Shen, Xu; Zhang, Min; Bhandari, Bhesh; Guo, Zhimei
2018-02-15
In order to investigate the effect of ultrasound dielectric pretreatment on the oxidation resistance of vacuum-fried apple chips, apple slices were pretreated at ultrasonic powers of 150, 250 and 400 W for times of 10, 20 and 30 min before vacuum frying. The quality and oxidation resistance of fried apple were evaluated by testing the dielectric properties and comparing the moisture content, oil uptake, color, acid value (AV) and peroxide value (PV) of apple chips. Ultrasonic treatment significantly changed the dielectric properties of apple slices. Moisture and oil contents of apple chips decreased with increasing ultrasonic power and time. During storage, the color retention of fried apple chips processed by ultrasound was improved. AV and PV values of fried apple chips processed by ultrasound were lower, which improved their antioxidant properties. The results of the present study indicated that ultrasound dielectric pretreatment improved not only the quality of vacuum-fried apple chips but also their antioxidant properties. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
Ultrasound-enhanced nanotherapy of pancreatic cancer
NASA Astrophysics Data System (ADS)
Rapoport, N.; Nam, K.-H.; Christensen, D. A.; Kennedy, A. M.; Shea, J. E.; Scaife, C. L.
2010-03-01
The paper reports in vivo results of ultrasonic nanotherapy of orthotopically grown pancreatic cancer. Phase-shift paclitaxel (PTX) loaded perfluoropentane (PFP) nanoemusions combined with tumor-directed ultrasound have been used with a considerable success for tumor-targeted chemotherapy of gemcitabin (GEM)-refractory pancreatic cancer (PC). The GEM-resistant pancreatic cancer proved sensitive to treatment by a micellar PTX formulation Genexol PM (GEN) andor nanodroplet PTX formulation ndGEN. Due to increased permeability of tumor blood vessels, drug-loaded nanodroplets accumulated in the tumor via passive targeting, which was confirmed by ultrasound imaging. Nanodroplets converted into microbubbles in situ under the action of tumor-directed 1-MHz therapeutic ultrasound. The strongest therapeutic effect was observed for the combination therapy by PTX-loaded nanodroplets, GEM and ultrasound (ndGEN+GEM+ultrasound). This combination therapy resulted in a spectacular tumor regression and in some cases complete tumor resolution. Moreover, formation of metastases was dramatically decreased and ascitis generation was completely suppressed. However for all animal groups, local tumor recurrence was observed after the completion of the treatment indicating that some cancer cells survived the treatment. The recurrent tumors proved more resistant to the repeated therapy than initial tumors.
Jenks, Christopher L; Hernandez, Ana; Stavinoha, Peter L; Morris, Michael C; Tian, Fenghua; Liu, Hanli; Garg, Parvesh; Forbess, Joseph M; Koch, Joshua
To determine if a non-invasive, repeatable test can be used to predict neurodevelopmental outcomes in patients with congenital heart disease. This was a prospective study of pediatric patients less than two months of age undergoing congenital heart surgery at the Children's Health Children's Medical Center at Dallas. Multichannel near-infrared spectroscopy (NIRS) was utilized during the surgery, and ultrasound (US) resistive indices (RI) of the major cranial vessels were obtained prior to surgery, immediately post-operatively, and prior to discharge. Pearson's correlation, Fischer exact t test, and Fischer r to z transformation were used where appropriate. A total of 16 patients were enrolled. All had US data. Of the sixteen patients, two died prior to the neurodevelopmental testing, six did not return for the neurodevelopmental testing, and eight patients completed the neurodevelopmental testing. There were no significant correlations between the prior to surgery and prior to discharge US RI and neurodevelopmental outcomes. The immediate post-operative US RI demonstrated a strong positive correlation with standardized neurodevelopmental outcome measures. We were able to demonstrate qualitative differences using multichannel NIRS during surgery, but experienced significant technical difficulties implementing consistent monitoring. A higher resistive index in the major cerebral blood vessels following cardiac surgery in the neonatal period is associated with improved neurological outcomes one year after surgery. Obtaining an ultrasound with resistive indices of the major cerebral vessels prior to and after surgery may yield information that is predictive of neurodevelopmental outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.
Cancel, Limary M; Tarbell, John M; Ben-Jebria, Abdellaziz
2004-09-01
Transdermal drug delivery offers an alternative to injections and oral medication but is limited by the low skin permeability of most drugs. The use of low-frequency ultrasound over long periods of time, typically over an hour, has been shown to enhance skin permeability, a phenomenon referred to as sonophoresis. In this study, we investigated the effects of short time sonication of human skin at 20 kHz and at variable intensities and duty cycles on the dynamics of fluorescein transport across the skin (permeability) as well as the changes in the skin's structural integrity (electrical resistance). We found that a short application of ultrasound enhanced the transport of fluorescein across human skin by a factor in the range of 2-9 for full thickness skin samples and by a factor in the range of 2-28 000 for heat-stripped stratum corneum samples (however, samples with very high (10(3)) enhancement were likely to have been damaged by ultrasound). The electrical resistance of the skin decreased by an average of 20% for full thickness samples and 58% for stratum corneum samples. Increasing the duty cycle from 10 to 60% caused a significant increase in permeability enhancement from 2.3 to 9.1, and an increase in intensity from 8 to 23 mW cm(-2) induced a significant increase in permeability enhancement from 2 to 7.4, indicating a clear dependence of the permeability on both duty cycle and intensity. The increase in solute flux upon ultrasound exposure was immediate, demonstrating for the first time the fast response dynamics of sonophoretic enhancement. In addition, a quantitative analysis of the thermal and convective dispersion effects associated with ultrasound application showed that each contributes significantly to the overall permeability enhancement observed.
Theranostic Oxygen Delivery Using Ultrasound and Microbubbles
Kwan, James J.; Kaya, Mehmet; Borden, Mark A.; Dayton, Paul A.
2012-01-01
Means to overcome tumor hypoxia have been the subject of clinical investigations since the 1960's; however these studies have yet to find a treatment which is widely accepted. It has been known for nearly a century that hypoxic cells are more resistant to radiotherapy than aerobic cells, and tumor hypoxia is a major factor leading to the resistance of tumors to radiation treatment as well as several cytotoxic agents. In this manuscript, the application of ultrasound combined with oxygen-carrier microbubbles is demonstrated as a method to locally increase dissolved oxygen. Microbubbles can also be imaged by ultrasound, thus providing the opportunity for image-guided oxygen delivery. Simulations of gas diffusion and microbubble gas exchange show that small amounts (down to 5 vol%) of a low-solubility osmotic gas can substantially increase microbubble persistence and therefore production rates and stability of oxygen-carrier microbubbles. Simulations also indicate that the lipid shell can be engineered with long-chain lipids to increase oxygen payload during in vivo transit. Experimental results demonstrate that the application of ultrasound to destroy the microbubbles significantly enhances the local oxygen release. We propose this technology as an application for ultrasound image-guided release of oxygen directly to hypoxic tissue, such as tumor sites to enhance radiotherapy. PMID:23382774
Rosato, E; Barbano, B; Gigante, A; Cianci, R; Molinaro, I; Quarta, S; Digiulio, M A; Messineo, D; Pisarri, S; Salsano, F
2013-01-01
Erectile dysfunction (ED) prevalence in male systemic sclerosis (SSc) is high and its pathogenesis is unclear. The aim of the study is to assess correlation between Doppler ultrasound indices of penis and kidneys or digital arteries in male systemic sclerosis. Fourteen men with systemic sclerosis were enrolled in this study. Erectile function was investigated by the International Index of Erectile Function-5. Peak systolic velocity, end diastolic velocity, resistive index, pulsative index, and systolic/diastolic ratio were measured on the cavernous arteries at the peno-scrotal junction in the flaccid state, on the interlobar artery of both kidneys and all ten proper palmar digital arteries. Ten (71 percent) patients have an International Index of Erectile Function-5 less than 21. Reduction of penis peak systolic velocity was observed in all SSc subjects. Doppler indices of cavernous arteries correlate with the International Index of Erectile Function-5. The renal and digital arteries resistive index demonstrated a good correlation (p less than 0.0001) with International Index of Erectile Function-5. A positive correlation exists between penis and kidney arteries Doppler indices: end diastolic velocity (p less than 0.05, r=0.54), resistive index (p less than 0.0001, r=0.90), systolic/diastolic ratio (p less than 0.01, r=0.69). A positive correlation was observed between penis and digital arteries Doppler indices: peak systolic velocity (p less than 0.01, r=0.68), end diastolic velocity (p less than 0.01, r=0.75), resistive index (p less than 0.001, r=0.79), systolic/diastolic ratio (p less than 0.05, r=0.59). A correlation exists between arterial impairment of penis and renal or digital arteries.
García-Criado, Angeles; Gilabert, Rosa; Bianchi, Luis; Vilana, Ramón; Burrel, Marta; Barrufet, Marta; Oliveira, Rafael; García-Valdecasas, Juan Carlos; Brú, Concepción
2015-01-01
To assess the value of contrast-enhanced ultrasound (CEUS) in the absence of hepatic artery signal on Doppler ultrasound (DUS) in the immediate postoperative period after liver transplant. This prospective study included 675 consecutive liver transplants. Patients without hepatic artery signal by DUS within 8 days post-transplant were studied with CEUS. If it remained undetectable, a thrombosis was suspected. In patent hepatic artery, a DUS was performed immediately after CEUS; if low resistance flow was detected, an arteriography was indicated. Patients with high resistance waveform underwent DUS+/CEUS follow-up. Arteriography was indicated when abnormal flow persisted for more than 5 days or liver dysfunction appeared. Thirty-four patients were studied with CEUS. In 11 patients CEUS correctly diagnosed hepatic artery thrombosis. In two out of 23 non-occluded arteries, a low resistance flow lead to a diagnosis of stenosis/proximal thrombosis. Twenty-one patients had absence of diastolic flow, which normalized in the follow-up in 13 patients. In the remaining eight patients, splenic artery steal syndrome (ASS) was diagnosed. CEUS allows us to avoid invasive tests in the diagnostic work-up shortly after liver transplant. It identifies the hepatic artery thrombosis and points to a diagnosis of ASS. • CEUS is useful in the diagnostic work-up shortly after liver transplant • CEUS identifies the hepatic artery thrombosis with reliability • There is little information about DUS and CEUS findings in the ASS • DUS and CEUS offer functional information useful in the diagnosis of ASS.
Gobato, Amanda Oliva; Vasques, Ana Carolina J.; Yamada, Roberto Massao; Zambon, Mariana Porto; Barros-Filho, Antonio de Azevedo; Hessel, Gabriel
2014-01-01
OBJECTIVE: To describe the prevalence of hepatic steatosis and to assess the performance of biochemical, anthropometric and body composition indicators for hepatic steatosis in obese teenagers. METHODS: Cross-sectional study including 79 adolecents aged from ten to 18 years old. Hepatic steatosis was diagnosed by abdominal ultrasound in case of moderate or intense hepatorenal contrast and/or a difference in the histogram ≥7 on the right kidney cortex. The insulin resistance was determined by the Homeostasis Model Assessment-Insulin Resistance (HOMA-IR) index for values >3.16. Anthropometric and body composition indicators consisted of body mass index, body fat percentage, abdominal circumference and subcutaneous fat. Fasting glycemia and insulin, lipid profile and hepatic enzymes, such as aspartate aminotransferase, alanine aminotransferase, gamma-glutamyltransferase and alkaline phosphatase, were also evaluated. In order to assess the performance of these indicators in the diagnosis of hepatic steatosis in teenagers, a ROC curve analysis was applied. RESULTS: Hepatic steatosis was found in 20% of the patients and insulin resistance, in 29%. Gamma-glutamyltransferase and HOMA-IR were good indicators for predicting hepatic steatosis, with a cutoff of 1.06 times above the reference value for gamma-glutamyltransferase and 3.28 times for the HOMA-IR. The anthropometric indicators, the body fat percentage, the lipid profile, the glycemia and the aspartate aminotransferase did not present significant associations. CONCLUSIONS: Patients with high gamma-glutamyltransferase level and/or HOMA-IR should be submitted to abdominal ultrasound examination due to the increased chance of having hepatic steatosis. PMID:25119755
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nam, Kweon-Ho; Christensen, Douglas A.; Rapoport, Natalya
2009-04-14
Acoustic and therapeutic properties of Doxorubicin (DOX) and paclitaxel (PTX)-loaded perfluorocarbon nanoemulsions have been investigated in a mouse model of ovarian cancer. The nanoemulsions were stabilized by two biodegradable amphiphilic block copolymers that differed in the structure of the hydrophobic block. Acoustic droplet vaporization (ADV) and cavitation parameters were measured as a function of ultrasound frequency, pressure, duty cycles, and temperature. The optimal parameters that induced ADV and inertial cavitation of the formed microbubbles were used in vivo in the experiments on the ultrasound-mediated chemotherapy of ovarian cancer. A combination tumor treatment by intravenous injections of drug-loaded perfluoropentane nanoemulsions andmore » tumor-directed 1-MHz ultrasound resulted in a dramatic decrease of ovarian or breast carcinoma tumor volume and sometimes complete tumor resolution. However, tumors often recurred three to six weeks after the treatment indicating that some cancer cells survived the treatment. The recurrent tumors proved more aggressive and resistant to the repeated therapy than initial tumors suggesting selection for the resistant cells during the first treatment.« less
Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon
2018-03-01
To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.
Baghbani, Fatemeh; Moztarzadeh, Fathollah
2017-05-01
Ultrasound-responsive perfluorocarbon nanoemulsions are a class of new multifunctional smart nanocarriers which combine diagnostic properties with therapeutic properties and release their drug payload in a controlled manner in response to ultrasound. Therefore, combination therapy using chemotherapeutic and chemosensitizing agents co-entrapped in these nanocarriers seems beneficial for cancer treatment. In the present study, multifunctional smart alginate/perfluorohexane nanodroplets were developed for co-delivery of doxorubicin and curcumin (a strong chemosensitizer). The nanodroplets with the average particle size of 55.1nm were synthesized via nanoemulsion process. The entrapment efficiency of doxorubicin was 92.3%. To improve curcumin entrapment into the alginate shell, Span 60 was added to the formulation as a co-surfactant and finally curcumin entrapment of about 40% was achieved. Ultrasound-mediated drug release kinetic was evaluated at two different frequencies of 28kHz (low frequency) and 1MHz (high frequency). Low frequency ultrasound resulted in higher triggered drug release from nanodroplets. The nanodroplets showed strong ultrasound contrast via droplet to bubble transition as confirmed via B-mode ultrasound imaging. Enhanced cytotoxicity in adriamycin-resistant A2780 ovarian cancer cells was observed for Dox-Cur-NDs compared to Dox-NDs because of the synergistic effects of doxorubicin and curcumin. However, ultrasound irradiation significantly increased the cytotoxicity of Dox-Cur-NDs. Finally, in vivo ovarian cancer treatment using Dox/Cur-NDs combined with ultrasound irradiation resulted in efficient tumor regression. According to the present study, nanotherapy of multidrug resistant human ovarian cancer using ultrasound responsive doxorubicin/curcumin co-loaded alginate-shelled nanodroplets combined with ultrasound irradiation could be a promising modality for the future of cancer treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Gaschen, Lorrie; Kircher, Patrick
2007-08-01
Sonography is an important diagnostic tool to examine the gastrointestinal tract of dogs with chronic diarrhea. Two-dimensional grayscale ultrasound parameters to assess for various enteropathies primarily focus on wall thickness and layering. Mild, generalized thickening of the intestinal wall with maintenance of the wall layering is common in inflammatory bowel disease. Quantitative and semi-quantitative spectral Doppler arterial waveform analysis can be utilized for various enteropathies, including inflammatory bowel disease and food allergies. Dogs with inflammatory bowel disease have inadequate hemodynamic responses during digestion of food. Dogs with food allergies have prolonged vasodilation and lower resistive and pulsatility indices after eating allergen-inducing foods.
Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?
Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V
2015-12-01
Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.
Tao, Yang; Wang, Ping; Wang, Yilin; Kadam, Shekhar U; Han, Yongbin; Wang, Jiandong; Zhou, Jianzhong
2016-07-01
The effect of ultrasound pretreatment prior to convective drying on drying kinetics and selected quality properties of mulberry leaves was investigated in this study. Ultrasound pretreatment was carried out at 25.2-117.6 W/L for 5-15 min in a continuous mode. After sonication, mulberry leaves were dried in a hot-air convective dryer at 60 °C. The results revealed that ultrasound pretreatment not only affected the weight of mulberry leaves, it also enhanced the convective drying kinetics and reduced total energy consumption. The drying kinetics was modeled using a diffusion model considering external resistance and effective diffusion coefficient De and mass transfer coefficient hm were identified. Both De and hm during convective drying increased with the increase of acoustic energy density (AED) and ultrasound duration. However, De and hm increased slowly at high AED levels. Furthermore, ultrasound pretreatment had a more profound influence on internal mass transfer resistance than on external mass transfer resistance during drying according to Sherwood numbers. Regarding the quality properties, the color, antioxidant activity and contents of several bioactive compounds of dried mulberry leaves pretreated by ultrasound at 63.0 W/L for 10 min were similar to that of mulberry leaves without any pretreatments. Overall, ultrasound pretreatment is effective to shorten the subsequent drying time of mulberry leaves without damaging the quality of final product. Copyright © 2016 Elsevier B.V. All rights reserved.
Influence of ultrasound on the heterogeneous Fenton-like oxidation of acetic acid.
Cihanoğlu, Aydın; Gündüz, Gönül; Dükkancı, Meral
2017-11-01
The main objective of this study is to investigate the effect of ultrasound on the heterogeneous Fenton-like oxidation of acetic acid, which is one of the most resistant carboxylic acids to oxidation. For this purpose, firstly, the degradation of acetic acid was examined by using ultrasound alone and the effects of different parameters such as: type of sonication system, ultrasonic power, and addition of H 2 O 2 were investigated on the degradation of acetic acid. There was no chemical oxygen demand (COD) reduction in the presence of sonication alone. In the presence of the heterogeneous Fenton-like oxidation process alone, at 303 K, COD reduction reached only 7.1% after 2 h of reaction. However, the combination of the heterogeneous Fenton-like oxidation process with ultrasound increased the COD reduction from 7.1% to 25.5% after 2 h of reaction in an ultrasonic bath operated at 40 kHz, while the COD reduction only increased from 7.1% to 8.9% in the ultrasonic reactor operated at 850 kHz. This result indicates that the hybrid process of ultrasound and heterogeneous Fenton-like oxidation is a promising process to degrade acetic acid.
Stock, K F; Klein, B S; Cong, M T Vo; Regenbogen, C; Kemmner, S; Büttner, M; Wagenpfeil, S; Matevossian, E; Renders, L; Heemann, U; Küchle, C
2011-01-01
Beyond the medical history, the clinical exam and lab findings, non-invasive ultrasound parameters such as kidney size and Doppler values (e.g. the resistive index) are important tools assisting clinical decision making in the monitoring of renal allografts. The gold standard for the diagnosis of renal allograft dysfunction remains the renal biopsy; while an invasive procedure, the justifiable necessity for this derives from its definitive nature a requirement beyond the synopses of all non-invasive tools. "Acoustic Radiation Force Impulse Imaging"(ARFI)-quantification is a novel ultrasound-based technology measuring tissue elasticity properties. So far experience related to this new method has not been reported in renal transplant follow-up. The purpose of this study was to evaluate changes in ARFI-measurements between clinically stable renal allografts and biopsy-proven transplant dysfunction. We employed "Virtual Touch™ tissue quantification" (Siemens Acuson, S2000) for the quantitative measurement of tissue stiffness in the cortex of transplant kidneys. We performed initial baseline and later disease-evaluative ultrasound examinations in 8 renal transplant patients in a prospective study design. Patients were first examined during stable allograft function with a routine post-transplant renal ultrasound protocol. A second follow-up examination was carried out on subsequent presentation with transplant dysfunction prior to allograft biopsy and histological evaluation. All patiens were examined using ARFI-quantification (15 measurements/kidney). Resistive indices (RI) were calculated using pulsed-wave Doppler ultrasound, and transplant kidney size was measured on B-mode ultrasound images. All biopsies were evaluated histologically by a reference nephropathologist unaware of the results of the ultrasound studies. Histopathological diagnoses were based on biopsy results, taking clinical and laboratory findings into account. Finally we calculated the relative changes in ARFI-quantification, resistive indices and the absolute change of kidney size on a percentage basis at these defined assessment times and compared the results with the final pathologic diagnosis. Histological results enumerated five cases of acute T-cell-mediated rejection, one case of calcineurin inhibitor toxicity and two cases of acute tubular necrosis. Calcineurin inhibitor toxicity and acute tubular necrosis were subsumed as "other pathologies". Mean ARFI-values showed an average increase of more than 15% percent in transplants with histologically proven acute rejection whereas no increase was seen in transplants with other pathologies. Mean RI-values showed no increase either in the diagnostic group of acute rejection, nor in the group with other pathologies. Kidney size showed a mean absolute increase of 0.5 centimetres in allografts with acute rejection, whereas a mean decrease of 0.17 centimetres was seen in the group with other pathologies. As shown before in other studies, RI values and kidney size are of doubtful utility in the evaluation of kidney allograft dysfunction. ARFI-based elasticity measurement shows promise as a complementary non-invasive parameter in follow-on diagnosis of renal allograft rejection.
Ultrasound-Assisted Hot Air Drying of Foods
NASA Astrophysics Data System (ADS)
Mulet, Antonio; Cárcel, Juan Andrés; García-Pérez, José Vicente; Riera, Enrique
This chapter deals with the application of power ultrasound, also named high-intensity ultrasound, in the hot air drying of foods. The aim of ultrasound-assisted drying is to overcome some of the limitations of traditional convective drying systems, especially by increasing drying rate without reducing quality attributes. The effects of ultrasound on drying rate are responsible for some of the phenomena produced in the internal and/or external resistance to mass transfer.
Influence of Ultrasound Treatment on Cavitation Erosion Resistance of AlSi7 Alloy
Pola, Annalisa; Montesano, Lorenzo; Tocci, Marialaura; La Vecchia, Giovina Marina
2017-01-01
Ultrasound treatment of liquid aluminum alloys is known to improve mechanical properties of castings. Aluminum foundry alloys are frequently used for production of parts that undergo severe cavitation erosion phenomena during service. In this paper, the effect of the ultrasound treatment on cavitation erosion resistance of AlSi7 alloy was assessed and compared to that of conventionally cast samples. Cavitation erosion tests were performed according to ASTM G32 standard on as-cast and heat treated castings. The response of the alloy in each condition was investigated by measuring the mass loss as a function of cavitation time and by analyzing the damaged surfaces by means of optical and scanning electron microscope. It was pointed out that the ultrasound treatment increases the cavitation erosion resistance of the alloy, as a consequence of the higher chemical and microstructural homogeneity, the finer grains and primary particles and the refined structure of the eutectic induced by the treatment itself. PMID:28772617
Influence of Ultrasound Treatment on Cavitation Erosion Resistance of AlSi7 Alloy.
Pola, Annalisa; Montesano, Lorenzo; Tocci, Marialaura; La Vecchia, Giovina Marina
2017-03-03
Ultrasound treatment of liquid aluminum alloys is known to improve mechanical properties of castings. Aluminum foundry alloys are frequently used for production of parts that undergo severe cavitation erosion phenomena during service. In this paper, the effect of the ultrasound treatment on cavitation erosion resistance of AlSi7 alloy was assessed and compared to that of conventionally cast samples. Cavitation erosion tests were performed according to ASTM G32 standard on as-cast and heat treated castings. The response of the alloy in each condition was investigated by measuring the mass loss as a function of cavitation time and by analyzing the damaged surfaces by means of optical and scanning electron microscope. It was pointed out that the ultrasound treatment increases the cavitation erosion resistance of the alloy, as a consequence of the higher chemical and microstructural homogeneity, the finer grains and primary particles and the refined structure of the eutectic induced by the treatment itself.
Novel design of low noise preamplifier for medical ultrasound transducers.
Amer, Mashhour Bani
2011-02-01
A novel design of low noise amplifier for medical ultrasound transducers is described in this paper. Unlike conventional low noise preamplifiers, this design proposes a new circuit configuration which has electronically adjustable matching resistance that allows the preamplifier to be compatible with a variety of medical ultrasound transducers. The design employs current feedback operational amplifier to enhance the gain-bandwidth independence and improve the design slew rate. Simulation results show that the proposed design has very low output noise voltage spectral density and the level of this noise does not increase when its tunable matching resistance is increased or decreased.
Dong, Yuan; Cui, Cheng-Bin; Li, Chang-Wei; Hua, Wei; Wu, Chang-Jing; Zhu, Tian-Jiao; Gu, Qian-Qun
2014-07-29
A new ultrasound-mediated approach has been developed to introduce neomycin-resistance to activate silent pathways for secondary metabolite production in a bio-inactive, deep-sea fungus, Aspergillus versicolor ZBY-3. Upon treatment of the ZBY-3 spores with a high concentration of neomycin by proper ultrasound irradiation, a total of 30 mutants were obtained by single colony isolation. The acquired resistance of the mutants to neomycin was confirmed by a resistance test. In contrast to the ZBY-3 strain, the EtOAc extracts of 22 of the 30 mutants inhibited the human cancer K562 cells, indicating that these mutants acquired a capability to produce antitumor metabolites. HPLC-photodiode array detector (PDAD)-UV and HPLC-electron spray ionization (ESI)-MS analyses of the EtOAc extracts of seven bioactive mutants and the ZBY-3 strain indicated that diverse secondary metabolites have been newly produced in the mutant extracts in contrast to the ZBY-3 extract. The followed isolation and characterization demonstrated that six metabolites, cyclo(D-Pro-D-Phe) (1), cyclo(D-Tyr-D-Pro) (2), phenethyl 5-oxo-L-prolinate (3), cyclo(L-Ile-L-Pro) (4), cyclo(L-Leu-L-Pro) (5) and 3β,5α,9α-trihydroxy-(22E,24R)-ergosta-7,22-dien-6-one (6), were newly produced by the mutant u2n2h3-3 compared to the parent ZBY-3 strain. Compound 3 was a new compound; 2 was isolated from a natural source for the first time, and all of these compounds were also not yet found in the metabolites of other A. versicolor strains. Compounds 1-6 inhibited the K562 cells, with inhibition rates of 54.6% (1), 72.9% (2), 23.5% (3), 29.6% (4), 30.9% (5) and 51.1% (6) at 100 μg/mL, and inhibited also other human cancer HL-60, BGC-823 and HeLa cells, to some extent. The present study demonstrated the effectiveness of the ultrasound-mediated approach to activate silent metabolite production in fungi by introducing acquired resistance to aminoglycosides and its potential for discovering new compounds from silent fungal metabolic pathways. This approach could be applied to elicit the metabolic potentials of other fungal isolates to discover new compounds from cryptic secondary metabolites.
Prognostic value of three-dimensional ultrasound for fetal hydronephrosis
WANG, JUNMEI; YING, WEIWEN; TANG, DAXING; YANG, LIMING; LIU, DONGSHENG; LIU, YUANHUI; PAN, JIAOE; XIE, XING
2015-01-01
The present study evaluated the prognostic value of three-dimensional ultrasound for fetal hydronephrosis. Pregnant females with fetal hydronephrosis were enrolled and a novel three-dimensional ultrasound indicator, renal parenchymal volume/kidney volume, was introduced to predict the postnatal prognosis of fetal hydronephrosis in comparison with commonly used ultrasound indicators. All ultrasound indicators of fetal hydronephrosis could predict whether postnatal surgery was required for fetal hydronephrosis; however, the predictive performance of renal parenchymal volume/kidney volume measurements as an individual indicator was the highest. In conclusion, ultrasound is important in predicting whether postnatal surgery is required for fetal hydronephrosis, and the three-dimensional ultrasound indicator renal parenchymal volume/kidney volume has a high predictive performance. Furthermore, the majority of cases of fetal hydronephrosis spontaneously regress subsequent to birth, and the regression time is closely associated with ultrasound indicators. PMID:25667626
Anticorrosion efficiency of ultrasonically deposited silica coatings on titanium
NASA Astrophysics Data System (ADS)
Ertaş, Fatma Sinem; Kaş, Recep; Mikó, Annamária; Birer, Özgür
2013-07-01
We utilized high intensity ultrasound to prepare coatings of silica and organically modified silica composed of multiple layers of densely packed nanoparticles. Ultrasound was used to collide nanoparticles onto an activated titanium surface with high speed. Large areas could be homogeneously coated by this method. These coatings were characterized by spectroscopy and microscopy methods and the anticorrosion efficiency in NaCl solution was evaluated by electrochemical measurements. The results indicated that the composite coatings provided good quality barrier layer on bare titanium and decreased the anodic corrosion rate. It was found that increase in the organic content of the coating shifted the passivation potential towards more positive direction. The comparison of the impedance results recorded at the corrosion potential pointed out that in each case a good quality barrier layer was formed on the titanium surface. The outstanding corrosion resistance of the composite coatings with only ~200 nm thickness shows that ultrasound assisted deposition can be a competitive method to obtain corrosion protective layers.
Wawrzyk, Magdalena; Sokal, Jan; Andrzejewska, Ewa; Przewratil, Przemysław
2015-01-01
In the process of diagnosis and treatment of fractures, an X-ray study is typically performed. In modern medicine very important is the development of new diagnostic methods without adverse effects on the body. One of such techniques is ultrasound imaging. It has a high value in imaging most areas of the body, including the musculoskeletal system. Reports on the use of ultrasound in the evaluation of the callus are rare and this could be a method equivalent to or even better than standard radiographs. The aim of the study was to analyze the correlation of ultrasound with radiographs in imaging of callus formation after fractures of long bones in children and to analyze the correlation of vascular resistance index (RI) and the degree of vascularization of the callus with a subjective radiological assessment of the bone union quality. The prospective study was planned to qualify 50 children treated for long bones fractures of the arm, forearm, thigh and lower leg. Ultrasound diagnosis was carried out using a Philips iU22 camera equipped with a linear probe with 17-5-MHz resolution and MSK Superficial program. During ultrasound examination measurements of the callus were performed. Using the Power Doppler callus vascularity was visualized and vascular resistance index (RI) was measured. The same measurements were made within the corresponding area of the healthy limb. The results obtained by ultrasound were compared with radiograph measurements and with the subjective assessment of the callus quality. Preliminary results were developed on a group of 24 patients, where 28 fractured bones and 28 corresponding healthy bones were examined. Fifteen boys and 9 girls participated in the study. The average age at injury was, respectively, 11 and 9 years. In both groups fractures without displacement were the most frequent. A similar frequency was observed in fractures requiring reposition and subperiosteal fractures. In contrast, fractures with a slight displacement of the fragments, were 3 times more common in girls. Statistical analysis of the measurements of length and width of the callus demonstrated that the differences between results obtained in the ultrasound in comparison with X-rays were not statistically significant. Moreover, preliminary results showed a significantly higher degree of vascularization of the callus than of the healthy periosteum. Preliminary results indicate the high efficacy of ultrasound in the evaluation of callus formation after fractures of long bones in children and the possibility of its alternative use to X-ray examinations.
[Ultrasonographic study of blood flow in the renal arteries of patients with arterial hypertension].
Makarenko, E S; Dombrovskiĭ, V I; Nelasov, N Iu
2012-01-01
Vascular duplex ultrasound duplex with simultaneous ECG registration was made to estimate the quantitative and time parameters of blood flow in the renal arteries with grade 1-2 arterial hypertension. There were increases in vascular resistance indices and acceleration phase index and a reduction in systolic phase index. There were correlations of the time parameters of blood flow in the renal arteries with age and lipidogram values.
Treatment of great auricular neuralgia with real-time ultrasound-guided great auricular nerve block
Jeon, Younghoon; Kim, Saeyoung
2017-01-01
Abstract Rationale: The great auricular nerve can be damaged by the neck surgery, tumor, and long-time pressure on the neck. But, great auricular neuralgia is very rare condition. It was managed by several medication and landmark-based great auricular nerve block with poor prognosis. Patient concerns: A 25-year-old man presented with a pain in the left lateral neck and auricle. Diagnosis: He was diagnosed with great auricular neuralgia. Interventions: His pain was not reduced by medication. Therefore, the great auricular nerve block with local anesthetics and steroid was performed under ultrasound guidance. Outcomes: Ultrasound guided great auricular nerve block alleviated great auricular neuralgia. Lessons: This medication-resistant great auricular neuralgia was treated by the ultrasound guided great auricular nerve block with local anesthetic agent and steroid. Therefore, great auricular nerve block can be a good treatment option of medication resistant great auricular neuralgia. PMID:28328811
Progesterone increases resistance of ophthalmic and central retinal arteries in climacteric women.
Souza, M A M De; Souza, B M De; Geber, S
2013-04-01
To evaluate the effect of a synthetic progestin on the vascular resistance of the ophthalmic and central retinal arteries in climacteric women, compared to placebo, using transorbital ultrasound with Doppler velocimetry. We performed a prospective, randomized, double-blinded, placebo-controlled study with 216 climacteric women. Subjects were randomly allocated to one of two groups: either the group receiving placebo (one pill/day for 30 days) (n = 108) or the group receiving progestin (5 mg medroxyprogesterone acetate/day for 30 days) (n = 108). Transorbital Doppler velocimetric ultrasound was performed, before and after treatment; we measured the pulsatility index, resistance index and systole/diastole ratio. The mean ages of the participants in the study group and the control group were 54 ± 6.2 years (range 48-59 years) and 55 ± 6.8 years (range 46-60 years), respectively. When we compared the effect of the progestin on the central retinal artery before and after treatment, we observed a significant increase after the treatment in all Doppler indices. The same was observed when we compared the effect of the progestin on the ophthalmic artery. In the group of women receiving placebo, the Doppler indices were similar before and after treatment. Our results demonstrate the existence of a progestogenic vasoconstrictive effect in the ophthalmic and central retinal arteries. As this study provides new data, the observed effect needs further investigations to better elucidate its extent. Moreover, our findings may be particularly useful to others interested in understanding the vascular dynamics of the cerebral vessels and to researchers running clinical trials related to hormone replacement therapy.
Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index.
Elec, Florin Ioan; Lucan, Ciprian; Ghervan, Liviu; Munteanu, Valentin; Moga, Silviu; Suciu, Mihai; Enache, Dan; Elec, Alina; Munteanu, Adriana; Barbos, Adrian; Iacob, Gheorghita; Lucan, Mihai
2014-01-01
With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity for a better life quality. The aim of this study is to evaluate the relation between the resistance index provided by the PM, the postoperative resistance index measured by Doppler ultrasound and the initial graft outcome. Between January 2012-December 2012, clinical data obtained from 82 consecutive renal transplants from brain death donors (BDD) which underwent PM maintenance were analyzed in a transversal study. Prior transplantation we recorded the solution temperature, filtration rate and the resistance index provided by PM. After the surgical intervention, each patient had standard follow-up. Doppler ultrasound resistivity index (RI) was recorded on the first postoperative day. Out of 115 renal transplants, 98 (85.21%) were performed with grafts from BDD. The PM was used for 82 renal grafts. The Doppler resistance index in relation to the resistance index shows a highly statistical correlation by linear regression (R=0.813, p<0.0001). Primary graft function was recorded in 74 patients (90.24%) and it was highly statistically significant correlated with the resistance index measured by PM. Out of 8 patients with primary non-function, 6 patients recovered with normal graft function at one year. The resistivity index recorded by the life-port machine is correlated with the vascular resistivity index measured by Doppler ultrasound and thus it may predicts the primary graft outcome.
Tebbetts, J B
1998-10-01
Numerous complications and increased operating times were reported with ultrasonically assisted lipoplasty in the first several months after introduction of the technology in the United States. The purpose of this study was to review early reported complications and management regimens, evaluate possible causes of problems, and apply indications and techniques to attempt to minimize complications during an initial experience with this technique beginning in January of 1997. Seven specific indications and modifications of existing techniques were developed and applied to an initial clinical series of 70 consecutive patients who underwent ultrasound-assisted suction lipoplasty between January 10, 1997, and August 1, 1997. Follow-up ranged from 1 to 7 months. No perioperative or postoperative complication occurred in any patient in this series. In this series of ultrasound-assisted lipoplasty cases, application of the following criteria resulted in a series of 70 patients with 1 to 7-month follow-up without complications: (1) selecting patients with well localized fat deposits who were no more than 20 percent above their ideal body weight; (2) infusing a solution of Ringer's Lactate containing 1 cc of 1:1000 epinephrine per 1000 cc into the area of fat removal, stopping infusion when the tissues first become firm, not infusing to marked tissue turgor or skin induration; (3) restricting the level of energy application to a minimum of 1 cm from the undersurface of the dermis; (4) limiting ultrasonic energy application in each area to approximately 1 minute per estimated 100 cc of total aspirate in a wet to superwet environment; (5) not performing ultrasound-assisted lipoplasty in the same area as another procedure that could potentially compromise tissue vascularity; (6) using a Lysonix 2000 generator and 5-mm golf tee tip probe at a power setting of 8 to apply ultrasonic energy to the area of fat removal, ceasing energy application when tissue resistance to the passage of the probe decreases and moving the cannula as rapidly as tissue resistance allows; and (7) using a standard elastic garment without adherent foam or other materials for 2 weeks postoperatively, encouraging all normal activity immediately, and restricting aerobic activities for 2 weeks.
Non-invasive Renal Denervation: Update on External Ultrasound Approaches.
Schmieder, Roland E; Ott, Christian; Bramlage, Peter
2016-06-01
In the last decade, intravenous renal denervation (RDN) has emerged as an alternative to pharmacological treatment in patients with resistant hypertension, but currently involves an invasive and technically challenging procedure. The Surround Sound™ system utilises externally delivered ultrasound to achieve RDN using a completely non-invasive, automated real-time tracking system coupled with a therapeutic delivery module thereby addressing these limitations. A brief history, technical overview and summary of preclinical and clinical studies of the KonaMedical Surround Sound™ system are presented. A literature search using the terms "renal denervation", "resistant hypertension" and "external ultrasound" was performed using PubMed, and references retrieved were selected based on relevancy and year of publication (date range 1991-2015). The Surround Sound™ system appears to be a promising approach to RDN which eliminates several of the factors currently limiting the intravenous approach. So far, it has demonstrated efficacy for reducing blood pressure in resistant hypertension patients with minimal adverse effects. Several double-blind, sham-controlled clinical trials are currently underway to confirm the validity of these findings.
Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index
ELEC, FLORIN IOAN; LUCAN, CIPRIAN; GHERVAN, LIVIU; MUNTEANU, VALENTIN; MOGA, SILVIU; SUCIU, MIHAI; ENACHE, DAN; ELEC, ALINA; MUNTEANU, ADRIANA; BARBOS, ADRIAN; IACOB, GHEORGHITA; LUCAN, MIHAI
2014-01-01
Introduction With a growing shortage of organs for transplantation, finding ways of increasing the donor organ pool remains of utmost importance. Perfusion machines (PM) have been proven to enhance the potential for kidney transplants to function sooner, last longer, giving patients the opportunity for a better life quality. Objective The aim of this study is to evaluate the relation between the resistance index provided by the PM, the postoperative resistance index measured by Doppler ultrasound and the initial graft outcome. Material and method Between January 2012-December 2012, clinical data obtained from 82 consecutive renal transplants from brain death donors (BDD) which underwent PM maintenance were analyzed in a transversal study. Prior transplantation we recorded the solution temperature, filtration rate and the resistance index provided by PM. After the surgical intervention, each patient had standard follow-up. Doppler ultrasound resistivity index (RI) was recorded on the first postoperative day. Results Out of 115 renal transplants, 98 (85.21%) were performed with grafts from BDD. The PM was used for 82 renal grafts. The Doppler resistance index in relation to the resistance index shows a highly statistical correlation by linear regression (R=0.813, p<0.0001). Primary graft function was recorded in 74 patients (90.24%) and it was highly statistically significant correlated with the resistance index measured by PM. Out of 8 patients with primary non-function, 6 patients recovered with normal graft function at one year. Conclusion The resistivity index recorded by the life-port machine is correlated with the vascular resistivity index measured by Doppler ultrasound and thus it may predicts the primary graft outcome. PMID:26527992
NASA Astrophysics Data System (ADS)
Rieck, Birgit; Curiel, Laura; Mougenot, Charles; Zhang, Kunyan; Pichardo, Samuel
2012-11-01
Background. In the present work we study the therapeutic effect of focused ultrasound on localized abscess induced by methicillin-resistant Staphylococcus aureus (MRSA). MRSA is a major nosocomial pathogen in health-care facilities. The people, particularly those who are immunocompromised are prone to develop infectious sites that often are non-responsive to regular treatments. Because of its capability to induce a rise of temperature at a very precise location, the use of focused ultrasound represents a considerable opportunity to propose a new therapy for MRSA-related infections. Methods. A 50μL subcutaneous injection of MRSA strain USA 400 bacteria at a concentration of 7×103/μL was made on the left thigh of BALB/c mice and an abscess of 6±2 mm-length formed after 48hrs. A transducer operating at 3 MHz with a focal length of 50mm and diameter of 32mm was used to treat the abscess. The focal point was positioned 2mm under the skin at the abscess center. Forty-eight hours after injection 4 ultrasound exposures of 9s-each were applied to each abscess under Magnetic Resonance-guidance. Each exposure was followed by a 1 min pause. Real-time estimation of change of temperature was done using a communication toolbox (matMRI) developed in our laboratory. Three experimental groups of 6 animals each were tested: moderate temperature (MT), high temperature (HT) and control. MT and HT groups reached, respectively, 55°C and 65°C at end of exposure. Effectiveness of the treatment was assessed by culturing bacteria of the treated abscess 1 and 4 days after treatment. Spleen samples were cultured to test for septicemia. Results. Macroscopic evaluation of treated abscess indicated a diminution of external size of abscess 1d after treatment. Treatment did not cause open wounds. Bacteria counting 1 day after treatment was 0.7±1.1 × 105, 0.5±0.7 × 105 and 1.1±2.3 × 105 CFU/μl for MT, HT and control groups, respectively; for the 4-day end point, the count was 0.6±0.6 × 104, 0.09±0.2×104 and 1.0±1.3 × 104. Absence of bacteria in spleen samples indicated that the therapy did not trigger septicemia. Conclusions. Focused ultrasound induces a therapeutic effect in abscesses induced by MRSA. This effect is observed as a reduction of the number bacteria in the abscess. These initial results indicate that focused ultrasound is a viable option for the treatment of MRSA-related infections.
Fananapazir, Ghaneh; Rao, Rajiv; Corwin, Michael T; Naderi, Sima; Santhanakrishnan, Chandrasekar; Troppmann, Christoph
2015-10-01
The purpose of this study was to assess the sensitivity of ultrasound in evaluating peritransplant hematomas that require surgical evacuation in recipients of kidney transplants. Thirty-four patients who underwent 37 hematoma evacuations underwent ultrasound examinations in the 24 hours before surgical evacuation. The operative reports were evaluated for presence and size of collection, presence of active bleeding at operation, and composition of the hematoma. The clinical findings leading to the ultrasound examination were recorded. Ultrasound examinations were evaluated in consensus by two board-certified and fellowship-trained abdominal radiologists for the presence, size, and echogenicity of the collection; subjective perfusion visualized with color and power Doppler ultrasound; velocities of the renal arteries; and arcuate artery resistive indexes. Ten of the 37 imaged hematomas (27%) had either no or small (< 50 mL) fluid collections on ultrasound examination. With sonographic volumetry, the reported intraoperative volumes were underestimated by 46%. The mean arcuate artery resistive index was 0.82 in the superior pole, 0.81 in the mid pole, and 0.78 in the inferior pole of the kidney. A decrease in hemoglobin level was the most sensitive clinical finding for determining the presence of perigraft hematomas. Our results suggest that gray-scale sonography alone appears to have limited sensitivity in detecting clinically significant peritransplant hematomas and that its use may result in overall underestimates of hematomas.
Ultrasound in regional anaesthesia.
Griffin, J; Nicholls, B
2010-04-01
Ultrasound guidance is rapidly becoming the gold standard for regional anaesthesia. There is an ever growing weight of evidence, matched with improving technology, to show that the use of ultrasound has significant benefits over conventional techniques, such as nerve stimulation and loss of resistance. The improved safety and efficacy that ultrasound brings to regional anaesthesia will help promote its use and realise the benefits that regional anaesthesia has over general anaesthesia, such as decreased morbidity and mortality, superior postoperative analgesia, cost-effectiveness, decreased postoperative complications and an improved postoperative course. In this review we consider the evidence behind the improved safety and efficacy of ultrasound-guided regional anaesthesia, before discussing its use in pain medicine, paediatrics and in the facilitation of neuraxial blockade. The Achilles' heel of ultrasound-guided regional anaesthesia is that anaesthetists are far more familiar with providing general anaesthesia, which in most cases requires skills that are achieved faster and more reliably. To this ends we go on to provide practical advice on ultrasound-guided techniques and the introduction of ultrasound into a department.
NASA Astrophysics Data System (ADS)
Solovov, V. A.; Dvoynikov, S. Y.; Vozdvizhenskiy, M. O.
2011-09-01
Introduction & Objectives: High-Intensity Focused Ultrasound (HIFU) has been shown to be a successful treatment for localised prostate cancer (PC). Here we have explored the effectiveness of the HIFU treatment for hormone-resistant prostate cancer (HRPC). Materials & Methods: 341 patients were treated in our center between September 2007 and December 2009; all of them showed treatment failure following hormone ablation. The median time before hormone-resistance was 20 (3-48) months. In the group with localised PC: number of patients 237, Gleason score ≤7, stage T1-2N0M0, age 69 (60-89) years, mean PSA before treatment 40,0 (5,8-92,9) ng/ml, mean prostate volume—39,3 (28-92) cc; in the group with locally advanced PC: number of patients 104, Gleason score ≤9, stage T2-3N0M0, age 72 (52-83) years, PSA before treatment 30,3 (20,1-60) ng/ml, mean prostate volume—41,2 (25-198) cc. HIFU was delivered under spinal anesthesia using the Ablatherm HIFU device (EDAP, France). Pre HIFU transurethral resection of the prostate (TURP) was performed for all patients. Mean follow-up time 18 months (3-30). Results: The median PSA level 12 months after HIFU treatment was 0,04 (0-2,24) ng/ml—localised PC, and for locally advanced disease—0,05 (0-48,4) ng/ml, at 18 months after HIFU treatment this was 0,2 (0,02-2,0) ng/ml for localised PC, and for locally advanced disease 0,18 (0,04-7,45) ng/ml. Patients with localised PC has 4,5% recurrence, those with locally advanced PC 20%. Kaplan-Meir analyses of the total group indicated that the risk of recurrence after 1 year follow-up was 10%, the risk of recurrence was 19% after 2 years of follow-up. Conclusions: Our initial experience shows that ultrasound ablation is safe, minimally invasive and effective as a treatment for localised and locally advanced hormone-resistant prostate cancer.
Chen, Hung-Yuan; Lin, Chien-Chu; Chiu, Yen-Ling; Hsu, Shih-Ping; Pai, Mei-Fen; Yang, Ju-Yeh; Wu, Hon-Yen; Peng, Yu-Sen
2014-01-01
The liver fat contents and abdominal adiposity correlate well with insulin resistance (IR) in the general population. However, the relationship between liver fat content, abdominal adiposity and IR in non-diabetic hemodialysis (HD) patients remains unclear. This study aimed to clarify the associations among these factors. This is a cross-sectional, observational study. All patients received abdominal ultrasound for liver fat content. Abdominal adiposity was quantified with the conicity index (Ci) and waist circumference (WC). We checked the homeostasis model assessment for insulin resistance index (HOMA-IR) for IR. A total of 112 patients (60 women) were analyzed. Subjects with higher liver fat contents and WC had higher IR indices. But Ci did not correlate with IR indices. In both the multi-variable linear regression model and the logistic regression model, only higher liver fat content predicted a severe IR status. Liver fat contents have a remarkable correlation with IR; however, abdominal adiposity, measured either by Ci or WC, dose not independently correlate with IR in non-diabetic prevalent HD patients. © 2014 S. Karger AG, Basel.
Sikdar, Siddhartha; Shah, Jay P.; Gebreab, Tadesse; Yen, Ru-Huey; Gilliams, Elizabeth; Danoff, Jerome; Gerber, Lynn H.
2009-01-01
Objective Apply ultrasound (US) imaging techniques to better describe the characteristics of myofascial trigger points (MTrPs) and the immediately adjacent soft tissue. Design Descriptive (exploratory) study. Setting Biomedical research center. Participants 9 subjects meeting Travell and Simons’s criteria for MTrPs in a taut band in the upper trapezius. Interventions (None) Main Outcome Measures MTrPs were evaluated by 1) physical examination, 2) pressure algometry, and 3) three types of ultrasound imaging including grayscale (2D US), vibration sonoelastography (VSE), and Doppler. Methods Four sites in each patient were labeled based on physical examination as either active MTrP (spontaneously-painful, A-MTrP), latent MTrP (non-painful, L-MTrP), or normal myofascial tissue. US examination was performed on each subject by a team blinded to the physical findings. A 12-5 MHz US transducer was used. VSE was performed by color Doppler variance imaging while simultaneously inducing vibrations (~92Hz) with a handheld massage vibrator. Each site was assigned a tissue imaging score (TIS) as follows: 0 = uniform echogenicity and stiffness; 1 = focal hypoechoic region with stiff nodule; 2 = multiple hypoechoic regions with stiff nodules. Blood flow in the neighborhood of MTrPs was assessed using Doppler imaging. Each site was assigned a blood flow waveform score (BFS) as follows: 0 = normal arterial flow in muscle; 1 = elevated diastolic flow; 2 = high-resistance flow waveform with retrograde diastolic flow. Results MTrPs appeared as focal, hypoechoic regions on 2D US, indicating local changes in tissue echogenicity, and as focal regions of reduced vibration amplitude on VSE, indicating a localized stiff nodule. MTrPs were elliptical in shape, with a size of 0.16 ± 0.11 cm2. There were no significant differences in size between A-MTrPs and L-MTrPs. Sites containing MTrPs were more likely to have higher TIS compared to normal myofascial tissue (p<0.002). Small arteries (or enlarged arterioles) near A-MTrPs showed retrograde flow in diastole indicating a highly resistive vascular bed. A-MTrP sites were more likely to have higher BFS compared to L-MTrPs (p<0.021). Conclusions Preliminary findings show that, under the conditions of this investigation, US imaging techniques can be used to distinguish myofascial tissue containing MTrPs from normal myofascial tissue (lacking trigger points). Ultrasound enables visualization and some characterization of MTrPs and adjacent soft tissue. PMID:19887205
Ultrasound-enhanced localized chemotherapy of drug-sensitive and multidrug resistant tumors
NASA Astrophysics Data System (ADS)
Rapoport, Natalya Y.; Gao, Zhonggao; Kamaev, Pavel; Christensen, Douglas A.
2006-05-01
A new modality of targeted tumor chemotherapy is based on the drug encapsulation in polymeric nanoparticles followed by a localized release at the tumor site triggered by focused ultrasound. Effect of 1 MHz and 3 MHz unfocused ultrasound applied locally to the tumor on the Doxorubicin (DOX) biodistribution and tumor growth rates was measured for ovarian carcinoma tumors in nu/nu mice. The bioeffects of ultrasound were investigated on the systemic and cellular levels. Growth rates of A2780 ovarian carcinoma tumors were substantially reduced by combining micellar drug delivery with tumor irradiation. Ultrasound effect was not thermal as manifested by intratumoral temperature measurements during sonication. Biodistribution studies showed that ultrasound did not enhance micelle extravasation. Main mechanisms of the ultrasound-enhanced chemotherapy included (i) passive targeting of drug-loaded micelles to the tumor interstitium; (ii) ultrasound-triggered localized drug release from micelles in the tumor volume; (iii) enhanced micelle and drug diffusion through the tumor interstitium; and (iv) ultrasound-triggered cell membrane damage resulting in the enhanced micelle and drug uptake by tumor cells.
Selective intracellular vaporisation of antibody-conjugated phase-change nano-droplets in vitro
NASA Astrophysics Data System (ADS)
Ishijima, A.; Minamihata, K.; Yamaguchi, S.; Yamahira, S.; Ichikawa, R.; Kobayashi, E.; Iijima, M.; Shibasaki, Y.; Azuma, T.; Nagamune, T.; Sakuma, I.
2017-03-01
While chemotherapy is a major mode of cancer therapeutics, its efficacy is limited by systemic toxicities and drug resistance. Recent advances in nanomedicine provide the opportunity to reduce systemic toxicities. However, drug resistance remains a major challenge in cancer treatment research. Here we developed a nanomedicine composed of a phase-change nano-droplet (PCND) and an anti-cancer antibody (9E5), proposing the concept of ultrasound cancer therapy with intracellular vaporisation. PCND is a liquid perfluorocarbon nanoparticle with a liquid-gas phase that is transformable upon exposure to ultrasound. 9E5 is a monoclonal antibody targeting epiregulin (EREG). We found that 9E5-conjugated PCNDs are selectively internalised into targeted cancer cells and kill the cells dynamically by ultrasound-induced intracellular vaporisation. In vitro experiments show that 9E5-conjugated PCND targets 97.8% of high-EREG-expressing cancer cells and kills 57% of those targeted upon exposure to ultrasound. Furthermore, direct observation of the intracellular vaporisation process revealed the significant morphological alterations of cells and the release of intracellular contents.
[Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].
Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia
2012-01-01
Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rieck, Birgit; Bates, David; Pichardo, Samuel, E-mail: spichard@lakeheadu.ca, E-mail: lcuriel@lakeheadu.ca
Purpose: To study the therapeutic effect of focused ultrasound on abscesses induced by methicillin-resistantStaphylococcus aureus (MRSA). MRSA is a major nosocomial pathogen where immunocompromised patients are prone to develop infections that are less and less responsive to regular treatments. Because of its capability to induce a rise of temperature at a very precise location, the use of focused ultrasound represents a considerable opportunity for therapy of localized MRSA-related infections. Methods: 50μl of MRSA strain USA400 bacteria suspension at a concentration of 1.32 ± 0.5 × 10{sup 5} colony forming units (cfu)/μl was injected subcutaneously in the left flank of BALB/cmore » mice. An abscess of 6 ± 2 mm in diameter formed after 48 h. A transducer operating at 3 MHz with a focal length of 50 mm and diameter of 32 mm was used to treat the abscess. The focal point was positioned 2 mm under the skin at the abscess center. Forty-eight hours after injection four ultrasound exposures of 9 s each were applied to each abscess under magnetic resonance imaging guidance. Each exposure was followed by a 1 min pause. These parameters were based on preliminary experiments to ensure repetitive accurate heating of the abscess. Real-time estimation of change of temperature was done using water-proton resonance frequency and a communication toolbox (matMRI) developed inhouse. Three experimental groups of animals each were tested: control, moderate temperature (MT), and high temperature (HT). MT and HT groups reached, respectively, 52.3 ± 5.1 and 63.8 ± 7.5 °C at the end of exposure. Effectiveness of the treatment was assessed by evaluating the bacteria amount of the treated abscess 1 and 4 days after treatment. Myeloperoxidase (MPO) assay evaluating the neutrophil amount was performed to assess the local neutrophil recruitment and the white blood cell count was used to evaluate the systemic inflammatory response after focused ultrasound treatment. Results: Macroscopic evaluation of treated abscess indicated a diminution of external size of abscess 1 day after treatment. Treatment did not cause open wounds. The median (lower to upper quartile) bacterial count 1 day after treatment was 6.18 × 10{sup 3} (0.76 × 10{sup 3}–11.18 × 10{sup 3}), 2.86 × 10{sup 3} (1.22 × 10{sup 3}–7.07 × 10{sup 3}), and 3.52 × 10{sup 3} (1.18 × 10{sup 3}–6.72 × 10{sup 3}) cfu/100 μl for control, MT and HT groups, respectively; for the 4-day end point, the count was 1.37 × 10{sup 3} (0.67 × 10{sup 3}–2.89 × 10{sup 3}), 1.35 × 10{sup 3} (0.09 × 10{sup 3}–2.96 × 10{sup 3}), and 0.07 × 10{sup 3} (0.03 × 10{sup 3}–0.36 × 10{sup 3}) cfu/100 μl for control, MT and HT, showing a significant reduction (p = 0.002) on the bacterial load four days after focused ultrasound treatment when treating at high temperature (HT). The MPO amount remained unchanged between groups and days, indicating no change on local neutrophil recruitment in the abscess caused by the treatment. The white blood cell count remained unchanged between groups and days indicating that no systemic inflammatory response was caused by the treatment. Conclusions: Focused ultrasound induces a therapeutic effect in abscesses induced by MRSA. This effect is observed as a reduction of the number bacteria without significantly altering the amount of MPO at the site of a MRSA-induced abscess. These initial results suggest that focused ultrasound is a viable option for the treatment of localized MRSA-related infections.« less
Ovarian volume and gluco-insulinaemic markers in the diagnosis of PCOS during adolescence.
Villa, Paola; Rossodivita, Aurora; Sagnella, Francesca; Moruzzi, Maria Cristina; Mariano, Nicoletta; Lassandro, Anna Pia; Pontecorvi, Alfredo; Scambia, Giovanni; Lanzone, Antonio
2013-02-01
To evaluate the role of mean ovarian volume (MOV) in the diagnosis of polycystic ovary syndrome (PCOS) during adolescence, and its relationship with metabolic and endocrine parameters. Observational study. A total of 134 young girls, including 86 adolescents with PCOS and 48 controls, were studied. During the early follicular phase, a pelvic ultrasound examination was performed to measure the ovarian volume of both ovaries and to calculate the MOV. All subjects underwent hormonal assessment and an ultrasound examination. PCOS subjects were submitted to an oral glucose tolerance test. The homeostasis model assessment for insulin resistance (HOMA-IR) and several insulin resistance indexes were also determined. Androgens, free androgen index (FAI), LH and insulin resistance indexes were higher in the PCOS group. MOV was significantly different between the two groups: control group 4·6 ± 1·9 cm(3) , adolescent PCOS group 9·6 ± 4·4 cm(3) . The MOV threshold of 5·596 cm(3) offered the best compromise between sensitivity and specificity based on the characteristics of the operating receiver curve analysis. Therefore, an ovarian volume higher than 5·6 increased the risk of PCOS by about 15 times (OR 16·25 IC 95% 6·3-41·3). In adolescent PCOS girls, the ovarian volume was significantly associated with circulating testosterone and insulin, and indices of insulin resistance. During early adolescence MOV evaluation may offer an effective means to screen and follow up young girls with irregular cycles in order to prevent the long-term metabolic disturbances of the polycystic ovary syndrome. © 2012 Blackwell Publishing Ltd.
Sivakumar, Venkatasubramanian; Swaminathan, Gopalaraman; Rao, Paruchuri Gangadhar; Muralidharan, Chellappa; Mandal, Asit Baran; Ramasami, Thirumalachari
2010-08-01
Influence of ultrasound (US) on various unit operations in leather processing has been studied with the aim to improve the process efficiency, quality, reduce process time and achieve near-zero discharge levels in effluent streams as a cleaner option. Effect of US on substrate (skin/leather) matrix as well as substances used in different unit operations have been studied and found to be useful in the processing. Absorption of US energy by leather in process vessel at different distances from US source has been measured and found to be significant. Effect of particle-size of different substances due to sonication indicates positive influence on the diffusion through the matrix. Our experimental results suggest that US effect is better realized for the cases with pronounced diffusion hindrance. Influence of US on bioprocessing of leather has been studied and found beneficial. Attempts have also been made to improve the US aided processing using external aids. Operating US in pulse mode operation could be useful in order to reduce the electrical energy consumption. Use of US has also been studied in the preparation of leather auxiliaries involving mass-transfer resistance. Preliminary cost analysis carried out for ultrasound-assisted leather-dyeing process indicates scale-up possibility. Therefore, US application provide improvement in process efficiency as well as making cleaner production methods feasible. Hence, overall results suggest that use of US in leather industry is imminent and potential viable option in near future. Copyright 2009 Elsevier B.V. All rights reserved.
Ávila-Orta, Carlos A.; Quiñones-Jurado, Zoe V.; Waldo-Mendoza, Miguel A.; Rivera-Paz, Erika A.; Cruz-Delgado, Víctor J.; Mata-Padilla, José M.; González-Morones, Pablo; Ziolo, Ronald F.
2015-01-01
Isotactic polypropylenes (iPP) with different melt flow indexes (MFI) were used to fabricate nanocomposites (NCs) with 10 wt % loadings of multi-wall carbon nanotubes (MWCNTs) using ultrasound-assisted extrusion methods to determine their effect on the morphology, melt flow, and electrical properties of the NCs. Three different types of iPPs were used with MFIs of 2.5, 34 and 1200 g/10 min. Four different NC fabrication methods based on melt extrusion were used. In the first method melt extrusion fabrication without ultrasound assistance was used. In the second and third methods, an ultrasound probe attached to a hot chamber located at the exit of the die was used to subject the sample to fixed frequency and variable frequency, respectively. The fourth method is similar to the first method, with the difference being that the carbon nanotubes were treated in a fluidized air-bed with an ultrasound probe before being used in the fabrication of the NCs with no ultrasound assistance during extrusion. The samples were characterized by MFI, Optical microscopy (OM), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM), electrical surface resistivity, and electric charge. MFI decreases in all cases with addition of MWCNTs with the largest decrease observed for samples with the highest MFI. The surface resistivity, which ranged from 1013 to 105 Ω/sq, and electric charge, were observed to depend on the ultrasound-assisted fabrication method as well as on the melt flow index of the iPP. A relationship between agglomerate size and area ratio with electric charge was found. Several trends in the overall data were identified and are discussed in terms of MFI and the different fabrication methods. PMID:28793686
[Ultrasonography in acute pelvic pain].
Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim
2002-01-01
Acute pelvic pain may be the manifestation of various gynecologic and non-gynecologic disorders from less alarming rupture of the follicular cyst to life threatening conditions such as rupture of ectopic pregnancy or perforation of inflamed appendix. In order to construct an algorithm for differential diagnosis we divide acute pelvic pain into gynecologic and non-gynecologic etiology, which is than subdivided into gastrointestinal and urinary causes. Appendicitis is the most common surgical emergency and should always be considered in differential diagnosis if appendix has not been removed. Apart of clinical examination and laboratory tests, an ultrasound examination is sensitive up to 90% and specific up to 95% if graded compression technique is used. Still it is user-depended and requires considerable experience in order to perform it reliably. Meckel's diverticulitis, acute terminal ileitis, mesenteric lymphadenitis and functional bowel disease are conditions that should be differentiated from other causes of low abdominal pain by clinical presentation, laboratory and imaging tests. Dilatation of renal pelvis and ureter are typical signs of obstructive uropathy and may be efficiently detected by ultrasound. Additional thinning of renal parenchyma suggests long-term obstructive uropathy. Ruptured ectopic pregnancy, salpingitis and hemorrhagic ovarian cysts are three most commonly diagnosed gynecologic conditions presenting as an acute abdomen. Degenerating leiomyomas and adnexal torsion occur less frequently. For better systematization, gynecologic causes of acute pelvic pain could be divided into conditions with negative pregnancy test and conditions with positive pregnancy test. Pelvic inflammatory disease may be ultrasonically presented with numerous signs such as thickening of the tubal wall, incomplete septa within the dilated tube, demonstration of hyperechoic mural nodules, free fluid in the "cul-de-sac" etc. Color Doppler ultrasound contributes to more accurate diagnosis of this entity since it enables differentiation between acute and chronic stages based on analysis of the vascular resistance. Hemorrhagic ovarian cysts may be presented by variety of ultrasound findings since intracystic echoes depend upon the quality and quantity of the blood clots. Color Doppler investigation demonstrates moderate to low vascular resistance typical of luteal flow. Leiomyomas undergoing degenerative changes are another cause of acute pelvic pain commonly present in patients of reproductive age. Color flow detects regularly separated vessels at the periphery of the leiomyoma, which exhibit moderate vascular resistance. Although the classic symptom of endometriosis is chronic pelvic pain, in some patients acute pelvic pain does occur. Most of these patients demonstrate an endometrioma or "chocolate" cyst containing diffuse carpet-like echoes. Sometimes, solid components may indicate even ovarian malignancy, but if color Doppler ultrasound is applied it is less likely to obtain false positive results. One should be aware that pericystic and/or hillar type of ovarian endometrioma vascularization facilitate correct recognition of this entity. Pelvic congestion syndrome is another condition that can cause an attack of acute pelvic pain. It is usually consequence of dilatation of venous plexuses, arteries or both systems. By switching color Doppler gynecologist can differentiate pelvic congestion syndrome from multilocular cysts, pelvic inflammatory disease or adenomyosis. Ovarian vein thrombosis is a potentially fatal disorder occurring most often in the early postpartal period. Hypercoagulability, infection and stasis are main etiologic factors, and transvaginal color Doppler ultrasound is an excellent diagnostic tool to diagnose it. Acute pelvic pain may occur even in normal intrauterine pregnancy. This may be explained by hormonal changes, rapid growth of the uterus and increased blood flow. Ultrasound is mandatory for distinguishing normal intrauterine pregnancy from threatened or spontaneous abortion, ectopic pregnancy and other complications that may occur in patients with positive pregnancy test. Incomplete abortion is visualized as thickened and irregular endometrial echo with certain amount of intracavitary fluid. If applied, color Doppler ultrasound reveals low vascular resistance signals in richly perfused intracavitary area. Transvaginal sonography has high sensitivity and specificity in visualization of uterine and adnexal signs of ectopic pregnancy. Color Doppler examination may aid in detection of the peritrophoblastic flow. Furthermore, it facilitates detection of ectopic living embryo, tubal ring or unspecific adnexal tumor. Corpus luteum cysts and leiomyomas are another cause of pelvic pain during pregnancy, which can be correctly diagnosed by ultrasound. Detection of uterine dehiscence and rupture in patients with history of prior surgical intervention on uterine wall relies exclusively on correct ultrasound diagnosis. In patients with placental abruption sonographer detects hypoechoic complex representing either retroplacental hematoma, subchorionic hematoma or subamniotic hemorrhage. In closing, ultrasound has already become important and easily available tool which can efficiently recognize patients with possibly threatening conditions of different origins.
USDA-ARS?s Scientific Manuscript database
In three separate studies (156 pigs total), DXA, BIA, and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body l...
EFSUMB guidelines 2011: comment on emergent indications and visions.
Dietrich, C F; Cui, X W; Barreiros, A P; Hocke, M; Ignee, A
2012-07-01
The focus of this article is the emergent and potential indications of contrast-enhanced ultrasound (CEUS). Emergent applications of CEUS techniques include extravascular and intracavitary contrast-enhanced ultrasound, quantitative assessment of microvascular circulation for tumor response assessment, and tumor characterization using dynamic contrast-enhanced ultrasound (DCE-US). Potential indications for microbubble agents include novel molecular imaging and drug and gene delivery techniques, which have been successfully tested in animal models. "Comments and Illustrations of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Non-Liver Guidelines 2011" which focus more on established applications are published in the same supplement to Ultraschall in der Medizin (European Journal of Ultrasound). © Georg Thieme Verlag KG Stuttgart · New York.
de Souza, Marco Aurélio Martins; de Souza, Bruno Martins; Geber, Selmo
2012-03-01
The aim of this study was to evaluate the effect of tibolone on vascular resistance of the central retinal and ophthalmic artery in postmenopausal women and to compare this effect with that of placebo using transorbital ultrasound with Doppler velocimetry. We performed a prospective randomized, double-blinded, placebo-controlled study. A total of 100 healthy postmenopausal women (follicle-stimulating hormone, >40 IU/L) younger than 65 years were studied. The participants were randomly allocated to two groups: placebo (n = 50) and tibolone (2.5 mg; n = 50). Transorbital Doppler velocimetric ultrasound was performed before treatment and 80 days after. The mean age was similar in both groups. Participants who received tibolone did not show any difference in pulsatility index, resistance index, and systole/diastole ratio of the central retinal and ophthalmic arteries after treatment. The same was observed in participants who received placebo. Our study demonstrates that tibolone administration to healthy postmenopausal women does not affect the resistance of small-caliber cerebral arteries.
Fiber-Laser-Based Ultrasound Sensor for Photoacoustic Imaging
Liang, Yizhi; Jin, Long; Wang, Lidai; Bai, Xue; Cheng, Linghao; Guan, Bai-Ou
2017-01-01
Photoacoustic imaging, especially for intravascular and endoscopic applications, requires ultrasound probes with miniature size and high sensitivity. In this paper, we present a new photoacoustic sensor based on a small-sized fiber laser. Incident ultrasound waves exert pressures on the optical fiber laser and induce harmonic vibrations of the fiber, which is detected by the frequency shift of the beating signal between the two orthogonal polarization modes in the fiber laser. This ultrasound sensor presents a noise-equivalent pressure of 40 Pa over a 50-MHz bandwidth. We demonstrate this new ultrasound sensor on an optical-resolution photoacoustic microscope. The axial and lateral resolutions are 48 μm and 3.3 μm. The field of view is up to 1.57 mm2. The sensor exhibits strong resistance to environmental perturbations, such as temperature changes, due to common-mode cancellation between the two orthogonal modes. The present fiber laser ultrasound sensor offers a new tool for all-optical photoacoustic imaging. PMID:28098201
RI in central retinal artery as assessed by CDI does not correspond to retinal vascular resistance.
Polska, E; Kircher, K; Ehrlich, P; Vecsei, P V; Schmetterer, L
2001-04-01
The aim of the present study was to investigate the association between ultrasound Doppler measurements of resistive index (RI) in the central retinal artery and retinal vascular resistance (R) assessed with laser Doppler velocimetry, vessel size measurement, and calculation of ocular perfusion pressure (PP) in healthy subjects. An increase in vascular resistance was induced by inhalation of 100% O(2). During hyperoxia no significant changes in PP were observed. Mean flow velocity in main retinal veins was reduced by -27.5 +/- 2.0%. The average decrease in diameter was -11.5 +/- 1.0%. R, which was calculated as the ratio of PP to flow rate, increased by 97.6 +/- 7.7%. RI increased as well, but the effect was much smaller (6.6 +/- 2.2%). In addition, a negative correlation was found between baseline values of R and RI (r = -0.83). During hyperoxia R and RI were not associated. In conclusion, our data indicate that RI as assessed with color Doppler imaging in the central retinal artery is not an adequate measure of R.
Yang, Hong; Deng, Liwei; Li, Tingting; Shen, Xue; Yan, Jie; Zuo, Liangming; Wu, Chunhui; Liu, Yiyao
2015-12-01
Multidrug resistance (MDR) is a major impediment to the success of cancer chemotherapy. One of the effective approaches to overcome MDR is to use nanoparticle-mediated the gene silence of chemotherapeutic export proteins by RNA interference to increase drug accumulation in drug resistant cancer cells. In this work, a new co-delivery system, DOX-PLGA/PEI/P-gp shRNA nanobubbles (NBs) around 327 nm, to overcome doxorubicin (DOX) resistance in MCF-7 human breast cancer was designed and developed. Positively charged polyethylenimine (PEI) were modified onto the surface of DOX-PLGA NBs through DCC/NHS crosslinking, and could efficiently condense P-gp shRNA into DOX-PLGA/PEI NBs at vector/shRNA weight ratios of 70:1 and above. An in vitro release profile demonstrated an efficient DOX release (more than 80%) from DOX-PLGA/PEI NBs at pH 4.4, suggesting a pH-responsive drug release for the multifunctionalized NBs. Cellular experimental results further showed that DOX-PLGA/PEI/P-gp shRNA NBs could facilitate cellular uptake of DOX into cells and increase the cell proliferation suppression effect of DOX against MCF-7/ADR cells (a DOX-resistant and P-glycoprotein (P-gp) over-expression cancer cell line). The IC50 of DOX-PLGA NBs against MCF-7/ADR cells was 2-fold lower than that of free DOX. The increased cellular uptake and nuclear accumulation of DOX delivered by DOX-PLGA/PEI/P-gp shRNA NBs in MCF-7/ADR cells was confirmed by fluorescence microscopy and fluorescence spectrophotometry, and might be owning to the down-regulation of P-gp and reduced the efflux of DOX. The cellular uptake mechanism of DOX-PLGA/PEI/P-gp shRNA NBs indicated that the macropinocytosis was one of the pathways for the uptake of NBs by MCF-7/ADR cells, which was also an energy-dependent process. Furthermore, the in vitro cellular ultrasound imaging suggested that the employment of the DOX-PLGA/PEI/P-gp shRNA NBs could efficiently enhance ultrasound imaging of cancer cells. These results demonstrated that the developed DOX-PLGA/PEI/P-gp shRNA NBs is a potential, safe and efficient theranotic agent for cancer therapy and diagnostics.
Echocardiography in the flight program
NASA Technical Reports Server (NTRS)
Charles, John B.; Bungo, Michael W.; Mulvagh, Sharon L.
1991-01-01
Observations on American and Soviet astronauts have documented the association of changes in cardiovascular function during orthostasis with space flight. A basic understanding of the cardiovascular changes occurring in astronauts requires the determination of cardiac output and total peripheral vascular resistance as a minimum. In 1982, we selected ultrasound echocardiography as our means of acquiring this information. Ultrasound offers a quick, non-invasive and accurate means of determining stroke volume which, when combined with the blood pressure and heart rate measurements of the stand test, allows calculation of changes in peripheral vascular resistance, the body's major response to orthostatic stress. The history of echocardiography in the Space Shuttle Program is discussed and the results are briefly presented.
Sun, Jianxia; Mei, Zhouxiong; Tang, Yajuan; Ding, Lijun; Jiang, Guichuan; Zhang, Chi; Sun, Aidong; Bai, Weibin
2016-08-24
As an alternative preservation method to thermal treatment, ultrasound is a novel non-thermal processing technology that can significantly avoid undesirable nutritional changes. However, recently literature indicated that anthocyanin degradation occurred when high amplitude ultrasound was applied to juice. This work mainly studied the effect of ultrasound on the stability and antioxidant capacity of pelargonidin-3-glucoside (Pg-3-glu) and the correlation between anthocyanin degradation and •OH generation in a simulated system. Results indicated that the spectral intensities of Pg-3-glu decreased with increasing ultrasound power (200-500 W) and treatment time (0-60 min). The degradation trend was consistent with first-order reaction kinetics (R² > 0.9100). Further study showed that there was a good linear correlation between Pg-3-glu degradation and •OH production (R² = 0.8790), which indicated the important role of •OH in the degradation of anthocyanin during ultrasound exposure. Moreover, a decrease in the antioxidant activity of solution(s) containing Pg-3-glu as evaluated by the DPPH and FRAP methods was observed after ultrasound treatment.
A Six-Week Resistance Training Program Does Not Change Shear Modulus of the Triceps Brachii.
Akagi, Ryota; Shikiba, Tomofumi; Tanaka, Jun; Takahashi, Hideyuki
2016-08-01
We investigated the effect of a 6-week resistance training program on the shear modulus of the triceps brachii (TB). Twenty-three young men were randomly assigned to either the training (n = 13) or control group (n = 10). Before and after conducting the resistance training program, the shear modulus of the long head of the TB was measured at the point 70% along the length of the upper arm from the acromial process of the scapula to the lateral epicondyle of the humerus using shear wave ultrasound elastography. Muscle thickness of the long head of the TB was also determined at the same site by ultrasonography used during both tests. A resistance exercise was performed 3 days a week for 6 weeks using a dumbbell mass-adjusted to 80% of the 1-repetition maximum (1RM). The training effect on the muscle thickness and 1RM was significant. Nevertheless, the muscle shear modulus was not significantly changed after the training program. From the perspective of muscle mechanical properties, the present results indicate that significant adaptation must occur to make the TB more resistant to subsequent damaging bouts during the 6-week training program to target the TB.
Whole-Body and Hepatic Insulin Resistance in Obese Children
Ibarra-Reynoso, Lorena del Rocío; Pisarchyk, Liudmila; Pérez-Luque, Elva Leticia; Garay-Sevilla, Ma. Eugenia; Malacara, Juan Manuel
2014-01-01
Background Insulin resistance may be assessed as whole body or hepatic. Objective To study factors associated with both types of insulin resistance. Methods Cross-sectional study of 182 obese children. Somatometric measurements were registered, and the following three adiposity indexes were compared: BMI, waist-to-height ratio and visceral adiposity. Whole-body insulin resistance was evaluated using HOMA-IR, with 2.5 as the cut-off point. Hepatic insulin resistance was considered for IGFBP-1 level quartiles 1 to 3 (<6.67 ng/ml). We determined metabolite and hormone levels and performed a liver ultrasound. Results The majority, 73.1%, of obese children had whole-body insulin resistance and hepatic insulin resistance, while 7% did not have either type. HOMA-IR was negatively associated with IGFBP-1 and positively associated with BMI, triglycerides, leptin and mother's BMI. Girls had increased HOMA-IR. IGFBP-1 was negatively associated with waist-to-height ratio, age, leptin, HOMA-IR and IGF-I. We did not find HOMA-IR or IGFBP-1 associated with fatty liver. Conclusion In school-aged children, BMI is the best metric to predict whole-body insulin resistance, and waist-to-height ratio is the best predictor of hepatic insulin resistance, indicating that central obesity is important for hepatic insulin resistance. The reciprocal negative association of IGFBP-1 and HOMA-IR may represent a strong interaction of the physiological processes of both whole-body and hepatic insulin resistance. PMID:25411786
Seto, Jennifer E.; Polat, Baris E.; Lopez, Renata F.V.; Blankschtein, Daniel; Langer, Robert
2010-01-01
The simultaneous application of ultrasound and the surfactant sodium lauryl sulfate (referred to as US/SLS) to skin enhances transdermal drug delivery (TDD) in a synergistic mechanical and chemical manner. Since full-thickness skin (FTS) and split-thickness skin (STS) differ in mechanical strength, US/SLS treatment may have different effects on their transdermal transport pathways. Therefore, we evaluated STS as an alternative to the well-established US/SLS-treated FTS model for TDD studies of hydrophilic permeants. We utilized the aqueous porous pathway model to compare the effects of US/SLS treatment on the skin permeability and the pore radius of pig and human FTS and STS over a range of skin electrical resistivity values. Our findings indicate that the US/SLS-treated pig skin models exhibit similar permeabilities and pore radii, but the human skin models do not. Furthermore, the US/SLS-enhanced delivery of gold nanoparticles and quantum dots (two model hydrophilic macromolecules) is greater through pig STS than through pig FTS, due to the presence of less dermis that acts as an artificial barrier to macromolecules. In spite of greater variability in correlations between STS permeability and resistivity, our findings strongly suggest the use of 700-μm-thick pig STS to investigate the in vitro US/SLS-enhanced delivery of hydrophilic macromolecules. PMID:20346994
FE6 during Sprint Ultrasound Scans
2013-11-22
ISS038-E-007119 (21 Nov. 2013) --- Japan Aerospace Exploration Agency astronaut Koichi Wakata, Expedition 38 flight engineer, wears ultrasound gear around his legs while performing the Integrated Resistance and Aerobic Training Study (Sprint) experiment in the Columbus laboratory of the International Space Station. Sprint evaluates the use of high intensity, low volume exercise training to minimize loss of muscle, bone, and cardiovascular function in station crew members during long-duration missions.
Giampaolino, Pierluigi; Morra, Ilaria; De Rosa, Nicoletta; Cagnacci, Angelo; Pellicano, Massimiliano; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe
2017-09-01
Polycystic ovarian syndrome (PCOS) is the most common endocrine disorder in gynecology. In PCOS patients vascularization parameters are altered. Transvaginal hydrolaparoscopy (THL) is a mini-invasive approach for ovarian drilling in PCOS patients. In this study, we assessed the effect of ovarian drilling using THL on ovarian volume (OV) and vascularization index (VI) using 3D power Doppler ultrasonography in CC-resistant PCOS patients. A case-control study on 123 CC-resistant PCOS women who underwent THL ovarian drilling was performed. Patients underwent 3D ultrasound and power Doppler to measure VI, flow index (FI), vascularization flow index (VFI) and to evaluate OV before and after the procedure, at six months, and on the early follicular phase of the menstrual cycle. After THL ovarian drilling, OV and power Doppler flow indices were significantly reduced compared to pre-operative values (OV: 7.85 versus 11.72 cm 3 , p < 0.01; VI: 2.50 versus 4.81, p < 0.01; VFI: 1.10 versus 2.16, p < 0.01; FI: 32.05 versus 35.37, p < 0.01). In conclusion, THL ovarian drilling seems to reduce OV and 3D power Doppler indices, and could therefore be a viable alternative to LOD in PCOS patients resistant to medical therapy.
Dumford, Donald; Suwantarat, Nuntra; Bhasker, Vineet; Kundrapu, Sirisha; Zabarsky, Trina F; Drawz, Paul; Zhu, Hui; Donskey, Curtis J
2013-03-01
We conducted an investigation after identifying a cluster of 4 serious infections following transrectal ultrasound-guided biopsy of the prostate (TRUBP) during a 2-month period. Veterans Affairs medical center. Patients with urinary tract infection (UTI) after TRUBP and time-matched controls with no evidence of infection. The incidence of UTI within 30 days after TRUBP was calculated from 2002 through 2010. We evaluated the correlation between infection with fluoroquinolone-resistant gram-negative bacilli (GNB) and fluoroquinolone resistance in outpatient Escherichia coli urinary isolates and performed a case-control study to determine risk factors for infection with fluoroquinolone-resistant GNB. Processes for TRUBP prophylaxis, procedures, and equipment sterilization were reviewed. An outbreak of UTI due to fluoroquinolone-resistant E. coli after TRUBP began 2 years before the cluster was identified and was correlated with increasing fluoroquinolone resistance in outpatient E. coli. No deficiencies were identified in equipment processing or biopsy procedures. Fluoroquinolone-resistant E. coli UTI after TRUBP was independently associated with prior infection with fluoroquinolone-resistant GNB (adjusted odds ratio, 20.8; P=.005). A prediction rule including prior UTI, hospitalization in the past year, and previous infection with fluoroquinolone-resistant GNB identified only 17 (49%) of 35 cases. The outbreak of fluoroquinolone-resistant E. coli infections after TRUBP closely paralleled rising rates of fluoroquinolone resistance among outpatient E. coli isolates. The delayed detection of the outbreak and the absence of sensitive predictors of infection suggest that active surveillance for infection after TRUBP is necessary in the context of increasing fluoroquinolone resistance in the United States.
Ten good reasons to practice ultrasound in critical care.
