  1. Usage of Magnetic Resonance Guided Focused Ultrasound Surgery (mrgfus) in Oncology

    NASA Astrophysics Data System (ADS)

    Bauer, Yair

    2011-09-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) is a non-invasive incision-less surgical approach which limits the tissue destruction to the targeted tumor. Acoustic energy penetrates through intact skin and through the tissues surrounding the tumor without causing any significant bio-effects. Energy deposition takes place mainly at the focal spot where heat induced thermal coagulation of the targeted tissue is accomplished. Real time targeting and image guidance is provided by MRI tumor margin definition and real time thermometry provides closed loop feedback control of energy deposition. The patient lies in the MRI scanner throughout the treatment planning and treatment, and the physician conducts the treatment from the MRgFUS workstation in the adjacent MR control room. The ExAblate system for MRgFUS is commercially available in many countries for treatment of uterine fibroids. The system has also received CE and KFDA approval for pain palliation of bone metastases, and research of other oncologic applications is underway.

  2. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) of uterine fibroids in Singapore.

    PubMed

    Han, Nian-Lin R; Ong, Chiou Li

    2014-11-01

    Uterine fibroids are the most common type of gynaecologic benign tumours, occurring in 25% to 50% of women during their reproductive lives. About half of the affected women have clinically significant symptoms, including abnormal bleeding, menstrual pain, frequent urination, constipation and abdominal distension. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) has been used to treat patients with benign lesions and a variety of malignancies. The objective of this study is to evaluate symptom relief before and after MR-guided ultrasound ablation of fibroids. A total of 37 patients with symptomatic uterine fibroids were treated in this study. MRgFUS treatment led to a significant, time-dependent decrease in not only Symptom Severity Scores (SSS), but also the mean fibroid volume. The average reductions in volume were 41.6% and 52.6% at 6 months and 12 months respectively (P <0.05). The mean SSS of the 37 patients was 41.7 ± 2.8 before treatment whereas the average SSS was 26.9 ± 3.6, 20.7 ± 3.4, 18.5 ± 3.6, 16.5 ± 7.1, 9.8 ± 3.6 at 3 months, 6 months, 1 year, 2 years, and 3 to 4 years respectively. The decrease in scores was significant at all time points up to 3 to 4 years (P <0.05 and P <0.001). MRgFUS is a safe and effective non-invasive treatment for patients with symptomatic fibroids.

  3. Expulsion of Fibroids to the Endometrial Cavity after Magnetic Resonance Imaging-guided High Intensity Focused Ultrasound Surgery (MRgFUS) Treatment of Intramural Uterine Fibroids

    PubMed Central

    Jeong, Jae-Hyeok; Hong, Gil Pyo; Kim, Yu-Ri; Hong, Da Gyo; Ha, Jae-Eun; Yeom, Jung In; Kim, Eun-Jeong; Kim, Hyung-Il

    2016-01-01

    Objectives This report seeks to introduce some cases of the patients who received magnetic resonance imaging (MRI)-guided high intensity focused ultrasound (HIFU) surgery (MRgFUS)-based intramural uterine fibroids treatment where the post-MRgFUS intramural uterine fibroids decreased in its volume and protruded towards the endometrial cavity to be expelled by hysteroscopy. Methods Of the 157 patients who had received MRgFUS treatment in the Obstetrics and Gynecology of the Hospital from March, 2015 to February, 2016; this study examined 6 of the cases where, after high intensity focused ultrasound treatment, intramural uterine fibroids protruded towards the endometrial cavity to be removed by hysteroscopic myomectomy. The high intensity focused ultrasound utilized in the cases were Philips Achieva 1.5 Tesla MR (Philips Healthcare, Best, The Netherlands) and Sonalleve HIFU system. Results The volume of fibroids ranged from 26.0 cm3 to 199.5 cm3, averaging 95.6 cm3. The major axis length ranged from 4.0 cm to 8.2 cm, averaging 6.3 cm. Fibroid location in all of the patients was in intramural uterine before treatment but after the high intensity focused ultrasound treatment, the fibroids were observed to protrude towards the endometrial cavity in at least Day 5 or up to Day 73 to allow hysteroscopic myomectomy. Conclusions In some cases, after an intramural uterine fibroid is treated with MRgFUS, fibroid volume is decreased and the fibroid protrudes towards the endometrial cavity. In this case, hysteroscopic myomectomy can be a useful solution. PMID:28119893

  4. MRI-Guided Focused Ultrasound Surgery

    PubMed Central

    Jolesz, Ferenc A.

    2014-01-01

    MRI-guided focused ultrasound (MRgFUS) surgery is a noninvasive thermal ablation method that uses magnetic resonance imaging (MRI) for target definition, treatment planning, and closed-loop control of energy deposition. Integrating FUS and MRI as a therapy delivery system allows us to localize, target, and monitor in real time, and thus to ablate targeted tissue without damaging normal structures. This precision makes MRgFUS an attractive alternative to surgical resection or radiation therapy of benign and malignant tumors. Already approved for the treatment of uterine fibroids, MRgFUS is in ongoing clinical trials for the treatment of breast, liver, prostate, and brain cancer and for the palliation of pain in bone metastasis. In addition to thermal ablation, FUS, with or without the use of microbubbles, can temporarily change vascular or cell membrane permeability and release or activate various compounds for targeted drug delivery or gene therapy. A disruptive technology, MRgFUS provides new therapeutic approaches and may cause major changes in patient management and several medical disciplines. PMID:19630579

  5. Magnetic resonance-guided focused ultrasound surgery for treatment of painful osseous metastases

    NASA Astrophysics Data System (ADS)

    Hurwitz, Mark; Machtinger, Ronit; Fennessy, Fiona

    2011-03-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) is an emerging technology that can non-invasively heat and ablate targeted tissue utilizing ultrasound energy. Use of MR imaging for treatment guidance provides several key advantages over more widely used ultrasound guidance for focused ultrasound ablation. MR allows for precise targeting, detailed beam path visualization, real time non-invasive temperature measurement, and treatment feedback to ensure therapeutic goals are achieved. In the realm of oncology, management of painful bone metastases is a common and daunting clinical problem. The Insightec ExAblate System has been shown in phase I/II trials for treatment of bone metastases to have an excellent safety profile and high rates of pain response. An international multi-center phase III trial for patients with painful bone metastases or multiple myeloma who are not candidates for radiation therapy is currently open. Patients are randomized 3:1 to MRgFUS or sham treatment with crossover to study treatment allowed for sham failures. The primary study endpoint is assessment of pain control over 3 months following treatment. In addition safety, quality of life, cost effectiveness analysis, and patient perceived clinical benefit are also being assessed. Details of the MRgFUS system, technical and clinical therapeutic parameters, use of real time non-invasive MR thermometry, and examples of patient treatments with use of MRgFUS to treat bone metastases will be discussed. New directions in use of MRgFUS including an update on development of a new mobile applicator and integration of MRgFUS in multimodality oncologic care will also be presented.

  6. MR-guided focused ultrasound surgery, present and future

    PubMed Central

    Schlesinger, David; Benedict, Stanley; Diederich, Chris; Gedroyc, Wladyslaw; Klibanov, Alexander; Larner, James

    2013-01-01

    MR-guided focused ultrasound surgery (MRgFUS) is a quickly developing technology with potential applications across a spectrum of indications traditionally within the domain of radiation oncology. Especially for applications where focal treatment is the preferred technique (for example, radiosurgery), MRgFUS has the potential to be a disruptive technology that could shift traditional patterns of care. While currently cleared in the United States for the noninvasive treatment of uterine fibroids and bone metastases, a wide range of clinical trials are currently underway, and the number of publications describing advances in MRgFUS is increasing. However, for MRgFUS to make the transition from a research curiosity to a clinical standard of care, a variety of challenges, technical, financial, clinical, and practical, must be overcome. This installment of the Vision 20/20 series examines the current status of MRgFUS, focusing on the hurdles the technology faces before it can cross over from a research technique to a standard fixture in the clinic. It then reviews current and near-term technical developments which may overcome these hurdles and allow MRgFUS to break through into clinical practice. PMID:23927296

  7. MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics

    PubMed Central

    Napoli, Alessandro; Sacconi, Beatrice; Battista, Giuseppe; Guglielmi, Giuseppe; Catalano, Carlo; Albisinni, Ugo

    2016-01-01

    MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a “new” interventional technique and on its applications for MSK and allied sciences. PMID:26607640

  8. WE-G-12A-01: High Intensity Focused Ultrasound Surgery and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farahani, K; O'Neill, B

    More and more emphasis is being made on alternatives to invasive surgery and the use of ionizing radiation to treat various diseases including cancer. Novel screening, diagnosis, treatment and monitoring of response to treatment are also hot areas of research and new clinical technologies. Ultrasound(US) has gained traction in all of the aforementioned areas of focus. Especially with recent advances in the use of ultrasound to noninvasively treat various diseases/organ systems. This session will focus on covering MR-guided focused ultrasound and the state of the art clinical applications, and the second speaker will survey the more cutting edge technologies e.g.more » Focused Ultrasound (FUS) mediated drug delivery, principles of cavitation and US guided FUS. Learning Objectives: Fundamental physics and physical limitations of US interaction with tissue and nanoparticles The alteration of tissue transport using focused ultrasound US control of nanoparticle drug carriers for targeted release The basic principles of MRI-guided focused ultrasound (MRgFUS) surgery and therapy the current state of the art clinical applications of MRgFUS requirements for quality assurance and treatment planning.« less

  9. Neurosurgical Applications of High-Intensity Focused Ultrasound with Magnetic Resonance Thermometry.

    PubMed

    Colen, Rivka R; Sahnoune, Iman; Weinberg, Jeffrey S

    2017-10-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) has potential noninvasive effects on targeted tissue. MRgFUS integrates MRI and focused ultrasound surgery (FUS) into a single platform. MRI enables visualization of the target tissue and monitors ultrasound-induced effects in near real-time during FUS treatment. MRgFUS may serve as an adjunct or replace invasive surgery and radiotherapy for specific conditions. Its thermal effects ablate tumors in locations involved in movement disorders and essential tremors. Its nonthermal effects increase blood-brain barrier permeability to enhance delivery of therapeutics and other molecules. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. High intensity focused ultrasound surgery (HIFU) of the brain: A historical perspective, with modern applications

    PubMed Central

    Jagannathan, Jay; Sanghvi, Narendra K; Crum, Lawrence A; Yen, Chun-Po; Medel, Ricky; Dumont, Aaron S; Sheehan, Jason P; Steiner, Ladislau; Jolesz, Ferenc; Kassell, Neal F

    2014-01-01

    The field of MRI-guided high intensity focused ultrasound surgery (MRgFUS) is a rapidly evolving one with many potential applications in neurosurgery. This is the first of three articles on MRgFUS, this paper focuses on the historical development of the technology and it's potential applications to modern neurosurgery. The evolution of MRgFUS has occurred in parallel with modern neurological surgery and the two seemingly distinct disciplines share many of the same pioneering figures. Early studies on focused ultrasound treatment in the 1940's and 1950's demonstrated the ability to perform precise lesioning in the human brain, with a favorable risk-benefit profile. However, the need for a craniotomy, as well as lack of sophisticated imaging technology resulted in limited growth of HIFU for neurosurgery. More recently, technological advances, have permitted the combination of HIFU along with MRI guidance to provide an opportunity to effectively treat a variety of CNS disorders. Although challenges remain, HIFU-mediated neurosurgery may offer the ability to target and treat CNS conditions that were previously extremely difficult to perform. The remaining two articles in this series will focus on the physical principles of modern MRgFUS as well as current and future avenues for investigation. PMID:19190451

  11. Magnetic Resonance Guided Focused Ultrasound Surgery: Part 2 – A Review of Current and Future Applications

    PubMed Central

    Medel, Ricky; Monteith, Stephen J.; Elias, W. Jeffrey; Eames, Matthew; Snell, John; Sheehan, Jason P.; Wintermark, Max; Jolesz, Ferenc A.; Kassell, Neal F.

    2014-01-01

    Magnetic Resonance guided Focused Ultrasound Surgery (MRgFUS) represents a novel combination of technologies that is actively being realized as a non-invasive therapeutic tool for a myriad of conditions. These applications are reviewed with a focus on neurological utilization. A combined search of Pubmed and Medline was performed to identify the key events and current status of MRgFUS, with a focus on neurological applications. MRgFUS signifies a potentially ideal device for the treatment of neurological diseases. As it is nearly real-time, it allows monitored provision of treatment location and energy deposition, is noninvasive, thereby limiting or eliminating disruption of normal tissue, provides focal delivery of therapeutic agents, enhances radiation delivery, and permits modulation of neural function. Multiple clinical applications are currently in clinical use and many more are under active preclinical investigation. The therapeutic potential of MRgFUS is expanding rapidly. Although clinically in its infancy, preclinical and early phase I clinical trials in neurosurgery suggest a promising future for MRgFUS. Further investigation is necessary to define its true potential and impact. PMID:22791029

  12. Magnetic Resonance Imaging-Guided Focused Ultrasound Surgery for the Treatment of Symptomatic Uterine Fibroids.

    PubMed

    Geraci, Laura; Napoli, Alessandro; Catalano, Carlo; Midiri, Massimo; Gagliardo, Cesare

    2017-01-01

    Uterine fibroids, the most common benign tumor in women of childbearing age, may cause symptoms including pelvic pain, menorrhagia, dysmenorrhea, pressure, urinary symptoms, and infertility. Various approaches are available to treat symptomatic uterine fibroids. Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) represents a recently introduced noninvasive safe and effective technique that can be performed without general anesthesia, in an outpatient setting. We review the principles of MRgFUS, describing patient selection criteria for the treatments performed at our center and we present a series of five selected patients with symptomatic uterine fibroids treated with this not yet widely known technique, showing its efficacy in symptom improvement and fibroid volume reduction.

  13. Robotically assisted MRgFUS system

    NASA Astrophysics Data System (ADS)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael

    2010-03-01

    Magnetic resonance imaging guided focus ultrasound surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. The objective of this ongoing work is to establish an MRgFUS therapy unit consisting of a specially designed FUS applicator as an add-on to a commercial robotic assistance system originally designed for percutaneous needle interventions in whole-body MRI systems. The fully MR compatible robotic assistance system InnoMotion™ (Synthes Inc., West Chester, USA; formerly InnoMedic GmbH, Herxheim, Germany) offers six degrees of freedom. The developed add-on FUS treatment applicator features a fixed focus ultrasound transducer (f = 1.7 MHz; f' = 68 mm, NA = 0.44, elliptical shaped -6-dB-focus: 8.1 mm length; O/ = 1.1 mm) embedded in a water-filled flexible bellow. A Mylar® foil is used as acoustic window encompassed by a dedicated MRI loop coil. For FUS application, the therapy unit is directly connected to the head of the robotic system, and the treatment region is targeted from above. A newly in-house developed software tool allowed for complete remote control of the MRgFUS-robot system and online analysis of MRI thermometry data. The system's ability for therapeutic relevant focal spot scanning was tested in a closed-bore clinical 1.5 T MR scanner (Magnetom Symphony, Siemens AG, Erlangen, Germany) in animal experiments with pigs. The FUS therapy procedure was performed entirely under MRI guidance including initial therapy planning, online MR-thermometry, and final contrast enhanced imaging for lesion detection. In vivo trials proved the MRgFUS-robot system as highly MR compatible. MR-guided focal spot scanning experiments were performed and a well-defined pattern of thermal tissue lesions was created. A total in vivo positioning accuracy of the US focus better than 2 mm was estimated which is comparable to existing MRgFUS systems. The newly developed FUS-robotic system offers an accurate, highly flexible focus positioning. With its access

  14. Symptomatic improvement in uterine myomas after MRgFUS: 4 year follow up

    NASA Astrophysics Data System (ADS)

    Funaki, Kaoru; Fukunishi, Hidenobu

    2011-09-01

    Objective: To assess the long-term improvement in symptoms after magnetic resonance-guided focused ultrasound surgery (MRgFUS) for uterine myomas. Methods: Japanese women with symptomatic myomas underwent MRgFUS using the ExAblate 2000 system. The symptom severity score (SSS) was examined before and after the treatment at 3, 6, 12, 24, and 48 months. Simultaneously, we asked the patients' satisfaction level regarding the overall change of subjective symptoms: symptom free, improved a great deal, improved to some extent, no change, or worsened. The myoma volumes were measured at 6, 12, 24, 36 and 48 months after MRgFUS. Results: No severe adverse event occurred with any of the patients. The mean SSS value before treatment was 38.3±21.5 (n = 106), which diminished significantly during follow-up for 3-48 months after treatment. Patients' satisfaction level was favorable, although the response rate was low. Over 80% of the patients replied that their symptoms were improved to at least some extent, and over 50% of the patients replied that their symptoms were improved a great deal. This trend continued throughout this follow up period. The mean myoma volume was also decreased from the pretreatment volume in this follow up period. Conclusion: MRgFUS is an effective and safe method for treating symptomatic uterine myomas. Long-term symptomatic improvement is promising.

  15. Clinical Consideration of Treatment to Ablate Uterine Fibroids with Magnetic Resonance Imaging-guided High Intensity Focused Ultrasound (MRgFUS): Sonalleve

    PubMed Central

    Jeong, Jae-Hyeok; Hong, Gil Pyo; Kim, Yu-Ri; Ha, Jae-Eun

    2016-01-01

    Objectives Magnetic resonance imaging (MRI)-guided high intensity focused ultrasound surgery (MRgFUS) is a newly emerging non-invasive technique for the treatment of uterine fibroids. The purpose of this study is to review the clinical impact of MRgFUS. Methods This study examined 157 patients. The high intensity focused ultrasound (HIFU) utilized in this study was Philips Achieva 1.5 Tesla MR (Philips Healthcare, Best, the Netherlands) and Sonalleve HIFU system. The patients were followed in post-operative Month 1, Month 3, and Month 6 to investigate any change. Then, these were further classified according to the use of uterine stimulant (oxytocin) in parallel, Funaki Type of uterine fibroid, HIFU intensity, and non-perfused volume (NPV) ratio. Results When the uterine stimulant was utilized, the HIFU intensity was measured at significantly lower levels, compared with the group not using uterine stimulant, and treatment duration was significantly. The NPV ratio was found significantly higher in the group using uterine stimulant. Concerning the correlation between Funaki Type of uterine fibroid and average sonication power, it was found that the closer to Type I, the lower the sonication power, the shorter the treatment duration, and the higher the NPV ratio significantly. Conclusions In this study, it was found that the lower the Funaki Types of uterine fibroids, and the higher the NPV ratio immediately after the operation, the larger the uterine fibroid volume decrease and SSS change were. Also, if uterine stimulant was used in parallel in treatment, treatment duration and HIFU intensity could become shorter and lower. PMID:27617244

  16. Evaluation of the pain and local tenderness in bone metastasis treated with magnetic resonance-guided focused ultrasound surgery (MRgFUS)

    NASA Astrophysics Data System (ADS)

    Namba, Hirofumi; Kawasaki, Motohiro; Kato, Tomonari; Tani, Toshikazu; Ushida, Takahiro; Koizumi, Norihiro

    2017-03-01

    It has been reported that MRgFUS has pain palliative effects on the local pain in patients with bone metastasis. In general, a severity of pain has been evaluated using only subjective method with numerical rating scale (NRS) or visual analogue scale (VAS). It is important to evaluate local pain-palliative effects of MRgFUS treatment with objective and quantitative method. The aim of this study is to investigate changes in the severity of local pain of bone metastasis before and after MRgFUS treatments, measuring pressure pain threshold (PPT) using pressure algometer, and pain intensity using electrical stimulation device (the Pain Vision system) at most painful site of bone metastasis. We have conducted MRgFUS for pain palliation of bone metastasis for 8 patients, and evaluated the local tenderness quantitatively for 8 patients, and evaluated local pain intensity for 7 patients. Before the treatments, PPTs were 106.3kPa [40.0-431.5] at metastatic site and 344.8 kPa [206.0-667.0] at normal control site, which showed a significant difference. The PPTs at metastatic site shows a significant increase from 106.3 kPa [40.0-431.5] at the baseline to 270.5 kPa [93.5-533.5] at 3 months after the treatment. The NRS score shows a significant decrease from 6.0 [4-8] at baseline to 1 [0-3] at 3 months after the treatment. Similarly, the pain intensity shows a significant decrease 245 [96.3-888.7] at baseline to 55.9 [2.8-292] at 3 months after the treatment. The results of our study illustrate the pain-relieving effects of MRgFUS for the treatment of painful bone metastasis. PPT might be a useful parameter not only for assessing a treatment's effect, but also for the decision of the painful area to treat with MRgFUS. Pain Vision seems to be useful for quantitative and objective evaluation of local pain of painful bone metastasis.

  17. Efficacy of Magnetic Resonance-guided Focused Ultrasound Surgery for Bone Metastases Pain Palliation

    NASA Astrophysics Data System (ADS)

    Kawasaki, Motohiro; Nanba, Hirofumi; Kato, Tomonari; Tani, Toshikazu; Ushida, Takahiro

    2011-09-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) is a novel treatment method that achieves non-invasive thermal ablation by focusing many ultrasound waves on a target tissue with real-time monitoring of the location and temperature of the target during the procedure. We investigated the palliative effect on pain and safety of MRgFUS in painful bone metastases. Six patients (mean age, 65.8 years) who met eligibility criteria for the clinical study approved by our Institutional Ethics Committee based on the cooperative protocol were treated with MRgFUS. Targeted sites included the sacrum (n = 1), ilium (n = 2), scapula (n = 2), and femur (n = 1). The mean follow-up period was 9.2 months. All procedures were performed as a single-session treatment using the treatment system that is integrated into the patient table of a magnetic resonance image (MRI) scanner. Endpoints were change in the intensity of pain due to bone metastases from before to after the treatment, as measured on a numerical rating scale, pain interference with daily activities as determined by the Brief pain inventory (BPI), change in images, and safety. Pain relief was obtained in all patients early after treatment, with a reduction in the mean pain score from 6.0±1.3 at baseline to 1.2±1.0 at the end of follow-up as well as in pain interference with daily activities. The mean time required for a single-session treatment was 83.7±37.0 min, with a mean number of sonications required of 13.3±3.7 and mean energy applied of 846.4±273.5 J. No significant growth of tumors was observed, nor were there treatment-related adverse events. These results suggest that MRgFUS has a non-invasive palliative effect on the localized pain in patients with bone metastasis. MRgFUS could become an option in treatment strategies for painful bone metastases in the future.

  18. Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Karl D., E-mail: karl.price@sickkids.ca

    Purpose: Current treatment of intraventricular hemorrhage (IVH) involves cerebral shunt placement or an invasive brain surgery. Magnetic resonance-guided focused ultrasound (MRgFUS) applied to the brains of pediatric patients presents an opportunity to treat IVH in a noninvasive manner, termed “incision-less surgery.” Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to either range of motion or dexterity requirements. A novel robotic system is proposed to position a focused ultrasound transducer accurately above the head of a neonatal patient inside an MRI machine to deliver the therapy. Methods: A clinical Philips Sonalleve MRgFUS systemmore » was expanded to perform transcranial treatment. A five degree-of-freedom MR-conditional robot was designed and manufactured using MR compatible materials. The robot electronics and control were integrated into existing Philips electronics and software interfaces. The user commands the position of the robot with a graphical user interface, and is presented with real-time MR imaging of the patient throughout the surgery. The robot is validated through a series of experiments that characterize accuracy, signal-to-noise ratio degeneration of an MR image as a result of the robot, MR imaging artifacts generated by the robot, and the robot’s ability to operate in a representative surgical environment inside an MR machine. Results: Experimental results show the robot responds reliably within an MR environment, has achieved 0.59 ± 0.25 mm accuracy, does not produce severe MR-imaging artifacts, has a workspace providing sufficient coverage of a neonatal brain, and can manipulate a 5 kg payload. A full system demonstration shows these characteristics apply in an application environment. Conclusions: This paper presents a comprehensive look at the process of designing and validating a new robot from concept to implementation for use in an MR environment

  19. Magnetic resonance guided focused ultrasound surgery (MRgFUS) of bone metastases: From primary pain palliation to local tumor control

    NASA Astrophysics Data System (ADS)

    Napoli, A.; Leonardi, A.; Andrani, F.; Boni, F.; Anzidei, M.; Catalano, C.

    2017-03-01

    Purpose: To evaluate the clinical performance of MRgFUS in primary pain palliation of painful bone metastases and in local tumor control. Materials and Methods: We enrolled 26 consecutive patients (female/male 12/14; age: 64.7±7.5yrs) with painful bone metastases. Before and 3 months after MRgFUS treatment pain severity and pain interference scores were assessed according to Brief Pain Inventory-Quality of Life (BPI-QoL) criteria and patients underwent both CT and MRI. Local tumor control was evaluated according to lesion size, density and perfusion at CT, dynamic contrast enhancement at MRI (Discovery 750HD, GE; Gd-Bopta, Bracco) and metabolic activity at PET or scintigraphy. Patients were classified as responders or non-responders. Results: No treatment-related adverse events were recorded during the study. As statistically significant difference between baseline and follow-up values for both pain severity and pain interference scores was observed (p<0.05). Increased bone density was observed in 9/26 (34.6%) patients. Non-Perfused Volume values ranged between 20% and 92%. There was no difference in NPV values between responders and non-responders (46.7±24.2% [25 - 90 %] vs. 45±24.9% [20 - 93 %]; p=0.7). In 6 patients (5 prostate and 1 breast primary cancer) there was nearly absence of metabolic activity after treatment (mean SUV=1.2). Conclusion: MRgFUS can be safely and effectively used as the primary treatment for pain palliation in patients with painful bone metastases; moreover our experience demonstrated also a potential role for the MRgFUS in local tumor control.

  20. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery.

    PubMed

    Krafft, Axel J; Jenne, Jürgen W; Maier, Florian; Stafford, R Jason; Huber, Peter E; Semmler, Wolfhard; Bock, Michael

    2010-05-01

    Focused ultrasound surgery (FUS) is a highly precise noninvasive procedure to ablate pathogenic tissue. FUS therapy is often combined with magnetic resonance (MR) imaging as MR imaging offers excellent target identification and allows for continuous monitoring of FUS induced temperature changes. As the dimensions of the ultrasound (US) focus are typically much smaller than the targeted volume, multiple sonications and focus repositioning are interleaved to scan the focus over the target volume. Focal scanning can be achieved electronically by using phased-array US transducers or mechanically by using dedicated mechanical actuators. In this study, the authors propose and evaluate the precision of a combined robotic FUS setup to overcome some of the limitations of the existing MRgFUS systems. Such systems are typically integrated into the patient table of the MR scanner and thus only provide an application of the US wave within a limited spatial range from below the patient. The fully MR-compatible robotic assistance system InnoMotion (InnoMedic GmbH, Herxheim, Germany) was originally designed for MR-guided interventions with needles. It offers five pneumatically driven degrees of freedom and can be moved over a wide range within the bore of the magnet. In this work, the robotic system was combined with a fixed-focus US transducer (frequency: 1.7 MHz; focal length: 68 mm, and numerical aperture: 0.44) that was integrated into a dedicated, in-house developed treatment unit for FUS application. A series of MR-guided focal scanning procedures was performed in a polyacrylamide-egg white gel phantom to assess the positioning accuracy of the combined FUS setup. In animal experiments with a 3-month-old domestic pig, the system's potential and suitability for MRgFUS was tested. In phantom experiments, a total targeting precision of about 3 mm was found, which is comparable to that of the existing MRgFUS systems. Focus positioning could be performed within a few seconds

  1. MR-guided focused ultrasound: a potentially disruptive technology.

    PubMed

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  2. Evaluation of mineral oil as an acoustic coupling medium in clinical MRgFUS.

    PubMed

    Gorny, K R; Hangiandreou, N J; Hesley, G K; Felmlee, J P

    2007-01-07

    We empirically evaluate mineral oil as an alternative to the mixture of de-gassed water and ultrasound gel, which is currently used as an acoustic coupling medium in clinical magnetic resonance guided focused ultrasound (MRgFUS) treatments. The tests were performed on an ExAblate 2000 MRgFUS system (InSightec Inc., Haifa, Israel) using a clinical patient set-up. Acoustic reflections, treatment temperatures, sonication spot dimensions and position with respect to target location were measured, using both coupling media, in repeated sonications in a tissue mimicking gel phantom. In comparison with the water-gel mix, strengths of acoustic reflections from coupling layers prepared with mineral oil were on average 39% lower and the difference was found to be statistically significant (p = 3.3 x 10(-8)). The treatment temperatures were found to be statistically equivalent for both coupling media, although temperatures corresponding to mineral oil tended to be somewhat higher (on average 1.9 degrees C) and their standard deviations were reduced by about 1 degrees C. Measurements of sonication spot dimensions and positions with respect to target location did not reveal systematic differences. We conclude that mineral oil may be used as an effective non-evaporating acoustic coupling medium for clinical MRgFUS treatments.

  3. First noninvasive thermal ablation of a brain tumor with MR-guided focused ultrasound

    PubMed Central

    2014-01-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas its clinical application for tumor neurosurgery has been delayed for various technical and procedural reasons. Here, we report the case of a 63-year-old patient presenting with a centrally located recurrent glioblastoma who was included in our ongoing clinical phase I study aimed at evaluating the feasibility and safety of transcranial MRgFUS for brain tumor ablation. Applying 25 high-power sonications under MR imaging guidance, partial tumor ablation could be achieved without provoking neurological deficits or other adverse effects in the patient. This proves, for the first time, the feasibility of using transcranial MR-guided focused ultrasound to safely ablate substantial volumes of brain tumor tissue. PMID:25671132

  4. MRI-Guided Focused Ultrasound Surgery for Uterine Fibroid Treatment: A Cost-Effectiveness Analysis

    PubMed Central

    Kong, Chung Y.; Omer, Zehra B.; Pandharipande, Pari V.; Swan, J. Shannon; Srouji, Serene; Gazelle, G. Scott; Fennessy, Fiona M.

    2015-01-01

    Objective To evaluate the cost-effectiveness of a treatment strategy for symptomatic uterine fibroids that employs Magnetic Resonance guided Focused Ultrasound (MRgFUS) as a first-line therapy relative to uterine artery embolization (UAE) or abdominal hysterectomy (HYST). Materials and Methods We developed a decision-analytic model to compare the cost-effectiveness of three treatment strategies: MRgFUS, UAE and HYST. Short and long-term utilities specific to each treatment were incorporated, allowing us to account for differences in quality of life across the strategies considered. Lifetime costs and quality-adjusted life-years (QALYs) were calculated for each strategy. An incremental cost-effectiveness analysis was performed, using a societal willingness-to-pay (WTP) threshold of $50,000 per QALY to designate a strategy as cost-effective. Sensitivity analysis was performed on all key model parameters. Results In the base-case analysis, in which treatment for symptomatic fibroids started at age 40, UAE was the most effective and expensive strategy (22.81 QALYs, $22,164), followed by MRgFUS (22.80 QALYs, $19,796) and HYST (22.60 QALYs, $13,291). MRgFUS was cost-effective relative to HYST, with an associated incremental cost-effectiveness ratio (ICER) of $33,110/QALY. MRgFUS was also cost-effective relative to UAE – the ICER of UAE relative to MRgFUS ($270,057) far exceeded the WTP threshold of $50,000/QALY. In sensitivity analysis, results were robust to changes in most parameters, but were sensitive to changes in probabilities of recurrence and symptom relief following certain procedures, and quality of life associated with symptomatic fibroids. Conclusions MRgFUS is cost-effective relative to both UAE and hysterectomy for the treatment of women with symptomatic fibroids. PMID:25055272

  5. Review of MRI positioning devices for guiding focused ultrasound systems.

    PubMed

    Yiallouras, C; Damianou, C

    2015-06-01

    This article contains a review of positioning devices that are currently used in the area of magnetic resonance imaging (MRI) guided focused ultrasound surgery (MRgFUS). The paper includes an extensive review of literature published since the first prototype system was invented in 1991. The technology has grown into a fast developing area with application to any organ accessible to ultrasound. The initial design operated using hydraulic principles, while the latest technology incorporates piezoelectric motors. Although, in the beginning there were fears regarding MRI safety, during recent years, the deployment of MR-safe positioning devices in FUS has become routine. Many of these positioning devices are now undergoing testing in clinical trials. Existing MRgFUS systems have been utilized mostly in oncology (fibroids, brain, liver, kidney, bone, pancreas, eye, thyroid, and prostate). It is anticipated that, in the near future, there will be a positioning device for every organ that is accessible by focused ultrasound. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Initial evaluation of acoustic reflectors for the preservation of sensitive abdominal skin areas during MRgFUS treatment.

    PubMed

    Gorny, Krzysztof R; Chen, Shigao; Hangiandreou, Nicholas J; Hesley, Gina K; Woodrum, David A; Brown, Douglas L; Felmlee, Joel P

    2009-04-21

    During MR-guided focused ultrasound (MRgFUS) treatments of uterine fibroids using ExAblate(R)2000 (InSightec, Haifa, Israel), individual tissue ablations are performed extracorporeally through the patient's abdomen using an annular array FUS transducer embedded within the MR table. Ultrasound intensities in the near field are below therapeutic levels and, under normal conditions, heating of the patient skin is minimal. However, increased absorption of ultrasound energy within sensitive skin areas or areas with differing acoustic properties, such as scars, may lead to skin burns and therefore these areas must be kept outside the near field of the FUS beam. Depending on their location and size the sensitive areas may either obstruct parts of the fibroid from being treated or prevent the entire MRgFUS treatment altogether. The purpose of this work is to evaluate acoustic reflector materials that can be applied to protect skin and the underlying sensitive areas. Reflection coefficients of cork (0.88) and foam (0.91) based materials were evaluated with a hydrophone. An ExAblate 2000 MRgFUS system was used to simulate clinical treatment with discs of reflector materials placed in a near field underneath a gel phantom. MR thermometry was used to monitor temperature elevations as well as the integrity of the focal spot. The phantom measurements showed acoustic shadow zones behind the reflectors with zone depths changing between 7 and 27 mm, for reflector disc diameters increasing from 10 to 30 mm (40 mm diameter discs completely blocked the FUS beam at the depth evaluated). The effects on thermal lesions due to the presence of the reflectors in the FUS beam were found to diminish with decreasing disc diameter and increasing sonication depth. For a 20 mm diameter disc and beyond 50 mm sonication depth, thermal lesions were minimally affected by the presence of the disc. No heating was observed on the skin side of the foam reflectors, as confirmed by measurements performed

  7. ExAblate magnetic resonance-guided focused ultrasound system in multiple body applications.

    PubMed

    Dick, E A; Gedroyc, W M W

    2010-09-01

    Focused ultrasound surgery (FUS) is a completely noninvasive method of thermally destroying a target tissue while sparing adjacent tissues and organs. Treatment is relatively painless and can be carried out under conscious sedation on an out-patient basis. The combination of magnetic resonance guidance with FUS (MRgFUS) provides the ability to plan and monitor treatments in near real-time, further increasing the safety profile of MRgFUS. This technology provides a very personalized treatment, adjusted to the individual patient anatomy, pathology and treatment response, hence it meets the needs of patients, as well as of physicians. MRgFUS has been used extensively in the successful treatment of uterine fibroids, and has been shown to be an effective treatment in the breast and in bone metastases in smaller scale studies. It shows great potential in the treatment of prostate and liver tumors, as well as in the brain and facet joints.

  8. Quantification of intraventricular blood clot in MR-guided focused ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Hess, Maggie; Looi, Thomas; Lasso, Andras; Fichtinger, Gabor; Drake, James

    2015-03-01

    Intraventricular hemorrhage (IVH) affects nearly 15% of preterm infants. It can lead to ventricular dilation and cognitive impairment. To ablate IVH clots, MR-guided focused ultrasound surgery (MRgFUS) is investigated. This procedure requires accurate, fast and consistent quantification of ventricle and clot volumes. We developed a semi-autonomous segmentation (SAS) algorithm for measuring changes in the ventricle and clot volumes. Images are normalized, and then ventricle and clot masks are registered to the images. Voxels of the registered masks and voxels obtained by thresholding the normalized images are used as seed points for competitive region growing, which provides the final segmentation. The user selects the areas of interest for correspondence after thresholding and these selections are the final seeds for region growing. SAS was evaluated on an IVH porcine model. SAS was compared to ground truth manual segmentation (MS) for accuracy, efficiency, and consistency. Accuracy was determined by comparing clot and ventricle volumes produced by SAS and MS, and comparing contours by calculating 95% Hausdorff distances between the two labels. In Two-One-Sided Test, SAS and MS were found to be significantly equivalent (p < 0.01). SAS on average was found to be 15 times faster than MS (p < 0.01). Consistency was determined by repeated segmentation of the same image by both SAS and manual methods, SAS being significantly more consistent than MS (p < 0.05). SAS is a viable method to quantify the IVH clot and the lateral brain ventricles and it is serving in a large-scale porcine study of MRgFUS treatment of IVH clot lysis.

  9. MR-guided Focused Ultrasound for Uterine Fibroids

    MedlinePlus

    ... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...

  10. Analytical estimation of ultrasound properties, thermal diffusivity, and perfusion using magnetic resonance-guided focused ultrasound temperature data

    PubMed Central

    Dillon, C R; Borasi, G; Payne, A

    2016-01-01

    For thermal modeling to play a significant role in treatment planning, monitoring, and control of magnetic resonance-guided focused ultrasound (MRgFUS) thermal therapies, accurate knowledge of ultrasound and thermal properties is essential. This study develops a new analytical solution for the temperature change observed in MRgFUS which can be used with experimental MR temperature data to provide estimates of the ultrasound initial heating rate, Gaussian beam variance, tissue thermal diffusivity, and Pennes perfusion parameter. Simulations demonstrate that this technique provides accurate and robust property estimates that are independent of the beam size, thermal diffusivity, and perfusion levels in the presence of realistic MR noise. The technique is also demonstrated in vivo using MRgFUS heating data in rabbit back muscle. Errors in property estimates are kept less than 5% by applying a third order Taylor series approximation of the perfusion term and ensuring the ratio of the fitting time (the duration of experimental data utilized for optimization) to the perfusion time constant remains less than one. PMID:26741344

  11. Focused Ultrasound Surgery for Uterine Fibroids

    MedlinePlus

    ... ultrasound surgery, your doctor may perform a pelvic magnetic resonance imaging (MRI) scan before treatment. Focused ultrasound surgery — also called magnetic resonance-guided focused ultrasound surgery or focused ultrasound ...

  12. Scaled signal intensity of uterine fibroids based on T2-weighted MR images: a potential objective method to determine the suitability for magnetic resonance-guided focused ultrasound surgery of uterine fibroids.

    PubMed

    Park, Hyun; Yoon, Sang-Wook; Sokolov, Amit

    2015-12-01

    Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) is a non-invasive method to treat uterine fibroids. To help determine the patient suitability for MRgFUS, we propose a new objective measure: the scaled signal intensity (SSI) of uterine fibroids in T2 weighted MR images (T2WI). Forty three uterine fibroids in 40 premenopausal women were included in this retrospective study. SSI of each fibroid was measured from the screening T2WI by standardizing its mean signal intensity to a 0-100 scale, using reference intensities of rectus abdominis muscle (0) and subcutaneous fat (100). Correlation between the SSI and the non-perfused volume (NPV) ratio (a measure for treatment success) was calculated. Pre-treatment SSI showed a significant inverse-correlation with post treatment NPV ratio (p < 0.05). When dichotomizing NPV ratio at 45 %, the optimal cut off value of the SSI was found to be 16.0. A fibroid with SSI value 16.0 or less can be expected to have optimal responses. The SSI of uterine fibroids in T2WI can be suggested as an objective parameter to help in patient selection for MRgFUS. • Signal intensity of fibroid in MR images predicts treatment response to MRgFUS. • Signal intensity is standardized into scaled form using adjacent tissues as references. • Fibroids with SSI less than 16.0 are expected to have optimal responses.

  13. Magnetic Resonance-Guided Focused Ultrasound Neurosurgery for Essential Tremor: A Health Technology Assessment

    PubMed Central

    Schaink, Alexis; Li, Chunmei; Gajic-Veljanoski, Olga; Wells, David; Higgins, Caroline

    2018-01-01

    Background The standard treatment option for medication-refractory essential tremor is invasive neurosurgery. A new, noninvasive alternative is magnetic resonance-guided focused ultrasound (MRgFUS) neurosurgery. We aimed to determine the effectiveness, safety, and cost-effectiveness of MRgFUS neurosurgery for the treatment of moderate to severe, medication-refractory essential tremor in Ontario. We also spoke with people with essential tremor to gain an understanding of their experiences and thoughts regarding treatment options, including MRgFUS neurosurgery. Methods We performed a systematic review of the clinical literature published up to April 11, 2017, that examined MRgFUS neurosurgery alone or compared with other interventions for the treatment of moderate to severe, medication-refractory essential tremor. We assessed the risk of bias of each study and the quality of the body of evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. We performed a systematic review of the economic literature and created Markov cohort models to assess the cost-effectiveness of MRgFUS neurosurgery compared with other treatment options, including no surgery. We also estimated the budget impact of publicly funding MRgFUS neurosurgery in Ontario for the next 5 years. To contextualize the potential value of MRgFUS neurosurgery as a treatment option for essential tremor, we spoke with people with essential tremor and their families. Results Nine studies met our inclusion criteria for the clinical evidence review. In noncomparative studies, MRgFUS neurosurgery was found to significantly improve tremor severity and quality of life and to significantly reduce functional disability (GRADE: very low). It was also found to be significantly more effective than a sham procedure (GRADE: high). We found no significant difference in improvements in tremor severity, functional disability, or quality of life between MRgFUS

  14. Workflow and intervention times of MR-guided focused ultrasound - Predicting the impact of new techniques.

    PubMed

    Loeve, Arjo J; Al-Issawi, Jumana; Fernandez-Gutiérrez, Fabiola; Langø, Thomas; Strehlow, Jan; Haase, Sabrina; Matzko, Matthias; Napoli, Alessandro; Melzer, Andreas; Dankelman, Jenny

    2016-04-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) has become an attractive, non-invasive treatment for benign and malignant tumours, and offers specific benefits for poorly accessible locations in the liver. However, the presence of the ribcage and the occurrence of liver motion due to respiration limit the applicability MRgFUS. Several techniques are being developed to address these issues or to decrease treatment times in other ways. However, the potential benefit of such improvements has not been quantified. In this research, the detailed workflow of current MRgFUS procedures was determined qualitatively and quantitatively by using observation studies on uterine MRgFUS interventions, and the bottlenecks in MRgFUS were identified. A validated simulation model based on discrete events simulation was developed to quantitatively predict the effect of new technological developments on the intervention duration of MRgFUS on the liver. During the observation studies, the duration and occurrence frequencies of all actions and decisions in the MRgFUS workflow were registered, as were the occurrence frequencies of motion detections and intervention halts. The observation results show that current MRgFUS uterine interventions take on average 213min. Organ motion was detected on average 2.9 times per intervention, of which on average 1.0 actually caused a need for rework. Nevertheless, these motion occurrences and the actions required to continue after their detection consumed on average 11% and up to 29% of the total intervention duration. The simulation results suggest that, depending on the motion occurrence frequency, the addition of new technology to automate currently manual MRgFUS tasks and motion compensation could potentially reduce the intervention durations by 98.4% (from 256h 5min to 4h 4min) in the case of 90% motion occurrence, and with 24% (from 5h 19min to 4h 2min) in the case of no motion. In conclusion, new tools were developed to predict how

  15. Combined Ultrasound and MR Imaging to Guide Focused Ultrasound Therapies in the Brain

    PubMed Central

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-01-01

    Purpose Several emerging therapies with potential for use in the brain harness effects produced by acoustic cavitation – the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength, and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. Materials and Methods We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. Results The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. Conclusion While preliminary, these data clearly demonstrate, for the first time, that is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate it will also prove to

  16. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    NASA Astrophysics Data System (ADS)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  17. [Magnetic resonance guided focused ultrasound surgery for pain palliation of bone metastases: early experience of clinical application in China].

    PubMed

    Gu, Jianjun; Wang, Han; Tang, Na; Hua, Yingqi; Yang, Haiyan; Qiu, Yimin; Ge, Renbin; Zhou, Ying; Wang, Wenwen; Zhang, Guixiang

    2015-11-03

    To evaluate the safety and efficacy of magnetic resonance guided focused ultrasound surgery (MRgFUS) in treatment for pain palliation of bone metastases. Eighty-one patients of painful bone metastases were volunteered to screen for this study in Shanghai General Hospital from June 2014 to February 2015. Twenty-three patients among them were treated by MRgFUS, who was more than 18-years old, having the ability to fully understand the informed consent of the research, suffering with pain of numeric rating scale (NRS) ≥ 4, non-received radiotherapy or chemotherapy for pain palliation of bone metastases in the past two weeks. The NRS, the standard question of Brief Pain Inventory (BPI-QoL), and the standard question of Europe Organization for Research and Treatment of Cancer Quality of Life Questionnaire- Bone Metastases 22 (EORTC QLQ-BM22) were respectively recorded before and 1-week, 1-month, 3-month after the treatment. The related adverse events of MRgFUS were observed and recorded in 3 months after the treatment as well. (1)Twenty-three metastatic bone tumor lesions of 23 patients were treated by MRgFUS, the treatment data was as follows: the mean treatment time was (88 ± 33) minutes, the mean sonication number was 13 ± 8. (2) Adverse events included: pain in therapy area 3/23, which spontaneous relieving within one week; numbness in lower limb (1/23), which relieved after physiotherapy. (3) The NRS of before treatment and at 1-week, 1-month, and 3-month after treatment respectively was 6.0 ± 1.5, 3.7 ± 1.7,3.1 ± 2.0, and 2.2 ± 1.0,which significantly decreased after the treatment (P<0.01). (4) The BPI-QoL score of before treatment and at 1-week, 1-month, and 3-month after treatment respectively was 39 ± 16, 27 ± 18, 26 ± 18, and 21 ± 18, which significantly decreased after the treatment (P<0.01). (5) The EORTC QLQ-BM22 score of before treatment and at 1-week, 1-month, and 3-month after treatment respectively was 52 ± 13, 44 ± 12, 42 ± 12, and 39

  18. MRI predictors of clinical success in MR-guided focused ultrasound (MRgFUS) treatments of uterine fibroids: results from a single centre.

    PubMed

    Mindjuk, Irene; Trumm, Christoph G; Herzog, Peter; Stahl, Robert; Matzko, Matthias

    2015-05-01

    To assess the technical and clinical results of MRgFUS treatment and factors affecting clinical treatment success. A total of 252 women (mean age, 42.1 ± 6.9 years) with uterine fibroids underwent MRgFUS. All patients underwent MRI before treatment. Results were evaluated with respect to post-treatment nonperfused volume (NPV), symptom severity score (SSS), reintervention rate, pregnancy and safety data. NPV ratio was significantly higher in fibroids characterized by low signal intensity in contrast-enhanced T1-weighted fat saturated MR images and in fibroids distant from the spine (>3 cm). NPV ratio was lower in fibroids with septations, with subserosal component and in skin-distant fibroids (p < 0.001). NPV ratio was highly correlated with clinical success: NPV of more than 80 % resulted in clinical success in more than 80 % of patients. Reintervention rate was 12.7 % (mean follow-up time, 19.4 ± 8 months; range, 3-38). Expulsion of fibroids (21 %) was significantly correlated with a high clinical success rate. No severe adverse events were reported. Adequate patient selection and correct treatment techniques, based on the learning curve of this technology, combined with technical advances of the system, lead to higher clinical success rates with low complications rate, comparable to other uterine-sparing treatment options. • MRgFUS appears to be a valid alternative to other uterus-preserving therapies • Patient selection is a significant factor in achieving high NPV ratios • MRI screening parameters correlate with the amount of fibroid ablation in MRgFUS • NPV results of more than 80 % correlate with higher clinical success rates.

  19. MR guided FUS therapy with a Robotic Assistance System

    NASA Astrophysics Data System (ADS)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael

    2009-04-01

    Magnetic Resonance imaging guided Focus Ultrasound Surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. To date, there is only one commercial MRgFUS system available and only a few are in a prototype stage. The objective of this ongoing project is to establish an MRgFUS therapy unit as add-on for a commercially available robotic assistance system originally designed for percutaneous needle interventions in whole-body MR scanners.

  20. Phase aberration simulation study of MRgFUS breast treatments

    PubMed Central

    Farrer, Alexis I.; Almquist, Scott; Dillon, Christopher R.; Neumayer, Leigh A.; Parker, Dennis L.; Christensen, Douglas A.; Payne, Allison

    2016-01-01

    Purpose: This simulation study evaluates the effects of phase aberration in breast MR-guided focused ultrasound (MRgFUS) ablation treatments performed with a phased-array transducer positioned laterally to the breast. A quantification of these effects in terms of thermal dose delivery and the potential benefits of phase correction is demonstrated in four heterogeneous breast numerical models. Methods: To evaluate the effects of varying breast tissue properties on the quality of the focus, four female volunteers with confirmed benign fibroadenomas were imaged using 3T MRI. These images were segmented into numerical models with six tissue types, with each tissue type assigned standard acoustic properties from the literature. Simulations for a single-plane 16-point raster-scan treatment trajectory centered in a fibroadenoma in each modeled breast were performed for a breast-specific MRgFUS system. At each of the 16 points, pressure patterns both with and without applying a phase correction technique were determined with the hybrid-angular spectrum method. Corrected phase patterns were obtained using a simulation-based phase aberration correction technique to adjust each element’s transmit phase to obtain maximized constructive interference at the desired focus. Thermal simulations were performed for both the corrected and uncorrected pressure patterns using a finite-difference implementation of the Pennes bioheat equation. The effect of phase correction was evaluated through comparison of thermal dose accumulation both within and outside a defined treatment volume. Treatment results using corrected and uncorrected phase aberration simulations were compared by evaluating the power required to achieve a 20 °C temperature rise at the first treatment location. The extent of the volumes that received a minimum thermal dose of 240 CEM at 43 °C inside the intended treatment volume as well as the volume in the remaining breast tissues was also evaluated in the form of

  1. Magnetic resonance-guided focused ultrasound treatment of facet joint pain: summary of preclinical phase

    PubMed Central

    2014-01-01

    Study design A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted to test the feasibility, safety, and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for treating facet joint pain. Objective The goal of the current study was to develop a novel method for accurate and safe noninvasive facet joint ablation using MRgFUS. Summary of background data Facet joints are a common source of chronic back pain. Direct facet joint interventions include medial branch nerve ablation and intra-articular injections, which are widely used, but limited in the short and long term. MRgFUS is a breakthrough technology that enables accurate delivery of high-intensity focused ultrasound energy to create a localized temperature rise for tissue ablation, using MR guidance for treatment planning and real-time feedback. Methods We validated the feasibility, safety, and efficacy of MRgFUS for facet joint ablation using the ExAblate 2000® System (InSightec Ltd., Tirat Carmel, Israel) and confirmed the system's ability to ablate the edge of the facet joint and all terminal nerves innervating the joint. A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted. Results The experiments showed that targeting the facet joint with energies of 150–450 J provides controlled and accurate heating at the facet joint edge without penetration to the vertebral body, spinal canal, or root foramina. Treating with reduced diameter of the acoustic beam is recommended since a narrower beam improves access to the targeted areas. Conclusions MRgFUS can safely and effectively target and ablate the facet joint. These results are highly significant, given that this is the first study to demonstrate the potential of MRgFUS to treat facet joint pain. PMID:24921048

  2. Factors associated with successful magnetic resonance-guided focused ultrasound treatment: efficiency of acoustic energy delivery through the skull.

    PubMed

    Chang, Won Seok; Jung, Hyun Ho; Zadicario, Eyal; Rachmilevitch, Itay; Tlusty, Tal; Vitek, Shuki; Chang, Jin Woo

    2016-02-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) was recently introduced as treatment for movement disorders such as essential tremor and advanced Parkinson's disease (PD). Although deep brain target lesions are successfully generated in most patients, the target area temperature fails to increase in some cases. The skull is one of the greatest barriers to ultrasonic energy transmission. The authors analyzed the skull-related factors that may have prevented an increase in target area temperatures in patients who underwent MRgFUS. The authors retrospectively reviewed data from clinical trials that involved MRgFUS for essential tremor, idiopathic PD, and obsessive-compulsive disorder. Data from 25 patients were included. The relationships between the maximal temperature during treatment and other factors, including sex, age, skull area of the sonication field, number of elements used, skull volume of the sonication field, and skull density ratio (SDR), were determined. Among the various factors, skull volume and SDR exhibited relationships with the maximum temperature. Skull volume was negatively correlated with maximal temperature (p = 0.023, r(2) = 0.206, y = 64.156 - 0.028x, whereas SDR was positively correlated with maximal temperature (p = 0.009, r(2) = 0.263, y = 49.643 + 11.832x). The other factors correlate with the maximal temperature, although some factors showed a tendency to correlate. Some skull-related factors correlated with the maximal target area temperature. Although the number of patients in the present study was relatively small, the results offer information that could guide the selection of MRgFUS candidates.

  3. Acoustic characterization of Thiel liver for magnetic resonance-guided focused ultrasound treatment.

    PubMed

    Karakitsios, Ioannis; Joy, Joyce; Mihcin, Senay; Melzer, Andreas

    2017-04-01

    The purpose of this work was to measure the essential acoustic parameters, i.e., acoustic impedance, reflection coefficient, attenuation coefficient, of Thiel embalmed human and animal liver. The Thiel embalmed tissue can be a promising, pre-clinical model to study liver treatment with Magnetic Resonance-guided Focused Ultrasound (MRgFUS). Using a single-element transducer and the contact pulse-echo method, the acoustic parameters, i.e., acoustic impedance, reflection coefficient and attenuation coefficient of Thiel embalmed human and animal liver were measured. The Thiel embalmed livers had higher impedance, similar reflection and lower attenuation compared to the fresh tissue. Embalming liver with Thiel fluid affects its acoustic properties. During MRgFUS sonication of a Thiel organ, more focused ultrasound (FUS) will be backscattered by the organ, and higher acoustic powers are required to reach coagulation levels (temperatures >56 °C).

  4. Enhanced Delivery of Gold Nanoparticles with Therapeutic Potential into the Brain using MRI-Guided Focused Ultrasound

    PubMed Central

    Etame, Arnold B.; Diaz, Roberto J.; O’Reilly, Meaghan A.; Smith, Christian A.; Mainprize, Todd G.; Hynynen, Kullervo; Rutka, James T.

    2014-01-01

    The blood brain barrier (BBB) is a major impediment to the delivery of therapeutics into the central nervous system (CNS). Gold nanoparticles (AuNPs) have been successfully employed in multiple potential therapeutic and diagnostic applications outside the CNS. However, AuNPs have very limited biodistribution within the CNS following intravenous administration. Magnetic resonance imaging guided focused ultrasound (MRgFUS) is a novel technique that can transiently increase BBB permeability allowing delivery of therapeutics into the CNS. MRgFUS has not been previously employed for delivery of AuNPs into the CNS. This work represents the first demonstration of focal enhanced delivery of AuNPs into the CNS using MRgFUS in a rat model both safely and effectively. Histologic visualization and analytical quantification of AuNPs within the brain parenchyma suggest BBB transgression. These results suggest a role for MRgFUS in the delivery of AuNPs with therapeutic potential into the CNS for targeting neurological diseases. PMID:22349099

  5. Application of Zernike polynomials towards accelerated adaptive focusing of transcranial high intensity focused ultrasound.

    PubMed

    Kaye, Elena A; Hertzberg, Yoni; Marx, Michael; Werner, Beat; Navon, Gil; Levoy, Marc; Pauly, Kim Butts

    2012-10-01

    To study the phase aberrations produced by human skulls during transcranial magnetic resonance imaging guided focused ultrasound surgery (MRgFUS), to demonstrate the potential of Zernike polynomials (ZPs) to accelerate the adaptive focusing process, and to investigate the benefits of using phase corrections obtained in previous studies to provide the initial guess for correction of a new data set. The five phase aberration data sets, analyzed here, were calculated based on preoperative computerized tomography (CT) images of the head obtained during previous transcranial MRgFUS treatments performed using a clinical prototype hemispherical transducer. The noniterative adaptive focusing algorithm [Larrat et al., "MR-guided adaptive focusing of ultrasound," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57(8), 1734-1747 (2010)] was modified by replacing Hadamard encoding with Zernike encoding. The algorithm was tested in simulations to correct the patients' phase aberrations. MR acoustic radiation force imaging (MR-ARFI) was used to visualize the effect of the phase aberration correction on the focusing of a hemispherical transducer. In addition, two methods for constructing initial phase correction estimate based on previous patient's data were investigated. The benefits of the initial estimates in the Zernike-based algorithm were analyzed by measuring their effect on the ultrasound intensity at the focus and on the number of ZP modes necessary to achieve 90% of the intensity of the nonaberrated case. Covariance of the pairs of the phase aberrations data sets showed high correlation between aberration data of several patients and suggested that subgroups can be based on level of correlation. Simulation of the Zernike-based algorithm demonstrated the overall greater correction effectiveness of the low modes of ZPs. The focal intensity achieves 90% of nonaberrated intensity using fewer than 170 modes of ZPs. The initial estimates based on using the average of the

  6. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies

    PubMed Central

    Arvanitis, Costas D.; McDannold, Nathan

    2013-01-01

    Purpose: Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. Methods: The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30–110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. Results: When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was −3.4 ± 2.1 mm and −0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small

  7. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

    PubMed

    Arvanitis, Costas D; McDannold, Nathan

    2013-11-01

    Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30-110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was -3.4 ± 2.1 mm and -0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small uncertainties in the PAM

  8. MR-guided transcranial focused ultrasound safely enhances interstitial dispersion of large polymeric nanoparticles in the living brain

    PubMed Central

    Mohammadabadi, Ali; Nguyen, Ben A.; Guo, Sijia; Winkles, Jeffrey A.; Kim, Anthony J.; Gullapalli, Rao; Keller, Asaf; Frenkel, Victor

    2018-01-01

    Generating spatially controlled, non-destructive changes in the interstitial spaces of the brain has a host of potential clinical applications, including enhancing the delivery of therapeutics, modulating biological features within the tissue microenvironment, altering fluid and pressure dynamics, and increasing the clearance of toxins, such as plaques found in Alzheimer’s disease. Recently we demonstrated that ultrasound can non-destructively enlarge the interstitial spaces of the brain ex vivo. The goal of the current study was to determine whether these effects could be reproduced in the living brain using non-invasive, transcranial MRI-guided focused ultrasound (MRgFUS). The left striatum of healthy rats was treated using MRgFUS. Computer simulations facilitated treatment planning, and targeting was validated using MRI acoustic radiation force impulse imaging. Following MRgFUS treatments, Evans blue dye or nanoparticle probes were infused to assess changes in the interstitial space. In MRgFUS-treated animals, enhanced dispersion was observed compared to controls for 70 nm (12.8 ± 0.9 mm3 vs. 10.6 ± 1.0 mm3, p = 0.01), 200 nm (10.9 ± 1.4 mm3 vs. 7.4 ± 0.7 mm3, p = 0.01) and 700 nm (7.5 ± 0.4 mm3 vs. 5.4 ± 1.2 mm3, p = 0.02) nanoparticles, indicating enlargement of the interstitial spaces. No evidence of significant histological or electrophysiological injury was identified. These findings suggest that transcranial ultrasound can safely and effectively modulate the brain interstitium and increase the dispersion of large therapeutic entities such as particulate drug carriers or modified viruses. This has the potential to expand the therapeutic uses of MRgFUS. PMID:29415084

  9. Ultrasound ablation enhances drug accumulation and survival in mammary carcinoma models.

    PubMed

    Wong, Andrew W; Fite, Brett Z; Liu, Yu; Kheirolomoom, Azadeh; Seo, Jai W; Watson, Katherine D; Mahakian, Lisa M; Tam, Sarah M; Zhang, Hua; Foiret, Josquin; Borowsky, Alexander D; Ferrara, Katherine W

    2016-01-01

    Magnetic resonance-guided focused ultrasound (MRgFUS) facilitates noninvasive image-guided conformal thermal therapy of cancer. Yet in many scenarios, the sensitive tissues surrounding the tumor constrain the margins of ablation; therefore, augmentation of MRgFUS with chemotherapy may be required to destroy remaining tumor. Here, we used 64Cu-PET-CT, MRI, autoradiography, and fluorescence imaging to track the kinetics of long-circulating liposomes in immunocompetent mammary carcinoma-bearing FVB/n and BALB/c mice. We observed a 5-fold and 50-fold enhancement of liposome and drug concentration, respectively, within MRgFUS thermal ablation-treated tumors along with dense accumulation within the surrounding tissue rim. Ultrasound-enhanced drug accumulation was rapid and durable and greatly increased total tumor drug exposure over time. In addition, we found that the small molecule gadoteridol accumulates around and within ablated tissue. We further demonstrated that dilated vasculature, loss of vascular integrity resulting in extravasation of blood cells, stromal inflammation, and loss of cell-cell adhesion and tissue architecture all contribute to the enhanced accumulation of the liposomes and small molecule probe. The locally enhanced liposome accumulation was preserved even after a multiweek protocol of doxorubicin-loaded liposomes and partial ablation. Finally, by supplementing ablation with concurrent liposomal drug therapy, a complete and durable response was obtained using protocols for which a sub-mm rim of tumor remained after ablation.

  10. Ultrasound ablation enhances drug accumulation and survival in mammary carcinoma models

    PubMed Central

    Wong, Andrew W.; Fite, Brett Z.; Liu, Yu; Kheirolomoom, Azadeh; Seo, Jai W.; Watson, Katherine D.; Mahakian, Lisa M.; Tam, Sarah M.; Zhang, Hua; Foiret, Josquin; Borowsky, Alexander D.; Ferrara, Katherine W.

    2015-01-01

    Magnetic resonance–guided focused ultrasound (MRgFUS) facilitates noninvasive image-guided conformal thermal therapy of cancer. Yet in many scenarios, the sensitive tissues surrounding the tumor constrain the margins of ablation; therefore, augmentation of MRgFUS with chemotherapy may be required to destroy remaining tumor. Here, we used 64Cu-PET-CT, MRI, autoradiography, and fluorescence imaging to track the kinetics of long-circulating liposomes in immunocompetent mammary carcinoma–bearing FVB/n and BALB/c mice. We observed a 5-fold and 50-fold enhancement of liposome and drug concentration, respectively, within MRgFUS thermal ablation–treated tumors along with dense accumulation within the surrounding tissue rim. Ultrasound-enhanced drug accumulation was rapid and durable and greatly increased total tumor drug exposure over time. In addition, we found that the small molecule gadoteridol accumulates around and within ablated tissue. We further demonstrated that dilated vasculature, loss of vascular integrity resulting in extravasation of blood cells, stromal inflammation, and loss of cell-cell adhesion and tissue architecture all contribute to the enhanced accumulation of the liposomes and small molecule probe. The locally enhanced liposome accumulation was preserved even after a multiweek protocol of doxorubicin-loaded liposomes and partial ablation. Finally, by supplementing ablation with concurrent liposomal drug therapy, a complete and durable response was obtained using protocols for which a sub-mm rim of tumor remained after ablation. PMID:26595815

  11. MRI monitoring of focused ultrasound sonications near metallic hardware.

    PubMed

    Weber, Hans; Ghanouni, Pejman; Pascal-Tenorio, Aurea; Pauly, Kim Butts; Hargreaves, Brian A

    2018-07-01

    To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. 2DMSI was optimized for temperature sensitivity and applied to monitor focus ultrasound surgery (FUS) sonications near metallic hardware in phantoms and ex vivo porcine muscle tissue. Further, we evaluated its temperature sensitivity for in vivo muscle in patients without metallic hardware. In addition, we performed a comparison of temperature sensitivity between 2DMSI and conventional proton-resonance-frequency-shift (PRFS) thermometry at different distances from metal devices and different signal-to-noise ratios (SNR). 2DMSI thermometry enabled visualization of short ultrasound sonications near metallic hardware. Calibration using in vivo muscle yielded a constant temperature sensitivity for temperatures below 43 °C. For an off-resonance coverage of ± 6 kHz, we achieved a temperature sensitivity of 1.45%/K, resulting in a minimum detectable temperature change of ∼2.5 K for an SNR of 100 with a temporal resolution of 6 s per frame. The proposed 2DMSI thermometry has the potential to allow MR-guided FUS treatments of patients with metallic hardware and therefore expand its reach to a larger patient population. Magn Reson Med 80:259-271, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. MRI-guided Focused Ultrasound Ablation of Lumbar Medial Branch Nerve: Feasibility and Safety Study in a Swine Model

    PubMed Central

    Kaye, Elena A; Monette, Sebastien; Srimathveeravalli, Govindarajan; Maybody, Majid; Solomon, Stephen B; Gulati, Amitabh

    2016-01-01

    Purpose About 10–40% of chronic low back pain cases involve facet joints, which are commonly treated with lumbar medial branch (MB) radiofrequency neurotomy. Magnetic Resonance Imaging-guided Focused Ultrasound (MRgFUS), a non-invasive, non-ionizing ablation modality used to treat tumors, neuropathic pain and painful bone metastasis, can also be used to disrupt nerve conduction. This work’s purpose was to study the feasibility and safety of direct MRgFUS ablation of the lumbar MB nerve in acute and subacute swine models. Materials and Methods In vivo MRgFUS ablation was performed in six swine (3 acute and 3 subacute) using a clinical MRgFUS system (ExAblate 2000®; InSightec Ltd., Haifa, Israel) and 3 T MRI scanner (SIGNA; GE Healthcare, Waukesha, WI, USA) combination. Behavioral assessment was performed, and imaging and histology were used to assess the treatment. Results and Conclusions Histological analysis of the in vivo studies confirmed thermal necrosis of the MB nerve could be achieved without damaging the spinal cord or adjacent nerve roots. MRgFUS did not cause changes in the animals’ behavior and ambulation. PMID:27443328

  13. [Ultrasound-guided rectus sheath block for upper abdominal surgery].

    PubMed

    Osaka, Yoshimune; Kashiwagi, Masanori; Nagatsuka, Yukio; Oosaku, Masayoshi; Hirose, Chikako

    2010-08-01

    Upper abdominal surgery leads to severe postoperative pain. Insufficient postoperative analgesia accompanies a high incidence of complications. Therefore, postoperative analgesia is very important. The epidural analgesia has many advantages. However it has a high risk of epidural hematoma in anticoagulated patients. Rectus sheath block provided safer and more reliable analgesia in recent years, by the development of ultrasound tools. We experienced two cases of the rectus sheath block in upper abdominal surgery under ultrasound guidance. Ultrasound guided rectus sheath block can reduce the risk of peritoneal puncture, bleeding, and other complications. Rectus sheath block is very effective to reduce postoperative pain in upper abdominal surgery as an alternative method to epidural anesthesia in anticoagulated patients.

  14. [MR-guided focused ultrasound. Current and future applications].

    PubMed

    Trumm, C G; Napoli, A; Peller, M; Clevert, D-A; Stahl, R; Reiser, M; Matzko, M

    2013-03-01

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier.

  15. Intracranial inertial cavitation threshold and thermal ablation lesion creation using MRI-guided 220-kHz focused ultrasound surgery: preclinical investigation.

    PubMed

    Xu, Zhiyuan; Carlson, Carissa; Snell, John; Eames, Matt; Hananel, Arik; Lopes, M Beatriz; Raghavan, Prashant; Lee, Cheng-Chia; Yen, Chun-Po; Schlesinger, David; Kassell, Neal F; Aubry, Jean-Francois; Sheehan, Jason

    2015-01-01

    In biological tissues, it is known that the creation of gas bubbles (cavitation) during ultrasound exposure is more likely to occur at lower rather than higher frequencies. Upon collapsing, such bubbles can induce hemorrhage. Thus, acoustic inertial cavitation secondary to a 220-kHz MRI-guided focused ultrasound (MRgFUS) surgery is a serious safety issue, and animal studies are mandatory for laying the groundwork for the use of low-frequency systems in future clinical trials. The authors investigate here the in vivo potential thresholds of MRgFUS-induced inertial cavitation and MRgFUS-induced thermal coagulation using MRI, acoustic spectroscopy, and histology. Ten female piglets that had undergone a craniectomy were sonicated using a 220-kHz transcranial MRgFUS system over an acoustic energy range of 5600-14,000 J. For each piglet, a long-duration sonication (40-second duration) was performed on the right thalamus, and a short sonication (20-second duration) was performed on the left thalamus. An acoustic power range of 140-300 W was used for long-duration sonications and 300-700 W for short-duration sonications. Signals collected by 2 passive cavitation detectors were stored in memory during each sonication, and any subsequent cavitation activity was integrated within the bandwidth of the detectors. Real-time 2D MR thermometry was performed during the sonications. T1-weighted, T2-weighted, gradient-recalled echo, and diffusion-weighted imaging MRI was performed after treatment to assess the lesions. The piglets were killed immediately after the last series of posttreatment MR images were obtained. Their brains were harvested, and histological examinations were then performed to further evaluate the lesions. Two types of lesions were induced: thermal ablation lesions, as evidenced by an acute ischemic infarction on MRI and histology, and hemorrhagic lesions, associated with inertial cavitation. Passive cavitation signals exhibited 3 main patterns identified as

  16. MRI-guided focused ultrasound thalamotomy in non-ET tremor syndromes.

    PubMed

    Fasano, Alfonso; Llinas, Maheleth; Munhoz, Renato P; Hlasny, Eugen; Kucharczyk, Walter; Lozano, Andres M

    2017-08-22

    To report the 6-month single-blinded results of unilateral thalamotomy with MRI-guided focused ultrasound (MRgFUS) in patients with tremors other than essential tremor. Three patients with tremor due to Parkinson disease, 2 with dystonic tremor in the context of cervicobrachial dystonia and writer's cramp, and 1 with dystonia gene-associated tremor underwent MRgFUS targeting the ventro-intermedius nucleus (Vim) of the dominant hemisphere. The primary endpoint was the reduction of lateralized items of the Tremor Rating Scale of contralateral hemibody assessed by a blinded rater. All patients achieved a statistically significant, immediate, and sustained improvement of the contralateral tremor score by 42.2%, 52.0%, 55.9%, and 52.9% at 1 week and 1, 3, and 6 months after the procedure, respectively. All patients experienced transient side effects and 2 patients experienced persistent side effects at the time of last evaluation: hemitongue numbness and hemiparesis with hemihypoesthesia. Vim MRgFUS is a promising, incision-free, but nevertheless invasive technique to effectively treat tremors other than essential tremor. Future studies on larger samples and longer follow-up will further define its effectiveness and safety. NCT02252380. This study provides Class IV evidence that for patients with tremor not caused by essential tremor, MRgFUS of the Vim improves the tremor of the contralateral hemibody at 6 months. © 2017 American Academy of Neurology.

  17. Application of Zernike polynomials towards accelerated adaptive focusing of transcranial high intensity focused ultrasound

    PubMed Central

    Kaye, Elena A.; Hertzberg, Yoni; Marx, Michael; Werner, Beat; Navon, Gil; Levoy, Marc; Pauly, Kim Butts

    2012-01-01

    Purpose: To study the phase aberrations produced by human skulls during transcranial magnetic resonance imaging guided focused ultrasound surgery (MRgFUS), to demonstrate the potential of Zernike polynomials (ZPs) to accelerate the adaptive focusing process, and to investigate the benefits of using phase corrections obtained in previous studies to provide the initial guess for correction of a new data set. Methods: The five phase aberration data sets, analyzed here, were calculated based on preoperative computerized tomography (CT) images of the head obtained during previous transcranial MRgFUS treatments performed using a clinical prototype hemispherical transducer. The noniterative adaptive focusing algorithm [Larrat , “MR-guided adaptive focusing of ultrasound,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57(8), 1734–1747 (2010)]10.1109/TUFFC.2010.1612 was modified by replacing Hadamard encoding with Zernike encoding. The algorithm was tested in simulations to correct the patients’ phase aberrations. MR acoustic radiation force imaging (MR-ARFI) was used to visualize the effect of the phase aberration correction on the focusing of a hemispherical transducer. In addition, two methods for constructing initial phase correction estimate based on previous patient's data were investigated. The benefits of the initial estimates in the Zernike-based algorithm were analyzed by measuring their effect on the ultrasound intensity at the focus and on the number of ZP modes necessary to achieve 90% of the intensity of the nonaberrated case. Results: Covariance of the pairs of the phase aberrations data sets showed high correlation between aberration data of several patients and suggested that subgroups can be based on level of correlation. Simulation of the Zernike-based algorithm demonstrated the overall greater correction effectiveness of the low modes of ZPs. The focal intensity achieves 90% of nonaberrated intensity using fewer than 170 modes of ZPs. The

  18. TU-G-210-03: Acoustic Simulations in Transcranial MRgFUS: Treatment Prediction and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vyas, U.

