB. Patients who had experienced both PILA and Penthrox reported pain scores that significantly favoured PILA over the Penthrox inhaler. © 2014 Royal Australasian College of Surgeons.

  18. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  19. Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

    PubMed Central

    Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung

    2017-01-01

    Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656

  20. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  1. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion.

    PubMed

    Venderink, Wulphert; Govers, Tim M; de Rooij, Maarten; Fütterer, Jurgen J; Sedelaar, J P Michiel

    2017-05-01

    Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. A decision tree and Markov model were developed to compare cost-effectiveness. Literature review and expert opinion were used as input. A strategy was deemed cost-effective if the costs of gaining one quality-adjusted life year (incremental cost-effectiveness ratio) did not exceed the willingness-to-pay threshold of €80,000 (≈$85,000 in January 2017). A base case analysis was performed to compare systematic transrectal ultrasound- and image fusion-guided biopsies. Because of a lack of appropriate literature regarding the accuracy of direct in-bore MRI-guided biopsy, a threshold analysis was performed. The incremental cost-effectiveness ratio for fusion-guided biopsy compared with systematic transrectal ultrasound-guided biopsy was €1386 ($1470) per quality-adjusted life year gained, which was below the willingness-to-pay threshold and thus assumed cost-effective. If MRI findings are normal in a patient with clinically significant prostate cancer, the sensitivity of direct in-bore MRI-guided biopsy has to be at least 88.8%. If that is the case, the incremental cost-effectiveness ratio is €80,000 per quality-adjusted life year gained and thus cost-effective. Fusion-guided biopsy seems to be cost-effective compared with systematic transrectal ultrasound-guided biopsy. Future research is needed to determine whether direct in-bore MRI-guided biopsy is the best pathway; in this study a threshold was calculated at which it would be cost-effective.

  2. Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys.

    PubMed

    Nyman, R S; Cappelen-Smith, J; al Suhaibani, H; Alfurayh, O; Shakweer, W; Akhtar, M

    1997-05-01

    To compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. A total of 448 biopsies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. The gun-biopsies were performed under real-time ultrasound (US) guidance. The manual technique used US mainly for marking the position of the kidney. There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group. Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.

  3. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    PubMed

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  4. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    PubMed Central

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  5. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    PubMed

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  6. Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses

    PubMed Central

    Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao

    2018-01-01

    Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650

  7. A pitfall during endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes.

    PubMed

    Krenke, Rafal; Korczynski, Piotr; Gorska, Katarzyna; Chazan, Ryszarda

    2014-03-01

    The high diagnostic yield and favorable safety profile of endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes have been recently demonstrated. We report an unusual technical problem during endobronchial ultrasound-guided transbronchial forceps biopsy that could be a prerequisite for severe complications. A rupture of the steering band precluded closure of the forceps jaws opened in the subcarinal lymph node. A solution to the problem is presented, together with other procedure-related complications reported in the literature. The report emphasizes that a dysfunction of the forceps steering band can result in severe complications when it occurs during transbronchial sampling of mediastinal lesions. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. High-frequency ultrasound imaging for breast cancer biopsy guidance

    PubMed Central

    Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.

    2015-01-01

    Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167

  9. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    PubMed

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  10. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    PubMed

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    PubMed

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  12. Pathological fracture of the patella due to an atypical located aneurysmal bone cyst: verification by means of ultrasound-guided biopsy.

    PubMed

    Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander

    2016-03-01

    We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.

  13. Advantages of caudal block over intrarectal local anesthesia plus periprostatic nerve block for transrectal ultrasound guided prostate biopsy

    PubMed Central

    Wang, Na; Fu, Yaowen; Ma, Haichun; Wang, Jinguo; Gao, Yang

    2016-01-01

    Objective: To compare caudal block with intrarectal local anesthesia plus periprostatic nerve block for transrectal ultrasound guided prostate biopsy. Methods: One hundred and ninety patients scheduled for transrectal ultrasound guided prostate biopsy were randomized equally into Group-A who received caudal block (20 ml 1.2% lidocaine) and Group-B who received intrarectal local anesthesia (0.3% oxybuprocaine cream) plus periprostatic nerve block (10 ml 1% lidocaine plus 0.5% ropivacaine) before biopsy. During and after the procedure, the patients rated the level of pain/discomfort at various time points. Complications during the whole study period and the patient overall satisfaction were also evaluated. Results: More pain and discomfort was detected during periprostatic nerve block than during caudal block. Pain and discomfort was significantly lower during prostate biopsy and during the manipulation of the probe in the rectum in Group-A than in Group-B. No significant differences were detected in the pain intensity after biopsy and side effects between the two groups. Conclusions: Caudal block provides better anesthesia than periprostatic nerve block plus intrarectal local anesthesia for TRUS guided prostate biopsy without an increase of side effects. PMID:27648052

  14. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca

    2002-08-15

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yieldedmore » no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)« less

  15. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    PubMed

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  16. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  17. Ultrasound-Guided Liver Biopsy With Gelatin Sponge Pledget Tract Embolization in Infants Weighing Less Than 10 kg.

    PubMed

    Lungren, Matthew P; Lindquester, Will S; Seidel, Frank Glen; Kothary, Nishita; Monroe, Eric J; Shivaram, Giri; Gill, Anne E; Hawkins, Matthew C

    2016-12-01

    The aim of the study was to describe and assess the technical success and safety of ultrasound-guided liver biopsy with gelatin sponge pledget tract embolization technique in infants <10 kg across 3 tertiary pediatric hospitals. There were 67 pediatric patients weighing <10 kg (36 boys; 31 girls; average age 202 days; average weight 6 kg, range 1.5-9.9 kg) referred for liver biopsy performed with ultrasound guidance and gelatin sponge pledget tract embolization during a 2-year period. Patient history, procedural records, and clinical follow-up documents were retrospectively reviewed. A total of 67 procedures were included. There was 100% technical success rate and all samples obtained provided adequate tissue for histological assessment. Average number of 18 G biopsy passes was 3 (range 1-6). There were no procedure-related deaths. There was 1 complication (1%) in a 5-kg infant who was readmitted 36 hours after biopsy with a fever and fully recovered after antibiotics were administered. Biliary atresia was the most common underlying diagnosis (20%), whereas others included acute rejection (16%) and biliary obstruction (7%). Ultrasound-guided percutaneous liver biopsy with gelatin sponge pledget tract embolization technique in children weighing <10 kg is safe, effective, and use of this technique may lead to a reduction in rates of adverse events reported in other pediatric series.

  18. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  19. Is periprostatic nerve block a gold standard in case of transrectal ultrasound-guided prostate biopsy?

    PubMed Central

    Kumar, Ashok; Griwan, Mahavir Singh; Singh, Santosh Kumar; Sen, Jyotsna; Pawar, D. S.

    2013-01-01

    Introduction: Controversy exists over the pain during prostate biopsy. Periprostatic nerve block (PNB) is a gold standard anesthetic technique during transrectal ultrasound (TRUS)-guided prostate biopsy. Recent studies showed that PNB alone is insufficient as analgesic. We compared the efficacy of tramadol and intraprostatic nerve block (INB) in addition to PNB. Materials and Methods: We conducted a prospective double blinded placebo controlled study at our institute in 150 consecutive patients. Patients were randomized into three groups. Group A received PNB with INB with 1% lignocaine. Group B received oral tramadol with PNB. Group C patients were administered PNB only with 1% lignocaine. Patients were asked to grade the pain level using 11 point linear visual analog scale (VAS) at the time of ultrasound probe insertion, at time of anesthesia, during biopsy, and 30 min after biopsy. Results: The study groups were comparable in demographic profile, prostate-specific antigen (PSA) levels, and prostate size. Group A recorded the minimum mean pain score of 2.66 during prostate biopsy which was significantly lower than group 3 (P < 0.001). Group B recorded significantly lower pain score at time of probe insertion and at anesthetic needle insertion than other two groups. Conclusions: PNB provides better pain control in TRUS-guided prostate biopsy but still there is need of additional analgesic in the form of tramadol or INB. Tramadol has advantage of oral intake and analgesic effect at time of probe insertion and at nerve block. Both tramadol and INB may be used in combination along with PNB. PMID:24049376

  20. Ultrasound-Guided Transcutaneous Needle Biopsy of the Base of the Tongue and Floor of the Mouth From a Submental Approach.

    PubMed

    Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M

    2016-05-01

    Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.

  1. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    PubMed

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  2. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  3. Subjective ultrasound assessment, the ADNEX model and ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer.

    PubMed

    Epstein, E; Van Calster, B; Timmerman, D; Nikman, S

    2016-01-01

    To compare subjective ultrasound assessment and the ADNEX model with ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer. This was a prospective study including 143 consecutive women with disseminated malignancy of unknown primary origin, with a pelvic tumor/carcinosis. Women underwent either transvaginal or transrectal ultrasound as well as transabdominal ultrasound examination followed by tru-cut biopsy. The ultrasound examiner assessed tumor morphology, spread in the pelvis and abdomen, and predicted tumor origin as primary ovarian or metastatic using both subjective assessment and the ADNEX model. Histology from tru-cut biopsy served as the gold standard for assessment of diagnostic accuracy. Biopsy adequacy and the complication rate were assessed. Tru-cut biopsy was performed transvaginally in 131/143 (92%) women. Two women needed inpatient care (one had abdominal wall hematoma, and one infection). Biopsy resulted in a conclusive diagnosis in 126/143 (88%) women, amongst whom cytoreductive surgery was performed in 30/126 confirming the diagnosis in all cases. Non-ovarian metastatic cancer was found in 37/126 (29%) women and primary ovarian cancer in 89/126 (71%) women. Subjective ultrasound evaluation had a sensitivity of 82% (73/89) and a specificity of 70% (26/37) in predicting primary ovarian cancer. The ADNEX model had an area under the receiver-operating characteristics curve of 0.891 (95% CI, 0.794-0.946) (in women with an ovarian lesion, n = 104). Tumor origin was associated with age, CA 125, previous neoplasia, presence of omental cake and tumor mobility. Subjective ultrasound assessment and the ADNEX model can both be used to predict whether a pelvic tumor is metastatic and of non-ovarian origin, indicating the need for tru-cut biopsy, which is associated with very few complications and will provide a conclusive diagnosis in nine out of 10 women. Copyright © 2015 ISUOG

  4. Prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy: A prospective multicenter study.

    PubMed

    Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon

    2018-03-01

    To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.

  5. [Real-time three-dimensional (4D) ultrasound-guided prostatic biopsies on a phantom. Comparative study versus 2D guidance].

    PubMed

    Long, Jean-Alexandre; Daanen, Vincent; Moreau-Gaudry, Alexandre; Troccaz, Jocelyne; Rambeaud, Jean-Jacques; Descotes, Jean-Luc

    2007-11-01

    The objective of this study was to determine the added value of real-time three-dimensional (4D) ultrasound guidance of prostatic biopsies on a prostate phantom in terms of the precision of guidance and distribution. A prostate phantom was constructed. A real-time 3D ultrasonograph connected to a transrectal 5.9 MHz volumic transducer was used. Fourteen operators performed 336 biopsies with 2D guidance then 4D guidance according to a 12-biopsy protocol. Biopsy tracts were modelled by segmentation in a 3D ultrasound volume. Specific software allowed visualization of biopsy tracts in the reference prostate and evaluated the zone biopsied. A comparative study was performed to determine the added value of 4D guidance compared to 2D guidance by evaluating the precision of entry points and target points. The distribution was evaluated by measuring the volume investigated and by a redundancy ratio of the biopsy points. The precision of the biopsy protocol was significantly improved by 4D guidance (p = 0.037). No increase of the biopsy volume and no improvement of the distribution of biopsies were observed with 4D compared to 2D guidance. The real-time 3D ultrasound-guided prostate biopsy technique on a phantom model appears to improve the precision and reproducibility of a biopsy protocol, but the distribution of biopsies does not appear to be improved.

  6. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  7. The Rectal Administration of Lignocaine Gel and Periprostatic Lignocaine Infiltration During Transrectal Ultrasound-Guided Prostate Biopsy Provides Effective Analgesia

    PubMed Central

    Siddiqui, EJ; Ali, S; Koneru, S

    2006-01-01

    INTRODUCTION Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or exclude prostate cancer. This procedure can be associated with significant discomfort, both on insertion of the ultrasound probe as well as on taking the biopsy. We evaluated a new technique for pain relief during TRUS biopsy. PATIENTS AND METHODS In Group 1 (n = 60), the biopsies were taken without any analgesia. In Group 2 (n = 60), 11 ml of Instillagel (2% lignocaine) was administered rectally prior to probe insertion and 5 ml of 1% lignocaine periprostatic injection was administered before taking the biopsy. The discomfort encountered during the procedure was graded by the patient on a scale ranging from no discomfort to mild, moderate and severe pain. RESULTS In Group 2, there was a marked reduction in the pain experienced during the procedure. The Chi-squared test for trend showed a significant association between the rectal administration of local anaesthetic gel and reduction in pain on probe insertion (P = 0.0001). There was also a significant association between the use of periprostatic lignocaine injection and reduction in pain on taking the biopsy (P < 0.0001). CONCLUSIONS The use of lignocaine gel prior to probe insertion and periprostatic infiltration of lignocaine before taking the needle biopsy significantly reduces the pain experienced by the patient during TRUS-guided prostate biopsy. PMID:16551424

  8. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    PubMed

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  9. Combined ultrasound-guided cutting-needle biopsy and standard pleural biopsy for diagnosis of malignant pleural effusions.

    PubMed

    Wang, Jinlin; Zhou, Xinghua; Xie, Xiaohong; Tang, Qing; Shen, Panxiao; Zeng, Yunxiang

    2016-11-17

    The most efficient approach to diagnose malignant pleural effusions (MPEs) is still controversial and uncertain. This study aimed to evaluate the utility of a combined approach using ultrasound (US)-guided cutting-needle biopsy (CNB) and standard pleural biopsy (SPB) for diagnosing MPE. Pleural effusions were collected from 172 patients for biochemical and microbiological analyses. US-guided CNB and SPB were performed in the same operation sequentially to obtain specimens for histological analysis. US-guided CNB and SPB procedures provided adequate material for histological analysis in 90.7 and 93.0% of cases, respectively, while a combination of the 2 techniques was in 96.5% of cases. The sensitivity, specificity, positive-predictive value (PPV), negative-predictive value (NPV) and diagnostic accuracy of US-guided CNB versus SPB were: 51.2 vs 63.4%, 100 vs 100%, 100 vs 100%, 64.9 vs 72.2% and 74.4 vs 81.3%, respectively. When CNB was combined with SPB, the corresponding values were 88.6, 100, 100, 88.6 and 93.9%, respectively. Whereas sensitivity, NPV and diagnostic accuracy were not significantly different between CNB and SPB, the combination of CNB and SPB significantly improved the sensitivity, NPV and diagnostic accuracy versus each technique alone (p < 0.05). Significant pain (eight patients), moderate haemoptysis (two patients) and chest wall haematomas (two patients) were observed following CNB, while syncope (four patients) and a slight pneumothorax (four patients) were observed following SPB. Use of a combination of US-guided CNB and SPB afforded a high sensitivity to diagnose MPEs, it is a convenient and safe approach.

  10. Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students

    ERIC Educational Resources Information Center

    de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina

    2018-01-01

    The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…

  11. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination.

    PubMed

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-05-01

    The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=-2.487 (-2.040 to -0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=-2.272 (-0.028 to -0.002). ANOVA reported significant differences across years of experience (0-1, 1-2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required.

  12. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination

    PubMed Central

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-01-01

    Objectives The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Methods Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Results Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=−2.487 (−2.040 to −0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=−2.272 (−0.028 to −0.002). ANOVA reported significant differences across years of experience (0–1, 1–2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. Conclusion It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required. PMID:21304005

  13. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia

    2012-08-15

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to

  14. Accuracy and effectiveness of ultrasound-guided core-needle biopsy in the diagnosis of focal lesions in the salivary glands.

    PubMed

    Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio

    2018-01-31

    To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.

  15. Ethnicity influences pain after ultrasound-guided percutaneous liver biopsy.

    PubMed

    Mahadeva, Sanjiv; Mahfudz, Anis S; Vijayananthan, Anushya

    2015-12-01

    The influence of ethnicity on pain complicating ultrasound-guided percutaneous liver biopsy (US-guided PLB) and its clinical impact has not been reported to date. Consecutive adults from a multiethnic background, undergoing an US-guided PLB, were independently assessed for pain up to 6 h after the procedure. Clinical and demographic parameters were analysed to determine independent predictors of significant pain after PLB. Willingness to undergo a repeat procedure was assessed 1 week after PLB. Data from 203 patients (median age 50 years; 43.9% female; ethnicity: Malay 41.5%, Chinese 40%, Indian 18%; median BMI 27.7 kg/m; median waist circumference 92.0 cm) were analysed. Pain after US-guided PLB was experienced in 133 (61.1%) patients, with severity grades as follows: none, n=81 (39.9%); mild, n=56 (27.6%); moderate, n=51 (25.1%); and severe, n=15 (7.4%). Analgesia requirements correlated well with severity of pain. Independent predictors of significant pain after PLB (moderate and severe categories) in patients included age less than 50 years [odds ratio (OR) 3.0], female sex (OR 3.7), Indian ethnicity (OR 2.9) and Malay ethnicity (OR 2.7), but not number of needle passes, BMI and educational levels. Patients who experienced moderate/severe pain were less willing to undergo a repeat PLB compared with those who experienced mild/no pain (60.9 vs. 82.8%, P=0.001). Ethnicity has an important role in the development of pain after US-guided PLB. This has a significant impact on willingness to repeat the procedure.

  16. Positional calibration of an ultrasound image-guided robotic breast biopsy system.

    PubMed

    Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob

    2012-03-01

    Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting

  17. Acute bacterial prostatitis after transrectal ultrasound-guided prostate biopsy: epidemiological, bacteria and treatment patterns from a 4-year prospective study.

    PubMed

    Campeggi, Alexandre; Ouzaid, Idir; Xylinas, Evanguelos; Lesprit, Philippe; Hoznek, Andras; Vordos, Dimitri; Abbou, Claude-Clément; Salomon, Laurent; de la Taille, Alexandre

    2014-02-01

    To evaluate the incidence, and clinical and bacterial features of iatrogenic prostatitis within 1 month after transrectal ultrasound-guided biopsy for detection of prostate cancer. From January 2006 to December 2009, 3000 patients underwent a 21-core transrectal ultrasound-guided prostate biopsy at Henri Mondor Hospital (Créteil, France) and were prospectively followed. All patients had a fluoroquinolone antimicrobial prophylaxis for 7 days. The primary study end-point was to evaluate the incidence of iatrogenic acute prostatitis within 1 month after the biopsy. The secondary end-point was to analyze the clinical and the bacterial features of the prostatitis. Overall, 20 patients of the entire study population (0.67%) had an acute bacterial prostatitis within 2.90 ± 1.77 days (range 1-7 days) after the transrectal ultrasound-guided biopsy. The groups of patients with (n = 20) and without (n = 2980) infection were similar in terms of age, prostate-specific antigen level and prostate volume. Escherichia coli was the only isolated bacteria. The subsequent tests for antibiotic susceptibility showed a 95% resistance for fluroquinolone and amoxicillin. Resistance to amoxiclav, trimethoprim-sulfamethoxazole, third generation cephalosporin and amikacin was 70%, 70%, 25% and 5% respectively. No resistance to imipenem was reported. They were all admitted for treatment without the need of intensive care unit referral. Complete recovery was achieved after 21.4 ± 7 days of antibiotic treatment. A fluroquinolone-based regimen still represents an appropriate prophylaxis protocol to minimize the risk of acute prostatitis secondary to prostate biopsy. Patients should be provided the appropriate care soon after the onset of the symptoms. An intravenous third generation cephalosporin or imipenem-based therapy seem to provide satisfying results. © 2013 The Japanese Urological Association.

  18. Biopsy of Liver Target Lesions under Contrast-Enhanced Ultrasound Guidance - A Multi-Center Study.

    PubMed

    Francica, Giampiero; Meloni, Maria Franca; de Sio, Ilario; Terracciano, Fulvia; Caturelli, Eugenio; Riccardi, Laura; Roselli, Paola; Iadevaia, Maddalena Diana; Scaglione, Mariano; Lenna, Giovanni; Chiang, Jason; Pompili, Maurizio

    2017-12-12

    Purpose  To retrospectively characterize the prevalence and impact of contrast-enhanced ultrasound (CEUS) as a guidance technique for the biopsy of liver target lesions (LTLs) at six interventional ultrasound centers. Materials and Methods  The six participating centers retrospectively selected all patients in whom biopsy needles were positioned in LTLs during CEUS. The prevalence of CEUS-guided biopsies at each center between 2005 and 2016, contrast agent consumption, procedure indications, diagnostic yield and complications were assessed. Informed consent was obtained for all patients. Results  CEUS-guided biopsy of LTLs was carried out in 103 patients (68 M/35 F, median age: 69 yrs) with 103 liver target lesions (median size: 20 mm) using cutting needles (18 - 20 g) in 94 cases (91.2 %). CEUS-guided biopsy represented 2.6 % (range: 0.8 - 7.7 %) of 3818 biopsies on LTLs carried out at the participating centers. Indications to CEUS-guided biopsy were: a target lesion not visible on non-enhanced US (27.2 %), improvement of conspicuity of the target (33 %), choice of non-necrotic area inside the target (39.8 %). 26 patients (25.2 %) had a previously non-diagnostic cyto-histological exam. The diagnostic accuracy of the technique was 99 %. No major complications followed infusion of contrast agent or biopsy performance. Conclusion  The indications for CEUS-guided biopsy for LTLs are limited, but CEUS can be useful in challenging clinical scenarios, e. g. poorly visualized or invisible lesions or sampling of non-necrotic areas in the target lesions. There is also a potential advantage in using CEUS to guide repeat biopsies after unsuccessful sampling performed using the standard ultrasound technique. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Ultrasound-guided urinary bladder biopsy through a urinary catheter in a bitch.

    PubMed

    Lopez, Julio; Norman, Brian C

    2014-01-01

    A 34.4 kg 5 yr old spayed female mixed-breed dog was presented for evaluation of a urinary bladder mass. The dog had a recent onset of hematuria and stranguria but otherwise appeared to be healthy. Abdominal ultrasound revealed a mass in the urinary bladder. The dog was sedated and a 10-French rubber catheter that had the blunt end removed was passed from the urethra to the urinary bladder. Using ultrasound guidance, ellipsoid cup biopsy forceps were advanced through the rubber catheter to the urinary bladder mass and biopsies were successfully obtained. The dog was discharged from the hospital a few hours after the procedure. Histopathology of the mass was consistent with polypoid cystitis. Follow-up surgical removal of the polyp was uneventful, and histopathology confirmed the presurgical biopsy diagnosis. Procurement of urinary bladder biopsies through a urinary catheter with ultrasound guidance was used as a minimally invasive alternative to either cystoscopy or surgery in a bitch. Use of this technique achieved a diagnosis without the need for specialized endoscopic equipment, anesthesia, or surgery.

  20. Stiffness at shear-wave elastography and patient presentation predicts upgrade at surgery following an ultrasound-guided core biopsy diagnosis of ductal carcinoma in situ.

    PubMed

    Evans, A; Purdie, C A; Jordan, L; Macaskill, E J; Flynn, J; Vinnicombe, S

    2016-11-01

    The aim of this study is to establish predictors of invasion in lesions yielding an ultrasound-guided biopsy diagnosis of ductal carcinoma in situ (DCIS). Patients subjected to ultrasound-guided core biopsy yielding DCIS were studied. At shear-wave elastography (SWE) a threshold of 50 kPa was used for mean elasticity (Emean) to dichotomise the elasticity data between invasive and non-invasive masses. Data recorded included the mammographic and ultrasound features, the referral source, and grade of DCIS in the biopsy. The chi-square test was used to detect statistical significance. Of 57 lesions, 24 (42%) had invasion at excision. Symptomatic patients and patients with stiff lesions were more likely to have invasion than patients presenting through screening and with soft lesions (58% [14 of 24] versus 30% [10 of 33], p=0.03) and (51% [20 of 39] versus 22% [4 of 18], p=0.04). No other factors showed a relationship with invasion. Combining the two predictors of invasion improved risk stratification with symptomatic and stiff lesions having a risk of invasion of 67% (12 of 18) and soft lesions presenting at screening having only a 17% (2 of 12) risk of invasion (p=0.02). Stiffness on SWE and the referral source of the patient are predictors of occult invasion in women with an ultrasound-guided core biopsy diagnosis of DCIS. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Rapid diagnosis of liver cancer by ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Huber, K; Heuhold, N

    1987-01-01

    Because of the relatively favorable prognosis to the patient with early detected hepatocarcinoma followed by surgical treatment if resection is possible, it is important to differentiate quickly between primary and secondary liver cancer. Ultrasound-guided percutaneous fine needle aspiration biopsy (US-FNAB) was used as a first diagnostic measure in patients with sonographic evidence of liver tumors. Biopsies were done under sonographic control and antiseptic conditions from the center and the border zone of solid tumors of the liver, and the aspirated cell material was air dried on glass slides and Giemsa stained. The cytologic diagnosis was proved by clinical course and in most cases by surgical or autoptic histology. Cytologic evaluation lead in 15 cases to the diagnosis of definitive or suspicious malignant liver disease; the sensitivity was 93% and the specificity was 87%. One case classified as suspicious for malignancy by cytologic examination could be identified as cirrhotic nodule by further investigations. In none of the patients did we find complications from the biopsy procedure. From these data it is concluded that US-FNAB can serve as a rapid, inexpensive, safe, and highly accurate first diagnostic step in patients with solid lesions of the liver.

  2. The effect of rectal Foley catheterization on rectal bleeding rates after transrectal ultrasound-guided prostate biopsy.

    PubMed

    Kilciler, Mete; Erdemir, Fikret; Demir, Erkan; Güven, Oğuz; Avci, Ali

    2008-09-01

    To assess whether Foley catheterization of the rectum after transrectal ultrasound (TRUS)-guided prostate biopsy decreases complication rates. Between June 2000 and September 2006, 275 consecutive patients were evaluated after undergoing TRUS-guided prostate biopsy. All procedures were performed on an outpatient basis. Patients were divided into two groups. In the first group (n = 134), a Foley catheter was inserted into the rectum and inflated to 50 cm(3) after TRUS-guided biopsy. In the second group (n = 141), catheterization was performed without balloon placement. Rectal bleeding, hematuria, hematospermia, infection, and acute urinary retention rates were compared between groups. The mean ages of the patients were 63.3 years +/- 5.6 and 62.1 years +/- 7.2 years in the Foley catheter group and control group, respectively (P = .112). Hematuria, hematospermia, infection, and rectal bleeding occurred in 31 (23.1%), 30 (22.4), nine (6.7%), and two patients (1.5%), respectively, in the Foley catheter group; and in 36 (25.5%), 36 (25.5%), 11 (7.8%), and 25 patients (17.7%), respectively, in the control group. The incidences of infection, hematuria, and hematospermia were not significantly different between groups (P > .05). In contrast, the rectal bleeding rate was significantly lower in the Foley catheter group (1.5%) than in the control group (17.7%; P = .001). Although it has no effect on other complications, TRUS-guided prostate biopsy with rectal Foley catheterization is a useful, practical method to decrease or prevent rectal bleeding.

  3. Diclofenac Suppository as a Preemptive Analgesia in Ultrasound-guided Biopsy of Prostate: Randomized Controlled Trial.

    PubMed

    Haroon, Naveed; Ather, M Hammad; Khan, Salma; Kumar, Pirkash; Salam, Basit

    2015-10-01

    To compare preprocedure Diclofenac suppository and Xylocaine gel with Xylocaine gel only in patients undergoing transrectal ultrasound (TRUS)-guided biopsy of prostate for pain. It is a randomized controlled trial conducted on patients undergoing TRUS-guided biopsy for clinical or biochemical suspicion of prostate cancer following a written informed consent and Ethics Review Committee approval. Patients were randomized into 2 groups. Group A included those patients who received Diclofenac suppository 2 hours before in combination with 10 mL of 2% Xylocaine gel 5 minutes before biopsy. Group B received Xylocaine gel only. A visual analog scale was used to measure the pain scores at the time of TRUS probe insertion, just after taking biopsy cores and 2 hours after biopsy. A total of 100 patients were recruited in the study with 50 patients each in group A and B. Mean age of group A was 69.1 ± 10 years and 67.3 ± 8.1 years for group B. The mean pain score for group A and B at the time of probe insertion was 0.08 ± 0.27 and 0.34 ± 0.63 (P = .032), immediately after taking biopsy cores was 1.46 ± 1.15 and 4.68 ± 0.77 (P = .000), and 2 hours after biopsy was 0.14 ± 0.45 vs 2.40 ± 0.81 (P = .000), respectively. The mean pain score at the time of TRUS probe insertion, immediately after taking biopsy cores, and 2 hours after biopsy is statistically significantly higher in group B. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. [Cost analysis of ultrasound-guided transrectal needle biopsy in prostatic carcinoma].

    PubMed

    Bissoli, E; Fandella, A; La Torre, E; Faggiano, L; Anselmo, G; Frasson, F

    1998-04-01

    The literature mortality and morbidity rates from prostatic carcinoma prompt to the better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. We evaluated the overall cost of transrectal ultrasound biopsy (TRUSB) of the prostate and investigated the economic impact of the procedures currently used to diagnose prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 1996. The following cost factors were evaluated: personnel, materials, maintenance-equipment depreciation, energy consumption and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide and to consider them in the wider framework of the cost effectiveness of the strategies for the early diagnosis of prostatic cancer. The overall cost of TRUSB was Itl. 249,000, obtained by adding together the costs of: personnel (Itl. 160,000); materials (Itl. 59,000); equipment maintenance and depreciation (Itl. 12,400); energy consumption (Itl. 100); hospital overheads (Itl. 17,500). The literature review points out TRUSB as a clinically invasive tool for diagnosing prostatic carcinoma whose cost-effectiveness is debated. Cadaver studies report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, are very likely to be positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the positivity of exploration and/or transrectal ultrasound findings. Despite the strict application of all these criteria and the critical assessment of the patient's general conditions, TRUSB is indicated for 16% of the male population over 50, with obvious implications. It has been recently

  5. Concordance of Gleason grading with three-dimensional ultrasound systematic biopsy and biopsy core pre-embedding.

    PubMed

    van der Aa, Anouk A M A; Mannaerts, Christophe K; van der Linden, Hans; Gayet, Maudy; Schrier, Bart Ph; Mischi, Massimo; Beerlage, Harrie P; Wijkstra, Hessel

    2018-02-01

    To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens. Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129). The impact of 3D TRUS-guidance with pre-embedding on Gleason score (GS) concordance between biopsy and RP was evaluated using the κ-coefficient. Predictors of biopsy GS 6 upgrading were assessed using logistic regression models. Gleason concordance was comparable between the two cohorts with a κ = 0.44 for the 3D cohort, compared to κ = 0.42 for the 2D cohort. 3D TRUS-guidance with pre-embedding, did not significantly affect the risk of biopsy GS 6 upgrading in univariate and multivariate analysis. 3D TRUS-guidance with biopsy core pre-embedding did not improve Gleason concordance. Improved detection techniques are needed for recognition of low-grade disease upgrading.

  6. Effectiveness of stress management in patients undergoing transrectal ultrasound-guided biopsy of the prostate.

    PubMed

    Chiu, Li-Pin; Tung, Heng-Hsin; Lin, Kuan-Chia; Lai, Yu-Wei; Chiu, Yi-Chun; Chen, Saint Shiou-Sheng; Chiu, Allen W

    2016-01-01

    To assess the utilization of stress management in relieving anxiety and pain among patients who undergo transrectal ultrasound (TRUS)-guided biopsy of the prostate. Eighty-two patients admitted to a community hospital for a TRUS biopsy of the prostate participated in this case-controlled study. They were divided into an experimental group that was provided with stress management and a control group that received only routine nursing care. Stress management included music therapy and one-on-one simulation education. Before and after the TRUS biopsy, the patients' state-anxiety inventory score, pain visual analogue scale (VAS), respiratory rate, heart rate, and blood pressure were obtained. There were no differences in baseline and disease characteristics between the two groups. The VAS in both groups increased after the TRUS biopsy, but the difference in pre- and postbiopsy VAS scores was significantly lower in the experimental group (P=0.03). Patients in both groups experienced mild anxiety before and after the biopsy, but those in the experimental group displayed a significantly greater decrease in postbiopsy state-anxiety inventory score compared to the control group (P=0.02). Stress management can alleviate anxiety and pain in patients who received a TRUS biopsy of the prostate under local anesthesia.

  7. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  8. Application of a topical vapocoolant spray decreases pain at the site of initial intradermal anaesthetic injection during ultrasound-guided breast needle biopsy.

    PubMed

    Collado-Mesa, F; Net, J M; Arheart, K; Klevos, G A; Yepes, M M

    2015-09-01

    To assess whether the application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy decreases pain at the site of the initial injection. In this institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study, 50 women aged 49.1 ± 1.6 years (mean ± standard error) were recruited and provided written informed consent. Participants served as their own controls and were blinded as to whether a topical vapocoolant spray or a placebo was used immediately prior to the initial local anaesthetic injection at two separate biopsy sites. With the exception of the application of vapocoolant or placebo, the entire ultrasound-guided procedure was performed according to a routine protocol. Participants recorded pain at initial injection site on a visual analogue scale. General linear mixed models for repeated measures analysis of variance and a 0.05 significance level were used. Application of topical vapocoolant spray was shown to significantly decrease pain at the site of initial intradermal anaesthetic injection as compared to placebo (p<0.001). Treatment effect was independent of age of the subject, race/ethnicity, operator, type of biopsy device, and histopathology result. No complications from vapocoolant spray use were reported. Application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy significantly decreases pain at the site of the initial injection and could contribute to improve the patient's overall procedural experience. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Penthrox alone versus Penthrox plus periprostatic infiltration of local analgesia for analgesia in transrectal ultrasound-guided prostate biopsy.

    PubMed

    Huang, Sean; Pepdjonovic, Lana; Konstantatos, Alex; Frydenberg, Mark; Grummet, Jeremy

    2016-03-01

    The objective of this study was to compare pain intensity in patients undergoing transrectal ultrasound (TRUS)-guided biopsy of the prostate with Penthrox alone compared with Penthrox plus periprostatic infiltration of local analgesia (PILA). Seventy-two subjects participated in this study after receiving appropriate education. Forty-two patients self-administered inhaled Penthrox (3 mL methoxyflurane) alone for analgesia (Group A), followed by 30 patients who self-administered Penthrox and received PILA with 5 mL of 2% lignocaine. All subjects had TRUS biopsy performed. Immediately after the procedure, patients were asked to rate their pain intensity using a numerical verbal rating scale from 0 to 10. Baseline characteristics of the two groups were similar. Patients in Group B reported significantly lower post TRUS biopsy median pain intensity of 2 (1-3) compared with Group A subjects who reported a median post TRUS biopsy pain intensity of 3 (2-5) (P = 0.014). A total of 72 men underwent TRUS-guided biopsy. All patients indicated they would be happy to have another TRUS-guided prostate biopsy in the future. Our study shows that Penthrox plus PILA shows promise as an efficacious and easily tolerated analgesic technique for outpatient TRUS biopsy, keeping resource use to a minimum. Planning for a multi-centre, double-blind randomized control trial comparing Penthrox plus PILA with PILA alone is presently underway. © 2015 Royal Australasian College of Surgeons.

  10. A Single Center Evaluation of the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging against Transperineal Prostate Mapping Biopsy: An Analysis of Men with Benign Histology and Insignificant Cancer following Transrectal Ultrasound Biopsy.

    PubMed

    Pal, Raj P; Ahmad, Ros; Trecartan, Shaun; Voss, James; Ahmed, Shaista; Bazo, Alvaro; Lloyd, Jon; Walton, Thomas J

    2018-03-01

    In this study we evaluated the diagnostic performance of transrectal ultrasound guided biopsy and multiparametric magnetic resonance imaging to detect prostate cancer against transperineal prostate mapping biopsy as the reference test. Transrectal ultrasound guided biopsy, multiparametric magnetic resonance imaging and transperineal prostate mapping biopsy were performed in 426 patients between April 2012 and January 2016. Patients initially underwent systematic 12 core transrectal ultrasound guided biopsy followed 3 months later by 1.5 Tesla, high resolution T2, diffusion-weighted, dynamic contrast enhanced multiparametric magnetic resonance imaging. Two specialist uroradiologists blinded to the results of transperineal prostate mapping biopsy allocated a PI-RADS™ (Prostate Imaging-Reporting and Data System) score to each multiparametric magnetic resonance imaging study. Transperineal prostate mapping biopsy with 5 mm interval sampling, which was performed within 6 months of multiparametric magnetic resonance imaging, served as the reference test. Transrectal ultrasound guided biopsy identified 247 of 426 patients with prostate cancer and 179 of 426 with benign histology. Transperineal prostate mapping biopsy detected prostate cancer in 321 of 426 patients. On transperineal prostate mapping biopsy 94 of 179 patients with benign transrectal ultrasound guided biopsy had prostate cancer and 95 of 247 with prostate cancer on transrectal ultrasound guided biopsy were identified with cancer of higher grade. Using a multiparametric magnetic resonance imaging PI-RADS score of 3 or greater to detect significant prostate cancer, defined as any core containing Gleason 4 + 3 or greater prostate cancer on transperineal prostate mapping biopsy, the ROC AUC was 0.754 (95% CI 0.677-0.819) with 87.0% sensitivity (95% CI 77.3-97.0), 55.3% specificity (95% CI 50.2-60.4) and 97.1% negative predictive value (95% CI 94.8-99.4). Multiparametric magnetic resonance imaging is a more

  11. Value of endoscopic ultrasound guided fine needle aspiration biopsy in the diagnosis of solid pancreatic masses

    PubMed Central

    Voss, M; Hammel, P; Molas, G; Palazzo, L; Dancour, A; O'Toole, D; Terris, B; Degott, C; Bernades, P; Ruszniewski, P

    2000-01-01

    AIM—To assess the feasibility and diagnostic accuracy of endoscopic ultrasound guided fine needle biopsy (EUS-FNAB) in patients with solid pancreatic masses.
METHODS—Ninety nine consecutive patients with pancreatic masses were studied. Histological findings obtained by EUS-FNAB were compared with the final diagnosis assessed by surgery, biopsy of other tumour site or at postmortem examination, or by using a combination of clinical course, imaging features, and tumour markers.
RESULTS—EUS-FNAB was feasible in 90 patients (adenocarcinomas, n = 59; neuroendocrine tumours, n = 15; various neoplasms, n = 6; pancreatitis, n = 10), and analysable material was obtained in 73. Tumour size (⩾ or < 25 mm in diameter) did not influence the ability to obtain informative biopsy samples. Diagnostic accuracy was 74.4% (adenocarcinomas, 81.4%; neuroendocrine tumours, 46.7%; other lesions, 75%; p<0.02). Overall, the diagnostic yield in all 99 patients was 68%. Successful biopsies were performed in six patients with portal hypertension. Minor complications (moderate bleeding or pain) occurred in 5% of cases.
CONCLUSIONS—EUS-FNAB is a useful and safe method for the investigation of pancreatic masses, with a high feasibility rate even when lesions are small. Overall diagnostic accuracy of EUS-FNAB seems to depend on the tumour type.


Keywords: pancreas; tumour; endoscopic ultrasound; fine needle aspiration biopsy PMID:10644320

  12. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    PubMed Central

    Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton

    2016-01-01

    Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003

  13. Ultrasound assessment of endometrial cavity in perimenopausal women on oral progesterone for abnormal uterine bleeding: comparison of diagnostic accuracy of imaging with hysteroscopy-guided biopsy.

    PubMed

    Dasgupta, Subhankar; Dasgupta, Shyamal; Sharma, Partha Pratim; Mukherjee, Amitabha; Ghosh, Tarun Kumar

    2011-11-01

    To investigate the effect of oral progesterone on the accuracy of imaging studies performed to detect endometrial pathology in comparison to hysteroscopy-guided biopsy in perimenopausal women on progesterone treatment for abnormal uterine bleeding. The study population comprised of women aged 40-55 years with complaints of abnormal uterine bleeding who were also undergoing oral progesterone therapy. Women with a uterus ≥ 12 weeks' gestation size, previous abnormal endometrial biopsy, cervical lesion on speculum examination, abnormal Pap smear, active pelvic infection, adnexal mass on clinical examination or during ultrasound scan and a positive pregnancy test were excluded. A transvaginal ultrasound followed by saline infusion sonography were done. On the following day, a hysteroscopy followed by a guided biopsy of the endometrium or any endometrial lesion was performed. Comparison between the results of the imaging study with the hysteroscopy and guided biopsy was done. The final analysis included 83 patients. For detection of overall pathology, polyp and fibroid transvaginal ultrasound had a positive likelihood ratio of 1.65, 5.45 and 5.4, respectively, and a negative likelihood ratio of 0.47, 0.6 and 0.43, respectively. For detection of overall pathology, polyp and fibroid saline infusion sonography had a positive likelihood ratio of 4.4, 5.35 and 11.8, respectively, and a negative likelihood ratio of 0.3, 0.2 and 0.15, respectively. In perimenopausal women on oral progesterone therapy for abnormal uterine bleeding, imaging studies cannot be considered as an accurate method for diagnosing endometrial pathology when compared to hysteroscopy and guided biopsy. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.

  14. Ultrasound-Guided Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  15. Role of information in preparing men for transrectal ultrasound guided prostate biopsy: a qualitative study embedded in the ProtecT trial.

    PubMed

    Wade, Julia; Rosario, Derek J; Howson, Joanne; Avery, Kerry N L; Salter, C Elizabeth; Goodwin, M Louise; Blazeby, Jane M; Lane, J Athene; Metcalfe, Chris; Neal, David E; Hamdy, Freddie C; Donovan, Jenny L

    2015-02-28

    The histological diagnosis of prostate cancer requires a prostate needle biopsy. Little is known about the relationship between information provided to prepare men for transrectal ultrasound guided biopsy (TRUS-Bx) and how men experience biopsy. The objectives were a) to understand men's experiences of biopsy as compared to their expectations; and b) to propose current evidence-based information for men undergoing TRUS-Bx. Between February 2006 and May 2008, 1,147 men undergoing a standardised 10-core transrectal ultrasound guided biopsy protocol under antibiotic cover following a PSA 3.0-19.9 ng/ml in the Prostate Testing for Cancer and Treatment (ProtecT) trial, completed questionnaires about biopsy symptoms. In this embedded qualitative study, in-depth interviews were undertaken with 85 men (mean age 63.6 yrs, mean PSA 4.5 ng/ml) to explore men's experiences of prostate biopsy and how the experience might be improved. Interview data were analysed thematically using qualitative research methods. Findings from the qualitative study were used to guide selection of key findings from the questionnaire study in developing a patient information leaflet preparing men for biopsy. Although most men tolerated TRUS-Bx, a quarter reported problematic side-effects and anxiety. Side effects were perceived as problematic and anxiety arose most commonly when experiences deviated from information provided. Men who were unprepared for elements of TRUS-Bx procedure or its sequelae responded by contacting health professionals for reassurance and voiced frustration that pre-biopsy information had understated the possible severity or duration of pain/discomfort and bleeding. Findings from questionnaire and interview data were combined to propose a comprehensive, evidence-based patient information leaflet for TRUS-Bx. Men reported anxiety associated with TRUS-Bx or its side-effects most commonly if they felt inadequately prepared for the procedure. Data from this qualitative study and

  16. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.

    PubMed

    Gillies, Derek J; Gardi, Lori; De Silva, Tharindu; Zhao, Shuang-Ren; Fenster, Aaron

    2017-09-01

    During image-guided prostate biopsy, needles are targeted at tissues that are suspicious of cancer to obtain specimen for histological examination. Unfortunately, patient motion causes targeting errors when using an MR-transrectal ultrasound (TRUS) fusion approach to augment the conventional biopsy procedure. This study aims to develop an automatic motion correction algorithm approaching the frame rate of an ultrasound system to be used in fusion-based prostate biopsy systems. Two modes of operation have been investigated for the clinical implementation of the algorithm: motion compensation using a single user initiated correction performed prior to biopsy, and real-time continuous motion compensation performed automatically as a background process. Retrospective 2D and 3D TRUS patient images acquired prior to biopsy gun firing were registered using an intensity-based algorithm utilizing normalized cross-correlation and Powell's method for optimization. 2D and 3D images were downsampled and cropped to estimate the optimal amount of image information that would perform registrations quickly and accurately. The optimal search order during optimization was also analyzed to avoid local optima in the search space. Error in the algorithm was computed using target registration errors (TREs) from manually identified homologous fiducials in a clinical patient dataset. The algorithm was evaluated for real-time performance using the two different modes of clinical implementations by way of user initiated and continuous motion compensation methods on a tissue mimicking prostate phantom. After implementation in a TRUS-guided system with an image downsampling factor of 4, the proposed approach resulted in a mean ± std TRE and computation time of 1.6 ± 0.6 mm and 57 ± 20 ms respectively. The user initiated mode performed registrations with in-plane, out-of-plane, and roll motions computation times of 108 ± 38 ms, 60 ± 23 ms, and 89 ± 27 ms, respectively, and corresponding

  17. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    PubMed

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  18. Percutaneous ultrasound-guided renal biopsy in supine antero-lateral position: a new approach for obese and non-obese patients.

    PubMed

    Gesualdo, Loreto; Cormio, Luigi; Stallone, Giovanni; Infante, Barbara; Di Palma, Anna Maria; Delli Carri, Paolo; Cignarelli, Mauro; Lamacchia, Olga; Iannaccone, Salvatore; Di Paolo, Salvatore; Morrone, Luigi; Aucella, Filippo; Carrieri, Giuseppe

    2008-03-01

    Percutaneous ultrasound (US)-guided renal biopsy is the gold standard in the evaluation of renal diseases, but some patients, such as the obese, may not be eligible for this procedure. Aim of this study was to determine the feasibility, efficacy and safety of US-guided percutaneous renal biopsy in supine antero-lateral position (SALP) in high-risk patients (BMI > 30 and/or respiratory difficulty), as well as to compare the overall outcome of SALP with that of traditional prone position (PP) in low-risk patients (BMI < or = 30/no respiratory difficulty). One hundred and ten consecutive patients scheduled for native kidney biopsy were recruited. Ninety low-risk patients were randomized following a permuted block randomization list to receive either US-guided renal biopsy in PP (Group 1) or SALP (Group 2), whereas 20 high-risk patients received US-guided renal biopsy in SALP (Group 3) and were our observational cohort study. Comfort compliance and breathing difficulty in each group were evaluated by the Visual Analogue Scale (VAS). Bleeding complications were evaluated through US renal scanning. Mean operating time was 7 min. Comfort compliance and breathing difficulty were significantly better for SALP in both low- and high-risk patients; there were no significant differences in pain after biopsy among the three groups. Bleeding complications were slightly higher in Group 1. Diagnostic yield was similar in all groups. SALP is reliable, minimally invasive, easy, highly successful, timesaving and almost free from severe side-effects. A better VAS score for breathing difficulty and comfort compliance characterizes this procedure, making it particularly suitable for obese patients.

  19. A deep learning approach for real time prostate segmentation in freehand ultrasound guided biopsy.

    PubMed

    Anas, Emran Mohammad Abu; Mousavi, Parvin; Abolmaesumi, Purang

    2018-06-01

    Targeted prostate biopsy, incorporating multi-parametric magnetic resonance imaging (mp-MRI) and its registration with ultrasound, is currently the state-of-the-art in prostate cancer diagnosis. The registration process in most targeted biopsy systems today relies heavily on accurate segmentation of ultrasound images. Automatic or semi-automatic segmentation is typically performed offline prior to the start of the biopsy procedure. In this paper, we present a deep neural network based real-time prostate segmentation technique during the biopsy procedure, hence paving the way for dynamic registration of mp-MRI and ultrasound data. In addition to using convolutional networks for extracting spatial features, the proposed approach employs recurrent networks to exploit the temporal information among a series of ultrasound images. One of the key contributions in the architecture is to use residual convolution in the recurrent networks to improve optimization. We also exploit recurrent connections within and across different layers of the deep networks to maximize the utilization of the temporal information. Furthermore, we perform dense and sparse sampling of the input ultrasound sequence to make the network robust to ultrasound artifacts. Our architecture is trained on 2,238 labeled transrectal ultrasound images, with an additional 637 and 1,017 unseen images used for validation and testing, respectively. We obtain a mean Dice similarity coefficient of 93%, a mean surface distance error of 1.10 mm and a mean Hausdorff distance error of 3.0 mm. A comparison of the reported results with those of a state-of-the-art technique indicates statistically significant improvement achieved by the proposed approach. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Initial Experience with a Wireless Ultrasound-Guided Vacuum-Assisted Breast Biopsy Device

    PubMed Central

    Choi, E-Ryung; Han, Boo-Kyung; Ko, Eun Sook; Ko, Eun Young; Choi, Ji Soo; Cho, Eun Yoon; Nam, Seok Jin

    2015-01-01

    Objective To determine the imaging characteristic of frequent target lesions of wireless ultrasound (US)-guided, vacuum-assisted breast biopsy (Wi-UVAB) and to evaluate diagnostic yield, accuracy and complication of the device in indeterminate breast lesions. Materials and Methods From March 2013 to October 2014, 114 women (age range, 29–76 years; mean age, 50.0 years) underwent Wi-UVAB using a 13-gauge needle (Mammotome Elite®; Devicor Medical Products, Cincinnati, OH, USA). In 103 lesions of 96 women with surgical (n = 81) or follow-up (n = 22) data, complications, biopsy procedure, imaging findings of biopsy targets and histologic results were reviewed. Results Mean number of biopsy cores was 10 (range 4–25). Nine patients developed moderate bleeding. All lesions were suspicious on US, and included non-mass lesions (67.0%) and mass lesions (33.0%). Visible calcifications on US were evident in 57.3% of the target lesions. Most of the lesions (93.2%) were nonpalpable. Sixty-six (64.1%) were malignant [ductal carcinoma in situ (DCIS) rate, 61%] and 12 were high-risk lesions (11.7%). Histologic underestimation was identified in 11 of 40 (27.5%). DCIS cases and in 3 of 9 (33.3%) high-risk lesions necessitating surgery. There was no false-negative case. Conclusion Wi-UVAB is very handy and advantageous for US-unapparent non-mass lesions to diagnose DCIS, especially for calcification cases. Histologic underestimation is unavoidable; still, Wi-UVAB is safe and accurate to diagnose a malignancy. PMID:26630136

  1. The efficacy of duration of prophylactic antibiotics in transrectal ultrasound guided prostate biopsy.

    PubMed

    Bulut, Volkan; Şahin, Ali Feyzullah; Balaban, Yavuz; Altok, Muammer; Divrik, Rauf Taner; Zorlu, Ferruh

    2015-01-01

    We aimed to evaluate the efficacy of the duration of prophylactic antibiotic administration in patients undergoing transrectal ultrasound (TRUS) guided biopsy. A total of 367 patients undergoing a prostate biopsy between September 2007 and June 2009 was reviewed retrospectively and divided into 2 groups according to prophilaxy: oral ciprofloxacin (750 mg every 12 hours) for 3 or more days in Group-1 and single day in Group-2. Demographic characteristics of patients, symptoms, PSA values, IPSS scores, prostate sizes, pathologic results and complications were compared between the groups. The mean age of all patients was 63.92 years and the mean PSA was 13.61ng/ dL. The pre-biopsy mean IPSS score was 12.47 and mean prostate volume 52.53 mL. For 78.2% of patients the current biopsy was their first biopsy. Cancer detection rate was 24.2%. Fever was observed in 3 (1.2%) patients in Group-1 and 5 (4.0%) patients in Group-2. Local infections occurred in 2 (0.8%) and 1 (0.8%) patients respectively in Groups 1 and 2. Acute prostatitis was observed in only 1 (0.8%) patient in Group-2. None of the patients developed septicemia or other serious infection. There was no statistically significant difference in terms of fever, local infections (epididimitis, orchitis, etc.) and acute prostatitis. In a selected patient population single dose prophylaxis with ciprofloxacin can be safely administered compared to other regimens of 3 or more days. Increasing the duration of antibiotic prophylaxis does not decrease infectious complications.

  2. Comparative analysis of laparoscopic and ultrasound-guided biopsy methods for gene expression analysis in transgenic goats.

    PubMed

    Melo, C H; Sousa, F C; Batista, R I P T; Sanchez, D J D; Souza-Fabjan, J M G; Freitas, V J F; Melo, L M; Teixeira, D I A

    2015-07-31

    The present study aimed to compare laparoscopic (LP) and ultrasound-guided (US) biopsy methods to obtain either liver or splenic tissue samples for ectopic gene expression analysis in transgenic goats. Tissue samples were collected from human granulocyte colony stimulating factor (hG-CSF)-transgenic bucks and submitted to real-time PCR for the endogenous genes (Sp1, Baff, and Gapdh) and the transgene (hG-CSF). Both LP and US biopsy methods were successful in obtaining liver and splenic samples that could be analyzed by PCR (i.e., sufficient sample sizes and RNA yield were obtained). Although the number of attempts made to obtain the tissue samples was similar (P > 0.05), LP procedures took considerably longer than the US method (P = 0.03). Finally, transgene transcripts were not detected in spleen or liver samples. Thus, for the phenotypic characterization of a transgenic goat line, investigation of ectopic gene expression can be made successfully by LP or US biopsy, avoiding the traditional approach of euthanasia.

  3. Two Cases of Lethal Complications Following Ultrasound-Guided Percutaneous Fine-Needle Biopsy of the Liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drinkovic, Ivan; Brkljacic, Boris

    1996-09-15

    Two cases with lethal complications are reported among 1750 ultrasound (US)-guided percutaneous fine-needle liver biopsies performed in our department. The first patient had angiosarcoma of the liver which was not suspected after computed tomography (CT) and US studies had been performed. The other patient had hepatocellular carcinoma in advanced hepatic cirrhosis. Death was due to bleeding in both cases. Pre-procedure laboratory tests did not reveal the existence of major bleeding disorders in either case. Normal liver tissue was interposed in the needle track between the liver capsule and the lesions which were targeted.