Lichtenstein, Daniel; van Hooland, Simon; Elbers, Paul; Malbrain, Manu L N G
2014-01-01
Over the past decade, critical care ultrasound has gained its place in the armamentarium of monitoring tools. A greater understanding of lung, abdominal, and vascular ultrasound plus easier access to portable machines have revolutionised the bedside assessment of our ICU patients. Because ultrasound is not only a diagnostic test, but can also be seen as a component of the physical exam, it has the potential to become the stethoscope of the 21st century. Critical care ultrasound is a combination of simple protocols, with lung ultrasound being a basic application, allowing assessment of urgent diagnoses in combination with therapeutic decisions. The LUCI (Lung Ultrasound in the Critically Ill) consists of the identification of ten signs: the bat sign (pleural line); lung sliding (seashore sign); the A-lines (horizontal artefact); the quad sign and sinusoid sign indicating pleural effusion; the fractal and tissue-like sign indicating lung consolidation; the B-lines and lung rockets indicating interstitial syndromes; abolished lung sliding with the stratosphere sign suggesting pneumothorax; and the lung point indicating pneumothorax. Two more signs, the lung pulse and the dynamic air bronchogram, are used to distinguish atelectasis from pneumonia. The BLUE protocol (Bedside Lung Ultrasound in Emergency) is a fast protocol (< 3 minutes), also including a vascular (venous) analysis allowing differential diagnosis in patients with acute respiratory failure. With this protocol, it becomes possible to differentiate between pulmonary oedema, pulmonary embolism, pneumonia, chronic obstructive pulmonary disease, asthma, and pneumothorax, each showing specific ultrasound patterns and profiles. The FALLS protocol (Fluid Administration Limited by Lung Sonography) adapts the BLUE protocol to be used in patients with acute circulatory failure. It makes a sequential search for obstructive, cardiogenic, hypovolemic, and distributive shock using simple real-time echocardiography in combination with lung ultrasound, with the appearance of B-lines considered to be the endpoint for fluid therapy. An advantage of lung ultrasound is that the patient is not exposed to radiation, and so the LUCI-FLR project (LUCI favouring limitation of radiation) can be unfolded in trauma patients. Although it has been practiced for 25 years, critical care ultrasound is a relatively young but expanding discipline and can be seen as the stethoscope of the modern intensivist. In this review, the usefulness and advantages of ultrasound in the critical care setting are discussed in ten points. The emphasis is on a holistic approach, with a central role for lung ultrasound.
Nicholson, Stuart F.; Nimrod, Carl A.
1988-01-01
This article addresses the current indications for an obstetric ultrasound and describes the findings that it is reasonable to expect when reading an ultrasound report. The authors discuss several common obstetrical problems focussing the attention on the usefulness of the imaging information. Finally, they provide a glimpse into the future direction of obstetric ultrasound by discussing vaginal scanning, Doppler assessment of fetal blood flow, and routine ultrasound in pregnancy. PMID:21253229
Integrated medical school ultrasound: development of an ultrasound vertical curriculum.
Bahner, David P; Adkins, Eric J; Hughes, Daralee; Barrie, Michael; Boulger, Creagh T; Royall, Nelson A
2013-07-02
Physician-performed focused ultrasonography is a rapidly growing field with numerous clinical applications. Focused ultrasound is a clinically useful tool with relevant applications across most specialties. Ultrasound technology has outpaced the education, necessitating an early introduction to the technology within the medical education system. There are many challenges to integrating ultrasound into medical education including identifying appropriately trained faculty, access to adequate resources, and appropriate integration into existing medical education curricula. As focused ultrasonography increasingly penetrates academic and community practices, access to ultrasound equipment and trained faculty is improving. However, there has remained the major challenge of determining at which level is integrating ultrasound training within the medical training paradigm most appropriate. The Ohio State University College of Medicine has developed a novel vertical curriculum for focused ultrasonography which is concordant with the 4-year medical school curriculum. Given current evidenced-based practices, a curriculum was developed which provides medical students an exposure in focused ultrasonography. The curriculum utilizes focused ultrasonography as a teaching aid for students to gain a more thorough understanding of basic and clinical science within the medical school curriculum. The objectives of the course are to develop student understanding in indications for use, acquisition of images, interpretation of an ultrasound examination, and appropriate decision-making of ultrasound findings. Preliminary data indicate that a vertical ultrasound curriculum is a feasible and effective means of teaching focused ultrasonography. The foreseeable limitations include faculty skill level and training, initial cost of equipment, and incorporating additional information into an already saturated medical school curriculum. Focused ultrasonography is an evolving concept in medicine. It has been shown to improve education and patient care. The indications for and implementation of focused ultrasound is rapidly expanding in all levels of medicine. The ideal method for teaching ultrasound has yet to be established. The vertical curriculum in ultrasound at The Ohio State University College of Medicine is a novel evidenced-based training regimen at the medical school level which integrates ultrasound training into medical education and serves as a model for future integrated ultrasound curricula.
Evers, Stefanie; Thoreson, Andrew R; Smith, Jay; Zhao, Chunfeng; Geske, Jennifer R; Amadio, Peter C
2018-01-01
The aim of this study was to assess alterations in median nerve (MN) biomechanics within the carpal tunnel resulting from ultrasound-guided hydrodissection in a cadaveric model. Twelve fresh frozen human cadaver hands were used. MN gliding resistance was measured at baseline and posthydrodissection, by pulling the nerve proximally and then returning it to the origin. Six specimens were treated with hydrodissection, and 6 were used as controls. In the hydrodissection group there was a significant reduction in mean peak gliding resistance of 92.9 ± 34.8 mN between baseline and immediately posthydrodissection (21.4% ± 10.5%; P = 0.001). No significant reduction between baseline and the second cycle occurred in the control group: 9.6 ± 29.8 mN (0.4% ± 5.3%; P = 0.467). Hydrodissection can decrease the gliding resistance of the MN within the carpal tunnel, at least in wrists unaffected by carpal tunnel syndrome. A clinical trial of hydrodissection seems justified. Muscle Nerve 57: 25-32, 2018. © 2017 Wiley Periodicals, Inc.
Campeggi, Alexandre; Ouzaid, Idir; Xylinas, Evanguelos; Lesprit, Philippe; Hoznek, Andras; Vordos, Dimitri; Abbou, Claude-Clément; Salomon, Laurent; de la Taille, Alexandre
2014-02-01
To evaluate the incidence, and clinical and bacterial features of iatrogenic prostatitis within 1 month after transrectal ultrasound-guided biopsy for detection of prostate cancer. From January 2006 to December 2009, 3000 patients underwent a 21-core transrectal ultrasound-guided prostate biopsy at Henri Mondor Hospital (Créteil, France) and were prospectively followed. All patients had a fluoroquinolone antimicrobial prophylaxis for 7 days. The primary study end-point was to evaluate the incidence of iatrogenic acute prostatitis within 1 month after the biopsy. The secondary end-point was to analyze the clinical and the bacterial features of the prostatitis. Overall, 20 patients of the entire study population (0.67%) had an acute bacterial prostatitis within 2.90 ± 1.77 days (range 1-7 days) after the transrectal ultrasound-guided biopsy. The groups of patients with (n = 20) and without (n = 2980) infection were similar in terms of age, prostate-specific antigen level and prostate volume. Escherichia coli was the only isolated bacteria. The subsequent tests for antibiotic susceptibility showed a 95% resistance for fluroquinolone and amoxicillin. Resistance to amoxiclav, trimethoprim-sulfamethoxazole, third generation cephalosporin and amikacin was 70%, 70%, 25% and 5% respectively. No resistance to imipenem was reported. They were all admitted for treatment without the need of intensive care unit referral. Complete recovery was achieved after 21.4 ± 7 days of antibiotic treatment. A fluroquinolone-based regimen still represents an appropriate prophylaxis protocol to minimize the risk of acute prostatitis secondary to prostate biopsy. Patients should be provided the appropriate care soon after the onset of the symptoms. An intravenous third generation cephalosporin or imipenem-based therapy seem to provide satisfying results. © 2013 The Japanese Urological Association.
Ethical analysis of non-medical fetal ultrasound.
Leung, John Lai Yin; Pang, Samantha Mei Che
2009-09-01
Obstetric ultrasound is the well-recognized prenatal test used to visualize and determine the condition of a pregnant woman and her fetus. Apart from the clinical application, some businesses have started promoting the use of fetal ultrasound machines for nonmedical reasons. Non-medical fetal ultrasound (also known as 'keepsake' ultrasound) is defined as using ultrasound to view, take a picture, or determine the sex of a fetus without a medical indication. Notwithstanding the guidelines and warnings regarding ultrasound safety issued by governments and professional bodies, the absence of scientifically proven physical harm to fetuses from this procedure seems to provide these businesses with grounds for rapid expansion. However, this argument is too simplistic because current epidemiological evidence is not synchronous with advancing ultrasound technology. As non-medical fetal ultrasound has aroused very significant public attention, a thorough ethical analysis of this topic is essential. Using a multifaceted approach, we analyse the ethical perspective of non-medical fetal ultrasound in terms of the expectant mother, the fetus and health professionals. After applying four major theories of ethics and principles (the precautionary principle; theories of consequentialism and impartiality; duty-based theory; and rights-based theories), we conclude that obstetric ultrasound practice is ethically justifiable only if the indication for its use is based on medical evidence. Non-medical fetal ultrasound can be considered ethically unjustifiable. Nevertheless, the ethical analysis of this issue is time dependent owing to rapid advancements in ultrasound technology and the safety issue. The role of health professionals in ensuring that obstetric ultrasound is an ethically justifiable practice is also discussed.
Rojas, Meliza Lindsay; Trevilin, Júlia Hellmeister; Funcia, Eduardo Dos Santos; Gut, Jorge Andrey Wilhelms; Augusto, Pedro Esteves Duarte
2017-05-01
Green coconut water has unique nutritional and sensorial qualities. Despite the different technologies already studied, its enzymatic stability is still challenging. This study evaluated the use of ultrasound technology (US) for inactivating/sensitizing coconut water peroxidase (POD). The effect of both US application alone and as a pre-treatment to thermal processing was evaluated. The enzyme activity during US processing was reduced 27% after 30min (286W/L, 20kHz), demonstrating its high resistance. The thermal inactivation was described by the Weibull model under non-isothermal conditions. The enzyme became sensitized to heat after US pre-treatment. Further, the use of US resulted in more uniform heat resistance. The results suggest that US is a good technology for sensitizing enzymes before thermal processing (even for an enzyme with high thermal resistance). Therefore, the use of this technology could decrease the undesirable effects of long times and/or the high temperatures of the conventional thermal processing. Copyright © 2016 Elsevier B.V. All rights reserved.
Terefe, Netsanet Shiferaw; Buckow, Roman; Versteeg, Cornelis
2015-01-01
High-power ultrasound is a versatile technology which can potentially be used in many food processing applications including food preservation. This is part 2 of a series of review articles dealing with the effectiveness of nonthermal food processing technologies in food preservation focusing on their effect on enzymes. Typically, ultrasound treatment alone does not efficiently cause microbial or enzyme inactivation sufficient for food preservation. However, combined with mild heat with or without elevated pressure (P ≤ 500 kPa), ultrasound can effectively inactivate enzymes and microorganisms. Synergistic effects between ultrasound and mild heat have been reported for the inactivation of both enzymes and microorganisms. The application of ultrasound has been shown to enhance the rate of inactivation of quality degrading enzymes including pectin methylesterase (PME), polygalacturonase (PG), peroxidase (POD), polyphenol oxidase (PPO), and lipoxygenase (LOX) at mild temperature by up to 400 times. Moreover, ultrasound enables the inactivation of relatively heat-resistant enzymes such as tomato PG1 and thermostable orange PME at mild temperature conditions. The extent to which ultrasound enhances the inactivation rate depends on the type of enzyme, the medium in which the enzyme is suspended, and the processing condition including frequency, ultrasonic intensity, temperature, and pressure. The physical and chemical effects of cavitation are considered to be responsible for the ultrasound-induced inactivation of enzymes, although the dominant mechanism depends on the structure of the enzyme.
Vasa previa screening strategies: a decision and cost-effectiveness analysis.
Sinkey, R G; Odibo, A O
2018-05-22
The aim of this study is to perform a decision and cost-effectiveness analysis comparing four screening strategies for the antenatal diagnosis of vasa previa among singleton pregnancies. A decision-analytic model was constructed comparing vasa previa screening strategies. Published probabilities and costs were applied to four transvaginal screening scenarios which occurred at the time of mid-trimester ultrasound: no screening, ultrasound-indicated screening, screening pregnancies conceived by in vitro fertilization (IVF), and universal screening. Ultrasound-indicated screening was defined as performing a transvaginal ultrasound at the time of routine anatomy ultrasound in response to one of the following sonographic findings associated with an increased risk of vasa previa: low-lying placenta, marginal or velamentous cord insertion, or bilobed or succenturiate lobed placenta. The primary outcome was cost per quality adjusted life years (QALY) in U.S. dollars. The analysis was from a healthcare system perspective with a willingness to pay (WTP) threshold of $100,000 per QALY selected. One-way and multivariate sensitivity analyses (Monte-Carlo simulation) were performed. This decision-analytic model demonstrated that screening pregnancies conceived by IVF was the most cost-effective strategy with an incremental cost effectiveness ratio (ICER) of $29,186.50 / QALY. Ultrasound-indicated screening was the second most cost-effective with an ICER of $56,096.77 / QALY. These data were robust to all one-way and multivariate sensitivity analyses performed. Within our baseline assumptions, transvaginal ultrasound screening for vasa previa appears to be most cost-effective when performed among IVF pregnancies. However, both IVF and ultrasound-indicated screening strategies fall within contemporary willingness-to-pay thresholds, suggesting that both strategies may be appropriate to apply in clinical practice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Davidson, Brian P; Hodovan, James; Belcik, J Todd; Moccetti, Federico; Xie, Aris; Ammi, Azzdine Y; Lindner, Jonathan R
2017-05-01
Contrast-enhanced ultrasound (CEU) limb perfusion imaging is a promising approach for evaluating peripheral artery disease (PAD). However, low signal enhancement in skeletal muscle has necessitated high-power intermittent imaging algorithms, which are not clinically feasible. We hypothesized that CEU using a combination of intermediate power and a contrast agent resistant to inertial cavitation would allow real-time limb stress perfusion imaging. In normal volunteers, CEU of the calf skeletal muscle was performed on separate days with Sonazoid, Optison, or Definity. Progressive reduction in the ultrasound pulsing interval was used to assess the balance between signal enhancement and agent destruction at escalating mechanical indices (MI, 0.1-0.4). Real-time perfusion imaging at MI 0.1-0.4 using postdestructive replenishment kinetics was performed at rest and during 25 W plantar flexion contractile exercise. For Optison, limb perfusion imaging was unreliable at rest due to very low signal enhancement generated at all MIs and was possible during exercise-induced hyperemia only at MI 0.1 due to agent destruction at higher MIs. For Definity, signal intensity progressively increased with MI but was offset by microbubble destruction, which resulted in modest signal enhancement during CEU perfusion imaging and distortion of replenishment curves at MI ≥ 0.2. For Sonazoid, there strong signal enhancement at MI ≥ 0.2, with little destruction detected only at MI 0.4. Accordingly, high signal intensity and nondistorted perfusion imaging was possible at MI 0.2-0.3 and detected an 8.0- ± 5.7-fold flow reserve. Rest-stress limb perfusion imaging in humans with real-time CEU, which requires only seconds to perform, is possible using microbubbles with viscoelastic properties that produce strong nonlinear signal generation without destruction at intermediate acoustic pressures. Copyright © 2016 American Society of Echocardiography. All rights reserved.
Ultrasound-guided synovial biopsy
Sitt, Jacqueline C M; Wong, Priscilla
2016-01-01
Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578
Mohamed, Hassan R; Abdel-Azziz, Mohamed Yaqoot; Zalata, Kkaled Refaat; Abdel-Razik, Ahmed M M
2009-01-01
Background: Hepatitis C virus (HCV) infection can predispose to the development of insulin resistance before diabetes occurs. Such a potential link is particularly cogent in light of recent data indicate that diabetes may be associated with increased hepatic fibrosis progression in patients with chronic HCV infection. The aim of the study is to determine the prevalence of insulin resistance in non diabetic patients with chronic hepatitis C and its relation to liver fibrosis. Methods: Thirty eight patients with chronic liver diseases. They subdivided into 2 groups; chronic hepatitis C (CHC) with elevated liver enzymes and CHC with normal liver enzymes. Age and sex matched 12 healthy subjects as control group. All subjects were subjected to Careful history and copmlete examination with stress upon symptoms and signs of chronic liver diseases. Investigations include liver function tests; viral markers (Anti HCV antibodies & PCR for HCV). Serum fasting glucose; serum fasting insulin; homeostasis model assessment (HOMA), liver biopsy and abdominal ultrasound. Results: No correlation between viral load and hepatic fibrosis in HCV infected patients. Liver fibrosis is considerably higher among HCV patients with elevated serum transaminase levels. Insulin resistance is present in HCV infected cases compared with control group and it is positively correlated with liver fibrosis. Conclusion: The present data support the hypothesis that insulin resistance may increase the rate of fibrosis progression in non diabetic patients with chronic HCV. Follow up of hyperinsulinemia by serial measurement of HOMA test in non diabetic HCV infected patients may be a biochemical indicator for progression of liver fibrosis. PMID:21475535
Zhou, Zhiwei; Yang, Yanling; Li, Xing
2015-11-01
Large amounts of drinking water treatment sludge (DWTS) are produced during the flocculation or flotation process. The recycling of DWTS is important for reducing and reclaiming the waste residues from drinking water treatment. To improve the coagulation step of the DWTS recycling process, power ultrasound was used as a pretreatment to disintegrate the DWTS and degrade or inactivate the constituents that are difficult to remove by coagulation. The effects of ultrasound pretreatment on the characteristics of DWTS, including the extent of disintegration, variation in DWTS floc characteristics, and DWTS dewaterability, were investigated. The capacity of the recycling process to remove particulates and organic matter from low-turbidity surface water compared to a control treatment process without DWTS was subsequently evaluated. The coagulation mechanism was further investigated by analyzing the formation, breakage, and re-growth of re-coagulated flocs. Our results indicated that under the low energy density applied (0.03-0.033 W/mL) for less than 15 min at a frequency of 160 kHz, the level of organic solubilization was less elevated, which was evidenced by the lower release of proteins and polysaccharides and lower fluorescence intensities of humic- and protein-like substances. The applied ultrasound conditions had an adverse effect on the dewaterability of the DWTS. Ultrasound pretreatment had no significant impact on the pH or surface charge of the DWTS flocs, whereas particle size decreased slightly and the specific surface area was moderately increased. The pollution removal capacity decreased somewhat for the recycled sonicated DWTS treatment, which was primarily ascribed to organic solubilization rather than variability in the floc characteristics of sonicated DWTS. The main coagulation mechanism was floc sweeping and physical adsorption. The breakage process of the flocs formed by the recycling process displayed distinct irreversibility, and the flocs were stronger and more resistant to breakage compared to those from the control treatment. Copyright © 2015 Elsevier B.V. All rights reserved.
Güdücü, Nilgün; Sidar, Güliz; İşçi, Herman; Yiğiter, Alin Başgül; Dünder, İlkkan
2013-10-01
To present the indications and diagnosis in adolescents undergoing transrectal ultrasound (RU). Retrospective chart review. Adolescents presenting to gynecology clinic between January 1, 2005 and December 31, 2012. Detection of RU, transvaginal, and transabdominal (AU) ultrasound indications, and final diagnosis. The main indications for RU were menstrual abnormalities, pelvic pain-dysmenorrhea, and vulvovaginitis. When compared according to final diagnosis adolescents with vulvovaginitis (13.9%) and amenorrhea (8.3%) were evaluated more with RU. RU is highly acceptable and it provides images superior to AU. It can be used in adolescents to visualize the pelvic organs and to exclude genital abnormalities and mass lesions. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Seto, Jennifer E; Polat, Baris E; Lopez, Renata F V; Blankschtein, Daniel; Langer, Robert
2010-07-01
The simultaneous application of ultrasound and the surfactant sodium lauryl sulfate (referred to as US/SLS) to skin enhances transdermal drug delivery (TDD) in a synergistic mechanical and chemical manner. Since full-thickness skin (FTS) and split-thickness skin (STS) differ in mechanical strength, US/SLS treatment may have different effects on their transdermal transport pathways. Therefore, we evaluated STS as an alternative to the well-established US/SLS-treated FTS model for TDD studies of hydrophilic permeants. We utilized the aqueous porous pathway model to compare the effects of US/SLS treatment on the skin permeability and the pore radius of pig and human FTS and STS over a range of skin electrical resistivity values. Our findings indicate that the US/SLS-treated pig skin models exhibit similar permeabilities and pore radii, but the human skin models do not. Furthermore, the US/SLS-enhanced delivery of gold nanoparticles and quantum dots (two model hydrophilic macromolecules) is greater through pig STS than through pig FTS, due to the presence of less dermis that acts as an artificial barrier to macromolecules. In spite of greater variability in correlations between STS permeability and resistivity, our findings strongly suggest the use of 700microm-thick pig STS to investigate the in vitro US/SLS-enhanced delivery of hydrophilic macromolecules. 2010 Elsevier B.V. All rights reserved.
Role of ultrasound in colorectal diseases.
Bor, Renáta; Fábián, Anna; Szepes, Zoltán
2016-11-21
Ultrasound is an undervalued non-invasive examination in the diagnosis of colonic diseases. It has been replaced by the considerably more expensive magnetic resonance imaging and computed tomography, despite the fact that, as first examination, it can usefully supplement the diagnostic process. Transabdominal ultrasound can provide quick information about bowel status and help in the choice of adequate further examinations and treatment. Ultrasonography, as a screening imaging modality in asymptomatic patients can identify several colonic diseases such as diverticulosis, inflammatory bowel disease or cancer. In addition, it is widely available, cheap, non-invasive technique without the use of ionizing radiation, therefore it is safe to use in childhood or during pregnancy, and can be repeated at any time. New ultrasound techniques such as elastography, contrast enhanced and Doppler ultrasound, mini-probes rectal and transperineal ultrasonography have broadened the indication. It gives an overview of the methodology of various ultrasound examinations, presents the morphology of normal bowel wall and the typical changes in different colonic diseases. We will pay particular attention to rectal and transperineal ultrasound because of their outstanding significance in the diagnosis of rectal and perineal disorders. This article seeks to overview the diagnostic impact and correct indications of bowel ultrasound.
Bachanek, Michał; Trojanowski, Seweryn; Cendrowski, Krzysztof; Sawicki, Włodzimierz
2013-01-01
Aim To assess the diagnostic value of the risk of malignancy indices and simple ultrasound- based rules in preoperative differentiation of adnexal masses. Material and methods Retrospective examination of 87 patients admitted to hospital due to adnexal tumors. The lesions were evaluated on the basis of international ultrasound classification of ovarian tumors and four risk of malignancy indices were calculated based on ultrasound examination, concentration of CA 125 and menopausal status. Results The patients were aged between 17 and 79, the mean age was 44.5 (standard deviation SD=16.6). Most of the patients (60.91%) were before their menopause. The sensitivity of the simple ultrasound-based rules in the diagnosis of malignancies equaled 64.71% and the specificity constituted 90.00%. A significant statistical difference in the presence of the malignant process was demonstrated in relation to age, menopausal status, CA 125 concentration and analyzed ultrasound score. All indices were characterized by similar sensitivity and specificity. The highest specificity and predictive value of malignant lesions out of the assessed ones was demonstrated by the risk of malignancy index proposed by Yamamoto. The risk of malignancy index according to Jacobs, however, showed the highest predictive value in the case of non-malignant lesions. Conclusions The multiparametric ultrasound examination may facilitate the selection of patients with adnexal tumors to provide them with an appropriate treatment – observation, laparotomy and laparoscopy. These parameters constitute a simple ambulatory method of determining the character of adnexal masses before recommending appropriate treatment. PMID:26674849
Determining localized anode condition to maintain effective corrosion protection.
DOT National Transportation Integrated Search
2010-01-01
Thermal sprayed zinc anodes used for impressed current cathodic protection of reinforced concrete deteriorate over time. : Two different technologies, ultrasound and electrical circuit resistance combined with water permeability, were : investigated ...
NASA Technical Reports Server (NTRS)
Arbeille, P.; Berson, M.; Blondeau, B.; Durand, A.; Bodard, S.; Locatelli, A.; Fox, G. E. (Principal Investigator)
1995-01-01
The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).
Stiermaier, Thomas; Okon, Thomas; Fengler, Karl; Mueller, Ulrike; Hoellriegel, Robert; Schuler, Gerhard; Desch, Steffen; Lurz, Philipp
2016-06-12
Recent studies have reported a considerable number of non-responders after renal sympathetic de-nervation (RSD) with radiofrequency technology. Here we report our results of repeat RSD using ultrasound in these patients. A cohort study was performed in patients who underwent ultrasound RSD after non-response to RSD with radiofrequency. Non-response was defined as mean daytime systolic blood pressure ≥140 mmHg and/or a reduction of ≤10 mmHg in ambulatory blood pressure measurement (ABPM) ≥6 months after radiofrequency denervation. ABPM was recorded at baseline, post radiofrequency RSD as well as at three and six months post ultrasound RSD. A total of 24 non-responders underwent retreatment with the ultrasound device at a mean 15.3±8.2 months after radiofrequency RSD. Ultrasound RSD was performed successfully in all patients without severe adverse events. Mean daytime systolic blood pressure changed from 161.7±14.6 mmHg at baseline to 158.5±9.5 mmHg post radiofrequency RSD and to 150.5±10.4 mmHg and 151.6±11.0 mmHg at three and six months, respectively, post ultrasound RSD (p<0.01 with repeated measures analysis of variance). The main results of post hoc testing were as follows: baseline versus post radiofrequency RSD, p=0.83; baseline versus three months post ultrasound RSD, p=0.01; and baseline versus six months post ultrasound RSD, p=0.04. Ultrasound RSD appears to be safe and an effective therapeutic approach in patients not responding to previous RSD with radiofrequency technology.
Wang, Quanzhen; Chen, Guo; Yersaiyiti, Hayixia; Liu, Yuan; Cui, Jian; Wu, Chunhui; Zhang, Yunwei; He, Xueqing
2012-01-01
Switchgrass is a perennial C4 plant with great potential as a bioenergy source and, thus, a high demand for establishment from seed. This research investigated the effects of ultrasound treatment on germination and seedling growth in switchgrass. Using an orthogonal matrix design, conditions for the ultrasound pretreatment in switchgrass seed, including sonication time (factor A), sonication temperature (factor B) and ultrasound output power (factor C), were optimized for germinating and stimulating seedling growth (indicated as plumular and radicular lengths) through modeling analysis. The results indicate that sonication temperature (B) was the most effective factor for germination, whereas output power (C) had the largest effect on seedling growth when ultrasound treatment was used. Combined with the analyses of range, variance and models, the final optimal ultrasonic treatment conditions were sonication for 22.5 min at 39.7°C and at an output power of 348 W, which provided the greatest germination percentage and best seedling growth. For this study, the orthogonal matrix design was an efficient method for optimizing the conditions of ultrasound seed treatment on switchgrass. The electrical conductivity of seed leachates in three experimental groups (control, soaked in water only, and ultrasound treatment) was determined to investigate the effects of ultrasound on seeds and eliminate the effect of water in the ultrasound treatments. The results showed that the electrical conductivity of seed leachates during either ultrasound treatment or water bath treatment was significantly higher than that of the control, and that the ultrasound treatment had positive effects on switchgrass seeds.
Low-frequency quantitative ultrasound imaging of cell death in vivo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadeghi-Naini, Ali; Falou, Omar; Czarnota, Gregory J.
Purpose: Currently, no clinical imaging modality is used routinely to assess tumor response to cancer therapies within hours to days of the delivery of treatment. Here, the authors demonstrate the efficacy of ultrasound at a clinically relevant frequency to quantitatively detect changes in tumors in response to cancer therapies using preclinical mouse models.Methods: Conventional low-frequency and corresponding high-frequency ultrasound (ranging from 4 to 28 MHz) were used along with quantitative spectroscopic and signal envelope statistical analyses on data obtained from xenograft tumors treated with chemotherapy, x-ray radiation, as well as a novel vascular targeting microbubble therapy.Results: Ultrasound-based spectroscopic biomarkers indicatedmore » significant changes in cell-death associated parameters in responsive tumors. Specifically changes in the midband fit, spectral slope, and 0-MHz intercept biomarkers were investigated for different types of treatment and demonstrated cell-death related changes. The midband fit and 0-MHz intercept biomarker derived from low-frequency data demonstrated increases ranging approximately from 0 to 6 dBr and 0 to 8 dBr, respectively, depending on treatments administrated. These data paralleled results observed for high-frequency ultrasound data. Statistical analysis of ultrasound signal envelope was performed as an alternative method to obtain histogram-based biomarkers and provided confirmatory results. Histological analysis of tumor specimens indicated up to 61% cell death present in the tumors depending on treatments administered, consistent with quantitative ultrasound findings indicating cell death. Ultrasound-based spectroscopic biomarkers demonstrated a good correlation with histological morphological findings indicative of cell death (r{sup 2}= 0.71, 0.82; p < 0.001).Conclusions: In summary, the results provide preclinical evidence, for the first time, that quantitative ultrasound used at a clinically relevant frequency, in addition to high-frequency ultrasound, can detect tissue changes associated with cell death in vivo in response to cancer treatments.« less
Fusion of fuzzy statistical distributions for classification of thyroid ultrasound patterns.
Iakovidis, Dimitris K; Keramidas, Eystratios G; Maroulis, Dimitris
2010-09-01
This paper proposes a novel approach for thyroid ultrasound pattern representation. Considering that texture and echogenicity are correlated with thyroid malignancy, the proposed approach encodes these sonographic features via a noise-resistant representation. This representation is suitable for the discrimination of nodules of high malignancy risk from normal thyroid parenchyma. The material used in this study includes a total of 250 thyroid ultrasound patterns obtained from 75 patients in Greece. The patterns are represented by fused vectors of fuzzy features. Ultrasound texture is represented by fuzzy local binary patterns, whereas echogenicity is represented by fuzzy intensity histograms. The encoded thyroid ultrasound patterns are discriminated by support vector classifiers. The proposed approach was comprehensively evaluated using receiver operating characteristics (ROCs). The results show that the proposed fusion scheme outperforms previous thyroid ultrasound pattern representation methods proposed in the literature. The best classification accuracy was obtained with a polynomial kernel support vector machine, and reached 97.5% as estimated by the area under the ROC curve. The fusion of fuzzy local binary patterns and fuzzy grey-level histogram features is more effective than the state of the art approaches for the representation of thyroid ultrasound patterns and can be effectively utilized for the detection of nodules of high malignancy risk in the context of an intelligent medical system. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Kliper, Yael; Ben-Ami, Moshe; Perlitz, Yuri
2014-01-01
The aim of this study was to assess the effect of mild pressure applied on the abdominal wall by the ultrasound transducer on fetal cephalic indices. We examined by ultrasound 60 fetuses of healthy women, at 20-24 weeks of pregnancy, during routine prenatal evaluation. For every fetus biparietal diameter and head circumference were measured, with and without applying mild pressure by the ultrasound transducer. The weight and gestational age (GA) were calculated. The pressure applied by the transducer had a significant effect on the cephalic indices and on the weight and GA evaluations (p < 0.001). Fetal positioning significantly affected the impact that applied pressure had on head circumference and on the weight evaluation derived from it (p < 0.05). Applied pressure by an abdominal ultrasound probe affects cephalic indices and the derived weight and GA estimations. This may lead to incorrect diagnoses or hide pathological findings. The effect of applied pressure depends on fetal positioning. The examiner must be aware of this effect when evaluating the results of the measurements.
Use of Ultrasound Elastography in the Assessment of the Musculoskeletal System.
Paluch, Łukasz; Nawrocka-Laskus, Ewa; Wieczorek, Janusz; Mruk, Bartosz; Frel, Małgorzata; Walecki, Jerzy
2016-01-01
This article presents possible applications of ultrasound elastography in musculoskeletal imaging based on the available literature, as well as the possibility of extending indications for the use of elastography in the future. Ultrasound elastography (EUS) is a new method that shows structural changes in tissues following application of physical stress. Elastography techniques have been widely used to assess muscles and tendons in vitro since the early parts of the twentieth century. Only recently with the advent of new technology and creation of highly specialized ultrasound devices, has elastography gained widespread use in numerous applications. The authors performed a search of the Medline/PubMed databases for original research and reviewed publications on the application of ultrasound elastography for musculoskeletal imaging. All publications demonstrate possible uses of ultrasound elastography in examinations of the musculoskeletal system. The most widely studied areas include the muscles, tendons and rheumatic diseases. There are also reports on the employment in vessel imaging. The main limitation of elastography as a technique is above all the variability of applied pressure during imaging, which is operator-dependent. It would therefore be reasonable to provide clear guidelines on the technique applied, as well as clear indications for performing the test. It is important to develop methods for creating artifact-free, closed-loop, compression-decompression cycles. The main advantages include cost-effectiveness, short duration of the study, non-invasive nature of the procedure, as well as a potentially broader clinical availability. There are no clear guidelines with regard to indications as well as examination techniques. Ultrasound elastography is a new and still poorly researched method. We conclude, however, that it can be widely used in the examinations of musculoskeletal system. Therefore, it is necessary to conduct large, multi-center studies to determine the methodology, indications and technique of examination.
Grewal, Jagteshwar; Zhang, Jun; Mikolajczyk, Rafael T; Ford, Jessie
2010-08-01
Estimates of gestational age based on early second-trimester ultrasound often differ from that based on the last menstrual period (LMP) even when a woman is certain about her LMP. Discrepancies in these gestational age estimates may be associated with an increased risk of cesarean section and low birth weight. We analyzed 7228 singleton, low-risk, white women from The Routine Antenatal Diagnostic Imaging with Ultrasound trial. The women were recruited at less than 14 weeks of gestation and received ultrasound exams between 15 and 22 weeks. Our results indicate that among nulliparous women, the risk of cesarean section increased from 10% when the ultrasound-based gestational age exceeded the LMP-based estimate by 4 days to 60% when the discrepancy increased to 21 days. Moreover, for each additional day the ultrasound-based estimate exceeded the LMP-based estimate, birth weight was higher by 9.6 g. Our findings indicate that a positive discrepancy (i.e., ultrasound-based estimate exceeds LMP-based estimate) in gestational age is associated with an increased risk of cesarean section. A negative discrepancy, by contrast, may reflect early intrauterine growth restriction and an increased risk of low birth weight. Copyright Thieme Medical Publishers.
Carotid disease at age 73 and cognitive change from age 70 to 76 years: A longitudinal cohort study
Allerhand, Michael; Eadie, Elizabeth; Thomas, Avril; Corley, Janey; Pattie, Alison; Taylor, Adele; Shenkin, Susan D; Cox, Simon; Gow, Alan; Starr, John M; Deary, Ian J
2016-01-01
Cognitive decline and carotid artery atheroma are common at older ages. In community-dwelling subjects, we assessed cognition at ages 70, 73 and 76 and carotid Doppler ultrasound at age 73, to determine whether carotid stenosis was related to cognitive decline. We used latent growth curve models to examine associations between four carotid measures (internal carotid artery stenosis, velocity, pulsatility and resistivity indices) and four cognitive ability domains (memory, visuospatial function, crystallised intelligence, processing speed) adjusted for cognitive ability at age 11, current age, gender and vascular risk factors. Amongst 866 participants, carotid stenosis (median 12.96%) was not associated with cognitive abilities at age 70 or cognitive decline from age 70 to 76. Increased ICA pulsatility and resistivity indices were associated with slower processing speed (both P < 0.001) and worse visuospatial function (P = 0.036, 0.031, respectively) at age 70, and declining crystallised intelligence from ages 70 to 76 (P = 0.008, 0.006, respectively). The findings suggest that vascular stiffening, rather than carotid luminal narrowing, adversely influences cognitive ageing and provides a potential target for ameliorating age-related cognitive decline. PMID:28155579
Carotid disease at age 73 and cognitive change from age 70 to 76 years: A longitudinal cohort study.
Wardlaw, Joanna M; Allerhand, Michael; Eadie, Elizabeth; Thomas, Avril; Corley, Janey; Pattie, Alison; Taylor, Adele; Shenkin, Susan D; Cox, Simon; Gow, Alan; Starr, John M; Deary, Ian J
2017-08-01
Cognitive decline and carotid artery atheroma are common at older ages. In community-dwelling subjects, we assessed cognition at ages 70, 73 and 76 and carotid Doppler ultrasound at age 73, to determine whether carotid stenosis was related to cognitive decline. We used latent growth curve models to examine associations between four carotid measures (internal carotid artery stenosis, velocity, pulsatility and resistivity indices) and four cognitive ability domains (memory, visuospatial function, crystallised intelligence, processing speed) adjusted for cognitive ability at age 11, current age, gender and vascular risk factors. Amongst 866 participants, carotid stenosis (median 12.96%) was not associated with cognitive abilities at age 70 or cognitive decline from age 70 to 76. Increased ICA pulsatility and resistivity indices were associated with slower processing speed (both P < 0.001) and worse visuospatial function ( P = 0.036, 0.031, respectively) at age 70, and declining crystallised intelligence from ages 70 to 76 ( P = 0.008, 0.006, respectively). The findings suggest that vascular stiffening, rather than carotid luminal narrowing, adversely influences cognitive ageing and provides a potential target for ameliorating age-related cognitive decline.
Recent advances in ultrasound-triggered therapy.
Yang, Chaopin; Li, Yue; Du, Meng; Chen, Zhiyi
2018-04-27
As a non-invasive and real-time diagnostic technique, ultrasound has provided a novel strategy for targeted treatment. With the rapid development of ultrasonic technique and ultrasound contrast agents (UCAs), spatiotemporally controllable application of ultrasound with or without UCAs makes it possible for site-specific delivery of therapeutic agents and targeted modulation with minimal side effects, which indicated a promising therapy in clinical use. This review will describe the main mechanism of targeted therapy induced by ultrasound briefly, then focus on the current application of ultrasound mediated targeted therapy in various fields including tumour, cardiovascular disease, central nervous system, skeletal muscle system diseases and stem cells therapy. In addition, ongoing challenges of ultrasound-mediated targeted therapy for further research and its clinical use are reviewed.
Ghasemi, Negareh; Zare, Firuz; Davari, Pooya; Vilathgamuwa, Mahinda; Ghosh, Arindam; Langton, Christian; Weber, Peter
2017-02-01
Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectric transducer impedance has been discussed in different literatures, the trend of the nonlinearity at different frequencies with respect to excitation voltage variations has not been clearly investigated in practice. In this paper, to demonstrate how the nonlinearity behaves, a sandwich piezoceramic transducer was excited at different frequencies. Different excitation signals were generated using a linear power amplifier and a multilevel converter within a range of 30-200V. Empirical relation was developed to express the resistance of the piezoelectric transducer as a nonlinear function of both excitation voltage and resonance frequency. The impedance measurements revealed that at higher voltage ranges, the piezoelectric transducer can be easily saturated. Also, it was shown that for the developed ultrasound system composed of two transducers (one transmitter and one receiver), the output voltage measured across receiver is a function of a voltage across the resistor in the RLC branches and is related to the resonance frequencies of the ultrasound transducer. Copyright © 2016 Elsevier B.V. All rights reserved.
Power ultrasound-assisted cleaner leather dyeing technique: influence of process parameters.
Sivakumar, Venkatasubramanian; Rao, Paruchuri Gangadhar
2004-03-01
The application of power ultrasound to leather processing has a significant role in the concept of "clean technology" for leather production. The effect of power ultrasound in leather dyeing has been compared with dyeing in the absence of ultrasound and conventional drumming. The power ultrasound source used in these experiments was ultrasonic cleaner (150 W and 33 kHz). The effect of various process parameters such as amount of dye offer, temperature, and type of dye has been experimentally found out. The effect of presonication of dye solution as well as leather has been studied. Experiments at ultrasonic bath temperature were carried out to find out the combined thermal as well as stirring effects of ultrasound. Dyeing in the presence of ultrasound affords about 37.5 (1.8 times) difference as increase in % dye exhaustion or about 50% decrease in the time required for dyeing compared to dyeing in the absence of ultrasound for 4% acid red dye. About 29 (1.55 times) increase in % dye exhaustion or 30% reduction in time required for dyeing was observed using ultrasound at stationary condition compared with conventional dynamic drumming conditions. The effect of ultrasound at constant temperature conditions with a control experiment has also been studied. The dye exhaustion increases as the temperature increases (30-60 degrees C) and better results are observed at higher temperature due to the use of ultrasound. Presonication of dye solution or crust leather prior to the dyeing process has no significant improvement in dye exhaustion, suggesting ultrasound effect is realized when it is applied during the dyeing process. The results indicate that 1697 and 1416 ppm of dye can be reduced in the spent liquor due to the use of ultrasound for acid red (for 100 min) and acid black (for 3 h) dyes, respectively, thereby reducing the pollution load in the effluent stream. The color yield of the leather as inferred from the reflectance measurement indicates that dye offer can be halved when ultrasound is employed to promote dyeing. Scanning electron microscopy analysis of the cross section of the dyed leather indicates that fiber structure is not affected due to the use of ultrasound under the given process conditions. The present study clearly demonstrates that ultrasound can be used as a tool to improve the rate of exhaustion of dye, reduce pollution load in the spent effluent liquor, and improve the quality of leather produced. The study also offered provision to employ optimum levels of chemicals and increases percentage exhaustion for a given time, thereby limiting the pollution load in the tannery effluent, which is of great social concern.
Ultrasound Velocity Measurements in High-Chromium Steel Under Plastic Deformation
NASA Astrophysics Data System (ADS)
Lunev, Aleksey; Bochkareva, Anna; Barannikova, Svetlana; Zuev, Lev
2016-04-01
In the present study, the variation of the propagation velocity of ultrasound in the plastic deformation of corrosion-resistant high-chromium steel 40X13 with ferrite-carbide (delivery status), martensitic (quenched) and sorbitol (after high-temperature tempering) structures have beem studied/ It is found that each state shows its view of the loading curve. In the delivery state diagram loading is substantially parabolic throughout, while in the martensitic state contains only linear strain hardening step and in the sorbitol state the plastic flow curve is three-step. The velocity of ultrasonic surface waves (Rayleigh waves) was measured simultaneously with the registration of the loading curve in the investigated steel in tension. It is shown that the dependence of the velocity of ultrasound in active loading is determined by the law of plastic flow, that is, the staging of the corresponding diagram of loading. Structural state of the investigated steel is not only changing the type of the deformation curve under uniaxial tension, but also changes the nature of ultrasound speed of deformation.
Xing, Jida; Chen, Jie
2015-06-23
In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous design, the new design reduced sensing time from 20 s to 12 s, and the sensor's average error from 3.97 mW/cm2 to 1.31 mW/cm2 respectively.
Xing, Jida; Chen, Jie
2015-01-01
In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous design, the new design reduced sensing time from 20 s to 12 s, and the sensor’s average error from 3.97 mW/cm2 to 1.31 mW/cm2 respectively. PMID:26110412
Bhaskar, Vaishnavi; Chan, Hsun-Liang; MacEachern, Mark; Kripfgans, Oliver D
2018-05-23
Ultrasonography has shown promising diagnostic value in dental implant imaging research; however, exactly how ultrasound was used and at what stage of implant therapy it can be applied has not been systematically evaluated. Therefore, the aim of this review is to investigate potential indications of ultrasound use in the three implant treatment phases, namely planning, intraoperative and postoperative phase. Eligible manuscripts were searched in major databases with a combination of key words related to the use of ultrasound imaging in implant therapy. An initial search yielded 414 articles, after further review, 28 articles were finally included for this systematic review. Ultrasound was found valuable, though at various development stages, for evaluating (1) soft tissues, (2) hard tissues (3) vital structures and (4) implant stability. B-mode, the main function to image anatomical structures of interest, has been evaluated in pre-clinical and clinical studies. Quantitative ultrasound parameters, e.g. sound speed and amplitude, are being developed to evaluate implant-bone stability, mainly in simulation and pre-clinical studies. Ultrasound could be potentially useful in all 3 treatment phases. In the planning phase, ultrasound could evaluate vital structures, tissue biotype, ridge width/density, and cortical bone thickness. During surgery, it can provide feedback by identifying vital structures and bone boundary. At follow-up visits, it could evaluate marginal bone level and implant stability. Understanding the current status of ultrasound imaging research for implant therapy would be extremely beneficial for accelerating translational research and its use in dental clinics.
Conlon, Thomas W; Himebauch, Adam S; Fitzgerald, Julie C; Chen, Aaron E; Dean, Anthony J; Panebianco, Nova; Darge, Kassa; Cohen, Meryl S; Greeley, William J; Berg, Robert A; Nishisaki, Akira
2015-03-01
To determine the feasibility and describe the process of implementing a pediatric critical care bedside ultrasound program in a large academic PICU and to evaluate the impact of bedside ultrasound on clinical management. Retrospective case series, description of program implementation. Single-center quaternary noncardiac PICU in a children's hospital. Consecutive patients from January 22, 2012, to July 22, 2012, with bedside ultrasounds performed and interpreted by pediatric critical care practitioners. A pediatric critical care bedside ultrasound program consisting of a 2-day immersive course followed by clinical performance with internal quality assurance review was implemented. Studies performed in the PICU following training were documented and reviewed against reference standards including subspecialist-performed ultrasound or clinical response. Seventeen critical care faculties and eight fellows recorded 201 bedside ultrasound studies over 6 months in defined core applications: 57 procedural (28%), 76 hemodynamic (38%), 35 thoracic (17%), and 33 abdominal (16%). A quality assurance review identified 23 studies (16% of all nonprocedural studies) as critical (affected clinical management or gave valuable information). Forty-eight percent of those studies (11/23) were within the hemodynamic core. The proportion of critical studies were not significantly different across the applications (hemodynamic, 11/76 [15%] vs thoracic and abdominal, 12/68 [18%]; p = 0.65). Examples of critical studies include evidence of tamponade secondary to pleural effusions, identification of pulmonary hypertension, hemodynamic assessment before tracheal intubation, recognition of hypovolemia and systemic vascular resistance abnormalities, determination of pneumothorax, location of chest tube and urinary catheter, and differentiation of pleural fluid from pulmonary consolidation. Implementation of a critical care bedside ultrasound program for critical care providers in a large academic PICU is feasible. Bedside ultrasound evaluation and interpretation by intensivists affected the management of critically ill children.
Rescuing valuable genomes by animal cloning: a case for natural disease resistance in cattle.
Westhusin, M E; Shin, T; Templeton, J W; Burghardt, R C; Adams, L G
2007-01-01
Tissue banking and animal cloning represent a powerful tool for conserving and regenerating valuable animal genomes. Here we report an example involving cattle and the rescue of a genome affording natural disease resistance. During the course of a 2-decade study involving the phenotypic and genotypic analysis for the functional and genetic basis of natural disease resistance against bovine brucellosis, a foundation sire was identified and confirmed to be genetically resistant to Brucella abortus. This unique animal was utilized extensively in numerous animal breeding studies to further characterize the genetic basis for natural disease resistance. The bull died in 1996 of natural causes, and no semen was available for AI, resulting in the loss of this valuable genome. Fibroblast cell lines had been established in 1985, cryopreserved, and stored in liquid nitrogen for future genetic analysis. Therefore, we decided to utilize these cells for somatic cell nuclear transfer to attempt the production of a cloned bull and salvage this valuable genotype. Embryos were produced by somatic cell nuclear transfer and transferred to 20 recipient cows, 10 of which became pregnant as determined by ultrasound at d 40 of gestation. One calf survived to term. At present, the cloned bull is 4.5 yr old and appears completely normal as determined by physical examination and blood chemistry. Furthermore, in vitro assays performed to date indicate this bull is naturally resistant to B. abortus, Mycobacterium bovis, and Salmonella typhimurium, as was the original genetic donor.
Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.
Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A
2016-06-01
The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.
Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy
NASA Astrophysics Data System (ADS)
Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk
2017-03-01
A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.
Wear, Keith A; Nagaraja, Srinidhi; Dreher, Maureen L; Sadoughi, Saghi; Zhu, Shan; Keaveny, Tony M
2017-10-01
Clinical bone sonometers applied at the calcaneus measure broadband ultrasound attenuation and speed of sound. However, the relation of ultrasound measurements to bone strength is not well-characterized. Addressing this issue, we assessed the extent to which ultrasonic measurements convey in vitro mechanical properties in 25 human calcaneal cancellous bone specimens (approximately 2×4×2cm). Normalized broadband ultrasound attenuation, speed of sound, and broadband ultrasound backscatter were measured with 500kHz transducers. To assess mechanical properties, non-linear finite element analysis, based on micro-computed tomography images (34-micron cubic voxel), was used to estimate apparent elastic modulus, overall specimen stiffness, and apparent yield stress, with models typically having approximately 25-30 million elements. We found that ultrasound parameters were correlated with mechanical properties with R=0.70-0.82 (p<0.001). Multiple regression analysis indicated that ultrasound measurements provide additional information regarding mechanical properties beyond that provided by bone quantity alone (p≤0.05). Adding ultrasound variables to linear regression models based on bone quantity improved adjusted squared correlation coefficients from 0.65 to 0.77 (stiffness), 0.76 to 0.81 (apparent modulus), and 0.67 to 0.73 (yield stress). These results indicate that ultrasound can provide complementary (to bone quantity) information regarding mechanical behavior of cancellous bone. Published by Elsevier Inc.
Sugaya, Tomoaki; Abe, Yota; Sakamoto, Masaaki
2014-09-01
[Purpose] The aim of this study was to investigate muscle thickness changes in the external oblique (EO), internal oblique (IO), and transversus abdominis (TrA) muscles between the neutral position and trunk rotation, under a state of rest without voluntary contractions, and isometric contractions to both sides with resistance of 50% of the maximum trunk rotation strength. [Subjects] The subjects of this study were 21 healthy young men. [Methods] Muscle thickness changes in the EO, IO, and TrA in each position and state were evaluated by ultrasound. The range of motion at maximum trunk rotation and the maximum strength of trunk rotation were measured using a hand-held dynamometer. [Results] In the neutral position and at 50% trunk rotation to the right side, the thicknesses of the IO and TrA significantly increased with resistance. In both states, the thicknesses of the IO and TrA significantly increased at 50% trunk rotation to the right side. [Conclusion] The muscular contractions of the IO and TrA were stronger during ipsilateral rotation than in the neutral position and with resistance than at rest. Moreover, the muscular contraction was strongest in the resistive state during ipsilateral rotation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Byers, Loren W.; Ten Cate, James A.; Johnson, Paul A.
2012-06-28
Nonlinear resonance ultrasound spectroscopy experiments conducted on concrete cores, one chemically and mechanically damaged by alkali-silica reactivity, and one undamaged, show that this material displays highly nonlinear wave behavior, similar to many other damaged materials. They find that the damaged sample responds more nonlinearly, manifested by a larger resonant peak and modulus shift as a function of strain amplitude. The nonlinear response indicates that there is a hysteretic influence in the stress-strain equation of state. Further, as in some other materials, slow dynamics are present. The nonlinear response they observe in concrete is an extremely sensitive indicator of damage. Ultimately,more » nonlinear wave methods applied to concrete may be used to guide mixing, curing, or other production techniques, in order to develop materials with particular desired qualities such as enhanced strength or chemical resistance, and to be used for damage inspection.« less
NASA Astrophysics Data System (ADS)
Ortuño, Carmen; Pérez-Munuera, Isabel; Puig, Ana; Riera, Enrique; Garcia-Perez, J. V.
2010-01-01
Power ultrasound application on convective drying of foodstuffs may be considered an emergent technology. This work deals with the influence of power ultrasound on drying of natural materials addressing the kinetic as well as the product's microstructure. Convective drying kinetics of orange peel slabs (thickness 5.95±0.41 mm) were carried out at 40 ∘C and 1 m/s with (US) and without (AIR) power ultrasound application. A diffusion model considering external resistance to mass transfer was considered to describe drying kinetics. Fresh, US and AIR dried samples were analyzed using Cryo-SEM. Results showed that drying kinetics of orange peel were significantly improved by the application of power ultrasound. From modeling, it was observed a significant (p¡0.05) increase in both mass transfer coefficient and effective moisture diffusivity. The effects on mass transfer properties were confirmed from microestructural observations. In the cuticle surface, the pores were obstructed by wax components scattering, which evidence the ultrasonic effects on the interfaces. The cells of the flavedo were compressed and large intercellular air spaces were generated in the albedo facilitating water transfer through it.
Nishimura, Takayuki; Arima, Kazuhiko; Abe, Yasuyo; Kanagae, Mitsuo; Mizukami, Satoshi; Okabe, Takuhiro; Tomita, Yoshihito; Goto, Hisashi; Horiguchi, Itsuko; Aoyagi, Kiyoshi
2018-01-01
Abstract The aim of the present study was to investigate the age-related patterns and the relationships between serum levels of tartrate-resistant acid phosphatase-5b (TRACP-5b) or bone-specific alkaline phosphatase (BAP), and the heel stiffness index measured by quantitative ultrasound (QUS) in 429 Japanese men, with special emphasis on 2 age groups (40–59 years and 60 years or over). The heel stiffness index (bone mass) was measured by QUS. Serum samples were collected, and TRACP-5b and BAP levels were measured. The stiffness index was significantly decreased with age. Log (TRACP-5b) was significantly increased with age, but Log (BAP) was stable. Generalized linear models showed that higher levels of Log (TRACP-5b) and Log (BAP) were correlated with a lower stiffness index after adjusting for covariates in men aged 60 years or over, but not in men aged 40 to 59 years. In conclusion, higher rates of bone turnover markers were associated with a lower stiffness index only in elderly men. These results may indicate a different mechanism of low bone mass among different age groups of men. PMID:29465590
Meola, Mario; Petrucci, Ilaria; Giovannini, Lisa; Samoni, Sara; Dellafiore, Carolina
2012-01-01
Gray-scale ultrasound is the diagnostic technique of choice in patients with suspected or known renal disease. Knowledge of the normal and abnormal sonographic morphology of the kidney and urinary tract is essential for a successful diagnosis. Conventional sonography must always be complemented by Doppler sampling of the principal arterial and venous vessels. B-mode scanning is performed with the patient in supine, prone or side position. The kidney can be imaged by the anterior, lateral or posterior approach using coronal, transverse and oblique scanning planes. Morphological parameters that must be evaluated are the coronal diameter, the parenchymal thickness and echogenicity, the structure and state of the urinary tract, and the presence of congenital anomalies that may mimic a pseudomass. The main renal artery and the hilar-intraparenchymal branches of the arterial and venous vessels should be accurately evaluated using color Doppler. Measurement of intraparenchymal resistance indices (IP, IR) provides an indirect and quantitative parameter of the stiffness and eutrophic or dystrophic remodeling of the intrarenal microvasculature. These parameters differ depending on age, diabetic and hypertensive disease, chronic renal glomerular disease, and interstitial, vascular and obstructive nephropathy.
Costley, David; Nesbitt, Heather; Ternan, Nigel; Dooley, James; Huang, Ying-Ying; Hamblin, Michael R; McHale, Anthony P; Callan, John F
2017-01-01
Combating antimicrobial resistance is one of the most serious public health challenges facing society today. The development of new antibiotics or alternative techniques that can help combat antimicrobial resistance is being prioritised by many governments and stakeholders across the globe. Antimicrobial photodynamic therapy is one such technique that has received considerable attention but is limited by the inability of light to penetrate through human tissue, reducing its effectiveness when used to treat deep-seated infections. The related technique sonodynamic therapy (SDT) has the potential to overcome this limitation given the ability of low-intensity ultrasound to penetrate human tissue. In this study, a Rose Bengal-antimicrobial peptide conjugate was prepared for use in antimicrobial SDT (ASDT). When Staphylococcus aureus and Pseudomonas aeruginosa planktonic cultures were treated with the conjugate and subsequently exposed to ultrasound, 5 log and 7 log reductions, respectively, in bacterial numbers were observed. The conjugate also displayed improved uptake by bacterial cells compared with a mammalian cell line (P ≤ 0.01), whilst pre-treatment of a P. aeruginosa biofilm with ultrasound resulted in a 2.6-fold improvement in sensitiser diffusion (P ≤ 0.01). A preliminary in vivo experiment involving ASDT treatment of P. aeruginosa-infected wounds in mice demonstrated that ultrasound irradiation of conjugate-treated wounds affects a substantial reduction in bacterial burden. Combined, the results obtained from this study highlight ASDT as a targeted broad-spectrum novel modality with potential for the treatment of deep-seated bacterial infections. Copyright © 2016. Published by Elsevier B.V.
Cohen, Gadi; Natsheh, Hiba; Sunny, Youhan; Bawiec, Christopher R; Touitou, Elka; Lerman, Melissa A; Lazarovici, Philip; Lewin, Peter A
2015-09-01
The purpose of this work was to investigate whether low-frequency, low-intensity (20 kHz, <100 mW/cm(2), spatial-peak, temporal-peak intensity) ultrasound, delivered with a lightweight (<100 g), tether-free, fully wearable, battery-powered applicator, is capable of reducing inflammation in a mouse model of rheumatoid arthritis. The therapeutic, acute, anti-inflammatory effect was estimated from the relative swelling induced in mice hindlimb paws. In an independent, indirect approach, the inflammation was bio-imaged by measuring glycolytic activity with near-infrared labeled 2-deoxyglucose. The outcome of the experiments indicated that the combination of ultrasound exposure and topical application of 0.1% (w/w) betamethasone gel resulted in statistically significantly (p < 0.05) enhanced anti-inflammatory activity in comparison with drug or ultrasound treatment alone. The present study underscores the potential benefits of low-frequency, low-intensity ultrasound-assisted drug delivery. However, the proof of concept presented indicates the need for additional experiments to systematically evaluate and optimize the potential of, and the conditions for, tolerable low-frequency, low-intensity ultrasound-promoted non-invasive drug delivery. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Jin, Jian; Ma, Haile; Wang, Kai; Yagoub, Abu El-Gasim A; Owusu, John; Qu, Wenjuan; He, Ronghai; Zhou, Cunshan; Ye, Xiaofei
2015-05-01
The aim of this study was to investigate the effect of multi-frequency power ultrasound (sweeping frequency and pulsed ultrasound (SFPU) and sequential dual frequency ultrasound (SDFU)) on the enzymolysis of corn gluten meal (CGM) and on the structures of the major protein fractions (zein, glutelin) of CGM. The results showed that multi-frequency power ultrasound pretreatments improved significantly (P<0.05) the degree of hydrolysis and conversion rate of CGM. The changes in UV-Vis spectra, fluorescence emission spectra, surface hydrophobicity (H0), and the content of SH and SS groups indicated unfolding of zein and glutelin by ultrasound. The circular dichroism analysis showed that both pretreatments decreased α-helix and increased β-sheet of glutelin. The SFPU pretreatment had little impact on the secondary structure of zein, while the SDFU increased the α-helix and decreased the β-sheet remarkably. Scanning electron microscope indicated that both pretreatments destroyed the microstructures of glutelin and CGM, reduced the particle size of zein despite that the SDFU induced aggregation was observed. In conclusion, multi-frequency power ultrasound pretreatment is an efficient method in protein proteolysis due to its sonochemistry effect on the molecular conformation as well as on the microstructure of protein. Copyright © 2014 Elsevier B.V. All rights reserved.
Xu, Min; Xin, Fang; Li, Xunfeng; Huai, Xiulan; Liu, Hui
2015-03-01
The apparent kinetic of the ultrasound assisted liquid-phase dehydrogenation of isopropanol over Raney nickel catalyst was determined in the temperature range of 346-353 K. Comparison of the effects of ultrasound and mechanical agitation on the isopropanol dehydrogenation was investigated. The ultrasound assisted dehydrogenation rate was significantly improved when relatively high power density was used. Moreover, the Isopropanol-Acetone-Hydrogen chemical heat pump (IAH-CHP) with ultrasound irradiation, in which the endothermic reaction is exposure to ultrasound, was proposed. A mathematical model was established to evaluate its energy performance in term of the coefficient of performance (COP) and the exergy efficiency, into which the apparent kinetic obtained in this work was incorporated. The operating performances between IAH-CHP with ultrasound and mechanical agitation were compared. The results indicated that the superiority of the IAH-CHP system with ultrasound was present even if more than 50% of the power of the ultrasound equipment was lost. Copyright © 2014 Elsevier B.V. All rights reserved.
Effect of ultrasound on electrochemical chloride extraction from mortar
NASA Astrophysics Data System (ADS)
Chen, Yiqun; Yao, Wu; Zuo, Junqing
2018-03-01
In this paper, the effect of auxiliary ultrasound on electrochemical chloride extraction (ECE) was studied. The chloride removal efficiency was investigated by examining the chloride content with ultrasound-assisted ECE and changing the introducing time of ultrasound. The experimental results showed that removal of chloride ions was noted to be more effective in ECE treatment assisted with ultrasound treatment (UT). In addition, the lower w/c ratio led to more distinct effect of ultrasonic cavitation on chloride removal. Electrochemical behaviors measured with different treatment revealed that UT treatment was effective on moderating the corrosion condition. Microstructural analyses revealed a significant alteration in composition and morphology of cementitious phases with UT treatment. Pull-out tests indicated that ultrasound had a certain negative impact on the bond strength. Although the effect of introducing ultrasound in the first 2 weeks or the last 2 weeks on the extraction efficiency was not obvious, intermittent ultrasound could not only ensure the chloride extraction efficiency, but also reduce the adverse effect of ultrasound on the bond strength.
Ferreri, Suzanne L; Talish, Roger; Trandafir, Titi; Qin, Yi-Xian
2011-05-01
This study tests the hypothesis that an ultrasound generated dynamic mechanical signal can attenuate bone loss in an estrogen deficient model of osteopenia. Eighty-four 16-week-old Sprague-Dawley rats were divided into six groups: baseline control, age-matched control, ovariectomy (OVX) control, OVX+5mW/cm(2) ultrasound (US), OVX+30mW/cm(2) US and OVX+100mW/cm(2) US. Low intensity pulsed ultrasound (LIPUS) was delivered transdermally at the L4/L5 vertebrae, using gel-coupled plane wave US transducers. The signal, characterized by 200μs pulses of 1.5MHz sine waves repeating at 1kHz with spatial-averaged temporal-averaged (SATA) intensities of 5, 30 or 100mW/cm(2), was applied 20 min/day, 5 days/week for 4 weeks. OVX treatment reduced bone volume fraction 40% and compromised microstructure at 4 weeks. LIPUS treatment, however, significantly increased BV/TV (+33%) compared to OVX controls for the 100mW/cm(2) treated group. SMI and Tb.N showed significant improvements compared with OVX for the 100mW/cm(2) treated group and Tb.Th was significantly improved in the 30 and 100mW/cm(2) treated groups. Improvements in bone's microstructural characteristics with 100mW/cm(2) US treatment translated into improved load bearing characteristics, including a significant 42% increase in apparent level elastic modulus compared to OVX controls. Significant improvement of trabecular mechanical strength was also observed in the treated animals, e.g., principal compressive stress (represent bone's ability to resist loads) was significantly higher compared to OVX controls. Histomorphometric analysis also showed that treatment with 100mW/cm(2) US resulted in a 76% improvement in MS/BS. In addition, measures of bone quantity and quality at the femoral metaphysis suggest that LIPUS is site specific. This study indicates that localized ultrasound treatment, delivered at specific intensities, has beneficial effects on intact bone and may represent a novel intervention for bone loss. Copyright © 2011 Elsevier Inc. All rights reserved.
Ferreri, Suzanne L.; Talish, Roger; Trandafir, Titi; Qin, Yi-Xian
2011-01-01
This study tests the hypothesis that an ultrasound generated dynamic mechanical signal can attenuate bone loss in an estrogen deficient model of osteopenia. Eighty-four, sixteen week old Sprague-Dawley rats were divided into six groups: baseline control, age-matched control, ovariectomy (OVX) OVX control, OVX + 5 mW/cm2 ultrasound (US), OVX + 30 mW/cm2 US and OVX + 100 mW/cm2 US. Low intensity pulsed ultrasound (LIPUS) was delivered transdermally at the L4/L5 vertebrae, using gelcoupled plane wave US transducers. The signal, characterized by 200μs pulses of 1.5 MHz sine waves repeating at 1 kHz with spatial-averaged temporal-averaged (SATA) intensities of 5, 30 or 100mW/cm2, was applied 20 min/day, 5 days/week for 4 weeks. OVX treatment reduced bone volume fraction 40% and compromised microstructure at 4 weeks. LIPUS treatment, however, significantly increased BV/TV 33% compared to OVX controls for the 100mW/cm2 treated group. SMI, and Tb.N showed significant improvements compared with OVX for the 100mW/cm2 treated group and Tb.Th was significantly improved in the 30 and 100mW/cm2 treated groups. Improvements in bone’s microstructural characteristics with 100mW/cm2 US treatment translated into improved load bearing characteristics, including a significant, 42% increase in apparent level Elastic Modulus compared to OVX controls. Significant improvement of trabecular mechanical strength is also observed in the treated animals, e.g., principal compressive stress (represent bone’s ability to resist loads) was significantly higher compared to OVX controls. Histomorphometric analysis also showed that treatment with 100mW/cm2 US resulted in a 76% improvement in MS/BS. In addition, measures of bone quantity and quality at the femoral metaphysis suggest that LIPUS is site specific. This study indicates that ultrasound, delivered at specific intensities, has beneficial effects on intact bone and may represent a novel intervention for bone loss. PMID:21241838
Koulakis, John P; Rouch, Joshua; Huynh, Nhan; Dubrovsky, Genia; Dunn, James C Y; Putterman, Seth
2018-01-01
We search for cavitation in tumescent subcutaneous tissue of a live pig under application of pulsed, 1-MHz ultrasound at 8 W cm -2 spatial peak and pulse-averaged intensity. We find no evidence of broadband acoustic emission indicative of inertial cavitation. These acoustic parameters are representative of those used in external-ultrasound-assisted lipoplasty and in physical therapy and our null result brings into question the role of cavitation in those applications. A comparison of broadband acoustic emission from a suspension of ultrasound contrast agent in bulk water with a suspension injected subcutaneously indicates that the interstitial matrix suppresses cavitation and provides an additional mechanism behind the apparent lack of in-vivo cavitation to supplement the absence of nuclei explanation offered in the literature. We also find a short-lived cavitation signal in normal, non-tumesced tissue that disappears after the first pulse, consistent with cavitation nuclei depletion in vivo. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Potential use of an ultrasound antifouling technology as a ballast water treatment system
NASA Astrophysics Data System (ADS)
Estévez-Calvar, Noelia; Gambardella, Chiara; Miraglia, Francesco; Pavanello, Giovanni; Greco, Giuliano; Faimali, Marco; Garaventa, Francesca
2018-03-01
The aim of this study was to investigate, at a laboratory scale, the potentialities of an ultrasound-based treatment initially designed to eliminate fouling, as a ballast water treatment system. Therefore, early life stages of three different zooplanktonic species (Amphibalanus amphitrite, Brachionus plicatilis and Artemia salina) were exposed to ultrasound waves (20-22 kHz). The experimental set up included static assays with variations of time exposure (30 s, 60 s and 30 s on/60 s off/30 s on), material of tanks (stainless steel, galvanized steel and plastic) and position of the ultrasound source. Results showed that the treatment efficacy increased from 30 to 60 s and no differences were registered between 60 s-continuous exposure and pulse exposure. The highest efficacy was observed in Experiment I (metal-to-metal contact assay) with a mortality value of 93-95% for B. plicatilis and A. salina. It consisted of organisms located inside stainless steel tubes that were located in direct contact with the ultrasound source and treated for 60 s. Further, we found that, generally, A. amphitrite and B. plicatilis were the most resistant species to the ultrasound treatment whereas A. salina was the most sensitive. We further discuss that US may unlikely be used for commercial vessels, but may be used to treat ballast water in smaller ballast tanks as on board of mega yachts.
Qiao, Yangzi; Cao, Hua; Zhang, Shusheng; Yin, Hui; Wan, Mingxi
2013-01-01
Ultrasound contrast agents (UCAs) are frequently added into the focused ultrasound field as cavitation nuclei to enhance the therapeutic efficiency. Since their presence will distort the pressure field and make the process unpredictable, comprehension of their behaviors especially the active zone spatial distribution is an important part of better monitoring and using of UCAs. As shell materials can strongly alter the acoustic behavior of UCAs, two different shells coated UCAs, lipid-shelled and polymer-shelled UCAs, in a 1.2 MHz focused ultrasound field were studied by the Sonochemiluminescence (SCL) method and compared. The SCL spatial distribution of lipid-shelled group differed from that of polymer-shelled group. The shell material and the character of focused ultrasound field work together to the SCL distribution, causing the lipid-shelled group to have a maximum SCL intensity in pre-focal region at lower input power than that of polymer-shelled group, and a brighter SCL intensity in post-focal region at high input power. The SCL inactive area of these two groups both increased with the input power. The general behavior of the UCAs can be studied by both the average SCL intensity and the backscatter signals. As polymer-shelled UCAs are more resistant to acoustic pressure, they had a higher destruction power and showed less reactivation than lipid-shelled ones. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Arakelyan, M. M.
2017-11-01
The effect of ultrasound on motion of the Frenkel-Kontorova dislocations in aluminum has been studied with inclusion of the Peierls relief. A dislocation moves at a variable rate when overcoming the Peierls barrier. The dislocation mean free path is changed under action of ultrasound at various frequencies comparable to the dislocation transition time to a neighboring valley. The stress-strain dependences have been obtained for high and low strain rates. In both the cases, a disordering takes place; however, the disordering rates and characters are different. At the resonance frequency, the strain resistance decreases, the hardening stage is shortened and the disordering stage is elongated. The dependence of the coefficient of hardening on coordinate has three segments different in characters. The coefficient of hardening decreases at the resonance frequency.
Ultrasound-guided interventional procedures around the shoulder.
Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria
2016-01-01
Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.
McDannold, Nathan; Vykhodtseva, Natalia; Raymond, Scott; Jolesz, Ferenc A; Hynynen, Kullervo
2005-11-01
Focused ultrasound offers a method to disrupt the blood-brain barrier (BBB) noninvasively and reversibly at targeted locations. The purpose of this study was to test the safety of this method by searching for ischemia and apoptosis in areas with BBB disruption induced by pulsed ultrasound in the presence of preformed gas bubbles and by looking for delayed effects up to one month after sonication. Pulsed ultrasound exposures (sonications) were performed in the brains of 24 rabbits under monitoring by magnetic resonance imaging (MRI) (ultrasound: frequency = 1.63 MHz, burst length = 100 ms, PRF = 1 Hz, duration = 20 s, pressure amplitude 0.7 to 1.0 MPa). Before sonication, an ultrasound contrast agent (Optison, GE Healthcare, Milwaukee, WI, USA) was injected IV. BBB disruption was confirmed with contrast-enhanced MR images. Whole brain histologic examination was performed using haematoxylin and eosin staining for general histology, vanadium acid fuchsin-toluidine blue staining for ischemic neurons and TUNEL staining for apoptosis. The main effects observed were tiny regions of extravasated red blood cells scattered around the sonicated locations, indicating affected capillaries. Despite these vasculature effects, only a few cells in some of the sonicated areas showed evidence for apoptosis or ischemia. No ischemic or apoptotic regions were detected that would indicate a compromised blood supply was induced by the sonications. No delayed effects were observed either by MRI or histology up to 4 wk after sonication. Ultrasound-induced BBB disruption is possible without inducing substantial vascular damage that would result in ischemic or apoptotic death to neurons. These findings indicate that this method is safe for targeted drug delivery, at least when compared with the currently available invasive methods.
An inverse approach to determining spatially varying arterial compliance using ultrasound imaging
NASA Astrophysics Data System (ADS)
Mcgarry, Matthew; Li, Ronny; Apostolakis, Iason; Nauleau, Pierre; Konofagou, Elisa E.
2016-08-01
The mechanical properties of arteries are implicated in a wide variety of cardiovascular diseases, many of which are expected to involve a strong spatial variation in properties that can be depicted by diagnostic imaging. A pulse wave inverse problem (PWIP) is presented, which can produce spatially resolved estimates of vessel compliance from ultrasound measurements of the vessel wall displacements. The 1D equations governing pulse wave propagation in a flexible tube are parameterized by the spatially varying properties, discrete cosine transform components of the inlet pressure boundary conditions, viscous loss constant and a resistance outlet boundary condition. Gradient descent optimization is used to fit displacements from the model to the measured data by updating the model parameters. Inversion of simulated data showed that the PWIP can accurately recover the correct compliance distribution and inlet pressure under realistic conditions, even under high simulated measurement noise conditions. Silicone phantoms with known compliance contrast were imaged with a clinical ultrasound system. The PWIP produced spatially and quantitatively accurate maps of the phantom compliance compared to independent static property estimates, and the known locations of stiff inclusions (which were as small as 7 mm). The PWIP is necessary for these phantom experiments as the spatiotemporal resolution, measurement noise and compliance contrast does not allow accurate tracking of the pulse wave velocity using traditional approaches (e.g. 50% upstroke markers). Results from simulations indicate reflections generated from material interfaces may negatively affect wave velocity estimates, whereas these reflections are accounted for in the PWIP and do not cause problems.
Faria, Alice Fátima Melgaço; de Souza, Marco Aurélio Martins; Geber, Selmo
2011-08-01
The aim of this study was to evaluate the effect of estrogen on the vascular resistance of the central retinal artery in postmenopausal women, compared with placebo, using transorbital ultrasound with Doppler velocimetry. We performed a prospective, randomized, triple-blinded placebo-controlled study. A total of 51 healthy postmenopausal women (follicle-stimulating hormone, >40 IU/L) with a mean (SD) age of 53.6 (4.8) years were studied. Participants were randomly allocated into two groups: placebo (n = 23) and estrogen (0.625 mg conjugated estrogens; n = 28). Transorbital Doppler velocimetric ultrasound was performed before and after treatment in sitting and supine positions. The mean age was similar in both groups. The pulsatility index of the central retinal arteries had a significant decrease after the use of estrogen, when women were evaluated in the sitting position. Women who received placebo did not show any difference in pulsatility index of the central retinal arteries after treatment. When the same comparison was done with participants in the supine position, no difference was observed in either group. Our study demonstrates that estrogen reduces the vascular resistance of the central retinal artery in postmenopausal women because of a vasodilatory effect.
NASA Astrophysics Data System (ADS)
Chang, Bingguo; Chen, Xiaofei
2018-05-01
Ultrasonography is an important examination for the diagnosis of chronic liver disease. The doctor gives the liver indicators and suggests the patient's condition according to the description of ultrasound report. With the rapid increase in the amount of data of ultrasound report, the workload of professional physician to manually distinguish ultrasound results significantly increases. In this paper, we use the spectral clustering method to cluster analysis of the description of the ultrasound report, and automatically generate the ultrasonic diagnostic diagnosis by machine learning. 110 groups ultrasound examination report of chronic liver disease were selected as test samples in this experiment, and the results were validated by spectral clustering and compared with k-means clustering algorithm. The results show that the accuracy of spectral clustering is 92.73%, which is higher than that of k-means clustering algorithm, which provides a powerful ultrasound-assisted diagnosis for patients with chronic liver disease.
A single FPGA-based portable ultrasound imaging system for point-of-care applications.
Kim, Gi-Duck; Yoon, Changhan; Kye, Sang-Bum; Lee, Youngbae; Kang, Jeeun; Yoo, Yangmo; Song, Tai-kyong
2012-07-01
We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.
Zhang, Junling; Li, Hezhou; Wang, Fang; Qin, Hongyan; Qin, Qiaohong
2018-05-07
The aim of the study described here was to identify an efficient criterion for the prenatal diagnosis of abnormal invasive placenta. We evaluated 129 women with anterior placenta previa who underwent trans-abdominal ultrasound evaluation in the third trimester. Spectral Doppler ultrasonography was performed to assess the subplacental blood flow of the anterior lower uterine segment by measuring the highest peak systolic velocity and resistive index. These patients were prospectively followed until delivery and evaluated for abnormal placental invasion. The peak systolic velocity and resistive index of patients with and without abnormal placental invasion were then compared. Postpartum examination revealed that 55 of the patients had an abnormal invasive placenta, whereas the remaining 74 did not. Patients with abnormal placental invasion had a higher peak systolic velocity of the subplacental blood flow in the lower segment of the anterior aspect of the uterus (area under receiver operating characteristic curve: 0.91; 95% confidence interval: 0.87-0.96) than did those without abnormal placental invasion. Our preliminary investigations suggest that a peak systolic velocity of 41 cm/s can be considered a cutoff point to diagnose abnormal invasive placenta, with both good sensitivity (87%) and good specificity (78%), and the higher the peak systolic velocity, the greater is the chance of abnormal placental invasion. Resistive index had no statistical significance (area under receiver operating characteristic curve, 0.56; 95% confidence interval: 0.46-0.66) in the diagnosis of abnormal invasive placenta. In conclusion, measurement of the highest peak systolic velocity of subplacental blood flow in the anterior lower uterine segment can serve as an additional marker of anterior abnormal invasive placenta. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Guo, Hao; Wang, Ziming; Du, Quanyin; Li, Pan; Wang, Zhigang; Wang, Aimin
2017-01-01
Bacterial biofilms on the surface of prostheses are becoming a rising concern in managing prosthetic joint infections. The inherent resistant features of biofilms render traditional antimicrobial therapy unproductive and revision surgery outcomes uncertain. This situation has prompted the exploration of novel antimicrobial strategies. The synergy of ultrasound microbubbles and vancomycin has been proposed as an efficient alternative for biofilm eradication. The purpose of this study was to evaluate the anti-biofilm effect of stimulated phase-shift acoustic nanodroplets (NDs) combined with vancomycin. We fabricated lipid phase-shift NDs with a core of liquid perfluoropentane. A new phase change mode for NDs incorporating an initial unfocused low-intensity pulsed ultrasound for 5 minutes and a subsequent incubation at 37°C into a 24-hour duration was developed. Methicillin-resistant Staphylococcus aureus (MRSA) biofilms were incubated with vancomycin and NDs under the hybrid stimulation. Biofilm morphology following treatment was determined using confocal laser scanning microscopy and scanning electron microscopy. Resazurin assay was used to quantify bactericidal efficacy against MRSA biofilm bacteria. NDs treated sequentially with ultrasound and heating at 37°C achieved gradual and substantial ND vaporization and cavitation in a successive process. NDs after stimulation were capable of generating stronger destruction on biofilm structure which was best characterized by residual circular arc margins and more dead bacteria. Furthermore, NDs combined with vancomycin contributed to significantly decreasing the metabolic activity of bacteria in MRSA biofilms ( P <0.05). Phase-shift acoustic NDs could exert a significant bactericidal effect against MRSA biofilms through a new stimulation mode. Acoustic NDs present advantages over microbubbles for biofilm damage. This anti-biofilm strategy could be used either alone or as an enhancer of traditional antibiotics in the control of prosthetic joint infections.
[Urodynamics foundations: contractile potency and urethral doppler].
Benítez Navío, Julio; Caballero Gómez, Pilar; Delgado Elipe, Ildefonso
2002-12-01
To calculate the bladder softening factor, elastic constant and contractile potency. For the analysis we considered bladder behavior like that of a spring. See articles 1 and 2 published in this issue. Using flowmetry, Doppler ultrasound and abdominal pressure (Transrectal pressure register catheter) an analytical solution that permits calculation of factors defining bladder behavior was looked for. Doppler ultrasound allows us to know urine velocity through the prostatic urethra and, therefore, to calculate bladder contractile potency. Equations are solved reaching an analytical solution that allows calculating those factors that define bladder behavior: Bladder contractile potency, detrusor elastic constant, considering it behaves like a spring, and calculation of muscle resistance to movement. All thanks to Doppler ultrasound that allows to know urine speed. The bladder voiding phase is defined with the aforementioned factors; storage phase behavior can be indirectly inferred. Only uroflowmetry curves, Doppler ultrasound and abdominal pressure value are used. We comply with the so called non invasive urodynamics although for us it is just another phase in the biomechanical study of the detrusor muscle. Main conclusion is the addition of Doppler ultrasound to the urodynamist armamentarium as an essential instrument for the comprehension of bladder dynamics and calculation of bladder behavior defining factors. It is not a change in the focus but in the methods, gaining knowledge and diminishing invasion.
Multiparametric Quantitative Ultrasound Imaging in Assessment of Chronic Kidney Disease.
Gao, Jing; Perlman, Alan; Kalache, Safa; Berman, Nathaniel; Seshan, Surya; Salvatore, Steven; Smith, Lindsey; Wehrli, Natasha; Waldron, Levi; Kodali, Hanish; Chevalier, James
2017-11-01
To evaluate the value of multiparametric quantitative ultrasound imaging in assessing chronic kidney disease (CKD) using kidney biopsy pathologic findings as reference standards. We prospectively measured multiparametric quantitative ultrasound markers with grayscale, spectral Doppler, and acoustic radiation force impulse imaging in 25 patients with CKD before kidney biopsy and 10 healthy volunteers. Based on all pathologic (glomerulosclerosis, interstitial fibrosis/tubular atrophy, arteriosclerosis, and edema) scores, the patients with CKD were classified into mild (no grade 3 and <2 of grade 2) and moderate to severe (at least 2 of grade 2 or 1 of grade 3) CKD groups. Multiparametric quantitative ultrasound parameters included kidney length, cortical thickness, pixel intensity, parenchymal shear wave velocity, intrarenal artery peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index. We tested the difference in quantitative ultrasound parameters among mild CKD, moderate to severe CKD, and healthy controls using analysis of variance, analyzed correlations of quantitative ultrasound parameters with pathologic scores and the estimated glomerular filtration rate (GFR) using Pearson correlation coefficients, and examined the diagnostic performance of quantitative ultrasound parameters in determining moderate CKD and an estimated GFR of less than 60 mL/min/1.73 m 2 using receiver operating characteristic curve analysis. There were significant differences in cortical thickness, pixel intensity, PSV, and EDV among the 3 groups (all P < .01). Among quantitative ultrasound parameters, the top areas under the receiver operating characteristic curves for PSV and EDV were 0.88 and 0.97, respectively, for determining pathologic moderate to severe CKD, and 0.76 and 0.86 for estimated GFR of less than 60 mL/min/1.73 m 2 . Moderate to good correlations were found for PSV, EDV, and pixel intensity with pathologic scores and estimated GFR. The PSV, EDV, and pixel intensity are valuable in determining moderate to severe CKD. The value of shear wave velocity in assessing CKD needs further investigation. © 2017 by the American Institute of Ultrasound in Medicine.
Genomic damage induced by 1-MHz ultrasound in vitro.