    Modeling can play a vital role in predicting, optimizing and analyzing the results of therapeutic ultrasound treatments. Simulating the propagating acoustic beam in various targeted regions of the body allows for the prediction of the resulting power deposition and temperature profiles. In this session we will apply various modeling approaches to breast, abdominal organ and brain treatments. Of particular interest is the effectiveness of procedures for correcting for phase aberrations caused by intervening irregular tissues, such as the skull in transcranial applications or inhomogeneous breast tissues. Also described are methods to compensate for motion in targeted abdominal organs such asmore » the liver or kidney. Douglas Christensen – Modeling for Breast and Brain HIFU Treatment Planning Tobias Preusser – TRANS-FUSIMO - An Integrative Approach to Model-Based Treatment Planning of Liver FUS Urvi Vyas – Acoustic Simulations in Transcranial MRgFUS: Treatment Prediction and Analysis Learning Objectives: Understand the role of acoustic beam modeling for predicting the effectiveness of therapeutic ultrasound treatments. Apply acoustic modeling to specific breast, liver, kidney and transcranial anatomies. Determine how to obtain appropriate acoustic modeling parameters from clinical images. Understand the separate role of absorption and scattering in energy delivery to tissues. See how organ motion can be compensated for in ultrasound therapies. Compare simulated data with clinical temperature measurements in transcranial applications. Supported by NIH R01 HL172787 and R01 EB013433 (DC); EU Seventh Framework Programme (FP7/2007-2013) under 270186 (FUSIMO) and 611889 (TRANS-FUSIMO)(TP); and P01 CA159992, GE, FUSF and InSightec (UV)« less

  19. Investigation of standing wave formation in a human skull for a clinical prototype of a large-aperture, transcranial MR-guided Focused Ultrasound (MRgFUS) phased array: An experimental and simulation study

    PubMed Central

    Song, Junho; Pulkkinen, Aki; Huang, Yuexi; Hynynen, Kullervo

    2014-01-01

    Standing wave formation in an ex vivo human skull was investigated using a clinical prototype of a 30 cm diameter with 15 cm radius of curvature, low frequency (230 kHz), hemispherical transcranial Magnetic Resonance guided Focused Ultrasound (MRgFUS) phased-array. Experimental and simulation studies were conducted with changing aperture size and f-number configurations of the phased array, and qualitatively and quantitatively examined the acoustic pressure variation at the focus due to standing waves. The results demonstrated that the nodes and anti-nodes of standing wave produced by the small aperture array were clearly seen at approximately every 3 mm. The effect of the standing wave became more pronounced as the focus was moved closer to skull base. However, a sharp focus was seen for the full array, and there was no such standing wave pattern in the acoustic plane or near the skull base. This study showed that the fluctuation pressure amplitude would be greatly reduced by using a large-scale, hemispherical phased array with a low f-number. PMID:22049360

  20. Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays

    DTIC Science & Technology

    2001-10-25

    81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased

  1. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    PubMed

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  2. Brainstem blood brain barrier disruption using focused ultrasound: A demonstration of feasibility and enhanced doxorubicin delivery.

    PubMed

    Alli, Saira; Figueiredo, Carlyn A; Golbourn, Brian; Sabha, Nesrin; Wu, Megan Yijun; Bondoc, Andrew; Luck, Amanda; Coluccia, Daniel; Maslink, Colin; Smith, Christian; Wurdak, Heiko; Hynynen, Kullervo; O'Reilly, Meaghan; Rutka, James T

    2018-05-15

    Magnetic Resonance Image-guided Focused Ultrasound (MRgFUS) has been used to achieve transient blood brain barrier (BBB) opening without tissue injury. Delivery of a targeted ultrasonic wave causes an interaction between administered microbubbles and the capillary bed resulting in enhanced vessel permeability. The use of MRgFUS in the brainstem has not previously been shown but could provide value in the treatment of tumours such as Diffuse Intrinsic Pontine Glioma (DIPG) where the intact BBB has contributed to the limited success of chemotherapy. Our primary objective was to determine whether the use of MRgFUS in this eloquent brain region could be performed without histological injury and functional deficits. Our secondary objective was to select an effective chemotherapeutic against patient derived DIPG cell lines and demonstrate enhanced brainstem delivery when combined with MRgFUS in vivo. Female Sprague Dawley rats were randomised to one of four groups: 1) Microbubble administration but no MRgFUS treatment; 2) MRgFUS only; 3) MRgFUS + microbubbles; and 4) MRgFUS + microbubbles + cisplatin. Physiological assessment was performed by monitoring of heart and respiratory rates. Motor function and co-ordination were evaluated by Rotarod and grip strength testing. Histological analysis for haemorrhage (H&E), neuronal nuclei (NeuN) and apoptosis (cleaved Caspase-3) was also performed. A drug screen of eight chemotherapy agents was conducted in three patient-derived DIPG cell lines (SU-DIPG IV, SU-DIPG XIII and SU-DIPG XVII). Doxorubicin was identified as an effective agent. NOD/SCID/GAMMA (NSG) mice were subsequently administered with 5 mg/kg of intravenous doxorubicin at the time of one of the following: 1) Microbubbles but no MRgFUS; 2) MRgFUS only; 3) MRgFUS + microbubbles and 4) no intervention. Brain specimens were extracted at 2 h and doxorubicin quantification was conducted using liquid chromatography mass spectrometry (LC/MS). BBB opening was

  3. A software tool for advanced MRgFUS prostate therapy planning and follow up

    NASA Astrophysics Data System (ADS)

    van Straaten, Dörte; Hoogenboom, Martijn; van Amerongen, Martinus J.; Weiler, Florian; Issawi, Jumana Al; Günther, Matthias; Fütterer, Jurgen; Jenne, Jürgen W.

    2017-03-01

    US guided HIFU/FUS ablation for the therapy of prostate cancer is a clinical established method, while MR guided HIFU/FUS applications for prostate recently started clinical evaluation. Even if MRI examination is an excellent diagnostic tool for prostate cancer, it is a time consuming procedure and not practicable within an MRgFUS therapy session. The aim of our ongoing work is to develop software to support therapy planning and post-therapy follow-up for MRgFUS on localized prostate cancer, based on multi-parametric MR protocols. The clinical workflow of diagnosis, therapy and follow-up of MR guided FUS on prostate cancer was deeply analyzed. Based on this, the image processing workflow was designed and all necessary components, e.g. GUI, viewer, registration tools etc. were defined and implemented. The software bases on MeVisLab with several implemented C++ modules for the image processing tasks. The developed software, called LTC (Local Therapy Control) will register and visualize automatically all images (T1w, T2w, DWI etc.) and ADC or perfusion maps gained from the diagnostic MRI session. This maximum of diagnostic information helps to segment all necessary ROIs, e.g. the tumor, for therapy planning. Final therapy planning will be performed based on these segmentation data in the following MRgFUS therapy session. In addition, the developed software should help to evaluate the therapy success, by synchronization and display of pre-therapeutic, therapy and follow-up image data including the therapy plan and thermal dose information. In this ongoing project, the first stand-alone prototype was completed and will be clinically evaluated.

  4. Safe and stable noninvasive focal gene delivery to the mammalian brain following focused ultrasound.

    PubMed

    Stavarache, Mihaela A; Petersen, Nicholas; Jurgens, Eric M; Milstein, Elizabeth R; Rosenfeld, Zachary B; Ballon, Douglas J; Kaplitt, Michael G

    2018-04-27

    OBJECTIVE Surgical infusion of gene therapy vectors has provided opportunities for biological manipulation of specific brain circuits in both animal models and human patients. Transient focal opening of the blood-brain barrier (BBB) by MR-guided focused ultrasound (MRgFUS) raises the possibility of noninvasive CNS gene therapy to target precise brain regions. However, variable efficiency and short follow-up of studies to date, along with recent suggestions of the potential for immune reactions following MRgFUS BBB disruption, all raise questions regarding the viability of this approach for clinical translation. The objective of the current study was to evaluate the efficiency, safety, and long-term stability of MRgFUS-mediated noninvasive gene therapy in the mammalian brain. METHODS Focused ultrasound under the control of MRI, in combination with microbubbles consisting of albumin-coated gas microspheres, was applied to rat striatum, followed by intravenous infusion of an adeno-associated virus serotype 1/2 (AAV1/2) vector expressing green fluorescent protein (GFP) as a marker. Following recovery, animals were followed from several hours up to 15 months. Immunostaining for GFP quantified transduction efficiency and stability of expression. Quantification of neuronal markers was used to determine histological safety over time, while inflammatory markers were examined for evidence of immune responses. RESULTS Transitory disruption of the BBB by MRgFUS resulted in efficient delivery of the AAV1/2 vector to the targeted rodent striatum, with 50%-75% of striatal neurons transduced on average. GFP transgene expression appeared to be stable over extended periods of time, from 2 weeks to 6 months, with evidence of ongoing stable expression as long as 16 months in a smaller cohort of animals. No evidence of substantial toxicity, tissue injury, or neuronal loss was observed. While transient inflammation from BBB disruption alone was noted for the first few days, consistent

  5. [The use of intraoperative Doppler ultrasound in endoscopic transsphenoidal surgery].

    PubMed

    Sharipov, O I; Kutin, M A; Kalinin, P L; Fomichev, D V; Lukshin, V A; Kurnosov, A B

    2016-01-01

    Doppler ultrasound (DUS) has been widely used in neurosurgical practice to diagnose various cerebrovascular diseases. This technique is used in transsphenoidal surgery to identify the localization of intracranial arteries when making an approach or during tumor resection. To identify the cavernous segment of the internal carotid artery (ICA) and/or basilar artery during endoscopic transsphenoidal surgery, we used a combined device on the basis of a click line curette («Karl Storz») and a 16 MHz Doppler probe (Lassamed). The technique was used in 51 patients during both standard transsphenoidal surgery (23 cases) and transsphenoidal tumor resection through an extended approach (28 cases). Doppler ultrasound was used in different situations: to determine a trajectory of the endonasal transsphenoidal approach in the absence of the normal anatomical landmarks (16 cases), to define the limits of safe resection of a tumor located in the laterosellar region (7), and to implement an extended transsphenoidal endoscopic approach (28). Intraoperative Doppler ultrasound enabled identification of the cavernous segment of the internal carotid artery in 45 cases and the basilar artery in 2 cases; a blood vessel was not found in 4 cases. Injury to the cavernous segment of the internal carotid artery was observed only in 1 case. The use of the described combined device in transsphenoidal surgery turned Doppler ultrasound into an important and useful technique for visualization of the ICA within the tumor stroma as well as in the case of the changed skull base anatomy. Its use facilitates manipulations in a deep and narrow wound and enables inspection of the entire surface of the operative field in various planes, thereby surgery becomes safer due to the possibility of maximum investigation of the operative field.

  6. Intraoperative Ultrasound in Patients Undergoing Transsphenoidal Surgery for Pituitary Adenoma: Systematic Review [corrected].

    PubMed

    Marcus, Hani J; Vercauteren, Tom; Ourselin, Sebastien; Dorward, Neil L

    2017-10-01

    Transsphenoidal surgery is the gold standard for pituitary adenoma resection. However, despite advances in microsurgical and endoscopic techniques, some pituitary adenomas can be challenging to cure. We sought to determine whether, in patients undergoing transsphenoidal surgery for pituitary adenoma, intraoperative ultrasound is a safe and effective technologic adjunct. The PubMed database was searched between January 1996 and January 2016 to identify relevant publications that 1) featured patients undergoing transsphenoidal surgery for pituitary adenoma, 2) used intraoperative ultrasound, and 3) reported on safety or effectiveness. Reference lists were also checked, and expert opinions were sought to identify further publications. Ultimately, 10 studies were included, comprising 1 cohort study, 7 case series, and 2 case reports. One study reported their prototype probe malfunctioned, leading to false-positive results in 2 cases, and another study' prototype probe was too large to safely enter the sphenoid sinus in 2 cases. Otherwise, no safety issues directly related to use of intraoperative ultrasound were reported. In the only comparative study, remission occurred in 89.7% (61/68) of patients with Cushing disease in whom intraoperative ultrasound was used, compared with 83.8% (57/68) in whom it was not. All studies reported that surgeons anecdotally found intraoperative ultrasound helpful. Although there is limited and low-quality evidence available, the use of intraoperative ultrasound appears to be a safe and effective technologic adjunct to transsphenoidal surgery for pituitary adenoma. Advances in ultrasound technology may allow for more widespread use of such devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.

    PubMed

    Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu

    2015-11-01

    Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.

  8. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advancedmore » techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.« less

  9. Three-dimensional ultrasound and image-directed surgery: implications for operating room personnel.

    PubMed

    Macedonia, C

    1997-04-01

    The proliferation of new imaging technologies is having a profound impact on all surgical specialties. New means of surgical visualization are allowing more surgeries to be performed less invasively. Three-dimensional ultrasound is a technology that has potential as a diagnostic tool, as a presurgical planning simulator, and as an adjunct to image-directed surgery. This article describes how three-dimensional ultrasound is being used by the United States Department of Defense and how it may change the role of the perioperative nurse in the near future.

  10. Clinical utility of carotid duplex ultrasound prior to cardiac surgery.

    PubMed

    Lin, Judith C; Kabbani, Loay S; Peterson, Edward L; Masabni, Khalil; Morgan, Jeffrey A; Brooks, Sara; Wertella, Kathleen P; Paone, Gaetano

    2016-03-01

    Clinical utility and cost-effectiveness of carotid duplex examination prior to cardiac surgery have been questioned by the multidisciplinary committee creating the 2012 Appropriate Use Criteria for Peripheral Vascular Laboratory Testing. We report the clinical outcomes and postoperative neurologic symptoms in patients who underwent carotid duplex ultrasound prior to open heart surgery at a tertiary institution. Using the combined databases from our clinical vascular laboratory and the Society of Thoracic Surgery, a retrospective analysis of all patients who underwent carotid duplex ultrasound within 13 months prior to open heart surgery from March 2005 to March 2013 was performed. The outcomes between those who underwent carotid duplex scanning (group A) and those who did not (group B) were compared. Among 3233 patients in the cohort who underwent cardiac surgery, 515 (15.9%) patients underwent a carotid duplex ultrasound preoperatively, and 2718 patients did not (84.1%). Among the patients who underwent carotid screening vs no screening, there was no statistically significant difference in the risk factors of cerebrovascular disease (10.9% vs 12.7%; P = .26), prior stroke (8.2% vs 7.2%; P = .41), and prior transient ischemic attack (2.9% vs 3.3%; P = .24). For those undergoing isolated coronary artery bypass grafting (CABG), 306 (17.8%) of 1723 patients underwent preoperative carotid duplex ultrasound. Among patients who had carotid screening prior to CABG, the incidence of carotid disease was low: 249 (81.4%) had minimal or mild stenosis (<50%); 25 (8.2%) had unilateral moderate stenosis (50%-69%); 10 (3.3%) had bilateral moderate stenosis; 9 (2.9%) had unilateral severe stenosis (70%-99%); 5 (1.6%) had contralateral moderate stenosis; 2 (0.7%) had bilateral severe stenosis; 4 (1.3%) had unilateral occluded with contralateral less than 50% stenosis, 1 (0.3%) had unilateral occluded with contralateral (70%-99%) stenosis; and 1 had bilateral occluded carotid

  11. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial)

    PubMed Central

    2011-01-01

    Background Breast-conserving surgery for breast cancer was developed as a method to preserve healthy breast tissue, thereby improving cosmetic outcomes. Thus far, the primary aim of breast-conserving surgery has been the achievement of tumour-free resection margins and prevention of local recurrence, whereas the cosmetic outcome has been considered less important. Large studies have reported poor cosmetic outcomes in 20-40% of patients after breast-conserving surgery, with the volume of the resected breast tissue being the major determinant. There is clear evidence for the efficacy of ultrasonography in the resection of nonpalpable tumours. Surgical resection of palpable breast cancer is performed with guidance by intra-operative palpation. These palpation-guided excisions often result in an unnecessarily wide resection of adjacent healthy breast tissue, while the rate of tumour-involved resection margins is still high. It is hypothesised that the use of intra-operative ultrasonography in the excision of palpable breast cancer will improve the ability to spare healthy breast tissue while maintaining or even improving the oncological margin status. The aim of this study is to compare ultrasound-guided surgery for palpable tumours with the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumour-free margins, cosmetic outcomes and quality of life. Methods/design In this prospective multicentre randomised controlled clinical trial, 120 women who have been diagnosed with palpable early-stage (T1-2N0-1) primary invasive breast cancer and deemed suitable for breast-conserving surgery will be randomised between ultrasound-guided surgery and palpation-guided surgery. With this sample size, an expected 20% reduction of resected breast tissue and an 18% difference in tumour-free margins can be detected with a power of 80%. Secondary endpoints include cosmetic outcomes and quality of life. The rationale, study

  12. Is it time to include point-of-care ultrasound in general surgery training? A review to stimulate discussion.

    PubMed

    Mollenkopf, Maximilian; Tait, Noel

    2013-12-01

    Point-of-care ultrasound scanning or POCUS is a focused ultrasound (US) scan, performed by non-imaging clinicians during physical examination, an invasive procedure or surgery. As this technology becomes cheaper, smaller and easier to use, its scope for use by surgeons grows, a trend that may generate a gap between use and training. Opportunities for enhanced general surgery skill sets may be reduced unless consideration is given to inclusion of POCUS in general surgery training. To stimulate discussion regarding inclusion of POCUS in the general surgery curriculum; to resource this discussion with an overview of current trends and issues around POCUS; and to discuss concerns and controversies that may arise if POCUS was adopted into general surgery training. A literature search was performed using PUBMED, MEDLINE, Google and Google Scholar, using the terms 'ultrasound', 'point-of-care-ultrasound', 'bedside ultrasound', 'portable ultrasound' and 'hand-held ultrasound'. Literature, references and non-literature resources found were reviewed for relevance to US education in general surgery. Increasingly, medical students are graduating with basic POCUS skills. Specialty-specific uses of POCUS are proliferating. Training and assessment resources are not keeping up, in accessibility or standardization. A learned surgical college led training and accreditation process would require aligned education in anatomy and US technology and collaboration with the specialist imaging community to ensure appropriate standards are clarified and met. Research is also required into how general surgery trainees can best achieve and maintain POCUS competence. © 2013 Royal Australasian College of Surgeons.

  13. A study of novel bilateral thermal capsulotomy with focused ultrasound for treatment-refractory obsessive-compulsive disorder: 2-year follow-up.

    PubMed

    Kim, Se Joo; Roh, Daeyoung; Jung, Hyun Ho; Chang, Won Seok; Kim, Chan-Hyung; Chang, Jin Woo

    2018-05-02

    Recently, a new thermal lesioning approach using magnetic-resonance-guided focused ultrasound (MRgFUS) was introduced for the treatment of neurologic disorders. However, only 2 studies have used this approach for treatment-refractory obsessive-compulsive disorder (OCD), and follow-up was short-term. We investigated the efficacy and safety of bilateral thermal lesioning of the anterior limb of the internal capsule using MRgFUS in patients with treatment-refractory OCD and followed them for 2 years. Eleven patients with treatment-refractory OCD were included in the study. Clinical outcomes were evaluated using the Yale-Brown Obsessive Compulsive Scale, the Clinical Global Impression scale (including improvement and severity), the Hamilton Rating Scale for Depression (HAM-D) and the Hamilton Rating Scale for Anxiety (HAM-A) at 1 week and 1, 3, 6, 12 and 24 months following MRgFUS. Neuropsychological functioning, Global Assessment of Functioning and adverse events were also assessed. After MRgFUS, Yale-Brown Obsessive Compulsive Scale scores decreased significantly across the 24-month follow-up period (mean ± standard deviation, 34.4 ± 2.3 at baseline v. 21.3 ± 6.2 at 24 months, p < 0.001). Scores on the Hamilton rating scales for depression and anxiety also significantly decreased from baseline to 24 months (HAM-D, 19.0 ± 5.3 v. 7.6 ± 5.3, p < 0.001; HAM-A, 22.4 ± 5.9 v. 7.9 ± 3.9, p < 0.001). Global Assessment of Functioning scores improved significantly (35.8 ± 4.9 at baseline v. 56.0 ± 10.3 at 24 months, p < 0.001) and Memory Quotient significantly improved, but other neuropsychological functions were unchanged. The side effects of MRgFUS included headache and vestibular symptoms, but these were mild and transient. The main limitations of this study were the small sample size and the open-label design. Bilateral thermal lesioning of the anterior limb of the internal capsule using MRgFUS may improve obsessive-compulsive, depressive and anxiety symptoms in

  14. Diagnostic value of chest ultrasound after cardiac surgery: a comparison with chest X-ray and auscultation.

    PubMed

    Vezzani, Antonella; Manca, Tullio; Brusasco, Claudia; Santori, Gregorio; Valentino, Massimo; Nicolini, Francesco; Molardi, Alberto; Gherli, Tiziano; Corradi, Francesco

    2014-12-01

    Chest auscultation and chest x-ray commonly are used to detect postoperative abnormalities and complications in patients admitted to intensive care after cardiac surgery. The aim of the study was to evaluate whether chest ultrasound represents an effective alternative to bedside chest x-ray to identify early postoperative abnormalities. Diagnostic accuracy of chest auscultation and chest ultrasound were compared in identifying individual abnormalities detected by chest x-ray, considered the reference method. Cardiac surgery intensive care unit. One hundred fifty-one consecutive adult patients undergoing cardiac surgery. All patients included were studied by chest auscultation, ultrasound, and x-ray upon admission to intensive care after cardiac surgery. Six lung pathologic changes and endotracheal tube malposition were found. There was a highly significant correlation between abnormalities detected by chest ultrasound and x-ray (k = 0.90), but a poor correlation between chest auscultation and x-ray abnormalities (k = 0.15). Chest auscultation may help identify endotracheal tube misplacement and tension pneumothorax but it may miss most major abnormalities. Chest ultrasound represents a valid alternative to chest x-ray to detect most postoperative abnormalities and misplacements. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Implementation of real-time ultrasound in a thoracic surgery practice.

    PubMed

    Coonar, Aman S; Hughes, Jacqueline A; Walker, Susan; dePerrot, Marc; Waddell, Thomas K; Pierre, Andrew F; Darling, Gail E; Johnston, Michael R; Keshavjee, Shaf

    2009-05-01

    The purpose of this study was to implement real-time transthoracic ultrasound in a thoracic surgery and lung transplant practice. Ultrasound units that are light, small, robust, and portable are now available. Obstacles to use include demarcation issues between specialties, training, and a perception that basic ultrasound may be difficult to use. The experience of implementing this is described. After a training period, 62 studies were performed in 4 months. Patients and clinicians gave positive feedback. The learning time was short, and with ultrasonic guidance, all interventional procedures were successful at the first attempt, without any complications. Basic transthoracic ultrasound was found to be easy to learn and use by thoracic surgeons, fellows, and specialist nurses. Patients were appreciative. Real-time use may have genuine advantages to patient care.

  16. Ultrasound-guided percutaneous injection of methylene blue to identify nerve pathology and guide surgery.

    PubMed

    Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel

    2015-09-01

    OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.

  17. Improving Thermal Dose Accuracy in Magnetic Resonance-Guided Focused Ultrasound Surgery: Long-Term Thermometry Using a Prior Baseline as a Reference

    PubMed Central

    Bitton, Rachel R.; Webb, Taylor D.; Pauly, Kim Butts; Ghanouni, Pejman

    2015-01-01

    Purpose To investigate thermal dose volume (TDV) and non-perfused volume (NPV) of magnetic resonance-guided focused ultrasound (MRgFUS) treatments in patients with soft tissue tumors, and describe a method for MR thermal dosimetry using a baseline reference. Materials and Methods Agreement between TDV and immediate post treatment NPV was evaluated from MRgFUS treatments of five patients with biopsy-proven desmoid tumors. Thermometry data (gradient echo, 3T) were analyzed over the entire course of the treatments to discern temperature errors in the standard approach. The technique searches previously acquired baseline images for a match using 2D normalized cross-correlation and a weighted mean of phase difference images. Thermal dose maps and TDVs were recalculated using the matched baseline and compared to NPV. Results TDV and NPV showed between 47%–91% disagreement, using the standard immediate baseline method for calculating TDV. Long-term thermometry showed a nonlinear local temperature accrual, where peak additional temperature varied between 4–13°C (mean = 7.8°C) across patients. The prior baseline method could be implemented by finding a previously acquired matching baseline 61% ± 8% (mean ± SD) of the time. We found 7%–42% of the disagreement between TDV and NPV was due to errors in thermometry caused by heat accrual. For all patients, the prior baseline method increased the estimated treatment volume and reduced the discrepancies between TDV and NPV (P = 0.023). Conclusion This study presents a mismatch between in-treatment and post treatment efficacy measures. The prior baseline approach accounts for local heating and improves the accuracy of thermal dose-predicted volume. PMID:26119129

  18. Improving thermal dose accuracy in magnetic resonance-guided focused ultrasound surgery: Long-term thermometry using a prior baseline as a reference.

    PubMed

    Bitton, Rachel R; Webb, Taylor D; Pauly, Kim Butts; Ghanouni, Pejman

    2016-01-01

    To investigate thermal dose volume (TDV) and non-perfused volume (NPV) of magnetic resonance-guided focused ultrasound (MRgFUS) treatments in patients with soft tissue tumors, and describe a method for MR thermal dosimetry using a baseline reference. Agreement between TDV and immediate post treatment NPV was evaluated from MRgFUS treatments of five patients with biopsy-proven desmoid tumors. Thermometry data (gradient echo, 3T) were analyzed over the entire course of the treatments to discern temperature errors in the standard approach. The technique searches previously acquired baseline images for a match using 2D normalized cross-correlation and a weighted mean of phase difference images. Thermal dose maps and TDVs were recalculated using the matched baseline and compared to NPV. TDV and NPV showed between 47%-91% disagreement, using the standard immediate baseline method for calculating TDV. Long-term thermometry showed a nonlinear local temperature accrual, where peak additional temperature varied between 4-13°C (mean = 7.8°C) across patients. The prior baseline method could be implemented by finding a previously acquired matching baseline 61% ± 8% (mean ± SD) of the time. We found 7%-42% of the disagreement between TDV and NPV was due to errors in thermometry caused by heat accrual. For all patients, the prior baseline method increased the estimated treatment volume and reduced the discrepancies between TDV and NPV (P = 0.023). This study presents a mismatch between in-treatment and post treatment efficacy measures. The prior baseline approach accounts for local heating and improves the accuracy of thermal dose-predicted volume. © 2015 Wiley Periodicals, Inc.

  19. Ultrasound-Guided Rectus Sheath Block in Gynaecological Surgery with Pfannenstiel Incision

    PubMed Central

    Cüneyitoğlu, Şule; Türktan, Mediha; Biricik, Ebru; Özcengiz, Dilek

    2015-01-01

    Objective This study aimed to evaluate the effects of ultrasound-guided rectus sheath block in gynaecological surgery with Pfannenstiel incision. Methods After the approval of the ethics committee and the patients’ consent, 75 ASA I–II patients who were aged between 20 and 70 years and scheduled for a gynaecological surgery with Pfannenstiel incision were included in this study. After induction of general anaesthesia, patients were randomly divided into three groups. In Group UR patients (n=25), ultrasound-guided rectus sheath block with 0.25% levobupivacaine (0.2 mL kg−1) was performed. In Group SR patients (n=25), surgical rectus sheath block with 0.25% levobupivacaine (0.2 mL kg−1) was applied. In Group T (n=25) patients, tramadol (2 mg kg−1) was intravenously administered 30 min before the end of surgery. Patient-controlled analgesia device was established for postoperative pain relief in all groups. Haemodynamic data and inspired sevoflurane concentration were recorded during the operation. Pain scores, total tramadol consumption, supplemental analgesic requirement and side effects were postoperatively evaluated. Results Demographic characteristics, duration of surgery and haemodynamic parameters were similar between the groups. Inspired sevoflurane concentration (%) and VAS scores were significantly lower in Group UR than those in Groups SR and T. Total tramadol consumption was significantly lower in Groups UR and SR than that in Group T. There was no significant difference in the incidence of side effects. Conclusion This study demonstrates that ultrasound-guided rectus sheath block helps to provide the effective analgesia without any side effects compared with surgical rectus sheath block and intravenous tramadol for gynaecological surgery with Pfannenstiel incision. PMID:27366521

  20. Ultrasound-Guided Rectus Sheath Block in Gynaecological Surgery with Pfannenstiel Incision.

    PubMed

    Cüneyitoğlu, Şule; Türktan, Mediha; Biricik, Ebru; Özcengiz, Dilek

    2015-10-01

    This study aimed to evaluate the effects of ultrasound-guided rectus sheath block in gynaecological surgery with Pfannenstiel incision. After the approval of the ethics committee and the patients' consent, 75 ASA I-II patients who were aged between 20 and 70 years and scheduled for a gynaecological surgery with Pfannenstiel incision were included in this study. After induction of general anaesthesia, patients were randomly divided into three groups. In Group UR patients (n=25), ultrasound-guided rectus sheath block with 0.25% levobupivacaine (0.2 mL kg(-1)) was performed. In Group SR patients (n=25), surgical rectus sheath block with 0.25% levobupivacaine (0.2 mL kg(-1)) was applied. In Group T (n=25) patients, tramadol (2 mg kg(-1)) was intravenously administered 30 min before the end of surgery. Patient-controlled analgesia device was established for postoperative pain relief in all groups. Haemodynamic data and inspired sevoflurane concentration were recorded during the operation. Pain scores, total tramadol consumption, supplemental analgesic requirement and side effects were postoperatively evaluated. Demographic characteristics, duration of surgery and haemodynamic parameters were similar between the groups. Inspired sevoflurane concentration (%) and VAS scores were significantly lower in Group UR than those in Groups SR and T. Total tramadol consumption was significantly lower in Groups UR and SR than that in Group T. There was no significant difference in the incidence of side effects. This study demonstrates that ultrasound-guided rectus sheath block helps to provide the effective analgesia without any side effects compared with surgical rectus sheath block and intravenous tramadol for gynaecological surgery with Pfannenstiel incision.

  1. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    PubMed

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  2. Focused Ultrasound Surgery in Oncology: Overview and Principles

    PubMed Central

    McDannold, Nathan J.; Hynynen, Kullervo; Jolesz, Ferenc A.

    2011-01-01

    Focused ultrasound surgery (FUS) is a noninvasive image-guided therapy and an alternative to surgical interventions. It presents an opportunity to revolutionize cancer therapy and to affect or change drug delivery of therapeutic agents in new focally targeted ways. In this article the background, principles, technical devices, and clinical cancer applications of image-guided FUS are reviewed. © RSNA, 2011 PMID:21436096

  3. A novel ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  4. Intra-operative feedback and dynamic compensation for image-guided robotic focal ultrasound surgery.

    PubMed

    Chauhan, S; Amir, H; Chen, G; Hacker, A; Michel, M S; Koehrmann, K U

    2008-11-01

    This paper describes a non-invasive remote temperature measurement technique integrated with a biomechatronic surgery system devised in our laboratory and named FUSBOT (Focal Ultrasound Surgery RoBOT). FUSBOTs use High-Intensity Focused Ultrasound (HIFU) for ablation of cancers/tumors and targets accessible through various soft-tissue acoustic windows in the human body. The focused ultrasound beam parameters are chosen so that biologically significant temperature rises are achieved only within the focal volume. In this paper, FUSBOT(BS), a customized system for breast surgery, is taken as a representative example to demonstrate the implementation and the results of non-invasive feedback during ablation. An 8-axis PC-based controller controls various sub-sections of the system within a safe constrained work envelope. Temperature is a prime target parameter in ablative procedures, and it is of paramount importance that means should be devised for its measurement and control in order to design optimal dose protocols and judge the efficacy of FUS systems. A customized sensory interface is devised and integrated with FUSBOT(BS), and dedicated software algorithms are embedded for surgical planning based on real-time guidance and feedback. Variations in the physical parameters of the tissue interacting with the incident modality are used as surgical feedback. The use of real-time ultrasound imaging and data processed from various sensors to deduce lesion position and thermal feedback during surgery, as integrated with the robotic system for online surgical planning, is described. Dynamic registration algorithms are developed for compensation and re-registration of the robotic end-effector with respect to the target, and representative empirical outcomes for lesion tracking and online temperature estimation in various biological tissues are presented.

  5. Sphincter lesions observed on ultrasound after transanal endoscopic surgery.

    PubMed

    Mora López, Laura; Serra-Aracil, Xavier; Navarro Soto, Salvador

    2015-12-14

    To assess the morphological impact of transanal endoscopic surgery on the sphincter apparatus using the modified Starck classification. A prospective, observational study of 118 consecutive patients undergoing Transanal Endoscopic Operation/Transanal Endoscopic Microsurgery (TEO/TEM) from March 2013 to May 2014 was performed. All the patients underwent an endoanal ultrasound prior to surgery and one and four months postoperatively in order to measure sphincter width, identify sphincter defects and to quantify them in terms of the level, depth and size of the affected anal canal. To assess the lesions, we used the "modified" Starck classification, which incorporates the variable "sphincter fragmentation". The results were correlated with the Wexner incontinence questionnaire. Of the 118 patients, twelve (sphincter lesions) were excluded. The results of the 106 patients were as follows after one month: 31 (29.2%) lesions found on ultrasound after one month, median overall Starck score of 4 (range 3-6); 10 (9.4%) defects in the internal anal sphincter (IAS) and 3 (2.8%) in the external anal sphincter (EAS); 17 patients (16%) had fragmentation of the sphincter apparatus with both sphincters affected in one case. At four months: 7 (6.6%) defects, all in the IAS, overall median Starck score of 4 (range 3-6). Mean IAS widths were 3.5 mm (SD 1.14) preoperatively, 4.38 mm (SD 2.1) one month postoperatively and 4.03 mm (SD 1.46) four months postoperatively. The only statistically significant difference in sphincter width in the IAS measurements was between preoperatively and one month postoperatively. No incontinence was reported, even in cases of ultrasound abnormalities. TEO/TEM may produce ultrasound abnormalities but this is not accompanied by clinical changes in continence. The modified Starck classification is useful for describing and managing these disorders.

  6. High-intensity focused ultrasound in obstetrics and gynecology: the birth of a new era of noninvasive surgery?

    PubMed

    Griffiths, A; terHaar, G; Rivens, I; Giussani, D; Lees, C

    2012-12-01

    Although ultrasound is an essential investigative modality in obstetrics and gynecology, the potential for therapeutic high-intensity focused ultrasound (HIFU) (also referred to as focused ultrasound surgery, FUS) to offer an alternative to invasive surgery is less well known. The ability of HIFU to create discrete regions of tissue necrosis only in precisely targeted positions by careful placement of the focus, without the need for any surgical intervention, has made HIFU of interest to those seeking noninvasive alternatives to conventional abdominal surgery. This article reviews the current experimental and clinical experience with HIFU in obstetrics and gynecology, and outlines potential future applications in fetal medicine and the challenges faced in their development. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Comparison possibilities of ultrasound and its combination with laser in surgery and therapy

    NASA Astrophysics Data System (ADS)

    Zharov, Vladimir P.; Menyaev, Yulian A.; Kabisov, Ruslan K.; Alkov, Sergey V.; Nesterov, A. V.; Loshchilov, Vladimir I.; Suen, James Y.

    2000-05-01

    This article presents the further developments of combined laser-ultrasound medical technologies with paying attention the possibility ultrasound in surgery and therapy. The analyses of main effects at the low frequency ultrasonic treatment of biotissues including cavitation, acoustic streams, acoustic pressure, mechanical influence etc are analyzed. The main promising areas of application of low frequency ultrasound are considered including bactericidal treatment of infections wounds, spray treatment of wounds in head and neck surgery, tumor treatment etc. In particular the clinical result of using ultrasonic devices based on imposing ultrasonic oscillations in a range of 22-66 kHz on a cutting instrument with a special form, radiation intensity up to 10 W/cm2 and oscillation amplitude up to 40-60 micrometers with respect to oncology for halt bleeding from a tumor, liquidating pain, acoustic denervation are presented. Some limitation of medical application of ultrasound are discussed and perspective combination with laser for increasing efficiency of new combined technologies are found. Among them: combination photodynamic therapy and ultrasonic treatment of tumors, laser-ultrasonic treatment of infections wounds including using spray, laser-ultrasonic drug delivery. The preliminary result of experimental study of some of above-mentioned technologies are presented.

  8. Restoring Neurological Physiology: The Innovative Role of High-Energy MR-Guided Focused Ultrasound (HIMRgFUS). Preliminary Data from a New Method of Lesioning Surgery.

    PubMed

    Giugno, Antonella; Maugeri, Rosario; Graziano, Francesca; Gagliardo, Cesare; Franzini, Angelo; Catalano, Carlo; Midiri, Massimo; Iacopino, Domenico Gerardo

    2017-01-01

    Tremor is a disabling condition, common to several neurodegenerative diseases. Lesioning procedures and deep brain stimulation, respectively, of the ventralis intermedius nucleus for intentional tremor, and of the subthalamic nucleus for parkinsonian resting tremor, have been introduced in clinical practice for patients refractory to medical treatment. The combination of high-energy focused ultrasound (HIFUS) with sophisticated magnetic resonance (MR) instrumentation, together with accurate knowledge of the stereotactic brain coordinates, represents a revolution in neuromodulation. At the Neurosurgical Clinic and the Radiology Department of the University of Palermo,, two patients affected by severe and refractory forms of intentional tremor were treated by MRI-guided FUS (MRgFUS) with a unique 1.5 T MR scanner prototype that uses FUS. This apparatus is the only one of its type in the world." This is the first Italian experience, and the second in Europe, of treatment with MRI-gFUS for intentional tremor. But this is the very first experience in which a 1.5 T MRI apparatus was used. In both patients, the treatment completely abolished the tremor on the treated side, with results being excellent and stable after 7 and 5 months, respectively; no side effects were encountered. MRgFUS, recently introduced in clinical practice, and widely used at several clinical centers, has been shown to be a valid therapeutic alternative in the treatment of tremor in several neurodegenerative diseases. It is virtually safe, noninvasive, and very efficacious. We report this technique in which a 1.5 T MR scanner was used. Further investigations with long-term follow up and larger clinical series are needed.

  9. Third-molar extraction with ultrasound bone surgery: a case-control study.

    PubMed

    Mozzati, Marco; Gallesio, Giorgia; Russo, Andrea; Staiti, Giorgio; Mortellaro, Carmen

    2014-05-01

    The aim of this case-control study was to evaluate the postoperative period and healing between 2 surgical methods (traditional and ultrasound bone surgery) that are used for mandibular third-molar extraction. Fifteen patients with impaction of both of the lower third molars and indications for their extractions were used in this study. Bilateral-mandibular third-molar extractions were performed at the same surgical time: traditional surgery with burrs was used on 1 side (control site), and ultrasound surgery was used on the other side (test [T] site). After surgery, the patients were examined at 7 and 14 days and at 1 and 3 months to evaluate tissue healing. The following was assessed at every follow-up: pain, trismus, swelling, and alveolar bone level. The study included 15 patients, and 30 mandibular third-molar extractions were performed. We found only 1 postoperative complication: 1 patient had alveolitis in the control site. Complete recoveries without any complications were reported in all of the patients at the T sites. Complete recoveries without any complication were reported in all patients at the T sites. The only disadvantage of the piezoelectric technique was the length of operation time, which was increased by approximately 8 minutes; however, this effect was offset by reducing the morbidity. Our preliminary study showed that Piezosurgery is an excellent tool for reducing the risk of complications and improving the postoperative period.

  10. Stereoscopic augmented reality using ultrasound volume rendering for laparoscopic surgery in children

    NASA Astrophysics Data System (ADS)

    Oh, Jihun; Kang, Xin; Wilson, Emmanuel; Peters, Craig A.; Kane, Timothy D.; Shekhar, Raj

    2014-03-01

    In laparoscopic surgery, live video provides visualization of the exposed organ surfaces in the surgical field, but is unable to show internal structures beneath those surfaces. The laparoscopic ultrasound is often used to visualize the internal structures, but its use is limited to intermittent confirmation because of the need for an extra hand to maneuver the ultrasound probe. Other limitations of using ultrasound are the difficulty of interpretation and the need for an extra port. The size of the ultrasound transducer may also be too large for its usage in small children. In this paper, we report on an augmented reality (AR) visualization system that features continuous hands-free volumetric ultrasound scanning of the surgical anatomy and video imaging from a stereoscopic laparoscope. The acquisition of volumetric ultrasound image is realized by precisely controlling a back-and-forth movement of an ultrasound transducer mounted on a linear slider. Furthermore, the ultrasound volume is refreshed several times per minute. This scanner will sit outside of the body in the envisioned use scenario and could be even integrated into the operating table. An overlay of the maximum intensity projection (MIP) of ultrasound volume on the laparoscopic stereo video through geometric transformations features an AR visualization system particularly suitable for children, because ultrasound is radiation-free and provides higher-quality images in small patients. The proposed AR representation promises to be better than the AR representation using ultrasound slice data.

  11. Lung ultrasound compared with chest X-ray in diagnosing postoperative pulmonary complications following cardiothoracic surgery: a prospective observational study.

    PubMed

    Touw, H R; Parlevliet, K L; Beerepoot, M; Schober, P; Vonk, A; Twisk, J W; Elbers, P W; Boer, C; Tuinman, P R

    2018-03-12

    Postoperative pulmonary complications are common after cardiothoracic surgery and are associated with adverse outcomes. The ability to detect postoperative pulmonary complications using chest X-rays is limited, and this technique requires radiation exposure. Little is known about the diagnostic accuracy of lung ultrasound for the detection of postoperative pulmonary complications after cardiothoracic surgery, and we therefore aimed to compare lung ultrasound with chest X-ray to detect postoperative pulmonary complications in this group of patients. We performed this prospective, observational, single-centre study in a tertiary intensive care unit treating adult patients who had undergone cardiothoracic surgery. We recorded chest X-ray findings upon admission and on postoperative days 2 and 3, as well as rates of postoperative pulmonary complications and clinically-relevant postoperative pulmonary complications that required therapy according to the treating physician as part of their standard clinical practice. Lung ultrasound was performed by an independent researcher at the time of chest X-ray. We compared lung ultrasound with chest X-ray for the detection of postoperative pulmonary complications and clinically-relevant postoperative pulmonary complications. We also assessed inter-observer agreement for lung ultrasound, and the time to perform both imaging techniques. Subgroup analyses were performed to compare the time to detection of clinically-relevant postoperative pulmonary complications by both modalities. We recruited a total of 177 patients in whom both lung ultrasound and chest X-ray imaging were performed. Lung ultrasound identified 159 (90%) postoperative pulmonary complications on the day of admission compared with 107 (61%) identified with chest X-ray (p < 0.001). Lung ultrasound identified 11 out of 17 patients (65%) and chest X-ray 7 out of 17 patients (41%) with clinically-relevant postoperative pulmonary complications (p < 0.001). The

  12. Laser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery.

    PubMed

    Day, Alexander C; Gore, Daniel M; Bunce, Catey; Evans, Jennifer R

    2016-07-08

    Cataract is the leading cause of blindness in the world, and cataract surgery is one of the most commonly performed operations in the Western world. Preferred surgical techniques have changed dramatically over the past half century with associated improvements in outcomes and safety. Femtosecond laser platforms that can accurately and reproducibly perform key steps in cataract surgery, including corneal incisions, capsulotomy and lens fragmentation, are now available. The potential advantages of laser-assisted surgery are broad, and include greater safety and better visual outcomes through greater precision and reproducibility. To compare the effectiveness of laser-assisted cataract surgery with standard ultrasound phacoemulsification cataract surgery by gathering evidence on safety from randomised controlled trials (RCTs). We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 4), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to May 2016), EMBASE (January 1980 to May 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to May 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the U.S. Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 May 2016. We included randomised controlled trials where laser-assisted cataract surgery was compared to standard ultrasound phacoemulsification cataract surgery. We graded the certainty of the evidence using GRADE. Two review authors independently screened the search results, assessed risk of bias and extracted data using the standard methodological

  13. High-intensity focused ultrasound: advances in technology and experimental trials support enhanced utility of focused ultrasound surgery in oncology

    PubMed Central

    Malietzis, G; Monzon, L; Hand, J; Wasan, H; Leen, E; Abel, M; Muhammad, A; Abel, P

    2013-01-01

    High-intensity focused ultrasound (HIFU) is a rapidly maturing technology with diverse clinical applications. In the field of oncology, the use of HIFU to non-invasively cause tissue necrosis in a defined target, a technique known as focused ultrasound surgery (FUS), has considerable potential for tumour ablation. In this article, we outline the development and underlying principles of HIFU, overview the limitations and commercially available equipment for FUS, then summarise some of the recent technological advances and experimental clinical trials that we predict will have a positive impact on extending the role of FUS in cancer therapy. PMID:23403455

  14. Physiological Motion and Registration of Abnormalities in Liver During Focused Ultrasound Surgery

    NASA Astrophysics Data System (ADS)

    Chauhan, Sunita; Rh, Abhilash

    Continuous deformation and dislocation of soft tissues in the abdominal and thoracic region presents a major issue for effective targeting of all non-invasive ablative modalities such as radiotherapy/surgery and Focused Ultrasound Surgery. Most significant among these is the movement of the target organs due to physiological processes such as respiration. The movement is found to be most significant for liver and kidneys. We studied movement and compensation strategies with the aim to implement them during ultrasound ablation using our robotic system for targeted FUS dose delivery. The motion pattern of the liver can be assumed to be in a single plane as it closely follows the movement of the diaphragm. However, the movement of kidneys is three dimensional and follows complicated patterns. Kidney motion is highly subject specific and has poor repeatability. In our research, we quantify the relation of liver movement and the breathing pattern so as to achieve real-time movement compensation using a prediction-correlation approach.

  15. Preoperative magnetic resonance and intraoperative ultrasound fusion imaging for real-time neuronavigation in brain tumor surgery.

    PubMed

    Prada, F; Del Bene, M; Mattei, L; Lodigiani, L; DeBeni, S; Kolev, V; Vetrano, I; Solbiati, L; Sakas, G; DiMeco, F

    2015-04-01

    Brain shift and tissue deformation during surgery for intracranial lesions are the main actual limitations of neuro-navigation (NN), which currently relies mainly on preoperative imaging. Ultrasound (US), being a real-time imaging modality, is becoming progressively more widespread during neurosurgical procedures, but most neurosurgeons, trained on axial computed tomography (CT) and magnetic resonance imaging (MRI) slices, lack specific US training and have difficulties recognizing anatomic structures with the same confidence as in preoperative imaging. Therefore real-time intraoperative fusion imaging (FI) between preoperative imaging and intraoperative ultrasound (ioUS) for virtual navigation (VN) is highly desirable. We describe our procedure for real-time navigation during surgery for different cerebral lesions. We performed fusion imaging with virtual navigation for patients undergoing surgery for brain lesion removal using an ultrasound-based real-time neuro-navigation system that fuses intraoperative cerebral ultrasound with preoperative MRI and simultaneously displays an MRI slice coplanar to an ioUS image. 58 patients underwent surgery at our institution for intracranial lesion removal with image guidance using a US system equipped with fusion imaging for neuro-navigation. In all cases the initial (external) registration error obtained by the corresponding anatomical landmark procedure was below 2 mm and the craniotomy was correctly placed. The transdural window gave satisfactory US image quality and the lesion was always detectable and measurable on both axes. Brain shift/deformation correction has been successfully employed in 42 cases to restore the co-registration during surgery. The accuracy of ioUS/MRI fusion/overlapping was confirmed intraoperatively under direct visualization of anatomic landmarks and the error was < 3 mm in all cases (100 %). Neuro-navigation using intraoperative US integrated with preoperative MRI is reliable, accurate

  16. Optimizing sonication protocols for transthoracic focused ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Gao, J.; Volovick, A.; Cao, R.; Nabi, G.; Cochran, S.; Melzer, A.; Huang, Z.

    2012-11-01

    During transthoracic focused ultrasound surgery (TFUS), the intervening ribs absorb and reflect the majority of the ultrasound energy excited by an acoustic source, resulting in pain, bone injuries and insufficient energy delivered to the target organs of liver, kidney, and pancreas. Localized hot spots may also exist at the interfaces between the ribs and soft tissue and in the highly absorptive regions such as the skin and connective tissue. The aims of this study were to clarify the effects of focal beam distortion and frequency-dependent rib heating in TFUS and to propose possible techniques to reduce the side-effects of rib heating and increase ultrasound efficacy. Frequency-dependent heating at the target and the ribs were estimated using finite element analysis (PZFlex, Weidlinger Associates Inc, USA) along with experimental verification on a range of different phantoms. The ratio of ultrasonic power density at the target and the ribs, the time-varying spatial distribution of temperature, and the ablated focus of each sonication were taken as key indicators to determine the optimal operating frequency. Comparison with a patient specific model was also made. TFUS seems to be useful to treat tumours that are small and near the surface of the abdominal organs. For targets deep inside these organs, severe attenuation of energy occurs, suggesting that purely ultrasound thermal ablation with advanced heating patterns will have limited effects in improving the treatment efficacy. Results demonstrate that the optimal ultrasound frequency is around 0.8 MHz for the configurations considered, but this may shift to higher frequencies with changes in the axial and lateral positions of the tumours relative to the ribs. To date, we have elucidated the most important effects and correlated these with idealised anatomical geometry. The changes in frequency and other techniques such as selection of excited element patterns in FUS arrays had some effect. However, more advanced

  17. National variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic carotid artery stenosis.

    PubMed

    Arous, Edward J; Simons, Jessica P; Flahive, Julie M; Beck, Adam W; Stone, David H; Hoel, Andrew W; Messina, Louis M; Schanzer, Andres

    2015-10-01

    Carotid endarterectomy (CEA) for asymptomatic carotid artery stenosis is among the most common procedures performed in the United States. However, consensus is lacking regarding optimal preoperative imaging, carotid duplex ultrasound criteria, and ultimately, the threshold for surgery. We sought to characterize national variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic CEA. The Society for Vascular Surgery Vascular Quality Initiative (VQI) database was used to identify all CEA procedures performed for asymptomatic carotid artery stenosis between 2003 and 2014. VQI currently captures 100% of CEA procedures performed at >300 centers by >2000 physicians nationwide. Three analyses were performed to quantify the variation in (1) preoperative imaging, (2) carotid duplex ultrasound criteria, and (3) threshold for surgery. Of 35,695 CEA procedures in 33,488 patients, the study cohort was limited to 19,610 CEA procedures (55%) performed for asymptomatic disease. The preoperative imaging modality used before CEA varied widely, with 57% of patients receiving a single preoperative imaging study (duplex ultrasound imaging, 46%; computed tomography angiography, 7.5%; magnetic resonance angiography, 2.0%; cerebral angiography, 1.3%) and 43% of patients receiving multiple preoperative imaging studies. Of the 16,452 asymptomatic patients (89%) who underwent preoperative duplex ultrasound imaging, there was significant variability between centers in the degree of stenosis (50%-69%, 70%-79%, 80%-99%) designated for a given peak systolic velocity, end diastolic velocity, and internal carotid artery-to-common carotid artery ratio. Although 68% of CEA procedures in asymptomatic patients were performed for an 80% to 99% stenosis, 26% were performed for a 70% to 79% stenosis, and 4.1% were performed for a 50% to 69% stenosis. At the surgeon level, the range in the percentage of CEA procedures performed for a <80% asymptomatic

  18. Quantitative Magnetic Resonance Thermometry and Its Use with MR-Guided Focused Ultrasound

    NASA Astrophysics Data System (ADS)

    Pauly, Kim

    2014-03-01

    Focused ultrasound (FUS) uses a large area array, typically outside the body, that is geometrically or electronically focused to a point deep in the body. Such focusing provides amplification of the ultrasound intensity, thereby allowing heating of tissue to the point of coagulation at the focus, without damage to the intervening tissue. Guidance of FUS treatments deep in the body can be done quantitatively with magnetic resonance (MR) thermometry, termed MRgFUS. The physics behind MR thermometry lie in the changes in hydrogen bonding with temperature. As tissue temperature rises, hydrogen bonds break, allowing the return of the electron cloud to shield water protons, reducing the magnetic field seen by the protons, and the resonant frequency. The change in resonant frequency is -0.01 ppm per degree C and is the same for all aqueous tissues. The result of the shift in proton resonant frequency is seen in the phase of gradient echo images. Subtraction of the phase of images acquired before and during heating allows the removal of background phase from other sources, yielding quantitative temperature maps. Temperature standard deviations less than 1 degree C are readily achievable and thermal dose maps are easily calculated. Thermal dose is found from a conversion of the whole temperature-time curve to an equivalent number of minutes at 43 degrees C. A thermal dose of 240 minutes is often taken as the threshold for tissue damage. MR thermometry is complicated by the motion of the target tissue and/or motion of other organs such as occurs during respiration. More sophisticated algorithms than the simple baseline subtraction take advantage of the facts that motion can be repetitive (in the case of respiratory motion) and/or the fact that the focal region in MRgFUS is small, allowing for extraction of the heat from the phase profile without subtraction of a background phase.

  19. Ultrasound-guided minimally invasive surgery for achilles tendon rupture: preliminary results.

    PubMed

    Wang, Chen-Chie; Chen, Pei-Yu; Wang, Ting-Ming; Wang, Chung-Li

    2012-07-01

    Many surgeons prefer surgical repair for Achilles tendon ruptures in an attempt to reduce the risk of rerupture. To minimize wound complications, the use of minimally invasive surgery has become more popular recently. In line with this, the use of ultrasound to guide Achilles tendon repair is reported in this study. From March 2005 to January 2008, 23 patients with Achilles tendon rupture were repaired by the same surgeon. The ages of the patients ranged from 19 to 67 years old, with an average of 43 years old. The repair of the Achilles tendon was achieved through a stab wound under the guidance of ultrasonography. A control group consisted of 25 patients who received traditional open Achilles tendon repair. The average operation time was 52 minutes, and the average wound size was 1.1 cm. The short leg cast was removed 4 weeks after the surgery, and serial casting was used for another 3 to 4 weeks. The postoperative AOFAS ankle-hindfoot scores were 98.7 in the experimental group, 96.5 in the control group with no significant difference. The rates of local infection, stiffness of the ankle, pain of the scar and sural nerve injury were better in the experimental group than in the control group with significant difference. Ultrasound-guided surgery was a good choice due to its availability and real-time soft tissue visualization. It can further minimize the size of the surgical wound. Our method has the potential to achieve reliable results.

  20. [Ultrasound semiotics in recurrent ovarian cancer after optimal cytoreductive surgery].

    PubMed

    Baklanova, N S; Kolomiets, L A; Frolova, I G; Viatkina, N V; Krasil'nikov, S É

    2014-01-01

    Features of ultrasound picture of morphologically verified recurrence of ovarian cancer in 21 patients are presented, who received combined treatment including cytoreductive surgery in the form of hysterectomy with oophorectomy, resection of the greater omentum and 6 courses of chemotherapy CAP for ovarian cancer stage III (FIGO). In all patients cytoreductive surgery was optimal--without residual tumor. Recurrence of the disease was detected in 12-48 months in 80.9% of the cases. Three variants of recurrence was revealed by ultrasonography: isolated peritoneal dissemination, in 14.2% of the cases, which was mainly detected during the first 12 months; single entities in the projection of the small pelvis (61.9%) and mixed form (local lesions of small pelvis and peritoneal dissemination) in 23.8% of the cases.

  1. From Grey Scale B-Mode to Elastosonography: Multimodal Ultrasound Imaging in Meningioma Surgery-Pictorial Essay and Literature Review.

    PubMed

    Prada, Francesco; Del Bene, Massimiliano; Moiraghi, Alessandro; Casali, Cecilia; Legnani, Federico Giuseppe; Saladino, Andrea; Perin, Alessandro; Vetrano, Ignazio Gaspare; Mattei, Luca; Richetta, Carla; Saini, Marco; DiMeco, Francesco

    2015-01-01

    The main goal in meningioma surgery is to achieve complete tumor removal, when possible, while improving or preserving patient neurological functions. Intraoperative imaging guidance is one fundamental tool for such achievement. In this regard, intra-operative ultrasound (ioUS) is a reliable solution to obtain real-time information during surgery and it has been applied in many different aspect of neurosurgery. In the last years, different ioUS modalities have been described: B-mode, Fusion Imaging with pre-operative acquired MRI, Doppler, contrast enhanced ultrasound (CEUS), and elastosonography. In this paper, we present our US based multimodal approach in meningioma surgery. We describe all the most relevant ioUS modalities and their intraoperative application to obtain precise and specific information regarding the lesion for a tailored approach in meningioma surgery. For each modality, we perform a review of the literature accompanied by a pictorial essay based on our routinely use of ioUS for meningioma resection.

  2. Adaptive model-predictive controller for magnetic resonance guided focused ultrasound therapy.

    PubMed

    de Bever, Joshua; Todd, Nick; Payne, Allison; Christensen, Douglas A; Roemer, Robert B

    2014-11-01

    Minimising treatment time and protecting healthy tissues are conflicting goals that play major roles in making magnetic resonance image-guided focused ultrasound (MRgFUS) therapies clinically practical. We have developed and tested in vivo an adaptive model-predictive controller (AMPC) that reduces treatment time, ensures safety and efficacy, and provides flexibility in treatment set-up. The controller realises time savings by modelling the heated treatment cell's future temperatures and thermal dose accumulation in order to anticipate the optimal time to switch to the next cell. Selected tissues are safeguarded by a configurable temperature constraint. Simulations quantified the time savings realised by each controller feature as well as the trade-offs between competing safety and treatment time parameters. In vivo experiments in rabbit thighs established the controller's effectiveness and reliability. In all in vivo experiments the target thermal dose of at least 240 CEM43 was delivered everywhere in the treatment volume. The controller's temperature safety limit reliably activated and constrained all protected tissues to <9 CEM43. Simulations demonstrated the path independence of the controller, and that a path which successively proceeds to the hottest untreated neighbouring cell leads to significant time savings, e.g. when compared to a concentric spiral path. Use of the AMPC produced a compounding time-saving effect; reducing the treatment cells' heating times concurrently reduced heating of normal tissues, which eliminated cooling periods. Adaptive model-predictive control can automatically deliver safe, effective MRgFUS treatments while significantly reducing treatment times.

  3. Robotically assisted velocity-sensitive triggered focused ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Maier, Florian; Brunner, Alexander; Jenne, Jürgen W.; Krafft, Axel J.; Semmler, Wolfhard; Bock, Michael

    2012-11-01

    Magnetic Resonance (MR) guided Focused Ultrasound Surgery (FUS) of abdominal organs is challenging due to breathing motion and limited patient access in the MR environment. In this work, an experimental robotically assisted FUS setup was combined with a MR-based navigator technique to realize motion-compensated sonications and online temperature imaging. Experiments were carried out in a static phantom, during periodic manual motion of the phantom without triggering, and with triggering to evaluate the triggering method. In contrast to the non-triggered sonication, the results of the triggered sonication show a confined symmetric temperature distribution. In conclusion, the velocity sensitive navigator can be employed for triggered FUS to compensate for periodic motion. Combined with the robotic FUS setup, flexible treatment of abdominal targets might be realized.

  4. Application of MR-guided focused pulsed ultrasound for destroying clots in vitro using thrombolytic drugs

    NASA Astrophysics Data System (ADS)

    Hadjisavvas, V.; Ioannides, K.; Damianou, C.

    2011-09-01

    In this paper an MR-guided focused pulsed ultrasound system for the treatment of stroke using thrombolytic drugs in a model in vitro is presented. A single element spherically focused transducer of 5 cm diameter; focusing at 10 cm and operating at 0.5 MHz or 1 MHz was used. The transducer was mounted in an MR compatible robot. The artery was modelled using a silicone tube. Tissue was modelled using polyaclylimide gel. Coagulated blood was used to model thrombus. A thermocouple was placed in the thrombus in order to measure the thrombus temperature. The effect of power, beam, and frequency was investigated. The goal was to maintain a temperature increase of less than 1 °C during the application of pulse ultrasound (called safe temperature). With the application of ultrasound alone there was no notable destruction of the thrombus. With the combination of ultrasound and thrombolytic drugs destruction occurred after 60 mins of pulse exposure (PRF = 1 s, duty factor = 10%, and with thrombus placed at 1 cm deep in the tissue). This simple in vitro model was proven very successful for evaluating MRgFUS as a modality for treating stroke. In the future we plan to apply this treatment protocol in live animals and humans.

  5. Pilot study of intraoperative ultrasound-guided instrument placement in nerve transection surgery for peripheral nerve pain syndromes.

    PubMed

    Henning, P Troy; Wilson, Thomas J; Willsey, Matthew; John, Jessin K; Popadich, Miriana; Yang, Lynda J S

    2017-03-01

    Surgical transection of sensory nerves in the treatment of intractable neuropathic pain is a commonly performed procedure. At times these cases can be particularly challenging when encountering obese patients, when targeting deeper nerves or those with a variable branching pattern, or in the case of repeat operations. In this case series, the authors describe their experience with ultrasound-guided surgical instrument placement during transection of a saphenous nerve in the region of prior vascular surgery in 1 patient and in the lateral femoral cutaneous nerve in 2 obese patients. The authors also describe this novel technique and provide pilot data that suggests ultrasound-assisted surgery may allow for complex cases to be completed in an expedited fashion through smaller incisions.

  6. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  7. Focal point determination in magnetic resonance-guided focused ultrasound using tracking coils.

    PubMed

    Svedin, Bryant T; Beck, Michael J; Hadley, J Rock; Merrill, Robb; de Bever, Joshua T; Bolster, Bradley D; Payne, Allison; Parker, Dennis L

    2017-06-01

    To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating. Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity. In a calibration step, low-level heating located the US focus in one transducer position orientation where the tracker positions were also known. Subsequent US focus locations were determined from the isometric transformation of the trackers. The accuracy of this method was verified by comparing the tracking coil predictions to thermal center of mass calculated using MR thermometry data acquired at 16 different transducer positions for MRgFUS sonications in a homogeneous gelatin phantom. The tracker coil predicted focus was an average distance of 2.1 ± 1.1 mm from the thermal center of mass. The one-dimensional locator sequence and prediction calculations took less than 1 s to perform. This technique accurately predicts the geometric focus for a transducer with arbitrary position and orientation without sonicating. Magn Reson Med 77:2424-2430, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Localized Harmonic Motion Imaging for Focused Ultrasound Surgery Targeting

    PubMed Central

    Curiel, Laura; Hynynen, Kullervo

    2011-01-01

    Recently, an in vivo real-time ultrasound-based monitoring technique that uses localized harmonic motion (LHM) to detect changes in tissues during focused ultrasound surgery (FUS) has been proposed to control the exposure. This technique can potentially be used as well for targeting imaging. In the present study we evaluated the potential of using LHM to detect changes in stiffness and the feasibility of using it for imaging purposes in phantoms and in vivo tumor detection. A single-element FUS transducer (80 mm focal length, 100 mm diameter, 1.485 MHz) was used for inducing a localized harmonic motion and a separate ultrasound diagnostic transducer excited by a pulser/receiver (5 kHz PRF, 5 MHz) was used to track motion. The motion was estimated using cross-correlation techniques on the acquired RF signal. Silicon phantom studies were performed in order to determine the size of inclusion that was possible to detect using this technique. Inclusions were discerned from the surroundings as a reduction on LHM amplitude and it was possible to depict inclusions as small as 4 mm. The amplitude of the induced LHM was always lower at the inclusions as compared with the one obtained at the surroundings. Ten New Zealand rabbits had VX2 tumors implanted on their thighs and LHM was induced and measured at the tumor region. Tumors (as small as 10 mm in length and 4 mm in width) were discerned from the surroundings as a reduction on LHM amplitude. PMID:21683514

  9. Development, Characterization, and Implementation of a System for Focused Ultrasound-Mediated Blood-Brain Barrier Opening in Mice

    NASA Astrophysics Data System (ADS)

    Valdez, Michael Aaron

    The blood-brain barrier BBB refers to the set of specialized endothelial cells that line the vasculature in the brain and effectively control movement of molecules into and out of the brain. While necessary for proper brain function, the BBB blocks 98% of drugs from entering the brain and is the most significant barrier to developing therapies for neurodegenerative diseases. Active transport allows some specific molecules to cross the BBB, but therapeutic development using this route has had limited success. A number of techniques have been used to bypass the BBB, but are often highly invasive and ineffective. Over the last two decades, a minimally invasive technique to transiently open the BBB has been under development that utilizes transcranial focused ultrasound (FUS) in combination with intravascular microbubble contrast agents. This method is often carried out in conjunction with magnetic resonance imaging (MRI) to guide and assess BBB opening and has been referred to as MRI guided FUS (MRgFUS). Because of the utility of mouse models of neurological disease and the exploratory nature of MRgFUS, systems that allow BBB opening in mice are a useful and necessary tool to develop and evaluate this method for clinical application. In this dissertation project, a custom built, cost-effective FUS system for opening the BBB in mice was developed, with the objective of using this device to deliver therapeutics to the brain. Being a custom device, it was necessary to evaluate the ultrasound output, verify in vivo safety, and anticipate the therapeutic effect. The scope of the work herein consists of the design, construction, and evaluation of system that fulfills these requirements. The final constructed system cost was an order of magnitude less than any commercially available MRgFUS system. At this low price point, the hardware could allow the implementation of the methodology in many more research areas than previously possible. Additionally, to anticipate the

  10. Osteoid osteoma: Magnetic resonance guided high intensity focused ultrasound for entirely non-invasive treatment. A prospective developmental study

    NASA Astrophysics Data System (ADS)

    Napoli, A.; de Soccio, V.; Cartocci, G.; Boni, F.; Anzidei, M.; Catalano, C.

    2017-03-01

    To determine the effect of acoustic energy delivered during MR guided Focused Ultrasound (MRgFUS) treatment of symptomatic osteoid osteomas. This prospective, IRB approved study involved 15 consecutive patients (11 m; 4f; mean age, 21) with clinical and imaging diagnosis of Osteoid Osteoma; all patients underwent MRgFUS ablation (ExAblate, InSightec; Discovery 750 MR unit, GE). Lesions located in the vertebral body were excluded, while lesions in proximity to joints or neurovascular bundles were included. Treatment success was determined at clinical and imaging follow-up at 1, 6 and 12 months post-treatment. A visual Analog Pain Score (VAS) was used to assess changes in symptoms. Bone changes at nidus site were evaluated on the basis of CT and dynamic ce-MR imaging (Gd-Bopta; Bracco) pre- and post-treatment. Treatment was carried out using a variable number of sonications (mean 4±1.8) with a mean energy deposition of 866±211 J. There were no treatment- or anesthesia-related complications. A statistically significant (p=0.001) difference was noted between the overall pre- and post-treatment mean VAS scores (8.3±1.6 and 0.6±1.5, respectively). Two treatments were conducted in patients with prior CTgRFA failure and needed two different session for achieving complete clinical successful. At imaging, edema and hyperemia associated with typical osteoid osteoma, gradually disappeared in all lesions. No apparent relationship between nidus vascular extinction and successful outcome was found. Variable reabsorption degree of sclerotic reaction was observed with nidus disappearance in 4 cases (27%). Treatment of osteoid osteoma using MR guided Focused Ultrasound can be performed safely with a high rate of success and without treatment related morbidity; our results indicated also a positive trend to bone rearrangement after treatment.

  11. New piezocrystal material in the development of a 96-element array transducer for MR-guided focused ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Qiu, Zhen; Habeshaw, Roderick; Fortine, Julien; Huang, Zhihong; Démoré, Christine; Cochran, Sandy

    2012-11-01

    Piezocrystal materials have been recognized as having better performance than piezoelectric ceramics, and have thus been widely adopted in ultrasound imaging arrays. Although their behaviour is susceptible to temperature and pressure, their large electromechanical coupling coefficients and other excellent piezoelectric properties also offer the potential for further improvements in the efficiency of therapeutic ultrasound transducers. Furthermore, new piezocrystals with modified compositions have been developed recently to increase their tolerance to temperature and pressure. In this work, a prototype of faceted bowl transducer was designed and manufactured as a proof of concept to explore practical issues associated with adoption of piezocrystals for magnetic resonance imaging guided focused ultrasound surgery.

  12. Multi-depth fractionated aesthetic ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Slayton, Michael H.; Lyke, Stephanie; Barthe, Peter G.

    2017-03-01

    Objective: Aesthetic ultrasound surgery provides the ability to treat at precise, clinically relevant depths with varied lesion size. This represents a major advantage compared to cosmetic laser and RF based energy sources. We present results of pre-clinical and clinical research aimed at establishing the feasibility of three-dimensional fractional deposition of focused ultrasound energy in the first 3mm of skin. Conformal thermal lesions were created in ex-vivo porcine muscle and live human skin in a variety of depths and geometries. Gross pathology demonstrating a three-dimensional pattern of non-intersecting lesions was micro- photographed and characterized in porcine tissue, and followed up to thirty days post treatment in human tissue. Methods: Image/treat transducers from 7.5 to 10 MHz, focal depths of 1 to 3 mm, and energies of 160 to 300 mJ were used to lay down a three-dimensional pattern of non-intersecting thermal lesions in freshly excised porcine muscle tissue. Human skin was treated in vivo at 120 to 360 mJ per lesion. Results were photographed immediately post-treatment and followed up to 30 days. Results: Porcine tissue lesion geometry was measured. Average lesion dimensions approximated by a sphere ranged from 360 micron (±19%) to 520 micron (±23%) varying with the energy settings. Measured depth and distance between the thermal lesions were within ±13% of the focal depth and lesion spacing. In human skin all lesions for all energy settings were completely resolved during the follow-up period. At lower energy settings of 120 mJ and 160 mJ lesions were completely resolved by day 2. Mild erythema and localized swelling were the only transient side effects and resolved within 48 hours or less. Conclusions: In conclusion, skin may be successfully treated in a three-dimensional fractionated manner with predictable and precise deposition of thermal damage. In vivo results demonstrate tolerability and fast resolution with minimal side effects.

  13. A randomised, controlled, double-blind trial of ultrasound-guided phrenic nerve block to prevent shoulder pain after thoracic surgery.

    PubMed

    Blichfeldt-Eckhardt, M R; Laursen, C B; Berg, H; Holm, J H; Hansen, L N; Ørding, H; Andersen, C; Licht, P B; Toft, P

    2016-12-01

    Moderate to severe ipsilateral shoulder pain is a common complaint following thoracic surgery. In this prospective, parallel-group study at Odense University Hospital, 76 patients (aged > 18 years) scheduled for lobectomy or pneumonectomy were randomised 1:1 using a computer-generated list to receive an ultrasound-guided supraclavicular phrenic nerve block with 10 ml ropivacaine or 10 ml saline (placebo) immediately following surgery. A nerve catheter was subsequently inserted and treatment continued for 3 days. The study drug was pharmaceutically pre-packed in sequentially numbered identical vials assuring that all participants, healthcare providers and data collectors were blinded. The primary outcome was the incidence of unilateral shoulder pain within the first 6 h after surgery. Pain was evaluated using a numeric rating scale. Nine of 38 patients in the ropivacaine group and 26 of 38 patients in the placebo group experienced shoulder pain during the first 6 h after surgery (absolute risk reduction 44% (95% CI 22-67%), relative risk reduction 65% (95% CI 41-80%); p = 0.00009). No major complications, including respiratory compromise or nerve injury, were observed. We conclude that ultrasound-guided supraclavicular phrenic nerve block is an effective technique for reducing the incidence of ipsilateral shoulder pain after thoracic surgery. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  14. [Ultrasound-guided cutaneous intercostal branches nerves block: A good analgesic alternative for gallbladder open surgery].