  4. Incidence of sepsis following transrectal ultrasound guided prostate biopsy at a tertiary-care medical center in Lebanon

    PubMed Central

    Shahait, Mohammed; Degheili, Jad; El-Merhi, Fadi; Tamim, Hani; Nasr, Rami

    2016-01-01

    ABSTRACT Background Urosepsis is a rare but life-threatening complication following transrectal ultrasound (TRUS) guided needle prostate biopsy. Despite the technological and pharmacological improvements, the problem of bacterial urosepsis after prostate biopsy remains. A strategy for preventing urosepsis following TRUS prostate biopsy in areas with high prevalence of resistant strains or patients presenting risk factors is lacking. Objectives The aim of this study was to assess the prevalence of urosepsis, as well its predictors, following TRUS guided needle biopsy of the prostate in a tertiary care medical center in Lebanon. Materials and Methods We carried out a retrospective study on all patients who underwent TRUS prostate biopsy at the American University of Beirut Medical Center between January 1, 2011 and June 31, 2013. Patients’ hospital charts were reviewed. Data collected included demographic information, pre-procedure disease specific information, as well as post-procedure information. Predictors of urosepsis following TRUS were assessed. Results In total, 265 patients were included in this study, where the prevalence of urosepsis following TRUS prostate biopsy was found to be 9.4%. The significant independent predictors of urosepsis were found to be: age with an OR=0.93 (95% CI: 0.88–1.00, p-value=0.03), and hypertension comorbidity with an OR=3.25 (95% CI: 1.19–8.85, p-value=0.02). Conclusion We found a high prevalence of urosepsis among patients who have undergone TRUS prostate biopsy, and identified two significant risk factors. The results of this study highlight the importance of implementing strategies for prevention of urosepsis following TRUS prostate biopsy. PMID:27136468

  5. Ultrasound-guided core needle biopsy of cervical lymph nodes in the diagnosis of toxoplasmosis.

    PubMed

    Cho, Woojin; Kim, Min Kyung; Sim, Jung Suk

    2017-05-01

    Our study investigates whether the histopathological features of toxoplasmic lymphadenitis (TL), specifically noncaseating microgranuloma and follicular hyperplasia, can be obtained by sonographic-guided core needle biopsy (CNB) of cervical lymph nodes. Thirty-two patients seen from June 2014 to March 2015 were positive for toxoplasma immunoglobulin M antibody. Among those patients, 21 underwent CNB of a cervical lymph node and were enrolled in this study. The pathologic findings were reviewed. Twenty-nine lymph nodes in 21 patients were sampled. Eighteen of the 21 (86%) patients had a microgranuloma without caseating necrosis or giant cells, and all 21 (100%) patients had follicular hyperplasia. The histologic findings of TL were detected by sonographic-guided CNB, which can be used as part of the first line of investigation in patients with unexplained cervical adenopathy. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:192-196, 2017. © 2016 Wiley Periodicals, Inc.

  6. The efficacy of duration of prophylactic antibiotics in transrectal ultrasound guided prostate biopsy

    PubMed Central

    Bulut, Volkan; Şahin, Ali Feyzullah; Balaban, Yavuz; Altok, Muammer; Divrik, Rauf Taner; Zorlu, Ferruh

    2015-01-01

    ABSTRACT Introduction: We aimed to evaluate the efficacy of the duration of prophylactic antibiotic administration in patients undergoing transrectal ultrasound (TRUS) guided biopsy. Material and Methods: A total of 367 patients undergoing a prostate biopsy between September 2007 and June 2009 was reviewed retrospectively and divided into 2 groups according to prophilaxy: oral ciprofloxacin (750 mg every 12 hours) for 3 or more days in Group-1 and single day in Group-2. Demographic characteristics of patients, symptoms, PSA values, IPSS scores, prostate sizes, pathologic results and complications were compared between the groups. Results: The mean age of all patients was 63.92 years and the mean PSA was 13.61ng/ dL. The pre-biopsy mean IPSS score was 12.47 and mean prostate volume 52.53 mL. For 78.2% of patients the current biopsy was their first biopsy. Cancer detection rate was 24.2%. Fever was observed in 3 (1.2%) patients in Group-1 and 5 (4.0%) patients in Group-2. Local infections occurred in 2 (0.8%) and 1 (0.8%) patients respectively in Groups 1 and 2. Acute prostatitis was observed in only 1 (0.8%) patient in Group-2. Accepted after revision: None of the patients developed septicemia or other serious infection. There was no statistically significant difference in terms of fever, local infections (epididimitis, orchitis, etc.) and acute prostatitis. Conclusions: In a selected patient population single dose prophylaxis with ciprofloxacin can be safely administered compared to other regimens of 3 or more days. Increasing the duration of antibiotic prophylaxis does not decrease infectious complications. PMID:26689515

  7. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    PubMed

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological

  8. Ultrasound - Breast

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...

  9. Use of Lymph Node Ultrasound Prior to Sentinel Lymph Node Biopsy in 384 Patients with Melanoma: A Cost-Effectiveness Analysis.

    PubMed

    Olmedo, D; Brotons-Seguí, M; Del Toro, C; González, M; Requena, C; Traves, V; Pla, A; Bolumar, I; Moreno-Ramírez, D; Nagore, E

    2017-12-01

    Locoregional lymph node ultrasound is not typically included in guidelines as part of the staging process prior to sentinel lymph node biopsy (SLNB). The objective of the present study was to make a clinical and economic analysis of lymph node ultrasound prior to SLNB. We performed a retrospective study of 384 patients with clinical stage I-II primary melanoma who underwent locorregional lymph node ultrasound (with or without ultrasound-guided biopsy) prior to SLNB between 2004 and 2015. We evaluated the reliability and cost-effectiveness of the strategy. Use of locorregional lymph node ultrasound avoided SLNB in 23 patients (6%). Ultrasound had a sensitivity of 46% and specificity of 76% for the detection of metastatic lymph nodes that were not clinically palpable. False negatives were significantly more common in patients aged over 60 years and in tumors with a thickness of less than 2mm. The staging process using SLNB and ultrasound with ultrasound-guided biopsy produced an increase of €16.30 in the unit price. Our cost-effectiveness analysis identified the staging protocol with ultrasound and SLNB as the dominant strategy, with a lower cost-effectiveness ratio than the alternative, consisting of SLNB alone (8,095.24 vs. €28,605.00). Ultrasound with ultrasound-guided biopsy for the diagnostic staging of melanoma prior to SLNB is a useful and cost-effective tool. This procedure does not substitute SLNB, though it does allow to avoid SLNB in a not insignificant proportion of patients. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    PubMed

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  11. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

  12. Biological characteristics of HCC by ultrasound-guided aspiration biopsy and its clinical application

    PubMed Central

    Lin, Li-Wu; Lin, Xue-Ying; He, Yi-Mi; Gao, Shang-Da; Lin, Xiao-Dong

    2003-01-01

    AIM: To probe the pathological biological characteristics of hepatocellular carcinoma (HCC) by the ultrasound-guided aspiration biopsy and assess the clinical application value of this method. METHODS: The biopsy and DNA analysis by flow cytometry (FCM) were taken in 46 cases with HCC nodules, including 26 cases and 20 cases with nodules ≤ 3 cm and > 3 cm in diameters respectively, and 12 cases with intrahepatic benign hyperplastic nodules. They were taken in 22 cases of 46 cases with HCC before and after the therapy. Fine-needles and automatic histological incised biopsy needles were used. The fresh biopsy tissue was produced into the single cell suspension, which was sent for DNA detection and ratio analysis of cell period. The ratio of each DNA period of cell proliferation of each group was calculated and compared with each other. The DNA aneuploid (AN) and apoptosis cell peak were observed and their percentages were calculated. RESULTS: The ratios of S and G2/M periods of DNA, which reflect cell hyperproliferation, in the group with HCC tumors > 3 cm in diameter were markedly higher than those of the group with HCC nodules ≤ 3 cm in diameter and the group with the benign hyperplastic nodules (P < 0.01 except A:B of S period, P < 0.05). The ratios of the middle group were also apparently higher than those of the latter group (P < 0.01). The ratio of DNA AN of 46 cases with HCC nodules was 34.8% (16/46). None of the cases with the intrahepatic hyperplastic nodules appeared AN. The DNA AN appeared more apparently with the growth of the tumors. The AN ratio of the group with tumors > 3 cm in diameter was 55% (11/20), markedly higher than that of the group with tumors ≤ 3 cm in diameter which was 19.2% (5/26) (P < 0.01). The FCM DNA analysis of 22 specimens of hepatic carcinoma tissue before therapy showed that the aneuploid peaks appeared in 5 cases (22.7%). The ratio of G1 period rose after therapy while the S period and G2/M ratios fell (P < 0.01). The

  13. The change in serum Thiol/Disulphide homeostasis after transrectal ultrasound guided prostate biopsy

    PubMed Central

    Tokgöz, Hüsnü; Taş, Selim; Giray, Özlem; Yalçınkaya, Soner; Tokgöz, Özlem; Koca, Cemile; Savaş, Murat; Erel, Özcan

    2017-01-01

    ABSTRACT Objectives The aim of this prospective clinical study was to investigate variations in a novel oxidative stress marker (thiol/disulphide homeostasis) in men who underwent transrectal ultrasound guided prostate biopsy (TRUSB). Materials and Methods A total of 22 men undergoing TRUSB of the prostate were enrolled in the study. Patients with abnormal digital rectal examination and/or total prostate specific antigen (PSA) over 4ng/mL underwent TRUSB with 12 cores. Serum samples were obtained before and just after the procedure to evaluate the possible changes in thiol/disulphide homeostasis. Mean age, total PSA and free PSA, prostate volume and histopathological data were also recorded. Results Mean age of the study population was 65.05±8.89 years. Significant decreases in native and total thiol levels were documented after the biopsy procedure. However, serum disulphide levels and disulphide/native thiol, disulphide/total thiol and native/total thiol ratios did not significantly change after TRUSB. No correlation was observed between oxidative parameters and total PSA and free PSA levels, prostate volume and histopathology of the prostate. However, mean patient age was significantly correlated with mean native and total thiol levels. Conclusion Significant decreases in serum native and total thiol levels related to the prostate biopsy procedure suggest that TRUSB causes acute oxidative stress in the human body. Since our trial is the first in the current literature to investigate these oxidative stress markers in urology practice, additional studies are warranted. PMID:28128906

  14. The change in serum Thiol/Disulphide homeostasis after transrectal ultrasound guided prostate biopsy.

    PubMed

    Tokgöz, Hüsnü; Taş, Selim; Giray, Özlem; Yalçınkaya, Soner; Tokgöz, Özlem; Koca, Cemile; Savaş, Murat; Erel, Özcan

    2017-01-01

    The aim of this prospective clinical study was to investigate variations in a novel oxidative stress marker (thiol/disulphide homeostasis) in men who underwent transrectal ultrasound guided prostate biopsy (TRUSB). A total of 22 men undergoing TRUSB of the prostate were enrolled in the study. Patients with abnormal digital rectal examination and/or total prostate specific antigen (PSA) over 4ng/mL underwent TRUSB with 12 cores. Serum samples were obtained before and just after the procedure to evaluate the possible changes in thiol/disulphide homeostasis. Mean age, total PSA and free PSA, prostate volume and histopathological data were also recorded. Mean age of the study population was 65.05±8.89 years. Significant decreases in native and total thiol levels were documented after the biopsy procedure. However, serum disulphide levels and disulphide/native thiol, disulphide/total thiol and native / total thiol ratios did not significantly change after TRUSB. No correlation was observed between oxidative parameters and total PSA and free PSA levels, prostate volume and histopathology of the prostate. However, mean patient age was significantly correlated with mean native and total thiol levels. Significant decreases in serum native and total thiol levels related to the prostate biopsy procedure suggest that TRUSB causes acute oxidative stress in the human body. Since our trial is the first in the current literature to investigate these oxidative stress markers in urology practice, additional studies are warranted. Copyright® by the International Brazilian Journal of Urology.

  15. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

    PubMed Central

    Cirla, A.; Rondena, M.; Bertolini, G.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512

  16. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

    PubMed

    Cirla, A; Rondena, M; Bertolini, G

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.

  17. Ultrasound-guided core biopsy in the diagnosis of lymphoma of the head and neck. A 9 year experience

    PubMed Central

    Burke, C; Thomas, R; Inglis, C; Baldwin, A; Ramesar, K; Grace, R; Howlett, D C

    2011-01-01

    Objectives This retrospective study aimed to evaluate the diagnostic utility of ultrasound-guided core biopsy (USCB) in lymphoma of the head and neck, in particular whether core biopsy can provide sufficient diagnostic information for definitive treatment. Methods All lymphomas diagnosed in the head and neck at Eastbourne General Hospital between January 2000 and June 2009 were identified. Radiology and pathology reports were reviewed and the diagnostic techniques recorded. The type of biopsy (fine needle aspiration, needle core, surgical excision biopsy) used to establish a diagnosis sufficient to allow treatment, i.e. the "index" diagnostic technique, was identified. Previous inconclusive or inadequate biopsies were noted. Pathology reports based on USCB were graded 0–3 according to diagnostic completeness and ability to provide treatment information. Results Of 691 overall cases of lymphoma diagnosed over the 9 year period, 171 different patients presented with lymphoma in the head and neck. Of these 171, 83 had USCB biopsy during diagnostic work up. 60 were regarded as grade 3 where a confident diagnosis of lymphoma was made. In seven patients, clinical management proceeded on the basis of a suggestive (grade 2) pathology report without surgical excision, and these were therefore also included as "index" biopsies. Overall therefore, 67/83 core biopsies (81%) provided adequate information to allow treatment. Surgical excision biopsy was the index modality in 104 cases. Conclusion In the majority of cases USCB is adequate for confident histopathological diagnosis avoiding the need for surgical excision biopsy in cases of suspected head and neck lymphoma. PMID:21427181

  18. Transcriptional Profiling of Synovial Macrophages Using Minimally Invasive Ultrasound-Guided Synovial Biopsies in Rheumatoid Arthritis.

    PubMed

    Mandelin, Arthur M; Homan, Philip J; Shaffer, Alexander M; Cuda, Carla M; Dominguez, Salina T; Bacalao, Emily; Carns, Mary; Hinchcliff, Monique; Lee, Jungwha; Aren, Kathleen; Thakrar, Anjali; Montgomery, Anna B; Bridges, S Louis; Bathon, Joan M; Atkinson, John P; Fox, David A; Matteson, Eric L; Buckley, Christopher D; Pitzalis, Costantino; Parks, Deborah; Hughes, Laura B; Geraldino-Pardilla, Laura; Ike, Robert; Phillips, Kristine; Wright, Kerry; Filer, Andrew; Kelly, Stephen; Ruderman, Eric M; Morgan, Vince; Abdala-Valencia, Hiam; Misharin, Alexander V; Budinger, G Scott; Bartom, Elizabeth T; Pope, Richard M; Perlman, Harris; Winter, Deborah R

    2018-06-01

    Currently, there are no reliable biomarkers for predicting therapeutic response in patients with rheumatoid arthritis (RA). The synovium may unlock critical information for determining efficacy, since a reduction in the numbers of sublining synovial macrophages remains the most reproducible biomarker. Thus, a clinically actionable method for the collection of synovial tissue, which can be analyzed using high-throughput strategies, must become a reality. This study was undertaken to assess the feasibility of utilizing synovial biopsies as a precision medicine-based approach for patients with RA. Rheumatologists at 6 US academic sites were trained in minimally invasive ultrasound-guided synovial tissue biopsy. Biopsy specimens obtained from patients with RA and synovial tissue from patients with osteoarthritis (OA) were subjected to histologic analysis, fluorescence-activated cell sorting, and RNA sequencing (RNA-seq). An optimized protocol for digesting synovial tissue was developed to generate high-quality RNA-seq libraries from isolated macrophage populations. Associations were determined between macrophage transcriptional profiles and clinical parameters in RA patients. Patients with RA reported minimal adverse effects in response to synovial biopsy. Comparable RNA quality was observed from synovial tissue and isolated macrophages between patients with RA and patients with OA. Whole tissue samples from patients with RA demonstrated a high degree of transcriptional heterogeneity. In contrast, the transcriptional profile of isolated RA synovial macrophages highlighted different subpopulations of patients and identified 6 novel transcriptional modules that were associated with disease activity and therapy. Performance of synovial tissue biopsies by rheumatologists in the US is feasible and generates high-quality samples for research. Through the use of cutting-edge technologies to analyze synovial biopsy specimens in conjunction with corresponding clinical

  19. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session

    PubMed Central

    Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.

    2014-01-01

    Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096

  20. Differences in accuracy and underestimation rates for 14- versus 16-gauge core needle biopsies in ultrasound-detectable breast lesions.

    PubMed

    Lai, Hung-Wen; Wu, Hwa-Koon; Kuo, Shou-Jen; Chen, Shou-Tung; Tseng, Hsin-Shun; Tseng, Ling-Ming; Chen, Dar-Ren

    2013-04-01

    Core needle biopsy (CNB) was widely used in the diagnosis of ultrasound-detectable breast lesions. We aimed at assessing the diagnostic performance differences between 14- and 16-gauge ultrasound-guided core biopsies. This retrospective study enrolled patients receiving CNB from January 2001 to December 2007. The results of 14- and 16-gauge breast CNBs were compared with pathology reports of open surgical biopsy (OSB). A total of 1024 paired CNB and OSB results were obtained from 1732 CNB procedures in 1630 patients.Those CNB results reached 92.9% sensitivity, 99.7% specificity, 5.96% underestimation, and 94.8% accuracy rates. There was no difference in sensitivity (p=0.17) or specificity (p=0.38) between 14- and 16-gauge needles. However, better overall accuracy (p=0.02), less underestimation (p<0.001), and lower false-negative (p=0.02) rates were found for the 14-gauge CNB. Regarding accuracy and underestimation rates, a 14-gauge needle is preferred to a 16-gauge one in ultrasound-guided biopsies. Copyright © 2012. Published by Elsevier B.V.

  1. Complications and adequacy of transplant kidney biopsies: A comparison of techniques.

    PubMed

    Plattner, Brett W; Chen, Pauline; Cross, Richard; Leavitt, Matthew A; Killen, Paul D; Heung, Michael

    2018-05-01

    Kidney biopsies are an essential tool in the diagnosis and management of kidney diseases, particularly in kidney transplant recipients. Biopsies carry a risk for serious complications and not all biopsies achieve adequate tissue. We examined the impact of kidney biopsy technique on complications and biopsy adequacy. The cohort consisted of consecutive kidney transplant patients undergoing biopsy by one of three techniques: ultrasound localization, real-time ultrasound guidance, and ultrasound-guided trocar placement. Variables of interest included patient characteristics and procedural characteristics. The primary outcome was serious complication attributable to kidney biopsy, and the secondary outcome was biopsy adequacy as defined by Banff criteria. Among 263 patients undergoing biopsy, 27 (10.3%) had a complication (14 with gross hematuria, 10 requiring blood transfusion, 3 requiring an unplanned interventional radiology procedure, 1 kidney loss; no deaths). Complications were more common among patients biopsied using ultrasound-guided trocar compared to real-time ultrasound and ultrasound localization (21.4% vs 7.9% vs 7.1%, respectively, p = 0.008). After adjusting for patient and procedure characteristics, technique was no longer significantly associated with complication. Biopsy adequacy was significantly higher when using ultrasound localization and real-time ultrasound compared to ultrasound-guided trocar (84.6% vs 86.8% vs 69.6%, p = 0.029), and this finding persisted in adjusted analysis. Kidney biopsy complications appear to be similar when using any of the three techniques examined in our study. However, ultrasound-guided trocar technique may yield lower biopsy adequacy when compared to non-trocar techniques.

  2. Multicentre evaluation of targeted and systematic biopsies using magnetic resonance and ultrasound image-fusion guided transperineal prostate biopsy in patients with a previous negative biopsy.

    PubMed

    Hansen, Nienke L; Kesch, Claudia; Barrett, Tristan; Koo, Brendan; Radtke, Jan P; Bonekamp, David; Schlemmer, Heinz-Peter; Warren, Anne Y; Wieczorek, Kathrin; Hohenfellner, Markus; Kastner, Christof; Hadaschik, Boris

    2017-11-01

    To evaluate the detection rates of targeted and systematic biopsies in magnetic resonance imaging (MRI) and ultrasound (US) image-fusion transperineal prostate biopsy for patients with previous benign transrectal biopsies in two high-volume centres. A two centre prospective outcome study of 487 patients with previous benign biopsies that underwent transperineal MRI/US fusion-guided targeted and systematic saturation biopsy from 2012 to 2015. Multiparametric MRI (mpMRI) was reported according to Prostate Imaging Reporting and Data System (PI-RADS) Version 1. Detection of Gleason score 7-10 prostate cancer on biopsy was the primary outcome. Positive (PPV) and negative (NPV) predictive values including 95% confidence intervals (95% CIs) were calculated. Detection rates of targeted and systematic biopsies were compared using McNemar's test. The median (interquartile range) PSA level was 9.0 (6.7-13.4) ng/mL. PI-RADS 3-5 mpMRI lesions were reported in 343 (70%) patients and Gleason score 7-10 prostate cancer was detected in 149 (31%). The PPV (95% CI) for detecting Gleason score 7-10 prostate cancer was 0.20 (±0.07) for PI-RADS 3, 0.32 (±0.09) for PI-RADS 4, and 0.70 (±0.08) for PI-RADS 5. The NPV (95% CI) of PI-RADS 1-2 was 0.92 (±0.04) for Gleason score 7-10 and 0.99 (±0.02) for Gleason score ≥4 + 3 cancer. Systematic biopsies alone found 125/138 (91%) Gleason score 7-10 cancers. In patients with suspicious lesions (PI-RADS 4-5) on mpMRI, systematic biopsies would not have detected 12/113 significant prostate cancers (11%), while targeted biopsies alone would have failed to diagnose 10/113 (9%). In equivocal lesions (PI-RADS 3), targeted biopsy alone would not have diagnosed 14/25 (56%) of Gleason score 7-10 cancers, whereas systematic biopsies alone would have missed 1/25 (4%). Combination with PSA density improved the area under the curve of PI-RADS from 0.822 to 0.846. In patients with high probability mpMRI lesions, the highest detection rates of Gleason

  3. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    PubMed

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  4. Gleason Score Determination with Transrectal Ultrasound-Magnetic Resonance Imaging Fusion Guided Prostate Biopsies--Are We Gaining in Accuracy?

    PubMed

    Lanz, Camille; Cornud, François; Beuvon, Frédéric; Lefèvre, Arnaud; Legmann, Paul; Zerbib, Marc; Delongchamps, Nicolas Barry

    2016-01-01

    We evaluated the accuracy of prostate magnetic resonance imaging- transrectal ultrasound targeted biopsy for Gleason score determination. We selected 125 consecutive patients treated with radical prostatectomy for a clinically localized prostate cancer diagnosed on magnetic resonance imaging-transrectal ultrasound targeted biopsy and/or systematic biopsy. On multiparametric magnetic resonance imaging each suspicious area was graded according to PI-RADS™ score. A correlation analysis between multiparametric magnetic resonance imaging and pathological findings was performed. Factors associated with determining the accuracy of Gleason score on targeted biopsy were statistically assessed. Pathological analysis of radical prostatectomy specimens detected 230 tumor foci. Multiparametric magnetic resonance imaging detected 151 suspicious areas. Of these areas targeted biopsy showed 126 cancer foci in 115 patients, and detected the index lesion in all of them. The primary Gleason grade, secondary Gleason grade and Gleason score of the 126 individual tumors were determined accurately in 114 (90%), 75 (59%) and 85 (67%) cases, respectively. Maximal Gleason score was determined accurately in 80 (70%) patients. Gleason score determination accuracy on targeted biopsy was significantly higher for low Gleason and high PI-RADS score tumors. Magnetic resonance imaging-transrectal ultrasound targeted biopsy allowed for an accurate estimation of Gleason score in more than two-thirds of patients. Gleason score misclassification was mostly due to a lack of accuracy in the determination of the secondary Gleason grade. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.

    PubMed

    Baez, E; Huber, A; Vetter, M; Hackelöer, B-J

    2003-03-01

    The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are ultrasound offers the advantage of better preoperative demonstration of the lesions' margins, resulting in better assessment of volumetry, improved intraoperative needle location and perioperative

  6. Development of a fresh cadaver model for instruction of ultrasound-guided breast biopsy during the surgery clerkship: pre-test and post-test results among third-year medical students.

    PubMed

    McCrary, Hilary C; Krate, Jonida; Savilo, Christine E; Tran, Melissa H; Ho, Hang T; Adamas-Rappaport, William J; Viscusi, Rebecca K

    2016-11-01

    The aim of our study was to determine if a fresh cadaver model is a viable method for teaching ultrasound (US)-guided breast biopsy of palpable breast lesions. Third-year medical students were assessed both preinstruction and postinstruction on their ability to perform US-guided needle aspiration or biopsy of artificially created masses using a 10-item checklist. Forty-one third-year medical students completed the cadaver laboratory as part of the surgery clerkship. Eight items on the checklist were found to be significantly different between pre-testing and post-testing. The mean preinstruction score was 2.4, whereas the mean postinstruction score was 7.10 (P < .001). Fresh cadaver models have been widely used in medical education. However, there are few fresh cadaver models that provide instruction on procedures done in the outpatient setting. Our model was found to be an effective method for the instruction of US-guided breast biopsy among medical students. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Ultrasound-guided medical thoracoscopy in the absence of pleural effusion.

    PubMed

    Marchetti, Giampietro; Valsecchi, Alberto; Indellicati, Davide; Arondi, Sabrina; Trigiani, Marco; Pinelli, Valentina

    2015-04-01

    Medical thoracoscopy (MT) is a diagnostic and therapeutic procedure that permits the study of the pleural space. The presence of pleural adhesions is the most important contraindication to performing MT. Lesions of the pleura in absence of pleural effusion are usually studied in video-assisted thoracoscopic surgery (VATS) with preoperative ultrasound evaluation. No data are available about ultrasound-guided MT in the absence of pleural effusion. From January 2007 to June 2013, 622 consecutive MTs were performed under ultrasound guidance without inducing a pneumothorax. A retrospective cohort of 29 patients affected by pleural diseases without fluid was reviewed. The fifth or sixth intercostal spaces along the midaxillary line with a good echographic "sliding sign" and normal appearance of the pleural line were chosen as the entry site. The pleural cavity was explored, and biopsies were performed. The mean age of the patient cohort was 62.8 years; there were 20 male patients and nine female patients. Pleural adherences were avoided, and adequate number of pleural biopsies were performed. No parenchymal lung injuries, bleeding, or hematoma occurred. Seventeen patients had a completely free pleural cavity, four patients had a single pleural adhesion, and eight had multiple pleural adhesions; in all cases, however, endoscopic exploration was possible and biopsy specimens were adequate. The most frequent histopathologic diagnosis was malignant pleural mesothelioma. We have shown that thoracic ultrasound accurately identifies intrathoracic adhesions and, in experienced hands, can guide MT access, replacing the VATS approach, even in the complete absence of pleural effusion.

  8. Effect of Prostate Magnetic Resonance Imaging/Ultrasound Fusion-guided Biopsy on Radiation Treatment Recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, Aaron; Valle, Luca F.; Shankavaram, Uma

    Purpose: Targeted magnetic resonance imaging (MRI)/ultrasound fusion prostate biopsy (MRI-Bx) has recently been compared with the standard of care extended sextant ultrasound-guided prostate biopsy (SOC-Bx), with the former associated with an increased rate of detection of clinically significant prostate cancer. The present study sought to determine the influence of MRI-Bx on radiation therapy and androgen deprivation therapy (ADT) recommendations. Methods and Materials: All patients who had received radiation treatment and had undergone SOC-Bx and MRI-Bx at our institution were included. Using the clinical T stage, pretreatment prostate-specific antigen, and Gleason score, patients were categorized into National Comprehensive Cancer Network riskmore » groups and radiation treatment or ADT recommendations assigned. Intensification of the recommended treatment after multiparametric MRI, SOC-Bx, and MRI-Bx was evaluated. Results: From January 2008 to January 2016, 73 patients received radiation therapy at our institution after undergoing a simultaneous SOC-Bx and MRI-Bx (n=47 with previous SOC-Bx). Repeat SOC-Bx and MRI-Bx resulted in frequent upgrading compared with previous SOC-Bx (Gleason score 7, 6.7% vs 44.6%; P<.001; Gleason score 8-10, 2.1% vs 38%; P<.001). MRI-Bx increased the proportion of patients classified as very high risk from 24.7% to 41.1% (P=.027). Compared with SOC-Bx alone, including the MRI-Bx findings resulted in a greater percentage of pathologically positive cores (mean 37% vs 44%). Incorporation of multiparametric MRI and MRI-Bx results increased the recommended use and duration of ADT (duration increased in 28 of 73 patients and ADT was added for 8 of 73 patients). Conclusions: In patients referred for radiation treatment, MRI-Bx resulted in an increase in the percentage of positive cores, Gleason score, and risk grouping. The benefit of treatment intensification in accordance with the MRI-Bx findings is unknown.« less

  9. Non-malignant breast papillary lesions - b3 diagnosed on ultrasound--guided 14-gauge needle core biopsy: analysis of 114 cases from a single institution and review of the literature.

    PubMed

    Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico

    2015-07-01

    One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).

  10. Granulomatous mastitis: changing clinical and imaging features with image-guided biopsy correlation.

    PubMed

    Handa, Priyanka; Leibman, A Jill; Sun, Derek; Abadi, Maria; Goldberg, Aryeh

    2014-10-01

    To review clinical presentation, revisit patient demographics and imaging findings in granulomatous mastitis and determine the optimal biopsy method for diagnosis. A retrospective study was performed to review the clinical presentation, imaging findings and biopsy methods in patients with granulomatous mastitis. Twenty-seven patients with pathology-proven granulomatous mastitis were included. The average age at presentation was 38.0 years (range, 21-73 years). Seven patients were between 48 and 73 years old. Twenty-four patients presented with symptoms and three patients were asymptomatic. Nineteen patients were imaged with mammography demonstrating mammographically occult lesions as the predominant finding. Twenty-six patients were imaged with ultrasound and the most common finding was a mass lesion. Pathological diagnosis was made by image-guided biopsy in 44 % of patients. The imaging features of granulomatous mastitis on mammography are infrequently described. Our study demonstrates that granulomatous mastitis can occur in postmenopausal or asymptomatic patients, although previously reported exclusively in young women with palpable findings. Presentation on mammography as calcifications requiring mammographically guided vacuum-assisted biopsy has not been previously described. The diagnosis of granulomatous mastitis can easily be made by image-guided biopsy and surgical excision should be reserved for definitive treatment. • Characterizes radiographic appearance of granulomatous mastitis in postmenopausal or asymptomatic patients. • Granulomatous mastitis can present exclusively as calcifications on mammography. • The diagnosis of granulomatous mastitis is made by image-guided biopsy techniques.

  11. Comparison of the complications of traditional 12 cores transrectal prostate biopsy with image fusion guided transperineal prostate biopsy.

    PubMed

    Huang, Haifeng; Wang, Wei; Lin, Tingsheng; Zhang, Qing; Zhao, Xiaozhi; Lian, Huibo; Guo, Hongqian

    2016-11-17

    To compare the complications of traditional transrectal (TR) prostate biopsy and image fusion guided transperineal (TP) prostate biopsy in our center. Two hundred and fourty-two patients who underwent prostate biopsy from August 2014 to January 2015were reviewed. Among them, 144 patients underwent systematic 12-core transrectal ultrasonography (TRUS) guided prostate biopsy (TR approach) while 98 patients underwent free-hand transperineal targeted biopsy with TRUS and multi-parameter magnetic resonance imaging (mpMRI) fusion images (TP approach). The complications of the two groups were presented and a simple statistical analysis was performed to compare the two groups. The cohort of our study include242 patients, including 144 patients underwent TR biopsies while 98 patients underwentTP biopsies. There was no significant difference of major complications, including sepsis, bleeding and other complication requiring admissionbetween the two groups (P > 0.05). The incidence rate of infection and rectal bleeding in TR was much higher than TP (p < 0.05), but the incidence rate of perineal swelling in TP was much higher than TR (p < 0.05). There were no significant differences of minor complications including hematuria, lower urinary tract symptoms (LUTS), dysuria, and acuteurinary retention between the two groups (p > 0.05). The present study supports the safety of both techniques. Free-handTP targeted prostate biopsy with real-time fusion imaging of mpMRI and TR ultrasound is a good approach for prostate biopsy.

  12. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    PubMed

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  13. Identification of threshold prostate specific antigen levels to optimize the detection of clinically significant prostate cancer by magnetic resonance imaging/ultrasound fusion guided biopsy.

    PubMed

    Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A

    2014-12-01

    Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases

  14. Possibility of transrectal photoacoustic imaging-guided biopsy for detection of prostate cancer

    NASA Astrophysics Data System (ADS)

    Ishihara, Miya; Shinchi, Masayuki; Horiguchi, Akio; Shinmoto, Hiroshi; Tsuda, Hitoshi; Irisawa, Kaku; Wada, Takatsugu; Asano, Tomohiko

    2017-03-01

    A transrectral ultrasonography (TRUS) guided prostate biopsy is mandatory for histological diagnosis in patients with an elevated serum prostate-specific antigen (PSA), but its diagnostic accuracy is not satisfactory; therefore, a considerable number of patients are forced to have an unnecessary repeated biopsy. Photoacoustic (PA) imaging has the ability to visualize the distribution of hemoglobin clearly. Thus, there is the potential to acquire different maps of small vessel networks between cancerous and normal tissue. We developed an original TRUS-type PA probe consisting of a microconvex array transducer with an optical illumination system providing coregistered PA and ultrasound images. The purpose of this study is to demonstrate the clinical possibility of a transrectral PA image. The prostate biopsy cores obtained by transrectal systemic biopsies under TRUS guidance were stained with HE staining and anti-CD34 antibodies as a marker of the endothelium of the blood vessel in order to find a pattern in the map of a small vessel network, which allows for imaging-based identification of prostate cancer. We analyzed the association of PA signal patterns, the cancer location by a magnetic resonance imaging (MRI) study, and the pathological diagnosis with CD34 stains as a prospective intervention study. In order to demonstrate the TRUS-merged-with-PA imaging guided targeted biopsy combined with a standard biopsy for capturing the clinically significant tumors, we developed a puncture needle guide attachment for the original TRUS-type PA probe.

  15. Ultrasound guided fine needle aspiration biopsy of parathyroid gland and lesions.

    PubMed

    Dimashkieh, Haytham; Krishnamurthy, Savitri

    2006-03-28

    Parathyroid gland and their tumors comprise a small proportion of non-palpable neck masses that are investigated by ultrasound (US) guided fine needle aspiration biopsy. We reviewed our institution's cases of US guided FNAB of parathyroid gland and their lesions to determine the role of cytology for the preoperative diagnosis of parathyroid gland and their lesions. All cases of FNAB of parathyroid gland and lesions in the last 10 years were reviewed in detail with respect to clinical history and correlated with the histopathologic findings in available cases. The cytologic parameters that were evaluated included cellularity assessed semiquantitatively as scant, intermediate or abundant (<50, 51-500 or >500 cells), cellular distribution (loose clusters, single cells/naked nuclei, rounded clusters, two- and three-dimensional clusters, and presence of prominent vascular proliferation), cellular characteristics (cell size, nuclear shape, presence/absence of a nucleolus, degree of mitosis, amount of cytoplasm, and appearance of nuclear chromatin), and background (colloid-like material and macrophages). Immunostaining for parathyroid hormone (PTH) was performed on selected cases using either destained Pap smears or cell block sections. Twenty cases of US-guided FNAB of parathyroid glands and their lesions including 13 in the expected locations in the neck, 3 in intrathyroid region, 3 in thyroid bed, and 1 metastatic to liver were studied. Majority of the cases showed intermediate cellularity (51-500 cells) with round to oval cells that exhibited a stippled nuclear chromatin, without significant pleomorphism or mitotic activity. The cells were arranged in loose two dimensional groups with many single cells/naked nuclei around the groups. Occasionally macrophages and colloid like material was also encountered. There was no significant difference in the cytomorphologic features between normal gland, hyperplasia adenoma, or carcinoma. Immunocytochemical analysis for PHT was

  16. Percutaneous CT-guided biopsy of the spine: results of 430 biopsies

    PubMed Central

    Rimondi, Eugenio; Errani, Costantino; Bianchi, Giuseppe; Casadei, Roberto; Alberghini, Marco; Malaguti, Maria Cristina; Rossi, Giuseppe; Durante, Stefano; Mercuri, Mario

    2008-01-01

    Biopsies of lesions in the spine are often challenging procedures with significant risk of complications. CT-guided needle biopsies could lower these risks but uncertainties still exist about the diagnostic accuracy. Aim of this retrospective study was to evaluate the diagnostic accuracy of CT-guided needle biopsies for bone lesions of the spine. We retrieved the results of 430 core needle biopsies carried out over the past fifteen years at the authors’ institute and examined the results obtained. Of the 430 biopsies performed, in 401 cases the right diagnosis was made with the first CT-guided needle biopsy (93.3% accuracy rate). Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, inflammatory, and systemic pathologies. There were only 9 complications (5 transient paresis, 4 haematomas that resolved spontaneously) that had no influence on the treatment strategy, nor on the patient’s outcome. In conclusion we can assert that this technique is reliable and safe and should be considered the gold standard in biopsies of the spine. PMID:18463900

  17. Outbreak of fluoroquinolone-resistant Escherichia coli infections after transrectal ultrasound-guided biopsy of the prostate.

    PubMed

    Dumford, Donald; Suwantarat, Nuntra; Bhasker, Vineet; Kundrapu, Sirisha; Zabarsky, Trina F; Drawz, Paul; Zhu, Hui; Donskey, Curtis J

    2013-03-01

    We conducted an investigation after identifying a cluster of 4 serious infections following transrectal ultrasound-guided biopsy of the prostate (TRUBP) during a 2-month period. Veterans Affairs medical center. Patients with urinary tract infection (UTI) after TRUBP and time-matched controls with no evidence of infection. The incidence of UTI within 30 days after TRUBP was calculated from 2002 through 2010. We evaluated the correlation between infection with fluoroquinolone-resistant gram-negative bacilli (GNB) and fluoroquinolone resistance in outpatient Escherichia coli urinary isolates and performed a case-control study to determine risk factors for infection with fluoroquinolone-resistant GNB. Processes for TRUBP prophylaxis, procedures, and equipment sterilization were reviewed. An outbreak of UTI due to fluoroquinolone-resistant E. coli after TRUBP began 2 years before the cluster was identified and was correlated with increasing fluoroquinolone resistance in outpatient E. coli. No deficiencies were identified in equipment processing or biopsy procedures. Fluoroquinolone-resistant E. coli UTI after TRUBP was independently associated with prior infection with fluoroquinolone-resistant GNB (adjusted odds ratio, 20.8; P=.005). A prediction rule including prior UTI, hospitalization in the past year, and previous infection with fluoroquinolone-resistant GNB identified only 17 (49%) of 35 cases. The outbreak of fluoroquinolone-resistant E. coli infections after TRUBP closely paralleled rising rates of fluoroquinolone resistance among outpatient E. coli isolates. The delayed detection of the outbreak and the absence of sensitive predictors of infection suggest that active surveillance for infection after TRUBP is necessary in the context of increasing fluoroquinolone resistance in the United States.

  18. Cost-effectiveness comparison between palpation- and ultrasound-guided thyroid fine-needle aspiration biopsies.

    PubMed

    Can, Ahmet Selçuk

    2009-05-16

    The aim of this study is to perform a cost-effectiveness comparison between palpation-guided thyroid fine-needle aspiration biopsies (P-FNA) and ultrasound-guided thyroid FNA biopsies (USG-FNA). Each nodule was considered as a case. Diagnostic steps were history and physical examination, TSH measurement, Tc99m thyroid scintigraphy for nodules with a low TSH level, initial P-FNA versus initial USG-FNA, repeat USG-FNA for nodules with initial inadequate P-FNA or USG-FNA, hemithyroidectomy for inadequate repeat USG-FNA. American Thyroid Association thyroid nodule management guidelines were simulated in estimating the cost of P-FNA strategy. American Association of Clinical Endocrinologists guidelines were simulated for USG-FNA strategy. Total costs were estimated by adding the cost of each diagnostic step to reach a diagnosis for 100 nodules. Strategy cost was found by dividing the total cost to 100. Incremental cost-effectiveness ratio (ICER) was calculated by dividing the difference between strategy cost of USG-FNA and P-FNA to the difference between accuracy of USG-FNA and P-FNA. A positive ICER indicates more and a negative ICER indicates less expense to achieve one more additional accurate diagnosis of thyroid cancer for USG-FNA. Seventy-eight P-FNAs and 190 USG-FNAs were performed between April 2003 and May 2008. There were no differences in age, gender, thyroid function, frequency of multinodular goiter, nodule location and diameter (median nodule diameter: 18.4 mm in P-FNA and 17.0 mm in USG-FNA) between groups. Cytology results in P-FNA versus USG-FNA groups were as follows: benign 49% versus 62% (p = 0.04), inadequate 42% versus 29% (p = 0.03), malignant 3% (p = 1.00) and indeterminate 6% (p = 0.78) for both. Eleven nodules from P-FNA and 18 from USG-FNA group underwent surgery. The accuracy of P-FNA was 0.64 and USG-FNA 0.72. Unit cost of P-FNA was 148 Euros and USG-FNA 226 Euros. The cost of P-FNA strategy was 534 Euros and USG-FNA strategy 523 Euros

  19. Cost-effectiveness comparison between palpation- and ultrasound-guided thyroid fine-needle aspiration biopsies

    PubMed Central

    Can, Ahmet Selçuk

    2009-01-01

    Background The aim of this study is to perform a cost-effectiveness comparison between palpation-guided thyroid fine-needle aspiration biopsies (P-FNA) and ultrasound-guided thyroid FNA biopsies (USG-FNA). Methods Each nodule was considered as a case. Diagnostic steps were history and physical examination, TSH measurement, Tc99m thyroid scintigraphy for nodules with a low TSH level, initial P-FNA versus initial USG-FNA, repeat USG-FNA for nodules with initial inadequate P-FNA or USG-FNA, hemithyroidectomy for inadequate repeat USG-FNA. American Thyroid Association thyroid nodule management guidelines were simulated in estimating the cost of P-FNA strategy. American Association of Clinical Endocrinologists guidelines were simulated for USG-FNA strategy. Total costs were estimated by adding the cost of each diagnostic step to reach a diagnosis for 100 nodules. Strategy cost was found by dividing the total cost to 100. Incremental cost-effectiveness ratio (ICER) was calculated by dividing the difference between strategy cost of USG-FNA and P-FNA to the difference between accuracy of USG-FNA and P-FNA. A positive ICER indicates more and a negative ICER indicates less expense to achieve one more additional accurate diagnosis of thyroid cancer for USG-FNA. Results Seventy-eight P-FNAs and 190 USG-FNAs were performed between April 2003 and May 2008. There were no differences in age, gender, thyroid function, frequency of multinodular goiter, nodule location and diameter (median nodule diameter: 18.4 mm in P-FNA and 17.0 mm in USG-FNA) between groups. Cytology results in P-FNA versus USG-FNA groups were as follows: benign 49% versus 62% (p = 0.04), inadequate 42% versus 29% (p = 0.03), malignant 3% (p = 1.00) and indeterminate 6% (p = 0.78) for both. Eleven nodules from P-FNA and 18 from USG-FNA group underwent surgery. The accuracy of P-FNA was 0.64 and USG-FNA 0.72. Unit cost of P-FNA was 148 Euros and USG-FNA 226 Euros. The cost of P-FNA strategy was 534 Euros and USG

  20. Real-time 3D ultrasound guidance of autonomous surgical robot for shrapnel detection and breast biopsy

    NASA Astrophysics Data System (ADS)

    Rogers, Albert J.; Light, Edward D.; von Allmen, Daniel; Smith, Stephen W.

    2009-02-01

    Two studies have been conducted using real time 3D ultrasound and an automated robot system for carrying out surgical tasks. The first task is to perform a breast lesion biopsy automatically after detection by ultrasound. Combining 3D ultrasound with traditional mammography allows real time guidance of the biopsy needle. Image processing techniques analyze volumes to calculate the location of a target lesion. This position was converted into the coordinate system of a three axis robot which moved a needle probe to touch the lesion. The second task is to remove shrapnel from a tissue phantom autonomously. In some emergency situations, shrapnel detection in the body is necessary for quick treatment. Furthermore, small or uneven shrapnel geometry may hinder location by typical ultrasound imaging methods. Vibrations and small displacements can be induced in ferromagnetic shrapnel by a variable electromagnet. We used real time 3D color Doppler to locate this motion for 2 mm long needle fragments and determined the 3D position of the fragment in the scanner coordinates. The rms error of the image guided robot for 5 trials was 1.06 mm for this task which was accomplished in 76 seconds.

  1. Clinical utility of transperineal template-guided mapping biopsy of the prostate after negative magnetic resonance imaging-guided transrectal biopsy.

    PubMed

    Sivaraman, Arjun; Sanchez-Salas, Rafael; Ahmed, Hashim U; Barret, Eric; Cathala, Nathalie; Mombet, Annick; Uriburu Pizarro, Facundo; Carneiro, Arie; Doizi, Steeve; Galiano, Marc; Rozet, Francois; Prapotnich, Dominique; Cathelineau, Xavier

    2015-07-01

    We evaluated the prostate cancer detection with transperineal template-guided mapping biopsy in patients with elevated prostate-specific antigen and negative magnetic resonance imaging (MRI)-guided biopsy. Totally 75 patients underwent transperineal template-guided mapping biopsy for prior negative MRI-guided (cognitive registration) biopsy during April 2013 to August 2014. Primary objective was to report clinically significant cancer detection in this cohort of patients. Significant cancer was defined using varying thresholds of MCL or Gleason grade 3+4 or greater or both. Cancers with more than 80% of positive core length anterior to the level of urethra were termed anterior zone cancer. Secondary objective was to evaluate the potential clinical and radiological predictors for significant cancer detection. The mean age was 61.6 ± 6.5 years and median prostate-specific antigen was 10.4 ng/dl (7.9-18) with a mean MRI target size of 7.2mm (4-11). Transperineal template-guided mapping biopsy identified cancer in 36% (27/75) patients and 66.6% (18/27) of them were anterior zone cancers. The rates of detection of clinically significant and insignificant cancer according to the several definitions used range from 22.7% to 30.7% and 5.3% to 13.3%, respectively. Multivariate analysis did not identify any predictors for finding clinically significant and anterior cancers in this group of patients. Transperineal template-guided mapping biopsy appears to be an excellent biopsy protocol for downstream management following negative MRI-guided biopsy. Most of the cancers detected were predominantly anterior tumors. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. [Ultrasonography of the prostate gland : From B‑image through multiparametric ultrasound to targeted biopsy].

    PubMed

    Steinkohl, F; Luger, A; Bektic, J; Aigner, F

    2017-08-01

    Prostate cancer is the most frequent cancer in men. The diagnosis is normally achieved by a systematic prostate biopsy; however, this is a randomized approach by which a substantial number of significant carcinomas go undetected. For this reason, in recent years imaging techniques have been continuously developed, which enable visualization and therefore targeted biopsies. The use of systematic biopsies is a standard procedure for the detection of prostate cancer. The quality of biopsies can be increased if the prostate is examined for the presence of suspected cancerous alterations during the biopsy. This can be carried out using multiparametric transrectral ultrasound. Multiparametric ultrasound within the framework of a targeted biopsy increases the detection rate of significant prostate carcinomas with a simultaneous decrease in detection of insignificant carcinomas; however, the diagnostic reliability and the evidence level of multiparametric transrectal ultrasound are not yet sufficiently high to be able to replace a systematic biopsy. In the hands of a well-trained examiner multiparametric transrectal ultrasound represents a good method for detection of prostate carcinomas. With the progression in technical developments of ultrasound technology, the detection rate will presumably be further increased.

  3. Contrast-Enhanced Ultrasound Improves the Pathological Outcomes of US-Guided Core Needle Biopsy That Targets the Viable Area of Anterior Mediastinal Masses

    PubMed Central

    Zhou, Jian-hua; Shan, Hong-bo; Ou, Wei; Mo, Yun-xian; Xiang, Jin; Wang, Yu; Wang, Si-yu

    2018-01-01

    Based on the option that ultrasound-guided core needle biopsy (US-CNB) of the enhanced portion of anterior mediastinal masses (AMMs) identified by contrast-enhanced ultrasound (CEUS) would harvest viable tissue and benefit the histological diagnoses, a retrospective study was performed to elucidate the correlation between the prebiopsy CEUS and diagnostic yield of AMMs and found that CEUS potentially improved the diagnostic yield of AMMs compared with conventional US with a significant increase in the cellularity of samples. Furthermore, the marginal blood flow signals and absence of necrosis can predict the diagnostic yield of AMM. It was concluded that US-CNB of the viable part of AMMs, as verified by CEUS, was able to harvest sufficient tissue with more cellularity that could be used for ancillary studies and improve the diagnostic yield. And CEUS was recommended to those patients with AMMs undergoing repeated US-CNB, with the absence of marginal blood signals or presence of necrosis. PMID:29581992

  4. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    PubMed

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 or greater was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  5. Segmentation of prostate biopsy needles in transrectal ultrasound images

    NASA Astrophysics Data System (ADS)

    Krefting, Dagmar; Haupt, Barbara; Tolxdorff, Thomas; Kempkensteffen, Carsten; Miller, Kurt

    2007-03-01

    Prostate cancer is the most common cancer in men. Tissue extraction at different locations (biopsy) is the gold-standard for diagnosis of prostate cancer. These biopsies are commonly guided by transrectal ultrasound imaging (TRUS). Exact location of the extracted tissue within the gland is desired for more specific diagnosis and provides better therapy planning. While the orientation and the position of the needle within clinical TRUS image are limited, the appearing length and visibility of the needle varies strongly. Marker lines are present and tissue inhomogeneities and deflection artefacts may appear. Simple intensity, gradient oder edge-detecting based segmentation methods fail. Therefore a multivariate statistical classificator is implemented. The independent feature model is built by supervised learning using a set of manually segmented needles. The feature space is spanned by common binary object features as size and eccentricity as well as imaging-system dependent features like distance and orientation relative to the marker line. The object extraction is done by multi-step binarization of the region of interest. The ROI is automatically determined at the beginning of the segmentation and marker lines are removed from the images. The segmentation itself is realized by scale-invariant classification using maximum likelihood estimation and Mahalanobis distance as discriminator. The technique presented here could be successfully applied in 94% of 1835 TRUS images from 30 tissue extractions. It provides a robust method for biopsy needle localization in clinical prostate biopsy TRUS images.

  6. Thoracic ultrasound-assisted selection for pleural biopsy with Abrams needle.

    PubMed

    Botana-Rial, Maribel; Leiro-Fernández, Virginia; Represas-Represas, Cristina; González-Piñeiro, Ana; Tilve-Gómez, Amara; Fernández-Villar, Alberto

    2013-11-01

    Closed pleural biopsy (CPB) in patients with malignant pleural effusion is less sensitive than cytology. Ultrasound-assisted CPB allows biopsies to be performed in the lower thoracic parietal pleura, where secondary spread from pleural metastases is initially more likely to be found. We analyzed whether choosing the point of entry for CPB with thoracic ultrasound assistance influences the diagnostic yield in malignant pleural effusion. This prospective study included patients who underwent CPB performed by an experienced pulmonologist in 2008-2010 (group A) and thoracic ultrasound was used to select the biopsy site. The results were compared with a historical series of CPB performed by the same pulmonologist without the assistance of thoracic ultrasound (group B). An Abrams needle was used in all cases. We analyzed the obtaining of pleural tissue and the diagnostic yield. We included 114 CPBs from group A (23% tuberculous pleural effusion, 27% malignant pleural effusion) and 67 CPBs from group B (24% tuberculous pleural effusion, 30% malignant pleural effusion) (P = .70). Pleural tissue was obtained in 96.5% of the group A CPBs and 89.6% of the group B CPBs (P = .05). The diagnostic yields of CPB for tuberculous pleural effusion and malignant pleural effusion in group A were 89.5% and 77.4%, respectively, and 91.7% and 60%, respectively, in group B (P = .80 for tuberculous pleural effusion, and P = .18 for malignant pleural effusion). Selecting the point of entry for CPB using thoracic ultrasound increases the likelihood of obtaining pleural tissue and the diagnostic yield, but without statistical significance. We recommend ultrasound-assisted CPB to investigate pleural effusion, since the diagnostic yield of a pleural biopsy with an Abrams needle increased by > 17% in subjects with malignant pleural effusion.

  7. The challenging image-guided abdominal mass biopsy: established and emerging techniques 'if you can see it, you can biopsy it'.

    PubMed

    Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G

    2013-08-01

    Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.

  8. Ultrasound- and MRI-Guided Prostate Biopsy

    MedlinePlus

    ... which the MR images are fused with the real-time ultrasound images — an approach known as MRI/TRUS ... by a computer, which in turn creates a real-time picture on the monitor. One or more frames ...

  9. MR-guided Focused Ultrasound for Uterine Fibroids

    MedlinePlus

    ... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...

  10. Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis

    PubMed Central

    Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao

    2013-01-01

    AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631

  11. Elastic Versus Rigid Image Registration in Magnetic Resonance Imaging-transrectal Ultrasound Fusion Prostate Biopsy: A Systematic Review and Meta-analysis.

    PubMed

    Venderink, Wulphert; de Rooij, Maarten; Sedelaar, J P Michiel; Huisman, Henkjan J; Fütterer, Jurgen J

    2016-07-29

    The main difference between the available magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion platforms for prostate biopsy is the method of image registration being either rigid or elastic. As elastic registration compensates for possible deformation caused by the introduction of an ultrasound probe for example, it is expected that it would perform better than rigid registration. The aim of this meta-analysis is to compare rigid with elastic registration by calculating the detection odds ratio (OR) for both subgroups. The detection OR is defined as the ratio of the odds of detecting clinically significant prostate cancer (csPCa) by MRI-TRUS fusion biopsy compared with systematic TRUS biopsy. Secondary objectives were the OR for any PCa and the OR after pooling both registration techniques. The electronic databases PubMed, Embase, and Cochrane were systematically searched for relevant studies according to the Preferred Reporting Items for Systematic Review and Meta-analysis Statement. Studies comparing MRI-TRUS fusion and systematic TRUS-guided biopsies in the same patient were included. The quality assessment of included studies was performed using the Quality Assessment of Diagnostic Accuracy Studies version 2. Eleven papers describing elastic and 10 describing rigid registration were included. Meta-analysis showed an OR of csPCa for elastic and rigid registration of 1.45 (95% confidence interval [CI]: 1.21-1.73, p<0.0001) and 1.40 (95% CI: 1.13-1.75, p=0.002), respectively. No significant difference was seen between the subgroups (p=0.83). Pooling subgroups resulted in an OR of 1.43 (95% CI: 1.25-1.63, p<0.00001). No significant difference was identified between rigid and elastic registration for MRI-TRUS fusion-guided biopsy in the detection of csPCa; however, both techniques detected more csPCa than TRUS-guided biopsy alone. We did not identify any significant differences in prostate cancer detection between two distinct magnetic resonance

  12. Optimization of prostate biopsy: the role of magnetic resonance imaging targeted biopsy in detection, localization and risk assessment.