Udroiu, Ion; Marinaccio, Jessica; Bedini, Angelico; Giliberti, Claudia; Palomba, Raffaele; Sgura, Antonella
2018-01-01
Genotoxic effects of therapeutic ultrasound are poorly documented, when compared with the wide use of this physical agent. The aim of this work was to investigate the clastogenic and aneugenic potential of 1 MHz ultrasound, employing intensities (200 and 300 mW/cm 2 ) above the cavitational threshold, but in the range of those normally used in therapeutics. Both normal fibroblasts (AG01522) and tumoral cells (MCF-7) were sonicated. While no effects on viability were noted, significant increases of CREST-negative micronuclei (indicative of clastogenesis) and CREST-positive micronuclei (indicative of aneuploidy) were detected. Clastogenesis was confirmed by increases of γ-H2AX foci, while increases of spindle anomalies confirmed the induction of aneuploidy. Our results confirm previous works that showed ultrasound-induced DNA breakage. Moreover, our experiments show that the known effect of ultrasound-induced damage to microtubules is also able to damage the mitotic spindle and induce aneuploidy. On the overall, this work highlights the importance to further investigate the potential risks related to therapeutics US. Environ. Mol. Mutagen. 59:60-68, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid
2017-05-01
Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.
Xie, Xiangyang; Lin, Wen; Li, Mingyuan; Yang, Yang; Deng, Jianping; Liu, Hui; Chen, Ying; Fu, Xudong; Liu, Hong; Yang, Yanfang
2016-06-01
Because of the absence of tolerable and effective carriers for in vivo delivery, the applications of small interfering RNA (siRNA) in the clinic for therapeutic purposes have been limited. In this study, development of a novel siRNA delivery system based on ultrasound-sensitive nanobubbles (NBs, nano-sized echogenic liposomes) and cell-permeable peptides (CPPs) is described. A CPP-siRNA conjugate was entrapped in an NB, (CPP-siRNA)-NB, and the penetration of CPP-siRNA was temporally masked; local ultrasound stimulation triggered the release of CPP-siRNA from the NBs and activated its penetration. Subsequent research revealed that the (CPP-siRNA)-NBs had a mean particle size of 201 ± 2.05 nm and a siRNA entrapment efficiency >85%. In vitro release results indicated that >90% of the encapsulated CPP-siRNA was released from NBs in the presence of ultrasound, whereas <1.5% (30 min) was released in the absence of ultrasound. Cell experiments indicated higher cellular CPP-siRNA uptake of (CPP-siRNA)-NBs with ultrasound among the various formulations in human breast adenocarcinoma cells (HT-1080). Additionally, after systemic administration in mice, (CPP-siRNA)-NBs accumulated in the tumor, augmented c-myc silencing and delayed tumor progression. In conclusion, the application of (CPP-siRNA)-NBs with ultrasound may constitute an approach to selective targeted delivery of siRNA. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas
2017-06-01
Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.
WFUMB Position Paper. Learning Gastrointestinal Ultrasound: Theory and Practice.
Atkinson, Nathan S S; Bryant, Robert V; Dong, Yi; Maaser, Christian; Kucharzik, Torsten; Maconi, Giovanni; Asthana, Anil K; Blaivas, Michael; Goudie, Adrian; Gilja, Odd Helge; Nolsøe, Christian; Nürnberg, Dieter; Dietrich, Christoph F
2016-12-01
Gastrointestinal ultrasound (GIUS) is an ultrasound application that has been practiced for more than 30 years. Recently, GIUS has enjoyed a resurgence of interest, and there is now strong evidence of its utility and accuracy as a diagnostic tool for multiple indications. The method of learning GIUS is not standardised and may incorporate mentorship, didactic teaching and e-learning. Simulation, using either low- or high-fidelity models, can also play a key role in practicing and honing novice GIUS skills. A course for training as well as establishing and evaluating competency in GIUS is proposed in the manuscript, based on established learning theory practice. We describe the broad utility of GIUS in clinical medicine, including a review of the literature and existing meta-analyses. Further, the manuscript calls for agreement on international standards regarding education, training and indications. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Wolkerstorfer, Silviya V; Rosner, Sabine; Hietz, Peter
2012-10-01
The vulnerability of the xylem to cavitation is an important trait in plant drought resistance and has been quantified by several methods. We present a modified method for the simultaneous measurement of cavitations, recorded as ultrasound acoustic emissions (UAEs), and the water potential, measured with a thermocouple psychrometer, in small samples of conifer wood. Analyzing the amplitude of the individual signals showed that a first phase, during which the mean amplitude increased, was followed by a second phase with distinctly lower signal amplitudes. We provide a method to separate the two groups of signals and show that for many samples plausible vulnerability curves require rejecting late low-energy UAEs. These very likely do not result from cavitations. This method was used to analyze the differences between juvenile wood, and early and late mature wood in Picea abies (L.) Karst. Juvenile earlywood was more resistant to cavitation than mature earlywood or latewood, which we relate to the tracheid anatomy of the samples. Copyright © Physiologia Plantarum 2012.
Can Ultrasound Accurately Assess Ischiofemoral Space Dimensions? A Validation Study.
Finnoff, Jonathan T; Johnson, Adam C; Hollman, John H
2017-04-01
Ischiofemoral impingement is a potential cause of hip and buttock pain. It is evaluated commonly with magnetic resonance imaging (MRI). To our knowledge, no study previously has evaluated the ability of ultrasound to measure the ischiofemoral space (IFS) dimensions reliably. To determine whether ultrasound could accurately measure the IFS dimensions when compared with the gold standard imaging modality of MRI. A methods comparison study. Sports medicine center within a tertiary-care institution. A total of 5 male and 5 female asymptomatic adult subjects (age mean = 29.2 years, range = 23-35 years; body mass index mean = 23.5, range = 19.5-26.6) were recruited to participate in the study. Subjects were secured in a prone position on a MRI table with their hips in a neutral position. Their IFS dimensions were then acquired in a randomized order using diagnostic ultrasound and MRI. The main outcome measurements were the IFS dimensions acquired with ultrasound and MRI. The mean IFS dimensions measured with ultrasound was 29.5 mm (standard deviation [SD] 4.99 mm, standard error mean 1.12 mm), whereas those obtained with MRI were 28.25 mm (SD 5.91 mm, standard error mean 1.32 mm). The mean difference between the ultrasound and MRI measurements was 1.25 mm, which was not statistically significant (SD 3.71 mm, standard error mean 3.71 mm, 95% confidence interval -0.49 mm to 2.98 mm, t 19 = 1.506, P = .15). The Bland-Altman analysis indicated that the 95% limits of agreement between the 2 measurement was -6.0 to 8.5 mm, indicating that there was no systematic bias between the ultrasound and MRI measurements. Our findings suggest that the IFS measurements obtained with ultrasound are very similar to those obtained with MRI. Therefore, when evaluating individuals with suspected ischiofemoral impingement, one could consider using ultrasound to measure their IFS dimensions. III. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Perspectives of high power ultrasound in food preservation
NASA Astrophysics Data System (ADS)
Evelyn; Silva, F. V. M.
2018-04-01
High Power ultrasound can be used to alter physicochemical properties and improve the quality of foods during processing due to a number of mechanical, chemical, and biochemical effects arising from acoustic cavitation. Cavitation creates pressure waves that inactivate microbes and de-agglomerate bacterial clusters or release ascospores from fungal asci. Bacterial and heat resistant fungal spores’ inactivation is a great challenge in food preservation due to their ability to survive after conventional food processing, causing food-borne diseases or spoilage. In this work, a showcase of application of high power ultrasound combined with heat or thermosonication, to inactivate bacterial spores i.e. Bacillus cereus spores in beef slurry and fungal spores i.e. Neosartorya fischeri ascospores in apple juice was presented and compared with thermal processing. Faster inactivation was achieved at higher TS (24 KHz, 0.33 W/g or W/mL) temperatures. Around 2 log inactivation was obtained for B. cereus spores after1 min (70 °C) and N. fischeri ascospores after 30 min (75 °C). Thermal treatments caused <1 log in B. Cereus after 2 min (70 °C) and no inactivation in N. Fischeri ascospores after 30 min (80 °C). In conclusion, temperature plays a significant role for TS spore inactivation and TS was more effective than thermal treatment alone. The mould spores were more resistant than the bacterial spores.
NASA Astrophysics Data System (ADS)
Sim, Jai Kyoung; Hyun, Jaeyub; Doh, Il; Ahn, Bongyoung; Kim, Yong Tae
2018-02-01
A thin-film resistance temperature detector (RTD) array is proposed to measure the temperature distribution inside a phantom. HIFU (high-intensity focused ultrasound) is a non-invasive treatment method using focused ultrasound to heat up a localized region, so it is important to measure the temperature distribution without affecting the ultrasonic field and heat conduction. The present 25 µm thick PI (polyimide) film is transparent not only to an ultrasonic field, because its thickness is much smaller than the wavelength of ultrasound, but also to heat conduction, owing to its negligible thermal mass compared to the phantom. A total of 33 RTDs consisting of Pt resistors and interconnection lines were patterned on a PI substrate using MEMS (microelectromechanical systems) technology, and a polymer phantom was fabricated with the film at the center. The expanded uncertainty of the RTDs was 0.8 K. In the experimental study using a 1 MHz HIFU transducer, the maximum temperature inside the phantom was measured as 70.1 °C just after a HIFU excitation of 6.4 W for 180 s. The time responses of the RTDs at different positions also showed the residual heat transfer inside the phantom after HIFU excitation. HIFU results with the phantom showed that a thin-film RTD array can measure the temperature distribution inside a phantom.
Rich, Kyle T; Hoerig, Cameron L; Rao, Marepalli B; Mast, T Douglas
2014-11-28
Enhanced skin permeability is known to be achieved during sonophoresis due to ultrasound-induced cavitation. However, the mechanistic role of cavitation during sonophoresis has been extensively investigated only for low-frequency (LFS, <100 kHz) applications. Here, mechanisms of permeability-enhancing stable and inertial cavitation were investigated by passively monitoring subharmonic and broadband emissions arising from cavitation isolated within or external to porcine skin in vitro during intermediate- (IFS, 100-700 kHz) and high-frequency sonophoresis (HFS, >1 MHz). The electrical resistance of skin, a surrogate measure of the permeability of skin to a variety of compounds, was measured to quantify the reduction and subsequent recovery of the skin barrier during and after exposure to pulsed (1 second pulse, 20% duty cycle) 0.41 and 2.0 MHz ultrasound over a range of acoustic powers (0-21.7 W) for 30 min. During IFS, significant skin resistance reductions and acoustic emissions from cavitation were measured exclusively when cavitation was isolated outside of the skin. Time-dependent skin resistance reductions measured during IFS correlated significantly with subharmonic and broadband emission levels. During HFS, significant skin resistance reductions were accompanied by significant acoustic emissions from cavitation measured during trials that isolated cavitation activity either outside of skin or within skin. Time-dependent skin resistance reductions measured during HFS correlated significantly greater with subharmonic than with broadband emission levels. The reduction of the skin barrier due to sonophoresis was reversible in all trials; however, effects incurred during IFS recovered more slowly and persisted over a longer period of time than HFS. These results quantitatively demonstrate the significance of cavitation during sonophoresis and suggest that the mechanisms and post-treatment longevity of permeability enhancement due to IFS and HFS treatments are different. Copyright © 2014 Elsevier B.V. All rights reserved.
Imaging nonmelanoma skin cancers with combined ultrasound-photoacoustic microscopy
NASA Astrophysics Data System (ADS)
Sunar, Ulas; Rohrbach, Daniel J.; Morgan, Janet; Zeitouni, Natalie
2013-03-01
PDT has become a treatment of choice especially for the cases with multiple sites and large areas. However, the efficacy of PDT is limited for thicker and deeper tumors. Depth and size information as well as vascularity can provide useful information to clinicians for planning and evaluating PDT. High-resolution ultrasound and photoacoustic imaging can provide information regarding skin structure and vascularity. We utilized combined ultrasound-photoacoustic microscopy for imaging a basal cell carcinoma (BCC) tumor pre-PDT and the results indicate that combined ultrasound-photoacoustic imaging can be useful tool for PDT planning by providing both structural and functional contrasts.
Fischer and Whitson during Sprint Experiment OPS
2017-05-03
iss051e037012 (May 3, 2017) --- Flight engineer Jack Fischer dons Thigh and Calf Guides in preparation for Ultrasound 2 operations for the Integrated Resistance and Aerobic Training Study (Sprint) experiment. He is assisted by Commander Peggy Whitson. Image was taken in the Columbus European Laboratory.
Ma, Xiaobin; Wang, Danli; Yin, Michelle; Lucente, Juliet; Wang, Wenjun; Ding, Tian; Ye, Xingqian; Liu, Donghong
2017-05-01
In this study, ultrasound was applied both during and after the immobilization process and characteristics of different immobilized pectinase samples were studied. When introduced during the immobilization process, ultrasound at an intensity of 9WmL -1 for 20min increased the immobilization yield 92.28% more than the control. When introduced to the already immobilized pectinase, ultrasound at an intensity of 4.5WmL -1 for 10min increased the pectinase activity by 30.05%. Results of scanning electron microscope demonstrated that ultrasound increased surface area and loosened structures of immobilized enzymes. Higher V max and lower K m were obtained after ultrasound treatment, indicating the increased catalytic efficiency and enhanced affinity of immobilized pectinase. Furthermore, the optimum temperature and pH for free and immobilized pectinase remained unchanged at 50°C and pH 4. Thermostability, reaction stability and reusability of two ultrasound-treated pectinase enzymes slightly decreased due to structural matrix changes. Copyright © 2016 Elsevier B.V. All rights reserved.
Diagnostic ultrasound imaging for lateral epicondylalgia: a case-control study.
Heales, Luke James; Broadhurst, Nathan; Mellor, Rebecca; Hodges, Paul William; Vicenzino, Bill
2014-11-01
Lateral epicondylalgia (LE) is clinically diagnosed as pain over the lateral elbow that is provoked by gripping. Usually, LE responds well to conservative intervention; however, those who fail such treatment require further evaluation, including musculoskeletal ultrasound. Previous studies of musculoskeletal ultrasound have methodological flaws, such as lack of assessor blinding and failure to control for participant age, sex, and arm dominance. The purpose of this study was to assess the diagnostic use of blinded ultrasound imaging in people with clinically diagnosed LE compared with that in a control group matched for age, sex, and arm dominance. Participants (30 with LE and 30 controls) underwent clinical examination as the criterion standard test. Unilateral LE was defined as pain over the lateral epicondyle, which was provoked by palpation, resisted wrist and finger extension, and gripping. Controls without symptoms were matched for age, sex, and arm dominance. Ultrasound investigations were performed by two sonographers using a standardized protocol. Grayscale images were assessed for signs of tendon pathology and rated on a four-point ordinal scale. Power Doppler was used to assess neovascularity and rated on a five-point ordinal scale. The combination of grayscale and power Doppler imaging revealed an overall sensitivity of 90% and specificity of 47%. The positive and negative likelihood ratios for combined grayscale and power Doppler imaging were 1.69 and 0.21, respectively. Although ultrasound imaging helps confirm the absence of LE, when findings are negative for tendinopathic changes, the high prevalence of tendinopathic changes in pain-free controls challenges the specificity of the measure. The validity of ultrasound imaging to confirm tendon pathology in clinically diagnosed LE requires further study with strong methodology.
Patel, Pankaj A; Ernst, Frank R; Gunnarsson, Candace L
2012-01-01
Abdominal paracentesis is commonly performed for diagnostic, therapeutic, and palliative indications, but the use of ultrasound guidance for these procedures is relatively recent, variable, and not well documented. A retrospective database analysis of abdominal paracentesis procedures was performed to determine whether ultrasound guidance was associated with differences in adverse events (AEs) or hospital costs, compared to procedures without ultrasound guidance. The hospital database maintained by Premier was used to identify patients with abdominal paracentesis International Classification of Diseases - 9th Revision - Clinical Modification (ICD-9 code 54.9, Common Procedural Terminology CPT-4 codes 49080, 49081) in 2008. Use of ultrasound guidance was determined via patient billing data. The incidence of selected AEs and patients' hospitalization costs were calculated for two groups: procedures with ultrasound guidance and those without. Univariate and multivariable analyses were performed to evaluate differences between groups. This study identified 1297 abdominal paracentesis procedures, 723 (56%) with ultrasound and 574 (44%) without. The indications for paracentesis were similar between the two groups. The incidence of AEs was lower in ultrasound-guided procedures: all AEs (1.4% vs 4.7%, p = 0.01), post-paracentesis infection (0.41% vs 2.44%, p = 0.01), hematoma (0.0% vs 0.87%, p = 0.01), and seroma (0.14% vs 1.05%, p = 0.03). Analyses adjusted for patient and hospital covariates revealed significant reductions in AEs (OR = 0.349, 95% CI = 0.165, 0.739, p = 0.0059) and hospitalization costs ($8761 ± $5956 vs $9848 ± $6581, p < 0.001) for procedures with ultrasound guidance vs those without. There are several limitations to using claims data for clinical analyses; causality cannot be determined, the possibility of miscoded or missing data, and the inability to control for elements not captured in claims data that may influence clinical outcomes. The use of ultrasound guidance in abdominal paracentesis procedures is associated with fewer AEs and lower hospitalization costs than procedures where ultrasound is not used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, R; Bruder, R; Schweikard, A
Purpose: To evaluate the proportion of liver SBRT cases in which robotic ultrasound image guidance concurrent with beam delivery can be deployed without interfering with clinically used VMAT beam configurations. Methods: A simulation environment incorporating LINAC, couch, planning CT, and robotic ultrasound guidance hardware was developed. Virtual placement of the robotic ultrasound hardware was guided by a target visibility map rendered on the CT surface. The map was computed on GPU by using the planning CT to simulate ultrasound propagation and attenuation along rays connecting skin surface points to a rasterized imaging target. The visibility map was validated in amore » prostate phantom experiment by capturing live ultrasound images of the prostate from different phantom locations. In 20 liver SBRT patients treated with VMAT, the simulation environment was used to place the robotic hardware and ultrasound probe at imaging locations indicated on the visibility map. Imaging targets were either entire PTV (range 5.9–679.5 ml) or entire GTV (range 0.9–343.4 ml). Presence or absence of mechanical collisions with LINAC, couch, and patient body as well as interferences with treated beams were recorded. Results: For PTV targets, robotic ultrasound guidance without mechanical collision was possible in 80% of the cases and guidance without beam interference was possible in 60% of the cases. For the smaller GTV targets, these proportions were 95% and 85% correspondingly. GTV size (1/20), elongated shape (1/20), and depth (1/20) were the main factors limiting the availability of non-interfering imaging positions. Conclusion: This study indicates that for VMAT liver SBRT, robotic ultrasound tracking of a relevant internal target would be possible in 85% of cases while using treatment plans currently deployed in the clinic. With beam re-planning in accordance with the presence of robotic ultrasound guidance, intra-fractional ultrasound guidance may be an option for 95% of the liver SBRT cases. This project was funded by NIH Grant R41CA174089.« less
Hooley, Regina J; Andrejeva, Liva; Scoutt, Leslie M
2011-03-01
Although mammography is the mainstay of early breast cancer detection, it has known limitations, particularly in women with dense breasts. As a result, additional imaging modalities, including ultrasound and contrast-enhanced magnetic resonance imaging, are also being used to supplement mammography in the early detection of occult breast cancer. This article reviews the indications and efficacy of mammography, ultrasound, and magnetic resonance imaging as both screening and diagnostic tools.
Lung Ultrasound in the Critically Ill Neonate
Lichtenstein, Daniel A; Mauriat, Philippe
2012-01-01
Critical ultrasound is a new tool for first-line physicians, including neonate intensivists. The consideration of the lung as one major target allows to redefine the priorities. Simple machines work better than up-to-date ones. We use a microconvex probe. Ten standardized signs allow a majority of uses: the bat sign (pleural line), lung sliding and the A-line (normal lung surface), the quad sign and sinusoid sign indicating pleural effusion regardless its echogenicity, the tissue-like sign and fractal sign indicating lung consolidation, the B-line artifact and lung rockets (indicating interstitial syndrome), abolished lung sliding with the stratosphere sign, suggesting pneumothorax, and the lung point, indicating pneumothorax. Other signs are used for more sophisticated applications (distinguishing atelectasis from pneumonia for instance...). All these disorders were assessed in the adult using CT as gold standard with sensitivity and specificity ranging from 90 to 100%, allowing to consider ultrasound as a reasonable bedside gold standard in the critically ill. The same signs are found, with no difference in the critically ill neonate. Fast protocols such as the BLUE-protocol are available, allowing immediate diagnosis of acute respiratory failure using seven standardized profiles. Pulmonary edema e.g. yields anterior lung rockets associated with lung sliding, making the B-profile. The FALLS-protocol, inserted in a Limited Investigation including a simple model of heart and vessels, assesses acute circulatory failure using lung artifacts. Interventional ultrasound (mainly, thoracocenthesis) provides maximal safety. Referrals to CT can be postponed. CEURF proposes personnalized bedside trainings since 1990. Lung ultrasound opens physicians to a visual medicine. PMID:23255876
Lung Ultrasound in the Critically Ill Neonate.
Lichtenstein, Daniel A; Mauriat, Philippe
2012-08-01
Critical ultrasound is a new tool for first-line physicians, including neonate intensivists. The consideration of the lung as one major target allows to redefine the priorities. Simple machines work better than up-to-date ones. We use a microconvex probe. Ten standardized signs allow a majority of uses: the bat sign (pleural line), lung sliding and the A-line (normal lung surface), the quad sign and sinusoid sign indicating pleural effusion regardless its echogenicity, the tissue-like sign and fractal sign indicating lung consolidation, the B-line artifact and lung rockets (indicating interstitial syndrome), abolished lung sliding with the stratosphere sign, suggesting pneumothorax, and the lung point, indicating pneumothorax. Other signs are used for more sophisticated applications (distinguishing atelectasis from pneumonia for instance...). All these disorders were assessed in the adult using CT as gold standard with sensitivity and specificity ranging from 90 to 100%, allowing to consider ultrasound as a reasonable bedside gold standard in the critically ill. The same signs are found, with no difference in the critically ill neonate. Fast protocols such as the BLUE-protocol are available, allowing immediate diagnosis of acute respiratory failure using seven standardized profiles. Pulmonary edema e.g. yields anterior lung rockets associated with lung sliding, making the B-profile. The FALLS-protocol, inserted in a Limited Investigation including a simple model of heart and vessels, assesses acute circulatory failure using lung artifacts. Interventional ultrasound (mainly, thoracocenthesis) provides maximal safety. Referrals to CT can be postponed. CEURF proposes personnalized bedside trainings since 1990. Lung ultrasound opens physicians to a visual medicine.
Experimental analysis of behavior in nanobubbles using echograms under ultrasound exposure
NASA Astrophysics Data System (ADS)
Wada, Hikaru; Koido, Jun; Miyazawa, Shinya; Mochizuki, Takashi; Masuda, Kohji; Unga, Johan; Oda, Yusuke; Suzuki, Ryo; Maruyama, Kazuo
2016-07-01
Although we have reported our attempts to actively control microbubbles in flow using acoustic radiation force for future drug delivery systems, the microbubbles we used are not applicable for in vivo experiments. Thus, we examined two types of nanobubble with a drug-retaining function. Because the nanobubbles are invisible in a conventional optical observation, we observed the behavior of nanobubbles using ultrasound images (echograms). First, we found the optimal settings of echography to guarantee the relationship between the brightness variation and lipid concentration of nanobubbles. Then, we derived the destructive coefficient using two types of path under continuous ultrasound exposure of 5 MHz. Results indicate that the controllability is related to the construction of nanobubbles and the spatial distribution of the ultrasound field. We realized that the design of the ultrasound field is important with Bubble A, whereas the frequency of ultrasound emission needs to be discussed with Bubble B.
Sheehan, Scott E; Coburn, John A; Singh, Hardeep; Vanness, David J; Sittig, Dean F; Moberg, D Paul; Safdar, Nasia; Lee, Kenneth S; Brunner, Michael C
2016-07-01
MRI is frequently overused. The aim of this study was to analyze shoulder MRI ordering practices within a capitated health care system and explore the potential effects of shoulder ultrasound substitution. We reviewed medical records of 237 consecutive shoulder MRI examinations performed in 2013 at a Department of Veterans Affairs tertiary care hospital. Using advanced imaging guidelines, we assessed ordering appropriateness of shoulder MRI and estimated the proportion of examinations for which musculoskeletal ultrasound could have been an acceptable substitute, had it been available. We then reviewed MRI findings and assessed if ultrasound with preceding radiograph would have been adequate for diagnosis, based on literature reports of shoulder ultrasound diagnostic performance. Of the 237 examinations reviewed, 106 (45%) were deemed to be inappropriately ordered, most commonly because of an absent preceding radiograph (n = 98; 92%). Nonorthopedic providers had a higher frequency of inappropriate ordering (44%) relative to orthopedic specialists (17%) (P = .016; odds ratio = 3.15, 95% confidence interval = 1.24-8.01). In the 237 examinations, ultrasound could have been the indicated advanced imaging modality for 157 (66%), and most of these (133/157; 85%) could have had all relevant pathologies characterized when combined with radiographs. Regardless of indicated modality, ultrasound could have characterized 80% of all cases ordered by nonorthopedic providers and 50% of cases ordered by orthopedic specialists (P = .007). Advanced shoulder imaging is often not ordered according to published appropriateness criteria. While nonorthopedic provider orders were more likely to be inappropriate, inappropriateness persisted among orthopedic providers. A combined ultrasound and radiograph evaluation strategy could accurately characterize shoulder pathologies for most cases. Published by Elsevier Inc.
Sex Steroids and Bone Health Status in Men
Chin, Kok-Yong; Ima-Nirwana, Soelaiman
2012-01-01
Male osteoporosis is a health problem which deserves more attention as nearly 30% of osteoporotic fractures happen in men aged 50 years and above. Although men do not experience an accelerated bone loss phase and testosterone deficiency is not a universal characteristic for aged men, osteoporosis due to age-related testosterone deficiency does have a negative impact on bone health status of men. Observations from epidemiological studies indicate that elderly men with higher testosterone can preserve their BMD better and thus are less prone to fracture. Observations on men with estrogen resistance or aromatase deficiency indicate that estrogen is equally important in the maintenance of bone health status. This had been validated in several epidemiological studies which found that the relationships between estrogen and bone health indices are significant and sometimes stronger than testosterone. Studies on the relationship between quantitative ultrasound and bone remodeling markers suggest that testosterone and estrogen may have differential effects on bone, but further evidence was needed. In conclusion, both testosterone and estrogen are important in the maintenance of bone health in men. PMID:23150727
Liu, Wen; Cheng, Ruochuan; Ma, Yunhai; Wang, Dan; Su, Yanjun; Diao, Chang; Zhang, Jianming; Qian, Jun; Liu, Jin
2018-05-03
Early preoperative diagnosis of central lymph node metastasis (CNM) is crucial to improve survival rates among patients with papillary thyroid carcinoma (PTC). Here, we analyzed clinical data from 2862 PTC patients and developed a scoring system using multivariable logistic regression and testified by the validation group. The predictive diagnostic effectiveness of the scoring system was evaluated based on consistency, discrimination ability, and accuracy. The scoring system considered seven variables: gender, age, tumor size, microcalcification, resistance index >0.7, multiple nodular lesions, and extrathyroid extension. The area under the receiver operating characteristic curve (AUC) was 0.742, indicating a good discrimination. Using 5 points as a diagnostic threshold, the validation results for validation group had an AUC of 0.758, indicating good discrimination and consistency in the scoring system. The sensitivity of this predictive model for preoperative diagnosis of CNM was 4 times higher than a direct ultrasound diagnosis. These data indicate that the CNM prediction model would improve preoperative diagnostic sensitivity for CNM in patients with papillary thyroid carcinoma.
Kim, Renita S; Gupta, Simi; Lam-Rachlin, Jennifer; Saltzman, Daniel H; Rebarber, Andrei; Fox, Nathan S
2016-11-01
The objective of this study is to estimate the risk of preterm birth in patients with an ultrasound or physical exam indicated cervical cerclage based on the results of fetal fibronectin (fFN) and cervical length (CL) screening. Retrospective cohort of patients with a singleton pregnancy and an ultrasound or physical exam indicated Shirodkar cerclage placed by one maternal-fetal medicine practice from November 2005 to January 2015. Patients routinely underwent serial CL and fFN testing from 22 to 32 weeks. Based on ROC curve analysis, a short CL was defined as ≤15 mm. All fFN and CL results included are from after the cerclage placement. One hundred and four patients were included. Seventy eight (75%) patients had an ultrasound-indicated cerclage and 26 (25%) patients had a physical exam-indicated cerclage. A positive fFN was associate with preterm birth <32 weeks (15.6% versus 4.2%, p = 0.043), <35 weeks (37.5% versus 11.1%, p = 0.002), <37 weeks (65.6% versus 20.8%, p < 0.001), and earlier gestational ages at delivery (35.2 ± 3.9 versus 37.4 ± 2.9, p = 0.001). A short CL was also associated with preterm birth <35 weeks (50.0% versus 11.9%, p < 0.01), preterm birth <37 weeks (55.0% versus 29.8%, p = 0.033), and earlier gestational ages at delivery (34.8 ± 4.1 versus 37.2 ± 3.0, p = 0.004). The risk of preterm birth <32, <35, and <37 weeks increased significantly with the number of abnormal markers. In patients with an ultrasound or physical exam indicated cerclage, a positive fFN and a short CL are both associated with preterm birth. The risk of preterm birth increases with the number of abnormal biomarkers.
Sikka, Suresh C; Hellstrom, Wayne J G; Brock, Gerald; Morales, Antonio Martin
2013-01-01
In-office evaluation of erectile dysfunction by color duplex Doppler ultrasound (CDDU) may benefit the decision-making process in regard to choosing the most appropriate therapy. Unfortunately, there is no uniform standardization in performing CDDU resulting in high variability in data expression and interpretation when comparing results among various centers, especially when conducting multicenter trials. Establishing standard operating procedures (SOPs) is a major step that will help minimize such variability. This SOP describes CDDU procedure with focus on establishing uniformity and normative parameters. Measure intra-arterial diameter, peak systolic velocity, end-diastolic velocity, and resistive index for each cavernosal artery. After initial discussion with the patient about his history and International Index of Erectile Function evaluation describe procedural steps to the patient. Perform the CDDU in a relaxed state, scanning the entire penis (in B-mode image) using a 7.5- to 12-MHz linear array ultrasound probe. An intracorporal injection of a single or combination of vasoactive agents (e.g., prostaglandin E1, phentolamine, and papaverine) is then administered and CDDU performed at various time points, preferably with audiovisual sexual stimulation (AVSS). Monitor penile erection response (tumescence and rigidity) near peak blood flow. Self-stimulation or AVSS leaving the patient alone in room or redosing may be considered to decrease any anxiety and help achieve a maximum rigid erection. Considering the complexity and heterogeneity of CDDU evaluation, this communication will help in standardization and establish uniformity in such data interpretation. When indicated, invasive diagnostic testing involving (i) penile angiography and (ii) cavernosography/cavernosometry to establish veno-occlusive dysfunction may be recommended to facilitate further treatment options. © 2012 International Society for Sexual Medicine.
Auvert, J-F; Chleir, F; Coppé, G; Hamel-Desnos, C; Moraglia, L; Pichot, O
2014-02-01
The quality standards of the French Society for Vascular Medicine for the ultrasound assessment of the superficial venous system of the lower limbs are based on the two following requirements: technical know-how (mastering the use of ultrasound devices and the method of examination); medical know-how (ability to adapt the methods and scope of the examination to its clinical indications and purpose and to rationally analyze and interpret its results). To describe an optimal method of examination in relation to the clinical question and hypothesis; to achieve consistent practice, methods, glossary terminologies and reporting; to provide good practice reference points and to promote a high quality process. The three levels of examination. Their clinical indications and goals. The reference standard examination (level 2) and its variants according to clinical needs. The minimal content of the examination report, the letter to the referring physician (synthesis, conclusion and management suggestions) and iconography. Commented glossary (anatomy, hemodynamics, semiology). Technical basis. Ultrasound devices settings. We discuss of use of Duplex ultrasound for the assessment of the superficial veins of the lower limbs in vascular medicine practice. Copyright © 2014. Published by Elsevier Masson SAS.
Therapeutic Ultrasound Research And Development From An Industrial And Commercial Perspective
NASA Astrophysics Data System (ADS)
Seip, Ralf
2009-04-01
The objective of this paper is to share the challenges and opportunities as viewed from an industrial and commercial perspective that one encounters when performing therapeutic ultrasound research, development, manufacturing, and sales activities. Research in therapeutic ultrasound has become an active field in the last decade, spurred by technological advances in the areas of transducer materials, control electronics, treatment monitoring techniques, an ever increasing number of clinical applications, and private and governmental funding opportunities. The development of devices and methods utilizing therapeutic ultrasound to cure or manage disease is being pursued by startup companies and large established companies alike, driven by the promise of profiting at many levels from this new and disruptive technology. Widespread penetration within the clinical community remains elusive, with current approaches focusing on very specific applications and niche markets. Challenges include difficulties in securing capital to develop the technology and undertake costly clinical trials, a regulatory landscape that varies from country to country, resistance from established practitioners, and difficulties in assembling a team with the right mix of technological savvy and business expertise. Success is possible and increasing, however, as evidenced by several companies, initiatives, and products with measurable benefits to the patient, clinician, and companies alike.
Ometto, Francesco; Quiroga, Gerardo; Pšenička, Pavel; Whitton, Rachel; Jefferson, Bruce; Villa, Raffaella
2014-11-15
Anaerobic digestion (AD) of microalgae is primarily inhibited by the chemical composition of their cell walls containing biopolymers able to resist bacterial degradation. Adoption of pre-treatments such as thermal, thermal hydrolysis, ultrasound and enzymatic hydrolysis have the potential to remove these inhibitory compounds and enhance biogas yields by degrading the cell wall, and releasing the intracellular algogenic organic matter (AOM). This work investigated the effect of four pre-treatments on three microalgae species, and their impact on the quantity of soluble biomass released in the media and thus on the digestion process yields. The analysis of the composition of the soluble COD released and of the TEM images of the cells showed two main degradation actions associated with the processes: (1) cell wall damage with the release of intracellular AOM (thermal, thermal hydrolysis and ultrasound) and (2) degradation of the cell wall constituents with the release of intracellular AOM and the solubilisation of the cell wall biopolymers (enzymatic hydrolysis). As a result of this, enzymatic hydrolysis showed the greatest biogas yield increments (>270%) followed by thermal hydrolysis (60-100%) and ultrasounds (30-60%). Copyright © 2014 Elsevier Ltd. All rights reserved.
Scott, Susan; Harris, Patrick N; Williamson, Deborah A; Liss, Michael A; Doi, Suhail A R; Roberts, Matthew J
2018-07-01
Rectal culture screening for fluoroquinolone (FQ)-resistant Enterobacteriaceae before transrectal ultrasound guided prostate (TRUSPB) biopsy and targeted antibiotic prophylaxis (TAP) may decrease post-TRUSPB infection rates compared to empiric (EAP) regimens. The objective of this study was to evaluate the effectiveness of targeted relative to empiric prophylaxis regimens on rates of infectious complications after TRUSPB and to determine the baseline prevalence of FQ resistance based on prior rectal swabs. An electronic search within literature databases including EMBASE and Web of Science (all databases) for articles assessing TAP as an approach to TRUSPB prophylaxis was conducted. Quality assessment was performed using the Hoy instrument. Meta-analysis was performed using MetaXL 5.3. From 15 studies (eight retrospective and seven prospective) representing 12,320 participants, infectious complication incidence was 3.4% in EAP and 0.8% in TAP patients. The number needed to treat with TAP to avoid one more infection when compared to the EAP group was 39. Effect sizes were homogeneous. Prevalence of FQ resistance showed low (15%) and high (28%) subgroups, likely due to region of origin (within and outside USA, respectively). Rectal culture prior to TRUSPB and use of TAP adjusts for endemic FQ resistance and is associated with less infectious complications and resulting morbidity when compared to EAP. Overtreatment associated with augmented prophylaxis approaches may be reduced as a result. Further prospective assessment and cost-benefit analyses are required before widespread implementation can be recommended.
Costache, Irina Iuliana; Costea, Claudia Florida; Fotea, Vasile; Rusu, Victor Laurian; Aursulesei, Viviana; Al Namat, Razan; Costache, Dan Alexandru; Dumitrescu, Nicoleta; Buzdugă, Cătălin Mihai; Dumitrescu, Gabriela Florenţa; Sava, Anca; Bogdănici, Camelia Margareta
2018-01-01
Resistant hypertension is defined by the inability to maintain within normal limits the blood pressure values of an individual, while he is under treatment with maximal tolerated doses of three antihypertensive agents. One of the most common types of resistant hypertension is renovascular hypertension (RVH), which is caused by the narrowing of the renal arteries, in the context of existing atherosclerotic plaques at that level. We are presenting the case of a hypertensive 56-year-old man admitted in the Clinic of Cardiology for a sudden rise of his blood pressure values, despite undergoing the scheduled treatment. The abdominal bruit discovered at the clinical examination and the hypokalemia, together with the mild impairment of the renal function raised the suspicion of an existing stenosis of the main renal blood vessels. Simple grey scale kidney ultrasound, Doppler ultrasound of the renal arteries, abdominal computed tomography and magnetic resonance angiography of the renal arteries, along with invasive renal angiography demonstrated a smaller right kidney, adrenal incidentalomas, reduced vascular diameter of renal arteries due to atheromatous lesions, thrombosis of the infrarenal segment of the abdominal aorta, and reduced vascular hemodynamics in the same territories. After the renal arteries revascularization and with minimal antihypertensive treatment, the patient had a favorable outcome, with normalization of blood pressure and renal function. Atherosclerotic disease causing renal artery stenosis is essential to be taken into consideration in the etiopathogenesis of resistant hypertension especially because RVH is a potentially curable disease.
Uncertainty evaluation of dead zone of diagnostic ultrasound equipment
NASA Astrophysics Data System (ADS)
Souza, R. M.; Alvarenga, A. V.; Braz, D. S.; Petrella, L. I.; Costa-Felix, R. P. B.
2016-07-01
This paper presents a model for evaluating measurement uncertainty of a feature used in the assessment of ultrasound images: dead zone. The dead zone was measured by two technicians of the INMETRO's Laboratory of Ultrasound using a phantom and following the standard IEC/TS 61390. The uncertainty model was proposed based on the Guide to the Expression of Uncertainty in Measurement. For the tested equipment, results indicate a dead zone of 1.01 mm, and based on the proposed model, the expanded uncertainty was 0.17 mm. The proposed uncertainty model contributes as a novel way for metrological evaluation of diagnostic imaging by ultrasound.
Twedt, Max; Pfeifer, Chase; Thorell, William; Bashford, Greg
2017-03-01
Possible traumatic brain injury victims would greatly benefit from a handheld, noninvasive intracranial pressure (ICP) monitoring tool, which a medic could operate in a remote area. Such a device would also benefit the transport of injured soldiers during en route medical care and critical care air transport. This study demonstrates the use of noninvasive blood flow measurements in the eye by ultrasound as a proxy for ICP. ICP was artificially raised in a porcine model and resultant blood flow change in the ophthalmic artery was measured. In addition, the ultrasound transducer itself was used to compress the eye further altering ophthalmic hemodynamics. Blood flow velocities at a range of applied forces and ICP were compared. It was found that 3.25 N of force applied to the cornea was sufficient to produce significant changes in ophthalmic artery blood dynamics regardless of the ICP value. Specifically, the change in resistivity index (RI) and pulsatility index (PI) as force was applied to the cornea correlated with ICP levels. In multiple animal experiments, the magnitude of PI/RI percent change was inversely related to differences in ICP. Force applied to the cornea at baseline ICP resulted in a 15% increase in PI/RI. Results indicate that as ICP increases, the percent change in PI/RI while force is applied decreases. The consistency of data collected indicates that a trend line developed with this data and from similar experiments could be used as a predictive measurement of ICP. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
Zhang, Qing-An; Wang, Ting-Ting
2017-11-01
In this paper, the effects of ultrasound irradiation were investigated on the evolution of color properties and major phenolic compounds during wine storage. The results indicate that the changing trends of color parameters are very similar in both the ultrasonically-treated and untreated wines, meanwhile the evolutions of malvidin-3-O-glucoside, monomeric flavan-3-ols and phenolic acids also demonstrate some similar patterns in all wines during storage, respectively. In summary, the ultrasound irradiation does not only temporally influence the color characteristics and phenolic compounds of wine, but also have a longer effect on their evolutions during wine storage. Furthermore, the ultrasonically-treated wine had a quicker changing trend than that of the untreated wine regarding the studied parameters. All these results indicate that the ultrasound might be as a feasible and promising novel technology for wineries to produce more red wines with the similar quality as the traditionally-aged wine in a shorter time. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ions in Wine and Their Relation to Electrical Conductivity Under Ultrasound Irradiation.
Yan, Yan-Ying; Zhang, Qing-An; Li, Er-Chun; Zhang, Ya-Feng
2017-09-01
Change in electrical conductivity is considered a potential indicator for the on-line monitoring of wine aging accelerated by ultrasound, as determined in our previous study; however, the exact mechanism of change is currently unclear. In this study, the ion content and the total ionic strength were analyzed by ion-exchange chromatography to investigate the change mechanism of the electrical conductivity of wine under ultrasound irradiation. The results indicate that the changes in wine electrical conductivity during ultrasound treatment correlate with the changes in the cations (Na+, K+, Ca2+, Mg2+, and NH4+) and in the anions from the organic acids (malic acid, citric acid, tartaric acid, oxalic acid, and formic acid) and inorganic acids (Cl-, SO42-, and PO43-), especially for the ionic strength of the wine. Overall, electrical conductivity may be used to reflect the chemical reactions related to wine aging to a certain extent because the reactions can be initiated by the conversion of cations and by the degradation or auxiliary function of organic acids.
Zhang, Lifen; Ye, Xinqian; Ding, Tian; Sun, Xiaoyang; Xu, Yuting; Liu, Donghong
2013-01-01
The effects of ultrasound on the molecular weight of apple pectin were investigated. The structure and rheological properties of the degradation products were also tentatively identified by High Performance Liquid Chromatography-Photodiode Array Detector (HPLC-PAD), Infrared spectroscopy (IR), Nuclear Magnetic Resonance spectroscopy (NMR) and Rheometer. The results indicated that the weight-average molecular weight of apple pectin decreased obviously after ultrasound treatment. The molecular weight of degradation products had a uniform and narrow distribution. Ultrasound intensity and temperature play an important role in the degradation reaction. Degradation kinetics model of apple pectin fitted to 1/M(t) - 1/M(0) = kt from 5 to 45 °C. The degree of methylation of apple pectin reduced according to IR analysis when ultrasound was applied. Ultrasound treatment could not alter the primary structure of apple pectin according to the results determined by HPLC, IR and NMR. Meanwhile, the viscosity of apple pectin was 10(3) times as large as that of ultrasound-treated apple pectin. The ultrasound-treated apple pectin showed predominantly viscous responses (G' < G") over the same frequency range. The results suggested that ultrasound provided a viable alternative method for the modification of pectin. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Töyräs, J.; Rieppo, J.; Nieminen, M. T.; Helminen, H. J.; Jurvelin, J. S.
1999-11-01
Ultrasound may provide a quantitative technique for the characterization of cartilage changes typical of early osteoarthrosis. In this study, specific changes in bovine articular cartilage were induced using collagenase and chondroitinase ABC, enzymes that selectively degrade collagen fibril network and digest proteoglycans, respectively. Changes in cartilage structure and properties were quantified using high frequency ultrasound, microscopic analyses and mechanical indentation tests. The ultrasound reflection coefficient of the physiological saline-cartilage interface (R1) decreased significantly (-96.4%, p<0.01) in the collagenase digested cartilage compared to controls. Also a significantly lower ultrasound velocity (-6.2%, p<0.01) was revealed after collagenase digestion. After chondroitinase ABC digestion, a new acoustic interface at the depth of the enzyme penetration front was detected. Cartilage thickness, as determined with ultrasound, showed a high, linear correlation (R = 0.943, n = 60, average difference 0.073 mm (4.0%)) with the thickness measured by the needle-probe method. Both enzymes induced a significant decrease in the Young's modulus of cartilage (p<0.01). Our results indicate that high frequency ultrasound provides a sensitive technique for the analysis of cartilage structure and properties. Possibly ultrasound may be utilized in vivo as a quantitative probe during arthroscopy.
Universal Head Ultrasound Screening in Full-term Neonates: A Retrospective Analysis of 6771 Infants.
Ballardini, Elisa; Tarocco, Anna; Rosignoli, Chiara; Baldan, Alessandro; Borgna-Pignatti, Caterina; Garani, Giampaolo
2017-06-01
Full-term neonates may have asymptomatic cranial injuries at birth and head ultrasound screening could be useful for early diagnosis. The aim of this study was to assess the prevalence and type of intracranial abnormalities and the usefulness of head ultrasound screening in these infants. Head ultrasound screening was performed on all full-term neonates (gestational age between 37 and 42 weeks), born at Sant'Anna University Hospital of Ferrara, Italy, from June 1, 2008 through May 31, 2013. Ultrasound findings were categorized into three groups: normal, minor, and major anomalies. All full-term neonates (6771) born at our hospital underwent head ultrasound screening. One hundred fourteen of 6771 (1.7%) presented ultrasound abnormalities, whereas 6657 were normal or exhibited insignificant findings. In 101 of 114 (88.6%), abnormalities were minor, and only 13 infants had major abnormalities (0.19% of all full-term newborns). All neonates with major abnormalities presented with either microcephaly or abnormal neurological evaluations. Only one individual with major abnormalities was detected exclusively by ultrasound. The number of significant anomalies detected by head ultrasound screening in asymptomatic full-term neonates born during the study period was low. Therefore, there is no indication for routine general head ultrasound screening in these patients. However, even if low, in neonates who have neurological abnormalities, risk factors or suspected brain malformations, head ultrasound screening may play an important role in the early diagnosis of intracranial anomalies. Copyright © 2017 Elsevier Inc. All rights reserved.
Xu, Tao; Nie, Yongli; Bai, Jiao; Li, Linjun; Yang, Bo; Zheng, Guangmei; Zhang, Jun; Yu, Jianyun; Cheng, Xiongfei; Jiao, Jiao; Jing, Hongxia
2016-12-01
Human 8-oxoguanine DNA glycosylase (OGG1) is a major base excision repair enzyme, and it was reported to suppress the activation of intrinsic apoptotic signaling pathway in response to oxidative stress. In this study, our aim was to investigate the effects of OGG1 downregulation on ultrasound-induced apoptosis in cervical cancer cells. OGG1 expression was silenced by shRNA in the cervical cancer SW756 and CaSki cells. Cell viability was evaluated by MTT assay after OGG1 knockdown following ultrasound treatment. Ultrasound-induced apoptosis was measured by Annexin V-FITC/propidium iodide. Intracellular reactive oxygen species (ROS) production and Ca(2+) concentration were detected using a fluorescent probe, 2',7'-dichlorofluorescin diacetate (DCFH-DA) and a green fluorescent dye fluo-4AM, respectively. Western blotting was used to analyze the expression of Bcl-2, Bax, cleaved caspase-3, and nuclear factor-κB p65 (NF-κB p65). The results indicated that OGG1 knockdown did not suppress cell proliferation, but significantly augmented ultrasound-induced inhibitory effects on the cell viability, and increased ultrasound-induced early apoptosis and late apoptosis and necrosis in the SW756 and CaSki cells when exposure to ultrasound (1MHz) at 1.5W/cm(2) for 30 and 60s. OGG1 knockdown significantly increased intracellular ROS production and Ca(2+) concentration after incubation of 6, 24, and 48h post-ultrasound treatment. The downregulation of Bcl-2 protein and the upregulation of Bax, cleaved caspase-3, and NF-κB p65 protein levels were observed in the shRNA-OGG1 cells and mock-shRNA cells, but no significant change of these protein levels was found between of them. These results indicate that downregulation of OGG1 expression can augment ultrasound-induced apoptosis in cervical cancer cells, which suggests that OGG1 suppression might provide a new insight for ultrasound-induced therapeutic effects on cervical cancer treatment. Copyright © 2016 Elsevier B.V. All rights reserved.
Clinical responses to focused ultrasound applied to women with vulval intraepithelial neoplasia.
Jia, Ying; Wu, Jin; Xu, Man; Tang, Liangdan; Li, Chengzhi; Luo, Ming; Lou, Meng
2014-11-01
Focused ultrasound waves penetrate superficial tissues and are aimed toward the target tissues at specific depths to exert their biological effects. Focused ultrasound has been applied for a number of clinical indications, including vulval dystrophies and low-grade vulval disease. This study aimed to assess the efficacy and safety of focused ultrasound treatment of high-grade vulval intraepithelial neoplasia (VIN). Eighteen women with high-grade VIN were recruited and treated with focused ultrasound. During each posttreatment follow-up, the safety of, side effects of, and clinical responses to focused ultrasound were evaluated by a standardized protocol, including symptoms, clinical appearance, and histologic findings. All patients completed the designed follow-ups. In most cases, superficial mild to moderate swelling and blisters were seen in the focused ultrasound-treated skin but not in adjacent normal skin. Of the 18 patients, 16 showed complete histologic regression and resolution of symptoms 6 months after treatment. Of the other 2 patients, 1 showed complete regression after a second focused ultrasound treatment. The other patient did not respond to the focused ultrasound treatment and underwent a partial vulvectomy 6 months after treatment. None of the patients developed invasive carcinoma of the vulva during the follow-up period. One patient had local pruritus that was not alleviated by anti-inflammatory medication and local care. The complete responses observed in women with high-grade VIN treated by focused ultrasound, together with the preservation of adjacent normal tissue, suggest that focused ultrasound may be considered for treatment of high-grade VIN. © 2014 by the American Institute of Ultrasound in Medicine.
USDA-ARS?s Scientific Manuscript database
An analytical and statistical method has been developed to measure the ultrasound-enhanced bioscouring performance of milligram quantities of endo- and exo-polygalacturonase enzymes obtained from Rhizopus oryzae fungi. UV-Vis spectrophotometric data and a general linear mixed models procedure indic...
The era of ultrasonography during laparoscopic cholecystectomy.
Onders, Raymond P; Hallowell, Peter T
2005-03-01
The use of ultrasound cholangiography during cholecystectomy has been well described. This study was undertaken to assess the use of the umbilical port exclusively for ultrasound and to assess its employment on the use of fluoroscopy resources. In addition, we also looked at the increased use of ultrasound from 2000 to 2004. The use of imaging techniques during all cholecystectomies was analyzed from January 2000 to July 2001 for one surgeon and compared with that surgeon's present use from January 2004 to June 2004. Patient demographics, intraoperative finding, and postoperative results were reviewed. During the first study period, ultrasound was used in 29% of 189 laparoscopic cholecystectomies. During 2004, ultrasound was used in 77% of 66 laparoscopic cholecystectomies. Throughout both periods, fluoroscopy was only used during 6 laparoscopic common bile duct explorations (2.4% of all cases). There were no false-positive or -negative ultrasounds, and there were no bile duct injuries. As experience with ultrasound cholangiography increases, there is little indication for fluoroscopic cholangiography except for rare questions concerning anatomy and during therapeutic maneuvers for common bile duct stones.
Introduction of basic obstetrical ultrasound screening in undergraduate medical education.
Hamza, A; Solomayer, E-F; Takacs, Z; Juhasz-Boes, I; Joukhadar, R; Radosa, J C; Mavrova, R; Marc, W; Volk, T; Meyberg-Solomayer, G
2016-09-01
Teaching ultrasound procedures to undergraduates has recently been proposed to improve the quality of medical education. We address the impact of applying standardized ultrasound teaching to our undergraduates. Medical students received an additional theoretical and practical course involving hands-on ultrasound screening during their mandatory practical training week in obstetrics and gynecology. The students' theoretical knowledge and fetal image recognition skills were tested before and after the course. After the course, the students were asked to answer a course evaluation questionnaire. To standardize the teaching procedure, we used Peyton's 4-Step Approach to teach the skills needed for a German Society of Ultrasound in Medicine Level 1 ultrasound examiner. The multiple-choice question scores after the course showed statistically significant improvement (50 vs. 80 %; P < 0.001). The questionnaire revealed that students were satisfied with the course, felt that it increased their ultrasound knowledge, and indicated that they wanted more sonographic hands-on training in both obstetrics and gynecology and other medical fields. Using practical, hands-on medical teaching is an emerging method for undergraduate education that should be further evaluated, standardized, and developed.
Le Neindre, Aymeric; Mongodi, Silvia; Philippart, François; Bouhemad, Bélaïd
2016-02-01
The use of diagnostic ultrasound by physiotherapists is not a new concept; it is frequently performed in musculoskeletal physiotherapy. Physiotherapists currently lack accurate, reliable, sensitive, and valid measurements for the assessment of the indications and effectiveness of chest physiotherapy. Thoracic ultrasound may be a promising tool for the physiotherapist and could be routinely performed at patients' bedsides to provide real-time and accurate information on the status of pleura, lungs, and diaphragm; this would allow for assessment of lung aeration from interstitial syndrome to lung consolidation with much better accuracy than chest x-rays or auscultation. Diaphragm excursion and contractility may also be assessed by ultrasound. This narrative review refers to lung and diaphragm ultrasound semiology and describes how physiotherapists could use this tool in their clinical decision-making processes in various cases of respiratory disorders. The use of thoracic ultrasound semiology alongside typical examinations may allow for the guiding, monitoring, and evaluating of chest physiotherapy treatments. Thoracic ultrasound is a potential new tool for physiotherapists. Copyright © 2015 Elsevier Inc. All rights reserved.
Ultrasound-guided peripheral nerve blockade.
Chin, Ki Jinn; Chan, Vincent
2008-10-01
The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.
Acousto-defect interaction in irradiated and non-irradiated silicon n+-p structures
NASA Astrophysics Data System (ADS)
Olikh, O. Ya.; Gorb, A. M.; Chupryna, R. G.; Pristay-Fenenkov, O. V.
2018-04-01
The influence of ultrasound on current-voltage characteristics of non-irradiated silicon n+-p structures as well as silicon structures exposed to reactor neutrons or 60Co gamma radiation has been investigated experimentally. It has been found that the ultrasound loading of the n+-p structure leads to the reversible change of shunt resistance, carrier lifetime, and ideality factor. Specifically, considerable acoustically induced alteration of the ideality factor and the space charge region lifetime was observed in the irradiated samples. The experimental results were described by using the models of coupled defect level recombination, Shockley-Read-Hall recombination, and dislocation-induced impedance. The experimentally observed phenomena are associated with the increase in the distance between coupled defects as well as the extension of the carrier capture coefficient of complex point defects and dislocations. It has been shown that divacancies and vacancy-interstitial oxygen pairs are effectively modified by ultrasound in contrast to interstitial carbon-interstitial oxygen complexes.
Gerner, G J; Burton, V J; Poretti, A; Bosemani, T; Cristofalo, E; Tekes, A; Seyfert, D; Parkinson, C; Leppert, M; Allen, M; Huisman, T A G M; Northington, F J; Johnston, M V
2016-03-01
Prior to therapeutic hypothermia (that is, cooling), transfontanellar duplex brain sonography resistive indices (RI) were studied as a bedside non-invasive measures of cerebral hemodynamics in neonates who suffered from hypoxic-ischemic encephalopathy (HIE). We compared pre- and post-cooling RI values and examined the relationships between RI values and specific long-term neurodevelopmental outcomes. Transfontanellar duplex brain sonography, including RI, were obtained for 28 neonates prior to cooling and for 20 neonates following cooling. All RI values were sampled in the anterior cerebral artery at the beginning of each ultrasound study. Neurodevelopmental assessment was conducted between ages 20-32 months with the Mullen Scale of Early Learning. The relationships between pre- and post-cooling RI and cognitive and motor outcomes were studied. Neonates with RI values <0.60 prior to and following cooling were more likely to die or have severe neurodevelopmental disability by ages 20-32 months than those with RI>0.60. Lower RI values were associated with specific neurodevelopmental deficits in motor skill attainment. Pre- and post-cooling transfontanellar duplex brain sonography RI values may be a useful prognostic tool, in conjunction with other clinical information, for neonates diagnosed with HIE. The results of this study suggest that further study of the prognostic value of RI values for short- and long-term outcomes is warranted.
Li, Yongshen; Song, Yunna; Li, Jihui; Li, Yuehai; Li, Ning; Niu, Shuai
2018-04-01
In this article, polyvinyl alcohol/phytic acid polymer (PVA/PA polymer) is synthesized from PVA and PA via the esterification reaction of PVA and PA in the case of acidity and ultrasound irradiation, and PVA/PA polymer sponge is prepared via foaming PVA/PA polymer in the presence of n-pentane and ammonium bicarbonate, and the structure of PVA/PA polymer and the structure, morphology and crystallinity of PVA/PA polymer sponge are characterized, and the thermal stability and surface resistivity of PVA/PA polymer sponge are investigated. Based on these, it has been attested that PVA/PA polymer synthesized under the acidity and ultrasound irradiation and PVA/PA polymer sponge are structured by the chain of PVA and the cricoid PA connected in the form of ether bonds and phosphonate bonds, and the thermal stability of PVA/PA polymer sponge attains 416.5 °C, and the surface resistivity of PVA/PA polymer sponge reaches 5.76 × 10 4 ohms/sq. Copyright © 2017 Elsevier B.V. All rights reserved.
[Evaluation of neonatal prognosis using Doppler velocimeter in cases of a high risk fetus].
Ferchiou-Cherif, M; Zhioua, F; Hafsia, S; Hamdoun, L; Jedoui, A; Slim, R; Meriah, S
1993-01-01
The authors describe the main characteristics of the Doppler method in the early diagnosis of chronic fetal distress, and report their personal results in the study of 51 high risk pregnancies. In their study the fetal doppler ultrasound findings were correlated with birth weight related to gestational age, and neonatal morbidity. The parameters established from the doppler ultrasound assessment were the placenta resistance (calculated from the formula of Pourcelot: R = S-D/S applied to the umbilical artery) and the cerebro-placental index, Rp/Rc, Rc being the index of cerebral arterial resistance. The diagnosis performance of the method appeared very good: the Rp index was found to be highly specific for hypotrophy (85,7%) and for neonatal morbidity (90%), the RCP index adding its own good sensitivity (85% for hypotrophy and 83,3% for neonatal morbidity). The authors conclude upon the interest to study simultaneously the fetal umbilical and cerebral arterial circulations. The pathological significance of the two indexes appears different so that they are to be complementary in the evaluation of fetal distress.
Ultrasound acoustic wave energy transfer and harvesting
NASA Astrophysics Data System (ADS)
Shahab, Shima; Leadenham, Stephen; Guillot, François; Sabra, Karim; Erturk, Alper
2014-04-01
This paper investigates low-power electricity generation from ultrasound acoustic wave energy transfer combined with piezoelectric energy harvesting for wireless applications ranging from medical implants to naval sensor systems. The focus is placed on an underwater system that consists of a pulsating source for spherical wave generation and a harvester connected to an external resistive load for quantifying the electrical power output. An analytical electro-acoustic model is developed to relate the source strength to the electrical power output of the harvester located at a specific distance from the source. The model couples the energy harvester dynamics (piezoelectric device and electrical load) with the source strength through the acoustic-structure interaction at the harvester-fluid interface. Case studies are given for a detailed understanding of the coupled system dynamics under various conditions. Specifically the relationship between the electrical power output and system parameters, such as the distance of the harvester from the source, dimensions of the harvester, level of source strength, and electrical load resistance are explored. Sensitivity of the electrical power output to the excitation frequency in the neighborhood of the harvester's underwater resonance frequency is also reported.
Belcik, J. Todd; Davidson, Brian P.; Xie, Aris; Wu, Melinda D.; Yadava, Mrinal; Qi, Yue; Liang, Sherry; Chon, Chae Ryung; Ammi, Azzdine Y.; Field, Joshua; Harmann, Leanne; Chilian, William M.; Linden, Joel; Lindner, Jonathan R.
2017-01-01
Background Augmentation of tissue blood flow by therapeutic ultrasound is thought to rely on convective shear. Microbubble contrast agents that undergo ultrasound-mediated cavitation markedly amplify these effects. We hypothesized that purinergic signalling is responsible for shear-dependent increases in muscle perfusion during therapeutic cavitation. Methods Unilateral exposure of the proximal hindlimb of mice (with or without ischemia produced by iliac ligation) to therapeutic ultrasound (1.3 MHz, mechanical index 1.3) was performed for ten minutes after intravenous injection of 2×108 lipid microbubbles. Microvascular perfusion was evaluated by low-power contrast ultrasound perfusion imaging. In vivo muscle ATP release and in vitro ATP release from endothelial cells or erythrocytes were assessed by a luciferin-luciferase assay. Purinergic signalling pathways were assessed by studying interventions that either (1) accelerated ATP degradation; (2) inhibited P2Y receptors, adenosine receptors, or KATP channels; or (3) inhibited downstream signalling pathways involving endothelial nitric oxide synthase (eNOS) or prostanoid production (indomethacin). Augmentation in muscle perfusion by ultrasound cavitation was assessed in a proof-of-concept clinical trial in 12 subjects with stable sickle cell disease (SCD). Results Therapeutic ultrasound cavitation increased muscle perfusion by 7-fold in normal mice, reversed tissue ischemia for up to 24 hrs in the murine model of peripheral artery disease, and doubled muscle perfusion in patients with SCD. Augmentation in flow extended well beyond the region of ultrasound exposure. Ultrasound cavitation produced a nearly 40-fold focal and sustained increase in ATP, the source of which included both endothelial cells and erythrocytes. Inhibitory studies indicated that ATP was a critical mediator of flow augmentation that acts primarily through either P2Y receptors or through adenosine produced by ectonucleotidase activity. Combined indomethacin and inhibition of eNOS abolished the effects of therapeutic ultrasound, indicating downstream signalling through both NO and prostaglandins. Conclusions Therapeutic ultrasound using microbubble cavitation to increase muscle perfusion relies on shear-dependent increases in ATP which can act through a diverse portfolio of purinergic signalling pathways. These events can reverse hindlimb ischemia in mice for >24 hours, and increase muscle blood flow in patients with sickle cell disease. Clinical Trial Registration NCT01566890 (https://clinicaltrials.gov/ct2/show/NCT01566890) PMID:28174191
Belcik, J Todd; Davidson, Brian P; Xie, Aris; Wu, Melinda D; Yadava, Mrinal; Qi, Yue; Liang, Sherry; Chon, Chae Ryung; Ammi, Azzdine Y; Field, Joshua; Harmann, Leanne; Chilian, William M; Linden, Joel; Lindner, Jonathan R
2017-03-28
Augmentation of tissue blood flow by therapeutic ultrasound is thought to rely on convective shear. Microbubble contrast agents that undergo ultrasound-mediated cavitation markedly amplify these effects. We hypothesized that purinergic signaling is responsible for shear-dependent increases in muscle perfusion during therapeutic cavitation. Unilateral exposure of the proximal hindlimb of mice (with or without ischemia produced by iliac ligation) to therapeutic ultrasound (1.3 MHz, mechanical index 1.3) was performed for 10 minutes after intravenous injection of 2×10 8 lipid microbubbles. Microvascular perfusion was evaluated by low-power contrast ultrasound perfusion imaging. In vivo muscle ATP release and in vitro ATP release from endothelial cells or erythrocytes were assessed by a luciferin-luciferase assay. Purinergic signaling pathways were assessed by studying interventions that (1) accelerated ATP degradation; (2) inhibited P2Y receptors, adenosine receptors, or K ATP channels; or (3) inhibited downstream signaling pathways involving endothelial nitric oxide synthase or prostanoid production (indomethacin). Augmentation in muscle perfusion by ultrasound cavitation was assessed in a proof-of-concept clinical trial in 12 subjects with stable sickle cell disease. Therapeutic ultrasound cavitation increased muscle perfusion by 7-fold in normal mice, reversed tissue ischemia for up to 24 hours in the murine model of peripheral artery disease, and doubled muscle perfusion in patients with sickle cell disease. Augmentation in flow extended well beyond the region of ultrasound exposure. Ultrasound cavitation produced an ≈40-fold focal and sustained increase in ATP, the source of which included both endothelial cells and erythrocytes. Inhibitory studies indicated that ATP was a critical mediator of flow augmentation that acts primarily through either P2Y receptors or adenosine produced by ectonucleotidase activity. Combined indomethacin and inhibition of endothelial nitric oxide synthase abolished the effects of therapeutic ultrasound, indicating downstream signaling through both nitric oxide and prostaglandins. Therapeutic ultrasound using microbubble cavitation to increase muscle perfusion relies on shear-dependent increases in ATP, which can act through a diverse portfolio of purinergic signaling pathways. These events can reverse hindlimb ischemia in mice for >24 hours and increase muscle blood flow in patients with sickle cell disease. URL: http://clinicaltrials.gov. Unique identifier: NCT01566890. © 2017 American Heart Association, Inc.
Genetic evaluation of Angus cattle for carcass marbling using ultrasound and genomic indicators
USDA-ARS?s Scientific Manuscript database
Objectives were to estimate genetic parameters needed to elucidate the relationships of a molecular breeding value for marbling (MBV), intramuscular fat of yearling bulls measured with ultrasound (IMF) and marbling score of harvested steers (MRB), and to assess the utility of MBV and IMF in predicti...
Guo, Xin; Ye, Xingqian; Sun, Yujing; Wu, Dan; Wu, Nian; Hu, Yaqin; Chen, Shiguo
2014-02-05
The effects of ultrasound on the molecular weight, structure, and antioxidant potential of a fucoidan found in Isostichopus badionotus were investigated. The results showed the molecular weight (Mw) of fucoidan decreased obviously after ultrasound treatment. Higher ultrasonic intensity, lower temperature, and lower fucoidan concentrations led to a more effective sonochemical effect. The kinetic model for fucoidan degradation fitted to 1/M(wt)-1/M(w0) = kt at the tested temperature. The optimized degradation conditions by response surface methodology (RSM) were temperature, 12 °C, and intensity, 508 W/cm². Structural analysis by FTIR and NMR indicated the fucoidan kept the linear tetrasaccharide repeating units as the original polysaccharides after the ultrasound treatment, with only slight destruction of the middle nonsulfated fucose units. Antioxidant activity assay showed the antioxidant activity was slightly improved by the ultrasound treatment. The results suggested that ultrasound treatment is an effective approach to decrease the M(w) of fucoidan with only minor structural destruction.
Mechanotransduction of Ultrasound is Frequency Dependent Below the Cavitation Threshold
Louw, Tobias M.; Budhiraja, Gaurav; Viljoen, Hendrik J.; Subramanian, Anuradha
2013-01-01
This study provides evidence that low-intensity ultrasound directly affects nuclear processes, and the magnitude of the effect varies with frequency. In particular, we show that the transcriptional induction of first load-inducible genes, which is independent of new protein synthesis, is frequency dependent. Bovine chondrocytes were exposed to low-intensity below the cavitational threshold) ultrasound at 2,5 and 8 MHz. Ultrasound elevated the expression of early response genes c-Fos, c-Jun and c-Myc, maximized at 5 MHz. The phosphorylated ERK inhibitor PD98059 abrogated any increase in c-series gene expression, suggesting that signaling occurs via the MAPPK/ERK pathway. However, phosphorylated ERK levels did not change with ultrasound frequency, indicating that processes downstream of ERK phosphorylation (such as nuclear transport and chromatin reorganization) respond to ultrasound with frequency dependence. A quantitative, biphasic mathematical model based on Biot theory predicted that cytoplasmic and nuclear stress is maximized at 5.2 ± 0.8 MHz for a chondrocyte, confirming experimental measurements. PMID:23562015
Chang, Li-Wen; Hou, Mei-Ling; Hung, Shuo-Hui; Lin, Lie-Chwen; Tsai, Tung-Hu
2015-01-01
Bubble formulations have both diagnostic and therapeutic applications. However, research on nanobubbles/nanodroplets remains in the initial stages. In this study, a nanodroplet formulation was prepared and loaded with a novel class of chemotherapeutic drug, ie, quercetin, to observe its pharmacokinetic properties and ultrasonic bioimaging of specific sites, namely the abdominal vein and bladder. Four parallel groups were designed to investigate the effects of ultrasound and nanodroplets on the pharmacokinetics of quercetin. These groups were quercetin alone, quercetin triggered with ultrasound, quercetin-encapsulated in nanodroplets, and quercetin encapsulated in nanodroplets triggered with ultrasound. Spherical vesicles with a mean diameter of 280 nm were formed, and quercetin was completely encapsulated within. In vivo ultrasonic imaging confirmed that the nanodroplets could be treated by ultrasound. The results indicate that the initial 5-minute serum concentration, area under the concentration–time curve, elimination half-life, and clearance of quercetin were significantly enhanced by nanodroplets with or without ultrasound. PMID:25945049
Lung ultrasound in the critically ill.
Lichtenstein, Daniel A
2014-01-09
Lung ultrasound is a basic application of critical ultrasound, defined as a loop associating urgent diagnoses with immediate therapeutic decisions. It requires the mastery of ten signs: the bat sign (pleural line), lung sliding (yielding seashore sign), the A-line (horizontal artifact), the quad sign, and sinusoid sign indicating pleural effusion, the fractal, and tissue-like sign indicating lung consolidation, the B-line, and lung rockets indicating interstitial syndrome, abolished lung sliding with the stratosphere sign suggesting pneumothorax, and the lung point indicating pneumothorax. Two more signs, the lung pulse and the dynamic air bronchogram, are used to distinguish atelectasis from pneumonia. All of these disorders were assessed using CT as the "gold standard" with sensitivity and specificity ranging from 90% to 100%, allowing ultrasound to be considered as a reasonable bedside "gold standard" in the critically ill. The BLUE-protocol is a fast protocol (<3 minutes), which allows diagnosis of acute respiratory failure. It includes a venous analysis done in appropriate cases. Pulmonary edema, pulmonary embolism, pneumonia, chronic obstructive pulmonary disease, asthma, and pneumothorax yield specific profiles. Pulmonary edema, e.g., yields anterior lung rockets associated with lung sliding, making the "B-profile." The FALLS-protocol adapts the BLUE-protocol to acute circulatory failure. It makes sequential search for obstructive, cardiogenic, hypovolemic, and distributive shock using simple real-time echocardiography (right ventricle dilatation, pericardial effusion), then lung ultrasound for assessing a direct parameter of clinical volemia: the apparition of B-lines, schematically, is considered as the endpoint for fluid therapy. Other aims of lung ultrasound are decreasing medical irradiation: the LUCIFLR program (most CTs in ARDS or trauma can be postponed), a use in traumatology, intensive care unit, neonates (the signs are the same than in adults), many disciplines (pulmonology, cardiology…), austere countries, and a help in any procedure (thoracentesis). A 1992, cost-effective gray-scale unit, without Doppler, and a microconvex probe are efficient. Lung ultrasound is a holistic discipline for many reasons (e.g., one probe, perfect for the lung, is able to scan the whole-body). Its integration can provide a new definition of priorities. The BLUE-protocol and FALLS-protocol allow simplification of expert echocardiography, a clear advantage when correct cardiac windows are missing.
Lung ultrasound in the critically ill
2014-01-01
Lung ultrasound is a basic application of critical ultrasound, defined as a loop associating urgent diagnoses with immediate therapeutic decisions. It requires the mastery of ten signs: the bat sign (pleural line), lung sliding (yielding seashore sign), the A-line (horizontal artifact), the quad sign, and sinusoid sign indicating pleural effusion, the fractal, and tissue-like sign indicating lung consolidation, the B-line, and lung rockets indicating interstitial syndrome, abolished lung sliding with the stratosphere sign suggesting pneumothorax, and the lung point indicating pneumothorax. Two more signs, the lung pulse and the dynamic air bronchogram, are used to distinguish atelectasis from pneumonia. All of these disorders were assessed using CT as the “gold standard” with sensitivity and specificity ranging from 90% to 100%, allowing ultrasound to be considered as a reasonable bedside “gold standard” in the critically ill. The BLUE-protocol is a fast protocol (<3 minutes), which allows diagnosis of acute respiratory failure. It includes a venous analysis done in appropriate cases. Pulmonary edema, pulmonary embolism, pneumonia, chronic obstructive pulmonary disease, asthma, and pneumothorax yield specific profiles. Pulmonary edema, e.g., yields anterior lung rockets associated with lung sliding, making the “B-profile.” The FALLS-protocol adapts the BLUE-protocol to acute circulatory failure. It makes sequential search for obstructive, cardiogenic, hypovolemic, and distributive shock using simple real-time echocardiography (right ventricle dilatation, pericardial effusion), then lung ultrasound for assessing a direct parameter of clinical volemia: the apparition of B-lines, schematically, is considered as the endpoint for fluid therapy. Other aims of lung ultrasound are decreasing medical irradiation: the LUCIFLR program (most CTs in ARDS or trauma can be postponed), a use in traumatology, intensive care unit, neonates (the signs are the same than in adults), many disciplines (pulmonology, cardiology…), austere countries, and a help in any procedure (thoracentesis). A 1992, cost-effective gray-scale unit, without Doppler, and a microconvex probe are efficient. Lung ultrasound is a holistic discipline for many reasons (e.g., one probe, perfect for the lung, is able to scan the whole-body). Its integration can provide a new definition of priorities. The BLUE-protocol and FALLS-protocol allow simplification of expert echocardiography, a clear advantage when correct cardiac windows are missing. PMID:24401163
NASA Astrophysics Data System (ADS)
McDannold, N.; Vykhodtseva, N.; Hynynen, K.
2006-02-01
Acoustic emission was monitored during focused ultrasound exposures in conjunction with an ultrasound contrast agent (Optison®) in order to determine if cavitation activity is associated with the induction of blood-brain barrier disruption (BBBD). Thirty-four locations were sonicated (frequency: 260 kHz) at targets 10 mm deep in rabbit brain (N = 9). The sonications were applied at peak pressure amplitudes ranging from 0.11 to 0.57 MPa (burst length: 10 ms; repetition frequency of 1 Hz; duration: 20 s). Acoustic emission was recorded with a focused passive cavitation detector. This emission was recorded at each location during sonications with and without Optison®. Detectable wideband acoustic emission was observed only at 0.40 and 0.57 MPa. BBBD was observed in contrast MRI after sonication at 0.29-0.57 MPa. The appearance of small regions of extravasated erythrocytes appeared to be associated with this wideband emission signal. The results thus suggest that BBBD resulting from focused ultrasound pulses in the presence of Optison® can occur without indicators for inertial cavitation in vivo, wideband emission and extravasation. If inertial cavitation is not responsible for the BBBD, other ultrasound/microbubble interactions are likely the source. A significant increase in the emission signal due to Optison® at the second and third harmonics of the ultrasound driving frequency was found to correlate with BBBD and might be useful as an online method to indicate when the disruption occurs.
The Role of Acoustic Cavitation in Ultrasound-triggered Drug Release from Echogenic Liposomes
NASA Astrophysics Data System (ADS)
Kopechek, Jonathan A.
Cardiovascular disease (CVD) is the leading cause of death in the United States and globally. CVD-related mortality, including coronary heart disease, heart failure, or stroke, generally occurs due to atherosclerosis, a condition in which plaques build up within arterial walls, potentially causing blockage or rupture. Targeted therapies are needed to achieve more effective treatments. Echogenic liposomes (ELIP), which consist of a lipid membrane surrounding an aqueous core, have been developed to encapsulate a therapeutic agent and/or gas bubbles for targeted delivery and ultrasound image enhancement. Under certain conditions ultrasound can cause nonlinear bubble growth and collapse, known as "cavitation." Cavitation activity has been associated with enhanced drug delivery across cellular membranes. However, the mechanisms of ultrasound-mediated drug release from ELIP have not been previously investigated. Thus, the objective of this dissertation is to elucidate the role of acoustic cavitation in ultrasound-mediated drug release from ELIP. To determine the acoustic and physical properties of ELIP, the frequency-dependent attenuation and backscatter coefficients were measured between 3 and 30 MHz. The results were compared to a theoretical model by measuring the ELIP size distribution in order to determine properties of the lipid membrane. It was found that ELIP have a broad size distribution and can provide enhanced ultrasound image contrast across a broad range of clinically-relevant frequencies. Calcein, a hydrophilic fluorescent dye, and papaverine, a lipophilic vasodilator, were separately encapsulated in ELIP and exposed to color Doppler ultrasound pulses from a clinical diagnostic ultrasound scanner in a flow system. Spectrophotometric techniques (fluorescence and absorbance measurements) were used to detect calcein or papaverine release. As a positive control, Triton X-100 (a non-ionic detergent) was added to ELIP samples not exposed to ultrasound in order to release encapsulated agents completely. Also, sham samples without Triton X-100 or ultrasound exposure were used as negative controls. Color Doppler ultrasound did not release encapsulated calcein or papaverine from ELIP even though there was a complete loss of echogenicity. In subsequent experiments, calcein and rosiglitazone, a hydrophobic anti-diabetic drug, were separately encapsulated in ELIP and exposed to pulsed Doppler ultrasound in a flow system while monitoring cavitation. Samples were exposed to ultrasound pressures above and below cavitation thresholds. In addition, Triton X-100 was used for positive control samples and sham samples were also tested without ultrasound exposure. Adding Triton X-100 resulted in complete release of encapsulated calcein or rosiglitzone. However, Doppler ultrasound exposure did not induce calcein or rosiglitazone release from ELIP in the flow system even when there was persistent cavitation activity and a loss of echogenicity. The results of this dissertation indicate that cavitation of encapsulated bubbles in ELIP solutions is not sufficient to induce drug release. It is possible that ultrasoundmediated thermal processes may have a stronger effect on ELIP permeability than cavitation activity. Perhaps ultrasound-triggered drug release will be possible by improving the ELIP formulation or encapsulating a different gas instead of air. However, cavitation is not a reliable indicator of ultrasound-mediated drug release with the ELIP formulations used in this dissertation.
Pruzan, Alison N; Kaufman, Audrey E; Calcagno, Claudia; Zhou, Yu; Fayad, Zahi A; Mani, Venkatesh
2017-02-28
To demonstrate feasibility of vessel wall imaging of the superficial palmar arch using high frequency micro-ultrasound, 7T and 3T magnetic resonance imaging (MRI). Four subjects (ages 22-50 years) were scanned on a micro-ultrasound system with a 45-MHz transducer (Vevo 2100, VisualSonics). Subjects' hands were then imaged on a 3T clinical MR scanner (Siemens Biograph MMR) using an 8-channel special purpose phased array carotid coil. Lastly, subjects' hands were imaged on a 7T clinical MR scanner (Siemens Magnetom 7T Whole Body Scanner) using a custom built 8-channel transmit receive carotid coil. All three imaging modalities were subjectively analyzed for image quality and visualization of the vessel wall. Results of this very preliminary study indicated that vessel wall imaging of the superficial palmar arch was feasible with a whole body 7T and 3T MRI in comparison with micro-ultrasound. Subjective analysis of image quality (1-5 scale, 1: poorest, 5: best) from B mode, ultrasound, 3T SPACE MRI and 7T SPACE MRI indicated that the image quality obtained at 7T was superior to both 3T MRI and micro-ultrasound. The 3D SPACE sequence at both 7T and 3T MRI with isotropic voxels allowed for multi-planar reformatting of images and allowed for less operator dependent results as compared to high frequency micro-ultrasound imaging. Although quantitative analysis revealed that there was no significant difference between the three methods, the 7T Tesla trended to have better visibility of the vessel and its wall. Imaging of smaller arteries at the 7T is feasible for evaluating atherosclerosis burden and may be of clinical relevance in multiple diseases.
Li, Suyun; Yang, Xue; Zhang, Yanyan; Ma, Haile; Liang, Qiufang; Qu, Wenjuan; He, Ronghai; Zhou, Cunshan; Mahunu, Gustav Komla
2016-07-01
The objectives of this study were to investigate the effects of multi-frequency energy-gathered ultrasound (MFEGU) and MFEGU assisted alkaline pretreatments on the enzymolysis and the mechanism of two pretreatments accelerating the rice protein (RP) proteolysis process. The results showed that MFEGU and MFEGU assisted alkaline pretreatments improved significantly (P<0.05) the degree of hydrolysis (DH) and the protein elution amount of RP. Furthermore under the same DH conditions, ultrasound and ultrasound assisted alkaline pretreatments were more save the enzymolysis time than the unpretreatment. The changes in UV-vis spectra, fluorescence emission spectra indicated unfolding and destruction of RP by MFEGU and MFEGU assisted alkaline pretreatments. The circular dichroism analysis showed that both pretreatments decreased α-helix but increased β-sheet and random coil of RP. Amino acid composition revealed that MFEGU and MFEGU assisted alkaline pretreatments could increase the protein elution amount and the ratio of hydrophobic amino acids. Atomic force microscopy (AFM) indicated that both pretreatments destroyed the microstructures and reduced the particle size of RP. Therefore, MFEGU and MFEGU assisted alkaline pretreatments are beneficial to improving the degree of hydrolysis due to its sonochemistry effect on the molecular conformation as well as on the microstructure of protein. Copyright © 2015 Elsevier B.V. All rights reserved.
Ultrasound for fetal assessment in early pregnancy
Whitworth, Melissa; Bricker, Leanne; Neilson, James P; Dowswell, Therese
2014-01-01
Background Diagnostic ultrasound is a sophisticated electronic technology, which utilises pulses of high frequency sound to produce an image. Diagnostic ultrasound examination may be employed in a variety of specific circumstances during pregnancy such as after clinical complications, or where there are concerns about fetal growth. Because adverse outcomes may also occur in pregnancies without clear risk factors, assumptions have been made that routine ultrasound in all pregnancies will prove beneficial by enabling earlier detection and improved management of pregnancy complications. Routine screening may be planned for early pregnancy, late gestation, or both. The focus of this review is routine early pregnancy ultrasound. Objectives To assess whether routine early pregnancy ultrasound for fetal assessment (i.e. its use as a screening technique) influences the diagnosis of fetal malformations, multiple pregnancies, the rate of clinical interventions, and the incidence of adverse fetal outcome when compared with the selective use of early pregnancy ultrasound (for specific indications). Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (September 2009). Selection criteria Published, unpublished, and ongoing randomised controlled trials that compared outcomes in women who experienced routine versus selective early pregnancy ultrasound (i.e. less than 24 weeks’ gestation). We have included quasi-randomised trials. Data collection and analysis Two review authors independently extracted data for each included study. We used the Review Manager software to enter and analyse data. Main results Routine/revealed ultrasound versus selective ultrasound/concealed: 11 trials including 37505 women. Ultrasound for fetal assessment in early pregnancy reduces the failure to detect multiple pregnancy by 24 weeks’ gestation (risk ratio (RR) 0.07, 95% confidence interval (CI) 0.03 to 0.17). Routine scan is associated with a reduction in inductions of labour for ‘post term’ pregnancy (RR 0.59, 95% CI 0.42 to 0.83). Routine scans do not seem to be associated with reductions in adverse outcomes for babies or in health service use by mothers and babies. Long-term follow up of children exposed to scan in utero does not indicate that scans have a detrimental effect on children’s physical or cognitive development. Authors’ conclusions Early ultrasound improves the early detection of multiple pregnancies and improved gestational dating may result in fewer inductions for post maturity. Caution needs to be exercised in interpreting the results of aspects of this review in view of the fact that there is considerable variability in both the timing and the number of scans women received. PMID:20393955
[Occupational risk caused by ultrasound in medicine].