    PubMed

    Fernández Martín, M T; López Álvarez, S; Mozo Herrera, G; Platero Burgos, J J

    2015-12-01

    Laparoscopic cholecystectomy has become the standard treatment for gallbladder diseases. However, there are still some patients for whom conversion to open surgery is required. This surgery can produce significant post-operative pain. Opioids drugs have traditionally been used to treat this pain, but side effects have led to seeking alternatives (plexus, nerve or fascia blocks or wound). The cases are presented of 4 patients subjected to ultrasound-guided intercostal branches blocks in the mid-axillary line from T6 to T12 with levobupivacaine as an analgesic alternative in open surgery of gallbladder, with satisfactory results. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Custom molded thermal MRg-FUS phantom

    NASA Astrophysics Data System (ADS)

    Eames, Matthew D. C.; Snell, John W.; Hananel, Arik; Kassell, Neal F.

    2012-11-01

    This article describes a method for creating custom-molded thermal phantoms for use with MR-guided focused ultrasound systems. The method is defined here for intracranial applications, though it may be modified for other anatomical targets.

  16. Simulating thermal effects of MR-guided focused ultrasound in cortical bone and its surrounding tissue.

    PubMed

    Hudson, Thomas J; Looi, Thomas; Pichardo, Samuel; Amaral, Joao; Temple, Michael; Drake, James M; Waspe, Adam C

    2018-02-01

    Magnetic resonance-guided focused ultrasound (MRgFUS) is emerging as a treatment alternative for osteoid osteoma and painful bone metastases. This study describes a new simulation platform that predicts the distribution of heat generated by MRgFUS when applied to bone tissue. Calculation of the temperature distribution was performed using two mathematical models. The first determined the propagation and absorption of acoustic energy through each medium, and this was performed using a multilayered approximation of the Rayleigh integral method. The ultrasound energy distribution derived from these equations could then be converted to heat energy, and the second mathematical model would then use the heat generated to determine the final temperature distribution using a finite-difference time-domain application of Pennes' bio-heat transfer equation. Anatomical surface geometry was generated using a modified version of a mesh-based semiautomatic segmentation algorithm, and both the acoustic and thermodynamic models were calculated using a parallelized algorithm running on a graphics processing unit (GPU) to greatly accelerate computation time. A series of seven porcine experiments were performed to validate the model, comparing simulated temperatures to MR thermometry and assessing spatial, temporal, and maximum temperature accuracy in the soft tissue. The parallelized algorithm performed acoustic and thermodynamic calculations on grids of over 10 8 voxels in under 30 s for a simulated 20 s of heating and 40 s of cooling, with a maximum time per calculated voxel of less than 0.3 μs. Accuracy was assessed by comparing the soft tissue thermometry to the simulation in the soft tissue adjacent to bone using four metrics. The maximum temperature difference between the simulation and thermometry in a region of interest around the bone was measured to be 5.43 ± 3.51°C average absolute difference and a percentage difference of 16.7%. The difference in heating location

  17. Automatic bone detection and soft tissue aware ultrasound-CT registration for computer-aided orthopedic surgery.

    PubMed

    Wein, Wolfgang; Karamalis, Athanasios; Baumgartner, Adrian; Navab, Nassir

    2015-06-01

    The transfer of preoperative CT data into the tracking system coordinates within an operating room is of high interest for computer-aided orthopedic surgery. In this work, we introduce a solution for intra-operative ultrasound-CT registration of bones. We have developed methods for fully automatic real-time bone detection in ultrasound images and global automatic registration to CT. The bone detection algorithm uses a novel bone-specific feature descriptor and was thoroughly evaluated on both in-vivo and ex-vivo data. A global optimization strategy aligns the bone surface, followed by a soft tissue aware intensity-based registration to provide higher local registration accuracy. We evaluated the system on femur, tibia and fibula anatomy in a cadaver study with human legs, where magnetically tracked bone markers were implanted to yield ground truth information. An overall median system error of 3.7 mm was achieved on 11 datasets. Global and fully automatic registration of bones aquired with ultrasound to CT is feasible, with bone detection and tracking operating in real time for immediate feedback to the surgeon.

  18. Focal therapy for localized unifocal and multifocal prostate cancer: A prospective development study using real time MR guided focused ultrasound

    NASA Astrophysics Data System (ADS)

    Napoli, A.; Caliolo, G.; Boni, F.; Anzidei, M.; Catalano, C.

    2017-03-01

    To assess safety and feasibility of non-invasive high intensity 3T MR guided focused ultrasound (MRgFUS) treatment of localized prostate cancer in an exploratory designed study. Men aged 45-80 years were eligible for this prospective study if they had low-risk localized prostate cancer (prostate specific antigen [PSA] ≤10 ng/mL, Gleason score ≤ 3 + 3), with no previous androgen deprivation or treatment for prostate cancer, and who could safely undergo multiparametric MRI (Discovery 750, GE; Gd-Bopta, Bracco) and have a spinal anesthetic. Patients underwent focal therapy using real time MR guided high intensity focused ultrasound (MRgFUS), delivered to all known cancer lesions, with a margin of normal tissue. Primary endpoints were adverse events (serious and otherwise) and urinary symptoms and erectile function assessed using patient questionnaires. 8 men were recruited between June 2011 and June 2012. After treatment, one man was admitted to hospital for acute urinary retention. Another patient had self-resolving, mild, intermittent dysuria (median duration 5.0 days). Urinary tract infection was not reported. Urinary debris occurred in 6 men (75%), with a median duration of 12 days. Median overall International Index of Erectile Function-15 (IIEF-15) scores were similar at baseline and at 6 to 12 months (p=0.060), as were median IIEF-15 scores for intercourse satisfaction (p=0.433), sexual desire (p=0.622), and overall satisfaction (p=0.256). There was an improvement in lower urinary tract symptoms, assessed by International Prostate Symptom Score (IPSS), between baseline and 6 to 12 months (p=0.026). All 8 men with no baseline urinary incontinence were leak-free and pad-free by 9 months. No histological evidence of cancer was identified in 7 of 8 men biopsied at 6 months (87,5%); overall, the entire population (8 patients) was free of clinically significant cancer and had no evidence of disease on multi-parametric MRI at 6 to 12 months. MR guided Focused

  19. Intraoperative Ultrasound Guidance in Breast-Conserving Surgery Improves Cosmetic Outcomes and Patient Satisfaction: Results of a Multicenter Randomized Controlled Trial (COBALT).

    PubMed

    Haloua, Max H; Volders, José H; Krekel, Nicole M A; Lopes Cardozo, Alexander M F; de Roos, Wifred K; de Widt-Levert, Louise M; van der Veen, Henk; Rijna, Herman; Bergers, Elisabeth; Jóźwiak, Katarzyna; Meijer, Sybren; van den Tol, Petrousjka

    2016-01-01

    Ultrasound-guided breast-conserving surgery (USS) results in a significant reduction in both margin involvement and excision volumes (COBALT trial). Objective. The aim of the present study was to determine whether USS also leads to improvements in cosmetic outcome and patient satisfaction when compared with standard palpation-guided surgery (PGS). A total of 134 patients with T1–T2 invasive breast cancer were included in the COBALT trial (NTR2579) and randomized to either USS (65 patients) or PGS (69 patients). Cosmetic outcomes were assessed by a three-member panel using computerized software Breast Cancer Conservative Treatment cosmetic results (BCCT.- core) and by patient self-evaluation, including patient satisfaction. Time points for follow-up were 3, 6, and 12 months after surgery. Overall cosmetic outcome and patient satisfaction were scored on a 4-point Likert scale (excellent, good, fair, or poor), and outcomes were analyzed using a multilevel, mixed effect, proportional odds model for ordinal responses. Ultrasound-guided breast-conserving surgery achieved better cosmetic outcomes, with 20 % excellence overall and only 6 % rated as poor, whereas 14 % of PGS outcomes were rated excellent and 13 % as poor. USS also had consistently lower odds for worse cosmetic outcomes (odds ratio 0.55, p = 0.067) than PGS. The chance of having a worse outcome was significantly increased by a larger lumpectomy volume (ptrend = 0.002); a volume [40 cc showed odds 2.78-fold higher for a worse outcome than a volume B40 cc. USS resulted in higher patient satisfaction compared with PGS. Ultrasound-guided breast-conserving surgery achieved better overall cosmetic outcomes and patient satisfaction than PGS. Lumpectomy volumes[40 cc resulted in significantly worse cosmetic outcomes.

  20. Target vessel detection by epicardial ultrasound in off-pump coronary bypass surgery.

    PubMed

    Hayakawa, Masato; Asai, Tohru; Kinoshita, Takeshi; Suzuki, Tomoaki; Shiraishi, Shoichiro

    2013-01-01

    The detection of embedded coronary arteries is difficult especially in off-pump coronary bypass surgery. From June 2010, we introduced high-frequency epicardial ultrasound (ECUS) to assess and evaluate embedded arteries during off-pump coronary bypass surgery. Between June 2010 and June 2011, a total of 89 consecutive patients underwent isolated coronary bypass surgery at our institution. The patients consisted of 72 men and 17 women with a mean age of 67.9 years. We routinely use the VeriQC system (MediStim, Oslo, Norway) to detect the target vessels in the operation. The patients were assigned to one of two groups, depending on whether ECUS was used in the operation (n = 10, ECUS group) or not (n = 79, non-ECUS group). We analyzed the impact of introducing the ECUS in terms of operative outcome. All patients underwent revascularization using the off-pump technique without emergent conversion to cardiopulmonary bypass during surgery. The total number of distal anastomoses was 299, and 12 target vessels could not be identified either visually or on palpation. Thus, the frequency of the embedded coronary arteries was 4.01% (12/299 cases). The preoperative profiles of the two groups were not significantly different. Operation time was significantly longer in the ECUS group (P = 0.02). There were no significant differences in postoperative outcome between the two groups. In the present study, in which the target coronary arteries could not be detected either visually or on palpation in 12 (4.01%) of 299 cases, the use of high-frequency ECUS allowed all patients to undergo off-pump coronary bypass surgery without conversion to cardiopulmonary bypass during the operation. High-frequency ECUS is therefore useful in off-pump coronary bypass surgery.

  1. Elevated cranial ultrasound resistive indices are associated with improved neurodevelopmental outcomes one year after pediatric cardiac surgery: A single center pilot study.

    PubMed

    Jenks, Christopher L; Hernandez, Ana; Stavinoha, Peter L; Morris, Michael C; Tian, Fenghua; Liu, Hanli; Garg, Parvesh; Forbess, Joseph M; Koch, Joshua

    To determine if a non-invasive, repeatable test can be used to predict neurodevelopmental outcomes in patients with congenital heart disease. This was a prospective study of pediatric patients less than two months of age undergoing congenital heart surgery at the Children's Health Children's Medical Center at Dallas. Multichannel near-infrared spectroscopy (NIRS) was utilized during the surgery, and ultrasound (US) resistive indices (RI) of the major cranial vessels were obtained prior to surgery, immediately post-operatively, and prior to discharge. Pearson's correlation, Fischer exact t test, and Fischer r to z transformation were used where appropriate. A total of 16 patients were enrolled. All had US data. Of the sixteen patients, two died prior to the neurodevelopmental testing, six did not return for the neurodevelopmental testing, and eight patients completed the neurodevelopmental testing. There were no significant correlations between the prior to surgery and prior to discharge US RI and neurodevelopmental outcomes. The immediate post-operative US RI demonstrated a strong positive correlation with standardized neurodevelopmental outcome measures. We were able to demonstrate qualitative differences using multichannel NIRS during surgery, but experienced significant technical difficulties implementing consistent monitoring. A higher resistive index in the major cerebral blood vessels following cardiac surgery in the neonatal period is associated with improved neurological outcomes one year after surgery. Obtaining an ultrasound with resistive indices of the major cerebral vessels prior to and after surgery may yield information that is predictive of neurodevelopmental outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Prognostic value of three-dimensional ultrasound for fetal hydronephrosis

    PubMed Central

    WANG, JUNMEI; YING, WEIWEN; TANG, DAXING; YANG, LIMING; LIU, DONGSHENG; LIU, YUANHUI; PAN, JIAOE; XIE, XING

    2015-01-01

    The present study evaluated the prognostic value of three-dimensional ultrasound for fetal hydronephrosis. Pregnant females with fetal hydronephrosis were enrolled and a novel three-dimensional ultrasound indicator, renal parenchymal volume/kidney volume, was introduced to predict the postnatal prognosis of fetal hydronephrosis in comparison with commonly used ultrasound indicators. All ultrasound indicators of fetal hydronephrosis could predict whether postnatal surgery was required for fetal hydronephrosis; however, the predictive performance of renal parenchymal volume/kidney volume measurements as an individual indicator was the highest. In conclusion, ultrasound is important in predicting whether postnatal surgery is required for fetal hydronephrosis, and the three-dimensional ultrasound indicator renal parenchymal volume/kidney volume has a high predictive performance. Furthermore, the majority of cases of fetal hydronephrosis spontaneously regress subsequent to birth, and the regression time is closely associated with ultrasound indicators. PMID:25667626

  3. MO-DE-202-01: Image-Guided Focused Ultrasound Surgery and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farahani, K.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41

  4. Ultrasound Vein and Artery Mapping by General Surgery Residents During Initial Consult Can Decrease Time to Dialysis Access Creation.

    PubMed

    Gray, Kelsey; Korn, Abraham; Zane, Joshua; Gonzalez, Gabriel; Kaji, Amy; Bowens, Nina; de Virgilio, Christian

    2018-05-01

    Formal preoperative ultrasound (US) mapping of vascular anatomy by radiology is recommended before hemodialysis access surgery. We hypothesized that US performed by general surgery residents in place of formal US would decrease the time from initial consult to creation of dialysis access without affecting patient outcomes. This is a retrospective review of all patients who underwent dialysis access surgery from November 2014 to July 2016 and received preoperative upper extremity US vein and artery evaluation by either radiology or general surgery residents. The primary endpoints were days from initial consult to dialysis access creation, rate of arteriovenous fistula (AVF) creation, fistula maturation, and 1-year primary assisted patency. Of 242 patients, 167 (69%) had formal US, and 75 (31%) had only a resident US. The resident US group had 100% AVF creation compared with the formal US group with 92.2% AVF creation (P = 0.01). There was no difference between the groups in rate of fistula maturation (P = 0.1) and 1-year assisted patency (P = 0.9). Of the resident US 90.7% occurred in the outpatient setting. On multivariable analysis controlling for outpatient consult, the average time to the operating room was 13.7 days longer for the formal US group in the outpatient setting (P = 0.0006). Ultrasound vein and artery evaluation at the time of the initial consult by general surgery residents can decrease the time to dialysis access creation by bypassing the need for formal US with a higher rate of AVF creation and no difference in fistula maturation or 1-year primary assisted patency. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. The role of ultrasound in the management of flexor tendon injuries.

    PubMed

    Jeyapalan, K; Bisson, M A; Dias, J J; Griffin, Y; Bhatt, R

    2008-08-01

    The use of ultrasound scanning to establish tendon pathologies was assessed retrospectively in 17 patients in 18 digits. The ultrasound scan demonstrated four patterns: (1) normal intact tendons in four, (2) ruptured tendons in three, (3) tendons in continuity but attenuated in five and (4) tendons in continuity but thickened with fibrosis and decreased movement representing adhesions in five patients. Surgery was undertaken in only three cases, confirming the ultrasound diagnosis in two. Surgery was offered to all three patients with ruptures but was declined by two. Ultrasound imaging helped to avoid surgery in 14 cases by excluding flexor tendon re-ruptures. This allowed on-going mobilisation, leading to recovery of function.

  6. [Ultrasound guided percutaneous nephrolithotripsy].

    PubMed

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  7. A prospective trial of magnetic resonance-guided focused ultrasound thalamotomy for essential tremor: Results at the 2-year follow-up.

    PubMed

    Chang, Jin Woo; Park, Chang Kyu; Lipsman, Nir; Schwartz, Michael L; Ghanouni, Pejman; Henderson, Jaimie M; Gwinn, Ryder; Witt, Jennifer; Tierney, Travis S; Cosgrove, G Rees; Shah, Binit B; Abe, Keiichi; Taira, Takaomi; Lozano, Andres M; Eisenberg, Howard M; Fishman, Paul S; Elias, W Jeffrey

    2018-01-01

    Magnetic resonance guided focused ultrasound (MRgFUS) has recently been investigated as a new treatment modality for essential tremor (ET), but the durability of the procedure has not yet been evaluated. This study reports results at a 2- year follow-up after MRgFUS thalamotomy for ET. A total of 76 patients with moderate-to-severe ET, who had not responded to at least two trials of medical therapy, were enrolled in the original randomized study of unilateral thalamotomy and evaluated using the clinical rating scale for tremor. Sixty-seven of the patients continued in the open-label extension phase of the study with monitoring for 2 years. Nine patients were excluded by 2 years, for example, because of alternative therapy such as deep brain stimulation (n = 3) or inadequate thermal lesioning (n = 1). However, all patients in each follow-up period were analyzed. Mean hand tremor score at baseline (19.8 ± 4.9; 76 patients) improved by 55% at 6 months (8.6 ± 4.5; 75 patients). The improvement in tremor score from baseline was durable at 1 year (53%; 8.9 ± 4.8; 70 patients) and at 2 years (56%; 8.8 ± 5.0; 67 patients). Similarly, the disability score at baseline (16.4 ± 4.5; 76 patients) improved by 64% at 6 months (5.4 ± 4.7; 75 patients). This improvement was also sustained at 1 year (5.4 ± 5.3; 70 patients) and at 2 years (6.5 ± 5.0; 67 patients). Paresthesias and gait disturbances were the most common adverse effects at 1 year-each observed in 10 patients with an additional 5 patients experiencing neurological adverse effects. None of the adverse events worsened over the period of follow-up, and 2 of these resolved. There were no new delayed complications at 2 years. Tremor suppression after MRgFUS thalamotomy for ET is stably maintained at 2 years. Latent or delayed complications do not develop after treatment. Ann Neurol 2018;83:107-114. © 2017 American Neurological Association.

  8. Nanobiotechnology promotes noninvasive high-intensity focused ultrasound cancer surgery.

    PubMed

    Chen, Yu; Chen, Hangrong; Shi, Jianlin

    2015-01-07

    The successful cancer eradication in a noninvasive manner is the ultimate objective in the fight against cancer. As a "bloodless scalpel," high-intensity focused ultrasound (HIFU) is regarded as one of the most promising and representative noninvasive therapeutic modalities for cancer surgery. However, large-scale clinical applications of HIFU are still in their infancy because of critical efficiency and safety issues which remain to be solved. Fortunately, recently developed nanobiotechnology provides an alternative efficient approach to improve such important issues in HIFU, especially for cancer therapy. This Research News presents the very recent exciting progresses on the elaborate design and fabrication of organic, inorganic, and organic/inorganic hybrid nanoparticles for enhancing the HIFU ablation efficiency against tumor tissues. It is highly expected that this Research News can arouse more extensive research enthusiasm on the development of functional nanomaterials for highly efficient HIFU-based synergistic therapy, which will give a promising noninvasive therapeutic modality for the successful cancer therapy with minimal damage to surrounding normal tissues, due to the noninvasive and site-specific therapeutic features of HIFU. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. FFT-based computation of the bioheat transfer equation for the HCC ultrasound surgery therapy modeling.

    PubMed

    Dillenseger, Jean-Louis; Esneault, Simon; Garnier, Carole

    2008-01-01

    This paper describes a modeling method of the tissue temperature evolution over time in hyperthermia. More precisely, this approach is used to simulate the hepatocellular carcinoma curative treatment by a percutaneous high intensity ultrasound surgery. The tissue temperature evolution over time is classically described by Pennes' bioheat transfer equation which is generally solved by a finite difference method. In this paper we will present a method where the bioheat transfer equation can be algebraically solved after a Fourier transformation over the space coordinates. The implementation and boundary conditions of this method will be shown and compared with the finite difference method.

  10. Conventional versus ultrasound-assisted liposuction in gynaecomastia surgery: a 13-year review.

    PubMed

    Wong, Kai Yuen; Malata, Charles M

    2014-07-01

    Numerous surgical techniques exist for gynaecomastia treatment. Although ultrasound-assisted liposuction (UAL) is thought to be more effective than conventional liposuction, to date there remains no objective and direct comparison of the two modalities. Hence, a comparative study was performed of a single surgeon's experience over 13 years using two definitive parameters, namely intraoperative conversion to open excision and postoperative revisional surgery rates. All gynaecomastia patients treated with UAL or conventional liposuction (1999-2012) were retrospectively studied. UAL was only available in the private sector and was used for all such patients with no other selection or exclusion criteria. A total of 219 patients (384 breasts) with a mean age of 29 years (range 12-74) were evaluated. UAL was utilised in 24% of breasts (47 patients, 91 breasts). Compared with conventional liposuction, UAL had significantly lower rates of intraoperative conversion to open excision (25% vs. 39%; p<0.05) and postoperative revision (2% vs. 19%; p<0.001) using Fisher's exact test. The haematoma rate for each technique was 1%. UAL is a more effective treatment modality for gynaecomastia than conventional liposuction as determined by intraoperative conversion to open surgery and subsequent need for revision. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that uses...

  12. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that uses...

  13. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that uses...

  14. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that uses...

  15. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that uses...

  16. [An application of low-invasive access in ultrasound-guided surgery of liquid formation of the abdominal cavity and retroperitoneal space].

    PubMed

    Demin, D B; Laĭkov, A V; Funygin, M S; Chegodaeva, A A; Solodov, Iu Iu; Butina, K V

    2014-01-01

    The article presents a low-invasive method in the intraoperative ultrasound-guided surgery. The method had several steps: an access (2-3 cm) was made to a liquid formation with the following aspiration of contents, a necrotic detritus was removed through the wound tract using simultaneous ultrasound examination of efficacy of emptying the cavity with drainage. This means allowed the performance of single-stage sanitization and drainage of cavity formations, which contained the liquid and dense necrotic tissues in the lumen. The method was effective, technically workable in any surgical hospital. At the same time, it was economically reasonable, because there wasn't need to buy an additional equipment. The application of the means considerably shortened a hospital stay and the lethality was reduced.

  17. B-Mode ultrasound pose recovery via surgical fiducial segmentation and tracking

    NASA Astrophysics Data System (ADS)

    Asoni, Alessandro; Ketcha, Michael; Kuo, Nathanael; Chen, Lei; Boctor, Emad; Coon, Devin; Prince, Jerry L.

    2015-03-01

    Ultrasound Doppler imaging may be used to detect blood clots after surgery, a common problem. However, this requires consistent probe positioning over multiple time instances and therefore significant sonographic expertise. Analysis of ultrasound B-mode images of a fiducial implanted at the surgical site offers a landmark to guide a user to the same location repeatedly. We demonstrate that such an implanted fiducial may be successfully detected and tracked to calculate pose and guide a clinician consistently to the site of surgery, potentially reducing the ultrasound experience required for point of care monitoring.

  18. Initial laboratory experience with a novel ultrasound probe for standard and single-port robotic kidney surgery: increasing console surgeon autonomy and minimizing instrument clashing.

    PubMed

    Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H

    2012-06-01

    The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.

  19. [Ultrasound-assisted approach to blocking the intercostal nerves in the mid-axillary line for non-reconstructive breast and axilla surgery].

    PubMed

    Diéguez García, P; Fajardo Pérez, M; López Álvarez, S; Alfaro de la Torre, P; Pensado Castiñeiras, A P

    2013-01-01

    Several nerve blocks have recently been used for pain treatment in breast surgery. The main objective of our study was to determine the efficacy and safety of ultrasound-assisted blocking of the anterior and lateral cutaneous branches of the intercostal nerves in the mid-axillary line for non-reconstructive breast and axilla surgery. A prospective observational study was conducted on 30 patients scheduled for non-reconstructive breast and axilla surgery. An intercostal branches block was performed in the mid-axillary line with 0,5% levobupivacaine (3ml in each intercostal space). Clinical efficacy was assessed by standard intraoperative hemodynamic response to surgical stimulus and the need for opioids, and in the postoperative period, by assessing pain intensity as a verbal numerical scale and the need for rescue treatment. We also evaluated the quality of sleep the first night after surgery, any adverse events that occurred, and the satisfaction of patients and surgeons with the anesthetic technique. The intercostal branches block in the mid-axillary line was effective in most cases, with only 2 patients requiring intraoperative opioids, and in one case analgesic rescue was necessary in the postoperative period. The duration of postoperative analgesia was 19±4h. There were no notable adverse events or complications. The satisfaction with the chosen technique was assessed as "very good" in all patients, and by 97% of the surgeons. Intercostal branches block in the mid-axillary line provides adequate intraoperative and postoperative analgesia for non-reconstructive breast and axilla surgery. It is a simple, reproducible technique in most patients of this study, with an easy to understand ultrasound anatomy, in which adequate analgesia could be provided through a single puncture, and may be an alternative to neuroaxial blocks. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights

  20. Effects of preoperative ultrasound-guided transversus abdominis plane block on pain after laparoscopic surgery for colorectal cancer: a double-blind randomized controlled trial.

    PubMed

    Oh, Tak Kyu; Yim, Jiyeon; Kim, Jaehyun; Eom, Woosik; Lee, Soon Ae; Park, Sung Chan; Oh, Jae Hwan; Park, Ji Won; Park, Boram; Kim, Dae Hyun

    2017-01-01

    Although laparoscopic colorectal surgery decreases postoperative pain and facilitates a speedier recovery compared with laparotomy, postoperative pain at trocar insertion sites remains a clinical concern. The objective of this study was to assess the effects of a preoperative ultrasound-guided transversus abdominis plane (TAP) block on pain after laparoscopic surgery for colorectal cancer. In total, 58 patients scheduled to undergo laparoscopic surgery following a diagnosis of colorectal cancer were included in this study. The patients were randomized into TAP and control groups; the TAP group patients received a preoperative ultrasound-guided bilateral TAP block with 0.5 mL/kg of 0.25 % bupivacaine, while the control patients received the block with an equal amount of saline. Pain on coughing and at rest was assessed during postanesthetic recovery (PAR; 1 h after surgery) and on postoperative days (PODs) 1 (24 h), 2 (48 h), and 3 (72 h) by an investigator blinded to group allocations using the numeric rating scale (NRS). The primary outcome was pain on coughing on postoperative day (POD) 1. Fifty-five patients were included in the final analysis, including 28 in the TAP and 27 in the control groups. The pain intensity on coughing and at rest during PAR and on PODs 1, 2, and 3 showed no significant differences between groups. Furthermore, there was no significant difference in postoperative opioid consumption, sedation scores, nausea scores at the four time points, complication rates, and length of hospital stay between groups. In colorectal cancer patients undergoing laparoscopic colorectal surgery, a TAP block did not offer enough benefit for clinical efficacy in terms of postoperative pain or analgesic consumption.

  1. Preoperative ultrasound measurements predict the feasibility of gallbladder extraction during transgastric natural orifice translumenal endoscopic surgery cholecystectomy.

    PubMed

    Santos, Byron F; Auyang, Edward D; Hungness, Eric S; Desai, Kush R; Chan, Edward S; van Beek, Darren B; Wang, Edward C; Soper, Nathaniel J

    2011-04-01

    Extraction of a gallbladder through an endoscopic overtube during natural orifice translumenal endoscopic surgery (NOTES) transgastric cholecystectomy avoids potential injury to the esophagus. This study examined the rate of successful gallbladder specimen extraction through an overtube and hypothesized that preoperative ultrasound findings could predict successful specimen passage. Gallbladder specimens from patients undergoing laparoscopic cholecystectomy were measured, and an attempt was made to pull the specimens through a commercially available overtube with an inner diameter of 16.7-mm. A radiologist blinded to the outcomes reviewed the available preoperative ultrasound measurements from these patients. Ultrasound dimensions including gallbladder length, width, and depth; wall thickness; common bile duct diameter; and size of the largest gallstone (LGS) were recorded. Multiple logistic regression analysis was performed to determine whether ultrasound findings and patient characteristics (age, body mass index [BMI], and sex) could predict the ability of a specimen to pass through the overtube. Of 57 patients, 44 (77%) who had preoperative ultrasounds available for electronic review were included in the final analysis. Gallstones were present in 35 (79%) of these 44 patients. Intraoperative gallbladder perforation occurred in 18 (41%) of the 44 patients, and 16 (36%) of the 44 gallbladders could be extracted through the overtube. Measurement of LGS was possible for 23 patients, and indeterminate gallstone size (IGS) was determined for 12 patients. The rate for passage of perforated versus intact gallbladders was similar (40% vs. 23%; p = 0.054). The LGS (odds ratio [OR], 1.17; 95% confidence interval [CI], 1.02-1.33; p = 0.021) and IGS (OR, 22.97; 95% CI, 1.99-265.63; p = 0.025) predicted failed passage on multivariate logistic regression analysis. The passage rate was 80% for LGS smaller than 10 mm or no stones present, 18% for LGS 10 mm or larger, and 8% for

  2. Image-Guided Surgery of Primary Breast Cancer Using Ultrasound Phased Arrays

    DTIC Science & Technology

    2004-07-01

    applications using high-intensity focused ultrasound ( HIFU ). We tems, Once the real-time imaging capability is available for have shown that this dual-mode...Arrays Emad S. Ebbini, PI Introduction High-intensity focus ultrasound ( HIFU ) is gaining wider acceptance in noninvasive or minimally invasive targeting of...Methods in Ultrasound Imaging, ISBI 2004, Arlington, VA, April 2004. III. Yao and Ebbini, "Real-Time Monitoring of the Transients of HIFU -Induced Lesions

  3. Outcome of appendicectomy in children performed in paediatric surgery units compared with general surgery units.

    PubMed

    Tiboni, S; Bhangu, A; Hall, N J

    2014-05-01

    Appendicectomy for acute appendicitis in children may be performed in specialist centres by paediatric surgeons or in general surgery units. Service provision and outcome of appendicectomy in children may differ between such units. This multicentre observational study included all children (aged less than 16 years) who had an appendicectomy at either a paediatric surgery unit or general surgery unit. The primary outcome was normal appendicectomy rate (NAR). Secondary outcomes included 30-day adverse events, use of ultrasound imaging and laparoscopy, and consultant involvement in procedures. Appendicectomies performed in 19 paediatric surgery units (242 children) and 54 general surgery units (461 children) were included. Children treated in paediatric surgery units were younger and more likely to have a preoperative ultrasound examination, a laparoscopic procedure, a consultant present at the procedure, and histologically advanced appendicitis than children treated in general surgery units. The unadjusted NAR was significantly lower in paediatric surgery units (odds ratio (OR) 0.37, 95 per cent confidence interval 0.23 to 0.59; P < 0.001), and the difference persisted after adjusting for age, sex and use of preoperative ultrasound imaging (OR 0.34, 0.21 to 0.57; P < 0.001). Female sex and preoperative ultrasonography, but not age, were significantly associated with normal appendicectomy in general surgery units but not in paediatric surgery units in this adjusted model. The unadjusted 30-day adverse event rate was higher in paediatric surgery units than in general surgery units (OR 1.90, 1.18 to 3.06; P = 0.011). When adjusted for case mix and consultant presence at surgery, no statistically significant relationship between centre type and 30-day adverse event rate existed (OR 1.59, 0.93 to 2.73; P = 0.091). The NAR in general surgery units was over twice that in paediatric surgery units. Despite a more severe case mix, paediatric surgery units had a

  4. Pathophysiological mechanisms of high-intensity focused ultrasound-mediated vascular occlusion and relevance to non-invasive fetal surgery

    PubMed Central

    Shaw, C. J.; ter Haar, G. R.; Rivens, I. H.; Giussani, D. A.; Lees, C. C.

    2014-01-01

    High-intensity focused ultrasound (HIFU) is a non-invasive technology, which can be used occlude blood vessels in the body. Both the theory underlying and practical process of blood vessel occlusion are still under development and relatively sparse in vivo experimental and therapeutic data exist. HIFU would however provide an alternative to surgery, particularly in circumstances where serious complications inherent to surgery outweigh the potential benefits. Accordingly, the HIFU technique would be of particular utility for fetal and placental interventions, where open or endoscopic surgery is fraught with difficulty and likelihood of complications including premature delivery. This assumes that HIFU could be shown to safely and effectively occlude blood vessels in utero. To understand these mechanisms more fully, we present a review of relevant cross-specialty literature on the topic of vascular HIFU and suggest an integrative mechanism taking into account clinical, physical and engineering considerations through which HIFU may produce vascular occlusion. This model may aid in the design of HIFU protocols to further develop this area, and might be adapted to provide a non-invasive therapy for conditions in fetal medicine where vascular occlusion is beneficial. PMID:24671935

  5. Methodology on quantification of sonication duration for safe application of MR guided focused ultrasound for liver tumour ablation.

    PubMed

    Mihcin, Senay; Karakitsios, Ioannis; Le, Nhan; Strehlow, Jan; Demedts, Daniel; Schwenke, Michael; Haase, Sabrina; Preusser, Tobias; Melzer, Andreas

    2017-12-01

    Magnetic Resonance Guided Focused Ultrasound (MRgFUS) for liver tumour ablation is a challenging task due to motion caused by breathing and occlusion due the ribcage between the transducer and the tumour. To overcome these challenges, a novel system for liver tumour ablation during free breathing has been designed. The novel TRANS-FUSIMO Treatment System (TTS, EUFP7) interacts with a Magnetic Resonance (MR) scanner and a focused ultrasound transducer to sonicate to a moving target in liver. To meet the requirements of ISO 13485; a quality management system for medical device design, the system needs to be tested for certain process parameters. The duration of sonication and, the delay after the sonication button is activated, are among the parameters that need to be quantified for efficient and safe ablation of tumour tissue. A novel methodology is developed to quantify these process parameters. A computerised scope is programmed in LabVIEW to collect data via hydrophone; where the coordinates of fiber-optic sensor assembly was fed into the TRANS-FUSIMO treatment software via Magnetic Resonance Imaging (MRI) to sonicate to the tip of the sensor, which is synchronised with the clock of the scope, embedded in a degassed water tank via sensor assembly holder. The sonications were executed for 50 W, 100 W, 150 W for 10 s to quantify the actual sonication duration and the delay after the emergency stop by two independent operators for thirty times. The deviation of the system from the predefined specs was calculated. Student's-T test was used to investigate the user dependency. The duration of sonication and the delay after the sonication were quantified successfully with the developed method. TTS can sonicate with a maximum deviation of 0.16 s (Std 0.32) from the planned duration and with a delay of 14 ms (Std 0.14) for the emergency stop. Student's T tests indicate that the results do not depend on operators (p > .05). The evidence obtained via this

  6. Image-Guided Surgery of Primary Breast Cancer Using Ultrasound Phased Arrays

    DTIC Science & Technology

    2005-07-01

    dual-mode array is ing high-intensity focused ultrasound ( HIFU ) exhibit non- is used), perhaps a result of rectified diffusion. linear behavior that...applications using high-intensity focused ultrasound ( HIFU ). We tems. Once the real-time imaging capability is available for have shown that this dual-mode...INTRODUCTION two effects lead to echo time-shift that can be estimated High intensity focused ultrasound ( HIFU ) is a and have been shown to be related local

  7. Inguinal Hernia in Athletes: Role of Dynamic Ultrasound.

    PubMed

    Vasileff, William Kelton; Nekhline, Mikhail; Kolowich, Patricia A; Talpos, Gary B; Eyler, Willam R; van Holsbeeck, Marnix

    Inguinal hernia is a commonly encountered cause of pain in athletes. Because of the anatomic complexity, lack of standard imaging, and the dynamic condition, there is no unified opinion explaining its underlying pathology. Athletes with persistent groin pain would have a high prevalence of inguinal hernia with dynamic ultrasound, and herniorrhaphy would successfully return athletes to activity. Case-control study. Level 3. Forty-seven amateur and professional athletes with sports-related groin pain who underwent ultrasound were selected based on history and examination. Patients with prior groin surgery or hip pathology were excluded. Clinical and surgical documentation were correlated with imaging. The study group was compared with 41 age-matched asymptomatic athletes. Ultrasound was positive for hernia with movement of bowel, bladder, or omental tissue anterior to the inferior epigastric vessels during Valsalva maneuver. The 47-patient symptomatic study group included 41 patients with direct inguinal hernias, 1 with indirect inguinal hernia, and 5 with negative ultrasound. Of 42 patients with hernia, 39 significantly improved with herniorrhaphy, 2 failed to improve after surgery and were diagnosed with adductor longus tears, and 1 improved with physical therapy. Five patients with negative ultrasound underwent magnetic resonance imaging and were diagnosed with hip labral tear or osteitis pubis. The 41-patient asymptomatic control group included 3 patients with direct inguinal hernias, 2 with indirect inguinal hernias, and 3 with femoral hernias. Inguinal hernias are a major component of groin pain in athletes. Prevalence of direct inguinal hernia in symptomatic athletes was greater than that for controls ( P < 0.001). Surgery was successful in returning these athletes to sport: 39 of 42 (93%) athletes with groin pain and inguinal hernia became asymptomatic. Persistent groin pain in the athlete may relate to inguinal hernia, which can be diagnosed with dynamic

  8. Ultrasound biomicroscopic findings in hallerman-streiff syndrome.

    PubMed

    Sato, Miho; Terasaki, Hiroko; Amano, Emil; Okamoto, Yoko; Miyake, Yozo

    2002-01-01

    To demonstrate the usefulness of ultrasound biomicroscopy in detecting the morphological changes in the lens caused by the spontaneous absorption of lens material and to detect fundus abnormalities in a patient with Hallermann-Streiff syndrome. Case report of an infant diagnosed at the age of 2 months as having Hallermann-Streiff syndrome. Spontaneous lens absorption occurred during the course of follow-up and was detected only by ultrasound biomicroscopy after the patient was prepared for cataract surgery. The changes in the anterior chamber depth and lens shapes were documented by ultrasound biomicroscopy. Retinal folds that were barely observable by conventional ophthalmoscopy because of a dense cataract were clearly shown by ultrasound biomicroscopy. Ultrasound biomicroscopy can be used to examine the lenses of eyes that are not observable with conventional optical instruments. Ultrasound biomicroscopy can also be used to study the posterior segment of microphthalmic eyes. We recommend preoperative ultrasound biomicroscopy to prevent unnecessary anesthesia and surgical preparation.

  9. [Neuroprotective subthalamotomy in Parkinson's disease. The role of magnetic resonance-guided focused ultrasound in early surgery].

    PubMed

    Guridi, Jorge; Marigil, Miguel; Becerra, Victoria; Parras, Olga

    Subthalamic nucleus hyperactivity in Parkinson's disease may be a very early phenomenon. Its start is not well known, and it may occur during the pre-symptomatic disease stage. Glutamatergic hyperactivity may be neurotoxic over the substantia nigra compacta dopaminergic neurons. If this occurred, the excitatory neurotransmitter, glutamate, should affect the neurons that maintain a high turnover as a compensatory mechanism. Would a subthalamic nucleus lesion decrease this hyperactivity and thus be considered as a neuroprotective mechanism for dopaminergic neurons? The authors hypothesise about the possibility to perform surgery on a subthalamic nucleus lesion at a very early stage in order to avoid the neurotoxic glutamatergic effect over the dopaminergic neurons, and therefore be considered as a neuroprotective surgery able to alter the progress of the disease during early motor symptoms. In this regard, magnetic resonance-guided focused ultrasound techniques open a new window in the stereotactic armamentarium. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Intra-operative ultrasound-based augmented reality guidance for laparoscopic surgery.

    PubMed

    Singla, Rohit; Edgcumbe, Philip; Pratt, Philip; Nguan, Christopher; Rohling, Robert

    2017-10-01

    In laparoscopic surgery, the surgeon must operate with a limited field of view and reduced depth perception. This makes spatial understanding of critical structures difficult, such as an endophytic tumour in a partial nephrectomy. Such tumours yield a high complication rate of 47%, and excising them increases the risk of cutting into the kidney's collecting system. To overcome these challenges, an augmented reality guidance system is proposed. Using intra-operative ultrasound, a single navigation aid, and surgical instrument tracking, four augmentations of guidance information are provided during tumour excision. Qualitative and quantitative system benefits are measured in simulated robot-assisted partial nephrectomies. Robot-to-camera calibration achieved a total registration error of 1.0 ± 0.4 mm while the total system error is 2.5 ± 0.5 mm. The system significantly reduced healthy tissue excised from an average (±standard deviation) of 30.6 ± 5.5 to 17.5 ± 2.4 cm 3 ( p < 0.05) and reduced the depth from the tumor underside to cut from an average (±standard deviation) of 10.2 ± 4.1 to 3.3 ± 2.3 mm ( p < 0.05). Further evaluation is required in vivo, but the system has promising potential to reduce the amount of healthy parenchymal tissue excised.

  11. Controlling cavitation-based image contrast in focused ultrasound histotripsy surgery.

    PubMed

    Allen, Steven P; Hall, Timothy L; Cain, Charles A; Hernandez-Garcia, Luis

    2015-01-01

    To develop MRI feedback for cavitation-based, focused ultrasound, tissue erosion surgery (histotripsy), we investigate image contrast generated by transient cavitation events. Changes in GRE image intensity are observed while balanced pairs of field gradients are varied in the presence of an acoustically driven cavitation event. The amplitude of the acoustic pulse and the timing between a cavitation event and the start of these gradient waveforms are also varied. The magnitudes and phases of the cavitation site are compared with those of control images. An echo-planar sequence is used to evaluate histotripsy lesions in ex vivo tissue. Cavitation events in water cause localized attenuation when acoustic pulses exceed a pressure threshold. Attenuation increases with increasing gradient amplitude and gradient lobe separation times and is isotropic with gradient direction. This attenuation also depends upon the relative timing between the cavitation event and the start of the balanced gradients. These factors can be used to control the appearance of attenuation while imaging ex vivo tissue. By controlling the timing between cavitation events and the imaging gradients, MR images can be made alternately sensitive or insensitive to cavitation. During therapy, these images can be used to isolate contrast generated by cavitation. © 2014 Wiley Periodicals, Inc.

  12. The use of ultrasound in the diagnosis of abdominal wall hernias.

    PubMed

    Young, J; Gilbert, A I; Graham, M F

    2007-08-01

    The diagnosis of abdominal wall hernias is not always straightforward and may require additional investigative modalities. Real-time ultrasound is accurate, non-invasive, relatively inexpensive, and readily available. The value of ultrasound as an adjunctive tool in the diagnosis of abdominal wall hernias in both pre-operative and post-operative patients was studied. Retrospective analysis of 200 patients treated at the Hernia Institute of Florida was carried out. In these cases, ultrasound had been used to assist with case management. Patients without previous hernia surgery and those with early and late post-herniorrhaphy complaints were studied. Patients with obvious hernias were excluded. Indications for ultrasound examination included patients with abdominal pain without a palpable hernia, a palpable mass of questionable etiology, and patients with inordinate pain or excessive swelling during the early post-operative period. Patients were treated with surgery or conservative therapy depending on the results of the physical examination and ultrasound studies. Cases in which the ultrasound findings influenced the decision-making process by confirming clinical findings or altering the diagnosis and changing the treatment plan are discussed. Of the 200 patients, 144 complained of pain alone and on physical exam no hernia or mass was palpable. Of these 144 patients with pain alone, 21 had a hernia identified on the US examination and were referred for surgery. The 108 that had a negative ultrasound were treated conservatively with rest, heat, and anti-inflammatory drugs, most often with excellent results. Of the 56 remaining patients who had a mass, with or without pain, 22 had hernias identified by means of ultrasound examination. In the other 34, the etiology of the mass was not a hernia. Abdominal wall ultrasound is a valuable tool in the scheme of management of patients in whom the diagnosis of abdominal wall hernia is unclear. Therapeutic decisions can be

  13. Motion compensation with skin contact control for high intensity focused ultrasound surgery in moving organs

    NASA Astrophysics Data System (ADS)

    Diodato, A.; Cafarelli, A.; Schiappacasse, A.; Tognarelli, S.; Ciuti, G.; Menciassi, A.

    2018-02-01

    High intensity focused ultrasound (HIFU) is an emerging therapeutic solution that enables non-invasive treatment of several pathologies, mainly in oncology. On the other hand, accurate targeting of moving abdominal organs (e.g. liver, kidney, pancreas) is still an open challenge. This paper proposes a novel method to compensate the physiological respiratory motion of organs during HIFU procedures, by exploiting a robotic platform for ultrasound-guided HIFU surgery provided with a therapeutic annular phased array transducer. The proposed method enables us to keep the same contact point between the transducer and the patient’s skin during the whole procedure, thus minimizing the modification of the acoustic window during the breathing phases. The motion of the target point is compensated through the rotation of the transducer around a virtual pivot point, while the focal depth is continuously adjusted thanks to the axial electronically steering capabilities of the HIFU transducer. The feasibility of the angular motion compensation strategy has been demonstrated in a simulated respiratory-induced organ motion environment. Based on the experimental results, the proposed method appears to be significantly accurate (i.e. the maximum compensation error is always under 1 mm), thus paving the way for the potential use of this technique for in vivo treatment of moving organs, and therefore enabling a wide use of HIFU in clinics.

  14. Ultrasound-assisted endoscopic partial plantar fascia release.

    PubMed

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  15. Ultrasound-Assisted Endoscopic Partial Plantar Fascia Release

    PubMed Central

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure. PMID:24265989

  16. Reproducibility of Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Thermal Lesions in Minimally-Invasive Brain Surgery

    NASA Astrophysics Data System (ADS)

    Zahedi, Sulmaz

    This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.

  17. Comparison of Ultrasound with Peripheral Nerve Stimulator-guided Technique for Supraclavicular Block in Upper Limb Surgeries: A Randomized Controlled Trial.

    PubMed

    Alfred, Vinu Mervick; Srinivasan, Gnanasekaran; Zachariah, Mamie

    2018-01-01

    The supraclavicular approach is considered to be the easiest and most effective approach to block the brachial plexus for upper limb surgeries. The classical approach using the anatomical landmark technique was associated with higher failure rates and complications. Ultrasonography (USG) guidance and peripheral nerve stimulator (PNS) have improved the success rates and safety margin. The aim of the present study is to compare USG with PNS in supraclavicular brachial plexus block for upper limb surgeries with respect to the onset of motor and sensory blockade, total duration of blockade, procedure time, and complications. Prospective, randomized controlled study. Sixty patients aged above 18 years scheduled for elective upper limb surgery were randomly allocated into two groups. Group A patients received supraclavicular brachial plexus block under ultrasound guidance and in Group B patients, PNS was used. In both groups, local anesthetic mixture consisting of 15 ml of 0.5% bupivacaine and 10 ml of 2% lignocaine with 1:200,000 adrenaline were used. Independent t -test used to compare mean between groups; Chi-square test for categorical variables. The procedure time was shorter with USG (11.57 ± 2.75 min) compared to PNS (21.73 ± 4.84). The onset time of sensory block (12.83 ± 3.64 min vs. 16 ± 3.57 min) and onset of motor block (23 ± 4.27 min vs. 27 ± 3.85 min) were significantly shorter in Group A compared to Group B ( P < 0.05). The duration of sensory block was significantly prolonged in Group A (8.00 ± 0.891 h) compared to Group B (7.25 ± 1.418 h). None of the patients in either groups developed any complications. The ultrasound-guided supraclavicular brachial plexus block can be done quicker, with a faster onset of sensory and motor block compared to nerve stimulator technique.

  18. Ultrasound assessment of gastric volume in children after drinking carbohydrate-containing fluids.

    PubMed

    Song, I-K; Kim, H-J; Lee, J-H; Kim, E-H; Kim, J-T; Kim, H-S

    2016-04-01

    Gastric ultrasound is a valid tool for non-invasive assessment of the nature and volume of gastric contents in adults and children. Perioperative fasting guidelines recommend oral carbohydrates up to 2 h before elective surgery. We evaluated gastric volume in children using ultrasound before and after drinking carbohydrate fluids before surgery. Paediatric patients younger than 18 yr old undergoing elective surgery were enrolled. Initial ultrasound assessment of gastric volume was performed after fasting for 8 h. Two hours before surgery, patients were given carbohydrate drinks: 15 ml kg(-1) for patients younger than 3 yr old and 10 ml kg(-1) for those more than 3 yr old. Before induction of general anaesthesia, the gastric volume was reassessed. Parental satisfaction scores (0=totally satisfied, 10=totally dissatisfied) and complications were recorded. Of the 86 enrolled patients, 79 completed the study; three refused to ingest the requested volume, and surgery was delayed for more than 2 h in four patients. The mean (sd) of the initial and second ultrasound measurements were 2.09 (0.97) and 1.85 (0.94) cm(2), respectively (P=0.01; mean difference 0.24 cm(2), 95% confidence interval 0.06-0.43). The median (interquartile range) satisfaction score was 2.4 (0-6). Two instances of postoperative vomiting and one instance of postoperative nausea occurred. Carbohydrate fluids ingested 2 h before surgery reduced the gastric volume and did not cause serious complications in paediatric patients. Parents were satisfied with the preoperative carbohydrate drink. Children may benefit from drinking carbohydrate fluids up to 2 h before elective surgery. cris.nih.go.kr (KCT0001546). © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Active point out-of-plane ultrasound calibration

    NASA Astrophysics Data System (ADS)

    Cheng, Alexis; Guo, Xiaoyu; Zhang, Haichong K.; Kang, Hyunjae; Etienne-Cummings, Ralph; Boctor, Emad M.

    2015-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common intraoperative medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the transducer and the ultrasound image. Point-based phantoms are considered to be accurate, but their calibration framework assumes that the point is in the image plane. In this work, we present the use of an active point phantom and a calibration framework that accounts for the elevational uncertainty of the point. Given the lateral and axial position of the point in the ultrasound image, we approximate a circle in the axial-elevational plane with a radius equal to the axial position. The standard approach transforms all of the imaged points to be a single physical point. In our approach, we minimize the distances between the circular subsets of each image, with them ideally intersecting at a single point. We simulated in noiseless and noisy cases, presenting results on out-of-plane estimation errors, calibration estimation errors, and point reconstruction precision. We also performed an experiment using a robot arm as the tracker, resulting in a point reconstruction precision of 0.64mm.

  20. A comparison of ultrasound-guided interscalene and supraclavicular blocks for post-operative analgesia after shoulder surgery.

    PubMed

    Kim, B G; Han, J U; Song, J H; Yang, C; Lee, B W; Baek, J S

    2017-04-01

    In contrast to interscalene block, there was little information regarding the analgesic efficacy of supraclavicular block for shoulder surgery. This study aimed to compare the analgesic efficacy and side effects of interscalene and supraclavicular blocks for shoulder surgery. Patients scheduled for shoulder surgery were assigned to receive either ultrasound-guided interscalene (n = 25) or supraclavicular block (n = 24) with 20 ml of 0.375% ropivacaine. We assessed the duration of post-operative analgesia as a primary outcome and pain scores, supplemental analgesia, diaphragmatic excursion, motor block, fingertip numbness, side effects, and patient satisfaction as secondary outcomes. The duration of post-operative analgesia was not statistically different between groups: 868 (800-1440) min for supraclavicular block vs. 800 (731-922) min for interscalene block (median difference -85 min, 95% CI, -283 to 3 min, P = 0.095). The incidence of diaphragmatic paresis was significantly lower in the supraclavicular block group compared with that in the interscalene block group, both at 30 min after the block (66.7% vs. 92%, P = 0.021) and in the post-anaesthesia care unit (62.5% vs. 92%, P = 0.024). Motor block was higher in the supraclavicular block group in the post-anaesthesia care unit, however, not at 24 h. Other secondary outcomes were similar for both groups. This study showed no statistically significant difference in the duration of post-operative analgesia between the supraclavicular and interscalene blocks. However, the supraclavicular block was associated with a lower incidence of diaphragmatic paresis compared with that of the interscalene block after shoulder surgery. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. Cost-effectiveness of uterine-preserving procedures for the treatment of uterine fibroid symptoms in the USA.

    PubMed

    Cain-Nielsen, Anne H; Moriarty, James P; Stewart, Elizabeth A; Borah, Bijan J

    2014-09-01

    To evaluate the cost-effectiveness of the following three treatments of uterine fibroids in a population of premenopausal women who wish to preserve their uteri: myomectomy, magnetic resonance-guided focused ultrasound (MRgFUS) and uterine artery embolization (UAE). A decision analytic Markov model was constructed. Cost-effectiveness was calculated in terms of US$ per quality-adjusted life year (QALY) over 5 years. Two types of costs were calculated: direct costs only, and the sum of direct and indirect (productivity) costs. Women in the hypothetical cohort were assessed for treatment type eligibility, were treated based on eligibility, and experienced adequate or inadequate symptom relief. Additional treatment (myomectomy) occurred for inadequate symptom relief or recurrence. Sensitivity analysis was conducted to evaluate uncertainty in the model parameters.  In the base case, myomectomy, MRgFUS and UAE had the following combinations of mean cost and mean QALYs, respectively: US$15,459, 3.957; US$15,274, 3.953; and US$18,653, 3.943. When incorporating productivity costs, MRgFUS incurred a mean cost of US$21,232; myomectomy US$22,599; and UAE US$22,819. Using probabilistic sensitivity analysis (PSA) and excluding productivity costs, myomectomy was cost effective at almost every decision threshold. Using PSA and incorporating productivity costs, myomectomy was cost effective at decision thresholds above US$105,000/QALY; MRgFUS was cost effective between US$30,000 and US$105,000/QALY; and UAE was cost effective below US$30,000/QALY. Myomectomy, MRgFUS, and UAE were similarly effective in terms of QALYs gained. Depending on assumptions about costs and willingness to pay for additional QALYs, all three treatments can be deemed cost effective in a 5-year time frame.

  2. Localization of liver tumors in freehand 3D laparoscopic ultrasound

    NASA Astrophysics Data System (ADS)

    Shahin, O.; Martens, V.; Besirevic, A.; Kleemann, M.; Schlaefer, A.

    2012-02-01

    The aim of minimally invasive laparoscopic liver interventions is to completely resect or ablate tumors while minimizing the trauma caused by the operation. However, restrictions such as limited field of view and reduced depth perception can hinder the surgeon's capabilities to precisely localize the tumor. Typically, preoperative data is acquired to find the tumor(s) and plan the surgery. Nevertheless, determining the precise position of the tumor is required, not only before but also during the operation. The standard use of ultrasound in hepatic surgery is to explore the liver and identify tumors. Meanwhile, the surgeon mentally builds a 3D context to localize tumors. This work aims to upgrade the use of ultrasound in laparoscopic liver surgery. We propose an approach to segment and localize tumors intra-operatively in 3D ultrasound. We reconstruct a 3D laparoscopic ultrasound volume containing a tumor. The 3D image is then preprocessed and semi-automatically segmented using a level set algorithm. During the surgery, for each subsequent reconstructed volume, a fast update of the tumor position is accomplished via registration using the previously segmented and localized tumor as a prior knowledge. The approach was tested on a liver phantom with artificial tumors. The tumors were localized in approximately two seconds with a mean error of less than 0.5 mm. The strengths of this technique are that it can be performed intra-operatively, it helps the surgeon to accurately determine the location, shape and volume of the tumor, and it is repeatable throughout the operation.

  3. Comparison of Paravertebral Block by Anatomic Landmark Technique to Ultrasound-Guided Paravertebral Block for Breast Surgery Anesthesia: A Randomized Controlled Trial.

    PubMed

    Patnaik, Rupali; Chhabra, Anjolie; Subramaniam, Rajeshwari; Arora, Mahesh K; Goswami, Devalina; Srivastava, Anurag; Seenu, Vuthaluru; Dhar, Anita

    2018-05-01

    Paravertebral block (PVB) is an established technique for providing anesthesia for breast surgery. The primary objective was to compare anatomical landmark technique (ALT) to the ultrasound-guided (USG) PVB block for providing surgical anesthesia. Secondary objectives included comparison of perioperative analgesia and complications. This randomized, controlled, observer-blinded study included 72 females, aged 18 to 65 years, American Society of Anesthesiologists physical status I or II, undergoing elective unilateral breast surgery. Study participants were randomized to the ALT group or USG group. Ipsilateral PVB was performed with the respective technique from T1 to T6. Five milliliters of local anesthetic mixture (0.5% ropivacaine, 5 μg/mL adrenaline, 1 μg/kg clonidine) was administered at each level. Paravertebral catheter was inserted at T4/T3 level. After confirming sensory loss, patients were taken up for surgery with propofol sedation (20-50 μg/kg per minute). More patients in the USG group (34/36 [94.44%]) had a successful block as compared with the ALT group (26/36 [72.22%]) (P = 0.024). Difference in proportion was 18.1 (95% confidence interval, 0.15-36.0) (P = 0.024) after adjustment for age. More dermatomes were blocked in the USG group (P = 0.0018) with less sparing of upper T2 and T3 dermatomes (P = 0.003, P = 0.006, respectively). Median time to first postoperative analgesic requirement was 502.5 minutes (range, 195-1440 minutes) in the USG group versus 377.5 minutes (range, 215-1440 minutes) in the ALT group. Pain at rest and movement 2 and 4 hours postoperatively and number of catheter top-ups in 24 hours postoperatively were lesser in the USG group (P = 0.012). Complications were comparable. Ultrasound-guided PVB provided better anesthesia and perioperative analgesia than the landmark technique for breast surgery. The trial was registered retrospectively at the Clinical Trial Registry of India, CTRI/2015/05/005774.

  4. Fast Track ultrasound protocol to detect acute complications after totally implantable venous access device placement.

    PubMed

    Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng

    2015-01-01

    The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.

  5. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  6. System for robot-assisted real-time laparoscopic ultrasound elastography

    NASA Astrophysics Data System (ADS)

    Billings, Seth; Deshmukh, Nishikant; Kang, Hyun Jae; Taylor, Russell; Boctor, Emad M.

    2012-02-01

    Surgical robots provide many advantages for surgery, including minimal invasiveness, precise motion, high dexterity, and crisp stereovision. One limitation of current robotic procedures, compared to open surgery, is the loss of haptic information for such purposes as palpation, which can be very important in minimally invasive tumor resection. Numerous studies have reported the use of real-time ultrasound elastography, in conjunction with conventional B-mode ultrasound, to differentiate malignant from benign lesions. Several groups (including our own) have reported integration of ultrasound with the da Vinci robot, and ultrasound elastography is a very promising image guidance method for robotassisted procedures that will further enable the role of robots in interventions where precise knowledge of sub-surface anatomical features is crucial. We present a novel robot-assisted real-time ultrasound elastography system for minimally invasive robot-assisted interventions. Our system combines a da Vinci surgical robot with a non-clinical experimental software interface, a robotically articulated laparoscopic ultrasound probe, and our GPU-based elastography system. Elasticity and B-mode ultrasound images are displayed as picture-in-picture overlays in the da Vinci console. Our system minimizes dependence on human performance factors by incorporating computer-assisted motion control that automatically generates the tissue palpation required for elastography imaging, while leaving high-level control in the hands of the user. In addition to ensuring consistent strain imaging, the elastography assistance mode avoids the cognitive burden of tedious manual palpation. Preliminary tests of the system with an elasticity phantom demonstrate the ability to differentiate simulated lesions of varied stiffness and to clearly delineate lesion boundaries.

  7. Design and development of an ultrasound calibration phantom and system

    NASA Astrophysics Data System (ADS)

    Cheng, Alexis; Ackerman, Martin K.; Chirikjian, Gregory S.; Boctor, Emad M.

    2014-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the ultrasound transducer and the ultrasound image. A phantom or model with known geometry is also required. In this work, we design and test an ultrasound calibration phantom and software. The two main considerations in this work are utilizing our knowledge of ultrasound physics to design the phantom and delivering an easy to use calibration process to the user. We explore the use of a three-dimensional printer to create the phantom in its entirety without need for user assembly. We have also developed software to automatically segment the three-dimensional printed rods from the ultrasound image by leveraging knowledge about the shape and scale of the phantom. In this work, we present preliminary results from using this phantom to perform ultrasound calibration. To test the efficacy of our method, we match the projection of the points segmented from the image to the known model and calculate a sum squared difference between each point for several combinations of motion generation and filtering methods. The best performing combination of motion and filtering techniques had an error of 1.56 mm and a standard deviation of 1.02 mm.

  8. An ex vivo feasibility experimental study on targeted cell surgery by high intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Wang, Zhi Biao; Wu, Junru; Fang, Liao Qiong; Wang, Hua; Li, Fa Qi; Tian, Yun Bo; Gong, Xiao Bo; Zhang, Hong; Zhang, Lian; Feng, Ruo

    2012-10-01

    High intensity focused ultrasound (HIFU) has become a new noninvasive surgical modality in medicine. A portion of tissue seated inside a patient's body may experience coagulative necrosis after a few seconds of insonification by high intensity focused ultrasound (US) generated by an extracorporeal focusing US transducer. The region of tissue affected by coagulative necrosis (CN) usually has an ellipsoidal shape when the thermal effect due to US absorption plays the dominant role. Its long and short axes are parallel and perpendicular to the US propagation direction respectively. It was shown by ex vivo experiments that the dimension of the short and long axes of the tissue which experiences CN can be as small as 50 μm and 250 μm respectively after one second exposure of US pulse (the spatial and pulse average acoustic power is on the order of tens of Watts and the local acoustic spatial and temporal pulse averaged intensity is on the order of 3 × 104 W/cm2) generated by a 1.6 MHz HIFU transducer of 12 cm diameter and 11 cm geometric focal length (f-number = 0.92). The numbers of cells which suffered CN were estimated to be on the order of 40. This result suggests that HIFU is able to interact with tens of cells at/near its focal zone while keeping the neighboring cells minimally affected, and thus the targeted cell surgery may be achievable.

  9. Renal ultrasound provides low utility in evaluating cardiac surgery associated acute kidney injury.

    PubMed

    Young, Allen; Crawford, Todd; Pierre, Alejandro Suarez; Trent Magruder, J; Fraser, Charles; Conte, John; Whitman, Glenn; Sciortino, Christopher

    2017-09-02

    Renal ultrasonography is part of the algorithm in assessing acute kidney injury (AKI). The purpose of this study was to assess the clinical utility of renal US in postoperative cardiac patients who develop AKI. We conducted a retrospective study of 90 postoperative cardiac surgery patients at a single institution from 1/19/2010 to 3/19/2016 who underwent renal US for AKI. We reviewed provider documentation to determine whether renal US changed management. We defined change as: administration of crystalloid or colloid, addition of inotropic or vasopressor, or procedural interventions on the renal system. Mean age of study patients was 68 ± 13 years. 48/90 patients (53.3%) had pre-existing chronic kidney disease of varying severity. 48 patients (53.3%) had normal renal US with incidental findings and 31 patients (34.4%) had US evidence of medical kidney disease. 10 patients (11.1%) had limited US results due to poor visualization and 1 patient (1.1%) had mild right-sided hydronephrosis. No patients were found to have obstructive uropathy or renal artery stenosis. Clinical management was altered in only 4/90 patients (4.4%), which included 3 patients that received a fluid bolus and 1 patient that received a fluid bolus and inotropes. No vascular or urologic procedures resulted from US findings. Although renal ultrasound is often utilized in the work-up of AKI, our study shows that renal US provides little benefit in managing postoperative cardiac patients. This diagnostic modality should be scrutinized rather than viewed as a universal measure in the cardiac surgery population.

  10. Smith predictor-based robot control for ultrasound-guided teleoperated beating-heart surgery.

    PubMed

    Bowthorpe, Meaghan; Tavakoli, Mahdi; Becher, Harald; Howe, Robert

    2014-01-01

    Performing surgery on fast-moving heart structures while the heart is freely beating is next to impossible. Nevertheless, the ability to do this would greatly benefit patients. By controlling a teleoperated robot to continuously follow the heart's motion, the heart can be made to appear stationary. The surgeon will then be able to operate on a seemingly stationary heart when in reality it is freely beating. The heart's motion is measured from ultrasound images and thus involves a non-negligible delay due to image acquisition and processing, estimated to be 150 ms that, if not compensated for, can cause the teleoperated robot's end-effector (i.e., the surgical tool) to collide with and puncture the heart. This research proposes the use of a Smith predictor to compensate for this time delay in calculating the reference position for the teleoperated robot. The results suggest that heart motion tracking is improved as the introduction of the Smith predictor significantly decreases the mean absolute error, which is the error in making the distance between the robot's end-effector and the heart follow the surgeon's motion, and the mean integrated square error.

  11. Ultrasound imaging of the thenar motor branch of the median nerve: a cadaveric study.

    PubMed

    Petrover, David; Bellity, Jonathan; Vigan, Marie; Nizard, Remy; Hakime, Antoine

    2017-11-01

    Anatomic variations of the median nerve (MN) increase the risk of iatrogenic injury during carpal tunnel release surgery. We investigated whether high-frequency ultrasonography could identify anatomic variations of the MN and its thenar motor branch (MBMN) in the carpal tunnel. For each volar wrist of healthy non-embalmed cadavers, the type of MN variant (Lanz classification), course and orientation of the MBMN, and presence of hypertrophic muscles were scored by 18-MHz ultrasound and then by dissection. MBMN was identified by ultrasound in all 30 wrists (15 subjects). By dissection, type 1, 2 and 3 variants were found in 84%, 3%, and 13% of wrists, respectively. Ultrasound had good agreement with dissection in identifying the variant type (kappa =0.9). With both techniques, extra-, sub-, and transligamentous courses were recorded in 65%, 31%, and 4% of cases, respectively. With both techniques, the bifid nerve, hypertrophic muscles, and bilateral symmetry for variant type were identified in 13.3%, 13.3%, and 86.7% of wrists, respectively. Agreement between ultrasound and dissection was excellent for the MBMN course and orientation (kappa =1). Ultrasound can be used reliably to identify anatomic variations of the MN and MBMN. It could be a useful tool before carpal tunnel release surgery. • Ultrasound can identify variations of the motor branch of the median nerve. • Ultrasound mapping should be used prior to carpal tunnel release surgery. • All sub-, extra-, and transligamentous courses were accurately identified. • Type 3 variants (bifid nerve), hypertrophic muscles, and bilateral symmetry were accurately identified.

  12. Optimized Hyperthermia Treatment of Prostate Cancer Using a Novel Intracavitary Ultrasound Array

    DTIC Science & Technology

    2005-01-01

    many problems Introduction involved with transducer fabrication. Focused ultrasound surgery ( FUS ) has been shown to give promising results in treating...low frequencies are used) (Hutchinson 1997). With focused ultrasound ( FUS ), tissue is noninvasively necrosed by elevating the temperature at the focal...curved 1.5 dimensional (1.5-D) array that could, but had of a 1.75 dimensional (1.75-D) tapered ultrasound phased array restrictions to the focusing

  13. Does intravenous ketamine enhance analgesia after arthroscopic shoulder surgery with ultrasound guided single-injection interscalene block?: a randomized, prospective, double-blind trial.

    PubMed

    Woo, Jae Hee; Kim, Youn Jin; Baik, Hee Jung; Han, Jong In; Chung, Rack Kyung

    2014-07-01

    Ketamine has anti-inflammatory, analgesic and antihyperalgesic effect and prevents pain associated with wind-up. We investigated whether low doses of ketamine infusion during general anesthesia combined with single-shot interscalene nerve block (SSISB) would potentiate analgesic effect of SSISB. Forty adult patients scheduled for elective arthroscopic shoulder surgery were enrolled and randomized to either the control group or the ketamine group. All patients underwent SSISB and followed by general anesthesia. During an operation, intravenous ketamine was infused to the patients of ketamine group continuously. In control group, patients received normal saline in volumes equivalent to ketamine infusions. Pain score by numeric rating scale was similar between groups at 1, 6, 12, 24, 36, and 48 hr following surgery, which was maintained lower than 3 in both groups. The time to first analgesic request after admission on post-anesthesia care unit was also not significantly different between groups. Intraoperative low dose ketamine did not decrease acute postoperative pain after arthroscopic shoulder surgery with a preincisional ultrasound guided SSISB. The preventive analgesic effect of ketamine could be mitigated by SSISB, which remains one of the most effective methods of pain relief after arthroscopic shoulder surgery.

  14. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    NASA Astrophysics Data System (ADS)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  15. Three-dimensional intraoperative ultrasound of vascular malformations and supratentorial tumors.

    PubMed

    Woydt, Michael; Horowski, Anja; Krauss, Juergen; Krone, Andreas; Soerensen, Niels; Roosen, Klaus

    2002-01-01

    The benefits and limits of a magnetic sensor-based 3-dimensional (3D) intraoperative ultrasound technique during surgery of vascular malformations and supratentorial tumors were evaluated. Twenty patients with 11 vascular malformations and 9 supratentorial tumors undergoing microsurgical resection or clipping were investigated with an interactive magnetic sensor data acquisition system allowing freehand scanning. An ultrasound probe with a mounted sensor was used after craniotomies to localize lesions, outline tumors or malformation margins, and identify supplying vessels. A 3D data set was obtained allowing reformation of multiple slices in all 3 planes and comparison to 2-dimensional (2D) intraoperative ultrasound images. Off-line gray-scale segmentation analysis allowed differentiation between tissue with different echogenicities. Color-coded information about blood flow was extracted from the images with a reconstruction algorithm. This allowed photorealistic surface displays of perfused tissue, tumor, and surrounding vessels. Three-dimensional intraoperative ultrasound data acquisition was obtained within 5 minutes. Off-line analysis and reconstruction time depends on the type of imaging display and can take up to 30 minutes. The spatial relation between aneurysm sac and surrounding vessels or the skull base could be enhanced in 3 out of 6 aneurysms with 3D intraoperative ultrasound. Perforating arteries were visible in 3 cases only by using 3D imaging. 3D ultrasound provides a promising imaging technique, offering the neurosurgeon an intraoperative spatial orientation of the lesion and its vascular relationships. Thereby, it may improve safety of surgery and understanding of 2D ultrasound images.

  16. Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation.

    PubMed

    Liu, Tianzhi; Zhang, Nan; Wang, Zhigang; Wu, Meiying; Chen, Yu; Ma, Ming; Chen, Hangrong; Shi, Jianlin

    2017-09-26

    High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H 2 O 2 , facilitating the continuous O 2 gas generation in a relatively mild manner even if incubated with 10 μM H 2 O 2 , which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H 2 O 2 -enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo. Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.

  17. Intraoperative ultrasound of the pancreas.

    PubMed

    Shin, Lewis K; Brant-Zawadzki, Graham; Kamaya, Aya; Jeffrey, R Brooke

    2009-03-01

    Intraoperative ultrasound provides spatial resolution of the pancreas superior to computed tomography, magnetic resonance imaging, and transabdominal sonography. This pictorial essay will review common benign and malignant pancreatic processes including the following: pancreatic ductal adenocarcinoma, pancreatitis, endocrine tumors, mucinous cystic neoplasm, intraductal papillary mucinous neoplasm, serous cystadenoma, and solid pseudopapillary tumor. The use of intraoperative ultrasound in specific surgical situations will be discussed, which include the following: (1) identification of insulinoma(s) which are not detectable preoperatively, (2) identification of the pancreatic duct to determine dissection planes for chronic pancreatitis surgery (eg, Puestow procedure) and for tumor resection, and (3) staging purposes for malignant disease.

  18. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large

  19. Correlation between intraoperative ultrasound and postoperative MRI in pediatric tumor surgery.

    PubMed

    Smith, Heather; Taplin, AmiLyn; Syed, Sohail; Adamo, Matthew A

    2016-11-01

    OBJECTIVE Malignant disease of the CNS is the primary etiology for deaths resulting from cancer in the pediatric population. It has been well documented that outcomes of pediatric neurosurgery rely on the extent of tumor resection. Therefore, techniques that improve surgical results have significant clinical implications. Intraoperative ultrasound (IOUS) offers real-time surgical guidance and a more accurate means for detecting residual tumor that is inconspicuous to the naked eye. The objective of this study was to evaluate the correlation of extent of resection between IOUS and postoperative MRI. The authors measured the correlation of extent of resection, negative predictive value, and sensitivity of IOUS and compared them with those of MRI. METHODS This study consisted of a retrospective review of the medical charts of all pediatric patients who underwent neurosurgical treatment of a tumor between August 2009 and July 2015 at Albany Medical Center. Included were patients who were aged ≤ 21 years, who underwent brain or spinal tumor resection, for whom IOUS was used during the tumor resection, and for whom postoperative MRI (with and without contrast) was performed within 1 week of surgery. RESULTS Sixty-two patients met inclusion criteria for the study (33 males, mean age 10.0 years). The IOUS results very significantly correlated with postoperative MRI results (φ = 0.726; p = 0.000000011; negative predictive value 86.3% [95% CI 73.7%-94.3%]). These results exemplify a 71% overall gross-total resection rate and 80% intended gross-total resection rate with the use of IOUS (i.e., excluding cases performed only for debulking purposes). CONCLUSIONS The use of IOUS may play an important role in achieving a greater extent of resection by providing real-time information on tumor volume and location in the setting of brain shift throughout the course of an operation. The authors support the use of IOUS in pediatric CNS tumor surgery to improve clinical outcomes at

  20. Strain ratio ultrasound elastography increases the accuracy of colour-Doppler ultrasound in the evaluation of Thy-3 nodules. A bi-centre university experience.