    PubMed

    Bjurlin, Marc A; Meng, Xiaosong; Le Nobin, Julien; Wysock, James S; Lepor, Herbert; Rosenkrantz, Andrew B; Taneja, Samir S

    2014-09-01

    Optimization of prostate biopsy requires addressing the shortcomings of standard systematic transrectal ultrasound guided biopsy, including false-negative rates, incorrect risk stratification, detection of clinically insignificant disease and the need for repeat biopsy. Magnetic resonance imaging is an evolving noninvasive imaging modality that increases the accurate localization of prostate cancer at the time of biopsy, and thereby enhances clinical risk assessment and improves the ability to appropriately counsel patients regarding therapy. In this review we 1) summarize the various sequences that comprise a prostate multiparametric magnetic resonance imaging examination along with its performance characteristics in cancer detection, localization and reporting standards; 2) evaluate potential applications of magnetic resonance imaging targeting in prostate biopsy among men with no previous biopsy, a negative previous biopsy and those with low stage cancer; and 3) describe the techniques of magnetic resonance imaging targeted biopsy and comparative study outcomes. A bibliographic search covering the period up to October 2013 was conducted using MEDLINE®/PubMed®. Articles were reviewed and categorized based on which of the 3 objectives of this review was addressed. Data were extracted, analyzed and summarized. Multiparametric magnetic resonance imaging consists of anatomical T2-weighted imaging coupled with at least 2 functional imaging techniques. It has demonstrated improved prostate cancer detection sensitivity up to 80% in the peripheral zone and 81% in the transition zone. A prostate cancer magnetic resonance imaging suspicion score has been developed, and is depicted using the Likert or PI-RADS (Prostate Imaging Reporting and Data System) scale for better standardization of magnetic resonance imaging interpretation and reporting. Among men with no previous biopsy, magnetic resonance imaging increases the frequency of significant cancer detection to 50

  13. Regional lymph node staging in breast cancer: the increasing role of imaging and ultrasound-guided axillary lymph node fine needle aspiration.

    PubMed

    Mainiero, Martha B

    2010-09-01

    The status of axillary lymph nodes is a key prognostic indicator in patients with breast cancer and helps guide patient management. Sentinel lymph node biopsy is increasingly being used as a less morbid alternative to axillary lymph node dissection. However, when sentinel lymph node biopsy is positive, axillary dissection is typically performed for complete staging and local control. Axillary ultrasound and ultrasound-guided fine needle aspiration (USFNA) are useful for detecting axillary nodal metastasis preoperatively and can spare patients sentinel node biopsy, because those with positive cytology on USFNA can proceed directly to axillary dissection or neoadjuvant chemotherapy. Internal mammary nodes are not routinely evaluated, but when the appearance of these nodes is abnormal on imaging, further treatment or metastatic evaluation may be necessary. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. Diagnosis of small pulmonary lesions by transbronchial lung biopsy with radial endobronchial ultrasound and virtual bronchoscopic navigation versus CT-guided transthoracic needle biopsy: A systematic review and meta-analysis

    PubMed Central

    Han, Yeji; Kim, Hyun Jung; Kong, Kyoung Ae; Kim, Soo Jung; Lee, Su Hwan; Ryu, Yon Ju; Lee, Jin Hwa; Kim, Yookyoung; Shim, Sung Shine

    2018-01-01

    Background Advances in bronchoscopy and CT-guided lung biopsy have improved the evaluation of small pulmonary lesions (PLs), leading to an increase in preoperative histological diagnosis. We aimed to evaluate the efficacy and safety of transbronchial lung biopsy using radial endobronchial ultrasound and virtual bronchoscopic navigation (TBLB-rEBUS&VBN) and CT-guided transthoracic needle biopsy (CT-TNB) for tissue diagnosis of small PLs. Methods A systematic search was performed in five electronic databases, including MEDLINE, EMBASE, Cochrane Library Central Register of Controlled Trials, Web of Science, and Scopus, for relevant studies in May 2016; the selected articles were assessed using meta-analysis. The articles were limited to those published after 2000 that studied small PLs ≤ 3 cm in diameter. Results From 7345 records, 9 articles on the bronchoscopic (BR) approach and 15 articles on the percutaneous (PC) approach were selected. The pooled diagnostic yield was 75% (95% confidence interval [CI], 69–80) using the BR approach and 93% (95% CI, 90–96) using the PC approach. For PLs ≤ 2 cm, the PC approach (pooled diagnostic yield: 92%, 95% CI: 88–95) was superior to the BR approach (66%, 95% CI: 55–76). However, for PLs > 2 cm but ≤ 3 cm, the diagnostic yield using the BR approach was improved to 81% (95% CI, 75–85). Complications of pneumothorax and hemorrhage were rare with the BR approach but common with the PC approach. Conclusions CT-TNB was superior to TBLB-rEBUS&VBN for the evaluation of small PLs. However, for lesions greater than 2 cm, the BR approach may be considered considering its diagnostic yield of over 80% and the low risk of procedure-related complications. PMID:29357388

  15. Ductal carcinoma in situ diagnosed using an ultrasound-guided 14-gauge core needle biopsy of breast masses: can underestimation be predicted preoperatively?

    PubMed Central

    2014-01-01

    Purpose: This study was designed to determine the rate of ductal carcinoma in situ (DCIS)underestimation diagnosed after an ultrasound-guided 14-gauge core needle biopsy (US-14G-CNB) of breast masses and to compare the clinical and imaging characteristics between trueDCIS and underestimated DCIS identified following surgical excision. Methods: Among 3,124 US-14G-CNBs performed for breast masses, 69 lesions in 60 patients were pathologically-determined to be pure DCIS. We classified these patients according to the final pathology after surgical excision as those with invasive ductal carcinoma (underestimated group) and those with DCIS (non-underestimated group). We retrospectively reviewed and compared the clinical and imaging characteristics between the two groups. Results: Of the 69 lesions, 21 were shown after surgery to be invasive carcinomas; the rateof DCIS underestimation was 30.4%. There were no statistically significant differences withrespect to the clinical symptoms, age, lesion size, mammographic findings, and ultrasonographic findings except for the presence of abnormal axillary lymph nodes as detected on ultrasound. The lesions in 2 patients in the non-underestimated group (2/41, 4.9%) and 5 patients in the underestimated group (5/19, 26.3%) were associated with abnormal lymph nodes on axillary ultrasound, and the presence of abnormal axillary lymph nodes on ultrasound was tatistically significant (P=0.016). Conclusion: We found a 30.4% rate of DCIS underestimation in breast masses based on a US-14G-CNB. The presence of abnormal lymph nodes as detected on axillary ultrasound may be useful to preoperatively predict underestimation. PMID:24936506

  16. Optimizing modality selection for image-guided procedures: an analysis of the challenges to ultrasound guidance.

    PubMed

    Beland, Michael D; Sternick, Laura A; Baird, Grayson L; Dupuy, Damian E; Cronan, John J; Mayo-Smith, William W

    2016-04-01

    Selection of the most appropriate modality for image guidance is essential for procedural success. We identified specific factors contributing to failure of ultrasound-guided procedures that were subsequently performed using CT guidance. This single-center, retrospective study included 164 patients who underwent a CT-guided biopsy, aspiration/drainage, or ablation after initially having the same procedure attempted unsuccessfully with ultrasound guidance. Review of the procedure images, reports, biopsy results, and clinical follow-up was performed and the reasons for inability to perform the procedure with ultrasound guidance were recorded. Patient cross-sectional area and depth to target were calculated. Differences in area and depth were compared using general linear modeling. Depth as a predictor of an unfavorable body habitus designation was modeled using logistic regression. US guidance was successful in the vast majority of cases (97%). Of the 164 procedures, there were 92 (56%) biopsies, 63 (38%) aspirations/drainages, and 9 (5%) ablations. The most common reason for procedure failure was poor acoustic window (83/164, 51%). Other reasons included target lesion being poorly discerned from adjacent tissue (61/164, 37%), adjacent bowel gas (34/164, 21%), body habitus (27/164, 16%), and gas-containing collection (22/164, 13%). Within the biopsy subgroup, patients for whom body habitus was a limiting factor were found to have on average a larger cross-sectional area and lesion depth relative to patients whose body habitus was not a complicating factor (p < 0.0001 and p = 0.0009). Poor acoustic window was the most common reason for procedural failure with ultrasound guidance. In addition, as lesion depth increased, the odds that body habitus would limit the procedure also increased. If preliminary imaging suggests a limited sonographic window, particularly for deeper lesions, proceeding directly to CT guidance should be considered.

  17. Magnetic resonance imaging-ultrasound fusion biopsy for prediction of final prostate pathology.

    PubMed

    Le, Jesse D; Stephenson, Samuel; Brugger, Michelle; Lu, David Y; Lieu, Patricia; Sonn, Geoffrey A; Natarajan, Shyam; Dorey, Frederick J; Huang, Jiaoti; Margolis, Daniel J A; Reiter, Robert E; Marks, Leonard S

    2014-11-01

    We explored the impact of magnetic resonance imaging-ultrasound fusion prostate biopsy on the prediction of final surgical pathology. A total of 54 consecutive men undergoing radical prostatectomy at UCLA after fusion biopsy were included in this prospective, institutional review board approved pilot study. Using magnetic resonance imaging-ultrasound fusion, tissue was obtained from a 12-point systematic grid (mapping biopsy) and from regions of interest detected by multiparametric magnetic resonance imaging (targeted biopsy). A single radiologist read all magnetic resonance imaging, and a single pathologist independently rereviewed all biopsy and whole mount pathology, blinded to prior interpretation and matched specimen. Gleason score concordance between biopsy and prostatectomy was the primary end point. Mean patient age was 62 years and median prostate specific antigen was 6.2 ng/ml. Final Gleason score at prostatectomy was 6 (13%), 7 (70%) and 8-9 (17%). A tertiary pattern was detected in 17 (31%) men. Of 45 high suspicion (image grade 4-5) magnetic resonance imaging targets 32 (71%) contained prostate cancer. The per core cancer detection rate was 20% by systematic mapping biopsy and 42% by targeted biopsy. The highest Gleason pattern at prostatectomy was detected by systematic mapping biopsy in 54%, targeted biopsy in 54% and a combination in 81% of cases. Overall 17% of cases were upgraded from fusion biopsy to final pathology and 1 (2%) was downgraded. The combination of targeted biopsy and systematic mapping biopsy was needed to obtain the best predictive accuracy. In this pilot study magnetic resonance imaging-ultrasound fusion biopsy allowed for the prediction of final prostate pathology with greater accuracy than that reported previously using conventional methods (81% vs 40% to 65%). If confirmed, these results will have important clinical implications. Copyright © 2014 American Urological Association Education and Research, Inc. Published by

  18. ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION IN THE DIAGNOSIS OF ADRENAL METASTASIS IN A HIGH-RISK POPULATION.

    PubMed

    Zhang, Catherine D; Erickson, Dana; Levy, Michael J; Gleeson, Ferga C; Salomao, Diva R; Delivanis, Danae A; Bancos, Irina

    2017-12-01

    While the left adrenal gland is readily accessible via endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), data regarding the utility of EUS-FNA in the diagnosis of adrenal lesions remain limited. We aimed to ( 1) describe the clinical context, adverse event rate, and diagnostic performance of EUS-FNA, and ( 2) compare the safety profile and diagnostic accuracy of EUS-FNA with percutaneous adrenal biopsy. Single-center, retrospective cohort study. Medical records of patients who underwent adrenal EUS-FNA from 2005-2016 were reviewed. Biopsy outcomes were evaluated using a predefined reference standard. Results were compared to patients who underwent percutaneous biopsy (n = 419; 1994-2014) at the same institution. A total of 121 patients underwent EUS-FNA of 122 adrenal lesions (left [n = 121]; right [n = 1]; mean lesion size, 1.8 cm). Cytology was positive for malignancy in 35 (29%), suspicious for malignancy in 1 (1%), atypical in 1 (1%), negative for malignancy in 81 (66%), and nondiagnostic in 4 (3%). No adverse events were reported. EUS-FNA diagnosed metastasis with a sensitivity of 100%, specificity of 97.4%, positive predictive value of 91.7%, and negative predictive value of 100%. When compared to percutaneous biopsy, lesion size (1.8 cm vs. 3.7 cm; P<.001) and biopsy site (99% vs. 62% left adrenal; P<.001) were significantly different. EUS-FNA adverse event rate was lower than percutaneous biopsy (0% vs. 4%; P = .024), but nondiagnostic rates were similar (3.3% vs. 4.8%; P = .48). EUS-FNA is a sensitive technique to sample adrenal lesions in patients at high risk for adrenal metastasis with fewer adverse events compared to percutaneous biopsy. CI = confidence interval CT = computed tomography EUS-FNA = endoscopic ultrasound-guided fine-needle aspiration NPV = negative predictive value PPV = positive predictive value TUS = transabdominal ultra-sound.

  19. Impact of Sodium Bicarbonate-Buffered Lidocaine on Patient Pain During Image-Guided Breast Biopsy.

    PubMed

    Vasan, Alison; Baker, Jay A; Shelby, Rebecca A; Soo, Mary Scott C

    2017-09-01

    This randomized, double-blind controlled study evaluated the effectiveness of sodium bicarbonate-buffered lidocaine on reducing pain during imaging-guided breast biopsies. This prospective, HIPAA-compliant study randomly assigned 85 women undergoing ultrasound- or stereotactic-guided core-needle breast biopsies to receive intradermally and intraparenchymally either 1% lidocaine buffered with sodium bicarbonate (9:1 ratio) (bicarbonate study group) or 1% lidocaine alone (control group). Pain was evaluated using a 0-to-10 Likert pain scale during both intradermal and intraparenchymal anesthesia injections and during tissue sampling. Prebiopsy breast pain, anxiety, medical history, demographics, biopsy type, radiologist level of training, breast density, and lesion histology were recorded. Data were analyzed using analysis of variance and analysis of covariance. Unadjusted mean pain scores were 1.47 and 2.07 (study and control groups, respectively; P = .15) during intradermal injections, and 1.84 and 2.98 (study and control groups, respectively; P = .03) during intraparenchymal injections. Tissue sampling mean pain scores were .81 and 1.71 (study and control groups, respectively; P = .07). Moderator analyses found (1) among patients with preprocedural pain, those in the bicarbonate group experienced less intradermal injection pain (0.85 ± 1.23) than patients in the control group (2.50 ± 2.09); (2) among patients with fatty or scattered fibroglandular tissue, those in the bicarbonate group (1.35 ± 1.95) experienced less intraparenchymal injection pain than the control group (3.52 ± 3.13); and (3) during ultrasound-guided biopsies, patients in the bicarbonate group experienced less tissue-sampling pain (0.23 ± 0.63) than the control group (1.79 ± 3.05). Overall, buffering lidocaine with sodium bicarbonate significantly reduced pain during intraparenchymal injections, and additional pain reduction was found in certain patient subgroups during intradermal

  20. Endobronchial Ultrasound-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration.

    PubMed

    Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T

    2016-05-01

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA

  1. Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy.

    PubMed

    Kuang, Y; Hilgers, A; Sadiq, M; Cochran, S; Corner, G; Huang, Z

    2016-07-01

    Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications. Copyright © 2016 The Authors. Published by Elsevier B

  2. Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Surry, K. J. M.; Mills, G. R.; Bevan, K.

    2007-11-15

    Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM andmore » US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target

  3. Computerized transrectal ultrasound (C-TRUS) of the prostate: detection of cancer in patients with multiple negative systematic random biopsies.

    PubMed

    Loch, Tillmann

    2007-08-01

    This study was designed to compare the diagnostic yield of computerized transrectal ultrasound (C-TRUS) guided biopsies in the detection of prostate cancer in a group of men with a history of multiple systematic random biopsies with no prior evidence of prostate cancer. The question was asked: Can we detect cancer by C-TRUS that has been overlooked by multiple systematic biopsies? The entrance criteria for this study were prior negative systematic random biopsies regardless of number of biopsy sessions or number of individual biopsy cores. Serial static TRUS images were evaluated by C-TRUS, which assessed signal information independent of visual gray scale. Five C-TRUS algorithms were utilized to evaluate the information of the ultrasound signal. Interpretation of the results were documented and the most suspicious regions marked by C-TRUS were biopsied by guiding the needle to the marked location. Five hundred and forty men were biopsied because of an elevated PSA or abnormal digital rectal exam. 132 had a history of prior negative systematic random biopsies (1-7 sessions, median: 2 and between 6 and 72 individual prostate biopsies, median: 12 cores). Additionally, a diagnostic TUR-P of the prostate with benign result was performed in four patients. The PSA ranged from 3.1-36 ng/ml with a median of 9.01 ng/ml. The prostate volume ranged from 6-203 ml with a median of 42 ml. Of the 132 patients with prior negative systematic random biopsies, cancer was found in 66 (50%) by C-TRUS targeted biopsies. In this group the median number of negative biopsy sessions was two and a median of 12 biopsy cores were performed. From literature we would expect a cancer detection rate in this group with systematic biopsies of approximately 7%. We only found five carcinomas with a Gleason Score (GS) of 5, 25 with GS 6, 22 with GS 7, 8 with GS 8 and even 7 with GS 9. The results of this prospective clinical trail indicates that the additional use of the C-TRUS identifies clinical

  4. Ultrasound guided needle localization and microsurgical exploration for incidental nonpalpable testicular tumors.

    PubMed

    Hopps, Carin V; Goldstein, Marc

    2002-09-01

    We describe a technique by which incidental, nonpalpable intratesticular tumors are excised using intraoperative ultrasonography and the operating microscope. Men with impalpable intratesticular tumors incidentally detected by ultrasonography underwent intraoperative ultrasound guided needle localization and microsurgical exploration of the mass. The testis was delivered through an inguinal incision and placed on ice to minimize warm ischemia. Two rubber shod vascular clamps were placed across the spermatic cord. The tumor was identified by ultrasound and localized with a 30 gauge needle, which was placed adjacent to the tumor. An operating microscope providing 6x to 25x magnification was used to excise the lesion with a 2 to 5 mm. margin. Tissue diagnosis was obtained by frozen section. Multiple random biopsies of the remaining parenchyma were done to confirm absent malignancy. Ultrasound showed incidental, nonpalpable testis tumors in 4 of the 65 men who underwent infertility evaluation and were entered into the microsurgical testis biopsy database between January 1995 and December 2001. All lesions were hypoechoic. Frozen section analysis of the lesions revealed 2 Leydig cell tumors, 1 mass with an inconclusive pathological diagnosis and 1 inflammatory mass. On permanent section the latter 2 lesions were seminoma. The seminomas were 1.6 and 0.9 cm. in the greatest diameter, and the Leydig cell tumors were 0.35 and 0.2 cm., respectively. Random biopsies were positive for seminoma and intratubular germ cell neoplasia in both testes with seminoma. These 2 patients subsequently opted to undergo radical orchiectomy. No residual tumor was detected in either radical orchiectomy specimen. Intraoperative ultrasound guided needle localization with microsurgical exploration is a safe and effective approach to even small impalpable testicular masses. This technique provides the opportunity to identify and remove benign and malignant lesions, and preserve the testis when the

  5. Endobronchial ultrasound-guided transbronchial needle aspiration of pulmonary artery tumors: A systematic review (with video).

    PubMed

    Harris, Kassem; Modi, Kush; Kumar, Abhishek; Dhillon, Samjot Singh

    2015-01-01

    Convex probe endobronchial ultrasound (CP-EBUS) was originally introduced as a diagnostic and staging tool for lung cancer and subsequently utilized for diagnosis of other malignant and benign mediastinal diseases such as melanoma, lymphoma, and sarcoidosis. More recently, CP-EBUS has been successfully used for the visualization and diagnosis of pulmonary emboli and other vascular lesions including primary and metastatic pulmonary artery (PA) tumors. In this review, we will underline the role of EBUS-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of pulmonary arterial tumors such as sarcomas and tumor emboli. We will concisely discuss the clinical applications of EBUS-TBNA and the types of pulmonary arterial tumors and their different diagnostic modalities. We searched the Cochrane Library and PubMed from 2004 to 2014 to provide the most comprehensive review. Only 10 cases of EBUS-TBNA for intravascular lesions were identified in the literature. Although many cases of EBUS and EUS-guided transvascular tumor biopsies were described in the literature, there were no reported cases of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for intravascular tumor biopsies. Except for one paper, all cases were published as case reports.

  6. Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles.

    PubMed

    Antonini, Filippo; Fuccio, Lorenzo; Giorgini, Sara; Fabbri, Carlo; Frazzoni, Leonardo; Scarpelli, Marina; Macarri, Giampiero

    2017-08-01

    While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p=0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48h or ≥48h before EUS). No EUS-FNB related complications were recorded. The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  7. Cost-effectiveness of culture-guided antimicrobial prophylaxis for the prevention of infections after prostate biopsy.

    PubMed

    Li, Chi-Kong; Tong, Brian C Y; You, Joyce H S

    2016-02-01

    Clinical findings suggest that the use of rectal culture-guided antibiotic prophylaxis reduces the infection rate following transrectal ultrasound-guided prostate biopsy (TRUSBx). A decision-analytic model was designed to compare the outcomes of TRUSBx performed with (rectal culture-guided group) and without (standard ciprofloxacin prophylaxis) rectal swab culture-guided antimicrobial prophylaxis in Hong Kong. The post-biopsy infection rate, infection-related costs, quality-adjusted life years (QALYs) lost for infection, and incremental cost per QALY saved (ICER) were assessed. Model inputs were retrieved from local epidemiology data and the medical literature. A sensitivity analysis was performed to test the robustness of the model results. Base-case analysis showed that the infection rate in the culture-guided group was reduced from 2.42% to 0.23% and saved 0.0002 QALYs, with a lower cost (USD 31.4 versus USD 55.6) (USD 1=HKD 7.8). The number needed to screen to prevent an infection episode was 45.7. The hospital days avoided per 100 patients using culture-guided prophylaxis was 7.08 days. The relative effectiveness of culture-guided antimicrobial prophylaxis versus standard prophylaxis in carriers and non-carriers of FQ-resistant rectal flora were identified as potential influencing factors. In 10000 Monte Carlo simulations, ICERs of the culture-guided group were below the willingness-to-pay threshold 99.12% of the time. Using rectal culture-guided antimicrobial prophylaxis for men undergoing TRUSBx appears to be a cost-saving strategy to avert post-biopsy infection and QALY loss in Hong Kong. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. [Image fusion: use in the control of the distribution of prostatic biopsies].

    PubMed

    Mozer, Pierre; Baumann, Michaël; Chevreau, Grégoire; Troccaz, Jocelyne

    2008-02-01

    Prostate biopsies are performed under 2D TransRectal UltraSound (US) guidance by sampling the prostate according to a predefined pattern. Modern image processing tools allow better control of biopsy distribution. We evaluated the accuracy of a single operator performing a pattern of 12 ultrasound-guided biopsies by registering 3D ultrasound control images acquired after each biopsy. For each patient, prostate image alignment was performed automatically with a voxel-based registration algorithm allowing visualization of each biopsy trajectory in a single ultrasound reference volume. On average, the operator reached the target in 60% of all cases. This study shows that it is difficult to accurately reach targets in the prostate using 2D ultrasound. In the near future, real-time fusion of MRI and US images will allow selection of a target in previously acquired MR images and biopsy of this target by US guidance.

  9. Diffuse reflectance imaging: a tool for guided biopsy

    NASA Astrophysics Data System (ADS)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  10. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    PubMed Central

    Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre

    2011-01-01

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer. PMID:24212643

  11. Ultrasound-guided peripheral nerve blockade.

    PubMed

    Chin, Ki Jinn; Chan, Vincent

    2008-10-01

    The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.

  12. Comparative Effectiveness of Targeted Prostate Biopsy Using Magnetic Resonance Imaging Ultrasound Fusion Software and Visual Targeting: a Prospective Study.

    PubMed

    Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar

    2016-09-01

    We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance-ultrasound

  13. Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.

    PubMed

    Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S

    2014-07-01

    (1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  14. [Ultrasound-guided peripheral catheterization].

    PubMed

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  15. Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle

    PubMed Central

    Diederich, S; Padge, B; Vossas, U; Hake, R; Eidt, S

    2006-01-01

    Purpose: To assess feasibility, results and complications in image-guided biopsies using a single needle design in various organs. Materials and methods: 100 consecutive percutaneous biopsies were performed in 54 females and 46 males aged 24–87 years (mean age/standard deviation: 64.5 +/− 12 years) using a full-core end-cut tri-axial full-automatic biopsy needle (18 gauge BioPince ™, InterV-MDTech, Gainesville, Florida) under CT (n=45) or ultrasound (n=55) guidance. In 63 biopsies a coaxial technique was used. Results: Biopsies were obtained of liver (n=32), lymph nodes (n=17), thyroid (n=11), lung (n=9), adrenal (n=9), pelvis (n=6), chest wall/pleura (n=6), mediastinum (n=4), lytic bone lesions (n=2), retroperitoneum (n=1), muscle (n=1), pancreas (n=1), peritoneum (n=1). Between 1 and 6 (mean/SD 2.83 +/− 0.92) needle passes were performed. In 77 cases a malignant (40 metastases, 37 primary tumours) and in 23 a benign lesion was diagnosed. Of the 23 benign lesions a specific diagnosis was possible in 22. In one case necrosis and haemorrhage was diagnosed. In this patient surgery and autopsy both revealed a mediastinal haematoma of unknown origin. Eight minor complications (mild pain/local haematoma requiring no therapy) and three major complications (three pneumothoraces in nine lung biopsies requiring two aspirations and one drainage) were observed. There was no mortality. Conclusion: Percutaneous image-guided biopsy using the described full-core end-cut needle resulted in a specific diagnosis in 99/100 consecutive biopsies in various organs with a low complication rate. We use this needle type for all CT- or US-guided biopsies in all organs except for solid bone. PMID:16766268

  16. Transperineal template-guided prostate saturation biopsies in men with suspicion of prostate cancer: a pilot study from Pakistan.

    PubMed

    Mehmood, K; Mubarak, M; Dhar, M; Rafi, M; Kinsella, J

    2017-12-01

    Traditionally, transrectal ultrasound (TRUS)-guided biopsies are done for the diagnosis of prostate cancer (PCa) in Pakistan. The transperineal template-guided saturation biopsy (TTSB) approach has been recently introduced in Pakistan and we share diagnostic yields and pathological findings of specimens taken for PCa diagnosis in men with elevated serum total prostate specific antigen (PSA) and negative TRUS-guided prostate biopsies. In all, 16 patients investigated at the Department of Urology, Sindh Institute of Urology and Transplantation (SIUT), underwent TTSB. The mean age of patients was 67.8 ± 8.8 (range: 55 - 84) years. The median PSA was 9.5 (IQR: 7.9 - 19.8) ng/ ml. The duration of symptoms before biopsy ranged from 1 month to 144 months. The prostate was enlarged with mean weight of 73.5 ± 55.5 g. Histopathology revealed PCa in 5 of 16 (31.2%) cases. The Gleason score was 6 (3+3), 7 (3+4) and 8 (4+4) in 1 case each (6.3%) and 10 (5+5) in 2 cases (12.5%). At least two cores were positive in all positive cases. None of the patients required antibiotics post-procedure. In conclusion, the TTSB technique is a promising option for patients with elevated PSA level and negative transrectal prostate biopsies for the detection of PCa in our setting.

  17. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Peter R., E-mail: pmarti46@uwo.ca; Cool, Derek W.; Romagnoli, Cesare

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiologymore » resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for

  18. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    PubMed

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  19. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat

    2008-02-15

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsymore » procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced

  20. Robotic active positioning for magnetic resonance-guided high-intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Xiao, Xu; Huang, Zhihong; Volovick, Alexander; Melzer, Andreas

    2012-11-01

    Magnetic resonance (MR) guided High-intensity focused ultrasound (HIFU) is a noninvasive method producing thermal necrosis and cavitation at the position of tumors with high accuracy. Because the typical size of the high-intensity focused ultrasound focus are much smaller than the targeted tumor or other tissues, multiple sonications and focus repositioning become necessary for HIFU treatment. In order to reach a much wider range, manual repositioning or using MR compatible mechanical actuators could be used. The repositioning technique is a time consuming procedure because it needs a series of MR imaging to detect the transducer and markers preplaced on the mechanical devices. We combined an active tracking technique into the MR guided HIFU system. In this work, the robotic system used is the MR-compatible robotics from InnoMotion{trade mark, serif} (IBSMM, Engineering spol. s r.o. / Ltd, Czech) which is originally designed for MR-guided needle biopsy. The precision and positioning speed of the combined robotic HIFU system are evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the HIFU treatment to operate in a larger spatial range and with a faster speed.

  1. MRI/US fusion-guided prostate biopsy allows for equivalent cancer detection with significantly fewer needle cores in biopsy-naive men

    PubMed Central

    Yarlagadda, Vidhush K.; Lai, Win Shun; Gordetsky, Jennifer B.; Porter, Kristin K.; Nix, Jeffrey W.; Thomas, John V.; Rais-Bahrami, Soroush

    2018-01-01

    PURPOSE We aimed to investigate the efficiency and cancer detection of magnetic resonance imaging (MRI)/ultrasonography (US) fusion-guided prostate biopsy in a cohort of biopsy-naive men compared with standard-of-care systematic extended sextant transrectal ultrasonography (TRUS)-guided biopsy. METHODS From 2014 to 2016, 72 biopsy-naive men referred for initial prostate cancer evaluation who underwent MRI of the prostate were prospectively evaluated. Retrospective review was performed on 69 patients with lesions suspicious for malignancy who underwent MRI/US fusion-guided biopsy in addition to systematic extended sextant biopsy. Biometric, imaging, and pathology data from both the MRI-targeted biopsies and systematic biopsies were analyzed and compared. RESULTS There were no significant differences in overall prostate cancer detection when comparing MRI-targeted biopsies to standard systematic biopsies (P = 0.39). Furthermore, there were no significant differences in the distribution of severity of cancers based on grade groups in cases with cancer detection (P = 0.68). However, significantly fewer needle cores were taken during the MRI/US fusion-guided biopsy compared with systematic biopsy (63% less cores sampled, P < 0.001) CONCLUSION In biopsy-naive men, MRI/US fusion-guided prostate biopsy offers equal prostate cancer detection compared with systematic TRUS-guided biopsy with significantly fewer tissue cores using the targeted technique. This approach can potentially reduce morbidity in the future if used instead of systematic biopsy without sacrificing the ability to detect prostate cancer, particularly in cases with higher grade disease. PMID:29770762

  2. Motorized fusion guided prostate biopsy: phantom study

    NASA Astrophysics Data System (ADS)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.

    2017-03-01

    Purpose: Fusion of Magnetic Resonance Imaging (MRI) with intraoperative real-time Ultrasound (US) during prostate biopsy has significantly improved the sensitivity of transrectal ultrasound (TRUS) guided cancer detection. Currently, sweeping of the TRUS probe to build a 3D volume as part of the fusion process and the TRUS probe manipulation for needle guidance are both done manually. A motorized, joystick controlled, probe holder was custom fabricated that can potentially reduce inter-operator variability, provide standardization of needle placement, improve repeatability and uniformity of needle placement, which may have impacts upon the learning curve after clinical deployment of this emerging approach. Method: a 2DOF motorized probe holder was designed to provide translation and rotation of a triplane TRUS end firing probe for prostate biopsy. The probe holder was joystick controlled and can assist manipulation of the probe during needle insertion as well as in acquiring a smoother US 2D to 3D sweep in which the 3D US volume for fusion is built. A commercial MRI-US fusion platform was used. Three targets were specified on MR image of a commercial prostate phantom. After performing the registration, two operators performed targeting, once manually and once with the assistance of the motorized probe holder. They repeated these tasks 5 times resulting in a total of 30 targeting events. Time of completion and mechanical error i.e. distance of the target from the needle trajectory in the software user interface were measured. Repeatability in reaching a given target in a systematic and consistent way was measured using a scatter plot showing all targets in the US coordinate system. Pearson product-moment correlation coefficient (PPMCC) was used to demonstrate the probe steadiness during targeting. Results: the completion time was 25+/-17 sec, 25+/-24 sec, and 27+/-15 sec for free hand and 24+/-10 sec, 22.5+/-10 sec, and 37+/-10 sec for motorized insertion, for target

  3. Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis

    DTIC Science & Technology

    2012-06-01

    can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study are (1) light...which collect light scattering and auto-fluorescence from the prostate tissue, into a transrectal- ultrasound , needle - biopsy probe. In the...probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study were

  4. Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis

    DTIC Science & Technology

    2011-06-01

    integrated needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for... needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study...tissue, into a transrectal- ultrasound , needle - biopsy probe. In the development phase, documentation to obtain IRB approval for ex vivo human prostate

  5. Detection and clearance of prostate cells subsequent to ultrasound-guided needle biopsy as determined by multiplex nested reverse transcription polymerase chain reaction assay.

    PubMed

    Price, D K; Clontz, D R; Woodard, W L; Kaufman, J S; Daniels, J M; Stolzenberg, S J; Teigland, C M

    1998-08-01

    To determine if circulating prostate cells are detectable subsequent to transrectal ultrasound (TRUS)-guided biopsy, and if so, whether cells remain in circulation for up to 4 weeks. Blood samples were drawn from 90 patients with elevated serum prostate-specific antigen (PSA) levels and/or abnormal digital rectal examination. Two samples were drawn from all patients immediately prior to TRUS and 30 minutes postbiopsy. Blood samples were also obtained 1 week postbiopsy from 83 patients, and 1 month postbiopsy from 61 patients. Multiplex nested reverse transcription polymerase chain reaction assay (RT-PCR) for PSA and prostate-specific membrane antigen (PSM) was performed on total ribonucleic acid (RNA) from each sample. Results were reported as positive if at least one of the targets was detected. Of 45 patients with biopsy-proven adenocarcinoma, 22 were RT-PCR positive prebiopsy and all remained positive 30 minutes postbiopsy. Of 23 patients with adenocarcinoma who were RT-PCR negative prebiopsy, 5 (22%) converted to positive 30 minutes postbiopsy (P < 0.001). Four of these 5 patients returned to negative after 1 week or 1 month. Of 45 patients without cancer at biopsy, 32 were RT-PCR negative prebiopsy and 6 (19%) converted to positive 30 minutes postbiopsy (P < 0.001). Although four of six available samples were still positive at 1 week, all four samples available 1 month postbiopsy were negative. Detection of circulating prostate cells subsequent to biopsy occurred in 11 of 55 (20%) previously RT-PCR negative patients, a proportion twice that reported in the literature. We attribute this higher proportion to the simultaneous detection of PSA and PSM mRNA in our multiplex assay. Conversion rates were similar in patients regardless of biopsy result. Testing of serial postbiopsy blood demonstrates clearing of these cells by 4 weeks in most patients.

  6. Variability of transrectal ultrasound-guided prostate biopsy prophylactic measures.

    PubMed

    Hillelsohn, Joel H; Duty, Brian; Blute, Michael L; Okhunov, Zhamshid; Kashan, Mahyar; Moldwin, Robert; Ashley, Richard N

    2012-12-01

    To assess the variability of pre-prostate biopsy prophylaxis among American urologists. A survey was electronically mailed to 3355 urologists around the country. Urologists were surveyed on their antibiotic prophylaxis choice, the route and duration of antimicrobial prophylaxis. Additionally they were questioned about their knowledge of local antimicrobial resistance and if rectal enemas were routinely used. There were 679 (21%) responses to the survey. The survey revealed differences in pre-prostate biopsy prophylaxis among urologists. Ten different classes of antibiotics were used orally, 4 classes intramuscular, 5 classes intravenous, and there was also 14 different duration regimens. Despite the initiation of the 2008 American Urological Association Guidelines on this topic, there still is a lack of uniformity in prostate biopsy prophylaxis.

  7. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.

    PubMed

    Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki

    2017-03-01

    The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. Why and Where do We Miss Significant Prostate Cancer with Multi-parametric Magnetic Resonance Imaging followed by Magnetic Resonance-guided and Transrectal Ultrasound-guided Biopsy in Biopsy-naïve Men?

    PubMed

    Schouten, Martijn G; van der Leest, Marloes; Pokorny, Morgan; Hoogenboom, Martijn; Barentsz, Jelle O; Thompson, Les C; Fütterer, Jurgen J

    2017-06-01

    Knowledge of significant prostate (sPCa) locations being missed with magnetic resonance (MR)- and transrectal ultrasound (TRUS)-guided biopsy (Bx) may help to improve these techniques. To identify the location of sPCa lesions being missed with MR- and TRUS-Bx. In a referral center, 223 consecutive Bx-naive men with elevated prostate specific antigen level and/or abnormal digital rectal examination were included. Histopathologically-proven cancer locations, Gleason score, and tumor length were determined. All patients underwent multi-parametric MRI and 12-core systematic TRUS-Bx. MR-Bx was performed in all patients with suspicion of PCa on multi-parametric MRI (n=142). Cancer locations were compared between MR- and TRUS-Bx. Proportions were expressed as percentages, and the corresponding 95% confidence intervals were calculated. In total, 191 lesions were found in 108 patients with sPCa. From these lesion 74% (141/191) were defined as sPCa on either MR- or TRUS-Bx. MR-Bx detected 74% (105/141) of these lesions and 61% (86/141) with TRUS-Bx. TRUS-Bx detected more lesions compared with MR-Bx (140 vs 109). However, these lesions were often low risk (39%). Significant lesions missed with MR-Bx most often had involvement of dorsolateral (58%) and apical (37%) segments and missed segments with TRUS-Bx were located anteriorly (79%), anterior midprostate (50%), and anterior apex (23%). Both techniques have difficulties in detecting apical lesions. MR-Bx most often missed cancer with involvement of the dorsolateral part (58%) and TRUS-Bx with involvement of the anterior part (79%). Both biopsy techniques miss cancer in specific locations within the prostate. Identification of these lesions may help to improve these techniques. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  9. A serious game for learning ultrasound-guided needle placement skills.

    PubMed

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  10. High Frequency Ultrasound Array Designed for Ultrasound Guided Breast Biopsy

    PubMed Central

    Cummins, Thomas; Eliahoo, Payam; Shung, K. Kirk

    2016-01-01

    This paper describes the development of a miniaturized high frequency linear array that can be integrated within a core biopsy needle to improve tissue sampling accuracy during breast cancer biopsy procedures. The 64 element linear array has an element width of 14 μm, kerf width of 6 μm, element length of 1 mm and element thickness of 24 μm. The 2–2 array composite was fabricated using deep reactive ion etching of PMN-PT single crystal material. The array composite fabrication process as well as a novel high density electrical interconnect solution are presented and discussed. Array performance measurements show that the array had a center frequency and fractional bandwidth (−6 dB) of 59.1 MHz and 29.4%, respectively. Insertion loss and adjacent element cross talk at the center frequency were −41.0 dB and −23.7 dB, respectively. A B-mode image of a tungsten wire target phantom was captured using a synthetic aperture imaging system and the imaging test results demonstrate axial and lateral resolutions of 33.2 μm and 115.6 um, respectively. PMID:27046895

  11. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  12. Safety of pediatric percutaneous liver biopsy performed by interventional radiologists.

    PubMed

    Potter, Carol; Hogan, Mark J; Henry-Kendjorsky, Katherine; Balint, Jane; Barnard, John A

    2011-08-01

    National data suggest that pediatric percutaneous liver biopsy is increasingly being performed by interventional radiologists rather than pediatric gastroenterologists. The objective of the present report is to describe the safety and effectiveness of percutaneous liver biopsy performed by interventional radiologists in a large cohort of children and to compare the results with the existing literature on biopsies performed by pediatric gastroenterologists. The medical records of 249 children undergoing ultrasound-guided percutaneous liver biopsy by interventional radiologists were reviewed for adverse events and success of obtaining tissue. Two hundred ninety-four biopsies were reviewed. There were no deaths. There were 2 instances of a 2-g or greater drop in hemoglobin following biopsy, neither of which was associated with clinical signs of hemorrhage. A small, asymptomatic pneumothorax quickly resolved without treatment. One patient developed Klebsiella sepsis 48  hours after biopsy. In all but 1 case, an adequate sample size was obtained. This low incidence of adverse events compares favorably with existing published reports of morbidity and mortality following percutaneous liver biopsy performed by pediatric gastroenterologists. Ultrasound-guided percutaneous liver biopsy performed by experienced pediatric interventional radiologists in a children's hospital setting is as safe and effective as biopsy performed by pediatric gastroenterologists.

  13. Factors associated with success of image-guided tumour biopsies: Results from a prospective molecular triage study (MOSCATO-01).

    PubMed

    Tacher, Vania; Le Deley, Marie-Cécile; Hollebecque, Antoine; Deschamps, Frederic; Vielh, Philippe; Hakime, Antoine; Ileana, Ecaterina; Abedi-Ardekani, Behnoush; Charpy, Cécile; Massard, Christophe; Rosellini, Silvia; Gajda, Dorota; Celebic, Aljosa; Ferté, Charles; Ngo-Camus, Maud; Gouissem, Siham; Koubi-Pick, Valérie; Andre, Fabrice; Vassal, Gilles; Deandreis, Désirée; Lacroix, Ludovic; Soria, Jean-Charles; De Baère, Thierry

    2016-05-01

    MOSCATO-01 is a molecular triage trial based on on-purpose tumour biopsies to perform molecular portraits. We aimed at identifying factors associated with high tumour cellularity. Tumour cellularity (percentage of tumour cells in samples defined at pathology) was evaluated according to patient characteristics, target lesion characteristics, operators' experience and biopsy approach. Among 460 patients enrolled between November, 2011 and March, 2014, 334 patients (73%) had an image-guided needle biopsy of the primary tumour (N = 38) or a metastatic lesion (N = 296). Biopsies were performed on liver (N = 127), lung (N = 72), lymph nodes (N = 71), bone (N = 11), or another tumour site (N = 53). Eighteen patients (5%) experienced a complication: pneumothorax in 10 patients treated medically, and haemorrhage in 8, requiring embolisation in 3 cases. Median tumour cellularity was 50% (interquartile range, 30-70%). The molecular analysis was successful in 291/334 cases (87%). On-going chemotherapy, tumour origin (primary versus metastatic), lesion size, tumour growth rate, presence of necrosis on imaging, standardised uptake value, and needle size were not statistically associated with cellularity. Compared to liver or lung biopsies, cellularity was significantly lower in bone and higher in other sites (P < 0.0001). Cellularity significantly increased with the number of collected samples (P < 0.0001) and was higher in contrast-enhanced ultrasound-guided biopsies (P < 0.02). In paired samples, cellularity in central samples was lower than in peripheral samples in 85, equal in 68 and higher in 89 of the cases. Image-guided biopsy is feasible and safe in cancer patients for molecular screening. Imaging modality, multiple sampling of the lesion, and the organ chosen for biopsy were associated with higher tumour cellularity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Management of cystic or predominantly cystic thyroid nodules: the role of ultrasound-guided fine-needle aspiration biopsy.

    PubMed

    Bellantone, Rocco; Lombardi, Celestino Pio; Raffaelli, Marco; Traini, Emanuela; De Crea, Carmela; Rossi, Esther Diana; Fadda, Guido

    2004-01-01

    Conventional fine-needle aspiration biopsy (FNAB) for cystic thyroid nodules (CTNs) has a high rate of nondiagnostic and false-negative results. Ultrasound-guided FNAB (UG-FNAB) permits direct sampling of the wall and/or the solid portion of CTNs, increasing the possibility of a representative sample. In this study we evaluated the role of UG-FNAB in CTNs management. Five-hundred-seventy-five UG-FNAB of CTNs were performed. Thyroidectomy was carried out in 119 of these cases. The medical records of these 119 patients were reviewed and form the basis of this report. The nondiagnostic smear rate was 9.2%. Cytological diagnosis was benign nodule in 42 cases, predominantly follicular lesion in 50 cases, and suspicious or malignant lesion in 16 cases. The final pathology revealed a benign nodule in 98 cases (82.4%) and a carcinoma in 21 (17.6%). The overall accuracy of UG-FNAB was 88.0%. No significant differences were found in age, sex, lesion size, or echographic pattern (p = NS) comparing patients with benign CTNs to patients with malignant CTNs. UG-FNAB has a low rate of nondiagnostic smears and a high overall accuracy in CTNs. All CTNs should undergo UG-FNAB to select patients for surgery, since the malignancy rate is not negligible and no clinical parameter can reliably predict it.

  15. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less

  16. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    NASA Astrophysics Data System (ADS)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  17. Management of benign papilloma without atypia diagnosed at ultrasound-guided core needle biopsy: Scoring system for predicting malignancy.

    PubMed

    Ahn, Soo Kyung; Han, Wonshik; Moon, Hyeong-Gon; Kim, Min Kyoon; Noh, Dong-Young; Jung, Bong-Wha; Kim, Sung-Won; Ko, Eunyoung

    2018-01-01

    The management of benign intraductal papilloma diagnosed on core needle biopsy (CNB) remains unclear. This study was designed to evaluate factors predicting malignancy in patients diagnosed with benign papilloma without atypia at ultrasound-guided CNB and to develop a scoring system predicting malignancy based on clinical, radiological and pathological factors on further excisional biopsy. The study enrolled patients diagnosed with benign papillomas (including benign and atypical papillary lesions) at CNB. Multivariate analysis was used to identify relevant clinical, radiological and pathological factors that may predict malignancy. A total of 520 CNBs were diagnosed with benign or atypical papilloma. Of these, 452 were benign papilloma without atypia. Of the 250 lesions subsequently excised surgically from 234 women, 17 (6.8%) were diagnosed with malignancy. Multivariate analysis revealed that bloody nipple discharge, size on imaging ≥15 mm, BI-RADS≥4b, peripheral location and palpability were independent predictors of malignancy. A scoring system was developed based on logistic regression models and beta coefficients for each variable. The area under the ROC curve was 0.947 (95% CI: 0.913-0.981, p < 0.001) and a negative predictive value was 100%. In a validation set of 62 patients, an area under the ROC curve was 0.926 (95% CI: 0.857-0.995, p < 0.001). A scoring system predicting malignancy in patients diagnosed by CNB with benign papilloma without atypia was developed. This system was able to identify a subset of patients with lesions likely to be benign, indicating that imaging follow-up rather than surgical excision may be appropriate. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  18. MRI-guided Breast Biopsy: Outcomes and Impact on Patient Management

    PubMed Central

    Kamel, Ihab R; Macura, Katarzyna J

    2014-01-01

    Introduction The purpose of this study was to correlate the pathology results of magnetic resonance imaging (MRI)-guided breast biopsies at our institution to MRI findings and patient clinical history characteristics. The impact of MRI-guided breast biopsies on surgical management in patients with a new diagnosis of breast cancer was also assessed. Patients and Methods In this HIPAA-compliant study we retrospectively reviewed all MRI-guided breast biopsies performed 3/2006–5/2012. Clinical history, MRI features and pathology outcomes were reviewed. In patients undergoing breast MRI to evaluate extent of disease, any change in surgical management resulting from the MRI-guided biopsy was recorded. Statistical analysis included binary logistic regression and independent student’s t-test. Results Two-hundred fifteen lesions in 168 patients were included, of which 23 (10.7%) were malignant, 43 (20%) were high risk, and 149 (69.3%) were benign. No clinical characteristic was associated with malignancy in our cohort. MRI features associated with malignancy were: larger size (mean 2.6 cm versus 1.3 cm, p=0.046), washout kinetics (18% malignancy rate, p=0.02) and marked background parenchymal enhancement (40% malignancy rate, p-value <0.001 to 0.03). Nineteen (28%) of the 67 patients with a new diagnosis of breast cancer undergoing MRI-guided breast biopsy had a change in surgical management based on the biopsy result. Conclusions Malignancy rate was associated with lesion size, washout kinetics and marked background enhancement of the breast parenchyma but was not associated with any clinical history characteristics. Pre-operative MRI-guided breast biopsies changed surgical management in 28% of women with a new diagnosis of breast cancer. PMID:25499596

  19. Trans-rectal ultrasound visibility of prostate lesions identified by magnetic resonance imaging increases accuracy of image-fusion targeted biopsies.

    PubMed

    Ukimura, Osamu; Marien, Arnaud; Palmer, Suzanne; Villers, Arnauld; Aron, Manju; de Castro Abreu, Andre Luis; Leslie, Scott; Shoji, Sunao; Matsugasumi, Toru; Gross, Mitchell; Dasgupta, Prokar; Gill, Inderbir S

    2015-11-01

    To compare the diagnostic yield of targeted prostate biopsy using image-fusion of multi-parametric magnetic resonance (mp-MR) with real-time trans-rectal ultrasound (TRUS) for clinically significant lesions that are suspicious only on mp-MR versus lesions that are suspicious on both mp-MR and TRUS. Pre-biopsy MRI and TRUS were each scaled on a 3-point score: highly suspicious, likely, and unlikely for clinically significant cancer (sPCa). Using an MR-TRUS elastic image-fusion system (Koelis), a 127 consecutive patients with a suspicious clinically significant index lesion on pre-biopsy mp-MR underwent systematic biopsies and MR/US-fusion targeted biopsies (01/2010-09/2013). Biopsy histological outcomes were retrospectively compared with MR suspicion level and TRUS-visibility of the MR-suspicious lesion. sPCa was defined as biopsy Gleason score ≥7 and/or maximum cancer core length ≥5 mm. Targeted biopsies outperformed systematic biopsies in overall cancer detection rate (61 vs. 41 %; p = 0.007), sPCa detection rate (43 vs. 23 %; p = 0.0013), cancer core length (7.5 vs. 3.9 mm; p = 0.0002), and cancer rate per core (56 vs. 12 %; p < 0.0001), respectively. Highly suspicious lesions on mp-MR correlated with higher positive biopsy rate (p < 0.0001), higher Gleason score (p = 0.018), and greater cancer core length (p < 0.0001). Highly suspicious lesions on TRUS in corresponding to MR-suspicious lesion had a higher biopsy yield (p < 0.0001) and higher sPCa detection rate (p < 0.0001). Since majority of MR-suspicious lesions were also suspicious on TRUS, TRUS-visibility allowed selection of the specific MR-visible lesion which should be targeted from among the multiple TRUS suspicious lesions in each prostate. MR-TRUS fusion-image-guided biopsies outperformed systematic biopsies. TRUS-visibility of a MR-suspicious lesion facilitates image-guided biopsies, resulting in higher detection of significant cancer.

  20. Magnetic resonance imaging-transectal ultrasound image-fusion biopsies accurately characterize the index tumor: correlation with step-sectioned radical prostatectomy specimens in 135 patients.

    PubMed

    Baco, Eduard; Ukimura, Osamu; Rud, Erik; Vlatkovic, Ljiljana; Svindland, Aud; Aron, Manju; Palmer, Suzanne; Matsugasumi, Toru; Marien, Arnaud; Bernhard, Jean-Christophe; Rewcastle, John C; Eggesbø, Heidi B; Gill, Inderbir S

    2015-04-01

    Prostate biopsies targeted by elastic fusion of magnetic resonance (MR) and three-dimensional (3D) transrectal ultrasound (TRUS) images may allow accurate identification of the index tumor (IT), defined as the lesion with the highest Gleason score or the largest volume or extraprostatic extension. To determine the accuracy of MR-TRUS image-fusion biopsy in characterizing ITs, as confirmed by correlation with step-sectioned radical prostatectomy (RP) specimens. Retrospective analysis of 135 consecutive patients who sequentially underwent pre-biopsy MR, MR-TRUS image-fusion biopsy, and robotic RP at two centers between January 2010 and September 2013. Image-guided biopsies of MR-suspected IT lesions were performed with tracking via real-time 3D TRUS. The largest geographically distinct cancer focus (IT lesion) was independently registered on step-sectioned RP specimens. A validated schema comprising 27 regions of interest was used to identify the IT center location on MR images and in RP specimens, as well as the location of the midpoint of the biopsy trajectory, and variables were correlated. The concordance between IT location on biopsy and RP specimens was 95% (128/135). The coefficient for correlation between IT volume on MRI and histology was r=0.663 (p<0.001). The maximum cancer core length on biopsy was weakly correlated with RP tumor volume (r=0.466, p<0.001). The concordance of primary Gleason pattern between targeted biopsy and RP specimens was 90% (115/128; κ=0.76). The study limitations include retrospective evaluation of a selected patient population, which limits the generalizability of the results. Use of MR-TRUS image fusion to guide prostate biopsies reliably identified the location and primary Gleason pattern of the IT lesion in >90% of patients, but showed limited ability to predict cancer volume, as confirmed by step-sectioned RP specimens. Biopsies targeted using magnetic resonance images combined with real-time three-dimensional transrectal

  1. Women with peritoneal carcinomatosis of unknown origin: Efficacy of image-guided biopsy to determine site-specific diagnosis.

    PubMed

    Hewitt, M J; Anderson, K; Hall, G D; Weston, M; Hutson, R; Wilkinson, N; Perren, T J; Lane, G; Spencer, J A

    2007-01-01

    To evaluate the use of image-guided biopsy (IGB) in routine clinical practice to obtain site-specific diagnoses in women presenting with peritoneal carcinomatosis (PC). Retrospective case study. Tertiary referral centre. A total of 149 consecutive women with PC who underwent IGB. Biopsy was performed in women considered unsuitable for primary surgery because of poor performance status or disease unlikely to be optimally debulked, with a prior history of malignancy or where there was clinicoradiological uncertainty about primary tumour site. Standard haematoxylin-eosin histological analysis was supplemented with immunohistochemistry. The rate of site-specific diagnosis. A total of 149 women underwent IGB using computed tomography or ultrasound over a 6-year period. The only complication was one rectus sheath haematoma. In 138 (93%) women, a site-specific cancer diagnosis was made on the IGB (including 111 müllerian tract, 8 gastrointestinal tract, 4 breast and 3 lymphoma); in ten women, a repeat biopsy was necessary, giving an overall failure rate of 7%. In a further six women, malignancy was confirmed but a site-specific diagnosis could not be made, and in four women, biopsy showed benign tissue. A site-specific diagnosis was obtained in 29 of the 32 women (94%) with previous malignancy, of which 18/32 (56%) showed a new primary cancer. IGB is a safe and accurate technique for providing site-specific diagnoses in women with PC in routine clinical practice, including those with a previous relevant malignancy. IGB can replace laparoscopic or open biopsy in defining primary therapeutic options. The data would suggest that the biopsy should be performed with ultrasound where feasible.