Magnavita, N; Fileni, A
1994-01-01
Ultrasound (US) is extensively used in the medical field for its therapeutic and diagnostic applications. US units are commonly found in hospitals and clinics of all sizes, and a growing number of medical staff such as doctors and nurses are exposed to hand-transmitted ultrasound waves in their work-place. This review discusses the available information on the occupational risk of the operators using diagnostic and therapeutic ultrasound devices. The new occupational groups of medical workers who use ultrasound (diagnostic, surgical, sterilization, and physiotherapeutic) equipment are exposed to contact ultrasound waves. Contact ultrasound -- i.e., no airspace between the energy source and the biological tissue -- is much more hazardous than exposure to airborne ultrasound because air transmits less than one percent of this kind of energy. In spite of being a non-ionizing radiation with an excellent safety record, US is likely to induce some changes in the exposed organ. Recent Russian studies indicate that the hospital workers who have been long exposed to ultrasound at work may develop neurovascular dose-dependent disorders of the peripheral nervous system in the form of the angiodystonic syndrome of vegetative polyneuritis of the hands. In some Scandinavian studies, female physiotherapists (exposed to ultrasound and short waves) exhibit increased rate of spontaneous abortions and congenital malformations, but no definite conclusion can be drawn on the basis of these results alone. Trends in exposure for diagnostic ultrasound equipment over the last two decades show a continuous increase. While there is no reason for alarm, there is a growing need for avoiding unnecessary exposure to medical workers.
Cognitive load predicts point-of-care ultrasound simulator performance.
Aldekhyl, Sara; Cavalcanti, Rodrigo B; Naismith, Laura M
2018-02-01
The ability to maintain good performance with low cognitive load is an important marker of expertise. Incorporating cognitive load measurements in the context of simulation training may help to inform judgements of competence. This exploratory study investigated relationships between demographic markers of expertise, cognitive load measures, and simulator performance in the context of point-of-care ultrasonography. Twenty-nine medical trainees and clinicians at the University of Toronto with a range of clinical ultrasound experience were recruited. Participants answered a demographic questionnaire then used an ultrasound simulator to perform targeted scanning tasks based on clinical vignettes. Participants were scored on their ability to both acquire and interpret ultrasound images. Cognitive load measures included participant self-report, eye-based physiological indices, and behavioural measures. Data were analyzed using a multilevel linear modelling approach, wherein observations were clustered by participants. Experienced participants outperformed novice participants on ultrasound image acquisition. Ultrasound image interpretation was comparable between the two groups. Ultrasound image acquisition performance was predicted by level of training, prior ultrasound training, and cognitive load. There was significant convergence between cognitive load measurement techniques. A marginal model of ultrasound image acquisition performance including prior ultrasound training and cognitive load as fixed effects provided the best overall fit for the observed data. In this proof-of-principle study, the combination of demographic and cognitive load measures provided more sensitive metrics to predict ultrasound simulator performance. Performance assessments which include cognitive load can help differentiate between levels of expertise in simulation environments, and may serve as better predictors of skill transfer to clinical practice.
NASA Astrophysics Data System (ADS)
Li, Guo-Feng; Zhao, Hui-Xia; Zhou, Hui; Yan, Fei; Wang, Jing-Yao; Xu, Chang-Xi; Wang, Cong-Zhi; Niu, Li-Li; Meng, Long; Wu, Song; Zhang, Huai-Ling; Qiu, Wei-Bao; Zheng, Hai-Rong
2016-04-01
Low frequency ultrasound (<1 MHz) has been demonstrated to be a promising approach for non-invasive neuro-stimulation. However, the focal width is limited to be half centimeter scale. Minimizing the stimulation region with higher frequency ultrasound will provide a great opportunity to expand its application. This study first time examines the feasibility of using high frequency (5 MHz) ultrasound to achieve neuro-stimulation in brain, and verifies the anatomical specificity of neuro-stimulation in vivo. 1 MHz and 5 MHz ultrasound stimulation were evaluated in the same group of mice. Electromyography (EMG) collected from tail muscles together with the motion response videos were analyzed for evaluating the stimulation effects. Our results indicate that 5 MHz ultrasound can successfully achieve neuro-stimulation. The equivalent diameter (ED) of the stimulation region with 5 MHz ultrasound (0.29 ± 0.08 mm) is significantly smaller than that with 1 MHz (0.83 ± 0.11 mm). The response latency of 5 MHz ultrasound (45 ± 31 ms) is also shorter than that of 1 MHz ultrasound (208 ± 111 ms). Consequently, high frequency (5 MHz) ultrasound can successfully activate the brain circuits in mice. It provides a smaller stimulation region, which offers improved anatomical specificity for neuro-stimulation in a non-invasive manner.
Leão, Jorge; Brock, Marianna; Castilho, Márcia; Scariot, André; Scariot, Ana; Braga, Wornei
2012-02-01
The purpose of this study was to correlate morphologic and hemodynamic Doppler ultrasound findings as indicators of the degree of inflammation and fibrosis and to diagnose chronic vital hepatitis complications and progression. A prospective, descriptive study of a case series was conducted that analyzed Doppler ultrasound images of the liver and portal system and used the portal vein congestion index, hepatic and splenic artery impedance indices, and the liver vascular index. Of 50 patients positive for antibodies against hepatitis C virus, morphologic changes highlighted increased hepatic parenchyma echogenicity in 24%, and increased gall blander echogenicity and wall thickness in 4%. The most common hemodynamic changes observed were reduced flow velocity in the portal vein trunk in 26%, congestion index changes in 12%, liver vascular index changes in 16%, and splenic and hepatic artery impedance index changes in 14%. These indices were shown to be associated with alanine aminotransferase levels, which suggested that they are important liver damage indicators in the early phase of infection with hepatitis C virus.
Leão, Jorge; Brock, Marianna; Castilho, Márcia; Scariot, André; Scariot, Ana; Braga, Wornei
2012-01-01
The purpose of this study was to correlate morphologic and hemodynamic Doppler ultrasound findings as indicators of the degree of inflammation and fibrosis and to diagnose chronic vital hepatitis complications and progression. A prospective, descriptive study of a case series was conducted that analyzed Doppler ultrasound images of the liver and portal system and used the portal vein congestion index, hepatic and splenic artery impedance indices, and the liver vascular index. Of 50 patients positive for antibodies against hepatitis C virus, morphologic changes highlighted increased hepatic parenchyma echogenicity in 24%, and increased gall blander echogenicity and wall thickness in 4%. The most common hemodynamic changes observed were reduced flow velocity in the portal vein trunk in 26%, congestion index changes in 12%, liver vascular index changes in 16%, and splenic and hepatic artery impedance index changes in 14%. These indices were shown to be associated with alanine aminotransferase levels, which suggested that they are important liver damage indicators in the early phase of infection with hepatitis C virus. PMID:22302863
Calibration and Evaluation of Ultrasound Thermography Using Infrared Imaging.
Hsiao, Yi-Sing; Deng, Cheri X
2016-02-01
Real-time monitoring of the spatiotemporal evolution of tissue temperature is important to ensure safe and effective treatment in thermal therapies including hyperthermia and thermal ablation. Ultrasound thermography has been proposed as a non-invasive technique for temperature measurement, and accurate calibration of the temperature-dependent ultrasound signal changes against temperature is required. Here we report a method that uses infrared thermography for calibration and validation of ultrasound thermography. Using phantoms and cardiac tissue specimens subjected to high-intensity focused ultrasound heating, we simultaneously acquired ultrasound and infrared imaging data from the same surface plane of a sample. The commonly used echo time shift-based method was chosen to compute ultrasound thermometry. We first correlated the ultrasound echo time shifts with infrared-measured temperatures for material-dependent calibration and found that the calibration coefficient was positive for fat-mimicking phantom (1.49 ± 0.27) but negative for tissue-mimicking phantom (-0.59 ± 0.08) and cardiac tissue (-0.69 ± 0.18°C-mm/ns). We then obtained the estimation error of the ultrasound thermometry by comparing against the infrared-measured temperature and revealed that the error increased with decreased size of the heated region. Consistent with previous findings, the echo time shifts were no longer linearly dependent on temperature beyond 45°C-50°C in cardiac tissues. Unlike previous studies in which thermocouples or water bath techniques were used to evaluate the performance of ultrasound thermography, our results indicate that high-resolution infrared thermography is a useful tool that can be applied to evaluate and understand the limitations of ultrasound thermography methods. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Luqmani, Raashid; Lee, Ellen; Singh, Surjeet; Gillett, Mike; Schmidt, Wolfgang A; Bradburn, Mike; Dasgupta, Bhaskar; Diamantopoulos, Andreas P; Forrester-Barker, Wulf; Hamilton, William; Masters, Shauna; McDonald, Brendan; McNally, Eugene; Pease, Colin; Piper, Jennifer; Salmon, John; Wailoo, Allan; Wolfe, Konrad; Hutchings, Andrew
2016-11-01
Giant cell arteritis (GCA) is a relatively common form of primary systemic vasculitis, which, if left untreated, can lead to permanent sight loss. We compared ultrasound as an alternative diagnostic test with temporal artery biopsy, which may be negative in 9-61% of true cases. To compare the clinical effectiveness and cost-effectiveness of ultrasound with biopsy in diagnosing patients with suspected GCA. Prospective multicentre cohort study. Secondary care. A total of 381 patients referred with newly suspected GCA. Sensitivity, specificity and cost-effectiveness of ultrasound compared with biopsy or ultrasound combined with biopsy for diagnosing GCA and interobserver reliability in interpreting scan or biopsy findings. We developed and implemented an ultrasound training programme for diagnosing suspected GCA. We recruited 430 patients with suspected GCA. We analysed 381 patients who underwent both ultrasound and biopsy within 10 days of starting treatment for suspected GCA and who attended a follow-up assessment (median age 71.1 years; 72% female). The sensitivity of biopsy was 39% [95% confidence interval (CI) 33% to 46%], which was significantly lower than previously reported and inferior to ultrasound (54%, 95% CI 48% to 60%); the specificity of biopsy (100%, 95% CI 97% to 100%) was superior to ultrasound (81%, 95% CI 73% to 88%). If we scanned all suspected patients and performed biopsies only on negative cases, sensitivity increased to 65% and specificity was maintained at 81%, reducing the need for biopsies by 43%. Strategies combining clinical judgement (clinician's assessment at 2 weeks) with the tests showed sensitivity and specificity of 91% and 81%, respectively, for biopsy and 93% and 77%, respectively, for ultrasound; cost-effectiveness (incremental net monetary benefit) was £485 per patient in favour of ultrasound with both cost savings and a small health gain. Inter-rater analysis revealed moderate agreement among sonographers (intraclass correlation coefficient 0.61, 95% CI 0.48 to 0.75), similar to pathologists (0.62, 95% CI 0.49 to 0.76). There is no independent gold standard diagnosis for GCA. The reference diagnosis used to determine accuracy was based on classification criteria for GCA that include clinical features at presentation and biopsy results. We have demonstrated the feasibility of providing training in ultrasound for the diagnosis of GCA. Our results indicate better sensitivity but poorer specificity of ultrasound compared with biopsy and suggest some scope for reducing the role of biopsy. The moderate interobserver agreement for both ultrasound and biopsy indicates scope for improving assessment and reporting of test results and challenges the assumption that a positive biopsy always represents GCA. Further research should address the issue of an independent reference diagnosis, standards for interpreting and reporting test results and the evaluation of ultrasound training, and should also explore the acceptability of these new diagnostic strategies in GCA. The National Institute for Health Research Health Technology Assessment programme.
Ibsen, Stuart; Shi, Guixin; Schutt, Carolyn; Shi, Linda; Suico, Kyle-David; Benchimol, Michael; Serra, Viviana; Simberg, Dmitri; Berns, Michael; Esener, Sadik
2014-01-01
Lipid monolayer coated microbubbles are currently being developed to identify vascular regions that express certain surface proteins as part of the new technique of ultrasound molecular imaging. The microbubbles are functionalized with targeting ligands which bind to the desired cells holding the microbubbles in place as the remaining unbound microbubbles are eliminated from circulation. Subsequent scanning with ultrasound can detect the highly reflectant microbubbles that are left behind. The ultrasound scanning and detection process results in the destruction of the microbubble, creating lipid fragments from the monolayer. Here we demonstrate that microbubbles targeted to 4T1 murine breast cancer cells and human umbilical cord endothelial cells leave behind adhered fragments of the lipid monolayer after exposure to ultrasound with peak negative pressures of 0.18 and 0.8 MPa. Most of the observed fragments were large enough to be resistant to receptor mediated endocytosis. The fragments were not observed to incorporate into the lipid membrane of the cell over a period of 96 min. They were not observed to break into smaller pieces or significantly change shape but they were observed to undergo translation and rotation across the cell surface as the cells migrated over the substrate. These large fragments will apparently remain on the surface of the targeted cells for significant periods of time and need to be considered for their potential effects on blood flow through the microcapillaries and potential for immune system recognition. PMID:25059435
Comparison microbial killing efficacy between sonodynamic therapy and photodynamic therapy
NASA Astrophysics Data System (ADS)
Drantantiyas, Nike Dwi Grevika; Astuti, Suryani Dyah; Nasution, Aulia M. T.
2016-11-01
Biofilm is a way used by bacteria to survive from their environmental conditions by forming colony of bacteria. Specific characteristic in biofilm formation is the availability of matrix layer, known as extracellular polymer substance. Treatment using antibiotics may lead bacteria to be to resistant. Other treatments to reduce microbial, like biofilm, can be performed by using photodynamic therapy. Successful of this kind of therapy is induced by penetration of light and photosensitizer into target cells. The sonodynamic therapy offers greater penetrating capability into tissues. This research aimed to use sonodynamic therapy in reducing biofilm. Moreover, it compares also the killing efficacy of photodynamic therapy, sonodynamic therapy, and the combination of both therapeutic schemes (known as sono-photodynamic) to achieve higher microbial killing efficacy. Samples used are Staphylococcus aureus biofilm. Treatments were divided into 4 groups, i.e. group under ultrasound treatment with variation of 5 power levels, group of light treatment with exposure of 75s, group of combined ultrasound-light with variation of ultrasound power levels, and group of combined lightultrasound with variation of ultrasound power levels. Results obtained for each treatment, expressed in % efficacy of log CFU/mL, showed that the treatment of photo-sonodynamic provides greater killing efficacy in comparison to either sonodynamic and sono-photodynamic. The photo-sonodynamic shows also greater efficacy to photodynamic. So combination of light-ultrasound (photo-sonodynamic) can effectively kill microbial biofilm. The combined therapy will provide even better efficacy using exogenous photosensitizer.
Tringali, Giovanni; Bono, Beatrice; Dones, Ivano; Cordella, Roberto; Didato, Giuseppe; Villani, Flavio; Prada, Francesco
2018-05-01
Type II focal cortical dysplasia is the most common malformation of cortical development associated with drug resistant epilepsy and susceptible to surgical resection. Although, at present, advanced imaging modalities are capable of detecting most cortical disorders, it is still a challenge for the surgeon to visualize them intraoperatively. The lack of direct identification between normal brain and subtle dysplastic tissue may explain the poor results in terms of being seizure-free versus other forms of epilepsy. The aim of this study is to compare magnetic resonance imaging (MRI) and intraoperative ultrasound-guided neuronavigation, along with cortical stimulation and acute electrocorticography, as a multimodal surgical approach to cortical dysplasia's tailored resection. Six consecutive patients with type II cortical dysplasia underwent epilepsy surgery by means of MRI/intraoperative ultrasound-guided neuronavigation. Intraoperative cortical stimulation of sensory/motor cortex was performed to localize cortical eloquent areas. Acute electrocorticography was used to identify epileptogenic tissue. These findings were correlated to real-time ultrasound imaging to establish the extent of the resection. Intraoperative ultrasound depicted cortical dysplasias at a higher resolution and accuracy than MRI. Therefore it maximized the extent of the resection. Both postoperative MRIs and pathology documented the extent of the resection in all patients. Seizure-freedom was achieved in 5 cases (Engel class IA), and in 1 patient it was classified as Engel class IB. No postoperative neurological deficits were observed. These results strongly suggest feasibility of ultrasound-guided resection of focal cortical dysplasia. Providing high resolution and accuracy, it allows an easy, real-time discrimination between normal and dysplastic brain. Copyright © 2018 Elsevier Inc. All rights reserved.
A preliminary evaluation of self-made nanobubble in contrast-enhanced ultrasound imaging
NASA Astrophysics Data System (ADS)
Li, Chunfang; Wu, Kaizhi; Li, Jing; Liu, Haijuan; Zhou, Qibing; Ding, Mingyue
2014-03-01
Nanoscale bubbles (nanobubbles) have been reported to improve contrast in tumor-targeted ultrasound imaging due to the enhanced permeation and retention effects at tumor vascular leaks. In this work, a self-made nanobubble ultrasound contrast agent was preliminarily characterized and evaluated in-vitro and in-vivo. Fundamental properties such as morphology appearance, size distribution, zeta potential, bubble concentration (bubble numbers per milliliter contrast agent suspension) and the stability of nanobubbles were assessed by light microscope and particle sizing analysis. Then the concentration intensity curve and time intensity curves (TICs) were acquired by ultrasound imaging experiment in-vitro. Finally, the contrast-enhanced ultrasonography was performed on rat to investigate the procedure of liver perfusion. The results showed that the nanobubbles had good shape and uniform distribution with the average diameter of 507.9 nm, polydispersity index (PDI) of 0.527, and zeta potential of -19.17 mV. Significant contrast enhancement was observed in in-vitro ultrasound imaging, demonstrating that the self-made nanobubbles can enhance the contrast effect of ultrasound imaging efficiently in-vitro. Slightly contrast enhancement was observed in in-vivo ultrasound imaging, indicating that the nanobubbles are not stable enough in-vivo. Future work will be focused on improving the ultrasonic imaging performance, stability, and antibody binding of the nanoscale ultrasound contrast agent.
Impact of Music in Reducing Patient Anxiety During Pediatric Ultrasound
Kesselman, Andrew; Bergen, Michael; Stefanov, Dimitre; Goldfisher, Rachelle; Amodio, John
2016-01-01
The use of noninvasive ultrasound examinations can potentially result in significant anxiety in the pediatric population. The purpose of this study was to assess the influence of music during pediatric ultrasound examinations to reduce anxiety measured by heart rate. A total of 44 patients were recruited; 21 controls and 23 experimental. Each participant was randomized to either music or no music (control) after parental consent was obtained. Pulse oximeters were used to monitor heart rate at 15 second intervals for a total of 1 minute, with mean values calculated prior to entering the procedure room, during the middle of the procedure, and after the procedure was completed. The total scan time was determined from the initial image acquisition until the last image recorded by the ultrasound technologist. At the completion of each procedure, the ultrasound technologist scored the ease of performance for the scan on a subjective scale of 1-10 based on prior experience. When utilizing music during pediatric ultrasounds examinations, our study demonstrated significantly decreased heart rate variability from pre-procedural to post-procedural periods. There was no statistical significant difference in total scan time or ultrasound technologist scoring between the two groups. This study demonstrates that music is an inexpensive and effective means of reducing anxiety during pediatric ultrasound as indicated by heart rate. PMID:27114817
Feyzi, Ali; Rad, Masoud Pezeshki; Ahanchi, Navid; Firoozabadi, Jalil
2015-01-01
Despite the advantages of ultrasound scan, its use as a screening tool in blunt abdominal trauma is controversial. The aim of this study was to evaluate the diagnostic value of early and late ultrasound in patients with blunt abdominal trauma (BAT). In this study which was performed in a level I trauma center, firstly, 2418 patients with BAT had ultrasound (US) examination by two trauma expert radiologists. Results were compared with the best available gold standards such as laparotomy, CT, repeated ultrasound or clinical course follow-up. Then, 400 patients with BAT were examined by a trained residency student. In the first phase, sensitivity, specificity, negative predictive value, positive predictive value and accuracy of ultrasound were 97%, 98.1%, 99.7%, 83% and 98% respectively. In the second phase, they were 97.3%, 97.2%, 97.7%, 96.8% and 97.3% for the early and 98.5%, 97.6%, 98.5%, 97.5% and 98% for the late ultrasound respectively. Results obtained from this study indicate that negative ultrasound findings associated with negative clinical observation virtually exclude abdominal injury, and confirmation by performing other tests is unnecessary. High sensitivity and negative predictive value is achieved if ultrasound is performed by expert trauma radiologist.
Singh, Shuchi; Agarwal, Mayank; Sarma, Shyamali; Goyal, Arun; Moholkar, Vijayanand S
2015-09-01
This paper presents investigations into mechanism of ultrasound assisted bioethanol synthesis using Parthenium hysterophorus biomass through simultaneous saccharification and fermentation (SSF) mode. Approach of coupling experimental results to mathematical model for SSF using Genetic Algorithm based optimization has been adopted. Comparison of model parameters for experiments with mechanical shaking and sonication (10% duty cycle) give an interesting mechanistic account of influence of ultrasound on SSF system. A 4-fold rise in ethanol and cell mass productivity is seen with ultrasound. The analysis reveals following facets of influence of ultrasound on SSF: increase in Monod constant for glucose for cell growth, maximal specific growth rate and inhibition constant of cell growth by glucose and reduction in specific cell death rate. Values of inhibition constant of cell growth by ethanol (K3E), and constants for growth associated (a) and non-growth associated (b) ethanol production remained unaltered with sonication. Beneficial effects of ultrasound are attributed to enhanced cellulose hydrolysis, enhanced trans-membrane transport of substrate and products as well as dilution of the toxic substances due to micro-convection induced by ultrasound. Intrinsic physiological functioning of cells remained unaffected by ultrasound as indicated by unaltered values of K3E, a and b. Copyright © 2015 Elsevier B.V. All rights reserved.
Gutierrez, Mario I; Penilla, Elias H; Leija, Lorenzo; Vera, Arturo; Garay, Javier E; Aguilar, Guillermo
2017-11-01
Therapeutic ultrasound can induce changes in tissues by means of thermal and nonthermal effects. It is proposed for treatment of some brain pathologies such as Alzheimer's, Parkinson's, Huntington's diseases, and cancer. However, cranium highly absorbs ultrasound reducing transmission efficiency. There are clinical applications of transcranial focused ultrasound and implantable ultrasound transducers proposed to address this problem. In this paper, biocompatible materials are proposed for replacing part of the cranium (cranial implants) based on low porosity polycrystalline 8 mol% yttria-stabilized-zirconia (8YSZ) ceramics as acoustic windows for brain therapy. In order to assess the viability of 8YSZ implants to effectively transmit ultrasound, various 8YSZ ceramics with different porosity are tested; their acoustic properties are measured; and the results are validated using finite element models simulating wave propagation to brain tissue through 8YSZ windows. The ultrasound attenuation is found to be linearly dependent on ceramics' porosity. Results for the nearly pore-free case indicate that 8YSZ is highly effective in transmitting ultrasound, with overall maximum transmission efficiency of ≈81%, compared to near total absorption of cranial bone. These results suggest that 8YSZ polycrystals could be suitable acoustic windows for ultrasound brain therapy at 1 MHz. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fisher, James; Steele, James; Campos, Mario H.; Silva, Marcelo H.; Paoli, Antonio; Giessing, Jurgen; Bottaro, Martim
2018-01-01
Background The objective of the present study was to compare the effects of equal-volume resistance training (RT) performed with different training frequencies on muscle size and strength in trained young men. Methods Sixteen men with at least one year of RT experience were divided into two groups, G1 and G2, that trained each muscle group once and twice a week, respectively, for 10 weeks. Elbow flexor muscle thickness (MT) was measured using a B-Mode ultrasound and concentric peak torque of elbow extensors and flexors were assessed by an isokinetic dynamometer. Results ANOVA did not reveal group by time interactions for any variable, indicating no difference between groups for the changes in MT or PT of elbow flexors and extensors. Notwithstanding, MT of elbow flexors increased significantly (3.1%, P < 0.05) only in G1. PT of elbow flexors and extensors did not increase significantly for any group. Discussion The present study suggest that there were no differences in the results promoted by equal-volume resistance training performed once or twice a week on upper body muscle strength in trained men. Only the group performing one session per week significantly increased the MT of their elbow flexors. However, with either once or twice a week training, adaptations appear largely minimal in previously trained males.
Gentil, Paulo; Fisher, James; Steele, James; Campos, Mario H; Silva, Marcelo H; Paoli, Antonio; Giessing, Jurgen; Bottaro, Martim
2018-01-01
The objective of the present study was to compare the effects of equal-volume resistance training (RT) performed with different training frequencies on muscle size and strength in trained young men. Sixteen men with at least one year of RT experience were divided into two groups, G1 and G2, that trained each muscle group once and twice a week, respectively, for 10 weeks. Elbow flexor muscle thickness (MT) was measured using a B-Mode ultrasound and concentric peak torque of elbow extensors and flexors were assessed by an isokinetic dynamometer. ANOVA did not reveal group by time interactions for any variable, indicating no difference between groups for the changes in MT or PT of elbow flexors and extensors. Notwithstanding, MT of elbow flexors increased significantly (3.1%, P < 0.05) only in G1. PT of elbow flexors and extensors did not increase significantly for any group. The present study suggest that there were no differences in the results promoted by equal-volume resistance training performed once or twice a week on upper body muscle strength in trained men. Only the group performing one session per week significantly increased the MT of their elbow flexors. However, with either once or twice a week training, adaptations appear largely minimal in previously trained males.
Pálsdóttir, K; Fischerova, D; Franchi, D; Testa, A; Di Legge, A; Epstein, E
2015-04-01
To determine how various objective two-dimensional (2D) and three-dimensional (3D) ultrasound parameters allow prediction of deep stromal tumor invasion and lymph node involvement, in comparison to subjective ultrasound assessment, in women scheduled for surgery for cervical cancer. This was a prospective multicenter trial including 104 women with cervical cancer at FIGO Stages IA2-IIB, verified histologically. Patients scheduled for surgery underwent a preoperative ultrasound examination. The value of various 2D (size, color score) and 3D (volume, vascular indices) ultrasound parameters was compared to that of subjective assessment in the prediction of deep stromal tumor invasion and lymph node involvement. Histology obtained from radical hysterectomy or trachelectomy and pelvic lymphadenectomy was considered as the gold standard for assessment. All women underwent pelvic lymphadenectomy, with 99 (95%) undergoing subsequent radical surgery; five underwent only pelvic lymphadenectomy because of the presence of a positive sentinel lymph node. Women with deep stromal invasion or lymph node involvement had significantly larger tumors (diameter and volume) but there was no correlation with vascular indices measured on 3D ultrasound. Subjective evaluation was superior (AUC, 0.93; sensitivity, 90.5%; specificity, 97.2%) in the prediction of deep stromal invasion when compared to any objective measurement technique, with maximal tumor diameter at 20.5-mm cut-off (AUC, 0.83; sensitivity, 90.5%; specificity, 61.1%) and 3D tumor volume at 9.1-mm(3) cut-off (AUC, 0.85; sensitivity, 79.4%; specificity, 83.3%) providing the best performance among the objective parameters. Both subjective assessment and objective measurements were poorly predictive of lymph node involvement. In women with cervical cancer, subjective ultrasound evaluation allowed better prediction of deep stromal invasion than did objective measurements; however, neither subjective evaluation nor objective parameters were adequate to predict lymph node involvement. 3D vascular indices were ineffective in the prediction of advanced stages of the disease. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
El-Karaksy, Hanaa M; El-Raziky, Mona S; Fouad, Hanan M; Anwar, Ghada M; El-Mougy, Fatma M; El-Koofy, Nehal M; El-Hennawy, Ahmad M
2015-01-01
The aim of the present study was to determine the association between insulin resistance (IR) and both non-alcoholic fatty liver disease (NAFLD) and metabolic syndrome (MetS) in a group of Egyptian overweight/obese children and adolescents and to evaluate different IR indices in detection of NAFLD. The study included 76 overweight/obese children aged 2-15 years; 52.6% were males. Laboratory analysis included fasting blood glucose, serum insulin, lipid profile, liver biochemical profile, and liver ultrasound. IR was calculated using the following indices; the homeostasis model assessment method (HOMA-IR), the quantitative insulin-sensitivity check index (QUICKI) and hepatic insulin sensitivity. The National Cholesterol Education Program Adult Treatment Panel III criteria were used to estimate prevalence of MetS. Liver biopsy was done when medically indicated and accepted by parents. IR was detected in 43.4% and 34.2% by using QUICKI and HOMA, respectively. MetS was detected in 36.8% and NAFLD was detected in 45.5% among those performing liver biopsy. Cases with NAFLD had more frequent IR than children with normal histology. QUICKI showed significant difference between normal subjects and both steatosis and non-alcoholic steatohepatitis; while HOMA-IR was sensitive in cases with NASH only. MetS was present in 100% of patients with NASH and in 75% of those with steatosis and they were all obese. Patients with NASH had significantly higher ALT than those with normal histology. IR was significantly associated with NAFLD. QUICKI is considered more sensitive than HOMA-IR in differentiating simple steatosis from normal liver histology. Copyright © 2013 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Herbst, Daniel P.
2013-01-01
Abstract: Improvements in micropore arterial line filter designs used for extracorporeal circulation are still needed because microbubbles larger than the rated pore sizes are being detected beyond the filter outlet. Linked to principles governing the function of micropore filters, fluid pressures contained in extracorporeal circuits also influence the behavior of gas bubbles and the extent to which they are carried in a fluid flow. To better understand the relationship between pressure and microbubble behavior, two ex vivo test circuits with and without inline resistance were designed to assess changes in microbubble load with changes in pressure. Ultrasound Doppler probes were used to measure and compare the quality and quantity of microbubbles generated in each test circuit. Analysis of microbubble load was separated into two distinct phases, the time periods during and immediately after bubble generation. Although microbubble number decreased similarly in both test circuits, changes in microbubble volume were significant only in the test circuit with inline resistance. The test circuit with inline resistance also showed a decrease in the rate of volume transferred across each ultrasound Doppler probe and the microbubble number and size range measured in the postbubble generation period. The present research proposes that fluid pressures contained in extracorporeal circuits may be used to affect gases in solution as a possible method to improve microbubble filtration during extracorporeal circulation. PMID:23930378
Herbst, Daniel P
2013-06-01
Improvements in micropore arterial line filter designs used for extracorporeal circulation are still needed because microbubbles larger than the rated pore sizes are being detected beyond the filter outlet. Linked to principles governing the function of micropore filters, fluid pressures contained in extracorporeal circuits also influence the behavior of gas bubbles and the extent to which they are carried in a fluid flow. To better understand the relationship between pressure and microbubble behavior, two ex vivo test circuits with and without inline resistance were designed to assess changes in microbubble load with changes in pressure. Ultrasound Doppler probes were used to measure and compare the quality and quantity of microbubbles generated in each test circuit. Analysis of microbubble load was separated into two distinct phases, the time periods during and immediately after bubble generation. Although microbubble number decreased similarly in both test circuits, changes in microbubble volume were significant only in the test circuit with inline resistance. The test circuit with inline resistance also showed a decrease in the rate of volume transferred across each ultrasound Doppler probe and the microbubble number and size range measured in the postbubble generation period. The present research proposes that fluid pressures contained in extracorporeal circuits may be used to affect gases in solution as a possible method to improve microbubble filtration during extracorporeal circulation.
Whole breast tissue characterization with ultrasound tomography
NASA Astrophysics Data System (ADS)
Duric, Neb; Littrup, Peter; Li, Cuiping; Roy, Olivier; Schmidt, Steve; Seamans, John; Wallen, Andrea; Bey-Knight, Lisa
2015-03-01
A number of clinical trials have shown that screening ultrasound, supplemental to mammography, detects additional cancers in women with dense breasts. However, labor intensity, operator dependence and high recall rates have limited adoption. This paper describes the use of ultrasound tomography for whole-breast tissue stiffness measurements as a first step toward addressing the issue of high recall rates. The validation of the technique using an anthropomorphic phantom is described. In-vivo applications are demonstrated on 13 breast masses, indicating that lesion stiffness correlates with lesion type as expected. Comparison of lesion stiffness measurements with standard elastography was available for 11 masses and showed a strong correlation between the 2 measures. It is concluded that ultrasound tomography can map out the 3 dimensional distribution of tissue stiffness over the whole breast. Such a capability is well suited for screening where additional characterization may improve the specificity of screening ultrasound, thereby lowering barriers to acceptance.
Ultrasound - Aided ejection in micro injection molding
NASA Astrophysics Data System (ADS)
Masato, D.; Sorgato, M.; Lucchetta, G.
2018-05-01
In this work, an ultrasound-aided ejection system was designed and tested for different polymers (PS, COC and POM) and mold topographies. The proposed solution aims at reducing the ejection friction by decreasing the adhesion component of the frictional force, which is controlled by the contact area developed during the filling stage of the injection molding process. The experimental results indicate a positive effect of ultrasound vibration on the friction force values, with a maximum reduction of 16. Moreover, it is demonstrated that the ultrasound effect is strictly related to both polymer selection and mold roughness. The combined effect on the ejection force of mold surface roughness, melt viscosity during filling and polymer elastic modulus at ejection was modeled to the experimental data, in order to demonstrate that the effect of ultrasound vibration on the ejection friction reduction is due to the heating of the contact interface and the consequent reduction of the polymer elastic modulus.
Effect of high power low frequency ultrasound processing on the stability of lycopene.
Oliveira, Valéria S; Rodrigues, Sueli; Fernandes, Fabiano A N
2015-11-01
The stability of lycopene was evaluated after application of high power low frequency ultrasound. The study was carried out on a solution containing pure lycopene to evaluate the direct effect of ultrasound on lycopene and on tomato purée to evaluate the direct and indirect effects of ultrasound application within a food matrix. Power densities ranging from 55 to 5000 W/L and temperatures ranging from 23°C (ambient) to 60°C were evaluated. The experiments on pure lycopene showed that the application of ultrasound did not have any direct effect over lycopene. However, the retention of lycopene in tomato puree has decreased indicating an indirect effect on lycopene stability caused by high concentration of hydrogen peroxide and the activation of peroxidase enzymes leading to the reduction of ascorbic acid and its regenerative action towards lycopene. Copyright © 2015 Elsevier B.V. All rights reserved.
Prenatal stress and hemodynamics in pregnancy: a systematic review.
Levine, Terri A; Alderdice, Fiona A; Grunau, Ruth E; McAuliffe, Fionnuala M
2016-10-01
Maternal prenatal stress is associated with preterm birth, intrauterine growth restriction, and developmental delay. However, the impact of prenatal stress on hemodynamics during pregnancy remains unclear. This systematic review was conducted in order to assess the quality of the evidence available to date regarding the relationship between prenatal stress and maternal-fetal hemodynamics. The PubMed/Medline, EMBASE, PsycINFO, Maternity and Infant Care, Trip, Cochrane Library, and CINAHL databases were searched using the search terms pregnancy; stress; fetus; blood; Doppler; ultrasound. Studies were eligible for inclusion if prenatal stress was assessed with standardized measures, hemodynamics was measured with Doppler ultrasound, and methods were adequately described. A specifically designed data extraction form was used. The methodological quality of included studies was assessed using well-accepted quality appraisal guidelines. Of 2532 studies reviewed, 12 met the criteria for inclusion. Six reported that prenatal stress significantly affects maternal or fetal hemodynamics; six found no significant association between maternal stress and circulation. Significant relationships between prenatal stress and uterine artery resistance (RI) and pulsatility (PI) indices, umbilical artery RI, PI, and systolic/diastolic ratio, fetal middle cerebral artery PI, cerebroplacental ratio, and umbilical vein volume blood flow were found. To date, there is limited evidence that prenatal stress is associated with changes in circulation. More carefully designed studies with larger sample sizes, repeated assessments across gestation, tighter control for confounding factors, and measures of pregnancy-specific stress will clarify this relationship.
NASA Astrophysics Data System (ADS)
Zhang, Haonan; Hu, Zi Zhong; Li, Jia; Mordovanakis, Aghapi G.; Yang, Xinmai; Paulus, Yannis M.; Wang, Xueding
2017-02-01
Retinal and choroidal neovascularization play a pivotal role in the leading causes of blindness including macular degeneration and diabetic retinopathy (DR). Current therapy by focal laser photocoagulation can damage the normal surrounding cells, such as the photoreceptor inner and outer segments which are adjacent to the retinal pigment epithelium (RPE), due to the use of high laser energy and millisecond pulse duration. Therapies with pharmaceutical agents involve systemic administration of drugs, which can cause adverse effects and patients may become drug-resistant. We have developed a noninvasive photo-mediated ultrasound therapy (PUT) technique as a localized antivascular method, and applied it to remove micro blood vessels in the retina. PUT takes advantage of the high native optical contrast among biological tissues, and has the unique capability to self-target microvessels without causing unwanted damages to the surrounding tissues. This technique promotes cavitation activity in blood vessels by synergistically applying nanosecond laser pulses and ultrasound bursts. Through the interaction between cavitation and blood vessel wall, blood clots in microvessels and vasoconstriction can be induced. As a result, microvessels can be occluded. In comparison with other techniques that involves cavitation, both laser and ultrasound energy needed in PUT is significantly lower, and hence improves the safety in therapy.
Analysis of ultrasound pulse-echo images for characterization of muscle disease
NASA Astrophysics Data System (ADS)
Leeman, Sidney; Heckmatt, John Z.
1996-04-01
This study aims to extract quantifiable indices characterizing ultrasound propagation and scattering in skeletal muscle, from data acquired using a real-time linear array scanner in a paediatric muscle clinic, in order to establish early diagnosis of Duchenne muscular dystrophy in young children, as well as to chart the progressive severity of the disease. Approximately 40 patients with gait disorders, aged between 1 and 11 years, were scanned with a real-time linear array ultrasound scanner, at 5 MHz. A control group consisted of approximately 50 boys, in the same age range, with no evidence or history of muscle disease. Results show that ultrasound quantitative methods can provide a tight clustering of normal data, and also provide a basis for charting the degree of change in diseased muscle. The most significant (quantitative) parameters derive from the frequency of the attenuation and the muscle echogenicity. The approach provides a discrimination method that is more sensitive than visual assessment of the corresponding image by even an experienced observer. There are also indications that the need for traumatic muscle biopsy may be obviated in some cases.
[Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].
Jung, E M; Clevert, D A
2018-06-01
Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.
The validity of ultrasound estimation of muscle volumes.
Infantolino, Benjamin W; Gales, Daniel J; Winter, Samantha L; Challis, John H
2007-08-01
The purpose of this study was to validate ultrasound muscle volume estimation in vivo. To examine validity, vastus lateralis ultrasound images were collected from cadavers before muscle dissection; after dissection, the volumes were determined by hydrostatic weighing. Seven thighs from cadaver specimens were scanned using a 7.5-MHz ultrasound probe (SSD-1000, Aloka, Japan). The perimeter of the vastus lateralis was identified in the ultrasound images and manually digitized. Volumes were then estimated using the Cavalieri principle, by measuring the image areas of sets of parallel two-dimensional slices through the muscles. The muscles were then dissected from the cadavers, and muscle volume was determined via hydrostatic weighing. There was no statistically significant difference between the ultrasound estimation of muscle volume and that estimated using hydrostatic weighing (p > 0.05). The mean percentage error between the two volume estimates was 0.4% +/- 6.9. Three operators all performed four digitizations of all images from one randomly selected muscle; there was no statistical difference between operators or trials and the intraclass correlation was high (>0.8). The results of this study indicate that ultrasound is an accurate method for estimating muscle volumes in vivo.
Cardiometabolic Risk and Female Sexuality: Focus on Clitoral Vascular Resistance.
Maseroli, Elisa; Fanni, Egidia; Cipriani, Sarah; Scavello, Irene; Pampaloni, Francesca; Battaglia, Cesare; Fambrini, Massimiliano; Mannucci, Edoardo; Jannini, Emmanuele A; Maggi, Mario; Vignozzi, Linda
2016-11-01
The relation between sexual and cardiovascular health in women is not well defined. Clitoral color Doppler ultrasound (CDU) with assessment of the pulsatility index (PI), reflecting resistance to blood flow, has been proposed as an objective measurement of sexual functioning. To investigate associations between clitoral PI and cardiometabolic risk factors, sexual and intrapsychic parameters, and self-perception of body image. Seventy-one adult heterosexual women in a stable relationship attending our clinic for sexual dysfunction were consecutively recruited. Patients underwent physical, laboratory, and clitoral color Doppler ultrasound examinations and completed the Female Sexual Function Index, the Middlesex Hospital Questionnaire, and the Body Uneasiness Test (BUT). Clitoral PI was positively correlated with body mass index (r = 0.441, P < .0001), waist circumference (r = 0.474, P < .0001), glycemia (r = 0.300, P = .029), insulin (r = 0.628, P = .002), homeostatic model assessment index (r = 0.605, P = .005), triglycerides (r = 0.340, P = .011), total cholesterol (r = 0.346, P = .010), and low-density lipoprotein cholesterol (r = 0.334, P = .016). All relations, with the exception of glycemia, retained statistical significance after adjusting for age, smoking habit, and years since menopause (P < .0001 for body mass index, waist circumference, and triglycerides; P < .05 for all other associations). Analysis of covariance, after adjusting for confounders, showed that women with obesity or metabolic syndrome (MetS) showed significantly higher PI values (obesity: F = 17.79, P = .001; MetS: F = 7.37, P = .019). In particular, a stepwise increase of PI was found as a function of increasing MetS components (β = 0.434, P = .007). Clitoral PI was negatively associated with Female Sexual Function Index arousal (β = -0.321, P = .014) and satisfaction (β = -0.289, P = .026) scores and positively associated with Middlesex Hospital Questionnaire somatized anxiety symptoms, even after adjusting for age, smoking habit, years since menopause, and current use of psychiatric medication (β = 0.354, P = .011). A positive association also was observed between PI and the BUT positive symptom distress index (β = 0.322, P = .039) and BUT for dislike of the womb, genitals, and breast (β = 0.538, P < .0001; β = 0.642, P < .0001; β = 0.549, P < .0001, respectively). After introducing waist circumference as another covariate, the associations between clitoral PI and the BUT positive symptom distress index and BUT dislike of the womb, genitals, and breast retained statistical significance (P = .038 for positive symptom distress index; P < .0001 for dislike of womb, genitals, and breast). Clitoral vascular resistance is positively associated with MetS (in particular insulin resistance), decreased sexual arousal, body image concerns, and increased somatized anxiety symptoms. Further studies are needed to establish whether treatment of metabolic abnormalities might improve clitoral color Doppler ultrasound indices and sexual outcomes. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Reddy, Uma M; Abuhamad, Alfred Z; Levine, Deborah; Saade, George R
2014-05-01
Given that practice variation exists in the frequency and performance of ultrasound and magnetic resonance imaging in pregnancy, the Eunice Kennedy Shriver National Institute of Child Health and Human Development hosted a workshop to address indications for ultrasound and magnetic resonance imaging in pregnancy, to discuss when and how often these studies should be performed, to consider recommendations for optimizing yield and cost-effectiveness and to identify research opportunities. This article is the executive summary of the workshop. Published by Mosby, Inc.
Reddy, Uma M; Abuhamad, Alfred Z; Levine, Deborah; Saade, George R
2014-05-01
Given that practice variation exists in the frequency and performance of ultrasound and magnetic resonance imaging (MRI) in pregnancy, the Eunice Kennedy Shriver National Institute of Child Health and Human Development hosted a workshop to address indications for ultrasound and MRI in pregnancy, to discuss when and how often these studies should be performed, to consider recommendations for optimizing yield and cost effectiveness, and to identify research opportunities. This article is the executive summary of the workshop.
Reddy, Uma M; Abuhamad, Alfred Z; Levine, Deborah; Saade, George R
2014-05-01
Given that practice variation exists in the frequency and performance of ultrasound and magnetic resonance imaging (MRI) in pregnancy, the Eunice Kennedy Shriver National Institute of Child Health and Human Development hosted a workshop to address indications for ultrasound and MRI in pregnancy, to discuss when and how often these studies should be performed, to consider recommendations for optimizing yield and cost effectiveness, and to identify research opportunities. This article is the executive summary of the workshop.
Using sound for microbial eradication--light at the end of the tunnel?
Harris, Frederick; Dennison, Sarah R; Phoenix, David A
2014-07-01
Sonodynamic antimicrobial chemotherapy (SACT) is a novel modality, which uses ultrasound to kill bacteria by the activation of molecules termed sonosensitisers (SS) to produce reactive oxygen species that are toxic to microorganism although microbial resistance to this modality has been reported. There are a growing number of SS being reported with the dual ability to be activated by both ultrasound and light, and we hypothesis that a novel antimicrobial strategy, potentially known as sonophotodynamic antimicrobial chemotherapy (SPACT), could be developed based on these agents. SPACT offers advantages over SACT and could constitute a new weapon in the fight against the growing global threat posed by microbial infections. © 2014 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.
Crocker, Melissa K.; Stern, Elizabeth A.; Sedaka, Nicole M.; Shomaker, Lauren B.; Brady, Sheila M.; Ali, Asem H.; Shawker, Thomas H.; Hubbard, Van S.
2014-01-01
Context: The effect of obesity and concomitant insulin resistance on pubertal development is incompletely elucidated. Objective: To determine how measures of adiposity and insulin resistance are associated with pubertal maturation in boys and girls. Setting and Design: Breast and pubic hair Tanner stage and testicular volume by orchidometry were determined by physical examination in 1066 children. Ovarian volume was estimated by trans-abdominal ultrasound. Fat mass, skeletal age, and fasting serum for insulin and glucose, total T, estradiol, estrone, dehydroepiandrosterone-sulfate, and androstenedione were measured at the National Institutes of Health Clinical Research Center. Convenience sample; 52% obese, 59% female. Results: Logistic regression identified a significant interaction between sex and obesity for prediction of pubertal development (P ≤ .01). There was a negative association between boys' testicular volume and body mass index (BMI)/fat mass but a positive association between girls' breast stage and BMI/fat mass. Ovarian volume in girls was positively associated with insulin resistance but not with BMI/fat mass. There was a positive association between obesity and measures of estrogen exposure (breast development and skeletal age) in both sexes. Positive correlations were seen for girls between BMI and pubic hair development and between insulin resistance and T production, whereas adiposity was negatively associated with pubic hair in boys. Conclusions: Significant sexual dimorphisms in the manifestations of pubertal development are seen in obese girls and boys. Two known effects of obesity, increased peripheral conversion of low-potency androgens to estrogens by adipose tissue-aromatase and increased insulin resistance, may be in large part responsible for these differences. PMID:24780051
Duboureau, H; Achkar, K; Stephan, R; Schmit, J L; Saint, F
2017-05-01
The biopsies of prostate are the reference examination to assert the diagnosis of prostate cancer. Even if the urinary infectious complications are rare thanks to the systematic oral antibiotic prophylaxis, they may still be serious. The SPILF (Society of Infectious Pathology and French language) published in 2014, an important increase of the resistances in fluoroquinolones for Escherichia coli (3 to 25%), whereas this is the most bacterium frequently found in the urinary infections (70-80%). The objectives of this study were to estimate the indicence of the febrile urinary tract infections after prostate needle biopsy and to define the ecology and the profile of E. coli's resistance. A total of 466 transrectal ultrasound-guided needle prostate biopsy were included in the study from 2012 to 2015. All the patients were taken care according to the recommendations of the AFU (Ouzzane et al., 2011). We estimated, for all the inclusive patients, if they had presented a clinic sign of urinary infection like fever or burning which suggestive of an urinary infection, and having a urines and blood culture, in the next 30 days the realization of the medical exam. Among 466 realized biopsies, seven patients developed a febril urinary tract infection (1.5%) [prostatitis (n=6), orchitis (n=1)]. Five infections to E. coli were identified; two were resistant for fluoroquinolones (40%). No germ was able to be identified for two patients. The infectious complications post-biopsy of prostate are rare (1.5%). E. coli is the germ most frequently identified with 40% of resistance with fluoroquinolones. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Asanidze, E; Khristesashvili, J; Pkhaladze, L; Barbakadze, L
2018-02-01
PCOS has a leading place in women's infertility. Based on the data of recent researches, Anti-Mullerian hormone (AMH) has been considered as one of the diagnostic criteria for PCOS. The aim of study was to determine the correlation of Anti-Mullerian hormone with hormonal and ovarian morphological characteristics in patients with PCOS, with and without insulin resistance. 110 women with diagnosis of PCOS were involved in the study. Patients were divided into two groups: PCOS patients with insulin resistance (60 women) and PCOS patients without insulin resistance (50 women). All patients underwent hormonal investigation (AMH, FSH, LH, T, FT, HOMA- IR, FAI and SHBG). The volume of ovaries and the number of antral follicles (AFC) were determined by ultrasound imaging. Сorrelation between AMH and the ovarian hormonal and morphological characteristics has been shown. In particular, a significant positive correlation between AMH and the volume of the ovaries in both groups was demonstrated. In the group of patients with PCOS and insulin resistance a positive correlation between AMH and the volum of ovary, AFC was shown, as well as a negative correlation between AMH and SHBG. In the same group a tendency of the positive correlation between AMH and TT, HOMA-IR and IRI was seen. In the group of patients with PCOS without insulin resistence a positive correlation between AMH and the volum of ovary was observed, as well as the tendency of positive correlation between AMH and AFC, TT, HOMA-IR, IRI. Additionally, a negative correlation between AMH and SHBG was seen in the later patient group. Increased levels of AMH in all PCOS patients in our study, in comparison with the accepted norm, indicates on possibility of using this data in the diagnosis of PCOS. AMH levels in PCOS patients with and without insulin resistance do not differ significantly. The correlation between AMH and the morphological characteristics of ovaries has been established.
Preparation of cashew gum-based flocculants by microwave- and ultrasound-assisted methods.
Klein, Jalma Maria; de Lima, Vanessa Silva; da Feira, José Manoel Couto; Camassola, Marli; Brandalise, Rosmary Nichele; Forte, Maria Madalena de Camargo
2018-02-01
In this work, copolymers based on cashew gum (CG) grafted with polyacrylamide (PAM) were synthesized by microwave- and ultrasound-assisted methods, using potassium persulfate as an initiator in aqueous medium. The graft copolymers were characterized by Fourier-transform infrared spectroscopy, nuclear magnetic resonance spectroscopy, and thermogravimetric analysis. The efficiency of the graft copolymers (CG-g-PAM) in flocculation of a kaolin suspension was studied. Results indicated that the graft copolymers synthesized by ultrasound energy had better flocculation properties than the ones synthesized by the microwave-assisted method. The biodegradability of the graft copolymers was tested by inoculation with the basidiomycete Trametes villosa in liquid medium. The higher formation of biomass than that observed with the commercial flocculant Flonex-9045 indicated that the graft copolymer was accessible to enzymatic attack. Copyright © 2017 Elsevier B.V. All rights reserved.
Guideline for diagnosis and treatment of subacromial pain syndrome
Diercks, Ron; Bron, Carel; Dorrestijn, Oscar; Meskers, Carel; Naber, René; de Ruiter, Tjerk; Willems, Jaap; Winters, Jan; van der Woude, Henk Jan
2014-01-01
Treatment of “subacromial impingement syndrome” of the shoulder has changed drastically in the past decade. The anatomical explanation as “impingement” of the rotator cuff is not sufficient to cover the pathology. “Subacromial pain syndrome”, SAPS, describes the condition better. A working group formed from a number of Dutch specialist societies, joined by the Dutch Orthopedic Association, has produced a guideline based on the available scientific evidence. This resulted in a new outlook for the treatment of subacromial pain syndrome. The important conclusions and advice from this work are as follows: (1) The diagnosis SAPS can only be made using a combination of clinical tests. (2) SAPS should preferably be treated non-operatively. (3) Acute pain should be treated with analgetics if necessary. (4) Subacromial injection with corticosteroids is indicated for persistent or recurrent symptoms. (5) Diagnostic imaging is useful after 6 weeks of symptoms. Ultrasound examination is the recommended imaging, to exclude a rotator cuff rupture. (6) Occupational interventions are useful when complaints persist for longer than 6 weeks. (7) Exercise therapy should be specific and should be of low intensity and high frequency, combining eccentric training, attention to relaxation and posture, and treatment of myofascial trigger points (including stretching of the muscles) may be considered. (8) Strict immobilization and mobilization techniques are not recommended. (9) Tendinosis calcarea can be treated by shockwave (ESWT) or needling under ultrasound guidance (barbotage). (10) Rehabilitation in a specialized unit can be considered in chronic, treatment resistant SAPS, with pain perpetuating behavior. (11) There is no convincing evidence that surgical treatment for SAPS is more effective than conservature management. (12) There is no indication for the surgical treatment of asymptomatic rotator cuff tears. PMID:24847788
Studies on the use of power ultrasound in leather dyeing.
Sivakumar, Venkatasubramanian; Rao, Paruchuri Gangadhar
2003-03-01
Uses of power ultrasound for acceleration/performing the chemical as well as physical processes are gaining importance. In conventional leather processing, the diffusion of chemicals through the pores of the skin/hide is achieved by the mechanical agitation caused by the paddle or drumming action. In this work, the use of power ultrasound in the dyeing of leather has been studied with the aim to improve the exhaustion of dye for a given processing time, to reduce the dyeing time and to improve the quality of dyed leather. The effect of power ultrasound in the dyeing of full chrome cow crust leather in a stationary condition is compared with dyeing in the absence of ultrasound as a control experiment both in a stationary as well as conventional drumming condition. An ultrasonic cleaner (150 W and 33 kHz) was used for the experiments. Actual power dissipated into the system was calculated from the calorimetric measurement. Experiments were carried out with variation in type of dye, amount of dye offer, temperature and time. The results show that there is a significant improvement in the percentage exhaustion of dye due to the presence of ultrasound, when compared to dyeing in absence of ultrasound. Experiments on equilibrium dye uptake carried out with or without ultrasound suggest that ultrasound help to improve the kinetics of leather dyeing. The results indicate that leathers dyed in presence of ultrasound have higher colour values, better dye penetration and fastness properties compared to control leathers. The physical testing results show that strength properties of the dyed leathers are not affected due to the application of ultrasound under the given process conditions. Apparent diffusion coefficient during the initial stage of dyeing process, both in presence and in absence of ultrasound was calculated. The values show that ultrasound helps in improving the apparent diffusion coefficient more for the difficult dyeing conditions such as in the case of metal-complex dyes having bigger aggregate size compared to less difficult dyeing conditions.
A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.
Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik
2017-12-01
Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.
Hotfiel, Thilo; Heiss, Rafael; Swoboda, Bernd; Kellermann, Marion; Gelse, Kolja; Grim, Casper; Strobel, Deike; Wildner, Dane
2018-07-01
To emphasize the diagnostic value of contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries with different degrees of severity by comparing findings to established imaging modalities such as conventional ultrasound and magnetic resonance imaging (MRI). Case series. Institutional study. Conventional ultrasound and CEUS were performed in the Department of Internal Medicine. Magnetic resonance imaging was carried out in the Department of Radiology within the Magnetom Avanto 1.5T and Magnetom Skyra fit 3T (Siemens Healthineers, Erlangen, Germany) and in the Institution of Imaging Diagnostics and Therapy (Magnetom Avanto 1.5T; Siemens, Erlangen, Germany). Fifteen patients who underwent an acute muscle injury were recruited. The appearance and detectable size of muscle injuries were compared between each imaging modality. The injuries were assessed by 3 independent observers and blinded between imaging modalities. All 15 injuries were identified on MRI and CEUS, whereas 10 injuries showed abnormalities in conventional ultrasound. The determination and measurement revealed significant differences between conventional ultrasound and CEUS depending on injury severity. Contrast-enhanced ultrasound revealed an impairment of microcirculation in grade I lesions (corresponding to intramuscular edema observed in MRI), which was not detectable using conventional ultrasound. Our results indicate that performing CEUS seems to be a sensitive additional diagnostic modality in the early assessment of muscle injuries. Our results highlight the advantages of CEUS in the imaging of low-grade lesions when compared with conventional ultrasound, as this was the more accurate modality for identifying intramuscular edema.
Aptamer-conjugated nanobubbles for targeted ultrasound molecular imaging.
Wang, Chung-Hsin; Huang, Yu-Fen; Yeh, Chih-Kuang
2011-06-07
Targeted ultrasound contrast agents can be prepared by some specific bioconjugation techniques. The biotin-avidin complex is an extremely useful noncovalent binding system, but the system might induce immunogenic side effects in human bodies. Previous proposed covalently conjugated systems suffered from low conjugation efficiency and complex procedures. In this study, we propose a covalently conjugated nanobubble coupling with nucleic acid ligands, aptamers, for providing a higher specific affinity for ultrasound targeting studies. The sgc8c aptamer was linked with nanobubbles through thiol-maleimide coupling chemistry for specific targeting to CCRF-CEM cells. Further improvements to reduce the required time and avoid the degradation of nanobubbles during conjugation procedures were also made. Several investigations were used to discuss the performance and consistency of the prepared nanobubbles, such as size distribution, conjugation efficiency analysis, and flow cytometry assay. Further, we applied our conjugated nanobubbles to ex vivo ultrasound targeted imaging and compared the resulting images with optical images. The results indicated the availability of aptamer-conjugated nanobubbles in targeted ultrasound imaging and the practicability of using a highly sensitive ultrasound system in noninvasive biological research.
Controlled morphology and size of curcumin using ultrasound in supercritical CO2 antisolvent.
Jia, Jingfu; Wang, Wucong; Gao, Yahui; Zhao, Yaping
2015-11-01
Controllable morphology and size of crystal materials prepared by using a supercritical antisolvent (SAS) technique is still challenge. In this study, ultrasound was introduced into the SAS process to produce the particles of curcumin, a model compound. The effects of ultrasound power on the particle morphology and size were investigated in the range of 0 and 240 W at three different pressures. The observation of jet flow indicated ultrasound could accelerate the mixing speed between the liquid solution and the CO2, and thus reduced the gaseous region and the local saturation gradient. Mixed polymorphic and uniform particles of the curcumin were produced at a low and high mixing speed, respectively, confirmed by scanning electron microscopy. The needle- or rod-like particle, irregular lumpy particle and nano spherical particle were generated with the increase of the ultrasound power, attributed to the changes of the degree of supersaturation. Therefore, the ultrasound can be potentially applied to adjust the morphology and size of the crystal materials in supercritical CO2 antisolvent. Copyright © 2015 Elsevier B.V. All rights reserved.
Gourevich, Dana; Volovick, Alexander; Dogadkin, Osnat; Wang, Lijun; Mulvana, Helen; Medan, Yoav; Melzer, Andreas; Cochran, Sandy
2015-07-01
Ultrasound-mediated targeted drug delivery is a therapeutic modality under development with the potential to treat cancer. Its ability to produce local hyperthermia and cell poration through cavitation non-invasively makes it a candidate to trigger drug delivery. Hyperthermia offers greater potential for control, particularly with magnetic resonance imaging temperature measurement. However, cavitation may offer reduced treatment times, with real-time measurement of ultrasonic spectra indicating drug dose and treatment success. Here, a clinical magnetic resonance imaging-guided focused ultrasound surgery system was used to study ultrasound-mediated targeted drug delivery in vitro. Drug uptake into breast cancer cells in the vicinity of ultrasound contrast agent was correlated with occurrence and quantity of stable and inertial cavitation, classified according to subharmonic spectra. During stable cavitation, intracellular drug uptake increased by a factor up to 3.2 compared with the control. Reported here are the value of cavitation monitoring with a clinical system and its subsequent employment for dose optimization. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Thakur, Sachin S; Ward, Micheal S; Popat, Amirali; Flemming, Nicole B; Parat, Marie-Odile; Barnett, Nigel L; Parekh, Harendra S
2017-01-01
Herein we showcase the potential of ultrasound-responsive nanobubbles in enhancing macromolecular permeation through layers of the retina, ultimately leading to significant and direct intracellular delivery; this being effectively demonstrated across three relevant and distinct retinal cell lines. Stably engineered nanobubbles of a highly homogenous and echogenic nature were fully characterised using dynamic light scattering, B-scan ultrasound and transmission electron microscopy (TEM). The nanobubbles appeared as spherical liposome-like structures under TEM, accompanied by an opaque luminal core and darkened corona around their periphery, with both features indicative of efficient gas entrapment and adsorption, respectively. A nanobubble +/- ultrasound sweeping study was conducted next, which determined the maximum tolerated dose for each cell line. Detection of underlying cellular stress was verified using the biomarker heat shock protein 70, measured before and after treatment with optimised ultrasound. Next, with safety to nanobubbles and optimised ultrasound demonstrated, each human or mouse-derived cell population was incubated with biotinylated rabbit-IgG in the presence and absence of ultrasound +/- nanobubbles. Intracellular delivery of antibody in each cell type was then quantified using Cy3-streptavidin. Nanobubbles and optimised ultrasound were found to be negligibly toxic across all cell lines tested. Macromolecular internalisation was achieved to significant, yet varying degrees in all three cell lines. The results of this study pave the way towards better understanding mechanisms underlying cellular responsiveness to ultrasound-triggered drug delivery in future ex vivo and in vivo models of the posterior eye.
Thakur, Sachin S.; Ward, Micheal S.; Popat, Amirali; Flemming, Nicole B.; Parat, Marie-Odile; Barnett, Nigel L.
2017-01-01
Herein we showcase the potential of ultrasound-responsive nanobubbles in enhancing macromolecular permeation through layers of the retina, ultimately leading to significant and direct intracellular delivery; this being effectively demonstrated across three relevant and distinct retinal cell lines. Stably engineered nanobubbles of a highly homogenous and echogenic nature were fully characterised using dynamic light scattering, B-scan ultrasound and transmission electron microscopy (TEM). The nanobubbles appeared as spherical liposome-like structures under TEM, accompanied by an opaque luminal core and darkened corona around their periphery, with both features indicative of efficient gas entrapment and adsorption, respectively. A nanobubble +/- ultrasound sweeping study was conducted next, which determined the maximum tolerated dose for each cell line. Detection of underlying cellular stress was verified using the biomarker heat shock protein 70, measured before and after treatment with optimised ultrasound. Next, with safety to nanobubbles and optimised ultrasound demonstrated, each human or mouse-derived cell population was incubated with biotinylated rabbit-IgG in the presence and absence of ultrasound +/- nanobubbles. Intracellular delivery of antibody in each cell type was then quantified using Cy3-streptavidin. Nanobubbles and optimised ultrasound were found to be negligibly toxic across all cell lines tested. Macromolecular internalisation was achieved to significant, yet varying degrees in all three cell lines. The results of this study pave the way towards better understanding mechanisms underlying cellular responsiveness to ultrasound-triggered drug delivery in future ex vivo and in vivo models of the posterior eye. PMID:28542473
Singh, M Suheshkumar; Yalavarthy, Phaneendra K; Vasu, R M; Rajan, K
2010-07-01
To assess the effect of ultrasound modulation of near infrared (NIR) light on the quantification of scattering coefficient in tissue-mimicking biological phantoms. A unique method to estimate the phase of the modulated NIR light making use of only time averaged intensity measurements using a charge coupled device camera is used in this investigation. These experimental measurements from tissue-mimicking biological phantoms are used to estimate the differential pathlength, in turn leading to estimation of optical scattering coefficient. A Monte-Carlo model based numerical estimation of phase in lieu of ultrasound modulation is performed to verify the experimental results. The results indicate that the ultrasound modulation of NIR light enhances the effective scattering coefficient. The observed effective scattering coefficient enhancement in tissue-mimicking viscoelastic phantoms increases with increasing ultrasound drive voltage. The same trend is noticed as the ultrasound modulation frequency approaches the natural vibration frequency of the phantom material. The contrast enhancement is less for the stiffer (larger storage modulus) tissue, mimicking tumor necrotic core, compared to the normal tissue. The ultrasound modulation of the insonified region leads to an increase in the effective number of scattering events experienced by NIR light, increasing the measured phase, causing the enhancement in the effective scattering coefficient. The ultrasound modulation of NIR light could provide better estimation of scattering coefficient. The observed local enhancement of the effective scattering coefficient, in the ultrasound focal region, is validated using both experimental measurements and Monte-Carlo simulations.
Sostaric, Joe Z; Miyoshi, Norio; Cheng, Jason Y; Riesz, Peter
2008-10-09
Suspensions of human leukemia (HL-60) cells readily undergo cytolysis when exposed to ultrasound above the acoustic cavitation threshold. However, n-alkyl glucopyranosides (hexyl, heptyl, and octyl) completely inhibit ultrasound-induced (1057 kHz) cytolysis (Sostaric, et al. Free Radical Biol. Med. 2005, 39, 1539-1548). The efficacy of protection from ultrasound-induced cytolysis was determined by the n-alkyl chain length of the glucopyranosides, indicating that protection efficacy depended on adsorption of n-alkyl glucopyranosides to the gas/solution interface of cavitation bubbles and/or the lipid membrane of cells. The current study tests the hypothesis that "sonoprotection" (i.e., protection of cells from ultrasound-induced cytolysis) in vitro depends on the adsorption of glucopyranosides at the gas/solution interface of cavitation bubbles. To test this hypothesis, the effect of ultrasound frequency (from 42 kHz to 1 MHz) on the ability of a homologous series of n-alkyl glucopyranosides to protect cells from ultrasound-induced cytolysis was investigated. It is expected that ultrasound frequency will affect sonoprotection ability since the nature of the cavitation bubble field will change. This will affect the relative importance of the possible mechanisms for ultrasound-induced cytolysis. Additionally, ultrasound frequency will affect the lifetime and rate of change of the surface area of cavitation bubbles, hence the dynamically controlled adsorption of glucopyranosides to their surface. The data support the hypothesis that sonoprotection efficiency depends on the ability of glucopyranosides to adsorb at the gas/solution interface of cavitation bubbles.
Mirelis, Jesús G; García-Pavía, Pablo; Cavero, Miguel A; González-López, Esther; Echavarria-Pinto, Mauro; Pastrana, Miguel; Segovia, Javier; Oteo, Juan F; Alonso-Pulpón, Luis; Escaned, Javier
2015-07-01
Cardiac allograft vasculopathy affects both epicardial and microcirculatory coronary compartments. Magnetic resonance perfusion imaging has been proposed as a useful tool to assess microcirculation mostly outside the heart transplantation setting. Instantaneous hyperemic diastolic flow velocity-pressure slope, an intracoronary physiology index, has demonstrated a better correlation with microcirculatory remodelling in cardiac allograft vasculopathy than other indices such as coronary flow velocity reserve. To investigate the potential of magnetic resonance perfusion imaging to detect the presence of microcirculatory remodeling in cardiac allograft vasculopathy, we compared magnetic resonance perfusion data with invasive intracoronary physiological indices to study microcirculation in a population of heart transplantation recipients with macrovascular nonobstructive disease demonstrated with intravascular ultrasound. We studied 8 heart transplantation recipients (mean age, 61 [12] years, 100% male) with epicardial allograft vasculopathy defined by intravascular ultrasound, nonsignificant coronary stenoses and negative visually-assessed wall-motion/perfusion dobutamine stress magnetic resonance. Quantitative stress and rest magnetic resonance perfusion data to build myocardial perfusion reserve index, noninvasively, and 4 invasive intracoronary physiological indices were determined. Postprocessed data showed a mean (standard deviation) myocardial perfusion reserve index of 1.22 (0.27), while fractional flow reserve, coronary flow velocity reserve, hyperemic microvascular resistance and instantaneous hyperemic diastolic flow velocity-pressure slope were 0.98 (0.02), cm/s/mmHg, 2.34 (0.55) cm/s/mmHg, 2.00 (0.69) cm/s/mmHg and 0.91 (0.65) cm/s/mmHg, respectively. The myocardial perfusion reserve index correlated strongly only with the instantaneous hyperemic diastolic flow velocity-pressure slope (r=0.75; P=.033). Myocardial perfusion reserve index derived from a comprehensive dobutamine stress magnetic resonance appears to be a reliable technique for noninvasive detection of microcirculatory coronary disease associated with cardiac allograft vasculopathy. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Huang, Shih-Wei; Liu, Sen-Yung; Tang, Hao-Wei; Wei, Ta-Sen; Wang, Wei-Te; Yang, Chao-Pin
2012-09-01
The aims of this study were: (i) to determine whether the severity of post-hemiplegic shoulder subluxation in stroke patients correlates with soft-tissue injury; and (ii) to determine the shoulder subluxation measurement cut-off points that are indications for further ultrasound examination for soft-tissue injuries in these patients. Cross-sectional study. A total of 39 stroke patients with shoulder subluxation. Shoulder subluxation was evaluated by physical examination, radiography and ultrasound. Soft-tissue injuries were assessed by ultrasound. Subluxation parameters were entered into stepwise logistic regression analyses to predict biceps and supraspinatus tendonitis. With the assumption that shoulder subluxation can be a predisposing factor for tendonitis, receiver operating characteristic curves for shoulder subluxation parameters of the affected side were used to determine cut-off points for optimal sensitivity and specificity of biceps and supraspinatus tendonitis. Shoulder subluxation lateral distance, measured by physical examination, is a predictor for supraspinatus tendonitis (odds ratio = 34.9, p = 0.036). Further ultrasound investigation for soft-tissue injury is indicated when subluxation lateral distance, measured by physical examination is ≥ 2.25 cm or, measured by radiographic examination, ≥ 3.18 cm for lateral distance, ≥ 3.08 cm for vertical distance, or ≥ 2.65 cm for horizontal distance. When post-hemiplegic shoulder subluxation measurements exceed the above-mentioned cut-off points in physical or radiographic examinations, further ultrasound evaluation for soft-tissue injury is recommended.
THREE-DIMENSIONAL MODELING OF THE DYNAMICS OF THERAPEUTIC ULTRASOUND CONTRAST AGENTS
Hsiao, Chao-Tsung; Lu, Xiaozhen; Chahine, Georges
2010-01-01
A 3-D thick-shell contrast agent dynamics model was developed by coupling a finite volume Navier-Stokes solver and a potential boundary element method flow solver to simulate the dynamics of thick-shelled contrast agents subjected to pressure waves. The 3-D model was validated using a spherical thick-shell model validated by experimental observations. We then used this model to study shell break-up during nonspherical deformations resulting from multiple contrast agent interaction or the presence of a nearby solid wall. Our simulations indicate that the thick viscous shell resists the contrast agent from forming a re-entrant jet, as normally observed for an air bubble oscillating near a solid wall. Instead, the shell thickness varies significantly from location to location during the dynamics, and this could lead to shell break-up caused by local shell thinning and stretching. PMID:20950929
Lin, Wen; Xie, Xiangyang; Deng, Jianping; Liu, Hui; Chen, Ying; Fu, Xudong; Liu, Hong; Yang, Yang
2016-01-01
A new drug-targeting system for CD13(+) tumors has been developed, based on ultrasound-sensitive nanobubbles (NBs) and cell-permeable peptides (CPPs). Here, the CPP-doxorubicin conjugate (CPP-DOX) was entrapped in the asparagine-glycine-arginine (NGR) peptide modified NB (CPP-DOX/NGR-NB) and the penetration of CPP-DOX was temporally masked; local ultrasound stimulation could trigger the CPP-DOX release from NB and activate its penetration. The CPP-DOX/NGR-NBs had particle sizes of about 200 nm and drug entrapment efficiency larger than 90%. In vitro release results showed that over 85% of the encapsulated DOX or CPP-DOX would release from NBs in the presence of ultrasound, while less than 1.5% of that (30 min) without ultrasound. Cell experiments showed the higher cellular CPP-DOX uptake of CPP-DOX/NGR-NB among the various NB formulations in Human fibrosarcoma cells (HT-1080, CD13(+)). The CPP-DOX/NGR-NB with ultrasound treatment exhibited an increased cytotoxic activity than the one without ultrasound. In nude mice xenograft of HT-1080 cells, CPP-DOX/NGR-NB with ultrasound showed a higher tumor inhibition effect (3.1% of T/C%, day 24), longer median survival time (50 days) and excellent body safety compared with the normal DOX injection group. These results indicate that the constructed vesicle would be a promising drug delivery system for specific cancer treatment.
Lee, Jae-Ho; Park, Jeung-Jin; Choi, Gi-Choong; Byun, Im-Gyu; Park, Tae-Joo; Lee, Tae-Ho
2013-01-01
Spent sulfidic caustic (SSC) produced from petroleum industry can be reused to denitrify nitrate-nitrogen via a biological nitrogen removal process as an electron donor for sulfur-based autotrophic denitrification, because it has a large amount of dissolved sulfur. However, SSC has to be refined because it also contains some aromatic hydrocarbons, typically benzene, toluene, ethylbenzene, xylene (BTEX) and phenol that are recalcitrant organic compounds. In this study, laboratory-scale ultrasound irradiation and air stripping treatment were applied in order to remove these aromatic hydrocarbons. In the ultrasound system, both BTEX and phenol were exponentially removed by ultrasound irradiation during 60 min of reaction time to give the greatest removal efficiency of about 80%. Whereas, about 95% removal efficiency of BTEX was achieved, but not any significant phenol removal, within 30 min in the air stripping system, indicating that air stripping was a more efficient method than ultrasound irradiation. However, since air stripping did not remove any significant phenol, an additional process for degrading phenol was required. Accordingly, we applied a combined ultrasound and air stripping process. In these experiments, the removal efficiencies of BTEX and phenol were improved compared to the application of ultrasound and air stripping alone. Thus, the combined ultrasound and air stripping treatment is appropriate for refining SSC.
Tang, Wei; Liu, Quanhong; Wang, Xiaobing; Wang, Pan; Zhang, Jing; Cao, Bing
2009-12-01
Sonodynamic therapy employs a combination of ultrasound and a sonosensitizer to enhance the cytotoxic effect of ultrasound and promote apoptosis. However, the mechanism underlying the synergistic effect of ultrasound and hematoporphyrin is still unclear. In this study, we investigated mechanism of the induction of apoptosis by sonodynamic therapy in Sarcoma 180 cells. The cell suspension was treated by 1.75-MHz focused continuous ultrasound at an acoustic power (I(SATA)) of 1.4+/-0.07 W/cm(2) for 3 min in the absence or presence of 20 microg/ml hematoporphyrin. The proportion of apoptotic cells was determined by flow cytometry. We then analyzed the reactive oxygen species generation and localization by confocal microscopy. Western blotting and reverse transcriptase-polymerase chain reaction were used to analyze the expression of caspase-8, caspase-9, poly(ADP)-ribose polymerase, and nuclear factor-kappaB. The findings of our study indicate that ultrasound treatment induced the activation of nuclear factor-kappaB as an early stress response. When cells were pretreated with hematoporphyrin, the initial response to the therapy was the formation of (1)O(2) in the mitochondria. Our results primarily demonstrate that the mechanisms of induction of apoptosis by ultrasound and hematoporphyrin-sonodynamic therapies are very different. Our findings can provide a basis for explaining the synergistic effect of ultrasound and hematoporphyrin.
Survey of ultrasound practice amongst podiatrists in the UK.
Siddle, Heidi J; Patience, Aimie; Coughtrey, James; Mooney, Jean; Fox, Martin; Cherry, Lindsey
2018-01-01
Ultrasound in podiatry practice encompasses musculoskeletal ultrasound imaging, vascular hand-held Doppler ultrasound and therapeutic ultrasound. Sonography practice is not regulated by the Health and Care Professions Council (HCPC), with no requirement to hold a formal qualification. The College of Podiatry does not currently define ultrasound training and competencies.This study aimed to determine the current use of ultrasound, training received and mentorship received and/or provided by podiatrists using ultrasound. A quantitative study utilising a cross-sectional, on-line, single-event survey was undertaken within the UK. Completed surveys were received from 284 podiatrists; 173 (70%) use ultrasound as part of their general practice, 139 (49%) for musculoskeletal problems, 131 (46%) for vascular assessment and 39 (14%) to support their surgical practice. Almost a quarter ( n = 62) worked for more than one organisation; 202 (71%) were employed by the NHS and/or private sector ( n = 118, 41%).Nearly all (93%) respondents report using a hand-held vascular Doppler in their daily practice; 216 (82%) to support decisions regarding treatment options, 102 (39%) to provide diagnostic reports for other health professionals, and 34 (13%) to guide nerve blocks.Ultrasound imaging was used by 104 (37%) respondents primarily to aid clinical decision making ( n = 81) and guide interventions (steroid injections n = 67; nerve blocks n = 39). Ninety-three percent stated they use ultrasound imaging to treat their own patients, while others scan at the request of other podiatrists ( n = 28) or health professionals ( n = 18). Few use ultrasound imaging for research ( n = 7) or education ( n = 2).Only 32 (11%) respondents ( n = 20 private sector) use therapeutic ultrasound to treat patients presenting with musculoskeletal complaints, namely tendon pathologies.Few respondents (18%) had completed formal post-graduate CASE (Consortium for the Accreditation of Sonographic Education) accredited ultrasound courses.Forty (14%) respondents receive ultrasound mentorship; the majority from fellow podiatrists ( n = 17) or medical colleagues ( n = 15). Over half ( n = 127) who do not have ultrasound mentorship indicated they would like a mentor predominantly for ultrasound imaging. Fifty-five (19%) report they currently provide ultrasound mentorship for others. Understanding the scope of ultrasound practice, the training undertaken and the requirements for mentorship will underpin the development of competencies and recommendations defined by the College of Podiatry to support professional development and ensure safe practice.
NASA Astrophysics Data System (ADS)
Chu, Po-Chun; Chai, Wen-Yen; Tsai, Chih-Hung; Kang, Shih-Tsung; Yeh, Chih-Kuang; Liu, Hao-Li
2016-09-01
Focused ultrasound (FUS) with microbubbles can temporally open the blood-brain barrier (BBB), and the cavitation activities of microbubbles play a key role in the BBB-opening process. Previous attempts used contrast-enhanced magnetic resonance imaging (CE-MRI) to correlate the mechanical index (MI) with the scale of BBB-opening, but MI only partially gauged acoustic activities, and CE-MRI did not fully explore correlations of pharmacodynamic/pharmacokinetic behaviors. Recently, the cavitation index (CI) has been derived to serve as an indicator of microbubble-ultrasound stable cavitation, and may also serve as a valid indicator to gauge the level of FUS-induced BBB opening. This study investigates the feasibility of gauging FUS-induced BBB opened level via the two indexes, MI and CI, through dynamic contrast-enhanced (DCE)-MRI analysis as well as passive cavitation detection (PCD) analysis. Pharmacodynamic/pharmacokinetic parameters derived from DCE-MRI were characterized to identify the scale of FUS-induced BBB opening. Our results demonstrated that DCE-MRI can successfully access pharmacodynamic/pharmacokinetic BBB-opened behavior, and was highly correlated both with MI and CI, implying the feasibility in using these two indices to gauge the scale of FUS-induced BBB opening. The proposed finding may facilitate the design toward using focused ultrasound as a safe and reliable noninvasive CNS drug delivery.
Chu, Po-Chun; Chai, Wen-Yen; Tsai, Chih-Hung; Kang, Shih-Tsung; Yeh, Chih-Kuang; Liu, Hao-Li
2016-09-15
Focused ultrasound (FUS) with microbubbles can temporally open the blood-brain barrier (BBB), and the cavitation activities of microbubbles play a key role in the BBB-opening process. Previous attempts used contrast-enhanced magnetic resonance imaging (CE-MRI) to correlate the mechanical index (MI) with the scale of BBB-opening, but MI only partially gauged acoustic activities, and CE-MRI did not fully explore correlations of pharmacodynamic/pharmacokinetic behaviors. Recently, the cavitation index (CI) has been derived to serve as an indicator of microbubble-ultrasound stable cavitation, and may also serve as a valid indicator to gauge the level of FUS-induced BBB opening. This study investigates the feasibility of gauging FUS-induced BBB opened level via the two indexes, MI and CI, through dynamic contrast-enhanced (DCE)-MRI analysis as well as passive cavitation detection (PCD) analysis. Pharmacodynamic/pharmacokinetic parameters derived from DCE-MRI were characterized to identify the scale of FUS-induced BBB opening. Our results demonstrated that DCE-MRI can successfully access pharmacodynamic/pharmacokinetic BBB-opened behavior, and was highly correlated both with MI and CI, implying the feasibility in using these two indices to gauge the scale of FUS-induced BBB opening. The proposed finding may facilitate the design toward using focused ultrasound as a safe and reliable noninvasive CNS drug delivery.
Optical fiber extrinsic Fabry-Perot interferometer sensors for ultrasound detection
NASA Astrophysics Data System (ADS)
Sun, Qingguo; Chen, Na; Ding, Yuetong; Chen, Zhenyi; Wang, Tingyun
2009-11-01
In this paper, a new method is proposed to fabricate an optical fiber extrinsic Fabry-Perot interferometer (EFPI) as an ultrasonic sensor. An acoustic emission detecting system is constructed based on multiple EFPI sensors and demodulation circuit. Ultrasound detection experiments were done from both traditional piezoelectric transducer (PZT) and high voltage discharge. In the experiments, strong ultrasound signals were detected in both cases. The signal attenuation related to the distance and the angle between the acoustic emission source and the FP sensor are obtained. The results indicate that the receiving angle of the FP sensor is nearly 90° and the maximum detection distance in the air is more than 200cm. Furthermore, four sensors are used to locate the position of the ultrasound source produced by high voltage discharge.