    PubMed

    Cantisani, Vito; Maceroni, Piero; D'Andrea, Vito; Patrizi, Gregorio; Di Segni, Mattia; De Vito, Corrado; Grazhdani, Hektor; Isidori, Andrea M; Giannetta, Elisa; Redler, Adriano; Frattaroli, Fabrizio; Giacomelli, Laura; Di Rocco, Giorgio; Catalano, Carlo; D'Ambrosio, Ferdinando

    2016-05-01

    To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.

  1. The utility of ultrasound and magnetic resonance imaging versus surgery for the characterization of müllerian anomalies in the pediatric and adolescent population.

    PubMed

    Santos, X M; Krishnamurthy, R; Bercaw-Pratt, J L; Dietrich, J E

    2012-06-01

    To evaluate the utility of transabdominal ultrasound and magnetic resonance imaging in the evaluation of American Society for Reproductive Medicine (†)(ASRM)-classified müllerian anomalies compared to surgical findings in the pediatric and adolescent population. Retrospective chart review. Tertiary academic center. Thirty-eight patients with müllerian anomalies seen in our pediatric and adolescent gynecology clinic were identified both on the basis of ICD-9 codes and having magnetic resonance imaging at Texas Children's Hospital between 2004 and 2009. None. Correlation among transabdominal ultrasound and magnetic resonance imaging findings with surgical findings. Mean age was 12.2 (± 4.1) years. Twenty-eight patients underwent magnetic resonance imaging and required surgical intervention, and 88.5% demonstrated correlative consistency with surgical findings. Twenty-two patients underwent ultrasound, magnetic resonance imaging, and surgery, which revealed consistency among ultrasound and surgical findings (59.1%) and consistency among magnetic resonance imaging and surgical findings (90.9%). In ASRM diagnoses evaluated by magnetic resonance imaging, surgical findings correlated in 92% (Pearson 0.89). Overall, 55.2% of patients had a renal malformation. Magnetic resonance imaging is the gold standard imaging modality for müllerian anomalies and is an effective technique for noninvasive evaluation and accurate classification of the type of anomaly in the pediatric and adolescent population. Magnetic resonance imaging should be considered as an adjunct to transabdominal ultrasound to evaluate müllerian anomalies. Copyright © 2012 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  2. Remote ultrasound palpation for robotic interventions using absolute elastography.

    PubMed

    Schneider, Caitlin; Baghani, Ali; Rohling, Robert; Salcudean, Septimiu

    2012-01-01

    Although robotic surgery has addressed many of the challenges presented by minimally invasive surgery, haptic feedback and the lack of knowledge of tissue stiffness is an unsolved problem. This paper presents a system for finding the absolute elastic properties of tissue using a freehand ultrasound scanning technique, which utilizes the da Vinci Surgical robot and a custom 2D ultrasound transducer for intraoperative use. An external exciter creates shear waves in the tissue, and a local frequency estimation method computes the shear modulus. Results are reported for both phantom and in vivo models. This system can be extended to any 6 degree-of-freedom tracking method and any 2D transducer to provide real-time absolute elastic properties of tissue.

  3. Ultrasound Guided Intercostobrachial Nerve Blockade in Patients with Persistent Pain after Breast Cancer Surgery: A Pilot Study.

    PubMed

    Wijayasinghe, Nelun; Duriaud, Helle M; Kehlet, Henrik; Andersen, Kenneth Geving; Anderson, Kenneth G

    2016-02-01

    Persistent pain after breast cancer surgery (PPBCS) affects 25 - 60% of breast cancer survivors and damage to the intercostobrachial nerve (ICBN) has been implicated as the cause of this predominantly neuropathic pain. Local anesthetic blockade of the ICBN could provide clues to pathophysiological mechanisms as well as aiding diagnosis and treatment of PPBCS but has never been attempted. To assess the feasibility of ICBN blockade and assess its effects on pain and sensory function in patients with PPBCS. This prospective pilot study was performed in 2 parts: Part 1 determined the sonoanatomy of the ICBN and part 2 examined effects of the ultrasound-guided ICBN blockade in patients with PPBCS. Section for Surgical Pathophysiology at Rigshospitalet, Copenhagen, Denmark. Part 1: Sixteen unoperated, pain free breast cancer patients underwent systematic ultrasonography to establish the sonoanatomy of the ICBN. Part 2: Six patients with PPBCS who had pain in the axilla and upper arm were recruited for the study. Summed pain intensity (SPI) scores and sensory function were measured before and 30 minutes after the block was administered. SPI is a combined pain score of numerical rating scale (NRS) at rest, movement, and 100kPa pressure applied to the maximum point of pain using pressure algometry (max = 30). Sensory function was measured using quantitative sensory testing, which consisted of sensory mapping, thermal thresholds, suprathreshold heat pain perception as well as heat and pressure pain thresholds. The ICBN block was performed under ultrasound guidance and 10 mL 0.5% bupivacaine was injected. The ability to perform the ICBN block and its analgesic and sensory effects. Only the second intercostal space could be seen on ultrasound which was adequate to perform the ICBN block. The mean difference in SPI was -9 NRS points (95%CI: -14.1 to -3.9), P = 0.006. All patients had pre-existing areas of hypoesthesia which decreased in size in 4/6 patients after the block. The

  4. Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

    PubMed

    Módis, László Jr; Szalai, Eszter; Flaskó, Zsuzsa; Németh, Gábor

    2016-01-01

    To study the endothelial cell morphology and corneal thickness changes after phacoemulsification by using the OZil torsional and longitudinal ultrasound techniques (Infiniti Vision System, Alcon Laboratories). Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary. 52 patients with cataract were randomly assigned to longitudinal ultrasound and torsional mode group. All surgeries were performed through a 2.2 mm clear corneal incision, the method employed being divide and conquer. The endothelial morphometry such as cell density (ECD), mean cell area, coefficient of variation of cell area, and central corneal thickness were examined with specular microscopy (EM-1000, Tomey) preoperatively and 4, 8 weeks postoperatively. ECD values decreased significantly in both surgical groups (P < .001, repeated- mesures ANOVA), the postoperative endothelial cell loss was higher in the longitudinal ultrasound mode group (3.5% and 6.5%, at 4 and 8 weeks after surgery) than in the torsional group (3.3% and 5.5%, at 4 and 8 weeks after surgery), the difference not being significant between the two groups (P = .164 and P = .479, at 4 and 8 weeks after surgery, Mann-Whitney test). There was no statistically significant difference in any of the assessed parameters between the two surgical groups (P > .05). No significant correlation was found between the endothelial cell loss and the nucleus density. Both phacoemulsification techniques were safe and effective. The torsional handpiece performs oscillatory movements and delivers less energy into the eye than the longitudinal ultrasound technique, therefore providing more favorable energy and thermal safety profile.

  5. Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification

    PubMed Central

    Módis, László Jr.; Szalai, Eszter; Flaskó, Zsuzsa; Németh, Gábor

    2016-01-01

    Purpose. To study the endothelial cell morphology and corneal thickness changes after phacoemulsification by using the OZil torsional and longitudinal ultrasound techniques (Infiniti Vision System, Alcon Laboratories). Setting. Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary. Methods. 52 patients with cataract were randomly assigned to longitudinal ultrasound and torsional mode group. All surgeries were performed through a 2.2 mm clear corneal incision, the method employed being divide and conquer. The endothelial morphometry such as cell density (ECD), mean cell area, coefficient of variation of cell area, and central corneal thickness were examined with specular microscopy (EM-1000, Tomey) preoperatively and 4, 8 weeks postoperatively. Results. ECD values decreased significantly in both surgical groups (P < .001, repeated- mesures ANOVA), the postoperative endothelial cell loss was higher in the longitudinal ultrasound mode group (3.5% and 6.5%, at 4 and 8 weeks after surgery) than in the torsional group (3.3% and 5.5%, at 4 and 8 weeks after surgery), the difference not being significant between the two groups (P = .164 and P = .479, at 4 and 8 weeks after surgery, Mann-Whitney test). There was no statistically significant difference in any of the assessed parameters between the two surgical groups (P > .05). No significant correlation was found between the endothelial cell loss and the nucleus density. Conclusions. Both phacoemulsification techniques were safe and effective. The torsional handpiece performs oscillatory movements and delivers less energy into the eye than the longitudinal ultrasound technique, therefore providing more favorable energy and thermal safety profile. PMID:29450332

  6. Optical Micromachined Ultrasound Transducers (OMUT)-- A New Approach for High Frequency Ultrasound Imaging

    NASA Astrophysics Data System (ADS)

    Tadayon, Mohammad Amin

    Piezoelectric technology is the backbone of most medical ultrasound imaging arrays, however, in scaling the technology to sizes required for high frequency operation (> 20 MHz), it encounters substantial difficulties in fabrication and signal transduction efficiency. These limitations particularly affect the design of intravascular ultrasound (IVUS) imaging probes whose operating frequency can approach 60 MHz. Optical technology has been proposed and investigated for several decades as an alternative approach for high frequency ultrasound transducers. However, to apply this promising technology in guiding clinical operations such as in interventional cardiology, brain surgery, and laparoscopic surgery further raise in the sensitivity is required. Here, in order to achieve the required sensitivity for an intravascular ultrasound imaging probe, we introduce design changes making use of alternative receiver mechanisms. First, we present an air cavity detector that makes use of a polymer membrane for increased mechanical deflection. We have also significantly raised the thin film detector sensitivity by improving its optical characteristics. This can be achieved by inducing a refractive index feature inside the Fabry-Perot resonator that simply creates a waveguide between the two mirrors. This approach eliminates the loss in energy due to diffraction in the cavity, and therefore the Q-factor is only limited by mirror loss and absorption. To demonstrate this optical improvements, a waveguide Fabry-Perot resonator has been fabricated consisting of two dielectric Bragg reflectors with a layer of photosensitive polymer between them. The measured finesse of the fabricated resonator was 692, and the Q-factor was 55000. The fabrication process of this device has been modified to fabricate an ultrasonically testable waveguide Fabry-Perot resonator. By applying this method, we have achieved a noise equivalent pressure of 178 Pa over a bandwidth of 28 MHz or 0.03 Pa/Hz1/2 which

  7. Standards of ultrasound imaging of the adrenal glands

    PubMed Central

    Jakubowski, Wiesław S.; Dobruch-Sobczak, Katarzyna; Kasperlik-Załuska, Anna A.

    2015-01-01

    Adrenal glands are paired endocrine glands located over the upper renal poles. Adrenal pathologies have various clinical presentations. They can coexist with the hyperfunction of individual cortical zones or the medulla, insufficiency of the adrenal cortex or retained normal hormonal function. The most common adrenal masses are tumors incidentally detected in imaging examinations (ultrasound, tomography, magnetic resonance imaging), referred to as incidentalomas. They include a range of histopathological entities but cortical adenomas without hormonal hyperfunction are the most common. Each abdominal ultrasound scan of a child or adult should include the assessment of the suprarenal areas. If a previously non-reported, incidental solid focal lesion exceeding 1 cm (incidentaloma) is detected in the suprarenal area, computed tomography or magnetic resonance imaging should be conducted to confirm its presence and for differentiation and the tumor functional status should be determined. Ultrasound imaging is also used to monitor adrenal incidentaloma that is not eligible for a surgery. The paper presents recommendations concerning the performance and assessment of ultrasound examinations of the adrenal glands and their pathological lesions. The article includes new ultrasound techniques, such as tissue harmonic imaging, spatial compound imaging, three-dimensional ultrasound, elastography, contrast-enhanced ultrasound and parametric imaging. The guidelines presented above are consistent with the recommendations of the Polish Ultrasound Society. PMID:26807295

  8. [Ultrasound dissection in laparoscopic cholecystectomy].

    PubMed

    Horstmann, R; Kern, M; Joosten, U; Hohlbach, G

    1993-01-01

    An ultrasound dissector especially developed for laparoscopic surgery was used during laparoscopic cholecystectomy on 34 patients. The ultrasound power, the volume of suction and irrigation could be determined individually at the generator and activated during the operation with a foot pedal. With the dissector it was possible to fragmentate, emulgate and aspirate simultaneously fat tissue as well as infected edematous structures. The cystic artery and cystic duct, small vessels, lymphatic and connective tissue were not damaged. Therefore this system seems to be excellent for the preparation of Calot's trigonum and blunt dissection of the gallbladder out of its bed, particularly in fatty, acute or chronic infected tissue. No complications were observed within the peri- and postoperative period.

  9. Perioperative practices in thyroid surgery: An international survey.

    PubMed

    Maniakas, Anastasios; Christopoulos, Apostolos; Bissada, Eric; Guertin, Louis; Olivier, Marie-Jo; Malaise, Jacques; Ayad, Tareck

    2017-07-01

    Perioperative practices in thyroid surgery vary from one specialty, institution, or country to the next. We evaluated the preoperative, intraoperative, and postoperative practices of thyroid surgeons focusing on preoperative ultrasound, vocal cord evaluation, wound drains, and hospitalization duration, among others. A survey was sent to 7 different otolaryngology and endocrine/general surgery associations. There were 965 respondents from 52 countries. Surgeon-performed ultrasound is practiced by more than one third of respondents. Otolaryngologists perform preoperative and postoperative vocal cord evaluation more often than endocrine/general surgeons (p < .001). Sixty percent of respondents either never place drains or place drains <50% of the time in thyroid lobectomies (43% for total thyroidectomies). Outpatient thyroid surgery is most frequently performed by surgeons in the United States (63%). This epidemiologic study is the first global thyroid survey of its kind and clearly demonstrates the variability and evolving trends in thyroid surgery. © 2017 Wiley Periodicals, Inc. Head Neck 39: 1296-1305, 2017. © 2017 Wiley Periodicals, Inc.

  10. Ultrasound tissue analysis and characterization

    NASA Astrophysics Data System (ADS)

    Kaufhold, John; Chan, Ray C.; Karl, William C.; Castanon, David A.

    1999-07-01

    On the battlefield of the future, it may become feasible for medics to perform, via application of new biomedical technologies, more sophisticated diagnoses and surgery than is currently practiced. Emerging biomedical technology may enable the medic to perform laparoscopic surgical procedures to remove, for example, shrapnel from injured soldiers. Battlefield conditions constrain the types of medical image acquisition and interpretation which can be performed. Ultrasound is the only viable biomedical imaging modality appropriate for deployment on the battlefield -- which leads to image interpretation issues because of the poor quality of ultrasound imagery. To help overcome these issues, we develop and implement a method of image enhancement which could aid non-experts in the rapid interpretation and use of ultrasound imagery. We describe an energy minimization approach to finding boundaries in medical images and show how prior information on edge orientation can be incorporated into this framework to detect tissue boundaries oriented at a known angle.

  11. Intraoperative ultrasound in colorectal surgery.

    PubMed

    Greif, Franklin; Aranovich, David; Hananel, Nissim; Knizhnik, Mikhail; Belenky, Alexander

    2009-09-01

    To assess the accuracy of intraoperative ultrasound (IOUS) as a localizing technique for colorectal resections, and its impact on surgical management. Twenty-five patients (15 men and 10 women; mean age, 74.4 years) with early cancers (p T1), or polyps, not amenable to endoscopic removal were selected. IOUS was used as a sole method of intraoperative localization. Its performance was evaluated through review of preoperative colonoscopy reports, intraoperative findings, histopathology reports, and clinical follow-up. The lesions were situated in the cecum (n = 5), ascending colon (n = 3), transverse colon (n = 4), descending colon (n = 7), and rectum (n = 6). IOUS technique allowed correct localization in 24 of 25 patients, visualization of the bowel wall, and its penetration by malignant tumors. In rectal lesions, IOUS showed clearly the tumor and its margin, which facilitated performance sphincter-sparing procedure. In patients with small polyps and early cancers of colon and rectum, IOUS may be effectively used as a sole method of intraoperative localization and provide additional information that may alter decision making with regard to surgical technique. (c) 2009 Wiley Periodicals, Inc.

  12. High intensity focused ultrasound (HIFU) in tumor therapy.

    PubMed

    Sequeiros, Roberto Blanco; Joronen, Kirsi; Komar, Gaber; Koskinen, Seppo K

    HIFU (high intensity focused ultrasound) is a method in which high-frequency ultrasound is focused on a tissue in order to achieve a thermal effect and the subsequent percutaneously ablation, or tissue modulation. HIFU is non-invasive and results in an immediate tissue destruction effect corresponding to surgery, either percutaneously or through body cavities. HIFU can be utilized in the treatment of both benign and malignant tumors. In neurological diseases, focused HIFU can be used in the treatment of disorders of the basal ganglia.

  13. Preoperative Mapping of Nonmelanoma Skin Cancer Using Spatial Frequency Domain and Ultrasound Imaging

    PubMed Central

    Rohrbach, Daniel J.; Muffoletto, Daniel; Huihui, Jonathan; Saager, Rolf; Keymel, Kenneth; Paquette, Anne; Morgan, Janet; Zeitouni, Nathalie; Sunar, Ulas

    2014-01-01

    Rationale and Objectives The treatment of nonmelanoma skin cancer (NMSC) is usually by surgical excision or Mohs micrographic surgery and alternatively may include photodynamic therapy (PDT). To guide surgery and to optimize PDT, information about the tumor structure, optical parameters, and vasculature is desired. Materials and Methods Spatial frequency domain imaging (SFDI) can map optical absorption, scattering, and fluorescence parameters that can enhance tumor contrast and quantify light and photosensitizer dose. High frequency ultrasound (HFUS) imaging can provide high-resolution tumor structure and depth, which is useful for both surgery and PDT planning. Results Here, we present preliminary results from our recently developed clinical instrument for patients with NMSC. We quantified optical absorption and scattering, blood oxygen saturation (StO2), and total hemoglobin concentration (THC) with SFDI and lesion thickness with ultrasound. These results were compared to histological thickness of excised tumor sections. Conclusions SFDI quantified optical parameters with high precision, and multiwavelength analysis enabled 2D mappings of tissue StO2 and THC. HFUS quantified tumor thickness that correlated well with histology. The results demonstrate the feasibility of the instrument for noninvasive mapping of optical, physiological, and ultrasound contrasts in human skin tumors for surgery guidance and therapy planning. PMID:24439339

  14. 3-D ultrasound guidance of surgical robotics: a feasibility study.

    PubMed

    Pua, Eric C; Fronheiser, Matthew P; Noble, Joanna R; Light, Edward D; Wolf, Patrick D; von Allmen, Daniel; Smith, Stephen W

    2006-11-01

    Laparoscopic ultrasound has seen increased use as a surgical aide in general, gynecological, and urological procedures. The application of real-time, three-dimensional (RT3D) ultrasound to these laparoscopic procedures may increase information available to the surgeon and serve as an additional intraoperative guidance tool. The integration of RT3D with recent advances in robotic surgery also can increase automation and ease of use. In this study, a 1-cm diameter probe for RT3D has been used laparoscopically for in vivo imaging of a canine. The probe, which operates at 5 MHz, was used to image the spleen, liver, and gall bladder as well as to guide surgical instruments. Furthermore, the three-dimensional (3-D) measurement system of the volumetric scanner used with this probe was tested as a guidance mechanism for a robotic linear motion system in order to simulate the feasibility of RT3D/robotic surgery integration. Using images acquired with the 3-D laparoscopic ultrasound device, coordinates were acquired by the scanner and used to direct a robotically controlled needle toward desired in vitro targets as well as targets in a post-mortem canine. The rms error for these measurements was 1.34 mm using optical alignment and 0.76 mm using ultrasound alignment.

  15. Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters

    DTIC Science & Technology

    2015-12-01

    1 AD_________________ AWARD NUMBER: W81XWH-08-2-0162 TITLE: Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War...Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters 5a. CONTRACT NUMBER 5b. GRANT NUMBER: W81XWH-08-2-0162 5c...Purpose: To demonstrate that 1) ultrasound guided foreign body removal (USFBR) is superior to conventional surgery in the cadaver model, 2) USFBR can be

  16. The intensity dependence of lesion position shift during focused ultrasound surgery.

    PubMed

    Meaney, P M; Cahill, M D; ter Haar, G R

    2000-03-01

    Knowledge of the spatial distribution of intensity loss from an ultrasonic beam is critical for predicting lesion formation in focused ultrasound (US) surgery (FUS). To date, most models have used linear propagation models to predict intensity profiles required to compute the temporally varying temperature distributions used to compute thermal dose contours. These are used to predict the extent of thermal damage. However, these simulations fail to describe adequately the abnormal lesion formation behaviour observed during ex vivo experiments in cases for which the transducer drive levels are varied over a wide range. In such experiments, the extent of thermal damage has been observed to move significantly closer to the transducer with increased transducer drive levels than would be predicted using linear-propagation models. The first set of simulations described herein use the KZK (Khokhlov-Zabolotskaya-Kuznetsov) nonlinear propagation model with the parabolic approximation for highly focused US waves to demonstrate that both the peak intensity and the lesion positions do, indeed, move closer to the transducer. This illustrates that, for accurate modelling of heating during FUS, nonlinear effects should be considered. Additionally, a first order approximation has been employed that attempts to account for the abnormal heat deposition distributions that accompany high transducer drive level FUS exposures where cavitation and boiling may be present. The results of these simulations are presented. It is suggested that this type of approach may be a useful tool in understanding thermal damage mechanisms.

  17. Ultrasound-guided supraclavicular block: outcome of 510 consecutive cases.

    PubMed

    Perlas, Anahi; Lobo, Giovanni; Lo, Nick; Brull, Richard; Chan, Vincent W S; Karkhanis, Reena

    2009-01-01

    Supraclavicular brachial plexus block provides consistently effective anesthesia to the upper extremity. However, traditional nerve localization techniques may be associated with a high risk of pneumothorax. In the present study, we report block success and clinical outcome data from 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery. After institutional review board approval, the outcome of 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery was reviewed. Real-time ultrasound guidance was used with a high-frequency linear probe. The neurovascular structures were imaged on short axis, and the needle was inserted using an in-plane technique with either a medial-to-lateral or lateral-to-medial orientation. Five hundred ten ultrasound-guided supraclavicular blocks were performed (50 inpatients, 460 outpatients) by 47 different operators at different levels of training over a 24-month period. Successful surgical anesthesia was achieved in 94.6% of patients after a single attempt; 2.8% required local anesthetic supplementation of a single peripheral nerve territory; and 2.6% received an unplanned general anesthetic. No cases of clinically symptomatic pneumothorax developed. Complications included symptomatic hemidiaphragmatic paresis (1%), Horner syndrome (1%), unintended vascular punctures (0.4%), and transient sensory deficits (0.4%). Ultrasound-guided supraclavicular block is associated with a high rate of successful surgical anesthesia and a low rate of complications and thus may be a safe alternative for both inpatients and outpatients. Severe underlying respiratory disease and coagulopathy should remain a contraindication for this brachial plexus approach.

  18. Ultrasound contrast agent fabricated from microbubbles containing instant adhesives, and its ultrasound imaging ability

    NASA Astrophysics Data System (ADS)

    Makuta, T.; Tamakawa, Y.

    2012-04-01

    Non-invasive surgery techniques and drug delivery system with acoustic characteristics of ultrasound contrast agent have been studied intensively in recent years. Ultrasound contrast agent collapses easily under the blood circulating and the ultrasound irradiating because it is just a stabilized bubble without solid-shell by surface adsorption of surfactant or lipid. For improving the imaging stability, we proposed the fabrication method of the hollow microcapsule with polymer shell, which can be fabricated just blowing vapor of commonly-used instant adhesive (Cyanoacrylate monomer) into water as microbubbles. Therefore, the cyanoacrylate vapor contained inside microbubble initiates polymerization on the gasliquid interface soon after microbubbles are generated in water. Consequently, hollow microspheres coated by cyanoacrylate thin film are generated. In this report, we revealed that diameter distributions of microbubbles and microcapsules were approximately same and most of them were less than 10 μm, that is, smaller than blood capillary. In addition, we also revealed that hollow microcapsules enhanced the acoustic signal especially in the harmonic contrast imaging and were broken or agglomerated under the ultrasound field. As for the yield of hollow microcapsules, we revealed that sodium dodecyl sulfate addition to water phase instead of deoxycolic acid made the fabrication yield increased.

  19. Ultrasound estimation of volume of postoperative pleural effusion in cardiac surgery patients.

    PubMed

    Usta, Engin; Mustafi, Migdat; Ziemer, Gerhard

    2010-02-01

    The aim of this study was to establish a practical simplified formula to facilitate the management of a frequently occurring postoperative complication, pleural effusion. Chest ultrasonography with better sensitivity and reliability in the diagnosis of pleural effusions than chest X-ray can be repeated serially at the bedside without any radiation risk. One hundred and fifty patients after cardiac surgery with basal pleural opacity on chest X-ray have been included in our prospective observational study during a two-year period. Effusion was confirmed on postoperative day (POD) 5.9+/-3.2 per chest ultrasound sonography. Inclusion criteria for subsequent thoracentesis based on clinical grounds alone and were not protocol-driven. Major inclusion criteria were: dyspnea and peripheral oxygen saturation (SpO(2)) levels < or = 92% and the maximal distance between mid-height of the diaphragm and visceral pleura (D > or = 30 mm). One hundred and thirty-five patients (90%) were drained with a 14-G needle if according to the simplified formula: V (ml)=[16 x D (mm)] the volume of the pleural effusion was around 500 ml. The success rate of obtaining fluid was 100% without any complications. There is a high accuracy between the estimated and drained pleural effusion. Simple quantification of pleural effusion enables time and cost-effective decision-making for thoracentesis in postoperative patients.

  20. Ultrasound imaging of the nose in septorhinoplasty patients.

    PubMed

    Stenner, Markus; Rudack, Claudia

    2015-10-01

    Detailed preoperative planning based on available clinical information is an essential component of determining septorhinoplasty outcome. In addition to rhinoscopy and airway measurements, preoperative photographs are the only image modalities that are regularly used in septorhinoplasty patients and contribute to the preoperative planning of the surgery. The aim of this study was to evaluate the use of high-resolution ultrasonography in septorhinoplasty patients before surgery and during follow-up. We examined 35 patients before and after open septorhinoplasty using 12- and 15-MHz B-mode, linear array transducer ultrasound in noncontact mode. The patients presented with a variety of different functional and aesthetic problems, and all underwent septorhinoplasty for septal modification, and tip and dorsum refinement. The mean follow-up time for ultrasound after surgery was 4.5 weeks. Soft tissue, cartilaginous, and bony structures of the nose could be well-visualised. In the untreated nose, functional and aesthetic characteristics as well as preoperative anatomy relevant for the planning of the surgery could be documented. Surgical modifications of the treated nose postoperatively, that is, osteotomies, inserted spreader grafts, diced cartilage in fascia, and tip sutures could be visualized and followed. Ultrasonography of the nose with a high-frequency transducer may be a helpful tool during preoperative planning and postoperative follow-up in septorhinoplasty patients and might be a reasonable completion to the common photographic and functional diagnostic.

  1. Varying ultrasound power level to distinguish surgical instruments and tissue.

    PubMed

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  2. Ultrasound-guided continuous interscalene block: the influence of local anesthetic background delivery method on postoperative analgesia after shoulder surgery: a randomized trial.

    PubMed

    Hamdani, Mehdi; Chassot, Olivier; Fournier, Roxane

    2014-01-01

    Automated bolus delivery has recently been shown to reduce local anesthetic consumption and improve analgesia, compared with continuous infusion, in continuous sciatic and epidural block. However, there are few data on the influence of local anesthetic delivery method on local anesthetic consumption following interscalene blockade. This randomized, double-blind trial was designed to determine whether hourly automated perineural boluses (4 mL) of local anesthesia delivered with patient-controlled pro re nata (PRN, on demand) boluses would result in a reduction in total local anesthesia consumption during continuous interscalene blockade after shoulder surgery compared with continuous perineural infusion (4 mL/h) plus patient-controlled PRN boluses. One hundred one patients undergoing major shoulder surgery under general anesthesia with ultrasound-guided continuous interscalene block were randomly assigned to receive 0.2% ropivacaine via interscalene end-hole catheter either by continuous infusion 4 mL/h (n = 50) or as automated bolus 4 mL/h (n = 51). Both delivery methods were combined with 5 mL PRN boluses of 0.2% ropivacaine with a lockout time of 30 minutes. Postoperative number of PRN boluses, 24- and 48-hour local anesthetic consumption, pain scores, rescue analgesia (morphine), and adverse events were recorded. There were no significant differences in either the number of PRN ropivacaine boluses or total 48 hour local anesthetic consumption between the groups (18.5 [11-25.2] PRN boluses in the continuous infusion group vs 17 [8.5-29] PRN boluses in the automated bolus group). Postoperative pain was similar in both groups; on day 2, the median average pain score was 4 (2-6) in the continuous infusion group versus 3 (2-5) in the automated bolus group (P = 0.54). Nor were any statistically significant intergroup differences observed with respect to morphine rescue, incidence of adverse events, or patient satisfaction. In continuous interscalene blockade under

  3. Medical ultrasound education for bioengineers

    NASA Astrophysics Data System (ADS)

    Vaezy, Shahram

    2005-04-01

    The widespread adoption of ultrasound technologies in medicine has necessitated the development of educational programs to address the growing demand for trained expertise in both academia and industry. The demand has been especially great in the field of therapeutic ultrasound that has experienced a significant level of research and development activities in the past decade. The applications cover a wide range including cancer treatment, hemorrhage control, cardiac ablation, gene therapy, and cosmetic surgery. A comprehensive educational program in ultrasound is well suited for bioengineering departments at colleges and universities. Our educational program for students in Bioengineering at the University of Washington includes a year-long coursework covering theory and practice of ultrasound, conducting research projects, attending and presenting at weekly seminars on literature survey, presentations at scientific meetings, and attending specialized workshops offered by various institutions for specific topics. An important aspect of this training is its multi-disciplinary approach, encompassing science, engineering, and medicine. The students are required to build teams with expertise in these disciplines. Our experience shows that these students are well prepared for careers in academia, conducting cutting edge research, as well as industry, being involved in the transformation of research end-products to commercially viable technology.

  4. Solid, Cystic, and Tubular: Novice Ultrasound Skills Training Using a Versatile, Affordable Practice Model.

    PubMed

    Sevak, Shruti; Lurvey, Benjamin; Woodfin, Ashley A; Hothem, Zachary; Callahan, Rose E; Robbins, James; Ziegler, Kathryn

    2018-04-09

    In spite of the recognized benefits of ultrasound, many physicians have little experience with using ultrasound to perform procedures. Many medical schools and residency programs lack a formal ultrasound training curriculum. We describe an affordable ultrasound training curriculum and versatile, inexpensive practice model. Participants underwent a didactic session to teach the theory required to perform ultrasound-guided procedures. Motor skills were taught using a practice model incorporating analogs of common anatomic and pathologic structures into an opacified gelatin substrate. The Marcia and Eugene Applebaum Simulation Learning Institute, Beaumont Hospital, Royal Oak, MI; a private nonprofit tertiary care hospital associated with the OUWB School of Medicine, Rochester, MI. The model was tested in a cohort of 50 medical students and general surgery residents. The gelatin model can be constructed for $1.03 per learner. The solid, cystic, and vascular structural analogs were readily identifiable on ultrasound and easily differentiated based on their echotextures. Eighty-four percent of participants successfully aspirated the cystic structure, 88% successfully biopsied a portion of the solid structure, and 76% successfully cannulated the tubular structure. Overall, 82% of participants achieved a passing score for the exercise based on a validated Objective Structured Assessment of Technical Skill instrument. There were no significant differences between the medical students and residents. This model can be used to teach basic ultrasound skills such as aspiration, biopsy, and vessel cannulation, providing a foundation for the use of ultrasound in a broad range of clinical procedures, as well as providing practice opportunities for medical students and residents to gain increased ultrasound competency and confidence. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. The effect of morphine added to bupivacaine in ultrasound guided transversus abdominis plane (TAP) block for postoperative analgesia following lower abdominal cancer surgery, a randomized controlled study.

    PubMed

    El Sherif, Fatma Adel; Mohamed, Sahar Abdel-Baky; Kamal, Shereen Mamdouh

    2017-06-01

    Transversus abdominis plane (TAP) block used for management of surgical abdominal pain by injecting local anesthetics into the plane between the internal oblique and transversus abdominis muscles. We aimed to explore the effect of adding morphine to bupivacaine in ultrasound guided TAP-block in patients undergoing lower abdominal cancer surgery. Randomized, double-blind, prospective study. Clinical trial identifier: NCT02566096. Academic medical center. Sixty patients were enrolled in this study after ethical committee approval. Patients divided into 2 groups (30 each): Bupivacaine group (GB): given ultrasound guided TAP-block 20ml 0.5% bupivacaine diluted in 20ml saline; Morphine group (GM): given ultrasound guided TAP-block with 20ml 0.5% bupivacaine+10mg morphine sulphate diluted in 20ml saline. Patients were observed for total morphine consumption, time for first request of rescue analgesia, sedation scores, hemodynamics and side effects for 24h postoperatively. Morphine added to bupivacaine in TAP block compared to bupivacaine alone reduced total morphine consumption (5.33±1.28mg) (10.70±3.09mg) respectively (p<0.001), prolonged the time to first request of analgesia (10.40±4.96h) (6.97±3.26h) respectively (p<0.008), with a statistically significant decrease in (VAS-M) in GM compared with GB at 12h postoperatively (p<0.002). No significant differences in hemodynamics, respiratory rate, oxygen saturation, sedation score, and side effects except for nausea were observed (p>0.05). Addition of morphine to bupivacaine in TAP block is effective method for pain management in patients undergoing major abdominal cancer surgery without serious side effects. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Preliminary ex vivo feasibility study on targeted cell surgery by high intensity focused ultrasound (HIFU).

    PubMed

    Wang, Zhi Biao; Wu, Junru; Fang, Liao Qiong; Wang, Hua; Li, Fa Qi; Tian, Yun Bo; Gong, Xiao Bo; Zhang, Hong; Zhang, Lian; Feng, Ruo

    2011-04-01

    High intensity focused ultrasound (HIFU) has become a new noninvasive surgical modality in medicine. A portion of tissue seated inside a patient's body may experience coagulative necrosis after a few seconds of insonification by high intensity focused ultrasound (US) generated by an extracorporeal focusing US transducer. The region of tissue affected by coagulative necrosis (CN) usually has an ellipsoidal shape when the thermal effect due to US absorption plays the dominant role. Its long and short axes are parallel and perpendicular to the US propagation direction respectively. It was shown by numerical computations using a nonlinear Gaussian beams model to describe the sound field in a focal zone and ex vivo experiments that the dimension of the short and long axes of the tissue which experiences CN can be as small as 50μm and 250μm respectively after one second exposure of US pulse (the spatial and pulse average acoustic power is on the order of tens of Watts and the local acoustic spatial and temporal pulse averaged intensity is on the order of 3×10(4)W/cm(2)) generated by a 1.6MHz HIFU transducer of 12cm diameter and 11cm geometric focal length (f-number=0.92). The concept of thermal dose of cumulative equivalent minutes was used to describe the possible tissue coagulative necrosis generated by HIFU. The numbers of cells which suffered CN were estimated to be on the order of 40. This result suggests that HIFU is able to interact with tens of cells at/near its focal zone while keeping the neighboring cells minimally affected, and thus the targeted cell surgery may be achievable. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Comparison of postoperative refractive outcomes: IOLMaster® versus immersion ultrasound.

    PubMed

    Whang, Woong-Joo; Jung, Byung-Ju; Oh, Tae-Hoon; Byun, Yong-Soo; Joo, Choun-Ki

    2012-01-01

    To compare the postoperative refractive outcomes between IOLMaster biometry (Carl Zeiss Meditec, Inc., Dublin, CA) and immersion ultrasound biometry for axial length measurements. Refractive outcomes in 354 eyes were compared using the IOLMaster and the immersion ultrasound biometry. Predicted refraction was determined using manual keratometry and the SRK-T formula with personalized A-constant. The axial lengths measured using the IOLMaster and immersion ultrasound were 24.49 ± 2.11 and 24.46 ± 2.11 mm, respectively, and the difference was significant (P < .05). The mean errors were 0.000 ± 0.578 D with the IOLMaster, and 0.000 ± 0.599 D with the immersion ultrasound, but the difference was not significant. The mean absolute error was smaller with the IOLMaster than with immersion ultrasound (0.463 ± 0.341 vs 0.479 ± 0.359 D), but the difference was not significant. IOLMaster biometry yields highly accurate results in cataract surgery. However, if the IOLMaster is unavailable, immersion ultrasound biometry with personalized intraocular lens constants is an acceptable alternative. Copyright 2012, SLACK Incorporated.

  8. Driving Circuitry for Focused Ultrasound Noninvasive Surgery and Drug Delivery Applications

    PubMed Central

    El-Desouki, Munir M.; Hynynen, Kullervo

    2011-01-01

    Recent works on focused ultrasound (FUS) have shown great promise for cancer therapy. Researchers are continuously trying to improve system performance, which is resulting in an increased complexity that is more apparent when using multi-element phased array systems. This has led to significant efforts to reduce system size and cost by relying on system integration. Although ideas from other fields such as microwave antenna phased arrays can be adopted in FUS, the application requirements differ significantly since the frequency range used in FUS is much lower. In this paper, we review recent efforts to design efficient power monitoring, phase shifting and output driving techniques used specifically for high intensity focused ultrasound (HIFU). PMID:22346589

  9. Driving circuitry for focused ultrasound noninvasive surgery and drug delivery applications.

    PubMed

    El-Desouki, Munir M; Hynynen, Kullervo

    2011-01-01

    Recent works on focused ultrasound (FUS) have shown great promise for cancer therapy. Researchers are continuously trying to improve system performance, which is resulting in an increased complexity that is more apparent when using multi-element phased array systems. This has led to significant efforts to reduce system size and cost by relying on system integration. Although ideas from other fields such as microwave antenna phased arrays can be adopted in FUS, the application requirements differ significantly since the frequency range used in FUS is much lower. In this paper, we review recent efforts to design efficient power monitoring, phase shifting and output driving techniques used specifically for high intensity focused ultrasound (HIFU).

  10. Cost-utility analysis of great saphenous vein ablation with radiofrequency, foam and surgery in the emerging health-care setting of Thailand.

    PubMed

    Siribumrungwong, Boonying; Noorit, Pinit; Wilasrusmee, Chumpon; Leelahavarong, Pattara; Thakkinstian, Ammarin; Teerawattananon, Yot

    2016-09-01

    To conduct economic evaluations of radiofrequency ablation, ultrasound-guided foam sclerotherapy and surgery for great saphenous vein ablation. A cost-utility and cohort analysis from societal perspective was performed to estimate incremental cost-effectiveness ratio. Transitional probabilities were from meta-analysis. Direct medical, direct non-medical, indirect costs, and utility were from standard Thai costings and cohort. Probabilistic sensitivity analysis was performed to assess parameter uncertainties. Seventy-seven patients (31 radiofrequency ablation, 19 ultrasound-guided foam sclerotherapy, and 27 surgeries) were enrolled from October 2011 to February 2013. Compared with surgery, radiofrequency ablation costed 12,935 and 20,872 Baht higher, whereas ultrasound-guided foam sclerotherapy costed 6159 lower and 1558 Bath higher for outpatient and inpatient, respectively. At one year, radiofrequency ablation had slightly lower quality-adjusted life-year, whereas ultrasound-guided foam sclerotherapy yielded additional 0.025 quality-adjusted life-year gained. Because of costing lower and greater quality-adjusted life-year than other compared alternatives, outpatient ultrasound-guided foam sclerotherapy was an option being dominant. Probabilistic sensitivity analysis resulted that at the Thai ceiling threshold of 160,000 Baht/quality-adjusted life-year gained, ultrasound-guided foam sclerotherapy had chances of 0.71 to be cost-effective. Ultrasound-guided foam sclerotherapy seems to be cost-effective for treating great saphenous vein reflux compared to surgery in Thailand at one-year results. © The Author(s) 2015.

  11. [Ultrasound monitoring of consolidation processes in fractures of long tubular bones in osteosynthesis using bioactive implants].

    PubMed

    Zavadovskaia, V D; Popov, V P; Akbasheva, O E; Grigor'ev, E G; Druzhinina, T V

    2014-01-01

    To show the capabilities of ultrasound monitoring to assess consolidation processes in fractures of long tubular bones in the use of bioactive material-containing implants. Eighty-two (45.1%) patients whose bone fragments had been fixed with bioactive material-coated plates and 100 (54.9%) patients with bioinert material-coated ones were examined. Consolidation changes were estimated by ultrasound and X-ray studies 2, 4, 6, and 12 months after surgery. Bone metabolic changes were determined by US osteometry 2 months following surgery. Ultrasound data were compared with the biochemical markers: C-terminal telopeptide (CrossLaps) and osteocalcin. Ultrasound monitoring of the rates of consolidation and the time course of changes in bone strength versus the biochemical markers established the positive effect of bioactiveplates on the process of consolidation in fractures of tubular bones and made it possible to consider local osteopenic syndrome to be a prognostically favorable sign of timely callus formation.

  12. American Thyroid Association statement on preoperative imaging for thyroid cancer surgery.

    PubMed

    Yeh, Michael W; Bauer, Andrew J; Bernet, Victor A; Ferris, Robert L; Loevner, Laurie A; Mandel, Susan J; Orloff, Lisa A; Randolph, Gregory W; Steward, David L

    2015-01-01

    The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging.

  13. TU-B-210-01: MRg HIFU - Bone and Soft Tissue Tumor Ablation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghanouni, P.

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advancedmore » techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.« less

  14. TU-B-210-02: MRg HIFU - Advanced Approaches for Ablation and Hyperthermia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moonen, C.

    2015-06-15

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advancedmore » techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.« less

  15. Cost comparison between uterine-sparing fibroid treatments one year following treatment

    PubMed Central

    2014-01-01

    Background To compare one-year all-cause and uterine fibroid (UF)-related direct costs in patients treated with one of the following three uterine-sparing procedures: magnetic resonance-guided focused ultrasound (MRgFUS), uterine artery embolization (UAE) and myomectomy. Methods This retrospective observational cohort study used healthcare claims for several million individuals with healthcare coverage from employers in the MarketScan Database for the period 2003–2010. UF patients aged 25–54 on their first UF procedure (index) date with 366-day baseline experience, 366-day follow-up period, continuous health plan enrollment during baseline and follow-up, and absence of any baseline UF procedures were included in the final sample. Cost outcomes were measured by allowed charges (sum of insurer-paid and patient-paid amounts). UF-related cost was defined as difference in mean cost between study cohorts and propensity-score-matched control cohorts without UF. Multivariate adjustment of cost outcomes was conducted using generalized linear models. Results The study sample comprised 14,426 patients (MRgFUS = 14; UAE = 4,092; myomectomy = 10,320) with a higher percent of older patients in MRgFUS cohort (71% vs. 50% vs. 12% in age-group 45–54, P < 0.001). Adjusted all-cause mean cost was lowest for MRgFUS ($19,763; 95% CI: $10,425-$38,694) followed by myomectomy ($20,407; 95% CI: $19,483-$21,381) and UAE ($25,019; 95% CI: $23,738-$26,376) but without statistical significance. Adjusted UF-related costs were also not significantly different between the three procedures. Conclusions Adjusted all-cause and UF-related costs at one year were not significantly different between patients undergoing MRgFUS, myomectomy and UAE. PMID:25512868

  16. Overview of Therapeutic Ultrasound Applications and Safety Considerations

    PubMed Central

    Miller, Douglas; Smith, Nadine; Bailey, Michael; Czarnota, Gregory; Hynynen, Kullervo; Makin, Inder

    2013-01-01

    Summary Applications of ultrasound in medicine for therapeutic purposes have been an accepted and beneficial use of ultrasonic biological effects for many years. Low power ultrasound of about 1 MHz frequency has been widely applied since the 1950s for physical therapy in conditions such as tendinitis or bursitis. In the 1980s, high pressure-amplitude shockwaves came into use for mechanically resolving kidney stones, and “lithotripsy” rapidly replaced surgery as the most frequent treatment choice. The use of ultrasonic energy for therapy continues to expand, and approved applications now include uterine fibroid ablation, cataract removal (phacoemulsification), surgical tissue cutting and hemostasis, transdermal drug delivery, and bone fracture healing, among others. Undesirable bioeffects can occur including burns for thermal-based therapies and significant hemorrhage for mechanical-based therapies (e. g. lithotripsy). In all these therapeutic applications for bioeffects of ultrasound, standardization, ultrasound dosimetry, benefits assurance and side-effects risk minimization must be carefully considered in order to insure an optimal benefit to risk ratio for the patient. Therapeutic ultrasound typically has well-defined benefits and risks, and therefore presents a tractable safety problem to the clinician. However, safety information can be scattered, confusing or subject to commercial conflict of interest. Of paramount importance for managing this problem is the communication of practical safety information by authoritative groups, such as the AIUM, to the medical ultrasound community. In this overview, the Bioeffects Committee outlines the wide range of therapeutic ultrasound methods, which are in clinical use or under study, and provides general guidance for assuring therapeutic ultrasound safety. PMID:22441920

  17. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    PubMed

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the

  18. A Cost-effectiveness Analysis of Surgery, Endothermal Ablation, Ultrasound-guided Foam Sclerotherapy and Compression Stockings for Symptomatic Varicose Veins.

    PubMed

    Marsden, G; Perry, M; Bradbury, A; Hickey, N; Kelley, K; Trender, H; Wonderling, D; Davies, A H

    2015-12-01

    The aim was to investigate the cost-effectiveness of interventional treatment for varicose veins (VV) in the UK NHS, and to inform the national clinical guideline on VV, published by the National Institute of Health and Care Excellence. An economic analysis was constructed to compare the cost-effectiveness of surgery, endothermal ablation (ETA), ultrasound-guided foam sclerotherapy (UGFS), and compression stockings (CS). The analysis was based on a Markov decision model, which was developed in consultation with members of the NICE guideline development group (GDG). The model had a 5-year time horizon, and took the perspective of the UK National Health Service. Clinical inputs were based on a network meta-analysis (NMA), informed by a systematic review of the clinical literature. Outcomes were expressed as costs and quality-adjusted life years (QALYs). All interventional treatments were found to be cost-effective compared with CS at a cost-effectiveness threshold of £20,000 per QALY gained. ETA was found to be the most cost-effective strategy overall, with an incremental cost-effectiveness ratio of £3,161 per QALY gained compared with UGFS. Surgery and CS were dominated by ETA. Interventional treatment for VV is cost-effective in the UK NHS. Specifically, based on current data, ETA is the most cost-effective treatment in people for whom it is suitable. The results of this research were used to inform recommendations within the NICE guideline on VV. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Ultrasound-guided urinary bladder biopsy through a urinary catheter in a bitch.

    PubMed

    Lopez, Julio; Norman, Brian C

    2014-01-01

    A 34.4 kg 5 yr old spayed female mixed-breed dog was presented for evaluation of a urinary bladder mass. The dog had a recent onset of hematuria and stranguria but otherwise appeared to be healthy. Abdominal ultrasound revealed a mass in the urinary bladder. The dog was sedated and a 10-French rubber catheter that had the blunt end removed was passed from the urethra to the urinary bladder. Using ultrasound guidance, ellipsoid cup biopsy forceps were advanced through the rubber catheter to the urinary bladder mass and biopsies were successfully obtained. The dog was discharged from the hospital a few hours after the procedure. Histopathology of the mass was consistent with polypoid cystitis. Follow-up surgical removal of the polyp was uneventful, and histopathology confirmed the presurgical biopsy diagnosis. Procurement of urinary bladder biopsies through a urinary catheter with ultrasound guidance was used as a minimally invasive alternative to either cystoscopy or surgery in a bitch. Use of this technique achieved a diagnosis without the need for specialized endoscopic equipment, anesthesia, or surgery.

  20. Ultrasound in differential diagnosis of periapical radiolucencies: A radiohistopathological study

    PubMed Central

    Khambete, Neha; Kumar, Rahul

    2015-01-01

    Objectives: To evaluate the efficacy of ultrasound in differential diagnosis of periapical radiolucencies. Materials and Methods: Ten patients aged between 19 years and 40 years with periapical lesions associated with anterior maxillary or mandibular teeth were selected and consented for the study. Pre-operative periapical radiographs were obtained. Measurements and provisional diagnoses of the apical areas were made by two specialist observers on two separate occasions. Preoperative ultrasound examinations with Doppler flowmetry were then performed and the images assessed by two specialist observers for the size, contents, vascular supply and a provisional diagnosis made as to whether the lesion was a cyst or granuloma. Endodontic surgery was performed including curettage of the apical tissues to enable histopathological investigation, which provided the gold standard diagnosis. All measurements and findings were compared and statistically analyzed. Results: Total 10 lesions were identified in 10 patients. On periapical radiographs, lesions were readily identified but observers were unable to differentiate granuloma from cyst using either modality. Where sufficient buccal cortical bone had been resorbed, ultrasound imaging was simple but underestimated the size of the lesions compared with periapical radiographs. In all cases, the ultrasound diagnosis agreed with the histopathological gold standard. Conclusion: Ultrasonography (USG) can provide accurate information about the nature of intraosseous lesions of the jaws before any surgical procedure. It is proposed that USG with Doppler flowmetry can provide an additional diagnostic tool without invasive surgery, where treatment option is nonsurgical. PMID:25657525

  1. Axillary Ultrasound After Neoadjuvant Chemotherapy and Its Impact on Sentinel Lymph Node Surgery: Results From the American College of Surgeons Oncology Group Z1071 Trial (Alliance)

    PubMed Central

    Boughey, Judy C.; Ballman, Karla V.; Hunt, Kelly K.; McCall, Linda M.; Mittendorf, Elizabeth A.; Ahrendt, Gretchen M.; Wilke, Lee G.; Le-Petross, Huong T.

    2015-01-01

    Purpose The American College of Surgeons Oncology Group Z1071 trial reported a 12.6% false-negative rate (FNR) for sentinel lymph node (SLN) surgery after neoadjuvant chemotherapy (NAC) in cN1 disease. Patients were not selected for surgery based on response, but a secondary end point was to determine whether axillary ultrasound (AUS) after NAC after fine-needle aspiration cytology can identify abnormal nodes and guide patient selection for SLN surgery. Patients and Methods Patients with T0-4, N1-2, M0 breast cancer underwent AUS after neoadjuvant chemotherapy. AUS images were centrally reviewed and classified as normal or suspicious lymph nodes. AUS findings were tested for association with pathologic nodal status and SLN FNR. The impact of AUS results to select patients for SLN surgery to reduce the FNR was assessed. Results Postchemotherapy AUS images were reviewed for 611 patients. One hundred thirty (71.8%) of 181 AUS-suspicious patients were node positive at surgery compared with 243 (56.5%) of 430 AUS-normal patients (P < .001). Patients with AUS-suspicious nodes had a greater number of positive nodes and greater metastasis size (P < .001). The SLN FNR was not different based on AUS results; however, using a strategy where only patients with normal AUS undergo SLN surgery would potentially reduce the FNR in Z1071 patients with ≥ two SLNs removed from 12.6% to 9.8% when preoperative AUS results are considered as part of SLN surgery. Conclusion AUS is recommended after chemotherapy to guide axillary surgery. An FNR of 9.8% with the combination of AUS and SLN surgery would be acceptable for the adoption of SLN surgery for women with node-positive breast cancer treated with neoadjuvant chemotherapy. PMID:25646192

  2. Axillary Ultrasound After Neoadjuvant Chemotherapy and Its Impact on Sentinel Lymph Node Surgery: Results From the American College of Surgeons Oncology Group Z1071 Trial (Alliance).

    PubMed

    Boughey, Judy C; Ballman, Karla V; Hunt, Kelly K; McCall, Linda M; Mittendorf, Elizabeth A; Ahrendt, Gretchen M; Wilke, Lee G; Le-Petross, Huong T

    2015-10-20

    The American College of Surgeons Oncology Group Z1071 trial reported a 12.6% false-negative rate (FNR) for sentinel lymph node (SLN) surgery after neoadjuvant chemotherapy (NAC) in cN1 disease. Patients were not selected for surgery based on response, but a secondary end point was to determine whether axillary ultrasound (AUS) after NAC after fine-needle aspiration cytology can identify abnormal nodes and guide patient selection for SLN surgery. Patients with T0-4, N1-2, M0 breast cancer underwent AUS after neoadjuvant chemotherapy. AUS images were centrally reviewed and classified as normal or suspicious lymph nodes. AUS findings were tested for association with pathologic nodal status and SLN FNR. The impact of AUS results to select patients for SLN surgery to reduce the FNR was assessed. Postchemotherapy AUS images were reviewed for 611 patients. One hundred thirty (71.8%) of 181 AUS-suspicious patients were node positive at surgery compared with 243 (56.5%) of 430 AUS-normal patients (P < .001). Patients with AUS-suspicious nodes had a greater number of positive nodes and greater metastasis size (P < .001). The SLN FNR was not different based on AUS results; however, using a strategy where only patients with normal AUS undergo SLN surgery would potentially reduce the FNR in Z1071 patients with ≥ two SLNs removed from 12.6% to 9.8% when preoperative AUS results are considered as part of SLN surgery. AUS is recommended after chemotherapy to guide axillary surgery. An FNR of 9.8% with the combination of AUS and SLN surgery would be acceptable for the adoption of SLN surgery for women with node-positive breast cancer treated with neoadjuvant chemotherapy. © 2015 by American Society of Clinical Oncology.

  3. Accuracy of contrast-enhanced ultrasound in the detection of bladder cancer

    PubMed Central

    Nicolau, C; Bunesch, L; Peri, L; Salvador, R; Corral, J M; Mallofre, C; Sebastia, C

    2011-01-01

    Objective To assess the accuracy contrast-enhanced ultrasound (CEUS) in bladder cancer detection using transurethral biopsy in conventional cystoscopy as the reference standard and to determine whether CEUS improves the bladder cancer detection rate of baseline ultrasound. Methods 43 patients with suspected bladder cancer underwent conventional cystoscopy with transurethral biopsy of the suspicious lesions. 64 bladder cancers were confirmed in 33 out of 43 patients. Baseline ultrasound and CEUS were performed the day before surgery and the accuracy of both techniques for bladder cancer detection and number of detected tumours were analysed and compared with the final diagnosis. Results CEUS was significantly more accurate than ultrasound in determining presence or absence of bladder cancer: 88.37% vs 72.09%. Seven of eight uncertain baseline ultrasound results were correctly diagnosed using CEUS. CEUS sensitivity was also better than that of baseline ultrasound per number of tumours: 65.62% vs 60.93%. CEUS sensitivity for bladder cancer detection was very high for tumours larger than 5 mm (94.7%) but very low for tumours <5 mm (20%) and also had a very low negative predictive value (28.57%) in tumours <5 mm. Conclusion CEUS provided higher accuracy than baseline ultrasound for bladder cancer detection, being especially useful in non-conclusive baseline ultrasound studies. PMID:21123306

  4. [Focused ultrasound therapy: current status and potential applications in neurosurgery].

    PubMed

    Dervishi, E; Aubry, J-F; Delattre, J-Y; Boch, A-L

    2013-12-01

    High Intensity Focused Ultrasound (HIFU) therapy is an innovative approach for tissue ablation, based on high intensity focused ultrasound beams. At the focus, HIFU induces a temperature elevation and the tissue can be thermally destroyed. In fact, this approach has been tested in a number of clinical studies for the treatment of several tumors, primarily the prostate, uterine, breast, bone, liver, kidney and pancreas. For transcranial brain therapy, the skull bone is a major limitation, however, new adaptive techniques of phase correction for focusing ultrasound through the skull have recently been implemented by research systems, paving the way for HIFU therapy to become an interesting alternative to brain surgery and radiotherapy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  5. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algin, Oktay, E-mail: droktayalgin@gmail.com; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-02-15

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improvedmore » clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.« less

  6. Principles of Billing for Diagnostic Ultrasound in the Office and Operating Room.

    PubMed

    Grasu, Beatrice L; Wolock, Bruce S; Sedgley, Matthew D; Murphy, Michael S

    2018-05-08

    Ultrasound is becoming more prevalent as physicians gain comfort in its diagnostic and therapeutic uses. It allows for both static and dynamic evaluation of conditions and assists in therapeutic injections of joints and tendons. Proper technique is necessary for successful use of this modality. Appropriate coding for physician reimbursement is required. We discuss common wrist and hand pathology for which ultrasound may be useful as an adjunct to diagnosis and treatment and provide an overview of technique and reimbursement codes when using ultrasound in a variety of situations. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. American Thyroid Association Statement on Preoperative Imaging for Thyroid Cancer Surgery

    PubMed Central

    Bauer, Andrew J.; Bernet, Victor A.; Ferris, Robert L.; Loevner, Laurie A.; Mandel, Susan J.; Orloff, Lisa A.; Randolph, Gregory W.; Steward, David L.

    2015-01-01

    Background: The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Summary: Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging. PMID:25188202

  8. Effectiveness of ultrasound-guided transversus abdominis plane block and rectus sheath block in pain control and recovery after gynecological transumbilical single-incision laparoscopic surgery.

    PubMed

    Mugita, M; Kawahara, R; Tamai, Y; Yamasaki, K; Okuno, S; Hanada, R; Inaoka, M; Funato, T

    2014-01-01

    To evaluate the effectiveness of ultrasound-guided transversus abdominis plane (TAP) and rectus sheath (RS) blocks in pain management and recovery after gynecological single-incision laparoscopic surgery (SILS). Abilateral TAP block (Group A, n = 9), bilateral TAP and RS blocks (Group B, n = 10), and a bilateral RS block (Group C, n = 9) with 40 ml ropivacaine per patient were conducted in 28 patients undergoing SILS for ovarian tumors. A pain score and walking distance in a 6-minute walk test (6MWT) were examined. Pain scores were significantly lower on postoperative day (POD) 3 than on POD 1 in Groups B (p = 0.03) and C (p = 0.02). The walking distance on POD 3 was comparable with that before surgery in Group C (p = 0.75), but shorter in Groups A (p = 0.004) and B (p = 0.02). The RS block alone was the most effective in relieving pain and accelerating general recovery after gynecological SILS.

  9. SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ellens, N; Farahani, K

    2015-06-15

    Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precisionmore » of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for

  10. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  11. Reality named endoscopic ultrasound biliary drainage

    PubMed Central

    Guedes, Hugo Gonçalo; Lopes, Roberto Iglesias; de Oliveira, Joel Fernandez; Artifon, Everson Luiz de Almeida

    2015-01-01

    Endoscopic ultrasound (EUS) is used for diagnosis and evaluation of many diseases of the gastrointestinal (GI) tract. In the past, it was used to guide a cholangiography, but nowadays it emerges as a powerful therapeutic tool in biliary drainage. The aims of this review are: outline the rationale for endoscopic ultrasound-guided biliary drainage (EGBD); detail the procedural technique; evaluate the clinical outcomes and limitations of the method; and provide recommendations for the practicing clinician. In cases of failed endoscopic retrograde cholangiopancreatography (ERCP), patients are usually referred for either percutaneous transhepatic biliary drainage (PTBD) or surgical bypass. Both these procedures have high rates of undesirable complications. EGBD is an attractive alternative to PTBD or surgery when ERCP fails. EGBD can be performed at two locations: transhepatic or extrahepatic, and the stent can be inserted in an antegrade or retrograde fashion. The drainage route can be transluminal, duodenal or transpapillary, which, again, can be antegrade or retrograde [rendezvous (EUS-RV)]. Complications of all techniques combined include pneumoperitoneum, bleeding, bile leak/peritonitis and cholangitis. We recommend EGBD when bile duct access is not possible because of failed cannulation, altered upper GI tract anatomy, gastric outlet obstruction, a distorted ampulla or a periampullary diverticulum, as a minimally invasive alternative to surgery or radiology. PMID:26504507

  12. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    PubMed

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  13. Comparison of transcutaneous contrast-enhanced ultrasound-guided injected hemostatic agents with traditional surgery treatment for liver, spleen and kidney trauma: a retrospective study.

    PubMed

    Wang, Dong; Lv, Faqin; Luo, Yukun; An, Lichun; Li, Junlai; Xie, Xia; Tian, Jiangke; Zhao, Weiyan; Tang, Jie

    2012-10-01

    There is lack of studies on the effectiveness of transcutaneous contrast-enhanced ultrasound-guided injections of hemostatic agents for liver. spleen and kidney trauma. We compared treatment by hemostatic agents to surgical treatment in a retrospective interventional human study. The study enrolled a total of 135 subjects from emergency unit of the Chinese People's Liberation Army General Hospital in Beijing. Within the cohort, 62 patients received contrast enhanced ultrasound-guided injection of hemostatic agents and the rest received surgical treatments. The injury severity score was lower in the hemostatic agent treatment group than surgical treatment group (p<0.05), but Glasgow coma scale scores did not reach statistical significance. The patients in the surgical treatment group had significantly higher hospital fees than those in the hemostatic treatment group (p<0.05), although the length of hospitalization did not significantly differ between two groups. Safety outcome variables pre- and post-treatment remained within normal limits in both groups. Hemostatic agents were more cost-effective than surgery to treat patients with liver, spleen and kidney trauma. However, given the limited sample size, subsequent studies drawing upon larger populations from multiple medical centers are necessary for follow-up.

  14. Applications for a hybrid operating room in thoracic surgery: from multidisciplinary procedures to ­­image-guided video-assisted thoracoscopic surgery

    PubMed Central

    Terra, Ricardo Mingarini; Andrade, Juliano Ribeiro; Mariani, Alessandro Wasum; Garcia, Rodrigo Gobbo; Succi, Jose Ernesto; Soares, Andrey; Zimmer, Paulo Marcelo

    2016-01-01

    ABSTRACT The concept of a hybrid operating room represents the union of a high-complexity surgical apparatus with state-of-the-art radiological tools (ultrasound, CT, fluoroscopy, or magnetic resonance imaging), in order to perform highly effective, minimally invasive procedures. Although the use of a hybrid operating room is well established in specialties such as neurosurgery and cardiovascular surgery, it has rarely been explored in thoracic surgery. Our objective was to discuss the possible applications of this technology in thoracic surgery, through the reporting of three cases. PMID:27812640

  15. Ultrasound pregnancy

    MedlinePlus

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; Placenta previa - ultrasound; Multiple pregnancy - ultrasound; ...

  16. Ethical challenges in fetal surgery.

    PubMed

    Smajdor, Anna

    2011-02-01

    Fetal surgery has been practised for some decades now. However, it remains a highly complex area, both medically and ethically. This paper shows how the routine use of ultrasound has been a catalyst for fetal surgery, in creating new needs and new incentives for intervention. Some of the needs met by fetal surgery are those of parents and clinicians who experience stress while waiting for the birth of a fetus with known anomalies. The paper suggests that the role of technology and visualisation techniques in creating and meeting such new needs is ethically problematic. It then addresses the idea that fetal surgery should be restricted to interventions that are life-saving for the fetus, arguing that this restriction is unduly paternalistic. Fetal surgery poses challenges for an autonomy-based system of ethics. However, it is risky to circumvent these challenges by restricting the choices open to pregnant women, even when these choices appear excessively altruistic.

  17. Clinical Application of High-intensity Focused Ultrasound in Cancer Therapy

    PubMed Central

    Hsiao, Yi-Hsuan; Kuo, Shou-Jen; Tsai, Horng-Der; Chou, Ming-Chih; Yeh, Guang-Perng

    2016-01-01

    The treatment of cancer is an important issue in both developing and developed countries. Clinical use of ultrasound in cancer is not only for the diagnosis but also for the treatment. Focused ultrasound surgery (FUS) is a noninvasive technique. By using the combination of high-intensity focused ultrasound (HIFU) and imaging method, FUS has the potential to ablate tumor lesions precisely. The main mechanisms of HIFU ablation involve mechanical and thermal effects. Recent advances in HIFU have increased its popularity. Some promising results were achieved in managing various malignancies, including pancreas, prostate, liver, kidney, breast and bone. Other applications include brain tumor ablation and disruption of the blood-brain barrier. We aim at briefly outlining the clinical utility of FUS as a noninvasive technique for a variety of types of cancer treatment. PMID:26918034

  18. Levator hiatal area as a risk factor for cystocele recurrence after surgery: a prospective study.

    PubMed

    Vergeldt, T F M; Notten, K J B; Weemhoff, M; van Kuijk, S M J; Mulder, F E M; Beets-Tan, R G; Vliegen, R F A; Gondrie, E T C M; Bergmans, M G M; Roovers, J P W R; Kluivers, K B

    2015-07-01

    To investigate whether increased levator hiatal area, measured preoperatively, was independently associated with anatom-ical cystocele recurrence 12 months after anterior colporrhaphy. Multicentre prospective cohort study. Nine teaching hospitals in the Netherlands. Women planned for conventional anterior colporrhaphy without mesh. Women underwent physical examination, translabial three-dimensional (3D) ultrasound and magnetic resonance imaging (MRI) prior to surgery. At 12 months after surgery the physical examination was repeated. Women with and without anatomical cystocele recurrence were compared to assess the association with levator hiatal area on 3D ultrasound, levator hiatal area on MRI, and potential confounding factors. The receiver operating characteristic (ROC) curve was created to quantify the discriminative ability of using levator hiatal area to predict anatomical cystocele recurrence. Of 139 included women, 76 (54.7%) had anatomical cystocele recurrence. Preoperative stage 3 or 4 and increased levator hiatal area during Valsalva on ultrasound were significantly associated with cystocele recurrence, with odds ratios of 3.47 (95% confidence interval, 95% CI 1.66-7.28) and 1.06 (95% CI 1.01-1.11) respectively. The area under the ROC curve was 0.60 (95% CI 0.51-0.70) for levator hiatal area during Valsalva on ultrasound, and 0.65 (95% CI 0.55-0.71) for preoperative Pelvic Organ Prolapse Quantification (POP-Q) stage. Increased levator hiatal area during Valsalva on ultrasound prior to surgery and preoperative stage 3 or 4 are independent risk factors for anatomical cystocele recurrence after anterior colporrhaphy; however, increased levator hiatal area as the sole factor for predicting anatomical cystocele recurrence after surgery shows poor test characteristics. © 2015 Royal College of Obstetricians and Gynaecologists.

  19. Diaphragm-Sparing Nerve Blocks for Shoulder Surgery.

    PubMed

    Tran, De Q H; Elgueta, Maria Francisca; Aliste, Julian; Finlayson, Roderick J

    Shoulder surgery can result in significant postoperative pain. Interscalene brachial plexus blocks (ISBs) constitute the current criterion standard for analgesia but may be contraindicated in patients with pulmonary pathology due to the inherent risk of phrenic nerve block and symptomatic hemidiaphragmatic paralysis. Although ultrasound-guided ISB with small volumes (5 mL), dilute local anesthetic (LA) concentrations, and LA injection 4 mm lateral to the brachial plexus have been shown to reduce the risk of phrenic nerve block, no single intervention can decrease its incidence below 20%. Ultrasound-guided supraclavicular blocks with LA injection posterolateral to the brachial plexus may anesthetize the shoulder without incidental diaphragmatic dysfunction, but further confirmatory trials are required. Ultrasound-guided C7 root blocks also seem to offer an attractive, diaphragm-sparing alternative to ISB. However, additional large-scale studies are needed to confirm their efficacy and to quantify the risk of periforaminal vascular breach. Combined axillary-suprascapular nerve blocks may provide adequate postoperative analgesia for minor shoulder surgery but do not compare favorably to ISB for major surgical procedures. One intriguing solution lies in the combined use of infraclavicular brachial plexus blocks and suprascapular nerve blocks. Theoretically, the infraclavicular approach targets the posterior and lateral cords, thus anesthetizing the axillary nerve (which supplies the anterior and posterior shoulder joint), as well as the subscapular and lateral pectoral nerves (both of which supply the anterior shoulder joint), whereas the suprascapular nerve block anesthetizes the posterior shoulder. Future randomized trials are required to validate the efficacy of combined infraclavicular-suprascapular blocks for shoulder surgery.

  20. Interventional multi-spectral photoacoustic imaging in laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Hill, Emma R.; Xia, Wenfeng; Nikitichev, Daniil I.; Gurusamy, Kurinchi; Beard, Paul C.; Hawkes, David J.; Davidson, Brian R.; Desjardins, Adrien E.

    2016-03-01

    Laparoscopic procedures can be an attractive treatment option for liver resection, with a shortened hospital stay and reduced morbidity compared to open surgery. One of the central challenges of this technique is visualisation of concealed structures within the liver, particularly the vasculature and tumourous tissue. As photoacoustic (PA) imaging can provide contrast for haemoglobin in real time, it may be well suited to guiding laparoscopic procedures in order to avoid inadvertent trauma to vascular structures. In this study, a clinical laparoscopic ultrasound probe was used to receive ultrasound for PA imaging and to obtain co-registered B-mode ultrasound (US) images. Pulsed excitation light was delivered to the tissue via a fibre bundle in dark-field mode. Monte Carlo simulations were performed to optimise the light delivery geometry for imaging targets at depths of 1 cm, 2 cm and 3 cm, and 3D-printed mounts were used to position the fibre bundle relative to the transducer according to the simulation results. The performance of the photoacoustic laparoscope system was evaluated with phantoms and tissue models. The clinical potential of hybrid PA/US imaging to improve the guidance of laparoscopic surgery is discussed.

  1. Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract.

    PubMed

    Fakhry, Mohamed A; El Shazly, Malak I

    2011-01-01

    To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre- and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3). Improvement in BCVA was statistically significant in both groups (P < 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P < 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P < 0.001). Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used.

  2. Non-ionizing real-time ultrasonography in implant and oral surgery: A feasibility study.

    PubMed

    Chan, Hsun-Liang; Wang, Hom-Lay; Fowlkes, Jeffery Brian; Giannobile, William V; Kripfgans, Oliver D

    2017-03-01

    Ultrasound imaging has potential to complement radiographic imaging modalities in implant and oral surgery given that it is non-ionizing and provides instantaneous images of anatomical structures. For application in oral and dental imaging, its qualities are dependent on its ability to accurately capture these complex structures. Therefore, the aim of this feasibility study was to investigate ultrasound to image soft tissue, hard tissue surface topography and specific vital structures. A clinical ultrasound scanner, paired with two 14-MHz transducers of different sizes (one for extraoral and the other for intraoral scans), was used to scan the following structures on a fresh cadaver: (i) the facial bone surface and soft tissue of maxillary anterior teeth, (ii) the greater palatine foramen; (iii) the mental foramen and (iv) the lingual nerve. Multiple measurements relevant to these structures were made on the ultrasound images and compared to those on cone-beam computed tomography (CBCT) scans and/or direct measurements. Ultrasound imaging could delineate hard tissue surfaces, including enamel, root dentin and bone as well as soft tissue with high resolution (110 μm wavelength). The greater palatine foramen, mental foramen and lingual nerve were clearly shown in ultrasound images. Merging ultrasound and CBCT images demonstrated overall spatial accuracy of ultrasound images, which was corroborated by data gathered from direct measurements. For the first time, this study provides proof-of-concept evidence that ultrasound can be a real-time and non-invasive alternative for the evaluation of oral and dental anatomical structures relevant for implant and oral surgery. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Experimental validation of A-mode ultrasound acquisition system for computer assisted orthopaedic surgery

    NASA Astrophysics Data System (ADS)

    De Lorenzo, Danilo; De Momi, Elena; Beretta, Elisa; Cerveri, Pietro; Perona, Franco; Ferrigno, Giancarlo

    2009-02-01

    Computer Assisted Orthopaedic Surgery (CAOS) systems improve the results and the standardization of surgical interventions. Anatomical landmarks and bone surface detection is straightforward to either register the surgical space with the pre-operative imaging space and to compute biomechanical parameters for prosthesis alignment. Surface points acquisition increases the intervention invasiveness and can be influenced by the soft tissue layer interposition (7-15mm localization errors). This study is aimed at evaluating the accuracy of a custom-made A-mode ultrasound (US) system for non invasive detection of anatomical landmarks and surfaces. A-mode solutions eliminate the necessity of US images segmentation, offers real-time signal processing and requires less invasive equipment. The system consists in a single transducer US probe optically tracked, a pulser/receiver and an FPGA-based board, which is responsible for logic control command generation and for real-time signal processing and three custom-made board (signal acquisition, blanking and synchronization). We propose a new calibration method of the US system. The experimental validation was then performed measuring the length of known-shape polymethylmethacrylate boxes filled with pure water and acquiring bone surface points on a bovine bone phantom covered with soft-tissue mimicking materials. Measurement errors were computed through MR and CT images acquisitions of the phantom. Points acquisition on bone surface with the US system demonstrated lower errors (1.2mm) than standard pointer acquisition (4.2mm).