  2. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    PubMed Central

    Spugnini, Enrico Pierluigi; Menicagli, Francesco; Pettorali, Michela; Baldi, Alfonso

    2017-01-01

    A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR). Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors. PMID:28331834

  3. EUS-guided biopsy for the diagnosis and classification of lymphoma.

    PubMed

    Ribeiro, Afonso; Pereira, Denise; Escalón, Maricer P; Goodman, Mark; Byrne, Gerald E

    2010-04-01

    EUS-guided FNA and Tru-cut biopsy (TCB) is highly accurate in the diagnosis of lymphoma. Subclassification, however, may be difficult in low-grade non-Hodgkin lymphoma and Hodgkin lymphoma. To determine the yield of EUS-guided biopsy to classify lymphoma based on the World Health Organization classification of tumors of hematopoietic lymphoid tissues. Retrospective study. Tertiary referral center. A total of 24 patients referred for EUS-guided biopsy who had a final diagnosis of lymphoma or "highly suspicious for lymphoma." EUS-guided FNA and TCB combined with flow cytometry (FC) analysis. MAIN OUTCOMES MEASUREMENT: Lymphoma subclassification accuracy of EUS guided biopsy. Twenty-four patients were included in this study. Twenty-three patients underwent EUS-FNA, and 1 patient had only TCB. Twenty-two underwent EUS-TCB combined with FNA. EUS correctly diagnosed lymphoma in 19 out of 24 patients (79%), and subclassification was determined in 16 patients (66.6%). Flow cytometry correctly identified B-cell monoclonality in 95% (18 out of 19). In 1 patient diagnosed as having marginal-zone lymphoma by EUS-FNA/FC only, the diagnosis was changed to hairy cell leukemia after a bone marrow biopsy was obtained. EUS had a lower yield in nonlarge B-cell lymphoma (only 9 out of 15 cases [60%]) compared with large B-cell lymphoma (78%; P = .3 [Fisher exact test]). Retrospective, small number of patients. EUS-guided biopsy has a lower yield to correctly classify Hodgkin lymphoma and low-grade lymphoma compared with high-grade diffuse large B-cell lymphoma. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  4. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  5. The detection and upgrade rates of prostate adenocarcinoma following transperineal template-guided prostate biopsy – a tertiary referral centre experience

    PubMed Central

    Telford, Robert; Viney, Richard; Patel, Prashant

    2016-01-01

    Introduction We aim to present transperineal template-guided prostate biopsy (template biopsy) outcomes at a tertiary referral centre. Furthermore, to identify the detection rate of prostate cancer in those with a previous negative transrectal ultrasound guided prostate biopsy and the upgrade rate of those on active surveillance for Gleason 3 + 3 = 6 prostate adenocarcinoma. Material and methods We conducted a prospective study of 200 consecutive men who underwent template biopsy over a 22-month period in a tertiary referral centre, using a standard 24 region template prostate biopsy technique. Indications and histology results, as well as complications, were recorded. Results Median age was 67 years and median PSA was 10 ng/mL. Overall detection rate was 47%. 39.5% of cases with previous negative transrectal biopsies were found to have prostate adenocarcinoma. 47.5% of cases on active surveillance for Gleason 3 + 3 = 6 prostate adenocarcinoma were upgraded. The most frequent complication was acute urinary retention at a rate of 12.5%, however, the use of a single prophylactic dose of tamsulosin was found to be beneficial, with 13 cases needed to treat to prevent one episode. Conclusions Template biopsies are safe and efficacious with an overall detection rate of 47% in the present series. Due to the high detection rate, one must consider template biopsy following one negative transrectal biopsy where there is persistent clinical suspicion. Furthermore, those considering active surveillance for Gleason 3 + 3 = 6 disease should be offered template biopsy to confirm the grade of their disease. PMID:27123325

  6. Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation.

    PubMed

    Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y

    2017-08-01

    To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.

  7. Comparative Effectiveness of Frame-based, Frameless and Intraoperative MRI Guided Brain Biopsy Techniques

    PubMed Central

    Lu, Yi; Yeung, Cecil; Radmanesh, Alireza; Wiemann, Robert; Black, Peter M.; Golby, Alexandra J.

    2015-01-01

    Objective Intraoperative MRI (IoMRI) guided brain biopsy provides a real time visual feedback of the lesion that is sampled during surgery. The objective of the study is to compare the diagnostic yield and safety profiles of ioMRI needle brain biopsy with two traditional brain biopsy methods: frame-based and frameless stereotactic brain biopsies. Methods A retrospective analysis from 288 consecutive needle brain biopsies in 277 patients undergoing stereotactic brain biopsy with any of the three biopsy methods at Brigham and Women's Hospital from 2000 to 2008 was performed. Variables such as age, sex, history of radiation and previous surgery, pathology results, complications and postoperative stays were analyzed. Results Over the course of eight years, 288 brain biopsies were performed. 253 (87.8%) biopsies yielded positive diagnostic tissue. Young age (<40 years), history of brain radiation or surgery were significant negative predictors for a positive biopsy diagnostic yield. Excluding patients with prior radiation or surgeries, no significant difference in diagnostic yield was detected among the three groups, with frame-based, frameless and ioMRI guided needle biopsies yield 96.9%, 91.8% and 89.9% positive diagnostic yield, respectively. 19 biopsies (6.6%) were complicated by serious adverse events. The ioMRI-guided brain biopsy was associated with less serious adverse events and the shortest postoperative hospital stay. Conclusions Frame-based, frameless stereotactic and ioMRI guided brain needle biopsy have comparable diagnostic yield for patients with no prior treatments (either radiation or surgery). IoMRI guided brain biopsy is associated with fewer serious adverse events and shorter hospital stay. PMID:25088233

  8. BiopSee® - transperineal stereotactic navigated prostate biopsy.

    PubMed

    Zogal, Pawel; Sakas, Georgios; Rösch, Woerner; Baltas, Dimos

    2011-06-01

    In the recent years, prostate cancer was the most commonly diagnosed cancer in men. Currently secure diagnosis confirmation is done by a transrectal biopsy and following histopathological examination. Conventional transrectal biopsy success rates are rather low with ca. 30% detection upon the first and ca 20% after re-biopsy. The paper presents a novel system for stereotactic navigated prostate biopsy. The approach results into higher accuracy, reproducibility and unrestricted and effective access to all prostate regions. Custom designed ultrasound, new template design and integrated 2-axes stepper allows superior 2D and 3D prostate imaging quality and precise needle navigation. DICOM functionality and image fusion enable to import pre-operative datasets (e.g. multiparametric MRI, targets etc.) and overlay all available radiological information into the biopsy planning and guiding procedure. The biopsy needle insertion itself is performed under augmented reality ultrasound guidance. Each procedure step is automatically documented in order to provide quality assurance and permit data re-usage for the further treatment. First clinical results indicates success rates of ca. 70% by first biopsies by our approach.

  9. Combination of Tramadol and Lidocaine for Pain Control During Transrectal Ultrasound-guided Prostate Biopsy: A Randomized Double-blinded Study.

    PubMed

    Sen, Haluk; Seckiner, Ilker; Bayrak, Omer; Sen, Elzem; Erturhan, Sakip; Yagci, Faruk

    2015-06-01

    To evaluate the efficacy of tramadol, lidocaine, and a combination of tramadol with lidocaine in pain relief using periprostatic nerve block technique by guidance of transrectal ultrasound (TRUS) before the prostate biopsy (PBx). For the indication of TRUS-PBx, the patients with a prostate-specific antigen (PSA) level >4.0 ng/mL or abnormal digital examination findings were selected. The patients were randomized through random method. Group 1: patients were administered 5 mL of 2% lidocaine; group 2: patients were administered 5 mL of 25-mg tramadol; and group 3: patients were administered 5 mL of 2% lidocaine + 25-mg tramadol. The procedures were completed in 10 minutes, and a visual pain scale was administered to the patients to question the pain severity. TRUS-guided PBx was performed in 60 patients with an age range of 57-77 years (mean age, 66.2 ± 7.49 years) and a PSA range of 1-1000 ng/mL. The mean PSA level of the groups was 28.5 (±7.5), 16.1 (±5.0), and 14.9 (±2.9) ng/mL, respectively. The postprocedural pain scores by visual pain scale were 4.6 ± 1.2, 5.4 ± 1.2, and 3.6 ± 0.9 in lidocaine, tramadol, and lidocaine + tramadol groups, respectively. Periprostatic nerve block is the current golden standard method owing to pain management and comfort provided, independent of the patient age and the number of core biopsies. We suggest that tramadol may also be used in this field to achieve better pain management by improving lidocaine's effect or as an alternative to lidocaine. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Application of Ultrasound-Guided Core Biopsy to Minimal-Invasively Diagnose Supraclavicular Fossa Tumors and Minimize the Requirement of Invasive Diagnostic Surgery

    PubMed Central

    Chen, Chun-Nan; Lin, Che-Yi; Chi, Fan-Hsiang; Chou, Chen-Han; Hsu, Ya-Ching; Kuo, Yen-Lin; Lin, Chih-Feng; Chen, Tseng-Cheng; Wang, Cheng-Ping; Lou, Pei-Jen; Ko, Jenq-Yuh; Hsiao, Tzu-Yu; Yang, Tsung-Lin

    2016-01-01

    Abstract Tumors of the supraclavicular fossa (SC) is clinically challenging because of anatomical complexity and tumor pathological diversity. Because of varied diseases entities and treatment choices of SC tumors, making the accurate decision among numerous differential diagnoses is imperative. Sampling by open biopsy (OB) remains the standard procedure for pathological confirmation. However, complicated anatomical structures of SC always render surgical intervention difficult to perform. Ultrasound-guided core biopsy (USCB) is a minimally invasive and office-based procedure for tissue sampling widely applied in many diseases of head and neck. This study aims to evaluate the clinical efficacy and utility of using USCB as the sampling method of SC tumors. From 2009 to 2014, consecutive patients who presented clinical symptoms and signs of supraclavicular tumors and were scheduled to receive sampling procedures for diagnostic confirmation were recruited. The patients received USCB or OB respectively in the initial tissue sampling. The accurate diagnostic rate based on pathological results was 90.2% for USCB, and 93.6% for OB. No significant difference was noted between USCB and OB groups in terms of diagnostic accuracy and the percentage of inadequate specimens. All cases in the USCB group had the sampling procedure completed within 10 minutes, but not in the OB group. No scars larger than 1 cm were found in USCB. Only patients in the OB groups had the need to receive general anesthesia and hospitalization and had scars postoperatively. Accordingly, USCB can serve as the first-line sampling tool for SC tumors with high diagnostic accuracy, minimal invasiveness, and low medical cost. PMID:26825877

  11. Infective complications in patients after transrectal ultrasound-guided prostate biopsy and the role of ciprofloxacin resistant Escherichia coli colonization in rectal flora.

    PubMed

    Hamarat, Mustafa Bilal; Tarhan, Fatih; Horuz, Rahim; Öcal, Gülfem Akengin; Demirkol, Mehmet Kutlu; Kafkaslı, Alper; Yazıcı, Özgür

    2017-06-01

    In the present study, we aimed to invastigate the ciprofloxacin resistance in rectal flora of the patients undergoing prostate biopsy in our department. Additionally, the possible effects of the presence of ciprofloxacin resistant bacteria in faecal flora on the risk of infective complications after the procedure as well as the effect of antibiotic prophylaxis on such infectious complications have been evaluated. A total of 142 patients undergoing transrectal ultrasound-guided prostate biopsy were included into the study program. Rectal swab samples were taken from all patients prior to biopsy. The presence of complications have been evaluated after a week following the biopsy procedure. Patients with fever were also evaluated. The possible correlation between the presence of ciprofloxacin-resistant bacteria in faecal flora and the risk of urinary tract infection development and the other complications were evaluated. E. coli bacteria were present in all cultures of rectal swab samples obtained from 142 patients prior to prostate biopsy. Of all these patients, while ciprofloxacin-resistant E. coli (CR E. coli ) grew in 76 (53.5%) patients; ciprofloxacin susceptible E. coli (CS E. coli ) was obtained in 66 (46.5%) patients. In 16 patients (11.3%), infectious complications were observed. While the infective complications were present in the 14.5% of patients with CR E. coli ; they were present in the 7.6% of patients with CS E. coli (p=0.295). High fever was observed in nine patients (6.3%). Of these nine patients, although six had CR E. coli growth as detected during culture sensitivity tests; three had CS E. coli growth in their rectal swab culture tests. Sepsis was observed in three (2.1%) of these patients with high fever. Ciprofloxacin-resistant E. coli grew in all of the rectal swab cultures obtained from these patients with sepsis. In the light of our findings we may say that, it will be appropriate to reconsider the ciprofloxacin prophylaxis and prefer to use

  12. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    PubMed

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  13. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  14. CT-Guided Percutaneous Biopsy of Intrathoracic Lesions

    PubMed Central

    Lal, Hira; Nath, Alok; Borah, Samudra

    2012-01-01

    Percutaneous CT-guided needle biopsy of mediastinal and pulmonary lesions is a minimally invasive approach for obtaining tissue for histopathological examination. Although it is a widely accepted procedure with relatively few complications, precise planning and detailed knowledge of various aspects of the biopsy procedure is mandatory to avert complications. In this pictorial review, we reviewed important anatomical approaches, technical aspects of the procedure, and its associated complications. PMID:22438689

  15. Right atrial and right ventricular ultrasound-guided biopsy technique in standing horses.

    PubMed

    Decloedt, A; de Clercq, D; Ven, S; van der Vekens, N; Chiers, K; van Loon, G

    2016-05-01

    Endomyocardial biopsies could be a valuable tool in equine cardiology for diagnosing myocardial disease, which is probably underdiagnosed in horses because of lack of specific diagnostic measures and limitations of currently available diagnostic methods. To describe a technique for serial right atrial and right ventricular endomyocardial biopsy in standing horses using a percutaneous approach through the jugular vein. Prospective study. Biopsy was performed in 10 healthy standing horses sedated with detomidine, under continuous electrocardiography monitoring. A 10 cm (n = 6), 45 cm (n = 1) or 98 cm (n = 3) introducer sheath was inserted into the right jugular vein. Under echocardiographic guidance, a biopsy forceps was introduced through the sheath into the right ventricle and right atrium and endomyocardial biopsies were acquired. In all horses, 3 right ventricular biopsies were obtained from the right ventricular apex and 3 right atrial biopsies were obtained from the dorsal right atrial wall near the tuberculum intervenosum. The presence of myocardial tissue was confirmed by histology. All horses showed atrial and ventricular premature depolarisations associated with acquisition of the biopsies. In 9 horses, the arrhythmia disappeared after retraction of the forceps and introducer sheath. In one horse, ventricular premature depolarisations disappeared only after 8 h. No other complications were observed. Endomyocardial biopsy of the right atrium and right ventricle could be performed in standing horses using a percutaneous approach through the jugular vein and was not associated with complications other than temporary arrhythmias. This technique may be useful for research purposes or as a diagnostic tool, although further research is needed to establish the safety of the technique in clinical patients with myocardial disease. © 2015 EVJ Ltd.

  16. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  17. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    PubMed

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  18. Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.

    PubMed

    Zamecnik, Patrik; Schouten, Martijn G; Krafft, Axel J; Maier, Florian; Schlemmer, Heinz-Peter; Barentsz, Jelle O; Bock, Michael; Fütterer, Jurgen J

    2014-12-01

    To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 μg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence. © RSNA, 2014.

  19. Systematic ultrasound-guided saturation and template biopsy of the prostate: indications and advantages of extended sampling.

    PubMed

    Isbarn, Hendrik; Briganti, Alberto; De Visschere, Pieter J L; Fütterer, Jurgen J; Ghadjar, Pirus; Giannarini, Gianluca; Ost, Piet; Ploussard, Guillaume; Sooriakumaran, Prasanna; Surcel, Christian I; van Oort, Inge M; Yossepowitch, Ofer; van den Bergh, Roderick C N

    2015-04-01

    Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. A non-systematic review of the literature was performed from 2000 through 2013. Studies of highest evidence (randomized controlled trials, prospective non-randomized studies, and retrospective reports of high quality) comparing standard vs saturation schemes on initial and repeat PB were evaluated. Outcome measures were overall PCa detection rate, detection rate of insignificant PCa, and procedure-associated morbidity. On initial PB, there is growing evidence that a saturation scheme is associated with a higher PCa detection rate compared to a standard one in men with lower PSA levels (<10 ng/ml), larger prostates (>40 cc), or lower PSA density values (<0.25 ng/ml/cc). However, these cut-offs are not uniform and differ among studies. Detection rates of insignificant PCa do not differ in a significant fashion between standard and saturation biopsies. On repeat PB, PCa detection rate is likewise higher with saturation protocols. Estimates of insignificant PCa vary widely due to differing definitions of insignificant disease. However, the rates of insignificant PCa appear to be comparable for the schemes in patients with only one prior negative biopsy, while saturation biopsy seems to detect more cases of insignificant PCa compared to standard biopsy in men with two or more prior negative biopsies. Very extensive sampling is associated with a high rate of acute urinary retention, whereas other severe adverse events, such as sepsis, appear not to occur more frequently with saturation schemes. Current evidence suggests that saturation schemes are associated with a higher PCa detection rate compared to standard ones on initial PB in men with lower PSA levels or larger prostates, and on repeat PB. Since

  20. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    PubMed

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  1. 2D-3D rigid registration to compensate for prostate motion during 3D TRUS-guided biopsy.

    PubMed

    De Silva, Tharindu; Fenster, Aaron; Cool, Derek W; Gardi, Lori; Romagnoli, Cesare; Samarabandu, Jagath; Ward, Aaron D

    2013-02-01

    Three-dimensional (3D) transrectal ultrasound (TRUS)-guided systems have been developed to improve targeting accuracy during prostate biopsy. However, prostate motion during the procedure is a potential source of error that can cause target misalignments. The authors present an image-based registration technique to compensate for prostate motion by registering the live two-dimensional (2D) TRUS images acquired during the biopsy procedure to a preacquired 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. The authors implemented an intensity-based 2D-3D rigid registration algorithm optimizing the normalized cross-correlation (NCC) metric using Powell's method. The 2D TRUS images acquired during the procedure prior to biopsy gun firing were registered to the baseline 3D TRUS image acquired at the beginning of the procedure. The accuracy was measured by calculating the target registration error (TRE) using manually identified fiducials within the prostate; these fiducials were used for validation only and were not provided as inputs to the registration algorithm. They also evaluated the accuracy when the registrations were performed continuously throughout the biopsy by acquiring and registering live 2D TRUS images every second. This measured the improvement in accuracy resulting from performing the registration, continuously compensating for motion during the procedure. To further validate the method using a more challenging data set, registrations were performed using 3D TRUS images acquired by intentionally exerting different levels of ultrasound probe pressures in order to measure the performance of our algorithm when the prostate tissue was intentionally deformed. In this data set, biopsy scenarios were simulated by extracting 2D frames from the 3D TRUS images and registering them to the baseline 3D image. A graphics processing unit (GPU)-based implementation was used to improve the

  2. [Ultrasound guided percutaneous nephrolithotripsy].

    PubMed

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  3. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement ofmore » the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.« less

  4. The Role of Ultrasound Compared to Biopsy of Temporal Arteries in the Diagnosis and Treatment of Giant Cell Arteritis (TABUL): a diagnostic accuracy and cost-effectiveness study.

    PubMed

    Luqmani, Raashid; Lee, Ellen; Singh, Surjeet; Gillett, Mike; Schmidt, Wolfgang A; Bradburn, Mike; Dasgupta, Bhaskar; Diamantopoulos, Andreas P; Forrester-Barker, Wulf; Hamilton, William; Masters, Shauna; McDonald, Brendan; McNally, Eugene; Pease, Colin; Piper, Jennifer; Salmon, John; Wailoo, Allan; Wolfe, Konrad; Hutchings, Andrew

    2016-11-01

    Giant cell arteritis (GCA) is a relatively common form of primary systemic vasculitis, which, if left untreated, can lead to permanent sight loss. We compared ultrasound as an alternative diagnostic test with temporal artery biopsy, which may be negative in 9-61% of true cases. To compare the clinical effectiveness and cost-effectiveness of ultrasound with biopsy in diagnosing patients with suspected GCA. Prospective multicentre cohort study. Secondary care. A total of 381 patients referred with newly suspected GCA. Sensitivity, specificity and cost-effectiveness of ultrasound compared with biopsy or ultrasound combined with biopsy for diagnosing GCA and interobserver reliability in interpreting scan or biopsy findings. We developed and implemented an ultrasound training programme for diagnosing suspected GCA. We recruited 430 patients with suspected GCA. We analysed 381 patients who underwent both ultrasound and biopsy within 10 days of starting treatment for suspected GCA and who attended a follow-up assessment (median age 71.1 years; 72% female). The sensitivity of biopsy was 39% [95% confidence interval (CI) 33% to 46%], which was significantly lower than previously reported and inferior to ultrasound (54%, 95% CI 48% to 60%); the specificity of biopsy (100%, 95% CI 97% to 100%) was superior to ultrasound (81%, 95% CI 73% to 88%). If we scanned all suspected patients and performed biopsies only on negative cases, sensitivity increased to 65% and specificity was maintained at 81%, reducing the need for biopsies by 43%. Strategies combining clinical judgement (clinician's assessment at 2 weeks) with the tests showed sensitivity and specificity of 91% and 81%, respectively, for biopsy and 93% and 77%, respectively, for ultrasound; cost-effectiveness (incremental net monetary benefit) was £485 per patient in favour of ultrasound with both cost savings and a small health gain. Inter-rater analysis revealed moderate agreement among sonographers (intraclass

  5. Sedoanalgesia With Midazolam and Fentanyl Citrate Controls Probe Pain During Prostate Biopsy by Transrectal Ultrasound

    PubMed Central

    Tsuji, Fábio Hissachi; Chambó, Renato Caretta; Agostinho, Aparecido Donizeti; Trindade Filho, José Carlos Souza

    2014-01-01

    Purpose To assess the pain intensity of patients administered midazolam and fentanyl citrate before undergoing transrectal ultrasound-guided prostate biopsy. Materials and Methods This was a study in patients with different indications for prostate biopsy in whom 5 mg of midazolam and 50 µg of fentanyl citrate was administered intravenously 3 minutes before the procedure. After biopsy, pain was assessed by use of a visual analogue scale (VAS) in three stages: VAS 1, during probe introduction; VAS 2, during needle penetration into prostate tissue; and VAS 3, in the weeks following the exam. Pain intensity at these different times was tested with stratification by age, race, education, prostate volume, rebiopsy, and anxiety before biopsy. Pain was ranked according to the following scores: 0 (no pain), 1-3 (mild pain), 4-7 (moderate pain), and 8-10 (severe pain). Statistical analysis was performed by using Kruskal-Wallis and Wilcoxon two-tailed tests with a significance of 5%. Results Pain intensity was not influenced by any risk factors. The mean VAS 1 score was 1.95±1.98, the mean VAS 2 score was 2.73±2.55, and the mean VAS 3 score was 0.3±0.9, showing greater pain at the time of needle penetration than in other situations (VAS 2>VAS 1>VAS 3, p=0.0013, p=0.0001, respectively). Seventy-five percent of patients reported a VAS pain scale of less than 3.1 or mild pain. Conclusions Intravenous sedation and analgesia with midazolam and fentanyl citrate is a good method for reducing pain caused by prostate biopsy, even during probe insertion. PMID:24578806

  6. Association of quantitative magnetic resonance imaging parameters with histological findings from MRI/ultrasound fusion prostate biopsy.

    PubMed

    Dianat, Seyed Saeid; Carter, H Ballentine; Schaeffer, Edward M; Hamper, Ulrik M; Epstein, Jonathan I; Macura, Katarzyna J

    2015-10-01

    Purpose of this pilot study was to correlate quantitative parameters derived from the multiparametric magnetic resonance imaging (MP-MRI) of the prostate with results from MRI guided transrectal ultrasound (MRI/TRUS) fusion prostate biopsy in men with suspected prostate cancer. Thirty-nine consecutive patients who had 3.0T MP-MRI and subsequent MRI/TRUS fusion prostate biopsy were included and 73 MRI-identified targets were sampled by 177 cores. The pre-biopsy MP-MRI consisted of T2-weighted, diffusion weighted (DWI), and dynamic contrast enhanced (DCE) images. The association of quantitative MRI measurements with biopsy histopathology findings was assessed by Mann-Whitney U- test and Kruskal-Wallis test. Of 73 targets, biopsy showed benign prostate tissue in 46 (63%), cancer in 23 (31.5%), and atypia/high grade prostatic intraepithelial neoplasia in four (5.5%) targets. The median volume of cancer-positive targets was 1.3 cm3. The cancer-positive targets were located in the peripheral zone (56.5%), transition zone (39.1%), and seminal vesicle (4.3%). Nine of 23 (39.1%) cancer-positive targets were higher grade cancer (Gleason grade > 6). Higher grade targets and cancer-positive targets compared to benign lesions exhibited lower mean apparent diffusion coefficient (ADC) value (952.7 < 1167.9 < 1278.9), and lower minimal extracellular volume fraction (ECF) (0.13 < 0.185 < 0.213), respectively. The difference in parameters was more pronounced between higher grade cancer and benign lesions. Our findings from a pilot study indicate that quantitative MRI parameters can predict malignant histology on MRI/TRUS fusion prostate biopsy, which is a valuable technique to ensure adequate sampling of MRI-visible suspicious lesions under TRUS guidance and may impact patient management. The DWI-based quantitative measurement exhibits a stronger association with biopsy findings than the other MRI parameters.

  7. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma--results in 103 biopsies.

    PubMed

    Vandervelde, C; Kamani, T; Varghese, A; Ramesar, K; Grace, R; Howlett, D C

    2008-04-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  8. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    PubMed

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  9. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    PubMed

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions < 10 mm (7.2%) (P < .01) but without statistically significant differences among the 3 gauges (P > .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017

  10. Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.

    PubMed

    Li, Zong Ming; Wu, Gang; Han, Xin Wei; Ren, Ke Wei; Zhu, Ming

    2014-01-01

    We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy.

  11. Radiology-guided forceps biopsy and airway stenting in severe airway stenosis

    PubMed Central

    Li, Zong-Ming; Wu, Gang; Han, Xin-Wei; Ren, Ke-Wei; Zhu, Ming

    2014-01-01

    PURPOSE We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. MATERIALS AND METHODS This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. RESULTS The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. CONCLUSION Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy. PMID:24808434

  12. Optimization of real-time rigid registration motion compensation for prostate biopsies using 2D/3D ultrasound

    NASA Astrophysics Data System (ADS)

    Gillies, Derek J.; Gardi, Lori; Zhao, Ren; Fenster, Aaron

    2017-03-01

    During image-guided prostate biopsy, needles are targeted at suspicious tissues to obtain specimens that are later examined histologically for cancer. Patient motion causes inaccuracies when using MR-transrectal ultrasound (TRUS) image fusion approaches used to augment the conventional biopsy procedure. Motion compensation using a single, user initiated correction can be performed to temporarily compensate for prostate motion, but a real-time continuous registration offers an improvement to clinical workflow by reducing user interaction and procedure time. An automatic motion compensation method, approaching the frame rate of a TRUS-guided system, has been developed for use during fusion-based prostate biopsy to improve image guidance. 2D and 3D TRUS images of a prostate phantom were registered using an intensity based algorithm utilizing normalized cross-correlation and Powell's method for optimization with user initiated and continuous registration techniques. The user initiated correction performed with observed computation times of 78 ± 35 ms, 74 ± 28 ms, and 113 ± 49 ms for in-plane, out-of-plane, and roll motions, respectively, corresponding to errors of 0.5 ± 0.5 mm, 1.5 ± 1.4 mm, and 1.5 ± 1.6°. The continuous correction performed significantly faster (p < 0.05) than the user initiated method, with observed computation times of 31 ± 4 ms, 32 ± 4 ms, and 31 ± 6 ms for in-plane, out-of-plane, and roll motions, respectively, corresponding to errors of 0.2 ± 0.2 mm, 0.6 ± 0.5 mm, and 0.8 ± 0.4°.

  13. Evaluation of the ESUR PI-RADS scoring system for multiparametric MRI of the prostate with targeted MR/TRUS fusion-guided biopsy at 3.0 Tesla.

    PubMed

    Roethke, M C; Kuru, T H; Schultze, S; Tichy, D; Kopp-Schneider, A; Fenchel, M; Schlemmer, H-P; Hadaschik, B A

    2014-02-01

    To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy. Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann-Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated. In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42%) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/Specificity for the following thresholds were calculated: 85 %/73 % and 67 %/92 % for PI-RADS scores of 9 and 10, respectively; 85 %/60 % and 56 %/97 % for Likert scores of 3 and 4, respectively [corrected. The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score. • The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. • To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. • PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. • Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. • The PI-RADS scoring system may contribute to more effective prostate MRI.

  14. A fatal case of hemoperitoneum after ultrasound-guided liver biopsy in a patient with intravascular large B-cell lymphoma.

    PubMed

    Aoki, Yasuhiro; Takamiya, Masataka; Satoh, Takashi; Fujita, Sachiko; Kato, Hideaki; Maeno, Yoshitaka

    2011-07-01

    An autopsy case of fatal complication of percutaneous liver biopsy targeting a rare type of large B-cell lymphoma is presented. A 79 year-old man was referred to the hematology unit of a hospital because of anemia with thrombocytopenia and hepatosplenomegaly. Results of inguinal lymph node biopsy were inconclusive. To investigate a mass lesion in the liver visualized by ultrasonography, image-guided liver biopsy was performed following platelet infusion. The patient became unresponsive 6h post procedure because of hypotension due to intraperitoneal hemorrhage of undetermined origin. Autopsy revealed hemoperitoneum but failed to identify any macroscopic intra- or extrahepatic vascular injuries. Histopathological investigation disclosed infiltration of atypical lymphocytes into the systemic organs including the lymph nodes, spleen, liver, and lungs. Prominent hemophagocytosis was also noted. The lymphoma cells were exclusively accumulated within vascular and sinusoidal structures, and diagnosed with immunohistochemistry as Asian variant of intravascular large B-cell lymphoma. Massive blood extravasation was presumed to originate directly from the markedly dilated liver sinusoids filled with erythrocytes, macrophages and tumor cells, under the condition of impaired hemostasis. Although the biopsy was thought to have been correctly performed, this case would be instructive for evaluation of the indications and risks associated with liver biopsy. 2011 Elsevier Ireland Ltd. All rights reserved.

  15. The Clinical Usefulness of Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy for Rectal and Perirectal Lesions

    PubMed Central

    Soh, Jae Seung; Lee, Ho-Su; Lee, Seohyun; Bae, Jungho; Lee, Hyo Jeong; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho

    2015-01-01

    Background/Aims Endoscopic ultrasound-guided fine needle aspiration and/or biopsy (EUS-FNA/B) have been used to diagnose subepithelial tumors (SETs) and extraluminal lesions in the gastrointestinal tract. Our group previously reported the usefulness of EUS-FNA/B for rectal and perirectal lesions. This study reports our expanded experience with EUS-FNA/B for rectal and perirectal lesions in terms of diagnostic accuracy and safety. We also included our new experience with EUS-FNB using the recently introduced ProCore needle. Methods From April 2009 to March 2014, EUS-FNA/B for rectal and perirectal lesions was performed in 30 consecutive patients. We evaluated EUS-FNA/B performance by comparing histological diagnoses with final results. We also investigated factors affecting diagnostic accuracy. Results Among 10 patients with SETs, EUS-FNA/B specimen results revealed a gastrointestinal stromal tumor in 4 patients and malignant lymphoma in 1 patient. The diagnostic accuracy of EUS-FNA/B was 50% for SETs (5/10). Among 20 patients with non-SET lesions, 8 patients were diagnosed with malignant disease and 7 were diagnosed with benign disease based on both EUS-FNA/B and the final results. The diagnostic accuracy of EUS-FNA/B for non-SET lesions was 75% (15/20). The size of lesions was the only factor related to diagnostic accuracy (P=0.027). Two complications of mild fever and asymptomatic pneumoperitoneum occurred after EUS-FNA/B. Conclusions The overall diagnostic accuracy of EUS-FNA/B for rectal and perirectal lesions was 67% (20/30). EUS-FNA/B is a clinically useful method for cytological and histological diagnoses of rectal and perirectal lesions. PMID:25931998

  16. Ultrasound in Radiology: from Anatomic, Functional, Molecular Imaging to Drug Delivery and Image-Guided Therapy

    PubMed Central

    Klibanov, Alexander L.; Hossack, John A.

    2015-01-01

    During the past decade, ultrasound has expanded medical imaging well beyond the “traditional” radiology setting - a combination of portability, low cost and ease of use makes ultrasound imaging an indispensable tool for radiologists as well as for other medical professionals who need to obtain imaging diagnosis or guide a therapeutic intervention quickly and efficiently. Ultrasound combines excellent ability for deep penetration into soft tissues with very good spatial resolution, with only a few exceptions (i.e. those involving overlying bone or gas). Real-time imaging (up to hundreds and thousands frames per second) enables guidance of therapeutic procedures and biopsies; characterization of the mechanical properties of the tissues greatly aids with the accuracy of the procedures. The ability of ultrasound to deposit energy locally brings about the potential for localized intervention encompassing: tissue ablation, enhancing penetration through the natural barriers to drug delivery in the body and triggering drug release from carrier micro- and nanoparticles. The use of microbubble contrast agents brings the ability to monitor and quantify tissue perfusion, and microbubble targeting with ligand-decorated microbubbles brings the ability to obtain molecular biomarker information, i.e., ultrasound molecular imaging. Overall, ultrasound has become the most widely used imaging modality in modern medicine; it will continue to grow and expand. PMID:26200224

  17. Direct comparison of the diagnostic yield of ultrasound-assisted Abrams and Tru-Cut needle biopsies for pleural tuberculosis.

    PubMed

    Koegelenberg, Coenraad Frederik N; Bolliger, Christoph Thomas; Theron, Johan; Walzl, Gerhard; Wright, Colleen Anne; Louw, Mercia; Diacon, Andreas Henri

    2010-10-01

    Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles. This prospective study compared ultrasound-assisted Abrams and Tru-Cut needle biopsies with regard to their diagnostic yield for pleural tuberculosis. 89 patients (54 men) of mean ± SD age 38.7 ± 16.7 years with pleural effusions and a clinical suspicion of tuberculosis were enrolled in the study. Transthoracic ultrasound was performed on all patients, who were then randomly assigned to undergo ≥ 4 Abrams needle biopsies followed by ≥ 4 Tru-Cut needle biopsies or vice versa. Medical thoracoscopy was performed on cases with non-diagnostic closed biopsies. Histological and/or microbiological proof of tuberculosis on any pleural specimen was considered the gold standard for pleural tuberculosis. Pleural tuberculosis was diagnosed in 66 patients, alternative diagnoses were established in 20 patients and 3 remained undiagnosed. Pleural biopsy specimens obtained with Abrams needles contained pleural tissue in 81 patients (91.0%) and were diagnostic for tuberculosis in 54 patients (sensitivity 81.8%), whereas Tru-Cut needle biopsy specimens only contained pleural tissue in 70 patients (78.7%, p=0.015) and were diagnostic in 43 patients (sensitivity 65.2%, p=0.022). Ultrasound-assisted pleural biopsies performed with an Abrams needle are more likely to contain pleura and have a significantly higher diagnostic sensitivity for pleural tuberculosis.

  18. Changing attitudes toward needle biopsies of breast cancer in Shanghai: experience and current status over the past 8 years

    PubMed Central

    Hao, Shuang; Liu, Zhe-Bin; Ling, Hong; Chen, Jia-Jian; Shen, Ju-Ping; Yang, Wen-Tao; Shao, Zhi-Min

    2015-01-01

    Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were selected from the Shanghai Cancer Data base, which integrates information from approximately 50% of breast cancer patients in Shanghai. The CNB procedure uses an automated prone unit, biopsy gun, and 14-gauge needles under freehand or ultrasound guidance and was performed by experienced radiologists and surgeons specializing in needle biopsies. Diagnosis and classification for each patient were independently evaluated by pathologists. Over the indicated 8-year period, biopsy type consisted of 11,947 ultrasound-guided core needle biopsies (UCNBs), 2,015 ultrasound-guided vacuum-assisted biopsies (UVABs), and 654 stereotactic X-ray-guided vacuum-assisted biopsies (XVABs). For all the 11,947 women included in this study, image-guided needle biopsy was the initial diagnostic procedure. Approximately 81.0% of biopsied samples were histopathologically determined to be malignant lesions, 5.5% were determined to be high-risk lesions, and 13.5% were determined to be benign lesions. The number of patients choosing UCNB increased at the greatest rate, and UCNB has become a standard procedure for histodiagnosis because it is inexpensive, convenient, and accurate. The overall false-negative rate of CNB was 1.7%, and the specific false-negative rates for UCNB, UVAB, and XVAB, were 1.7%, 0%, and 0%, respectively. This study suggests that the use of preoperative needle biopsy as the initial breast cancer diagnostic procedure is acceptable in urban Shanghai. Preoperative needle biopsy is now a standard procedure in the Shanghai Cancer Center because it may reduce the number of surgeries

  19. Endoscopic ultrasound-guided fine needle core biopsy for the diagnosis of pancreatic malignant lesions: a systematic review and Meta-Analysis

    PubMed Central

    Yang, Yongtao; Li, Lianyong; Qu, Changmin; Liang, Shuwen; Zeng, Bolun; Luo, Zhiwen

    2016-01-01

    Endoscopic ultrasound-guided fine needle core biopsy (EUS-FNB) has been used as an effective method of diagnosing pancreatic malignant lesions. It has the advantage of providing well preserved tissue for histologic grading and subsequent molecular biological analysis. In order to estimate the diagnostic accuracy of EUS-FNB for pancreatic malignant lesions, studies assessing EUS-FNB to diagnose solid pancreatic masses were selected via Medline. Sixteen articles published between 2005 and 2015, covering 828 patients, met the inclusion criteria. The summary estimates for EUS-FNB differentiating malignant from benign solid pancreatic masses were: sensitivity 0.84 (95% confidence interval (CI), 0.82–0.87); specificity 0.98 (95% CI, 0.93–1.00); positive likelihood ratio 8.0 (95% CI 4.5–14.4); negative likelihood ratio 0.17 (95% CI 0.10–0.26); and DOR 64 (95% CI 30.4–134.8). The area under the sROC curve was 0.96. Subgroup analysis did not identify other factors that could substantially affect the diagnostic accuracy, such as the study design, location of study, number of centers, location of lesion, whether or not a cytopathologist was present, and so on. EUS-FNB is a reliable diagnostic tool for solid pancreatic masses and should be especially considered for pathology where histologic morphology is preferred for diagnosis. PMID:26960914

  20. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    NASA Astrophysics Data System (ADS)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  1. Single-Institution Results of Image-Guided Nonplugged Percutaneous Versus Transjugular Liver Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardman, Rulon L., E-mail: hardmanr@uthscsa.edu; Perrich, Kiley D.; Silas, Anne M.

    2011-04-15

    Purpose: To retrospectively review patients who underwent transjugular and image-guided percutaneous biopsy and compare the relative risk of ascites, thrombocytopenia, and coagulopathy. Materials and Methods: From August 2001 through February 2006, a total of 238 liver biopsies were performed. The radiologist reviewed all patient referrals for transjugular biopsy. These patients either underwent transjugular biopsy or were reassigned to percutaneous biopsy (crossover group). Patients referred to percutaneous image-guided liver biopsy underwent this same procedure. Biopsies were considered successful if a tissue diagnosis could be made from the samples obtained. Results: A total of 36 transjugular biopsies were performed with 3 totalmore » (8.3%) and 1 major (2.8%) complications. A total of 171 percutaneous biopsies were performed with 10 (5.8%) total and 3 (1.8%) major complications. The crossover group showed a total of 4 (12.9%) complications with 1 (3.2%) major complication. Sample adequacy was 91.9% for transjugular and 99.5% for percutaneous biopsy. Conclusion: Both transjugular and percutaneous liver biopsy techniques are efficacious and safe. Contraindications such as thrombocytopenia, coagulopathy, and ascites are indicators of greater complications but are not necessarily prevented by transjugular biopsy. Percutaneous biopsy more frequently yields a diagnostic specimen than transjugular biopsy.« less

  2. Endoscopic ultrasound-guided evaluation of the pleura and cases of pleural effusion.

    PubMed

    Sharma, Malay; Rameshbabu, Chittapuram Srinivasan

    2017-01-01

    The most efficient and cost-effective approach for the diagnosis of pleural exudates remains uncertain and is a subject of controversy. Essential factors to be considered include the respective diagnostic yields of thoracocentesis, closed pleural biopsy, and thoracoscopy. The role of endoscopic ultrasound (EUS) of the esophagus as a modality for the evaluation of pleural exudates has not yet been evaluated. The applied anatomy of the pleura has been discussed. The techniques involved in the EUS imaging of different aspects of the pleura in normal cases and in cases with pleural effusion are elaborated. The practical application of this knowledge can be useful in EUS-guided sampling of the pleural wall, pleural nodules, and in cases of pleural effusion.

  3. A CT-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels

    PubMed Central

    Lin, Chia-Ying; Ou, Ming-Ching; Liu, Yi-Sheng; Chuang, Ming-Tsung; Shan, Yan-Shen; Tsai, Hong-Ming; Wang, Chien-Kuo; Tsai, Yi-Shan

    2017-01-01

    Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3%). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4%), and a successful diagnosis was made based on the biopsy outcome in 96.7% patients. Complications occurred in five patients (4.1%); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate. PMID:29205187

  4. Novel hybrid cryo‐radial method: an emerging alternative to CT‐guided biopsy in suspected lung cancer. A prospective case series and description of technique

    PubMed Central

    Yap, Elaine

    2017-01-01

    In diagnosing peripheral pulmonary lesions (PPL), radial endobronchial ultrasound (R‐EBUS) is emerging as a safer method in comparison to CT‐guided biopsy. Despite the better safety profile, the yield of R‐EBUS remains lower (73%) than CT‐guided biopsy (90%) due to the smaller size of samples. We adopted a hybrid method by adding cryobiopsy via the R‐EBUS Guide Sheath (GS) to produce larger, non‐crushed samples to improve diagnostic capability and enhance molecular testing. We report six prospective patients who underwent this procedure in our institution. R‐EBUS samples were obtained via conventional sampling methods (needle aspiration, forceps biopsy, and cytology brush), followed by a cryobiopsy. An endobronchial blocker was placed near the planned area of biopsy in advance and inflated post‐biopsy to minimize the risk of bleeding in all patients. A chest X‐ray was performed 1 h post‐procedure. All the PPLs were visualized with R‐EBUS. The mean diameter of cryobiopsy samples was twice the size of forceps biopsy samples. In four patients, cryobiopsy samples were superior in size and the number of malignant cells per high power filed and was the preferred sample selected for mutation analysis and molecular testing. There was no pneumothorax or significant bleeding to report. Cryobiopsy samples were consistently larger and were the preferred samples for molecular testing, with an increase in the diagnostic yield and reduction in the need for repeat procedures, without hindering the marked safety profile of R‐EBUS. Using an endobronchial blocker improves the safety of this procedure. PMID:29321931

  5. Novel hybrid cryo-radial method: an emerging alternative to CT-guided biopsy in suspected lung cancer. A prospective case series and description of technique.

    PubMed

    Herath, Samantha; Yap, Elaine

    2018-02-01

    In diagnosing peripheral pulmonary lesions (PPL), radial endobronchial ultrasound (R-EBUS) is emerging as a safer method in comparison to CT-guided biopsy. Despite the better safety profile, the yield of R-EBUS remains lower (73%) than CT-guided biopsy (90%) due to the smaller size of samples. We adopted a hybrid method by adding cryobiopsy via the R-EBUS Guide Sheath (GS) to produce larger, non-crushed samples to improve diagnostic capability and enhance molecular testing. We report six prospective patients who underwent this procedure in our institution. R-EBUS samples were obtained via conventional sampling methods (needle aspiration, forceps biopsy, and cytology brush), followed by a cryobiopsy. An endobronchial blocker was placed near the planned area of biopsy in advance and inflated post-biopsy to minimize the risk of bleeding in all patients. A chest X-ray was performed 1 h post-procedure. All the PPLs were visualized with R-EBUS. The mean diameter of cryobiopsy samples was twice the size of forceps biopsy samples. In four patients, cryobiopsy samples were superior in size and the number of malignant cells per high power filed and was the preferred sample selected for mutation analysis and molecular testing. There was no pneumothorax or significant bleeding to report. Cryobiopsy samples were consistently larger and were the preferred samples for molecular testing, with an increase in the diagnostic yield and reduction in the need for repeat procedures, without hindering the marked safety profile of R-EBUS. Using an endobronchial blocker improves the safety of this procedure.

  6. Ultrasound-Guided Treatment of Peripheral Nerve Pathology.

    PubMed

    Dettori, Nathan; Choudur, Hema; Chhabra, Avneesh

    2018-07-01

    High-resolution ultrasound serves as a fast, accessible, reliable, and radiation-free tool for anatomical and dynamic evaluation of various peripheral nerves. It can be used not only to identify and diagnose peripheral nerve and perineural pathology accurately but also to guide various nerve and perineural interventions. We describe the normal and pathologic appearances of peripheral nerves, the pathologies commonly affecting the individual peripheral nerves, and the current ultrasound-guided peripheral nerve interventions and techniques. Future directions are also highlighted. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara; Ferro, Carlo

    2011-02-15

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsymore » of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.« less

  8. Ultrasound-guided venous access for pacemakers and defibrillators.

    PubMed

    Seto, Arnold H; Jolly, Aaron; Salcedo, Jonathan

    2013-03-01

    Ultrasound guidance is widely recommended to reduce the risk of complications during central venous catheter placement. However, ultrasound guidance is not commonly utilized for implanting leads for cardiac rhythm management devices. We describe our technique of ultrasound-guided pacemaker implantation, including a novel pull-through technique that allows percutaneous guidewire insertion prior to the first incision. We review the literature and recent advances in ultrasound imaging technology that may facilitate the adoption of ultrasound guidance. Ultrasound guidance provides a safe and rapid technique for extrathoracic subclavian or axillary venous lead placement. © 2012 Wiley Periodicals, Inc.

  9. Forward-viewing endoscopic ultrasound-guided NOTES interventions: A study on peritoneoscopic potential

    PubMed Central

    Jeong, Seung Uk; Aizan, Hassanuddin; Song, Tae Jun; Seo, Dong Wan; Kim, Su-Hui; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan

    2013-01-01

    AIM: To evaluate the feasibility of diagnostic and therapeutic transgastric (TG) peritoneoscopic interventions with a forward-viewing endoscopic ultrasound (FV-EUS). METHODS: This prospective endoscopic experimental study used an animal model. Combined TG peritoneoscopic interventions and EUS examination of the intra-abdominal organs were performed using an FV-EUS on 10 animal models (1 porcine and 9 canine). The procedures carried out include EUS evaluation and endoscopic biopsy of intraperitoneal organs, EUS-guided fine needle aspiration (EUS-FNA), EUS-guided radiofrequency ablation (EUS-RFA), and argon plasma coagulation (APC) for hemostatic control. The animals were kept alive for 7 d, and then necropsy was performed to evaluate results and complications. RESULTS: In all 10 animals, TG peritoneoscopy, followed by endoscopic biopsy for the liver, spleen, abdominal wall, and omentum, was performed successfully. APC helped control minor bleeding. Visualization of intra-abdominal solid organs with real-time EUS was accomplished with ease. Intraperitoneal EUS-FNA was successfully performed on the liver, spleen, and kidney. Similarly, a successful outcome was achieved with EUS-RFA of the hepatic parenchyma. No adverse events were recorded during the study. CONCLUSION: Peritoneoscopic natural orifice transluminal endoscopic surgery (NOTES) interventions through FV-EUS were feasible in providing evaluation and performing endoscopic procedures. It promises potential as a platform for future EUS-based NOTES. PMID:24222961

  10. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    PubMed Central

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  11. Ultrasound-guided interventional procedures around the shoulder.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria

    2016-01-01

    Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.

  12. The effectiveness of targeted relative to empiric prophylaxis on infectious complications after transrectal ultrasound-guided prostate biopsy: a meta-analysis.

    PubMed

    Scott, Susan; Harris, Patrick N; Williamson, Deborah A; Liss, Michael A; Doi, Suhail A R; Roberts, Matthew J

    2018-07-01

    Rectal culture screening for fluoroquinolone (FQ)-resistant Enterobacteriaceae before transrectal ultrasound guided prostate (TRUSPB) biopsy and targeted antibiotic prophylaxis (TAP) may decrease post-TRUSPB infection rates compared to empiric (EAP) regimens. The objective of this study was to evaluate the effectiveness of targeted relative to empiric prophylaxis regimens on rates of infectious complications after TRUSPB and to determine the baseline prevalence of FQ resistance based on prior rectal swabs. An electronic search within literature databases including EMBASE and Web of Science (all databases) for articles assessing TAP as an approach to TRUSPB prophylaxis was conducted. Quality assessment was performed using the Hoy instrument. Meta-analysis was performed using MetaXL 5.3. From 15 studies (eight retrospective and seven prospective) representing 12,320 participants, infectious complication incidence was 3.4% in EAP and 0.8% in TAP patients. The number needed to treat with TAP to avoid one more infection when compared to the EAP group was 39. Effect sizes were homogeneous. Prevalence of FQ resistance showed low (15%) and high (28%) subgroups, likely due to region of origin (within and outside USA, respectively). Rectal culture prior to TRUSPB and use of TAP adjusts for endemic FQ resistance and is associated with less infectious complications and resulting morbidity when compared to EAP. Overtreatment associated with augmented prophylaxis approaches may be reduced as a result. Further prospective assessment and cost-benefit analyses are required before widespread implementation can be recommended.

  13. Ultrasound guided therapeutic injections of the cervical spine and brachial plexus.

    PubMed

    Cormick, Wes

    2014-02-01

    Introduction : Recent applications in ultrasound imaging include ultrasound assessment and ultrasound guided therapeutic injections of the spine and brachial plexus. Discussion : Ultrasound is an ideal modality for these regions as it allows accurate safe and quick injection of single or multiple sites. It has the added advantages of lack of ionising radiation, and can be done without requiring large expensive radiology equipment. Conclusion : Brachial plexus pathology may be present in patients presenting for shoulder symptoms where very little is found at imaging the shoulder. It is important to understand the anatomy and normal variants that may exist to be able to recognise when pathology is present. When pathology is demonstrated it is easy to do a trial of therapy with ultrasound guided injection of steroid around the nerve lesion. This review will outline the normal anatomy and variants and common pathology, which can be amenable to ultrasound guided injection of steroid.

  14. Magnetic resonance/transrectal ultrasound fusion biopsy of the prostate compared to systematic 12-core biopsy for the diagnosis and characterization of prostate cancer: multi-institutional retrospective analysis of 389 patients.

    PubMed

    Mariotti, Guilherme C; Costa, Daniel N; Pedrosa, Ivan; Falsarella, Priscila M; Martins, Tatiana; Roehrborn, Claus G; Rofsky, Neil M; Xi, Yin; M Andrade, Thais C; Queiroz, Marcos R; Lotan, Yair; Garcia, Rodrigo G; Lemos, Gustavo C; Baroni, Ronaldo H

    2016-09-01

    To determine the incremental diagnostic value of targeted biopsies added to an extended sextant biopsy scheme on a per-patient, risk-stratified basis in 2 academic centers using different multiparametric magnetic resonance imaging (MRI) protocols, a large group of radiologists, multiple biopsy systems, and different biopsy operators. All patients with suspected prostate cancer (PCa) who underwent multiparametric MRI of the prostate in 2 academic centers between February 2013 and January 2015 followed by systematic and targeted MRI-transrectal ultrasound fusion biopsy were reviewed. Risk-stratified detection rate using systematic biopsies was compared with targeted biopsies on a per-patient basis. The McNemar test was used to compare diagnostic performance of the 2 approaches. A total of 389 men met eligibility criteria. PCa was diagnosed in 47% (182/389), 52%(202/389), and 60%(235/389) of patients using the targeted, systematic, and combined (targeted plus systematic) approach, respectively. Compared with systematic biopsy, targeted biopsy diagnosed 11% (37 vs. 26) more intermediate-to-high risk (P<0.0001) and 16% (10 vs. 16) fewer low-risk tumors (P<0.0001). These results were replicated when data from each center, biopsy-naïve patients, and men with previous negative biopsies were analyzed separately. Targeted MRI-transrectal ultrasound fusion biopsy consistently improved the detection of clinically significant PCa in a large patient cohort with diverse equipment, protocols, radiologists, and biopsy operators as can be encountered in clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Endoscopic ultrasound-guided evaluation of the pleura and cases of pleural effusion

    PubMed Central

    Sharma, Malay; Rameshbabu, Chittapuram Srinivasan

    2017-01-01

    The most efficient and cost-effective approach for the diagnosis of pleural exudates remains uncertain and is a subject of controversy. Essential factors to be considered include the respective diagnostic yields of thoracocentesis, closed pleural biopsy, and thoracoscopy. The role of endoscopic ultrasound (EUS) of the esophagus as a modality for the evaluation of pleural exudates has not yet been evaluated. The applied anatomy of the pleura has been discussed. The techniques involved in the EUS imaging of different aspects of the pleura in normal cases and in cases with pleural effusion are elaborated. The practical application of this knowledge can be useful in EUS-guided sampling of the pleural wall, pleural nodules, and in cases of pleural effusion. PMID:28869229

  16. Modified perianal/pericapsular anesthesia for transrectal biopsy of prostate in patients with anal rectal problems.

    PubMed

    Kravchick, Sergey; Yoffe, Boris; Cytron, Shmuel

    2007-01-01

    To modify our technique of perianal anesthesia and use it in patients with painful conditions of the rectum and/or anus. A total of 31 consecutive patients with anal-rectal problems underwent prostate needle biopsy. Of these, 17 were referred to our hospital after vain attempts to insert a transrectal ultrasound probe. Patients received a perianal-pericapsular injection of 1% lidocaine. Pain perception was separately assessed for probe insertion and biopsies using a visual pain analog score. Only in 1 patient were we unable to insert the transrectal ultrasound probe. The mean patient age was 65.28 +/- 5.35 years. We performed a mean of 12.25 biopsies per case. At probe insertion, the mean pain score was 2.2 +/- 0.83. During the biopsy punctures, the mean pain level was 2.53 +/- 1.054. We did not find any increase in the complication rate related to the anesthesia method. Modified perianal anesthesia can be used for transrectal ultrasound-guided biopsy of the prostate in patients with anal-rectal problems, because it provides significant pain relief.