Mohler, Emile R.; Gornik, Heather L.; Gerhard-Herman, Marie; Misra, Sanjay; Olin, Jeffrey W.; Zierler, R. Eugene; Wolk, Michael J.; Mohler, Emile R.; Dixon, Bradley S.; Driver, Vickie R.; Fail, Peter S.; Fazel, Reza; Findeiss, Laura; Fuchs, Richard; Gillespie, John; Hughes, Joseph P.; Jaigobin, Cheryl; Leers, Steven A.; Moore, Colleen; Pellerito, John S.; Robbin, Michelle L.; Shugart, Rita E.; Weaver, Fred A.; White, Christopher J.; Yevzlin, Alexander S.; Wolk, Michael J.; Bailey, Steven R.; Douglas, Pamela S.; Hendel, Robert C.; Kramer, Christopher M.; Min, James K.; Patel, Manesh R.; Shaw, Leslee; Stainback, Raymond F.; Allen, Joseph M.
2015-01-01
The American College of Cardiology Foundation (ACCF), in partnership with key specialty and subspecialty societies, conducted a review of common clinical scenarios where noninvasive vascular testing (ultrasound and physiological testing) is frequently considered. The indications (clinical scenarios) were derived from common applications or anticipated uses, as well as from current clinical practice guidelines and results of studies examining the implementation of the original appropriate use criteria (AUC). The 159 indications in this document were developed by a diverse writing group and scored by a separate independent technical panel on a scale of 1 to 9, to designate appropriate use (median 7 to 9), uncertain use (median 4 to 6), and inappropriate use (median 1 to 3). A total of 255 indications (with the inclusion of surveillance timeframes) were rated. One hundred and seventeen indications were rated as appropriate, 84 were rated as uncertain, and 54 were rated as inappropriate. The AUC for peripheral vascular disease have the potential to impact physician decision making, healthcare delivery, and reimbursement policy. Furthermore, recognition of uncertain clinical scenarios facilitates identification of areas that would benefit from future research. PMID:22694840
Global health indicators and maternal health futures: The case of Intrauterine Growth Restriction.
Erikson, Susan L
2015-01-01
Public health indicators generally operate in the world as credible, apolitical and authoritative. But indicators are less stable than they appear. Clinical critiques of Intrauterine Growth Restriction (IUGR) criteria have been forthcoming for decades. This article, though, takes up the measuring and calculation gradients of IUGR in the ultrasound machine itself, including the software algorithms that identify IUGR. One hospital where research was conducted incorrectly predicted pathological birth outcomes 14 of 14 times. We are at a historical moment when the global use of prenatal diagnostic ultrasound for the express purpose of assessing IUGR is set to escalate. Medical imaging device corporations like Siemens, Toshiba, General Electric and Phillips are quite literally banking on it, and new forms of ultrasound technology and diagnostic software are increasingly available on smartphones, tablets and laptops. Clinical guidelines for IUGR--assumed to be authoritative and evidence-based--are evolving right along with the installation throughout the world of the technology capable of diagnosing it. Maternal malnutrition remains the single strongest predictive factor for IUGR, regardless of the technological investments currently amassing to identify the indicator, which is cause for a reassessment of priority spending and investment.
Polymer film-nanoparticle composites as new multimodality, non-migrating breast biopsy markers.
Kaplan, Jonah A; Grinstaff, Mark W; Bloch, B Nicolas
2016-03-01
To develop a breast biopsy marker that resists fast and slow migration and has permanent visibility under commonly used imaging modalities. A polymer-nanoparticle composite film was prepared by embedding superparamagnetic iron oxide nanoparticles and a superelastic Nitinol wire within a flexible polyethylene matrix. MRI, mammography, and ultrasound were used to visualize the marker in agar, ex vivo chicken breast, bovine liver, brisket, and biopsy training phantoms. Fast migration caused by the "accordion effect" was quantified after simulated stereotactic, vacuum-assisted core biopsy/marker placement, and centrifugation was used to simulate accelerated long-term (i.e., slow) migration in ex vivo bovine tissue phantoms. Clear marker visualization under MRI, mammography, and ultrasound was observed. After deployment, the marker partially unfolds to give a geometrically constrained structure preventing fast and slow migration. The marker can be deployed through an 11G introducer without fast migration occurring, and shows substantially less slow migration than conventional markers. The polymer-nanoparticle composite biopsy marker is clearly visible on all clinical imaging modalities and does not show substantial migration, which ensures multimodal assessment of the correct spatial information of the biopsy site, allowing for more accurate diagnosis and treatment planning and improved breast cancer patient care. Polymer-nanoparticle composite biopsy markers are visualized using ultrasound, MRI, and mammography. Embedded iron oxide nanoparticles provide tuneable contrast for MRI visualization. Permanent ultrasound visibility is achieved with a non-biodegradable polymer having a distinct ultrasound signal. Flexible polymer-based biopsy markers undergo shape change upon deployment to minimize migration. Non-migrating multimodal markers will help improve accuracy of pre/post-treatment planning studies.
Sikes, Anita L; Mawson, Raymond; Stark, Janet; Warner, Robyn
2014-11-01
The delivery of a consistent quality product to the consumer is vitally important for the food industry. The aim of this study was to investigate the potential for using high frequency ultrasound applied to pre- and post-rigor beef muscle on the metabolism and subsequent quality. High frequency ultrasound (600kHz at 48kPa and 65kPa acoustic pressure) applied to post-rigor beef striploin steaks resulted in no significant effect on the texture (peak force value) of cooked steaks as measured by a Tenderometer. There was no added benefit of ultrasound treatment above that of the normal ageing process after ageing of the steaks for 7days at 4°C. Ultrasound treatment of post-rigor beef steaks resulted in a darkening of fresh steaks but after ageing for 7days at 4°C, the ultrasound-treated steaks were similar in colour to that of the aged, untreated steaks. High frequency ultrasound (2MHz at 48kPa acoustic pressure) applied to pre-rigor beef neck muscle had no effect on the pH, but the calculated exhaustion factor suggested that there was some effect on metabolism and actin-myosin interaction. However, the resultant texture of cooked, ultrasound-treated muscle was lower in tenderness compared to the control sample. After ageing for 3weeks at 0°C, the ultrasound-treated samples had the same peak force value as the control. High frequency ultrasound had no significant effect on the colour parameters of pre-rigor beef neck muscle. This proof-of-concept study showed no effect of ultrasound on quality but did indicate that the application of high frequency ultrasound to pre-rigor beef muscle shows potential for modifying ATP turnover and further investigation is warranted. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ter Haar, Gail; Kennedy, James; Leslie, Tom; Wu, Feng
2005-09-01
Currently, many clinical devices use the change in gray scale seen on a real-time ultrasound image for the assessment of the success of HIFU treatment. It has been shown previously that, for a single HIFU lesion, the presence of gray-scale change was indicative of successful ablation in 100% of cases for 1.6-MHz beams, and in 90% of cases for 0.8-MHz exposures. The absence of gray-scale change was a reliable indicator of lack of ablative damage only for 0.8-MHz exposures (80%) in 80% of exposures using 1.6-MHz beams there was a lesion even in the absence of gray-scale change. This study has been extended to more realistic clinical treatment protocols. The image appearance has been studied for the different volume ablation techniques that are used in the treatment of liver and kidney cancer. The results will be presented.
Videodensitometric Methods for Cardiac Output Measurements
NASA Astrophysics Data System (ADS)
Mischi, Massimo; Kalker, Ton; Korsten, Erik
2003-12-01
Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA) are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.
Ultrasonically-induced electrical potentials in demineralized bovine cortical bone
NASA Astrophysics Data System (ADS)
Mori, Shunki; Makino, Taiki; Koyama, Daisuke; Takayanagi, Shinji; Yanagitani, Takahiko; Matsukawa, Mami
2018-04-01
While the low-intensity pulsed ultrasound technique has proved useful for healing of bone fractures, the ultrasound healing mechanism is not yet understood. To understand the initial physical effects of the ultrasound irradiation process on bone, we have studied the anisotropic piezoelectric properties of bone in the MHz range. Bone is known to be composed of collagen and hydroxyapatite (HAp) and shows strong elastic anisotropy. In this study, the effects of HAp on the piezoelectricity were investigated experimentally. To remove the HAp crystallites from the bovine cortical bone, demineralization was performed using ethylene diamine tetra-acetic acid (EDTA) solutions. To investigate the piezoelectricity, we have fabricated ultrasound transducers using the cortical bone or demineralized cortical bone. The induced electrical potentials due to the piezoelectricity were observed as the output of these transducers under pulsed ultrasound irradiation in the MHz range. The cortical bone transducer (before mineralization) showed anisotropic piezoelectric behavior. When the ultrasound irradiation was applied normal to the transducer surface, the observed induced electrical potentials had minimum values. The potential increased under off-axis ultrasound irradiation with changes in polarization. In the demineralized bone transducer case, however, the anisotropic behavior was not observed in the induced electrical potentials. These results therefore indicate that the HAp crystallites affect the piezoelectric characteristics of bone.
Pulmonary ultrasound elastography: a feasibility study with phantoms and ex-vivo tissue
NASA Astrophysics Data System (ADS)
Nguyen, Man Minh; Xie, Hua; Paluch, Kamila; Stanton, Douglas; Ramachandran, Bharat
2013-03-01
Elastography has become widely used for minimally invasive diagnosis in many tumors as seen with breast, liver and prostate. Among different modalities, ultrasound-based elastography stands out due to its advantages including being safe, real-time, and relatively low-cost. While lung cancer is the leading cause of cancer mortality among both men and women, the use of ultrasound elastography for lung cancer diagnosis has hardly been investigated due to the limitations of ultrasound in air. In this work, we investigate the use of static-compression based endobronchial ultrasound elastography by a 3D trans-oesophageal echocardiography (TEE) transducer for lung cancer diagnosis. A water-filled balloon was designed to 1) improve the visualization of endobronchial ultrasound and 2) to induce compression via pumping motion inside the trachea and bronchiole. In a phantom study, we have successfully generated strain images indicating the stiffness difference between the gelatin background and agar inclusion. A similar strain ratio was confirmed with Philips ultrasound strain-based elastography product. For ex-vivo porcine lung study, different tissue ablation methods including chemical injection, Radio Frequency (RF) ablation, and direct heating were implemented to achieve tumor-mimicking tissue. Stiff ablated lung tissues were obtained and detected with our proposed method. These results suggest the feasibility of pulmonary elastography to differentiate stiff tumor tissue from normal tissue.
Hoffman, Caroline S; Messer, Lynne C; Mendola, Pauline; Savitz, David A; Herring, Amy H; Hartmann, Katherine E
2008-11-01
Reported last menstrual period (LMP) is commonly used to estimate gestational age (GA) but may be unreliable. Ultrasound in the first trimester is generally considered a highly accurate method of pregnancy dating. The authors compared first trimester report of LMP and first trimester ultrasound for estimating GA at birth and examined whether disagreement between estimates varied by maternal and infant characteristics. Analyses included 1867 singleton livebirths to women enrolled in a prospective pregnancy cohort. The authors computed the difference between LMP and ultrasound GA estimates (GA difference) and examined the proportion of births within categories of GA difference stratified by maternal and infant characteristics. The proportion of births classified as preterm, term and post-term by pregnancy dating methods was also examined. LMP-based estimates were 0.8 days (standard deviation = 8.0, median = 0) longer on average than ultrasound estimates. LMP classified more births as post-term than ultrasound (4.0% vs. 0.7%). GA difference was greater among young women, non-Hispanic Black and Hispanic women, women of non-optimal body weight and mothers of low-birthweight infants. Results indicate first trimester report of LMP reasonably approximates gestational age obtained from first trimester ultrasound, but the degree of discrepancy between estimates varies by important maternal characteristics.
Ultrasound determination of rotator cuff tear repairability
Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa
2015-01-01
Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996
Sun, Jianxia; Li, Xinghua; Lin, Xinyu; Mei, Zhouxiong; Li, Yitao; Ding, Lijun; Bai, Weibin
2017-03-01
As an alternative preservation method for thermal treatment, ultrasound comprises a novel non-thermal processing technology that can significantly avoid undesirable nutritional changes. However, the recent literature indicates that anthocyanin degradation occurs when ultrasound is applied in juice at high amplitude parameters. Such work has mainly focussed on the effect of ultrasound on stability, the antioxidant capacity of cyanidin-3-glucosylrutinoside (Cy-3-glc-rut) and the correlation between anthocyanin degradation and ·OH generation in a simulated system. The spectral intensities of Cy-3-glc-rut at 518 and 282 nm decreased with increasing ultrasound power and treatment time. The degradation of Cy-3-glc-rut was consistent with first-order reaction kinetics (r 2 > 0.9000) and there was a good linear correlation between anthocyanin degradation and hydroxyl radical formation induced by ultrasound (r 2 = 0.9258). Moreover, a decrease in the antioxidant activity of Cy-3-glc-rut after ultrasound evaluated by the 1,1-diphenyl-2-picrylhydrazyl and ferric reducing antioxidant power methods was observed. Overall, the results of the present study show that ultrasound will accelerate the degradation of Cy-3-glc-rut with the growth of power over time. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Kröner, Anke; Binnekade, Jan M; Graat, Marleen E; Vroom, Margreeth B; Stoker, Jaap; Spronk, Peter E; Schultz, Marcus J
2008-01-01
Elimination of daily-routine chest radiographs (CXRs) may influence chest computed tomography (CT) and ultrasound practice in critically ill patients. This was a retrospective cohort study including all patients admitted to a university-affiliated intensive care unit during two consecutive periods of 5 months, one before and one after elimination of daily-routine CXR. Chest CT and ultrasound studies were identified retrospectively by using the radiology department information system. Indications for and the diagnostic/therapeutic yield of chest CT and ultrasound studies were collected. Elimination of daily-routine CXR resulted in a decrease of CXRs per patient day from 1.1 +/- 0.3 to 0.6 +/- 0.4 (P < 0.05). Elimination did not affect duration of stay or mortality rates. Neither the number of chest CT studies nor the ratio of chest CT studies per patient day changed with the intervention: Before elimination of daily-routine CXR, 52 chest CT studies were obtained from 747 patients; after elimination, 54 CT studies were obtained from 743 patients. Similarly, chest ultrasound practice was not affected by the change of CXR strategy: Before and after elimination, 21 and 27 chest ultrasound studies were performed, respectively. Also, timing of chest CT and ultrasound studies was not different between the two study periods. During the two periods, 40 of 106 chest CT studies (38%) and 18 of 48 chest ultrasound studies (38%) resulted in a change in therapy. The combined therapeutic yield of chest CT and ultrasound studies did not change with elimination of daily-routine CXR. Elimination of daily-routine CXRs may not affect chest CT and ultrasound practice in a multidisciplinary intensive care unit.
NASA Astrophysics Data System (ADS)
Mehrmohammadi, Mohammad; Ma, Li L.; Chen, Yun-Sheng; Qu, Min; Joshi, Pratixa; Chen, Raeanna M.; Johnston, Keith P.; Emelianov, Stanislav
2010-02-01
Photothermal therapy is a laser-based non-invasive technique for cancer treatment. Photothermal therapy can be enhanced by employing metal nanoparticles that absorb the radiant energy from the laser leading to localized thermal damages. Targeting of nanoparticles leads to more efficient uptake and localization of photoabsorbers thus increasing the effectiveness of the treatment. Moreover, efficient targeting can reduce the required dosage of photoabsorbers; thereby reducing the side effects associated with general systematic administration of nanoparticles. Magnetic nanoparticles, due to their small size and response to an external magnetic field gradient have been proposed for targeted drug delivery. In this study, we investigate the applicability of multifunctional nanoparticles (e.g., magneto-plasmonic nanoparticles) and magneto-motive ultrasound imaging for image-guided photothermal therapy. Magneto-motive ultrasound imaging is an ultrasound based imaging technique capable of detecting magnetic nanoparticles indirectly by utilizing a high strength magnetic field to induce motion within the magnetically labeled tissue. The ultrasound imaging is used to detect the internal tissue motion. Due to presence of the magnetic component, the proposed multifunctional nanoparticles along with magneto-motive ultrasound imaging can be used to detect the presence of the photo absorbers. Clearly the higher concentration of magnetic carriers leads to a monotonic increase in magneto-motive ultrasound signal. Thus, magnetomotive ultrasound can determine the presence of the hybrid agents and provide information about their location and concentration. Furthermore, the magneto-motive ultrasound signal can indicate the change in tissue elasticity - a parameter that is expected to change significantly during the photothermal therapy. Therefore, a comprehensive guidance and assessment of the photothermal therapy may be feasible through magneto-motive ultrasound imaging and magnetoplasmonic nanoparticles.
Poliachik, Sandra L.; Khokhlova, Tatiana D.; Wang, Yak-Nam; Simon, Julianna C.; Bailey, Michael R.
2015-01-01
Bone loss can result from bed rest, space flight, spinal cord injury or age-related hormonal changes. Current bone loss mitigation techniques include pharmaceutical interventions, exercise, pulsed ultrasound targeted to bone and whole body vibration. In this study, we attempted to mitigate paralysis-induced bone loss by applying focused ultrasound to the midbelly of a paralyzed muscle. We employed a mouse model of disuse that uses onabotulinumtoxinA-induced paralysis, which causes rapid bone loss in 5 d. A focused 2 MHz transducer applied pulsed exposures with pulse repetition frequency mimicking that of motor neuron firing during walking (80 Hz), standing (20 Hz), or the standard pulsed ultrasound frequency used in fracture healing (1 kHz). Exposures were applied daily to calf muscle for 4 consecutive d. Trabecular bone changes were characterized using micro-computed tomography. Our results indicated that application of certain focused pulsed ultrasound parameters was able to mitigate some of the paralysis-induced bone loss. PMID:24857416
NASA Astrophysics Data System (ADS)
Kudo, Nobuki; Yamamoto, Masaya
2011-09-01
It is known that use of a contrast agents in echocardiography increases the probability of generation of premature ventricular contractions (PVCs). As a basic study to elucidate the mechanisms and to reduce adverse effects, the generation of PVCs was investigated using cultured cardiac myocytes instead of the intact heart in vivo. Cardiac myocytes were isolated from neonatal rats and cultured on a cover slip. The myocyte sample was exposed to pulsed ultrasound with microbubbles adjacent to the myocytes, and generation of PVCs was examined with ultrasound exposure at various delay times after onset of myocyte contraction. The experimental results showed that generation of PVCs had a stable threshold delay time and that PVCs were generated only when myocytes were exposed to ultrasound with delay times longer than the threshold. The results indicate that the model used in this study is useful for revealing the mechanisms by which PVCs are induced by ultrasound exposure.
Kurmanavicius, J; Huch, R; Huch, A
1993-02-01
The advantage of using a computer to automate routine calculations and print out charts of the obstetrical ultrasound examination is obvious. This report describes a software designed to simplify the documentation and analysis of ultrasound data in obstetrics. The system is easy to use, even for persons with little computer knowledge. The programme was written in FoxBase+/Mac (Fox Software, Inc., USA). FoxBase+/Mac takes full advantage of the easy-to-learn, easy-to-use Macintosh interface and is also very fast. Another advantage of this software is that it can be used in teaching. Non-experienced examinators can double-check the correctness of their scanning planes by observing the ultrasound pictures with the markers indicating the right measurement sites and the lists of standard values of biometrical parameters for the corresponding gestational age on the screen. In routine obstetrical ultrasound examinations it takes less than 5 min to enter the foetal biometry data and print out reports. These reports are informative and easy to interpret.
NASA Astrophysics Data System (ADS)
Xiong, Wenli; Wang, Pan; Hu, Jianmin; Jia, Yali; Wu, Lijie; Chen, Xiyang; Liu, Quanhong; Wang, Xiaobing
2015-12-01
Sonodynamic therapy (SDT) was developed as a promising noninvasive approach. The present study investigated the antitumor effect of a new sensitizer (sinoporphyrin sodium, referred to as DVDMS) combined with multiple ultrasound treatments on sarcoma 180 both in vitro and in vivo. The combined treatment significantly suppressed cell viability, potentiated apoptosis, and markedly inhibited angiogenesis in vivo. In vivo, the tumor weight inhibition ratio reached 89.82% fifteen days after three sonication treatments plus DVDMS. This effect was stronger than one ultrasound alone (32.56%) and than one round of sonication plus DVDMS (59.33%). DVDMS combined with multiple focused ultrasound treatments initiated tumor tissue destruction, induced cancer cell apoptosis, inhibited tumor angiogenesis, suppressed cancer cell proliferation, and decreased VEGF and PCNA expression levels. Moreover, the treatment did not show obvious signs of side effects or induce a drop in body weight. These results indicated that DVDMS combined with multiple focused ultrasounds may be a promising strategy against solid tumor.
Akagi, Ryota; Kusama, Saki
2015-08-01
The goals of this study were to compare neck and shoulder stiffness values determined by shear wave ultrasound elastography with those obtained with a muscle hardness meter and to verify the correspondence between objective and subjective stiffness in the neck and shoulder. Twenty-four young men and women participated in the study. Their neck and shoulder stiffness was determined at six sites. Before the start of the measurements, patients rated their present subjective symptoms of neck and shoulder stiffness on a 6-point verbal scale. At all measurement sites, the correlation coefficients between the values of muscle hardness indices determined by the muscle hardness meter and shear wave ultrasound elastography were not significant. Furthermore, individuals' subjective neck and shoulder stiffness did not correspond to their objective symptoms. These results suggest that the use of shear wave ultrasound elastography is essential to more precisely assess neck and shoulder stiffness. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Species-Independent Modeling of High-Frequency Ultrasound Backscatter in Hyaline Cartilage.
Männicke, Nils; Schöne, Martin; Liukkonen, Jukka; Fachet, Dominik; Inkinen, Satu; Malo, Markus K; Oelze, Michael L; Töyräs, Juha; Jurvelin, Jukka S; Raum, Kay
2016-06-01
Apparent integrated backscatter (AIB) is a common ultrasound parameter used to assess cartilage matrix degeneration. However, the specific contributions of chondrocytes, proteoglycan and collagen to AIB remain unknown. To reveal these relationships, this work examined biopsies and cross sections of human, ovine and bovine cartilage with 40-MHz ultrasound biomicroscopy. Site-matched estimates of collagen concentration, proteoglycan concentration, collagen orientation and cell number density were employed in quasi-least-squares linear regression analyses to model AIB. A positive correlation (R(2) = 0.51, p < 10(-4)) between AIB and a combination model of cell number density and collagen concentration was obtained for collagen orientations approximately perpendicular (>70°) to the sound beam direction. These findings indicate causal relationships between AIB and cartilage structural parameters and could aid in more sophisticated future interpretations of ultrasound backscatter. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Novel chitosan derivative for temperature and ultrasound dual-sensitive liposomal microbubble gel.
Chen, Daquan; Yu, Hongyun; Mu, Hongjie; Wei, Junhua; Song, Zhenkun; Shi, Hong; Liang, Rongcai; Sun, Kaoxiang; Liu, Wanhui
2013-04-15
In this study, a novel liposome-loaded microbubble gel based on N-cholesteryl hemisuccinate-O-sulfate chitosan (NCHOSC) was designed. The structure of the NCHOSC was characterized by FTIR and (1)H NMR. The liposomal microbubble gel based on NCHOSC with a high encapsulation efficiency of curcumin was formed and improved the solubility of curcumin. The diameter of most liposomal microbubble was about 950 nm. The temperature-sensitive CS/GP gel could be formulated at room temperature and would form a gel at body temperature. Simultaneously, the ultrasound-sensitive induced release of curcumin was 85% applying ultrasound. The results of cytotoxicity assay indicated that encapsulated curcumin in Cur-LM or Cur-LM-G was less toxic. The anti-tumor efficacy in vivo suggested that Cur-LM-G by ultrasound suppressed tumor growth most efficiently. These findings have shed some light on the potential NCHOSC material used to liposome-loaded microbubble gel for temperature and ultrasound dual-sensitive drug delivery. Copyright © 2013 Elsevier Ltd. All rights reserved.
Minimum anesthetic volume in regional anesthesia by using ultrasound-guidance.
Di Filippo, Alessandro; Falsini, Silvia; Adembri, Chiara
2016-01-01
The ultrasound guidance in regional anesthesia ensures the visualization of needle placement and the spread of Local Anesthetics. Over the past few years there was a substantial interest in determining the Minimum Effective Anesthetic Volume necessary to accomplish surgical anesthesia. The precise and real-time visualization of Local Anesthetics spread under ultrasound guidance block may represent the best requisite for reducing Local Anesthetics dose and Local Anesthetics-related effects. We will report a series of studies that have demonstrated the efficacy of ultrasound guidance blocks to reduce Local Anesthetics and obtain surgical anesthesia as compared to block performed under blind or electrical nerve stimulation technique. Unfortunately, the results of studies are widely divergent and not seem to indicate a dose considered effective, for each block, in a definitive way; but it is true that, through the use of ultrasound guidance, it is possible to reduce the dose of anesthetic in the performance of anesthetic blocks. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Ultrasound-Guided Steroid Injection of the Pisotriquetral Joint: A Multidisciplinary Effort.
Brose, Steven W; Montfort, Janel; Gustafson, Kenneth J; Mittebrun, Ionica; Gauriloff, Samantha; Mosher, Mary; Bourbeau, Dennis J
2017-12-01
From the perspective of a multidisciplinary team, the authors describe the first reported use of ultrasound guidance for steroid injection into the pisotriquetral joint to relieve wrist pain of a person with spinal cord injury undergoing acute inpatient rehabilitation. Musculoskeletal ultrasound guidance was used to improve the accuracy of a corticosteroid injection of the pisotriquetral joint and the basal thumb in a 70-year-old man with paraplegia experiencing multifocal degenerative wrist pain. There was no bleeding or bruising after the injections, and the patient reported complete pain resolution 1 wk after the injections, which continued for over 1 yr. A multidisciplinary team was key in diagnosis, selection of treatment, and evaluation of treatment effect. Corticosteroid injection of the pisotriquetral joint under ultrasound guidance can be used as a treatment modality for managing wrist pain stemming from that joint. Further investigation and studies evaluating the use of ultrasound versus other imaging modalities for injection of the wrist are indicated.
Chronic hypoxia alters maternal uterine and fetal hemodynamics in the full-term pregnant guinea pig.
Turan, Sifa; Aberdeen, Graham W; Thompson, Loren P
2017-10-01
Placental hypoxia is associated with maternal hypertension, placental insufficiency, and fetal growth restriction. In the pregnant guinea pig, prenatal hypoxia during early gestation inhibits cytotrophoblast invasion of spiral arteries, increases maternal blood pressure, and induces fetal growth restriction. In this study the impact of chronic maternal hypoxia on fetal heart structure was evaluated using four-dimensional echocardiography with spatiotemporal image correlation and tomographic ultrasound, and uterine and umbilical artery resistance/pulsatility indexes and fetal heart function were evaluated using pulsed-wave Doppler ultrasound. Pregnant guinea pigs were exposed to normoxia ( n = 7) or hypoxia (10.5% O 2 , n = 9) at 28-30 days gestation, which was maintained until full term (65 days). At full term, fetal heart structure and outflow tracts were evaluated in the four-chamber view. Fetal heart diastolic function was assessed by E wave-to-A wave diastolic filling ratios (E/A ratios) of both ventricles and systolic function by the myocardial performance index (or Tie) of left ventricles of normoxic ( n = 21) and hypoxic ( n = 17) fetuses. There were no structural abnormalities in fetal hearts. However, hypoxia induced asymmetric fetal growth restriction and increased the placental/fetal weight compared with normoxic controls. Hypoxia increased Doppler resistance and pulsatility indexes in the uterine, but not umbilical, arteries, had no effect on the Tie index, and increased the E/A ratio in left, but not right, ventricles. Thus, prolonged hypoxia, starting at midgestation, increases uterine artery resistance and generates fetal growth restriction at full term. Furthermore, the enhanced cardiac diastolic filling with no changes in systolic function or umbilical artery resistance suggests that the fetal guinea pig systemic circulation undergoes a compensated, adaptive response to prolonged hypoxia exposure. Copyright © 2017 the American Physiological Society.
Wang, Tao; Zhang, Diandian; Sun, Yating; Zhou, Shanshan; Li, Lin; Shao, Jingjing
2018-04-01
A lab-scale ultrasound enhancing Anammox reactor (R1) was established and irradiated once a week by ultrasound with the optimal parameter (frequency of 25 kHz, intensity of 0.2 W cm -2 and exposure time of 3 min) obtained by batch experiments. R1 and the controlled Anammox reactor (R2) without exposure to the ultrasound were operated in parallel. The start-up period of Anammox process (53 days) in R1 was shorter than that (61 days) in R2. The nitrogen loading-enhancing period (day 53-day 135) in R1 was also shorter than that (day 61-day 151) in R2. At the end of the nitrogen loading-enhancing period, NLR (0.76 kg N m -3 d -1 ) and NRR (0.68 kg N m -3 d -1 ) of R1 were both higher than NLR (0.66 kg N m -3 d -1 ) and NRR (0.56 kg N m -3 d -1 ) of R2. Moreover, The stability of Anammox process in R1 was better than that in R2. The results demonstrated that the periodical irradiation of ultrasound enhanced the start-up and operational performance of Anammox reactor. Microbial community analysis indicated that the ultrasound accelerated the microbial succession from some other bacteria to Anammox bacteria so that shorten the start-up period of Anammox process from the conventional activated sludge. It also indicated that the ultrasound strengthened the competitive advantage of Candidatus Kuenenia stuttgartiensis in Anammox bacteria of the mature sludge so as to enhance the nitrogen removal performance of the Anammox reactor under the operation condition of high nitrogen loading. Copyright © 2017 Elsevier B.V. All rights reserved.
[Real-time elastography in the diagnosis of prostate cancer: personal experience].
Romagnoli, Andrea; Autieri, Gaspare; Centrella, Danilo; Gastaldi, Christian; Pedaci, Giuseppe; Rivolta, Lorenzo; Pozzi, Emilio; Anghileri, Alessio; Cerabino, Maurizio; Bianchi, Carlo Maria; Roggia, Alberto
2010-01-01
Prostate cancer is the most common cancer in men. In the future, a significant further increase in the incidence of prostate cancer is expected. The indication to perform a prostate biopsy is digital rectal examination suspicious for prostate cancer, total prostate specific antigen (PSA) value, free PSA/total PSA ratio, PSA density and PSA velocity, and an evidence of hypoechoic area at transrectal ultrasound scan. Unfortunately the specificity and sensibility are still poor. The aim of this retrospective study is to evaluate the specificity and sensibility of real time elastography versus ultrasound transrectal B-mode scan. We retrospectively evaluated 108 pts. having undergone TRUS-guided transrectal prostate biopsy (10 samples). The indication for biopsy is: digital rectal examination, total prostate specific antigen (PSA) value, PSA ratio, PSA density and PSA velocity suspicious for prostate cancer, and/or an evidence of hypoechoic area at transrectal ultrasound scan, and/or hard area at real-time elastography. The mean age of patients is 66.8 years, mean PSA 6.5 ng/mL, and mean ratio 16.5%. We compared the histopathological findings of needle prostate biopsies with the results of transrectal ultrasound and transrectal real-time elastography. 32/108 (29.6%) pts. were positive for prostate cancer (mean Gleason score 7.08), mean PSA 14 ng/mL and mean ratio 9.5%. Transrectal ultrasound scan shows a sensibility of 69% and specificity of 68%. Transrectal ultrasound scan shows a VPP of 51.4%. Transrectal ultrasound scan shows a VPN of 80.9%. Real-time elastography shows a sensibility of 56% and specificity of 85.7%. Real-time elastography shows a VPP of 60.1%. Real-time elastography shows a VPN of 83%. Elastography has a significantly higher specificity for the detection of prostate cancer than the conventionally used examinations including DRE and TRUS. It is a useful real-time diagnostic method because it is not invasive, and simultaneous evaluation is possible while performing TRUS.
Seligman, Katherine M; Weiniger, Carolyn F; Carvalho, Brendan
2017-08-30
This study investigated the accuracy of a wireless handheld ultrasound with pattern recognition software that recognizes lumbar spine bony landmarks and measures depth to epidural space (Accuro, Rivanna Medical, Charlottesville, VA) (AU). AU measurements to epidural space were compared to Tuohy needle depth to epidural space (depth to loss of resistance at epidural placement). Data from 47 women requesting labor epidural analgesia were analyzed. The mean difference between depth to epidural space measured by AU versus needle depth was -0.61 cm (95% confidence interval, -0.79 to -0.44), with a standard deviation of 0.58 (95% confidence interval, 0.48-0.73). Using the AU-identified insertion point resulted in successful epidural placement at first attempt in 87% of patients, 78% without redirects.
Griffin, Nick M R; Wright, Isabel A; Buckenham, Tim M
2006-11-01
Postoperative surveillance of infra-inguinal vein grafts has arisen because of the high incidence of vein graft stenoses, which frequently progress to vein graft occlusion. The use of duplex ultrasound as the primary imaging method for graft surveillance is well established. This study aims to compare the accuracy of duplex ultrasound with the reference standard of digital subtraction angiography in the assessment of infra-inguinal vein grafts. Sixty patients underwent routine postoperative duplex ultrasound as part of the local graft surveillance programme. Angiography was subsequently carried out on 18 grafts. Each lower limb arterial tree was divided into three segments (native arteries proximal to the graft, the graft itself and native arteries distal to the graft) resulting in a total of 42 comparisons. Degree of diameter stenosis on ultrasound was compared with angiography findings to determine concordance. Agreement was also expressed as a kappa value. Overall accuracy of duplex ultrasound was 88% (37/42). A kappa value of 0.80 indicates good agreement. In three of the five discordant cases, ultrasound correctly identified a stenosis, but overestimated the degree of stenosis compared with angiography. In each of the remaining two discordant cases, ultrasound identified a focal stenosis that was not apparent on angiography. In both cases, the area of duplex described abnormality responded to balloon angioplasty. Duplex ultrasound as part of the local vein graft surveillance programme is a reliable and accurate method in the detection of failing grafts and in some instances may be more sensitive.
Rocher, Laurence; Ramchandani, Parvati; Belfield, Jane; Bertolotto, Michele; Derchi, Lorenzo E; Correas, Jean Michel; Oyen, Raymond; Tsili, Athina C; Turgut, Ahmet Tuncay; Dogra, Vikram; Fizazi, Karim; Freeman, Simon; Richenberg, Jonathan
2016-07-01
The increasing detection of small testicular lesions by ultrasound (US) in adults can lead to unnecessary orchiectomies. This article describes their nature, reviews the available literature on this subject and illustrates some classical lesions. We also suggest recommendations to help characterization and management. The ESUR scrotal imaging subcommittee searched for original and review articles published before May 2015 using the Pubmed and Medline databases. Key words used were 'testicular ultrasound', 'contrast-enhanced sonography', 'sonoelastography', 'magnetic resonance imaging', 'testis-sparing surgery', 'testis imaging', 'Leydig cell tumour', 'testicular cyst'. Consensus was obtained amongst the members of the subcommittee, urologist and medical oncologist. Simple cysts are frequent and benign, and do not require follow up or surgery. Incidentally discovered small solid testicular lesions detected are benign in up to 80 %, with Leydig cell tumours being the most frequent. However, the presence of microliths, macrocalcifications and hypoechoic areas surrounding the nodule are findings suggestive of malignant disease. Asymptomatic small testicular lesions found on ultrasound are mainly benign, but findings such as microliths or hypoechoic regions surrounding the nodules may indicate malignancy. Colour Doppler US remains the basic examination for characterization. The role of newer imaging modalities in characterization is evolving. • Characterization of testicular lesions is primarily based on US examination. • The role of MRI, sonoelastography, contrast-enhanced ultrasound is evolving. • Most small non-palpable testicular lesions seen on ultrasound are benign simple cysts. • Leydig cell tumours are the most frequent benign lesions. • Associated findings like microliths or hypoechoic regions may indicate malignancy.
Jones, A K; Gately, R E; McFadden, K K; Hoffman, M L; Pillai, S M; Zinn, S A; Govoni, K E; Reed, S A
2017-08-01
To determine the effects of poor maternal nutrition and litter size on foetal growth during mid-gestation, pregnant ewes (n = 82) were fed 100%, 60% or 140% of NRC TDN beginning at day 30.2 ± 0.2 of gestation. Transabdominal ultrasound was performed weekly between day 46.0 ± 0.4 and 86.0 ± 0.7 to monitor foetal heart width (HW), umbilical diameter (UMB), rib width (RW) and placentome outer (OD) and inner diameter (ID). Data were analysed with repeated-measures using the mixed procedure for effects of maternal diet, litter size and gestation, and equations predictive of gestational age were generated using the regression procedure. To determine the agreement of ultrasound measurement and actual size, ewes (n = 20-21) were euthanized at day 45 or 90 to obtain corresponding postmortem measurements for Bland-Altman analysis. The HW, UMB and placentome OD and ID increased with gestation (p < .0001) but were unaffected by maternal diet or litter size (p ≥ .12). Ultrasound underestimated postmortem measurements of HW (14.8%), UMB (7.3%), placentome OD (4.5%) and ID (37.3%) at day 90 of gestation. Ultrasound underestimated RW at day 45 (7.7%) but overestimated RW (23.8%) at day 90, indicating inconsistent bias when reporting RW by ultrasound. Combining the HW, UMB, RW and placentome OD generated the strongest equation predictive of gestational age (R 2 = .91). These findings indicate that during mid-gestation, maternal diet or litter size did not affect HW, UMB or placentome diameters and these factors can be used to estimate gestational age. © 2017 Blackwell Verlag GmbH.
Ultrasound active nanoscaled lipid formulations for thrombus lysis.
Becker, Andreas; Marxer, Elena; Brüssler, Jana; Hoormann, Anne Sophia; Kuhnt, Daniela; Bakowsky, Udo; Nimsky, Christopher
2011-04-01
In the present study, we investigated the sonothrombolytic effect of new nanoscaled lipid formulations in human blood clots, using diagnostic ultrasound. Human blood clots of 1 ml were incubated with 1 μl of the different lipid dispersions DPPC/CH, DPPC/PEG40S, DSPC/PEG40S and the commercially available ultrasound contrast agent SonoVue®. Clots were stored for 3 days at 5 °C to obtain maximal clot retraction and lytic resistance. Each clot weight was determined before and after continuous insonation for 1h of insonation at 1.4 MHz. The pressure in the insonation chamber was 80 mm Hg to mimic middle arterial blood pressure. There were no significant differences in thrombus weight before insonation. All nanoscaled formulations and SonoVue® were able to reduce thrombus weight compared to the weight loss of clots that were not insonated but kept under pressure for one hour (p < 0.001). We found a highly significant weight reduction with DSPC/PEG40S compared to SonoVue® (p = 0.007). Nanoscaled DSPC/PEG40S dispersion could be a promising formulation in ultrasound enhanced thrombolysis even without thrombolytic drugs. Stable cavitation is a crucial parameter in fragmentation of thrombus architecture. Further studies of physicochemical properties of DSPC/PEG40S are necessary to corroborate our hypothesis. Copyright © 2010 Elsevier B.V. All rights reserved.
Joy, Jordan M; Falcone, Paul H; Vogel, Roxanne M; Mosman, Matt M; Kim, Michael P; Moon, Jordan R
2015-11-01
Adenosine-5'-triphosphate (ATP) is primarily known as a cellular source of energy. Increased ATP levels may have the potential to enhance body composition. A novel, proprietary blend of ancient peat and apple extracts has been reported to increase ATP levels, potentially by enhancing mitochondrial ATP production. Therefore, the purpose of this investigation was to determine the supplement's effects on body composition when consumed during 12 weeks of resistance training. Twenty-five healthy, resistance-trained, male subjects (age, 27.7 ± 4.8 years; height, 176.0 ± 6.5 cm; body mass, 83.2 ± 12.1 kg) completed this study. Subjects supplemented once daily with either 1 serving (150 mg) of a proprietary blend of ancient peat and apple extracts (TRT) or placebo (PLA). Supervised resistance training consisted of 8 weeks of daily undulating periodized training followed by a 2-week overreach and a 2-week taper phase. Body composition was assessed using dual-energy X-ray absorptiometry and ultrasound at weeks 0, 4, 8, 10, and 12. Vital signs and blood markers were assessed at weeks 0, 8, and 12. Significant group × time (p < 0.05) interactions were present for ultrasound-determined cross-sectional area, which increased in TRT (+0.91 cm(2)) versus PLA (-0.08 cm(2)), as well as muscle thickness (TRT: +0.46; PLA: +0.04 cm). A significant group × time (p < 0.05) interaction existed for creatinine (TRT: +0.06; PLA: +0.15 mg/dL), triglycerides (TRT: +24.1; PLA: -20.2 mg/dL), and very-low-density lipoprotein (TRT: +4.9; PLA: -3.9 mg/dL), which remained within clinical ranges. Supplementation with a proprietary blend of ancient peat and apple extracts may enhance resistance training-induced skeletal muscle hypertrophy without affecting fat mass or blood chemistry in healthy males.
Dückelmann, A M; Bamberg, C; Michaelis, S A M; Lange, J; Nonnenmacher, A; Dudenhausen, J W; Kalache, K D
2010-02-01
To assess whether ultrasound experience or fetal head station affects the reliability of measurement of fetal head descent using the angle of progression on intrapartum ultrasound images obtained by a single experienced operator, and to determine reliability of measurements when images were acquired by different operators with variable ultrasound experience. One experienced obstetrician performed 44 transperineal ultrasound examinations of women at term and in prolonged second stage of labor with the fetus in the occipitoanterior position. Three midwives without ultrasound experience, three obstetricians with < 5 years' experience and three obstetricians with > 10 years' experience measured fetal head descent based on the angle of progression in the images obtained. The angle of progression was measured by two obstetricians in independent ultrasound examinations of 24 laboring women at term with the fetus in the cephalic position to allow assessment of the reliability of image acquisition. Intraclass correlation coefficients (ICCs) with 95% confidence interval (CI) were used to evaluate interobserver reliability and Bland-Altman analysis was used to assess interobserver agreement. In total, 444 measurements were performed and compared. Interobserver reliability with respect to offline image analysis was substantial (overall ICC, 0.72; 95% CI, 0.63-0.81). ICCs were 0.82 (95% CI, 0.70-0.89), 0.81 (95% CI, 0.71-0.88) and 0.61 (95% CI, 0.43-074) for observers with > 10 years', < 5 years' and no ultrasound experience, respectively. There were no significant differences between ICCs among observer groups according to ultrasound experience. Fetal head station did not affect reliability. Bland-Altman analysis indicated reasonable agreement between measurements obtained by two different operators with > 10 years' and < 5 years' ultrasound experience (bias, -1.09 degrees ; 95% limits of agreement, -8.76 to 6.58). The reliability of measurement of the angle of progression following separate image acquisition by two experienced operators was similar to the reliability of offline image analysis (ICC, 0.86; 95% CI, 0.70-0.93). Measurement of the angle of progression on transperineal ultrasound imaging is reliable regardless of fetal head station or the clinician's level of ultrasound experience.
Manipulating neuronal activity with low frequency transcranial ultrasound
NASA Astrophysics Data System (ADS)
Moore, Michele Elizabeth
Stimulation of the rodent cerebral cortex is used to investigate the underlying biological basis for the restorative effects of slow wave sleep. Neuronal activation by optogenetic and ultrasound stimulation elicits changes in action potentials across the cerebral cortex that are recorded as electroencephalograms. Optogenetic stimulation requires an invasive implantation procedure limiting its application in human studies. We sought to determine whether ultrasound stimulation could be as effective as optogenetic techniques currently used, in an effort to further understand the physiological and metabolic requirements of sleep. We successfully recorded electroencephalograms in response to transcranial ultrasound stimulation of the barrel cortex at 1 and 7 Hz frequencies, comparing them to those recorded in response to optogenetic stimuli applied at the same frequencies. Our results showed application of a 473 nm blue LED positioned 6 cm above the skull and ultrasound stimulation at an output voltage of 1000 mVpp produced electroencephalograms with physiological responses of similar amplitude. We concluded that there exists an intensity-proportionate response in the optogenetic stimulation, but not with ultrasound stimulation at the frequencies we surveyed. Activation of neuronal cells in response to optogenetic stimulation in a Thy1-ChR2 transgenic mouse line is specifically targeted to pyramidal cells in the cerebral cortex. ChR2 responses to optogenetic stimulation are mediated by a focal activation of neuronal ion channels. We measured electrophysiological responses to ultrasound stimulation, comparing them to those recorded from optogenetic stimuli. Our results show striking similarities between ultrasound-induced responses and optogenetically-induced responses, which may indicate that transcranial ultrasound stimulation is also mediated by ion channel dependent processes in cerebral cortical neurons. The biophysical substrates for electrical excitability of neurons impose temporal constraints on their response to stimulation. If ultrasound-mediated responses are, in fact, ion channel mediated responses, ultrasound-induced responses should exhibit time-dependence characteristics similar to those of optogenetically-triggered responses. Minimal stimulus duration thresholds and the temporal limits of paired pulse facilitation for ultrasound stimulation were identical to those of optogenetic stimulation. Collectively, these experiments demonstrate an electrophysiological basis for low-frequency transcranial ultrasound stimulation of cerebral cortical neuronal activity.
NASA Astrophysics Data System (ADS)
Kaczkowski, Peter J.; Anand, Ajay
2005-09-01
The spatial distribution and temporal history of tissue temperature is an essential indicator of thermal therapy progress, and treatment safety and efficacy. Magnetic resonance methods provide the gold standard noninvasive measurement of temperature but are costly and cumbersome compared to the therapy itself. We have been developing the use of ultrasound backscattering for real-time temperature estimation; ultrasonic methods have been limited to relatively low temperature rise, primarily due to lack of sensitivity at protein denaturation temperatures (50-70
Correlation between ultrasound velocity and densitometry in fresh and demineralized cortical bone
de Mesquita, Alessandro Queiroz; Barbieri, Giuliano; Barbieri, Claudio Henrique
2016-01-01
OBJECTIVE: To compare ultrasound propagation velocity with densitometry in the diaphyseal compact cortical bone of whole sheep metatarsals. METHODS: The transverse ultrasound velocity and bone mineral density of 5-cm-long diaphyseal bone segments were first measured. The bone segments were then divided into four groups of 15 segments each and demineralized in an aqueous 0.5 N hydrochloric acid solution for 6, 12, 24 or 36 hours. All measurements were repeated after demineralization for each time duration and the values measured before and after demineralization were compared. RESULTS: Ultrasound velocity and bone mineral density decreased with demineralization time, and most differences in the pre- and post-demineralization values within each group and between groups were significant: A moderate correlation coefficient (r=0.75956) together with a moderate agreement was determined between both post-demineralization parameters, detected by the Bland-Altman method. CONCLUSION: We conclude that both ultrasound velocity and bone mineral density decrease as a result of demineralization, thus indicating that bone mineral content is of great importance for maintaining the acoustic parameters of cortical bone, as observed for cancellous bone. Ultrasound velocity can be used to evaluate both compact cortical bone quality and bone mineral density. PMID:27982167
Correlation between ultrasound velocity and densitometry in fresh and demineralized cortical bone.
Mesquita, Alessandro Queiroz de; Barbieri, Giuliano; Barbieri, Claudio Henrique
2016-11-01
To compare ultrasound propagation velocity with densitometry in the diaphyseal compact cortical bone of whole sheep metatarsals. The transverse ultrasound velocity and bone mineral density of 5-cm-long diaphyseal bone segments were first measured. The bone segments were then divided into four groups of 15 segments each and demineralized in an aqueous 0.5 N hydrochloric acid solution for 6, 12, 24 or 36 hours. All measurements were repeated after demineralization for each time duration and the values measured before and after demineralization were compared. Ultrasound velocity and bone mineral density decreased with demineralization time, and most differences in the pre- and post-demineralization values within each group and between groups were significant: A moderate correlation coefficient (r=0.75956) together with a moderate agreement was determined between both post-demineralization parameters, detected by the Bland-Altman method. We conclude that both ultrasound velocity and bone mineral density decrease as a result of demineralization, thus indicating that bone mineral content is of great importance for maintaining the acoustic parameters of cortical bone, as observed for cancellous bone. Ultrasound velocity can be used to evaluate both compact cortical bone quality and bone mineral density.
Li, Mei; Li, Ji-Tai; Sun, Han-Wen
2008-07-01
At its natural pH (6.95), the decolorization of Reactive red 24 in ultrasound, ultrasound/H2O2, exfoliated graphite, ultrasound/exfoliated graphite, exfoliated graphite/H2O2 and ultrasound/exfoliated graphite/H2O2 systems were compared. An enhancement was observed for the decolorization in ultrasound/exfoliated graphite/H2O2 system. The effect of solution pH, H2O2 and exfoliated graphite dosages, and temperature on the decolorization of Reactive red 24 was investigated. The sonochemical treatment in combination with exfoliated graphite/H2O2 showed a synergistic effect for the decolorization of Reactive red 24. The results indicated that under proper conditions, there was a possibility to remove Reactive red 24 very efficient from aqueous solution. The decolorization of other azo dyes (Reactive red 2, Methyl orange, Acid red 1, Acid red 73, Acid red 249, Acid orange 7, Acid blue 113, Acid brown 75, Acid green 20, Acid yellow 42, Acid mordant brown 33, Acid mordant yellow 10 and Direct green 1) was also investigated, at their natural pH.
Microbubble and ultrasound radioenhancement of bladder cancer
Tran, W T; Iradji, S; Sofroni, E; Giles, A; Eddy, D; Czarnota, G J
2012-01-01
Background: Tumour vasculature is an important component of tumour growth and survival. Recent evidence indicates tumour vasculature also has an important role in tumour radiation response. In this study, we investigated ultrasound and microbubbles to enhance the effects of radiation. Methods: Human bladder cancer HT-1376 xenografts in severe combined immuno-deficient mice were used. Treatments consisted of no, low and high concentrations of microbubbles and radiation doses of 0, 2 and 8 Gy in short-term and longitudinal studies. Acute response was assessed 24 h after treatment and longitudinal studies monitored tumour response weekly up to 28 days using power Doppler ultrasound imaging for a total of 9 conditions (n=90 animals). Results: Quantitative analysis of ultrasound data revealed reduced blood flow with ultrasound-microbubble treatments alone and further when combined with radiation. Tumours treated with microbubbles and radiation revealed enhanced cell death, vascular normalisation and areas of fibrosis. Longitudinal data demonstrated a reduced normalised vascular index and increased tumour cell death in both low and high microbubble concentrations with radiation. Conclusion: Our study demonstrated that ultrasound-mediated microbubble exposure can enhance radiation effects in tumours, and can lead to enhanced tumour cell death. PMID:22790798
Dependence of thresholds for pulmonary capillary hemorrhage on diagnostic ultrasound frequency.
Miller, Douglas L; Dou, Chunyan; Raghavendran, Krishnan
2015-06-01
Pulmonary ultrasound examination has become routine for diagnosis in many clinical and point-of-care medical settings. However, the phenomenon of pulmonary capillary hemorrhage (PCH) induction during diagnostic ultrasound imaging presents a poorly understood risk factor. PCH was observed in anesthetized rats exposed to 1.5-, 4.5- and 12.0-MHz diagnostic ultrasound to investigate the frequency dependence of PCH thresholds. PCH was detected in the ultrasound images as growing comet tail artifacts and was assessed using photographs of the surface of excised lungs. Previous photographs acquired after exposure to 7.6-MHz diagnostic ultrasound were included for analysis. In addition, at each frequency we measured dosimetric parameters, including peak rarefactional pressure amplitude and spatial peak, pulse average intensity attenuated by rat chest wall samples. Peak rarefactional pressure amplitude thresholds determined at each frequency, based on the proportion of PCH in groups of five rats, were 1.03 ± 0.02, 1.28 ± 0.14, 1.18 ± 0.12 and 1.36 ± 0.15 MPa at 1.5, 4.5, 7.6 and 12.0 MHz, respectively. Although the PCH lesions decreased in size with increasing ultrasonic frequency, owing to the smaller beam widths and scan lengths, the peak rarefactional pressure amplitude thresholds remained approximately constant. This dependence was different from that of the mechanical index, which indicates a need for a specific dosimetric parameter for safety guidance in pulmonary ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Frequency-dependent ultrasound-induced transformation in E. coli.
Deeks, Jeremy; Windmill, James; Agbeze-Onuma, Maduka; Kalin, Robert M; Argondizza, Peter; Knapp, Charles W
2014-12-01
Ultrasound-enhanced gene transfer (UEGT) is continuing to gain interest across many disciplines; however, very few studies investigate UEGT efficiency across a range of frequencies. Using a variable frequency generator, UEGT was tested in E. coli at six ultrasonic frequencies. Results indicate frequency can significantly influence UEGT efficiency positively and negatively. A frequency of 61 kHz improved UEGT efficiency by ~70 % higher, but 99 kHz impeded UEGT to an extent worse than no ultrasound exposure. The other four frequencies (26, 133, 174, and 190 kHz) enhanced transformation compared to no ultrasound, but efficiencies did not vary. The influence of frequency on UEGT efficiency was observed across a range of operating frequencies. It is plausible that frequency-dependent dynamics of mechanical and chemical energies released during cavitational-bubble collapse (CBC) are responsible for observed UEGT efficiencies.
Wang, Hsing-I; Yang, Ming-Jie; Wang, Peng-Hui; Wu, Yi-Cheng; Chen, Chih-Yao
2014-12-01
The placental volume and vascular indices are crucial in helping doctors to evaluate early fetal growth and development. Inadequate placental volume or vascularity might indicate poor fetal growth or gestational complications. This study aimed to evaluate the placental volume and vascular indices during the period of 11-14 weeks of gestation in a Taiwanese population. From June 2006 to September 2009, three-dimensional power Doppler ultrasound was performed in 222 normal pregnancies from 11-14 weeks of gestation. Power Doppler ultrasound was applied to the placenta and the placental volume was obtained by a rotational technique (VOCAL). The three-dimensional power histogram was used to assess the placental vascular indices, including the mean gray value, the vascularization index, the flow index, and the vascularization flow index. The placental vascular indices were then plotted against gestational age (GA) and placental volume. Our results showed that the linear regression equation for placental volume using gestational week as the independent variable was placental volume = 18.852 × GA - 180.89 (r = 0.481, p < 0.05). All the placental vascular indices showed a constant distribution throughout the period 11-14 weeks of gestation. A tendency for a reduction in the placental mean gray value with gestational week was observed, but without statistical significance. All the placental vascular indices estimated by three-dimensional power Doppler ultrasonography showed a constant distribution throughout gestation. Copyright © 2014. Published by Elsevier Taiwan.
Evaluation of cardiovascular risk in stages of gout by a complex multimodal ultrasonography.
Gancheva, Rada; Kundurdjiev, Atanas; Ivanova, Mariana; Kundurzhiev, Todor; Kolarov, Zlatimir
2017-01-01
The aim of our work was to assess ultrasound features of cardiovascular (CV) risk in stages of gout. Cross-sectional complex multimodal ultrasound study of 169 age-matched patients, with similar distribution of arterial hypertension, diabetes mellitus, obesity and chronic renal failure, was divided into four groups: 41 with asymptomatic hyperuricemia, 52 gout without tophi, 42 gouty tophi and 34 controls with osteoarthritis. Parameters independently associated with CV risk were measured: renal resistive index (RRI), left ventricular mass index (LVMi), mitral annulus early diastolic velocity (e'), intima-media thickness (IMT) and common carotid artery resistive index (CCARI). Multivariate analyses were performed to evaluate the impact of gout stages and CV risk factors on ultrasound alterations. Gouty tophi increased the risk of having IMT >0.90 mm with an OR 11.51 (95 % CI 2.32-57.21, p = 0.003), gout without tophi raised the risk with an OR 6.25 (95 % CI 1.37-28.44, p = 0.018), while asymptomatic hyperuricemia had no effect on IMT. The category of CCARI >0.70 was influenced by tophi with an OR 11.18 (95 % CI 2.61-47.83, p = 0.001) and by arterial hypertension with an OR 3.22 (95 % CI 1.11-9.36, p = 0.032). Neither asymptomatic hyperuricemia nor gout without tophi modified the development of abnormally high CCARI. Gout stages had no impact on LVMi, e' and RRI. Tophi are related to worsened ultrasonographic parameters evaluating target organs in gout, relative to earlier stages of the disease. They create a strong risk of carotid arteries' changes even beyond arterial hypertension.
Sharma, Sachin; Kumar Poddar, Maneesh; Moholkar, Vijayanand S
2017-05-01
This study reports synthesis and characterization of poly(MMA-co-BA)/Cloisite 30B (organo-modified montmorillonite clay) nanocomposites by ultrasound-assisted in-situ emulsion polymerization. Copolymers have been synthesized with MMA:BA monomer ratio of 4:1, and varying clay loading (1-5wt% monomer). The poly(MMA-co-BA)/Cloisite 30B nanocomposites have been characterized for their thermal and mechanical properties. Ultrasonically synthesized nanocomposites have been revealed to possess higher thermal degradation resistance and mechanical strength than the nanocomposites synthesized using conventional techniques. These properties, however, show an optimum (or maxima) with clay loading. The maximum values of thermal and mechanical properties of the nanocomposites with optimum clay loading are as follows. Thermal degradation temperatures: T 10% =320°C (4wt%), T 50 =373°C (4wt%), maximum degradation temperature=384°C (4wt%); glass transition temperature=64.8°C (4wt%); tensile strength=20MPa (2wt%), Young's modulus=1.31GPa (2wt%), Percentage elongation=17.5% (1wt%). Enhanced properties of poly(MMA-co-BA)/Cloisite 30B nanocomposites are attributed to effective exfoliation and dispersion of clay nanoparticles in copolymer matrix due to intense micro-convection induced by ultrasound and cavitation. Clay platelets help in effective heat absorption with maximum surface interaction/adhesion that results in increased thermal resistivity of nanocomposites. Hindered motion of the copolymer chains due to clay platelets results in enhancement of tensile strength and Young's modulus of nanocomposite. Rheological (liquid) study of the nanocomposites reveals that nanocomposites have higher yield stress and infinite shear viscosity than neat copolymer. Nonetheless, nanocomposites still display shear thinning behavior - which is typical of the neat copolymer. Copyright © 2016 Elsevier B.V. All rights reserved.
Kann, P; Schulz, U; Klaus, D; Piepkorn, B; Beyer, J
1995-01-01
The square of ultrasound transmission velocity in a material is related to the modulus of elasticity, which is known to be an indicator of stability in bone. The aim of our study was to use ultrasound transmission velocity to obtain information about the material properties of bone tissue, keeping other factors possibly influencing ultrasound transmission as constant as possible. Apparent phalangeal ultrasound transmission velocity (APU) measured in 54 isolated, fresh pig phalanges was shown to be independent of bone mineral density (BMD) measured by SPA. Fastest sound transmission led exclusively through cortical bone so that intertrabecular connectivity in spongious bone could not influence the result. In humans APU was measured in the mediolateral direction at the midphalanx of the middle finger. In 53 healthy subjects (15-81 years old; 27 women, 26 men), there was a decrease of APU with age (r = -0.30, p < 0.05). Further, when comparing the results of both hands intraindividually almost identical values indicated constant intraindividual architecture of bone at this location. There was no evidence for a relation of APU to physical load comparing dominant and nondominant hand and relating the results to subjectively estimated physical load. In a second group of 43 perimenopausal women (47-60 years old), APU, which again decreased with age (r = -0.33, p < 0.05), was found not to be correlated to BMD measured by SPA at the distal forearm (cortical bone).(ABSTRACT TRUNCATED AT 250 WORDS)
ADV36 adipogenic adenovirus in human liver disease
Trovato, Francesca M; Catalano, Daniela; Garozzo, Adriana; Martines, G Fabio; Pirri, Clara; Trovato, Guglielmo M
2014-01-01
Obesity and liver steatosis are usually described as related diseases. Obesity is regarded as exclusive consequence of an imbalance between food intake and physical exercise, modulated by endocrine and genetic factors. Non-alcoholic fatty liver disease (NAFLD), is a condition whose natural history is related to, but not completely explained by over-nutrition, obesity and insulin resistance. There is evidence that environmental infections, and notably adipogenic adenoviruses (ADV) infections in humans, are associated not only with obesity, which is sufficiently established, but also with allied conditions, such as fatty liver. In order to elucidate the role, if any, of previous ADV36 infection in humans, we investigated association of ADV36-ADV37 seropositivity with obesity and fatty liver in humans. Moreover, the possibility that lifestyle-nutritional intervention in patients with NAFLD and different ADV36 seropositive status, achieves different clinical outcomes on ultrasound bright liver imaging, insulin resistance and obesity was challenged. ADV36 seropositive patients have a more consistent decrease in insulin resistance, fatty liver severity and body weight in comparison with ADV36 seronegative patients, indicating a greater responsiveness to nutritional intervention. These effects were not dependent on a greater pre-interventional body weight and older age. These results imply that no obvious disadvantage - and, seemingly, that some benefit - is linked to ADV36 seropositivity, at least in NAFLD. ADV36 previous infection can boost weight loss and recovery of insulin sensitivity under interventional treatment. PMID:25356033
Kiani, Hossein; Sun, Da-Wen; Delgado, Adriana; Zhang, Zhihang
2012-05-01
Nucleation, as an important stage of freezing process, can be induced by the irradiation of power ultrasound. In this study, the effect of irradiation temperature (-2 °C, -3 °C, -4 °C and -5 °C), irradiation duration (0s, 1s, 3s, 5s, 10s or 15s) and ultrasound intensity (0.07 W cm(-2), 0.14 W cm(-2), 0.25 W cm(-2), 0.35 W cm(-2) and 0.42 W cm(-2)) on the dynamic nucleation of ice in agar gel samples was studied. The samples were frozen in an ethylene glycol-water mixture (-20 °C) in an ultrasonic bath system after putting them into tubing vials. Results indicated that ultrasound irradiation is able to initiate nucleation at different supercooled temperatures (from -5 °C to -2 °C) in agar gel if optimum intensity and duration of ultrasound were chosen. Evaluation of the effect of 0.25 W cm(-2) ultrasound intensity and different durations of ultrasound application on agar gels showed that 1s was not long enough to induce nucleation, 3s induced the nucleation repeatedly but longer irradiation durations resulted in the generation of heat and therefore nucleation was postponed. Investigation of the effect of ultrasound intensity revealed that higher intensities of ultrasound were effective when a shorter period of irradiation was used, while lower intensities only resulted in nucleation when a longer irradiation time was applied. In addition to this, higher intensities were not effective at longer irradiation times due to the heat generated in the samples by the heating effect of ultrasound. In conclusion, the use of ultrasound as a means to control the crystallization process offers promising application in freezing of solid foods, however, optimum conditions should be selected. Copyright © 2011 Elsevier B.V. All rights reserved.
The use of ultrasound in the diagnosis of abdominal wall hernias.
Young, J; Gilbert, A I; Graham, M F
2007-08-01
The diagnosis of abdominal wall hernias is not always straightforward and may require additional investigative modalities. Real-time ultrasound is accurate, non-invasive, relatively inexpensive, and readily available. The value of ultrasound as an adjunctive tool in the diagnosis of abdominal wall hernias in both pre-operative and post-operative patients was studied. Retrospective analysis of 200 patients treated at the Hernia Institute of Florida was carried out. In these cases, ultrasound had been used to assist with case management. Patients without previous hernia surgery and those with early and late post-herniorrhaphy complaints were studied. Patients with obvious hernias were excluded. Indications for ultrasound examination included patients with abdominal pain without a palpable hernia, a palpable mass of questionable etiology, and patients with inordinate pain or excessive swelling during the early post-operative period. Patients were treated with surgery or conservative therapy depending on the results of the physical examination and ultrasound studies. Cases in which the ultrasound findings influenced the decision-making process by confirming clinical findings or altering the diagnosis and changing the treatment plan are discussed. Of the 200 patients, 144 complained of pain alone and on physical exam no hernia or mass was palpable. Of these 144 patients with pain alone, 21 had a hernia identified on the US examination and were referred for surgery. The 108 that had a negative ultrasound were treated conservatively with rest, heat, and anti-inflammatory drugs, most often with excellent results. Of the 56 remaining patients who had a mass, with or without pain, 22 had hernias identified by means of ultrasound examination. In the other 34, the etiology of the mass was not a hernia. Abdominal wall ultrasound is a valuable tool in the scheme of management of patients in whom the diagnosis of abdominal wall hernia is unclear. Therapeutic decisions can be influenced by the ultrasound findings that can provide more efficient and economical treatment by expediting their clinical management.
La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo
2016-01-01
This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases. PMID:27302491
Barile, Antonio; La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo
2016-09-01
This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases.
Externally Delivered Focused Ultrasound for Renal Denervation.
Neuzil, Petr; Ormiston, John; Brinton, Todd J; Starek, Zdenek; Esler, Murray; Dawood, Omar; Anderson, Thomas L; Gertner, Michael; Whitbourne, Rob; Schmieder, Roland E
2016-06-27
The aim of this study was to assess clinical safety and efficacy outcomes of renal denervation executed by an externally delivered, completely noninvasive focused therapeutic ultrasound device. Renal denervation has emerged as a potential treatment approach for resistant hypertension. Sixty-nine subjects received renal denervation with externally delivered focused ultrasound via the Kona Medical Surround Sound System. This approach was investigated across 3 consecutive studies to optimize targeting, tracking, and dosing. In the third study, treatments were performed in a completely noninvasive way using duplex ultrasound image guidance to target the therapy. Short- and long-term safety and efficacy were evaluated through use of clinical assessments, magnetic resonance imaging scans prior to and 3 and 24 weeks after renal denervation, and, in cases in which a targeting catheter was used to facilitate targeting, fluoroscopic angiography with contrast. All patients tolerated renal denervation using externally delivered focused ultrasound. Office blood pressure (BP) decreased by 24.6 ± 27.6/9.0 ± 15.0 mm Hg (from baseline BP of 180.0 ± 18.5/97.7 ± 13.7 mm Hg) in 69 patients after 6 months and 23.8 ± 24.1/10.3 ± 13.1 mm Hg in 64 patients with complete 1-year follow-up. The response rate (BP decrease >10 mm Hg) was 75% after 6 months and 77% after 1 year. The most common adverse event was post-treatment back pain, which was reported in 32 of 69 patients and resolved within 72 h in most cases. No intervention-related adverse events involving motor or sensory deficits were reported. Renal function was not altered, and vascular safety was established by magnetic resonance imaging (all patients), fluoroscopic angiography (n = 48), and optical coherence tomography (n = 5). Using externally delivered focused ultrasound and noninvasive duplex ultrasound, image-guided targeting was associated with substantial BP reduction without any major safety signals. Further randomized, sham-controlled trials will be needed to validate this unique approach. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Numerical simulations of clinical focused ultrasound functional neurosurgery
NASA Astrophysics Data System (ADS)
Pulkkinen, Aki; Werner, Beat; Martin, Ernst; Hynynen, Kullervo
2014-04-01
A computational model utilizing grid and finite difference methods were developed to simulate focused ultrasound functional neurosurgery interventions. The model couples the propagation of ultrasound in fluids (soft tissues) and solids (skull) with acoustic and visco-elastic wave equations. The computational model was applied to simulate clinical focused ultrasound functional neurosurgery treatments performed in patients suffering from therapy resistant chronic neuropathic pain. Datasets of five patients were used to derive the treatment geometry. Eight sonications performed in the treatments were then simulated with the developed model. Computations were performed by driving the simulated phased array ultrasound transducer with the acoustic parameters used in the treatments. Resulting focal temperatures and size of the thermal foci were compared quantitatively, in addition to qualitative inspection of the simulated pressure and temperature fields. This study found that the computational model and the simulation parameters predicted an average of 24 ± 13% lower focal temperature elevations than observed in the treatments. The size of the simulated thermal focus was found to be 40 ± 13% smaller in the anterior-posterior direction and 22 ± 14% smaller in the inferior-superior direction than in the treatments. The location of the simulated thermal focus was off from the prescribed target by 0.3 ± 0.1 mm, while the peak focal temperature elevation observed in the measurements was off by 1.6 ± 0.6 mm. Although the results of the simulations suggest that there could be some inaccuracies in either the tissue parameters used, or in the simulation methods, the simulations were able to predict the focal spot locations and temperature elevations adequately for initial treatment planning performed to assess, for example, the feasibility of sonication. The accuracy of the simulations could be improved if more precise ultrasound tissue properties (especially of the skull bone) could be obtained.
M'Zali, Fatima; Bounizra, Carole; Leroy, Sandrine; Mekki, Yahia; Quentin-Noury, Claudine; Kann, Michael
2014-01-01
Aim of the Study In many countries, Low Level Disinfection (LLD) of covered transvaginal ultrasound probes is recommended between patients' examinations. The aim of this study was to evaluate the antimicrobial efficacy of LLD under routine conditions on a range of microorganisms. Materials and Methods Samples were taken over a six month period in a private French Radiology Center. 300 specimens derived from endovaginal ultrasound probes were analyzed after disinfection of the probe with wipes impregnated with a quaternary ammonium compound and chlorhexidine. Human papillomavirus (HPV) was sought in the first set of s100 samples, Chlamydia trachomatis and mycoplasmas were searched in the second set of 100 samples, bacteria and fungi in the third 100 set samples. HPV, C. trachomatis and mycoplasmas were detected by PCR amplification. PCR positive samples were subjected to a nuclease treatment before an additional PCR assay to assess the likely viable microorganisms. Bacteria and fungi were investigated by conventional methods. Results A substantial persistence of microorganisms was observed on the disinfected probes: HPV DNA was found on 13% of the samples and 7% in nuclease-resistant form. C. trachomatis DNA was detected on 20% of the probes by primary PCR but only 2% after nuclease treatment, while mycoplasma DNA was amplified in 8% and 4%, respectively. Commensal and/or environmental bacterial flora was present on 86% of the probes, occasionally in mixed culture, and at various levels (10->3000 CFU/probe); Staphylococcus aureus was cultured from 4% of the probes (10-560 CFU/probe). No fungi were isolated. Conclusion Our findings raise concerns about the efficacy of impregnated towels as a sole mean for disinfection of ultrasound probes. Although the ultrasound probes are used with disposable covers, our results highlight the potential risk of cross contamination between patients during ultrasound examination and emphasize the need for reviewing the disinfection procedure. PMID:24695371
Iordache, Sevastiţa; Filip, Maria-Monalisa; Georgescu, Claudia-Valentina; Angelescu, Cristina; Ciurea, Tudorel; Săftoiu, Adrian
2012-06-01
Besides representing angiogenesis markers, microvascular density (MVD) and vascular endothelial growth factor (VEGF) are two important tools for the assessment of prognosis in patients with gastric cancer. The aim of our study was to assess the Doppler parameters (resistivity and pulsatility indexes) and vascularity index (VI) calculated by contrast-enhanced power Doppler endoscopic ultrasound (CEPD-EUS) in correlation with the expression of intra-tumoral MVD and VEGF in patients with gastric cancer. The study included 20 consecutive patients with advanced gastric carcinoma, but without distant metastasis at initial assessment. All the patients were assessed by contrast-enhanced power Doppler endoscopic ultrasound (EUS) combined with pulsed Doppler examinations in the late venous phase. The vascularity index (VI) was calculated before and after injection of second generation microbubble contrast specific agent (SonoVue 2.4 mL), used as a Doppler signal enhancer. Moreover, pulsed Doppler parameters (resistivity and pulsatility indexes) were further calculated. The correlation between power Doppler parameters and pathological/molecular parameters (MVD assessed through immunohistochemistry with CD31 and CD34, as well as VEGF assessed through real-time PCR) was assessed. Kaplan-Meier survival analysis was used for the assessment of prognosis. Significantly statistical correlations were found between post-contrast VI and CD34 (p=0.0226), VEGF (p=0.0231), VEGF-A (p=0.0464) and VEGF-B (p=0.0022) while pre-contrast VI was correlated only with CD34 expression. Pulsatility index and resistivity index were not correlated with MVD or VEGF expression. Survival analysis demonstrated that VEGF-A is an accurate parameter for survival rate (p=0.045), as compared to VEGF (p=0.085) and VEGF-B (p=0.230). We did not find any correlation between the survival rate and ultrasound parameters (RI, PI, pre-contrast VI or post-contrast VI). Assessment of tumor vascularity using contrast-enhanced EUS, including analysis of spectral Doppler parameters is possible and feasible in gastric cancer patients. A correlation between measured EUS vascularity and pathological parameters of angiogenesis (MVD and VEGF expression) was found.
"US-detonated nano bombs" facilitate targeting treatment of resistant breast cancer.
Shi, Jinjin; Liu, Wei; Fu, Yu; Yin, Na; Zhang, Hongling; Chang, Junbiao; Zhang, Zhenzhong
2018-03-28
Reversal of drug resistance and targeted therapy are the keys but remain challenging in resistant breast cancer treatment. Herein, low frequency ultrasound detonated "nano bombs" were rationally designed and used for treatment of resistant breast cancer. For the 'nano bombs', the ammunition (Doxorubicin, DOX) was loaded into the ammunition depot (hollow mesoporous TiO 2 , MTNs), and the safety device (dsDNA) was wrapped on the surface of MTNs to avoid the unexpected DOX release. We found the "US-detonated explosive" abilities of "nano bomb" MTNs (NBMTNs), including explosive generation of ROS, explosive release of DOX, US-triggered lysosome escape and mitochondrial targeting in the in vitro and in vivo studies. More importantly, the drug resistance of MCF-7/ADR cells could be reversed via the inhibition of mitochondrial energy supply approach caused by the "explosion" of NBMTNs. Furthermore, NBMTNs combined the superior chemotherapy efficacy of DOX and potent SDT efficacy in one single platform and significantly enhanced the anticancer efficacy. Our results demonstrate an approach for reversing resistance and specific targeting of tumors using 'US-detonated nano bombs'. Copyright © 2018 Elsevier B.V. All rights reserved.
Ultrasound pretreatment of filamentous algal biomass for enhanced biogas production.
Lee, Kwanyong; Chantrasakdakul, Phrompol; Kim, Daegi; Kong, Mingeun; Park, Ki Young
2014-06-01
The filamentous alga Hydrodictyon reticulatum harvested from a bench-scale wastewater treatment pond was used to evaluate biogas production after ultrasound pretreatment. The effects of ultrasound pretreatment at a range of 10-5000 J/mL were tested with harvested H. reticulatum. Cell disruption by ultrasound was successful and showed a higher degree of disintegration at a higher applied energy. The range of 10-5000 J/mL ultrasound was able to disintegrated H. reticulatum and the soluble COD was increased from 250 mg/L to 1000 mg/L at 2500 J/mL. The disintegrated algal biomass was digested for biogas production in batch experiments. Both cumulative gas generation and volatile solids reduction data were obtained during the digestion. Cell disintegration due to ultrasound pretreatment increased the specific biogas production and degradation rates. Using the ultrasound approach, the specific methane production at a dose of 40 J/mL increased up to 384 mL/g-VS fed that was 2.3 times higher than the untreated sample. For disintegrated samples, the volatile solids reduction was greater with increased energy input, and the degradation increased slightly to 67% at a dose of 50 J/mL. The results also indicate that disintegration of the algal cells is the essential step for efficient anaerobic digestion of algal biomass. Copyright © 2013 Elsevier Ltd. All rights reserved.
Radziemski, Leon; Makin, Inder Raj S.
2015-01-01
Animal studies are an important step in proving the utility and safety of an ultrasound based implanted battery recharging system. To this end an Ultrasound Electrical Recharging System (USER™) was developed and tested. Experiments in vitro demonstrated power deliveries at the battery of up to 600 mW through 10 – 15 mm of tissue, 50 mW of power available at tissue depths of up to 50 mm, and the feasibility of using transducers bonded to titanium as used in medical implants. Acute in vivo studies in a porcine model were used to test reliability of power delivery, temperature excursions, and cooling techniques. The culminating five-week survival study involved repeated battery charging, a total of 10.5 hours of ultrasound exposure of the intervening living tissue, with an average RF input to electrical charging efficiency of 20%. This study was potentially the first long term cumulative living-tissue exposure using transcutaneous ultrasound power transmission to an implanted receiver in situ. Histology of the exposed tissue showed changes attributable primarily due to surgical implantation of the prototype device, and no damage due to the ultrasound exposure. The in vivo results are indicative of the potential safe delivery of ultrasound energy for a defined set of source conditions for charging batteries within implants. PMID:26243566
NASA Astrophysics Data System (ADS)
Matsukawa, S.; Makino, T.; Mori, S.; Koyama, D.; Takayanagi, S.; Mizuno, K.; Yanagitani, T.; Matsukawa, M.
2017-04-01
The bone fracture healing mechanism of the low-intensity pulsed ultrasound technique is not yet clearly understood. In our previous study, the electrical potentials induced in bone were successfully measured by focusing on piezoelectricity in the MHz range. Bone is composed of collagen and hydroxyapatite and has strong anisotropy. The purpose of this study is to investigate the effects of bone anisotropy on the electrical potentials induced by ultrasound irradiation. For this study, ultrasound bone transducers were fabricated using cortical bovine bone plates as piezoelectric devices. An ultrasound of 7.4 kPapeak-peak (i.e., the peak-to-peak pressure value) was used to irradiate the side surface of each bone plate. Electrical potentials induced in the bone plate were then measured by varying the wave propagation direction in the plate. The peak-to-peak values of these ultrasonically induced electrical potentials were found to vary with changes in the ultrasound propagation direction in the bone sample. The potential was maximized at an inclination of approximately 45° to the bone axis but was minimized around the three orthogonal directions. These maxima and minima ranged from 28 to 33 μVpeak-peak and from 5 to 12 μVpeak-peak, respectively. Additionally, our ultrasound results indicated a change in polarity due to bone anisotropy in the MHz range.
Radziemski, Leon; Makin, Inder Raj S
2016-01-01
Animal studies are an important step in proving the utility and safety of an ultrasound based implanted battery recharging system. To this end an Ultrasound Electrical Recharging System (USER™) was developed and tested. Experiments in vitro demonstrated power deliveries at the battery of up to 600 mW through 10-15 mm of tissue, 50 mW of power available at tissue depths of up to 50 mm, and the feasibility of using transducers bonded to titanium as used in medical implants. Acute in vivo studies in a porcine model were used to test reliability of power delivery, temperature excursions, and cooling techniques. The culminating five-week survival study involved repeated battery charging, a total of 10.5h of ultrasound exposure of the intervening living tissue, with an average RF input to electrical charging efficiency of 20%. This study was potentially the first long term cumulative living-tissue exposure using transcutaneous ultrasound power transmission to an implanted receiver in situ. Histology of the exposed tissue showed changes attributable primarily due to surgical implantation of the prototype device, and no damage due to the ultrasound exposure. The in vivo results are indicative of the potential safe delivery of ultrasound energy for a defined set of source conditions for charging batteries within implants. Copyright © 2015 Elsevier B.V. All rights reserved.
Usefulness of emergency ultrasound in nontraumatic cardiac arrest.
Volpicelli, Giovanni
2011-02-01
Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.
Xiao, Li-Hong; Chen, Pei-Ran; Gou, Zhong-Ping; Li, Yong-Zhong; Li, Mei; Xiang, Liang-Cheng; Feng, Ping
2017-01-01
The aim of this study is to evaluate the ability of the random forest algorithm that combines data on transrectal ultrasound findings, age, and serum levels of prostate-specific antigen to predict prostate carcinoma. Clinico-demographic data were analyzed for 941 patients with prostate diseases treated at our hospital, including age, serum prostate-specific antigen levels, transrectal ultrasound findings, and pathology diagnosis based on ultrasound-guided needle biopsy of the prostate. These data were compared between patients with and without prostate cancer using the Chi-square test, and then entered into the random forest model to predict diagnosis. Patients with and without prostate cancer differed significantly in age and serum prostate-specific antigen levels (P < 0.001), as well as in all transrectal ultrasound characteristics (P < 0.05) except uneven echo (P = 0.609). The random forest model based on age, prostate-specific antigen and ultrasound predicted prostate cancer with an accuracy of 83.10%, sensitivity of 65.64%, and specificity of 93.83%. Positive predictive value was 86.72%, and negative predictive value was 81.64%. By integrating age, prostate-specific antigen levels and transrectal ultrasound findings, the random forest algorithm shows better diagnostic performance for prostate cancer than either diagnostic indicator on its own. This algorithm may help improve diagnosis of the disease by identifying patients at high risk for biopsy.
Heated Ultrasound Gel and Patient Satisfaction with Bedside Ultrasound Studies: The HUGS Trial
Krainin, Benjamin M.; Thaut, Lane C.; April, Michael D.; Curtis, Ryan A.; Kaelin, Andrea L.; Hardy, Garrett B.; Weymouth, Wells L.; Srichandra, Jonathan; Chin, Eric J.; Summers, Shane M.
2017-01-01
Introduction Our goal was to determine if heated gel for emergency department (ED) bedside ultrasonography improves patient satisfaction compared to room-temperature gel. Methods We randomized a convenience sample of ED patients determined by their treating physician to require a bedside ultrasound (US) study to either heated gel (102.0° F) or room-temperature gel (82.3° F). Investigators performed all US examinations. We informed all subjects that the study entailed investigation into various measures to improve patient satisfaction with ED US examinations but did not inform them of our specific focus on gel temperature. Investigators wore heat-resistant gloves while performing the examinations to blind themselves to the gel temperature. After completion of the US, subjects completed a survey including the primary outcome measure of patient satisfaction as measured on a 100-mm visual analogue scale (VAS). A secondary outcome was patient perceptions of sonographer professionalism measured by an ordinal scale (1–5). Results We enrolled 124 subjects; 120 completed all outcome measures. Of these, 59 underwent randomization to US studies with room-temperature gel and 61 underwent randomization to heated US gel. Patient 100-mm VAS satisfaction scores were 83.9 among patients undergoing studies with room-temperature gel versus 87.6 among subjects undergoing studies with heated gel (effect size 3.7, 95% confidence interval −1.3–8.6). There were similarly no differences between the two arms with regard to patient perceptions of sonographer professionalism. Conclusion The use of heated ultrasound gel appears to have no material impact on the satisfaction of ED patients undergoing bedside ultrasound studies. PMID:29085538
O'Dochartaigh, Domhnall; Douma, Matthew; MacKenzie, Mark
2017-01-01
To describe the use of prehospital ultrasonography (PHUS) to support interventions, when used by physician and non-physician air medical crew (AMC), in a Canadian helicopter emergency medical service (HEMS). A retrospective review was conducted of consecutive patients who underwent ultrasound examination during HEMS care from January 1, 2009 through March 10, 2014. An a priori created data form was used to record patient demographics, type of ultrasound scan performed, ultrasound findings, location of scan, type of interventions supported by PHUS, factors that affected PHUS completion, and quality indicator(s). Data analysis was performed through descriptive statistics, Student's t-test for continuous variables, Z-test for proportions, and Mann-Whitney U Test for nonparametric data. Outcomes included interventions supported by PHUS, factors associated with incomplete scans, and quality indicators associated with PHUS use. Differences between physician and AMC groups were also assessed. PHUS was used in 455 missions, 318 by AMC and 137 by physicians. In combined trauma and medical patients, in the AMC group interventions were supported by PHUS in 26% of cases (95% CI 18-34). For transport physicians the percentage support was found to be significantly greater at 45% of cases (95% CI 34-56) p = < 0.006. Incomplete PHUS scans were common and reasons included patient obesity, lack of time, patient access, and clinical reasons. Quality indicators associated with PHUS were rarely identified. The use of PHUS by both physicians and non-physicians was found to support interventions in select trauma and medical patients. Key words: emergency medical services; aircraft; helicopter; air ambulance; ultrasonography; emergency care, prehospital; prehospital emergency care.