  4. Transvaginal ultrasound

    MedlinePlus

    Endovaginal ultrasound; Ultrasound - transvaginal; Fibroids - transvaginal ultrasound; Vaginal bleeding - transvaginal ultrasound; Uterine bleeding - transvaginal ultrasound; Menstrual bleeding - transvaginal ultrasound; ...

  5. Three-dimensional ultrasound imaging of the prostate

    NASA Astrophysics Data System (ADS)

    Fenster, Aaron; Downey, Donal B.

    1999-05-01

    Ultrasonography, a widely used imaging modality for the diagnosis and staging of many diseases, is an important cost- effective technique, however, technical improvements are necessary to realize its full potential. Two-dimensional viewing of 3D anatomy, using conventional ultrasonography, limits our ability to quantify and visualize most diseases, causing, in part, the reported variability in diagnosis and ultrasound guided therapy and surgery. This occurs because conventional ultrasound images are 2D, yet the anatomy is 3D; hence the diagnostician must integrate multiple images in his mind. This practice is inefficient, and may lead to operator variability and incorrect diagnoses. In addition, the 2D ultrasound image represents a single thin plane at some arbitrary angle in the body. It is difficult to localize and reproduce the image plane subsequently, making conventional ultrasonography unsatisfactory for follow-up studies and for monitoring therapy. Our efforts have focused on overcoming these deficiencies by developing 3D ultrasound imaging techniques that can acquire B-mode, color Doppler and power Doppler images. An inexpensive desktop computer is used to reconstruct the information in 3D, and then is also used for interactive viewing of the 3D images. We have used 3D ultrasound images for the diagnosis of prostate cancer, carotid disease, breast cancer and liver disease and for applications in obstetrics and gynecology. In addition, we have also used 3D ultrasonography for image-guided minimally invasive therapeutic applications of the prostate such as cryotherapy and brachytherapy.

  6. Ultrasound-guided diagnosis of fractures of the distal forearm in children.

    PubMed

    Herren, C; Sobottke, R; Ringe, M J; Visel, D; Graf, M; Müller, D; Siewe, J

    2015-06-01

    Distal radius and forearm fractures are injuries that are frequently seen in trauma surgery outpatient clinics. Usually, the wrist is X-rayed in 2 planes as standard diagnostic procedure. In contrast, we evaluate in our study the accuracy of ultrasonography (US) in diagnosing these fractures. This prospective study includes the patients who presented at two trauma surgery clinics with a presumptive diagnosis of distal radius or forearm fracture between January and December 2012. After a clinical examination, US imaging of the distal forearm was first carried out on 6 standardized planes followed by radiographs of the wrist made in two planes. The age limit was set at the end of 11 years. In total, 201 patients between 4 and 11 years of age were recruited with an average age of 9.5 years at the time of the trauma. There were 104 (51.7%) fractures distributed as follows: 89 (85.9%) injuries of the distal radius, 9 (8.7%) injuries of the distal ulna, and 6 (5.8%) combined injuries (radius and ulna). Sixty-five greenstick fractures were detected. Surgery was necessary in 34 cases. Specificity and sensitivity of ultrasound diagnosis were 99.5%. Ultrasound imaging is suitable to demonstrate fractures of the distal forearm. It is a highly sensitive procedure in detecting distal forearm fractures. In our opinion, a negative result in ultrasound may reduce the need for further radiographs in children with distal forearm lesions. But in any doubtful situation the need for conventional radiographs remains. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Arthroscopic Ultrasound Assessment of Articular Cartilage in the Human Knee Joint

    PubMed Central

    Kaleva, Erna; Virén, Tuomas; Saarakkala, Simo; Sahlman, Janne; Sirola, Joonas; Puhakka, Jani; Paatela, Teemu; Kröger, Heikki; Kiviranta, Ilkka; Jurvelin, Jukka S.; Töyräs, Juha

    2011-01-01

    Objective: We tested whether an intra-articular ultrasound (IAUS) method could be used to evaluate cartilage status arthroscopically in human knee joints in vivo. Design: Seven patients undergoing arthroscopic surgery of the knee were enrolled in this study. An ultrasonic examination was conducted using the same portals as in the arthroscopic surgery. A high-frequency (40-MHz) ultrasound transducer (diameter = 1 mm) was directed to the desired location on the articular surface under arthroscopic control. In addition to ultrasound data, an IAUS video and optical video through the arthroscope were recorded. Classification of cartilage injuries according to International Cartilage Repair Society, as conducted by the orthopedic surgeon, provided reference data for comparison with the IAUS. Results: The IAUS method was successful in imaging different characteristics of the articular surfaces (e.g., intact surface, surface fibrillation, and lesions of varying depth). In some cases, also the subchondral bone and abnormal internal cartilage structure were visible in the IAUS images. Specifically, using the IAUS, a local cartilage lesion of 1 patient was found to be deeper than estimated arthroscopically. Conclusions: The IAUS method provided a novel arthroscopic method for quantitative imaging of articular cartilage lesions. The IAUS provided quantitative information about the cartilage integrity and thickness, which are not available in conventional arthroscopy. The present equipment is already approved by the Food and Drug Administration for intravascular use and might be transferred to intra-articular use. The invasiveness of the IAUS method might restrict its wider clinical use but combined with arthroscopy, ultrasonic assessment may enlarge the diagnostic potential of arthroscopic surgery. PMID:26069583

  8. Which imaging modality is most effective for identifying pseudotumours in metal-on-metal hip resurfacings requiring revision: ultrasound or MARS-MRI or both?

    PubMed

    Matharu, G S; Mansour, R; Dada, O; Ostlere, S; Pandit, H G; Murray, D W

    2016-01-01

    The aims of this study were to compare the diagnostic test characteristics of ultrasound alone, metal artefact reduction sequence MRI (MARS-MRI) alone, and ultrasound combined with MARS-MRI for identifying intra-operative pseudotumours in metal-on-metal hip resurfacing (MoMHR) patients undergoing revision surgery. This retrospective diagnostic accuracy study involved 39 patients (40 MoMHRs). The time between imaging modalities was a mean of 14.6 days (0 to 90), with imaging performed at a mean of 5.3 months (0.06 to 12) before revision. The prevalence of intra-operative pseudotumours was 82.5% (n = 33). Agreement with the intra-operative findings was 82.5% (n = 33) for ultrasound alone, 87.5% (n = 35) for MARS-MRI alone, and 92.5% (n = 37) for ultrasound and MARS-MRI combined. The diagnostic characteristics for ultrasound alone and MARS-MRI alone reached similar sensitivities (90.9% vs 93.9%) and positive predictive values (PPVs; 88.2% vs 91.2%), but higher specificities (57.1% vs 42.9%) and negative predictive values (NPVs; 66.7% vs 50.0%) were achieved with MARS-MRI. Ultrasound and MARS-MRI combined produced 100% sensitivity and 100% NPV, whilst maintaining both specificity (57.1%) and PPV (91.7%). For the identification of a pseudotumour, which was confirmed at revision surgery, agreement was substantial for ultrasound and MARS-MRI combined (κ = 0.69), moderate for MARS-MRI alone (κ = 0.54), and fair for ultrasound alone (κ = 0.36). These findings suggest that ultrasound and/or MARS-MRI have a role when assessing patients with a MoMHR, with the choice dependent on local financial constraints and the availability of ultrasound expertise. However in patients with a MoMHR who require revision, combined imaging was most effective. Combined imaging with ultrasound and MARS-MRI always identified intra-operative pseudotumours if present. Furthermore, if neither imaging modality showed a pseudotumour, one was not found intra-operatively. ©2016 The British Editorial

  9. Theranostic Gd(III)-lipid microbubbles for MRI-guided focused ultrasound surgery.

    PubMed

    Feshitan, Jameel A; Vlachos, Fotis; Sirsi, Shashank R; Konofagou, Elisa E; Borden, Mark A

    2012-01-01

    We have synthesized a biomaterial consisting of Gd(III) ions chelated to lipid-coated, size-selected microbubbles for utility in both magnetic resonance and ultrasound imaging. The macrocyclic ligand DOTA-NHS was bound to PE headgroups on the lipid shell of pre-synthesized microbubbles. Gd(III) was then chelated to DOTA on the microbubble shell. The reaction temperature was optimized to increase the rate of Gd(III) chelation while maintaining microbubble stability. ICP-OES analysis of the microbubbles determined a surface density of 7.5 × 10(5) ± 3.0 × 10(5) Gd(III)/μm(2) after chelation at 50 °C. The Gd(III)-bound microbubbles were found to be echogenic in vivo during high-frequency ultrasound imaging of the mouse kidney. The Gd(III)-bound microbubbles also were characterized by magnetic resonance imaging (MRI) at 9.4 T by a spin-echo technique and, surprisingly, both the longitudinal and transverse proton relaxation rates were found to be roughly equal to that of no-Gd(III) control microbubbles and saline. However, the relaxation rates increased significantly, and in a dose-dependent manner, after sonication was used to fragment the Gd(III)-bound microbubbles into non-gas-containing lipid bilayer remnants. The longitudinal (r(1)) and transverse (r(2)) molar relaxivities were 4.0 ± 0.4 and 120 ± 18 mM(-1)s(-1), respectively, based on Gd(III) content. The Gd(III)-bound microbubbles may find application in the measurement of cavitation events during MRI-guided focused ultrasound therapy and to track the biodistribution of shell remnants. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Ultrasound

    MedlinePlus

    ... community Home > Pregnancy > Prenatal care > Ultrasound during pregnancy Ultrasound during pregnancy E-mail to a friend Please ... you. What are some reasons for having an ultrasound? Your provider uses ultrasound to do several things, ...

  11. Aesthetic ultrasound therapy

    NASA Astrophysics Data System (ADS)

    Barthe, Peter G.; Slayton, Michael H.

    2012-10-01

    Ultrasound provides key benefits in aesthetic surgery compared to laser and RF based energy sources. We present results of research, development, pre-clinical and clinical studies, regulatory clearance and commercialization of a revolutionary non-invasive aesthetic ultrasound imaging and therapy system. Clinical applications for this platform include non-invasive face-lifts, brow-lifts, and neck-lifts achieved through fractionated treatment of the superficial musculoaponeurotic system (SMAS) and subcutaneous tissue. Treatment consists of placing a grid of micro-coagulative lesions on the order of 1 mm3 at depths in skin of 1 to 6 mm, source energy levels of 0.1 to 3 J, and spacing on the order of 1.5 mm, from 4 to 10 MHz dual-mode image/treat transducers. System details are described, as well as a regulatory pathway consisting of acoustic and bioheat simulations, source characterization (hydrophone, radiation force, and Schlieren), pre-clinical studies (porcine skin ex vivo, in vivo, and human cadaver), human safety studies (treat and resect) and efficacy trials which culminated in FDA clearance (2009) under a new device classification and world-wide usage. Clinical before and after photographs are presented which validate the clinical approach.

  12. A simulation technique for 3D MR-guided acoustic radiation force imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Payne, Allison, E-mail: apayne@ucair.med.utah.edu; Bever, Josh de; Farrer, Alexis

    2015-02-15

    Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) therapies, the in situ characterization of the focal spot location and quality is critical. MR acoustic radiation force imaging (MR-ARFI) is a technique that measures the tissue displacement caused by the radiation force exerted by the ultrasound beam. This work presents a new technique to model the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model. Methods: When a steady-state point-source force acts internally in an infinite homogeneous medium, the displacement of the material in all directions is given by the Somigliana elastostatic tensor. The radiation forcemore » field, which is caused by absorption and reflection of the incident ultrasound intensity pattern, will be spatially distributed, and the tensor formulation takes the form of a convolution of a 3D Green’s function with the force field. The dynamic accumulation of MR phase during the ultrasound pulse can be theoretically accounted for through a time-of-arrival weighting of the Green’s function. This theoretical model was evaluated experimentally in gelatin phantoms of varied stiffness (125-, 175-, and 250-bloom). The acoustic and mechanical properties of the phantoms used as parameters of the model were measured using independent techniques. Displacements at focal depths of 30- and 45-mm in the phantoms were measured by a 3D spin echo MR-ARFI segmented-EPI sequence. Results: The simulated displacements agreed with the MR-ARFI measured displacements for all bloom values and focal depths with a normalized RMS difference of 0.055 (range 0.028–0.12). The displacement magnitude decreased and the displacement pattern broadened with increased bloom value for both focal depths, as predicted by the theory. Conclusions: A new technique that models the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model theory has been rigorously validated through

  13. The relevance of ultrasound imaging of suspicious axillary lymph nodes and fine-needle aspiration biopsy in the post ACOSOG Z11 era in early breast cancer

    PubMed Central

    Vijayaraghavan, Gopal R.; Vedantham, Srinivasan; Kataoka, Milliam; DeBenedectis, Carolynn; Quinlan, Robert

    2016-01-01

    Rationale and Objective Evaluation of nodal involvement in early-stage breast cancers (T1 or T2) changed following the Z11 trial; however, not all patients meet the Z11 inclusion criteria. Hence, the relevance of ultrasound imaging of the axilla and fine-needle aspiration biopsy (FNA) in early-stage breast cancers was investigated. Materials and Methods In this single-center, retrospective study, 758 subjects had pathology-verified breast cancer diagnosis over a 3-year period, of which 128 subjects with T1/T2 breast tumors had abnormal axillary lymph nodes on ultrasound, had FNA, and proceeded to axillary surgery. Ultrasound images were reviewed and analyzed using multivariable logistic regression to identify the features predictive of positive FNA. Accuracy of FNA was quantified as the area under the receiver operating characteristic curve with axillary surgery as reference standard. Results Of 128 subjects, 61 and 65 were positive on FNA and axillary surgery, respectively. Sensitivity, specificity, positive- and negative-predictive values of FNA were 52/65 (80%), 54/63 (85.7%), 52/61(85.2%) and 54/67 (80.5%), respectively. After adjusting for neoadjuvant chemotherapy between FNA and surgery, a positive FNA was associated with higher likelihood for positive axillary surgery (odds ratio: 22.7; 95% CI: 7.2–71.3, p<0.0001), and the accuracy of FNA was 0.801 (95% CI: 0.727–0.876). Among ultrasound imaging features, cortical thickness and abnormal hilum were predictive (p<0.017) of positive FNA with accuracy of 0.817 (95% CI: 0.741–0.893). Conclusion Ultrasound imaging and FNA can play an important role in the management of early breast cancers even in the post-Z11 era. Higher weightage can be accorded to cortical thickness and hilum during ultrasound evaluation. PMID:27916595

  14. Skull registration for prone patient position using tracked ultrasound

    NASA Astrophysics Data System (ADS)

    Underwood, Grace; Ungi, Tamas; Baum, Zachary; Lasso, Andras; Kronreif, Gernot; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Tracked navigation has become prevalent in neurosurgery. Problems with registration of a patient and a preoperative image arise when the patient is in a prone position. Surfaces accessible to optical tracking on the back of the head are unreliable for registration. We investigated the accuracy of surface-based registration using points accessible through tracked ultrasound. Using ultrasound allows access to bone surfaces that are not available through optical tracking. Tracked ultrasound could eliminate the need to work (i) under the table for registration and (ii) adjust the tracker between surgery and registration. In addition, tracked ultrasound could provide a non-invasive method in comparison to an alternative method of registration involving screw implantation. METHODS: A phantom study was performed to test the feasibility of tracked ultrasound for registration. An initial registration was performed to partially align the pre-operative computer tomography data and skull phantom. The initial registration was performed by an anatomical landmark registration. Surface points accessible by tracked ultrasound were collected and used to perform an Iterative Closest Point Algorithm. RESULTS: When the surface registration was compared to a ground truth landmark registration, the average TRE was found to be 1.6+/-0.1mm and the average distance of points off the skull surface was 0.6+/-0.1mm. CONCLUSION: The use of tracked ultrasound is feasible for registration of patients in prone position and eliminates the need to perform registration under the table. The translational component of error found was minimal. Therefore, the amount of TRE in registration is due to a rotational component of error.

  15. [Femtosecond laser in cataract surgery. A critical appraisal].

    PubMed

    Menapace, R M; Dick, H B

    2014-01-01

    The use of femtosecond lasers (FSL) is increasingly spreading in cataract surgery. Potential advantages over standard manual cataract surgery are the superior precision of corneal incisions and capsular openings as well as the reduction of ultrasound energy for lens nucleus work-up. Exact positioning and dimensioning of the anterior capsular opening should help reduce decentration and tilt of the intraocular lens (IOL) optics and thus achieve better target refraction. Together with the possibility to correct low-grade corneal astigmatism by precise arcuate incision, FSL technology is expected to convert cataract surgery from a purely curative into a refractive procedure. Apart from own experiences this review article critically analyses the pertinent literature published so far as well as congress presentations and personal reports of other FSL surgeons. The advantages and disadvantages are scrutinized with regard to their impact on the surgical and refractive results and compared with those experienced by the authors with manual cataract surgery over several decades. Economic and healthcare political aspects are also addressed. The use of FSL surgery improves the precision and reproducibility of corneal incisions and the capsular opening and reduces the amount of ultrasound energy required for lens nucleus work-up. However, the clinical benefits must be put into perspective due to the subsequent surgical manipulation of the incisions (during lens emulsification, aspiration and IOL injection), the lacking possibility to visualize the crystalline lens equator as the reference for correct capsulotomy centration and the relativity of ultrasound energy consumption on the corneal endothelial trauma. This is of particular relevance against the background of the significantly higher costs. Conversely, tears of the anterior capsule edge which, apart from interfering with correct IOL positioning, may entail serious complications presently occur more frequently with all FSL

  16. A dual-mode hemispherical sparse array for 3D passive acoustic mapping and skull localization within a clinical MRI guided focused ultrasound device

    NASA Astrophysics Data System (ADS)

    Crake, Calum; Brinker, Spencer T.; Coviello, Christian M.; Livingstone, Margaret S.; McDannold, Nathan J.

    2018-03-01

    Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, past implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound (MRgFUS) devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5  ×  0.4 mm piezoceramic disc elements arranged in pseudorandom fashion on a low-profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for detection of cavitation and 3D passive acoustic imaging. In active mode, the array was able to perform B-mode imaging of a human skull, showing the outer skull surface with good qualitative agreement with MR imaging. Extension to 3D showed the array was able to locate the skull within  ±2 mm/2° of reference points derived from MRI, which could potentially allow registration of a patient to the therapy system without the expense of real-time MRI. In passive mode, the array was able to resolve a point source in 3D within a  ±10 mm region about each axis from the focus, detect cavitation (SNR ~ 12 dB) at burst lengths from 10 cycles to continuous wave, and produce 3D acoustic maps in a flow phantom. Finally, the array was used to detect and map cavitation associated with microbubble activity in the brain in nonhuman primates.

  17. Assessment of Curve Flexibility on Scoliotic Surgical Candidates Using Ultrasound Imaging Method.

    PubMed

    Zheng, Rui; Hill, Doug; Hedden, Douglas; Moreau, Marc; Le, Lawrence H; Raso, Jim; Lou, Edmond

    2017-05-01

    The ultrasound imaging method was implemented to assess the spinal curve flexibility of scoliotic surgical candidates, or how much correction it can achieve while patients are bending or lying down. Fifteen participants were recruited. Pre-operative radiographs and ultrasound images in both standing and bending positions were acquired. The post-operative standing radiographs were obtained 1 wk after surgery. Two raters (RZ, EL) measured the ultrasound images twice, 1 wk apart. A curve correction index (C I ) was developed to estimate the curve flexibility. The C I from the pre-operative bending radiograph, ultrasound and post-operative radiograph were 0.51 ± 0.18; R1: 0.74 ± 0.08 vs R2: 0.72 ± 0.09 and 0.60 ± 0.10, respectively. The correlation of C I between ultrasound and post-operative radiography was slightly higher than the pre-operative bending and post-operative radiography. This pilot study demonstrated the bending ultrasound method is a promising supplemental tool to assess curve flexibility before surgical intervention for scoliotic surgical candidates. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Intraoperative Functional Ultrasound Imaging of Human Brain Activity.

    PubMed

    Imbault, Marion; Chauvet, Dorian; Gennisson, Jean-Luc; Capelle, Laurent; Tanter, Mickael

    2017-08-04

    The functional mapping of brain activity is essential to perform optimal glioma surgery and to minimize the risk of postoperative deficits. We introduce a new, portable neuroimaging modality of the human brain based on functional ultrasound (fUS) for deep functional cortical mapping. Using plane-wave transmissions at an ultrafast frame rate (1 kHz), fUS is performed during surgery to measure transient changes in cerebral blood volume with a high spatiotemporal resolution (250 µm, 1 ms). fUS identifies, maps and differentiates regions of brain activation during task-evoked cortical responses within the depth of a sulcus in both awake and anaesthetized patients.

  19. Tissue glue in sutureless vitreoretinal surgery for the treatment of wound leakage.

    PubMed

    Batman, Cosar; Ozdamar, Yasemin; Aslan, Ozlem; Sonmez, Kenan; Mutevelli, Seda; Zilelioglu, Guler

    2008-01-01

    To assess the surgical outcomes of the use of tissue glue to close sclerotomy sites when required and the views of ultrasound biomicroscopy of the sclerotomy sites in 23- and 25-gauge vitrectomy systems. A 25-gauge transconjunctival sutureless vitrectomy was performed in 38 eyes and a 23-gauge transconjunctival sutureless vitrectomy was performed in 46 eyes for various vitreoretinal diseases. Wound leakage occurred at the sclerotomy sites at the end of the surgery in 6 eyes with 23-gauge transconjunctival sutureless vitrectomy and 7 eyes with 25-gauge transconjunctival sutureless vitrectomy. The sclerotomy sites were closed by using tissue glue to prevent wound leakage and evaluated with ultrasound biomicroscopy postoperatively. No wound leakage was observed at the end of the surgical procedure or during the follow-up period. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of ultrasound biomicroscopy. The results demonstrated the efficacy of tissue glue for closing site ports when wound leakage is observed in transconjunctival sutureless vitreoretinal surgery.

  20. [Efficiency of bupivacaine and association with dexmedetomidine in transversus abdominis plane block ultrasound guided in postoperative pain of abdominal surgery].

    PubMed

    Aksu, Recep; Patmano, Gülçin; Biçer, Cihangir; Emek, Ertan; Çoruh, Aliye Esmaoğlu

    We aimed to evaluate the effect of bupivacaine and dexmedetomidine added to bupivacaine used in tranversus abdominis plane (TAP) block on postoperative pain and patient satisfaction in patients undergoing lower abdominal surgery. Patients submitted to lower abdominal surgery were enrolled in the study. After anesthesia induction, ultrasound guided TAP block was performed. TAP block was obtained with 21mL 0.9% saline in Group C (n=31), 20mL 0.5% bupivacaine+1mL saline in Group B (n=31), and 20mL 0.5% bupivacaine+1mL dexmedetomidine (100μg) in Group BD (n=31). Visual analog scale scores were lower in Group BD compared to Group C, at all time points (p<0.05); it was lower in group BD than in group B at 10-24h. In Group B, it was lower than Group C at 2-8h (p<0.05). Total morphine consumption was lower in Group BD compared to other groups and lower in group B than in the controls (p<0.001). Patient satisfaction was higher in Group BD than in other groups and was higher in both study groups than in the controls (p<0.001). Nausea-vomiting scores, antiemetic requirement, or additional analgesic administration were not significant among groups (p>0.05). The addition of dexmedetomidine to bupivacaine on TAP block decreased postoperative pain scores and morphine consumption; it also increased patient satisfaction in patients undergoing lower abdominal surgery. Dexmedetomidine did not have any effect on nausea and vomiting score and antiemetic requirement. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  1. Ultrasound-guided rectus sheath and transversus abdominis plane blocks for perioperative analgesia in upper abdominal surgery: A randomized controlled study.

    PubMed

    Abdelsalam, Khaled; Mohamdin, O W

    2016-01-01

    Regional anesthetic techniques can be used to alleviate postoperative pain in patients undergoing major upper abdominal surgery. Our aim was to evaluate the efficacy of bilateral ultrasound (US)-guided rectus sheath (RS) and transversus abdominis plane (TAP) blocks for better perioperative analgesia. It is a prospective, observer-blinded, randomized clinical study. 40 eligible patients undergoing elective liver resection or Whipple procedure were included. All patients received a standardized anesthetic technique. Group 1 (n = 20) received preincisional US-guided bilateral RS and TAP blocks using 20 ml volume of bupivacaine 0.25% for each, and group 2 (n = 20) received local wound infiltration at end of surgery with 40 ml of bupivacaine 0.25%. A standardized postoperative analgesic regimen composed of intravenous paracetamol and a morphine patient-controlled analgesia (PCA). The use of intraoperative fentanyl and recovery room morphine boluses, PCA-administered morphine, pain scores as well as number of patients' experienced postoperative nausea and vomiting in the ward at 6 and 24 h were recorded. Group 1 patients received a significantly lower cumulative intraoperative fentanyl, significantly lesser boluses of morphine in postanesthesia care unit, as well, significantly lower cumulative 24 h postoperative morphine dosage than the group 2 patients. Pain visual analog scale scores were significantly lower at both 6 and 24 h postoperatively in TAP group when compared with the no-TAP group. There were no complications related to the TAP block procedures. No signs or symptoms of local anesthetic systemic toxicity were detected. The combination of bilateral US-guided RS and TAP blocks provides excellent perioperative analgesia for major upper abdominal surgery.

  2. Duplex ultrasound

    MedlinePlus

    Vascular ultrasound; Peripheral vascular ultrasound ... A duplex ultrasound combines: Traditional ultrasound: This uses sound waves that bounce off blood vessels to create pictures. Doppler ultrasound: This ...

  3. Localized Ablation of Thyroid Tissue by High-Intensity Focused Ultrasound: an Alternative to Surgery?

    NASA Astrophysics Data System (ADS)

    Esnault, Olivier; Franc, Brigitte; Chapelon, Jean-Yves; Lacoste, Francois

    2006-05-01

    PURPOSE: The aim of this study was to evaluate the feasibility of using a High-intensity focused ultrasound (HIFU) device to obtain a localised destruction of the thyroid with no damage to adjacent tissues. MATERIALS AND METHODS: The ewe model was used because its thyroid gland is easily accessible with ultrasound. The animals were anaesthetised with 10 mg / kg IV injection of Penthothal. The HIFU pulses were generated by a 3-MHz spherical transducer under ultrasound guidance. Macroscopic and microscopic tissue lesions were identified after formalin fixation of the anterior part of the ewe's neck. RESULTS: After determining the optimal instrument settings to obtain localized thyroid ablation, the repeatability of the method was evaluated using a HIFU prototype designed specifically for human use: in 13 ewes (26 treated lobes), an average of 20 (range: 14-27) ultrasound pulses (pulse duration: 3 s) per lobe covering a mean volume of 0.5 cm3 (range: 0.3-0.7 cm3) were delivered. The ewes were sacrificed 2-5 weeks after treatment delivery. No damage to the nerves, trachea, esophagus or muscle was observed. Only 3 ewes suffered superficial skin burns. The desired thyroid lesions were obtained in 25/26 treated lobes, as demonstrated by fibrotic tissues, which replaced necrotic areas. CONCLUSION: These results obtained in the ewe model show that thyroid lesions of defined volume can be induced safely and suggest that the HIFU device is now ready for human trials.

  4. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    PubMed Central

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  5. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. WE-H-209-01: Advances in Ultrasound Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hynynen, K.

    Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives:more » Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.« less

  7. The Value of Ultrasound Monitoring of Adnexal Masses for Early Detection of Ovarian Cancer

    PubMed Central

    Suh-Burgmann, Elizabeth; Kinney, Walter

    2016-01-01

    Although ultrasound has so far been found to be ineffective as a screening tool for ovarian cancer, it is commonly used as a means of evaluating or following ovarian or adnexal masses once they are detected. We review the use of serial ultrasound for the management of adnexal masses and propose an approach to monitoring based on an understanding of the overall risk of cancer among the population in question and an assessment of how the potential benefit of monitoring compares with potential risk. In our approach, masses that are symptomatic, large (>10 cm), associated with an elevated CA 125 level or overt signs of malignancy, or that are determined to have a worrisome appearance by stringent ultrasound criteria should be evaluated surgically. Women with masses that have none of these characteristics should be offered monitoring. Short-term initial ultrasound monitoring carries significant potential benefit in terms of aiding detection of early malignancy and avoidance of unnecessary surgery. However, if a mass remains stable but persistent, the potential benefit of ongoing monitoring wanes with time, whereas the potential harms, in terms of patient anxiety, cost, and the risk of incidental findings and unnecessary surgery increase. Therefore, monitoring of stable lesions should be limited in duration in order to limit potential harms from overtreatment and overdiagnosis. PMID:26904503

  8. Three dimensional ultrasound and hdlive technology as possible tools in teaching embryology.

    PubMed

    Popovici, Razvan; Pristavu, Anda; Sava, Anca

    2017-10-01

    Embryology is an important subject in order to gain an understanding of medicine and surgery; however, sometimes students find the subject difficult to grasp and apply to clinical practice. Modern imaging techniques can be useful aids in teaching and understanding embryology. Imaging techniques have very rapidly evolved over the last few years, advancing from two- to three-dimensional (3D) ultrasound. HDlive is an innovative ultrasound technique that generates near-realistic images of the human fetus. In order to evince the capabilities of 3D ultrasound and HDlive technology in teaching embryology, we evaluated using this technique the normal evolution of the embryo and fetus from the fifth to eleventh week of amenorrhea. Our conclusion is that by yielding clear and impressive images, 3D ultrasound and HDlive could be useful tools in teaching embryology to medical students. Clin. Anat. 30:953-957, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  9. Tuberculosis and the pancreas: a diagnostic challenge solved by endoscopic ultrasound. A case series.

    PubMed

    Chatterjee, Suvadip; Schmid, Matthias L; Anderson, Kirsty; Oppong, Kofi W

    2012-03-01

    Pancreatic tuberculosis is a rare disease. It can be easily confused with malignancy or pancreatitis on imaging. This could result in unnecessary surgery. As this is a treatable disease it is imperative to diagnose this condition pre-operatively. We report three cases of pancreatic tuberculosis that were diagnosed by endoscopic ultrasound. In conclusion, endoscopic ultrasound is the diagnostic modality of choice for pancreatic tuberculosis facilitating high resolution imaging, as well as sampling of tissue for staining, cytology, culture and polymerase chain reaction assay.

  10. High-intensity focused ultrasound ablation of thyroid nodules: first human feasibility study.

    PubMed

    Esnault, Olivier; Franc, Brigitte; Ménégaux, Fabrice; Rouxel, Agnès; De Kerviler, Eric; Bourrier, Pierre; Lacoste, François; Chapelon, Jean-Yves; Leenhardt, Laurence

    2011-09-01

    Thyroid surgery is common, but complications may occur. High-intensity focused ultrasound (HIFU) is a minimally invasive alternative to surgery. We hypothesized that an optimized HIFU device could be safe and effective for ablating benign thyroid nodules without affecting neighboring structures. In this open, single-center feasibility study, 25 patients were treated with HIFU with real-time ultrasound imaging 2 weeks before a scheduled thyroidectomy for multinodular goiter. Thyroid ultrasonography imaging, thyroid function, were evaluated before and after treatment. Adverse events were carefully recorded. Each patient received HIFU for one thyroid nodule, solid or mixed, with mean diameter ≥8 mm, and no suspicion of malignancy. The HIFU device was progressively adjusted with stepwise testing. The energy level for ablation ranged from 35 to 94 J/pulse for different groups of patients. One pathologist examined all removed thyroids. Three patients discontinued treatment due to pain or skin microblister. Among the remaining 22 patients, 16 showed significant changes by ultrasound. Macroscopic and histological examinations showed that all lesions were confined to the targeted nodule without affecting neighboring structures. At pathological analysis, the extent of nodule destruction ranged from 2% to 80%. Five out of 22 patients had over 20% pathological lesions unmistakably attributed to HIFU. Seventeen cases had putative lesions including nonspecific necrosis, hemorrhage, nodule detachment, cavitations, and cysts. Among these 17 cases, 12 had both ultrasound changes and cavitation at histology that may be expected for an HIFU effect. In the last three patients ablated at the highest energy level, significant ultrasound changes and complete coagulative necrosis were observed in 80%, 78%, and 58% of the targeted area, respectively. There were no major complications of ablation. This study showed the potential efficacy of HIFU for human thyroid nodule ablation

  11. Ultrasound description of Pecs II (modified Pecs I): a novel approach to breast surgery.

    PubMed

    Blanco, R; Fajardo, M; Parras Maldonado, T

    2012-11-01

    The Pecs block (pectoral nerves block) is an easy and reliable superficial block inspired by the infraclavicular block approach and the transversus abdominis plane blocks. Once the pectoralis muscles are located under the clavicle the space between the two muscles is dissected to reach the lateral pectoral and the medial pectoral nerves. The main indications are breast expanders and subpectoral prosthesis where the distension of these muscles is extremely painful. A second version of the Pecs block is described, called "modified Pecs block" or Pecs block type II. This novel approach aims to block at least the pectoral nerves, the intercostobrachial, intercostals III-IV-V-VI and the long thoracic nerve. These nerves need to be blocked to provide complete analgesia during breast surgery, and it is an alternative or a rescue block if paravertebral blocks and thoracic epidurals failed. This block has been used in our unit in the past year for the Pecs I indications described, and in addition for, tumorectomies, wide excisions, and axillary clearances. The ultrasound sequence to perform this block is shown, together with simple X-ray dye images and gadolinium MRI images to understand the spread and pathways that can explain the benefit of this novel approach. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  12. Comparison of ultrasound-guided posterior transversus abdominis plane block and lateral transversus abdominis plane block for postoperative pain management in patients undergoing cesarean section: a randomized double-blind clinical trial study.

    PubMed

    Faiz, Seyed Hamid Reza; Alebouyeh, Mahmoud Reza; Derakhshan, Pooya; Imani, Farnad; Rahimzadeh, Poupak; Ghaderi Ashtiani, Maryam

    2018-01-01

    Due to the importance of pain control after abdominal surgery, several methods such as transversus abdominis plane (TAP) block are used to reduce the pain after surgery. TAP blocks can be performed using various ultrasound-guided approaches. Two important approaches to do this are ultrasound-guided lateral and posterior approaches. This study aimed to compare the two approaches of ultrasound-guided lateral and posterior TAP blocks to control pain after cesarean section. In this double-blind clinical trial study, 76 patients scheduled for elective cesarean section were selected and randomly divided into two groups of 38 and underwent spinal anesthesia. For pain management after the surgery, one group underwent lateral TAP block and the other group underwent posterior TAP block using 20cc of ropivacaine 0.2% on both sides. Pain intensity was evaluated based on Numerical Analog Scale (NAS) at rest and when coughing, 2, 4, 6, 12, 24 and 36 hours after surgery. The pain at rest in the posterior group at all hours post surgery was lower than the lateral group, especially at 6, 12 and 24 hours after the surgery and the difference was statistically significant ( p =0.03, p <0.004, p =0.001). The results of this study show that ultrasound-guided posterior TAP block compared with the lateral TAP block was more effective in pain control after cesarean section.

  13. Non-contact biomedical photoacoustic and ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Rousseau, Guy; Gauthier, Bruno; Blouin, Alain; Monchalin, Jean-Pierre

    2012-06-01

    The detection of ultrasound in photoacoustic tomography (PAT) usually relies on ultrasonic transducers in contact with the biological tissue through a coupling medium. This is a major drawback for important potential applications such as surgery. Here we report the use of a remote optical method, derived from industrial laser-ultrasonics, to detect ultrasound in tissues. This approach enables non-contact PAT (NCPAT) without exceeding laser exposure safety limits. The sensitivity of the method is based on the use of suitably shaped detection laser pulses and a confocal Fabry-Perot interferometer in differential configuration. Reliable image reconstruction is obtained by measuring remotely the surface profile of the tissue with an optical coherence tomography system. The proposed method also allows non-contact ultrasound imaging (US) by applying a second reconstruction algorithm to the data acquired for NCPAT. Endogenous and exogenous inclusions exhibiting optical and acoustic contrasts were detected ex vivo in chicken breast and calf brain specimens. Inclusions down to 0.3 mm in size were detected at depths exceeding 1 cm. The method could expand the scope of photoacoustic and US to in-vivo biomedical applications where contact is impractical.

  14. Prospective Controlled Study of Buttock Fat Transfer Using Ultrasound and Photographic Measurements

    PubMed Central

    2016-01-01

    Background: Buttock fat transfer is now the preferred method for gluteal augmentation. However, its efficacy has not been well-documented using measurements. Methods: Twenty-five consecutive patients underwent buttock fat transfer performed by the author. Twenty-one patients returned for measurements ≥3 months after surgery (inclusion rate, 84%). A separate group of 25 patients undergoing cosmetic surgery without buttock fat transfer served as controls. All patients underwent superwet liposuction using total intravenous anesthesia and no prone positioning. A closed filtration system was used to collect the fat. Subcutaneous fat thickness was assessed using ultrasound imaging. Measurements were made on standardized photographs. The data were controlled for change in body mass index. Clinical data were also evaluated. Results: The mean fat volume injected per buttock was 287 mL (range, 70–550 mL). Ultrasound measurements detected a significant increase in the subcutaneous fat thickness (P ≤ 0.001), with mean increments of 0.66 cm for the right buttock and 0.86 cm for the left buttock and no significant change for control patients. The mean calculated fat retention, based on the measured surface area injected, was 66%. Photographic measurements of buttock projection revealed a significant increase in treated patients (P < 0.01) and no significant change in control patients. There were no clinical complications at either recipient or donor sites and no evidence of oily cysts on ultrasound examinations. Conclusions: Photographic and ultrasound measurements, and clinical findings, confirm that buttock fat transfer effectively and safely increases buttock projection. PMID:27579222

  15. [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

    PubMed

    Jung, E M; Clevert, D A

    2018-06-01

    Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.

  16. Ultrasound

    MedlinePlus

    Ultrasound is a type of imaging. It uses high-frequency sound waves to look at organs and ... liver, and other organs. During pregnancy, doctors use ultrasound to view the fetus. Unlike x-rays, ultrasound ...

  17. Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract

    PubMed Central

    Fakhry, Mohamed A; Shazly, Malak I El

    2011-01-01

    Purpose To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. Settings Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. Methodology Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre- and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3). Results Improvement in BCVA was statistically significant in both groups (P < 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P < 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P < 0.001). Conclusion Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used. PMID

  18. Ultrasound-guided bilateral rectus sheath block reduces early postoperative pain after laparoscopic gynecologic surgery: a randomized study.

    PubMed

    Cho, Sooyoung; Kim, Youn Jin; Jeong, Kyungah; Moon, Hye-Sung

    2018-04-01

    Rectus sheath block (RSB) is an anterior abdominal wall block that reduces postoperative pain associated with midline incisions. This study aims to investigate the effect of ultrasound-guided bilateral RSB (US-BRSB) on postoperative pain and analgesic consumption in patients undergoing laparoscopic gynecologic surgery. Sixty patients who underwent laparoscopic gynecologic surgery were allocated to RSB (n = 30) or control (n = 30) group. A bilateral US-BRSB procedure (30 ml of 0.25% ropivacaine) was performed after induction of general anesthesia in the RSB group. The control group proceeded the surgery without sham block. All patients received fentanyl-based intravenous patient-controlled analgesia and rescue analgesics upon demand. Pain was scored by a blinded observer using a verbal numerical rating scale (VNRS) at rest while coughing at 0, 1, 6, 12, 24, and 48 h after postanesthesia care unit (PACU) admission. The primary outcome was the total number of rescue analgesics used in the 48-h postoperative period. At 0 h, VNRS were lower in the RSB group than in the control, both at rest (median VNRS 4.5 vs. 5, p = 0.02) and while coughing (median VNRS 6 vs. 7, p = 0.004). At 6 h, VNRS scores were lower in the RSB group than in the control while coughing (median VNRS 3 vs. 5, p = 0.01). Fentanyl use as rescue analgesics in the PACU was significantly lower in the RSB group than in the control (27.7 ± 32.1 vs. 53.3 ± 33.7 µg, respectively; p = 0.004). At 48 h postoperatively, the total number of rescue analgesics administered were significantly fewer in the RSB group than in the control (2.5 ± 2.5 vs. 3.9 ± 2.6, respectively; p = 0.04). US-BRSB reduces the immediate postoperative pain and opioid consumption during the early postoperative period. CLINICALTRIALS. NCT02476799, https://clinicaltrials.gov/ct2/show/NCT02476799 .

  19. Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

    PubMed

    Kolega, Marija Škara; Kovačević, Suzana; Čanović, Samir; Pavičić, Ana Didović; Bašić, Jadranka Katušić

    2015-03-01

    Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included in this prospective randomized trial. Twenty eyes underwent IOL master and 20 eyes had aplanation ultrasound biometry. There were included only eyes with age-related cataract and postoperative natural visual acuity (VA) 0.7. Visual acuity was performed 6 weeks after cataract surgery. After 6 weeks best natural visual acuity were 0.9 (± 0.1) in IOL-Master group and 0.85 (± 0.15) in ultrasound biometry. The postoperative mean absolute refractive error was 0.75 (± 0.5) D for ultrasound biometry and 0.50 (± 0.50) D for IOL-Master. Optical biometry with the IOL-Master proved to be slightly more accurate than ultrasound biometry for IOL power calculation.

  20. Vascular applications of contrast-enhanced ultrasound imaging.

    PubMed

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf G; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. High-intensity focused ultrasound for potential treatment of polycystic ovary syndrome: toward a noninvasive surgery.

    PubMed

    Shehata, Islam A; Ballard, John R; Casper, Andrew J; Hennings, Leah J; Cressman, Erik; Ebbini, Emad S

    2014-02-01

    To investigate the feasibility of using high-intensity focused ultrasound (HIFU), under dual-mode ultrasound arrays (DMUAs) guidance, to induce localized thermal damage inside ovaries without damage to the ovarian surface. Laboratory feasibility study. University-based laboratory. Ex vivo canine and bovine ovaries. DMUA-guided HIFU. Detection of ovarian damage by ultrasound imaging, gross pathology, and histology. It is feasible to induce localized thermal damage inside ovaries without damage to the ovarian surface. DMUA provided sensitive imaging feedback regarding the anatomy of the treated ovaries and the ablation process. Different ablation protocols were tested, and thermal damage within the treated ovaries was histologically characterized. The absence of damage to the ovarian surface may eliminate many of the complications linked to current laparoscopic ovarian drilling (LOD) techniques. HIFU may be used as a less traumatic tool to perform LOD. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Ultrasound

    MedlinePlus Videos and Cool Tools

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two- ... sound waves and appear dark or black. An ultrasound can supply vital information about a mother's pregnancy ...

  3. Impact of three-dimensional endoanal ultrasound on the outcome of anal fistula surgery: a prospective cohort study.

    PubMed

    Ding, J-H; Bi, L-X; Zhao, K; Feng, Y-Y; Zhu, J; Zhang, B; Yin, S-H; Zhao, Y-J

    2015-12-01

    The aim of the study was to evaluate the impact of three-dimensional endoanal ultrasound (3D-EAUS) on postoperative outcome in patients with anal fistula. This prospective study compared clinical and functional outcomes of patients with and without preoperative 3D-EAUS examination 1 year after anal fistula surgery. Patients were prospectively followed and evaluated by a standardized protocol including physical examination, the Wexner Incontinence Score (WIS) and anorectal manometry, at baseline and 1 year after surgery. A total of 196 patients were enrolled. There were no significant differences in demographic and operative parameters, except for operation time, between the two groups. At 1 year follow-up, the overall recurrence rates were 8.8% (9/102) in the 3D-EAUS group and 13.8% (13/94) in the examination under anaesthesia (EUA) group. In the subgroup of patients with complex fistulae, the recurrence rate was numerically lower in the 3D-EAUS group (12.8% vs 22.5%; P = 0.26). The WIS in the EUA group significantly worsened (0.35 ± 0.94 vs 1.07 ± 1.59; P = 0.003) with a decreased the number of fully continent patients (82.5% vs 55%; P = 0.008) while neither the WIS nor the proportion of fully continent patients changed in the 3D-EAUS group. Fewer patients in the 3D-EAUS group developed incontinence postoperatively (6.7% vs 33.3%; P = 0.012) and they had better maximum resting pressure and maximum squeeze pressure than the EUA group. Preoperative use of 3D-EAUS had a favourable impact on the outcome of surgical treatment for anal fistulae, especially in those with complex anal fistula. It should be routinely used in the clinical setting. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.

  4. Is it necessary to perform prophylactic cholecystectomy for all symptomatic gallbladder polyps diagnosed with ultrasound?

    PubMed

    Velidedeoğlu, Mehmet; Çitgez, Bülent; Arıkan, Akif Enes; Ayan, Fadıl

    2017-01-01

    The main aim of this study is to determine the necessity of cholecystectomy in patients with ultrasound diagnosed symptomatic polypoid lesions of the gallbladder. The data of 82 patients with polypoid lesions of the gallbladder who had cholecystectomy between 2000 and 2012 were analyzed retrospectively with preoperative ultrasound and histopathology results. The mean age was 48.05±11.18 years (range 25-74 years). All patients underwent preoperative ultrasound examination. Eighteen (22%) of the 82 patients were asymptomatic; their polypoid lesions of the gallbladder were detected with ultrasound during a check-up or other reasons. In 45 (55%) of cases pathology reported no polypoid lesions of the gallbladder. Right upper quadrant or epigastric pain was the most common symptom (41.46%) that led to hepatobiliary ultrasound, the other symptom was dyspepsia (36.59%). On preoperative ultrasound evaluation, 22 patients had multiple polyps, and 9 of these 22 patients had at least 3 polyps. There is an inaccuracy of ultrasound to detect polypoid lesions of the gallbladder. After diagnosing polypoid lesions of the gallbladder by using standard ultrasound, further pre-operative diagnostic tests are needed to help discriminating benign lesions from malignant ones, which may prevent unnecessary surgery regardless of symptoms.

  5. [Basic concept in computer assisted surgery].

    PubMed

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  6. Validation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound: preliminary method and results

    NASA Astrophysics Data System (ADS)

    Clements, Logan W.; Collins, Jarrod A.; Wu, Yifei; Simpson, Amber L.; Jarnagin, William R.; Miga, Michael I.

    2015-03-01

    Soft tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface based metrics and sub-surface validation has largely been performed via phantom experiments. Tracked intraoperative ultrasound (iUS) provides a means to digitize sub-surface anatomical landmarks during clinical procedures. The proposed method involves the validation of a deformation correction algorithm for open hepatic image-guided surgery systems via sub-surface targets digitized with tracked iUS. Intraoperative surface digitizations were acquired via a laser range scanner and an optically tracked stylus for the purposes of computing the physical-to-image space registration within the guidance system and for use in retrospective deformation correction. Upon completion of surface digitization, the organ was interrogated with a tracked iUS transducer where the iUS images and corresponding tracked locations were recorded. After the procedure, the clinician reviewed the iUS images to delineate contours of anatomical target features for use in the validation procedure. Mean closest point distances between the feature contours delineated in the iUS images and corresponding 3-D anatomical model generated from the preoperative tomograms were computed to quantify the extent to which the deformation correction algorithm improved registration accuracy. The preliminary results for two patients indicate that the deformation correction method resulted in a reduction in target error of approximately 50%.

  7. Optical fiber ultrasound transmitter with electrospun carbon nanotube-polymer composite

    NASA Astrophysics Data System (ADS)

    Poduval, Radhika K.; Noimark, Sacha; Colchester, Richard J.; Macdonald, Thomas J.; Parkin, Ivan P.; Desjardins, Adrien E.; Papakonstantinou, Ioannis

    2017-05-01

    All-optical ultrasound transducers are promising for imaging applications in minimally invasive surgery. In these devices, ultrasound is transmitted and received through laser modulation, and they can be readily miniaturized using optical fibers for light delivery. Here, we report optical ultrasound transmitters fabricated by electrospinning an absorbing polymer composite directly onto the end-face of optical fibers. The composite coating consisting of an aqueous dispersion of multi-walled carbon nanotubes (MWCNTs) in polyvinyl alcohol was directly electrospun onto the cleaved surface of a multimode optical fiber and subsequently dip-coated with polydimethylsiloxane (PDMS). This formed a uniform nanofibrous absorbing mesh over the optical fiber end-face wherein the constituent MWCNTs were aligned preferentially along individual nanofibers. Infiltration of the PDMS through this nanofibrous mesh onto the underlying substrate was observed and the resulting composites exhibited high optical absorption (>97%). Thickness control from 2.3 μm to 41.4 μm was obtained by varying the electrospinning time. Under laser excitation with 11 μJ pulse energy, ultrasound pressures of 1.59 MPa were achieved at 1.5 mm from the coatings. On comparing the electrospun ultrasound transmitters with a dip-coated reference fabricated using the same constituent materials and possessing identical optical absorption, a five-fold increase in the generated pressure and wider bandwidth was observed. The electrospun transmitters exhibited high optical absorption, good elastomer infiltration, and ultrasound generation capability in the range of pressures used for clinical pulse-echo imaging. All-optical ultrasound probes with such transmitters fabricated by electrospinning could be well-suited for incorporation into catheters and needles for diagnostics and therapeutic applications.

  8. Anal Sphincters Evaluation by Endoanal Ultrasound in Obstructed Defecation.

    PubMed

    Albuquerque, Andreia; Macedo, Guilherme

    2017-12-01

    To evaluate anal sphincter abnormalities detected by endoanal ultrasound in obstructed defecation due to rectocele and rectal intussusception. The retrospective analysis includes 45 patients with obstructed defecation syndrome due to rectocele and/or rectal intussusception with or without fecal incontinence, and submitted to endoanal ultrasound. Ninety-three percent (n = 42) were women (mean age of 63 ± 12 years), and 47% (n = 21) of the patients had fecal incontinence. In total, 29% (n = 13) had a previous anorectal surgery, and 93% (n = 39) of the women had a previous vaginal delivery. An isolated rectal intussusception was diagnosed in 20% (n = 9) of the patients, an isolated rectocele in 24% (n = 11), and rectal intussusception and rectocele in 56% (n = 25). Thirty-six percent of patients had anal sphincter lacerations (n = 16): 12% (n = 2) had only internal laceration, 69% (n = 11) had only external laceration, and 19% (n = 3) had both. Two patients had a thinner internal anal sphincter with 0.9 and 1.2 mm, respectively. In total, 25% of the patients without fecal incontinence had an occult anal sphincter laceration, and all were women with an external sphincter laceration in the anterior quadrant and a previous vaginal delivery. In patients with obstructed defecation and fecal incontinence, 48% had sphincter lacerations. Previous anorectal surgery was a predictor of anal sphincter laceration (odds ratio [OR] 4.8; 95% confidence interval [CI] = 1.214-18.971; P = .025), but fecal incontinence (OR 2.7; 95% CI = 0.774-9.613; P = .119) and previous vaginal delivery (OR 1.250; 95% CI = 0.104-15.011; P = .860) were not. Endoanal ultrasound should be considered in obstructed defecation with or without fecal incontinence, especially if surgical correction is planned. © 2017 by the American Institute of Ultrasound in Medicine.

  9. Core review: physician-performed ultrasound: the time has come for routine use in acute care medicine.

    PubMed

    Royse, Colin F; Canty, David J; Faris, John; Haji, Darsim L; Veltman, Michael; Royse, Alistair

    2012-11-01

    The use of ultrasound in the acute care specialties of anesthesiology, intensive care, emergency medicine, and surgery has evolved from discrete, office-based echocardiographic examinations to the real-time or point-of-care clinical assessment and interventions. "Goal-focused" transthoracic echocardiography is a limited scope (as compared with comprehensive examination) echocardiographic examination, performed by the treating clinician in acute care medical practice, and is aimed at addressing specific clinical concerns. In the future, the practice of surface ultrasound will be integrated into the everyday clinical practice as ultrasound-assisted examination and ultrasound-guided procedures. This evolution should start at the medical student level and be reinforced throughout specialist training. The key to making ultrasound available to every physician is through education programs designed to facilitate uptake, rather than to prevent access to this technology and education by specialist craft groups. There is evidence that diagnosis is improved with ultrasound examination, yet data showing change in management and improvement in patient outcome are few and an important area for future research.

  10. Portable Bladder Ultrasound

    PubMed Central

    2006-01-01

    L are considered an indication for urinary retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. The Technology Being Reviewed Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. Review Strategy To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Summary of Findings Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One

  11. Ultrasound diagnostic of mesonephric paraovarian cyst - case report

    PubMed Central

    Bohîlțea, RE; Cîrstoiu, MM; Turcan, N; Ionescu, CA

    2016-01-01

    Paraovarian cysts are a rare pathology, constituting 10-20% of the adnexal masses. The origin can be represented by paramesonephric ducts (Hydatid cysts of Morgagni), vestiges of mesonephric ducts also represented by mesothelium, or neoplastic (cystadenomas or cystadenofibromas) that are mostly benign. Borderline or malignant paraovarian tumors are encountered less often. This article presents a case of paraovarian cyst in a 37-year-old patient, with a history of 2 pregnancies, completed by cesarean. The patient sought medical attention for an asymptomatic voluminous ovarian cyst, detected in a routine ultrasound scan. Laboratory tests and tumor markers were within normal limits. Transvaginal ultrasound and color Doppler revealed a cystic adnexal mass with 10 cm transonic, smooth, homogeneous content, avascular walls with no internal papillary projections, with a “hyperechoic line” sign of delimitation from the ovarian capsule, mostly visible when the adnexa was mobilized. The diagnostic and curative laparoscopic surgery was successful, followed by a quick recovery. The histopathological exam confirmed the benignity and the origin of the paraovarian cyst. The case was discussed in the context of the literature review concerning this pathology, drawing attention to the real possibility of differentiating ovarian from paraovarian cysts by ultrasound. PMID:27974934

  12. A collimated focused ultrasound beam of high acoustic transmission and minimum diffraction achieved by using a lens with subwavelength structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Zhou; Tu, Juan; Cheng, Jianchun

    An acoustic focusing lens incorporated with periodically aligned subwavelength grooves corrugated on its spherical surface has been developed. It is demonstrated theoretically and experimentally that acoustic focusing achieved by using the lens can suppress the relative side-lobe amplitudes, enhance the focal gain, and minimize the shifting of the focus. Use of the lens coupled with a planar ultrasound transducer can generate an ultrasound beam with enhanced acoustic transmission and collimation effect, which offers the capability of improving the safety, efficiency, and accuracy of targeted surgery implemented by high intensity focused ultrasound.

  13. Office-based ultrasound screening for abdominal aortic aneurysm

    PubMed Central

    Blois, Beau

    2012-01-01

    Abstract Objective To assess the efficacy of an office-based, family physician–administered ultrasound examination to screen for abdominal aortic aneurysm (AAA). Design A prospective observational study. Consecutive patients were approached by nonphysician staff. Setting Rural family physician offices in Grand Forks and Revelstoke, BC. Participants The Canadian Society for Vascular Surgery screening recommendations for AAA were used to help select patients who were at risk of AAA. All men 65 years of age or older were included. Women 65 years of age or older were included if they were current smokers or had diabetes, hypertension, a history of coronary artery disease, or a family history of AAA. Main outcome measures A focused “quick screen,” which measured the maximal diameter of the abdominal aorta using point-of-care ultrasound technology, was performed in the office by a resident physician trained in emergency ultrasonography. Each patient was then booked for a criterion standard scan (ie, a conventional abdominal ultrasound scan performed by a technician and interpreted by a radiologist). The maximal abdominal aortic diameter measured by ultrasound in the office was compared with that measured by the criterion standard method. The time to screen each patient was recorded. Results Forty-five patients were included in data analysis; 62% of participants were men. The mean age was 73 years. The mean pairwise difference between the office-based ultrasound scan and the criterion standard scan was not statistically significant. The mean absolute difference between the 2 scans was 0.20 cm (95% CI 0.15 to 0.25 cm). Correlation between the scans was 0.81. The office-based ultrasound scan had both a sensitivity and a specificity of 100%. The mean time to screen each patient was 212 seconds (95% CI 194 to 230 seconds). Conclusion Abdominal aortic aneurysm screening can be safely performed in the office by family physicians who are trained to use point

  14. Office-based ultrasound screening for abdominal aortic aneurysm.

    PubMed

    Blois, Beau

    2012-03-01

    To assess the efficacy of an office-based, family physician–administered ultrasound examination to screen for abdominal aortic aneurysm (AAA). A prospective observational study. Consecutive patients were approached by nonphysician staff. Rural family physician offices in Grand Forks and Revelstoke, BC. The Canadian Society for Vascular Surgery screening recommendations for AAA were used to help select patients who were at risk of AAA. All men 65 years of age or older were included. Women 65 years of age or older were included if they were current smokers or had diabetes, hypertension, a history of coronary artery disease, or a family history of AAA. A focused “quick screen”, which measured the maximal diameter of the abdominal aorta using point-of-care ultrasound technology, was performed in the office by a resident physician trained in emergency ultrasonography. Each patient was then booked for a criterion standard scan (i.e., a conventional abdominal ultrasound scan performed by a technician and interpreted by a radiologist). The maximal abdominal aortic diameter measured by ultrasound in the office was compared with that measured by the criterion standard method. The time to screen each patient was recorded. Forty-five patients were included in data analysis; 62% of participants were men. The mean age was 73 years. The mean pairwise difference between the office-based ultrasound scan and the criterion standard scan was not statistically significant. The mean absolute difference between the 2 scans was 0.20 cm (95% CI 0.15 to 0.25 cm). Correlation between the scans was 0.81. The office-based ultrasound scan had both a sensitivity and a specificity of 100%. The mean time to screen each patient was 212 seconds (95% CI 194 to 230 seconds). Abdominal aortic aneurysm screening can be safely performed in the office by family physicians who are trained to use point-of- care ultrasound technology. The screening test can be completed within the time constraints of a

  15. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning.

    PubMed

    Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A

    2014-08-01

    To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Comparison of Central Corneal Thickness Between Fourier-Domain OCT, Very High-Frequency Digital Ultrasound, and Scheimpflug Imaging Systems.

    PubMed

    Yap, Timothy E; Archer, Timothy J; Gobbe, Marine; Reinstein, Dan Z

    2016-02-01

    To compare corneal thickness measurements between three imaging systems. In this retrospective study of 81 virgin and 58 post-laser refractive surgery corneas, central and minimum corneal thickness were measured using optical coherence tomography (OCT), very high-frequency digital ultrasound (VHF digital ultrasound), and a Scheimpflug imaging system. Agreement between methods was analyzed using mean differences (bias) (OCT - VHF digital ultrasound, OCT - Scheimpflug, VHF digital ultrasound - Scheimpflug) and Bland-Altman analysis with 95% limits of agreement (LoA). Virgin cornea mean central corneal thickness was 508.3 ± 33.2 µm (range: 434 to 588 µm) for OCT, 512.7 ± 32.2 µm (range: 440 to 587 µm) for VHF digital ultrasound, and 530.2 ± 32.6 µm (range: 463 to 612 µm) for Scheimpflug imaging. OCT and VHF digital ultrasound showed the closest agreement with a bias of -4.37 µm, 95% LoA ±12.6 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -21.9 µm, 95% LoA ±20.7 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -17.5 µm, 95% LoA ±19.0 µm. In post-laser refractive surgery corneas, mean central corneal thickness was 417.9 ± 47.1 µm (range: 342 to 557 µm) for OCT, 426.3 ± 47.1 µm (range: 363 to 563 µm) for VHF digital ultrasound, and 437.0 ± 48.5 µm (range: 359 to 571 µm) for Scheimpflug imaging. Closest agreement was between OCT and VHF digital ultrasound with a bias of -8.45 µm, 95% LoA ±13.2 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -19.2 µm, 95% LoA ±19.2 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -10.7 µm, 95% LoA ±20.0 µm. No relationship was observed between difference in central corneal thickness measurements and mean central corneal thickness. Results were similar for minimum corneal thickness. Central and minimum corneal thickness was measured thinnest by OCT and thickest by Scheimpflug imaging in both groups. A clinically

  17. Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications.

    PubMed

    Bhaskar, Vaishnavi; Chan, Hsun-Liang; MacEachern, Mark; Kripfgans, Oliver D

    2018-05-23

    Ultrasonography has shown promising diagnostic value in dental implant imaging research; however, exactly how ultrasound was used and at what stage of implant therapy it can be applied has not been systematically evaluated. Therefore, the aim of this review is to investigate potential indications of ultrasound use in the three implant treatment phases, namely planning, intraoperative and postoperative phase. Eligible manuscripts were searched in major databases with a combination of key words related to the use of ultrasound imaging in implant therapy. An initial search yielded 414 articles, after further review, 28 articles were finally included for this systematic review. Ultrasound was found valuable, though at various development stages, for evaluating (1) soft tissues, (2) hard tissues (3) vital structures and (4) implant stability. B-mode, the main function to image anatomical structures of interest, has been evaluated in pre-clinical and clinical studies. Quantitative ultrasound parameters, e.g. sound speed and amplitude, are being developed to evaluate implant-bone stability, mainly in simulation and pre-clinical studies. Ultrasound could be potentially useful in all 3 treatment phases. In the planning phase, ultrasound could evaluate vital structures, tissue biotype, ridge width/density, and cortical bone thickness. During surgery, it can provide feedback by identifying vital structures and bone boundary. At follow-up visits, it could evaluate marginal bone level and implant stability. Understanding the current status of ultrasound imaging research for implant therapy would be extremely beneficial for accelerating translational research and its use in dental clinics.

  18. Ultrasound phonophoresis of panax notoginseng improves the strength of repairing ligament: a rat model.

    PubMed

    Ng, Gabriel Y F; Wong, Richard Y F

    2008-12-01

    This study examined the phonophoretic effect of a therapeutic ultrasound coupled with a Panax notoginseng (PN) gel and compared it with a therapeutic ultrasound alone for medial collateral ligament repair in rats. Twenty mature male Sprague-Dawley rats receiving surgical transection to the left medial collateral ligament (MCL) were divided randomly into three groups: ultrasound (US, n = 7), ultrasound with PN coupling gel (PNUS, n = 7) and control (n = 6). The treatments started on day 3 after surgery for six days per week over a two-week period. The US group received 4 min of pulsed ultrasound (1 MHz) at the intensity of 0.5W/cm(2) with a normal ultrasonic coupling gel. The PNUS group received the same ultrasound treatment, but with a coupling gel that contained PN extract. The control group received a placebo ultrasound treatment similar to the other two groups. On day 17, the ligaments were mechanically tested for load-relaxation, stiffness and ultimate tensile strength (UTS). Values of the left side were normalized against that of the right side of each animal for analysis. Results revealed significantly higher normalized stiffness (p = 0.009) and UTS (p = 0.022) in the PNUS group than the other two groups, but insignificant difference in load-relaxation among all groups. This study reveals a positive ultrasonic phonophoretic effect of Panax notoginseng extract for improving the strength of ligament repair than ultrasound therapy alone.

  19. Assessing the effect of different operation techniques on postoperative duplex ultrasound quality after carotid endarterectomy.

    PubMed

    Grambow, E; Heller, T; Wieneke, P; Weiß, C; Klar, E; Weinrich, M

    2018-01-01

    Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound.

  20. Therapeutic Ultrasound Bypasses Canonical Syndecan-4 Signaling to Activate Rac1*S⃞

    PubMed Central

    Mahoney, Claire M.; Morgan, Mark R.; Harrison, Andrew; Humphries, Martin J.; Bass, Mark D.

    2009-01-01

    The application of pulsed, low intensity ultrasound is emerging as a potent therapy for the treatment of complex bone fractures and tissue damage. Ultrasonic stimuli accelerate fracture healing by up to 40% and enhance tendon and ligament healing by promoting cell proliferation, migration, and matrix synthesis through an unresolved mechanism. Ultrasound treatment also induces closure of nonunion fractures, at a success rate (85% of cases) similar to that of surgical intervention (68-96%) while avoiding the complications associated with surgery. The regulation of cell adhesion necessary for wound healing depends on cooperative engagement of the extracellular matrix receptors, integrin and syndecan, as exemplified by the wound healing defects observed in syndecan- and integrin-knock-out mice. This report distinguishes the influence of ultrasound on signals downstream of the prototypic fibronectin receptors, α5β1 integrin and syndecan-4, which cooperate to regulate Rac1 and RhoA. Ultrasonic stimulation fails to activate integrins or induce cell spreading on poor, electrostatic ligands. By contrast, ultrasound treatment overcomes the necessity of engagement or expression of syndecan-4 during the process of focal adhesion formation, which normally requires simultaneous engagement of both receptors. Ultrasound exerts an influence downstream of syndecan-4 and PKCα to specifically activate Rac1, itself a critical regulator of tissue repair, and to a lesser extent RhoA. The ability of ultrasound to bypass syndecan-4 signaling, which is known to facilitate efficient tissue repair, explains the reduction in healing times observed in ultrasound-treated patients. By substituting for one of the key axes of adhesion-dependent signaling, ultrasound therapy has considerable potential as a clinical technique. PMID:19147498

  1. Microfocused ultrasound for skin tightening.

    PubMed

    MacGregor, Jennifer L; Tanzi, Elizabeth L

    2013-03-01

    The demand for noninvasive skin tightening procedures is increasing as patients seek safe and effective alternatives to aesthetic surgical procedures of the face, neck, and body. Over the past decade, radiofrequency and infrared laser devices have been popularized owing to their ability to deliver controlled heat to the dermis, stimulate neocollagenesis, and effect modest tissue tightening with minimal recovery. However, these less invasive approaches are historically associated with inferior efficacy so that surgery still remains the treatment of choice to address moderate to severe tissue laxity. Microfocused ultrasound was recently introduced as a novel energy modality for transcutaneous heat delivery that reaches the deeper subdermal connective tissue in tightly focused zones at consistent programmed depths. The goal is to produce a deeper wound healing response at multiple levels with robust collagen remodeling and a more durable clinical response. The Ulthera device (Ulthera, Inc, Meza, AZ), with refined microfocused ultrasound technology, has been adapted specifically for skin tightening and lifting with little recovery or risk of complications since its introduction in 2009. As clinical parameters are studied and optimized, enhanced efficacy and consistency of clinical improvement is expected.

  2. Breast ultrasound in the management of gynecomastia in Peutz-Jeghers syndrome in monozygotic twins: two case reports.

    PubMed

    Di Grezia, Graziella; Romano, Tiziana; De Francesco, Francesco; Somma, Francesco; Rea, Gaetano; Grassi, Roberto; Gatta, Gianluca

    2014-12-18

    Peutz-Jeghers syndrome is an autosomal dominant disease with incomplete penetrance and variable expression caused by germline mutation of serine threonine kinase 11/liver kinase B1; it is characterized by hamartomatous polyps in the gastrointestinal tract, mucocutaneous melanin pigmentation, and increased predisposition to neoplasms. In Peutz-Jeghers syndrome, bilateral Sertoli cell testicular tumors cause endocrine manifestations including gynecomastia and feminization. This study aimed to assess the role of breast ultrasound in the evaluation of the effectiveness of an innovative surgical approach. This report presents a pair of European 9-year-old identical male twins with Peutz-Jeghers syndrome, bilateral prepubertal gynecomastia, and testicular multifocal calcifications. Both twins were treated with anastrozole for 2 years. After finishing treatment, both underwent subcutaneous mastectomy performed by the "modified" Webster technique. Breast examination and ultrasound were performed before and after the pharmacological and surgical treatment. A breast ultrasound scan before surgery showed bilateral gynecomastia in both patients. No solid nodular or cystic formations were present on either side. After pharmacological therapy and surgical glandular removal, a breast examination showed a significant reduction in breast volume; 1 year after surgery, a breast ultrasound scan of both patients showed a total absence of glandular parenchyma, with muscle planes well represented. Breast examination and ultrasound have proved to be a valid approach in the assessment of the treatment of prepubertal gynecomastia because they allow the efficacy of the pharmacological and surgical treatment to be evaluated in a multidisciplinary approach to one of the most frequent endocrine manifestations of Peutz-Jeghers syndrome.

  3. [Ultrasound examination for lower extremity deep vein thrombosis].

    PubMed

    Toyota, Kosaku

    2014-09-01

    Surgery is known to be a major risk factor of vein thrombosis. Progression from lower extremity deep vein thrombosis (DVT) to pulmonary embolism can lead to catastrophic outcome, although the incidence ratio is low. The ability to rule in or rule out DVT is becoming essential for anesthesiologists. Non-invasive technique of ultrasonography is a sensitive and specific tool for the assessment of lower extremity DVT. This article introduces the basics and practical methods of ultrasound examination for lower extremity DVT.

  4. Efficacy of Ultrasound-Guided Serratus Plane Block on Postoperative Quality of Recovery and Analgesia After Video-Assisted Thoracic Surgery: A Randomized, Triple-Blind, Placebo-Controlled Study.

    PubMed

    Kim, Do-Hyeong; Oh, Young Jun; Lee, Jin Gu; Ha, Donghun; Chang, Young Jin; Kwak, Hyun Jeong

    2018-04-01

    The optimal regional technique for analgesia and improved quality of recovery after video-assisted thoracic surgery (a procedure associated with considerable postoperative pain) has not been established. The main objective in this study was to compare quality of recovery in patients undergoing serratus plane block (SPB) with either ropivacaine or normal saline on the first postoperative day. Secondary outcomes were analgesic outcomes, including postoperative pain intensity and opioid consumption. Ninety patients undergoing video-assisted thoracic surgery were randomized to receive ultrasound-guided SPB with 0.4 mL/kg of either 0.375% ropivacaine (SPB group) or normal saline (control group) after anesthetic induction. The primary outcome was the 40-item Quality of Recovery (QoR-40) score at 24 hours after surgery. The QoR-40 questionnaire was completed by patients the day before surgery and on postoperative days 1 and 2. Pain scores, opioid consumption, and adverse events were assessed for 2 days postoperatively. Eighty-five patients completed the study: 42 in the SPB group and 43 in the control group. The global QoR-40 scores on both postoperative days 1 and 2 were significantly higher in the SPB group than in the control group (estimated mean difference 8.5, 97.5% confidence interval [CI], 2.1-15.0, and P = .003; 8.5, 97.5% CI, 2.0-15.1, and P = .004, respectively). The overall mean difference between the SPB and control groups was 8.5 (95% CI, 3.3-13.8; P = .002). Pain scores at rest and opioid consumption were significantly lower up to 6 hours after surgery in the SPB group than in the control group. Cumulative opioid consumption was significantly lower up to 24 hours postoperatively in the SPB group. Single-injection SPB with ropivacaine enhanced the quality of recovery for 2 days postoperatively and improved postoperative analgesia during the early postoperative period in patients undergoing video-assisted thoracic surgery.