  17. Three-dimensional nonrigid landmark-based magnetic resonance to transrectal ultrasound registration for image-guided prostate biopsy.

    PubMed

    Sun, Yue; Qiu, Wu; Yuan, Jing; Romagnoli, Cesare; Fenster, Aaron

    2015-04-01

    Registration of three-dimensional (3-D) magnetic resonance (MR) to 3-D transrectal ultrasound (TRUS) prostate images is an important step in the planning and guidance of 3-D TRUS guided prostate biopsy. In order to accurately and efficiently perform the registration, a nonrigid landmark-based registration method is required to account for the different deformations of the prostate when using these two modalities. We describe a nonrigid landmark-based method for registration of 3-D TRUS to MR prostate images. The landmark-based registration method first makes use of an initial rigid registration of 3-D MR to 3-D TRUS images using six manually placed approximately corresponding landmarks in each image. Following manual initialization, the two prostate surfaces are segmented from 3-D MR and TRUS images and then nonrigidly registered using the following steps: (1) rotationally reslicing corresponding segmented prostate surfaces from both 3-D MR and TRUS images around a specified axis, (2) an approach to find point correspondences on the surfaces of the segmented surfaces, and (3) deformation of the surface of the prostate in the MR image to match the surface of the prostate in the 3-D TRUS image and the interior using a thin-plate spline algorithm. The registration accuracy was evaluated using 17 patient prostate MR and 3-D TRUS images by measuring the target registration error (TRE). Experimental results showed that the proposed method yielded an overall mean TRE of [Formula: see text] for the rigid registration and [Formula: see text] for the nonrigid registration, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm. A landmark-based nonrigid 3-D MR-TRUS registration approach is proposed, which takes into account the correspondences on the prostate surface, inside the prostate, as well as the centroid of the prostate. Experimental results indicate that the proposed method yields clinically sufficient accuracy.

  18. Guided percutaneous fine-needle aspiration biopsy of the liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, C.S.; McLoughlin, M.J.; Tao, L.C.

    1981-04-01

    Forty patients with suspected malignant disease of the liver underwent percutaneous fine-needle aspiration biopsy with radioisotope scintigraphic and fluoroscopic guidance. The needle was aimed at focal defects identified on the liver scan and several passes were made. When the scan was diffusely abnormal, the liver was widely sampled with multiple passes. Thirty patients were eventually considered to have malignant disease and aspiration biopsy was positive in 28 (93%) of these patients, including 25 of 26 with liver metastases (96%). There were two false-positive results and one minor complication. In 24 patients, conventional wide-bore needle biopsy was also performed. In thismore » group, 16 patients had a final diagnosis of hepatic malignancy. Aspiration biopsies were positive in 14 of these (87%) and conventional needle biopsies were positive in four (25%). Guided percutaneous fine-needle aspiration biopsy is recommended for pathologic diagnosis of hepatic malignancy because of its simplicity, high yield, and reasonable safety.« less

  19. Imaging-Guided Core-Needle Breast Biopsy: Impact of Meditation and Music Interventions on Patient Anxiety, Pain, and Fatigue.

    PubMed

    Soo, Mary Scott; Jarosz, Jennifer A; Wren, Anava A; Soo, Adrianne E; Mowery, Yvonne M; Johnson, Karen S; Yoon, Sora C; Kim, Connie; Hwang, E Shelley; Keefe, Francis J; Shelby, Rebecca A

    2016-05-01

    To evaluate the impact of guided meditation and music interventions on patient anxiety, pain, and fatigue during imaging-guided breast biopsy. After giving informed consent, 121 women needing percutaneous imaging-guided breast biopsy were randomized into three groups: (1) guided meditation; (2) music; (3) standard-care control group. During biopsy, the meditation and music groups listened to an audio-recorded, guided, loving-kindness meditation and relaxing music, respectively; the standard-care control group received supportive dialogue from the biopsy team. Immediately before and after biopsy, participants completed questionnaires measuring anxiety (State-Trait Anxiety Inventory Scale), biopsy pain (Brief Pain Inventory), and fatigue (modified Functional Assessment of Chronic Illness Therapy-Fatigue). After biopsy, participants completed questionnaires assessing radiologist-patient communication (modified Questionnaire on the Quality of Physician-Patient Interaction), demographics, and medical history. The meditation and music groups reported significantly greater anxiety reduction (P values < .05) and reduced fatigue after biopsy than the standard-care control group; the standard-care control group reported increased fatigue after biopsy. The meditation group additionally showed significantly lower pain during biopsy, compared with the music group (P = .03). No significant difference in patient-perceived quality of radiologist-patient communication was noted among groups. Listening to guided meditation significantly lowered biopsy pain during imaging-guided breast biopsy; meditation and music reduced patient anxiety and fatigue without compromising radiologist-patient communication. These simple, inexpensive interventions could improve women's experiences during core-needle breast biopsy. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  20. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    PubMed

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  1. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kuehl, Hilmar; Ladd, Susanne

    2007-09-15

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsiesmore » (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results.« less

  2. Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography

    PubMed Central

    Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.

    2014-01-01

    Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257

  3. Is there a role for anterior zone sampling as part of saturation trans-rectal ultrasound guided prostate biopsy?

    PubMed

    Cole, Eric; Margel, David; Greenspan, Michael; Shayegan, Bobby; Matsumoto, Edward; Fischer, Marc A; Patlas, Michael; Daya, Dean; Pinthus, Jehonathan H

    2014-05-03

    The prostatic anterior zone (AZ) is not targeted routinely by TRUS guided prostate biopsy (TRUS-Pbx). MRI is an accurate diagnostic tool for AZ tumors, but is often unavailable due to cost or system restrictions. We examined the diagnostic yield of office based AZ TRUS-Pbx. 127 men at risk for AZ tumors were studied: Patients with elevated PSA and previous extended negative TRUS-Pbx (group 1, n = 78) and actively surveyed low risk prostate cancer patients (group 2, n = 49). None of the participants had a previous AZ biopsy. Biopsy template included suspicious ultrasonic areas, 16 peripheral zone (PZ), 4 transitional zone (TZ) and 6 AZ cores. All biopsies were performed by a single urologist under local peri-prostatic anaesthetic, using the B-K Medical US System, an end-firing probe 4-12 MHZ and 18 ga/25 cm needle. All samples were reviewed by a single specialized uro-pathologist. Multivariate analysis was used to detect predictors for AZ tumors accounting for age, PSA, PSA density, prostate volume, BMI, and number of previous biopsies. Median PSA was 10.4 (group 1) and 7.3 (group 2). Age (63.9, 64.5), number of previous biopsies (1.5) and cores (17.8, 21.3) and prostate volume (56.4 cc, 51 cc) were similar for both groups. The overall diagnostic yield was 34.6% (group 1) and 85.7% (group 2). AZ cancers were detected in 21.8% (group 1) and 34.7% (group 2) but were rarely the only zone involved (1.3% and 4.1% respectively). Gleason ≥ 7 AZ cancers were often accompanied by equal grade PZ tumors. In multivariate analysis only prostate volume predicted for AZ tumors. Patients detected with AZ tumors had significantly smaller prostates (36.9 cc vs. 61.1 cc p < 0.001). Suspicious AZ ultrasonic findings were uncommon (6.3%). TRUS-Pbx AZ sampling rarely improves the diagnostic yield of extended PZ sampling in patients with elevated PSA and previous negative biopsies. In low risk prostate cancer patients who are followed by active surveillance, AZ sampling changes risk

  4. Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.

    PubMed

    Masood, Shahla; Rosa, Marilin; Kraemer, Dale F; Smotherman, Carmen; Mohammadi, Amir

    2015-08-01

    Proven as a time challenged and cost-effective sampling procedure, the use of FNAB has still remained controversial among the scientific community. Currently, other minimally invasive sampling procedures such as ultrasound guided fine needle aspiration biopsy (US-FNAB) and image guided core needle biopsy (IG-CNB) have become the preferred sampling procedures for evaluation of breast lesions. However, changes in the medical economy and the current growing emphasis on cost containment in the era of the Affordable Care Act make it necessary to stimulate a renewed interest in the use of FNAB as the initial diagnostic sampling procedure. This study was designed to define the changing trend in the practice of tissue sampling during the last several years, and to assess the comparative effectiveness and appropriateness of the procedure of choice for breast cancer diagnosis. After Institutional Review Board (IRB) approval, the computer database of the Pathology Department, University of Florida, College of Medicine-Jacksonville at UF Health was retrospectively searched to identify all breast biopsy pathology reports issued during the period of January 2004 to December 2011. The inclusion criteria were all women that underwent any of the following biopsy types: FNAB, US-FNAB, IG-CNB, and surgical biopsy (SB). Diagnostic procedures were identified using current procedural terminology (CPT) codes recorded on claims from the UF Health Jacksonville patient accounting application files. The data obtained was used to determine which technique has the best cost-effectiveness in the diagnosis of breast cancer. The outcome variable for this project was a positive breast cancer diagnosis resulting from these methodologies. The predictor variable was the biopsy type used for sampling. The rate of cancer detection for each procedure was also determined. Among the four groups of procedures compared, the lower cost was attributed to FNAB, followed by US-FNAB, and SB. IG-CNB was the most

  5. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    PubMed

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  6. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    PubMed

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P < 0.001). There was also a markedly higher quantity of cancer tissue in MRI-guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P < 0.001). With respect to the tissue quantity, superiority of MRI-guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P < 0.001) and in Gleason grade 3 + 4 = 7 cancers (59.7 ± 38.0 vs 17.7 ± 18.4 mm 2 ; P < 0.001). Comparison of biopsy Gleason grades with findings in prostatectomy specimens was possible in 80 patients with MRI-guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high

  7. Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies: An in-vitro study.

    PubMed

    Lossnitzer, Dirk; Seitz, Sebastian A; Krautz, Birgit; Schnackenburg, Bernhard; André, Florian; Korosoglou, Grigorios; Katus, Hugo A; Steen, Henning

    2015-07-26

    To investigate if magnetic resonance (MR)-guided biopsy can improve the performance and safety of such procedures. A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging (MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance (imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists. MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies.

  8. Hybrid DynaCT-guided electromagnetic navigational bronchoscopic biopsy†.

    PubMed

    Ng, Calvin S H; Yu, Simon C H; Lau, Rainbow W H; Yim, Anthony P C

    2016-01-01

    Electromagnetic navigational bronchoscopy-guided biopsy of small pulmonary nodules can be challenging. Navigational error of the system and movement of the biopsy tool during its deployment adversely affect biopsy success. Furthermore, conventional methods to confirm navigational success such as fluoroscopy and radial endobronchial ultrasound become less useful for the biopsy of small lesions. A hybrid operating theatre can provide unparalleled real-time imaging through DynaCT scan to guide and confirm successful navigation and biopsy of difficult-to-reach or small lesions. We describe our technique for DynaCT image-guided electromagnetic navigational bronchoscopic biopsy of a small pulmonary nodule in the hybrid operating theatre. The advantages, disadvantages and special considerations in adopting this approach are discussed. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Ultrasound guidance system for prostate biopsy

    NASA Astrophysics Data System (ADS)

    Hummel, Johann; Kerschner, Reinhard; Kaar, Marcus; Birkfellner, Wolfgang; Figl, Michael

    2017-03-01

    We designed a guidance system for prostate biopsy based on PET/MR images and 3D ultrasound (US). With our proposed method common inter-modal MR-US (or CT-US in case of PET/CTs) registration can be replaced by an intra-modal 3D/3D-US/US registration and an optical tracking system (OTS). On the pre-operative site, a PET/MR calibration allows to link both hybrid modalities with an abdominal 3D-US. On the interventional site, another abdominal 3D US is taken to merge the pre-operative images with the real-time 3D-US via 3D/3D-US/US registration. Finally, the images of a tracked trans-rectal US probe can be displayed with the pre-operative images by overlay. For PET/MR image fusion we applied a point-to-point registration between PET and OTS and MR and OTS, respectively. 3D/3D-US/US registration was evaluated for images taken in supine and lateral patient position. To enable table shifts between PET/MR and US image acquisition a table calibration procedure is presented. We found fiducial registration errors of 0.9 mm and 2.8 mm, respectively, with respect to the MR and PET calibration. A target registration error between MR and 3D US amounted to 1.4 mm. The registration error for the 3D/3D-US/US registration was found to be 3.7 mm. Furthermore, we have shown that ultrasound is applicable in an MR environment.

  10. Optical biopsy of the prostate: can we TRUST (trans-rectal ultrasound-coupled spectral tomography)?

    NASA Astrophysics Data System (ADS)

    Piao, Daqing; Jiang, Zhen; Bartels, Kenneth E.; Holyoak, G. Reed; Ritchey, Jerry W.; Rock, Kendra; Ownby, Charlotte L.; Bunting, Charles F.; Slobodov, Gennady

    2011-03-01

    Needle-based core-biopsy to locate prostate cancer relies heavily upon trans-rectal ultrasound (TRUS) imaging guidance. Ultrasonographic findings of classic hypoechoic peripheral zone lesions have a low specificity of ~28%, a low positive predictive value of ~29%, and an overall accuracy of ~43%, in prostate cancer diagnosis. The prevalence of isoechoic or nearly invisible prostate cancers on ultrasonography ranges from 25 to 42%. As a result, TRUS is useful and convenient to direct the needle trajectory following a systematic biopsy sampling template rather than to target only the potentially malignant lesion for focal-biopsy. To address this deficiency in the first-line of prostate cancer imaging, a trans-rectal ultrasound-coupled spectral tomography (TRUST) approach is being developed to non-invasively resolve the likely optical signatures of prostate malignancy. The approach has evolved from using one NIR wavelength to two NIR bands, and recently to three bands of NIR spectrum information. The concept has been evaluated on one normal canine prostate and three dogs with implanted prostate tumor developed as a model. The initial results implementing TRUST on the canine prostate tumor model includes: (1) quantifying substantially increased total hemoglobin concentration over the time-course of imaging in a rapidly growing prostate tumor; (2) confirming hypoxia in a prostatic cystic lesion; and (3) imaging hypoxic changes of a necrotic prostate tumor. Despite these interesting results, intensive technologic development is necessary for translating the approach to benefiting clinical practice, wherein the ultimate utility is not possibly to eliminate needle-biopsy but to perform focal-biopsy that is only necessary to confirm the cancer, as well as to monitor and predict treatment responses.

  11. Reducing infectious complications after transrectal prostate needle biopsy using a disposable needle guide: is it possible?

    PubMed

    Gurbuz, Cenk; Canat, Lutfi; Atis, Gokhan; Caskurlu, Turhan

    2011-01-01

    To investigate whether the use of a disposable needle guide results in a decreased incidence of infectious complication after transrectal prostate needle biopsy (TPNB). Fifty five patients who underwent 10-core TPNB were randomized into two groups. A pre-biopsy blood and urine examination was performed in both groups. Group 1 (25 patients) underwent biopsy with disposable biopsy needle guide and Group 2 (30 patients) underwent biopsy with reusable biopsy needle guide. All patients had a blood and negative urine culture before the procedure. The patients received ciprofloxacin 500 mg twice a day beginning the day before the biopsy and continued for 3 days after. Serum C-reactive protein levels and urine and blood specimens were obtained 48 h after the biopsy. Primary endpoint of the study was to determine the effect of needle guide on the bacteriologic urinary tract infection (UTI) rate and secondary end point was to determine symptomatic UTI. The mean age of the patients was 63.46 (range 55 to 68) years. There were no significant differences regarding the prostate-specific antigen level, prostate size, existence of comorbidity in two groups before the procedure. Bacteriologic and symptomatic UTI was detected in 4% vs. 6.6% and 4% vs. 3.9% in Group 1 and 2 relatively (P > 0.05). The use of a disposable needle guide does not appear to minimize infection risk after TPNB. Large scale and randomized studies are necessary to determine the effect of disposable needle guide on infection rate after TPNB.

  12. Major Bleeding after Percutaneous Image-Guided Biopsies: Frequency, Predictors, and Periprocedural Management

    PubMed Central

    Kennedy, Sean A.; Milovanovic, Lazar; Midia, Mehran

    2015-01-01

    Major bleeding remains an uncommon yet potentially devastating complication following percutaneous image-guided biopsy. This article reviews two cases of major bleeding after percutaneous biopsy and discusses the frequency, predictors, and periprocedural management of major postprocedural bleeding. PMID:25762845

  13. CT Guided Bone Biopsy Using a Battery Powered Intraosseous Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schnapauff, Dirk, E-mail: dirk.schnapauff@charite.de; Marnitz, Tim, E-mail: tim.marnitz@charite.de; Freyhardt, Patrick, E-mail: Patrick.freyhardt@charite.de

    2013-10-15

    Purpose: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. Methods: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. Results: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimenmore » sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 {+-} 6 to 6 {+-} 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 {+-} 87 to 111 {+-} 54 mGy Multiplication-Sign cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. Conclusion: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.« less

  14. Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.

    PubMed

    Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs

    2012-08-01

    Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.

  15. Ultrasound-guided supraclavicular block: outcome of 510 consecutive cases.

    PubMed

    Perlas, Anahi; Lobo, Giovanni; Lo, Nick; Brull, Richard; Chan, Vincent W S; Karkhanis, Reena

    2009-01-01

    Supraclavicular brachial plexus block provides consistently effective anesthesia to the upper extremity. However, traditional nerve localization techniques may be associated with a high risk of pneumothorax. In the present study, we report block success and clinical outcome data from 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery. After institutional review board approval, the outcome of 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery was reviewed. Real-time ultrasound guidance was used with a high-frequency linear probe. The neurovascular structures were imaged on short axis, and the needle was inserted using an in-plane technique with either a medial-to-lateral or lateral-to-medial orientation. Five hundred ten ultrasound-guided supraclavicular blocks were performed (50 inpatients, 460 outpatients) by 47 different operators at different levels of training over a 24-month period. Successful surgical anesthesia was achieved in 94.6% of patients after a single attempt; 2.8% required local anesthetic supplementation of a single peripheral nerve territory; and 2.6% received an unplanned general anesthetic. No cases of clinically symptomatic pneumothorax developed. Complications included symptomatic hemidiaphragmatic paresis (1%), Horner syndrome (1%), unintended vascular punctures (0.4%), and transient sensory deficits (0.4%). Ultrasound-guided supraclavicular block is associated with a high rate of successful surgical anesthesia and a low rate of complications and thus may be a safe alternative for both inpatients and outpatients. Severe underlying respiratory disease and coagulopathy should remain a contraindication for this brachial plexus approach.

  16. Diagnostic Performance of Multiparametric Magnetic Resonance Imaging and Fusion Targeted Biopsy to Detect Significant Prostate Cancer.

    PubMed

    Hoffmann, Manuela A; Taymoorian, Kasra; Ruf, Christian; Gerhards, Arnd; Leyendecker, Karlheinz; Stein, Thomas; Jakobs, Frank M; Schreckenberger, Mathias

    2017-12-01

    Multiparametric magnetic resonance imaging combined with ultrasound-fusion-targeted biopsy of the prostate intends to increase diagnostic precision, which has to be clarified. We performed multiparametric magnetic resonance imaging followed by ultrasound-fusion-guided perineal biopsy in 99 male patients with elevated prostate-specific-antigen and previous negative standard biopsy-procedures. In 33/99 patients (33%) no malignancy could be confirmed by histopathology. Low-grade carcinomas (Gleason-Score 6+7a) were found in 42/66 (64%) and high-grade carcinomas (Gleason-Score ≥7b) in 24/66 (36%) men. A high-grade carcinoma corresponded to PI-RADS 4 or 5 (suspected malignancy) in 21/24 cases, which accounted for a sensitivity of 88% and negative-predictive-value of 85% (p=0.002). Differentiation between high-/low-grade carcinomas (Gleason-Score ≤7a vs. ≥7b) by means of PI-RADS related to a sensitivity of 88% and a negative-predictive-value of 70% (p=0.74). The results support the view that multiparametric magnetic resonance imaging/ultrasound-fusion-guided biopsy promotes considerably higher detection rates of clinically relevant prostate malignancies than do conventional diagnostic procedures. With regard to differentiation between high- and low-grade carcinomas, no significant difference was demonstrated. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  17. Relationship Between Prebiopsy Multiparametric Magnetic Resonance Imaging (MRI), Biopsy Indication, and MRI-ultrasound Fusion-targeted Prostate Biopsy Outcomes.

    PubMed

    Meng, Xiaosong; Rosenkrantz, Andrew B; Mendhiratta, Neil; Fenstermaker, Michael; Huang, Richard; Wysock, James S; Bjurlin, Marc A; Marshall, Susan; Deng, Fang-Ming; Zhou, Ming; Melamed, Jonathan; Huang, William C; Lepor, Herbert; Taneja, Samir S

    2016-03-01

    Increasing evidence supports the use of magnetic resonance imaging (MRI)-ultrasound fusion-targeted prostate biopsy (MRF-TB) to improve the detection of clinically significant prostate cancer (PCa) while limiting detection of indolent disease compared to systematic 12-core biopsy (SB). To compare MRF-TB and SB results and investigate the relationship between biopsy outcomes and prebiopsy MRI. Retrospective analysis of a prospectively acquired cohort of men presenting for prostate biopsy over a 26-mo period. A total of 601 of 803 consecutively eligible men were included. All men were offered prebiopsy MRI and assigned a maximum MRI suspicion score (mSS). Men with an MRI abnormality underwent combined MRF-TB and SB. Detection rates for all PCa and high-grade PCa (Gleason score [GS] ≥7) were compared using the McNemar test. MRF-TB detected fewer GS 6 PCas (75 vs 121; p<0.001) and more GS ≥7 PCas (158 vs 117; p<0.001) than SB. Higher mSS was associated with higher detection of GS ≥7 PCa (p<0.001) but was not correlated with detection of GS 6 PCa. Prediction of GS ≥7 disease by mSS varied according to biopsy history. Compared to SB, MRF-TB identified more GS ≥7 PCas in men with no prior biopsy (88 vs 72; p=0.012), in men with a prior negative biopsy (28 vs 16; p=0.010), and in men with a prior cancer diagnosis (42 vs 29; p=0.043). MRF-TB detected fewer GS 6 PCas in men with no prior biopsy (32 vs 60; p<0.001) and men with prior cancer (30 vs 46; p=0.034). Limitations include the retrospective design and the potential for selection bias given a referral population. MRF-TB detects more high-grade PCas than SB while limiting detection of GS 6 PCa in men presenting for prostate biopsy. These findings suggest that prebiopsy multiparametric MRI and MRF-TB should be considered for all men undergoing prostate biopsy. In addition, mSS in conjunction with biopsy indications may ultimately help in identifying men at low risk of high-grade cancer for whom prostate biopsy

  18. The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl; Braak, Sicco J., E-mail: sjbraak@gmail.com

    2016-09-15

    PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented asmore » median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.« less

  19. Percutaneous transgastric computed tomography-guided biopsy of the pancreas using large needles

    PubMed Central

    Tseng, Hsiuo-Shan; Chen, Chia-Yuen; Chan, Wing P; Chiang, Jen-Huey

    2009-01-01

    AIM: To assess the safety, yield and clinical utility of percutaneous transgastric computed tomography (CT)-guided biopsy of pancreatic tumor using large needles, in selected patients. METHODS: We reviewed 34 CT-guided biopsies in patients with pancreas mass, of whom 24 (71%) had a direct path to the mass without passing through a major organ. The needle passed through the liver in one case (3%). Nine passes (26%) were made through the stomach. These nine transgastric biopsies which used a coaxial technique (i.e. a 17-gauge coaxial introducer needle and an 18-gauge biopsy needle) were the basis of this study. Immediate and late follow-up CT images to detect complications were obtained. RESULTS: Tumor tissues were obtained in nine pancreatic biopsies, and histologic specimens for diagnosis were obtained in all cases. One patient, who had a rare sarcomatoid carcinoma, received a second biopsy. One patient had a complication of transient pneumoperitoneum but no subjective complaints. An immediate imaging study and clinical follow-up detected neither hemorrhage nor peritonitis. No delayed procedure-related complication was seen during the survival period of our patients. CONCLUSION: Pancreatic biopsy can be obtained by a transgastric route using a large needle as an alternative method, without complications of peritonitis or bleeding. PMID:20014462

  20. Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

    PubMed Central

    2011-01-01

    Background: New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. Methods: We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. Results: We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). Conclusions: To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further

  1. Ultrasound image-guided therapy enhances antitumor effect of cisplatin.

    PubMed

    Sasaki, Noboru; Kudo, Nobuki; Nakamura, Kensuke; Lim, Sue Yee; Murakami, Masahiro; Kumara, W R Bandula; Tamura, Yu; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2014-01-01

    The aim of this study was to clarify whether ultrasound image-guided cisplatin delivery with an intratumor microbubble injection enhances the antitumor effect in a xenograft mouse model. Canine thyroid adenocarcinoma cells were used for all experiments. Before in vivo experiments, the cisplatin and microbubble concentration and ultrasound exposure time were optimized in vitro. For in vivo experiments, cells were implanted into the back of nude mice. Observed by a diagnostic ultrasound machine, a mixture of cisplatin and ultrasound contrast agent, Sonazoid, microbubbles was injected directly into tumors. The amount of injected cisplatin and microbubbles was 1 μg/tumor and 1.2 × 10(7) microbubbles/tumor, respectively, with a total injected volume of 20 μl. Using the same diagnostic machine, tumors were exposed to ultrasound for 15 s. The treatment was repeated four times. The combination of cisplatin, microbubbles, and ultrasound significantly delayed tumor growth as compared with no treatment (after 18 days, 157 ± 55 vs. 398 ± 49 mm(3), P = 0.049). Neither cisplatin alone nor the combination of cisplatin and ultrasound delayed tumor growth. The treatment did not decrease the body weight of mice. Ultrasound image-guided anticancer drug delivery may enhance the antitumor effects of drugs without obvious side effects.

  2. Pregnancies following ultrasound-guided drainage of tubo-ovarian abscess.

    PubMed

    Gjelland, Knut; Granberg, Seth; Kiserud, Torvid; Wentzel-Larsen, Tore; Ekerhovd, Erling

    2012-07-01

    To study fertility among women treated by means of ultrasound-guided drainage and antibiotics for tubo-ovarian abscess (TOA). Retrospective cohort study. A tertiary referral center. One hundred women of reproductive age treated for TOA between June 1986 and July 2003. Transvaginal ultrasound-guided drainage of TOA was performed in all patients. The procedure was repeated if a substantial amount of pus was seen using ultrasonography 2-5 days after the initial aspiration, and repeated later if necessary. Frequency of naturally conceived pregnancies. Twenty of 38 (52.6%; 95% CI 36.5-68.9%) women who intended to have a child achieved pregnancy naturally and became mothers. In addition, 7 (50%) of 14 women who were not on birth control on a regular basis became pregnant. No ectopic pregnancies were registered. Ultrasound-guided drainage of TOA in combination with antibiotics seems to preserve fertility in approximately half of the patients. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  3. Transurethral ultrasound-guided laser-induced prostatectomy

    NASA Astrophysics Data System (ADS)

    Babayan, Richard K.; Roth, Robert A.

    1991-07-01

    A transurethral ultrasound-guided Nd:YAG laser delivery system has been developed for use as an alternative approach to the treatment of benign prostatic hyperplasia. The TULIP system has been extensively tested in canine models and is currently undergoing FDA trials in humans.

  4. Focused ultrasound guided relocation of kidney stones.

    PubMed

    Abrol, Nitin; Kekre, Nitin S

    2015-01-01

    Complete removal of all fragments is the goal of any intervention for urinary stones. This is more important in lower pole stones where gravity and spatial orientation of lower pole infundibulum may hinder spontaneous passage of fragments. Various adjuvant therapies (inversion, diuresis, percussion, oral citrate, etc.) are described to enhance stone-free rate but are not widely accepted. Focused ultrasound-guided relocation of fragments is a recently described technique aimed at improving results of intervention for stone disease. Purpose of this review is to discuss development of this technology and its potential clinical applications. Pubmed search was made using key words "Focused ultrasound" and "kidney stone". All English language articles were reviewed by title. Relevant studies describing development and application of focused ultrasound in renal stones were selected for review. Focused ultrasound has proven its efficacy in successfully relocating up to 8 mm stone fragments in vitro and in pigs. Relocation is independent of stone composition. The latest model allows imaging and therapy with a single handheld probe facilitating its use by single operator. The acoustic energy delivered by the new prototype is even less than that used for extracorporeal shock wave lithotripsy. Therapeutic exposure has not caused thermal injury in pig kidneys. Focused ultrasound-guided relocation of stones is feasible. Though it is safe in application in pigs, technology is awaiting approval for clinical testing in human beings. This technology has many potential clinical applications in the management of stone disease.

  5. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    PubMed Central

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  6. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de; Fabel, Michael; Bolte, Hendrik

    2010-08-15

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helicallymore » bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.« less

  7. Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.

    PubMed

    Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K

    2015-02-01

    We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.

  8. Integrated sensor biopsy device for real time tissue metabolism analysis

    NASA Astrophysics Data System (ADS)

    Delgado Alonso, Jesus; Lieberman, Robert A.; DiCarmine, Paul M.; Berry, David; Guzman, Narciso; Marpu, Sreekar B.

    2018-02-01

    Current methods for guiding cancer biopsies rely almost exclusively on images derived from X-ray, ultrasound, or magnetic resonance, which essentially characterize suspected lesions based only on tissue density. This paper presents a sensor integrated biopsy device for in situ tissue analysis that will enable biopsy teams to measure local tissue chemistry in real time during biopsy procedures, adding a valuable new set of parameters to augment and extend conventional image guidance. A first demonstrator integrating three chemical and biochemical sensors was tested in a mice strain that is a spontaneous breast cancer model. In all cases, the multisensory probe was able to discriminate between healthy tissue, the edge of the tumor, and total insertion inside the cancer tissue, recording real-time information about tissue metabolism.

  9. Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters

    DTIC Science & Technology

    2015-12-01

    1 AD_________________ AWARD NUMBER: W81XWH-08-2-0162 TITLE: Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War...Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters 5a. CONTRACT NUMBER 5b. GRANT NUMBER: W81XWH-08-2-0162 5c...Purpose: To demonstrate that 1) ultrasound guided foreign body removal (USFBR) is superior to conventional surgery in the cadaver model, 2) USFBR can be

  10. Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.

    PubMed

    Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J

    2010-09-01

    Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.

  11. Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.

    PubMed

    Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A

    2010-02-01

    Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.

  12. MR-Guided Prostate Interventions

    PubMed Central

    Tempany, Clare; Straus, Sarah; Hata, Nobuhiko; Haker, Steven

    2009-01-01

    In this article the current issues of diagnosis and detection of prostate cancer are reviewed. The limitations for current techniques are highlighted and some possible solutions with MR imaging and MR-guided biopsy approaches are reviewed. There are several different biopsy approaches under investigation. These include transperineal open magnet approaches to closed-bore 1.5T transrectal biopsies. The imaging, image processing, and tracking methods are also discussed. In the arena of therapy, MR guidance has been used in conjunction with radiation methods, either brachytherapy or external delivery. The principles of the radiation treatment, the toxicities, and use of images are outlined. The future role of imaging and image-guided interventions lie with providing a noninvasive surrogate for cancer surveillance or monitoring treatment response. The shift to minimally invasive focal therapies has already begun and will be very exciting when MR-guided focused ultrasound surgery reaches its full potential. PMID:18219689

  13. Computed Tomography-Guided Biopsy for Potts Disease: An Institutional Experience from an Endemic Developing Country

    PubMed Central

    Waqas, Muhammad; Qadeer, Mohsin; Faiz, Faizuddin; Alvi, Mohammad Ali

    2015-01-01

    Study Design A retrospective chart review. Purpose In endemic resource poor countries like Pakistan, most patients are diagnosed and treated for Potts disease on clinical and radiological grounds without a routine biopsy. The purpose of this study was to evaluate the use and effect of computed tomography (CT)-guided biopsy in the management of Potts disease since the technique is becoming increasingly available. Overview of Literature CT-guided biopsy of spinal lesions is routinely performed. Literature on the utility of the technique in endemic resource poor countries is little. Methods This study was conducted at the Neurosurgery section of Aga Khan University Hospital Karachi. All the patients with suspected Potts disease who underwent CT-guided biopsy during the 7 year period from 2007 to 2013 were included in this study. Details of the procedure, histopathology and microbiology were recorded. Results One hundred and seventy-eight patients were treated for suspected Potts disease during the study period. CT-guided biopsies of the spinal lesions were performed in 91 patients (51.12%). Of the 91 procedures, 22 (24.2%) were inconclusive because of inadequate sample (10), normal tissue (6) or reactive tissue (6). Sixty-nine biopsies were positive (75.8%). Granulomatous inflammation was seen in 58 patients (84.05%), positive acid-fast bacillus (AFB) smear in 4 (5.7%) and positive AFB culture in 12 patients (17.3%). All 91 cases in which CT-guided biopsy was performed responded positively to antituberculosis therapy (ATT). Conclusions 75.8% of the specimens yielded positive diagnoses. Granulomatous inflammation on histopathology was the commonest diagnostic feature. In this series, the rates of positive AFB smear and culture were low compared to previous literature. PMID:26097654

  14. Intraoperative Magnetic Resonance Imaging-Guided Biopsy in the Diagnosis of Suprasellar Langerhans Cell Histiocytosis.

    PubMed

    Carroll, Kate T; Lochte, Bryson C; Chen, James Y; Snyder, Vivian S; Carter, Bob S; Chen, Clark C

    2018-04-01

    Magnetic resonance imaging (MRI)-guided biopsy is an emerging diagnostic technique that holds great promise for otherwise difficult to access neuroanatomy. Here we describe MRI-guided biopsy of a suprasellar lesion located posterior and superior to the pituitary stalk. The approach was implemented successfully in a 38-year-old woman who had developed progressive visual deterioration. Intraoperative MRI revealed the need for trajectory adjustment due to an unintended, minor deviation in the burr hole entry point, demonstrating the benefit of an MRI-guided approach. Langerhans cell histiocytosis was diagnosed after biopsy, and the lesion regressed after cladribine treatment. Technical nuances of the case are reviewed in the context of the available literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Target motion tracking in MRI-guided transrectal robotic prostate biopsy.

    PubMed

    Tadayyon, Hadi; Lasso, Andras; Kaushal, Aradhana; Guion, Peter; Fichtinger, Gabor

    2011-11-01

    MRI-guided prostate needle biopsy requires compensation for organ motion between target planning and needle placement. Two questions are studied and answered in this paper: 1) is rigid registration sufficient in tracking the targets with an error smaller than the clinically significant size of prostate cancer and 2) what is the effect of the number of intraoperative slices on registration accuracy and speed? we propose multislice-to-volume registration algorithms for tracking the biopsy targets within the prostate. Three orthogonal plus additional transverse intraoperative slices are acquired in the approximate center of the prostate and registered with a high-resolution target planning volume. Both rigid and deformable scenarios were implemented. Both simulated and clinical MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. average registration errors in clinical patient data were 2.6 mm for the rigid algorithm and 2.1 mm for the deformable algorithm. rigid tracking appears to be promising. Three tracking slices yield significantly high registration speed with an affordable error.

  16. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    PubMed

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  17. Usefulness of the twinkling artifact on Doppler ultrasound for the detection of breast microcalcifications.

    PubMed

    Relea, A; Alonso, J A; González, M; Zornoza, C; Bahamonde, S; Viñuela, B E; Encinas, M B

    2018-06-12

    To determine whether the twinkling artifact on Doppler ultrasound imaging corresponds to microcalcifications previously seen on mammograms and to evaluate the usefulness of this finding in the ultrasound management of suspicious microcalcifications. We used ultrasonography to prospectively examine 46 consecutive patients with groups of microcalcifications suspicious for malignancy identified at mammography, searching for the presence of the twinkling artifact to identify the microcalcifications. Once we identified the microcalcifications, we obtained core-needle biopsy specimens with 11G needles and then used X-rays to check the specimens for the presence of microcalcifications. We analyzed the percentage of detection and obtainment of microcalcifications by core-needle biopsy with this technique and the radiopathologic correlation. Microcalcifications that were not detected by ultrasound or discordant lesions were biopsied by stereotaxy at another center. We also used ultrasound guidance for preoperative marking with clips, usually orienting them radially. We identified and biopsied 41 of the 46 lesions under ultrasound guidance, including 24 of 25 carcinomas (17 in situ). B-mode ultrasound was sufficient for biopsying the microcalcifications in 14 patients, although the presence of the twinkling artifact increased the number of microcalcifications detected and thus enabled more accurate preoperative marking. Thanks to the twinkling sign, we were able to identify 27 additional groups of microcalcifications (89% vs. 30%; p < 0.05). All the surgical specimens had margins free of disease. The twinkling artifact is useful for microcalcifications in ultrasound examinations, enabling a significant increase in the yield of ultrasound-guided biopsies and better preoperative marking of groups of microcalcifications. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Multiparametric MRI followed by targeted prostate biopsy for men with suspected prostate cancer: a clinical decision analysis

    PubMed Central

    Willis, Sarah R; Ahmed, Hashim U; Moore, Caroline M; Donaldson, Ian; Emberton, Mark; Miners, Alec H; van der Meulen, Jan

    2014-01-01

    Objective To compare the diagnostic outcomes of the current approach of transrectal ultrasound (TRUS)-guided biopsy in men with suspected prostate cancer to an alternative approach using multiparametric MRI (mpMRI), followed by MRI-targeted biopsy if positive. Design Clinical decision analysis was used to synthesise data from recently emerging evidence in a format that is relevant for clinical decision making. Population A hypothetical cohort of 1000 men with suspected prostate cancer. Interventions mpMRI and, if positive, MRI-targeted biopsy compared with TRUS-guided biopsy in all men. Outcome measures We report the number of men expected to undergo a biopsy as well as the numbers of correctly identified patients with or without prostate cancer. A probabilistic sensitivity analysis was carried out using Monte Carlo simulation to explore the impact of statistical uncertainty in the diagnostic parameters. Results In 1000 men, mpMRI followed by MRI-targeted biopsy ‘clinically dominates’ TRUS-guided biopsy as it results in fewer expected biopsies (600 vs 1000), more men being correctly identified as having clinically significant cancer (320 vs 250), and fewer men being falsely identified (20 vs 50). The mpMRI-based strategy dominated TRUS-guided biopsy in 86% of the simulations in the probabilistic sensitivity analysis. Conclusions Our analysis suggests that mpMRI followed by MRI-targeted biopsy is likely to result in fewer and better biopsies than TRUS-guided biopsy. Future research in prostate cancer should focus on providing precise estimates of key diagnostic parameters. PMID:24934207

  19. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    PubMed

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  20. Photoacoustic-guided ultrasound therapy with a dual-mode ultrasound array

    NASA Astrophysics Data System (ADS)

    Prost, Amaury; Funke, Arik; Tanter, Mickaël; Aubry, Jean-François; Bossy, Emmanuel

    2012-06-01

    Photoacoustics has recently been proposed as a potential method to guide and/or monitor therapy based on high-intensity focused ultrasound (HIFU). We experimentally demonstrate the creation of a HIFU lesion at the location of an optical absorber, by use of photoacoustic signals emitted by the absorber detected on a dual mode transducer array. To do so, a dedicated ultrasound array intended to both detect photoacoustic waves and emit HIFU with the same elements was used. Such a dual-mode array provides automatically coregistered reference frames for photoacoustic detection and HIFU emission, a highly desired feature for methods involving guidance or monitoring of HIFU by use of photoacoustics. The prototype is first characterized in terms of both photoacoustic and HIFU performances. The probe is then used to perform an idealized scenario of photoacoustic-guided therapy, where photoacoustic signals generated by an absorbing thread embedded in a piece of chicken breast are used to automatically refocus a HIFU beam with a time-reversal mirror and necrose the tissue at the location of the absorber.

  1. 3D ultrasound imaging in image-guided intervention.

    PubMed

    Fenster, Aaron; Bax, Jeff; Neshat, Hamid; Cool, Derek; Kakani, Nirmal; Romagnoli, Cesare

    2014-01-01

    Ultrasound imaging is used extensively in diagnosis and image-guidance for interventions of human diseases. However, conventional 2D ultrasound suffers from limitations since it can only provide 2D images of 3-dimensional structures in the body. Thus, measurement of organ size is variable, and guidance of interventions is limited, as the physician is required to mentally reconstruct the 3-dimensional anatomy using 2D views. Over the past 20 years, a number of 3-dimensional ultrasound imaging approaches have been developed. We have developed an approach that is based on a mechanical mechanism to move any conventional ultrasound transducer while 2D images are collected rapidly and reconstructed into a 3D image. In this presentation, 3D ultrasound imaging approaches will be described for use in image-guided interventions.

  2. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less

  3. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy.

    PubMed

    Naqvi, Hanna; Edhi, Muhammad Muzzammil; Aslam, Hafiz Muhammad; Faridi, Naveen

    2013-02-12

    Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis.

  4. Ultrasound-guided central venous access using Google Glass.

    PubMed

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Addition of Ceftriaxone and Amikacin to a Ciprofloxacin plus Metronidazole Regimen for Preventing Infectious Complications of Transrectal Ultrasound-Guided Prostate Biopsy: A Randomized Controlled Trial

    PubMed Central

    Izadpanahi, Mohammad-Hossein; Majidi, Seyed Mahmood; Khorrami, Mohammad-Hatef; Mohammadi-Sichani, Mehrdad

    2017-01-01

    Background. The objective of this study was to evaluate the efficacy of adding single doses of ceftriaxone and amikacin to a ciprofloxacin plus metronidazole regimen on the reduction of infectious complications following transrectal ultrasound-guided prostate biopsy (TRUS Bx). Materials and Methods. Four hundred and fifty patients who were candidates for TRUS Bx were divided into two groups of 225 each. The control group received ciprofloxacin 500 mg orally every 12 hours together with metronidazole 500 mg orally every 8 hours from the day prior to the procedure until the fifth postoperative day. In the second group, single doses of ceftriaxone 1 g by intravenous infusion and amikacin 5 mg/kg intramuscularly were administered 30–60 minutes before TRUS Bx in addition to the oral antimicrobials described for group 1. The incidence of infection was compared between the groups. Results. The incidence of infectious complications in the intervention group was significantly lower than that in the control group (4.6% versus 0.9%, p = 0.017). Conclusion. The addition of single doses of intramuscular amikacin and intravenously infused ceftriaxone to our prophylactic regimen of ciprofloxacin plus metronidazole resulted in a statistically significant reduction of infectious complications following TRUS Bx. PMID:28167960

  6. Addition of Ceftriaxone and Amikacin to a Ciprofloxacin plus Metronidazole Regimen for Preventing Infectious Complications of Transrectal Ultrasound-Guided Prostate Biopsy: A Randomized Controlled Trial.

    PubMed

    Izadpanahi, Mohammad-Hossein; Nouri-Mahdavi, Kia; Majidi, Seyed Mahmood; Khorrami, Mohammad-Hatef; Alizadeh, Farshid; Mohammadi-Sichani, Mehrdad

    2017-01-01

    Background. The objective of this study was to evaluate the efficacy of adding single doses of ceftriaxone and amikacin to a ciprofloxacin plus metronidazole regimen on the reduction of infectious complications following transrectal ultrasound-guided prostate biopsy (TRUS Bx). Materials and Methods. Four hundred and fifty patients who were candidates for TRUS Bx were divided into two groups of 225 each. The control group received ciprofloxacin 500 mg orally every 12 hours together with metronidazole 500 mg orally every 8 hours from the day prior to the procedure until the fifth postoperative day. In the second group, single doses of ceftriaxone 1 g by intravenous infusion and amikacin 5 mg/kg intramuscularly were administered 30-60 minutes before TRUS Bx in addition to the oral antimicrobials described for group 1. The incidence of infection was compared between the groups. Results. The incidence of infectious complications in the intervention group was significantly lower than that in the control group (4.6% versus 0.9%, p = 0.017). Conclusion. The addition of single doses of intramuscular amikacin and intravenously infused ceftriaxone to our prophylactic regimen of ciprofloxacin plus metronidazole resulted in a statistically significant reduction of infectious complications following TRUS Bx.

  7. Image-guided endobronchial ultrasound

    NASA Astrophysics Data System (ADS)

    Higgins, William E.; Zang, Xiaonan; Cheirsilp, Ronnarit; Byrnes, Patrick; Kuhlengel, Trevor; Bascom, Rebecca; Toth, Jennifer

    2016-03-01

    Endobronchial ultrasound (EBUS) is now recommended as a standard procedure for in vivo verification of extraluminal diagnostic sites during cancer-staging bronchoscopy. Yet, physicians vary considerably in their skills at using EBUS effectively. Regarding existing bronchoscopy guidance systems, studies have shown their effectiveness in the lung-cancer management process. With such a system, a patient's X-ray computed tomography (CT) scan is used to plan a procedure to regions of interest (ROIs). This plan is then used during follow-on guided bronchoscopy. Recent clinical guidelines for lung cancer, however, also dictate using positron emission tomography (PET) imaging for identifying suspicious ROIs and aiding in the cancer-staging process. While researchers have attempted to use guided bronchoscopy systems in tandem with PET imaging and EBUS, no true EBUS-centric guidance system exists. We now propose a full multimodal image-based methodology for guiding EBUS. The complete methodology involves two components: 1) a procedure planning protocol that gives bronchoscope movements appropriate for live EBUS positioning; and 2) a guidance strategy and associated system graphical user interface (GUI) designed for image-guided EBUS. We present results demonstrating the operation of the system.

  8. Mediastinal abscess after endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2013-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.

  9. Use of a frameless computed tomography-guided stereotactic biopsy system for nasal biopsy in five dogs.

    PubMed

    Kuhlman, Gregory M; Taylor, Amanda R; Thieman-Mankin, Kelley M; Griffin, Jay; Cook, Audrey K; Levine, Jonathan M

    2016-04-15

    5 dogs (median age, 9 years; median body weight, 31 kg [68.2 lb]) with undefined nasal masses were examined after undergoing CT of the head and nasal biopsy via a rostral rhinoscopic or unaided (blind) approach because histologic results for collected biopsy specimens (inflammatory, necrotic, or hemorrhagic disease) suggested the specimens were nonrepresentative of the underlying disease process identified via CT (aggressive or malignant disease). Clinical signs at the time dogs were evaluated included open-mouth breathing, sneezing, or unilateral epistaxis. Histologic findings pertaining to the original biopsy specimens were suggestive of benign processes such as inflammation. In an attempt to obtain better representative specimens, a frameless CT-guided stereotactic biopsy system (CTSBS) was used to collect additional biopsy specimens from masses within the nasal and sinus passages of the dogs. The second set of biopsy specimens was histologically evaluated. Histologic evaluation of biopsy specimens collected via the CTSBS revealed results suggestive of malignant neoplasia (specifically, chondrosarcoma, hemangiopericytoma, or undifferentiated sarcoma) for 3 dogs, mild mixed-cell inflammation for 1 dog, and hamartoma for 1 dog. No complications were reported. These findings resulted in a change in treatment recommendations for 3 dogs and confirmed that no additional treatment was required for 1 dog (with hamartoma). For the remaining dog, in which CT findings and clinical history were strongly suggestive of neoplasia, the final diagnosis was rhinitis. Biopsy specimens were safely collected from masses within the nasal and sinus passages of dogs by use of a frameless CTSBS, allowing a definitive diagnosis that was unachievable with other biopsy approaches.

  10. MR-guided prostate interventions.

    PubMed

    Tempany, Clare; Straus, Sarah; Hata, Nobuhiko; Haker, Steven

    2008-02-01

    In this article the current issues of diagnosis and detection of prostate cancer are reviewed. The limitations for current techniques are highlighted and some possible solutions with MR imaging and MR-guided biopsy approaches are reviewed. There are several different biopsy approaches under investigation. These include transperineal open magnet approaches to closed-bore 1.5T transrectal biopsies. The imaging, image processing, and tracking methods are also discussed. In the arena of therapy, MR guidance has been used in conjunction with radiation methods, either brachytherapy or external delivery. The principles of the radiation treatment, the toxicities, and use of images are outlined. The future role of imaging and image-guided interventions lie with providing a noninvasive surrogate for cancer surveillance or monitoring treatment response. The shift to minimally invasive focal therapies has already begun and will be very exciting when MR-guided focused ultrasound surgery reaches its full potential. (Copyright) 2008 Wiley-Liss, Inc.

  11. Ultrasound detection of prostatic calculi as a parameter to predict the appearance of hematospermia after a prostate biopsy.

    PubMed

    Dell'Atti, Lucio

    2017-01-01

    We evaluated the correlation between prostate calculi and hematospermia in patients undergoing prostate biopsy, and its impact on sexual activity of patients. A single-center prospective randomized study of 212 patients referred for transrectal ultrasound-guided prostate biopsy (TRUSBx) was performed. All patients were divided into two groups: Group A (GA), 106 patients with moderate/marked presence of prostatic calculi visualized by TRUS; Group B (GB), 106 patients with absence/scarce of prostatic calcifications. Patients were handed questionnaires to obtain a validated data on the duration and impact of hematospermia on sexual activity. The anxiety scores were recorded using a visual analogue scale. No significant difference was noted between the two groups when comparing age, preoperative PSA level, prostate volume, and biopsy number, except for digital rectal examination (DRE) findings. Post-biopsy results of patients included in GA revealed that the complication of hematospermia was present in 65.1%, while in GB was present in 39.7% (p<0.001). On multivariate analysis for identifying significant preoperative predictors of hematospermia, which included variables of age, PSA, prostate volume, and prostate cancer were not shown to be significant predictors of hematospermia, except DRE and prostate calculi (p<0.001). The mean anxiety score was 3.7±2.8 in GA and 2.3±1.9 in GB, respectively (p<0.001). Prostatic calculi are an independent predictive factor of severe hematospermia after TRUSBx on the basis of multivariate analysis, but don't affect the positive rate of prostate cancer. Patients should be adequately counselled before TRUSBx to avoid undue anxiety and alterations in sexual activity. Copyright® by the International Brazilian Journal of Urology.

  12. Post-therapy lesions in patients with non-Hodgkin's lymphoma characterized by 18F-FDG PET/CT-guided biopsy using automated robotic biopsy arm.

    PubMed

    Radhakrishnan, Renjith K; Mittal, Bhagwant R; Basher, Rajender K; Prakash, Gaurav; Malhotra, Pankaj; Kalra, Naveen; Das, Ashim

    2018-01-01

    The aim of this study was to analyse the positive predictive value (PPV) of post-therapy fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT performed for response or recurrence evaluation in patients with non-Hodgkin's lymphoma (NHL) and to appraise the diagnostic utility of F-FDG PET/CT-guided biopsy in this setting. A total of 17 patients with NHL showing F-FDG avid lesions in F-FDG PET/CT performed for response or recurrence assessment underwent F-FDG PET/CT-guided biopsy using automated robotic biopsy arm needle navigation technique. The objectives were analysed in reference to histopathology. In all, 15 of the 17 (88.5%) procedures yielded adequate representative tissue samples. Nine out of 15 lesions were positive for residual disease and the remaining revealed benign findings on histopathology. One patient with inconclusive biopsy underwent surgical resection and histopathology confirmed the presence of residual disease. PPV of theF-FDG PET/CT was observed to be 62.5% (10/16). F-FDG PET/CT for response evaluation in NHL possesses a low PPV and hence warrants histopathological correlation when F-FDG PET/CT findings influence management decision. Diagnostic yield of F-FDG PET/CT-guided biopsy is high and has the potential to reduce sampling errors.

  13. Ultrasound-guided percutaneous injection of methylene blue to identify nerve pathology and guide surgery.

    PubMed

    Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel

    2015-09-01

    OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.

  14. Sentinel node biopsy and concomitant probe-guided tumor excision of nonpalpable breast cancer.

    PubMed

    van Rijk, Maartje C; Tanis, Pieter J; Nieweg, Omgo E; Loo, Claudette E; Olmos, Renato A Valdés; Oldenburg, Hester S A; Rutgers, Emiel J Th; Hoefnagel, Cornelis A; Kroon, Bin B R

    2007-02-01

    Preliminary data have shown encouraging results of a single intratumoral radiopharmaceutical injection that enables both sentinel node biopsy and probe-guided excision of the primary tumor in patients with nonpalpable breast cancer. The aim of the study was to evaluate this approach in a large group of patients. Lymphoscintigraphy was performed in 368 patients with nonpalpable breast cancer after intratumoral injection of (99m)Tc-nanocolloid (.2 mL, 123 MBq, 3.3 mCi) guided by ultrasound or stereotaxis. The sentinel node was pursued with the aid of vital blue dye (1.0 mL, intratumoral) and a gamma ray detection probe. In case of breast-conserving surgery, the probe was used to guide the excision. At least one sentinel node could be identified intraoperatively in 357 patients (97%), of whom 69 had involved nodes (19%). Age over 60 years was associated with less frequent nonaxillary lymphatic drainage and absence of internal mammary chain dissemination. Tumor-free margins were obtained in 262 (89%) of the 293 patients who underwent segmental excision. Re-excision of the primary tumor bed was performed in six patients (2%). During a median follow-up of 22 months, one breast recurrence and one axillary recurrence were observed. Lymphatic mapping and probe-guided tumor excision of nonpalpable breast cancer by intralesional administration of a single dose of (99m)Tc-nanocolloid and blue dye resulted in 97% identification of the sentinel node and in tumor-free margins in 89% of the patients who underwent breast-conserving surgery. Longer follow-up is needed to substantiate the accuracy and safety of this technique.

  15. Transthoracic needle biopsy of the lung

    PubMed Central

    DiBardino, David M.; Yarmus, Lonny B.