Objective assessment of operator performance during ultrasound-guided procedures.
Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R
2011-09-01
Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.
Alonso-Quintela, Paula; Oulego-Erroz, Ignacio; Rodriguez-Blanco, Silvia; Muñiz-Fontan, Manoel; Lapeña-López-de Armentia, Santiago; Rodriguez-Nuñez, Antonio
2015-11-01
To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. Prospective observational study. PICU of a university hospital. Patients aged 0-14 who required a central venous catheter. None. Central venous catheter tip location was confirmed by ultrasound and chest radiography. Central venous catheters were classified as intra-atrial or extra-atrial according to their positions in relation to the cavoatrial junction. Central venous catheters located outside the vena cava were considered malpositioned. The distance between the catheter tip and the cavoatrial junction was measured. The time elapsed from image capture to interpretation was recorded. Fifty-one central venous catheters in 40 patients were analyzed. Chest radiography and ultrasound results agreed 94% of the time (κ coefficient, 0.638; p < 0.001) in determining intra-atrial and extra-atrial locations and 92% of the time in determining the diagnosis of central venous catheter malposition (κ coefficient, 0.670; p < 0.001). Chest radiography indicated a greater distance between the central venous catheter tip and the cavoatrial junction than measured by ultrasound, with a mean difference of 0.38 cm (95% CI, +0.27, +0.48 cm). Three central venous catheters were classified as extra-atrial by chest radiography but as intra-atrial by ultrasound. To locate the central venous catheter tip, ultrasound required less time than chest radiography (22.96 min [20.43 min] vs 2.23 min [1.06 min]; p < 0.001). Bedside ultrasound showed a good agreement with chest radiography in detecting central venous catheter tip location and revealing incorrect positions. Ultrasound could be a preferable method for routine verification of central venous catheter tip and can contribute to increased patient safety.
Sheng, Qingsong; Ma, Ning; Huang, Huijuan; Xu, Bo; He, Chunni; Song, Yanfeng
2015-01-01
Recently, increasing evidence has shown that uterus preservation is beneficial for pelvic organ prolapse (POP) patients, both physiologically and psychologically. However, the preoperative indicators for uterus preservation have rarely been examined. The current study was designed to determine the relationship between the preoperative evaluated uterus weight and the operation selection (preserving the uterus or not) in pelvic reconstructive surgery (PRS) using vaginal meshes. First, in a series of 96 patients undergoing hysterectomy, the uterine weight was calculated by preoperative ultrasound measurements, and was then compared with the postoperative actual weight of the uterus. Subsequently, in a series of 65 patients undergone PRS using vaginal meshes and preserving the uterus, the uterine weight was calculated by preoperative ultrasound measurements. Lastly, in a series of 43 patients with a uterine weight > 56.12 g who had undergone PRS using vaginal meshes, the operation success rate in patients with a preserved uterus was compared to patients for whom the uterus was not preserved. The results showed that uterus weight can be evaluated by ultrasound and used as a preoperative indicator for whether the uterus should be preserved or not in PRS when using vaginal meshes. It was indicated that preoperative evaluation of uterine weight is beneficial for surgical planning and guidance. PMID:25755793
El-Kannishy, Ghada; Kamal, Shaheer; Mousa, Amany; Saleh, Omayma; Badrawy, Adel El; Farahaty, Reham El; Shokeir, Tarek
2010-01-01
Evidence regarding endothelial function in both obese and nonobese women with PCOS is contradictory. It is unknown whether obese women with PCOS carry an increased risk related to body mass index (BMI). To identify endothelial function and investigate its relationship to body mass index and insulin resistance in young women with PCOS. Twenty-two obese women with PCOS (BMI 35.2 ± 3.2) as well as fourteen lean women (BMI 22.8 ± 2.1)with PCOS were included in the study. Fasting serum insulin, blood glucose were estimated and HOMA and Quicki index were calculated. All patients were subjected to ultrasound recording of brachial artery diameter at rest and after reactive hyperemia (FMD) for assessment of endothelial function. Ten age matched healthy females with normal BMI were chosen as a control group. There were higher basal insulin levels with lower Quicki index and higher HOMA index in women with PCOS than normal group, but the differences were significant only between obese PCOS subgroup and control. On the other hand, FMD was significantly and equally decreased in both groups of women with PCOS, compared with control subjects (3.7 ± 3.2% in the nonobese subgroup and 3.5 ± 2.8% in the obese one vs. 10.6 ± 4.1% in control subjects, P, 0.001). FMD was not correlated with BMI nor insulin resistance indices. Endothelial dysfunction is already present in young women with PCOS. In this patient group, it cannot be attributed to insulin resistance or obesity. © 2010 Asian Oceanian Association for the Study of Obesity . Published by Elsevier Ltd. All rights reserved.
Edvardsson, Kristina; Graner, Sophie; Thi, Lan Pham; Åhman, Annika; Small, Rhonda; Lalos, Ann; Mogren, Ingrid
2015-01-01
Objective To explore Vietnamese obstetricians’ experiences and views on the role of obstetric ultrasound in clinical management of complicated pregnancy and in situations where maternal and fetal health interests conflict. Design Seventeen obstetricians in northern Vietnam were interviewed as part of the CROss-Country Ultrasound Study (CROCUS) project in 2013. Data were analysed using qualitative content analysis. Results The participants described ultrasound as a central tool in prenatal care, although they called for increased training and resources to prevent inappropriate management. A prevailing overuse driven by women's request and increased commercialisation was described. Other clinical examinations were seen as being disregarded by women in favour of ultrasound, resulting in missed opportunities for identifying potential pregnancy complications. The use of ultrasound for sex selection purposes raised concern among participants. Visualisation of human features or heartbeat during ultrasound was commonly described as the point where the fetus became regarded as a ‘person’. Women were said to prioritise fetal health interests over their own health, particularly if a woman had difficulties becoming pregnant or had undergone assisted fertilisation. The woman's husband and his family were described as having an important role in decision-making in situations of maternal and fetal health conflicts. Conclusions This study provides insight into issues surrounding ultrasound use in contemporary Vietnam, some of which may be specific to this low-income context. It is clear that ultrasound has become a central tool in prenatal care in Vietnam and that it has also been embraced by women. However, there seems to be a need to balance women's demands for obstetric ultrasound with better recognition of the valuable contribution to be made by the full range of clinical examinations in pregnancy, along with a more strategic allocation of resources, that is, use of obstetric ultrasound based on clinical indications. Better regulation of private obstetric practice also appears to be needed. While the root causes of sex selection need to be addressed at societal level, efforts are also required more immediately to find ways to combat the inappropriate use of ultrasound for the purpose of sex selection. PMID:26519131
Preptin in women with polycystic ovary syndrome.
Mierzwicka, Agata; Kuliczkowska-Plaksej, Justyna; Kolačkov, Katarzyna; Bolanowski, Marek
2018-06-01
Polycystic ovary syndrome (PCOS) patients, frequently develop metabolic complications, such as insulin resistance (IR), impaired carbohydrate metabolism, dyslipidemia, obesity. Among the new markers responsible for metabolic disorders, preptin seems to be of great significance. One hundred and thirty-four women aged 17-45 were enrolled. PCOS was diagnosed in 73 women on the basis of ESHRE-ASRM criteria. Non-PCOS group consisted of 61 women with regular menstruation matched for nutritional status. All women underwent anamnesis, physical examination, anthropometric measurements, the abdominal ultrasound examination, and dual energy X-ray absorptiometry (DXA). Serum adropin levels were determined by ELISA. Biochemical and hormonal (testosterone, androstenedione, LH, FSH, estradiol) measurements were also performed. Insulin resistance indices (HOMA, QUICKI, Matsuda) and free androgen index (FAI) were calculated with the test results according to the standard formula. For all comparisons, statistical significance was defined by p ≤ .05. Serum preptin levels were significantly higher in the PCOS group. No significant correlations between preptin level and metabolic and hormonal markers were observed. The logistic regression analysis demonstrated that serum preptin level was an independent factor differentiating the two groups. Serum preptin levels were significantly higher in women with PCOS compared with controls. This peptide might be an independent predictor of PCOS in the future.
Ultrasound for assessing disease activity in IBD patients: a systematic review of activity scores.
Bots, S; Nylund, K; Löwenberg, M; Gecse, K; Gilja, O H; D'Haens, G
2018-04-19
Ultrasound (US) indices for assessing disease activity in IBD patients have never been critically reviewed. We aimed to systematically review the quality and reliability of available ultrasound (US) indices compared with reference standards for grading disease activity in IBD patients. Pubmed, Embase and Medline were searched from 1990 until June 2017. Relevant publications were identified through full text review after initial screening by 2 investigators. Data on methodology and index characteristics were collected. Study quality was assessed with a modified version of the Quadas-2 tool for risk of bias assessment. Of 20 studies with an US index, 11 studies met the inclusion criteria. Out of these 11 studies, 7 and 4 studied CD and UC activity indices, respectively. Parameters that were used in these indices included bowel wall thickness (BWT), Doppler signal (DS), wall layer stratification (WLS), compressibility, peristalsis, haustrations, fatty wrapping, contrast enhancement (CE) and strain pattern. Study quality was graded high in 5 studies, moderate in 3 studies and low in 3 studies. Ileocolonoscopy was used as the reference standard in 9 studies. In 1 study a combined index of ileocolonoscopy and barium contrast radiography and in 1 study histology was used as the reference standard. Only 5 studies used an established endoscopic index for comparison with US. Several US indices for assessing disease activity in IBD are available; however the methodology for development was suboptimal in most studies. For the development of future indices stringent methodological design is required.
Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel
2015-09-01
OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.
Ultrasound-assisted extraction of hemicellulose and phenolic compounds from bamboo bast fiber powder
Su, Jing; Vielnascher, Robert; Silva, Carla; Cavaco-Paulo, Artur; Guebitz, Georg M.
2018-01-01
Ultrasound-assisted extraction of hemicellulose and phenolic compounds from bamboo bast fibre powder was investigated. The effect of ultrasonic probe depth and power input parameters on the type and amount of products extracted was assessed. The results of input energy and radical formation correlated with the calculated values for the anti-nodal point (λ/4; 16.85 mm, maximum amplitude) of the ultrasonic wave in aqueous medium. Ultrasonic treatment at optimum probe depth of 15 mm improve 2.6-fold the extraction efficiencies of hemicellulose and phenolic lignin compounds from bamboo bast fibre powder. LC-Ms-Tof (liquid chromatography-mass spectrometry-time of flight) analysis indicated that ultrasound led to the extraction of coniferyl alcohol, sinapyl alcohol, vanillic acid, cellobiose, in contrast to boiling water extraction only. At optimized conditions, ultrasound caused the formation of radicals confirmed by the presence of (+)-pinoresinol which resulted from the radical coupling of coniferyl alcohol. Ultrasounds revealed to be an efficient methodology for the extraction of hemicellulosic and phenolic compounds from woody bamboo without the addition of harmful solvents. PMID:29856764
Thermosonication as a potential quality enhancement technique of apple juice.
Abid, Muhammad; Jabbar, Saqib; Hu, Bing; Hashim, Malik Muhammad; Wu, Tao; Lei, Shicheng; Khan, Muhammad Ammar; Zeng, Xiaoxiong
2014-05-01
Enzymatic browning and microbial growth lead to quality losses in apple products. In the present study, fresh apple juice was thermosonicated using ultrasound in-bath (25 kHz, 30 min, 0.06 W cm(-3)) and ultrasound with-probe sonicator (20 kHz, 5 and 10 min, 0.30 W cm(-3)) at 20, 40 and 60°C for inactivation of enzymes (polyphenolase, peroxidase and pectinmethylesterase) and microflora (total plate count, yeast and mold). Additionally, ascorbic acid, total phenolics, flavonoids, flavonols, pH, titratable acidity, (°)Brix and color values influenced by thermosonication were investigated. The highest inactivation of enzymes was obtained in ultrasound with-probe at 60°C for 10 min, and the microbial population was completely inactivated at 60°C. The retention of ascorbic acid, total phenolics, flavonoids and flavonols were significantly higher in ultrasound with-probe than ultrasound in-bath at 60°C. These results indicated the usefulness of thermosonication for apple juice processing at low temperature, for enhanced inactivation of enzymes and microorganisms. Copyright © 2013 Elsevier B.V. All rights reserved.
Kerasnoudis, A; Pitarokoili, K; Gold, R; Yoon, M-S
2015-01-15
The aim of this observational study was to evaluate the applicability of a recently introduced ultrasound score (Bochum ultrasound score; BUS) in distinguishing the chronic inflammatory demyelinating polyneuropathy (CIDP) from the multifocal motor neuropathy (MMN) or the multifocal acquired demyelinating sensory and motor neuropathy (MADSAM). The BUS underwent prospective evaluation of its applicability in a group of 13 patients (mean age 47.2, SD ± 13.7, 9 women), who were referred to our department between January 2012 and August 2013 with the clinical picture of a chronic symmetrical or asymmetrical sensory/sensorimotor neuropathy. The cut-off value of ≥ 2 points in the "Bochum ultrasound score" showed a sensitivity of 80% and specificity of 87.5% (PPV=80%, NPV=87.5%) in distinguishing CIDP from MMN or MADSAM. The BUS seems to allow a reliable distinction of CIDP from multifocal acquired demyelinating polyneuropathies causing predominantly motor nerve dysfunction, such as MMN or MADSAM. Our ultrasound findings indicate a stronger relationship of MADSAM to MMN, than to CIDP. Copyright © 2014 Elsevier B.V. All rights reserved.
Pawar, Shweta V; Rathod, Virendra K
2018-07-01
Low energy ultrasound irradiation was used to enhance co-production of enzymes uricase and alkaline protease using Bacillus licheniformis NRRL 14209. Production of uricase and alkaline protease was evaluated for different ultrasound parameters such as ultrasound power, time of irradiation, duty cycle and growth stage of organisms at which irradiation is carried out. Maximum uricase production of 0.825 U/mL and alkaline protease of 0.646 U/mL have been obtained when fermentation broth was irradiated at 6 h of growth stage with 60 W power for 15 min of duration having 40% of duty cycle. The enzyme yield was found to be enhanced by a factor of 1.9-3.8 and 1.2-2.2 for uricase and alkaline protease respectively. Nevertheless, intracellular uricase was also observed in a fermentation broth after ultrasonic process intensification. The results indicate the effectiveness of low frequency ultrasound in improving enzyme yields with a vision of commercial applicability of the process. Copyright © 2018 Elsevier B.V. All rights reserved.
Da Porto, C; Natolino, A; Decorti, D
2015-03-01
Ultrasound pre-treatment of intact hemp seeds without any solvent assistance was carried out for 10, 20 and 40 min prior to SCCO2 extraction at 40 °C, 300 bar and 45 kg CO2/kg feed. Sonication time effect on SC-CO2 extraction was investigated by the extraction kinetics. The maximum extraction yield was estimated to be 24.03 (% w/w) after 10 min of ultrasonic pre-treatment. The fatty acid compositions of the oils extracted by SC-CO2 without and with ultrasound pre-treatments was analyzed using gas chromatography. It was shown that the content of linoleic, α-linolenic and oleic acids (the most abundant unsaturated fatty acids) of the hemp seed oils were not affected significantly by the application of ultrasound. UV spectroscopy indices (K232 and K268) and antiradical capacity were used to follow the quality of oils. Significant were the changes in their antiradical capacity due to ultrasound treatment. A comparison with the oil extracted by Soxhlet was also given.
Microstructural and techno-functional properties of cassava starch modified by ultrasound.
Monroy, Yuliana; Rivero, Sandra; García, María A
2018-04-01
This work was focused on the correlation between the structural and techno-functional properties of ultrasound treated cassava starch for the preparation of tailor-made starch-based ingredients and derivatives. Furthermore, the effect of treatment time, sample conditioning and ultrasound amplitude was studied. Ultrasonic treatment of cassava starch induced structural disorganization and microstructural changes evidenced mainly in the morphological characteristics of the granules and in their degrees of crystallinity. These structural modifications were supported by ATR-FTIR and SEM and CSLM studies as well as DRX and thermal analysis. The selection of the processing conditions is critical due to the complete gelatinization of the starch was produced with the maximum amplitude tested and without temperature control. Rheological dynamical analysis indicated changes at the molecular level in starch granules due to the ultrasound treated, revealing the paste stability under refrigeration condition. PCA allow to establish the interrelationships between microstructural and techno-functional properties. In summary, different starch derivatives could be obtained by adjusting the ultrasound treatment conditions depending on their potential applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Vafaeian, Behzad; Al-Daghreer, Saleh; El-Rich, Marwan; Adeeb, Samer; El-Bialy, Tarek
2015-08-01
The therapeutic effect of low-intensity pulsed ultrasound on orthodontically induced inflammatory root resorption is believed to be brought about through mechanical signals induced by the low-intensity pulsed ultrasound. However, the stimulatory mechanism triggering dental cell response has not been clearly identified yet. The aim of this study was to evaluate possible relations between the amounts of new cementum regeneration and ultrasonic parameters such as pressure amplitude and time-averaged energy density. We used the finite-element method to simulate the previously published experiment on ultrasonic wave propagation in the dentoalveolar structure of beagle dogs. Qualitative relations between the thickness of the regenerated cementum in the experiment and the ultrasonic parameters were observed. Our results indicated that the areas of the root surface with greater ultrasonic pressure were associated with larger amounts of cementum regeneration. However, the establishment of reliable quantitative correlations between ultrasound parameters and cementum regeneration requires more experimental data and simulations. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kobayashi, Masaki; Kikuchi, Naoto; Sato, Akihiro
2015-01-01
This letter proposes and demonstrates ultrasound-combined optical imaging in dense scattering media. A peroxyoxalate chemiluminescence system that includes fluorophores to chemically excite the pigment is stimulated by ultrasound irradiation with power of less than 0.14 W/cm2. Using focused ultrasound, the chemiluminescence is selectively spatially enhanced, which leads to imaging of the pigment when embedded in a light-scattering medium via scanning of the focal point. The ultrasonically enhanced intensity of the chemiluminescence depends on the base intensity of the chemiluminescence without the applied ultrasound irradiation, which thereby enables quantitative determination of the fluorophore concentration. The authors demonstrate the potential of this method to resolve chemiluminescent targets in a dense scattering medium that is comparable to biological tissue. An image was acquired of a chemiluminescent target that included indocyanine green as the fluorophore embedded at a depth of 20 mm in an Intralipid-10% 200 ml/l solution scattering medium (the reduced scattering coefficient was estimated to be approximately 1.3 mm-1), indicating the potential for expansion of this technique for use in biological applications.
Passive cavitation imaging with ultrasound arrays
Salgaonkar, Vasant A.; Datta, Saurabh; Holland, Christy K.; Mast, T. Douglas
2009-01-01
A method is presented for passive imaging of cavitational acoustic emissions using an ultrasound array, with potential application in real-time monitoring of ultrasound ablation. To create such images, microbubble emissions were passively sensed by an imaging array and dynamically focused at multiple depths. In this paper, an analytic expression for a passive image is obtained by solving the Rayleigh–Sommerfield integral, under the Fresnel approximation, and passive images were simulated. A 192-element array was used to create passive images, in real time, from 520-kHz ultrasound scattered by a 1-mm steel wire. Azimuthal positions of this target were accurately estimated from the passive images. Next, stable and inertial cavitation was passively imaged in saline solution sonicated at 520 kHz. Bubble clusters formed in the saline samples were consistently located on both passive images and B-scans. Passive images were also created using broadband emissions from bovine liver sonicated at 2.2 MHz. Agreement was found between the images and source beam shape, indicating an ability to map therapeutic ultrasound beams in situ. The relation between these broadband emissions, sonication amplitude, and exposure conditions are discussed. PMID:20000921
Passive cavitation imaging with ultrasound arrays.
Salgaonkar, Vasant A; Datta, Saurabh; Holland, Christy K; Mast, T Douglas
2009-12-01
A method is presented for passive imaging of cavitational acoustic emissions using an ultrasound array, with potential application in real-time monitoring of ultrasound ablation. To create such images, microbubble emissions were passively sensed by an imaging array and dynamically focused at multiple depths. In this paper, an analytic expression for a passive image is obtained by solving the Rayleigh-Sommerfield integral, under the Fresnel approximation, and passive images were simulated. A 192-element array was used to create passive images, in real time, from 520-kHz ultrasound scattered by a 1-mm steel wire. Azimuthal positions of this target were accurately estimated from the passive images. Next, stable and inertial cavitation was passively imaged in saline solution sonicated at 520 kHz. Bubble clusters formed in the saline samples were consistently located on both passive images and B-scans. Passive images were also created using broadband emissions from bovine liver sonicated at 2.2 MHz. Agreement was found between the images and source beam shape, indicating an ability to map therapeutic ultrasound beams in situ. The relation between these broadband emissions, sonication amplitude, and exposure conditions are discussed.
Chemat, Smain; Aissa, Abdallah; Boumechhour, Abdenour; Arous, Omar; Ait-Amar, Hamid
2017-01-01
This study proposes an ultrasound-horn system for the extraction of a natural active compound "artemisinin" from Artemisia annua L. leaves as an alternative to hot maceration technique. Ultrasound leaching improves artemisinin recovery at all temperatures where only ten minutes is required to recover 70% (4.42mgg -1 ) compared to 60min of conventional hot leaching for the same yield. For instance, ultrasound treatment at 30°C produced a higher yield than the one obtained by conventional maceration at 40°C. Kinetic study suggests that the extraction pattern can be assimilated, during the first ten minutes, to a first order steady state, from which activation energy calculations revealed that each gram of artemisinin required 7.38kJ in ultrasound versus 10.3kJ in the conventional system. Modeling results indicate the presence of two extraction stages, a faster stage with a diffusion coefficient of 19×10 -5 cm 2 min -1 for ultrasound technique at 40°C, seven times higher than the conventional one; and a second deceleration stage similar for both techniques with diffusion coefficient ranging from 1.7 to 3.1×10 -5 cm 2 min -1 . It is noted that the efficient ultrasound extraction potential implies extraction of higher amount of co-metabolites so low artemisinin crystal purity is engendered but a combination with a purification step using activated charcoal and celite adsorbents produced crystals with comparable purity for conventional and ultrasound samples. Copyright © 2016 Elsevier B.V. All rights reserved.
On the reproducibility of expert-operated and robotic ultrasound acquisitions.
Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir
2017-06-01
We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.
Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H
2006-12-01
To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (p<0.01) and 0.328 (p<0.05), respectively. The ultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.
Feasibility of a focused ultrasound training programme for medical undergraduate students.
Wong, Ivan; Jayatilleke, Thilina; Kendall, Richard; Atkinson, Paul
2011-03-01
Although ultrasound is a core skill for many clinical specialties, UK medical schools are not currently required to teach this skill. The College of Emergency Medicine (CEM) has championed the use of ultrasound to answer focused clinical questions in emergency settings. We have designed and piloted an ultrasound training course for undergraduate medical students addressing one important indication: ultrasound assessment of the abdominal aorta. Fourteen clinical students, who had no prior experience of using ultrasound, received focused ultrasound training in the form of didactic instruction, a short bedside practical workshop and self-directed learning over a 20-day period. At the end of this period, the students were assessed by a structured viva and an observed structured clinical examination (OSCE) used for accreditation by the CEM. The primary endpoint was the number of students who passed the assessment. The secondary endpoint was the accuracy of the students' anatomical measurements. Thirteen of the 14 (93%) students completed the training and assessment. Eight of the 13 (62%) students passed both the viva and OSCE, and were deemed to have achieved the CEM standard. The measurements by the competent students were not statistically different from those of experienced practitioners. We have shown for the first time that it is feasible to train inexperienced undergraduate students to scan the abdominal aorta to a professional standard using a focused training course. It is time for the medical education community to address whether focused ultrasound training should accompany traditional clinical skills, such as using a stethoscope, in UK medical school curricula. © Blackwell Publishing Ltd 2011.
NASA Astrophysics Data System (ADS)
Zhang, Haichong K.; Huang, Howard; Lei, Chen; Kim, Younsu; Boctor, Emad M.
2017-03-01
Photoacoustic (PA) imaging has shown its potential for many clinical applications, but current research and usage of PA imaging are constrained by additional hardware costs to collect channel data, as the PA signals are incorrectly processed in existing clinical ultrasound systems. This problem arises from the fact that ultrasound systems beamform the PA signals as echoes from the ultrasound transducer instead of directly from illuminated sources. Consequently, conventional implementations of PA imaging rely on parallel channel acquisition from research platforms, which are not only slow and expensive, but are also mostly not approved by the FDA for clinical use. In previous studies, we have proposed the synthetic-aperture based photoacoustic re-beamformer (SPARE) that uses ultrasound beamformed radio frequency (RF) data as the input, which is readily available in clinical ultrasound scanners. The goal of this work is to implement the SPARE beamformer in a clinical ultrasound system, and to experimentally demonstrate its real-time visualization. Assuming a high pulsed repetition frequency (PRF) laser is used, a PZT-based pseudo PA source transmission was synchronized with the ultrasound line trigger. As a result, the frame-rate increases when limiting the image field-of-view (FOV), with 50 to 20 frames per second achieved for FOVs from 35 mm to 70 mm depth, respectively. Although in reality the maximum PRF of laser firing limits the PA image frame rate, this result indicates that the developed software is capable of displaying PA images with the maximum possible frame-rate for certain laser system without acquiring channel data.
Liu, Zheng; Gao, Shunji; Zhao, Yang; Li, Peijing; Liu, Jia; Li, Peng; Tan, Kaibin; Xie, Feng
2012-02-01
Tumor angiogenesis is of vital importance to the growth and metastasis of solid tumors. The angiogenesis is featured with a defective, leaky and fragile vascular construction. Microbubble enhanced ultrasound (MEUS) cavitation is capable of mechanical disruption of small blood vessels depending on effective acoustic pressure amplitude. We hypothesized that acoustic cavitation combining high-pressure amplitude pulsed ultrasound (US) and circulating microbubble could potentially disrupt tumor vasculature. A high-pressure amplitude, pulsed ultrasound device was developed to induce inertial cavitation of circulating microbubbles. The tumor vasculature of rat Walker 256 was insonated percutaneously with two acoustic pressures, 2.6 MPa and 4.8 MPa, both with intravenous injection of a lipid microbubble. The controls were treated by the ultrasound only or sham ultrasound exposure. Contrast enhanced ultrasound (CEUS) and histology were performed to assess tumor circulation and pathological changes. The CEUS results showed that the circulation of Walker 256 tumors could be completely blocked off for 24 hours in 4.8 MPa treated tumors. The CEUS gray scale value (GSV) indicated that there was significant GSV drop-off in both of the two experimental groups but none in the controls. Histology showed that the tumor microvasculature was disrupted into diffuse hematomas accompanied by thrombosis, intercellular edema and multiple cysts formation. The 24 hours of tumor circulation blockage resulted in massive necrosis of the tumor. MEUS provides a new, simple physical method for anti-angiogenic therapy and may have great potential for clinical applications. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Tadayyon, Hadi; Sannachi, Lakshmanan; Gangeh, Mehrdad J.; Kim, Christina; Ghandi, Sonal; Trudeau, Maureen; Pritchard, Kathleen; Tran, William T.; Slodkowska, Elzbieta; Sadeghi-Naini, Ali; Czarnota, Gregory J.
2017-01-01
Quantitative ultrasound (QUS) can probe tissue structure and analyze tumour characteristics. Using a 6-MHz ultrasound system, radiofrequency data were acquired from 56 locally advanced breast cancer patients prior to their neoadjuvant chemotherapy (NAC) and QUS texture features were computed from regions of interest in tumour cores and their margins as potential predictive and prognostic indicators. Breast tumour molecular features were also collected and used for analysis. A multiparametric QUS model was constructed, which demonstrated a response prediction accuracy of 88% and ability to predict patient 5-year survival rates (p = 0.01). QUS features demonstrated superior performance in comparison to molecular markers and the combination of QUS and molecular markers did not improve response prediction. This study demonstrates, for the first time, that non-invasive QUS features in the core and margin of breast tumours can indicate breast cancer response to neoadjuvant chemotherapy (NAC) and predict five-year recurrence-free survival. PMID:28401902
Tadayyon, Hadi; Sannachi, Lakshmanan; Gangeh, Mehrdad J; Kim, Christina; Ghandi, Sonal; Trudeau, Maureen; Pritchard, Kathleen; Tran, William T; Slodkowska, Elzbieta; Sadeghi-Naini, Ali; Czarnota, Gregory J
2017-04-12
Quantitative ultrasound (QUS) can probe tissue structure and analyze tumour characteristics. Using a 6-MHz ultrasound system, radiofrequency data were acquired from 56 locally advanced breast cancer patients prior to their neoadjuvant chemotherapy (NAC) and QUS texture features were computed from regions of interest in tumour cores and their margins as potential predictive and prognostic indicators. Breast tumour molecular features were also collected and used for analysis. A multiparametric QUS model was constructed, which demonstrated a response prediction accuracy of 88% and ability to predict patient 5-year survival rates (p = 0.01). QUS features demonstrated superior performance in comparison to molecular markers and the combination of QUS and molecular markers did not improve response prediction. This study demonstrates, for the first time, that non-invasive QUS features in the core and margin of breast tumours can indicate breast cancer response to neoadjuvant chemotherapy (NAC) and predict five-year recurrence-free survival.
Ultrasound Dopplerography of abdomen pathology using statistical computer programs
NASA Astrophysics Data System (ADS)
Dmitrieva, Irina V.; Arakelian, Sergei M.; Wapota, Alberto R. W.
1998-04-01
The modern ultrasound dopplerography give us the big possibilities in investigation of gemodynamical changes in all stages of abdomen pathology. Many of researches devoted to using of noninvasive methods in practical medicine. Now ultrasound Dopplerography is one of the basic one. We investigated 250 patients from 30 to 77 ages, including 149 men and 101 women. The basic diagnosis of all patients was the Ischaemic Pancreatitis. The Second diagnoses of pathology were the Ischaemic Disease of Heart, Gypertension, Atherosclerosis, Diabet, Vascular Disease of Extremities. We researched the abdominal aorta and her branches: Arteria Mesenterica Superior (AMS), truncus coeliacus (TC), arteria hepatica communis (AHC), arteria lienalis (AL). For investigation we use the following equipment: ACUSON 128 XP/10c, BIOMEDIC, GENERAL ELECTRIC (USA, Japan). We analyzed the following componetns of gemodynamical changes of abdominal vessels: index of pulsation, index of resistance, ratio of systol-dystol, speed of blood circulation. Statistical program included the following one: 'basic statistic's,' 'analytic program.' In conclusion we determined that the all gemodynamical components of abdominal vessels had considerable changes in abdominal ischaemia than in normal situation. Using the computer's program for definition degree of gemodynamical changes, we can recommend the individual plan of diagnostical and treatment program.
Measuring the acoustoelectric interaction constant using ultrasound current source density imaging
NASA Astrophysics Data System (ADS)
Li, Qian; Olafsson, Ragnar; Ingram, Pier; Wang, Zhaohui; Witte, Russell
2012-10-01
Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all materials; K directly affects the magnitude of the detected voltage signal in UCSDI. This paper describes a technique for measuring K in biological tissue, and reports its value for the first time in cadaver hearts. A custom chamber was designed and fabricated to control the geometry for estimating K, which was measured in different ionic salt solutions and seven cadaver rabbit hearts. We found K to be strongly dependent on concentration for the divalent salt CuSO4, but not for the monovalent salt NaCl, consistent with their different chemical properties. In the rabbit heart, K was determined to be 0.041±0.012%/MPa, similar to the measurement of K in physiological saline (0.034±0.003%/MPa). This study provides a baseline estimate of K for modeling and experimental studies that involve UCSDI to map cardiac conduction and reentry currents associated with arrhythmias.
Segmentation of breast ultrasound images based on active contours using neutrosophic theory.
Lotfollahi, Mahsa; Gity, Masoumeh; Ye, Jing Yong; Mahlooji Far, A
2018-04-01
Ultrasound imaging is an effective approach for diagnosing breast cancer, but it is highly operator-dependent. Recent advances in computer-aided diagnosis have suggested that it can assist physicians in diagnosis. Definition of the region of interest before computer analysis is still needed. Since manual outlining of the tumor contour is tedious and time-consuming for a physician, developing an automatic segmentation method is important for clinical application. The present paper represents a novel method to segment breast ultrasound images. It utilizes a combination of region-based active contour and neutrosophic theory to overcome the natural properties of ultrasound images including speckle noise and tissue-related textures. First, due to inherent speckle noise and low contrast of these images, we have utilized a non-local means filter and fuzzy logic method for denoising and image enhancement, respectively. This paper presents an improved weighted region-scalable active contour to segment breast ultrasound images using a new feature derived from neutrosophic theory. This method has been applied to 36 breast ultrasound images. It generates true-positive and false-positive results, and similarity of 95%, 6%, and 90%, respectively. The purposed method indicates clear advantages over other conventional methods of active contour segmentation, i.e., region-scalable fitting energy and weighted region-scalable fitting energy.
NASA Astrophysics Data System (ADS)
Gray, Robert H. R.; Leslie, Thomas A.; Civale, John; Kennedy, James E.; ter Haar, Gail
2007-05-01
Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.
Finnoff, Jonathan T; Hall, Mederic M; Adams, Erik; Berkoff, David; Concoff, Andrew L; Dexter, William; Smith, Jay
2015-02-01
The use of diagnostic and interventional ultrasound has significantly increased over the past decade. A majority of the increased utilisation is by non-radiologists. In sports medicine, ultrasound is often used to guide interventions such as aspirations, diagnostic or therapeutic injections, tenotomies, releases and hydrodissections. Critically review the literature related to the accuracy, efficacy and cost-effectiveness of ultrasound-guided injections (USGIs) in major, intermediate and small joints; and soft tissues. Systematic review of the literature. USGIs are more accurate than landmark-guided injections (LMGIs; strength of recommendation taxonomy (SORT) Evidence Rating=A). USGIs are more efficacious than LMGIs (SORT Evidence Rating=B). USGIs are more cost-effective than LMGIs (SORT Evidence Rating=B). Ultrasound guidance is required to perform many new procedures (SORT Evidence Rating=C). The findings of this position statement indicate there is strong evidence that USGIs are more accurate than LMGI, moderate evidence that they are more efficacious and preliminary evidence that they are more cost-effective. Furthermore, ultrasound-guided (USG) is required to perform many new, advanced procedures and will likely enable the development of innovative USG surgical techniques in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Kwok, Sheldon J J; El Kaffas, Ahmed; Lai, Priscilla; Al Mahrouki, Azza; Lee, Justin; Iradji, Sara; Tran, William Tyler; Giles, Anoja; Czarnota, Gregory J
2013-11-01
Tumor responses to high-dose (>8 Gy) radiation therapy are tightly connected to endothelial cell death. In the study described here, we investigated whether ultrasound-activated microbubbles can locally enhance tumor response to radiation treatments of 2 and 8 Gy by mechanically perturbing the endothelial lining of tumors. We evaluated vascular changes resulting from combined microbubble and radiation treatments using high-frequency 3-D power Doppler ultrasound in a breast cancer xenograft model. We compared treatment effects and monitored vasculature damage 3 hours, 24 hours and 7 days after treatment delivery. Mice treated with 2 Gy radiation and ultrasound-activated microbubbles exhibited a decrease in vascular index to 48 ± 10% at 24 hours, whereas vascular indices of mice treated with 2 Gy radiation alone or microbubbles alone were relatively unchanged at 95 ± 14% and 78 ± 14%, respectively. These results suggest that ultrasound-activated microbubbles enhance the effects of 2 Gy radiation through a synergistic mechanism, resulting in alterations of tumor blood flow. This novel therapy may potentiate lower radiation doses to preferentially target endothelial cells, thus reducing effects on neighboring normal tissue and increasing the efficacy of cancer treatments. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.
Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick
2016-07-01
Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a DVT which can embolize to the lungs and thus should not preclude further workup when clinical suspicion exists for a pulmonary embolus.
Huisman, Merel; Staruch, Robert M; Ladouceur-Wodzak, Michelle; van den Bosch, Maurice A; Burns, Dennis K; Chhabra, Avneesh; Chopra, Rajiv
2015-01-01
Ultrasound (US)-guided high intensity focused ultrasound (HIFU) has been proposed for noninvasive treatment of neuropathic pain and has been investigated in in-vivo studies. However, ultrasound has important limitations regarding treatment guidance and temperature monitoring. Magnetic resonance (MR)-imaging guidance may overcome these limitations and MR-guided HIFU (MR-HIFU) has been used successfully for other clinical indications. The primary purpose of this study was to evaluate the feasibility of utilizing 3D MR neurography to identify and guide ablation of peripheral nerves using a clinical MR-HIFU system. Volumetric MR-HIFU was used to induce lesions in the peripheral nerves of the lower limbs in three pigs. Diffusion-prep MR neurography and T1-weighted images were utilized to identify the target, plan treatment and immediate post-treatment evaluation. For each treatment, one 8 or 12 mm diameter treatment cell was used (sonication duration 20 s and 36 s, power 160-300 W). Peripheral nerves were extracted < 3 hours after treatment. Ablation dimensions were calculated from thermal maps, post-contrast MRI and macroscopy. Histological analysis included standard H&E staining, Masson's trichrome and toluidine blue staining. All targeted peripheral nerves were identifiable on MR neurography and T1-weighted images and could be accurately ablated with a single exposure of focused ultrasound, with peak temperatures of 60.3 to 85.7°C. The lesion dimensions as measured on MR neurography were similar to the lesion dimensions as measured on CE-T1, thermal dose maps, and macroscopy. Histology indicated major hyperacute peripheral nerve damage, mostly confined to the location targeted for ablation. Our preliminary results indicate that targeted peripheral nerve ablation is feasible with MR-HIFU. Diffusion-prep 3D MR neurography has potential for guiding therapy procedures where either nerve targeting or avoidance is desired, and may also have potential for post-treatment verification of thermal lesions without contrast injection.
Seabra, Mariana; Felino, António; Nogueira, Rosete; Valente, Francisco; Braga, Ana Cristina; Vaz, Paula
2015-05-12
Hypodontia is the most frequent developmental anomaly of the orofacial complex, and its detection in prenatal ultrasound may indicate the presence of congenital malformations, genetic syndromes and chromosomal abnormalities. To date, only a few studies have evaluated the histological relationship of human tooth germs identified by two-dimensional (2D) ultrasonography. In order to analyze whether two-dimensional ultrasonography of tooth germs may be successfully used for identifying genetic syndromes, prenatal ultrasound images of fetal tooth germs obtained from a Portuguese population sample were compared with histological images obtained from fetal autopsies. Observational, descriptive, transversal study. The study protocol followed the ethical principles outlined by the Helsinki Declaration and was approved by the Ethics Committee of the School of Dental Medicine, University of Porto (FMDUP, Porto, Portugal) and of the Centro Hospitalar de Vila Nova de Gaia/Espinho (CHVNG/EPE, Porto, Portugal) as well as by the CGC Genetics Embryofetal Pathology Laboratory. Eighty-five fetuses examined by prenatal ultrasound screening from May 2011 to August 2012 had an indication for autopsy following spontaneous fetal death or medical termination of pregnancy. Of the 85 fetuses, 37 (43.5%) were randomly selected for tooth germ evaluation by routine histopathological analysis. Fetuses who were up to 30 weeks of gestation, and whose histological pieces were not representative of all maxillary tooth germs was excluded. Twenty four fetus between the 13(th) and 30(th) weeks of gestation fulfilled the parameters to autopsy. Twenty four fetuses were submitted to histological evaluation and were determined the exact number, morphology, and mineralization of their tooth germs. All tooth germs were identifiable with ultrasonography as early as the 13(th) week of gestation. Of the fetuses autopsied, 41.7% had hypodontia (29.1% maxillary hypodontia and 20.9% mandibular hypodontia). This results indicate that prenatal ultrasound is a reliable method for detecting of hypodontia an early gestational ages. Further studies with larger samples are needed to confirm these results.
Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David
2016-01-01
Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.
Api, Murat
2009-12-01
A number of novel surgical modalities that destroy or remove some ovarian tissue to restore ovarian function in patients with polycystic ovary syndrome have been described in the most recent literature. Although these modalities were reported to have easy applicability and low cost with shorter hospital stay, the efficacy and safety concerns need to be discussed extensively.
Francis, Colin Anthony; Hoffer, Joaquín Andrés; Reynolds, Steven
2016-01-01
Mechanical ventilation is associated with atrophy and weakness of the diaphragm. Ultrasound is an easy noninvasive way to track changes in thickness of the diaphragm. To validate ultrasound as a means of tracking thickness of the diaphragm in patients undergoing mechanical ventilation by evaluating interobserver and interoperator reliability and to collect initial data on the relationship of mode of ventilation to changes in the diaphragm. Daily ultrasound images of the quadriceps and the right side of the diaphragm were acquired in 8 critically ill patients receiving various modes of mechanical ventilation. Thickness of the diaphragm and the quadriceps was measured, and changes with time were noted. Interoperator and interobserver reliability were measured. Intraclass correlation coefficients between operators and between observers for thickness of the diaphragm and quadriceps were greater than 0.95, indicating excellent interoperator and interobserver reliability. Patients receiving assist-control ventilation (n = 4) showed a mean decline in diaphragm thickness of 4.7% per day. Patients receiving pressure support ventilation (n = 8) showed a mean increase in diaphragm thickness of 1.5% per day. Quadriceps thickness declined in all participants (n = 8) at a mean rate of 2.0% per day. Use of ultrasound to measure thickness of the diaphragm in 8 intensive care patients undergoing various modes of mechanical ventilation was feasible and yielded reproducible results. Ultrasound tracking of changes in thickness of the diaphragm in this small sample indicated that the thickness decreased during assist-control mode and increased during pressure support mode. ©2016 American Association of Critical-Care Nurses.
Bubbles with shock waves and ultrasound: a review.
Ohl, Siew-Wan; Klaseboer, Evert; Khoo, Boo Cheong
2015-10-06
The study of the interaction of bubbles with shock waves and ultrasound is sometimes termed 'acoustic cavitation'. It is of importance in many biomedical applications where sound waves are applied. The use of shock waves and ultrasound in medical treatments is appealing because of their non-invasiveness. In this review, we present a variety of acoustics-bubble interactions, with a focus on shock wave-bubble interaction and bubble cloud phenomena. The dynamics of a single spherically oscillating bubble is rather well understood. However, when there is a nearby surface, the bubble often collapses non-spherically with a high-speed jet. The direction of the jet depends on the 'resistance' of the boundary: the bubble jets towards a rigid boundary, splits up near an elastic boundary, and jets away from a free surface. The presence of a shock wave complicates the bubble dynamics further. We shall discuss both experimental studies using high-speed photography and numerical simulations involving shock wave-bubble interaction. In biomedical applications, instead of a single bubble, often clouds of bubbles appear (consisting of many individual bubbles). The dynamics of such a bubble cloud is even more complex. We shall show some of the phenomena observed in a high-intensity focused ultrasound (HIFU) field. The nonlinear nature of the sound field and the complex inter-bubble interaction in a cloud present challenges to a comprehensive understanding of the physics of the bubble cloud in HIFU. We conclude the article with some comments on the challenges ahead.
Bubbles with shock waves and ultrasound: a review
Ohl, Siew-Wan; Klaseboer, Evert; Khoo, Boo Cheong
2015-01-01
The study of the interaction of bubbles with shock waves and ultrasound is sometimes termed ‘acoustic cavitation'. It is of importance in many biomedical applications where sound waves are applied. The use of shock waves and ultrasound in medical treatments is appealing because of their non-invasiveness. In this review, we present a variety of acoustics–bubble interactions, with a focus on shock wave–bubble interaction and bubble cloud phenomena. The dynamics of a single spherically oscillating bubble is rather well understood. However, when there is a nearby surface, the bubble often collapses non-spherically with a high-speed jet. The direction of the jet depends on the ‘resistance' of the boundary: the bubble jets towards a rigid boundary, splits up near an elastic boundary, and jets away from a free surface. The presence of a shock wave complicates the bubble dynamics further. We shall discuss both experimental studies using high-speed photography and numerical simulations involving shock wave–bubble interaction. In biomedical applications, instead of a single bubble, often clouds of bubbles appear (consisting of many individual bubbles). The dynamics of such a bubble cloud is even more complex. We shall show some of the phenomena observed in a high-intensity focused ultrasound (HIFU) field. The nonlinear nature of the sound field and the complex inter-bubble interaction in a cloud present challenges to a comprehensive understanding of the physics of the bubble cloud in HIFU. We conclude the article with some comments on the challenges ahead. PMID:26442143
Portable bladder ultrasound: an evidence-based analysis.
2006-01-01
The aim of this review was to assess the clinical utility of portable bladder ultrasound. TARGET POPULATION AND CONDITION Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of the 3 studies concerning portable bladder ultrasound found the device acceptable to use. However, one study did not find the device as accurate for small PVR volume as for catheterization and another found that the device overestimated catheterized bladder volume. In the remaining study, the authors reported that when the device's hand-held ultrasound transducers (scanheads) were aimed improperly, bladders were missed, or lateral borders of bladders were missed resulting in partial bladder volume measurements and underestimation of PVR measurements. They concluded that caution should be used in interpreting PVR volume measured by portable bladder ultrasound machines and that catheterization may be the preferred assessment modality if an accurate PVR measurement is necessary. All 3 studies with post-operative populations found portable bladder ultrasound use to be reasonably acceptable. Two studies reported that the device overestimated catheter-derived bladder volumes, one by 7% and the other by 21 mL. The third study reported the opposite, that the device underestimated catheter bladder volume by 39 mL but that the results remained acceptable In rehabilitation settings, 2 studies found portable bladder ultrasound to underestimate catheter-derived bladder volumes; yet, both authors concluded that the mean errors were within acceptable limits. In patients with neurogenic bladder problems, 2 studies found portable bladder ultrasound to be an acceptable alternative to catheterization despite the fact that it was not as accurate as catheterization for obtaining bladder volumes. Lastly, examinations concerning avoidance of negative health outcomes showed that, after use of the portable bladder ultrasound, unnecessary catheterizations and UTIs were decreased. Unnecessary catheterizations avoided ranged from 16% to 47% in the selected articles. Reductions in UTI ranged from 38% to 72%. In sum, all but one study advocated the use of portable bladder ultrasound as an alternative to catheterization. An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario's complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional training packages, batteries and battery chargers, software, gel pads, and yearly warranties are additional costs. Studies indicate that portable bladder ultrasound is a cost-effective technology, because it avoids costs associated with catheterization equipment, saves nursing time, and reduces catheter-related complications and UTIs. The use of portable bladder ultrasound device will affect the patient directly in terms of health outcomes. Its use avoids the trauma related to the urinary tract that catheterization inflicts, and does not result in UTIs. In addition, patients prefer it, because it preserves dignity and reduces discomfort.
2006-01-01
Executive Summary Objective The aim of this review was to assess the clinical utility of portable bladder ultrasound. Clinical Need: Target Population and Condition Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. The Technology Being Reviewed Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. Review Strategy To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Summary of Findings Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of the 3 studies concerning portable bladder ultrasound found the device acceptable to use. However, one study did not find the device as accurate for small PVR volume as for catheterization and another found that the device overestimated catheterized bladder volume. In the remaining study, the authors reported that when the device’s hand-held ultrasound transducers (scanheads) were aimed improperly, bladders were missed, or lateral borders of bladders were missed resulting in partial bladder volume measurements and underestimation of PVR measurements. They concluded that caution should be used in interpreting PVR volume measured by portable bladder ultrasound machines and that catheterization may be the preferred assessment modality if an accurate PVR measurement is necessary. All 3 studies with post-operative populations found portable bladder ultrasound use to be reasonably acceptable. Two studies reported that the device overestimated catheter-derived bladder volumes, one by 7% and the other by 21 mL. The third study reported the opposite, that the device underestimated catheter bladder volume by 39 mL but that the results remained acceptable In rehabilitation settings, 2 studies found portable bladder ultrasound to underestimate catheter-derived bladder volumes; yet, both authors concluded that the mean errors were within acceptable limits. In patients with neurogenic bladder problems, 2 studies found portable bladder ultrasound to be an acceptable alternative to catheterization despite the fact that it was not as accurate as catheterization for obtaining bladder volumes. Lastly, examinations concerning avoidance of negative health outcomes showed that, after use of the portable bladder ultrasound, unnecessary catheterizations and UTIs were decreased. Unnecessary catheterizations avoided ranged from 16% to 47% in the selected articles. Reductions in UTI ranged from 38% to 72%. In sum, all but one study advocated the use of portable bladder ultrasound as an alternative to catheterization. Economic Analysis An economic analysis estimating the budget-impact of BladderScan in complex continuing care facilities was completed. The analysis results indicated a $192,499 (Cdn) cost-savings per year per facility and a cost-savings of $2,887,485 (Cdn) for all 15 CCC facilities. No economic analysis was completed for long-term care and acute care facilities due to lack of data. Considerations for Policy Development Rapid diffusion of portable bladder ultrasound technology is expected. Recently, the IC5 project on improving continence care in Ontario’s complex continuing care centres piloted portable bladder ultrasound at 12 sites. Preliminary results were promising. Many physicians and health care facilities already have portable bladder ultrasound devices. However, portable bladder ultrasound devices for PVR measurement are not in use at most health care facilities in Ontario and Canada. The Verathon Corporation (Bothell, Wisconsin, United States), which patents BladderScan, is the sole licensed manufacturer of the portable bladder ultrasound in Canada. Field monopoly may influence the rising costs of portable bladder ultrasound, particularly when faced with rapid expansion of the technology. Several thousand residents of Ontario would benefit from portable bladder ultrasound. The number of residents of Ontario that would benefit from the technology is difficult to quantify, because the incidence and prevalence of incontinence are grossly under-reported. However, long-term care and complex continuing care institutions would benefit greatly from portable bladder ultrasound, as would numerous rehabilitation units, postsurgical care units, and urology clinics. The cost of the portable bladder ultrasound devices ranges from $17,698.90 to $19,565.95 (Cdn) (total purchase price per unit as quoted by the manufacturer). Additional training packages, batteries and battery chargers, software, gel pads, and yearly warranties are additional costs. Studies indicate that portable bladder ultrasound is a cost-effective technology, because it avoids costs associated with catheterization equipment, saves nursing time, and reduces catheter-related complications and UTIs. The use of portable bladder ultrasound device will affect the patient directly in terms of health outcomes. Its use avoids the trauma related to the urinary tract that catheterization inflicts, and does not result in UTIs. In addition, patients prefer it, because it preserves dignity and reduces discomfort. PMID:23074481
Survey of current practice in clinical transvaginal ultrasound scanning in the UK
Shaw, Adam; Lees, Christoph
2015-01-01
During transvaginal ultrasound scanning, the fetus and other sensitive tissues are placed close to the transducer. Heating of these tissues occurs by direct conduction from the transducer and by absorption of ultrasound in the tissue. The extent of any heating will depend on the equipment and settings used, the duration of the scan, imaging modes and other aspects of scanning practice. To ensure that scans are performed with minimum risk, staff should have an appropriate knowledge of safety and follow guidelines issued by professional bodies. An online survey aiming to document current practice in transvaginal ultrasound in the UK was created and distributed to individuals performing this type of scanning. The survey posed questions about the respondents, the departments where scans were performed, the equipment used, knowledge of ultrasound safety, scanning practice and the frequency, duration and mode of transvaginal ultrasound scans for gynaecology, obstetrics and fertility applications. In all, 294 responses were obtained, mostly from sonographers (94%). From the analysis of the responses, it was clear that there was a good understanding of the general meaning of thermal and mechanical index and high awareness of guidelines issued by professional bodies. However, 40% of respondents stated that they rarely or never monitor Thermal or Mechanical indices during scanning. Scanning practice was consistent in terms of the duration of scans, scan protocols followed and use of imaging modes. The results highlight the importance of continued ultrasound safety training and promotion of safety guidelines to users. PMID:27433250
Qin, Dui; Zhang, Lei; Chang, Nan; Ni, Pengying; Zong, Yujin; Bouakaz, Ayache; Wan, Mingxi; Feng, Yi
2018-02-06
In this study, the bioeffects of acoustic droplet vaporization (ADV) on adjacent cells were investigated by evaluating the real-time cell response at the single-cell level in situ, using a combined ultrasound-exposure and optical imaging system. Two imaging modalities, high-speed and fluorescence imaging, were used to observe ADV bubble dynamics and to evaluate the impact on cell membrane permeabilization (i.e., sonoporation) using propidium iodide (PI) uptake as an indicator. The results indicated that ADV mainly led to irreversible rather than reversible sonoporation. Further, the rate of irreversible sonoporation significantly increased with increasing nanodroplet concentration, ultrasound amplitude, and pulse duration. The results suggested that sonoporation is correlated to the rapid formation, expansion, and contraction of ADV bubbles near cells, and strongly depends on ADV bubble size and bubble-to-cell distance when subjected to short ultrasound pulses (1 μs). Moreover, the displacement of ADV bubbles was larger when using a long ultrasound pulse (20 μs), resulting in considerable cell membrane deformation and a more irreversible sonoporation rate. During sonoporation, cell membrane blebbing as a recovery manoeuvre was also investigated, indicating the essential role of Ca 2+ influx in the membrane blebbing response. This study has helped us gain further insights into the dynamic behavior of ADV bubbles near cells, ADV bubble-cell interactions, and real-time cell response, which are invaluable in the development of optimal approaches for ADV-associated theranostic applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Endoscopic ultrasound in gastroenterology: from diagnosis to therapeutic implications.
Mekky, Mohamed A; Abbas, Wael A
2014-06-28
Since its advent in 1980, the scope of endoscopic ultrasound (EUS) has grown to include a wide range of indications, and it is now being incorporated as an integral part of everyday practice in the field of gastroenterology. Its use is extending from an adjuvant imaging aid to utilization as a therapeutic tool for various gastrointestinal disorders. EUS was first used to visualize remote organs, such as the pancreas and abdominal lymph nodes. When fine needle aspiration was introduced, the indications for EUS expanded to include tissue sampling for diagnostic purposes. At the same time, the needle can be used to convey a potential therapy to the internal organs, allowing access to remote sites. In this review, we aim to highlight the expanding spectrum of EUS indications and uses in the field of gastroenterology.
Ultrasound-guided peripheral nerve interventions for common pain disorders
Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh
2018-01-01
There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534
Ultrasound pretreatment for enhanced biogas production from olive mill wastewater.
Oz, Nilgun Ayman; Uzun, Alev Cagla
2015-01-01
This study investigates applicability of low frequency ultrasound technology to olive mill wastewaters (OMWs) as a pretreatment step prior to anaerobic batch reactors to improve biogas production and methane yield. OMWs originating from three phase processes are characterized with high organic content and complex nature. The treatment of the wastewater is problematic and alternative treatment options should be investigated. In the first part of the study, OMW samples were subjected to ultrasound at a frequency of 20kHz with applied powers varying between 50 and 100W under temperature controlled conditions for different time periods in order to determine the most effective sonication conditions. The level of organic matter solubilization at ultrasound experiments was assessed by calculating the ratio of soluble chemical oxygen demand/total chemical oxygen demand (SCOD/TCOD). The results revealed that the optimum ultrasonic condition for diluted OMW is 20kHz, 0.4W/mL for 10min. The application of ultrasound to OMW increased SCOD/TCOD ratio from 0.59 to 0.79. Statistical analysis (Friedman's tests) show that ultrasound was significantly effective on diluted OMW (p<0.05) in terms of SCOD parameter, but not for raw OMW (p>0.05). For raw OMW, this increase has been found to be limited due to high concentration of suspended solids (SS). In the second part of the study, biogas and methane production rates of anaerobic batch reactor fed with the ultrasound pretreated OMW samples were compared with the results of control reactor fed with untreated OMW in order to determine the effect of sonication. A nonparametric statistical procedure, Mann-Whitney U test, was used to compare biogas and methane production from anaerobic batch reactors for control and ultrasound pretreated samples. Results showed that application of low frequency ultrasound to OMW significantly improved both biogas and methane production in anaerobic batch reactor fed with the wastewater (p<0.05). Anaerobic batch reactor fed with ultrasound pretreated diluted OMW produced approximately 20% more biogas and methane compared with the untreated one (control reactor). The overall results indicated that low frequency ultrasound pretreatment increased soluble COD in OMW and subsequently biogas production. Copyright © 2014 Elsevier B.V. All rights reserved.
Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.
Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak
2012-06-01
Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the pulsatility index, the limits of agreement were -0.80 to 0.53. The correlation of the size of the measurement and the mean difference in methods (-0.14; 95% CI = -0.28, 0.01) was not statistically significant (r = 0.31, P = 0.17). For the resistive index, the limits of agreement were -0.22 to 0.12. The correlation of the size of the measurement and the mean difference in methods (-0.05; 95% CI = -0.09, -0.01) was not statistically significant (r = 0.10, P = 0.65). This study confirms the feasibility of obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children. Angle-independent TEE Doppler-derived indices show significant concordance with those derived by TAU. Further studies are required to assess whether this correlation holds true in the presence of renal pathology. This technique has the potential to help modulate intraoperative interventions based on their impact on renal variables and may prove helpful in the perioperative period for children at risk of acute kidney injury.
Kong, C; Nimmo, L; Elatrozy, T; Anyaoku, V; Hughes, C; Robinson, S; Richmond, W; Elkeles, R S
2001-06-01
We have studied the relationships between hepatic lipase activity, smoking, dyslipidaemia insulin resistance, and early atherosclerosis in 67 Type 2 diabetic subjects, 47 non-smokers and 20 smokers. Insulin resistance was measured using an insulin modified frequently sampled intravenous glucose tolerance test. Early atherosclerosis was assessed using high-resolution ultrasound to measure carotid intima media thickness (IMT) and an arterial ultrasonic score (AUS). Smokers had higher serum cholesterol and triglyceride, lower HDL and HDL2 cholesterol as well as increased hepatic lipase activity. They were also more insulin resistant than non-smokers. Smokers also had higher patient AUS scores. On multiple regression analysis, hepatic lipase activity emerged as the most significant variable affecting patient AUS. We suggest that smoking accentuates the dyslipidaemia of Type 2 diabetic subjects and this is associated with increased hepatic lipase activity. This may be one mechanism whereby smoking further increases the risk of cardiovascular disease in Type 2 diabetes.
De Coninck, Kyra; Hambly, Karen; Dickinson, John W; Passfield, Louis
2018-06-01
Chronic lower back pain is still regarded as a poorly understood multifactorial condition. Recently, the thoracolumbar fascia complex has been found to be a contributing factor. Ultrasound imaging has shown that people with chronic lower back pain demonstrate both a significant decrease in shear strain, and a 25% increase in thickness of the thoracolumbar fascia. There is sparse data on whether medical practitioners agree on the level of disorganisation in ultrasound images of thoracolumbar fascia. The purpose of this study was to establish inter-rater reliability of the ranking of architectural disorganisation of thoracolumbar fascia on a scale from 'very disorganised' to 'very organised'. An exploratory analysis was performed using a fully crossed design of inter-rater reliability. Thirty observers were recruited, consisting of 21 medical doctors, 7 physiotherapists and 2 radiologists, with an average of 13.03 ± 9.6 years of clinical experience. All 30 observers independently rated the architectural disorganisation of the thoracolumbar fascia in 30 ultrasound scans, on a Likert-type scale with rankings from 1 = very disorganised to 10 = very organised. Internal consistency was assessed using Cronbach's alpha. Krippendorff's alpha was used to calculate the overall inter-rater reliability. The Krippendorf's alpha was .61, indicating a modest degree of agreement between observers on the different morphologies of thoracolumbar fascia.The Cronbach's alpha (0.98), indicated that there was a high degree of consistency between observers. Experience in ultrasound image analysis did not affect constancy between observers (Cronbach's range between experienced and inexperienced raters: 0.95 and 0.96 respectively). Medical practitioners agree on morphological features such as levels of organisation and disorganisation in ultrasound images of thoracolumbar fascia, regardless of experience. Further analysis by an expert panel is required to develop specific classification criteria for thoracolumbar fascia.
Thaokar, Chandrajit; Rossi, Michael R; Rabin, Yoed
2016-02-01
The current study aims at developing computational tools in order to gain information about the thermal history in areas invisible to ultrasound imaging during cryosurgery. This invisibility results from the high absorption rate of the ultrasound energy by the frozen region, which leads to an apparent opacity in the cryotreated area and a shadow behind it. A proof-of-concept for freezing-front estimation is demonstrated in the current study, using the new potential-field analogy method (PFAM). This method is further integrated with a recently developed temperature-field reconstruction method (TFRM) to estimate the temperature distribution within the frozen region. This study uses prostate cryosurgery as a developmental model and trans-rectal ultrasound imaging as a choice of practice. Results of this study indicate that the proposed PFAM is a viable and computationally inexpensive solution to estimate the extent of freezing in the acoustic shadow region. Comparison of PFAM estimations and experimental data shows an average mismatch of less than 2 mm in freezing-front location, which is comparable to the uncertainty in ultrasound imaging. Comparison of the integrated PFAM + TFRM scheme with a full-scale finite-elements analysis (FEA) indicates an average mismatch of 0.9 mm for the freezing front location and 0.1 mm for the lethal temperature isotherm of -45 °C. Comparison of the integrated PFAM + TFRM scheme with experimental temperature measurements show a difference in the range of 2 °C and 6 °C for selected points of measurement. Results of this study demonstrate the integrated PFAM + TFRM scheme as a viable and computationally inexpensive means to gain information about the thermal history in the frozen region during ultrasound-monitored cryosurgery. Copyright © 2015 Elsevier Inc. All rights reserved.
Speksnijder, L; Rousian, M; Steegers, E A P; Van Der Spek, P J; Koning, A H J; Steensma, A B
2012-07-01
Virtual reality is a novel method of visualizing ultrasound data with the perception of depth and offers possibilities for measuring non-planar structures. The levator ani hiatus has both convex and concave aspects. The aim of this study was to compare levator ani hiatus volume measurements obtained with conventional three-dimensional (3D) ultrasound and with a virtual reality measurement technique and to establish their reliability and agreement. 100 symptomatic patients visiting a tertiary pelvic floor clinic with a normal intact levator ani muscle diagnosed on translabial ultrasound were selected. Datasets were analyzed using a rendered volume with a slice thickness of 1.5 cm at the level of minimal hiatal dimensions during contraction. The levator area (in cm(2)) was measured and multiplied by 1.5 to get the levator ani hiatus volume in conventional 3D ultrasound (in cm(3)). Levator ani hiatus volume measurements were then measured semi-automatically in virtual reality (cm(3) ) using a segmentation algorithm. An intra- and interobserver analysis of reliability and agreement was performed in 20 randomly chosen patients. The mean difference between levator ani hiatus volume measurements performed using conventional 3D ultrasound and virtual reality was 0.10 (95% CI, - 0.15 to 0.35) cm(3). The intraclass correlation coefficient (ICC) comparing conventional 3D ultrasound with virtual reality measurements was > 0.96. Intra- and interobserver ICCs for conventional 3D ultrasound measurements were > 0.94 and for virtual reality measurements were > 0.97, indicating good reliability for both. Levator ani hiatus volume measurements performed using virtual reality were reliable and the results were similar to those obtained with conventional 3D ultrasonography. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
A deep learning approach for real time prostate segmentation in freehand ultrasound guided biopsy.
Anas, Emran Mohammad Abu; Mousavi, Parvin; Abolmaesumi, Purang
2018-06-01
Targeted prostate biopsy, incorporating multi-parametric magnetic resonance imaging (mp-MRI) and its registration with ultrasound, is currently the state-of-the-art in prostate cancer diagnosis. The registration process in most targeted biopsy systems today relies heavily on accurate segmentation of ultrasound images. Automatic or semi-automatic segmentation is typically performed offline prior to the start of the biopsy procedure. In this paper, we present a deep neural network based real-time prostate segmentation technique during the biopsy procedure, hence paving the way for dynamic registration of mp-MRI and ultrasound data. In addition to using convolutional networks for extracting spatial features, the proposed approach employs recurrent networks to exploit the temporal information among a series of ultrasound images. One of the key contributions in the architecture is to use residual convolution in the recurrent networks to improve optimization. We also exploit recurrent connections within and across different layers of the deep networks to maximize the utilization of the temporal information. Furthermore, we perform dense and sparse sampling of the input ultrasound sequence to make the network robust to ultrasound artifacts. Our architecture is trained on 2,238 labeled transrectal ultrasound images, with an additional 637 and 1,017 unseen images used for validation and testing, respectively. We obtain a mean Dice similarity coefficient of 93%, a mean surface distance error of 1.10 mm and a mean Hausdorff distance error of 3.0 mm. A comparison of the reported results with those of a state-of-the-art technique indicates statistically significant improvement achieved by the proposed approach. Copyright © 2018 Elsevier B.V. All rights reserved.
Impact of Focused Ultrasound-enhanced Drug Delivery on Survival in Rats with Glioma
NASA Astrophysics Data System (ADS)
Treat, Lisa Hsu; Zhang, Yongzhi; McDannold, Nathan; Hynynen, Kullervo
2009-04-01
Malignancies of the brain remain difficult to treat with chemotherapy because the selective permeability of the blood-brain barrier (BBB) blocks many potent agents from reaching their target. Previous studies have illustrated the feasibility of drug and antibody delivery across the BBB using MRI-guided focused ultrasound. In this study, we investigated the impact of focused ultrasound-enhanced delivery of doxorubicin on survival in rats with aggressive glioma. Sprague-Dawley rats were implanted with 9 L gliosarcoma cells in the brain. Eight days after implantation, each rat received one of the following: (1) no treatment (control), (2) a single treatment with microbubble-enhanced MRI-guided focused ultrasound (FUS only), (3) a single treatment with i.v. liposomal doxorubicin (DOX only), or (4) a single treatment with microbubble-enhanced MRI-guided focused ultrasound and concurrent i.v. injections of liposomal doxorubicin (FUS+DOX). The survival time from implantation to death or euthanasia was recorded. We observed a modest but significant increase in median survival time in rats treated with combined MRI-guided focused ultrasound chemotherapy, compared to chemotherapy alone (p<0.001). There was no significant improvement in survival between those who received stand-alone chemotherapy and those who did not receive any treatment (p>0.10). Our study demonstrates for the first time a therapeutic benefit achieved with ultrasound-enhanced drug delivery across the blood-brain barrier. This confirmation of efficacy in an in vivo tumor model indicates that targeted drug delivery using MRI-guided focused ultrasound has the potential to have a major impact on the treatment of patients with brain tumors and other neurological disorders.
Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth
NASA Astrophysics Data System (ADS)
Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus
2013-03-01
Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.
van der Ven, Myrthe; Karreman, Maren C; Weel, Angelique E A M; Tchetverikov, Ilja; Vis, Marijn; Nijsten, Tamar E C; Hazes, Johanna M W; Luime, Jolanda J
2016-01-01
Part of the psoriasis patients with musculoskeletal complaints will have inflammation of the entheses. Entheseal inflammation is difficult to assess by clinical examination only. Therefore, we aimed to determine the frequency of clinically relevant ultrasound inflammation at the most commonly assessed entheses (MASEI; Madrid Sonographic Enthesis Index) in primary care psoriasis patients with one or more tender entheses. Adult primary care psoriasis patients with musculoskeletal complaints (tender enthesis or arthritis at physical examination) had an ultrasound examination of seven entheses according to the MASEI. Clinically relevant ultrasound inflammation was defined as active inflammation on ultrasound in combination with at least one clinical feature at the same enthesis. Active ultrasound inflammation contained positive power Doppler signal or in case of the plantar aponeurosis increased thickness. Structural changes entailed calcifications, enthesophytes, increased thickness, hypoechogeneicity indicating irregular fibre structure and erosions. Clinically, an enthesis was scored positive by a tender enthesis at clinical examination, reported pain in the history or self-reported pain in the questionnaires. Of 542 primary care psoriasis patient, 111 patients had tender entheses and/or arthritis. These patients were both clinically and ultrasonographically evaluated. Active ultrasound inflammation accompanied with pain or tenderness at the enthesis was found in 36% of the patients (n=40). Most common were inflammation at the knee (n=11) and at the plantar aponeurosis (n=10). Structural changes were observed in 95% of the psoriasis patients independent of their clinical manifestation. We found concurrent presence of ultrasound inflammatory changes and clinical symptoms in 36% of the primary care psoriasis patients who had tenderness at one or more entheseal sites.
Yan, Fei; Xu, Xiuxia; Chen, Yihan; Deng, Zhiting; Liu, Hongmei; Xu, Jianrong; Zhou, Jie; Tan, Guanghong; Wu, Junru; Zheng, Hairong
2015-10-01
The design and fabrication of targeted ultrasound contrast agents are key factors in the success of ultrasound molecular imaging applications. Here, we introduce a transformable αvβ3 integrin-targeted microbubble (MB) by incorporation of iRGD-lipopeptides into the MB membrane for non-invasive ultrasound imaging of tumor angiogenesis. First, the iRGD-lipopeptides were synthesized by conjugating iRGD peptides to distearoylphosphatidylethanolamine-polyethylene glycol 2000-maleimide. The resulting iRGD-lipopeptides were used for fabrication of the iRGD-carrying αvβ3 integrin-targeted MBs (iRGD-MBs). The binding specificity of iRGD-MBs for endothelial cells was found to be significantly stronger than that of control MBs (p < 0.01) under in vitro static and dynamic conditions. The binding of iRGD-MBs on the endothelial cells was competed off by pre-incubation with the anti-αv or anti-β3 antibody (p < 0.01). Ultrasound images taken of mice bearing 4T1 breast tumors after intravenous injections of iRGD-MBs or control MBs revealed strong contrast enhancement within the tumors from iRGD-MBs but not from the control MBs; the mean acoustic signal intensity was 10.71 ± 2.75 intensity units for iRGD-MBs versus 1.13 ± 0.18 intensity units for the control MBs (p < 0.01). The presence of αvβ3 integrin was confirmed by immunofluorescence staining. These data indicate that iRGD-MBs can be used as an ultrasound imaging probe for the non-invasive molecular imaging of tumor angiogenesis, and may have further implications for ultrasound image-guided tumor targeting drug delivery. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
Mitri, F.G.; Davis, B.J.; Greenleaf, J.F.; Fatemi, M.
2010-01-01
Background Permanent prostate brachytherapy (PPB) is a common treatment for early stage prostate cancer. While the modern approach using trans-rectal ultrasound guidance has demonstrated excellent outcome, the efficacy of PPB depends on achieving complete radiation dose coverage of the prostate by obtaining a proper radiation source (seed) distribution. Currently, brachytherapy seed placement is guided by trans-rectal ultrasound imaging and fluoroscopy. A significant percentage of seeds are not detected by trans-rectal ultrasound because certain seed orientations are invisible making accurate intra-operative feedback of radiation dosimetry very difficult, if not impossible. Therefore, intra-operative correction of suboptimal seed distributions cannot easily be done with current methods. Vibro-acoustography (VA) is an imaging modality that is capable of imaging solids at any orientation, and the resulting images are speckle free. Objective and methods The purpose of this study is to compare the capabilities of VA and pulse-echo ultrasound in imaging PPB seeds at various angles and show the sensitivity of detection to seed orientation. In the VA experiment, two intersecting ultrasound beams driven at f1 = 3.00 MHz and f2 = 3.020 MHz respectively were focused on the seeds attached to a latex membrane while the amplitude of the acoustic emission produced at the difference frequency 20 kHz was detected by a low frequency hydrophone. Results Finite element simulations and results of experiments conducted under well-controlled conditions in a water tank on a series of seeds indicate that the seeds can be detected at any orientation with VA, whereas pulse-echo ultrasound is very sensitive to the seed orientation. Conclusion It is concluded that vibro-acoustography is superior to pulse-echo ultrasound for detection of PPB seeds. PMID:18538365
Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.
Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum
2016-01-01
Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the concentration of microbubbles in case stable cavitation is predominant.
Routine screening for fetal anomalies: expectations.
Goldberg, James D
2004-03-01
Ultrasound has become a routine part of prenatal care. Despite this, the sensitivity and specificity of the procedure is unclear to many patients and healthcare providers. In a small study from Canada, 54.9% of women reported that they had received no information about ultrasound before their examination. In addition, 37.2% of women indicated that they were unaware of any fetal problems that ultrasound could not detect. Most centers that perform ultrasound do not have their own statistics regarding sensitivity and specificity; it is necessary to rely on large collaborative studies. Unfortunately, wide variations exist in these studies with detection rates for fetal anomalies between 13.3% and 82.4%. The Eurofetus study is the largest prospective study performed to date and because of the time and expense involved in this type of study, a similar study is not likely to be repeated. The overall fetal detection rate for anomalous fetuses was 64.1%. It is important to note that in this study, ultrasounds were performed in tertiary centers with significant experience in detecting fetal malformations. The RADIUS study also demonstrated a significantly improved detection rate of anomalies before 24 weeks in tertiary versus community centers (35% versus 13%). Two concepts seem to emerge from reviewing these data. First, patients must be made aware of the limitations of ultrasound in detecting fetal anomalies. This information is critical to allow them to make informed decisions whether to undergo ultrasound examination and to prepare them for potential outcomes.Second, to achieve the detection rates reported in the Eurofetus study, ultrasound examination must be performed in centers that have extensive experience in the detection of fetal anomalies.
A model of the instantaneous pressure-velocity relationships of the neonatal cerebral circulation.
Panerai, R B; Coughtrey, H; Rennie, J M; Evans, D H
1993-11-01
The instantaneous relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), measured with Doppler ultrasound in the anterior cerebral artery, is represented by a vascular waterfall model comprising vascular resistance, compliance, and critical closing pressure. One min recordings obtained from 61 low birth weight newborns were fitted to the model using a least-squares procedures with correction for the time delay between the BP and CBFV signals. A sensitivity analysis was performed to study the effects of low-pass filtering (LPF), cutoff frequency, and noise on the estimated parameters of the model. Results indicate excellent fitting of the model (F-test, p < 0.0001) when the BP and CBFV signals are LPF at 7.5 Hz. Reconstructed CBFV waveforms using the BP signal and the model parameters have a mean correlation coefficient of 0.94 with the measured flow velocity tracing (N = 232 epochs). The model developed can be useful for interpreting clinical findings and as a framework for research into cerebral autoregulation.
Appraisal of different ultrasonography indices in patients with carotid artery atherosclerosis
Rafati, Mehravar; Havaee, Elham; Moladoust, Hassan; Sehhati, Mohammadreza
2017-01-01
In this study a semi-automated image-processing based method was designed in which the parameters such as intima-media thickness (IMT), resistive index (RI), pulsatility index (PI), dicrotic notch index (DNI), and mean wavelet entropy (MWE) were evaluated in B-mode and Doppler ultrasound in patients presenting with carotid artery atherosclerosis. In a cross-sectional design, 144 men were divided into four groups of control, mild, moderate and severe stenosis subjects. In all individuals, far wall IMT, RI, PI, DNI, and MWE of the left common carotid artery (CCA) were extracted using the proposed method. Our findings showed that the maximum far wall IMT, RI, PI, DNI in the CCA were significantly different in the patients with mild, moderate, and severe stenosis compared to control group (p-value < 0.05), however, there were no significant differences in MWE among the four groups (p-value > 0.05). The proposed method can help physicians to better identify patients at risk of cardiovascular diseases. PMID:28827988
Acoustically driven degradation in single crystalline silicon solar cell
NASA Astrophysics Data System (ADS)
Olikh, O. Ya.
2018-05-01
The influence of ultrasound on current-voltage characteristics of crystalline silicon solar sell was investigated experimentally. The transverse and longitudinal acoustic waves were used over a temperature range of 290-340 K. It was found that the ultrasound loading leads to the reversible decrease in the photogenerated current, open-circuit voltage, fill factor, carrier lifetime, and shunt resistance as well as the increase in the ideality factor. The experimental results were described by using the models of coupled defect level recombination, Shockley-Read-Hall recombination, and dislocation-induced impedance. The contribution of the boron-oxygen related defects, iron-boron pairs, and oxide precipitates to both the carrier recombination and acousto-defect interaction was discussed. The experimentally observed phenomena are associated with the increase in the distance between coupled defects as well as the extension of the carrier capture coefficient of complex point defects and dislocations.
Magnetoacoustic Tomography with Magnetic Induction for Electrical Conductivity based Tissue imaging
NASA Astrophysics Data System (ADS)
Mariappan, Leo
Electrical conductivity imaging of biological tissue has attracted considerable interest in recent years owing to research indicating that electrical properties, especially electrical conductivity and permittivity, are indicators of underlying physiological and pathological conditions in biological tissue. Also, the knowledge of electrical conductivity of biological tissue is of interest to researchers conducting electromagnetic source imaging and in design of devices that apply electromagnetic energy to the body such as MRI. So, the need for a non-invasive, high resolution impedance imaging method is highly desired. To address this need we have studied the magnetoacoustic tomography with magnetic induction (MAT-MI) method. In MAT-MI, the object is placed in a static and a dynamic magnetic field giving rise to ultrasound waves. The dynamic field induces eddy currents in the object, and the static field leads to generation of acoustic vibrations from Lorentz force on the induced currents. The acoustic vibrations are at the same frequency as the dynamic magnetic field, which is chosen to match the ultrasound frequency range. These ultrasound signals can be measured by ultrasound probes and are used to reconstruct MAT-MI acoustic source images using possible ultrasound imaging approaches .The reconstructed high spatial resolution image is indicative of the object's electrical conductivity contrast. We have investigated ultrasound imaging methods to reliably reconstruct the MAT-MI image under the practical conditions of limited bandwidth and transducer geometry. The corresponding imaging algorithm, computer simulation and experiments are developed to test the feasibility of these different methods. Also, in experiments, we have developed a system with the strong static field of an MRI magnet and a strong pulsed magnetic field to evaluate MAT-MI in biological tissue imaging. It can be seen from these simulations and experiments that conductivity boundary images with millimeter resolution can be reliably reconstructed with MAT-MI. Further, to estimate the conductivity distribution throughout the object, we reconstruct a vector source image corresponding to the induced eddy currents. As the current source is uniformly present throughout the object, we are able to reliably estimate the internal conductivity distribution for a more complete imaging. From the computer simulations and experiments it can be seen that MAT-MI method has the potential to be a clinically applicable, high resolution, non-invasive method for electrical conductivity imaging.
A Feasibility Study into the Active Smart Patch Concept for Composite Bonded Repairs
2008-08-01
electrical resistance foil gauges and PVDF (polyvinylidene) piezoelectric film to sense the local strain relaxation that occurs in re- sponse to failure of...structural components, like a wing skin, that are ‘thin’ in comparison to the wavelengths of low frequency ultrasound , and therefore act as efficient...region for the respective excitation frequency. The processed experimental data is compared to theoretical dispersion curves for both Lamb waves and
Acoustic fingerprints of dye-labeled protein submicrosphere photoacoustic contrast agents
NASA Astrophysics Data System (ADS)
McDonald, Michael A.; Jankovic, Ladislav; Shahzad, Khalid; Burcher, Michael; Li, King C. P.
2009-05-01
Dye-labeled protein microspheres, submicron in size and capable of producing thermoelastically generated ultrasound in response to laser stimulation, are presented as contrast agents for photoacoustic imaging. Incident laser energy absorbed by fluorescein isothiocyanate (FITC)-labeled elastin submicrospheres results in thermoelastically generated sound production. Plotted A-line graphs reveal a distinctive morphology and a greater than two orders of magnitude increase in signal amplitude subsequent to converting FITC elastin into submicrospheres (despite a four orders of magnitude decrease in concentration). Evidence of nonlinearity and enhancement of ultrasound backscatter indicate a potential use in contrast-enhanced harmonic imaging. Photoacoustic and ultrasound imaging of FITC-elastin submicrospheres in a water-filled phantom vessel shows enhanced contrast at low concentration and clear delineation of the phantom vessel wall.
Berrebi, Alain; Bardou, Magali; Bessieres, Marie-Hélène; Nowakowska, Dorota; Castagno, Romina; Rolland, Michel; Wallon, Martine; Franck, Jacqueline; Bongain, André; Monnier-Barbarino, Patricia; Assouline, Corinne; Cassaing, Sophie
2007-11-01
We wished to investigate the prognosis of children infected with Toxoplasma gondii during the first trimester of pregnancy and whose ultrasound findings were entirely normal, in order to find out whether congenital toxoplasmosis did or did not justify termination of pregnancy if there was no fetal abnormality on ultrasound. A prospective and retrospective study was carried out by 12 French centers who enrolled 36 children infected with T. gondii during the first trimester of pregnancy and whose ultrasound examinations showed no anomaly. The outcome of these children after the age of 12 months (mean 50 months, range 12-144 months) was analyzed. Of the 36 infected children, 28 (78%) presented subclinical toxoplasmosis. Only specific IgG antibodies persisted after 1 year. The principal manifestation in 7 children (19%) was chorioretinitis without major vision loss. Their intellectual development was entirely normal. One child (3%) developed severe congenital toxoplasmosis. Since 97% of children infected with toxoplasmosis during the first trimester of pregnancy are asymptomatic or only slightly affected, we believe that in such circumstances termination of pregnancy is not indicated. However, appropriate treatment is essential and prenatal ultrasound examinations should be free of any anomaly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobayashi, Masaki, E-mail: masaki@tohtech.ac.jp; Kikuchi, Naoto; Sato, Akihiro
This letter proposes and demonstrates ultrasound-combined optical imaging in dense scattering media. A peroxyoxalate chemiluminescence system that includes fluorophores to chemically excite the pigment is stimulated by ultrasound irradiation with power of less than 0.14 W/cm{sup 2}. Using focused ultrasound, the chemiluminescence is selectively spatially enhanced, which leads to imaging of the pigment when embedded in a light-scattering medium via scanning of the focal point. The ultrasonically enhanced intensity of the chemiluminescence depends on the base intensity of the chemiluminescence without the applied ultrasound irradiation, which thereby enables quantitative determination of the fluorophore concentration. The authors demonstrate the potential of thismore » method to resolve chemiluminescent targets in a dense scattering medium that is comparable to biological tissue. An image was acquired of a chemiluminescent target that included indocyanine green as the fluorophore embedded at a depth of 20 mm in an Intralipid-10% 200 ml/l solution scattering medium (the reduced scattering coefficient was estimated to be approximately 1.3 mm{sup −1}), indicating the potential for expansion of this technique for use in biological applications.« less
Pelliccia, Francesco; Palmiero, Pasquale; Maiello, Maria; Losi, Maria-Angela
2012-07-01
Hand-carried ultrasound devices (HCDs), also named personal use echo, are pocket-size, compact, and battery-equipped echocardiographic systems. They have limited technical capabilities but offer some advantages compared with standard echocardiographic devices due to their simplicity of use, immediate availability at the patient's bedside, transportability, and relatively low cost. Current HCDs are considered as screening tools and are used to complement the physical examination by cardiologists. Many noncardiologic subspecialists, however, have adopted this technologic advancement rapidly raising the concern of an inappropriate use of HCD by health professionals who do not have any specific training. In keeping with the mission of the International Society of Cardiovascular Ultrasound to advance the science and art of cardiovascular ultrasound and encourage the knowledge of this subject, the purpose of this Expert Consensus document is to focus on the training for all health care professionals considering the use of HCD. Accordingly, this paper summarizes general aspects of HCD, such as technical characteristics and clinical indications, and then details the specific training requirements for noncardiologists (i.e., training program, minimum case load, duration, and certification of competence). © 2012, Wiley Periodicals, Inc.