  5. Safety and efficiency of ultrasound-guided intermediate cervical plexus block for carotid surgery.

    PubMed

    Leblanc, Isabelle; Chterev, Vladimir; Rekik, Mohamed; Boura, Benoit; Costanzo, Alessandro; Bourel, Patrick; Combes, Myriam; Philip, Ivan

    2016-04-01

    Since stroke and myocardial ischaemia are major causes of perioperative morbidity and mortality associated with carotid endarterectomy, monitoring the brain and ensuring the best haemodynamic stability are important goals of the management. As regional anaesthesia was reported to improve haemodynamic stability during carotid endarterectomy (CEA), we conducted a prospective observational study on the efficacy and safety of ultrasound-guided intermediate cervical plexus blocks (CPB), with early (immediate postoperative) and mid-term (day 30) outcomes in awake patients undergoing CEA. After the ethics committee approval, 50 patients undergoing a carotid endarterectomy with CPB from April 2011 to May 2013 were included. Anaesthesia and surgical dissection parameters, early complications and haemodynamic stability were recorded, as well as neurologic and cardiac outcomes initially and one month later. Cervical space was easy to locate by ultrasound in 90% of the patients. The quality of anaesthesia and surgical dissection was good in 86 and 88% of patients, respectively. No conversion to GA was required, secondary to a lack of analgesia. Two patients (4%) had severe hypotension (<100mmHg). Three patients required a shunt after carotid clamping for loss of consciousness with a favourable neurological outcome. We observed one elevation of cTnI (0.95ng·ml(-1)) without ECG change and 1 death occurred after a postoperative haemorrhagic stroke. The present work reports our first 50 cases of intermediate CPB using ultrasound guidance. The results underline that this technique is easy to perform, safe and reliable, provided good surgical conditions with continuous intraoperative neurologic monitoring and stable haemodynamics are respected. Copyright © 2016. Published by Elsevier Masson SAS.

  6. Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.

    PubMed

    Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman

    2013-10-01

    Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.

  7. Risk of deep venous thrombosis in elective neurosurgical procedures: a prospective, Doppler ultrasound-based study in children 12 years of age or younger.

    PubMed

    Scherer, Andrea G; White, Ian K; Shaikh, Kashif A; Smith, Jodi L; Ackerman, Laurie L; Fulkerson, Daniel H

    2017-07-01

    OBJECTIVE The risk of venous thromboembolism (VTE) from deep venous thrombosis (DVT) is significant in neurosurgical patients. VTE is considered a leading cause of preventable hospital deaths and preventing DVT is a closely monitored quality metric, often tied to accreditation, hospital ratings, and reimbursement. Adult protocols include prophylaxis with anticoagulant medications. Children's hospitals may adopt adult protocols, although the incidence of DVT and the risk or efficacy of treatment is not well defined. The incidence of DVT in children is likely less than in adults, although there is very little prospectively collected information. Most consider the risk of DVT to be extremely low in children 12 years of age or younger. However, this consideration is based on tradition and retrospective reviews of trauma databases. In this study, the authors prospectively evaluated pediatric patients undergoing a variety of elective neurosurgical procedures and performed Doppler ultrasound studies before and after surgery. METHODS A total of 100 patients were prospectively enrolled in this study. All of the patients were between the ages of 1 month and 12 years and were undergoing elective neurosurgical procedures. The 91 patients who completed the protocol received a bilateral lower-extremity Doppler ultrasound examination within 48 hours prior to surgery. Patients did not receive either medical or mechanical DVT prophylaxis during or after surgery. The ultrasound examination was repeated within 72 hours after surgery. An independent, board-certified radiologist evaluated all sonograms. We prospectively collected data, including potential risk factors, details of surgery, and details of the clinical course. All patients were followed clinically for at least 1 year. RESULTS There was no clinical or ultrasound evidence of DVT or VTE in any of the 91 patients. There was no clinical evidence of VTE in the 9 patients who did not complete the protocol. CONCLUSIONS In this

  8. Real-Time Ultrasound-Guided Spinal Anaesthesia: A Prospective Observational Study of a New Approach

    PubMed Central

    Conroy, P. H.; Luyet, C.; McCartney, C. J.; McHardy, P. G.

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1–6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83–4.1) demonstrating the feasibility of this technique in routine clinical practice. PMID:23365568

  9. Piezoelectric osteotomy in hand surgery: first experiences with a new technique

    PubMed Central

    Hoigne, Dominik J; Stübinger, Stefan; Kaenel, Oliver Von; Shamdasani, Sonia; Hasenboehler, Paula

    2006-01-01

    Background In hand and spinal surgery nerve lesions are feared complications with the use of standard oscillating saws. Oral surgeons have started using a newly developed ultrasound bone scalpel when performing precise osteotomies. By using a frequency of 25–29 kHz only mineralized tissue is cut, sparing the soft tissue. This reduces the risk of nerve lesions. As there is a lack of experience with this technique in the field of orthopaedic bone surgery, we performed the first ultrasound osteotomy in hand surgery. Method While performing a correctional osteotomy of the 5th metacarpal bone we used the Piezosurgery® Device from Mectron [Italy] instead of the usual oscillating saw. We will report on our experience with one case, with a follow up time of one year. Results The cut was highly precise and there were no vibrations of the bone. The time needed for the operation was slightly longer than the time needed while using the usual saw. Bone healing was good and at no point were there any neurovascular disturbances. Conclusion The Piezosurgery® Device is useful for small long bone osteotomies. Using the fine tip enables curved cutting and provides an opportunity for new osteotomy techniques. As the device selectively cuts bone we feel that this device has great potential in the field of hand- and spinal surgery. PMID:16611362

  10. Prevalence of incidental pancreatic cyst on upper endoscopic ultrasound

    PubMed Central

    Martínez, Belén; Martínez, Juan F.; Aparicio, José R.

    2018-01-01

    Background: This study aimed to determine the prevalence of incidental pancreatic cysts in patients undergoing upper endoscopic ultrasound without a known pancreatic abnormality. Methods: This prospective study was conducted in two hospitals in Spain and enrolled consecutive patients referred for upper endoscopic ultrasound for a condition unrelated to the pancreas. Patients with a previous pancreatic anomaly, history of acute or chronic pancreatitis, evidence of acute pancreatitis, previous upper gastrointestinal surgery, or chronic abdominal pain suggestive of pancreatic origin were excluded. Univariate logistic regression was performed to evaluate individual covariates and the incidental pancreatic cyst risk. Results: A total of 298 patients were included, of whom 64 had pancreatic cysts (21.5%; 16.9-26.6%). The mean size of the cysts was 6.3±3.7 (range 3-25) mm. Six cysts (2%) were >10 mm and 16 (5.4%) were compatible with branch duct intraductal papillary mucinous neoplasm. The pancreatic cyst prevalence was similar in the two hospitals and increased significantly with age. Conclusion: The prevalence of incidental pancreatic cysts during endoscopic ultrasound was very high in our study population. PMID:29333072

  11. The characteristic ultrasound features of specific types of ovarian pathology (Review)

    PubMed Central

    SAYASNEH, AHMAD; EKECHI, CHRISTINE; FERRARA, LAURA; KAIJSER, JEROEN; STALDER, CATRIONA; SUR, SHYAMALY; TIMMERMAN, DIRK; BOURNE, TOM

    2015-01-01

    Characterizing ovarian masses enables patients with malignancy to be appropriately triaged for treatment by subspecialist gynecological oncologists, which has been shown to optimize care and improve survival. Furthermore, correctly classifying benign masses facilitates the selection of patients with ovarian pathology that may either not require intervention, or be suitable for minimal access surgery if intervention is required. However, predicting whether a mass is benign or malignant is not the only clinically relevant information that we need to know before deciding on appropriate treatment. Knowing the specific histology of a mass is becoming of increasing importance as management options become more tailored to the individual patient. For example predicting a mucinous borderline tumor gives the opportunity for fertility sparing surgery, and will highlight the need for further gastrointestinal assessment. For benign disease, predicting the presence of an endometrioma and possible deeply infiltrating endometriosis is important when considering both who should perform and the extent of surgery. An examiner’s subjective assessment of the morphological and vascular features of a mass using ultrasonography has been shown to be highly effective for predicting whether a mass is benign or malignant. Many masses also have features that enable a reliable diagnosis of the specific pathology of a particular mass to be made. In this narrative review we aim to describe the typical morphological features seen on ultrasound of different adnexal masses and illustrate these by showing representative ultrasound images. PMID:25406094

  12. Ultrasound - Breast

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...

  13. Obstetric Ultrasound

    PubMed Central

    Nicholson, Stuart F.; Nimrod, Carl A.

    1988-01-01

    This article addresses the current indications for an obstetric ultrasound and describes the findings that it is reasonable to expect when reading an ultrasound report. The authors discuss several common obstetrical problems focussing the attention on the usefulness of the imaging information. Finally, they provide a glimpse into the future direction of obstetric ultrasound by discussing vaginal scanning, Doppler assessment of fetal blood flow, and routine ultrasound in pregnancy. PMID:21253229

  14. Subjective ultrasound assessment, the ADNEX model and ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer.

    PubMed

    Epstein, E; Van Calster, B; Timmerman, D; Nikman, S

    2016-01-01

    To compare subjective ultrasound assessment and the ADNEX model with ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer. This was a prospective study including 143 consecutive women with disseminated malignancy of unknown primary origin, with a pelvic tumor/carcinosis. Women underwent either transvaginal or transrectal ultrasound as well as transabdominal ultrasound examination followed by tru-cut biopsy. The ultrasound examiner assessed tumor morphology, spread in the pelvis and abdomen, and predicted tumor origin as primary ovarian or metastatic using both subjective assessment and the ADNEX model. Histology from tru-cut biopsy served as the gold standard for assessment of diagnostic accuracy. Biopsy adequacy and the complication rate were assessed. Tru-cut biopsy was performed transvaginally in 131/143 (92%) women. Two women needed inpatient care (one had abdominal wall hematoma, and one infection). Biopsy resulted in a conclusive diagnosis in 126/143 (88%) women, amongst whom cytoreductive surgery was performed in 30/126 confirming the diagnosis in all cases. Non-ovarian metastatic cancer was found in 37/126 (29%) women and primary ovarian cancer in 89/126 (71%) women. Subjective ultrasound evaluation had a sensitivity of 82% (73/89) and a specificity of 70% (26/37) in predicting primary ovarian cancer. The ADNEX model had an area under the receiver-operating characteristics curve of 0.891 (95% CI, 0.794-0.946) (in women with an ovarian lesion, n = 104). Tumor origin was associated with age, CA 125, previous neoplasia, presence of omental cake and tumor mobility. Subjective ultrasound assessment and the ADNEX model can both be used to predict whether a pelvic tumor is metastatic and of non-ovarian origin, indicating the need for tru-cut biopsy, which is associated with very few complications and will provide a conclusive diagnosis in nine out of 10 women. Copyright © 2015 ISUOG

  15. Accuracy of ultrasound in prediction of rectosigmoid infiltration in epithelial ovarian cancer.

    PubMed

    Zikan, M; Fischerova, D; Semeradova, I; Slama, J; Dundr, P; Weinberger, V; Dusek, L; Cibula, D

    2017-10-01

    To examine prospectively the accuracy of ultrasound in predicting rectosigmoid tumor infiltration in patients with epithelial ovarian cancer. Patients referred for a suspicious pelvic mass between 2012 and 2014 were examined by ultrasound following the standard protocol for assessment of tumor infiltration. Of the 245 patients examined, 191 had proven ovarian cancer and underwent primary surgery and were included in the analysis. Patients with apparently benign or inoperable disease were excluded. Rectosigmoid infiltration was evaluated by histopathology or according to perioperative findings. Clinical, pathological and laboratory parameters were analyzed as factors potentially affecting the sensitivity and specificity of sonography. The sensitivity of ultrasound in detecting rectosigmoid infiltration in patients with ovarian cancer was 86.3%, with specificity of 95.8%, positive predictive value of 92.6%, negative predictive value of 91.9% and overall accuracy of 92.1%. Ultrasound is a highly accurate method for detecting rectosigmoid tumor infiltration in ovarian cancer patients, and thus, can be used for planning adequate management, including patient consultation, surgical team planning, suitable operating time and postoperative care. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  16. Enhanced Delivery of Gold Nanoparticles with Therapeutic Potential for Targeting Human Brain Tumors

    NASA Astrophysics Data System (ADS)

    Etame, Arnold B.

    -transport permissive and intact BBB, we also assessed the role of magnetic resonance imaging (MRI) guided focused ultrasound (MRgFUS) disruption of the BBB in enhancing permeation of AuNPs across the intact BBB and tumor BBB in vivo. MRgFUS is a novel technique that can transiently increase BBB permeability thereby allowing delivery of therapeutics into the CNS. We demonstrated enhanced delivery of AuNPs with therapeutic potential into the CNS via MRgFUS. Our study was the first to establish a definitive role for MRgFUS in delivering AuNPs into the CNS. In summary, this thesis describes results from a series of research projects that have contributed to our understanding of the influence of design features on AuNP permeation through the BBB and also the potential role of MRgFUS in AuNP permeation across the BBB.

  17. Resolution of carotid stenosis pre-carotid intervention: A case for selective preoperative duplex ultrasound.

    PubMed

    Ali, Abid; Ashrafi, Mohammed; Zeynali, Iraj

    2015-01-01

    Spontaneous resolution of carotid stenosis is a phenomenon that has been described in literature in the past. At present it is not routine practise to scan patients prior to carotid endarterectomy surgery within the UK. A 58 year old female presented to hospital with a history of sudden onset headache and left sided weakness. CT head showed findings in keeping with an acute right MCA territory infarct. A duplex ultrasound scan showed echolucent material in the right internal carotid artery forming a greater than 95% stenosis. The scan was unable to visualise the patency of the vessel distally due to the position of the mandible. The patient was provisionally listed for carotid endarterectomy. An MRA was requested prior to surgery to assess the patency of the distal internal carotid artery. The MRA of the carotids showed normal appearance of the common carotid, internal and vertebral arteries with no definite stenosis. A repeat duplex ultrasound confirmed there was no significant stenosis. The finding of complete resolution of stenosis on MRA was an unexpected event. Had the initial duplex imaging allowed visualisation of the distal vessel patency, our patient would have undergone unnecessary carotid surgery with the associated morbidity and mortality. This case report draws attention to the benefits of selective preoperative scanning, in sparing patients from unnecessary surgery as a result of finding occlusion or resolution of a previously diagnosed carotid stenosis. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. An effective non-rigid registration approach for ultrasound image based on "demons" algorithm.

    PubMed

    Liu, Yan; Cheng, H D; Huang, Jianhua; Zhang, Yingtao; Tang, Xianglong; Tian, Jiawei

    2013-06-01

    Medical image registration is an important component of computer-aided diagnosis system in diagnostics, therapy planning, and guidance of surgery. Because of its low signal/noise ratio (SNR), ultrasound (US) image registration is a difficult task. In this paper, a fully automatic non-rigid image registration algorithm based on demons algorithm is proposed for registration of ultrasound images. In the proposed method, an "inertia force" derived from the local motion trend of pixels in a Moore neighborhood system is produced and integrated into optical flow equation to estimate the demons force, which is helpful to handle the speckle noise and preserve the geometric continuity of US images. In the experiment, a series of US images and several similarity measure metrics are utilized for evaluating the performance. The experimental results demonstrate that the proposed method can register ultrasound images efficiently, robust to noise, quickly and automatically.

  19. Is routine ultrasound guidance for central line placement beneficial? A prospective analysis.

    PubMed

    Martin, Matthew J; Husain, Farah A; Piesman, Michael; Mullenix, Philip S; Steele, Scott R; Andersen, Charles A; Giacoppe, George N

    2004-01-01

    Portable ultrasound devices have become more readily available in the intensive care unit setting, but their utility outside of controlled trials remains unproven. We sought to determine how the availability of ultrasound guidance affected the types and number of complications during central line placement. Review of a prospectively maintained database in a 20-bed combined intensive care unit. Procedure notes from all attempts at internal jugular vein access from 1996 to 2001 were recorded, and selected patient records were reviewed. Ultrasound guidance was available beginning in March 1998. From 1996 to 2001, there were 484 documented attempts at internal jugular central line placement. Most procedures (83%) were performed by first- or second-year residents. During this period, there were 47 complications for an overall complication rate of 10%. These included 1 pneumothorax (2%), 6 carotid punctures (13%), 2 hematomas (4%), and 34 unsuccessful attempts (72%). There was no significant difference in age, sex, body-mass index, or intubation status between those with and without complications or between the ultrasound and anatomic landmark groups. Ultrasound was used in 179 (37%) attempts. The overall complication rate with ultrasound was 11% versus 9% using anatomic landmarks (p = NS). The complication rate prior to the availability of ultrasound was 15 of 114 attempts (13%) versus 32 of 370 attempts (9%) after the introduction of ultrasound in our intensive care unit (p = NS). Analysis of the 370 procedures performed since ultrasound became available demonstrated a complication rate of 11% with ultrasound guidance versus 6% without (p = 0.09). There was no significant difference in complication rates by resident year group or department (surgery vs. other). However, procedures performed after-hours (1800 to 0800) were associated with a 15% complication rate versus 6% for procedures performed during the workday (p < 0.05). The availability and use of ultrasound

  20. Musculoskeletal ultrasound in rheumatology in Korea: targeted ultrasound initiative survey.

    PubMed

    Kang, Taeyoung; Wakefield, Richard J; Emery, Paul

    2016-04-01

    In collaboration with the Targeted Ultrasound Initiative (TUI), to conduct the first study in Korea to investigate current practices in ultrasound use among Korean rheumatologists. We translated the TUI Global Survey into Korean and added questions to better understand the specific challenges facing rheumatologists in Korea. To target as many rheumatologists in Korea as possible, we created an on-line version of this survey, which was conducted from March to April 2013. Rheumatologists are in charge of ultrasound in many Korean hospitals. Rheumatologists in hospitals and private clinics use ultrasound to examine between one and five patients daily; they use ultrasound for diagnosis more than monitoring and receive compensation of about US$30-50 per patient. There are marked differences in the rates of ultrasound usage between rheumatologists who work in private practice compared with tertiary hospitals. Korean rheumatologists not currently using ultrasound in their practice appear eager to do so. This survey provides important insights into the current status of ultrasound in rheumatology in Korea and highlights several priorities; specifically, greater provision of formal training, standardization of reporting and accrual of greater experience among ultrasound users. If these needs are addressed, all rheumatology departments in Korea are likely to use ultrasound or have access to it in the future. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  1. Benefit of 18F-fluorocholine PET imaging in parathyroid surgery.

    PubMed

    Huber, G F; Hüllner, M; Schmid, C; Brunner, A; Sah, B; Vetter, D; Kaufmann, P A; von Schulthess, G K

    2018-06-01

    To assess the additional diagnostic value of 18 F-fluorocholine PET imaging in preoperative localization of pathologic parathyroid glands in clinically manifest hyperparathyroidism in case of negative or conflicting ultrasound and scintigraphy results. A retrospective, single-institution study of 26 patients diagnosed with hyperparathyroidism. In cases where ultrasound and scintigraphy failed to detect the location of an adenoma in order to allow a focused surgical approach, an additional 18 F-fluorocholine PET scan was performed and its results were compared with the intraoperative findings. A total of 26 patients underwent 18 F-fluorocholine PET/CT (n = 11) or PET/MRI (n = 15). Adenomas were detected in 25 patients (96.2%). All patients underwent surgery, and the location predicted by PET hybrid imaging was confirmed intraoperatively by frozen section and adequate parathyroid hormone drop after removal. None of the patients needed revision surgery during follow-up. These results demonstrate that 18 F-fluorocholine PET imaging is a highly accurate method to detect parathyroid adenomas even in case of previous localization failure by other imaging examinations. • With 18 F-fluorocholine PET imaging, parathyroid adenomas could be detected in 96.2%. • 18 F-fluorocholine imaging is a highly accurate method to detect parathyroid adenomas. • We encourage its use, where ultrasound fails to detect an adenoma.

  2. Anaesthetic considerations for pectus repair surgery

    PubMed Central

    Patvardhan, Chinmay

    2016-01-01

    Repair of pectus is one of the most common congenital abnormality for which patient presents for thoracic surgery. In recent years, innovative minimally invasive techniques involving video assisted thoracoscopy for pectus repair have become the norm. Similarly, anaesthetic techniques have evolved to include principles of enhanced recovery, multimodal analgesia and innovative ultrasound guided neuraxial and nerve blocks. Adequate anaesthetic set up and monitoring including the use of real time intraoperative monitoring with transesophageal echocardiography (TOE) has enabled the anaesthetist to enhance patient safety by providing instantaneous imaging of cardiac compression and complications during surgery. In this review article we aim to provide non-systematic review and institutional experience of our anaesthetic strategy to provide effective peri-operative care in this patient group. PMID:29078504

  3. Cavitation and contrast: the use of bubbles in ultrasound imaging and therapy.

    PubMed

    Stride, E P; Coussios, C C

    2010-01-01

    Microbubbles and cavitation are playing an increasingly significant role in both diagnostic and therapeutic applications of ultrasound. Microbubble ultrasound contrast agents have been in clinical use now for more than two decades, stimulating the development of a range of new contrast-specific imaging techniques which offer substantial benefits in echocardiography, microcirculatory imaging, and more recently, quantitative and molecular imaging. In drug delivery and gene therapy, microbubbles are being investigated/developed as vehicles which can be loaded with the required therapeutic agent, traced to the target site using diagnostic ultrasound, and then destroyed with ultrasound of higher intensity energy burst to release the material locally, thus avoiding side effects associated with systemic administration, e.g. of toxic chemotherapy. It has moreover been shown that the motion of the microbubbles increases the permeability of both individual cell membranes and the endothelium, thus enhancing therapeutic uptake, and can locally increase the activity of drugs by enhancing their transport across biologically inaccessible interfaces such as blood clots or solid tumours. In high-intensity focused ultrasound (HIFU) surgery and lithotripsy, controlled cavitation is being investigated as a means of increasing the speed and efficacy of the treatment. The aim of this paper is both to describe the key features of the physical behaviour of acoustically driven bubbles which underlie their effectiveness in biomedical applications and to review the current state of the art.

  4. Ultrasound Elasticity Imaging Predicts Therapeutic Outcomes of Patients With Crohn's Disease Treated With Anti-Tumour Necrosis Factor Antibodies.

    PubMed

    Orlando, Stefania; Fraquelli, Mirella; Coletta, Marina; Branchi, Federica; Magarotto, Andrea; Conti, Clara Benedetta; Mazza, Stefano; Conte, Dario; Basilisco, Guido; Caprioli, Flavio

    2018-01-05

    Ultrasound elasticity imaging is a non-invasive technique developed to evaluate fibrosis. Measuring tissue strain by ultrasound elasticity imaging can reliably detect severe ileal fibrosis in patients with Crohn's disease [CD]. We have hypothesised that a more severe range of fibrosis might influence the therapeutic response to anti-tumour necrosis factor [TNF] treatment. The aim of this study was to assess the ability of ultrasound elasticity imaging to predict the therapeutic outcome for CD patients. Consecutive patients with ileal/ileocolonic CD, starting anti-TNF treatment, were enrolled for the study. These patients underwent bowel ultrasound and ultrasound elasticity imaging at baseline and at 14 and 52 weeks after anti-TNF treatment. Bowel wall stiffness was quantified by calculating the strain ratio between the mesenteric tissue and the bowel wall. Strain ratio ≥ 2 was used to identify severe ileal fibrosis. Transmural healing at 14 and 52 weeks was defined as bowel wall thickness ≤ 3 mm. Thirty patients with CD were enrolled. Five patients underwent surgery for bowel obstruction. The frequency of surgeries was significantly greater in patients with a strain ratio ≥ 2 at baseline [p = 0.003]. A significant reduction of the bowel thickness was observed after 14 and 52 weeks of anti-TNF treatment [p < 0.005]. A significant inverse correlation was observed between the strain ratio values at baseline and the thickness variations following anti-TNF therapy [p = 0.007]; 27% of patients achieved transmural healing at 14 weeks. The baseline strain ratio was significantly lower in patients with transmural healing [p < 0.05]. This study shows that ultrasound elasticity imaging predicts therapeutic outcomes for CD patients treated with anti-TNF. Copyright © 2017 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com

  5. Integrated medical school ultrasound: development of an ultrasound vertical curriculum.

    PubMed

    Bahner, David P; Adkins, Eric J; Hughes, Daralee; Barrie, Michael; Boulger, Creagh T; Royall, Nelson A

    2013-07-02

    Physician-performed focused ultrasonography is a rapidly growing field with numerous clinical applications. Focused ultrasound is a clinically useful tool with relevant applications across most specialties. Ultrasound technology has outpaced the education, necessitating an early introduction to the technology within the medical education system. There are many challenges to integrating ultrasound into medical education including identifying appropriately trained faculty, access to adequate resources, and appropriate integration into existing medical education curricula. As focused ultrasonography increasingly penetrates academic and community practices, access to ultrasound equipment and trained faculty is improving. However, there has remained the major challenge of determining at which level is integrating ultrasound training within the medical training paradigm most appropriate. The Ohio State University College of Medicine has developed a novel vertical curriculum for focused ultrasonography which is concordant with the 4-year medical school curriculum. Given current evidenced-based practices, a curriculum was developed which provides medical students an exposure in focused ultrasonography. The curriculum utilizes focused ultrasonography as a teaching aid for students to gain a more thorough understanding of basic and clinical science within the medical school curriculum. The objectives of the course are to develop student understanding in indications for use, acquisition of images, interpretation of an ultrasound examination, and appropriate decision-making of ultrasound findings. Preliminary data indicate that a vertical ultrasound curriculum is a feasible and effective means of teaching focused ultrasonography. The foreseeable limitations include faculty skill level and training, initial cost of equipment, and incorporating additional information into an already saturated medical school curriculum. Focused ultrasonography is an evolving concept in medicine

  6. Port-Site Metastases and Chimney Effect of B-Ultrasound-Guided and Laparoscopically-Assisted Hyperthermic Intraperitoneal Perfusion Chemotherapy

    PubMed Central

    Zhang, Xiang-Liang; Gong, Yuan-Feng; Yan, Zhao-Fei; Wang, Shuai; Tang, Yun-Qiang; Cui, Shu-Zhong

    2017-01-01

    Purpose CO2 leakage along the trocar (chimney effect) has been proposed to be an important factor underlying port-site metastasis after laparoscopic surgery. This study aimed to test this hypothesis by comparing the incidence of port-site metastasis between B-ultrasound-guided and laparoscopically-assisted hyperthermic intraperitoneal perfusion chemotherapy (HIPPC). Materials and Methods Sixty-two patients with malignant ascites induced by gastrointestinal or ovarian cancer were divided into two groups to receive either B-ultrasound-guided or laparoscopically-assisted HIPPC. Clinical efficacy was assessed from the objective remission rate (ORR), the Karnofsky Performance Status (KPS) score, and overall survival. The incidence of port-site metastasis was compared between the two groups. Results Patients in the B-ultrasound (n=32) and laparoscopy (n=30) groups were comparable in terms of age, sex, primary disease type, volume of ascites, and free cancer cell (FCC)-positive ascites. After HIPPC, there were no significant differences between the B-ultrasound and laparoscopy groups in the KPS score change, ORR, and median survival time. The incidence of port-site metastasis after HIPPC was not significantly different between the B-ultrasound (3 of 32, 9.36%) and laparoscopy (3 of 30, 10%) groups, but significantly different among pancreatic, gastric, ovarian, and colorectal cancer (33.33, 15.79, 10.00, and 0.00%, p<0.001). Conclusion The chimney effect may not be the key reason for port-site metastasis after laparoscopy. Other factors may play a role, including the local microenvironment at the trocar site and the delivery of viable FCCs (from the tumor or malignant ascites) to the trauma site during laparoscopic surgery. PMID:28332353

  7. Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.

    PubMed

    Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T

    2013-04-01

    Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  8. The use of piezosurgery as an alternative method of minimally invasive surgery in the authors’ experience

    PubMed Central

    Rahnama, Mansur; Czajkowski, Leszek; Grasza, Joanna; Wallner, Jan

    2013-01-01

    Piezosurgery is a relatively new technique of bone surgery that is recently gaining popularity in implantology, periodontics and oral surgery. The piezosurgery device produces specific ultrasound frequency modulation (22 000–35 000 Hz). The unit provides extreme precision and safety as well as micrometric cutting, thus allowing one to selectively section the mineralized bone structures. Moreover, the device causes less bleeding during and after the operation and the healing process is shorter. Due to the aforementioned advantages, an ultrasound device could be utilized in a wide range of surgical procedures, e.g. impacted tooth extraction, elevation of the Schneiderian membrane, bone splitting or expansion of the ridge, preparing bone bed and bone sampling, and corticotomy, not to menton cystectomy. PMID:24501602

  9. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    PubMed

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    . Use of the novel SonixGPS needle-tracking ultrasound system (UltraSonix, Richmond, BC, Canada) was not associated with a higher success rate of vascular puncture compared with the traditional ultrasound-guided technique. Assessment of mental task load significantly favored the use of the ultrasound GPS over the traditional ultrasound technique. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  10. Intraoperative magnetic tracker calibration using a magneto-optic hybrid tracker for 3-D ultrasound-based navigation in laparoscopic surgery.

    PubMed

    Nakamoto, Masahiko; Nakada, Kazuhisa; Sato, Yoshinobu; Konishi, Kozo; Hashizume, Makoto; Tamura, Shinichi

    2008-02-01

    This paper describes a ultrasound (3-D US) system that aims to achieve augmented reality (AR) visualization during laparoscopic surgery, especially for the liver. To acquire 3-D US data of the liver, the tip of a laparoscopic ultrasound probe is tracked inside the abdominal cavity using a magnetic tracker. The accuracy of magnetic trackers, however, is greatly affected by magnetic field distortion that results from the close proximity of metal objects and electronic equipment, which is usually unavoidable in the operating room. In this paper, we describe a calibration method for intraoperative magnetic distortion that can be applied to laparoscopic 3-D US data acquisition; we evaluate the accuracy and feasibility of the method by in vitro and in vivo experiments. Although calibration data can be acquired freehand using a magneto-optic hybrid tracker, there are two problems associated with this method--error caused by the time delay between measurements of the optical and magnetic trackers, and instability of the calibration accuracy that results from the uniformity and density of calibration data. A temporal calibration procedure is developed to estimate the time delay, which is then integrated into the calibration, and a distortion model is formulated by zeroth-degree to fourth-degree polynomial fitting to the calibration data. In the in vivo experiment using a pig, the positional error caused by magnetic distortion was reduced from 44.1 to 2.9 mm. The standard deviation of corrected target positions was less than 1.0 mm. Freehand acquisition of calibration data was performed smoothly using a magneto-optic hybrid sampling tool through a trocar under guidance by realtime 3-D monitoring of the tool trajectory; data acquisition time was less than 2 min. The present study suggests that our proposed method could correct for magnetic field distortion inside the patient's abdomen during a laparoscopic procedure within a clinically permissible period of time, as well as

  11. Consideration of the effects of intense tissue heating on the RF electromagnetic fields during MRI: simulations for MRgFUS in the hip

    NASA Astrophysics Data System (ADS)

    Xuegang Xin, Sherman; Gu, Shiyong; Carluccio, Giuseppe; Collins, Christopher M.

    2015-01-01

    Due to the strong dependence of tissue electrical properties on temperature, it is important to consider the potential effects of intense tissue heating on the RF electromagnetic fields during MRI, as can occur in MR-guided focused ultrasound surgery. In principle, changes of the RF electromagnetic fields could affect both efficacy of RF pulses, and the MRI-induced RF heating (SAR) pattern. In this study, the equilibrium temperature distribution in a whole-body model with 2 mm resolution before and during intense tissue heating up to 60 °C at the target region was calculated. Temperature-dependent electric properties of tissues were assigned to the model to establish a temperature-dependent electromagnetic whole-body model in a 3T MRI system. The results showed maximum changes in conductivity, permittivity, ≤ft|\\mathbf{B}1+\\right|, and SAR of about 25%, 6%, 2%, and 20%, respectively. Though the B1 field and SAR distributions are both temperature-dependent, the potential harm to patients due to higher SARs is expected to be minimal and the effects on the B1 field distribution should have minimal effect on images from basic MRI sequences.

  12. Intensity dependence of focused ultrasound lesion position

    NASA Astrophysics Data System (ADS)

    Meaney, Paul M.; Cahill, Mark D.; ter Haar, Gail R.

    1998-04-01

    Knowledge of the spatial distribution of intensity loss from an ultrasonic beam is critical to predicting lesion formation in focused ultrasound surgery. To date most models have used linear propagation models to predict the intensity profiles needed to compute the temporally varying temperature distributions. These can be used to compute thermal dose contours that can in turn be used to predict the extent of thermal damage. However, these simulations fail to adequately describe the abnormal lesion formation behavior observed for in vitro experiments in cases where the transducer drive levels are varied over a wide range. For these experiments, the extent of thermal damage has been observed to move significantly closer to the transducer with increasing transducer drive levels than would be predicted using linear propagation models. The simulations described herein, utilize the KZK (Khokhlov-Zabolotskaya-Kuznetsov) nonlinear propagation model with the parabolic approximation for highly focused ultrasound waves, to demonstrate that the positions of the peak intensity and the lesion do indeed move closer to the transducer. This illustrates that for accurate modeling of heating during FUS, nonlinear effects must be considered.

  13. Prognostic Value of Ultrasound Grading Systems in Prenatally Diagnosed Unilateral Urinary Tract Dilatation.

    PubMed

    Scalabre, Aurélien; Demède, Delphine; Gaillard, Ségolène; Pracros, Jean-Pierre; Mouriquand, Pierre; Mure, Pierre-Yves

    2017-04-01

    We compared the prognostic value of anteroposterior intrasinus diameter of the renal pelvis, urinary tract dilatation and the Society for Fetal Urology grading system in children with prenatally diagnosed unilateral urinary tract dilatation. All newborns with prenatally diagnosed unilateral urinary tract dilatation, normal bladder and anteroposterior intrasinus diameter 10 mm or greater on the first postnatal ultrasonography were prospectively enrolled from January 2011 to February 2015. Indications for surgery were recurrent febrile urinary tract infections and/or decrease of relative renal function more than 10% on serial isotope studies and/or increasing anteroposterior intrasinus diameter greater than 20% on serial ultrasounds. Sensitivity, specificity and ROC curves were calculated to evaluate the accuracy of anteroposterior intrasinus diameter, urinary tract dilatation and Society for Fetal Urology grading system in determining which children would need surgery within 24 months. A total of 57 males and 13 females were included. Of the patients 33 required surgery at a median age of 5 months (IQR 3.8 to 6.4). Urinary tract dilatation remained stable in 14 cases and decreased in 23 with a median followup of 42 months (IQR 25 to 67). Anteroposterior intrasinus diameter, urinary tract dilatation and Society for Fetal Urology scores were all correlated with the need for surgery. Anteroposterior intrasinus diameter with a threshold of 20 mm had the best prognostic value, with a sensitivity of 81.8% and a specificity of 91.7%. Our study confirms that the prognostic value was comparable between anteroposterior intrasinus diameter of the renal pelvis, urinary tract dilatation and Society for Fetal Urology grading system in newborns with prenatally diagnosed unilateral urinary tract dilatation. Anteroposterior intrasinus diameter and abnormal parenchymal thickness are the most important ultrasound criteria to identify children at risk for requiring surgery

  14. Comparison Between Ultrasound-Guided Supraclavicular and Interscalene Brachial Plexus Blocks in Patients Undergoing Arthroscopic Shoulder Surgery: A Prospective, Randomized, Parallel Study.

    PubMed

    Ryu, Taeha; Kil, Byung Tae; Kim, Jong Hae

    2015-10-01

    Although supraclavicular brachial plexus block (SCBPB) was repopularized by the introduction of ultrasound, its usefulness in shoulder surgery has not been widely reported. The objective of this study was to compare motor and sensory blockades, the incidence of side effects, and intraoperative opioid analgesic requirements between SCBPB and interscalene brachial plexus block (ISBPB) in patients undergoing arthroscopic shoulder surgery. Patients were randomly assigned to 1 of 2 groups (ISBPB group: n = 47; SCBPB group: n = 46). The side effects of the brachial plexus block (Horner's syndrome, hoarseness, and subjective dyspnea), the sensory block score (graded from 0 [no cold sensation] to 100 [intact sensation] using an alcohol swab) for each of the 5 dermatomes (C5-C8 and T1), and the motor block score (graded from 0 [complete paralysis] to 6 [normal muscle force]) for muscle forces corresponding to the radial, ulnar, median, and musculocutaneous nerves were evaluated 20 min after the brachial plexus block. Fentanyl was administered in 50 μg increments when the patients complained of pain that was not relieved by the brachial plexus block. There were no conversions to general anesthesia due to a failed brachial plexus block. The sensory block scores for the C5 to C8 dermatomes were significantly lower in the ISBPB group. However, the percentage of patients who received fentanyl was comparable between the 2 groups (27.7% [ISBPB group] and 30.4% [SCBPB group], P = 0.77). SCBPB produced significantly lower motor block scores for the radial, ulnar, and median nerves than did ISBPB. A significantly higher incidence of Horner's syndrome was observed in the ISBPB group (59.6% [ISBPB group] and 19.6% [SCBPB group], P < 0.001). No patient complained of subjective dyspnea. Despite the weaker degree of sensory blockade provided by SCBPB in comparison to ISBPB, opioid analgesic requirements are similar during arthroscopic shoulder surgery under both brachial plexus blocks

  15. Ultrasound in Arthritis.

    PubMed

    Sudoł-Szopińska, Iwona; Schueller-Weidekamm, Claudia; Plagou, Athena; Teh, James

    2017-09-01

    Ultrasound is currently performed in everyday rheumatologic practice. It is used for early diagnosis, to monitor treatment results, and to diagnose remission. The spectrum of pathologies seen in arthritis with ultrasound includes early inflammatory features and associated complications. This article discusses the spectrum of ultrasound features of arthritides seen in rheumatoid arthritis and other connective tissue diseases in adults, such as Sjögren syndrome, lupus erythematosus, dermatomyositis, polymyositis, and juvenile idiopathic arthritis. Ultrasound findings in spondyloarthritis, osteoarthritis, and crystal-induced diseases are presented. Ultrasound-guided interventions in patients with arthritis are listed, and the advantages and disadvantages of ultrasound are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Ultrasound-guided plantar fascia release technique: a retrospective study of 46 feet.

    PubMed

    Vohra, Praveen K; Japour, Christopher J

    2009-01-01

    Ultrasound-guided plantar fascia release offers the surgeon clear visualization of anatomy at the surgical site. This technique uses small arthroscopic dissecting instruments through a 0.5-cm incision, allowing the surgeon to avoid the larger and more tissue-disruptive incision that is traditionally used for plantar heel spur resection and plantar fascia releases. Forty-one patients (46 feet) were selected for the study. The mean patient age was 47 years. Twenty-nine were considered obese with a body mass index greater than 30 kg/m(2). Patients were functionally and subjectively evaluated 4 weeks after surgery using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Rating Scale. Results from the study show a significant improvement (P = .05 confidence level) 4 weeks postoperatively for the 41 patients (46 feet), compared to their preoperative condition. The mean pretest score was 33.6 (range 10-52); this score improved to 88.0 (range 50-100), 4 weeks postoperatively. There were no postoperative infections or complications. The ultrasound-guided plantar fascia release technique is a practical surgical procedure for the relief of chronic plantar fascia pain because the surgeon is able to clearly visualize the plantar fascia by ultrasound. In addition, there is minimal disruption to surrounding tissue because small instruments are passed through a small 0.5-cm incision. The traditional open method of heel spur surgery, in contrast, uses a larger skin incision of 3 to 5 cm, followed by larger instruments to dissect to the plantar fascia.

  17. Thyroid Nodule Classification in Ultrasound Images by Fine-Tuning Deep Convolutional Neural Network.

    PubMed

    Chi, Jianning; Walia, Ekta; Babyn, Paul; Wang, Jimmy; Groot, Gary; Eramian, Mark

    2017-08-01

    With many thyroid nodules being incidentally detected, it is important to identify as many malignant nodules as possible while excluding those that are highly likely to be benign from fine needle aspiration (FNA) biopsies or surgeries. This paper presents a computer-aided diagnosis (CAD) system for classifying thyroid nodules in ultrasound images. We use deep learning approach to extract features from thyroid ultrasound images. Ultrasound images are pre-processed to calibrate their scale and remove the artifacts. A pre-trained GoogLeNet model is then fine-tuned using the pre-processed image samples which leads to superior feature extraction. The extracted features of the thyroid ultrasound images are sent to a Cost-sensitive Random Forest classifier to classify the images into "malignant" and "benign" cases. The experimental results show the proposed fine-tuned GoogLeNet model achieves excellent classification performance, attaining 98.29% classification accuracy, 99.10% sensitivity and 93.90% specificity for the images in an open access database (Pedraza et al. 16), while 96.34% classification accuracy, 86% sensitivity and 99% specificity for the images in our local health region database.

  18. Treatment of great auricular neuralgia with real-time ultrasound-guided great auricular nerve block

    PubMed Central

    Jeon, Younghoon; Kim, Saeyoung

    2017-01-01

    Abstract Rationale: The great auricular nerve can be damaged by the neck surgery, tumor, and long-time pressure on the neck. But, great auricular neuralgia is very rare condition. It was managed by several medication and landmark-based great auricular nerve block with poor prognosis. Patient concerns: A 25-year-old man presented with a pain in the left lateral neck and auricle. Diagnosis: He was diagnosed with great auricular neuralgia. Interventions: His pain was not reduced by medication. Therefore, the great auricular nerve block with local anesthetics and steroid was performed under ultrasound guidance. Outcomes: Ultrasound guided great auricular nerve block alleviated great auricular neuralgia. Lessons: This medication-resistant great auricular neuralgia was treated by the ultrasound guided great auricular nerve block with local anesthetic agent and steroid. Therefore, great auricular nerve block can be a good treatment option of medication resistant great auricular neuralgia. PMID:28328811

  19. New application system for laser and ultrasonic therapy in endoscopic surgery

    NASA Astrophysics Data System (ADS)

    Desinger, Kai; Helfmann, Juergen; Stein, Thomas; Mueller, Gerhard J.

    1996-12-01

    Flexible acoustic waveguides for selective tissue fragmentation are not yet commercially available. Experimental studies have shown the possibility of transmission of acoustical transients via optical silica glass fibers. The aim of this project is the development of a new endoscopic application system that would enable surgeons to use the laser and the ultrasound technique for therapy simultaneously. The concept of this application system is based on the transmission of laser radiation and ultrasound power via flexible silica glass fibers. Theoretical and experimental results on the feasibility of such an application system for an ultrasonic power delivery system are presented. Piezo-electric transducers are used to provide a high efficiency in generating the ultrasonic power. With reference to the CUSA-technique, a special flexible guiding system has been designed for providing aspiration at the tip and for protection of the fiber. The system transmits via an optical fiber up to 100 Watt Nd:YAG laser radiation. The axial oscillation of the fiber tip is +/- micrometers at a frequency of 27 kHz. First results of in vitro experiments are presented. The parenchymatous cells of liver can be fragmented without destruction of the collagenous matrix. The laser can be optionally used to coagulate bleedings or to cut collagenous tissues in contact. Applications for an acoustical and optical waveguide in ultrasonic surgery are demonstrated. This new approach in developing a first application system for the therapeutical use of laser radiation and power ultrasound in minimal invasive surgery via optical waveguides offers new possibilities in surgery. The laser ultrasonic surgical therapy (LUST) with its thin and flexible applicator provides new working fields especially for neuro or liver surgery. The tip can be bent and thus areas which could not be treated before have now been made accessible. Without changing the instrumentation, the surgeon can use the laser for tissue

  20. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  1. Frequency of operative trauma to anal sphincters: evaluation with endoanal ultrasound.

    PubMed

    Stamatiadis, Apostolos; Konstantinou, Evangelos; Theodosopoulou, Eleni; Mamoura, Konstantinia

    2002-01-01

    Sphincter trauma after anorectal surgery is usually asymptomatic. Frequency of trauma cannot be established with the clinical examination only. The frequency of operative sphincter defects and their correlation with disorders of continence was evaluated with the endoanal ultrasound. This study includes 123 subjects who had undergone anorectal surgery in the past and were examined with endoanal ultrasound for various indications such as continence disorders, recurrent fistula, idiopathic perineal pain, or simple postoperative follow-up. No subjects had isolated external anal sphincter defects. Nineteen of 123 patients (15%) had minor or major continence disorders, 55 patients (45%) had no sphincter defects, 42 (34%) had only internal anal sphincter (IAS) defects, and 26 (21%) had simultaneously external and internal anal sphincter (EAS) defects. The incidence of IAS and EAS trauma after Milligan-Morgan hemorrhoidectomy was 1/18 (5.5%) and 0/18 respectively; after fistula repair, 24/42 (57%) and 12/42 (29%); and after anal dilatation, 13/17 (76%) and 4/17 (24%). Sixteen of 26 patients (62%) with EAS trauma and 51/68 patients (75%) with IAS trauma did not report any disorders of continence. In patients with two or more operations, the frequency of IAS trauma was 74%, 30% for EAS trauma, and 26% for continence disorders.

  2. Endovascular surgery for peripheral arterial occlusive disease. A critical review.

    PubMed Central

    Ahn, S S; Eton, D; Moore, W S

    1992-01-01

    Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents. This field can be defined as a diagnostic and therapeutic discipline that uses catheter-based systems to treat vascular disease. As such, it integrates the subspecialties of vascular surgery, interventional radiology, interventional cardiology, and biomedical engineering for the common purpose of improving arterial hemodynamics. Endovascular surgery offers many potential benefits: long incisions are replaced with a puncture wound, the need for postoperative intensive care is significantly reduced, major cardiac and pulmonary complications from general anesthesia are side stepped, and the dollar savings could be dramatic as the need for intensive care unit and in-hospital stay diminishes. Despite these technological advancements, endovascular surgery is still in its infancy and currently has limited applications. This review provides an updated summary of endovascular surgery today and addresses some of the obstacles still preventing its widespread use. PMID:1385944

  3. Ultrasound visual feedback in articulation therapy following partial glossectomy.

    PubMed

    Blyth, Katrina M; Mccabe, Patricia; Madill, Catherine; Ballard, Kirrie J

    2016-01-01

    Disordered speech is common following treatment for tongue cancer, however there is insufficient high quality evidence to guide clinical decision making about treatment. This study investigated use of ultrasound tongue imaging as a visual feedback tool to guide tongue placement during articulation therapy with two participants following partial glossectomy. A Phase I multiple baseline design across behaviors was used to investigate therapeutic effect of ultrasound visual feedback during speech rehabilitation. Percent consonants correct and speech intelligibility at sentence level were used to measure acquisition, generalization and maintenance of speech skills for treated and untreated related phonemes, while unrelated phonemes were tested to demonstrate experimental control. Swallowing and oromotor measures were also taken to monitor change. Sentence intelligibility was not a sensitive measure of speech change, but both participants demonstrated significant change in percent consonants correct for treated phonemes. One participant also demonstrated generalization to non-treated phonemes. Control phonemes along with swallow and oromotor measures remained stable throughout the study. This study establishes therapeutic benefit of ultrasound visual feedback in speech rehabilitation following partial glossectomy. Readers will be able to explain why and how tongue cancer surgery impacts on articulation precision. Readers will also be able to explain the acquisition, generalization and maintenance effects in the study. Copyright © 2016. Published by Elsevier Inc.

  4. Realization of Combined Diagnosis/Treatment System By Ultrasound Strain Measurement-Based Shear Modulus Reconstruction/Imaging Technique Examples With Application on The New Type Interstitial RF Electromagnetic Wave Thermal Therapy

    DTIC Science & Technology

    2001-10-25

    Righetti, J. Ophir, and J. Hazle, “The feasibility of elastographic visualization of HIFU -induced thermal lesions in soft tissues,” Ultrasound in Med...Review article: High intensity focused ultrasound -potential for cancer treatment,” Br. J. Radiol., vol. 68, pp. 1296-1303, 1995. [17] Watkin NA, G...R.. Ter Haar, S. B. Morris, C. R. J. Woodhouse, “The urological applications of focused ultrasound surgery,” Br. J. Urol., vol. 75 (suppl. 1), pp

  5. Ultrasound Cyclo Plasty in Eyes with Glaucoma.

    PubMed

    Giannaccare, Giuseppe; Sebastiani, Stefano; Campos, Emilio C

    2018-01-26

    Glaucoma is a chronic disease caused by the progressive degeneration of the optical nerve fibers, resulting in decreased visual field that can lead to severe visual impairment, and eventually blindness. This manuscript describes a simple, surgeon-friendly, non-incisional technique, named Ultrasound Cyclo Plasty (UCP), for reducing intraocular pressure (IOP) in glaucoma patients. The technique determines a selective coagulation necrosis of the ciliary body; in addition, the stimulation of supra-choroidal and trans-scleral portions of the uveo-scleral outflow pathway has been recently proposed. UCP shows several technical improvements in ultrasound technology compared to previous techniques, providing more precise focusing on the target zone. The procedure is performed in the operating room under peribulbar anesthesia. Briefly, the coupling cone is put in contact with the eye and the ring probe, that contains six piezoelectric transducers which produce the ultrasound beams, is inserted inside it. Their proper centering over the ocular surface represents a crucial step for the correct targeting of the ciliary body. Sterile balanced salt solution is used to fill the empty spaces to ensure ultrasound acoustic propagation. Surgical treatment consists in the sequential automatic activation of each of the six transducers, for a total duration of less than 3 min. The patient leaves the hospital 1 h after the procedure with the treated eye patched. In the present study, 10 patients with open-angle glaucoma were followed-up during at least 12 months after the procedure. IOP was reduced at each interval compared to pre-operative, as well as the number of hypotensive medications. Twenty percent of patients did not respond to the treatment, and needed subsequent surgery to better control IOP. Treatment tolerability was good, with no cases of hypotony or phthisis. The UCP procedure is simpler, faster, safer, and less invasive than traditional cyclodestructive procedures with

  6. Assessment and classification of fistula-in-ano in patients with Crohn's disease by hydrogen peroxide enhanced transanal ultrasound.

    PubMed

    Sloots, C E; Felt-Bersma, R J; Poen, A C; Cuesta, M A; Meuwissen, S G

    2001-09-01

    Crohn's disease is well known for its perianal complications, among which fistulas-in-ano are the most common abnormalities. Fistulas-in-ano in Crohn's disease tend to be complex and have a high recurrence rate. Therefore the role of surgery is generally more conservative. Hydrogen peroxide enhanced transanal ultrasound has proven superior to physical examination, fistulography, computed tomography, and conventional ultrasound in demonstrating the fistula tract. This study examined the fistula tracks in patients with Crohn's disease. Forty-one patients with Crohn's disease and fistula-in-ano were investigated using physical examination, sondage of the fistula, proctoscopy and transanal ultrasound. Hydrogen peroxide was infused via a small catheter into the fistula. The main track and the ramification of the fistula were classified according to the anatomical Parks' classification. Only 9 (22%) patients had a single inter- or transsphincteric fistula. In 5 (12%) patients a single supra- or extrasphincteric fistula (high fistula) was found, in 14 (34%) more than one fistula track (ramified), and in 13 (32%) an anovaginal fistula. Thus 78% of patients had a surgically difficult to treat fistula. In the ramified fistula the main track follows the Parks' classification, but ramifications can have a bizarre pattern which is not in agreement with this classification. Optimal documentation by means of hydrogen peroxide enhanced transanal ultrasound is therefore mandatory before surgery or before other therapies such as anti-tumor necrosis factor treatment.

  7. WE-H-209-00: Carson/Zagzebski Distinguished Lectureship: Image Guided Ultrasound Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives:more » Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.« less

  8. Ultrasound diagnosis of uterine myomas and complications in pregnancy.

    PubMed

    Exacoustòs, C; Rosati, P

    1993-07-01

    To evaluate myomas for ultrasound-documented size, location, position, and relation to the placenta, and to relate these findings to complications during pregnancy, at delivery, and in the puerperium. Among 12,708 pregnant patients who had ultrasound scans, 492 had uterine myomas. Single myomas were found in 88% of cases and multiple myomas in 12%. The myomas were evaluated for size, number, position, location, relationship to the placenta, and echogenic structure, and the outcome of pregnancy was compared to that of patients in the control group. A statistically significant increased incidence of threatened abortion, threatened preterm delivery, abruptio placentae, and pelvic pain was observed in patients with uterine myomas (P < .001). Abruptio placentae was particularly evident in women with myoma volumes greater than 200 cm3, submucosal location, or superimposition of the placenta. Pelvic pain was related to myoma volume greater than 200 cm3 and ultrasound findings of heterogeneous echo patterns and cystic areas. Mode of delivery, abortion, preterm birth, premature rupture of membranes, and fetal growth did not seem to be affected by the presence of myomas. Thirty-two women with uterine myomas were managed surgically. Thirteen underwent myomectomy during pregnancy. Of these, eight delivered at term and five delivered preterm after the 32nd week of gestation. None of the deliveries were associated with neonatal death. The other 19 patients had surgery at delivery. Nine myomectomies were performed at cesarean delivery. Of these, three were complicated by severe hemorrhage necessitating hysterectomy. Another nine hysterectomies were performed during cesarean and one after vaginal delivery. In addition to myoma size, the ultrasound evaluation of pregnant women with myomas should include position, location, relationship to the placenta, and echogenic structure. These ultrasound findings make it possible to identify women at risk for myoma-related complications and

  9. Ultrasound diagnosis of ectopic pregnancy

    PubMed Central

    2015-01-01

    Abstract Ectopic pregnancy (EP) remains the number one cause of first trimester maternal death. Traditionally, laparoscopy has been the gold standard for diagnosis of EP. The advent of high‐resolution transvaginal scan (TVS) means more clinically stable women with EPs are diagnosed earlier, well before surgery becomes necessary in many cases. Early diagnosis by TVS is therefore potentially life saving and can reduce surgical morbidity by allowing elective surgery or even non‐surgical conservative treatment options. Combining transabdominal and transvaginal scanning confers no benefit over transvaginal scanning alone. Reports that reads “…empty uterus, ectopic pregnancy cannot be excluded” should be a thing of the past. Diagnosis of EP should be based upon the positive identification of an adnexal mass using TVS rather than the absence of an intra‐uterine gestational sac. A systematic approach to scanning the early pregnancy pelvis will diagnose the vast majority of EPs at the initial scan. Ultrasound, and in particular TVS, is fast becoming the new gold standard for diagnosis of all types of EP. In modern management, laparoscopy should be seen as the operative tool of choice while TVS the diagnostic tool of choice. PMID:28191110

  10. In Vitro Investigation of the Individual Contributions of Ultrasound-Induced Stable and Inertial Cavitation in Targeted Drug Delivery.

    PubMed

    Gourevich, Dana; Volovick, Alexander; Dogadkin, Osnat; Wang, Lijun; Mulvana, Helen; Medan, Yoav; Melzer, Andreas; Cochran, Sandy

    2015-07-01

    Ultrasound-mediated targeted drug delivery is a therapeutic modality under development with the potential to treat cancer. Its ability to produce local hyperthermia and cell poration through cavitation non-invasively makes it a candidate to trigger drug delivery. Hyperthermia offers greater potential for control, particularly with magnetic resonance imaging temperature measurement. However, cavitation may offer reduced treatment times, with real-time measurement of ultrasonic spectra indicating drug dose and treatment success. Here, a clinical magnetic resonance imaging-guided focused ultrasound surgery system was used to study ultrasound-mediated targeted drug delivery in vitro. Drug uptake into breast cancer cells in the vicinity of ultrasound contrast agent was correlated with occurrence and quantity of stable and inertial cavitation, classified according to subharmonic spectra. During stable cavitation, intracellular drug uptake increased by a factor up to 3.2 compared with the control. Reported here are the value of cavitation monitoring with a clinical system and its subsequent employment for dose optimization. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. PRospective Imaging of CErvical cancer and neoadjuvant treatment (PRICE) study: role of ultrasound to predict partial response in locally advanced cervical cancer patients undergoing chemoradiation and radical surgery.

    PubMed

    Testa, A C; Ferrandina, G; Moro, F; Pasciuto, T; Moruzzi, M C; De Blasis, I; Mascilini, F; Foti, E; Autorino, R; Collarino, A; Gui, B; Zannoni, G F; Gambacorta, M A; Valentini, A L; Rufini, V; Scambia, G

    2018-05-01

    Chemoradiation-based neoadjuvant treatment followed by radical surgery is an alternative therapeutic strategy for locally advanced cervical cancer (LACC), but ultrasound variables used to predict partial response to neoadjuvant treatment are not well defined. Our goal was to analyze prospectively the potential role of transvaginal ultrasound in early prediction of partial pathological response, assessed in terms of residual disease at histology, in a large, single-institution series of LACC patients triaged to neoadjuvant treatment followed by radical surgery. Between October 2010 and June 2014, we screened 108 women with histologically documented LACC Stage IB2-IVA, of whom 88 were included in the final analysis. Tumor volume, three-dimensional (3D) power Doppler indices and contrast parameters were obtained before (baseline examination) and after 2 weeks of treatment. The pathological response was defined as complete (absence of any residual tumor after treatment) or partial (microscopic and/or macroscopic residual tumor at pathological examination). Complete-response and partial-response groups were compared and receiver-operating characteristics (ROC) curves were generated for ultrasound variables that were statistically significant on univariate analysis to evaluate their diagnostic ability to predict partial pathological response. There was a complete pathological response to neoadjuvant therapy in 40 (45.5%) patients and a partial response in 48 (54.5%). At baseline examination, tumor volume did not differ between the two groups. However, after 2 weeks of neoadjuvant treatment, the tumor volume was significantly greater in patients with partial response than it was in those with complete response (P = 0.019). Among the 3D vascular indices, the vascularization index (VI) was significantly lower in the partial-response compared with the complete-response group, both before and after 2 weeks of treatment (P = 0.037 and P = 0.024, respectively

  12. Contrast-enhanced ultrasound (CEUS) in blunt abdominal trauma

    PubMed Central

    Piccolo, Claudia Lucia; Galluzzo, Michele; Ianniello, Stefania; Sessa, Barbara; Trinci, Margherita

    2016-01-01

    Baseline ultrasound is essential in the early assessment of patients with a huge haemoperitoneum undergoing an immediate abdominal surgery; nevertheless, even with a highly experienced operator, it is not sufficient to exclude parenchymal injuries. More recently, a new ultrasound technique using second generation contrast agents, named contrast-enhanced ultrasound (CEUS) has been developed. This technique allows all the vascular phase to be performed in real time, increasing ultrasound capability to detect parenchymal injuries, enhancing some qualitative findings, such as lesion extension, margins and its relationship with capsule and vessels. CEUS has been demonstrated to be almost as sensitive as contrast-enhanced CT in the detection of traumatic injuries in patients with low-energy isolated abdominal trauma, with levels of sensitivity and specificity up to 95%. Several studies demonstrated its ability to detect lesions occurring in the liver, spleen, pancreas and kidneys and also to recognize active bleeding as hyperechoic bands appearing as round or oval spots of variable size. Its role seems to be really relevant in paediatric patients, thus avoiding a routine exposure to ionizing radiation. Nevertheless, CEUS is strongly operator dependent, and it has some limitations, such as the cost of contrast media, lack of panoramicity, the difficulty to explore some deep regions and the poor ability to detect injuries to the urinary tract. On the other hand, it is timesaving, and it has several advantages, such as its portability, the safety of contrast agent, the lack to ionizing radiation exposure and therefore its repeatability, which allows follow-up of those traumas managed conservatively, especially in cases of fertile females and paediatric patients. PMID:26607647

  13. Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.

    PubMed

    Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J

    2010-09-01

    Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.

  14. Comparison of Endoanal Ultrasound with Clinical Diagnosis in Anal Fistula Assessment.

    PubMed

    Sirikurnpiboon, Siripong; Phadhana-anake, Oradee; Awapittaya, Burin

    2016-02-01

    Anal fistula anatomy and its relationship with anal sphincters are important factors influencing the results of surgical management. Pre-operative definitions of fistulous track(s) and the internal opening play a primary role in minimizing damage to the sphincters and recurrence of the fistula. To evaluate the relative accuracy of digital examination and endoanal ultrasound for pre-operative assessment of anal fistula by comparing operative findings. A retrospective review was conducted of all patients with anal fistula admitted to the surgical unit between May 2008 and May 2012. Physical examination and hydrogen peroxide-enhanced endoanal ultrasound (utilising a 10 MHz endoprobe, HITACHI: EUB-7500), were performed in 142 consecutive patients. Results were matched with surgical features to establish their accuracy in preoperative anal fistula assessment. A total of 142 patients (107 men, 35 women), 28 of whom had had previous surgery, were included in the study. Their mean age was 40 (range 18-71) years and their mean BMI was 26.37 (range 17.30-36.11) kg/m². The majority of the fistulas were transphincteric (90.4%) and the rest were intersphincteric (9.6%). The accuracy rates of clinical examination and endoanal ultrasound were 55.63 and 95.07 percent (p < 0.01), respectively. Endoanal ultrasound is superior to digital examination for pre-operative classification of anal fistula

  15. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    NASA Astrophysics Data System (ADS)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  16. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria.

    PubMed

    Miller, G Wilson; Eames, Matthew; Snell, John; Aubry, Jean-François

    2015-05-01

    thermal focus, was also significantly larger for aberration-corrected sonications. There was no significant difference between the sonication results achieved using CT-based and MR-based aberration correction. The authors have demonstrated that transcranial focal heating can be significantly improved in vitro by using UTE MRI to compute skull-induced ultrasound aberration corrections. Their results suggest that UTE MRI could be used instead of CT to implement such corrections on current 0.7 MHz clinical TcMRgFUS devices. The MR image acquisition and segmentation procedure demonstrated here would add less than 15 min to a clinical MRgFUS treatment session.

  17. High intensity focused ultrasound (HIFU).

    PubMed

    Barkin, Jack

    2011-04-01

    Curative treatments for localized prostate cancer, from least invasive to most invasive, include brachytherapy, cryosurgery, three-dimensional conformal radiation therapy, external beam radiation therapy, and radical prostatectomy. A patient with localized, low risk or intermediate risk prostate cancer who is diagnosed at an early age and receives one of these treatments has only an approximately 50% chance of maintaining an undetectable prostate-specific antigen (PSA) level, good spontaneous erections, and total continence by 5 years after treatment. This article discusses transrectal high intensity focused ultrasound (HIFU) treatment of localized prostate cancer using the Sonablate 500 (Focus Surgery, Indianapolis, IN, USA) device, which the author has adopted in favor of the Ablatherm (EDAP, TMS S. A., Lyons, France) device, the other HIFU device approved for use in Canada. Characteristics of the ideal prostate cancer include stage T1-T2b, less than 40 cc in size, and with an anterior-posterior dimension of up to 35 mm high. The anterior zone of the prostate is treated before the posterior zone. The procedure involves 2 to 3 second bursts of ultrasound energy, followed by 3 second cooling cycles. In each treatment lesion, the physician achieves a temperature of 100 C at the focal point. The device allows for real-time visualization of tissue response following the delivery of ultrasound energy. HIFU is a minimally invasive, outpatient treatment for localized prostate cancer that provides similar short term and medium term cure rates and considerably less morbidity and side effects than other treatments. Although the effectiveness of HIFU has not yet been demonstrated in large, long term studies, this treatment option should be discussed with patients who have just been diagnosed with low risk or intermediate risk prostate cancer and desire aggressive, noninvasive, curative therapy, with potentially a lower incidence of side effects compared to conventional

  18. UBM-guided chamber angle surgery for glaucoma management: an experimental study.

    PubMed

    Dietlein, T S; Engels, B F; Jacobi, P C; Krieglstein, G K

    2003-04-01

    The aim of this experimental study was to investigate the potential of ultrasound bimicroscopy (UBM)-guided chamber angle surgery as an alternative or supplement to gonioscopy and intraocular microendoscopy for intraoperative control. In 15 porcine cadaver eyes, mechanical goniopuncture or punctual Er:YAG laser trabecular ablation was performed without operating microscope or gonioscopy, but with real-life ultrasound biomicroscopy monitoring with a 50 MHz transducer. Intraoperative localization of the microsurgical instruments and tissue-instrument contact were qualitatively evaluated. The instruments could be clearly visualized within the chamber angle and disturbing artefacts were only minimal when using mechanically fixed instruments in slow motion. Topographic localization, tissue contact, and penetration depth of the instruments entering the scleral were well illustrated as far as the technical resolution limits of UBM would allow. UBM can be used intraoperatively to monitor the correct manoeuvring of microsurgical instruments in selected ab interno procedures. Some adaptations and further modifications of the technique presented here will be necessary before UBM-guided surgery can be considered for clinical use in humans.

  19. Natural course of undescended testes after inguinoscrotal surgery.

    PubMed

    Meij-deVries, Annebeth; van der Voort, Laszla M; Sijstermans, Karlijn; Meijer, Robert W; van der Plas, Evelyn M; Hack, Wilfried W M

    2013-12-01

    The purpose of the study is to study the natural course of undescended testes after inguinoscrotal surgery. From 2003-2010, 24 boys were observed with 26 undescended testes after inguinoscrotal surgery; 12 had previously undergone inguinal hernia repair and 12 orchidopexy. Spontaneous descent was awaited and (re-)orchidopexy would only be performed in case of non-descent at puberty. The boys were assessed annually for testis position and for testis volume as measured by ultrasound. At the end of the study period, 19 testes had reached scrotal position; of these, 13 (68%) had descended spontaneously and 6 (32%) had been (re-)orchidopexied. No difference was found in the rate of spontaneous descent after previous orchidopexy or inguinal hernia repair (P=0.419). Spontaneous descent of undescended testes after inguinoscrotal surgery occurs regularly. In this study, it was observed in two out of every three cases. © 2013.

  20. Can the Contrast-Enhanced Ultrasound Washout Rate Be Used to Predict Microvascular Invasion in Hepatocellular Carcinoma?

    PubMed

    Zhu, Wei; Qing, Xiachuan; Yan, Feng; Luo, Yan; Li, Yongzhong; Zhou, Xiang

    2017-08-01

    The objective of this study was to investigate use of the washout rate of hepatocellular carcinoma on contrast-enhanced ultrasound (CEUS) for pre-operative determination of the presence of microvascular invasion. The study included 271 patients who underwent liver resection for hepatocellular carcinoma between April 2008 and December 2012, and were examined with contrast-enhanced ultrasound before surgery. Patients were followed up at 3-mo intervals for 3 y. Four washout patterns were classified according to the start time of washout: rapid, portal, delayed and slow. Rapid washout, presence of two or more tumors and tumor size ≥5 cm were identified as independent pre-operative predictors of microvascular invasion on multivariate analysis. Recurrence rates for patients with none, one, two or three predictors were 22.6%, 34.7%, 57.6% and 75.0%, respectively. In combination with tumor number and tumor size, contrast-enhanced ultrasound washout rate may have a role in identifying hepatocellular carcinoma patients with microvascular invasion. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Ultrasound in Space Medicine

    NASA Technical Reports Server (NTRS)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  2. Continuous spinal anaesthesia versus ultrasound-guided combined psoas compartment-sciatic nerve block for hip replacement surgery in elderly high-risk patients: a prospective randomised study.

    PubMed

    Aksoy, Mehmet; Dostbil, Aysenur; Ince, Ilker; Ahiskalioglu, Ali; Alici, Hacı Ahmet; Aydin, Ali; Kilinc, Osman Ozgur

    2014-01-01

    Our aim is to compare the hemodynamic effects of combined psoas compartment-sciatic nerve block (PCSNB) with continuous spinal anaesthesia (CSA) in elderly high-risk patients undergoing hip replacement surgery. Seventy patients over the age of 60 with ASA III or IV physical status were randomly allocated to two groups: In the PCSNB group, ultrasound-guided psoas compartment block was performed with modified Winnie technique using 30 mL of 0.25% bupivacaine with 1:200.000 epinephrine (5 μgr/mL) and iliac crest block was performed using the same local anaesthetic solution (5 mL). All patients in the PCSNB group needed continuing infusion of propofol (2 mg/kg/h) during operation. In the CSA group, CSA was performed in the L3-L4 interspaced with the patient in lateral decubitus position using 2.5 mg of isobaric bupivacaine 0.5%. When sensory block was not reached to the level of T12 within 10 minutes in the CSA group, additional 2.5 mg of isobaric bupivacaine 0.5% was administered through the catheter at 5-min intervals by limiting the total dose of 15 mg until a T12 level of the sensory block was achieved. The PCSNB group had significantly higher mean arterial blood pressure values at the beginning of surgery and at 5(th), 10(th) and 20(th) minutes of surgery compared to the CSA group (P = 0.038, P = 0.029, P = 0.012, P = 0.009 respectively). There were no significant differences between groups in terms of heart rate and peripheral oxygen saturation values during surgery and the postoperative period (P >0.05). Arterial hypotension required ephedrine was observed in 13 patients in the CSA and 4 patients in the PCSNB group (P =0.012). CSA and PCSNB produce satisfactory quality of anaesthesia in elderly high-risk patients with fewer hemodynamic changes in PCSNB cases compared with CSA cases. Australian New Zealand Clinical Trials Registry: ACTRN12614000658617, Registered 24 June 2014.

  3. Treatment of localized abscesses induced by methicillin-resistant Staphylococcus aureus (MRSA) using MRgFUS: First in vivo results

    NASA Astrophysics Data System (ADS)

    Rieck, Birgit; Curiel, Laura; Mougenot, Charles; Zhang, Kunyan; Pichardo, Samuel

    2012-11-01

    Background. In the present work we study the therapeutic effect of focused ultrasound on localized abscess induced by methicillin-resistant Staphylococcus aureus (MRSA). MRSA is a major nosocomial pathogen in health-care facilities. The people, particularly those who are immunocompromised are prone to develop infectious sites that often are non-responsive to regular treatments. Because of its capability to induce a rise of temperature at a very precise location, the use of focused ultrasound represents a considerable opportunity to propose a new therapy for MRSA-related infections. Methods. A 50μL subcutaneous injection of MRSA strain USA 400 bacteria at a concentration of 7×103/μL was made on the left thigh of BALB/c mice and an abscess of 6±2 mm-length formed after 48hrs. A transducer operating at 3 MHz with a focal length of 50mm and diameter of 32mm was used to treat the abscess. The focal point was positioned 2mm under the skin at the abscess center. Forty-eight hours after injection 4 ultrasound exposures of 9s-each were applied to each abscess under Magnetic Resonance-guidance. Each exposure was followed by a 1 min pause. Real-time estimation of change of temperature was done using a communication toolbox (matMRI) developed in our laboratory. Three experimental groups of 6 animals each were tested: moderate temperature (MT), high temperature (HT) and control. MT and HT groups reached, respectively, 55°C and 65°C at end of exposure. Effectiveness of the treatment was assessed by culturing bacteria of the treated abscess 1 and 4 days after treatment. Spleen samples were cultured to test for septicemia. Results. Macroscopic evaluation of treated abscess indicated a diminution of external size of abscess 1d after treatment. Treatment did not cause open wounds. Bacteria counting 1 day after treatment was 0.7±1.1 × 105, 0.5±0.7 × 105 and 1.1±2.3 × 105 CFU/μl for MT, HT and control groups, respectively; for the 4-day end point, the count was 0.6±0.6

  4. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    PubMed

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  5. Stem-cell-activated organ following ultrasound exposure: better transplant option for organ transplantation.

    PubMed

    Wang, Sen; Li, Yu; Ji, Ying-Chang; Lin, Chang-Min; Man, Cheng; Zheng, Xiao-Xuan

    2010-01-01

    Although doctors try their best to protect transplants during surgery, there remain great challenges for the higher survival rate and less rejection of transplants after organ transplantation. Growing evidence indicates that the stem cells could function after injury rather than aging, implying that suitable injury may activate the stem cells of damaged organs. Furthermore, it has been revealed that stem cells can be used to induce tolerance in transplantation and the ultrasound has great biological effects on organs. Basing on these facts, we hypothesize that the stem cells within the transplants can be activated by ultrasound with high-frequency and medium-intensity. Therefore, the stem-cell-activated organs (SCAO) can be derived, and the SCAO will be better transplant option for organ transplantation. We postulate the ultrasound can change the molecular activity and/or quantity of the stem cells, the membrane permeability, the cell-cell junctions, and their surrounding microenvironments. As a result, the stem cells are activated, and the SCAO will acquire more regenerative capacity and less rejection. In the paper, we also discuss the process, methods and models for verifying the theory, and the consequences. We believe the theory may provide a practical method for the clinical application of the ultrasound and stem cells in organ transplantation.