    2015-01-01

    Background Image guided transthoracic needle aspiration (TTNA) is a valuable tool used for the diagnosis of countless thoracic diseases. Computed tomography (CT) is the most common imaging modality used for guidance followed by ultrasound (US) for lesions abutting the pleural surface. Novel approaches using virtual CT guidance have recently been introduced. The objective of this review is to examine the current literature for TTNA biopsy of the lung focusing on diagnostic accuracy and safety. Methods MEDLINE was searched from inception to October 2015 for all case series examining image guided TTNA. Articles focusing on fluoroscopic guidance as well as influence of rapid on-site evaluation (ROSE) on yield were excluded. The diagnostic accuracy, defined as the number of true positives divided by the number of biopsies done, as well as the complication rate [pneumothorax (PTX), bleeding] was examined for CT guided TTNA, US guided TTNA as well as CT guided electromagnetic navigational-TTNA (E-TTNA). Of the 490 articles recovered 75 were included in our analysis. Results The overall pooled diagnostic accuracy for CT guided TTNA using 48 articles that met the inclusion and exclusion criteria was 92.1% (9,567/10,383). A similar yield was obtained examining ten articles using US guided TTNA of 88.7% (446/503). E-TTNA, being a new modality, only had one pilot study citing a diagnostic accuracy of 83% (19/23). Pooled PTX and hemorrhage rates were 20.5% and 2.8% respectively for CT guided TTNA. The PTX rate was lower in US guided TTNA at a pooled rate of 4.4%. E-TTNA showed a similar rate of PTX at 20% with no incidence of bleeding in a single pilot study available. Conclusions Image guided TTNA is a safe and accurate modality for the biopsy of lung pathology. This study found similar yield and safety profiles with the three imaging modalities examined. PMID:26807279

  16. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion PRINCIPAL...Sep 2014 - 28 Sep 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Guided Interventions for Prostate Cancer Using 3D- Transurethral Ultrasound and...Magnetic Resonance- Ultrasound (MR-US) fusion allows for specific targeting of the tumors in real-time during clinical interventions, outside of an MR

  17. Needle biopsy for hepatic vitamin A levels in lions (Panthera leo).

    PubMed

    Shamir, Merav H; Rubin, Gal; Aizenberg, Zachi; Berkovich, Zipi; Reifen, Ram; Horowitz, Igal; Bdolah-Abram, Tali; Aroch, Itamar

    2012-06-01

    Hypovitaminosis A (HA)-related skull malformations resulting in neurologic abnormalities and death have been, and still are, reported in captive lions (Panthera leo) worldwide. Liver vitamin A (VA) concentration is the most reliable indicator of animals' VA status, and its assessment is essential in prevention and treatment of HA in lions. A percutaneous needle liver biopsy using high-performance liquid chromatography ultraviolet retinoid analysis for VA concentration measurement was validated. It was first assessed in vitro using chicken liver. Later, the safety and feasibility of ultrasound-guided percutaneous needle liver biopsy was assessed in living lions. Hepatic VA concentrations in lion liver were measured using the above laboratory method. Mean chicken hepatic VA concentration in needle biopsy (NB) and wedge biopsy (WB) of the same liver lobes were 108.66 and 60.89 microg/g wet tissue, respectively, and were significantly (P = 0.03) correlated (r = 0.74). The calculated linear regression for predicting VA concentration in WB using NB VA for chicken liver was 25.194 + 0.3234x NB (microg/g). Four ultrasound-guided percutaneous needle liver biopsies were obtained from each of the four lions under general anesthesia. Mean hepatic VA concentration was 8.25 microg/g wet tissue (range 1.43-25.29 microg/g). Mean serum VA concentration, measured in these four lions was 1,011.1 nmol/L with a standard deviation of 337.91 nmol/L (range 590.26-1,077.2 nmol/L). The lions recovered uneventfully, and no complications were observed during a 4-yr follow-up period. In conclusion, the percutaneous needle liver biopsy technique is a reliable, practical, safe tool for obtaining liver tissue samples antemortem for assessment of the VA status in lions and can be used in future studies.

  18. Spectrum of intra-thoracic lesion detected by computed tomography guided fine needle aspiration biopsy

    PubMed Central

    2013-01-01

    Background Fine needle aspiration biopsy (FNAB) is a rapid, sensitive and inexpensive procedure for diagnosing benign and malignant palpable lesions. For lesions that are not palpable or deep seated, FNAB can be performed under the guidance of radiological imaging. Our basic objective was to evaluate the spectrum of intrathoracic lesions by using Computed Tomography guided fine needle aspiration biopsy and evaluate its diagnostic yield. Methodology It was a retrospective study carried out in the Department of Histopathology, Liaquat National Hospital and Medical College, during the months of August 2011 and August 2012. All patients with pulmonary, mediastinal or paravertebral mass who underwent CT guided intrathoracic biopsy were included in this study. Fine needle aspiration biopsies were performed in the Radiology Department and specimen retrieved was sent in 10% buffered Formalin to the Histopathology Department. All the data was entered and analyzed through SPSS 19.0. Results A total of 130 cases were evaluated, out of which 108 (83.1%) were pulmonary, 16 (12.3%) were mediastinal and 6 (4.6%) were paravertebral. Conclusive biopsies were possible in 113 cases, while 17 biopsies were inconclusive. In those that showed a conclusive diagnosis, 83.1% were neoplastic and 16.9% were non neoplastic. Of the neoplastic cases, 27 (20.8%) were adenocarcinomas, followed by squamous cell carcinomas (15.4%) and large cell carcinoma, not otherwise specified, (12.3%). Conclusion CT guided fine needle aspiration biopsy is a reliable tool for examination of intrathoracic lesions, with a high rate of conclusive diagnosis. PMID:23402220

  19. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    PubMed

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  20. Treatment efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation for benign thyroid nodules

    PubMed Central

    Li, Xiao-long; Lu, Feng; Yue, Wen-wen; Sun, Li-ping; Bo, Xiao-wan; Guo, Le-hang; Xu, Jun-mei; Liu, Bo-ji; Li, Dan-dan; Qu, Shen

    2016-01-01

    Objective: To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. Methods: The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150–T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. Results: In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47–16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510–17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. Conclusion: Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. Advances in knowledge: Based on the comparable efficacy and clinical

  1. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  2. Ultrasound of the thyroid and parathyroid glands.

    PubMed

    Barraclough, B M; Barraclough, B H

    2000-02-01

    The superficial position of thyroid and parathyroid glands facilitates the use of diagnostic ultrasound (US) as an imaging technique. Techniques of image acquisition and interpretation are described in detail. Size and morphology of glands can be defined easily. The most important use of US guided biopsy in relation to thyroid and parathyroid glands is to increase diagnostic accuracy.

  3. Twelve-month prostate volume reduction after MRI-guided transurethral ultrasound ablation of the prostate.

    PubMed

    Bonekamp, David; Wolf, M B; Roethke, M C; Pahernik, S; Hadaschik, B A; Hatiboglu, G; Kuru, T H; Popeneciu, I V; Chin, J L; Billia, M; Relle, J; Hafron, J; Nandalur, K R; Staruch, R M; Burtnyk, M; Hohenfellner, M; Schlemmer, H-P

    2018-06-25

    To quantitatively assess 12-month prostate volume (PV) reduction based on T2-weighted MRI and immediate post-treatment contrast-enhanced MRI non-perfused volume (NPV), and to compare measurements with predictions of acute and delayed ablation volumes based on MR-thermometry (MR-t), in a central radiology review of the Phase I clinical trial of MRI-guided transurethral ultrasound ablation (TULSA) in patients with localized prostate cancer. Treatment day MRI and 12-month follow-up MRI and biopsy were available for central radiology review in 29 of 30 patients from the published institutional review board-approved, prospective, multi-centre, single-arm Phase I clinical trial of TULSA. Viable PV at 12 months was measured as the remaining PV on T2-weighted MRI, less 12-month NPV, scaled by the fraction of fibrosis in 12-month biopsy cores. Reduction of viable PV was compared to predictions based on the fraction of the prostate covered by the MR-t derived acute thermal ablation volume (ATAV, 55°C isotherm), delayed thermal ablation volume (DTAV, 240 cumulative equivalent minutes at 43°C thermal dose isocontour) and treatment-day NPV. We also report linear and volumetric comparisons between metrics. After TULSA, the median 12-month reduction in viable PV was 88%. DTAV predicted a reduction of 90%. Treatment day NPV predicted only 53% volume reduction, and underestimated ATAV and DTAV by 36% and 51%. Quantitative volumetry of the TULSA phase I MR and biopsy data identifies DTAV (240 CEM43 thermal dose boundary) as a useful predictor of viable prostate tissue reduction at 12 months. Immediate post-treatment NPV underestimates tissue ablation. • MRI-guided transurethral ultrasound ablation (TULSA) achieved an 88% reduction of viable prostate tissue volume at 12 months, in excellent agreement with expectation from thermal dose calculations. • Non-perfused volume on immediate post-treatment contrast-enhanced MRI represents only 64% of the acute thermal ablation volume

  4. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Using 19-G Needle for Sarcoidosis.

    PubMed

    Balwan, Akshu

    2018-05-16

    Flexible bronchoscopy with endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is increasingly being used to obtain pathology specimens for diagnosis of sarcoidosis. There is wide variation in reported diagnostic yield in literature. New TBNA needles are available in the market but data are lacking about their diagnostic yield especially for sarcoidosis. This study reports the diagnostic yield of bronchoscopy with EBUS-TBNA using ViziShot FLEX 19-G needle in a series of patients with suspected sarcoidosis. This is a retrospective chart review for diagnostic yield of the 19-G EBUS-TBNA needle for suspected sarcoidosis. Eighty-six EBUS bronchoscopies were performed, 15 were done with clinical suspicion of sarcoidosis. The 19-G needle was used for all cases of suspected sarcoidosis. The procedure was diagnostic of sarcoidosis in 14 (93.3%) patients by TBNA with 1 nondiagnostic bronchoscopy. Procedural diagnostic yield was 93.3%. Eighty-five percent (28/33) of sampled lymph nodes were positive for noncaseating granulomas. The yield of transbronchial lung biopsy (TBLB) and endobronchial lung biopsy was 38% (5/13) and 43% (6/14), respectively. TBLB and endobronchial lung biopsy did not add to the diagnostic yield of the procedure. No significant adverse events were noted. This series reports a higher diagnostic yield than most other published studies and opens platform for direct comparison of each available needle. It also adds to the safety data for this larger needle. In addition, it raises doubt into utility of TBLB for diagnosis of sarcoidosis, which can increase the procedural complications.

  5. MR guided breast interventions: role in biopsy targeting and lumpectomies

    PubMed Central

    Jagadeesan, Jayender; Richman, Danielle M; Kacher, Daniel F

    2015-01-01

    Synopsis Contrast enhanced breast MRI is increasingly being used to diagnose breast cancer and to perform biopsy procedures. The American Cancer Society has advised women at high risk for breast cancer to have breast MRI screening as an adjunct to screening mammography. This article places special emphasis on biopsy and operative planning involving MRI and reviews utility of breast MRI in monitoring response to neoadjuvant chemotherapy. We describe peer-reviewed data on currently accepted MR-guided therapeutic methods for addressing benign and malignant breast diseases, including intraoperative imaging. PMID:26499274

  6. Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.

    PubMed

    Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N

    2015-01-01

    The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.

  7. Papilloma diagnosed at MRI-guided vacuum-assisted breast biopsy: is surgical excision still warranted?

    PubMed

    Brennan, Sandra B; Corben, Adriana; Liberman, Laura; Dershaw, D David; Brogi, Edi; Van Zee, Kimberly J; Morris, Elizabeth

    2012-10-01

    The objective of our study was to determine the frequency of cancer at surgery in breast lesions yielding papilloma at MRI-guided 9-gauge vacuum-assisted biopsy (VAB) and to determine whether any features are associated with cancer upgrade. For this study, 1487 MRI-guided vacuum-assisted biopsies performed from January 2004 to March 2011 were reviewed. Lesions yielding papilloma were identified and classified as papilloma with or without atypia. Surgical findings were reviewed to determine the cancer rate. Statistical analysis was performed and 95% CIs were calculated. Papilloma was identified in 75 of the 1487 MRI-guided vacuum-assisted biopsies (5%). These 75 papillomas occurred in 73 women with a median age of 49 years (age range, 27-70 years). Of the 75 papillomas, 25 (33%) had atypia and 50 (67%) did not on core needle biopsy. Subsequent surgery of 67 of the 75 papillomas (89%) yielded ductal carcinoma in situ (DCIS) in four (6%; 95% CI, 2-15%). Surgery yielded DCIS in two of 23 papillomas with atypia (9%; 95% CI, 1-28%) at MRI-guided VAB and in two of 44 papillomas without atypia (5%; 95% CI, 0.4-16%) at MRI-guided VAB; these cancer rates did not differ significantly (p=0.6). Postmenopausal status (p=0.04) and histologic size of less than 0.2 cm (p=0.04) had a significant association with the cancer upgrade rate. Papilloma with or without atypia was found in 5% of patients who underwent MRI-guided VAB during the study period. Surgery revealed cancer in 6%. DCIS was found at surgery in 9% of lesions yielding papilloma with atypia versus 5% of lesions yielding papilloma without atypia. For lesions yielding papilloma with or without atypia at MRI-guided VAB, surgical excision is warranted.

  8. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    PubMed

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  9. Bone Biopsy

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Bone Biopsy Bone biopsy uses a needle and imaging ... the limitations of Bone Biopsy? What is a Bone Biopsy? A bone biopsy is an image-guided ...

  10. CT fluoroscopy guided transpleural cutting needle biopsy of small (≤2.5 cm) subpleural pulmonary nodules.

    PubMed

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut; Mostbeck, Gerhard H

    2011-01-01

    Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  11. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    PubMed

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  13. Impact of Lesion Visibility on Transrectal Ultrasound on the Prediction of Clinically Significant Prostate Cancer (Gleason Score 3 + 4 or Greater) with Transrectal Ultrasound-Magnetic Resonance Imaging Fusion Biopsy.

    PubMed

    Garcia-Reyes, Kirema; Nguyen, Hao G; Zagoria, Ronald J; Shinohara, Katsuto; Carroll, Peter R; Behr, Spencer C; Westphalen, Antonio C

    2017-09-20

    The purpose of this study was to estimate the impact of lesion visibility with transrectal ultrasound on the prediction of clinically significant prostate cancer with transrectal ultrasound-magnetic resonance imaging fusion biopsy. This HIPAA (Health Insurance Portability and Accountability Act) compliant, institutional review board approved, retrospective study was performed in 178 men who were 64.7 years old with prostate specific antigen 8.9 ng/ml. They underwent transrectal ultrasound-magnetic resonance imaging fusion biopsy from January 2013 to September 2016. Visible lesions on magnetic resonance imaging were assigned a PI-RADS™ (Prostate Imaging Reporting and Data System), version 2 score of 3 or greater. Transrectal ultrasound was positive when a hypoechoic lesion was identified. We used a 3-level, mixed effects logistic regression model to determine how transrectal ultrasound-magnetic resonance imaging concordance predicted the presence of clinically significant prostate cancer. The diagnostic performance of the 2 methods was estimated using ROC curves. A total of 1,331 sextants were targeted by transrectal ultrasound-magnetic resonance imaging fusion or systematic biopsies, of which 1,037 were negative, 183 were Gleason score 3 + 3 and 111 were Gleason score 3 + 4 or greater. Clinically significant prostate cancer was diagnosed by transrectal ultrasound and magnetic resonance imaging alone at 20.5% and 19.7% of these locations, respectively. Men with positive imaging had higher odds of clinically significant prostate cancer than men without visible lesions regardless of modality (transrectal ultrasound OR 14.75, 95% CI 5.22-41.69, magnetic resonance imaging OR 12.27, 95% CI 6.39-23.58 and the 2 modalities OR 28.68, 95% CI 14.45-56.89, all p <0.001). The ROC AUC to detect clinically significant prostate cancer using the 2 methods (0.85, 95% CI 0.81-0.89) was statistically greater than that of transrectal ultrasound alone (0.80, 95% CI 0.76-0.85, p = 0

  14. Electromagnetic navigation system for CT-guided biopsy of small lesions.

    PubMed

    Appelbaum, Liat; Sosna, Jacob; Nissenbaum, Yizhak; Benshtein, Alexander; Goldberg, S Nahum

    2011-05-01

    The purpose of this study was to evaluate an electromagnetic navigation system for CT-guided biopsy of small lesions. Standardized CT anthropomorphic phantoms were biopsied by two attending radiologists. CT scans of the phantom and surface electromagnetic fiducial markers were imported into the memory of the 3D electromagnetic navigation system. Each radiologist assessed the accuracy of biopsy using electromagnetic navigation alone by targeting sets of nine lesions (size range, 8-14 mm; skin to target distance, 5.7-12.8 cm) under eight different conditions of detector field strength and orientation (n = 117). As a control, each radiologist also biopsied two sets of five targets using conventional CT-guided technique. Biopsy accuracy, number of needle passes, procedure time, and radiation dose were compared. Under optimal conditions (phantom perpendicular to the electromagnetic receiver at highest possible field strength), phantom accuracy to the center of the lesion was 2.6 ± 1.1 mm. This translated into hitting 84.4% (38/45) of targets in a single pass (1.1 ± 0.4 CT confirmations), which was significantly fewer than the 3.6 ± 1.3 CT checks required for conventional technique (p < 0.001). The mean targeting time was 38.8 ± 18.2 seconds per lesion. Including procedural planning (∼5.5 minutes) and final CT confirmation of placement (∼3.5 minutes), the full electromagnetic tracking procedure required significantly less time (551.6 ± 87.4 seconds [∼9 minutes]) than conventional CT (833.3 ± 283.8 seconds [∼14 minutes]) for successful targeting (p < 0.001). Less favorable conditions, including nonperpendicular relation between the axis of the machine and weaker field strength, resulted in statistically significant lower accuracy (3.7 ± 1 mm, p < 0.001). Nevertheless, first-pass biopsy accuracy was 58.3% (21/36) and second-pass (35/36) accuracy was 97.2%. Lesions farther from the skin than 20-25 cm were out of range for successful electromagnetic tracking

  15. Esophageal-guided biopsy with volumetric laser endomicroscopy and laser cautery marking: a pilot clinical study.

    PubMed

    Suter, Melissa J; Gora, Michalina J; Lauwers, Gregory Y; Arnason, Thomas; Sauk, Jenny; Gallagher, Kevin A; Kava, Lauren; Tan, Khay M; Soomro, Amna R; Gallagher, Timothy P; Gardecki, Joseph A; Bouma, Brett E; Rosenberg, Mireille; Nishioka, Norman S; Tearney, Guillermo J

    2014-06-01

    Biopsy surveillance protocols for the assessment of Barrett's esophagus can be subject to sampling errors, resulting in diagnostic uncertainty. Optical coherence tomography is a cross-sectional imaging technique that can be used to conduct volumetric laser endomicroscopy (VLE) of the entire distal esophagus. We have developed a biopsy guidance platform that places endoscopically visible marks at VLE-determined biopsy sites. The objective of this study was to demonstrate in human participants the safety and feasibility of VLE-guided biopsy in vivo. A pilot feasibility study. Massachusetts General Hospital. A total of 22 participants were enrolled from January 2011 to June 2012 with a prior diagnosis of Barrett's esophagus. Twelve participants were used to optimize the laser marking parameters and the system platform. A total of 30 target sites were selected and marked in real-time by using the VLE-guided biopsy platform in the remaining 10 participants. Volumetric laser endomicroscopy. Endoscopic and VLE visibility, and accuracy of VLE diagnosis of the tissue between the laser cautery marks. There were no adverse events of VLE and laser marking. The optimal laser marking parameters were determined to be 2 seconds at 410 mW, with a mark separation of 6 mm. All marks made with these parameters were visible on endoscopy and VLE. The accuracies for diagnosing tissue in between the laser cautery marks by independent blinded readers for endoscopy were 67% (95% confidence interval [CI], 47%-83%), for VLE intent-to-biopsy images 93% (95% CI, 78%-99%), and for corrected VLE post-marking images 100% when compared with histopathology interpretations. This is a single-center feasibility study with a limited number of patients. Our results demonstrate that VLE-guided biopsy of the esophagus is safe and can be used to guide biopsy site selection based on the acquired volumetric optical coherence tomography imaging data. ( NCT01439633.). Copyright © 2014 American Society for

  16. Esophageal-guided biopsy with volumetric laser endomicroscopy and laser cautery marking: a pilot clinical study

    PubMed Central

    Suter, Melissa J.; Gora, Michalina J.; Lauwers, Gregory Y.; Arnason, Thomas; Sauk, Jenny; Gallagher, Kevin A.; Kava, Lauren; Tan, Khay M.; Soomro, Amna R.; Gallagher, Timothy P.; Gardecki, Joseph A.; Bouma, Brett E.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2018-01-01

    Background Biopsy surveillance protocols for the assessment of Barrett’s esophagus can be subject to sampling errors, resulting in diagnostic uncertainty. Optical coherence tomography is a cross-sectional imaging technique that can be used to conduct volumetric laser endomicroscopy (VLE) of the entire distal esophagus. We have developed a biopsy guidance platform that places endoscopically visible marks at VLE-determined biopsy sites. Objective The objective of this study was to demonstrate in human participants the safety and feasibility of VLE-guided biopsy in vivo. Design A pilot feasibility study. Setting Massachusetts General Hospital. Patients A total of 22 participants were enrolled from January 2011 to June 2012 with a prior diagnosis of Barrett’s esophagus. Twelve participants were used to optimize the laser marking parameters and the system platform. A total of 30 target sites were selected and marked in real-time by using the VLE-guided biopsy platform in the remaining 10 participants. Intervention Volumetric laser endomicroscopy. Main Outcome Measurements Endoscopic and VLE visibility, and accuracy of VLE diagnosis of the tissue between the laser cautery marks. Results There were no adverse events of VLE and laser marking. The optimal laser marking parameters were determined to be 2 seconds at 410 mW, with a mark separation of 6 mm. All marks made with these parameters were visible on endoscopy and VLE. The accuracies for diagnosing tissue in between the laser cautery marks by independent blinded readers for endoscopy were 67% (95% confidence interval [CI], 47%–83%), for VLE intent-to-biopsy images 93% (95% CI, 78%–99%), and for corrected VLE post-marking images 100% when compared with histopathology interpretations. Limitations This is a single-center feasibility study with a limited number of patients. Conclusion Our results demonstrate that VLE-guided biopsy of the esophagus is safe and can be used to guide biopsy site selection based on the

  17. Endobronchial ultrasound-guided lymph node biopsy with transbronchial needle forceps: a pilot study.

    PubMed

    Herth, F J F; Schuler, H; Gompelmann, D; Kahn, N; Gasparini, S; Ernst, A; Schuhmann, M; Eberhardt, R

    2012-02-01

    One limitation of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the size of the available needles, frequently yielding only cells for cytological examination. The aim of this pilot study was to evaluate the efficacy and safety of newly developed needle forceps to obtain tissue for the histological diagnosis of enlarged mediastinal lymph nodes. Patients with enlarged, positron emission tomography (PET)-positive lymph nodes were included. The transbronchial needle forceps (TBNF), a sampling instrument combining the characteristics of a needle (bevelled tip for penetrating through the bronchial wall) with forceps (two serrated jaws for grasping tissue) was used through the working channel of the EBUS-TBNA scope. Efficacy and safety was assessed. 50 patients (36 males and 14 females; mean age 51 yrs) with enlarged or PET-positive lymph nodes were included in this pilot study. In 48 (96%) patients penetration of the bronchial wall was possible and in 45 patients tissue for histological diagnosis was obtained. In three patients TBNF provided inadequate material. For patients in whom the material was adequate for a histological examination, a specific diagnosis was established in 43 (86%) out of 50 patients (nonsmall cell lung cancer: n=24; small cell lung cancer: n=7; sarcoidosis: n=4; Hodgkin's lymphoma: n=4; tuberculosis: n=2; and non-Hodgkin's lymphoma: n=2).No clinically significant procedure-related complications were encountered. This study demonstrated that EBUS-TBNF is a safe procedure and provides diagnostic histological specimens of mediastinal lymph nodes.

  18. A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.

    PubMed

    Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I

    2017-09-01

    To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?

    PubMed Central

    Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas

    2017-01-01

    OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776

  20. BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    PubMed

    Chen, Dong; Chen, Weisheng; Huang, Lipeng; Feng, Xuegang; Peters, Terry; Gu, Lixu

    2017-09-01

    Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance. This approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance. We evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively. The experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

  1. Endoscopic Ultrasound Elastography: Current Clinical Use in Pancreas.

    PubMed

    Mondal, Utpal; Henkes, Nichole; Patel, Sandeep; Rosenkranz, Laura

    2016-08-01

    Elastography is a newer technique for the assessment of tissue elasticity using ultrasound. Cancerous tissue is known to be stiffer (hence, less elastic) than corresponding healthy tissue, and as a result, could be identified in an elasticity-based imaging. Ultrasound elastography has been used in the breast, thyroid, and cervix to differentiate malignant from benign neoplasms and to guide or avoid unnecessary biopsies. In the liver, elastography has enabled a noninvasive and reliable estimate of fibrosis. Endoscopic ultrasound has become a robust diagnostic and therapeutic tool for the management of pancreatic diseases. The addition of elastography to endoscopic ultrasound enabled further characterization of pancreas lesions, and several European and Asian studies have reported encouraging results. The current clinical role of endoscopic ultrasound elastography in the management of pancreas disorders and related literature are reviewed.

  2. Multimodal US-gamma imaging using collaborative robotics for cancer staging biopsies.

    PubMed

    Esposito, Marco; Busam, Benjamin; Hennersperger, Christoph; Rackerseder, Julia; Navab, Nassir; Frisch, Benjamin

    2016-09-01

    The staging of female breast cancer requires detailed information about the level of cancer spread through the lymphatic system. Common practice to obtain this information for patients with early-stage cancer is sentinel lymph node (SLN) biopsy, where LNs are radioactively identified for surgical removal and subsequent histological analysis. Punch needle biopsy is a less invasive approach but suffers from the lack of combined anatomical and nuclear information. We present and evaluate a system that introduces live collaborative robotic 2D gamma imaging in addition to live 2D ultrasound to identify SLNs in the surrounding anatomy. The system consists of a robotic arm equipped with both a gamma camera and a stereoscopic tracking system that monitors the position of an ultrasound probe operated by the physician. The arm cooperatively places the gamma camera parallel to the ultrasound imaging plane to provide live multimodal visualization and guidance. We validate the system by evaluating the target registration errors between fused nuclear and US image data in a phantom consisting of two spheres, one of which is filled with radioactivity. Medical experts perform punch biopsies on agar-gelatine phantoms with complex configurations of hot and cold lesions to provide a qualitative and quantitative evaluation of the system. The average point registration error for the overlay is [Formula: see text] mm. The time of the entire procedure was reduced by 36 %, with 80v of the biopsies being successful. The users' feedback was very positive, and the system was deemed to be very intuitive, with handling similar to classic US-guided needle biopsy. We present and evaluate the first medical collaborative robotic imaging system. Feedback from potential users for SLN punch needle biopsy is encouraging. Ongoing work investigates the clinical feasibility with more complex and realistic phantoms.

  3. Manually controlled targeted prostate biopsy with real-time fusion imaging of multiparametric magnetic resonance imaging and transrectal ultrasound: an early experience.

    PubMed

    Shoji, Sunao; Hiraiwa, Shinichiro; Endo, Jun; Hashida, Kazunobu; Tomonaga, Tetsuro; Nakano, Mayura; Sugiyama, Tomoko; Tajiri, Takuma; Terachi, Toshiro; Uchida, Toyoaki

    2015-02-01

    To report our early experience with manually controlled targeted biopsy with real-time multiparametric magnetic resonance imaging and transrectal ultrasound fusion images for the diagnosis of prostate cancer. A total of 20 consecutive patients suspicious of prostate cancer at the multiparametric magnetic resonance imaging scan were recruited prospectively. Targeted biopsies were carried out for each cancer-suspicious lesion, and 12 systematic biopsies using the BioJet system. Pathological findings of targeted and systematic biopsies were analyzed. The median age of the patients was 70 years (range 52-83 years). The median preoperative prostate-specific antigen value was 7.4 ng/mL (range 3.54-19.9 ng/mL). Median preoperative prostate volume was 38 mL (range 24-68 mL). The number of cancer-detected cases was 14 (70%). The median Gleason score was 6.5 (range 6-8). Cancer-detected rates of the systematic and targeted biopsy cores were 6.7 and 31.8%, respectively (P < 0.0001). In six patients who underwent radical prostatectomy, the geographic locations and pathological grades of clinically significant cancers and index lesions corresponded to the pathological results of the targeted biopsies. Prostate cancers detected by targeted biopsies with manually controlled targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound fusion imaging have significantly higher grades and longer length compared with those detected by systematic biopsies. Further studies and comparison with the pathological findings of whole-gland specimens have the potential to determine the role of this biopsy methodology in patients selected for focal therapy and those under active surveillance. © 2014 The Japanese Urological Association.

  4. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    PubMed Central

    Allam, Abdallah El-Sayed; Khalil, Adham Aboul Fotouh; Eltawab, Basma Aly; Wu, Wei-Ting

    2018-01-01

    Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves. PMID:29808105

  5. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. Robotically assisted small animal MRI-guided mouse biopsy

    NASA Astrophysics Data System (ADS)

    Wilson, Emmanuel; Chiodo, Chris; Wong, Kenneth H.; Fricke, Stanley; Jung, Mira; Cleary, Kevin

    2010-02-01

    Small mammals, namely mice and rats, play an important role in biomedical research. Imaging, in conjunction with accurate therapeutic agent delivery, has tremendous value in small animal research since it enables serial, non-destructive testing of animals and facilitates the study of biomarkers of disease progression. The small size of organs in mice lends some difficulty to accurate biopsies and therapeutic agent delivery. Image guidance with the use of robotic devices should enable more accurate and repeatable targeting for biopsies and delivery of therapeutic agents, as well as the ability to acquire tissue from a pre-specified location based on image anatomy. This paper presents our work in integrating a robotic needle guide device, specialized stereotaxic mouse holder, and magnetic resonance imaging, with a long-term goal of performing accurate and repeatable targeting in anesthetized mice studies.

  7. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  8. MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics

    PubMed Central

    Napoli, Alessandro; Sacconi, Beatrice; Battista, Giuseppe; Guglielmi, Giuseppe; Catalano, Carlo; Albisinni, Ugo

    2016-01-01

    MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a “new” interventional technique and on its applications for MSK and allied sciences. PMID:26607640

  9. Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fritz, Jan, E-mail: jfritz9@jhmi.edu; Tzaribachev, Nikolay; Thomas, Christoph

    2012-02-15

    Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree;more » Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.« less

  10. Incidence of major hemorrhage after aggressive image-guided liver mass biopsy in the era of individualized medicine.

    PubMed

    Boyum, James H; Atwell, Thomas D; Wall, Darci J; Mansfield, Aaron S; Kerr, Sarah E; Gunderson, Tina M; Rumilla, Kandelaria M; Weisbrod, Adam J; Kurup, A Nicholas

    2018-05-17

    To analyze a large volume of image-guided liver mass biopsies to assess for an increased incidence of major hemorrhage after aggressive liver mass sampling, and to determine if coaxial technique reduces major hemorrhage rate. Patients who underwent image-guided liver mass biopsy over a 15-year period (December 7, 2001-September 22, 2016) were retrospectively identified. An aggressive biopsy was defined as a biopsy event in which ≥ 4 core needle passes were performed. Association of major hemorrhage after aggressive liver mass biopsy and other potential risk factors of interest were assessed using logistic regression analysis. For the subset of aggressive biopsies, Fisher's exact test was used to compare the incidence of major hemorrhage using coaxial versus noncoaxial techniques. Aggressive biopsies constituted 11.6% of biopsy events (N =579/5011). The incidence of major hemorrhage with <4 passes was 0.4% (N =18/4432) and with ≥4 passes 1.2% (N =6/579). In univariable models, aggressive biopsy was significantly associated with major hemorrhage (OR 3.0, 95% CI 1.16-6.92, p =0.025). After adjusting for gender and platelet count, the association was not significant at the p =0.05 level (OR 2.58, 95% CI 0.927-6.24, p =0.067). The rate of major hemorrhage in the coaxial biopsy technique group was 1.4% (N =3/209) compared to 1.1% (N =4/370) in the noncoaxial biopsy technique group, which was not a significant difference (p =0.707). Although aggressive image-guided liver mass biopsies had an increased incidence of major hemorrhage, the overall risk of bleeding remained low. The benefit of such biopsies will almost certainly outweigh the risk in most patients.

  11. High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy

    PubMed Central

    Copelan, Alexander; Hartman, Jason; Chehab, Monzer; Venkatesan, Aradhana M.

    2015-01-01

    Image-guided high-intensity focused ultrasound (HIFU) is an innovative therapeutic technology, permitting extracorporeal or endocavitary delivery of targeted thermal ablation while minimizing injury to the surrounding structures. While ultrasound-guided HIFU was the original image-guided system, MR-guided HIFU has many inherent advantages, including superior depiction of anatomic detail and superb real-time thermometry during thermoablation sessions, and it has recently demonstrated promising results in the treatment of both benign and malignant tumors. HIFU has been employed in the management of prostate cancer, hepatocellular carcinoma, uterine leiomyomas, and breast tumors, and has been associated with success in limited studies for palliative pain management in pancreatic cancer and bone tumors. Nonthermal HIFU bioeffects, including immune system modulation and targeted drug/gene therapy, are currently being explored in the preclinical realm, with an emphasis on leveraging these therapeutic effects in the care of the oncology patient. Although still in its early stages, the wide spectrum of therapeutic capabilities of HIFU offers great potential in the field of image-guided oncologic therapy. PMID:26622104

  12. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    PubMed

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  13. Transrectal ultrasonography-guided biopsy does not reliably identify dominant cancer location in men with low-risk prostate cancer.

    PubMed

    Washington, Samuel L; Bonham, Michael; Whitson, Jared M; Cowan, Janet E; Carroll, Peter R

    2012-07-01

    Study Type - Diagnostic (exploratory cohort) Level of Evidence 2b What's known on the subject? and What does the study add? The widespread use of serum PSA testing followed by TRUS-guided biopsy have resulted in profound prostate cancer stage migration with many patients presenting with focal rather than multifocal disease. There is increasing interest in the use of focal rather than whole-gland treatment. However, current biopsy schemes may still miss cancer or, even when cancer is identified, its extent or grade might not be accurately characterized. In order for focal therapy to be effective, the area of highest tumour volume and/or grade needs to localized accurately. The aim of this study was to assess how well biopsy, as currently performed, locates the focus of highest prostate cancer volume and/or grade. To evaluate the ability of transrectal ultrasonography (TRUS)-guided extended core biopsy to identify the dominant tumour accurately in men with early stage prostate cancer. Patients with early stage, low-risk prostate cancer who subsequently underwent radical prostatectomy (RP) and had complete surgical specimens were identified. Re-review was performed by a single uropathologist using ImageJ software to identify tumour location, dominant grade (DG) and dominant volume (DV). Pathology findings were then compared with biopsy results. A total of 51 men with early stage, low-risk prostate cancer, who had undergone RP, had complete specimens for review and a median of 15 biopsy cores taken for diagnosis and grading. Sixteen men had a single diagnostic biopsy, 21 had one repeat biopsy, and 14 had two or more repeat biopsies. Compared with surgical findings, biopsy correctly identified the sextant with the largest tumour volume in 55% (95% CI 0.5-0.6) of specimens and the highest grade in 37% (95 CI 0.3-0.5). No demographic or clinical factors were significantly associated with identification of DG. Interval between last biopsy and RP, total tissue length taken

  14. The Role of Contrast-Enhanced Ultrasound in Selection Indication and Improveing Diagnosis for Transthoracic Biopsy in Peripheral Pulmonary and Mediastinal Lesions

    PubMed Central

    Wang, Song; Yang, Wei; Zhang, Hui; Xu, Qian; Yan, Kun

    2015-01-01

    Objective. To investigate the value of contrast-enhanced ultrasound (CEUS) in transthoracic biopsy of peripheral lung and mediastinal lesions. Methods. Of 142 patients, 82 patients received CEUS before biopsy and were defined as CEUS group. The remaining 60 patients only underwent conventional ultrasound (US) before biopsy and were served as US group. The information of CEUS was used for selecting indication and instructing biopsy. The imaging features, number of punctures, diagnostic successful rate, and complication rate between the two groups were compared. Results. Necrosis was demonstrated in 43.9% of the lesions in CEUS group and in 6.7% of US group (P < 0.001). Detection rate of lesion hidden in pulmonary atelectasis in CEUS group was 13.4%, which was statistically higher than 1.7% of US group (P = 0.013). The diagnostic success rate was 96.3% for CEUS group and 80% for US group, respectively (P = 0.002). The average number of punctures was 2.5 ± 0.7 and 2.6 ± 0.6, respectively. There was no significant difference in complications between CEUS group and US group. Conclusions. CEUS could play an important role in selecting proper indication and improving diagnostic accuracy rate of lung biopsy. PMID:26090391

  15. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  16. Learning, techniques, and complications of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline.

    PubMed

    Polkowski, M; Larghi, A; Weynand, B; Boustière, C; Giovannini, M; Pujol, B; Dumonceau, J-M

    2012-02-01

    This article is the second of a two-part publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided Trucut biopsy. The first part (the Clinical Guideline) focused on the results obtained with EUS-guided sampling, and the role of this technique in patient management, and made recommendations on circumstances that warrant its use. The current Technical Guideline discusses issues related to learning, techniques, and complications of EUS-guided sampling, and to processing of specimens. Technical issues related to maximizing the diagnostic yield (e.g., rapid on-site cytopathological evaluation, needle diameter, microcore isolation for histopathological examination, and adequate number of needle passes) are discussed and recommendations are made for various settings, including solid and cystic pancreatic lesions, submucosal tumors, and lymph nodes. The target readership for the Clinical Guideline mostly includes gastroenterologists, oncologists, internists, and surgeons while the Technical Guideline should be most useful to endoscopists who perform EUS-guided sampling. A two-page executive summary of evidence statements and recommendations is provided. © Georg Thieme Verlag KG Stuttgart · New York.

  17. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.

  18. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    PubMed

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  19. Ultrasound-guided greater occipital nerve blocks and pulsed radiofrequency ablation for diagnosis and treatment of occipital neuralgia.

    PubMed

    Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-09-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.

  20. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    PubMed Central

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778

  1. Ultrasound-Guided Percutaneous Thyroid Nodule Core Biopsy: Clinical Utility in Patients with Prior Nondiagnostic Fine-Needle Aspirate

    PubMed Central

    Vij, Abhinav; Seale, Melanie K.; Desai, Gaurav; Halpern, Elkan; Faquin, William C.; Parangi, Sareh; Hahn, Peter F.; Daniels, Gilbert H.

    2012-01-01

    Background Five percent to 20% of thyroid nodule fine-needle aspiration (FNA) samples are nondiagnostic. The objective of this study was to determine whether a combination of FNA and core biopsy (CFNACB) would yield a higher proportion of diagnostic readings compared with FNA alone in patients with a history of one or more prior nondiagnostic FNA readings. Methods We conducted a retrospective study of 90 core biopsies (CBs) performed in 82 subjects (55 women and 27 men) between 2006 and 2008 in an outpatient clinic. Results CFNACB yielded a diagnostic reading in 87%. The diagnostic reading yield of the CB component of CFNACB was significantly superior to the concurrent FNA component, with CB yielding a diagnosis in 77% of cases and FNA yielding a diagnosis in 47% (p<0.0001). The combination of CB and FNA had a higher diagnostic reading yield than either alone. In 69 nodules that had only one prior nondiagnostic FNA, CB was diagnostic in 74%, FNA was diagnostic in 52%, CFNACB was diagnostic in 87%, and CB performed significantly better than FNA (p=0.0135). In 21 nodules with two or more prior nondiagnostic FNAs, CFNACB and CB were diagnostic in 86%, FNA was diagnostic in 29%, and CB was significantly better than FNA (p=0.0005). Clinical, ultrasound, or histopathologic follow-up was available for 81% (73/90) of the CFNACB procedures. No subject with a benign CFNACB reading was diagnosed with thyroid malignancy in the follow-up period (range 4–37 months, mean 18 months), although one subject had minimal increase in nodule size and was awaiting repeat sonography at study conclusion. Conclusion Thyroid nodule CFNACB is safe and clinically useful in selected patients when a prior FNA reading is nondiagnostic. CFNACB is superior to either CB or FNA alone. CFNACB should be strongly considered as an alternative to surgery in individuals with two prior nondiagnostic FNAs. PMID:22304390

  2. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies.

    PubMed

    Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W

    2015-01-01

    Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (P<0.0001). The improvement was statistically significant for each individual radiologist. During the same time, the rate of pneumothorax requiring chest tube placement decreased from 15% to 7% (P = 0.065). No other major complications were identified. The proportion of tumor within the biopsy material was similar at 28% (23%-33%) and 35% (30%-40%) for 2007 and 2012, respectively. The number of cases with at least two blocks available for testing increased from 10.7% to 96.4% (P<0.0001). The effect of this multidisciplinary strategy to CT-guided lung biopsies was effective in

  3. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies

    PubMed Central

    Ferguson, Philip E.; Sales, Catherine M.; Hodges, Dalton C.; Sales, Elizabeth W.

    2015-01-01

    Background Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. Design This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Results Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9–1.1 cm) in 2007 to 2.5 cm (2.3–2.8 cm) in 2012 (P<0.0001). The improvement was statistically significant for each individual radiologist. During the same time, the rate of pneumothorax requiring chest tube placement decreased from 15% to 7% (P = 0.065). No other major complications were identified. The proportion of tumor within the biopsy material was similar at 28% (23%–33%) and 35% (30%–40%) for 2007 and 2012, respectively. The number of cases with at least two blocks available for testing increased from 10.7% to 96.4% (P<0.0001). Conclusions The effect of this multidisciplinary strategy to CT-guided

  4. Biopsy of small kidneys: A safe and a useful guide to potentially treatable kidney disease.

    PubMed

    El-Reshaid, Kamel; El-Reshaid, Wael; Al-Bader, Dalal; Varro, Jozsef; Madda, John; Sallam, Hosameldin Tawfik

    2017-01-01

    Over the past four years, all patients with unexplained rapid progression of their renal disease were subjected to kidney biopsy, despite their small size (<9 cm), to define its etiology. Children, pregnant women, morbidly obese patients, and those with an unstable cardiovascular state, septicemia, bleeding diathesis as well as those kidney size with size <6 cm were excluded from the study. Doppler ultrasound was used to exclude renovascular/ischemic nephropathy. The procedure was performed by an interventional radiologist using a biopsy gun technique and under ultrasound guidance. The actual diagnosis was established in 29 cases while seven had advanced sclerosing glomerulonephritis. Eleven cases had evidence of vasculitis, of which two were due to polyarteritis nodosa and two were due to crescentic immunoglobulin A disease. The remaining patients had a secondary form of focal segmental glomerulosclerosis (n = 4), interstitial nephritis (n = 4), malignant nephro-angiosclerosis (n = 2), and single patient with primary hyperoxaluria, light chain cast nephropathy, amyloidosis, and thrombotic microangiopathy. All, except eight with advanced glomerulosclerosis, had improved or became stable with specific treatment. Our study shows that biopsy of small-sized kidneys, in patients with unexplained renal deterioration, is safe, and its diagnostic value can improve their morbidity and even mortality.

  5. Ultrasound-guided thrombin injection of genicular artery pseudoaneurysm.

    PubMed

    Rachakonda, Aditya; Qato, Khalil; Khaddash, Tamim; Carroccio, Alfio; Pamoukian, Vicken; Giangola, Gary

    2015-07-01

    Pseudoaneurysm is a rare complication after arthroscopic procedures involving the knee. A 38-year-old man presented 1 month after right-knee arthroscopy with a 2-cm pulsating mass on the medial side of the right knee. Duplex ultrasound evaluation revealed 2.5 × 2.1-cm pseudoaneurysm just distal to the patella with arterialized flow communicating with the inferior medial genicular artery. Ultrasound-guided thrombin injection was performed in an office setting, and the resolution of active flow within the pseudoaneurysm was confirmed with duplex ultrasonography. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Ultrasound-Guided Regional Anesthesia Simulation Training: A Systematic Review.

    PubMed

    Chen, Xiao Xu; Trivedi, Vatsal; AlSaflan, AbdulHadi A; Todd, Suzanne Clare; Tricco, Andrea C; McCartney, Colin J L; Boet, Sylvain

    Ultrasound-guided regional anesthesia (UGRA) has become the criterion standard of regional anesthesia practice. Ultrasound-guided regional anesthesia teaching programs often use simulation, and guidelines have been published to help guide URGA education. This systematic review aimed to examine the effectiveness of simulation-based education for the acquisition and maintenance of competence in UGRA. Studies identified in MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and ERIC were included if they assessed simulation-based UGRA teaching with outcomes measured at Kirkpatrick level 2 (knowledge and skills), 3 (transfer of learning to the workplace), or 4 (patient outcomes). Two authors independently reviewed all identified references for eligibility, abstracted data, and appraised quality. After screening 176 citations and 45 full-text articles, 12 studies were included. Simulation-enhanced training improved knowledge acquisition (Kirkpatrick level 2) when compared with nonsimulation training. Seven studies measuring skill acquisition (Kirkpatrick level 2) found that simulation-enhanced UGRA training was significantly more effective than alternative teaching methods or no intervention. One study measuring transfer of learning into the clinical setting (Kirkpatrick level 3) found no difference between simulation-enhanced UGRA training and non-simulation-based training. However, this study was discontinued early because of technical challenges. Two studies examined patient outcomes (Kirkpatrick level 4), and one of these found that simulation-based UGRA training improved patient outcomes compared with didactic teaching. Ultrasound-guided regional anesthesia knowledge and skills significantly improved with simulation training. The acquired UGRA skills may be transferred to the clinical setting; however, further studies are required to confirm these changes translate to improved patient outcomes.

  7. Endoscopic ultrasound-guided transesophageal thoracentesis for minimal pleural effusion.

    PubMed

    Rana, Surinder Singh; Sharma, Ravi; Gupta, Rajesh

    2018-06-19

    Pleural effusion is a common finding both in patients with benign and malignant diseases of pleura and lung with diagnostic thoracentesis establishing the diagnosis in the majority of cases. The diagnostic thoracentesis can be done either blindly or under the guidance of ultrasound or computed tomography. However, minimal pleural effusion is difficult to sample even under image guidance. Endoscopic ultrasound (EUS) is known to detect smaller volume of pleural effusion and, thus, can help in guiding thoracentesis. To analyze the safety and efficacy of EUS-guided diagnostic thoracentesis in patients with undiagnosed minimal pleural effusion retrospectively. Retrospective analysis of the data of patients with minimal pleural effusion, who underwent EUS-guided transesophageal diagnostic thoracentesis over last 2 years, was performed. Thirteen patients (11 male; mean age 46.7 ± 16.2 years) with undiagnosed minimal pleural effusion underwent successful EUS-guided transesophageal diagnostic thoracentesis using a 22-G needle. Seven (53%) patients had fever on presentation whereas two presented with cough and loss of appetite. Eight to 54 mL fluid was aspirated with an attempt to completely empty the pleural cavity. There were no complications of the procedure. EUS-guided diagnostic thoracentesis is a safe and effective alternative for evaluating patients with minimal pleural effusion.

  8. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Influenceable and Avoidable Risk Factors for Systemic Air Embolism due to Percutaneous CT-Guided Lung Biopsy: Patient Positioning and Coaxial Biopsy Technique—Case Report, Systematic Literature Review, and a Technical Note

    PubMed Central

    2014-01-01

    Following the first case of a systemic air embolism due to percutaneous CT-guided lung biopsy in our clinic we analysed the literature regarding this matter in view of influenceable or avoidable risk factors. A systematic review of literature reporting cases of systemic air embolism due to CT-guided lung biopsy was performed to find out whether prone positioning might be a risk factor regarding this issue. In addition, a technical note concerning coaxial biopsy practice is presented. Prone position seems to have relevance for the development and/or clinical manifestation of air embolism due to CT-guided lung biopsy and should be considered a risk factor, at least as far as lesions in the lower parts of the lung are concerned. Biopsies of small or cavitary lesions in coaxial technique should be performed using a hemostatic valve. PMID:25431666

  10. 'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.

    PubMed

    Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao

    2015-04-01

    The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.

  11. Impact of axillary ultrasound and core needle biopsy on the utility of intraoperative frozen section analysis and treatment decision making in women with invasive breast cancer.

    PubMed

    Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B

    2012-09-01

    Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  13. The utility of ultrasound in patients with melanoma.

    PubMed

    Uren, Roger F; Sanki, Amira; Thompson, John F

    2007-11-01

    The highest quality gray-scale ultrasound images are obtained with high-frequency transducers; however, such high frequencies do not penetrate more than a few centimeters into body tissue. Fortunately, in patients with melanoma, the structures of interest are close to the skin surface, making them ideal targets for examination with high-resolution ultrasound. These include primary cutaneous melanomas, uveal melanomas and the regional lymph nodes draining the skin that lie in the axilla, groin, neck and other locations. Although ultrasound study of primary melanomas arising in the skin and eye has provided some insights, a major role for ultrasound has evolved recently, to provide early detection of metastatic melanoma in regional lymph nodes. Ultrasound is clearly superior to clinical palpation of the nodes during follow-up and, when combined with guided fine-needle biopsy, allows the earliest possible surgical intervention for regional nodal metastases. In the future the use of ultrasound contrast agents may improve the sensitivity of ultrasound in the detection of very small metastatic deposits.

  14. Diagnostic yield of computed tomography-guided bone biopsy and clinical outcomes of tuberculous and pyogenic spondylitis.

    PubMed

    Joo, Eun-Jeong; Yeom, Joon-Sup; Ha, Young Eun; Park, So Yeon; Lee, Chong-Suh; Kim, Eun-Sang; Kang, Cheol-In; Chung, Doo-Ryeon; Song, Jae-Hoon; Peck, Kyong Ran

    2016-07-01

    This study aimed to evaluate the efficacy of computed tomography (CT)-guided bone biopsy for the diagnosis of spinal infection and compared the clinical outcomes between tuberculous and pyogenic spinal infections. The retrospective cohort study included patients who received CT-guided bone biopsy at a tertiary hospital over the 13 years. Among 100 patients, 67 had pyogenic spondylitis and 33 had tuberculous spondylitis. Pathogens were isolated from bone specimens obtained by CT-guided biopsy in 42 cases, with diagnostic yields of 61% (20/33) for tuberculous spondylitis and 33% (22/67) for pyogenic spondylitis. For 36 culture-proven pyogenic cases, Staphylococcus aureus was the most commonly isolated organism. Patients with pyogenic spondylitis more frequently presented with fever accompanied by an increase in inflammatory markers than did those with tuberculosis. Among all patients who underwent surgery, the incidence of late surgery performed one month after diagnosis was higher in patients with tuberculous infection (56.3%) than in those with pyogenic disease (23.3%, p = 0.026). Results obtained by CT-guided bone biopsy contributed to prompt diagnoses of spinal infections, especially those caused by tuberculosis. Despite administration of anti-tuberculous agents, patients with tuberculous spondylitis showed an increased tendency to undergo late surgery.

  15. Systematic Assessment Reveals Lack of Understandability for Prostate Biopsy Online Patient Education Materials.

    PubMed

    Maciolek, Kimberly A; Jarrard, David F; Abel, E Jason; Best, Sara L

    2017-11-01

    To evaluate the accuracy, readability, understandability, and actionability of Internet patient education materials (PEM) about transrectal ultrasound-guided prostate biopsy. A comprehensive Internet search was performed to find PEM with pre- or postbiopsy instructions. PEM that were duplicates, government affiliated, international, or video based were excluded. Biopsy instructions were evaluated for accuracy and presence of essential topics. Readability was assessed via word count and Flesch-Kincaid Grade Level. Understandability and actionability were measured using the Patient Education Materials Assessment Tool (PEMAT). Effects of authorship and geographical variation were determined using Fischer exact and Kruskal-Wallis tests. We identified 148 unique PEM. Only 31 (21%) sites adhered to the recommended <8th grade reading level. Most PEM did not contain recommended graphics (14%), checklists (2%), or summaries (6%). The PEMAT understandability score for academic PEM was higher than private (P = .02) and unaffiliated PEM (P = .01). No websites had inaccurate content. Only 2 PEM sites (1%) included all essential content (stop anticoagulants, antibiotics, need for urinalysis, biopsy pain, when to resume activity, and bleeding complications). Few significant differences based on geographic region were observed for word count, readability, PEMAT scores, or content. Transrectal ultrasound-guided prostate biopsy PEM adhere poorly to guidelines for easy-to-understand materials. Most PEM lack vital information and are written at a reading level that is too complex for patient comprehension. The urology community can construct better websites by consulting PEM advisory materials and providing nontechnical language, figures, and specific instructions. Published by Elsevier Inc.

  16. Conventional Landmark-Guided Midline Versus Preprocedure Ultrasound-Guided Paramedian Techniques in Spinal Anesthesia.