Chou, Ching-Yu; Chen, Li-Ching; Cheong, Mei-Leng; Tsai, Ming-Song
2015-10-01
To examine the association of antenatal renal pelvic dilatation observed on midtrimester ultrasound screening with the presence of hydronephrosis in newborn infants. The records of patients who received fetal ultrasound examination at 18-28 weeks' gestation from May 2008 to March 2012 were retrospectively reviewed. A fetal renal pelvic anterior-posterior (AP) diameter > 4 mm was considered abnormal and ≤ 4 mm was considered normal. On postnatal ultrasound, a renal pelvic AP diameter > 3 mm was considered to indicate hydronephrosis and ≤ 3 mm was considered normal. The association of postnatal hydronephrosis with prenatal pelvic AP diameter was determined using binary logistic regression analysis. The study comprised 1310 newborn infants: 684 (52.2%) male and 626 (47.8%) female. Multivariate analysis showed a right or left prenatal AP renal pelvic diameter > 4 mm was associated with a higher risk of postnatal hydronephrosis compared with a right and left prenatal AP renal pelvic diameter ≤ 4 mm. Boys had a higher risk for postnatal hydronephrosis than girls (odds ratio = 2.42, p < 0.05). An antenatal renal pelvic AP diameter > 4 mm on midtrimester ultrasound is predictive of postnatal hydronephrosis. Copyright © 2015. Published by Elsevier B.V.
Influence of the osteosynthesis plate on ultrasound propagation in the bone
Bezuti, Márcio Takey; Mandarano-Filho, Luiz Garcia; Barbieri, Giuliano; Mazzer, Nilton; Barbieri, Cláudio Henrique
2014-01-01
Objective: To analyze the influence of steel plates for osteosynthesis on the velocity of ultrasound propagation (VU) through the bone. Methods: The transverse coronal and sagittal velocity of ultrasound propagation underwater were measured on the intact bone and then on assemblies of the same bone with two types of osteosynthesis plates (DCP and semi tubular), fixed onto the dorsal side of the bones. The first arriving signal (FAS) was the ultrasound parameter used, taking the coronal and sagittal diameters as the distances to calculate velocity. Intergroup statistical comparisons were made at significance level of 1% (p<0.01). Results: Velocity was higher on the intact bones than on the bone-plate assemblies and higher for the semitubular than for the compression plates, although differences were not statistically significant for most comparisons (p=0.0132 to 0.9884), indicating that the steel plates do not interfere significantly with ultrasound wave propagation through the bone-plate assemblies. Conclusion: The velocity reduction effect was attributed to the greater reflection coefficient of the steel as compared to that of bone and water. Ultrasonometry can, thus, be used in the evaluation of healing of fractures fixed with steel plates. Experimental Study. PMID:25328436
Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe
Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.
2014-01-01
Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628
Echo Decorrelation Imaging of Rabbit Liver and VX2 Tumor during In Vivo Ultrasound Ablation.
Fosnight, Tyler R; Hooi, Fong Ming; Keil, Ryan D; Ross, Alexander P; Subramanian, Swetha; Akinyi, Teckla G; Killin, Jakob K; Barthe, Peter G; Rudich, Steven M; Ahmad, Syed A; Rao, Marepalli B; Mast, T Douglas
2017-01-01
In open surgical procedures, image-ablate ultrasound arrays performed thermal ablation and imaging on rabbit liver lobes with implanted VX2 tumor. Treatments included unfocused (bulk ultrasound ablation, N = 10) and focused (high-intensity focused ultrasound ablation, N = 13) exposure conditions. Echo decorrelation and integrated backscatter images were formed from pulse-echo data recorded during rest periods after each therapy pulse. Echo decorrelation images were corrected for artifacts using decorrelation measured prior to ablation. Ablation prediction performance was assessed using receiver operating characteristic curves. Results revealed significantly increased echo decorrelation and integrated backscatter in both ablated liver and ablated tumor relative to unablated tissue, with larger differences observed in liver than in tumor. For receiver operating characteristic curves computed from all ablation exposures, both echo decorrelation and integrated backscatter predicted liver and tumor ablation with statistically significant success, and echo decorrelation was significantly better as a predictor of liver ablation. These results indicate echo decorrelation imaging is a successful predictor of local thermal ablation in both normal liver and tumor tissue, with potential for real-time therapy monitoring. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Ultrasound-mediated ocular delivery of therapeutic agents: a review.
Lafond, Maxime; Aptel, Florent; Mestas, Jean-Louis; Lafon, Cyril
2017-04-01
Due to numerous anatomical and physiological barriers, ocular drug delivery remains a major limitation in the treatment of diseases such as glaucoma, macular degeneration or inflammatory diseases. To date, only invasive approaches provide clinically effective results. Ultrasound can be defined as the propagation of a high-frequency sound wave exposing the propagation media to mechanical and thermal effects. Ultrasound has been proposed as a non-invasive physical agent for increasing therapeutic agent delivery in various fields of medicine. Areas covered: An update on recent advances in transscleral and transcorneal ultrasound-mediated drug delivery is presented. Efficient drug delivery is achieved in vitro, ex vivo and in vivo for various types of materials. Numerous studies indicate that efficacy is related to cavitation. Although slight reversible effects can be observed on the corneal epithelium, efficient drug delivery can be performed without causing damage to the cornea. Expert opinion: Recent developments prove the potential of ultrasound-mediated ocular drug delivery. Cavitation appears to be a preponderant mechanism, opening a way to treatment monitoring by cavitation measurement. Even if no clinical studies have yet been performed, the promising results summarized here are promoting developments toward clinical applications, particularly in assessing the safety of the technique.
Fortuitously discovered liver lesions.
Dietrich, Christoph F; Sharma, Malay; Gibson, Robert N; Schreiber-Dietrich, Dagmar; Jenssen, Christian
2013-06-07
The fortuitously discovered liver lesion is a common problem. Consensus might be expected in terms of its work-up, and yet there is none. This stems in part from the fact that there is no preventive campaign involving the early detection of liver tumors other than for patients with known liver cirrhosis and oncological patients. The work-up (detection and differential diagnosis) of liver tumors comprises theoretical considerations, history, physical examination, laboratory tests, standard ultrasound, Doppler ultrasound techniques, contrast-enhanced ultrasound (CEUS), computed tomography and magnetic resonance imaging, as well as image-guided biopsy. CEUS techniques have proved to be the most pertinent method; these techniques became part of the clinical routine about 10 years ago in Europe and Asia and are used for a variety of indications in daily clinical practice. CEUS is in many cases the first and also decisive technical intervention for detecting and characterizing liver tumors. This development is reflected in many CEUS guidelines, e.g., in the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines 2004, 2008 and 2012 as well as the recently published World Federation for Ultrasound in Medicine and Biology-EFSUMB guidelines 2012. This article sets out considerations for making a structured work-up of incidental liver tumors feasible.
Gao, Mengdi; Yu, Yanyan; Zhao, Huixia; Li, Guofeng; Jiang, Hongyang; Wang, Congzhi; Cai, Feiyan; Chan, Leanne Lai-Hang; Chiu, Bernard; Qian, Wei; Qiu, Weibao; Zheng, Hairong
2017-09-01
Millions of people around the world suffer from varying degrees of vision loss (including complete blindness) because of retinal degenerative diseases. Artificial retinal prosthesis, which is usually based on electrical neurostimulation, is the most advanced technology for different types of retinal degeneration. However, this technology involves placing a device into the eyeball, and such a highly invasive procedure is inevitably highly risk and expensive. Ultrasound has been demonstrated to be a promising technology for noninvasive neurostimulation, making it possible to stimulate the retina and induce action potentials similar to those elicited by light stimulation. However, the technology of ultrasound retinal stimulation still requires considerable developments before it could be applied clinically. This paper proposes a novel contact-lens array transducer for use in an ultrasound retinal prosthesis (USRP). The transducer was designed in the shape of a contact lens so as to facilitate acoustic coupling with the eye liquid. The key parameters of the ultrasound transducer were simulated, and results are presented that indicate the achievement of 2-D pattern generation and that the proposed contact-lens array is suitable for multiple-focus neurostimulation, and can be used in a USRP.
Liu, Xiao; Shi, Jun; Zhou, Shichong; Lu, Minhua
2014-01-01
The dimensionality reduction is an important step in ultrasound image based computer-aided diagnosis (CAD) for breast cancer. A newly proposed l2,1 regularized correntropy algorithm for robust feature selection (CRFS) has achieved good performance for noise corrupted data. Therefore, it has the potential to reduce the dimensions of ultrasound image features. However, in clinical practice, the collection of labeled instances is usually expensive and time costing, while it is relatively easy to acquire the unlabeled or undetermined instances. Therefore, the semi-supervised learning is very suitable for clinical CAD. The iterated Laplacian regularization (Iter-LR) is a new regularization method, which has been proved to outperform the traditional graph Laplacian regularization in semi-supervised classification and ranking. In this study, to augment the classification accuracy of the breast ultrasound CAD based on texture feature, we propose an Iter-LR-based semi-supervised CRFS (Iter-LR-CRFS) algorithm, and then apply it to reduce the feature dimensions of ultrasound images for breast CAD. We compared the Iter-LR-CRFS with LR-CRFS, original supervised CRFS, and principal component analysis. The experimental results indicate that the proposed Iter-LR-CRFS significantly outperforms all other algorithms.
Liu, Jian; Gao, Yun-Hua; Li, Ding-Dong; Gao, Yan-Chun; Hou, Ling-Mi; Xie, Ting
2014-01-01
To compare the value of contrast-enhanced ultrasound (CEUS) qualitative and quantitative analysis in the identification of breast tumor lumps. Qualitative and quantitative indicators of CEUS for 73 cases of breast tumor lumps were retrospectively analyzed by univariate and multivariate approaches. Logistic regression was applied and ROC curves were drawn for evaluation and comparison. The CEUS qualitative indicator-generated regression equation contained three indicators, namely enhanced homogeneity, diameter line expansion and peak intensity grading, which demonstrated prediction accuracy for benign and malignant breast tumor lumps of 91.8%; the quantitative indicator-generated regression equation only contained one indicator, namely the relative peak intensity, and its prediction accuracy was 61.5%. The corresponding areas under the ROC curve for qualitative and quantitative analyses were 91.3% and 75.7%, respectively, which exhibited a statistically significant difference by the Z test (P<0.05). The ability of CEUS qualitative analysis to identify breast tumor lumps is better than with quantitative analysis.
Epstein, E; Van Calster, B; Timmerman, D; Nikman, S
2016-01-01
To compare subjective ultrasound assessment and the ADNEX model with ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer. This was a prospective study including 143 consecutive women with disseminated malignancy of unknown primary origin, with a pelvic tumor/carcinosis. Women underwent either transvaginal or transrectal ultrasound as well as transabdominal ultrasound examination followed by tru-cut biopsy. The ultrasound examiner assessed tumor morphology, spread in the pelvis and abdomen, and predicted tumor origin as primary ovarian or metastatic using both subjective assessment and the ADNEX model. Histology from tru-cut biopsy served as the gold standard for assessment of diagnostic accuracy. Biopsy adequacy and the complication rate were assessed. Tru-cut biopsy was performed transvaginally in 131/143 (92%) women. Two women needed inpatient care (one had abdominal wall hematoma, and one infection). Biopsy resulted in a conclusive diagnosis in 126/143 (88%) women, amongst whom cytoreductive surgery was performed in 30/126 confirming the diagnosis in all cases. Non-ovarian metastatic cancer was found in 37/126 (29%) women and primary ovarian cancer in 89/126 (71%) women. Subjective ultrasound evaluation had a sensitivity of 82% (73/89) and a specificity of 70% (26/37) in predicting primary ovarian cancer. The ADNEX model had an area under the receiver-operating characteristics curve of 0.891 (95% CI, 0.794-0.946) (in women with an ovarian lesion, n = 104). Tumor origin was associated with age, CA 125, previous neoplasia, presence of omental cake and tumor mobility. Subjective ultrasound assessment and the ADNEX model can both be used to predict whether a pelvic tumor is metastatic and of non-ovarian origin, indicating the need for tru-cut biopsy, which is associated with very few complications and will provide a conclusive diagnosis in nine out of 10 women. Copyright © 2015 ISUOG. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Wang, Zuojun; Komatsu, Teppei; Mitsumura, Hidetaka; Nakata, Norio; Ogawa, Takeki; Iguchi, Yasuyuki; Yokoyama, Masayuki
2017-05-01
Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. Previously, we reported substantial and periodic fluctuation of ultrasound transmittance through a bone-phantom plate following changes to ultrasound frequency, the thickness of the bone-phantom plate, and the distance between a transducer and the bone-phantom plate. In the present study, we clarify the transmittance behavior of medium-frequency ultrasound (from 400kHz to 600kHz) through the human skull, and examine reduction of the transmittance fluctuation. For the study, we measured transmittance of sinusoidal ultrasound waves at 400kHz, 500kHz, and 600kHz at 13 temple spots on 3 human skulls by changing the distance between a transducer and the skull bone, and found substantial and periodic fluctuation in the transmittance behaviors for these sinusoidal voltage excitations. Degrees of the fluctuation varied depending on the measurement spots. A fluctuation ratio between the maximum transmittance and the minimum transmittance reached 3 in some spots. This large transmittance fluctuation is considered to be a risk factor for sonothrombolysis therapies. We examined a modulated ultrasound wave to reduce the fluctuation, and succeeded in obtaining considerable reduction. The average fluctuation ratios for 400-kHz, 500-kHz, and 600-kHz waves were 2.38, 2.38, and 2.07, respectively. We successfully reduced the ratio to 1.72 by using a periodic selection of random frequency (PSRF)-type of modulation wave. The thus obtained results indicate that attention to the fluctuation in ultrasound transmittance through the skull is necessary for safe and effective sonothrombolysis therapies, and that modulated ultrasound waves constitute a powerful method for reducing the risk of fluctuation. Copyright © 2017 Elsevier B.V. All rights reserved.
Ultrasound assisted biogas production from landfill leachate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oz, Nilgün Ayman, E-mail: nilgunayman@comu.edu.tr; Yarimtepe, Canan Can
Highlights: • Effect of low frequency ultrasound pretreatment on leachate was investigated. • Three different ultrasound energy inputs (200, 400 and 600 W/l) was applied. • Low-frequency ultrasound treatment increased soluble COD in landfill leachate. • Application of ultrasound to leachate increased biogas production about 40%. • Application of ultrasound to leachate increased total methane production rate about 20%. - Abstract: The aim of this study is to increase biogas production and methane yield from landfill leachate in anaerobic batch reactors by using low frequency ultrasound as a pretreatment step. In the first part of the study, optimum conditions formore » solubilization of organic matter in leachate samples were investigated using various sonication durations at an ultrasound frequency of 20 kHz. The level of organic matter solubilization during ultrasonic pretreatment experiments was determined by calculating the ratio of soluble chemical oxygen demand (sCOD) to total chemical oxygen demand (tCOD). The sCOD/tCOD ratio was increased from 47% in raw leachate to 63% after 45 min sonication at 600 W/l. Non-parametric Friedman’s test indicated that ultrasonic pretreatment has a significant effect on sCOD parameter for leachate (p < 0.05). In the second part of the study, anaerobic batch reactors were operated for both ultrasonically pretreated and untreated landfill leachate samples in order to assess the effect of sonication on biogas and methane production rate. In anaerobic batch reactor feed with ultrasonically pretreated leachate, 40% more biogas was obtained compared to the control reactor. For statistical analysis, Mann–Whitney U test was performed to compare biogas and methane production rates for raw and pretreated leachate samples and it has been found that ultrasonic pretreatment significantly enhanced biogas and methane production rates from leachate (p < 0.05) in anaerobic batch reactors. The overall results showed that low frequency ultrasound pretreatment can be potentially used for wastewater management especially with integration of anaerobic processes.« less
NASA Astrophysics Data System (ADS)
Tarapacki, Christine; Kuebler, Wolfgang M.; Tabuchi, Arata; Karshafian, Raffi
2017-03-01
Background: The application of ultrasound and microbubbles at therapeutic conditions has been shown to improve delivery of molecules, cause vasoconstriction, modulate blood flow and induce a vascular shut down in in vivo cancerous tissues. The underlying mechanism has been associated with the interaction of ultrasonically-induced microbubble oscillation and cavitation with the blood vessel wall. In this study, the effect of ultrasound and microbubbles on blood flow and vascular architecture was studied using a fertilized chicken egg CAM (chorioallantoic membrane) model. Methods: CAM at day 12 of incubation (Hamburger-Hamilton stage 38-40) were exposed to ultrasound at varying acoustic pressures (160, 240 and 320 kPa peak negative pressure) in the presence of Definity microbubbles and 70 kDa FITC dextran fluorescent molecules. A volume of 50 µL Definity microbubbles were injected into a large anterior vein of the CAM prior to ultrasound exposure. The ultrasound treatment sequence consisted of 5 s exposure at 500 kHz frequency, 8 cycles and 1 kHz pulse repetition frequency with 5 s off for a total exposure of 2 minutes. Fluorescent videos and images of the CAM vasculature were acquired using intravital microscopy prior, during and following the ultrasound exposure. Perfusion was quantified by measuring the length of capillaries in a region of interest using Adobe Illustrator. Results and Discussion: The vascular bioeffects induced by USMB increased with acoustic peak negative pressure. At 160 kPa, no visible differences were observed compared to the control. At 240 kPa, a transient decrease in perfusion with subsequent recovery within 15 minutes was observed, whereas at 320 kPa, the fluorescent images showed an irreversible vascular damage. The study indicates that a potential mechanism for the transient decrease in perfusion may be related to blood coagulation. The results suggest that ultrasound and microbubbles can induce reversible and irreversible vascular changes depending on the ultrasound exposure pressure.
Dell'Atti, Lucio; Russo, Gian Rosario
2011-01-01
The process of organizing a ultrasound service nowadays can be improved by properly managing the user's request, the speed of response and safety, the standardization of methods and skills. The outpatients at our uro-andrologic ultrasound clinic (O.U. of Urology in Ferrara) received a questionnaire each; we administered a total of 640 questionnaires. The number of questionnaires collected was 532. Patients were asked to give an assessment of services using a qualitative method according to a 4-parameter response scale: very satisfied, satisfied, dissatisfied, very dissatisfied. The identification of indicators to be monitored by the user's perceived quality was accomplished by establishing the correlation coefficient between different parameters of analysis and an overall rating of the sample. Some of these parameters were: the relationship with the practitioner, the availability of doctors, the ability of doctors for reassurance, the completeness of information and facilities hygiene conditions. When these parameters vary, positively or negatively, also the citizen's overall opinion changes. The customer satisfaction is an important component of the quality of care, it represents both an indicator of the effectiveness of health intervention and the ability to meet quality requirements of the health service organization. The objective of an ultrasound service should be to provide, within a reasonable timeframe, the supply of high quality with qualified personnel, with adequate tools and procedures.
Mulik, Rohit S; Bing, Chenchen; Ladouceur-Wodzak, Michelle; Munaweera, Imalka; Chopra, Rajiv; Corbin, Ian R
2016-03-01
Focused ultrasound exposures in the presence of microbubbles can achieve transient, non-invasive, and localized blood-brain barrier (BBB) opening, offering a method for targeted delivery of therapeutic agents into the brain. Low-density lipoprotein (LDL) nanoparticles reconstituted with docosahexaenoic acid (DHA) could have significant therapeutic value in the brain, since DHA is known to be neuroprotective. BBB opening was achieved using pulsed ultrasound exposures in a localized brain region in normal rats, after which LDL nanoparticles containing the fluorescent probe DiR (1,1'-Dioctadecyl-3,3,3',3'-Tetramethylindotricarbocyanine Iodide) or DHA were administered intravenously. Fluorescent imaging of brain tissue from rats administered LDL-DiR demonstrated strong localization of fluorescence signal in the exposed hemisphere. LDL-DHA administration produced 2 × more DHA in the exposed region of the brain, with a corresponding increase in Resolvin D1 levels, indicating DHA was incorporated into cells and metabolized. Histological evaluation did not indicate any evidence of increased tissue damage in exposed brain regions compared to normal brain. This work demonstrates that localized delivery of DHA to the brain is possible using systemically-administered LDL nanoparticles combined with pulsed focused ultrasound exposures in the brain. This technology could be used in regions of acute brain injury or as a means to target infiltrating tumor cells in the brain. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mulik, Rohit S.; Bing, Chenchen; Ladouceur-Wodzak, Michelle; Munaweera, Imalka; Chopra, Rajiv; Corbin, Ian R.
2016-01-01
Focused ultrasound exposures in the presence of microbubbles can achieve transient, non-invasive, and localized blood-brain barrier (BBB) opening, offering a method for targeted delivery of therapeutic agents into the brain. Low-density lipoprotein (LDL) nanoparticles reconstituted with docosahexaenoic acid (DHA) could have significant therapeutic value in the brain, since DHA is known to be neuroprotective. BBB opening was achieved using pulsed ultrasound exposures in a localized brain region in normal rats, after which LDL nanoparticles containing the fluorescent probe DiR (1,1′-Dioctadecyl-3,3,3′,3′-Tetramethylindotricarbocyanine Iodide) or DHA were administered intravenously. Fluorescent imaging of brain tissue from rats administered LDL-DiR demonstrated strong localization of fluorescence signal in the exposed hemisphere. LDL-DHA administration produced 2× more DHA in the exposed region of the brain, with a corresponding increase in Resolvin D1 levels, indicating DHA was incorporated into cells and metabolized. Histological evaluation did not indicate any evidence of increased tissue damage in exposed brain regions compared to normal brain. This work demonstrates that localized delivery of DHA to the brain is possible using systemically-administered LDL nanoparticles combined with pulsed focused ultrasound exposures in the brain. This technology could be used in regions of acute brain injury or as a means to target infiltrating tumor cells in the brain. PMID:26790145
Effects of fatty infiltration in human livers on the backscattered statistics of ultrasound imaging.
Wan, Yung-Liang; Tai, Dar-In; Ma, Hsiang-Yang; Chiang, Bing-Hao; Chen, Chin-Kuo; Tsui, Po-Hsiang
2015-06-01
Ultrasound imaging has been widely applied to screen fatty liver disease. Fatty liver disease is a condition where large vacuoles of triglyceride fat accumulate in liver cells, thereby altering the arrangement of scatterers and the corresponding backscattered statistics. In this study, we used ultrasound Nakagami imaging to explore the effects of fatty infiltration in human livers on the statistical distribution of backscattered signals. A total of 107 patients volunteered to participate in the experiments. The livers were scanned using a clinical ultrasound scanner to obtain the raw backscattered signals for ultrasound B-mode and Nakagami imaging. Clinical scores of fatty liver disease for each patient were determined according to a well-accepted sonographic scoring system. The results showed that the Nakagami image can visualize the local backscattering properties of liver tissues. The Nakagami parameter increased from 0.62 ± 0.11 to 1.02 ± 0.07 as the fatty liver disease stage increased from normal to severe, indicating that the backscattered statistics vary from pre-Rayleigh to Rayleigh distributions. A significant positive correlation (correlation coefficient ρ = 0.84; probability value (p value) < 0.0001) exists between the degree of fatty infiltration and the Nakagami parameter, suggesting that ultrasound Nakagami imaging has potentials in future applications in fatty liver disease diagnosis. © IMechE 2015.
Interactive multimedia for prenatal ultrasound training.
Lee, W; Ault, H; Kirk, J S; Comstock, C H
1995-01-01
This demonstration project examines the utility of interactive multimedia for prenatal ultrasound training. A laser-disc library was linked to a three-dimensional (3-D) heart model and other computer-based training materials through interactive multimedia. A testing module presented ultrasound anomalies and related questions to house-staff physicians through the image library. Users were asked to evaluate these training materials on the basis of perceived instructional value, question content, subjects covered, graphics interface, and ease of use; users were also asked for their comments. House-staff physicians indicated that they consider interactive multimedia to be a helpful adjunct to their core fetal imaging rotation. During a 9-month period, 16 house-staff physicians correctly diagnosed 78 +/- 4% of unknown cases presented through the testing module. The 3-D heart model was also perceived to be a useful teaching aid for spatial orientation skills. Our findings suggest that interactive multimedia and volume visualization models can be used to supplement traditional prenatal ultrasound training. The system provides a broad exposure to ultrasound anomalies, increases opportunities for postnatal correlation, emphasizes motion video for ultrasound training, encourages development of independent diagnostic ability, and helps physicians understand anatomic orientation. We hypothesize that interactive multimedia-based tutorials provide a better overall training experience for house-staff physicians. However, these supplementary methods will require formal evaluation of effectiveness to better understand their potential educational impact.
Li, Jiao; Ding, Tian; Liao, Xinyu; Chen, Shiguo; Ye, Xingqian; Liu, Donghong
2017-09-01
This study evaluated the synergetic effects of ultrasound and slightly acidic electrolyzed water (SAEW) on the inactivation of Staphylococcus aureus using flow cytometry and electron microscopy. The individual ultrasound treatment for 10min only resulted in 0.36logCFU/mL reductions of S. aureus, while the SAEW treatment alone for 10min resulted in 3.06logCFU/mL reductions. The log reductions caused by combined treatment were enhanced to 3.68logCFU/mL, which were greater than the sum of individual treatments. This phenomenon was referred to as synergistic effects. FCM analysis distinguished live and dead cells as well as revealed dynamic changes in the physiological states of S. aureus after different treatments. The combined treatment greatly reduced the number of viable but nonculturable (VBNC) bacteria to 0.07%; in contrast, a single ultrasound treatment for 10min induced the formation of VBNC cells to 45.75%. Scanning and transmission electron microscopy analysis revealed that greater damage to the appearance and ultrastructure of S. aureus were achieved after combined ultrasound-SAEW treatment compared to either treatment alone. These results indicated that combining ultrasound with SAEW is a promising sterilization technology with potential uses for environmental remediation and food preservation. Copyright © 2016 Elsevier B.V. All rights reserved.
[The role of ultrasonography exam in orbital-ocular tumors].
Ciocâlteu, Alina Mihaela; Ardeleanu, S; Checheriţă, I A
2011-01-01
Ophthalmology is one of the specialties that have particularly benefited from the contribution of ultrasonography exam as a method of investigation. Ultrasonography is very much essential for diagnostic to complement other clinical and laboratory investigations, providing images in real time. The basic principle of diagnostic ultrasound is to study and to interpret the changes they undergo when crossing ultrasonic waves diverse biological properties different sound, and such injuries can be traced in the dynamics or can be documented on photographic paper and thus can diagnose correct certain eye diseases. The indications for performing ultrasound consist in: measurement of distances and volumes, examine difficult or inaccessible case of opaque media; ophthalmoscopic view of a mass lesion, examine the orbit or optic nerve. The advantages of ultrasound for orbital-ocular tumors are represented by the fact that ultrasound is a noninvasive method, safe, well tolerated, less expensive that the advantage of determining the position and distance from structures ocular tumor. High frequency ultrasound provides excellent resolution of 0-1 to 0.01 mm, and serial scans allow tracking progress and measuring lesion diameters tumor while allowing monitoring and evaluation of stereotactic radiation treatments applied to small tumors. In conclusion ultrasound allows not only early diagnosis of eye tumors, but accurate assessment of the proposed therapy and of the evolution of detected mass lesions or tumors.
Accuracy of localization of prostate lesions using manual palpation and ultrasound elastography
NASA Astrophysics Data System (ADS)
Kut, Carmen; Schneider, Caitlin; Carter-Monroe, Naima; Su, Li-Ming; Boctor, Emad; Taylor, Russell
2009-02-01
Purpose: To compare the accuracy of detecting tumor location and size in the prostate using both manual palpation and ultrasound elastography (UE). Methods: Tumors in the prostate were simulated using both synthetic and ex vivo tissue phantoms. 25 participants were asked to provide the presence, size and depth of these simulated lesions using manual palpation and UE. Ultrasound images were captured using a laparoscopic ultrasound probe, fitted with a Gore-Tetrad transducer with frequency of 7.5 MHz and a RF capture depth of 4-5 cm. A MATLAB GUI application was employed to process the RF data for ex vivo phantoms, and to generate UE images using a cross-correlation algorithm. Ultrasonix software was used to provide real time elastography during laparoscopic palpation of the synthetic phantoms. Statistical analyses were performed based on a two-tailed, student t-test with α = 0.05. Results: UE displays both a higher accuracy and specificity in tumor detection (sensitivity = 84%, specificity = 74%). Tumor diameters and depths are better estimated using ultrasound elastography when compared with manual palpation. Conclusions: Our results indicate that UE has strong potential in assisting surgeons to intra-operatively evaluate the tumor depth and size. We have also demonstrated that ultrasound elastography can be implemented in a laparoscopic environment, in which manual palpation would not be feasible. With further work, this application can provide accurate and clinically relevant information for surgeons during prostate resection.
Ultrasound Current Source Density Imaging in live rabbit hearts using clinical intracardiac catheter
NASA Astrophysics Data System (ADS)
Li, Qian
Ultrasound Current Source Density Imaging (UCSDI) is a noninvasive modality for mapping electrical activities in the body (brain and heart) in 4-dimensions (space + time). Conventional cardiac mapping technologies for guiding the radiofrequency ablation procedure for treatment of cardiac arrhythmias have certain limitations. UCSDI can potentially overcome these limitations and enhance the electrophysiology mapping of the heart. UCSDI exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity. When an ultrasound beam intersects a current path in a material, the local resistivity of the material is modulated by the ultrasonic pressure, and a change in voltage signal can be detected based on Ohm's Law. The degree of modulation is determined by the AE interaction constant K. K is a fundamental property of any type of material, and directly affects the amplitude of the AE signal detected in UCSDI. UCSDI requires detecting a small AE signal associated with electrocardiogram. So sensitivity becomes a major challenge for transferring UCSDI to the clinic. This dissertation will determine the limits of sensitivity and resolution for UCSDI, balancing the tradeoff between them by finding the optimal parameters for electrical cardiac mapping, and finally test the optimized system in a realistic setting. This work begins by describing a technique for measuring K, the AE interaction constant, in ionic solution and biological tissue, and reporting the value of K in excised rabbit cardiac tissue for the first time. K was found to be strongly dependent on concentration for the divalent salt CuSO4, but not for the monovalent salt NaCl, consistent with their different chemical properties. In the rabbit heart tissue, K was determined to be 0.041 +/- 0.012 %/MPa, similar to the measurement of K in physiologic saline: 0.034 +/- 0.003 %/MPa. Next, this dissertation investigates the sensitivity limit of UCSDI by quantifying the relation between the recording electrode distance and the measured AE signal amplitude in gel phantoms and excised porcine heart tissue using a clinical intracardiac catheter. Sensitivity of UCSDI with catheter was 4.7 microV/mA (R2 = 0.999) in cylindrical gel (0.9% NaCl), and 3.2 microV/mA (R2 = 0.92) in porcine heart tissue. The AE signal was detectable more than 25 mm away from the source in cylindrical gel (0.9% NaCl). Effect of transducer properties on UCSDI sensitivity is also investigated using simulation. The optimal ultrasound transducer parameters chosen for cardiac imaging are center frequency = 0.5 MHz and f/number = 1.4. Last but not least, this dissertation shows the result of implementing the optimized ultrasound parameters in live rabbit heart preparation, the comparison of different recording electrode configuration and multichannel UCSDI recording and reconstruction. The AE signal detected using the 0.5 MHz transducer was much stronger (2.99 microV/MPa) than the 1.0 MHz transducer (0.42 microV/MPa). The clinical lasso catheter placed on the epicardium exhibited excellent sensitivity without being too invasive. 3-dimensional cardiac activation maps of the live rabbit heart using only one pair of recording electrodes were also demonstrated for the first time. Cardiac conduction velocity for atrial (1.31 m/s) and apical (0.67 m/s) pacing were calculated based on the activation maps. The future outlook of this dissertation includes integrating UCSDI with 2-dimensional ultrasound transducer array for fast imaging, and developing a multi-modality catheter with 4-dimensional UCSDI, multi-electrode recording and echocardiography capacity.
Echocardiography and NAFLD (non-alcoholic fatty liver disease).
Trovato, Francesca M; Martines, Giuseppe F; Catalano, Daniela; Musumeci, Giuseppe; Pirri, Clara; Trovato, Guglielmo M
2016-10-15
Non-alcoholic-fatty-liver-disease (NAFLD) is associated with atherosclerosis, increased cardiovascular risks and mortality. We investigated if, independently of insulin resistance, diet, physical activity and obesity, fatty liver involvement has any relationship with echocardiographic measurements in NAFLD. 660 NAFLD and 791 non-NAFLD subjects, referred to the same out-patients medical unit for lifestyle-nutritional prescription, were studied. Congestive heart failure, myocardial infarction, malignancies, diabetes mellitus, extreme obesity, underweight-bad-nourished subjects and renal insufficiency were exclusion criteria. Liver steatosis was assessed by Ultrasound-Bright-Liver-Score (BLS), left ventricular ejection fraction (LVEF), trans-mitral E/A doppler ratio (diastolic relaxation) and left ventricular myocardial mass (LVMM/m(2)) by echocardiography. Doppler Renal artery Resistive Index (RRI), insulin resistance (HOMA) and lifestyle profile were also included in the clinical assessment. LVMM/m(2) is significantly greater in NAFLD, 101.62±34.48 vs. 88.22±25.61, p<0.0001 both in men and in women. Ejection fraction is slightly smaller only in men with NAFLD; no significant difference was observed for the E/A ratio. BMI (30.42±5.49 vs. 24.87±3.81; p<0.0001) and HOMA (2.90±1.70 vs. 1.85±1.25; p: 0.0001) were significantly greater in NAFLD patients. By Multiple-Linear-Regression, NAFLD and unhealthy dietary profile are associated also in lean non-diabetic subjects with lower systolic function, independently of BMI, dietary profile, physical activity, RRI and insulin resistance. NAFLD may be a meaningful early clue suggestive of diminishing heart function, with similar determining factors. NAFLD is amenable to management and improvement by lifestyle change counseling, addressing a dual target: reducing fatty liver, which is easily monitored by ultrasound, and, independently, maintaining a normal heart function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Abu Bakar, Mohd Rizal; Abdul Kadir, Azidah; Abdul Wahab, Siti Zubaidah; Abdul Karim, Ahmad Helmy; Nik Hussain, Nik Hazlina; Mohd Noor, Norhayati; Omar, Julia; Bin Bai Bae, Saringat; Wan Mahmood, Wan Haslindawani; Abdul Razak, Asrenee; Yunus, Rohaizan
2015-01-01
To compare the mean of anteroposterior (AP) measurements of the uterus in longitudinal and oblique transverse planes, and the pulsatility index (PI) and resistive index (RI) of the uterine artery and superficial skin wound artery between patients taking Channa striatus and placebo. Channa striatus, also known as haruan, is a fresh water snakehead fish consumed in many parts of Southeast Asia. Channa striatus is also normally consumed by women postpartum to promote wound healing as well as to reduce post-operative pain. This study is a randomised, double blind, placebo-controlled study conducted in women after Lower Segment Caesarean Section (LSCS). Subjects were randomised to either a Channa striatus or a placebo group and were given a daily dosage of 500 mg of Channa striatus extract or 500 mg maltodextrin, respectively, for six weeks post LSCS. The anteroposterior measurements of the uterus in the longitudinal and oblique transverse planes, and the pulsatility index (PI) and resistive index (RI) of the uterine and superficial skin wound arteries were assessed using pelvic Gray-scale ultrasound and Doppler ultrasound at baseline (Day 3) and at two weeks, four weeks and six weeks post-operatively. Sixty-six subjects were randomised into the study with 33 in the Channa striatus group and 33 in the placebo group. No significant differences were detected in terms of the pulsatility index (PI) and the resistive index (RI) of the uterine and superficial skin wound arteries between the Channa striatus and placebo groups. However, in the Channa striatus group, the AP measurements of the uterus on the longitudinal and oblique transverse planes were significantly lower compared to the placebo group (p<0.05 and p<0.001, respectively). Daily intake of Channa striatus extract results in marked differences compared to placebo in terms of uterine involution and recovery in women post LSCS. www.isrctn.com 11960786.
NASA Astrophysics Data System (ADS)
Adams, Matthew S.; Scott, Serena J.; Salgaonkar, Vasant A.; Jones, Peter D.; Plata-Camargo, Juan C.; Sommer, Graham; Diederich, Chris J.
2015-03-01
An ultrasound applicator for endoluminal thermal therapy of pancreatic tumors has been introduced and evaluated through acoustic/biothermal simulations and ex vivo experimental investigations. Endoluminal therapeutic ultrasound constitutes a minimally invasive conformal therapy and is compatible with ultrasound or MR-based image guidance. The applicator would be placed in the stomach or duodenal lumen, and sonication would be performed through the luminal wall into the tumor, with concurrent water cooling of the wall tissue to prevent its thermal injury. A finite-element (FEM) 3D acoustic and biothermal model was implemented for theoretical analysis of the approach. Parametric studies over transducer geometries and frequencies revealed that operating frequencies within 1-3 MHz maximize penetration depth and lesion volume while sparing damage to the luminal wall. Patient-specific FEM models of pancreatic head tumors were generated and used to assess the feasibility of performing endoluminal ultrasound thermal ablation and hyperthermia of pancreatic tumors. Results indicated over 80% of the volume of small tumors (~2 cm diameter) within 35 mm of the duodenum could be safely ablated in under 30 minutes or elevated to hyperthermic temperatures at steady-state. Approximately 60% of a large tumor (~5 cm diameter) model could be safely ablated by considering multiple positions of the applicator along the length of the duodenum to increase coverage. Prototype applicators containing two 3.2 MHz planar transducers were fabricated and evaluated in ex vivo porcine carcass heating experiments under MR temperature imaging (MRTI) guidance. The applicator was positioned in the stomach adjacent to the pancreas, and sonications were performed for 10 min at 5 W/cm2 applied intensity. MRTI indicated over 400C temperature rise in pancreatic tissue with heating penetration extending 3 cm from the luminal wall.
Al-Juboori, Raed A; Yusaf, Talal; Aravinthan, Vasantha; Bowtell, Leslie
2016-02-01
In this study, the structural alteration to DOC for a range of ultrasound treatments was investigated with chemical fractionation and UV-vis spectroscopic measurement. Ultrasound treatments were applied in continuous and pulsed modes at power levels of 48 and 84 W for effective treatment times of 5 and 15 min. Overall results show that the ultrasound treatments tended to degrade the hydrophobic aromatic fraction, while increasing the hydrophilic fraction to a lesser extent. The highest recorded reduction of hydrophobic DOC (17.8%) was achieved with pulse treatment of 84 W for15 min, while the highest increase in the hydrophilic DOC (10.5%) was obtained with continuous treatment at 84 W and 5 min. The optimal ultrasound treatment conditions were found to be pulse mode at high power and short treatment time, causing a minimal increase in the hydrophilic fraction of 1.3% with moderate removal of the hydrophobic fraction of 15.52%. The same treatment conditions, with longer treatment time, resulted in the highest removal of SUVA254 and SUVA280 of 17.09% and 16.93, respectively. These results indicate the potential for ultrasound treatments in DOC structural alteration. The hydrophobic fraction showed strong and significant correlations with UV absorbance at 254 and 280 nm. A254/A204 also exhibited strong and significant correlations with the hydrophobic/hydrophilic ratio. The other UV ratios (A250/A365 (E2/E3) and A254/A436) had weak and insignificant correlations with the hydrophobic/hydrophilic ratio. This confirms the applicability of UV indices as a suitable surrogate method for estimating the hydrophobic/hydrophilic structure. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Bogomolov, V. V.; Duncan, J. M.; Alferova, I. V.; Dulchavsky, S. A.; Ebert, D.; Hamilton, D. R.; Matveev, V. P.; Sargsyan, A. E.
2008-01-01
Recent advances in remotely guided imaging techniques on ISS allow the acquisition of high quality ultrasound data using crewmember operators with no medical background and minimal training. However, ongoing efforts are required to develop and validate methodology for complex imaging protocols to ensure their repeatability, efficiency, and suitability for use aboard the ISS. This Station Developmental Test Objective (SDTO) tests a cardiovascular evaluation methodology that takes advantage of the ISS Ultrasound capability, the Braslet-M device, and modified respiratory maneuvers (Valsalva and Mueller), to broaden the spectrum of anatomical and functional information on human cardiovascular system during long-duration space missions. The proposed methodology optimizes and combines new and previously demonstrated methods, and is expected to benefit medically indicated assessments, operational research protocols, and data collections for science. Braslet-M is a current Russian operational countermeasure that compresses the upper thigh to impede the venous return from lower extremities. The goal of the SDTO is to establish and validate a repeatable ultrasound-based methodology for the assessment of a number of cardiovascular criteria in microgravity. Braslet-M device is used as a means to acutely alter volume distribution while focused ultrasound measurements are performed. Modified respiratory maneuvers are done upon volume manipulations to record commensurate changes in anatomical and functional parameters. The overall cardiovascular effects of the Braslet-M device are not completely understood, and although not a primary objective of this SDTO, this effort will provide pilot data regarding the suitability of Braslet-M for its intended purpose, effects, and the indications for its use.
Wang, Qing-Fang; Niu, Li-Li; Jiao, Jiao; Guo, Na; Zang, Yu-Ping; Gai, Qing-Yan; Fu, Yu-Jie
2017-11-01
Combined treatment of a novel fungal endophyte Myrothecium verrucaria coupled with ultrasound assistance was conducted to enhance lignin degradation in birch sawdust. The optimum treatment conditions were confirmed as the materials to liquid ratio 1:20, temperature 30°C, time 4days and pH 7, respectively. The results showed that the combined treatment led to the lignin degradation reaching 67.95±2.14%, while the lignin degradation were 45.50±2.12% and 13.75±0.66% with separate fungal treatment and ultrasound treatment, respectively. Moreover, SEM and FTIR analysis indicated that combined treatment significantly altered surface morphology and chemical structure of birch sawdust. The combined treatment greatly increased lignin removal during short time in mild environment. Therefore, these results demonstrated that the combined treatment of fungal endophyte coupled with ultrasound assistance has the high potential for the removal lignin in lignocellulose. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mechanisms for microvascular damage induced by ultrasound-activated microbubbles
NASA Astrophysics Data System (ADS)
Chen, Hong; Brayman, Andrew A.; Evan, Andrew P.; Matula, Thomas J.
2012-10-01
To provide insight into the mechanisms of microvascular damage induced by ultrasound-activated microbubbles, experimental studies were performed to correlate microvascular damage to the dynamics of bubble-vessel interactions. High-speed photomicrography was used to record single microbubbles interacting with microvessels in ex vivo tissue, under the exposure of short ultrasound pulses with a center frequency of 1 MHz and peak negative pressures (PNP) ranging from 0.8-4 MPa. Vascular damage associated with observed bubble-vessel interactions was either indicated directly by microbubble extravasation or examined by transmission electron microscopy (TEM) analyses. As observed previously, the high-speed images revealed that ultrasound-activated microbubbles could cause distention and invagination of adjacent vessel walls, and could form liquid jets in microvessels. Vessel distention, invagination, and liquid jets were associated with the damage of microvessels whose diameters were smaller than those of maximally expanded microbubbles. However, vessel invagination appeared to be the dominant mechanism for the damage of relative large microvessels.
Mechanisms for microvascular damage induced by ultrasound-activated microbubbles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Hong; Brayman, Andrew A.; Evan, Andrew P.
To provide insight into the mechanisms of microvascular damage induced by ultrasound-activated microbubbles, experimental studies were performed to correlate microvascular damage to the dynamics of bubble-vessel interactions. High-speed photomicrography was used to record single microbubbles interacting with microvessels in ex vivo tissue, under the exposure of short ultrasound pulses with a center frequency of 1 MHz and peak negative pressures (PNP) ranging from 0.8-4 MPa. Vascular damage associated with observed bubble-vessel interactions was either indicated directly by microbubble extravasation or examined by transmission electron microscopy (TEM) analyses. As observed previously, the high-speed images revealed that ultrasound-activated microbubbles could cause distentionmore » and invagination of adjacent vessel walls, and could form liquid jets in microvessels. Vessel distention, invagination, and liquid jets were associated with the damage of microvessels whose diameters were smaller than those of maximally expanded microbubbles. However, vessel invagination appeared to be the dominant mechanism for the damage of relative large microvessels.« less
Zou, Tang-Bin; Jia, Qing; Li, Hua-Wen; Wang, Chang-Xiu; Wu, Hong-Fu
2013-01-01
Astaxanthin is a novel carotenoid nutraceutical occurring in many crustaceans and red yeasts. It has exhibited various biological activities including prevention or amelioration of cardiovascular disease, gastric ulcer, hypertension, and diabetic nephropathy. In this study, ultrasound-assisted extraction was developed for the effective extraction of astaxanthin from Haematococcus pluvialis. Some parameters such as extraction solvent, liquid-to-solid ratio, extraction temperature, and extraction time were optimized by single-factor experiment and response surface methodology. The optimal extraction conditions were 48.0% ethanol in ethyl acetate, the liquid-to-solid ratio was 20:1 (mL/g), and extraction for 16.0 min at 41.1 °C under ultrasound irradiation of 200 W. Under optimal conditions, the yield of astaxanthin was 27.58 ± 0.40 mg/g. The results obtained are beneficial for the full utilization of Haematococcus pluvialis, which also indicated that ultrasound-assisted extraction is a very useful method for extracting astaxanthin from marine life. PMID:23697948
Harris, Heather S; Benson, Scott R; James, Michael C; Martin, Kelly J; Stacy, Brian A; Daoust, Pierre-Yves; Rist, Paul M; Work, Thierry M; Balazs, George H; Seminoff, Jeffrey A
2016-03-01
Leatherback turtles (Dermochelys coriacea) undergo substantial cyclical changes in body condition between foraging and nesting. Ultrasonography has been used to measure subcutaneous fat as an indicator of body condition in many species but has not been applied in sea turtles. To validate this technique in leatherback turtles, ultrasound images were obtained from 36 live-captured and dead-stranded immature and adult turtles from foraging and nesting areas in the Pacific and Atlantic oceans. Ultrasound measurements were compared with direct measurements from surgical biopsy or necropsy. Tissue architecture was confirmed histologically in a subset of turtles. The dorsal shoulder region provided the best site for differentiation of tissues. Maximum fat depth values with the front flipper in a neutral (45-90°) position demonstrated good correlation with direct measurements. Ultrasound-derived fat measurements may be used in the future for quantitative assessment of body condition as an index of health in this critically endangered species.
Lim, Tae Ho; Choi, Hyuk Joong; Kang, Bo Seung
2010-01-01
We assessed the feasibility of using a camcorder mobile phone for teleconsulting about cardiac echocardiography. The diagnostic performance of evaluating left ventricle (LV) systolic function was measured by three emergency medicine physicians. A total of 138 short echocardiography video sequences (from 70 subjects) was selected from previous emergency room ultrasound examinations. The measurement of LV ejection fraction based on the transmitted video displayed on a mobile phone was compared with the original video displayed on the LCD monitor of the ultrasound machine. The image quality was evaluated using the double stimulation impairment scale (DSIS). All observers showed high sensitivity. There was an improvement in specificity with the observer's increasing experience of cardiac ultrasound. Although the image quality of video on the mobile phone was lower than that of the original, a receiver operating characteristic (ROC) analysis indicated that there was no significant difference in diagnostic performance. Immediate basic teleconsulting of echocardiography movies is possible using current commercially-available mobile phone systems.
Zechmeister, I
2001-01-01
Continuing medico-technical progress has led to an increasing medicalisation of pregnancy and childbirth. One of the most common technologies in this context is ultrasound. Based on some identified 'pro-technology feminist theories', notably the postmodernist feminist discourse, the technology of ultrasound is analysed focusing mainly on social and political rather than clinical issues. As empirical research suggests, ultrasound is welcomed by the majority of women. The analysis, however, shows that attitudes and decisions of women are influenced by broader social aspects. Furthermore, it demonstrates how the visual technology of ultrasound, in addition to other reproductive technology in maternity care, is linked to the 'personification' of the foetus and has therefore contributed to a new image of the foetus. The exploration of these issues challenges some arguments of feminist discourse. It draws attention to possible adverse implications of the technology for women's reproductive freedom and indicates the importance of the topic for political discussions.
Fu, Fenglian; Lu, Jianwei; Cheng, Zihang; Tang, Bing
2016-03-01
In this paper, the performance and application of zero-valent iron (ZVI) assisted by ultrasonic irradiation for the removal of selenite (Se(IV)) in wastewater was evaluated and reaction mechanism of Se(IV) with ZVI in such systems was investigated. A series of batch experiments were conducted to determine the effects of ultrasound power, pH, ZVI concentration, N2 and air on Se(IV) removal. ZVI before and after reaction with Se(IV) was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). Results indicated that ultrasound can lead to a significant synergy in the removal of Se(IV) by ZVI because ultrasound can promote the generation of OH and accelerate the advanced Fenton process. The primary reaction products of ZVI and Se(IV) were Se(0), ferrihydrite, and Fe2O3. Copyright © 2015 Elsevier B.V. All rights reserved.
Assessment of Spectral Doppler in Preclinical Ultrasound Using a Small-Size Rotating Phantom
Yang, Xin; Sun, Chao; Anderson, Tom; Moran, Carmel M.; Hadoke, Patrick W.F.; Gray, Gillian A.; Hoskins, Peter R.
2013-01-01
Preclinical ultrasound scanners are used to measure blood flow in small animals, but the potential errors in blood velocity measurements have not been quantified. This investigation rectifies this omission through the design and use of phantoms and evaluation of measurement errors for a preclinical ultrasound system (Vevo 770, Visualsonics, Toronto, ON, Canada). A ray model of geometric spectral broadening was used to predict velocity errors. A small-scale rotating phantom, made from tissue-mimicking material, was developed. True and Doppler-measured maximum velocities of the moving targets were compared over a range of angles from 10° to 80°. Results indicate that the maximum velocity was overestimated by up to 158% by spectral Doppler. There was good agreement (<10%) between theoretical velocity errors and measured errors for beam-target angles of 50°–80°. However, for angles of 10°–40°, the agreement was not as good (>50%). The phantom is capable of validating the performance of blood velocity measurement in preclinical ultrasound. PMID:23711503
Jia, Xuejing; Zhang, Chao; Hu, Jie; He, Muxue; Bao, Jiaolin; Wang, Kai; Li, Peng; Chen, Meiwan; Wan, Jianbo; Su, Huanxing; Zhang, Qingwen; He, Chengwei
2015-11-23
Box-Behnken design (BBD), one of the most common response surface methodology (RSM) methods, was used to optimize the experimental conditions for ultrasound-assisted extraction of polysaccharides from Rhynchosia minima root (PRM). The antioxidant abilities and anticancer activity of purified polysaccharide fractions were also measured. The results showed that optimal extraction parameters were as follows: ultrasound exposure time, 21 min; ratio of water to material, 46 mL/g; ultrasound extraction temperature, 63 °C. Under these conditions, the maximum yield of PRM was 16.95%±0.07%. Furthermore, the main monosaccharides of purified fractions were Ara and Gal. PRM3 and PRM5 exhibited remarkable DPPH radical scavenging activities and reducing power in vitro. PRM3 showed strong inhibitory activities on the growth of MCF-7 cells in vitro. The above results indicate that polysaccharides from R. minima root have the potential to be developed as natural antioxidants and anticancer ingredients for the food and pharmaceutical industries.
Harris, Heather S.; Benson, Scott R.; James, Michael C.; Martin, Kelly J.; Stacy, Brian A.; Daoust, Pierre-Yves; Rist, Paul M.; Work, Thierry M.; Balazs, George H.; Seminoff, Jeffrey A.
2016-01-01
Leatherback turtles (Dermochelys coriacea) undergo substantial cyclical changes in body condition between foraging and nesting. Ultrasonography has been used to measure subcutaneous fat as an indicator of body condition in many species but has not been applied in sea turtles. To validate this technique in leatherback turtles, ultrasound images were obtained from 36 live-captured and dead-stranded immature and adult turtles from foraging and nesting areas in the Pacific and Atlantic oceans. Ultrasound measurements were compared with direct measurements from surgical biopsy or necropsy. Tissue architecture was confirmed histologically in a subset of turtles. The dorsal shoulder region provided the best site for differentiation of tissues. Maximum fat depth values with the front flipper in a neutral (45–90°) position demonstrated good correlation with direct measurements. Ultrasound-derived fat measurements may be used in the future for quantitative assessment of body condition as an index of health in this critically endangered species.
Using an ultrasound elasticity microscope to map three-dimensional strain in a porcine cornea.
Hollman, Kyle W; Shtein, Roni M; Tripathy, Sakya; Kim, Kang
2013-08-01
An ultrasound elasticity microscope was used to map 3-D strain volume in an ex vivo porcine cornea to illustrate its ability to measure the mechanical properties of this tissue. Mechanical properties of the cornea play an important role in its function and, therefore, also in ophthalmic diseases such as kerataconus and corneal ectasia. The ultrasound elasticity microscope combines a tightly focused high-frequency transducer with confocal scanning to produce high-quality speckle over the entire volume of tissue. This system and the analysis were able to generate volume maps of compressional strain in all three directions for porcine corneal tissue, more information than any previous study has reported. Strain volume maps indicated features of the cornea and mechanical behavior as expected. These results constitute a step toward better understanding of corneal mechanics and better treatment of corneal diseases. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Matsunaga, Terry O.; Sheeran, Paul S.; Luois, Samantha; Streeter, Jason E.; Mullin, Lee B.; Banerjee, Bhaskar; Dayton, Paul A.
2012-01-01
Recent efforts using perfluorocarbon (PFC) nanoparticles in conjunction with acoustic droplet vaporization has introduced the possibility of expanding the diagnostic and therapeutic capability of ultrasound contrast agents to beyond the vascular space. Our laboratories have developed phase-change nanoparticles (PCNs) from the highly volatile PFCs decafluorobutane (DFB, bp =-2 °C) and octafluoropropane (OFP, bp =-37 °C ) for acoustic droplet vaporization. Studies with commonly used clinical ultrasound scanners have demonstrated the ability to vaporize PCN emulsions with frequencies and mechanical indices that may significantly decrease tissue bioeffects. In addition, these contrast agents can be formulated to be stable at physiological temperatures and the perfluorocarbons can be mixed to modulate the balance between sensitivity to ultrasound and general stability. We herein discuss our recent efforts to develop finely-tuned diagnostic/molecular imaging agents for tissue interrogation. We discuss studies currently under investigation as well as potential diagnostic and therapeutic paradigms that may emerge as a result of formulating PCNs with low boiling point PFCs. PMID:23382775
Izadifar, Zahra; Belev, George; Izadifar, Mohammad; Izadifar, Zohreh; Chapman, Dean
2014-12-07
Observing cavitation bubbles deep within tissue is very difficult. The development of a method for probing cavitation, irrespective of its location in tissues, would improve the efficiency and application of ultrasound in the clinic. A synchrotron x-ray imaging technique, which is capable of detecting cavitation bubbles induced in water by a sonochemistry system, is reported here; this could possibly be extended to the study of therapeutic ultrasound in tissues. The two different x-ray imaging techniques of Analyzer Based Imaging (ABI) and phase contrast imaging (PCI) were examined in order to detect ultrasound induced cavitation bubbles. Cavitation was not observed by PCI, however it was detectable with ABI. Acoustic cavitation was imaged at six different acoustic power levels and six different locations through the acoustic beam in water at a fixed power level. The results indicate the potential utility of this technique for cavitation studies in tissues, but it is time consuming. This may be improved by optimizing the imaging method.
Takeuchi, Ryohei; Harada, Hiroshi; Masuda, Kohji; Ota, Gen-ichiro; Yokoi, Masaki; Teramura, Nobuyasu; Saito, Tomoyuki
2008-06-01
We report the testing of a mobile Robotic Tele-echo system that was placed in an ambulance and successfully transmitted clear real time echo imaging of a patient's abdomen to the destination hospital from where this device was being remotely operated. Two-way communication between the paramedics in this vehicle and a doctor standing by at the hospital was undertaken. The robot was equipped with an ultrasound probe which was remotely controlled by the clinician at the hospital and ultrasound images of the patient were transmitted wirelessly. The quality of the ultrasound images that were transmitted over the public mobile telephone networks and those transmitted over the Multimedia Wireless Access Network (a private networks) were compared. The transmission rate over the public networks and the private networks was approximately 256 Kbps, 3 Mbps respectively. Our results indicate that ultrasound images of far higher definition could be obtained through the private networks.
Manta, Simona; Renault, Gilles; Delalande, Anthony; Couture, Olivier; Lagoutte, Isabelle; Seguin, Johanne; Lager, Franck; Houzé, Pascal; Midoux, Patrick; Bessodes, Michel; Scherman, Daniel; Bureau, Michel-Francis; Marie, Corinne; Pichon, Chantal; Mignet, Nathalie
2017-09-28
Despite the increasing number of clinical trials in gene therapy, no ideal methods still allow non-viral gene transfer in deep tissues such as the liver. We were interested in ultrasound (US)-mediated gene delivery to provide long term liver expression. For this purpose, new positively charged microbubbles were designed and complexed with pFAR4, a highly efficient small length miniplasmid DNA devoid of antibiotic resistance sequence. Sonoporation parameters, such as insonation time, acoustic pressure and duration of plasmid injection were controlled under ultrasound imaging guidance. The optimization of these various parameters was performed by bioluminescence optical imaging of luciferase reporter gene expression in the liver. Mice were injected with 50μg pFAR4-LUC either alone, or complexed with positively charged microbubbles, or co-injected with neutral MicroMarker™ microbubbles, followed by low ultrasound energy application to the liver. Injection of the pFAR4 encoding luciferase alone led to a transient transgene expression that lasted only for two days. The significant luciferase signal obtained with neutral microbubbles decreased over 2days and reached a plateau with a level around 1 log above the signal obtained with pFAR4 alone. With the newly designed positively charged microbubbles, we obtained a much stronger bioluminescence signal which increased over 2days. The 12-fold difference (p<0.05) between MicroMarker™ and our positively charged microbubbles was maintained over a period of 6months. Noteworthy, the positively charged microbubbles led to an improvement of 180-fold (p<0.001) as regard to free pDNA using unfocused ultrasound performed at clinically tolerated ultrasound amplitude. Transient liver damage was observed when using the cationic microbubble-pFAR4 complexes and the optimized sonoporation parameters. Immunohistochemistry analyses were performed to determine the nature of cells transfected. The pFAR4 miniplasmid complexed with cationic microbubbles allowed to transfect mostly hepatocytes compared to its co-injection with MicroMarker™ which transfected more preferentially endothelial cells. Copyright © 2017 Elsevier B.V. All rights reserved.
Yang, Yanqin; Chu, Guohai; Zhou, Guojun; Jiang, Jian; Yuan, Kailong; Pan, Yuanjiang; Song, Zhiyu; Li, Zuguang; Xia, Qian; Lu, Xinbo; Xiao, Weiqiang
2016-03-01
An ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid-phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method was compared with the microwave-assisted extraction coupled to headspace solid-phase microextraction and headspace solid-phase microextraction methods. More types of volatile components were obtained by using the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction technique was a simple, time-saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Miller, Douglas L
2016-12-01
Diagnostic ultrasound can induce pulmonary capillary hemorrhage (PCH) in rats and other mammals. This phenomenon represents the only clearly demonstrated biological effect of (non-contrast enhanced) diagnostic ultrasound and thus presents a uniquely important safety issue. However, the physical mechanism responsible for PCH remains uncertain more than 25 y after its discovery. Experimental research has indicated that neither heating nor acoustic cavitation, the predominant mechanisms for bioeffects of ultrasound, is responsible for PCH. Furthermore, proposed theoretical mechanisms based on gas-body activation, on alveolar resonance and on impulsive generation of liquid droplets all appear unlikely to be responsible for PCH, owing to unrealistic model assumptions. Here, a simple model based on the acoustical radiation surface pressure (ARSP) at a tissue-air interface is hypothesized as the mechanism for PCH. The ARSP model seems to explain some features of PCH, including the approximate frequency independence of PCH thresholds and the dependence of thresholds on biological factors. However, ARSP evaluated for experimental threshold conditions appear to be too weak to fully account for stress failure of pulmonary capillaries, gauging by known stresses for injurious physiologic conditions. Furthermore, consideration of bulk properties of lung tissue suggests substantial transmission of ultrasound through the pleura, with reduced ARSP and potential involvement of additional mechanisms within the pulmonary interior. Although these recent findings advance our knowledge, only a full understanding of PCH mechanisms will allow development of science-based safety assurance for pulmonary ultrasound. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Haichong K.; Aalamifar, Fereshteh; Boctor, Emad M.
2016-04-01
Synthetic aperture for ultrasound is a technique utilizing a wide aperture in both transmit and receive to enhance the ultrasound image quality. The limitation of synthetic aperture is the maximum available aperture size limit determined by the physical size of ultrasound probe. We propose Synthetic-Tracked Aperture Ultrasound (STRATUS) imaging system to overcome the limitation by extending the beamforming aperture size through ultrasound probe tracking. With a setup involving a robotic arm, the ultrasound probe is moved using the robotic arm, while the positions on a scanning trajectory are tracked in real-time. Data from each pose are synthesized to construct a high resolution image. In previous studies, we have demonstrated the feasibility through phantom experiments. However, various additional factors such as real-time data collection or motion artifacts should be taken into account when the in vivo target becomes the subject. In this work, we build a robot-based STRATUS imaging system with continuous data collection capability considering the practical implementation. A curvilinear array is used instead of a linear array to benefit from its wider capture angle. We scanned human forearms under two scenarios: one submerged the arm in the water tank under 10 cm depth, and the other directly scanned the arm from the surface. The image contrast improved 5.51 dB, and 9.96 dB for the underwater scan and the direct scan, respectively. The result indicates the practical feasibility of STRATUS imaging system, and the technique can be potentially applied to the wide range of human body.
Bolandparvaz, Shahram; Moharamzadeh, Payman; Jamali, Kazem; Pouraghaei, Mahboob; Fadaie, Maryam; Sefidbakht, Sepideh; Shahsavari, Kavous
2013-11-01
Long bone fractures are currently diagnosed using radiography, but radiography has some disadvantages (radiation and being time consuming). The present study compared the diagnostic accuracy of bedside ultrasound and radiography in multiple trauma patients at the emergency department (ED). The study assessed 80 injured patients with multiple trauma from February 2011 to July 2012. The patients were older than 18 years and triaged to the cardiopulmonary resuscitation ward of the ED. Bedside ultrasound and radiography were conducted for them. The findings were separately and blindly assessed by 2 radiologists. Sensitivity, specificity, the positive and negative predictive value, and κ coefficient were measured to assess the accuracy and validity of ultrasound as compared with radiography. The sensitivity of ultrasound for diagnosis of limb bone fractures was not high enough and ranged between 55% and 75% depending on the fracture site. The specificity of this diagnostic method had an acceptable range of 62% to 84%. Ultrasound negative prediction value was higher than other indices under study and ranged between 73% and 83%, but its positive prediction value varied between 33.3% and 71%. The κ coefficient for diagnosis of long bone fractures of upper limb (κ = 0.58) and upper limb joints (κ = 0.47) and long bones of lower limb (κ = 0.52) was within the medium range. However, the value for diagnosing fractures of lower limb joints (κ = 0.47) was relatively low. Bedside ultrasound is not a reliable method for diagnosing fractures of upper and lower limb bones compared with radiography. © 2013 Elsevier Inc. All rights reserved.
Segmentation of tumor ultrasound image in HIFU therapy based on texture and boundary encoding
NASA Astrophysics Data System (ADS)
Zhang, Dong; Xu, Menglong; Quan, Long; Yang, Yan; Qin, Qianqing; Zhu, Wenbin
2015-02-01
It is crucial in high intensity focused ultrasound (HIFU) therapy to detect the tumor precisely with less manual intervention for enhancing the therapy efficiency. Ultrasound image segmentation becomes a difficult task due to signal attenuation, speckle effect and shadows. This paper presents an unsupervised approach based on texture and boundary encoding customized for ultrasound image segmentation in HIFU therapy. The approach oversegments the ultrasound image into some small regions, which are merged by using the principle of minimum description length (MDL) afterwards. Small regions belonging to the same tumor are clustered as they preserve similar texture features. The mergence is completed by obtaining the shortest coding length from encoding textures and boundaries of these regions in the clustering process. The tumor region is finally selected from merged regions by a proposed algorithm without manual interaction. The performance of the method is tested on 50 uterine fibroid ultrasound images from HIFU guiding transducers. The segmentations are compared with manual delineations to verify its feasibility. The quantitative evaluation with HIFU images shows that the mean true positive of the approach is 93.53%, the mean false positive is 4.06%, the mean similarity is 89.92%, the mean norm Hausdorff distance is 3.62% and the mean norm maximum average distance is 0.57%. The experiments validate that the proposed method can achieve favorable segmentation without manual initialization and effectively handle the poor quality of the ultrasound guidance image in HIFU therapy, which indicates that the approach is applicable in HIFU therapy.
Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W
2013-01-01
The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.
Ultrasound pre-treatment for anaerobic digestion improvement.
Pérez-Elvira, S; Fdz-Polanco, M; Plaza, F I; Garralón, G; Fdz-Polanco, F
2009-01-01
Prior research indicates that ultrasounds can be used in batch reactors as pre-treatment before anaerobic digestion, but the specific energy required at laboratory-scale is too high. This work evaluates both the continuous ultrasound device performance (efficiency and solubilisation) and the operation of anaerobic digesters continuously fed with sonicated sludge, and presents energy balance considerations. The results of sludge solubilisation after the sonication treatment indicate that, applying identical specific energy, it is better to increase the power than the residence time. Working with secondary sludge, batch biodegradability tests show that by applying 30 kWh/m3 of sludge, it is possible to increase biogas production by 42%. Data from continuous pilot-scale anaerobic reactors (V=100 L) indicate that operating with a conventional HRT=20 d, a reactor fed with pre-treated sludge increases the volatile solids removal and the biogas production by 25 and 37% respectively. Operating with HRT=15 d, the removal efficiency is similar to the obtained with a reactor fed with non-hydrolysed sludge at HTR=20 d, although the specific biogas productivity per volume of reactor is higher for the pretreated sludge. Regarding the energy balance, although for laboratory-scale devices it is negative, full-scale suppliers state a net generation of 3-10 kW per kW of energy used.
Wang, Song; Yang, Wei; Zhang, Hui; Xu, Qian; Yan, Kun
2015-01-01
Objective. To investigate the value of contrast-enhanced ultrasound (CEUS) in transthoracic biopsy of peripheral lung and mediastinal lesions. Methods. Of 142 patients, 82 patients received CEUS before biopsy and were defined as CEUS group. The remaining 60 patients only underwent conventional ultrasound (US) before biopsy and were served as US group. The information of CEUS was used for selecting indication and instructing biopsy. The imaging features, number of punctures, diagnostic successful rate, and complication rate between the two groups were compared. Results. Necrosis was demonstrated in 43.9% of the lesions in CEUS group and in 6.7% of US group (P < 0.001). Detection rate of lesion hidden in pulmonary atelectasis in CEUS group was 13.4%, which was statistically higher than 1.7% of US group (P = 0.013). The diagnostic success rate was 96.3% for CEUS group and 80% for US group, respectively (P = 0.002). The average number of punctures was 2.5 ± 0.7 and 2.6 ± 0.6, respectively. There was no significant difference in complications between CEUS group and US group. Conclusions. CEUS could play an important role in selecting proper indication and improving diagnostic accuracy rate of lung biopsy. PMID:26090391
Ultrasonic control of ceramic membrane fouling: Effect of particle characteristics.
Chen, Dong; Weavers, Linda K; Walker, Harold W
2006-02-01
In this study, the effect of particle characteristics on the ultrasonic control of membrane fouling was investigated. Ultrasound at 20 kHz was applied to a cross-flow filtration system with gamma-alumina membranes in the presence of colloidal silica particles. Experimental results indicated that particle concentration affected the ability of ultrasound to control membrane fouling, with less effective control of fouling at higher particle concentrations. Measurements of sound wave intensity and images of the cavitation region indicated that particles induced additional cavitation bubbles near the ultrasonic source, which resulted in less turbulence reaching the membrane surface and subsequently less effective control of fouling. When silica particles were modified to be hydrophobic, greater inducement of cavitation bubbles near the ultrasonic source occurred for a fixed concentration, also resulting in less effective control of fouling. Particle size influenced the cleaning ability of ultrasound, with better permeate recovery observed with larger particles. Particle size did not affect sound wave intensity, suggesting that the more effective control of fouling by large particles was due to greater lift and cross-flow drag forces on larger particles compared to smaller particles.
Herold, Ingeborg H F; Russo, Gianna; Mischi, Massimo; Houthuizen, Patrick; Saidov, Tamerlan; van het Veer, Marcel; van Assen, Hans C; Korsten, Hendrikus H M
2013-10-17
Contrast-enhanced ultrasound (CEUS) has recently been proposed as a minimally- invasive, alternative method for blood volume measurement. This study aims at comparing the accuracy of CEUS and the classical thermodilution techniques for volume assessment in an in-vitro set-up. The in-vitro set-up consisted of a variable network between an inflow and outflow tube and a roller pump. The inflow and outflow tubes were insonified with an ultrasound array transducer and a thermistor was placed in each tube. Indicator dilution curves were made by injecting indicator which consisted of an ultrasound-contrast-agent diluted in ice-cold saline. Both acoustic intensity- and thermo-dilution curves were used to calculate the indicator mean transit time between the inflow and outflow tube. The volumes were derived by multiplying the estimated mean transit time by the flow rate. We compared the volumes measured by CEUS with the true volumes of the variable network and those measured by thermodilution by Bland-Altman and intraclass-correlation analysis. The measurements by CEUS and thermodilution showed a very strong correlation (rs = 0.94) with a modest volume underestimation by CEUS of -40 ± 28 mL and an overestimation of 84 ± 62 mL by thermodilution compared with the true volumes. Both CEUS and thermodilution showed a high statistically significant correlation with the true volume (rs = 0.97 (95% CI, 0.95 - 0.98; P<0.0001) and rs = 0.96 (95% CI, 0.94 - 0.98; P<0.0001, respectively). CEUS volume estimation provides a strong correlation with both the true volumes in-vitro and volume estimation by thermodilution. It may therefore represent an interesting alternative to the standard, invasive thermodilution technique.
Can Anal Sphincter Defects Be Identified by Palpation?
Shek, Ka Lai; Atan, Ixora Kamisan; Dietz, Hans Peter
The aim of this study was to correlate clinical findings of anal sphincter defects and function with a sonographic diagnosis of significant sphincter defects. This is an observational cross-sectional study on women seen 6 to 10 weeks after primary repair of obstetric anal sphincter injuries (OASIs). All patients underwent a standardized interview including the St Mark incontinence score, a digital rectal examination, and 3-/4-dimensional transperineal ultrasound imaging. Two hundred forty-five patients were seen after primary repair of OASIs. Mean age was 29 (17-43) years. They were assessed at a median of 58 (15-278) days postpartum. One hundred fifty-seven (64%) delivered normal vaginally, 72 (29%) delivered by vacuum, and 16 (7%) delivered by forceps. A comparison of external anal sphincter (EAS) and internal anal sphincter ultrasound volume data and palpation was possible in 220 and 212 cases, respectively. Sphincter defects at rest and on contraction were both detected clinically in 17 patients. Significant abnormalities of the EAS were diagnosed on tomographic ultrasound imaging in 99 cases (45%), and significant abnormalities of the internal anal sphincter were diagnosed in 113 cases (53%). Agreement between digital and sonographic findings of sphincter defect was poor (k = 0.03-0.08). Women with significant EAS defects on ultrasound were found to have a lower resistance to digital insertion (P = 0.018) and maximum anal squeeze (P = 0.009) on a 6-point scale. The difference was however small. Digital rectal examination does not seem to be sufficiently sensitive to diagnose residual sphincter defects after primary repair of OASIs. Imaging is required for the evaluation of sphincter anatomy after repair.
2015-01-01
Objective Irreversible electroporation (IRE) of stage 3 pancreatic adenocarcinoma has been used to provide quality of life time in patients who have undergone appropriate induction therapy. The optimal technique has been reported within the literature, but not in video form. IRE of locally advanced pancreatic cancer is technically demanding requiring precision ultrasound use for continuous imaging in multiple needle placements and during IRE energy delivery. Methods Appropriate patients with locally advanced pancreatic cancer should have undergone appropriate induction chemotherapy for a reasonable duration. The safe and effective technique for irreversible electroporation is preformed through an open approach with the emphasis on intra-operative ultrasound and intra-operative electroporation management. Results The technique of open irreversible electroporation of the pancreas involves bracketing the target tumor with IRE probes and any and all invaded vital structures including the celiac axis, superior mesenteric artery (SMA), superior mesenteric-portal vein, and bile duct with continuous intraoperative ultrasound imaging through a caudal to cranial approach. Optimal IRE delivery requires a change in amperage of at least 12 amps from baseline tissue conductivity in order to achieve technical success. Multiple pull-backs are necessary since the IRE ablation probe lengths are 1 cm and thus needed to achieve technical success along the caudal to cranial plane. Conclusions Irreversible electroporation in combination with multi-modality therapy for locally advanced pancreatic carcinoma is feasible for appropriate patients with locally advanced cancer. Technical demands are high and require the highest quality ultrasound for precise spacing measurements and optimal delivery to ensure adequate change in tissue resistance. PMID:29075594
Color Doppler ultrasound evaluation of testicular blood flow in stallions.
Pozor, M A; McDonnell, S M
2004-04-01
The objectives of this study were to evaluate the potential use of color Doppler ultrasound to characterize blood flow to the stallion testis, and to establish reference values for Doppler measures of blood flow in the testicular artery of the stallion. Both testes from each of 52 horses were examined using a pulsed-wave color Doppler ultrasound with a sector array 5/7.5 MHz transducer with a 1mm gate setting. Peak systolic velocity (PSV), end diastolic velocity (EDV), resistive index (RI), and pulsatility index (PI) of the testicular artery were measured in each of two locations, the convoluted aspect (spermatic cord) and the marginal aspect of the artery (on the epididymal edge of testis). We found that: (1) all measures were obtainable; (2) except for EDV, the majority of the measures were higher at the cord location than at the marginal aspect of the artery (P < 0.05); and (3) measures for left and right testes were similar (P > 0.10). Resulting measures from 41 of these stallions (82 testes) that appeared free of testicular pathology provide useful reference values for clinical evaluation. Evaluation of 11 cases with testicular pathology suggested further investigation of possible effects of these various conditions on testicular blood flow and testicular function.
Some aspects of using ultrasounds to improve sulfurous mineral flotation technology
NASA Technical Reports Server (NTRS)
Mihu, V. P.; Pop, I.
1974-01-01
The results are discussed which were obtained with a new method of desorption of collector reagents connected with improving the selectivity of the flotation of copper and lead concentrate through the action of ultrasounds. Analysis of the results obtained by treating copper and lead concentrate in an ultraacoustic field indicates an increase in the copper content of the copper concentrate, of the lead content in the lead concentrate and, at the same time, a reduction in the lead of the copper concentrate.
4D ultrasound imaging - ethically justifiable in India?
Indiran, Venkatraman
2017-01-01
Four-dimensional (4D) ultrasound (real-time volume sonography), which has been used in the West since the last decade for the determination of gender as well as for bonding and entertainment of the parents, has become widely available in India in this decade. Here, I would like to discuss the ethical issues associated with 4D ultrasonography in India. These are self-referral, the use of the technology for non-medical indications, a higher possibility of the disclosure of the foetus' gender and safety concerns.
Mocny, Grzegorz; Bachul, Piotr; Chang, Ea-Sle; Kulig, Piotr
The aim of this study was to assess the predictive value of blood flow velocity and vascular resistance measured by Doppler ultrasound in terms of pulsatility index (PI) and resistive index (RI) respectively, in the occurrence of delayed graft function (DGF) after kidney transplantation. This prospective study enrolled kidney transplant recipients operated from January 2005 to April 2009 in the 1st Department of General, Oncological and Gastroenterological Surgery, Jagiellonian University Medical College, Kraków, Poland. The medical records of 53 kidney transplant recipients from deceased donors were reviewed. PI and RI values of the graft arcuate artery were calculated immediately after blood flow restoration and on the 1st, 2nd, 4th and 8th post-operative day. DGF was observed in 20 patients (37.7%), while 33 patients (62.3%) had immediate restoration of the kidney function. The mean intraoperative values of RI and PI from patients with DGF were significantly higher in comparison to patients without DGF (0.9 vs. 0.74, p <0.001; 1.76 vs. 1.54, p = 0.019, respectively). Post-operatively, the RI and PI values remained stable and significantly higher in DGF group. The highest sensitivity of RI to predict DGF occurrence was observed intraoperatively and on the first postoperative day, with values of 77.8% and 72.2%, respectively. The risk of DGF occurrence with intraoperative RI value ≥0.9 increased by 13-fold, and with intraoperative PI value ≥1.9 by 12-fold. This increase was even more prominent during the first post-operative day with RI value ≥0.9 or PI value ≥1.9 with 19-fold increase in the risk of DGF occurrence. According to our study, the utilization of Doppler ultrasound with measurement of hemodynamic parameters (PI, RI), play a crucial role in predicting the outcomes of kidney transplantation.
Physical rehabilitation of the canine neurologic patient.
Drum, Marti G
2010-01-01
Rehabilitation therapy is a key component of recovery from neurologic disease. Each patient requires a rehabilitation protocol designed specifically for the patient's neurologic condition, owner expectations and level of participation, and expertise of the veterinary team. Initial therapy for nonambualtory patients may include standing exercises, range of motion, pain control, toe pinch exercise, aquatic exercise, and basic nursing care. Sling assisted walking with foot protection, cavaletti rails, and physioroll balancing are used commonly for ambulatory patients. As recovery progresses, stair climbing, carrying or pulling weights, resistance band walking, swimming against resistance, and exercises specific to the home environment are added. Modalities such as electrical stimulation, ultrasound, cryotherapy, and heat therapy are useful adjuncts but do not take the place of active exercise.
Burgos, Carmen Mesas; Davey, Marcus G; Riley, John S; Jia, Huimin; Flake, Alan W; Peranteau, William H
2017-12-19
Lung and pulmonary vascular maldevelopment in congenital diaphragmatic hernia (CDH) results in significant morbidity and mortality. Retinoic acid (RA) and imatinib have been shown to improve pulmonary morphology following prenatal administration in the rat nitrofen-induced CDH model. It remains unclear if these changes translate into improved function. We evaluated the effect of prenatal RA and imatinib on postnatal lung function, structure, and pulmonary artery (PA) blood flow in the rat CDH model. Olive oil or nitrofen was administered alone or in combination with RA or imatinib to pregnant rats. Pups were assessed for PA blood flow by ultrasound and pulmonary function/morphology following delivery, intubation, and short-term ventilation. Neither RA nor imatinib had a negative effect on lung and body growth. RA accelerated lung maturation indicated by increased alveoli number and thinner interalveolar septa and was associated with decreased PA resistance and improved oxygenation. With the exception of a decreased PA pulsatility index, no significant changes in morphology and pulmonary function were noted following imatinib. Prenatal treatment with RA but not imatinib was associated with improved pulmonary morphology and function, and decreased pulmonary vascular resistance. This study highlights the potential of prenatal pharmacologic therapies, such as RA, for management of CDH. Copyright © 2017 Elsevier Inc. All rights reserved.
Xing, Wanjia; Liu, Xiaohong; He, Qingqing; Zhang, Zongjing; Jiang, Zhaoshun
2017-01-01
Resistance to thyroid hormone (RTH) is a rare autosomal hereditary disorder characterized by increased serum thyroid hormone (TH) levels with unsuppressed or increased thyrotropin concentration. It remains unknown whether the coexistence of RTH with papillary thyroid carcinoma (PTC) and Hashimoto thyroiditis (HT) is incidental or whether it possesses a genetic or pathophysiological association. In the present study, a case of RTH with PTC and HT in an 11-year-old Chinese patient was examined and the clinical presentation of RTH with PTC was discussed. In addition, the possible associations between RTH, PTC and HT were determined. HT was confirmed in the patient using an autoimmune assay and thyroid ultrasound. RTH was diagnosed on the basis of clinical manifestations, laboratory information and gene analysis, and PTC was diagnosed according to histological results. Results of BRAFV600E mutation analysis were positive. A literature review of 14 cases of RTH with PTC was included for comparison. The present case report indicates an association of RTH with PTC and HT coexistence in the patient. Close follow-up, histological evaluation and BRAFV600E mutation detection should be performed in each RTH case with HT, since a persistent increase in TSH may be a risk factor for the development of thyroid neoplasm. PMID:28928829
Xing, Wanjia; Liu, Xiaohong; He, Qingqing; Zhang, Zongjing; Jiang, Zhaoshun
2017-09-01
Resistance to thyroid hormone (RTH) is a rare autosomal hereditary disorder characterized by increased serum thyroid hormone (TH) levels with unsuppressed or increased thyrotropin concentration. It remains unknown whether the coexistence of RTH with papillary thyroid carcinoma (PTC) and Hashimoto thyroiditis (HT) is incidental or whether it possesses a genetic or pathophysiological association. In the present study, a case of RTH with PTC and HT in an 11-year-old Chinese patient was examined and the clinical presentation of RTH with PTC was discussed. In addition, the possible associations between RTH, PTC and HT were determined. HT was confirmed in the patient using an autoimmune assay and thyroid ultrasound. RTH was diagnosed on the basis of clinical manifestations, laboratory information and gene analysis, and PTC was diagnosed according to histological results. Results of BRAF V600E mutation analysis were positive. A literature review of 14 cases of RTH with PTC was included for comparison. The present case report indicates an association of RTH with PTC and HT coexistence in the patient. Close follow-up, histological evaluation and BRAF V600E mutation detection should be performed in each RTH case with HT, since a persistent increase in TSH may be a risk factor for the development of thyroid neoplasm.