  6. Duplex ultrasound surveillance after carotid artery endarterectomy.

    PubMed

    Al Shakarchi, Julien; Lowry, Danielle; Nath, Jay; Khawaja, Aurangzaib Z; Inston, Nicholas; Tiwari, Alok

    2016-06-01

    After carotid endarterectomy (CEA), patients have been regularly followed up by duplex ultrasound imaging. However, the evidence for long-term follow-up is not clear, especially if the results from an early duplex scan are normal. This study assessed and systematically reviewed the evidence base for long-term surveillance after CEA and a normal early scan. Electronic databases were searched for studies assessing duplex surveillance after CEA in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The primary outcome for this study was the incidence of restenosis after a normal early scan. The secondary outcome was the number of reinterventions after a normal early scan. The review included seven studies that reported 2317 procedures. Of those patients with a normal early scan, 2.8% (95% confidence interval, 0.7%-6%) developed a restenosis, and 0.4% (95% confidence interval, 0%-0.9%) underwent a reintervention for their restenosis during the follow-up period. This review confirms that routine postoperative duplex ultrasound surveillance after CEA is not necessary if the early duplex scan is normal. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Sterile working in ultrasonography: the use of dedicated ultrasound covers and sterile ultrasound gel.

    PubMed

    Marhofer, Peter; Fritsch, Gerhard

    2015-01-01

    Ultrasound is currently an important tool for diagnostic and interventional procedures. Ultrasound imaging provides significant advantages as compared to other imaging methods. The widespread use of ultrasound also carries the risk of drawbacks such as cross-infections. A large body of literature reports this possibly life-threatening side effect and specific patient populations are particularly at risk (e.g., neonates). Various methods of ultrasound probe disinfection are described; however, none of the mechanical or chemical probe disinfection procedures is optimal and, in particular, disinfection with high concentration of alcohol might be associated with ultrasound probe damage. The preparation of ultrasound probes with dedicated probe covers is a useful alternative for sterile working conditions. One ultrasound probe cover discussed in this paper is directly glued on to the ultrasound probe without the use of ultrasound coupling gel. By the use of sterile ultrasound coupling gel at the outer surface, additional effects on aseptic working conditions can be obtained.

  8. The intraoperative use of ultrasound facilitates significantly the arthroscopic debridement of calcific rotator cuff tendinitis.

    PubMed

    Sabeti, M; Schmidt, M; Ziai, P; Graf, A; Nemecek, E; Schueller-Weidekamm, C

    2014-05-01

    During arthroscopy, the localization of calcific deposit in patients suffering from calcifying tendinitis can be demanding and time consuming, frequently using ionizing radiation. Intraoperative ultrasound has been recently promoted, facilitating deposit localization and reducing radiation dose. In this prospective, randomized, controlled and clinical observer-blinded pilot trial, 20 patients with calcific tendinitis were operated. In group I, the deposit was localized conventionally. In group II, the deposit was localized using intraoperative ultrasound. The needle punctures to detect the deposit and operation times were noted. Patients were postoperatively evaluated after 2 and 6 weeks and 9 months. In group II, the needle punctures to detect the deposit were significantly lower than in group I (p < 0.0001). Operation time to localize the deposit was also significantly less in group II (p < 0.033). In both groups, patients improved significantly with increased shoulder function (p < 0.0001) and decreased pain (p < 0.0001) 2 weeks and 9 months (p < 0.001) after surgery. The difference between the groups was not significant. Excellent radiological findings were obtained in both groups after 9 months. Intraoperative US significantly facilitates the detection of calcific deposits during arthroscopic debridement by speeding up surgery and reducing the number of needle punctures. Hence, we have changed our method of detecting calcific deposits intraoperatively from fluoroscopy to ultrasound.

  9. Effect of pulsed ultrasound in combination with gentamicin on bacterial killing of biofilms on bone cements in vivo

    PubMed Central

    Ensing, G.T.; Roeder, B.L.; Nelson, J.L.; van Horn, J.R.; van der Mei, H.C.; Busscher, H.J.; Pitt, W.G.

    2008-01-01

    Aim The aim of this study is to investigate whether pulsed ultrasound in combination with gentamicin yields increased killing of bacterial biofilms on bone cements in vivo. Methods and Results Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with E. coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement disks loaded with gentamicin were used, and in one group unloaded bone cement disks in combination with systemically administered gentamicin were used. Pulsed ultrasound with a mean acoustic intensity of 167 mW cm−2 and a maximum acoustic intensity of 500 mW cm−2 was applied from 24 h till 72 h post surgery on one of the two implanted disks. After euthanization, the bacteria removed from the disk were quantified. Application of ultrasound, combined with gentamicin, reduced the biofilm in all three groups varying between 58 to 69% compared to the negative control. Ultrasound proved to be safe with respect to creating skin lesions. Conclusions Ultrasound resulted in an tendency of improved efficacy of gentamicin, either applied locally or systemically. Significance and impact of Study This study implies that ultrasound could improve the prevention of infection, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice. PMID:16108785

  10. A Necrotizing Fasciitis Fake Out on Point-of-Care Ultrasound-Watch the Shadow.

    PubMed

    Thom, Christopher; Warlaumont, Mary

    2017-04-01

    Point-of-care ultrasound has an increasing role in characterizing soft-tissue infections and has been described previously in the evaluation of necrotizing fasciitis (NF). The identification of air within the soft tissues can be very suggestive of NF in the correct clinical context. A 78-year-old male presented to the emergency department with extensive lower-extremity redness and edema. A point-of-care ultrasound revealed hyperechoic areas within the soft tissues consistent with air, and the patient was taken to surgery and found to have NF. A 60-year-old female presented to the emergency department with physical examination findings consistent with severe cellulitis and associated sepsis. A point-of-care ultrasound revealed hyperechoic areas within the soft tissue that were very similar to the prior case. An emergent surgical consultation was placed due to concern for soft-tissue air and NF. However, these hyperechoic areas were found to be subcutaneous calcifications on subsequent imaging. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Air within the soft tissue is easy to identify on point-of-care ultrasound and can expedite surgical evaluation in cases of suspected NF. Calcifications can mimic the appearance of air on ultrasound and the distinction between these objects can often be made based on the echotexture of the posterior acoustic shadow. Attention to the posterior acoustic shadow can facilitate correct identification of various structures and pathologies in a variety of clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Intraoperative endoscopic ultrasound guidance for laparoscopic excision of invisible symptomatic deep intramural myomas.

    PubMed

    Urman, Bulent; Boza, Aysen; Ata, Baris; Aksu, Sertan; Arslan, Tonguc; Taskiran, Cagatay

    2018-01-01

    The aim of this study was to evaluate the feasibility of intraoperative endoscopic ultrasound guidance for excision of symptomatic deep intramural myomas that are not otherwise visible at laparoscopy. Seventeen patients with symptomatic deep intramural myomas who underwent laparoscopic myomectomy with intraoperative endoscopic ultrasound guidance were followed up and reported. All myomas were removed successfully. The endometrium was breached in one patient. All patients were relieved of their symptoms and three patients presenting with infertility conceived. There were no short- or long-term complications associated with the procedure. One patient who had multiple myomas necessitated intravenous iron treatment prior to discharge. Laparoscopic removal of small symptomatic deep intramural myomas is facilitated by the use of intraoperative endoscopic ultrasound that enables exact localisation and correct placement of the serosal incision. Impact statement What is already known on this subject: When the myoma is symptomatic, compressing the endometrium, does not show serosal protrusion and is not amenable to hysteroscopic resection, laparoscopic surgery may become challenging. What do the results of this study add: The use of intraoperative endoscopic ultrasound under these circumstances may facilitate the procedure by accurate identification of the myoma and correct placement of the serosal incision. What are the implications of these findings for clinical practice and/or further research: Intraoperative ultrasound should be more oftenly used to accurately locate deep intramural myomas to the end of making laparoscopy feasible and possibly decreasing recurrence by facilitating removal of otherwise unidentifiable disease.

  12. Usefulness of ultrasound for the diagnosis of pyogenic flexor tenosynovitis: A prospective single-center study of 57 cases.

    PubMed

    Jardin, E; Delord, M; Aubry, S; Loisel, F; Obert, L

    2018-04-01

    Pyogenic flexor tenosynovitis (PFT) is a functional emergency in hand surgery; however, its diagnosis can be difficult to make. It should always be considered when a patient presents with an inflamed finger. The goal of this study was to investigate the usefulness of ultrasound in the diagnosis of early PFT. Seventy-three patients with suspected pyogenic flexor tenosynovitis were candidates for the study. Since the diagnosis of PFT was obvious in 16 patients, they were excluded from the study and immediately underwent surgery. The remaining 57 patients underwent a clinical examination by a senior surgeon, a blood test for C-reactive protein levels and an ultrasound (US). The US results were compared to the intraoperative findings if the patients were operated or to the clinical outcome in non-operated patients. Seventeen patients had the US diagnosis of PFT confirmed intraoperatively. In 10 patients, the US diagnosis of PFT was not confirmed intraoperatively. In 29 other patients, the diagnosis of PFT was ruled out by US; they all had good outcomes after being treated with antibiotics. In one patient for whom the diagnosis of PFT had been ruled out by US, PFT was actually present. Ultrasound had 94% sensitivity, 65% specificity, 63% positive predictive value, and 95% negative predictive value. Ultrasound is useful as a diagnostic tool for managing early PFT thanks to its excellent negative predictive value and specificity. This objective examination complements the surgeon's subjective clinical examination. Copyright © 2018 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  13. Perioperative optimal blood pressure as determined by ultrasound tagged near infrared spectroscopy and its association with postoperative acute kidney injury in cardiac surgery patients.

    PubMed

    Hori, Daijiro; Hogue, Charles; Adachi, Hideo; Max, Laura; Price, Joel; Sciortino, Christopher; Zehr, Kenton; Conte, John; Cameron, Duke; Mandal, Kaushik

    2016-04-01

    Perioperative blood pressure management by targeting individualized optimal blood pressure, determined by cerebral blood flow autoregulation monitoring, may ensure sufficient renal perfusion. The purpose of this study was to evaluate changes in the optimal blood pressure for individual patients, determined during cardiopulmonary bypass (CPB) and during early postoperative period in intensive care unit (ICU). A secondary aim was to examine if excursions below optimal blood pressure in the ICU are associated with risk of cardiac surgery-associated acute kidney injury (CSA-AKI). One hundred and ten patients undergoing cardiac surgery had cerebral blood flow monitored with a novel technology using ultrasound tagged near infrared spectroscopy (UT-NIRS) during CPB and in the first 3 h after surgery in the ICU. The correlation flow index (CFx) was calculated as a moving, linear correlation coefficient between cerebral flow index measured using UT-NIRS and mean arterial pressure (MAP). Optimal blood pressure was defined as the MAP with the lowest CFx. Changes in optimal blood pressure in the perioperative period were observed and the association of blood pressure excursions (magnitude and duration) below the optimal blood pressure [area under the curve (AUC) < OptMAP mmHgxh] with incidence of CSA-AKI (defined using Kidney Disease: Improving Global Outcomes criteria) was examined. Optimal blood pressure during early ICU stay and CPB was correlated (r = 0.46, P < 0.0001), but was significantly higher in the ICU compared with during CPB (75 ± 8.7 vs 71 ± 10.3 mmHg, P = 0.0002). Thirty patients (27.3%) developed CSA-AKI within 48 h after the surgery. AUC < OptMAP was associated with CSA-AKI during CPB [median, 13.27 mmHgxh, interquartile range (IQR), 4.63-20.14 vs median, 6.05 mmHgxh, IQR 3.03-12.40, P = 0.008], and in the ICU (13.72 mmHgxh, IQR 5.09-25.54 vs 5.65 mmHgxh, IQR 1.71-13.07, P = 0.022). Optimal blood pressure during CPB and in the ICU was correlated. Excursions

  14. Endoscopic ultrasound

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/007646.htm Endoscopic ultrasound To use the sharing features on this page, please enable JavaScript. Endoscopic ultrasound is a type of imaging test. It is ...

  15. Comparison of ultrasound guided transversus abdominis plane block versus local wound infiltration for post operative analgesia in patients undergoing gynaecological surgery under general anaesthesia.

    PubMed

    Ranjit, S; Shrestha, S K

    2014-01-01

    Transversus abdominis plane block has been recently developed as a part of multimodal post operative analgesic techniques. We compared the analgesic efficacy of this technique with local bupivacaine infiltration in patients undergoing gynaecological surgeries with pfannenstiel incision and lower midline incision under general anaesthesia. To evaluate the efficacy of ultrasound guided transversus abdominis plane block for postoperative analgesia. Patients were randomly allocated to three groups: control group (n=15), transversus abdominis plane block group (n=15), who received bilateral transversus abdominis plane blockwith 0.25% bupivacaine, and local infiltration group (n=15), who received local wound infiltration with 0.25% bupivacaine at the end of surgery. All patients received intramuscular diclofenac 12 hourly and intravenous tramadol SOS in the postoperative period. Visual analogue scores for pain were assessed at 1,2,4,8,12 and 24 hours postoperatively and these were compared between the three groups. Average tramadol consumption in 24 hours were also compared among the three groups. Data were subjected to univariate ANOVA test and chi-square test. Level of significance was set at 0.05. Visual analogue scores were significantly less in transversus abdominis plane block group and effect lasted up to 12 hours at rest postoperatively and 8 hours during cough and movement. Bilateral Transversus abdominis plane block was effective in reducing postoperative pain scores for 8 to 12 hours postoperatively. This block was also successful in reducing postoperative opioid requirement.

  16. Preoperative prediction of lymph node metastasis and deep stromal invasion in women with invasive cervical cancer: prospective multicenter study using 2D and 3D ultrasound.

    PubMed

    Pálsdóttir, K; Fischerova, D; Franchi, D; Testa, A; Di Legge, A; Epstein, E

    2015-04-01

    To determine how various objective two-dimensional (2D) and three-dimensional (3D) ultrasound parameters allow prediction of deep stromal tumor invasion and lymph node involvement, in comparison to subjective ultrasound assessment, in women scheduled for surgery for cervical cancer. This was a prospective multicenter trial including 104 women with cervical cancer at FIGO Stages IA2-IIB, verified histologically. Patients scheduled for surgery underwent a preoperative ultrasound examination. The value of various 2D (size, color score) and 3D (volume, vascular indices) ultrasound parameters was compared to that of subjective assessment in the prediction of deep stromal tumor invasion and lymph node involvement. Histology obtained from radical hysterectomy or trachelectomy and pelvic lymphadenectomy was considered as the gold standard for assessment. All women underwent pelvic lymphadenectomy, with 99 (95%) undergoing subsequent radical surgery; five underwent only pelvic lymphadenectomy because of the presence of a positive sentinel lymph node. Women with deep stromal invasion or lymph node involvement had significantly larger tumors (diameter and volume) but there was no correlation with vascular indices measured on 3D ultrasound. Subjective evaluation was superior (AUC, 0.93; sensitivity, 90.5%; specificity, 97.2%) in the prediction of deep stromal invasion when compared to any objective measurement technique, with maximal tumor diameter at 20.5-mm cut-off (AUC, 0.83; sensitivity, 90.5%; specificity, 61.1%) and 3D tumor volume at 9.1-mm(3) cut-off (AUC, 0.85; sensitivity, 79.4%; specificity, 83.3%) providing the best performance among the objective parameters. Both subjective assessment and objective measurements were poorly predictive of lymph node involvement. In women with cervical cancer, subjective ultrasound evaluation allowed better prediction of deep stromal invasion than did objective measurements; however, neither subjective evaluation nor objective

  17. Reproducibility of ECG-gated ultrasound diameter assessment of small abdominal aortic aneurysms.

    PubMed

    Bredahl, K; Eldrup, N; Meyer, C; Eiberg, J E; Sillesen, H

    2013-03-01

    No standardised ultrasound procedure to obtain reliable growth estimates for abdominal aortic aneurysms (AAA) is currently available. We investigated the feasibility and reproducibility of a novel approach controlling for a combination of vessel wall delineation and cardiac cycle variation. Prospective comparative study. Consecutive patients (N = 27) with an AAA, attending their 6-month control as part of a medical treatment trial, were scanned twice by two ultrasound operators. Then, all ultrasound recordings were transferred to a core facility and analysed by a third person. The AAA diameter was determined in four different ways: from the leading edge of adventitia on the anterior wall to either the leading edge of the adventitia (method A) or leading edge of the intima (method B) on the posterior wall, with both measurements performed in systole and diastole. Inter-operator reproducibility was ± 3 mm for all methods applied. There was no difference in outcome between methods A and B; likewise, end-diastolic measurement did not improve reproducibility in preference to peak-systolic measurement. The use of a standardised ultrasound protocol including ECG-gating and subsequent off-line reading with minute calliper placement reduces variability. This may be of use in developing protocols to better detect even small AAA growth rates during clinical trials. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Ultrasound-guided hydrostatic reduction of intussusception with saline: Safe and effective.

    PubMed

    Karadağ, Çetin Ali; Abbasoğlu, Latif; Sever, Nihat; Kalyoncu, Meltem Kaba; Yıldız, Abdullah; Akın, Melih; Candan, Mustafa; Dokucu, Ali İhsan

    2015-09-01

    The study was undertaken to assess the efficacy of ultrasound-guided saline enema in reducing intussusception and to determine the role of age and duration of symptoms on this event. The case records of patients who were treated for intussusception at our institutions over the past 10 years were retrospectively analyzed. A total of 419 patients were treated for intussusception and 375 of them were included into the study. Patients were excluded if they had symptoms and signs of acute abdominal disease and required surgery as an initial treatment. Hydrostatic reduction was successful in 313 of the 375 patients (83.46%). The procedure-related complication rate was nil. There were 29 episodes of recurrences in 23 patients, and recurrence rates did not differ between patients who responded to hydrostatic reduction and those who required surgery. Younger age [median (range); 11 months (3-108 months) vs. 20 months (1-180 months); p<0.05], rectal bleeding (p<0.01) and long duration of symptoms [mean (range); 1.95 days (1-7 days) vs. 1.44 days (1-10 days); p<0.01] were significantly associated with failed hydrostatic reduction. Ultrasound-guided hydrostatic reduction is an easy, safe and effective method for the treatment of intussusception in the absence of acute abdominal findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Comparison of the analgesic efficacy of ultrasound-guided rectus sheath block and local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children.

    PubMed

    Uchinami, Yuka; Sakuraya, Fumika; Tanaka, Nobuhiro; Hoshino, Koji; Mikami, Eri; Ishikawa, Taro; Fujii, Hitomi; Ishikawa, Takehiko; Morimoto, Yuji

    2017-05-01

    Ultrasound-guided rectus sheath block and local anesthetic infiltration are the standard options to improve postoperative pain for children undergoing surgery with a midline incision. However, there is no study comparing the effect of ultrasound-guided rectus sheath block with local anesthetic infiltration for children undergoing laparoscopic surgery. The aim of this trial was to compare the onset of ultrasound-guided rectus sheath block with that of local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children. We performed an observer-blinded, randomized, prospective trial. Enrolled patients were assigned to either an ultrasound-guided rectus sheath block group or a local anesthetic infiltration group. The ultrasound-guided rectus sheath block group (n = 17) received ultrasound-guided rectus sheath block with 0.2 ml·kg -1 of 0.375% ropivacaine per side in the posterior rectus sheath compartment. The local anesthetic infiltration group (n = 17) received local anesthetic infiltration with 0.2 ml·kg -1 of 0.75% ropivacaine. The Face, Legs, Activity, Cry, and Consolability (FLACC) pain scores were recorded at 0, 30, 60 min after arrival at the postanesthesia care unit. Of the 37 patients enrolled in this study, 34 completed the study protocol. A significant difference in the pain scale between the ultrasound-guided rectus sheath block group and local anesthetic infiltration group was found at 0 min (median: 0, interquartile range [IQR]: 0-1.5, vs median: 1, IQR 0-5, confidence interval of median [95% CI]: 0-3, P = 0.048), but no significant difference was found at 30 min (median: 1, IQR: 0-4 vs median: 6, IQR: 0-7, 95% CI: 0-5, P = 0.061), or 60 min (median: 0, IQR: 0-2 vs median: 1, IQR: 0-3, 95% CI: -1 to 1, P = 0.310). No significant difference was found in anesthesia time between the ultrasound-guided rectus sheath block and local anesthetic infiltration groups. No procedure-related complications were observed in either group

  20. High-flow vascular malformation treatment using ultrasound-guided laser combined with polidocanol sclerotherapy.

    PubMed

    Zhang, Yan; Zhou, Ping; Li, Lan; Li, Jia-le

    2015-07-01

    The current treatment for vascular malformations includes surgery, sclerotherapy, and embolization. However, each method has its limitations, such as recurrence, complications, scarring, and radiation exposure. Therefore, identifying an effective, minimally invasive treatment that reduces lesion recurrence is particularly important. We describe in detail a patient who received treatment with ultrasound-guided laser interruption of feeding vessels combined with polidocanol sclerotherapy after the recurrence of forearm high-flow vascular malformation.

  1. Ultrasound to video registration using a bi-plane transrectal probe with photoacoustic markers

    NASA Astrophysics Data System (ADS)

    Cheng, Alexis; Kang, Hyun Jae; Zhang, Haichong K.; Taylor, Russell H.; Boctor, Emad M.

    2016-03-01

    Modern surgical scenarios typically provide surgeons with additional information through fusion of video and other imaging modalities. To provide this information, the tools and devices used in surgery must be registered together with interventional guidance equipment and surgical navigation systems. In this work, we focus explicitly on registering ultrasound with a stereo camera system using photoacoustic markers. Previous work has shown that photoacoustic markers can be used in this registration task to achieve target registration errors lower than the current available systems. Photoacoustic markers are defined as a set of non-collinear laser spots projected onto some surface. They can be simultaneously visualized by a stereo camera system and an ultrasound transducer because of the photoacoustic effect. In more recent work, the three-dimensional ultrasound volume was replaced by images from a single ultrasound image pose from a convex array transducer. The feasibility of this approach was demonstrated, but the accuracy was lacking due to the physical limitations of the convex array transducer. In this work, we propose the use of a bi-plane transrectal ultrasound transducer. The main advantage of using this type of transducer is that the ultrasound elements are no longer restricted to a single plane. While this development would be limited to prostate applications, liver and kidney applications are also feasible if a suitable transducer is built. This work is demonstrated in two experiments, one without photoacoustic sources and one with. The resulting target registration error for these experiments were 1.07mm±0.35mm and 1.27mm+/-0.47mm respectively, both of which are better than current available navigation systems.

  2. 76 FR 43119 - Medical Devices; General and Plastic Surgery Devices; Classification of the Focused Ultrasound...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-20

    ... and it is identified as a device using focused ultrasound to produce localized, mechanical motion... labeling includes warnings related to patient reaction in terms of pain and information to user in terms of observable skin reactions that are known to be precursors to the potential thermal adverse effects...

  3. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  4. American Institute of Ultrasound in Medicine

    MedlinePlus

    ... Ultrasound Pediatric Ultrasound Point-of-Care Ultrasound Sonography Therapeutic Ultrasound Ultrasound in Global Health Ultrasound in Medical Education CME Center CME Tracker Annual Convention Journal Tests ...

  5. Ultrasound-guided medical thoracoscopy in the absence of pleural effusion.

    PubMed

    Marchetti, Giampietro; Valsecchi, Alberto; Indellicati, Davide; Arondi, Sabrina; Trigiani, Marco; Pinelli, Valentina

    2015-04-01

    Medical thoracoscopy (MT) is a diagnostic and therapeutic procedure that permits the study of the pleural space. The presence of pleural adhesions is the most important contraindication to performing MT. Lesions of the pleura in absence of pleural effusion are usually studied in video-assisted thoracoscopic surgery (VATS) with preoperative ultrasound evaluation. No data are available about ultrasound-guided MT in the absence of pleural effusion. From January 2007 to June 2013, 622 consecutive MTs were performed under ultrasound guidance without inducing a pneumothorax. A retrospective cohort of 29 patients affected by pleural diseases without fluid was reviewed. The fifth or sixth intercostal spaces along the midaxillary line with a good echographic "sliding sign" and normal appearance of the pleural line were chosen as the entry site. The pleural cavity was explored, and biopsies were performed. The mean age of the patient cohort was 62.8 years; there were 20 male patients and nine female patients. Pleural adherences were avoided, and adequate number of pleural biopsies were performed. No parenchymal lung injuries, bleeding, or hematoma occurred. Seventeen patients had a completely free pleural cavity, four patients had a single pleural adhesion, and eight had multiple pleural adhesions; in all cases, however, endoscopic exploration was possible and biopsy specimens were adequate. The most frequent histopathologic diagnosis was malignant pleural mesothelioma. We have shown that thoracic ultrasound accurately identifies intrathoracic adhesions and, in experienced hands, can guide MT access, replacing the VATS approach, even in the complete absence of pleural effusion.

  6. Minimum effective volume of mepivacaine for ultrasound-guided supraclavicular block

    PubMed Central

    Song, Jae Gyok; Kang, Bong Jin; Park, Kee Keun

    2013-01-01

    Background The aim of this study was to estimate the minimum effective volume (MEV) of 1.5% mepivacaine for ultrasound-guided supraclavicular block by placing the needle near the lower trunk of brachial plexus and multiple injections. Methods Thirty patients undergoing forearm and hand surgery received ultrasound-guided supraclavicular block with 1.5% mepivacaine. The initial volume of local anesthetic injected was 24 ml, and local anesthetic volume for the next patient was determined by the response of the previous patient. The next patient received a 3 ml higher volume in the case of the failure of the previous case. If the previous block was successful, the next volume was 3 ml lower. MEV was estimated by the Dixon and Massey up and down method. MEV in 95, 90, and 50% of patients (MEV95, MEV90, and MEV50) were calculated using probit transformation and logistic regression. Results MEV95 of 1.5% mepivacaine was 17 ml (95% confidence interval [CI], 13-42 ml), MEV90 was 15 ml (95% CI, 12-34 ml), and MEV50 was 9 ml (95% CI, 4-12 ml). Twelve patients had a failed block. Three patients received general anesthesia. Nine patients could undergo surgery with sedation only. Only one patient showed hemi-diaphragmatic paresis. Conclusions MEV95 was 17 ml, MEV90 was 15 ml, and MEV50 was 9 ml. However, needle location near the lower trunk of brachial plexus and multiple injections should be performed. PMID:23904937

  7. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    NASA Astrophysics Data System (ADS)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  8. Novel automatic detection of pleura and B-lines (comet-tail artifacts) on in vivo lung ultrasound scans

    NASA Astrophysics Data System (ADS)

    Moshavegh, Ramin; Hansen, Kristoffer Lindskov; Møller Sørensen, Hasse; Hemmsen, Martin Christian; Ewertsen, Caroline; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt

    2016-04-01

    This paper presents a novel automatic method for detection of B-lines (comet-tail artifacts) in lung ultrasound scans. B-lines are the most commonly used artifacts for analyzing the pulmonary edema. They appear as laser-like vertical beams, which arise from the pleural line and spread down without fading to the edge of the screen. An increase in their number is associated with presence of edema. All the scans used in this study were acquired using a BK3000 ultrasound scanner (BK Ultrasound, Denmark) driving a 192-element 5:5 MHz wide linear transducer (10L2W, BK Ultrasound). The dynamic received focus technique was employed to generate the sequences. Six subjects, among those three patients after major surgery and three normal subjects, were scanned once and Six ultrasound sequences each containing 50 frames were acquired. The proposed algorithm was applied to all 300 in-vivo lung ultrasound images. The pleural line is first segmented on each image and then the B-line artifacts spreading down from the pleural line are detected and overlayed on the image. The resulting 300 images showed that the mean lateral distance between B-lines detected on images acquired from patients decreased by 20% in compare with that of normal subjects. Therefore, the method can be used as the basis of a method of automatically and qualitatively characterizing the distribution of B-lines.

  9. Determining the origin of superficial venous reflux in the groin with duplex ultrasound and implications for varicose vein surgery.

    PubMed

    Zollmann, Paul; Zollmann, Christine; Zollmann, Philipp; Veltman, Juergen; Kerzig, Dennis; Doerler, Martin; Stücker, Markus

    2017-01-01

    The purpose of this paper was to describe patterns of superficial reflux in the groin with respect to the terminal valve (TV), which is located at the saphenous opening to the common femoral vein, the great saphenous vein, and its tributary veins. This study included 2019 legs with chronic venous insufficiency that received endoluminal varicose vein treatment because of varicosities with insufficiency of the saphenofemoral junction (SFJ). In a preoperative duplex ultrasound investigation of the superficial vein system, reflux after provocation in the SFJ, great saphenous vein, cranial veins (superficial external pudendal vein, superficial epigastric vein, superficial circumflex iliac vein), and anterior and posterior accessory saphenous veins was recorded and classified on the basis of the origin of reflux. In 1348 legs (66.8%), the reflux had its origin exclusively in the common femoral vein. In 170 legs (8.4%), the reflux had its origin in the common femoral and cranial veins. In 430 legs (21.3%), the insufficiency was due to saphenocranial reflux only. In 71 legs (3.5%), the origin of reflux could not be determined. Reflux in the SFJ does not involve the TV in 24.8% of the legs, implying that routine high ligation and ablation close to the TV might be overtreatment in these patients. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Ultrasound-guided microinjection into the mouse forebrain in utero at E9.5.

    PubMed

    Pierfelice, Tarran J; Gaiano, Nicholas

    2010-11-13

    In utero survival surgery in mice permits the molecular manipulation of gene expression during development. However, because the uterine wall is opaque during early embryogenesis, the ability to target specific parts of the embryo for microinjection is greatly limited. Fortunately, high-frequency ultrasound imaging permits the generation of images that can be used in real time to guide a microinjection needle into the embryonic region of interest. Here we describe the use of such imaging to guide the injection of retroviral vectors into the ventricular system of the mouse forebrain at embryonic day (E) 9.5. This method uses a laparotomy to permit access to the uterine horns, and a specially designed plate that permits host embryos to be bathed in saline while they are imaged and injected. Successful surgeries often result in most or all of the injected embryos surviving to any subsequent time point of interest (embryonically or postnatally). The principles described here can be used with slight modifications to perform injections into the amnionic fluid of E8.5 embryos (thereby permitting infection along the anterior posterior extent of the neural tube, which has not yet closed), or into the ventricular system of the brain at E10.5/11.5. Furthermore, at mid-neurogenic ages (~E13.5), ultrasound imaging can be used direct injection into specific brain regions for viral infection or cell transplantation. The use of ultrasound imaging to guide in utero injections in mice is a very powerful technique that permits the molecular and cellular manipulation of mouse embryos in ways that would otherwise be exceptionally difficult if not impossible.

  11. Intraoperative adaptation and visualization of preoperative risk analyses for oncologic liver surgery

    NASA Astrophysics Data System (ADS)

    Hansen, Christian; Schlichting, Stefan; Zidowitz, Stephan; Köhn, Alexander; Hindennach, Milo; Kleemann, Markus; Peitgen, Heinz-Otto

    2008-03-01

    Tumor resections from the liver are complex surgical interventions. With recent planning software, risk analyses based on individual liver anatomy can be carried out preoperatively. However, additional tumors within the liver are frequently detected during oncological interventions using intraoperative ultrasound. These tumors are not visible in preoperative data and their existence may require changes to the resection strategy. We propose a novel method that allows an intraoperative risk analysis adaptation by merging newly detected tumors with a preoperative risk analysis. To determine the exact positions and sizes of these tumors we make use of a navigated ultrasound-system. A fast communication protocol enables our application to exchange crucial data with this navigation system during an intervention. A further motivation for our work is to improve the visual presentation of a moving ultrasound plane within a complex 3D planning model including vascular systems, tumors, and organ surfaces. In case the ultrasound plane is located inside the liver, occlusion of the ultrasound plane by the planning model is an inevitable problem for the applied visualization technique. Our system allows the surgeon to focus on the ultrasound image while perceiving context-relevant planning information. To improve orientation ability and distance perception, we include additional depth cues by applying new illustrative visualization algorithms. Preliminary evaluations confirm that in case of intraoperatively detected tumors a risk analysis adaptation is beneficial for precise liver surgery. Our new GPU-based visualization approach provides the surgeon with a simultaneous visualization of planning models and navigated 2D ultrasound data while minimizing occlusion problems.

  12. Anthropomorphic cardiac ultrasound phantom.

    PubMed

    Smith, S W; Rinaldi, J E

    1989-10-01

    A new phantom is described which simulates the human cardiac anatomy for applications in ultrasound imaging, ultrasound Doppler, and color-flow Doppler imaging. The phantom consists of a polymer left ventricle which includes a prosthetic mitral and aortic valve and is connected to a mock circulatory loop. Aerated tap water serves as a blood simulating fluid and ultrasound contrast medium within the circulatory loop. The left ventricle is housed in a Lexan ultrasound visualization chamber which includes ultrasound viewing ports and acoustic absorbers. A piston pump connected to the visualization chamber by a single port pumps degassed water within the chamber which in turn pumps the left ventricle. Real-time ultrasound images and Doppler studies measure flow patterns through the valves and within the left ventricle.

  13. Hot topics in biomedical ultrasound: ultrasound therapy and its integration with ultrasonic imaging

    NASA Astrophysics Data System (ADS)

    Everbach, E. Carr

    2005-09-01

    Since the development of biomedical ultrasound imaging from sonar after WWII, there has been a clear divide between ultrasonic imaging and ultrasound therapy. While imaging techniques are designed to cause as little change as possible in the tissues through which ultrasound propagates, ultrasound therapy typically relies upon heating or acoustic cavitation to produce a desirable therapeutic effect. Concerns over the increasingly high acoustic outputs of diagnostic ultrasound scanners prompted the adoption of the Mechanical Index (MI) and Thermal Index (TI) in the early 1990s. Therapeutic applications of ultrasound, meanwhile, have evolved from deep tissue heating in sports medicine to include targeted drug delivery, tumor and plaque ablation, cauterization via high intensity focused ultrasound (HIFU), and accelerated dissolution of blood clots. The integration of ultrasonic imaging and therapy in one device is just beginning, but the promise of improved patient outcomes is balanced by regulatory and practical impediments.

  14. Ultrasound Assessment of Human Meniscus.

    PubMed

    Viren, Tuomas; Honkanen, Juuso T; Danso, Elvis K; Rieppo, Lassi; Korhonen, Rami K; Töyräs, Juha

    2017-09-01

    The aim of the present study was to evaluate the applicability of ultrasound imaging to quantitative assessment of human meniscus in vitro. Meniscus samples (n = 26) were harvested from 13 knee joints of non-arthritic human cadavers. Subsequently, three locations (anterior, center and posterior) from each meniscus were imaged with two ultrasound transducers (frequencies 9 and 40 MHz), and quantitative ultrasound parameters were determined. Furthermore, partial-least-squares regression analysis was applied for ultrasound signal to determine the relations between ultrasound scattering and meniscus integrity. Significant correlations between measured and predicted meniscus compositions and mechanical properties were obtained (R 2  = 0.38-0.69, p < 0.05). The relationship between conventional ultrasound parameters and integrity of the meniscus was weaker. To conclude, ultrasound imaging exhibited a potential for evaluation of meniscus integrity. Higher ultrasound frequency combined with multivariate analysis of ultrasound backscattering was found to be the most sensitive for evaluation of meniscus integrity. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Effect of pulsed ultrasound in combination with gentamicin on bacterial viability in biofilms on bone cements in vivo.

    PubMed

    Ensing, G T; Roeder, B L; Nelson, J L; van Horn, J R; van der Mei, H C; Busscher, H J; Pitt, W G

    2005-01-01

    The aim of this study is to investigate whether pulsed ultrasound (US) in combination with gentamicin yields a decreased viability of bacteria in biofilms on bone cements in vivo. Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with an Escherichia coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement discs loaded with gentamicin, freshly prepared and aged were used, and in one group unloaded bone cement discs in combination with systemically administered gentamicin. Pulsed ultrasound with a frequency of 28.48 kHz and a maximum acoustic intensity of 500 mW cm(-2) was applied continuously from 24 h till 72 h postsurgery on one of the two implanted discs. After euthanization and removal of the bacteria from the discs, the number of viable bacteria were quantified and skin samples were analysed for histopathological examination. Application of ultrasound, combined with gentamicin, reduced the viability of the biofilms in all three groups varying between 58 and 69% compared with the negative control. Histopathological examinations showed no skin lesions. Ultrasound resulted in a tendency of improved efficacy of gentamicin, either applied locally or systemically. Usage of ultrasound in this model proved to be safe. This study implies that ultrasound could improve the prevention of infection immediately after surgery, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice.

  16. Improved visualization of intracranial vessels with intraoperative coregistration of rotational digital subtraction angiography and intraoperative 3D ultrasound.

    PubMed

    Podlesek, Dino; Meyer, Tobias; Morgenstern, Ute; Schackert, Gabriele; Kirsch, Matthias

    2015-01-01

    Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment. Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient). Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative rotational digital subtraction angiography.

  17. Ultrasound follow-up of infantile hypertrophic pyloric stenosis (IHPS) during conservative therapy: ultrasound findings as criteria for diagnosis and cure.

    PubMed

    Miura, Sachiko; Haku, Eijitsu; Hirai, Toshiko; Marugami, Nagaaki; Itoh, Takahiro; Tanaka, Takehiro; Kichikawa, Kimihiko; Ohishi, Hajime

    2008-06-01

    During conservative therapy of infantile hypertrophic pyloric stenosis (IHPS) with atropine sulfate, there are many patients who do not achieve normal values of pyloric wall thickness and canal length even though they are clinically cured (vomiting has ceased); an objective criterion for cure has not yet been established. The aim of this study was to examine whether the appearance of pyloric wall stratification can be used as a criterion for cure. Twenty infants with IHPS who were treated conservatively were enrolled. Two of them ultimately required surgery. Ultrasound examinations were done serially and the pyloric wall thickness and canal length were measured. The echogenicity of the pyloric wall and the presence of wall stratification were noted. On admission, all infants satisfied the ultrasound criteria for IHPS and had a heterogeneous pyloric wall without stratification. With conservative therapy, symptoms disappeared, the pyloric wall thickness and the canal length gradually decreased, the echogenicity gradually became homogeneous and hypoechoic, and wall stratification appeared (in most cases before the pyloric wall thickness and the canal length had normalized). The absence of wall stratification suggests that cellular interstitial changes, such as edema or inflammation, are present in the pyloric wall in the acute stage. Pyloric wall stratification was absent during the acute stage, but it appeared after initiation of treatment but before the pyloric wall thickness and the canal length had normalized. The presence of pyloric wall stratification can be used as a criterion for cure; the absence of wall stratification can be added to ultrasound diagnostic criteria for IHPS.

  18. Comparison of translabial three-dimensional ultrasound with magnetic resonance imaging for measurement of levator hiatal biometry at rest.

    PubMed

    Vergeldt, T F M; Notten, K J B; Stoker, J; Fütterer, J J; Beets-Tan, R G; Vliegen, R F A; Schweitzer, K J; Mulder, F E M; van Kuijk, S M J; Roovers, J P W R; Kluivers, K B; Weemhoff, M

    2016-05-01

    To compare translabial three-dimensional (3D) ultrasound with magnetic resonance imaging (MRI) for the measurement of levator hiatal biometry at rest in women with pelvic organ prolapse, and to determine the interobserver reliability between two independent observers for ultrasound and MRI measurements. Data were derived from a multicenter prospective cohort study in which women scheduled for conventional anterior colporrhaphy underwent translabial 3D ultrasound and MRI prior to surgery. Intraclass correlation coefficients (ICCs) were calculated to estimate interobserver reliability between two independent observers and determine the agreement between ultrasound and MRI measurements. Bland-Altman plots were created to assess the agreement between ultrasound and MRI measurements. Data from 139 women from nine hospitals were included in the study. The interobserver reliability of ultrasound assessment at rest, during Valsalva maneuver and during contraction and of MRI assessment at rest were moderate or good. The agreement between ultrasound and MRI for the measurement of levator hiatal biometry at rest was moderate, with ICCs of 0.52 (95%CI, 0.32-0.66) for levator hiatal area, 0.44 (95%CI, 0.21-0.60) for anteroposterior diameter and 0.44 (95%CI, 0.22-0.60) for transverse diameter. Levator hiatal biometry measurements were statistically significantly larger on MRI than on translabial 3D ultrasound. The agreement between translabial 3D ultrasound and MRI for measurement of the levator hiatus at rest in women with pelvic organ prolapse was only moderate. The results of translabial 3D ultrasound and MRI should therefore not be used interchangeably in daily practice or in clinical research. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  19. Transvaginal Drainage of Pelvic Abscesses and Collections Using Transabdominal Ultrasound Guidance.

    PubMed

    Ching, Kevin C; Sumkin, Jules H

    2015-01-01

    Objectives. To evaluate clinical outcomes following transvaginal catheter placement using transabdominal ultrasound guidance for management of pelvic fluid collections. Methods. A retrospective review was performed for all patients who underwent transvaginal catheter drainage of pelvic fluid collections utilizing transabdominal ultrasound guidance between July 2008 and July 2013. 24 consecutive patients were identified and 24 catheters were placed. Results. The mean age of patients was 48.1 years (range = 27-76 y). 88% of collections were postoperative (n = 21), 8% were from pelvic inflammatory disease (n = 2), and 4% were idiopathic (n = 1). Of the 24 patients, 83% of patients (n = 20) had previously undergone a hysterectomy and 1 patient (4%) was pregnant at the time of drainage. The mean volume of initial drainage was 108 mL (range = 5 to 570). Catheters were left in place for an average of 4.3 days (range = 1-17 d). Microbial sampling was performed in all patients with 71% (n = 17) returning a positive culture. All collections were successfully managed percutaneously. There were no technical complications. Conclusions. Transvaginal catheter drainage of pelvic fluid collections using transabdominal ultrasound guidance is a safe and clinically effective procedure. Appropriate percutaneous management can avoid the need for surgery.

  20. The role of intraoperative ultrasound in small renal mass robotic enucleation.

    PubMed

    Gunelli, Roberta; Fiori, Massimo; Salaris, Cristiano; Salomone, Umberto; Urbinati, Marco; Vici, Alexia; Zenico, Teo; Bertocco, Mauro

    2016-12-30

    As a result of the growing evidence on tumor radical resection in literature, simple enucleation has become one of the best techniques associated to robotic surgery in the treatment of renal neoplasia, as it guarantees minimal invasiveness and the maximum sparing of renal tissue, facilitating the use of reduced or zero ischemia techniques during resection. The use of a robotic ultrasound probe represents a useful tool to detect and define tumor location, especially in poorly exophytic small renal mass. A total of 22 robotic enucleations were performed on < 3 cm renal neoplasias (PADUA score 18 Pz 6/7 e 4 Pz 8) using a 12-5 MHz robotic ultrasound probe (BK Drop-In 8826). Once kidney had been isolated from the adipose capsule at the site of the neoplasia (2), the exact position of the lesion could be easily identified in all cases (22/22), even for mostly endophytic lesions, thanks to the insertion of the ultrasound probe through the assistant port. Images were produced and visualized by the surgeon using the TilePro feature of the DaVinci surgical system for producing a picture-in-picture image on the console screen. The margins of resection were then marked with cautery, thus allowing for speedy anatomical dissection. This reduced the time of ischemia to 8 min (6-13) and facilitated the enucleation technique when performed without clamping the renal peduncle (6/22). No complications due to the use of the ultrasound probe were observed. The use of an intraoperative robotic ultrasound probe has allowed for easier identification of small, mostly endophytic neoplasias, better anatomical approach, shorter ischemic time, reduced risk of pseudocapsule rupture during dissection, and easier enucleation in cases performed without clamping. It is noteworthy that the use of intraoperative ultrasound probe allows mental reconstruction of the tumor through an accurate 3D vision of the hidden field during surgical dissection.

  1. Investigation of optimal method for inducing harmonic motion in tissue using a linear ultrasound phased array--a simulation study.

    PubMed

    Heikkilä, Janne; Hynynen, Kullervo

    2006-04-01

    Many noninvasive ultrasound techniques have been developed to explore mechanical properties of soft tissues. One of these methods, Localized Harmonic Motion Imaging (LHMI), has been proposed to be used for ultrasound surgery monitoring. In LHMI, dynamic ultrasound radiation-force stimulation induces displacements in a target that can be measured using pulse-echo imaging and used to estimate the elastic properties of the target. In this initial, simulation study, the use of a one-dimensional phased array is explored for the induction of the tissue motion. The study compares three different dual-frequency and amplitude-modulated single-frequency methods for the inducing tissue motion. Simulations were computed in a homogeneous soft-tissue volume. The Rayleigh integral was used in the simulations of the ultrasound fields and the tissue displacements were computed using a finite-element method (FEM). The simulations showed that amplitude-modulated sonication using a single frequency produced the largest vibration amplitude of the target tissue. These simulations demonstrate that the properties of the tissue motion are highly dependent on the sonication method and that it is important to consider the full three-dimensional distribution of the ultrasound field for controlling the induction of tissue motion.

  2. Recent Progress of Bypass Surgery to the Dialysis-Dependent Patients with Critical Limb Ischemia

    PubMed Central

    Azuma, Nobuyoshi; Kikuchi, Shinsuke; Okuda, Hiroko; Miyake, Keisuke; Koya, Atsuhiro

    2017-01-01

    According to expansion of dialysis-dependent population, more than half of patients with critical ischemic limbs are dialysis-dependent in Japan. Although patients with end-staged renal disease are well-known as poor life prognosis, well-managed dialysis patients in Japan can survive much longer compared to dialysis patients in the United States and Europe. Therefore, some dialysis patients can enjoy the long-term benefits of bypass surgery. To decide the indication of bypass surgery, patient’s general condition, nutrition status, and vein availability are more important rather than arterial disease anatomy. Ultrasound guided nerve block anesthesia blocking both sciatic and femoral nerve is contributing greatly to quick postoperative recovery of high risk patients. Preoperative ultrasound examination also contribute to not only vein mapping but also find out the graftable segment of artery. The selection of distal target should be decided based on the degree of arterial disease (luminal surface as well as wall calcification), and arterial run-off. Several tips regarding anastomosis to heavily calcified artery have been established including how to create bloodless operative field without arterial clamps. Adequate wound management after bypass surgery is also important. Detection of deep infection such as osteomyelitis and the adequate treatment may avoid major amputation of salvageable limbs. In the era of endovascular treatment, the evidences guiding how to select dialysis patients suitable for bypass surgery are awaiting. (This is a translation of Jpn J Vasc Surg 2017; 26: 33–39.) PMID:29147171

  3. Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.

    PubMed

    Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S

    2014-07-01

    (1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  4. Ultrasound skin tightening.

    PubMed

    Minkis, Kira; Alam, Murad

    2014-01-01

    Ultrasound skin tightening is a noninvasive, nonablative method that allows for energy deposition into the deep dermal and subcutaneous tissue while avoiding epidermal heating. Ultrasound coagulation is confined to arrays of 1-mm(3) zones that include the superficial musculoaponeurotic system and connective tissue. This technology gained approval from the Food and Drug Administration as the first energy-based skin "lifting" device, specifically for lifting lax tissue on the neck, submentum, and eyebrows. Ultrasound has the unique advantage of direct visualization of treated structures during treatment. Ultrasound is a safe and efficacious treatment for mild skin tightening and lifting. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. New technique targeting the C5 nerve root proximal to the traditional interscalene sonoanatomical approach is analgesic for outpatient arthroscopic shoulder surgery.

    PubMed

    Dobie, Katherine H; Shi, Yaping; Shotwell, Matthew S; Sandberg, Warren S

    2016-11-01

    Regional anesthesia and analgesia for shoulder surgery is most commonly performed via interscalene nerve block. We developed an ultrasound-guided technique that specifically targets the C5 nerve root proximal to the traditional interscalene block and assessed its efficacy for shoulder analgesia. Prospective case series. Vanderbilt Bone and Joint Surgery Center. Patients undergoing shoulder arthroscopy at an ambulatory surgery center. Thirty-five outpatient shoulder arthroscopy patients underwent an analgesic nerve block using a new technique where ultrasound visualization of the C5 nerve root served as the primary target at a level proximal to the traditional interscalene approach. The block was performed with 15mL of 0.5% plain ropivicaine. Post anesthesia care unit pain scores, opioid consumption, hand strength, and duration of block were recorded. Cadaver dissection after injection with methylene blue confirmed that the primary target under ultrasound visualization was the C5 nerve root. Pain scores revealed 97% patients had 0/10 pain at arrival to PACU, with 91% having a pain score of 3/10 or less at discharge from PACU. Medical Research Council (MRC) hand strength mean (SD) score was 4.17 (0.92) on a scale of 1-5. The mean (SD) duration of the block was 13.9 (3.5) hours. A new technique for ultrasound-guided blockade at the level of the C5 nerve root proximal to the level of the traditional interscalene block is efficacious for shoulder post-operative pain control. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Matched-pair analyses of resting and dynamic morphology between Monarc and TVT-O procedures by ultrasound.

    PubMed

    Yang, Jenn-Ming; Yang, Shwu-Huey; Huang, Wen-Chen; Tzeng, Chii-Ruey

    2013-07-01

    To determine morphologic differences between Monarc and TVT-O procedures in axial and coronal planes by three- and four-dimensional (3D and 4D) ultrasound. Retrospective chart audits and ultrasound analyses were conducted on 128 women who had undergone either Monarc or TVT-O procedures for urodynamic stress incontinence. Thirty matched pairs of the two successful procedures were randomly selected and compared. Matched variables were age, parity, body mass index, cesarean status, menopausal status, and primary surgeries. Six-month postoperative 3D and 4D ultrasound results obtained at rest, on straining, and during coughing in these 60 women were analyzed. Assessed ultrasound parameters included the axial tape urethral distance (aTUD), axial central urethral echolucent area (aUCEA), axial tape angle (aTA), and coronal tape angle (cTA), all of which were measured at three equidistant points along the tapes. Paired t-tests were used to compare differences in ultrasound parameters between women after the two procedures and a P value <0.004 was considered significant after Bonferroni correction. At rest, women subjected to Monarc procedures had a significantly wider aTA at one-fourth of the tape and a wider cTA at one-, two-, and three-fourths of the tape than did those subjected to TVT-O procedures. There were no significant differences in other resting ultrasound parameters between these two procedures. Additionally, after both procedures women had comparable straining and coughing ultrasound manifestations as well as respective dynamic changes. Despite flatter resting tape angulations in women following Monarc procedures, both Monarc and TVT-O tapes had equivalent dynamic patterns and changes assessed by 4D ultrasound. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Focused Ultrasound Hyperthermia Mediated Drug Delivery Using Thermosensitive Liposomes and Visualized With in vivo Two-Photon Microscopy.

    PubMed

    Santos, Marc A; Goertz, David E; Hynynen, Kullervo

    2017-01-01

    The future of nanomedicines in oncology requires leveraging more than just the passive drug accumulation in tumors through the enhanced permeability and retention effect. Promising results combining mild hyperthermia (HT) with lyso-thermosensitive liposomal doxorubicin (LTSL-DOX) has led to improved drug delivery and potent antitumor effects in pre-clinical studies. The ultimate patient benefit from these treatments can only be realized when robust methods of HT can be achieved clinically. One of the most promising methods of non-invasive HT is the use of focused ultrasound (FUS) with MRI thermometry for anatomical targeting and feedback. MRI-guided focused ultrasound (MRgFUS) is limited by respiratory motion and large blood vessel cooling. In order to translate exciting pre-clinical results to the clinic, novel heating approaches capable of overcoming the limitations on clinical MRgFUS+HT must be tested and evaluated on their ability to locally release drug from LTSL-DOX. Methods: In this work, a new system is described to integrate focused ultrasound (FUS) into a two-photon microscopy (2PM) setting to image the release of drug from LTSL-DOX in real-time during FUS+HT in vivo . A candidate scheme for overcoming the limitations of respiratory motion and large blood vessel cooling during MRgFUS+HT involves applying FUS+HT to 42°C in short ~30s bursts. The spatiotemporal drug release pattern from LTSL-DOX as a result is quantified using 2PM and compared against continuous (3.5min and 20min at 42°C) FUS+HT schemes and unheated controls. Results: It was observed for the first time in vivo that these short duration temperature elevations could produce substantial drug release from LTSL-DOX. Ten 30s bursts of FUS+HT was able to achieve almost half of the interstitial drug concentration as 20min of continuous FUS+HT. There was no significant difference between the intravascular area under the concentration-time curve for ten 30s bursts of FUS+HT and 3.5min of continuous

  8. Interstitial ablation and imaging of soft tissue using miniaturized ultrasound arrays

    NASA Astrophysics Data System (ADS)

    Makin, Inder R. S.; Gallagher, Laura A.; Mast, T. Douglas; Runk, Megan M.; Faidi, Waseem; Barthe, Peter G.; Slayton, Michael H.

    2004-05-01

    A potential alternative to extracorporeal, noninvasive HIFU therapy is minimally invasive, interstitial ultrasound ablation that can be performed laparoscopically or percutaneously. Research in this area at Guided Therapy Systems and Ethicon Endo-Surgery has included development of miniaturized (~3 mm diameter) linear ultrasound arrays capable of high power for bulk tissue ablation as well as broad bandwidth for imaging. An integrated control system allows therapy planning and automated treatment guided by real-time interstitial B-scan imaging. Image quality, challenging because of limited probe dimensions and channel count, is aided by signal processing techniques that improve image definition and contrast. Simulations of ultrasonic heat deposition, bio-heat transfer, and tissue modification provide understanding and guidance for development of treatment strategies. Results from in vitro and in vivo ablation experiments, together with corresponding simulations, will be described. Using methods of rotational scanning, this approach is shown to be capable of clinically relevant ablation rates and volumes.

  9. Ultrasound: Bladder (For Parents)

    MedlinePlus

    ... the computer screen. A technician (sonographer) trained in ultrasound imaging will spread a clear, warm gel on the ... specially trained in reading and interpreting X-ray, ultrasound, and other imaging studies) will interpret the ultrasound results and then ...

  10. Ultrasound: Pelvis (For Parents)

    MedlinePlus

    ... the computer screen. A technician (sonographer) trained in ultrasound imaging will spread a clear, warm gel on the ... specially trained in reading and interpreting X-ray, ultrasound, and other imaging studies) will interpret the ultrasound results and then ...

  11. Ultrasound in regional anaesthesia.

    PubMed

    Griffin, J; Nicholls, B

    2010-04-01

    Ultrasound guidance is rapidly becoming the gold standard for regional anaesthesia. There is an ever growing weight of evidence, matched with improving technology, to show that the use of ultrasound has significant benefits over conventional techniques, such as nerve stimulation and loss of resistance. The improved safety and efficacy that ultrasound brings to regional anaesthesia will help promote its use and realise the benefits that regional anaesthesia has over general anaesthesia, such as decreased morbidity and mortality, superior postoperative analgesia, cost-effectiveness, decreased postoperative complications and an improved postoperative course. In this review we consider the evidence behind the improved safety and efficacy of ultrasound-guided regional anaesthesia, before discussing its use in pain medicine, paediatrics and in the facilitation of neuraxial blockade. The Achilles' heel of ultrasound-guided regional anaesthesia is that anaesthetists are far more familiar with providing general anaesthesia, which in most cases requires skills that are achieved faster and more reliably. To this ends we go on to provide practical advice on ultrasound-guided techniques and the introduction of ultrasound into a department.

  12. Classification and management of gynecomastia: defining the role of ultrasound-assisted liposuction.

    PubMed

    Rohrich, Rod J; Ha, Richard Y; Kenkel, Jeffrey M; Adams, William P

    2003-02-01

    Gynecomastia, or excessive male breast development, has an incidence of 32 to 65 percent in the male population. This condition has important physical and psychological impacts. Advances in elucidating the pathophysiology of gynecomastia have been made, though understanding remains limited. Recommendations for evaluation and workup have varied and are often arbitrary. A diagnostic algorithm is suggested, with emphasis on a comprehensive history, physical examination, and minimizing unnecessary diagnostic testing. Medical management has had limited success; surgical therapy, primarily through excisional techniques, has been the accepted standard. Although effective, excisional techniques subject patients to large, visible scars. Ultrasound-assisted liposuction has recently emerged as a safe and effective method for the treatment of gynecomastia. It is particularly efficient in the removal of the dense, fibrous male breast tissue while offering advantages in minimal external scarring. A new system of classification and graduated treatment is proposed, based on glandular versus fibrous hypertrophy and degree of breast ptosis (skin excess). The authors' series of 61 patients with gynecomastia from 1987 to 2000 at the University of Texas Southwestern Department of Plastic Surgery demonstrated an overall success rate of 86.9 percent using suction-assisted lipectomy (1987 to 1997) and ultrasound-assisted liposuction (1997 to 2000). The authors have found ultrasound-assisted liposuction to be effective in treating most grades of gynecomastia. Excisional techniques are reserved for severe gynecomastia with significant skin excess after attempted ultrasound-assisted liposuction.

  13. Influence of low-intensity pulsed ultrasound on osteogenic tissue regeneration in a periodontal injury model: X-ray image alterations assessed by micro-computed tomography.

    PubMed

    Wang, Yunji; Chai, Zhaowu; Zhang, Yuanyuan; Deng, Feng; Wang, Zhibiao; Song, Jinlin

    2014-08-01

    This study was conducted to evaluate, with micro-computed tomography, the influence of low-intensity pulsed ultrasound on wound-healing in periodontal tissues. Periodontal disease with Class II furcation involvement was surgically produced at the bilateral mandibular premolars in 8 adult male beagle dogs. Twenty-four teeth were randomly assigned among 4 groups (G): G1, periodontal flap surgery; G2, periodontal flap surgery+low-intensity pulsed ultrasound (LIPUS); G3, guided tissue regeneration (GTR) surgery; G4, GTR surgery plus LIPUS. The affected area in the experimental group was exposed to LIPUS. At 6 and 8weeks, the X-ray images of regenerated teeth were referred to micro-CT scanning for 3-D measurement. Bone volume (BV), bone surface (BS), and number of trabeculae (Tb) in G2 and G4 were higher than in G1 and G3 (p<0.05). BV, BS, and Tb.N of the GTR+LIPUS group were higher than in the GTR group. BV, BS, and Tb.N of the LIPUS group were higher than in the periodontal flap surgery group. LIPUS irradiation increased the number, volume, and area of new alveolar bone trabeculae. LIPUS has the potential to promote the repair of periodontal tissue, and may work effectively if combined with GTR. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Effect of modulated ultrasound parameters on ultrasound-induced thrombolysis.

    PubMed

    Soltani, Azita; Volz, Kim R; Hansmann, Doulas R

    2008-12-07

    The potential of ultrasound to enhance enzyme-mediated thrombolysis by application of constant operating parameters (COP) has been widely demonstrated. In this study, the effect of ultrasound with modulated operating parameters (MOP) on enzyme-mediated thrombolysis was investigated. The MOP protocol was applied to an in vitro model of thrombolysis. The results were compared to a COP with the equivalent soft tissue thermal index (TIS) over the duration of ultrasound exposure of 30 min (p < 0.14). To explore potential differences in the mechanism responsible for ultrasound-induced thrombolysis, a perfusion model was used to measure changes in average fibrin pore size of clot before, after and during exposure to MOP and COP protocols and cavitational activity was monitored in real time for both protocols using a passive cavitation detection system. The relative lysis enhancement by each COP and MOP protocol compared to alteplase alone yielded values of 33.69 +/- 12.09% and 63.89 +/- 15.02% in a thrombolysis model, respectively (p < 0.007). Both COP and MOP protocols caused an equivalent significant increase in average clot pore size of 2.09 x 10(-2) +/- 0.01 microm and 1.99 x 10(-2) +/- 0.004 microm, respectively (p < 0.74). No signatures of inertial or stable cavitation were observed for either acoustic protocol. In conclusion, due to mechanisms other than cavitation, application of ultrasound with modulated operating parameters has the potential to significantly enhance the relative lysis enhancement compared to application of ultrasound with constant operating parameters.

  15. What is ultrasound?

    PubMed

    Leighton, Timothy G

    2007-01-01

    This paper is based on material presented at the start of a Health Protection Agency meeting on ultrasound and infrasound. In answering the question 'what is ultrasound?', it shows that the simple description of a wave which transports mechanical energy through the local vibration of particles at frequencies of 20 kHz or more, with no net transport of the particles themselves, can in every respect be misleading or even incorrect. To explain the complexities responsible for this, the description of ultrasound is first built up from the fundamental properties of these local particle vibrations. This progresses through an exposition of the characteristics of linear waves, in order to explain the propensity for, and properties of, the nonlinear propagation which occurs in many practical ultrasonic fields. Given the Health Protection environment which framed the original presentation, explanation and examples are given of how these complexities affect issues of practical importance. These issues include the measurement and description of fields and exposures, and the ability of ultrasound to affect tissue (through microstreaming, streaming, cavitation, heating, etc.). It is noted that there are two very distinct regimes, in terms of wave characteristics and potential for bioeffect. The first concerns the use of ultrasound in liquids/solids, for measurement or material processing. For biomedical applications (where these two processes are termed diagnosis and therapy, respectively), the issue of hazard has been studied in depth, although this has not been done to such a degree for industrial uses of ultrasound in liquids/solids (sonar, non-destructive testing, ultrasonic processing etc.). However, in the second regime, that of the use of ultrasound in air, although the waves in question tend to be of much lower intensities than those used in liquids/solids, there is a greater mismatch between the extent to which hazard has been studied, and the growth in commercial

  16. Quantitative Ultrasound Backscatter for Pulsed Cavitational Ultrasound Therapy—Histotripsy

    PubMed Central

    Wang, Tzu-Yin; Xu, Zhen; Winterroth, Frank; Hall, Timothy L.; Fowlkes, J. Brian; Rothman, Edward D.; Roberts, William W.; Cain, Charles A.

    2011-01-01

    Histotripsy is a well-controlled ultrasonic tissue ablation technology that mechanically and progressively fractionates tissue structures using cavitation. The fractionated tissue volume can be monitored with ultrasound imaging because a significant ultrasound backscatter reduction occurs. This paper correlates the ultrasound backscatter reduction with the degree of tissue fractionation characterized by the percentage of remaining normal-appearing cell nuclei on histology. Different degrees of tissue fractionation were generated in vitro in freshly excised porcine kidneys by varying the number of therapeutic ultrasound pulses from 100 to 2000 pulses per treatment location. All ultrasound pulses were 15 cycles at 1 MHz delivered at 100 Hz pulse repetition frequency and 19 MPa peak negative pressure. The results showed that the normalized backscatter intensity decreased exponentially with increasing number of pulses. Correspondingly, the percentage of normal appearing nuclei in the treated area decreased exponentially as well. A linear correlation existed between the normalized backscatter intensity and the percentage of normal appearing cell nuclei in the treated region. This suggests that the normalized backscatter intensity may be a potential quantitative real-time feedback parameter for histotripsy-induced tissue fractionation. This quantitative feedback may allow the prediction of local clinical outcomes, i.e., when a tissue volume has been sufficiently treated. PMID:19750596

  17. Quantitative ultrasound backscatter for pulsed cavitational ultrasound therapy- histotripsy.

    PubMed

    Wang, Tzu-yin; Xu, Zhen; Winterroth, Frank; Hall, Timothy L; Fowlkes, J Brian; Rothman, Edward D; Roberts, William W; Cain, Charles A

    2009-05-01

    Histotripsy is a well-controlled ultrasonic tissue ablation technology that mechanically and progressively fractionates tissue structures using cavitation. The fractionated tissue volume can be monitored with ultrasound imaging because a significant ultrasound backscatter reduction occurs.This paper correlates the ultrasound backscatter reduction with the degree of tissue fractionation characterized by the percentage of remaining normal-appearing cell nuclei on histology.Different degrees of tissue fractionation were generated in vitro in freshly excised porcine kidneys by varying the number of therapeutic ultrasound pulses from 100 to 2000 pulses per treatment location. All ultrasound pulses were 15 cycles at 1 MHz delivered at 100 Hz pulse repetition frequency and 19 MPa peak negative pressure. The results showed that the normalized backscatter intensity decreased exponentially with increasing number of pulses. Correspondingly, the percentage of normal appearing nuclei in the treated area decreased exponentially as well. A linear correlation existed between the normalized backscatter intensity and the percentage of normal appearing cell nuclei in the treated region. This suggests that the normalized backscatter intensity may be a potential quantitative real-time feedback parameter for histotripsy-induced tissue fractionation. This quantitative feedback may allow the prediction of local clinical outcomes, i.e., when a tissue volume has been sufficiently treated.

  18. Is axillary surgery beneficial for patients with adenoid cystic carcinoma of the breast?

    PubMed

    Welsh, Jessemae L; Keeney, Michael G; Hoskin, Tanya L; Glazebrook, Katrina N; Boughey, Judy C; Shah, Sejal S; Hieken, Tina J

    2017-11-01

    Adenoid cystic carcinoma (ACC) is a rare, typically triple-negative, breast cancer reported to have a favorable prognosis and low rate of nodal metastasis. No consensus guidelines exist for axillary staging and treatment. We identified all patients with ACC evaluated at our institution from January 1994 to August 2016. Patient, tumor, and treatment variables were abstracted and analyzed. We identified 20 pure ACCs (0.13% of all invasive breast cancers) with size range 0.2-4.8 cm, in 19 women, median age 59 years. Preoperative axillary ultrasound was normal in 10/13 women and suspicious in 3/13 who had a subsequent negative lymph node fine needle aspiration (FNA). Fifteen patients (75%) had sentinel lymph node surgery and were pathologically node-negative, while the remaining five had no axillary surgery. With 3.6 years median follow-up (range 0.2-38.6 years), three patients experienced an in-breast recurrence at 2, 16, and 17 years, respectively, while none recurred in regional nodes. We observed no cases of nodal metastasis in 20 consecutive cases of ACC of the breast. Preoperative axillary ultrasound with FNA of suspicious nodes accurately predicted pathologic nodal stage. These data suggest axillary surgery might be omitted safely in patients with pure ACC and a clinically negative axilla. © 2017 Wiley Periodicals, Inc.

  19. Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination.

    PubMed

    Stock, Konrad Friedrich; Klein, Bettina; Steubl, Dominik; Lersch, Christian; Heemann, Uwe; Wagenpfeil, Stefan; Eyer, Florian; Clevert, Dir-Andre

    2015-10-01

    Time savings and clinical accuracy of a new miniature ultrasound device was investigated utilizing comparison with conventional high-end ultrasound instruments. Our objective was to determine appropriate usage and limitations of this diagnostic tool in internal medicine. We investigated 28 patients from the internal-medicine department. Patients were examined with the Acuson P10 portable device and a Sonoline Antares instrument in a cross-over design. All investigations were carried out at the bedside; the results were entered on a standardized report form. The time for the ultrasound examination (transfer time, setting up and disassembly, switching on and off, and complete investigation time) was recorded separately. Mean time for overall examination per patient with the portable ultrasound device was shorter (25.0 ± 4.5 min) than with the high-end machine (29.4 ± 4.4 min; p < 0.001). When measuring the size of liver, spleen, and kidneys, the values obtained differed significantly between portable device and the high-end instrument. In our study, we identified 113 pathological ultrasound findings with the high-end ultrasound machine, while 82 pathological findings (73%) were concordantly detected with the portable ultrasound device. The main diagnostic strengths of the portable device were in the detection of ascites (sensitivity 80%), diagnosis of fatty liver, and identification of severe parenchymal liver damage. The clinical utility of portable ultrasound machines is limited. There will be clinical roles for distinct clinical questions such as detection of ascites or pleural effusion when used by experienced examiners. However, sensitivity in detecting multiple pathologies is not comparable to high-end ultrasound machines.

  20. Are the same tapes really the same? Ultrasound study of laser-cut and mechanically cut TVT-O post-operative behavior.

    PubMed

    Rusavy, Zdenek; Masata, Jaromir; Svabik, Kamil; Hubka, Petr; Zvara, Karel; Martan, Alois

    2017-11-25

    TVT-O production has been modified to laser cutting from mechanical cutting. We compared the behavior of laser and mechanically cut tension-free vaginal tape-obturator (TVT-O) using ultrasound at various time points after surgery. This is a retrospective analysis of clinical and ultrasound data from two previously reported randomized controlled trials with TVT-O. Behavior of mechanically cut TVT-O implanted in January 2007 to November 2009 and laser-cut TVT-O implanted in May 2010 to May 2012 was assessed by ultrasound at day 1, the 2nd week, the 3rd month, and the 1st and 2nd years post-operatively. Bladder neck and tape margins positions were described by coordinates in the orthogonal system calculated from polar coordinates. Tape mobility was measured as a change in the upper and lower tape margin position from rest to maximal Valsalva. Comparison of 2-year subjective and objective surgery outcomes was also performed. In total, 68 mechanically cut and 50 laser-cut TVT-Os were implanted. Follow-up data were available from 49 and 45 women respectively. No differences in any baseline characteristics or bladder neck mobility were observed. Significantly lower tape mobility was observed on day 1 and week 2 after mechanically cut TVT-O, although subsequent mobility was comparable to laser-cut TVT-O. The subjective and objective surgery outcomes were comparable. Although without clinical significance, early postoperative behavior of the mechanically cut and laser-cut TVT-O tapes differs. The less stiff, mechanically-cut TVT-O loosens within 2 weeks of implantation, whereas the stiffer, laser-cut TVT-O keeps its tension.

  1. High-Accuracy Ultrasound Contrast Agent Detection Method for Diagnostic Ultrasound Imaging Systems.

    PubMed

    Ito, Koichi; Noro, Kazumasa; Yanagisawa, Yukari; Sakamoto, Maya; Mori, Shiro; Shiga, Kiyoto; Kodama, Tetsuya; Aoki, Takafumi

    2015-12-01

    An accurate method for detecting contrast agents using diagnostic ultrasound imaging systems is proposed. Contrast agents, such as microbubbles, passing through a blood vessel during ultrasound imaging are detected as blinking signals in the temporal axis, because their intensity value is constantly in motion. Ultrasound contrast agents are detected by evaluating the intensity variation of a pixel in the temporal axis. Conventional methods are based on simple subtraction of ultrasound images to detect ultrasound contrast agents. Even if the subject moves only slightly, a conventional detection method will introduce significant error. In contrast, the proposed technique employs spatiotemporal analysis of the pixel intensity variation over several frames. Experiments visualizing blood vessels in the mouse tail illustrated that the proposed method performs efficiently compared with conventional approaches. We also report that the new technique is useful for observing temporal changes in microvessel density in subiliac lymph nodes containing tumors. The results are compared with those of contrast-enhanced computed tomography. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Improved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound

    PubMed Central

    Podlesek, Dino; Meyer, Tobias; Morgenstern, Ute; Schackert, Gabriele; Kirsch, Matthias

    2015-01-01

    Introduction Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. Methods We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment. Results Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient). Conclusions Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative

  3. Ultrasound Imaging System Video

    NASA Technical Reports Server (NTRS)

    2002-01-01

    In this video, astronaut Peggy Whitson uses the Human Research Facility (HRF) Ultrasound Imaging System in the Destiny Laboratory of the International Space Station (ISS) to image her own heart. The Ultrasound Imaging System provides three-dimension image enlargement of the heart and other organs, muscles, and blood vessels. It is capable of high resolution imaging in a wide range of applications, both research and diagnostic, such as Echocardiography (ultrasound of the heart), abdominal, vascular, gynecological, muscle, tendon, and transcranial ultrasound.

  4. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  5. [Ultrasound findings in rhabdomyolysis].

    PubMed

    Carrillo-Esper, Raúl; Galván-Talamantes, Yazmin; Meza-Ayala, Cynthia Margarita; Cruz-Santana, Julio Alberto; Bonilla-Reséndiz, Luis Ignacio

    Rhabdomyolysis is defined as skeletal muscle necrosis. Ultrasound assessment has recently become a useful tool for the diagnosis and monitoring of muscle diseases, including rhabdomyolysis. A case is presented on the ultrasound findings in a patient with rhabdomyolysis. To highlight the importance of ultrasound as an essential part in the diagnosis in rhabdomyolysis, to describe the ultrasound findings, and review the literature. A 30 year-old with post-traumatic rhabdomyolysis of both thighs. Ultrasound was performed using a Philips Sparq model with a high-frequency linear transducer (5-10MHz), in low-dimensional scanning mode (2D), in longitudinal and transverse sections at the level of both thighs. The images obtained showed disorganisation of the orientation of the muscle fibres, ground glass image, thickening of the muscular fascia, and the presence of anechoic areas. Ultrasound is a useful tool in the evaluation of rhabdomyolysis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  6. A Comparison of Three Different Thick Epinucleus Removal Techniques in Cataract Surgery.