    PubMed

    Kallidaikurichi Srinivasan, Karthikeyan; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2015-10-01

    Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of postdural puncture headache, paraesthesia, and spinal hematoma. We hypothesized that the routine use of a preprocedural ultrasound-guided paramedian technique for spinal anesthesia would reduce the number of passes required to achieve entry into the subarachnoid space when compared with the conventional landmark-guided midline approach. One hundred consenting patients scheduled for elective total joint replacements (hip and knee) were randomized into group C (conventional) and group P (preprocedural ultrasound-guided paramedian technique) with 50 in each group. The patients were blinded to the study group. All spinal anesthetics were administered by a consultant anesthesiologist. In group C, spinal anesthetic was done via the midline approach using clinically palpated landmarks. In group P, a preprocedural ultrasound scan was used to mark the paramedian insertion site, and spinal anesthetic was performed via the paramedian approach. The average number of passes (defined as the number of forward advancements of the spinal needle in a given interspinous space, i.e., withdrawal and redirection of spinal needle without exiting the skin) in group P was approximately 0.34 times that in group C, a difference that was statistically significant (P = 0.01). Similarly, the average number of attempts (defined as the number of times the spinal needle was withdrawn from the skin and reinserted) in group P was approximately 0.25 times that of group C (P = 0.0021). In group P, on an average, it took 81.5 (99% confidence interval, 68.4-97 seconds) seconds longer to identify the landmarks than in group C (P = 0.0002). All other parameters, including grading of palpated landmarks, time taken for spinal anesthetic injection, periprocedural pain scores, periprocedural patient discomfort visual analog scale score, conversion to general anesthetic, paresthesia, and radicular pain

  17. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  18. Endoscopic ultrasound elastography: Current status and future perspectives

    PubMed Central

    Cui, Xin-Wu; Chang, Jian-Min; Kan, Quan-Cheng; Chiorean, Liliana; Ignee, Andre; Dietrich, Christoph F

    2015-01-01

    Elastography is a new ultrasound modality that provides images and measurements related to tissue stiffness. Endoscopic ultrasound (EUS) has played an important role in the diagnosis and management of numerous abdominal and mediastinal diseases. Elastography by means of EUS examination can assess the elasticity of tumors in the proximity of the digestive tract that are hard to reach with conventional transcutaneous ultrasound probes, such as pancreatic masses and mediastinal or abdominal lymph nodes, thus improving the diagnostic yield of the procedure. Results from previous studies have promised benefits for EUS elastography in the differential diagnosis of lymph nodes, as well as for assessing masses with pancreatic or gastrointestinal (GI) tract locations. It is important to mention that EUS elastography is not considered a modality that can replace biopsy. However, it may be a useful adjunct, improving the accuracy of EUS-fine needle aspiration biopsy (EUS-FNAB) by selecting the most suspicious area to be targeted. Even more, it may be useful for guiding further clinical management when EUS-FNAB is negative or inconclusive. In the present paper we will discuss the current knowledge of EUS elastography, including the technical aspects, along with its applications in the differential diagnosis between benign and malignant solid pancreatic masses and lymph nodes, as well as its aid in the differentiation between normal pancreatic tissues and chronic pancreatitis. Moreover, the emergent indication and future perspectives are summarized, such as the benefit of EUS elastography in EUS-guided fine needle aspiration biopsy, and its uses for characterization of lesions in liver, biliary tract, adrenal glands and GI tract. PMID:26715804

  19. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    PubMed

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  20. Stereotactic (Mammographically Guided) Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  1. Comparative study between ultrasound-guided fine needle aspiration cytology of axillary lymph nodes and sentinel lymph node histopathology in early-stage breast cancer

    PubMed Central

    Cardoso-Coelho, Lívio Portela; Borges, Rafael Soares; Alencar, Airlane Pereira; Cardoso-Campos-Verdes, Larysse Maira; da Silva-Sampaio, João Paulo; Borges, Umbelina Soares; Gebrim, Luiz Henrique; da Silva, Benedito Borges

    2017-01-01

    The replacement of sentinel lymph node biopsy (SNB) by ultrasound-guided fine-needle aspiration (US-guided FNA) cytology of axillary lymph nodes is controversial, despite the simplicity and reduced cost of the latter. In the present study, US-guided FNA was performed in 27 patients with early-stage breast cancer for comparison with SNB. Data were analyzed by calculation of sample proportions. Tumor subtypes included invasive ductal carcinoma (85%), invasive lobular carcinoma (7%), and tubular and metaplastic carcinoma (4%). FNA had a sensitivity of 45%, specificity of 100%, positive predictive value of 100% and a negative predictive value of 73%. Axillary lymph node cytology obtained by US guided-FNA in patients with breast cancer had a specificity similar to that of sentinel lymph node histopathology in the presence of axillary node metastases. However, when lymph node cytology is negative, it does not exclude the existence of metastatic implants, due to its low sensitivity in comparison to sentinel lymph node histopathology. PMID:28521436

  2. Utility of core biopsy with concurrent ROSE FNA in the diagnosis of pancreatic tumor-does the biopsy add any diagnostic benefit?

    PubMed

    Yan, Lei; Ikemura, Kenji; Park, Ji-Weon

    2018-02-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and endoscopic ultrasound-guided core-needle biopsy (EUS-CNB) are widely used for diagnosis of pancreatic tumors. The aim of our study was to compare the diagnostic performance of ROSE EUS-FNA and EUS-CNB for diagnosis of pancreatic malignancy during the same EUS. Patients who underwent both FNA and CNB during the same EUS for pancreatic solid lesion were reviewed retrospectively. Sample adequacy, diagnostic yield (defined as percentage of definitive diagnosis), sensitivity and specificity for malignancy were compared between FNA and CNB. A total of 48 patients with solid pancreatic lesions were evaluated. The proportions of adequate samples were 48/48 (100%) for FNA and 45/48 (93.7%) for core biopsy (P = .24). The diagnostic yield was 42/48 (87.5%) and 33/48 (68.7%) for FNA and CNB respectively (P = .046). The incremental increase in diagnostic yield by combining both methods was 2/48 (4%). The diagnostic yield for malignancy was 30/32 (93.7%) for FNA and 23/32 (71.8%) for CNB (P = .043). The sensitivity for the diagnosis of malignancy for FNA and CNB were 90.6% and 69%, respectively (P = .045). The specificity was 100% for both methods. The sensitivity for diagnosing malignancy increased to 93.8% when the two methods were combined. The difference in diagnostic yield was not associated with lesion size or location. EUS-guided FNA is a superior method of assessing solid pancreatic lesion and pancreatic malignancy with better diagnostic yield and higher sensitivity than EUS-CNB. © 2017 Wiley Periodicals, Inc.

  3. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    PubMed

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. In-line positioning of ultrasound images using wireless remote display system with tablet computer facilitates ultrasound-guided radial artery catheterization.

    PubMed

    Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo

    2016-02-01

    Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.

  5. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    PubMed

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu

    2016-02-15

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reportsmore » were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.« less

  7. Randomized comparison of power Doppler ultrasonography-guided core-needle biopsy with open surgical biopsy for the characterization of lymphadenopathies in patients with suspected lymphoma.

    PubMed

    Pugliese, Novella; Di Perna, M; Cozzolino, I; Ciancia, G; Pettinato, G; Zeppa, P; Varone, V; Masone, S; Cerchione, C; Della Pepa, R; Simeone, L; Giordano, C; Martinelli, V; Salvatore, C; Pane, F; Picardi, M

    2017-04-01

    The sensitivity of lymph node core-needle biopsy under imaging guidance requires validation. We employed power Doppler ultrasonography (PDUS) to select the lymph node most suspected of malignancy and to histologically characterize it through the use of large cutting needle. Institutional review board approval and informed consent were obtained for this randomized clinical trial. In a single center between 1 January 2009 and 31 December 2015, patients with lymph node enlargement suspected for lymphoma were randomly assigned (1:1) to biopsy with either standard surgery or PDUS-guided 16-gauge modified Menghini needle. The primary endpoint was the superiority of sensitivity for the diagnosis of malignancy for core-needle cutting biopsy (CNCB). Secondary endpoints were times to biopsy, complications, and costs. A total of 376 patients were randomized into the two arms and received allocated biopsy. However, four patients undergoing CNCB were excluded for inadequate samples; thus, 372 patients were analyzed. Sensitivity for the detection of malignancy was significantly better for PDUS-guided CNCB [98.8%; 95% confidence interval (CI), 95.9-99.9] than standard biopsy (88.7%; 95% CI, 82.9-93; P < 0.001). For all secondary endpoints, the comparison was significantly disadvantageous for conventional approach. In particular, estimated cost per biopsy performed with standard surgery was 24-fold higher compared with that performed with CNCB. The presence of satellite enlarged reactive and/or necrotic lymph nodes may impair the success of an open surgical biopsy (OSB). PDUS and CNCB with adequate gauge are diagnostic tools that enable effective, safe, fast, and low-cost routine biopsy for patients with suspected lymphoma, avoiding psychological and physical pain of an unnecessary surgical intervention.

  8. Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays

    DTIC Science & Technology

    2001-10-25

    81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased

  9. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    PubMed

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  10. [Ultrasound-guided rectus sheath block for upper abdominal surgery].

    PubMed

    Osaka, Yoshimune; Kashiwagi, Masanori; Nagatsuka, Yukio; Oosaku, Masayoshi; Hirose, Chikako

    2010-08-01

    Upper abdominal surgery leads to severe postoperative pain. Insufficient postoperative analgesia accompanies a high incidence of complications. Therefore, postoperative analgesia is very important. The epidural analgesia has many advantages. However it has a high risk of epidural hematoma in anticoagulated patients. Rectus sheath block provided safer and more reliable analgesia in recent years, by the development of ultrasound tools. We experienced two cases of the rectus sheath block in upper abdominal surgery under ultrasound guidance. Ultrasound guided rectus sheath block can reduce the risk of peritoneal puncture, bleeding, and other complications. Rectus sheath block is very effective to reduce postoperative pain in upper abdominal surgery as an alternative method to epidural anesthesia in anticoagulated patients.

  11. [Renal biopsy in the lateral position in high risk patients: an opportunity to take advantage of].

    PubMed

    Dugo, Mauro; Brisotto, Elisa; Vitturi, Nicola; Pasi, Alessandra; Mastrosimone, Stefania; Farneti, Fabrizio; Mangino, Margherita; Virgilio, Bice; Brunello, Anna; Pastori, Giordano; Mazzoli, Matteo; Laurino, Licia; Cova, Giandavide; Beniamin, Francesco; Maresca, Maria Cristina

    2015-01-01

    Percutaneous ultrasound-guided renal biopsy (RB) is the gold standard for diagnosis of renal diseases. The standard procedure involves biopsy in the prone position (PP) for the native kidneys. In high risk patients, transjugular and laparoscopic RB have been proposed. In patients suffering from obesity or respiratory diseases, the RB of the native kidney in the supine anterolateral position (SALP) represents an alternative to these invasive and expensive methods. We illustrate the technique of execution of RB in the lateral position (LP) on native kidneys. The procedure is safe, effective and has reduced the path travelled by the needle biopsy compared with PP and SALP.

  12. [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

    PubMed

    Jung, E M; Clevert, D A

    2018-06-01

    Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.

  13. Lung cancer diagnosis and staging with endobronchial ultrasound-guided transbronchial needle aspiration compared with conventional approaches: an open-label, pragmatic, randomised controlled trial

    PubMed Central

    Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M

    2015-01-01

    Summary Background The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. Methods In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Findings Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14–15) than with CDS (29 days; 23–35) resulting in a hazard ratio of 1·98, (1·39–2·82, p<0·0001). One patient in each group had a pneumothorax from a CT-guided biopsy sample; the patient from the CDS group needed intercostal drainage

  14. Percutaneous CT-Guided Biopsies of the Cervical Spine: Technique, Histopathologic and Microbiologic Yield, and Safety at a Single Academic Institution.

    PubMed

    Wiesner, E L; Hillen, T J; Long, J; Jennings, J W

    2018-05-01

    Cervical spine biopsies can be challenging due to the anatomy and the adjacent critical structures. Percutaneous image-guided biopsies can obviate the need for an open biopsy, however there have been few studies looking at the approaches, safety, and efficacy of percutaneous cervical spine biopsies. This retrospective study evaluated technical considerations, histopathologic and microbiologic yield, and safety in CT-guided cervical bone biopsies. A retrospective review of cervical bone and/or bone/disc biopsies performed from January 2010 to January 2017 was included in this study. Clinical diagnosis and indication, patient demographics, biopsy location, biopsy needle type, technical approach, lesion size, dose-length product, conscious sedation details, complications, and diagnostic histopathologic and/or microbiologic yield were recorded for each case and summarized. A total of 73 patients underwent CT-guided cervical bone biopsies. Fifty-three percent (39/73) were for clinical/imaging concern for infection and 47% (34/73) were for primary tumors or metastatic disease. Thirty-four percent (25/73) were of the inferior cervical spine (ie, C6 and C7). A sufficient sample was obtained for histopathologic and microbiologic analyses in 96% (70/73) of the biopsies. Forty-six percent (18/39) of those samples taken for infection had positive cultures. Two intraprocedural complications occurred in which the patients became hypotensive during the procedure without long-term complications. Percutaneous CT-guided biopsy of the cervical spine is an effective and safe procedure with high diagnostic yield and can obviate open procedures for histopathologic and microbiologic analyses of patients with clinical and imaging findings concerning for infection or primary and metastatic osseous lesions. © 2018 by American Journal of Neuroradiology.

  15. Computed tomography-guided bone biopsies for evaluation of proliferative vertebral lesions in two boa constrictors (Boa constrictor imperator).

    PubMed

    Di Girolamo, Nicola; Selleri, Paolo; Nardini, Giordano; Corlazzoli, Daniele; Fonti, Paolo; Rossier, Christophe; Della Salda, Leonardo; Schilliger, Lionel; Vignoli, Massimo; Bongiovanni, Laura

    2014-12-01

    Two boa constrictors (Boa constrictor imperator) presented with paresis of the trunk originating cranial to the cloaca. Radiographs were consistent with proliferative bone lesions involving several vertebrae. Computed tomography (CT) demonstrated the presence of lytic/expansile lesions. Computed tomography-guided biopsies of the lesions were performed without complications. Histology was consistent with bacterial osteomyelitis and osteoarthritis. Gram-negative bacteria (Salmonella sp. and Pseudomonas sp.) were isolated from cultures of the biopsies. Medical treatment with specific antibiotics was attempted for several weeks in both cases without clinical or radiographic improvements. The animals were euthanized, and necropsy confirmed the findings observed upon CT. To the authors' knowledge, this is the first report of the use of CT-guided biopsies to evaluate proliferative vertebral lesions in snakes. In the present report, CT-guided biopsies were easily performed, and both histologic and microbiologic results were consistent with the final diagnosis.

  16. Accuracy of pre-operative hysteroscopic guided biopsy for predicting final pathology in uterine malignancies.

    PubMed

    Martinelli, Fabio; Ditto, Antonino; Bogani, Giorgio; Signorelli, Mauro; Chiappa, Valentina; Lorusso, Domenica; Haeusler, Edward; Raspagliesi, Francesco

    2017-07-01

    To evaluate concordance (C) between pre-operative hysteroscopic-directed sampling and final pathology in uterine cancers. A retrospective cross-sectional evaluation of prospectively collected data of women who underwent hysterectomy for uterine malignancies and a previous hysteroscopic-guided biopsy was performed. Diagnostic concordance between pre-operative (hysteroscopic biopsy) and postoperative (uterine specimen) histology was evaluated. In endometrioid-endometrial cancers cases Kappa (k) statistics was applied to evaluate agreement for grading (G) between the preoperative and final pathology. A total 101 hysterectomies for uterine malignancies were evaluated. There were 23 non-endometrioid cancers: 7 serous (C:5/7, 71.4%); 10 carcinosarcomas (C:7/10, 70%, remaining 3 cases only epithelial component diagnosed); 3 clear cell (C:3/3, 100%); 3 sarcomas (C:3/3, 100%). In 78 cases an endometrioid endometrial cancer was found. In 63 cases there was a histological C (63/78, 80.8%) between hysteroscopic-guided biopsy and final pathology, while in 15 cases (19.2%) only hyperplasia (with/without atypia) was found preoperatively. Overall accuracy to detect endometrial cancer was 80.2%. In 50 out of 63 endometrial cancers (79.4%) grading was concordant. The overall level of agreement between preoperative and postoperative grading was "substantial" according to Kappa (k) statistics (k 0.64; 95% CI: 0.449-0.83; p < 0.001), as well as for G1 (0.679; 95% CI: 0.432-0.926; p < 0.001) and G3 (0.774; 94% CI: 0.534-1; p < 0.001), while for G2 (0.531; 95% CI: 0.286-0.777; p < 0.001) it was moderate. In our series we found an 80% C between pre-operative hysteroscopic-guided biopsy and final pathology, in uterine malignancies. Moreover, hysteroscopic biopsy accurately predicted endometrial cancer in 80% of cases and "substantially" predicted histological grading. Hysteroscopic-guided uterine sampling could be a useful tool to tailor treatment in patients with uterine

  17. Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

    PubMed

    Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J

    2006-01-01

    Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.

  18. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  19. Teaching medical students ultrasound-guided vascular access - which learning method is best?

    PubMed

    Lian, Alwin; Rippey, James C R; Carr, Peter J

    2017-05-15

    Ultrasound is recommended to guide insertion of peripheral intravenous vascular cannulae (PIVC) where difficulty is experienced. Ultrasound machines are now common-place and junior doctors are often expected to be able to use them. The educational standards for this skill are highly varied, ranging from no education, to self-guided internet-based education, to formal, face-to-face traditional education. In an attempt to decide which educational technique our institution should introduce, a small pilot trial comparing educational techniques was designed. Thirty medical students were enrolled and allocated to one of three groups. PIVC placing ability was then observed, tested and graded on vascular access phantoms. The formal, face-to-face traditional education was rated best by the students, and had the highest success rate in PIVC placement, the improvement statistically significant compared to no education (p = 0.01) and trending towards significance when compared to self-directed internet-based education (p<0.06). The group receiving traditional face-to-face teaching on ultrasound-guided vascular access, performed significantly better than those not receiving education. As the number of ultrasound machines in clinical areas increases, it is important that education programs to support their safe and appropriate use are developed.

  20. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    NASA Astrophysics Data System (ADS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-07-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.

  1. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    PubMed

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  2. A cMUT probe for ultrasound-guided focused ultrasound targeted therapy.

    PubMed

    Gross, Dominique; Coutier, Caroline; Legros, Mathieu; Bouakaz, Ayache; Certon, Dominique

    2015-06-01

    Ultrasound-mediated targeted therapy represents a promising strategy in the arsenal of modern therapy. Capacitive micromachined ultrasonic transducer (cMUT) technology could overcome some difficulties encountered by traditional piezoelectric transducers. In this study, we report on the design, fabrication, and characterization of an ultrasound-guided focused ultrasound (USgFUS) cMUT probe dedicated to preclinical evaluation of targeted therapy (hyperthermia, thermosensitive liposomes activation, and sonoporation) at low frequency (1 MHz) with simultaneous ultrasonic imaging and guidance (15 to 20 MHz). The probe embeds two types of cMUT arrays to perform the modalities of targeted therapy and imaging respectively. The wafer-bonding process flow employed for the manufacturing of the cMUTs is reported. One of its main features is the possibility of implementing two different gap heights on the same wafer. All the design and characterization steps of the devices are described and discussed, starting from the array design up to the first in vitro measurements: optical (microscopy) and electrical (impedance) measurements, arrays' electroacoustic responses, focused pressure field mapping (maximum peak-to-peak pressure = 2.5 MPa), and the first B-scan image of a wire-target phantom.

  3. Ultrasound-Guided Cryoanalgesia of Peripheral Nerve Lesions.

    PubMed

    Djebbar, Sahlya; Rossi, Ignacio M; Adler, Ronald S

    2016-11-01

    The real-time nature of ultrasound makes it ideally suited to provide guidance for a variety of musculoskeletal interventional procedures involving peripheral nerves. Continuous observation of the needle ensures proper placement and allows continuous monitoring when performing localized ablative therapy and therefore more accurate positioning of a cryoprobe, use of smaller needles, as well as access to small structures. We describe our experience performing cryoablative procedures. Patients undergoing cryoneurolysis have largely reported varying degrees of long-term pain relief and improvement in function; no serious complications have yet been identified. Ultrasound-guided cryoneurolysis can provide a useful, safe alternative to other ablative techniques to achieve long-term analgesia from painful peripheral nerve lesions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Transcranial MR-Guided Focused Ultrasound: A Review of the Technology and Neuro Applications

    PubMed Central

    Ghanouni, Pejman; Pauly, Kim Butts; Elias, W. Jeff; Henderson, Jaimie; Sheehan, Jason; Monteith, Stephen; Wintermark, Max

    2015-01-01

    MR guided focused ultrasound is a new, minimally invasive method of targeted tissue thermal ablation that may be of use to treat central neuropathic pain, essential tremor, Parkinson tremor, and brain tumors. The system has also been used to temporarily disrupt the blood-brain barrier to allow targeted drug delivery to brain tumors. This article reviews the physical principles of MR guided focused ultrasound and discusses current and potential applications of this exciting technology. PMID:26102394

  5. Ultrasound-Guided Vascular Access Simulator for Medical Training: Proposal of a Simple, Economic and Effective Model.

    PubMed

    Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio

    2017-03-01

    To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.

  6. Determinants of complications after multiple transrectal core biopsies of the prostate.

    PubMed

    Norberg, M; Holmberg, L; Häggman, M; Magnusson, A

    1996-01-01

    Transrectal ultrasound-guided biopsies of the prostate were performed on 347 consecutive men. All patients were given prophylactic antibiotics. The first 199 patients received 400 mg norfloxacin immediately after the biopsies were performed and 400 mg the same evening. The second group of 148 patients received 400 mg of norfloxacin 1 h before the examination followed by five doses administered twice daily. A total of 15 major complications were noted. In the first group the complication rate was 6.5% and in the second group 1.4%. The different regimes of prophylactic antibiotic treatment were the only parameters shown to have a statistically significant impact on the complication rate. The number of complications decreased, but were not eliminated, when prophylactic treatment with norfloxacin was given before the biopsies were taken and continued for a total of 3 days.

  7. Navigated MRI-guided liver biopsies in a closed-bore scanner: experience in 52 patients.

    PubMed

    Moche, Michael; Heinig, Susann; Garnov, Nikita; Fuchs, Jochen; Petersen, Tim-Ole; Seider, Daniel; Brandmaier, Philipp; Kahn, Thomas; Busse, Harald

    2016-08-01

    To evaluate clinical effectiveness and diagnostic efficiency of a navigation device for MR-guided biopsies of focal liver lesions in a closed-bore scanner. In 52 patients, 55 biopsies were performed. An add-on MR navigation system with optical instrument tracking was used for image guidance and biopsy device insertion outside the bore. Fast control imaging allowed visualization of the true needle position at any time. The biopsy workflow and procedure duration were recorded. Histological analysis and clinical course/outcome were used to calculate sensitivity, specificity and diagnostic accuracy. Fifty-four of 55 liver biopsies were performed successfully with the system. No major and four minor complications occurred. Mean tumour size was 23 ± 14 mm and the skin-to-target length ranged from 22 to 177 mm. In 39 cases, access path was double oblique. Sensitivity, specificity and diagnostic accuracy were 88 %, 100 % and 92 %, respectively. The mean procedure time was 51 ± 12 min, whereas the puncture itself lasted 16 ± 6 min. On average, four control scans were taken. Using this navigation device, biopsies of poorly visible and difficult accessible liver lesions could be performed safely and reliably in a closed-bore MRI scanner. The system can be easily implemented in clinical routine workflow. • Targeted liver biopsies could be reliably performed in a closed-bore MRI. • The navigation system allows for image guidance outside of the scanner bore. • Assisted MRI-guided biopsies are helpful for focal lesions with a difficult access. • Successful integration of the method in clinical workflow was shown. • Subsequent system installation in an existing MRI environment is feasible.

  8. A multimodal image guiding system for Navigated Ultrasound Bronchoscopy (EBUS): A human feasibility study

    PubMed Central

    Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav

    2017-01-01

    Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758

  9. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  10. MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garnon, J., E-mail: juliengarnon@gmail.com; Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com; Caudrelier J, J., E-mail: caudjean@yahoo.fr

    2016-05-15

    ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinummore » (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.« less

  11. A Randomized Double-Blinded Trial on the Effects of Ultrasound Transducer Orientation on Teaching and Learning Ultrasound-Guided Regional Anesthesia.

    PubMed

    Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R

    2016-07-01

    Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.

  12. Biopsy guided by dermoscopy in cutaneous pigmented lesion - Case report*

    PubMed Central

    Bomm, Lislaine; Benez, Marcela Duarte Villela; Maceira, Juan Manuel Piñeiro; Succi, Isabel Cristina Brasil; Scotelaro, Maria de Fatima Guimarães

    2013-01-01

    It may be clinically difficult to differentiate early-stage melanoma from benign tumors, specially pigmented seborrheic keratosis. Dermoscopy can help; however, the findings are not always conclusive. Therefore, histopathology may be necessary for a correct diagnosis. We describe a melanocytic lesion with dubious clinic and dermoscopic findings. An incisional biopsy of a suspicious area, guided by dermoscopy, was performed to clarify the findings. PMID:23539018

  13. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    PubMed

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason < 7 group and Gleason > 7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  14. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    PubMed Central

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  15. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advancedmore » techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.« less

  16. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures.

    PubMed

    Barile, Antonio; La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-09-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases.

  17. Palpation- and ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    da Cunha, Anderson F; Strain, George M; Rademacher, Nathalie; Schnellbacher, Rodney; Tully, Thomas N

    2013-01-01

    To compare palpation-guided with ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots. Prospective randomized experimental trial. Eighteen adult Hispaniolan Amazon parrots (Amazona ventralis) weighing 252-295 g. After induction of anesthesia with isoflurane, parrots received an injection of lidocaine (2 mg kg(-1)) in a total volume of 0.3 mL at the axillary region. The birds were randomly assigned to equal groups using either palpation or ultrasound as a guide for the brachial plexus block. Nerve evoked muscle potentials (NEMP) were used to monitor effectiveness of brachial plexus block. The palpation-guided group received the local anesthetic at the space between the pectoral muscle, triceps, and supracoracoideus aticimus muscle, at the insertion of the tendons of the caudal coracobrachial muscle, and the caudal scapulohumeral muscle. For the ultrasound-guided group, the brachial plexus and the adjacent vessels were located with B-mode ultrasonography using a 7-15 MHz linear probe. After location, an 8-5 MHz convex transducer was used to guide injections. General anesthesia was discontinued 20 minutes after lidocaine injection and the birds recovered in a padded cage. Both techniques decreased the amplitude of NEMP. Statistically significant differences in NEMP amplitudes, were observed within the ultrasound-guided group at 5, 10, 15, and 20 minutes after injection and within the palpation-guided group at 10, 15, and 20 minutes after injection. There was no statistically significant difference between the two groups. No effect on motor function, muscle relaxation or wing droop was observed after brachial plexus block. The onset of the brachial plexus block tended to be faster when ultrasonography was used. Brachial plexus injection can be performed in Hispaniolan Amazon parrots and nerve evoked muscle potentials were useful to monitor the effects on nerve conduction in this avian species. Neither technique produced an effective block at the

  18. Ultrasound-Guided Fine-Needle Aspiration of Non-palpable and Suspicious Axillary Lymph Nodes with Subsequent Removal after Tattooing: False-Negative Results and Concordance with Sentinel Lymph Nodes.

    PubMed

    Kim, Won Hwa; Kim, Hye Jung; Jung, Jin Hyang; Park, Ho Yong; Lee, Jeeyeon; Kim, Wan Wook; Park, Ji Young; Cheon, Hyejin; Lee, So Mi; Cho, Seung Hyun; Shin, Kyung Min; Kim, Gab Chul

    2017-11-01

    Ultrasonography-guided fine-needle aspiration (US-guided FNA) for axillary lymph nodes (ALNs) is currently used with various techniques for the initial staging of breast cancer and tagging of ALNs. With the implementation of the tattooing of biopsied ALNs, the rate of false-negative results of US-guided FNA for non-palpable and suspicious ALNs and concordance with sentinel lymph nodes were determined by node-to node analyses. A total of 61 patients with breast cancer had negative results for metastasis on US-guided FNA of their non-palpable and suspicious ALNs. The biopsied ALNs were tattooed with an injection of 1-3 mL Charcotrace (Phebra, Lane Cove West, Australia) ink and removed during sentinel lymph node biopsy or axillary dissection. We determined the rate of false-negative results and concordance with the sentinel lymph nodes by a retrospective review of surgical and pathologic findings. The association of false-negative results with clinical and imaging factors was evaluated using logistic regression. Of the 61 ALNs with negative results for US-guided FNA, 13 (21%) had metastases on final pathology. In 56 of 61 ALNs (92%), tattooed ALNs corresponded to the sentinel lymph nodes. Among the 5 patients (8%) without correspondence, 1 patient (2%) had 2 metastatic ALNs of 1 tattooed node and 1 sentinel lymph node. In multivariate analysis, atypical cells on FNA results (odds ratio = 20.7, p = 0.040) was independently associated with false-negative FNA results. False-negative ALNs after US-guided FNA occur at a rate of 21% and most of the tattooed ALNs showed concordance with sentinel lymph nodes. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  20. Transvaginal ultrasound-guided embryo transfer in IVF.

    PubMed

    Larue, L; Keromnes, G; Massari, A; Roche, C; Moulin, J; Gronier, H; Bouret, D; Cassuto, N G; Ayel, J P

    2017-05-01

    To determine whether transvaginal ultrasound-guided embryo transfer is a technique that can be used routinely, whether it improves IVF outcomes and whether it makes difficult transfers easier and more successful. Non-randomized retrospective study conducted between 2012 and 2016 in the fertility center of the Diaconesses-Croix St-Simon hospital group. The outcomes of 3910 transfers, performed by 5 senior operators, under transabdominal ultrasound guidance are compared with those of 800 transfers, performed by 1 senior operator under transvaginal ultrasound guidance. The criteria studied are the feasibility of the technique and the percentage of pregnancies per transfer in the two populations described, as well as in the difficult and very difficult transfer populations. All the transfers were feasible under transvaginal ultrasound guidance without the use of forceps or additional instruments. The percentage of pregnancies per transfer is significantly increased, when the transfer is performed under transvaginal ultrasound guidance compared with that performed under transabdominal ultrasound guidance, in the general population (38%, n=800 vs 30%, n=3910; P 0.0004) and in the reference population characterized by age <38 years and >6 oocytes collected per puncture (45%, n=490 vs 36%, n=1968; P 0.002). The percentage of pregnancies per transfer (P/T) is not significantly different in the populations of easy transfers (n 695, 38% P/T), difficult transfers (n 58, 46% P/T; P=ns) and very difficult transfers (n 47, 34% P/T; P=ns). Embryo transfer is a key stage in IVF, in which the quality of performance determines the outcome. In this study, transvaginal ultrasound guidance of the transfer, which is the reference procedure in gynaecological imaging, significantly increases the percentage of pregnancies per transfer, both in the general population and in the reference population, compared with transfers performed under transabdominal ultrasound guidance. Transvaginal

  1. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma.

    PubMed

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side ( P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  2. Rapid motion compensation for prostate biopsy using GPU.

    PubMed

    Shen, Feimo; Narayanan, Ramkrishnan; Suri, Jasjit S

    2008-01-01

    Image-guided procedures have become routine in medicine. Due to the nature of three-dimensional (3-D) structure of the target organs, two-dimensional (2-D) image acquisition is gradually being replaced by 3-D imaging. Specifically in the diagnosis of prostate cancer, biopsy can be performed using 3-D transrectal ultrasound (TRUS) image guidance. Because prostatic cancers are multifocal, it is crucial to accurately guide biopsy needles towards planned targets. Further the gland tends to move due to external physical disturbances, discomfort introduced by the procedure or intrinsic peristalsis. As a result the exact position of the gland must be rapidly updated so as to correspond with the originally acquired 3-D TRUS volume prior to biopsy planning. A graphics processing unit (GPU) is used in this study to compute rapid updates performing 3-D motion compensation via registration of the live 2-D image and the acquired 3-D TRUS volume. The parallel computational framework on the GPU is exploited resulting in mean compute times of 0.46 seconds for updating the position of a live 2-D buffer image containing 91,000 pixels. A 2x sub-sampling resulted in a further improvement to 0.19 seconds. With the increase in GPU multiprocessors and sub-sampling, we observe that real time motion compensation can be achieved.

  3. Endoscopic ultrasound (EUS) guided fine needle biopsy (FNB) with the Procore™ needle provides inadequate material for the histological diagnosis of early chronic pancreatitis.

    PubMed

    Iglesias García, Julio; Lariño-Noia, José; Abdulkader Nallib, Ihab; Lindkvist, Björn; Domínguez-Muñoz, J Enrique

    2018-05-03

    diagnosis of early chronic pancreatitis (CP) is hampered due to the low accuracy of current imaging techniques and the absence of methods for histological confirmation. We aimed to evaluate the efficacy of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for the histological diagnosis of early CP. a prospective, cross-sectional, single-center study was designed. Consecutive patients referred for EUS with a clinical suspicion of CP were evaluated for inclusion into the study. Inclusion criteria were age > 18 years and indeterminate EUS findings for the diagnosis of CP according to the Rosemont classification. EUS-FNB of the body of the pancreas was performed with Procore™ needles. Tissue samples were immersed into a methanol-based buffered preservative solution for cytohistological evaluation. The quality of the samples obtained and the histological findings were evaluated. Procedure-related complications were recorded. the study was stopped after eleven patients were included due to safety concerns and poor diagnostic yield. The mean age of the patients was 50.3 years (range 33-70 years) and six were male. Samples were of poor quality in five cases, but were sufficient for cell-block evaluation. An inflammatory infiltration with mild fibrosis was identified in two cases and neither inflammatory infiltration nor fibrosis was identified in three cases. With regard to the other six cases, isolated inflammatory cells were observed in one case, although the cellularity was poor and unsuitable for cytological evaluation in five cases. There was one major complication (9.1%) of acute pancreatitis that required hospitalization for 48 hours. EUS-FNB is technically feasible in patients with EUS findings categorized as indeterminate for a CP diagnosis. However, the diagnostic yield is poor and there is a non-negligible risk of complications.

  4. Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.

    PubMed

    Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu

    2015-11-01

    Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.

  5. Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe

    PubMed Central

    Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.

    2014-01-01

    Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628

  6. Ultrasound-guided piriformis muscle injection. A new approach.

    PubMed

    Bevilacqua Alén, E; Diz Villar, A; Curt Nuño, F; Illodo Miramontes, G; Refojos Arencibia, F J; López González, J M

    2016-12-01

    Piriformis syndrome is an uncommon cause of buttock and leg pain. Some treatment options include the injection of piriformis muscle with local anesthetic and steroids. Various techniques for piriformis muscle injection have been described. Ultrasound allows direct visualization and real time injection of the piriformis muscle. We describe 5 consecutive patients, diagnosed of piriformis syndrome with no improvement after pharmacological treatment. Piriformis muscle injection with local anesthetics and steroids was performed using an ultrasound technique based on a standard technique. All 5 patients have improved their pain measured by numeric verbal scale. One patient had a sciatic after injection that improved in 10 days spontaneously. We describe an ultrasound-guided piriformis muscle injection that has the advantages of being effective, simple, and safe. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Phase I/II prospective trial of cancer-specific imaging using ultrasound spectrum analysis tissue-type imaging to guide dose-painting prostate brachytherapy.

    PubMed

    Ennis, Ronald D; Quinn, S Aidan; Trichter, Frieda; Ryemon, Shannon; Jain, Anudh; Saigal, Kunal; Chandrashekhar, Sarayu; Romas, Nicholas A; Feleppa, Ernest J

    2015-01-01

    To assess the technical feasibility, toxicity, dosimetry, and preliminary efficacy of dose-painting brachytherapy guided by ultrasound spectrum analysis tissue-type imaging (TTI) in low-risk, localized prostate cancer. Fourteen men with prostate cancer who were candidates for brachytherapy as sole treatment were prospectively enrolled. Treatment planning goal was to escalate the tumor dose to 200% with a modest de-escalation of dose to remaining prostate compared with our standard. Primary end points included technical feasibility of TTI-guided brachytherapy and equivalent or better toxicity compared with standard brachytherapy. Secondary end points included dose escalation to tumor regions and de-escalated dose to nontumor regions on the preimplant plan, negative prostate biopsy at 2 years, and freedom from biochemical failure. Thirteen of fourteen men successfully completed the TTI-guided brachytherapy procedure for a feasibility rate of 93%. A software malfunction resulted in switching one patient from TTI-guided to standard brachytherapy. An average of 2.7 foci per patient was demonstrated and treated with an escalated dose. Dosimetric goals on preplan were achieved. One patient expired from unrelated causes 65 days after brachytherapy. Toxicity was at least as low as standard brachytherapy. Two-year prostate biopsies were obtained from six men; five (83%) were definitively negative, one showed evidence of disease with treatment effect, and none were positive. No patients experienced biochemical recurrence after a median followup of 31.5 (24-52) months. We have demonstrated that TTI-guided dose-painting prostate brachytherapy is technically feasible and results in clinical outcomes that are encouraging in terms of low toxicity and successful biochemical disease control. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  8. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    PubMed

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  9. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    PubMed

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  10. Gestrinone combined with ultrasound-guided aspiration and ethanol injection for treatment of chocolate cyst of ovary.

    PubMed

    Wu, Xiaoyun; Xu, Yun

    2015-05-01

    The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  11. Assessment of Prospectively Assigned Likert Scores for Targeted Magnetic Resonance Imaging-Transrectal Ultrasound Fusion Biopsies in Patients with Suspected Prostate Cancer.

    PubMed

    Costa, Daniel N; Lotan, Yair; Rofsky, Neil M; Roehrborn, Claus; Liu, Alexander; Hornberger, Brad; Xi, Yin; Francis, Franto; Pedrosa, Ivan

    2016-01-01

    We assess the performance of prospectively assigned magnetic resonance imaging based Likert scale scores for the detection of clinically significant prostate cancer, and analyze the pre-biopsy imaging variables associated with increased cancer detection using targeted magnetic resonance imaging-transrectal ultrasound fusion biopsy. In this retrospective review of prospectively generated data including men with abnormal multiparametric prostate magnetic resonance imaging (at least 1 Likert score 3 or greater lesion) who underwent subsequent targeted magnetic resonance imaging-transrectal ultrasound fusion biopsy, we determined the association between different imaging variables (Likert score, lesion size, lesion location, prostate volume, radiologist experience) and targeted biopsy positivity rate. We also compared the detection of clinically significant cancer according to Likert scale scores. Tumors with high volume (50% or more of any core) Gleason score 3+4 or any tumor with greater Gleason score were considered clinically significant. Each lesion served as the elementary unit for analysis. We used logistic regression for univariate and multivariate (stepwise selection) analysis to assess for an association between targeted biopsy positivity rate and each tested variable. The relationship between Likert scale and Gleason score was evaluated using the Spearman correlation coefficient. A total of 161 men with 244 lesions met the study eligibility criteria. Targeted biopsies diagnosed cancer in 41% (66 of 161) of the men and 41% (99 of 244) of the lesions. The Likert score was the strongest predictor of targeted biopsy positivity (OR 3.7, p <0.0001). Other imaging findings associated with a higher targeted biopsy positivity rate included smaller prostate volume (OR 0.7, p <0.01), larger lesion size (OR 2.2, p <0.001) and anterior location (OR 2.0, p=0.01). On multiple logistic regression analysis Likert score, lesion size and prostate volume were significant

  12. Analysis of costs of transrectal prostate biopsy.

    PubMed

    Fandella, Andrea

    2011-01-01

    Literature reports mortality and morbidity data from prostatic carcinoma which permit a better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. The aim of this work is to quantify the overall cost of transrectal ultrasound biopsy of the prostate (TRUSB) and to assess the economic impact of current procedures for diagnosing prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 2008. The following cost factors were evaluated: personnel, materials, maintenance/depreciation of the equipment, energy consumption, and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide, and to consider them in the wider framework of the economic effectiveness of strategies for early diagnosis of cancer of the prostate. The overall cost of TRUSB (8 samples) was EUR 249,000, obtained by adding together the costs of: personnel (EUR 160,000); materials (EUR 59,000); equipment maintenance and depreciation (EUR 12,400); energy consumption (EUR0,1); hospital overheads (EUR 17,500). With extended or saturation biopsies the cost increases for the more time needed by pathologists and can be calculated as EUR 300,000. The literature review points out TRUSB as an invasive tool for diagnosing prostatic carcinoma, clinically and economically controversial. Post-mortem data report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity rate from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, have a good probability of being positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the detection by digital exploration and/or positive transrectal ultrasound. CONCLUSIONS. Despite the severe

  13. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients

    PubMed Central

    Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-01-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173

  14. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    PubMed

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  15. Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP.

    PubMed

    Mora Soler, Ana María; Álvarez Delgado, Alberto; Piñero Pérez, María Concepción; Velasco-Guardado, Antonio; Marcos Prieto, Héctor; Rodríguez Pérez, Antonio

    2018-05-01

    endoscopic ultrasound-guided biliary drainage (EUS-BD) is an alternative to percutaneous trans-hepatic biliary drainage (PTBD) in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). this is a retrospective description of six cases of endoscopic ultrasound-guided biliary drainage via choledochoduodenostomy (EUCD), as well as the clinical characteristics, endoscopic procedure, complications and monitoring. all cases had malignant distal biliary obstruction. The procedure was concluded with good drainage in four out of six patients. Two late complications were recorded that were caused by stent migration and there were no deaths related with the procedure. The average monitoring period was six months. EUCD can be considered as a valid therapeutic choice in some selected cases and when performed by a team of expert endoscopists in cases of failed ERCP drainage or as an alternative to PTBD. However, the procedure has some associated complications.

  16. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    PubMed

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  17. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    PubMed

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p < 0.0001). When the thickness was greater or equal to 9.9 cm, drained volume was always more than 1000 ml. The measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  18. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures

    PubMed Central

    La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-01-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases. PMID:27302491

  19. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    PubMed

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  20. Magnetic Resonance (MR)-Guided Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  1. Autonomous surgical robotics using 3-D ultrasound guidance: feasibility study.

    PubMed

    Whitman, John; Fronheiser, Matthew P; Ivancevich, Nikolas M; Smith, Stephen W

    2007-10-01

    The goal of this study was to test the feasibility of using a real-time 3D (RT3D) ultrasound scanner with a transthoracic matrix array transducer probe to guide an autonomous surgical robot. Employing a fiducial alignment mark on the transducer to orient the robot's frame of reference and using simple thresholding algorithms to segment the 3D images, we tested the accuracy of using the scanner to automatically direct a robot arm that touched two needle tips together within a water tank. RMS measurement error was 3.8% or 1.58 mm for an average path length of 41 mm. Using these same techniques, the autonomous robot also performed simulated needle biopsies of a cyst-like lesion in a tissue phantom. This feasibility study shows the potential for 3D ultrasound guidance of an autonomous surgical robot for simple interventional tasks, including lesion biopsy and foreign body removal.

  2. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    PubMed

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  3. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    DTIC Science & Technology

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine (Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine (Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US

  4. TU-CD-BRB-12: Radiogenomics of MRI-Guided Prostate Cancer Biopsy Habitats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoyanova, R; Lynne, C; Abraham, S

    2015-06-15

    Purpose: Diagnostic prostate biopsies are subject to sampling bias. We hypothesize that quantitative imaging with multiparametric (MP)-MRI can more accurately direct targeted biopsies to index lesions associated with highest risk clinical and genomic features. Methods: Regionally distinct prostate habitats were delineated on MP-MRI (T2-weighted, perfusion and diffusion imaging). Directed biopsies were performed on 17 habitats from 6 patients using MRI-ultrasound fusion. Biopsy location was characterized with 52 radiographic features. Transcriptome-wide analysis of 1.4 million RNA probes was performed on RNA from each habitat. Genomics features with insignificant expression values (<0.25) and interquartile range <0.5 were filtered, leaving total of 212more » genes. Correlation between imaging features, genes and a 22 feature genomic classifier (GC), developed as a prognostic assay for metastasis after radical prostatectomy was investigated. Results: High quality genomic data was derived from 17 (100%) biopsies. Using the 212 ‘unbiased’ genes, the samples clustered by patient origin in unsupervised analysis. When only prostate cancer related genomic features were used, hierarchical clustering revealed samples clustered by needle-biopsy Gleason score (GS). Similarly, principal component analysis of the imaging features, found the primary source of variance segregated the samples into high (≥7) and low (6) GS. Pearson’s correlation analysis of genes with significant expression showed two main patterns of gene expression clustering prostate peripheral and transitional zone MRI features. Two-way hierarchical clustering of GC with radiomics features resulted in the expected groupings of high and low expressed genes in this metastasis signature. Conclusions: MP-MRI-targeted diagnostic biopsies can potentially improve risk stratification by directing pathological and genomic analysis to clinically significant index lesions. As determinant lesions are more reliably

  5. Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal staging in lung cancer*

    PubMed Central

    Fernández-Bussy, Sebastián; Labarca, Gonzalo; Canals, Sofia; Caviedes, Iván; Folch, Erik; Majid, Adnan

    2015-01-01

    OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic test with a high diagnostic yield for suspicious central pulmonary lesions and for mediastinal lymph node staging. The main objective of this study was to describe the diagnostic yield of EBUS-TBNA for mediastinal lymph node staging in patients with suspected lung cancer. METHODS: Prospective study of patients undergoing EBUS-TBNA for diagnosis. Patients ≥ 18 years of age were recruited between July of 2010 and August of 2013. We recorded demographic variables, radiological characteristics provided by axial CT of the chest, location of the lesion in the mediastinum as per the International Association for the Study of Lung Cancer classification, and definitive diagnostic result (EBUS with a diagnostic biopsy or a definitive diagnostic method). RESULTS: Our analysis included 354 biopsies, from 145 patients. Of those 145 patients, 54.48% were male. The mean age was 63.75 years. The mean lymph node size was 15.03 mm, and 90 lymph nodes were smaller than 10.0 mm. The EBUS-TBNA method showed a sensitivity of 91.17%, a specificity of 100.0%, and a negative predictive value of 92.9%. The most common histological diagnosis was adenocarcinoma. CONCLUSIONS: EBUS-TBNA is a diagnostic tool that yields satisfactory results in the staging of neoplastic mediastinal lesions. PMID:26176519

  6. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    PubMed Central

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment. PMID:28900553

  7. Magnetic resonance imaging-guided core needle breast biopsies resulting in high-risk histopathologic findings: upstage frequency and lesion characteristics.

    PubMed

    Weinfurtner, R Jared; Patel, Bhavika; Laronga, Christine; Lee, Marie C; Falcon, Shannon L; Mooney, Blaise P; Yue, Binglin; Drukteinis, Jennifer S

    2015-06-01

    Analysis of magnetic resonance imaging-guided breast biopsies yielding high-risk histopathologic features at a single institution found an overall upstage rate to malignancy of 14% at surgical excision. All upstaged lesions were associated with atypical ductal hyperplasia. Flat epithelial atypia and atypical lobular hyperplasia alone or with lobular carcinoma in situ were not associated with an upstage to malignancy. The purpose of the present study w as to determine the malignancy upstage rates and imaging features of high-risk histopathologic findings resulting from magnetic resonance imaging (MRI)-guided core needle breast biopsies. These features include atypical ductal hyperplasia (ADH), atypical lobular hyperplasia (ALH), flat epithelial atypia (FEA), and lobular carcinoma in situ (LCIS). A retrospective medical record review was performed on all MRI-guided core needle breast biopsies at a single institution from June 1, 2007 to December 1, 2013 to select biopsies yielding high-risk histopathologic findings. The patient demographics, MRI lesion characteristics, and histopathologic features at biopsy and surgical excision were analyzed. A total of 257 MRI-guided biopsies had been performed, and 50 yielded high-risk histopathologic features (19%). Biopsy site and surgical excision site correlation was confirmed in 29 of 50 cases. Four of 29 lesions (14%) were upstaged: 1 case to invasive ductal carcinoma and 3 cases to ductal carcinoma in situ. ADH alone had an overall upstage rate of 7% (1 of 14), mixed ADH/ALH a rate of 75% (3 of 4), ALH alone or with LCIS a rate of 0% (0 of 7), and FEA a rate of 0% (0 of 4). Only mixed ADH/ALH had a statistically significant upstage rate to malignancy compared with the other high-risk histopathologic subtypes combined. No specific imaging characteristics on MRI were associated with an upstage to malignancy on the statistical analysis. MRI-guided breast biopsies yielding high-risk histopathologic features were associated with

  8. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  9. Primary esophageal mucosa-associated lymphoid tissue lymphoma diagnosed by using stacked forceps biopsy.

    PubMed

    Lee, D S; Ahn, Y C; Eom, D W; Lee, S J

    2016-10-01

    Non-Hodgkin lymphoma involving the esophagus is very rare. Only a few cases have been reported in the English literature to date, and it accounts for less than 1% of all cases of gastrointestinal lymphoma. As this malignancy manifests as a submucosal tumor, pathological diagnosis by using a simple endoscopic biopsy alone is difficult. Therefore, surgical biopsy, endoscopic mucosal resection, and endoscopic ultrasound-guided fine-needle aspiration have been used in most cases. Herein, we report a case of esophageal mucosa-associated lymphoid tissue lymphoma in a 49-year-old man, which involved the use of a stacked forceps biopsy to obtain adequate samples for pathological analysis; the use of the stacked forceps biopsy method is unlike those used in previous cases. The patient received cyclophosphamide, vincristine, and prednisolone chemotherapy; he achieved a complete response. In addition, we review the literature relevant to this case. © 2015 International Society for Diseases of the Esophagus.

  10. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Osteoid Osteoma: A Case Series Report.

    PubMed

    Rovella, Marcello S; Martins, Guilherme L P; Cavalcanti, Conrado F A; Bor-Seng-Shu, Edson; Camargo, Olavo P; Cerri, Giovanni G; Menezes, Marcos R

    2016-04-01

    Osteoid osteoma is painful benign tumor. The aim of this study was to report our initial experience using magnetic resonance-guided focused ultrasound to treat osteoid osteomas. This retrospective single-center study included four patients treated with magnetic resonance-guided focused ultrasound. They presented with severe pain with reduced quality of life and a poor response to clinical treatment. The pre- and post-treatment evaluation comprised computed tomography and magnetic resonance imaging and focused on quality of life and the impact of pain on daily activities. After treatment, three patients had complete pain resolution with no recurrence. One patient had a recurrence of symptoms after 2 wk and underwent a new successful treatment with increased energy levels. On average, 13 sonications were administered (8-18 sonications/treatment) with an average energy of 2,003 J (range: 1,063-3,522 J). Magnetic resonance-guided focused ultrasound appears to be a feasible, tolerable and effective treatment in selected patients with osteoid osteomas. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Safety of ultrasound-guided high-intensity focused ultrasound ablation for diffuse adenomyosis: A retrospective cohort study.

    PubMed

    Feng, Yujie; Hu, Liang; Chen, Wenzhi; Zhang, Rong; Wang, Xi; Chen, Jinyun

    2017-05-01

    To evaluate the safety of ultrasound-guided high-intensity focused ultrasound (HIFU) ablation for patients with diffuse adenomyosis. This was a retrospective cohort study. The data was collected from 417 symptomatic adenomyosis patients who underwent ultrasound-guided HIFU between January 2012 and December 2015 at 1st Affiliated Hospital of Chongqing Medical University, Chongqing, China. Among them were 260 patients with diffuse adenomyosis (Group D) and 157 patients with focal adenomyosis (Group F). All patients underwent contrast-enhanced magnetic resonance imaging (MRI) one week before and the day after HIFU treatment. Successful treatment with HIFU was measured by the non-perfused volume ratio (NPVR). Intraprocedural and postprocedural adverse effects and complications were recorded to assess the safety of the procedure. Patients were followed-up for three months post-treatment. Complications were given a grade A through F according to the SIR Standards. All patients successfully completed the procedure, non-perfused regions appeared in 415 (99.5%) patients. The non-perfused volume ratio (NPVR) of Group D was significantly lower than that of Group F (P<0.05). During the procedure, the odds ratio of skin-burning pain was 1.7 (OR=1.617, 95% CI: 1.103-2.532), when comparing Group D with Group F, while the odds ratio of inguinal pain was equal to 2.0 (OR=2.038, 95% CI: 1.161-3.580), when Group F was compared to Group D. 97 patients (23.3%) received nominal therapy due to complications ([Society of interventional radiology, SIR]-B grade), among them, there were 62 cases (23.8%) in Group D and 35 cases (22.3%) in Group F. No significant difference was found between the two groups (P>0.05) and neither of the reported complications of SIR-C-SIR-F occurred within the two groups. Based on our results, ultrasound-guided HIFU is safe for the treatment of diffuse adenomyosis, and controlling the ablation zone is crucial to ensure patients' safety. Copyright © 2016 Elsevier

  12. Basics of kidney biopsy: A nephrologist's perspective

    PubMed Central

    Agarwal, S. K.; Sethi, S.; Dinda, A. K.

    2013-01-01

    The introduction of the kidney biopsy is one of the major events in the history of nephrology. Primary indications of kidney biopsy are glomerular hematuria/proteinuria with or without renal dysfunction and unexplained renal failure. Kidney biopsy is usually performed in prone position but in certain situations, supine and lateral positions may be required. Biopsy needles have changed with times from Vim–Silverman needle to Tru-cut needle to spring-loaded automatic gun. The procedure has also changed from blind bedside kidney biopsy to ultrasound marking to real-time ultrasound guidance to rarely computerized tomography guidance and laparoscopic and open biopsy. In very specific situations, transjugular kidney biopsy may be required. Most of the centers do kidney biopsy on short 1-day admission, whereas some take it as an outdoor procedure. For critical interpretation of kidney biopsy, adequate sample and clinical information are mandatory. Tissue needs to be stained with multiple stains for delineation of various components of kidney tissue. Many consider that electron microscopy (EM) is a must for all kidney biopsies, but facilities for EM are limited even in big centers. Sophisticated tests such as immunohistochemistry and in-situ hybridization are useful adjuncts for definitive diagnosis in certain situations. PMID:23960337

  13. A novel ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  14. Ultrasound-guided injection for plantar fasciitis: A brief review

    PubMed Central

    Nair, AS; Sahoo, RK

    2016-01-01

    Plantar fasciitis (PF) is a distressing condition experienced by many patients. Although self-limiting, it tends to become a chronic ailment if the precipitating factors are not addressed. One of the modality of treating PF is intra-lesional corticosteroid injection. This was done using palpation technique earlier but nowadays many specialists use ultrasound (US) imaging as a guide to give injection accurately instead of inadvertently damaging the plantar fascia or injecting into surrounding soft tissue, both of which can have serious implications. We did a literature search in Medline, Scopus, and Embase databases to find out articles describing US-guided corticosteroid injection for treating PF and whether guided injection was effective than injection given by palpation. PMID:27833490

  15. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algin, Oktay, E-mail: droktayalgin@gmail.com; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-02-15

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improvedmore » clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.« less

  16. Hematoma formation during breast core needle biopsy in women taking antithrombotic therapy.

    PubMed

    Chetlen, Alison L; Kasales, Claudia; Mack, Julie; Schetter, Susann; Zhu, Junjia

    2013-07-01

    The purpose of this study was to compare hematoma formation after breast core needle biopsy performed on patients undergoing and those not undergoing concurrent antithrombotic therapy. A prospective assessment of core needle biopsies (stereotactic, ultrasound guided, or MRI guided) performed on patients enrolled between September 2011 and July 2012 formed the basis of this study. Postprocedure mediolateral and craniocaudal mammograms were evaluated for the presence and size of hematomas. Patients were clinically evaluated for complications 24-48 hours after the procedure through telephone call or face-to-face consultation. Needle size, type of biopsy, and presence of hematoma and documented complications were correlated with use of antithrombotic agents (including aspirin, warfarin, clopidogrel, and daily nonsteroidal antiinflammatory medications). No clinically significant hematomas or bleeding complications were found. Eighty-nine of 617 (14.4%) non-clinically significant hematomas were detected on postprocedure mammograms. The probability of development of a non-clinically significant hematoma was 21.6% for patients taking antithrombotics and 13.0% for those not taking antithrombotics. Concurrent antithrombotic therapy and larger needle gauge were significant factors contributing to the probability of hematoma formation. The volume of the hematoma was not related to needle gauge or presence of antithrombotic therapy. No clinically significant hematomas were found. Because there are potential life-threatening risks to stopping antithrombotic therapy before breast biopsy, withholding antithrombotic therapy for core needle breast biopsy is not recommended because the incidence of non-clinically significant hematoma is low.