Vaginal foreign body causing recurrent discharge and vaginal stenosis--a case report.
Gurung, Geeta; Rana, Ashma; Amatya, Archana
2007-06-01
Chronic vaginal discharge in children and adolescents is a common gynaecological complaint which is often resistant to antibiotic treatment. We present a 14 years old, premenarcheal girl who presented to us with the complaints of recurrent, foul smelling purulent occasionally blood stained vaginal discharge for eight years, where a foreign body in the upper vagina was found after releasing a dense adhesion of the lower vagina which was unable to detect by pelvic ultrasound.
Novel Image-Guided Management of a Uterine Arteriovenous Malformation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Przybojewski, Stefan J., E-mail: drstefanp@hotmail.com; Sadler, David J.
The investigators present a novel image-guided embolization, not previously described, of a uterine arteriovenous malformation (AVM) resistant to endovascular management. The uterus was exposed surgically, and Histoacryl (Braun, Fulda, Germany) was injected directly into the nidus using ultrasound guidance and fluoroscopy. The patient had a successful full-term pregnancy after this procedure. This technique may be a useful alternative management strategy in patients with uterine AVM who fail traditional endovascular embolization and who still desire fertility.
The effect of lipid monolayer in-plane rigidity on in vivo microbubble circulation persistence
Garg, Sumit; Thomas, Alex A.; Borden, Mark A.
2013-01-01
The goal of this study was to increase in vivo microbubble circulation persistence for applications in medical imaging and targeted drug delivery. Our approach was to investigate the effect of lipid monolayer in-plane rigidity to reduce the rate of microbubble dissolution, while holding constant the microbubble size, concentration and surface architecture. We first estimated the impact of acyl chain length of the main diacyl phosphatidyl-choline (PC) lipid and inter-lipid distance on the cohesive surface energy and, based on these results, we hypothesized that microbubble stability and in vivo ultrasound contrast persistence would increase monotonically with increasing acyl chain length. We therefore measured microbubble in vitro stability to dilution with and without ultrasound exposure, as well as in vivo ultrasound contrast persistence. All measurements showed a sharp rise in stability between DPPC (C16:0) and DSPC (C18:0), which correlates to the wrinkling transition, which signals the onset of significant surface shear and gas permeation resistance, observed in prior single-bubble dissolution studies. Further evidence for the effect of the wrinkling transition came from an in vitro and in vivo stability comparison of microbubbles coated with pure DPPC with those of lung surfactant extract. Microbubble stability against dilution without ultrasound and in vivo ultrasound contrast persistence showed a monotonic increase with acyl chain length from DSPC to DBPC (C22:0). However, we also observed that stability dropped precipitously for all measurements on further increasing lipid acyl chain length from DBPC to DLiPC (C24:0). This result suggests that hydrophobic mismatch between the main PC lipid and the lipopolymer emulsifier, DSPE-PEG5000, may drive a less stable surface microstructure. Overall, these results support our general hypothesis of the role of in-plane rigidity for increasing the lifetime of microbubble circulation. PMID:23787108
NASA Astrophysics Data System (ADS)
Simchen, F.; Rymer, L.-M.; Sieber, M.; Lampke, T.
2017-03-01
Magnesium and its alloys are increasingly in use as lightweight construction materials. However, their inappropriate corrosion and wear resistance often prevent their direct practical use. The plasma electrolytic oxidation (PEO) is a promising, environmentally friendly method to improve the surface characteristics of magnesium materials by the formation of oxide coatings. These PEO layers contain components of the applied electrolyte and can be shifted in their composition by increasing the concentration of the electrolyte constituents. Therefore, in contrast to the use of conventional low concentrated electrolytes, the process results in more stable protective coatings, in which electrolyte species are the dominating constitutes. In the present work, the influence of the composition of highly concentrated alkaline silicate electrolytes with additives of phosphate and glycerol on the quality of PEO layers on the magnesium alloy AZ31 was examined. The effect of ultrasound coupled into the electrolyte bath was also considered. The process was monitored by recording the electrical process variables with a transient recorder and by observation of the discharge phenomena on the sample surface with a camera. The study was conducted on the basis of a design of experiments. The effects of the process parameter variation are considered with regard to the coatings thickness, hardness and corrosion resistance. Information about the statistical significance of the effects of the parameters on the considered properties is obtained by an analysis of variance (ANOVA).
NASA Astrophysics Data System (ADS)
Cho, Hongseok; Lee, Hwa-Youn; Han, Mun; Choi, Jong-Ryul; Ahn, Sanghyun; Lee, Taekwan; Chang, Yongmin; Park, Juyoung
2016-08-01
Multi-drug resistant efflux transporters found in Blood-Brain Barrier (BBB) acts as a functional barrier, by pumping out most of the drugs into the blood. Previous studies showed focused ultrasound (FUS) induced microbubble oscillation can disrupt the BBB by loosening the tight junctions in the brain endothelial cells; however, no study was performed to investigate its impact on the functional barrier of the BBB. In this study, the BBB in rat brains were disrupted using the MRI guided FUS and microbubbles. The immunofluorescence study evaluated the expression of the P-glycoprotein (P-gp), the most dominant multi-drug resistant protein found in the BBB. Intensity of the P-gp expression at the BBB disruption (BBBD) regions was significantly reduced (63.2 ± 18.4%) compared to the control area. The magnitude of the BBBD and the level of the P-gp down-regulation were significantly correlated. Both the immunofluorescence and histologic analysis at the BBBD regions revealed no apparent damage in the brain endothelial cells. The results demonstrate that the FUS and microbubbles can induce a localized down-regulation of P-gp expression in rat brain. The study suggests a clinically translation of this method to treat neural diseases through targeted delivery of the wide ranges of brain disorder related drugs.
Huisman, Merel; Staruch, Robert M.; Ladouceur-Wodzak, Michelle; van den Bosch, Maurice A.; Burns, Dennis K.; Chhabra, Avneesh; Chopra, Rajiv
2015-01-01
Purpose Ultrasound (US)-guided high intensity focused ultrasound (HIFU) has been proposed for noninvasive treatment of neuropathic pain and has been investigated in in-vivo studies. However, ultrasound has important limitations regarding treatment guidance and temperature monitoring. Magnetic resonance (MR)-imaging guidance may overcome these limitations and MR-guided HIFU (MR-HIFU) has been used successfully for other clinical indications. The primary purpose of this study was to evaluate the feasibility of utilizing 3D MR neurography to identify and guide ablation of peripheral nerves using a clinical MR-HIFU system. Methods Volumetric MR-HIFU was used to induce lesions in the peripheral nerves of the lower limbs in three pigs. Diffusion-prep MR neurography and T1-weighted images were utilized to identify the target, plan treatment and immediate post-treatment evaluation. For each treatment, one 8 or 12 mm diameter treatment cell was used (sonication duration 20 s and 36 s, power 160–300 W). Peripheral nerves were extracted < 3 hours after treatment. Ablation dimensions were calculated from thermal maps, post-contrast MRI and macroscopy. Histological analysis included standard H&E staining, Masson’s trichrome and toluidine blue staining. Results All targeted peripheral nerves were identifiable on MR neurography and T1-weighted images and could be accurately ablated with a single exposure of focused ultrasound, with peak temperatures of 60.3 to 85.7°C. The lesion dimensions as measured on MR neurography were similar to the lesion dimensions as measured on CE-T1, thermal dose maps, and macroscopy. Histology indicated major hyperacute peripheral nerve damage, mostly confined to the location targeted for ablation. Conclusion Our preliminary results indicate that targeted peripheral nerve ablation is feasible with MR-HIFU. Diffusion-prep 3D MR neurography has potential for guiding therapy procedures where either nerve targeting or avoidance is desired, and may also have potential for post-treatment verification of thermal lesions without contrast injection. PMID:26659073
Yuan, Zhuang; Chen, Zhen-hua; Chen, Ding; Kang, Zhi-tao
2015-01-01
Ball milling experiments were conducted with and without ultrasound wave assistance in deionized water using NiCO3·2Ni(OH)2·4H2O as raw materials. In the reaction process of NiFe2O4 prepared by ultrasound-assisted aqueous solution ball milling, some influencing factors including raw materials, ultrasonic frequency, ball to powder ratio and liquid level were changed. Samples were characterized by X-ray diffraction, fluorescence measurements and electroconductivity detections. The results indicate that more hydroxyl radicals and ions can be generated under the coupling effect of ultrasonic and ball milling. The fluorescence measurements and electroconductivity detections also reflect the reaction speed, allowing for optimal parameters to be determined. Copyright © 2014 Elsevier B.V. All rights reserved.
PVT Degradation Studies: Acoustic Diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dib, Gerges; Tucker, Brian J.; Kouzes, Richard T.
Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regionsmore » with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.« less
[Research on Shielding of Emboli with the Phase-Controlled Ultrasound].
Liu, Chuang; Bai, Jingfeng
2016-01-01
The postoperative neurological complications is associated with intraoperative cerebral emboli, which results from extracorporeal circulation and operation. It can effectively reduce the incidence of neurological complications with ultrasonic radiation. In fluids, a particle will change it's motion trail when it is acted by the radiation force generated by the ultrasound. This article mainly discuss how to shielding emboli with ultrasound. The equipment can transmit phased ultrasonic signals, which is designed on a FPGA development board. The board can generate a square wave, which is converted into a sine wave through a power amplifier. In addition, the control software has been developed on Qt development environment. The result indicates it's feasible to shielding emboli with ultrasonic radiation force. This article builds a strong foundation for the future research.
NASA Astrophysics Data System (ADS)
Meshram, N. H.; Varghese, T.; Mitchell, C. C.; Jackson, D. C.; Wilbrand, S. M.; Hermann, B. P.; Dempsey, R. J.
2017-08-01
Vulnerability and instability in carotid artery plaque has been assessed based on strain variations using noninvasive ultrasound imaging. We previously demonstrated that carotid plaques with higher strain indices in a region of interest (ROI) correlated to patients with lower cognition, probably due to cerebrovascular emboli arising from these unstable plaques. This work attempts to characterize the strain distribution throughout the entire plaque region instead of being restricted to a single localized ROI. Multiple ROIs are selected within the entire plaque region, based on thresholds determined by the maximum and average strains in the entire plaque, enabling generation of additional relevant strain indices. Ultrasound strain imaging of carotid plaques, was performed on 60 human patients using an 18L6 transducer coupled to a Siemens Acuson S2000 system to acquire radiofrequency data over several cardiac cycles. Patients also underwent a battery of neuropsychological tests under a protocol based on National Institute of Neurological Disorders and Stroke and Canadian Stroke Network guidelines. Correlation of strain indices with composite cognitive index of executive function revealed a negative association relating high strain to poor cognition. Patients grouped into high and low cognition groups were then classified using these additional strain indices. One of our newer indices, namely the average L - 1 norm with plaque (AL1NWP) presented with significantly improved correlation with executive function when compared to our previously reported maximum accumulated strain indices. An optimal combination of three of the new indices generated classifiers of patient cognition with an area under the curve (AUC) of 0.880, 0.921 and 0.905 for all (n = 60), symptomatic (n = 33) and asymptomatic patients (n = 27) whereas classifiers using maximum accumulated strain indices alone provided AUC values of 0.817, 0.815 and 0.813 respectively.
Meshram, N H; Varghese, T; Mitchell, C C; Jackson, D C; Wilbrand, S M; Hermann, B P; Dempsey, R J
2017-07-17
Vulnerability and instability in carotid artery plaque has been assessed based on strain variations using noninvasive ultrasound imaging. We previously demonstrated that carotid plaques with higher strain indices in a region of interest (ROI) correlated to patients with lower cognition, probably due to cerebrovascular emboli arising from these unstable plaques. This work attempts to characterize the strain distribution throughout the entire plaque region instead of being restricted to a single localized ROI. Multiple ROIs are selected within the entire plaque region, based on thresholds determined by the maximum and average strains in the entire plaque, enabling generation of additional relevant strain indices. Ultrasound strain imaging of carotid plaques, was performed on 60 human patients using an 18L6 transducer coupled to a Siemens Acuson S2000 system to acquire radiofrequency data over several cardiac cycles. Patients also underwent a battery of neuropsychological tests under a protocol based on National Institute of Neurological Disorders and Stroke and Canadian Stroke Network guidelines. Correlation of strain indices with composite cognitive index of executive function revealed a negative association relating high strain to poor cognition. Patients grouped into high and low cognition groups were then classified using these additional strain indices. One of our newer indices, namely the average L - 1 norm with plaque (AL1NWP) presented with significantly improved correlation with executive function when compared to our previously reported maximum accumulated strain indices. An optimal combination of three of the new indices generated classifiers of patient cognition with an area under the curve (AUC) of 0.880, 0.921 and 0.905 for all (n = 60), symptomatic (n = 33) and asymptomatic patients (n = 27) whereas classifiers using maximum accumulated strain indices alone provided AUC values of 0.817, 0.815 and 0.813 respectively.
Jin, Jian; Ma, Haile; Qu, Wenjuan; Wang, Kai; Zhou, Cunshan; He, Ronghai; Luo, Lin; Owusu, John
2015-11-01
The effects of multi-frequency power ultrasound (MPU) pretreatment on the kinetics and thermodynamics of corn gluten meal (CGM) were investigated in this research. The apparent constant (KM), apparent break-down rate constant (kA), reaction rate constants (k), energy of activation (Ea), enthalpy of activation (ΔH), entropy of activation (ΔS) and Gibbs free energy of activation (ΔG) were determined by means of the Michaelis-Menten equation, first-order kinetics model, Arrhenius equation and transition state theory, respectively. The results showed that MPU pretreatment can accelerate the enzymolysis of CGM under different enzymolysis conditions, viz. substrate concentration, enzyme concentration, pH, and temperature. Kinetics analysis revealed that MPU pretreatment decreased the KM value by 26.1% and increased the kA value by 7.3%, indicating ultrasound pretreatment increased the affinity between enzyme and substrate. In addition, the values of k for ultrasound pretreatment were increased by 84.8%, 41.9%, 28.9%, and 18.8% at the temperature of 293, 303, 313 and 323 K, respectively. For the thermodynamic parameters, ultrasound decreased Ea, ΔH and ΔS by 23.0%, 24.3% and 25.3%, respectively, but ultrasound had little change in ΔG value in the temperature range of 293-323 K. In conclusion, MPU pretreatment could remarkably enhance the enzymolysis of CGM, and this method can be applied to protein proteolysis industry to produce peptides. Copyright © 2015 Elsevier B.V. All rights reserved.
Miyamoto, Naokazu; Hirata, Kosuke; Kanehisa, Hiroaki; Yoshitake, Yasuhide
2015-01-01
Ultrasound shear wave elastography is becoming a valuable tool for measuring mechanical properties of individual muscles. Since ultrasound shear wave elastography measures shear modulus along the principal axis of the probe (i.e., along the transverse axis of the imaging plane), the measured shear modulus most accurately represents the mechanical property of the muscle along the fascicle direction when the probe's principal axis is parallel to the fascicle direction in the plane of the ultrasound image. However, it is unclear how the measured shear modulus is affected by the probe angle relative to the fascicle direction in the same plane. The purpose of the present study was therefore to examine whether the angle between the principal axis of the probe and the fascicle direction in the same plane affects the measured shear modulus. Shear modulus in seven specially-designed tissue-mimicking phantoms, and in eleven human in-vivo biceps brachii and medial gastrocnemius were determined by using ultrasound shear wave elastography. The probe was positioned parallel or 20° obliquely to the fascicle across the B-mode images. The reproducibility of shear modulus measurements was high for both parallel and oblique conditions. Although there was a significant effect of the probe angle relative to the fascicle on the shear modulus in human experiment, the magnitude was negligibly small. These findings indicate that the ultrasound shear wave elastography is a valid tool for evaluating the mechanical property of pennate muscles along the fascicle direction.
Saliev, Timur; Feril, Loreto B.; Ogawa, Koichi; Watanabe, Akiko; Begimbetova, Dinara; Molkenov, Askhat; Alimbetov, Dauren; Tachibana, Katsuro
2016-01-01
Background We scrutinized the feasibility of apoptosis induction in blood cancer cells by means of low-intensity ultrasound and the proteasome inhibitor bortezomib (Velcade). Material/Methods Human leukemic monocyte lymphoma U937 cells were subjected to ultrasound in the presence of bortezomib and the echo contrast agent Sonazoid. Two types of acoustic intensity (0.18 W/cm2 and 0.05 W/cm2) were used for the experiments. Treated U937 cells were analyzed for viability and levels of early and late apoptosis. In addition, scanning electron microscopy analysis of treated cells was performed. Results The percentage of cells that underwent early apoptosis in the group treated with ultrasound and Sonazoid was 8.0±1.31% (intensity 0.18 W/cm2) and 7.0±1.69% (0.05 W/cm2). However, coupling of bortezomib and Sonazoid resulted in an increase in the percentage of cells in the early apoptosis phase, up to 32.50±3.59% (intensity 0.18 W/cm2) and 33.0±4.90% (0.05 W/cm2). The percentage of U937 cells in the late apoptosis stage was not significantly different from that in the group treated with bortezomib only. Conclusions Our findings indicate the feasibility of apoptosis induction in blood cancer cells by using a combination of bortezomib, ultrasound contrast agents, and low-intensity ultrasound. PMID:28003640
Nomikou, N; Feichtinger, G A; Saha, S; Nuernberger, S; Heimel, P; Redl, H; McHale, A P
2018-01-01
Gene-activated matrix (GAM)-based therapeutics for tissue regeneration are limited by efficacy, the lack of spatiotemporal control and availability of target cells, all of which impact negatively on their translation to the clinic. Here, an advanced ultrasound-responsive GAM is described containing target cells that facilitates matrix-assisted sonoporation (MAS) to induce osteogenic differentiation. Ultrasound-responsive GAMs consisting of fibrin/collagen hybrid-matrices containing microbubbles, bone morphogenetic protein BMP2/7 coexpression plasmids together with C2C12 cells were treated with ultrasound either in vitro or following parenteral intramuscular implantation in vivo. Using direct measurement for alkaline phosphatase activity, von Kossa staining and immunohistochemical analysis for osteocalcin expression, MAS-stimulated osteogenic differentiation was confirmed in the GAMs in vitro 7 days after treatment with ultrasound. At day 30 post-treatment with ultrasound, ectopic osteogenic differentiation was confirmed in vivo using X-ray microcomputed tomography and histological analysis. Osteogenic differentiation was indicated by the presence of ectopic bone structures in all animals treated with MAS. In addition, bone volumes in this group were statistically greater than those in the control groups. This novel approach of incorporating a MAS capability into GAMs could be exploited to facilitate ex vivo gene transfer with subsequent surgical implantation or alternatively provide a minimally invasive means of stimulating in situ transgene delivery for osteoinductive gene-based therapies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Miller, Douglas L.
2016-01-01
Diagnostic ultrasound can induce pulmonary capillary hemorrhage (PCH) in rats and other mammals. This phenomenon represents the only clearly demonstrated biological effect of (non-contrast enhanced) diagnostic ultrasound and thus presents a uniquely important safety issue. However, the physical mechanism responsible for PCH remains uncertain more than 25 y after its discovery. Experimental research has indicated that neither heating nor acoustic cavitation, the predominant mechanisms for bioeffects of ultrasound, is responsible for PCH. Furthermore, proposed theoretical mechanisms based on gas body activation, on alveolar resonance and on impulsive generation of liquid droplets all appear unlikely to be responsible for PCH, owing to unrealistic model assumptions. Here, a simple model based on the acoustic radiation surface pressure (ARSP) at a tissue-air interface is hypothesized as the mechanism for PCH. The ARSP model seems to explain some features of PCH, including the approximate frequency independence of PCH thresholds, and the dependence of thresholds on biological factors. However, ARSP evaluated for experimental threshold conditions appear to be too weak to fully account for stress failure of pulmonary capillaries, gauging by known stresses for injurious physiological conditions. Furthermore, consideration of bulk properties of lung tissue suggests substantial transmission of ultrasound through the pleura, with reduced ARSP and potential involvement of additional mechanisms within the pulmonary interior. Although these recent findings advance our knowledge, only a full understanding of PCH mechanisms will allow development of science-based safety assurance for pulmonary ultrasound. PMID:27649878
Diffuse vascular damage in a transplanted kidney: an indication for nuclear magnetic resonance?
Burdese, M; Consiglio, V; Mezza, E; Savio, D; Guarena, C; Rossetti, M; Messina, M; Soragna, G; Suriani, C; Rabbia, C; Segoloni, G P; Piccoli, G B
2005-06-01
Vascular lesions are an increasing challenge after renal transplantation due to the wider indications for recipients and acceptance criteria for donors. Diagnostic approach and prognostic interpretation are still matter of controversy. The case reported herein may summarize some of the issues in this regard. A 54-year-old woman, on renal replacement therapy since 1974, and a kidney graft recipient from 1975 to 1999, received a second graft in 2001. The donor age was 65 years (cold ischemia 22 hours; two mismatches). The early posttransplant follow-up was characterized by delayed graft function, hypertension, and diabetes. During the initial hypertension workup, renal graft ultrasound (US) Doppler demonstrated increased vascular resistances, stable over time (resistance index 0.74 to 0.77); renal scintiscan displayed homogeneously parenchymoa and angio-magnetic resonance imaging (MRI), an homogeneous parenchymal vascularization. Initial immunosuppression with tacrolimus and steroids was modulated by adding mycophenolate mofetil to taper tacrolimus (to reduce nephrotoxicity and hypertension). Despite this, kidney function slowly deteriorated; serum creatinine reached 3 to 3.5 mg/dL by the second year. After a severe hypertensive crisis with unchanged scintiscan and US doppler examinations, angio-MRI revealed the almost complete disappearance of parenchymal enhancement beyond the lobar arteries. A renal biopsy confirmed the severe vascular damage. The patient was switched to rapamycine and a low-dose of an angiotension converting enzyme (ACE) inhibitor. She did relatively well (serum creatinine 2.2 to 3 mg/dL) for 6 months, when rapid functional impairment forced her to restart hemodialysis. This case, almost paradigmatic of the problems occurring when the rigid vasculature of long-term dialysis patients is matched with "marginal kidneys," suggests that MRI may be a sensible good to define vascular damage in the grafted kidney.
Lipid shedding from single oscillating microbubbles.
Luan, Ying; Lajoinie, Guillaume; Gelderblom, Erik; Skachkov, Ilya; van der Steen, Antonius F W; Vos, Hendrik J; Versluis, Michel; De Jong, Nico
2014-08-01
Lipid-coated microbubbles are used clinically as contrast agents for ultrasound imaging and are being developed for a variety of therapeutic applications. The lipid encapsulation and shedding of the lipids by acoustic driving of the microbubble has a crucial role in microbubble stability and in ultrasound-triggered drug delivery; however, little is known about the dynamics of lipid shedding under ultrasound excitation. Here we describe a study that optically characterized the lipid shedding behavior of individual microbubbles on a time scale of nanoseconds to microseconds. A single ultrasound burst of 20 to 1000 cycles, with a frequency of 1 MHz and an acoustic pressure varying from 50 to 425 kPa, was applied. In the first step, high-speed fluorescence imaging was performed at 150,000 frames per second to capture the instantaneous dynamics of lipid shedding. Lipid detachment was observed within the first few cycles of ultrasound. Subsequently, the detached lipids were transported by the surrounding flow field, either parallel to the focal plane (in-plane shedding) or in a trajectory perpendicular to the focal plane (out-of-plane shedding). In the second step, the onset of lipid shedding was studied as a function of the acoustic driving parameters, for example, pressure, number of cycles, bubble size and oscillation amplitude. The latter was recorded with an ultrafast framing camera running at 10 million frames per second. A threshold for lipid shedding under ultrasound excitation was found for a relative bubble oscillation amplitude >30%. Lipid shedding was found to be reproducible, indicating that the shedding event can be controlled. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Ghodbane, Houria; Hamdaoui, Oualid
2009-06-01
In this work, the sonolytic degradation of an anthraquinonic dye, C.I. Acid Blue 25 (AB25), in aqueous phase using high frequency ultrasound waves (1700kHz) for an acoustic power of 14W was investigated. The sonochemical efficiency of the reactor was evaluated by potassium iodide dosimeter, Fricke reaction and hydrogen peroxide production yield. The three investigated methods clearly show the production of oxidizing species during sonication and well reflect the sonochemical effects of high frequency ultrasonic irradiation. The effect of operational conditions such as the initial AB25 concentration, solution temperature and pH on the degradation of AB25 was studied. Additionally, the influence of addition of salts on the degradation of dye was examined. The rate of AB25 degradation was dependent on initial dye concentration, pH and temperature. Addition of salts increased the degradation of dye. Experiments conducted using distilled and natural waters demonstrated that the degradation was more efficient in the natural water compared to distilled water. To increase the efficiency of AB25 degradation, experiments combining ultrasound with Fe(II) or H(2)O(2) were conducted. Fe(II) induced the dissociation of ultrasonically produced hydrogen peroxide, leading to additional OH radicals which enhance the degradation of dye. The combination of ultrasound with hydrogen peroxide looks to be a promising option to increase the generation of free radicals. The concentration of hydrogen peroxide plays a crucial role in deciding the extent of enhancement obtained for the combined process. The results of the present work indicate that ultrasound/H(2)O(2) and ultrasound/Fe(II) processes are efficient for the degradation of AB25 in aqueous solutions by high frequency ultrasonic irradiation.
Comparison of extraction methods for quantifying vitamin E from animal tissues.
Xu, Zhimin
2008-12-01
Four extraction methods: (1) solvent (SOL), (2) ultrasound assisted solvent (UA), (3) saponification and solvent (SP), and (4) saponification and ultrasound assisted solvent (SP-UA), were used in sample preparation for quantifying vitamin E (tocopherols) in chicken liver and plasma samples. The extraction yields of SOL, UA, SP, and SP-UA methods obtained by adding delta-tocopherol as internal reference were 95%, 104%, 65%, and 62% for liver and 98%, 103%, 97%, and 94% for plasma, respectively. The methods with saponification significantly affected the stabilities of tocopherols in liver samples. The measured values of alpha- and gamma-tocopherols using the solvent only extraction (SOL) method were much lower than that using any of the other extraction methods. This indicated that less of the tocopherols in those samples were in a form that could be extracted directly by solvent. The measured value of alpha-tocopherol in the liver sample using the ultrasound assisted solvent (UA) method was 1.5-2.5 times of that obtained from the saponification and solvent (SP) method. The differences in measured values of tocopherols in the plasma samples by using the two methods were not significant. However, the measured value of the saponification and ultrasound assisted solvent (SP-UA) method was lower than either the saponification and solvent (SP) or the ultrasound assisted solvent (UA) method. Also, the reproducibility of the ultrasound assisted solvent (UA) method was greater than any of the saponification methods. Compared with the traditional saponification method, the ultrasound assisted solvent method could effectively extract tocopherols from sample matrix without any chemical degradation reactions, especially for complex animal tissue such as liver.
Santana-Rodríguez, Norberto; Clavo, Bernardino; Fernández-Pérez, Leandro; Rivero, José C; Travieso, María M; Fiuza, María D; Villar, Jesús; García-Castellano, José M; Hernández-Pérez, Octavio; Déniz, Antonio
2011-05-01
Rib fractures are a frequent traumatic injury associated with a relatively high morbidity. Currently, the treatment of rib fractures is symptomatic. Since it has been reported that pulsed ultrasounds accelerates repair of limb fractures, we hypothesized that the application of pulsed ultrasounds will modify the course of healing in an animal model of rib fracture. We studied 136 male Sprague-Dawley rats. Animals were randomly assigned to different groups of doses (none, 50, 100, and 250 mW/cm(2) of intensity for 3 minutes per day) and durations (2, 10, 20, and 28 days) of treatment with pulsed ultrasounds. In every subgroup, we analyzed radiologic and histologic changes in the bone callus. In addition, we examined changes in gene expression of relevant genes involved in wound repair in both control and treated animals. Histologic and radiologic consolidation was significantly increased by pulsed ultrasound treatment when applied for more than 10 days. The application of 50 mW/cm(2) was the most effective dose. Only the 100 and 250 mW/cm(2) doses were able to significantly increase messenger RNA expression of insulin-like growth factor 1, suppressor of cytokine signaling-2 and -3, and vascular endothelial growth factor and decrease monocyte chemoattractant protein-1 and collagen type II-alpha 1. Our findings indicate that pulsed ultrasound accelerates the consolidation of rib fractures. This study is the first to show that pulsed ultrasound promotes the healing of rib fractures. From a translational point of view, this easy, cheap technique could serve as an effective new therapeutic modality in patients with rib fractures. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Sulaiman, Alifdalino; Farid, Mohammed; Silva, Filipa Vm
2017-06-01
Strawberry puree was processed for 15 min using thermal (65 ℃), high-pressure processing (600 MPa, 48 ℃), and ultrasound (24 kHz, 1.3 W/g, 33 ℃). These conditions were selected based on similar polyphenoloxidase inactivation (11%-18%). The specific energies required for the above-mentioned thermal, high-pressure processing, and power ultrasound processes were 240, 291, and 1233 kJ/kg, respectively. Then, the processed strawberry was stored at 3 ℃ and room temperature for 30 days. The constant pH (3.38±0.03) and soluble solids content (9.03 ± 0.25°Brix) during storage indicated a microbiological stability. Polyphenoloxidase did not reactivate during storage. The high-pressure processing and ultrasound treatments retained the antioxidant activity (70%-74%) better than the thermal process (60%), and high-pressure processing was the best treatment after 30 days of ambient storage to preserve antioxidant activity. Puree treated with ultrasound presented more color retention after processing and after ambient storage than the other preservation methods. For the three treatments, the changes of antioxidant activity and total color difference during storage were described by the fractional conversion model with rate constants k ranging between 0.03-0.09 and 0.06-0.22 day - 1 , respectively. In resume, high-pressure processing and thermal processes required much less energy than ultrasound for the same polyphenoloxidase inactivation in strawberry. While high-pressure processing retained better the antioxidant activity of the strawberry puree during storage, the ultrasound treatment was better in terms of color retention.
Spectrophotometer and ultrasound evaluation of late toxicity following breast-cancer radiotherapy.
Yoshida, E J; Chen, H; Torres, M A; Curran, W J; Liu, T
2011-10-01
Radiation-induced normal-tissue toxicities are common, complex, and distressing side effects that affect 90% of patients receiving breast-cancer radiotherapy and 40% of patients post radiotherapy. In this study, the authors investigated the use of spectrophotometry and ultrasound to quantitatively measure radiation-induced skin discoloration and subcutaneous-tissue fibrosis. The study's purpose is to determine whether skin discoloration correlates with the development of fibrosis in breast-cancer radiotherapy. Eighteen breast-cancer patients were enrolled in our initial study. All patients were previously treated with a standard course of radiation, and the median follow-up time was 22 months. The treated and untreated breasts were scanned with a spectrophotometer and an ultrasound. Two spectrophotometer parameters-melanin and erythema indices-were used to quantitatively assess skin discoloration. Two ultrasound parameters-skin thickness and Pearson coefficient of the hypodermis-were used to quantitatively assess severity of fibrosis. These measurements were correlated with clinical assessments (RTOG late morbidity scores). Significant measurement differences between the treated and contralateral breasts were observed among all patients: 27.3% mean increase in skin thickness (p < 0.001), 34.1% mean decrease in Pearson coefficient (p < 0.001), 27.3% mean increase in melanin (p < 0.001), and 22.6% mean increase in erythema (p < 0.001). All parameters except skin thickness correlated with RTOG scores. A moderate correlation exists between melanin and erythema; however, spectrophotometer parameters do not correlate with ultrasound parameters. Spectrophotometry and quantitative ultrasound are objective tools that assess radiation-induced tissue injury. Spectrophotometer parameters did not correlate with those of quantitative ultrasound suggesting that skin discoloration cannot be used as a marker for subcutaneous fibrosis. These tools may prove useful for the reduction of radiation morbidities and improvement of patient quality of life.
Hamarat, Mustafa Bilal; Tarhan, Fatih; Horuz, Rahim; Öcal, Gülfem Akengin; Demirkol, Mehmet Kutlu; Kafkaslı, Alper; Yazıcı, Özgür
2017-06-01
In the present study, we aimed to invastigate the ciprofloxacin resistance in rectal flora of the patients undergoing prostate biopsy in our department. Additionally, the possible effects of the presence of ciprofloxacin resistant bacteria in faecal flora on the risk of infective complications after the procedure as well as the effect of antibiotic prophylaxis on such infectious complications have been evaluated. A total of 142 patients undergoing transrectal ultrasound-guided prostate biopsy were included into the study program. Rectal swab samples were taken from all patients prior to biopsy. The presence of complications have been evaluated after a week following the biopsy procedure. Patients with fever were also evaluated. The possible correlation between the presence of ciprofloxacin-resistant bacteria in faecal flora and the risk of urinary tract infection development and the other complications were evaluated. E. coli bacteria were present in all cultures of rectal swab samples obtained from 142 patients prior to prostate biopsy. Of all these patients, while ciprofloxacin-resistant E. coli (CR E. coli ) grew in 76 (53.5%) patients; ciprofloxacin susceptible E. coli (CS E. coli ) was obtained in 66 (46.5%) patients. In 16 patients (11.3%), infectious complications were observed. While the infective complications were present in the 14.5% of patients with CR E. coli ; they were present in the 7.6% of patients with CS E. coli (p=0.295). High fever was observed in nine patients (6.3%). Of these nine patients, although six had CR E. coli growth as detected during culture sensitivity tests; three had CS E. coli growth in their rectal swab culture tests. Sepsis was observed in three (2.1%) of these patients with high fever. Ciprofloxacin-resistant E. coli grew in all of the rectal swab cultures obtained from these patients with sepsis. In the light of our findings we may say that, it will be appropriate to reconsider the ciprofloxacin prophylaxis and prefer to use other prophylactic agents for a certain period of time in populations with higher rates of resistance to this medical agent. Furthermore, it will be appropriate again to obtain rectal swab specimens for culture tests before biopsy procedure in order to perform targeted prophylaxis according to the culture antibiogram test results. This approach will enable us to evaluate the cost-effectiveness of the procedure in detail.
The effect of particle density on ultrasound-mediated transport of nanoparticles.
Lea-Banks, Harriet; Teo, Boon; Stride, Eleanor; Coussios, Constantin C
2016-11-21
A significant barrier to successful drug delivery is the limited penetration of nanoscale therapeutics beyond the vasculature. Building on recent in vivo findings in the context of cancer drug delivery, the current study investigates whether modification of nanoparticle drug-carriers to increase their density can be used to enhance their penetration into viscoelastic materials under ultrasound exposure. A computational model is first presented to predict the transport of identically sized nanoparticles of different densities in an ultrasonic field in the presence of an oscillating microbubble, by a combination of primary and secondary acoustic radiation forces, acoustic streaming and microstreaming. Experiments are then described in which near monodisperse (polydispersity index <0.2) nanoparticles of approximate mean diameter 200 nm and densities ranging from 1.01 g cm -3 to 5.58 g cm -3 were fabricated and delivered to a tissue-mimicking material in the presence or absence of a microbubble ultrasound contrast agent, at ultrasound frequencies of 0.5 MHz and 1.6 MHz and a peak negative pressure of 1 MPa. Both the theoretical and experimental results confirm that denser particles exhibit significantly greater ultrasound-mediated transport than their lower density counterparts, indicating that density is a key consideration in the design of nanoscale therapeutics.
Bipolar-power-transistor-based limiter for high frequency ultrasound imaging systems.
Choi, Hojong; Yang, Hao-Chung; Shung, K Kirk
2014-03-01
High performance limiters are described in this paper for applications in high frequency ultrasound imaging systems. Limiters protect the ultrasound receiver from the high voltage (HV) spikes produced by the transmitter. We present a new bipolar power transistor (BPT) configuration and compare its design and performance to a diode limiter used in traditional ultrasound research and one commercially available limiter. Limiter performance depends greatly on the insertion loss (IL), total harmonic distortion (THD) and response time (RT), each of which will be evaluated in all the limiters. The results indicated that, compared with commercial limiter, BPT-based limiter had less IL (-7.7 dB), THD (-74.6 dB) and lower RT (43 ns) at 100 MHz. To evaluate the capability of these limiters, they were connected to a 100 MHz single element transducer and a two-way pulse-echo test was performed. It was found that the -6 dB bandwidth and sensitivity of the transducer using BPT-based limiter were better than those of the commercial limiter by 22% and 140%, respectively. Compared to the commercial limiter, BPT-based limiter is shown to be capable of minimizing signal attenuation, RT and THD at high frequencies and is thus suited for high frequency ultrasound applications. Copyright © 2013 Elsevier B.V. All rights reserved.
Register cardiac fiber orientations from 3D DTI volume to 2D ultrasound image of rat hearts
NASA Astrophysics Data System (ADS)
Qin, Xulei; Wang, Silun; Shen, Ming; Zhang, Xiaodong; Lerakis, Stamatios; Wagner, Mary B.; Fei, Baowei
2015-03-01
Two-dimensional (2D) ultrasound or echocardiography is one of the most widely used examinations for the diagnosis of cardiac diseases. However, it only supplies the geometric and structural information of the myocardium. In order to supply more detailed microstructure information of the myocardium, this paper proposes a registration method to map cardiac fiber orientations from three-dimensional (3D) magnetic resonance diffusion tensor imaging (MR-DTI) volume to the 2D ultrasound image. It utilizes a 2D/3D intensity based registration procedure including rigid, log-demons, and affine transformations to search the best similar slice from the template volume. After registration, the cardiac fiber orientations are mapped to the 2D ultrasound image via fiber relocations and reorientations. This method was validated by six images of rat hearts ex vivo. The evaluation results indicated that the final Dice similarity coefficient (DSC) achieved more than 90% after geometric registrations; and the inclination angle errors (IAE) between the mapped fiber orientations and the gold standards were less than 15 degree. This method may provide a practical tool for cardiologists to examine cardiac fiber orientations on ultrasound images and have the potential to supply additional information for diagnosis of cardiac diseases.
Kim, Seungsoo; Chen, Yun-Sheng; Luke, Geoffrey P; Emelianov, Stanislav Y
2014-05-01
In nanoparticle-augmented photothermal therapy, evaluating the delivery and spatial distribution of nanoparticles, followed by remote temperature mapping and monitoring, is essential to ensure the optimal therapeutic outcome. The utility of ultrasound and photoacoustic imaging to assist photothermal therapy has been previously demonstrated. Here, using a mouse xenograft tumor model, it is demonstrated in vivo that ultrasound-guided photoacoustic imaging can be used to plan the treatment and to guide the therapy. To evaluate nanoparticle delivery and spatial distribution, three-dimensional ultrasound and spectroscopic photoacoustic imaging of a mouse with a tumor was performed before and after intravenous injection of silica-coated gold nanorods. After injection and sufficient circulation of nanoparticles, photothermal therapy was performed for 5 min using an 808-nm continuous-wave laser. During the photothermal therapy, photoacoustic images were acquired continuously and used to measure the temperature changes within tissue. A heterogeneous distribution of temperature, which was spatially correlated with the measured distribution of nanoparticles, indicated that peak temperatures of 53°C were achieved in the tumor. An Arrhenius thermal damage model determined that this thermal deposition would result in significant cell death. The results of this study suggest that ultrasound and photoacoustic imaging can effectively guide photothermal therapy to achieve the desired thermal treatment.
Ayim, Ishmael; Ma, Haile; Alenyorege, Evans Adingba; Ali, Zeshan; Donkor, Prince Ofori
2018-03-01
The effect of ultrasound pretreatment using Single Frequency Counter Current Ultrasound (SFCCU) on the enzymolysis of tea residue protein (TRP) extracted with sodium hydroxide was investigated. The concentration of TRP hydrolysate, enzymolysis kinetics and thermodynamic parameters after SFCCU pretreatment were determined and compared with traditional enzymolysis. The results indicated that both ultrasound assisted and traditional enzymolysis conformed to first-order kinetics within the limits of the studied parameters. Temperature and sonication had affirmative effect on the enzymolysis of TRP with temperature yielding greater impact. Michaelis constant ( K M ) in ultrasonic pretreated enzymolysis decreased by 32.7% over the traditional enzymolysis. The highest polypeptide concentration of 24.12 mg ml -1 was obtained with the lowest energy requirement at improved conditions of 50 g L -1 of TRP, alcalase concentration of 2000 U g -1 , time of 10 min and temperature of 50 °C for the ultrasonic treated enzymolysis. The values of reaction rate constant ( k ) for TRP enzymolysis increased by 78, 40, 82 and 60% at 20, 30, 40 and 50 °C, respectively. The thermodynamic properties comprising activation energy ( Ea ), change in enthalpy (∆H ) and entropy (∆S ) were reduced by ultrasound pretreatment whereas Gibbs free energy (∆G ) was increased.
Drug-Loaded Nanoemulsions/Microbubbles for Combined Tumor Imaging and Therapy
NASA Astrophysics Data System (ADS)
Rapoport, Natalya; Gao, Zhonggao; Kennedy, Ann
2007-05-01
A new class of multifunctional nanoparticles that combine properties of polymeric drug carriers, ultrasound imaging contrast agents, and enhancers of ultrasound-mediated intracellular drug delivery was developed. At room temperature, the developed systems comprise perfluorocarbon nanodroplets stabilized by the walls made of biodegradable block copolymers. The nanodroplets convert into microbubbles upon heating to physiological temperatures. The phase state of the systems and nanodroplet size may be controlled by the copolymer/perfluorocarbon volume ratio. Three areas observed in phase diagrams correspond to micelles; micelle/microbubble coexistence; and nano/microbubble coexistence. These systems manifest a relatively high drug loading capacity (about 15 % wt/wt). As indicated by biodistribution measurements and ultrasound imaging, the micelles and nanobubbles extravasate selectively into the tumor interstitia. Microbubble cavitate and collapse under the action of tumor-directed ultrasound, resulting in a dramatically enhanced intracellular drug uptake by the tumor cells. Upon intravenous injections, a long-lasting, strong and selective ultrasound contrast is observed in the tumor volume confirming nanobubble extravasation through the defected tumor microvasculature and suggesting their coalescence into larger, highly echogenic microbubbles in the tumor tissue. This effect is tumor-selective; no accumulation of echogenic microbubbles is observed in other organs. Tumor contrast increases in time confirming gradual accumulation of echogenic microbubbles in the tumor tissue, presumably via the enhanced penetration and retention (EPR) effect.
Wang, Sen; Li, Yu; Ji, Ying-Chang; Lin, Chang-Min; Man, Cheng; Zheng, Xiao-Xuan
2010-01-01
Although doctors try their best to protect transplants during surgery, there remain great challenges for the higher survival rate and less rejection of transplants after organ transplantation. Growing evidence indicates that the stem cells could function after injury rather than aging, implying that suitable injury may activate the stem cells of damaged organs. Furthermore, it has been revealed that stem cells can be used to induce tolerance in transplantation and the ultrasound has great biological effects on organs. Basing on these facts, we hypothesize that the stem cells within the transplants can be activated by ultrasound with high-frequency and medium-intensity. Therefore, the stem-cell-activated organs (SCAO) can be derived, and the SCAO will be better transplant option for organ transplantation. We postulate the ultrasound can change the molecular activity and/or quantity of the stem cells, the membrane permeability, the cell-cell junctions, and their surrounding microenvironments. As a result, the stem cells are activated, and the SCAO will acquire more regenerative capacity and less rejection. In the paper, we also discuss the process, methods and models for verifying the theory, and the consequences. We believe the theory may provide a practical method for the clinical application of the ultrasound and stem cells in organ transplantation.
The study of ultrasonic irradiation effects on solid state powders of HTc superconductor YBa2Cu3O7-x
NASA Astrophysics Data System (ADS)
Kargar, Mahboubeh; Khoshnevisan, Bahram
2016-03-01
In this paper, an ultrasound assisted solid state synthesis method for high-temperature (HTc) YBa2Cu3O7-x (YBCO) superconductor nanostructures with different morphologies is presented. Here, the routine heat treatment of the powder mixture of as-prepared precursors is followed by the ultrasound irradiation inside various alcoholic solutions. Not only the influence of the ultrasound irradiation intensity and duration but also the influence of different solvents such as ethanol, methanol and 1-butanol with various vapor pressures and so various destruction powers were also studied on the morphology and particle size of the products. The various morphologies were studied by scanning electron microscope (SEM) which not only have been affected by intensity and type of alcoholic solvent but also sonication time and ultrasound power have significant role as well. Formation of the YBCO superconducting phase was examined by using Rietveld refinement of X-ray diffraction (XRD) which indicates the crystalline preferred growth in c-axis orientation in crystal. Magnetic susceptibility measurements showed the ultrasound waves had no important effect on the onset critical temperature of the prepared nanorods (about 91.64 K) which is compared with the bulk samples (Tc ˜ 92K).
NASA Astrophysics Data System (ADS)
Wang, Shutao; Raju, Balasundar I.; Leyvi, Evgeniy; Weinstein, David A.; Seip, Ralf
2012-10-01
Glycogen storage disease type Ia (GSDIa) is caused by an inherited single-gene defect resulting in an impaired glycogen to glucose conversion pathway. Targeted ultrasound mediated delivery (USMD) of plasmid DNA (pDNA) to liver in conjunction with microbubbles may provide a potential treatment for GSDIa patients. As the success of USMD treatments is largely dependent on the accessibility of the targeted tissue by the focused ultrasound beam, this study presents a quantitative approach to determine the acoustically accessible liver volume in GSDIa patients. Models of focused ultrasound beam profiles for transducers of varying aperture and focal lengths were applied to abdomen models reconstructed from suitable CT and MRI images. Transducer manipulations (simulating USMD treatment procedures) were implemented via transducer translations and rotations with the intent of targeting and exposing the entire liver to ultrasound. Results indicate that acoustically accessible liver volumes can be as large as 50% of the entire liver volume for GSDIa patients and on average 3 times larger compared to a healthy adult group due to GSDIa patients' increased liver size. Detailed descriptions of the evaluation algorithm, transducer-and abdomen models are presented, together with implications for USMD treatments of GSDIa patients and transducer designs for USMD applications.
Olsen, Stine F; Blom, Hans C; Rosendahl, Karen
2018-02-01
There is no evidence on the effect of universal ultrasound screening on developmental dysplasia of the hip. We examined the impact of adding an ultrasound examination to a one examiner clinical screening strategy on treatment, follow-up rates and the number of cases detected late in a low-prevalence population. All eligible babies born at Kongsberg Hospital, Norway, from 1998 to 2006 (n = 4245) underwent both clinical and ultrasound hip examinations within three days of life. Indications for immediate treatment were positive Barlow or Ortolani manoeuvres and, or, sonographic dysplasia. Sonographic immature hips were followed until normalisation. Treatment rates and rates from the 1989 to 1997 prestudy period (n = 3594), including late diagnoses, were collected from hospital records. Treatment was initiated in 90 (2.1%) infants (74 girls), 63 (70%) from birth, compared to 33 (0.9%) during the prestudy period. The follow-up rate did not change (11%). There were two (0.5/1000) and four (1.0/1000) cases detected late, respectively. No one underwent surgery during the first year of life and no avascular necrosis was seen. Adding universal ultrasound to clinical screening performed by the same, experienced paediatrician doubled the treatment rate, without influencing the already low numbers of late cases. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Non-rigid registration for fusion of carotid vascular ultrasound and MRI volumetric datasets
NASA Astrophysics Data System (ADS)
Chan, R. C.; Sokka, S.; Hinton, D.; Houser, S.; Manzke, R.; Hanekamp, A.; Reddy, V. Y.; Kaazempur-Mofrad, M. R.; Rasche, V.
2006-03-01
In carotid plaque imaging, MRI provides exquisite soft-tissue characterization, but lacks the temporal resolution for tissue strain imaging that real-time 3D ultrasound (3DUS) can provide. On the other hand, real-time 3DUS currently lacks the spatial resolution of carotid MRI. Non-rigid alignment of ultrasound and MRI data is essential for integrating complementary morphology and biomechanical information for carotid vascular assessment. We assessed non-rigid registration for fusion of 3DUS and MRI carotid data based on deformable models which are warped to maximize voxel similarity. We performed validation in vitro using isolated carotid artery imaging. These samples were subjected to soft-tissue deformations during 3DUS and were imaged in a static configuration with standard MR carotid pulse sequences. Registration of the source ultrasound sequences to the target MR volume was performed and the mean absolute distance between fiducials within the ultrasound and MR datasets was measured to determine inter-modality alignment quality. Our results indicate that registration errors on the order of 1mm are possible in vitro despite the low-resolution of current generation 3DUS transducers. Registration performance should be further improved with the use of higher frequency 3DUS prototypes and efforts are underway to test those probes for in vivo 3DUS carotid imaging.
Ultrasound Fissure Observation: Assessment of Lung by Pleural-Hub Affiliates.
Zanforlin, Alessandro; Livi, Vanina; Santoriello, Carlo; Ceruti, Paolo; Trigiani, Marco; Valerio, Manlio; Perani, Cristiano; Carlucci, Paolo; Palmiotti, Antonio; Marchetti, Giampietro
2018-02-22
Lung ultrasound examination is becoming an even more important part of pulmonologists' clinical routine. As indicated in the literature, the coordinates of any findings on lung parenchyma are based on surface landmarks or conventional quadrants. In our experience we have noticed that lung fissures are clearly detectable as interruptions of the pleural line, but this has never been investigated previously. The aim of this study was to evaluate whether lung fissures are detectable under normal conditions in routine clinical practice. Ten operators were enrolled from Pleural-Hub, a scientific discussion group. After compiling a prestudy survey to investigate whether they had observed fissures previously, they were asked to note if the following fissures were detectable: posterior right (PR) and left (PL), lateral right (LR) and left (LL), anterior right (AR), and anterolateral left (AL). Enrollment was competitive, aiming to reach 100 case subjects. We found that general fissure detection was 61.3%, in particular: PR, 59%; LR, 75%; AR, 69%; PL, 45%; LL, 64%; AL, 56%. Single operators yielded different detection rates ranging from 90% to 25%, showing strong operator dependency. Before being made aware of general results operators indicated operator's skill and rib shadow artifacts as the principal factors affecting fissure detection. Lung fissures may be detected with ultrasound once adequate training is provided. This may allow the clinician a more precise anatomical delineation of pathology identified by lung ultrasound. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Macione, J; Depaula, C A; Guzelsu, N; Kotha, S P
2010-07-01
Previous studies indicate that changes in the longitudinal elastic properties of bone due to changes in mineral content are related to the longitudinal strength of bone tissue. Changes in mineral content are expected to affect bone tissue mechanical properties along all directions, albeit to different extents. However, changes in tissue mechanical properties along the different directions are expected to be correlated to one another. In this study, we investigate if radial, circumferential, and longitudinal moduli are related in bone tissue with varying mineral content. Plexiform bovine femoral bone samples were treated in fluoride ion solutions for a period of 3 and 12 days to obtain bones with 20% and 32% lower effective mineral contents. Transmission ultrasound velocities were obtained in the radial, circumferential, and longitudinal axes of bone and combined with measured densities to obtain corresponding tensorial moduli. Results indicate that moduli decreased with fluoride ion treatments and were significantly correlated to one another (r(2) radial vs. longitudinal = 0.80, r(2) circumferential vs. longitudinal = 0.90, r(2) radial vs. circumferential = 0.85). Densities calculated from using ultrasound parameters, acoustic impedance and transmission velocities, were moderately correlated to those measured by the Archimedes principle (r(2)=0.54, p<0.01). These results suggest that radial and circumferential ultrasound measurements could be used to determine the longitudinal properties of bone and that ultrasound may not be able to predict in vitro densities of bones containing unbonded mineral. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Smith, Craig; Morscher, Gregory N.; Xia, Zhenhai
2008-01-01
Ceramic matrix composites are suitable for high temperature structural applications such as turbine airfoils and hypersonic thermal protection systems. The employment of these materials in such applications is limited by the ability to process components reliable and to accurately monitor and predict damage evolution that leads to failure under stressed-oxidation conditions. Current nondestructive methods such as ultrasound, x-ray, and thermal imaging are limited in their ability to quantify small scale, transverse, in-plane, matrix cracks developed over long-time creep and fatigue conditions. Electrical resistance of SiC/SiC composites is one technique that shows special promise towards this end. Since both the matrix and the fibers are conductive, changes in matrix or fiber properties should relate to changes in electrical conductivity along the length of a specimen or part. Initial efforts to quantify the electrical resistance of different fiber and different matrix SiC/SiC composites will be presented. Also, the effect of matrix cracking on electrical resistivity for several composite systems will be presented. The implications towards electrical resistance as a technique applied to composite processing, damage detection, and life-modeling will be discussed.
Joyce, E; Phull, S S; Lorimer, J P; Mason, T J
2003-10-01
Some species of bacteria produce colonies and spores which agglomerate in spherical clusters (Bacillus subtilis) and this serves as a protection for the organisms inside against biocidal attack. Flocs of fine particles e.g. clay can entrap bacteria which can also protect them against the biocides. It is because of problems such as these that alternative methods of disinfecting water are under active investigation. One such method is the use of power ultrasound, either alone or in combination with other methods. Ultrasound is able to inactivate bacteria and deagglomerate bacterial clusters or flocs through a number of physical, mechanical and chemical effects arising from acoustic cavitation. The aim of this study was to investigate the effect of power ultrasound at different powers and frequencies on Bacillus subtilis. Viable plate count techniques were used as a measure of microbial activity. Results showed a significant increase in percent kill for Bacillus species with increasing duration of exposure and intensity of ultrasound in the low-kilohertz range (20 and 38 kHz). Results obtained at two higher frequencies (512 and 850 kHz) indicated a significant increase in bacteria count suggesting declumping. In assessing the bacterial kill with time under different sonication regimes three types of behaviour were characterized: High power ultrasound (lower frequencies) in low volumes of bacterial suspension results in a continuous reduction in bacterial cell numbers i.e. the kill rate predominates. High power ultrasound (lower frequencies) in larger volumes results in an initial rise in cell numbers suggesting declumping of the bacteria but this initial rise then falls as the declumping finishes and the kill rate becomes more important. Low intensity ultrasound (higher frequencies) gives an initial rise in cell numbers as a result of declumping. The kill rate is low and so there is no significant subsequent decrease in bacterial cell numbers.
Ultrasound mediated transdermal insulin delivery in pigs using a lightweight transducer.
Park, E J; Werner, Jacob; Smith, Nadine Barrie
2007-07-01
In previous studies, ultrasound mediated transdermal drug delivery has shown a promising potential as a method for noninvasive drug administration. For prospective future human application, this study was designed to determine the feasibility of lightweight cymbal transducer array as a practical device for noninvasive transdermal insulin delivery in large pigs. Six Yorkshire pigs (100-140 lbs) were divided into two groups. As the control (n = 3), the first group did not receive any ultrasound exposure with the insulin. The second group (n = 3) was treated with ultrasound and insulin at 20 kHz with an I(sptp) = 100 mW/cm(2) at a 20% duty cycle for 60 min. With the pigs in lateral recumbency after anesthesia, the ultrasound transducer with insulin was placed on the axillary area of the pig. At the beginning and every 15 min up to 90 min, the blood glucose level was determined using a glucose monitoring system. To compare the results of individual animals, the change of blood glucose level was normalized to each animal's initial glucose value at the start of the experiment. Although each animal had a different initial glucose level, the mean and standard error for the six animals was 146 +/- 13 mg/dl. For the control group, the blood glucose level increased to 31 +/- 21 mg/dl compared to the initial baseline over the 90 min experiment. However for the ultrasound with insulin treated group, the glucose level decreased to -72 +/- 5 mg/dl at 60 min (p < 0.05) and continued to decrease to -91 +/- 23 mg/dl in 90 min (p < 0.05). The results indicate the feasibility of ultrasound mediated transdermal insulin delivery using the cymbal transducer array in animal with a similar size and weight to a human. Based on these result, the cymbal array has potential as a practical ultrasound system for noninvasive transdermal insulin delivery for diabetes management.
Shaw-Battista, Jenna; Young-Lin, Nichole; Bearman, Sage; Dau, Kim; Vargas, Juan
2015-01-01
Ultrasound is an important aid in the clinical diagnosis and management of normal and complicated pregnancy and childbirth. The technology is widely applied to maternity care in the United States, where comprehensive standard ultrasound examinations are routine. Targeted scans are common and used for an increasing number of clinical indications due to emerging research and a greater availability of equipment with better image resolution at lower cost. These factors contribute to an increased demand for obstetric ultrasound education among students and providers of maternity care, despite a paucity of data to inform education program design and evaluation. To meet this demand, from 2012 to 2015 the University of California, San Francisco nurse-midwifery education program developed and implemented an interprofessional obstetric ultrasound course focused on clinical applications commonly managed by maternity care providers from different professions and disciplines. The course included matriculating students in nursing and medicine, as well as licensed practitioners such as registered and advanced practice nurses, midwives, and physicians and residents in obstetrics and gynecology and family medicine. After completing 10 online modules with a pre- and posttest of knowledge and interprofessional competencies related to teamwork and communication, trainees attended a case-based seminar and hands-on skills practicum with pregnant volunteers. The course aimed to establish a foundation for further supervised clinical training prior to independent practice of obstetric ultrasound. Course development was informed by professional guidelines and clinical and education research literature. This article describes the foundations, with a review of the challenges and solutions encountered in obstetric ultrasound education development and implementation. Our experience will inform educators who wish to facilitate obstetric ultrasound competency development among new and experienced maternity care providers in academic and clinical settings. This article is part of a special series of articles that address midwifery innovations in clinical practice, education, interprofessional collaboration, health policy, and global health. © 2015 by the American College of Nurse-Midwives.
Gyftopoulos, Soterios; Guja, Kip E; Subhas, Naveen; Virk, Mandeep S; Gold, Heather T
2017-12-01
The purpose of this study was to determine the value of magnetic resonance imaging (MRI) and ultrasound-based imaging strategies in the evaluation of a hypothetical population with a symptomatic full-thickness supraspinatus tendon (FTST) tear using formal cost-effectiveness analysis. A decision analytic model from the health care system perspective for 60-year-old patients with symptoms secondary to a suspected FTST tear was used to evaluate the incremental cost-effectiveness of 3 imaging strategies during a 2-year time horizon: MRI, ultrasound, and ultrasound followed by MRI. Comprehensive literature search and expert opinion provided data on cost, probability, and quality of life estimates. The primary effectiveness outcome was quality-adjusted life-years (QALYs) through 2 years, with a willingness-to-pay threshold set to $100,000/QALY gained (2016 U.S. dollars). Costs and health benefits were discounted at 3%. Ultrasound was the least costly strategy ($1385). MRI was the most effective (1.332 QALYs). Ultrasound was the most cost-effective strategy but was not dominant. The incremental cost-effectiveness ratio for MRI was $22,756/QALY gained, below the willingness-to-pay threshold. Two-way sensitivity analysis demonstrated that MRI was favored over the other imaging strategies over a wide range of reasonable costs. In probabilistic sensitivity analysis, MRI was the preferred imaging strategy in 78% of the simulations. MRI and ultrasound represent cost-effective imaging options for evaluation of the patient thought to have a symptomatic FTST tear. The results indicate that MRI is the preferred strategy based on cost-effectiveness criteria, although the decision between MRI and ultrasound for an imaging center is likely to be dependent on additional factors, such as available resources and workflow. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Cell damage of hepatoma-22 cells exposed to continuous wave ultrasound.
Wang, Pan; Wang, Xiaobing; Liu, Quanhong
2012-01-01
The cellular response of hepatoma-22 cells to ultrasonic irradiation and the potential cause for the action were evaluated. Hepatoma-22 cells were subjected to ultrasound irradiation at a frequency of 2.17 MHz and a spatial average intensity of 1.6 W/cm2 for variable periods of time, and several biological parameters were analyzed. The terephthalic acid (TA) dosimetry method was used to evaluate the efficacies of irradiation parameters on the acoustic cavitation activity by monitoring hydroxyl radical (OH) production. Lactate dehydrogenase (LDH) leakage was assayed to investigate cell membrane integrity. The polarization value of fluorescent probe 1,6-diphenyl-1,3,5-hexatriene (DPH) was measured to monitor plasma membrane fluidity. The malonaldehyde content in cells was determined to reflect lipid peroxidation. Trypan blue exclusion was used to detect cell viability. Additionally, electron microscopy was used to observe morphological changes. The generation of intracellular reactive oxygen species, mitochondria swelling and the loss of mitochondria membrane potential were also investigated. The results showed that 1) the concentration of ·OH production by ultrasonic irradiation in air-saturated cell suspensions increased as ultrasound exposure time increased; 2) compared with control, lactate dehydrogenase leakage, the polarization value of 1,6-diphenyl-1,3,5-hexatriene, malonaldehyde content and cell lysis were significantly elevated when cells were treated by ultrasound for 60 s; 3) cytotoxicity by ultrasound irradiation was also accompanied by an increase in production of intracellular reactive oxygen species and dissipation of mitochondria membrane potential as well as by mitochondria swelling. Presently available information indicates that the plasma membrane and mitochondria are the main targets for ultrasound treatment, and free radicals formation such as ·OH due to ultrasound cavitation may play an important role in mediating these cellular response processes. Moreover the mechanical effect might also be involved in inducing cell damage because there was significant mitochondria membrane potential loss and no visible ROS detection when cells were exposed to ultrasound for 30 s.
Electrical Resistance Technique to Monitor SiC Composite Detection
NASA Technical Reports Server (NTRS)
Smith, Craig; Morscher, Gregory; Xia, Zhenhai
2008-01-01
Ceramic matrix composites are suitable for high temperature structural applications such as turbine airfoils and hypersonic thermal protection systems. The employment of these materials in such applications is limited by the ability to process components reliable and to accurately monitor and predict damage evolution that leads to failure under stressed-oxidation conditions. Current nondestructive methods such as ultrasound, x-ray, and thermal imaging are limited in their ability to quantify small scale, transverse, in-plane, matrix cracks developed over long-time creep and fatigue conditions. Electrical resistance of SiC/SiC composites is one technique that shows special promise towards this end. Since both the matrix and the fibers are conductive, changes in matrix or fiber properties should relate to changes in electrical conductivity along the length of a specimen or part. The effect of matrix cracking on electrical resistivity for several composite systems will be presented and some initial measurements performed at elevated temperatures under stress-rupture conditions. The implications towards electrical resistance as a technique applied to composite processing, damage detection (health monitoring), and life-modeling will be discussed.
Renal sympathetic nervous system and the effects of denervation on renal arteries
Kannan, Arun; Medina, Raul Ivan; Nagajothi, Nagapradeep; Balamuthusamy, Saravanan
2014-01-01
Resistant hypertension is associated with chronic activation of the sympathetic nervous system resulting in various comorbidities. The prevalence of resistant hypertension is often under estimated due to various reasons. Activation of sympathetic nervous system at the renal- as well as systemic- level contributes to the increased level of catecholamines and resulting increase in the blood pressure. This increased activity was demonstrated by increased muscle sympathetic nerve activity and renal and total body noradrenaline spillover. Apart from the hypertension, it is hypothesized to be associated with insulin resistance, congestive heart failure and obstructive sleep apnea. Renal denervation is a novel procedure where the sympathetic afferent and efferent activity is reduced by various techniques and has been used successfully to treat drug-resistant hypertension improvement of various metabolic derangements. Renal denervation has the unique advantage of offering the denervation at the renal level, thus mitigating the systemic side effects. Renal denervation can be done by various techniques including radiofrequency ablation, ultrasound guided ablation and chemical ablation. Various trials evaluated the role of renal denervation in the management of resistant hypertension and have found promising results. More studies are underway to evaluate the role of renal denervation in patients presenting with resistant hypertension in different scenarios. Appropriate patient selection might be the key in determining the effectiveness of the procedure. PMID:25228960
Renal sympathetic nervous system and the effects of denervation on renal arteries.
Kannan, Arun; Medina, Raul Ivan; Nagajothi, Nagapradeep; Balamuthusamy, Saravanan
2014-08-26
Resistant hypertension is associated with chronic activation of the sympathetic nervous system resulting in various comorbidities. The prevalence of resistant hypertension is often under estimated due to various reasons. Activation of sympathetic nervous system at the renal- as well as systemic- level contributes to the increased level of catecholamines and resulting increase in the blood pressure. This increased activity was demonstrated by increased muscle sympathetic nerve activity and renal and total body noradrenaline spillover. Apart from the hypertension, it is hypothesized to be associated with insulin resistance, congestive heart failure and obstructive sleep apnea. Renal denervation is a novel procedure where the sympathetic afferent and efferent activity is reduced by various techniques and has been used successfully to treat drug-resistant hypertension improvement of various metabolic derangements. Renal denervation has the unique advantage of offering the denervation at the renal level, thus mitigating the systemic side effects. Renal denervation can be done by various techniques including radiofrequency ablation, ultrasound guided ablation and chemical ablation. Various trials evaluated the role of renal denervation in the management of resistant hypertension and have found promising results. More studies are underway to evaluate the role of renal denervation in patients presenting with resistant hypertension in different scenarios. Appropriate patient selection might be the key in determining the effectiveness of the procedure.
Ultrasonically enhanced fractionation of milk fat in a litre-scale prototype vessel.
Leong, Thomas; Johansson, Linda; Mawson, Raymond; McArthur, Sally L; Manasseh, Richard; Juliano, Pablo
2016-01-01
The ultrasonic fractionation of milk fat in whole milk to fractions with distinct particle size distributions was demonstrated using a stage-based ultrasound-enhanced gravity separation protocol. Firstly, a single stage ultrasound gravity separation was characterised after various sonication durations (5-20 min) with a mass balance, where defined volume partitions were removed across the height of the separation vessel to determine the fat content and size distribution of fat droplets. Subsequent trials using ultrasound-enhanced gravity separation were carried out in three consecutive stages. Each stage consisted of 5 min sonication, with single and dual transducer configurations at 1 MHz and 2 MHz, followed by aliquot collection for particle size characterisation of the formed layers located at the bottom and top of the vessel. After each sonication stage, gentle removal of the separated fat layer located at the top was performed. Results indicated that ultrasound promoted the formation of a gradient of vertically increasing fat concentration and particle size across the height of the separation vessel, which became more pronounced with extended sonication time. Ultrasound-enhanced fractionation provided fat enriched fractions located at the top of the vessel of up to 13 ± 1% (w/v) with larger globules present in the particle size distributions. In contrast, semi-skim milk fractions located at the bottom of the vessel as low as 1.2 ± 0.01% (w/v) could be produced, containing proportionally smaller sized fat globules. Particle size differentiation was enhanced at higher ultrasound energy input (up to 347 W/L). In particular, dual transducer after three-stage operation at maximum energy input provided highest mean particle size differentiation with up to 0.9 μm reduction in the semi-skim fractions. Higher frequency ultrasound at 2 MHz was more effective in manipulating smaller sized fat globules retained in the later stages of skimming than 1 MHz. While 2 MHz ultrasound removed 59 ± 2% of the fat contained in the initial sample, only 47 ± 2% was removed with 1 MHz after 3 ultrasound-assisted fractionation stages. Copyright © 2015 Elsevier B.V. All rights reserved.
Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.
Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O
2013-12-01
Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Recognition of finger flexion motion from ultrasound image: a feasibility study.
Shi, Jun; Guo, Jing-Yi; Hu, Shu-Xian; Zheng, Yong-Ping
2012-10-01
Muscle contraction results in structural and morphologic changes of the related muscle. Therefore, finger flexion can be monitored from measurements of these morphologic changes. We used ultrasound imaging to record muscle activities during finger flexion and extracted features to discriminate different fingers' flexions using a support vector machine (SVM). Registration of ultrasound images before and after finger flexion was performed to generate a deformation field, from which angle features and wavelet-based features were extracted. The SVM was then used to classify the motions of different fingers. The experimental results showed that the overall mean recognition accuracy was 94.05% ± 4.10%, with the highest for the thumb (97%) and the lowest for the ring finger (92%) and the mean F value was 0.94 ± 0.02, indicating high accuracy and reliability of this method. The results suggest that the proposed method has the potential to be used as an alternative method of surface electromyography in differentiating the motions of different fingers. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Baran, Talat
2018-07-01
This study describes (i) an eco-friendly approach for design of Pd(0) nanoparticles on a natural composite, which is composed of carboxymethyl cellulose/agar polysaccharides (CMC/AG), without using any toxic reducing agents and (ii) development of ultrasound assisted simple protocol for synthesis of biphenyl compounds. Chemical characterization studies of Pd(0) nanoparticles (Pd NPs@CMC/AG) revealed that size of the particles were in the range of 37-55 nm. Catalytic performance of Pd NPs@CMC/AG was evaluated in synthesis of various biphenyl compounds by using the ultrasound-assisted method that was developed in this study. Pd NPs@CMC/AG exhibited excellent catalytic performance by producing high reaction yields. In addition, Pd NPs@CMC/AG was successfully used up to six reaction cycles without losing its catalytic activity, indicating high reproducibility of Pd NPs@CMC/AG. Additionally, compared to conventional the methods, new ultrasound-assisted synthesis technique that was followed in this study exhibited some advantages such as shorter reaction time, greener reaction conditions, higher yields and easier work-up. Copyright © 2018 Elsevier B.V. All rights reserved.
Ultrasound accelerated Claisen Schmidt condensation: A green route to chalcones
NASA Astrophysics Data System (ADS)
Calvino, V.; Picallo, M.; López-Peinado, A. J.; Martín-Aranda, R. M.; Durán-Valle, C. J.
2006-06-01
Chalcones have been synthesized under sonochemical irradiation by Claisen-Schmidt condensation between benzaldehyde and acetophenone. Two basic activated carbons (Na and Cs-Norit) have been used as catalysts. The effect of the ultrasound activation has been studied. A substantial enhancing effect in the yield was observed when the carbon catalyst was activated under ultrasonic waves. This "green" method (combination of alkaline-doped carbon catalyst and ultrasound waves) has been applied to the synthesis of several chalcones with antibacterial properties achieving, in all cases, excellent activities and selectivities. A comparative study under non-sonic activation has showed that the yields are lower in silent conditions, indicating that the sonication exerts a positive effect on the activity of the catalyst. Cs-doped carbon is presented as the optimum catalyst, giving excellent activity for this type of condensation. Cs-Norit carbon catalyst can compete with the traditional NaOH/EtOH when the reaction is carried out under ultrasounds. The role of solvent in this reaction was studied with ethanol. High conversion was obtained in absence of solvent. The carbons were characterized by thermal analysis, nitrogen adsorption and X-ray photoelectron spectroscopy.
Influence of Scan Duration on Pulmonary Capillary Hemorrhage Induced by Diagnostic Ultrasound.
Miller, Douglas L; Dong, Zhihong; Dou, Chunyan; Raghavendran, Krishnan
2016-08-01
Diagnostic ultrasound can induce pulmonary capillary hemorrhage (PCH) in rats and display this as "comet tail" artifacts (CTAs) after a time delay. To test the hypothesis that no PCH occurs for brief scans, anesthetized rats were scanned using a 6-MHz linear array for different durations. PCH was characterized by ultrasound CTAs, micro-computed tomography (μCT), and measurements of fixed lung tissue. The μCT images revealed regions of PCH, sometimes penetrating the entire depth of a lobe, which were reflected in the fixed tissue measurements. At -3 dB of power, PCH was substantial for 300-s scans, but not significant for 25-s scans. At 0 dB, PCH was not strongly dependent on scan durations of 300 to 10 s. Contrary to the hypothesis, CTAs were not evident during most 10-s scans (p > 0.05), but PCH was significant (p = 0.02), indicating that PCH could occur without evidence of the injury in the images. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Pajek, Daniel; Burgess, Alison; Huang, Yuexi; Hynynen, Kullervo
2014-09-01
The purpose of this study was to evaluate use of intravascular perfluorocarbon droplets to reduce the sonication power required to achieve clot lysis with high-intensity focused ultrasound. High-intensity focused ultrasound with droplets was initially applied to blood clots in an in vitro flow apparatus, and inertial cavitation thresholds were determined. An embolic model for ischemic stroke was used to illustrate the feasibility of this technique in vivo. Recanalization with intravascular droplets was achieved in vivo at 24 ± 5% of the sonication power without droplets. Recanalization occurred in 71% of rabbits that received 1-ms pulsed sonications during continuous intravascular droplet infusion (p = 0.041 vs controls). Preliminary experiments indicated that damage was confined to the ultrasonic focus, suggesting that tolerable treatments would be possible with a more tightly focused hemispheric array that allows the whole focus to be placed inside of the main arteries in the human brain. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Should nurses be trained to use ultrasound for intravenous access to patients with difficult veins?
Smith, Claire
2018-06-14
Peripheral venous access is the most common invasive procedure performed on patients in the UK and is traditionally the responsibility of nursing staff. In an emergency, intravenous therapy can be lifesaving. Approximately 11% of adults have difficult venous access and are often subjected to repeated failed attempts, resulting in delayed diagnosis and treatment. Eventually, rescue methods are used by a doctor, but this increases demand on their time and the workflow of emergency departments. This article explores whether training nurses to obtain venous access using ultrasound would have a positive effect on doctors' workload and benefit adult patients with difficult veins. Research indicates that nurses can successfully use ultrasound to reduce the number of attempts, time to access and patient discomfort, and can prevent the insertion of unnecessary central lines. Ultrasound training programmes for nurses demonstrate benefits for patients and clinicians. © 2018 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.
Can airborne ultrasound monitor bubble size in chocolate?
NASA Astrophysics Data System (ADS)
Watson, N.; Hazlehurst, T.; Povey, M.; Vieira, J.; Sundara, R.; Sandoz, J.-P.
2014-04-01
Aerated chocolate products consist of solid chocolate with the inclusion of bubbles and are a popular consumer product in many countries. The volume fraction and size distribution of the bubbles has an effect on their sensory properties and manufacturing cost. For these reasons it is important to have an online real time process monitoring system capable of measuring their bubble size distribution. As these products are eaten by consumers it is desirable that the monitoring system is non contact to avoid food contaminations. In this work we assess the feasibility of using an airborne ultrasound system to monitor the bubble size distribution in aerated chocolate bars. The experimental results from the airborne acoustic experiments were compared with theoretical results for known bubble size distributions using COMSOL Multiphysics. This combined experimental and theoretical approach is used to develop a greater understanding of how ultrasound propagates through aerated chocolate and to assess the feasibility of using airborne ultrasound to monitor bubble size distribution in these systems. The results indicated that a smaller bubble size distribution would result in an increase in attenuation through the product.
Examining Neosho madtom reproductive biology using ultrasound and artificial photothermal cycles
Bryan, J.L.; Wildhaber, M.L.; Noltie, Douglas B.
2005-01-01
We examined whether extended laboratory simulation of natural photothermal conditions could stimulate reproduction in the Neosho madtom Noturus placidus, a federally threatened species. For 3 years, a captive population of Neosho madtoms was maintained under simulated natural conditions and monitored routinely with ultrasound for reproductive condition. Female Neosho madtoms cycled in and out of spawning condition, producing and absorbing oocytes annually. Internal measurements made by means of ultrasound indicated the summer mean oocyte size remained consistent over the years, although estimated fecundity increased with increasing fish length. In the summer of 2001, after 3 years in the simulated natural environment, 13 out of 41 fish participated in 10 spawnings. Simulation of the natural photothermal environment, coupled with within-day temperature fluctuations during the spring rise, seemed important for the spawning of captive Neosho madtoms. The use of ultrasound to assess the reproductive status in Neosho madtoms was effective and resulted in negligible stress or injury to the fish. These procedures may facilitate future culture of this species and other madtoms Noturus spp., especially when species are rare, threatened, or endangered. ?? Copyright by the American Fisheries Society 2005.
Preparation and characterization of a novel silicon-modified nanobubble
Li, Maotong; Zhou, Meijun; Li, Fei; Huang, Xiuxian; Pan, Min; Xue, Li
2017-01-01
Nanobubbles (NBs) opened a new field of ultrasound imaging. There is still no practical method to control the diameter of bubbles. In this study, we developed a new method to control the size by incorporating of silicon hybrid lipids into the bubble membrane. The range of particle size of resulting NBs is between 523.02 ± 46.45 to 857.18 ± 82.90, smaller than the conventional microbubbles. The size of resulting NBs increased with the decrease in amount of silicon hybrid lipids, indicating the diameter of NBs can be regulated through modulating the ratio of silicon hybrid lipids in the bubble shell. Typical harmonic signals could be detected. The in vitro and in vivo ultrasound imaging experiments demonstrated these silicon-modified NBs had significantly improved ultrasound contrast enhancement abilities. Cytotoxicity assays revealed that these NBs had no obvious cytotoxicity to the 293 cell line at the tested bubble concentration. Our results showed that the novel NBs could use as nanoscale ultrasound contrast agents, providing the foundation for NBs in future applications including contrast-enhanced imaging and drug/gene delivery. PMID:28557995
Effects of age, sex, and ethnicity on bone health status of the elderly in Kuala Lumpur, Malaysia
Chin, Kok-Yong; Kamaruddin, Alia Annessa Ain; Low, Nie Yen; Ima-Nirwana, Soelaiman
2016-01-01
Background Osteoporosis is a significant health problem in the developing countries and its prevalence data are important for the estimation of health care burden and policy making. This study aimed to determine the age-related changes in bone health and the prevalence of osteoporosis in males and females aged 50 years or above living in Kuala Lumpur, Malaysia. Methods A cross-sectional study was conducted between December 2014 and December 2015. Subjects answered a demographic questionnaire and underwent body anthropometric and bone health measurement. Assessment of bone health was performed using a quantitative ultrasound device that generated speed of sound, broadband ultrasound attenuation, stiffness index, and T-score based on stiffness index value as bone health indices. Results The prevalence of osteoporosis was 10.6% in males and 8.0% in females. Significant age-related decline of bone health indices (speed of sound, broadband ultrasound attenuation, stiffness index, and T-score) and a concurrent increase in the prevalence of osteoporosis and osteopenia were observed in females (P<0.05) but not in males (P>0.05). Ethnic differences in bone health indices and prevalence of osteoporosis/osteopenia were not observed (P>0.05). Conclusion A significant proportion of males and females age 50 years or above have suboptimal bone health. Preventive measures such as early screening should be implemented to retard the progression of osteoporosis. PMID:27358558
AltitudeOmics: effect of ascent and acclimatization to 5260 m on regional cerebral oxygen delivery.
Subudhi, Andrew W; Fan, Jui-Lin; Evero, Oghenero; Bourdillon, Nicolas; Kayser, Bengt; Julian, Colleen G; Lovering, Andrew T; Roach, Robert C
2014-05-01
Cerebral hypoxaemia associated with rapid ascent to high altitude can be life threatening; yet, with proper acclimatization, cerebral function can be maintained well enough for humans to thrive. We investigated adjustments in global and regional cerebral oxygen delivery (DO2) as 21 healthy volunteers rapidly ascended and acclimatized to 5260 m. Ultrasound indices of cerebral blood flow in internal carotid and vertebral arteries were measured at sea level, upon arrival at 5260 m (ALT1; atmospheric pressure 409 mmHg) and after 16 days of acclimatization (ALT16). Cerebral DO2 was calculated as the product of arterial oxygen content and flow in each respective artery and summed to estimate global cerebral blood flow. Vascular resistances were calculated as the quotient of mean arterial pressure and respective flows. Global cerebral blood flow increased by ∼70% upon arrival at ALT1 (P < 0.001) and returned to sea-level values at ALT16 as a result of changes in cerebral vascular resistance. A reciprocal pattern in arterial oxygen content maintained global cerebral DO2 throughout acclimatization, although DO2 to the posterior cerebral circulation was increased by ∼25% at ALT1 (P = 0.032). We conclude that cerebral DO2 is well maintained upon acute exposure and acclimatization to hypoxia, particularly in the posterior and inferior regions of the brain associated with vital homeostatic functions. This tight regulation of cerebral DO2 was achieved through integrated adjustments in local vascular resistances to alter cerebral perfusion during both acute and chronic exposure to hypoxia. © 2013 The Authors. Experimental Physiology © 2013 The Physiological Society.
NASA Astrophysics Data System (ADS)
Li, Haibing; Xu, Zhiqin; Niu, Yixiong; Kong, Guangsheng; Huang, Yao; Wang, Huan; Si, Jialiang; Sun, Zhiming; Pei, Junling; Gong, Zheng; Chevalier, Marie-Luce; Liu, Dongliang
2014-04-01
The Wenchuan earthquake Fault Scientific Drilling project (WFSD) started right after the 2008 Mw 7.9 Wenchuan earthquake to investigate its faulting mechanism. Hole 1 (WFSD-1) reached the Yingxiu-Beichuan fault (YBF), and core samples were recovered from 32 to 1201.15 m-depth. Core investigation and a suite of geophysical downhole logs (including P-wave velocity, natural gamma ray, self-potential, resistivity, density, porosity, temperature, magnetic susceptibility and ultrasound borehole images) were acquired in WFSD-1. Integrated studies of cores and logs facilitate qualitative and quantitative comparison of the structures and physical properties of rocks. Logging data revealed that the geothermal gradient of the volcanic Pengguan complex (above 585.75 m) is 1.85 °C/100 m, while that of the sedimentary Xujiahe Formation (below 585.75 m) is 2.15 °C/100 m. In general, natural gamma ray, resistivity, density, porosity, P-wave velocity and magnetic susceptibility primarily depend on the rock lithology. All major fault zones are characterized by high magnetic susceptibility, low density and high porosity, with mostly low resistivity, high natural gamma ray and sound wave velocity. The high magnetic susceptibility values most likely result from the transformation of magnetic minerals by frictional heating due to the earthquake. The YBF exposed in WFSD-1 can be subdivided into five different parts based on different logging responses, each of them corresponding to certain fault-rocks. The high gamma radiation, porosity and P-wave velocity, as well as low resistivity and temperature anomalies indicate that the Wenchuan earthquake fault zone is located at 585.75-594.5 m-depth, with an average inclination and dip angle of N305° and 71°, respectively. The fact that the fracture directions in the hanging wall and footwall are different suggests that their stress field direction is completely different, implying that the upper Pengguan complex may not be local.