  17. Biopsy system guided by positron emission tomography in real-time

    NASA Astrophysics Data System (ADS)

    Moliner, L.; Álamo, J.; Hellingman, D.; Peris, J. L.; Gomez, J.; Tattersall, P.; Carrilero, V.; Orero, A.; Correcher, C.; Benlloch, J. M.

    2016-03-01

    In this work we present the MAMMOCARE prototype, a biopsy guided system based on PET. The system is composed by an examination table where the patient is situated in prone position, a PET detector and a biopsy device. The PET detector is composed by two rings. These rings can be separated mechanically in order to allow the needle insertion. The first acquisition is performed with the closed ring configuration in order to obtain a high quality image to locate the lesion. Then, the software calculates the optimum path for the biopsy and moves the biopsy and PET systems to the desired position. At this point, two compression pallets are used to hold the breast. Then, the PET system opens and the biopsy procedure starts. The images are obtained at several steps to ensure the correct location of the needle during the procedure. The performance of the system is evaluated measuring the spatial resolution and sensitivity according the NEMA standard. The uniformity of the reconstructed images is also estimated. The radial resolution is 1.62mm in the center of the FOV and 3.45mm at 50mm off the center in the radial direction using the closed configuration. In the open configuration the resolution reaches 1.85mm at center and 3.65mm at 50mm. The sensitivity using an energy window of 250keV-750keV is 3.6% for the closed configuration and 2.5% for the open configuration. The uniformity measured in the center of the FOV is 14% and 18% for the closed and open configurations respectively.

  18. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    PubMed

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  19. An ultrasound-guided fluorescence tomography system: design and specification

    NASA Astrophysics Data System (ADS)

    D'Souza, Alisha V.; Flynn, Brendan P.; Kanick, Stephen C.; Torosean, Sason; Davis, Scott C.; Maytin, Edward V.; Hasan, Tayyaba; Pogue, Brian W.

    2013-03-01

    An ultrasound-guided fluorescence molecular tomography system is under development for in vivo quantification of Protoporphyrin IX (PpIX) during Aminolevulinic Acid - Photodynamic Therapy (ALA-PDT) of Basal Cell Carcinoma. The system is designed to combine fiber-based spectral sampling of PPIX fluorescence emission with co-registered ultrasound images to quantify local fluorophore concentration. A single white light source is used to provide an estimate of the bulk optical properties of tissue. Optical data is obtained by sequential illumination of a 633nm laser source at 4 linear locations with parallel detection at 5 locations interspersed between the sources. Tissue regions from segmented ultrasound images, optical boundary data, white light-informed optical properties and diffusion theory are used to estimate the fluorophore concentration in these regions. Our system and methods allow interrogation of both superficial and deep tissue locations up to PpIX concentrations of 0.025ug/ml.

  20. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial)

    PubMed Central

    2011-01-01

    Background Breast-conserving surgery for breast cancer was developed as a method to preserve healthy breast tissue, thereby improving cosmetic outcomes. Thus far, the primary aim of breast-conserving surgery has been the achievement of tumour-free resection margins and prevention of local recurrence, whereas the cosmetic outcome has been considered less important. Large studies have reported poor cosmetic outcomes in 20-40% of patients after breast-conserving surgery, with the volume of the resected breast tissue being the major determinant. There is clear evidence for the efficacy of ultrasonography in the resection of nonpalpable tumours. Surgical resection of palpable breast cancer is performed with guidance by intra-operative palpation. These palpation-guided excisions often result in an unnecessarily wide resection of adjacent healthy breast tissue, while the rate of tumour-involved resection margins is still high. It is hypothesised that the use of intra-operative ultrasonography in the excision of palpable breast cancer will improve the ability to spare healthy breast tissue while maintaining or even improving the oncological margin status. The aim of this study is to compare ultrasound-guided surgery for palpable tumours with the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumour-free margins, cosmetic outcomes and quality of life. Methods/design In this prospective multicentre randomised controlled clinical trial, 120 women who have been diagnosed with palpable early-stage (T1-2N0-1) primary invasive breast cancer and deemed suitable for breast-conserving surgery will be randomised between ultrasound-guided surgery and palpation-guided surgery. With this sample size, an expected 20% reduction of resected breast tissue and an 18% difference in tumour-free margins can be detected with a power of 80%. Secondary endpoints include cosmetic outcomes and quality of life. The rationale, study

  1. Magnetic resonance guided high-intensity focused ultrasound ablation of musculoskeletal tumors

    PubMed Central

    Avedian, Raffi S.; Gold, Garry; Ghanouni, Pejman; Pauly, Kim Butts

    2015-01-01

    This article reviews the fundamental principles and clinical experimental uses of magnetic resonance guided high-intensity focused ultrasound (MRgHIFU) ablation of musculoskeletal tumors. MRgHIFU is a noninvasive treatment modality that takes advantage of the ability of magnetic resonance to measure tissue temperature and uses this technology to guide high-intensity focused ultrasound waves to a specific focus within the human body that results in heat generation and complete thermal necrosis of the targeted tissue. Adjacent normal tissues are spared because of the accurate delivery of thermal energy, as well as, local blood perfusion that provides a cooling effect. MRgHIFU is approved by the Food and Drug Administration for the treatment of uterine fibroids and is used on an experimental basis to treat breast, prostate, liver, bone, and brain tumors. PMID:26120376

  2. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated

  3. Combined Ultrasound and MR Imaging to Guide Focused Ultrasound Therapies in the Brain

    PubMed Central

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-01-01

    Purpose Several emerging therapies with potential for use in the brain harness effects produced by acoustic cavitation – the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength, and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. Materials and Methods We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. Results The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. Conclusion While preliminary, these data clearly demonstrate, for the first time, that is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate it will also prove to

  4. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    NASA Astrophysics Data System (ADS)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  5. Novel ultrasound-responsive chitosan/perfluorohexane nanodroplets for image-guided smart delivery of an anticancer agent: Curcumin.

    PubMed

    Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid

    2017-05-01

    Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. A review of randomised controlled trials comparing ultrasound-guided foam sclerotherapy with endothermal ablation for the treatment of great saphenous varicose veins.

    PubMed

    Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W

    2016-05-01

    The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author

  7. A technical report on ultrasound-guided scapulocostal syndrome injection.

    PubMed

    McCarthy, C; Harmon, D

    2016-08-01

    We describe a case report and technique for using an ultrasound scanner and a linear transducer to guide serratus posterior superior (SPS) muscle injection. A 43-year-old female presented with chronic pain centered under the right upper portion of her scapula impacting her activities of daily living. For the ultrasound-guided SPS muscle injection, the patient was placed in the prone position. The transducer was oriented in a transverse orientation at the level of the C6-T1 vertebrae. Here the SPS muscle attaches to the lower portion of the ligament nuchae and the intervening interspinous ligaments. The muscle fibers run inferiorly and laterally to attach to the 2nd-5th ribs which were identified along with the lateral portion of the serratus posterior superior muscle which is covered by the scapula. Real-time imaging was used to direct a spinal needle into the trigger points of the SPS muscle, where solution was injected under direct vision. The patient's pain symptoms improved significantly. Serratus posterior superior injection can confirm a diagnosis of scapulocostal syndrome and be therapeutically beneficial.

  8. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    PubMed

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7 < 2.6, 1.6 < 4.0, 3.5 < 5.8, 3.6 < 5.2, 3.2 < 4.2, 1.3 < 2.0), and a higher patient satisfaction score at 6, 12, 18, 24, and 36 h post-operatively than group 2 (7.8 > 6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p < 0.001), and the mean size of rebound pain was smaller in group 1 than that in group 2 (2.5 > 4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier

  9. CT-guided fine-needle biopsy of focal lung lesions as the method for reducing the number of invasive diagnostic procedures

    PubMed Central

    Chodorowska, Anna; Rzechonek, Adam; Dyła, Tomasz; Muszczyńska-Bernhard, Beata; Adamek, Jarosław

    2010-01-01

    Summary Background: CT-guided fine-needle biopsy (FNB) of focal lung lesions is one of the possibilities of obtaining histopathological diagnosis in pulmonary diseases. Its place in the algorithm is determined by the invasiveness. In case of no diagnosis after bronchoscopy or endobronchial ultrasonography (EBUS) guided biopsy, CT-guided FNB can become an alternative for more invasive procedures, such as open lung biopsy – thoracotomy. Material/Methods: Since January 2009 until February 2010, we performed 37 CT-guided FNB in 34 patients aged 31 to 76 (mean age 60.9). Among them, there were 16 women and 18 men. All patients underwent a standard chest CT with contrast medium injection. They were diagnosed with focal lesions and they were rejected from surgery as the primary method of treatment. During biopsy, the patient was positioned prone or supine, depending on the location of lesions. After performing a scout image and initial slices, we marked the level of biopsy, using a metal marker. Next, the biopsy needle was introduced under local anesthesia. When the obtained position of the needle in the lesion was correct, the specimen was taken. After needle removal, the patient was controlled for the presence of complications (i.e. pneumothorax). Biopsy time ranged from 10 to 50 minutes. Results: In 94.6% of biopsies, the specimens for histopathological and cytological examinations were obtained. In 22 (64.7%) patients, histopathological diagnoses (in 14 cases this was the non-small cell cancer and in 8, inflammatory lesions) were established which allowed us to resign from invasive thoracotomy and to introduce an appropriate treatment. In the remaining 12 patients, no diagnosis was established. Complications in the form of a minor pneumothorax occurred in 2 patients. Conclusions: Fine-needle biopsy of the focal lung lesions is an affective and a relatively safe method, which can replace the more invasive diagnostic thoracotomy in the majority of patients. PMID

  10. Sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region

    PubMed Central

    Karmakar, M K; Li, X; Kwok, W H; Ho, A M-H; Ngan Kee, W D

    2012-01-01

    Objectives The use of ultrasound to guide peripheral nerve blocks is now a well-established technique in regional anaesthesia. However, despite reports of ultrasound guided epidural access via the paramedian approach, there are limited data on the use of ultrasound for central neuraxial blocks, which may be due to a poor understanding of spinal sonoanatomy. The aim of this study was to define the sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach. Methods The sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach was defined using a “water-based spine phantom”, young volunteers and anatomical slices rendered from the Visible Human Project data set. Results The water-based spine phantom was a simple model to study the sonoanatomy of the osseous elements of the lumbar spine. Each osseous element of the lumbar spine, in the spine phantom, produced a “signature pattern” on the paramedian sagittal scans, which was comparable to its sonographic appearance in vivo. In the volunteers, despite the narrow acoustic window, the ultrasound visibility of the neuraxial structures at the L3/L4 and L4/L5 lumbar intervertebral spaces was good, and we were able to delineate the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach. Conclusion Using a simple water-based spine phantom, volunteer scans and anatomical slices from the Visible Human Project (cadaver) we have described the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region. PMID:22010025

  11. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  12. Sonothrombolysis of Intra-Catheter Aged Venous Thrombi Using Microbubble Enhancement and Guided Three Dimensional Ultrasound Pulses

    PubMed Central

    Kutty, Shelby; Xie, Feng; Gao, Shunji; Drvol, Lucas K; Lof, John; Fletcher, Scott E; Radio, Stanley J; Danford, David A; Hammel, James M; Porter, Thomas R

    2010-01-01

    Central venous and arterial catheters are a major source of thrombo-embolic disease in children. We hypothesized that guided high mechanical index (MI) impulses from diagnostic three-dimensional (3D) ultrasound during an intravenous microbubble infusion could dissolve these thrombi. An in vitro system simulating intra-catheter thrombi was created and then treated with guided high MI impulses from 3D ultrasound, utilizing low MI microbubble sensitive imaging pulse sequence schemes to detect the microbubbles (Perflutren Lipid Microsphere, Definity®, Lantheus). Ten aged thrombi over 24 hours old were tested using 3D ultrasound coupled with a continuous diluted microbubble infusion (Group A), and ten with 3D ultrasound alone (Group B). Mean thrombus age was 28.6 hours (range 26.6–30.3). Groups A exhibited a 55 ± 19 % reduction in venous thrombus size, compared to 31±10 % for Group B (p=0.008). Feasibility testing was performed in 4 pigs, establishing a model to further investigate the efficacy. Sonothrombolysis of aged intra-catheter venous thrombi can be achieved with commercially available microbubbles and guided high MI ultrasound from a diagnostic 3D transducer. PMID:20696549

  13. Endoscopic trans-nasal approach for biopsy of orbital tumours using image-guided neuro-navigation system.

    PubMed

    Sieskiewicz, A; Lyson, T; Mariak, Z; Rogowski, M

    2008-05-01

    Histopathological diagnosis of intraorbital tumours is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumours. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumours and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumours and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue.

  14. Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): results of a European consensus meeting.

    PubMed

    Heywang-Köbrunner, Sylvia H; Sinnatamby, Ruchi; Lebeau, Annette; Lebrecht, Antje; Britton, Peter D; Schreer, Ingrid

    2009-11-01

    Quality assurance of MR-guided vacuum-assisted breast biopsy (VAB). A consensus was achieved based on the existing literature and experience of an interdisciplinary group comprising European specialists in breast imaging and VAB. Full imaging work-up must be completed according to existing standards before an indication for MR-guided VAB is established. The procedure should be reserved for lesions demonstrable by MRI alone. Acquisition of >24 cores (11-Gauge) should be routinely attempted, with the intention of sufficiently removing small lesions for accurate diagnosis. Following biopsy the patient should be re-imaged to demonstrate the biopsy site and its proximity to the lesion and hence the likely accuracy of the sampling. All patients should be discussed in a regular interdisciplinary conference and a documented consensus reached regarding patient management. Regular audit and review of all MR-guided VAB results and subsequent follow-up are recommended. This consensus includes protocols for the indication, performance parameters, interdisciplinary interpretation therapeutic recommendation, documentation and follow-up of MR-guided VAB. It does not replace official recommendations for percutaneous biopsy.

  15. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    PubMed

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  16. Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy.

    PubMed

    Graffy, Peter; Loomis, Scott B; Pickhardt, Perry J; Lubner, Meghan G; Kitchin, Douglas R; Lee, Fred T; Hinshaw, J Louis

    2017-04-01

    To investigate whether an autologous intraparenchymal blood patch (IPB) reduces the rate of pneumothorax-related complications associated with computed tomography (CT)-guided lung biopsies. This study included 834 patients: 482 who received an IPB and 352 who did not. Retrospective review was performed of all CT-guided lung biopsies performed at a single institution between August 2006 and September 2013. Patients were excluded if no aerated lung was crossed. The rate of pneumothorax, any associated intervention (eg, catheter placement, aspiration), chest tube placement, and chest tube replacement requiring hospital admission were compared by linear and multiple regression analysis. Patients who received an IPB had a significantly lower rate of pneumothorax (145 of 482 [30%] vs 154 of 352 [44%]; P < .0001), pneumothorax-related intervention (eg, catheter aspiration, pleural blood patch, chest tube placement; 43 of 482 [8.9%] vs 85 of 352 [24.1%]; P < .0001), and chest tube placement along with other determinants requiring hospital admission (18 of 482 [3.7%] vs 27 of 352 [7.7%]; P < .0001). No complications related to the IPB were noted in the study group. Autologous IPB placement is associated with a decreased rate of pneumothorax and associated interventions, including chest tube placement and hospital admission, after CT-guided lung biopsies, with no evidence of any adverse effects. These results suggest that an IPB is safe and effective and should be considered when aerated lung is traversed while performing a CT-guided lung biopsy. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  17. CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.

  18. Evolving biopsy techniques for the diagnosis of neuroblastoma in children.

    PubMed

    Campagna, Giovanni; Rosenfeld, Eric; Foster, Jennifer; Vasudevan, Sanjeev; Nuchtern, Jed; Kim, Eugene; Commander, Sarah; Naik-Mathuria, Bindi

    2018-04-14

    To compare the adequacy and safety of percutaneous core needle biopsy and surgical wedge biopsy of neuroblastoma in children. A retrospective review of patients who underwent biopsy for intermediate- or high-risk neuroblastoma at our institution between 2011 and 2015 was performed (recent cohort). Procedure details and outcomes were collected and analyzed using descriptive statistics and Wilcoxon rank tests; P < 0.05 was considered significant. Published data from 2002 to 2010 were compared (historic cohort). Since 2011, percutaneous, ultrasound-guided, core needle biopsy has been more commonly utilized (47% (16/34) recent vs. 25% (7/28) historic; P = 0.07), and the number of core needle samples increased from median 7 (historic) to 25 (recent). Complications decreased (21% (7/34) recent vs. 64% (18/28) historic; P < 0.01). Biopsy adequacy in the recent cohort was similar (94% percutaneous vs. 89% surgical; P = 1.00), which is improved from the historic cohort (71% percutaneous vs. 100% surgical; P = 0.06). Larger tumors were more likely to have a percutaneous biopsy (82 ± 37 cm percutaneous vs. 47 ± 29 cm surgical; P = 0.04). When multiple cores are obtained, percutaneous core needle biopsy is adequate for complete tissue diagnosis of neuroblastoma and can be safely performed. This can be considered as an alternative to open surgical biopsy. Treatment Study. III. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Prebiopsy Multiparametric Magnetic Resonance Imaging for Prostate Cancer Diagnosis in Biopsy-naive Men with Suspected Prostate Cancer Based on Elevated Prostate-specific Antigen Values: Results from a Randomized Prospective Blinded Controlled Trial.

    PubMed

    Tonttila, Panu P; Lantto, Juha; Pääkkö, Eija; Piippo, Ulla; Kauppila, Saila; Lammentausta, Eveliina; Ohtonen, Pasi; Vaarala, Markku H

    2016-03-01

    Multiparametric magnetic resonance imaging (MP-MRI) may improve the detection of clinically significant prostate cancer (PCa). To compare MP-MRI transrectal ultrasound (TRUS)-fusion targeted biopsy with routine TRUS-guided random biopsy for overall and clinically significant PCa detection among patients with suspected PCa based on prostate-specific antigen (PSA) values. This institutional review board-approved, single-center, prospective, randomized controlled trial (April 2011 to December 2014) included 130 biopsy-naive patients referred for prostate biopsy based on PSA values (PSA <20 ng/ml or free-to-total PSA ratio ≤0.15 and PSA <10 ng/ml). Patients were randomized 1:1 to the MP-MRI or control group. Patients in the MP-MRI group underwent prebiopsy MP-MRI followed by 10- to 12-core TRUS-guided random biopsy and cognitive MRI/TRUS fusion targeted biopsy. The control group underwent TRUS-guided random biopsy alone. MP-MRI 3-T phased-array surface coil. The primary outcome was the number of patients with biopsy-proven PCa in the MP-MRI and control groups. Secondary outcome measures included the number of positive prostate biopsies and the proportion of clinically significant PCa in the MP-MRI and control groups. Between-group analyses were performed. Overall, 53 and 60 patients were evaluable in the MP-MRI and control groups, respectively. The overall PCa detection rate and the clinically significant cancer detection rate were similar between the MP-MRI and control groups, respectively (64% [34 of 53] vs 57% [34 of 60]; 7.5% difference [95% confidence interval (CI), -10 to 25], p=0.5, and 55% [29 of 53] vs 45% [27 of 60]; 9.7% difference [95% CI, -8.5 to 27], p=0.8). The PCa detection rate was higher than assumed during the planning of this single-center trial. MP-MRI/TRUS-fusion targeted biopsy did not improve PCa detection rate compared with TRUS-guided biopsy alone in patients with suspected PCa based on PSA values. In this randomized clinical trial

  20. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with

  1. Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity

    PubMed Central

    Sconfienza, L.M.; Perrone, N.; Lacelli, F.; Lentino, C.; Serafini, G.

    2008-01-01

    Purpose Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. Method and materials The ultrasound-guided technique for BTX-A injection was used on 10 patients. The needle was inserted into the muscle belly at an angle of 45° along the longitudinal axis of the muscle when allowed by patient's condition. Results In all cases, the iliopsoas muscle was easily identified and both the iliac and psoas components were assessed. Introduction of the needle and drug injection were entirely carried out under ultrasonographic guidance. The procedure was successful in all patients, even in those with a high-grade spasticity, and general anesthesia was not required. Conclusions This ultrasound-guided technique allows accurate guidance for the injection of BTX-A, and it can be considered as an alternate supportive therapy in patients with spasticity and dystonia. PMID:23396653

  2. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivera-Sanfeliz, Gerant, E-mail: gerantrivera@ucsd.edu; Kinney, Thomas B.; Rose, Steven C.

    2005-06-15

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to homemore » after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted.« less

  3. Propogation loss with frequency of ultrasound guided waves in a composite metal-honeycomb structure

    NASA Astrophysics Data System (ADS)

    Saxena, Indu F.; Baid, Harsh K.; Guzman, Narciso; Kempen, Lothar U.; Mal, Ajit

    2009-05-01

    Non-destructive testing of critical structural components is time consuming, while necessary for maintaining safe operation. Large aerospace structures, such as the vertical stabilizers of aircraft undergo inspection at regular intervals for damage diagnostics. However, conventional techniques for damage detection and identification before repair can be scheduled are conducted off-line and therefore can take weeks. The use of guided ultrasound waves is being investigated to expedite damage detection in composites. We measure the frequency dependent loss of ultrasonic guided waves for a structure comprising a boron-nitride composite skin sandwiching an aluminum honeycomb. A wide range of ultrasound frequencies propagate as measured using PZTs, with the lowest attenuation observed about 200-250 kHz. These measurements are confirmed using optical fiber Bragg grating arrays used as ultrasound transducers.

  4. Feasibility of ultrasound-guided epidural access at the lumbo-sacral space in dogs.

    PubMed

    Liotta, Annalisa; Busoni, Valeria; Carrozzo, Maria Valentina; Sandersen, Charlotte; Gabriel, Annick; Bolen, Géraldine

    2015-01-01

    Epidural injections are commonly performed blindly in veterinary medicine. The aims of this study were to describe the lumbosacral ultrasonographic anatomy and to assess the feasibility of an ultrasound-guided epidural injection technique in dogs. A cross sectional anatomic atlas of the lumbosacral region and ex vivo ultrasound images were obtained in two cadavers to describe the ultrasound anatomy and to identify the landmarks. Sixteen normal weight canine cadavers were used to establish two variations of the technique for direct ultrasound-guided injection, using spinal needles or epidural catheters. The technique was finally performed in two normal weight cadavers, in two overweight cadavers and in five live dogs with radiographic abnormalities resulting of the lumbosacral spine. Contrast medium was injected and CT was used to assess the success of the injection. The anatomic landmarks to carry out the procedure were the seventh lumbar vertebra, the iliac wings, and the first sacral vertebra. The target for directing the needle was the trapezoid-shaped echogenic zone between the contiguous articular facets of the lumbosacral vertebral canal visualized in a parasagittal plane. The spinal needle or epidural catheter was inserted in a 45° craniodorsal-caudoventral direction through the subcutaneous tissue and the interarcuate ligament until reaching the epidural space. CT examination confirmed the presence of contrast medium in the epidural space in 25/25 dogs, although a variable contamination of the subarachnoid space was also noted. Findings indicated that this ultrasound-guided epidural injection technique is feasible for normal weight and overweight dogs, with and without radiographic abnormalities of the spine. © 2014 American College of Veterinary Radiology.

  5. MR-guided focused ultrasound robot for performing experiments on large animals

    NASA Astrophysics Data System (ADS)

    Mylonas, N.; Damianou, C.

    2011-09-01

    Introduction: In this paper an experimental MRI-guided focused ultrasound robot for large animals is presented. Materials and methods: A single element spherically focused transducer of 4 cm diameter, focusing at 10 cm and operating at 1 MHz was used. A positioning device was developed in order to scan the ultrasound transducer for performing MR-guided focused ultrasound experiments in large animals such as pig, sheep and dog. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, Acrylonitrile Butadiene Styrene (ABS) plastic, brass screws, and brass pulleys. The system is manufactured automatically using a rapid prototyping system. Results: The system was tested successfully in a number of animals for various tasks (creation of single lesions, creation of overlapping lesions, and MR compatibility). Conclusions: A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can be via a lateral or superior-inferior approach. This system has the potential to be marketed as a cost effective solution for performing experiments in small and large animals.

  6. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning.

    PubMed

    Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A

    2014-08-01

    To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Ultrasound-guided percutaneous tracheostomy in critically ill obese patients

    PubMed Central

    2012-01-01

    Introduction The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Methods Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m2. The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). Results The median BMIs were 34 kg/m2 (32-38) in the obese patient group and 25 kg/m2 (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. Conclusions This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. Trial registration ClinicalTrials.gov: NCT01502657. PMID:22390815

  8. Ultrasound-guided percutaneous tracheostomy in critically ill obese patients.

    PubMed

    Guinot, Pierre-Grégoire; Zogheib, Elie; Petiot, Sandra; Marienne, Jean-Pierre; Guerin, Anne-Marie; Monet, Pauline; Zaatar, Rody; Dupont, Hervé

    2012-12-12

    The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m². The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). The median BMIs were 34 kg/m² (32-38) in the obese patient group and 25 kg/m² (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. ClinicalTrials.gov: NCT01502657.

  9. New platform for evaluating ultrasound-guided interventional technologies

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.

    2016-04-01

    Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.

  10. Diagnosis of metastatic pancreatic mesenchymal tumors by endoscopic ultrasound-guided fine-needle aspiration.

    PubMed

    Varghese, Linda; Ngae, Min Yi; Wilson, Andrew P; Crowder, Clinton D; Gulbahce, H Evin; Pambuccian, Stefan E

    2009-11-01

    Involvement of the pancreas by metastatic sarcoma is rare, and can prove challenging to differentiate from sarcomatoid carcinomas which occur more commonly. The endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) technique has been successfully used for the diagnosis of pancreatic carcinomas whether primary or metastatic, and is now considered the most effective noninvasive method for the identification of pancreatic metastases. However, to date very few reports detail the diagnosis of mesenchymal neoplasms by EUS-FNA. Herein, we report a series of four patients who underwent EUS-FNA of the pancreas, where the diagnosis of metastatic sarcoma was made based on morphology and ancillary studies. The cases include metastases of leiomyosarcoma, liposarcoma, alveolar rhabdomyosarcoma, and solitary fibrous tumor. The history of a primary sarcoma of the chest wall, mediastinum, and respectively lower extremity was known for the first three of these patients while in the case of the solitary fibrous tumor a remote history of a paraspinal "hemangiopericytoma" was only elicited after the EUS-FNA diagnosis was made. We conclude that EUS-FNA is efficient and accurate in providing a diagnosis of sarcoma, even in patients without a known primary sarcoma, thus allowing institution of therapy without additional biopsies.

  11. Outcomes of Ultrasound-Guided Thrombin Injection of Nongroin Arterial Pseudoaneurysms.

    PubMed

    Valesano, Johnathan C; Schmitz, John J; Kurup, A Nicholas; Schmit, Grant D; Moynagh, Michael R; Atwell, Thomas D; Lewis, Bradley D; Lee, Robert A; Callstrom, Matthew R

    2017-08-01

    To evaluate success and complication rates of percutaneous ultrasound-guided thrombin injection of nongroin pseudoaneurysms (PSAs). Retrospective review of a prospectively maintained institutional database yielded 39 cases of arterial PSAs occurring at nongroin sites that were treated with percutaneous ultrasound-guided thrombin injection between 2000 and 2016 (average patient age 69.2 y ± 14.0). Of PSAs, 74.4% (29/39) arose in the upper extremities, and 92.3% (36/39) were iatrogenic. The brachial artery was the most commonly affected vessel (51.3% [20/39]), and arterial access was the most common cause (56.4% [22/39]). Average overall PSA size was 2.4 cm (range, 0.5-7.2 cm); average amount of thrombin injected was 320 IU (range, 50-2,000 IU). Technical success was defined as absence of flow within the PSA immediately after thrombin injection. Treatment success was defined as sustained thrombosis on follow-up imaging obtained at 1-3 days after treatment. Technical and treatment success rates of thrombin injections were 100% (39/39) and 84.8% (28/33), respectively. Longer term follow-up imaging (average 71 d; range, 12-201 d) was available for 7 of the treatment successes with 100% (7/7) showing sustained thrombosis. Comparing treatment successes and failures, there was no significant difference in average PSA size (2.3 cm vs 2.0 cm, P = .51) or average amount of thrombin injected (360 IU vs 180 IU, P = .14). There were no complications. Ultrasound-guided thrombin injection is a safe, efficacious treatment option for PSAs arising in nongroin locations. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  12. Guiding tissue regeneration with ultrasound in vitro and in vivo

    NASA Astrophysics Data System (ADS)

    Dalecki, Diane; Comeau, Eric S.; Raeman, Carol H.; Child, Sally Z.; Hobbs, Laura; Hocking, Denise C.

    2015-05-01

    Developing new technologies that enable the repair or replacement of injured or diseased tissues is a major focus of regenerative medicine. This paper will discuss three ultrasound technologies under development in our laboratories to guide tissue regeneration both in vitro and in vivo. A critical obstacle in tissue engineering is the need for rapid and effective tissue vascularization strategies. To address this challenge, we are developing acoustic patterning techniques for microvascular tissue engineering. Acoustic radiation forces associated with ultrasound standing wave fields provide a rapid, non-invasive approach to spatially pattern cells in three dimensions without affecting cell viability. Acoustic patterning of endothelial cells leads to the rapid formation of microvascular networks throughout the volumes of three-dimensional hydrogels, and the morphology of the resultant microvessel networks can be controlled by design of the ultrasound field. A second technology under development uses ultrasound to noninvasively control the microstructure of collagen fibers within engineered tissues. The microstructure of extracellular matrix proteins provides signals that direct cell functions critical to tissue regeneration. Thus, controlling collagen microfiber structure with ultrasound provides a noninvasive approach to regulate the mechanical properties of biomaterials and control cellular responses. The third technology employs therapeutic ultrasound to enhance the healing of chronic wounds. Recent studies demonstrate increased granulation tissue thickness and collagen deposition in murine dermal wounds exposed to pulsed ultrasound. In summary, ultrasound technologies offer noninvasive approaches to control cell behaviors and extracellular matrix organization and thus hold great promise to advance tissue regeneration in vitro and in vivo.

  13. A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.

    PubMed

    Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M

    To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18 F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.

    PubMed

    Ajmal, Muhammad; Power, Susan; Smith, Tim; Shorten, George D

    2011-02-01

    To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting. Pilot prospective observational study. Orthopedic operating room of a regional trauma hospital. 15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire. The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion. Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  16. Prophylactic antibiotics reduce sepsis after biopsy of the prostate.

    PubMed

    Hayatzaki, Khalilullah; Menne, Sveinar; Nielsen, Karsten

    2014-11-01

    Prostate cancer is the most common form of cancer in Danish men, and the incidence is rising. The diag-nosis is made by transrectal prostate biopsy guided by ultrasound. This procedure has several complications, the most severe being sepsis. In our department, this is sought prevented by administering the prophylactic antibiotics metronidazol and ciprofloxacin. This study examined the rate of sepsis in patients who had the procedure performed at our department. The electronic patient records of all patients who had transrectal ultrasound of the prostate with biopsies performed at the Department of Urology at Naestved Hospital in the period from 1 May 2009 to 31 May 2011 were examined, and all admissions to our department (or any department in the same region) due to sepsis within two weeks of the procedure were registered. A total of 438 patients had the procedure performed, some multiple times, which resulted in a total of 511 procedures. In all, four patients were later admitted due to sepsis, corresponding to 0.91%. Three of the patients had positive blood and urine cultures in which Escherichia coli resistant to ciprofloxacin were found, the last had been prescribed antibiotics by a general practitioner the previous day, and no bacteria could be cultured. The frequency of sepsis after transrectal needle biopsies from the prostate at our department was found to be below 1% in this study, which is comparable to international findings. Most of the cases of sepsis were related to ciprofloxacin-resistant bacteria. Further randomised studies are needed to investigate the ideal prophylactic regime. not relevant. not relevant.

  17. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    NASA Astrophysics Data System (ADS)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  18. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukuda, Hozumi, E-mail: fkdhzmrad@mitsuihosp.or.jp; Ibukuro, Kenji; Tsukiyama, Toshitaka

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which weremore » therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis.« less

  19. Comparison of ultrasound-guided supraclavicular block according to the various volumes of local anesthetic

    PubMed Central

    Kim, Seok Kon; Kang, Bong Jin; Kwon, Min A; Song, Jae Gyok; Jeon, Soo Mi

    2013-01-01

    Background The ultrasound guidance in regional nerve blocks has recently been introduced and gaining popularity. Ultrasound-guided supraclavicular block has many advantages including the higher success rate, faster onset time, and fewer complications. The aim of this study was to examine the clinical data according to the varied volume of local anesthetics in the ultrasound-guided supraclavicular block. Methods One hundred twenty patients were randomized into four groups, according to the local anesthetic volume used: Group 35 (n = 30), Group 30 (n = 30), Group 25 (n = 30), and Group 20 (n = 30). Supraclavicular blocks were performed with 1% mepivacaine 35 ml, 30 ml, 25 ml, and 20 ml, respectively. The success rate, onset time, and complications were checked and evaluated. Results The success rate (66.7%) was lower in Group 20 than that of Group 35 (96.7%) (P < 0.05). The average onset times of Group 35, Group 30, Group 25, and Group 20 were 14.3 ± 6.9 min, 13.6 ± 4.5 min, 16.7 ± 4.6 min, and 16.5 ± 3.7 min, respectively. There were no significant differences. Horner's syndrome was higher in Group 35 (P < 0.05). Conclusions In conclusion, we achieved 90% success rate with 30 ml of 1% mepivacaine. Therefore, we suggest 30 ml of local anesthetic volume for ultrasound-guided supraclavicular block. PMID:23814648

  20. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    PubMed

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value<0

  1. [Thoracic ultrasound: the pneumologist's new stethoscope].

    PubMed

    Heinen, V; Duysinx, B; Corhay, J L; Louis, R

    2012-10-01

    We now have access to a large library of publications validating transparietal thoracic echography in various clinical situations. Parietal lesions, including osteolysis, can be detected and biopsied during the thoracic ultrasound (TUS) examination. To evaluate the parietal extension of lung cancers, TUS has proved superior to tomodensitometry. Pleural effusions can be easily diagnosed and aspirated. Pneumothoraces can be detected using well defined lung artifacts with a high frequency probe. Pleural and peripheral lung nodules can be detected and biopsied with real time visualization; the procedure is safe and accurate. Lung consolidations with a pleural contact can be diagnosed; this is particularly useful for pregnant women. In conclusion, TUS is a precious diagnostic tool for chosen applications, and can help to guide interventional procedures. The portable devices are also very useful for bedridden patients or for out of hospital use.

  2. Evolution of prostate biopsy techniques. Looking back on a meaningful journey.

    PubMed

    Sivaraman, A; Sanchez-Salas, R; Castro-Marin, M; Barret, E; Guillot-Tantay, C; Prapotnich, D; Cathelineau, X

    2016-10-01

    The technique of prostate biopsy has evolved a long way since its inception to being a safe diagnostic procedure. The principles of the biopsy technique continue to improvise with the knowledge about prostate cancer and availability of newer treatment options like active surveillance and focal therapy. Currently, we depend on accurate cancer information from the biopsy more than ever for deciding the ideal treatment option. The aim of this review is to present the major milestones in prostate biopsy technique evolutions and its impact on the prostate cancer management. We performed a detailed non-systematic literature review to present the historical facts on the transformations in prostate biopsy techniques and also the direction of present research to improve accurate cancer detection. There is a clear change in trend in biopsy technique before and after the introduction of transrectal ultrasound and prostate specific antigen. In the earlier era, the biopsies were aimed at palpable nodules and obtaining adequate prostatic tissue for diagnosis while the later era has moved towards detection of non-palpable and early prostate cancer. Recently, there is an increasing trend towards image guided targeted biopsies to extract maximum cancer information from minimum biopsy cores. Prostate biopsy techniques have seen major changes since its inception and have a major impact on prostate cancer management. There is a great potential for research which can further support the newer treatment options like focal therapy. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. How to Interpret Thyroid Biopsy Results: A Three-Year Retrospective Interventional Radiology Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oppenheimer, Jason D., E-mail: j-oppenheimer@md.northwestern.edu; Kasuganti, Deepa; Nayar, Ritu

    2010-08-15

    Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists undermore » US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.« less

  4. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2018-06-01

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  5. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  6. Treatment of Parkinson's disease in rats by Nrf2 transfection using MRI-guided focused ultrasound delivery of nanomicrobubbles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Ling; Cai, Xiaodong; Guo, Ruomi

    Parkinson's disease (PD) is a very common neurological disorder. However, effective therapy is lacking. Although the blood-brain-barrier (BBB) protects the brain, it prevents the delivery of about 90% of drugs and nucleotides into the brain, thereby hindering the development of gene therapy for PD. Magnetic resonance imaging (MRI)-guided focused ultrasound delivery of microbubbles enhances the delivery of gene therapy vectors across the BBB and improves transfection efficiency. In the present study, we delivered nuclear factor E2-related factor 2 (Nrf2, NFE2L2) contained in nanomicrobubbles into the substantia nigra of PD rats by MRI-guided focused ultrasound, and we examined the effect ofmore » Nrf2 over-expression in this animal model of PD. The rat model of PD was established by injecting 6-OHDA in the right substantia nigra stereotactically. Plasmids (pDC315 or pDC315/Nrf2) were loaded onto nanomicrobubbles, and then injected through the tail vein with the assistance of MRI-guided focused ultrasound. MRI-guided focused ultrasound delivery of nanomicrobubbles increased gene transfection efficiency. Furthermore, Nrf2 gene transfection reduced reactive oxygen species levels, thereby protecting neurons in the target region. - Highlights: • MRI-guided focused ultrasound enhances gene transfection into the brain of rats. • Increased Nrf2 expression protects neurons in the rat model of PD. • Nrf2 protects neurons in PD by inhibiting ROS production.« less

  7. In-vivo ultrasound and photoacoustic image- guided photothermal cancer therapy using silica-coated gold nanorods.

    PubMed

    Kim, Seungsoo; Chen, Yun-Sheng; Luke, Geoffrey P; Emelianov, Stanislav Y

    2014-05-01

    In nanoparticle-augmented photothermal therapy, evaluating the delivery and spatial distribution of nanoparticles, followed by remote temperature mapping and monitoring, is essential to ensure the optimal therapeutic outcome. The utility of ultrasound and photoacoustic imaging to assist photothermal therapy has been previously demonstrated. Here, using a mouse xenograft tumor model, it is demonstrated in vivo that ultrasound-guided photoacoustic imaging can be used to plan the treatment and to guide the therapy. To evaluate nanoparticle delivery and spatial distribution, three-dimensional ultrasound and spectroscopic photoacoustic imaging of a mouse with a tumor was performed before and after intravenous injection of silica-coated gold nanorods. After injection and sufficient circulation of nanoparticles, photothermal therapy was performed for 5 min using an 808-nm continuous-wave laser. During the photothermal therapy, photoacoustic images were acquired continuously and used to measure the temperature changes within tissue. A heterogeneous distribution of temperature, which was spatially correlated with the measured distribution of nanoparticles, indicated that peak temperatures of 53°C were achieved in the tumor. An Arrhenius thermal damage model determined that this thermal deposition would result in significant cell death. The results of this study suggest that ultrasound and photoacoustic imaging can effectively guide photothermal therapy to achieve the desired thermal treatment.

  8. Reproducibility of Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Thermal Lesions in Minimally-Invasive Brain Surgery

    NASA Astrophysics Data System (ADS)

    Zahedi, Sulmaz

    This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.

  9. Transvaginal 3D Image-Guided High Intensity Focused Ultrasound Array

    NASA Astrophysics Data System (ADS)

    Held, Robert; Nguyen, Thuc Nghi; Vaezy, Shahram

    2005-03-01

    The goal of this project is to develop a transvaginal image-guided High Intensity Focused Ultrasound (HIFU) device using piezocomposite HIFU array technology, and commercially-available ultrasound imaging. Potential applications include treatment of uterine fibroids and abnormal uterine bleeding. The HIFU transducer was an annular phased array, with a focal length range of 30-60 mm, an elliptically-shaped aperture of 35×60 mm, and an operating frequency of 3 MHz. A pillow-shaped bag with water circulation will be used for coupling the HIFU energy into the tissue. An intra-cavity imaging probe (C9-5, Philips) was integrated with the HIFU array such that the focal axis of the HIFU transducer was within the image plane. The entire device will be covered by a gel-filled condom when inserted in the vaginal cavity. To control it, software packages were developed in the LabView programming environment. An imaging algorithm processed the ultrasound image to remove noise patterns due to the HIFU signal. The device will be equipped with a three-dimensional tracking system, using a six-degrees-of-freedom articulating arm. Necrotic lesions were produced in a tissue-mimicking phantom and a turkey breast sample for all focal lengths. Various HIFU doses allow various necrotic lesion shapes, including thin ellipsoidal, spherical, wide cylindrical, and teardrop-shaped. Software control of the device allows multiple foci to be activated sequentially for desired lesion patterns. Ultrasound imaging synchronization can be achieved using hardware signals obtained from the imaging system, or software signals determined empirically for various imaging probes. The image-guided HIFU device will provide a valuable tool in visualization of uterine fibroid tumors for the purposes of planning and subsequent HIFU treatment of the tumor, all in a 3D environment. The control system allows for various lesions of different shapes to be optimally positioned in the tumor to cover the entire tumor

  10. Ultrasound-guided fine-needle aspiration biopsy of clinically suspicious thyroid nodules with an automatic aspirator: a novel technique.

    PubMed

    Nagarajah, James; Sheu-Grabellus, Sien-Yi; Farahati, Jamshid; Kamruddin, Kamer A; Bockisch, Andreas; Schmid, Kurt Werner; Görges, Rainer

    2012-07-01

    Fine-needle aspiration biopsy (FNAB) is a simple technique for the investigation of suspicious thyroid nodules. However, low success rates are reported in the literature. The aim of this prospective study was to compare the clinical performance and impact of an automatic aspirator, referred to here as Aspirator 3, to those of the manual technique for the FNAB of clinically suspicious thyroid nodules. One hundred nine consecutive patients with 121 clinically suspicious thyroid nodules underwent a biopsy twice of the same site with the clinically approved Aspirator 3 and with the manual technique. The number of follicular cell formations and the total number of follicular cells in the aspirate were counted using the ThinPrep® method. With the Aspirator 3, the total number and the mean number of extracted cell formations were significantly higher than the values achieved with the manual technique (total: 3222 vs. 1951, p=0.02; mean: 27 vs. 16). The total number of cells that were biopsied was also higher when the Aspirator 3 was utilized (47,480 vs. 23,080, p=0.005). Overall, the Aspirator 3 was superior in 65 biopsies, and the manual technique was superior in 39 biopsies. In terms of cell formations and the total number of cells aspirated, the Aspirator 3 was superior to the manual technique. Further, the Aspirator 3 was more convenient to use and had a greater precision in needle guidance.

  11. Prostate cancer gene 3 and multiparametric magnetic resonance can reduce unnecessary biopsies: decision curve analysis to evaluate predictive models.

    PubMed

    Busetto, Gian Maria; De Berardinis, Ettore; Sciarra, Alessandro; Panebianco, Valeria; Giovannone, Riccardo; Rosato, Stefano; D'Errigo, Paola; Di Silverio, Franco; Gentile, Vincenzo; Salciccia, Stefano

    2013-12-01

    To overcome the well-known prostate-specific antigen limits, several new biomarkers have been proposed. Since its introduction in clinical practice, the urinary prostate cancer gene 3 (PCA3) assay has shown promising results for prostate cancer (PC) detection. Furthermore, multiparametric magnetic resonance imaging (mMRI) has the ability to better describe several aspects of PC. A prospective study of 171 patients with negative prostate biopsy findings and a persistent high prostate-specific antigen level was conducted to assess the role of mMRI and PCA3 in identifying PC. All patients underwent the PCA3 test and mMRI before a second transrectal ultrasound-guided prostate biopsy. The accuracy and reliability of PCA3 (3 different cutoff points) and mMRI were evaluated. Four multivariate logistic regression models were analyzed, in terms of discrimination and the cost benefit, to assess the clinical role of PCA3 and mMRI in predicting the biopsy outcome. A decision curve analysis was also plotted. Repeated transrectal ultrasound-guided biopsy identified 68 new cases (41.7%) of PC. The sensitivity and specificity of the PCA3 test and mMRI was 68% and 49% and 74% and 90%, respectively. Evaluating the regression models, the best discrimination (area under the curve 0.808) was obtained using the full model (base clinical model plus mMRI and PCA3). The decision curve analysis, to evaluate the cost/benefit ratio, showed good performance in predicting PC with the model that included mMRI and PCA3. mMRI increased the accuracy and sensitivity of the PCA3 test, and the use of the full model significantly improved the cost/benefit ratio, avoiding unnecessary biopsies. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Renal Mass Biopsy to Guide Treatment Decisions for Small Incidental Renal Tumors: A Cost-effectiveness Analysis1

    PubMed Central

    Gervais, Debra A.; Hartman, Rebecca I.; Harisinghani, Mukesh G.; Feldman, Adam S.; Mueller, Peter R.; Gazelle, G. Scott

    2010-01-01

    Purpose: To evaluate the effectiveness, cost, and cost-effectiveness of using renal mass biopsy to guide treatment decisions for small incidentally detected renal tumors. Materials and Methods: A decision-analytic Markov model was developed to estimate life expectancy and lifetime costs for patients with small (≤4-cm) renal tumors. Two strategies were compared: renal mass biopsy to triage patients to surgery or imaging surveillance and empiric nephron-sparing surgery. The model incorporated biopsy performance, the probability of track seeding with malignant cells, the prevalence and growth of benign and malignant tumors, treatment effectiveness and costs, and patient outcomes. An incremental cost-effectiveness analysis was performed to identify strategy preference under a willingness-to-pay threshold of $75 000 per quality-adjusted life-year (QALY). Effects of changes in key parameters on strategy preference were evaluated in sensitivity analysis. Results: Under base-case assumptions, the biopsy strategy yielded a minimally greater quality-adjusted life expectancy (4 days) than did empiric surgery at a lower lifetime cost ($3466), dominating surgery from a cost-effectiveness perspective. Over the majority of parameter ranges tested in one-way sensitivity analysis, the biopsy strategy dominated surgery or was cost-effective relative to surgery based on a $75 000-per-QALY willingness-to-pay threshold. In two-way sensitivity analysis, surgery yielded greater life expectancy when the prevalence of malignancy and propensity for biopsy-negative cancers to metastasize were both higher than expected or when the sensitivity and specificity of biopsy were both lower than expected. Conclusion: The use of biopsy to guide treatment decisions for small incidentally detected renal tumors is cost-effective and can prevent unnecessary surgery in many cases. © RSNA, 2010 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10092013/-/DC1 PMID

  13. EBUS-TBNA Provides Highest RNA Yield for Multiple Biomarker Testing from Routinely Obtained Small Biopsies in Non-Small Cell Lung Cancer Patients - A Comparative Study of Three Different Minimal Invasive Sampling Methods

    PubMed Central

    Schmid-Bindert, Gerald; Wang, Yongsheng; Jiang, Hongbin; Sun, Hui; Henzler, Thomas; Wang, Hao; Pilz, Lothar R.; Ren, Shengxiang; Zhou, Caicun

    2013-01-01

    Background Multiple biomarker testing is necessary to facilitate individualized treatment of lung cancer patients. More than 80% of lung cancers are diagnosed based on very small tumor samples. Often there is not enough tissue for molecular analysis. We compared three minimal invasive sampling methods with respect to RNA quantity for molecular testing. Methods 106 small biopsies were prospectively collected by three different methods forceps biopsy, endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA), and CT-guided core biopsy. Samples were split into two halves. One part was formalin fixed and paraffin embedded for standard pathological evaluation. The other part was put in RNAlater for immediate RNA/DNA extraction. If the pathologist confirmed the diagnosis of non-small cell lung cancer(NSCLC), the following molecular markers were tested: EGFR mutation, ERCC1, RRM1 and BRCA1. Results Overall, RNA-extraction was possible in 101 out of 106 patients (95.3%). We found 49% adenocarcinomas, 38% squamouscarcinomas, and 14% non-otherwise-specified(NOS). The highest RNA yield came from endobronchial ultrasound guided needle aspiration, which was significantly higher than bronchoscopy (37.74±41.09 vs. 13.74±15.53 ng respectively, P = 0.005) and numerically higher than CT-core biopsy (37.74±41.09 vs. 28.72±44.27 ng respectively, P = 0.244). EGFR mutation testing was feasible in 100% of evaluable patients and its incidence was 40.8%, 7.9% and 14.3% in adenocarcinomas, squamouscarcinomas and NSCLC NOS subgroup respectively. There was no difference in the feasibility of molecular testing between the three sampling methods with feasibility rates for ERCC1, RRM1 and BRCA1 of 91%, 87% and 81% respectively. Conclusion All three methods can provide sufficient tumor material for multiple biomarkers testing from routinely obtained small biopsies in lung cancer patients. In our study EBUS guided needle aspiration provided the highest amount of

  14. Transrectal EUS-guided FNA biopsy of a presacral chordoma-report of a case and review of the literature

    PubMed Central

    Gottlieb, Klaus; Lin, Paul H; Liu, David M; Anders, Karl

    2008-01-01

    Chordomas are rare tumors which originate from the remnants of the notochord. These tumors are locally aggressive and have a predilection for the ends of the axial skeleton. An important prerequisite for optimal management of these tumors is a correct preoperative diagnosis. The present case is the first report of the use of endoscopic ultrasound to obtain transrectal fine needle aspiration biopsy of a presacral chordoma. A review of the prior computer tomography (CT) scans allowed us to calculate the tumor volume doubling time (18.3 mo). Transrectal biopsy of chordomas is controversial, however we believe that such concerns are not justified. PMID:18442211

  15. Ultrasound-guided platelet-rich plasma injection for distal biceps tendinopathy.

    PubMed

    Barker, Scott L; Bell, Simon N; Connell, David; Coghlan, Jennifer A

    2015-04-01

    Distal biceps tendinopathy is an uncommon cause of elbow pain. The optimum treatment for cases refractory to conservative treatment is unclear. Platelet-rich plasma has been used successfully for other tendinopathies around the elbow. Six patients with clinical and radiological evidence of distal biceps tendinopathy underwent ultrasound-guided platelet-rich plasma (PRP) injection. Clinical examination findings, visual analogue score (VAS) for pain and Mayo Elbow Performance scores were recorded. The Mayo Elbow Performance Score improved from 68.3 (range 65 to 85) (fair function) to 95 (range 85 to 100) (excellent function). The VAS at rest improved from a mean of 2.25 (range 2 to 5) pre-injection to 0. The VAS with movement improved from a mean of 7.25 (range 5 to 8) pre-injection to 1.3 (range 0 to 2). No complications were noted. Ultrasound-guided PRP injection appears to be a safe and effective treatment for recalcitrant cases of distal biceps tendinopathy. Further investigation with a randomized controlled trial is needed to fully assess its efficacy.

  16. Ultrasound-guided platelet-rich plasma injection for distal biceps tendinopathy

    PubMed Central

    Bell, Simon N; Connell, David; Coghlan, Jennifer A

    2015-01-01

    Background Distal biceps tendinopathy is an uncommon cause of elbow pain. The optimum treatment for cases refractory to conservative treatment is unclear. Platelet-rich plasma has been used successfully for other tendinopathies around the elbow. Methods Six patients with clinical and radiological evidence of distal biceps tendinopathy underwent ultrasound-guided platelet-rich plasma (PRP) injection. Clinical examination findings, visual analogue score (VAS) for pain and Mayo Elbow Performance scores were recorded. Results The Mayo Elbow Performance Score improved from 68.3 (range 65 to 85) (fair function) to 95 (range 85 to 100) (excellent function). The VAS at rest improved from a mean of 2.25 (range 2 to 5) pre-injection to 0. The VAS with movement improved from a mean of 7.25 (range 5 to 8) pre-injection to 1.3 (range 0 to 2). No complications were noted. Discussion Ultrasound-guided PRP injection appears to be a safe and effective treatment for recalcitrant cases of distal biceps tendinopathy. Further investigation with a randomized controlled trial is needed to fully assess its efficacy. PMID:27582965

  17. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    PubMed Central

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  18. Simplified stereo-optical ultrasound plane calibration

    NASA Astrophysics Data System (ADS)

    Hoßbach, Martin; Noll, Matthias; Wesarg, Stefan

    2013-03-01

    Image guided therapy is a natural concept and commonly used in medicine. In anesthesia, a common task is the injection of an anesthetic close to a nerve under freehand ultrasound guidance. Several guidance systems exist using electromagnetic tracking of the ultrasound probe as well as the needle, providing the physician with a precise projection of the needle into the ultrasound image. This, however, requires additional expensive devices. We suggest using optical tracking with miniature cameras attached to a 2D ultrasound probe to achieve a higher acceptance among physicians. The purpose of this paper is to present an intuitive method to calibrate freehand ultrasound needle guidance systems employing a rigid stereo camera system. State of the art methods are based on a complex series of error prone coordinate system transformations which makes them susceptible to error accumulation. By reducing the amount of calibration steps to a single calibration procedure we provide a calibration method that is equivalent, yet not prone to error accumulation. It requires a linear calibration object and is validated on three datasets utilizing di erent calibration objects: a 6mm metal bar and a 1:25mm biopsy needle were used for experiments. Compared to existing calibration methods for freehand ultrasound needle guidance systems, we are able to achieve higher accuracy results while additionally reducing the overall calibration complexity. Ke

  19. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration.

    PubMed

    Arakawa, H; Nakajima, Y; Kurihara, Y; Niimi, H; Ishikawa, T

    1996-07-01

    We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.

  20. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    PubMed

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or