    PubMed

    Hwang, Ho Sik; Lim, Byung-Su; Kim, Man Soo; Kim, Eun Chul

    2017-01-01

    To compare the outcomes of cataract surgery performed with three different types of the epinucleus removal techniques (safe boat, infusion/aspiration (I/A) cannulas, and phacoemulsification tip). Ninety eyes with thick adhesive epinuclei were randomly subdivided into three groups according to epinucleus removal technique: epinucleus floating (safe boat) technique, 30 patients; I/A tip, 30 patients; and phaco tip, 30 patients. Intraoperative measurements included ultrasound time (UST), mean cumulative dissipated ultrasound energy (CDE), and balanced salt solution (BSS) use. Clinical measurements were made preoperatively, and at one day, one month and two months postoperatively, including the best corrected visual acuity (BCVA), the central corneal thickness (CCT), and the endothelial cell count (ECC). Intraoperative measurements showed significantly less UST, CDE, and BSS use in the safe boat group than in the phaco tip groups (p < 0.05). The percentage of endothelial cell loss in the safe boat group was significantly lower than that in the phaco tip groups at two months post-cataract surgery (p < 0.05). The safe boat technique is a safer and more effective epinucleus removal technique than phaco tip techniques in cases with thick epinucleus.

  7. The value of ultrasounds exam correlated with frozen section diagnosis in the breast tumors.

    PubMed

    Venter, Alina; Roşca, Elena; Muţiu, Gabriela; Pirte, Adriana; Roşca, D M

    2010-01-01

    The paper represents a parallel study regarding the harmony between the ultrasounds and the frozen section diagnosis in the breast cancer. We examined at an ultrasounds machine a group of 146 women aged between 16-73-year-old, which came presenting palpable formations at the level of breasts, in the Pelican Medical Centre from Oradea. The suspect lesions were subject to excisional biopsy or surgical intervention. The elements followed at the ultrasounds exam were: echogenicity, echostructure, contour, presence and absence of posterior shadowing, microcalcifiation, orientation of lesion, compressibility, aspect of adjacent structures. Histopathological diagnosis of suspect lesions emphasized malignant lesions in a percentage of 64.86% of cases; the frozen section exam diagnosed invasive ductal carcinoma in 86% of the cases, invasive lobular carcinoma 8%, medullar carcinoma 2%, and benign lesions 4%. The clinical-anatomopathological collaboration is absolutely compulsory for a correct microscopic diagnosis. The ultrasounds modifications separated after the criteria taken into account allow the orientation of diagnosis to malignant-benign. At 14% of the women examined, additional lesions were identified in comparison to those palpated, the ultrasounds having a role in detecting the multifocality and muticentricity of lesions. At 29.05% from the identified lesions, malignant lesions were histopathologically identified. The frozen section diagnosis in the breast cancer allows a rapid diagnosis, correct in high percentage of cases, allowing taking an intra-surgery therapeutic attitude in only one surgical intervention, thus reducing the costs. The anatomopathologist's experience reduces the diagnosis risk in excess and÷or in minus.

  8. The protocol and preliminary baseline survey results of the thyroid ultrasound examination in Fukushima [Rapid Communication].

    PubMed

    Suzuki, Shinichi; Yamashita, Shunichi; Fukushima, Toshihiko; Nakano, Keiichi; Midorikawa, Sanae; Ohtsuru, Akira; Yasumura, Seiji; Hosoya, Mitsunori; Kamiya, Kenji; Shimura, Hiroki; Suzuki, Satoru; Nakamura, Izumi; Abe, Masafumi

    2016-01-01

    After the Fukushima nuclear power plant accident on March 11, 2011, the public of Japan became particularly concerned about the possibility of an increased risk of childhood thyroid cancer, similar to what was observed after the Chernobyl's accident. Due to serious public health perception, there was an urgency to evaluate the baseline levels of childhood thyroid status in Fukushima prefecture. Therefore we have commenced a thyroid ultrasound examination (TUE) survey of the approximately 360,000 pediatric inhabitants (0 to 18 years of age) who lived in Fukushima at the time of the accident in October 2011. The subjects were divided into three categories according to the standardized diagnostic criteria of ultrasound findings. Category A contained the subjects whose TUE findings were intact or benign. Category B were recommended a confirmatory TUE. Category C was recommended an immediate confirmatory TUE. The survey of 40,302 subjects in the first year was completed in March, 2013. There were 40,097 (99.5%), 205 (0.50%) and 0 subjects in categories A, B and C, respectively. Of the 82 category B subjects who underwent fine needle aspiration cytology (FNAC), 12 were diagnosed with a malignant tumor or were suspected to have malignancy. The 12 subjects received thyroid surgery and 11 thyroid cancers and one benign nodule were confirmed histologically after surgery. This is the first large-scaled TUE survey to employ sophisticated ultrasound screening and aim to evaluate the baseline frequency of childhood thyroid nodules and cysts. The results will become the golden standard of future comparative TUE in Fukushima, Japan.

  9. Introducing universal ultrasound screening for developmental dysplasia of the hip doubled the treatment rate.

    PubMed

    Olsen, Stine F; Blom, Hans C; Rosendahl, Karen

    2018-02-01

    There is no evidence on the effect of universal ultrasound screening on developmental dysplasia of the hip. We examined the impact of adding an ultrasound examination to a one examiner clinical screening strategy on treatment, follow-up rates and the number of cases detected late in a low-prevalence population. All eligible babies born at Kongsberg Hospital, Norway, from 1998 to 2006 (n = 4245) underwent both clinical and ultrasound hip examinations within three days of life. Indications for immediate treatment were positive Barlow or Ortolani manoeuvres and, or, sonographic dysplasia. Sonographic immature hips were followed until normalisation. Treatment rates and rates from the 1989 to 1997 prestudy period (n = 3594), including late diagnoses, were collected from hospital records. Treatment was initiated in 90 (2.1%) infants (74 girls), 63 (70%) from birth, compared to 33 (0.9%) during the prestudy period. The follow-up rate did not change (11%). There were two (0.5/1000) and four (1.0/1000) cases detected late, respectively. No one underwent surgery during the first year of life and no avascular necrosis was seen. Adding universal ultrasound to clinical screening performed by the same, experienced paediatrician doubled the treatment rate, without influencing the already low numbers of late cases. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  10. Medical Ultrasound Imaging.

    ERIC Educational Resources Information Center

    Hughes, Stephen

    2001-01-01

    Explains the basic principles of ultrasound using everyday physics. Topics include the generation of ultrasound, basic interactions with material, and the measurement of blood flow using the Doppler effect. (Author/MM)

  11. The role of diagnostic ultrasound as a new diagnostic aid in oral and maxillofacial surgery

    PubMed Central

    Venkataraman, Siva Subramaniyam; Aravind, Ramraj Jayabalan; Kavin, Thangavelu

    2012-01-01

    Only very few studies have been done in the past to evaluate the usefulness and limitations of ultrasonography in oral and maxillofacial surgery. This study, though in an embryonic stage, has been done to bring this technique to limelight and to put forth the importance of its use and limitations in the branch of oral surgery. The purpose of this study was to investigate and study the characteristic pattern of the oral tissues on gray scale ultrasonography and to assess the practical applicability of this new diagnostic technique in diagnosing various tissue pathologies in the field of oral and maxillofacial surgery. PMID:23066231

  12. Perioperative optimal blood pressure as determined by ultrasound tagged near infrared spectroscopy and its association with postoperative acute kidney injury in cardiac surgery patients

    PubMed Central

    Hori, Daijiro; Hogue, Charles; Adachi, Hideo; Max, Laura; Price, Joel; Sciortino, Christopher; Zehr, Kenton; Conte, John; Cameron, Duke; Mandal, Kaushik

    2016-01-01

    OBJECTIVES Perioperative blood pressure management by targeting individualized optimal blood pressure, determined by cerebral blood flow autoregulation monitoring, may ensure sufficient renal perfusion. The purpose of this study was to evaluate changes in the optimal blood pressure for individual patients, determined during cardiopulmonary bypass (CPB) and during early postoperative period in intensive care unit (ICU). A secondary aim was to examine if excursions below optimal blood pressure in the ICU are associated with risk of cardiac surgery-associated acute kidney injury (CSA-AKI). METHODS One hundred and ten patients undergoing cardiac surgery had cerebral blood flow monitored with a novel technology using ultrasound tagged near infrared spectroscopy (UT-NIRS) during CPB and in the first 3 h after surgery in the ICU. The correlation flow index (CFx) was calculated as a moving, linear correlation coefficient between cerebral flow index measured using UT-NIRS and mean arterial pressure (MAP). Optimal blood pressure was defined as the MAP with the lowest CFx. Changes in optimal blood pressure in the perioperative period were observed and the association of blood pressure excursions (magnitude and duration) below the optimal blood pressure [area under the curve (AUC) < OptMAP mmHgxh] with incidence of CSA-AKI (defined using Kidney Disease: Improving Global Outcomes criteria) was examined. RESULTS Optimal blood pressure during early ICU stay and CPB was correlated (r = 0.46, P < 0.0001), but was significantly higher in the ICU compared with during CPB (75 ± 8.7 vs 71 ± 10.3 mmHg, P = 0.0002). Thirty patients (27.3%) developed CSA-AKI within 48 h after the surgery. AUC < OptMAP was associated with CSA-AKI during CPB [median, 13.27 mmHgxh, interquartile range (IQR), 4.63–20.14 vs median, 6.05 mmHgxh, IQR 3.03–12.40, P = 0.008], and in the ICU (13.72 mmHgxh, IQR 5.09–25.54 vs 5.65 mmHgxh, IQR 1.71–13.07, P = 0.022). CONCLUSIONS Optimal blood pressure during

  13. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  14. Intraoperative ultrasound guidance in breast-conserving surgery shows superiority in oncological outcome, long-term cosmetic and patient-reported outcomes: Final outcomes of a randomized controlled trial (COBALT).

    PubMed

    Volders, J H; Haloua, M H; Krekel, N M A; Negenborn, V L; Kolk, R H E; Lopes Cardozo, A M F; Bosch, A M; de Widt-Levert, L M; van der Veen, H; Rijna, H; Taets van Amerongen, A H M; Jóźwiak, K; Meijer, S; van den Tol, M P

    2017-04-01

    The multicenter randomized controlled COBALT trial demonstrated that ultrasound-guided breast-conserving surgery (USS) results in a significant reduction of margin involvement (3.1% vs. 13%) and excision volumes compared to palpation-guided surgery (PGS). The aim of the present study was to determine long term oncological and patient-reported outcomes including quality of life (QoL), together with their progress over time. 134 patients with T1-T2 breast cancer were randomized to USS (N = 65) or PGS (N = 69). Cosmetic outcomes were assessed with the Breast Cancer Conservative Treatment cosmetic results (BCCT.core) software, panel-evaluation and patient self-evaluation on a 4-point Likert-scale. QoL was measured using the EORTC QLQ-C30/-BR23 questionnaire. No locoregional recurrences were reported after mean follow-up of 41 months. Seven patients (5%) developed distant metastatic disease (USS 6.3%, PGS 4.4%, p = 0.466), of whom six died of disease (95.5% overall survival). USS achieved better cosmetic outcomes compared to PGS, with poor outcomes of 11% and 21% respectively, a result mainly attributable to mastectomies due to involved margins following PGS. There was no difference after 1 and 3 years in cosmetic outcome. Dissatisfied patients included those with larger excision volumes, additional local therapies and worse QoL. Patients with poor/fair cosmetic outcomes scored significantly lower on aspects of QoL, including breast-symptoms, body image and sexual enjoyment. By significantly reducing positive margin status and lowering resection volumes, USS improves the rate of good cosmetic outcomes and increases patient-satisfaction. Considering the large impact of cosmetic outcome on QoL, USS has great potential to improve QoL following breast-conserving therapy. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  15. Radio Frequency Ultrasound Time Series Signal Analysis to Evaluate High-intensity Focused Ultrasound Lesion Formation Status in Tissue.

    PubMed

    Mobasheri, Saeedeh; Behnam, Hamid; Rangraz, Parisa; Tavakkoli, Jahan

    2016-01-01

    High-intensity focused ultrasound (HIFU) is a novel treatment modality used by scientists and clinicians in the recent decades. This modality has had a great and significant success as a noninvasive surgery technique applicable in tissue ablation therapy and cancer treatment. In this study, radio frequency (RF) ultrasound signals were acquired and registered in three stages of before, during, and after HIFU exposures. Different features of RF time series signals including the sum of amplitude spectrum in the four quarters of the frequency range, the slope, and intercept of the best-fit line to the entire power spectrum and the Shannon entropy were utilized to distinguish between the HIFU-induced thermal lesion and the normal tissue. We also examined the RF data, frame by frame to identify exposure effects on the formation and characteristics of a HIFU thermal lesion at different time steps throughout the treatment. The results obtained showed that the spectrum frequency quarters and the slope and intercept of the best fit line to the entire power spectrum both increased two times during the HIFU exposures. The Shannon entropy, however, decreased after the exposures. In conclusion, different characteristics of RF time series signal possess promising features that can be used to characterize ablated and nonablated tissues and to distinguish them from each other in a quasi-quantitative fashion.

  16. Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation.

    PubMed

    Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y

    2017-08-01

    To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.

  17. New heights in ultrasound: first report of spinal ultrasound from the international space station.

    PubMed

    Marshburn, Thomas H; Hadfield, Chris A; Sargsyan, Ashot E; Garcia, Kathleen; Ebert, Douglas; Dulchavsky, Scott A

    2014-01-01

    Changes in the lumbar and sacral spine occur with exposure to microgravity in astronauts; monitoring these alterations without radiographic capabilities on the International Space Station (ISS) requires novel diagnostic solutions to be developed. We evaluated the ability of point-of-care ultrasound, performed by nonexpert-operator astronauts, to provide accurate anatomic information about the spine in long-duration crewmembers in space. Astronauts received brief ultrasound instruction on the ground and performed in-flight cervical and lumbosacral ultrasound examinations using just-in-time training and remote expert tele-ultrasound guidance. Ultrasound examinations on the ISS used a portable ultrasound device with real-time communication/guidance with ground experts in Mission Control. The crewmembers were able to obtain diagnostic-quality examinations of the cervical and lumbar spine that would provide essential information about acute or chronic changes to the spine. Spinal ultrasound provides essential anatomic information in the cervical and lumbosacral spine; this technique may be extensible to point-of-care situations in emergency departments or resource-challenged areas without direct access to additional radiologic capabilities. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Preliminary results in large bone segmentation from 3D freehand ultrasound

    NASA Astrophysics Data System (ADS)

    Fanti, Zian; Torres, Fabian; Arámbula Cosío, Fernando

    2013-11-01

    Computer Assisted Orthopedic Surgery (CAOS) requires a correct registration between the patient in the operating room and the virtual models representing the patient in the computer. In order to increase the precision and accuracy of the registration a set of new techniques that eliminated the need to use fiducial markers have been developed. The majority of these newly developed registration systems are based on costly intraoperative imaging systems like Computed Tomography (CT scan) or Magnetic resonance imaging (MRI). An alternative to these methods is the use of an Ultrasound (US) imaging system for the implementation of a more cost efficient intraoperative registration solution. In order to develop the registration solution with the US imaging system, the bone surface is segmented in both preoperative and intraoperative images, and the registration is done using the acquire surface. In this paper, we present the a preliminary results of a new approach to segment bone surface from ultrasound volumes acquired by means 3D freehand ultrasound. The method is based on the enhancement of the voxels that belongs to surface and its posterior segmentation. The enhancement process is based on the information provided by eigenanalisis of the multiscale 3D Hessian matrix. The preliminary results shows that from the enhance volume the final bone surfaces can be extracted using a singular value thresholding.

  19. Ultrasound-guided tendon fenestration versus open-release surgery for the treatment of chronic lateral epicondylosis of the elbow: protocol for a prospective, randomised, single blinded study.

    PubMed

    Lungu, Eugen; Grondin, Philippe; Tétreault, Patrice; Desmeules, François; Cloutier, Guy; Choinière, Manon; Bureau, Nathalie J

    2018-06-09

    Chronic lateral epicondylosis (CLE) of the elbow is a prevalent condition among middle-aged people with no consensus on optimal care management but for which surgery is generally accepted as a second intention treatment. Among conservative treatment options, ultrasound (US)-guided fenestration has shown encouraging results that should be explored before surgery is considered. The primary objective of this study is to compare the efficacy of US-guided fenestration with open-release surgery in patients with failure to improve following a minimum 6 months of conservative treatment. This study protocol entails a two-arm, single-blinded, randomised, controlled design. Sixty-four eligible patients with clinically confirmed CLE will be assigned to either US-guided fenestration or open-release surgery. Fisher's exact test will be used to compare the proportion of patients reporting a change of 11/100 points or more in the Patient Rated Tennis Elbow Evaluation score at 6 months, according to an intention-to-treat analysis. Secondary analyses will compare the two treatment groups in terms of pain and disability, functional limitations at work, pain-free grip strength, medication burden, patients' global impression of change and level of satisfaction at 6 weeks, 3, 6 and 12 months, using mixed linear models for repeated measures or Fisher's exact test, as appropriate. Finally, recursive partitioning analyses will investigate US and elastography parameters as predictors of treatment success at 6 and 12 months. This data will contribute to evidence-based treatment guidelines for CLE and explore the value of imaging biomarkers to improve risk stratification plans and assist clinicians. The study has been approved by the Research Ethics Board of our institution on 23 March 2016 (REB 15.327). In case of important protocol modifications, a new version of the protocol with appropriate amendments will be submitted to the REB for approval. Study results will be published in peer

  20. Cranial Ultrasound/Head Ultrasound

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... by a computer, which in turn creates a real-time picture on the monitor. One or more frames ...

  1. Transvaginal ultrasound (image)

    MedlinePlus

    Transvaginal ultrasound is a method of imaging the genital tract in females. A hand held probe is inserted directly ... vaginal cavity to scan the pelvic structures, while ultrasound pictures are viewed on a monitor. The test ...

  2. Abdominal ultrasound (image)

    MedlinePlus

    Abdominal ultrasound is a scanning technique used to image the interior of the abdomen. Like the X-ray, MRI, ... it has its place as a diagnostic tool. Ultrasound scans use high frequency sound waves to produce ...

  3. Portable bladder ultrasound: an evidence-based analysis.

    PubMed

    2006-01-01

    retention, requiring intermittent catheterization, whereas a PVR urine volume of 100 mL to 150 mL or less is generally considered an acceptable result of bladder training. Urinary retention has been associated with poor outcomes including UTI, bladder overdistension, and higher hospital mortality rates. The standard method of determining PVR urine volumes is intermittent catheterization, which is associated with increased risk of UTI, urethral trauma and discomfort. Portable bladder ultrasound products are transportable ultrasound devices that use automated technology to register bladder volume digitally, including PVR volume, and provide three-dimensional images of the bladder. The main clinical use of portable bladder ultrasound is as a diagnostic aid. Health care professionals (primarily nurses) administer the device to measure PVR volume and prevent unnecessary catheterization. An adjunctive use of the bladder ultrasound device is to visualize the placement and removal of catheters. Also, portable bladder ultrasound products may improve the diagnosis and differentiation of urological problems and their management and treatment, including the establishment of voiding schedules, study of bladder biofeedback, fewer UTIs, and monitoring of potential urinary incontinence after surgery or trauma. To determine the effectiveness and clinical utility of portable bladder ultrasound as reported in the published literature, the Medical Advisory Secretariat used its standard search strategy to retrieve international health technology assessments and English-language journal articles from selected databases. Nonsystematic reviews, nonhuman studies, case reports, letters, editorials, and comments were excluded. Of the 4 included studies that examined the clinical utility of portable bladder ultrasound in the elderly population, all found the device to be acceptable. One study reported that the device underestimated catheterized bladder volume In patients with urology problems, 2 of

  4. Applications for a hybrid operating room in thoracic surgery: from multidisciplinary procedures to --image-guided video-assisted thoracoscopic surgery.

    PubMed

    Terra, Ricardo Mingarini; Andrade, Juliano Ribeiro; Mariani, Alessandro Wasum; Garcia, Rodrigo Gobbo; Succi, Jose Ernesto; Soares, Andrey; Zimmer, Paulo Marcelo

    2016-01-01

    The concept of a hybrid operating room represents the union of a high-complexity surgical apparatus with state-of-the-art radiological tools (ultrasound, CT, fluoroscopy, or magnetic resonance imaging), in order to perform highly effective, minimally invasive procedures. Although the use of a hybrid operating room is well established in specialties such as neurosurgery and cardiovascular surgery, it has rarely been explored in thoracic surgery. Our objective was to discuss the possible applications of this technology in thoracic surgery, through the reporting of three cases. RESUMO O conceito de sala híbrida traduz a união de um aparato cirúrgico de alta complexidade com recursos radiológicos de última geração (ultrassom, TC, radioscopia e/ou ressonância magnética), visando a realização de procedimentos minimamente invasivos e altamente eficazes. Apesar de bem estabelecido em outras especialidades, como neurocirurgia e cirurgia cardiovascular, o uso da sala hibrida ainda é pouco explorado na cirurgia torácica. Nosso objetivo foi discutir as aplicações e as possibilidades abertas por essa tecnologia na cirurgia torácica através do relato de três casos.

  5. [Abdominal ultrasound course an introduction to the ultrasound technique. Physical basis. Ultrasound language].

    PubMed

    Segura-Grau, A; Sáez-Fernández, A; Rodríguez-Lorenzo, A; Díaz-Rodríguez, N

    2014-01-01

    Ultrasound is a non-invasive, accessible, and versatile diagnostic technique that uses high frequency ultrasound waves to define outline the organs of the human body, with no ionising radiation, in real time and with the capacity to visual several planes. The high diagnostic yield of the technique, together with its ease of uses plus the previously mentioned characteristics, has currently made it a routine method in daily medical practice. It is for this reason that the multidisciplinary character of this technique is being strengthened every day. To be able to perform the technique correctly requires knowledge of the physical basis of ultrasound, the method and the equipment, as well as of the human anatomy, in order to have the maximum information possible to avoid diagnostic errors due to poor interpretation or lack of information. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  6. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Value of delayed duplex ultrasound assessment after endothermal ablation of the great saphenous vein.

    PubMed

    Ryer, Evan J; Elmore, James R; Garvin, Robert P; Cindric, Matthew C; Dove, James T; Kekulawela, Stephanie; Franklin, David P

    2016-08-01

    only significant predictor of progression to EHIT on multivariate analysis (P = .007). Based on 2014 United States dollars, the two-ultrasound surveillance paradigm is associated with health care charges of $31,109 per identified delayed venous thromboembolism event. Delayed duplex ultrasound assessment after ETA of the GSV comes with associated health care costs but does yield a significant number of patients with progression to EHIT. Better understanding of the timing, risk factors, and significance of EHIT is needed to cost-effectively care for patients after ETA for varicose veins. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. Incidentally detected non-palpable testicular tumours in adults at scrotal ultrasound: impact of radiological findings on management Radiologic review and recommendations of the ESUR scrotal imaging subcommittee.

    PubMed

    Rocher, Laurence; Ramchandani, Parvati; Belfield, Jane; Bertolotto, Michele; Derchi, Lorenzo E; Correas, Jean Michel; Oyen, Raymond; Tsili, Athina C; Turgut, Ahmet Tuncay; Dogra, Vikram; Fizazi, Karim; Freeman, Simon; Richenberg, Jonathan

    2016-07-01

    The increasing detection of small testicular lesions by ultrasound (US) in adults can lead to unnecessary orchiectomies. This article describes their nature, reviews the available literature on this subject and illustrates some classical lesions. We also suggest recommendations to help characterization and management. The ESUR scrotal imaging subcommittee searched for original and review articles published before May 2015 using the Pubmed and Medline databases. Key words used were 'testicular ultrasound', 'contrast-enhanced sonography', 'sonoelastography', 'magnetic resonance imaging', 'testis-sparing surgery', 'testis imaging', 'Leydig cell tumour', 'testicular cyst'. Consensus was obtained amongst the members of the subcommittee, urologist and medical oncologist. Simple cysts are frequent and benign, and do not require follow up or surgery. Incidentally discovered small solid testicular lesions detected are benign in up to 80 %, with Leydig cell tumours being the most frequent. However, the presence of microliths, macrocalcifications and hypoechoic areas surrounding the nodule are findings suggestive of malignant disease. Asymptomatic small testicular lesions found on ultrasound are mainly benign, but findings such as microliths or hypoechoic regions surrounding the nodules may indicate malignancy. Colour Doppler US remains the basic examination for characterization. The role of newer imaging modalities in characterization is evolving. • Characterization of testicular lesions is primarily based on US examination. • The role of MRI, sonoelastography, contrast-enhanced ultrasound is evolving. • Most small non-palpable testicular lesions seen on ultrasound are benign simple cysts. • Leydig cell tumours are the most frequent benign lesions. • Associated findings like microliths or hypoechoic regions may indicate malignancy.

  9. Mammographic density is the main correlate of tumors detected on ultrasound but not on mammography.

    PubMed

    Häberle, Lothar; Fasching, Peter A; Brehm, Barbara; Heusinger, Katharina; Jud, Sebastian M; Loehberg, Christian R; Hack, Carolin C; Preuss, Caroline; Lux, Michael P; Hartmann, Arndt; Vachon, Celine M; Meier-Meitinger, Martina; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger

    2016-11-01

    Although mammography screening programs do not include ultrasound examinations, some diagnostic units do provide women with both mammography and ultrasonography. This article is concerned with estimating the risk of a breast cancer patient diagnosed in a hospital-based mammography unit having a tumor that is visible on ultrasound but not on mammography. A total of 1,399 women with invasive breast cancer from a hospital-based diagnostic mammography unit were included in this retrospective study. For inclusion, mammograms from the time of the primary diagnosis had to be available for computer-assisted assessment of percentage mammographic density (PMD), as well as Breast Imaging Reporting and Data System (BIRADS) assessment of mammography. In addition, ultrasound findings were available for the complete cohort as part of routine diagnostic procedures, regardless of any patient or imaging characteristics. Logistic regression analyses were conducted to identify predictors of mammography failure, defined as BIRADS assessment 1 or 2. The probability that the visibility of a tumor might be masked at diagnosis was estimated using a regression model with the identified predictors. Tumors were only visible on ultrasound in 107 cases (7.6%). PMD was the strongest predictor for mammography failure, but age, body mass index and previous breast surgery also influenced the risk, independently of the PMD. Risk probabilities ranged from 1% for a defined low-risk group up to 40% for a high-risk group. These findings might help identify women who should be offered ultrasound examinations in addition to mammography. © 2016 UICC.

  10. Comparison between transthoracic lung ultrasound and a clinical method in confirming the position of double-lumen tube in thoracic anaesthesia. A pilot study.

    PubMed

    Álvarez-Díaz, N; Amador-García, I; Fuentes-Hernández, M; Dorta-Guerra, R

    2015-01-01

    To compare the ability of lung ultrasound and a clinical method in the confirmation of a selective bronchial intubation by left double-lumen tube in elective thoracic surgery. A prospective and blind, observational study was conducted in the setting of a university hospital operating room assigned for thoracic surgery. A single group of 105 consecutive patients from a total of 130, were included. After blind intubation, the position of the tube was confirmed by clinical and ultrasound assessment. Finally, the fiberoptic bronchoscopy confirmation as a reference standard was used to confirm the position of the tube. Under manual ventilation, by sequentially clamping the tracheal and bronchial limbs of the tube, clinical confirmation was made by auscultation, capnography, visualizing the chest wall expansion, and perceiving the lung compliance in the reservoir bag. Ultrasound confirmation was obtained by visualizing lung sliding, diaphragmatic movements, and the appearance of lung pulse sign. The sensitivity of the clinical method was 84.5%, with a specificity of 41.1%. The positive and negative likelihood ratio was 1.44 and 0.38, respectively. The sensitivity of the ultrasound method was 98.6%, specificity was 52.9%, with a positive likelihood ratio of 2.10 and a negative likelihood ratio of 0.03. Comparisons between the diagnostic performance of the 2 methods were calculated with McNemar's test. There was a significant difference in sensitivity between the ultrasound method and the clinical method (P=.002). Nevertheless, there was no statistically significant difference in specificity between both methods (P=.34). A p value<.01 was considered statistically significant. Lung ultrasound was superior to the clinical method in confirming the adequate position of the left double-lumen tube. On the other hand, in confirming the misplacement of the tube, differences between both methods could not be ensured. Copyright © 2014 Sociedad Española de Anestesiolog

  11. A motorized ultrasound system for MRI-ultrasound fusion guided prostatectomy

    NASA Astrophysics Data System (ADS)

    Seifabadi, Reza; Xu, Sheng; Pinto, Peter; Wood, Bradford J.

    2016-03-01

    Purpose: This study presents MoTRUS, a motorized transrectal ultrasound system, to enable remote navigation of a transrectal ultrasound (TRUS) probe during da Vinci assisted prostatectomy. MoTRUS not only provides a stable platform to the ultrasound probe, but also allows the physician to navigate it remotely while sitting on the da Vinci console. This study also presents phantom feasibility study with the goal being intraoperative MRI-US image fusion capability to bring preoperative MR images to the operating room for the best visualization of the gland, boundaries, nerves, etc. Method: A two degree-of-freedom probe holder is developed to insert and rotate a bi-plane transrectal ultrasound transducer. A custom joystick is made to enable remote navigation of MoTRUS. Safety features have been considered to avoid inadvertent risks (if any) to the patient. Custom design software has been developed to fuse pre-operative MR images to intraoperative ultrasound images acquired by MoTRUS. Results: Remote TRUS probe navigation was evaluated on a patient after taking required consents during prostatectomy using MoTRUS. It took 10 min to setup the system in OR. MoTRUS provided similar capability in addition to remote navigation and stable imaging. No complications were observed. Image fusion was evaluated on a commercial prostate phantom. Electromagnetic tracking was used for the fusion. Conclusions: Motorized navigation of the TRUS probe during prostatectomy is safe and feasible. Remote navigation provides physician with a more precise and easier control of the ultrasound image while removing the burden of manual manipulation of the probe. Image fusion improved visualization of the prostate and boundaries in a phantom study.

  12. Ultrasound-Guided Selective Versus Conventional Block of the Medial Brachial Cutaneous and the Intercostobrachial Nerves: A Randomized Clinical Trial.

    PubMed

    Magazzeni, Philippe; Jochum, Denis; Iohom, Gabriella; Mekler, Gérard; Albuisson, Eliane; Bouaziz, Hervé

    2018-06-13

    For superficial surgery of anteromedial and posteromedial surfaces of the upper arm, the medial brachial cutaneous nerve (MBCN) and the intercostobrachial nerve (ICBN) must be selectively blocked, in addition to an axillary brachial plexus block. We compared efficacy of ultrasound-guided (USG) versus conventional block of the MBCN and the ICBN. Eighty-four patients, undergoing upper limb surgery, were randomized to receive either USG (n = 42) or conventional (n = 42) block of the MBCN and the ICBN with 1% mepivacaine. Sensory block was evaluated using light-touch on the upper and lower half of the anteromedial and posteromedial surfaces of the upper arm at 5, 10, 15, 20 minutes after nerve blocks. The primary outcome was the proportion of patients who had no sensation in all 4 regions innervated by the MBCN and the ICBN at 20 minutes. Secondary outcomes were onset time of complete anesthesia, volume of local anesthetic, tourniquet tolerance, and quality of ultrasound images. In the USG group, 37 patients (88%) had no sensation at 20 minutes in any of the 4 areas tested versus 8 patients (19%) in the conventional group (P < 0.001). When complete anesthesia was obtained, it occurred within 10 minutes in more than 90% of patients, in both groups. Mean total volumes of local anesthetic used for blocking the MBCN and the ICBN were similar in the 2 groups. Ultrasound images were of good quality in only 20 (47.6%) of 42 patients. Forty-one patients (97.6%) who received USG block were comfortable with the tourniquet versus 16 patients (38.1%) in the conventional group (P < 0.001). Ultrasound guidance improved the efficacy of the MBCN and ICBN blocks. This study was registered at ClinicalTrials.gov, identifier NCT02940847.

  13. Focused ultrasound in ophthalmology

    PubMed Central

    Silverman, Ronald H

    2016-01-01

    The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via ciliodestruction), tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. PMID:27757007

  14. Focused ultrasound in ophthalmology.

    PubMed

    Silverman, Ronald H

    2016-01-01

    The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via ciliodestruction), tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities.

  15. Simple ultrasound rules to distinguish between benign and malignant adnexal masses before surgery: prospective validation by IOTA group

    PubMed Central

    Ameye, Lieveke; Fischerova, Daniela; Epstein, Elisabeth; Melis, Gian Benedetto; Guerriero, Stefano; Van Holsbeke, Caroline; Savelli, Luca; Fruscio, Robert; Lissoni, Andrea Alberto; Testa, Antonia Carla; Veldman, Joan; Vergote, Ignace; Van Huffel, Sabine; Bourne, Tom; Valentin, Lil

    2010-01-01

    Objectives To prospectively assess the diagnostic performance of simple ultrasound rules to predict benignity/malignancy in an adnexal mass and to test the performance of the risk of malignancy index, two logistic regression models, and subjective assessment of ultrasonic findings by an experienced ultrasound examiner in adnexal masses for which the simple rules yield an inconclusive result. Design Prospective temporal and external validation of simple ultrasound rules to distinguish benign from malignant adnexal masses. The rules comprised five ultrasonic features (including shape, size, solidity, and results of colour Doppler examination) to predict a malignant tumour (M features) and five to predict a benign tumour (B features). If one or more M features were present in the absence of a B feature, the mass was classified as malignant. If one or more B features were present in the absence of an M feature, it was classified as benign. If both M features and B features were present, or if none of the features was present, the simple rules were inconclusive. Setting 19 ultrasound centres in eight countries. Participants 1938 women with an adnexal mass examined with ultrasound by the principal investigator at each centre with a standardised research protocol. Reference standard Histological classification of the excised adnexal mass as benign or malignant. Main outcome measures Diagnostic sensitivity and specificity. Results Of the 1938 patients with an adnexal mass, 1396 (72%) had benign tumours, 373 (19.2%) had primary invasive tumours, 111 (5.7%) had borderline malignant tumours, and 58 (3%) had metastatic tumours in the ovary. The simple rules yielded a conclusive result in 1501 (77%) masses, for which they resulted in a sensitivity of 92% (95% confidence interval 89% to 94%) and a specificity of 96% (94% to 97%). The corresponding sensitivity and specificity of subjective assessment were 91% (88% to 94%) and 96% (94% to 97%). In the 357 masses for which the

  16. [The value of methods for morphofunctional analysis of cornea in cataract surgery].

    PubMed

    Borodina, N B; Kobzova, M V; Musaeva, G M

    2011-01-01

    The characteristics of morphofunctional status of cornea after extracapsular cataract extraction and phakoemulsification with IOL implantation (30 and 58 operations respectively) were analyzed in detail using up-to-date diagnostic techniques. The results of examination using developed algorithm including study of light transmission, refraction and protective function of cornea show advantage of microinvasive ultrasound technique of cataract surgery in terms of minimal impact on corneal structure, optical and biomechanical characteristics.

  17. Research interface on a programmable ultrasound scanner.

    PubMed

    Shamdasani, Vijay; Bae, Unmin; Sikdar, Siddhartha; Yoo, Yang Mo; Karadayi, Kerem; Managuli, Ravi; Kim, Yongmin

    2008-07-01

    Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. The developed research

  18. Unpowered wireless generation and sensing of ultrasound

    NASA Astrophysics Data System (ADS)

    Huang, Haiying

    2013-04-01

    This paper presents a wireless ultrasound pitch-catch system that demonstrates the wireless generation and sensing of ultrasounds based on the principle of frequency conversion. The wireless ultrasound pitch-catch system consists of a wireless interrogator and two wireless ultrasound transducers. The wireless interrogator generates an ultrasound-modulated signal and a carrier signal, both at the microwave frequency, and transmits these two signals to the wireless ultrasound actuator using a pair of antennas. Upon receiving these two signals, the wireless ultrasound actuator recovers the ultrasound excitation signal using a passive mixer and then supplies it to a piezoelectric wafer sensor for ultrasound generation in the structure. For wireless ultrasound sensing, the frequency conversion process is reversed. The ultrasound sensing signal is up-converted to a microwave signal by the wireless ultrasound sensor and is recovered at the wireless interrogator using a homodyne receiver. To differentiate the wireless actuator from the wireless sensor, each wireless transducer is equipped with a narrowband microwave filter so that it only responds to the carrier frequency that matches the filter's operation bandwidth. The principle of operation of the wireless pitch-catch system, the hardware implementation, and the associated data processing algorithm to recover the ultrasound signal from the wirelessly received signal are described. The wirelessly acquired ultrasound signal is compared with those acquired using wired connection in both time and frequency domain.

  19. HIFU Monitoring and Control with Dual-Mode Ultrasound Arrays

    NASA Astrophysics Data System (ADS)

    Casper, Andrew Jacob

    The biological effects of high-intensity focused ultrasound (HIFU) have been known and studied for decades. HIFU has been shown capable of treating a wide variety of diseases and disorders. However, despite its demonstrated potential, HIFU has been slow to gain clinical acceptance. This is due, in part, to the difficulty associated with robustly monitoring and controlling the delivery of the HIFU energy. The non-invasive nature of the surgery makes the assessment of treatment progression difficult, leading to long treatment times and a significant risk of under treatment. This thesis research develops new techniques and systems for robustly monitoring HIFU therapies for the safe and efficacious delivery of the intended treatment. Systems and algorithms were developed for the two most common modes of HIFU delivery systems: single-element and phased array applicators. Delivering HIFU with a single element transducer is a widely used technique in HIFU therapies. The simplicity of a single element offers many benefits in terms of cost and overall system complexity. Typical monitoring schemes rely on an external device (e.g. diagnostic ultrasound or MRI) to assess the progression of therapy. The research presented in this thesis explores using the same element to both deliver and monitor the HIFU therapy. The use of a dual-mode ultrasound transducer (DMUT) required the development of an FPGA based single-channel arbitrary waveform generator and high-speed data acquisition unit. Data collected from initial uncontrolled ablations led to the development of monitoring and control algorithms which were implemented directly on the FPGA. Close integration between the data acquisition and arbitrary waveform units allowed for fast, low latency control over the ablation process. Results are presented that demonstrate control of HIFU therapies over a broad range of intensities and in multiple in vitro tissues. The second area of investigation expands the DMUT research to an

  20. Intraoperative definition of bottom-of-sulcus dysplasia using intraoperative ultrasound and single depth electrode recording - A technical note.

    PubMed

    Miller, Dorothea; Carney, Patrick; Archer, John S; Fitt, Gregory J; Jackson, Graeme D; Bulluss, Kristian J

    2018-02-01

    Bottom of sulcus dysplasias (BOSDs) are localized focal cortical dysplasias (FCDs) centred on the bottom of a sulcus that can be highly epileptogenic, but difficult to delineate intraoperatively. We report on a patient with refractory epilepsy due to a BOSD, successfully resected with the aid of a multimodal surgical approach using neuronavigation based on MRI and PET, intraoperative ultrasound (iUS) and electrocorticography (ECoG) using depth electrodes. The lesion could be visualized on iUS showing an increase in echogenicity at the grey-white matter junction. IUS demonstrated the position of the depth electrode in relation to the lesion. Depth electrode recording showed almost continuous spiking. Thus, intraoperative imaging and electrophysiology helped confirm the exact location of the lesion. Post-resection ultrasound demonstrated the extent of the resection and depth electrode recording did not show any epileptiform activity. Thus, both techniques helped assess completeness of resection. The patient has been seizure free since surgery. Using a multimodal approach including iUS and ECoG is a helpful adjunct in surgery for BOSD and may improve seizure outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Is Bariatric Surgery a Prophylaxis for Pelvic Floor Disorders?

    PubMed

    Pomian, Andrzej; Majkusiak, Wojciech; Lisik, Wojciech; Tomasik, Paweł; Horosz, Edyta; Zwierzchowska, Aneta; Kociszewski, Jacek; Barcz, Ewa

    2018-06-01

    Obesity is one of the well-documented risk factors of pelvic floor disorders (PFDs). The PFDs include urinary and fecal incontinence (UI, FI) and pelvic organ prolapse (POP). Surgery-induced weight loss improves different kinds of incontinence as well as POP symptoms. However, there is a lack of evidence how bariatric surgery influences pelvic floor anatomy and function in women without previous PFDs and whether it may be concerned as PFD prophylaxis tool. The present analysis is a prospective, non-randomized case-control study from January 2014 to September 2017. Participants underwent pelvic floor ultrasound examination with bladder neck position estimation at rest, during levator ani tension, and at Valsalva maneuver before surgery and 12-18 months after. Pelvic organ prolapse quantification (POPQ) > 2 stage and PFD complaints were the exclusion criteria. Fifty-nine patients underwent bariatric surgery (57 sleeve gastrectomy and 2 gastric bypass). Mean BMI decreased from 43.8 ± 5.9 to 29 ± 4.6 kg/m 2 after surgery (p < 0.001). Statistically significant higher position of the bladder neck at rest, during tension, and at Valsalva maneuver (p < 0.05) was shown after surgery. We did not demonstrate differences in bladder neck mobility and bladder neck elevation at tension after weight loss. Bariatric surgery is associated with a betterment of bladder neck position at rest, tension, and Valsalva maneuver in women without PFDs. We postulate that bariatric surgery may be a tool for PFD prevention. It does not improve levator ani function and does not limit bladder neck mobility, which implicates that it has no influence on preexisting pelvic dysfunction.

  2. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrationsmore » with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant

  3. Development of a fresh cadaver model for instruction of ultrasound-guided breast biopsy during the surgery clerkship: pre-test and post-test results among third-year medical students.

    PubMed

    McCrary, Hilary C; Krate, Jonida; Savilo, Christine E; Tran, Melissa H; Ho, Hang T; Adamas-Rappaport, William J; Viscusi, Rebecca K

    2016-11-01

    The aim of our study was to determine if a fresh cadaver model is a viable method for teaching ultrasound (US)-guided breast biopsy of palpable breast lesions. Third-year medical students were assessed both preinstruction and postinstruction on their ability to perform US-guided needle aspiration or biopsy of artificially created masses using a 10-item checklist. Forty-one third-year medical students completed the cadaver laboratory as part of the surgery clerkship. Eight items on the checklist were found to be significantly different between pre-testing and post-testing. The mean preinstruction score was 2.4, whereas the mean postinstruction score was 7.10 (P < .001). Fresh cadaver models have been widely used in medical education. However, there are few fresh cadaver models that provide instruction on procedures done in the outpatient setting. Our model was found to be an effective method for the instruction of US-guided breast biopsy among medical students. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Determining Directions of Ultrasound in Solids

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R.; Roth, Don J.

    1987-01-01

    Ultrasound shadows cast by grooves. Improved method for determining direction of ultrasound in materials is shadow method using Scanning laser acoustic microscopy (SLAM). Direction of ultrasound calculated from dimensions of groove and portion of surface groove shields from ultrasound. Method has variety of applications in nontraditional quality-control applications.

  5. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  6. Pain reduction and improvement of function following ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid in hip osteoarthritis.

    PubMed

    Araújo, J P; Silva, L; Andrade, R; Paços, M; Moreira, H; Migueis, N; Pereira, R; Sarmento, A; Pereira, H; Loureiro, N; Espregueira-Mendes, J

    2016-01-01

    The scientific literature has shown positive results regarding intra-articular injections of hyaluronic acid in osteoarthritic joints. When injecting in the hip joint, the guidance of ultrasound can provide higher injection accuracy and repeatability. However, due to the methodological limitations in the current available literature, its recommendation in the current practice is still controversial. This study shows that ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid can improve pain, function and quality of life in patients with symptomatic and radiographic hip osteoarthritis. In addition, the administration of triamcinolone hexacetonide and hyaluronic acid to the hip joint in these patients can delay the need for interventional surgery.

  7. Ultrasonographic diagnosis and longitudinal follow-up of recurrences after conservative surgery for borderline ovarian tumors.

    PubMed

    Franchi, Dorella; Boveri, Sara; Radice, Davide; Portuesi, Rosalba; Zanagnolo, Vanna; Colombo, Nicoletta; Testa, Antonia Carla

    2016-12-01

    Borderline ovarian tumors are generally diagnosed in young women. Because of the young age of patients at first diagnosis and at recurrence, and given the good prognosis of borderline ovarian tumors, a conservative surgical approach in those women who wish to preserve their fertility is advised. In this scenario, transvaginal ultrasound examination plays a key role in the detection of borderline ovarian tumor recurrence, and in assessment of amount of normal functioning parenchyma remaining. To date, no data are available about the natural history of borderline ovarian tumor recurrence. The aim of the study was to determine growth rate of recurrent ovarian cysts by a scheduled follow-up by ultrasound examination, in women previously treated with fertility-sparing surgery due to borderline ovarian tumors. In this prospective observational study, we collected data from 34 patients previously treated with fertility-sparing surgery due to borderline ovarian tumors, who had a suspicious recurrent lesion. The patients underwent transvaginal ultrasonographic examination every 3 months, until the clinical setting recommended proceeding with surgery. According to cyst size at study entry, they were categorized into 3 groups: ≤10 mm, 10-20 mm, and >20 mm. Summary statistics for cyst size, growth rate, and the probability of remaining within the same dimension category at first ultrasound during the follow-up were also obtained. For each cyst the growth rate was calculated as the slope of the linear interpolation between 2 consecutive measurements. Follow-up timing (P < .001), cyst size (P < .001), and micropapillary pattern (P < .001) were factors significantly affecting the cyst growth both in univariate and multivariate analysis. According to size category at first ultrasound, growth rate ranges from a minimum of 0.06 mm/mo for cysts <10 mm up to 1.92 mm/mo for cysts >20 mm. The final histology of all recurrent lesions confirmed the same histotype of primary borderline

  8. Introduction of Lens-angle Reconstruction Surgery in Rabbit Eyes

    PubMed Central

    Kim, Min Hee; Hwang, Ho Sik; Park, Kyoung Jin; Hwang, Je Hyung

    2014-01-01

    Purpose In this study, we examined the stability of the lens-angle supporter (LAS) for accommodation restoration by comparing intraocular lens (IOL) location, after-cataract and ciliary body damage after cataract surgery in rabbits. Methods Eight rabbits were divided into experimental and control groups of four rabbits each. Phacoemulsification and irrigation and aspiration were performed in all rabbits. This was followed by an LAS and IOL insertion in the four experimental rabbits. In the four control rabbits, only an IOL insertion was performed. Six months after the surgery, the location of the IOL, the conditions of the lens capsule and ciliary body were evaluated using a slitl-amp examination and Miyake-Apple view. Results For the experimental group, the ultrasound biomicroscope results showed normal LAS and IOL positioning in all four cases. According to the slitlamp examination and Miyake-Apple view, the IOL was positioned at the center, with less after-cataract and damage to the ciliary body. For the control group, ultrasound biomicroscope results indicated a higher IOL position than normal, as well as a single case of IOL decentering. According to the slit-lamp examination and Miyake-Apple view, the IOL was decentered with more severe after-cataract and ciliary body damage. Conclusions The LAS has the potential to maintain a stable IOL position while producing less after-cataract when used in lens-angle reconstruction for correction of presbyopia. Moreover, LAS implantation incurs less damage to the ciliary body. PMID:25435752

  9. Abdominal ultrasound and medical education.

    PubMed

    García de Casasola Sánchez, G; Torres Macho, J; Casas Rojo, J M; Cubo Romano, P; Antón Santos, J M; Villena Garrido, V; Diez Lobato, R

    2014-04-01

    Ultrasound is a very versatile diagnostic modality that permits real-time visualization of multiple internal organs. It is of invaluable help for the physical examination of the patients. To assess if ultrasound can be incorporated into medical education and if the students can perform a basic abdominal ultrasound examination without the necessity of a long period of training. Twelve medical students were trained in basic abdominal ultrasound during a 15-h training program including a 5-h theoretical and practical course and supervised practice in 20 selected patients. Subsequently, we conducted an evaluation test that assessed the ability of students to obtain the ultrasound views and to detect various pathologies in five different patients. The students were able to correctly identify the abdominal views more than 90% of the times. This percentage was only lower (80%) in the right subcostal view to locate the gallbladder. The accuracy or global efficiency of the ultrasound for the diagnosis of relevant pathological findings of the patients was greater than 90% (91.1% gallstones, abdominal aortic aneurysm 100%; splenomegaly 98.3%, ascites 100%; dilated inferior vena cava 100%; acute urinary retention 100%). The ultrasound may be a feasible learning tool in medical education. Ultrasound can help students to improve the physical examination. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  10. [Basics of emergency ultrasound].

    PubMed

    Schellhaas, S; Breitkreutz, R

    2012-09-05

    Focused ultrasound is a key methodology of critical care medicine. By referencing few ultrasound differential diagnosis, it is possible to identifying in real-time the reason of the critical state of a patient. Therefore typical focused ultrasound protocols were developed. The well known Focused Assessment with Sonography for trauma (FAST) was incorporated into the Advanced Trauma Life Support (ATLS) for shock room. Focused echocardiographic evaluation in life support (FEEL) has been designed to be conformed with the universal Advanced Life Support (ALS) algorithm and to identify treatable conditions such as acute right ventricular pressure overload in pulmonary embolism, hypovolemia, or pericardial effusion/tamponade. Using lung ultrasound one can differentiate pulmonary edema, pleural effusion or pneumothorax.

  11. Descriptive Cadaveric Study Comparing the Accuracy of Ultrasound Versus Fluoroscopic Guidance for First Sacral Transforaminal Injections: A Comparison Study.

    PubMed

    Thompson, Bradley F; Pingree, Matthew J; Qu, Wenchun; Murthy, Naveen S; Lachman, Nirusha; Hurdle, Mark Friedrich

    2018-04-01

    Ultrasound is rarely used for guiding lumbosacral epidural steroid injections due to its technical limitations. For example, sonographic imaging lacks the ability to confirm epidural spread and identify vascular uptake. The perceived risk that these limitations pose to human subjects has precluded any large scale clinical trials to date. To compare the accuracy of ultrasound versus fluoroscopic guidance for first sacral transforaminal epidural injections. Cadaveric comparative study using dichotomous outcomes. A fluoroscopy suite and anatomic laboratory at an academic medical center. Four unembalmed adult human cadavers with no history of spinal surgery. Eight sites were injected twice by one interventionalist, using fluoroscopic and ultrasound guidance. In the fluoroscopy arm, contrast spread was assessed using computed tomography. In the ultrasound arm, latex spread was assessed using gross anatomic dissection. Any visible evidence of epidural spread constituted a positive result. Comparison of the success of obtaining epidural contrast flow was the primary outcome measure. Secondary outcome measures included average duration, rate of intravascular uptake, and quantity of intravascular uptake. All injections performed in both the ultrasound arm and the fluoroscopy arm had positive epidural spread. The average duration was 3.03 minutes with fluoroscopy and 4.76 minutes with ultrasound. The rate of intravascular uptake was 37.5% with fluoroscopy and 50% with ultrasound. Within the ultrasound arm, greater intravascular spread and duration variability were recorded. Although ultrasonography can provide reliable image guidance for cannulating the first sacral foramen in cadavers, it would have limited clinical utility due to its inability to visualize relevant neurovascular structures deep to the osseus roof and exclude intravascular uptake. IV. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  12. Ultrasound Contrast Agents

    NASA Astrophysics Data System (ADS)

    Cachard, Christian; Basset, Olivier

    While the use of contrast agents in other imaging modalities (X ray, MRI, PET, …) has been routinely accepted for many years, the development and commercialization of contrast agents designed specifically for ultrasound imaging has occurred only very recently. As in the other imaging modalities, the injection of contrast agents during an ultrasound examination is intended to facilitate the detection and diagnosis of specific pathologies. Contrast agents efficiency is based on the backscattering of ultrasound by microbubbles. These microparticules are intravenously injected in the blood flow. After an introduction and generalities on ultrasound contrast agents (UCA) the microbubble physics in an acoustic field will be developed. Second, physics characteristics of contrast agents will be compared (bubbles with or without shell, gas nature, size distribution). Influence of acoustic pressure on the behaviour of the microparticules (linear, non linear and destruction) will be discussed. Finally, a review of specific imaging adapted to contrast agent properties as harmonic imaging, pulse inversion imaging will be presented.

  13. Eye and orbit ultrasound

    MedlinePlus

    Echography - eye orbit; Ultrasound - eye orbit; Ocular ultrasonography; Orbital ultrasonography ... eye is numbed with medicine (anesthetic drops). The ultrasound wand (transducer) is placed against the front surface ...

  14. Improved heating efficiency with High-Intensity Focused Ultrasound using a new ultrasound source excitation.

    PubMed

    Bigelow, Timothy A

    2009-01-01

    High-Intensity Focused Ultrasound (HIFU) is quickly becoming one of the best methods to thermally ablate tissue noninvasively. Unlike RF or Laser ablation, the tissue can be destroyed without inserting any probes into the body minimizing the risk of secondary complications such as infections. In this study, the heating efficiency of HIFU sources is improved by altering the excitation of the ultrasound source to take advantage of nonlinear propagation. For ultrasound, the phase velocity of the ultrasound wave depends on the amplitude of the wave resulting in the generation of higher harmonics. These higher harmonics are more efficiently converted into heat in the body due to the frequency dependence of the ultrasound absorption in tissue. In our study, the generation of the higher harmonics by nonlinear propagation is enhanced by transmitting an ultrasound wave with both the fundamental and a higher harmonic component included. Computer simulations demonstrated up to a 300% increase in temperature increase compared to transmitting at only the fundamental for the same acoustic power transmitted by the source.

  15. Action of therapeutic laser and ultrasound in peripheral nerve regeneration

    PubMed Central

    Oliveira, Fabrício Borges; Pereira, Valéria Martins Dias; da Trindade, Ana Paula Nassif Tondato; Shimano, Antônio Carlos; Gabriel, Ronaldo Eugênio Calçada Dias; Borges, Ana Paula Oliveira

    2012-01-01

    Objective To assess the efficacy of early therapeutic laser and ultrasound in the regeneration process of an injury in rats. Methods We used 24 rats. Eighteen underwent surgery for sciatic nerve compression by a hemostat above the popliteal fossa. The animals were divided into three groups of six animals each. Normal control group. GI: Injured control without therapeutic intervention. GII: laser ArGaAl therapeutic intervention. GIII: therapeutic intervention of Pulsed Ultrasound. We begin therapeutic interventions 24 hours after injury, with daily applications for a period of fourteen consecutive days. Results In assessing the girth of the muscles of the right they, the following average decrease (in mm) for each GI: 0.45, GII: 0.42, GIII: 0.40 In relation to travel time, both GII and GIII presented significant difference when compared to GI. In the final evaluation of the IFC, GII excelled in the GIII. As for the healing observed, a major great improvement was observed in GII and GIII. Conclusion The results showed that nerve recovery was higher with the laser application. Level of evidence II, Therapeutic Studies - Investigation of the results of treatment. PMID:24453589

  16. Stereoscopic augmented reality for laparoscopic surgery.

    PubMed

    Kang, Xin; Azizian, Mahdi; Wilson, Emmanuel; Wu, Kyle; Martin, Aaron D; Kane, Timothy D; Peters, Craig A; Cleary, Kevin; Shekhar, Raj

    2014-07-01

    Conventional laparoscopes provide a flat representation of the three-dimensional (3D) operating field and are incapable of visualizing internal structures located beneath visible organ surfaces. Computed tomography (CT) and magnetic resonance (MR) images are difficult to fuse in real time with laparoscopic views due to the deformable nature of soft-tissue organs. Utilizing emerging camera technology, we have developed a real-time stereoscopic augmented-reality (AR) system for laparoscopic surgery by merging live laparoscopic ultrasound (LUS) with stereoscopic video. The system creates two new visual cues: (1) perception of true depth with improved understanding of 3D spatial relationships among anatomical structures, and (2) visualization of critical internal structures along with a more comprehensive visualization of the operating field. The stereoscopic AR system has been designed for near-term clinical translation with seamless integration into the existing surgical workflow. It is composed of a stereoscopic vision system, a LUS system, and an optical tracker. Specialized software processes streams of imaging data from the tracked devices and registers those in real time. The resulting two ultrasound-augmented video streams (one for the left and one for the right eye) give a live stereoscopic AR view of the operating field. The team conducted a series of stereoscopic AR interrogations of the liver, gallbladder, biliary tree, and kidneys in two swine. The preclinical studies demonstrated the feasibility of the stereoscopic AR system during in vivo procedures. Major internal structures could be easily identified. The system exhibited unobservable latency with acceptable image-to-video registration accuracy. We presented the first in vivo use of a complete system with stereoscopic AR visualization capability. This new capability introduces new visual cues and enhances visualization of the surgical anatomy. The system shows promise to improve the precision and

  17. Breast ultrasound tomography with two parallel transducer arrays

    NASA Astrophysics Data System (ADS)

    Huang, Lianjie; Shin, Junseob; Chen, Ting; Lin, Youzuo; Gao, Kai; Intrator, Miranda; Hanson, Kenneth

    2016-03-01

    Breast ultrasound tomography is an emerging imaging modality to reconstruct the sound speed, density, and ultrasound attenuation of the breast in addition to ultrasound reflection/beamforming images for breast cancer detection and characterization. We recently designed and manufactured a new synthetic-aperture breast ultrasound tomography prototype with two parallel transducer arrays consisting of a total of 768 transducer elements. The transducer arrays are translated vertically to scan the breast in a warm water tank from the chest wall/axillary region to the nipple region to acquire ultrasound transmission and reflection data for whole-breast ultrasound tomography imaging. The distance of these two ultrasound transducer arrays is adjustable for scanning breasts with different sizes. We use our breast ultrasound tomography prototype to acquire phantom and in vivo patient ultrasound data to study its feasibility for breast imaging. We apply our recently developed ultrasound imaging and tomography algorithms to ultrasound data acquired using our breast ultrasound tomography system. Our in vivo patient imaging results demonstrate that our breast ultrasound tomography can detect breast lesions shown on clinical ultrasound and mammographic images.

  18. Prostate ultrasound: back in business!

    PubMed

    Crisan, Nicolae; Andras, Iulia; Radu, Corina; Andras, David; Coman, Radu-Tudor; Tucan, Paul; Pisla, Doina; Crisan, Dana; Coman, Ioan

    2017-11-29

    The use of grey scale prostate ultrasound decreased after the implementation of magnetic resonance imaging (MRI) for the diagnosis and evaluation of prostate cancer. The new developments, such as multiparametric ultrasound and MRI-ultrasound fusion technology, renewed the interest for this imaging method in the assessment of prostate cancer. The purpose of this paper was to review the current role of prostate ultrasound in the setting of these new applications. A thorough reevaluation of the selection criteria of the patients is required to assess which patients would benefit from multiparametric ultrasound, who wouldbenefit from multiparametric MRI or the combination of both to assist prostate biopsy in order to ensure the balance between overdiagnosis and underdiagnosis of prostate cancer.

  19. Reduction of the Areolar Diameter After Ultrasound-Assisted Liposuction for Gynecomastia.

    PubMed

    Keskin, Mustafa; Sutcu, Mustafa; Hanci, Mustafa; Cigsar, Bulent

    2017-08-01

    One of the clinical aspects characterizing gynecomastia is the enlargement of the nipple-areolar complex (NAC) due to hypertrophic breast glands, and the excessive fatty tissue underneath. The purpose of this study was to quantify the reduction of the areolar diameter after ultrasound-assisted liposuction (UAL) of the male breast. The horizontal diameters of the NACs of 30 men who underwent UAL were measured before surgery, 1 month after surgery and 6 months after surgery in a standard fashion. Those patients with surgical gland removals of any kind were not included in this study. The mean age of the patients was 27.9 years, and all of the patients had bilateral grade I, II, or III gynecomastia. The mean diameter of the NACs before surgery was 35.36 mm (range, 26-55 mm), and after surgery, the mean diameter of the NACs was initially reduced to 28.8 mm (range, 23-44 mm) and later to 28.57 mm (range, 23-42 mm). The mean volume of breast tissue aspirated was 382 mL per breast, and the percentage of reduction was 17.3%. The reduction of areola diameter was statistically significant after first month. A significant positive correlation was identified between the liposuction volume and areolar diameter reduction. In cases of gynecomastia, the removal of the glandular and fatty tissue underneath the areola releases the expanding forces and pressure that enlarge it. In many cases of gynecomastia, UAL alone is effective in reducing the size of the NAC and allows the surgeon to avoid placing scars on the breast.

  20. Virtual Guidance Ultrasound: A Tool to Obtain Diagnostic Ultrasound for Remote Environments

    NASA Technical Reports Server (NTRS)

    Caine,Timothy L.; Martin David S.; Matz, Timothy; Lee, Stuart M. C.; Stenger, Michael B.; Platts, Steven H.

    2012-01-01

    Astronauts currently acquire ultrasound images on the International Space Station with the assistance of real-time remote guidance from an ultrasound expert in Mission Control. Remote guidance will not be feasible when significant communication delays exist during exploration missions beyond low-Earth orbit. For example, there may be as much as a 20- minute delay in communications between the Earth and Mars. Virtual-guidance, a pre-recorded audio-visual tutorial viewed in real-time, is a viable modality for minimally trained scanners to obtain diagnostically-adequate images of clinically relevant anatomical structures in an autonomous manner. METHODS: Inexperienced ultrasound operators were recruited to perform carotid artery (n = 10) and ophthalmic (n = 9) ultrasound examinations using virtual guidance as their only instructional tool. In the carotid group, each each untrained operator acquired two-dimensional, pulsed, and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. RESULTS: Eight of the 10 carotid studies were judged to be diagnostically adequate. With one exception the quality of all the ophthalmic images were adequate to excellent. CONCLUSION: Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by untrained operators with instruction only from an audio/video tutorial viewed in real time while scanning. This form of quick-response-guidance, can be developed for other ultrasound examinations, represents an opportunity to acquire important medical and scientific information for NASA flight surgeons and researchers when trained medical personnel are not present. Further, virtual guidance will allow untrained personnel to autonomously obtain important medical information in remote locations on Earth where communication is

  1. Wound and surface temperatures in vivo in torsional and longitudinal modalities of ultrasound in coaxial microincisional cataract surgery

    PubMed Central

    Nair, Swapna; Nair, Ramachandran Unnikrishnan

    2017-01-01

    Background To study phacoemulsification probe shaft/wound and corneal surface/tip temperatures in vivo during longitudinal, torsional and combined phacoemulsification modes and their relationship to machine parameters. Design This was a prospective study at Chaithanya Eye Hospital and Research Institute, Trivandrum, India (tertiary). Participants Twenty-two eyes of 22 patients were randomized into six groups depending on the grade of nuclear sclerosis (NS) and the type of ultrasound used: Group 1, torsional in NS2; Group 2, torsional in NS3; Group 3, torsional with intermittent longitudinal in NS2; Group 4, torsional with intermittent longitudinal in NS3; Group 5, longitudinal in NS2; Group 6, longitudinal in NS3. Methods Patients underwent phacoemulsification by torsional, longitudinal or combined modalities. A thermal camera was used to measure phaco probe temperatures. Main outcome measures The mean probe shaft and tip temperatures were documented for different ultrasound modalities. Results The mean shaft and tip temperatures were: Group 1, 29.22°C±0.71°C and 28.4°C±0.88°C; Group 2, 32.12°C±0.62°C and 31.88°C±0.84°C; Group 3, 30.25°C±0.71°C and 29.35°C±0.62°C; Group 4, 31.95°C±0.65°C and 32.01°C±1.31°C; Group 5, 23°C and 27.6°C and Group 6, 23°C and 29.68°C, respectively. In all groups using longitudinal ultrasound, the phaco tip surface temperatures were higher than the shaft temperatures, except in Group 3. Shaft temperatures were higher than tip temperatures in cases using torsional phaco, except in Group 4. The mean temperature difference between groups was significant only for shaft temperatures (P=0.001). On thermal imaging, for torsional phaco, the rise in temperature of the probe from shaft to tip was dependent on the amplitude of ultrasound applied (P=0.009). Conclusion The shaft temperatures were higher than over the phaco tip during torsional phacoemulsification. PMID:28184151

  2. Cost-effectiveness of magnetic resonance imaging versus ultrasound for the detection of symptomatic full-thickness supraspinatus tendon tears.

    PubMed

    Gyftopoulos, Soterios; Guja, Kip E; Subhas, Naveen; Virk, Mandeep S; Gold, Heather T

    2017-12-01

    The purpose of this study was to determine the value of magnetic resonance imaging (MRI) and ultrasound-based imaging strategies in the evaluation of a hypothetical population with a symptomatic full-thickness supraspinatus tendon (FTST) tear using formal cost-effectiveness analysis. A decision analytic model from the health care system perspective for 60-year-old patients with symptoms secondary to a suspected FTST tear was used to evaluate the incremental cost-effectiveness of 3 imaging strategies during a 2-year time horizon: MRI, ultrasound, and ultrasound followed by MRI. Comprehensive literature search and expert opinion provided data on cost, probability, and quality of life estimates. The primary effectiveness outcome was quality-adjusted life-years (QALYs) through 2 years, with a willingness-to-pay threshold set to $100,000/QALY gained (2016 U.S. dollars). Costs and health benefits were discounted at 3%. Ultrasound was the least costly strategy ($1385). MRI was the most effective (1.332 QALYs). Ultrasound was the most cost-effective strategy but was not dominant. The incremental cost-effectiveness ratio for MRI was $22,756/QALY gained, below the willingness-to-pay threshold. Two-way sensitivity analysis demonstrated that MRI was favored over the other imaging strategies over a wide range of reasonable costs. In probabilistic sensitivity analysis, MRI was the preferred imaging strategy in 78% of the simulations. MRI and ultrasound represent cost-effective imaging options for evaluation of the patient thought to have a symptomatic FTST tear. The results indicate that MRI is the preferred strategy based on cost-effectiveness criteria, although the decision between MRI and ultrasound for an imaging center is likely to be dependent on additional factors, such as available resources and workflow. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    PubMed

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  4. Basic Study for Ultrasound-Based Navigation for Pedicle Screw Insertion Using Transmission and Backscattered Methods

    PubMed Central

    Chen, Ziqiang; Wu, Bing; Zhai, Xiao; Bai, Yushu; Zhu, Xiaodong; Luo, Beier; Chen, Xiao; Li, Chao; Yang, Mingyuan; Xu, Kailiang; Liu, Chengcheng; Wang, Chuanfeng; Zhao, Yingchuan; Wei, Xianzhao; Chen, Kai; Yang, Wu; Ta, Dean; Li, Ming

    2015-01-01

    The purpose of this study was to understand the acoustic properties of human vertebral cancellous bone and to study the feasibility of ultrasound-based navigation for posterior pedicle screw fixation in spinal fusion surgery. Fourteen human vertebral specimens were disarticulated from seven un-embalmed cadavers (four males, three females, 73.14 ± 9.87 years, two specimens from each cadaver). Seven specimens were used to measure the transmission, including tests of attenuation and phase velocity, while the other seven specimens were used for backscattered measurements to inspect the depth of penetration and A-Mode signals. Five pairs of unfocused broadband ultrasonic transducers were used for the detection, with center frequencies of 0.5 MHz, 1 MHz, 1.5 MHz, 2.25 MHz, and 3.5 MHz. As a result, good and stable results were documented. With increased frequency, the attenuation increased (P<0.05), stability of the speed of sound improved (P<0.05), and penetration distance decreased (P>0.05). At about 0.6 cm away from the cortical bone, warning signals were easily observed from the backscattered measurements. In conclusion, the ultrasonic system proved to be an effective, moveable, and real-time imaging navigation system. However, how ultrasonic navigation will benefit pedicle screw insertion in spinal surgery needs to be determined. Therefore, ultrasound-guided pedicle screw implantation is theoretically effective and promising. PMID:25861053

  5. Clinical applications of very high frequency ultrasound in ophthalmology

    NASA Astrophysics Data System (ADS)

    Silverman, Ronald H.; Coleman, D. Jackson; Reinstein, Dan Z.; Lizzi, Frederic L.

    2004-05-01

    The eye is ideally suited for diagnostic imaging with very high frequency (>35 MHz) ultrasound (VHFU) because of its peripheral location and cystic structure. VHFU allows high resolution visualization of pathologies affecting the anterior segment of the eye, including tumors, cysts, foreign bodies, and corneal pathologies. We developed a series of prototype instruments suitable for ophthalmic studies using both polymer and lithium niobate transducers, with digitization of radiofrequency echo data at up to 500 MHz. While initially using linear scan geometries, we subsequently developed an arc-shaped scan matched to the curvature of the 0.5-mm-thick cornea to circumvent the effect of specular deflection of the ultrasound beam produced by the corneas curved surface. This technique allowed us to obtain data across the entire cornea and determination of the thickness of each corneal layer, including the epithelium (approximately 50 microns in thickness) and the surgically induced interface produced in LASIK, the most common form of refractive surgery. By scanning in a series of meridians, and applying optimized signal processing strategies (deconvolution, analytic signal envelope determination), corneal pachymetric maps representing the local thickness of each layer can be generated and aid in diagnosis of surgically induced defects or refractive abnormalities.

  6. Recent advances in ultrasound-triggered therapy.

    PubMed

    Yang, Chaopin; Li, Yue; Du, Meng; Chen, Zhiyi

    2018-04-27

    As a non-invasive and real-time diagnostic technique, ultrasound has provided a novel strategy for targeted treatment. With the rapid development of ultrasonic technique and ultrasound contrast agents (UCAs), spatiotemporally controllable application of ultrasound with or without UCAs makes it possible for site-specific delivery of therapeutic agents and targeted modulation with minimal side effects, which indicated a promising therapy in clinical use. This review will describe the main mechanism of targeted therapy induced by ultrasound briefly, then focus on the current application of ultrasound mediated targeted therapy in various fields including tumour, cardiovascular disease, central nervous system, skeletal muscle system diseases and stem cells therapy. In addition, ongoing challenges of ultrasound-mediated targeted therapy for further research and its clinical use are reviewed.

  7. Driving delivery vehicles with ultrasound

    PubMed Central

    Ferrara, Katherine W.

    2009-01-01

    Therapeutic applications of ultrasound have been considered for over 40 years, with the mild hyperthermia and associated increases in perfusion produced by ultrasound harnessed in many of the earliest treatments. More recently, new mechanisms for ultrasound-based or ultrasound-enhanced therapies have been described, and there is now great momentum and enthusiasm for the clinical translation of these techniques. This dedicated issue of Advanced Drug Delivery Reviews, entitled “Ultrasound for Drug and Gene Delivery,” addresses the mechanisms by which ultrasound can enhance local drug and gene delivery and the applications that have been demonstrated at this time. In this commentary, the identified mechanisms, delivery vehicles, applications and current bottlenecks for translation of these techniques are summarized. PMID:18479775

  8. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients

    PubMed Central

    Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-01-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173

  9. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    PubMed

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  10. Ethical analysis of non-medical fetal ultrasound.

    PubMed

    Leung, John Lai Yin; Pang, Samantha Mei Che

    2009-09-01

    Obstetric ultrasound is the well-recognized prenatal test used to visualize and determine the condition of a pregnant woman and her fetus. Apart from the clinical application, some businesses have started promoting the use of fetal ultrasound machines for nonmedical reasons. Non-medical fetal ultrasound (also known as 'keepsake' ultrasound) is defined as using ultrasound to view, take a picture, or determine the sex of a fetus without a medical indication. Notwithstanding the guidelines and warnings regarding ultrasound safety issued by governments and professional bodies, the absence of scientifically proven physical harm to fetuses from this procedure seems to provide these businesses with grounds for rapid expansion. However, this argument is too simplistic because current epidemiological evidence is not synchronous with advancing ultrasound technology. As non-medical fetal ultrasound has aroused very significant public attention, a thorough ethical analysis of this topic is essential. Using a multifaceted approach, we analyse the ethical perspective of non-medical fetal ultrasound in terms of the expectant mother, the fetus and health professionals. After applying four major theories of ethics and principles (the precautionary principle; theories of consequentialism and impartiality; duty-based theory; and rights-based theories), we conclude that obstetric ultrasound practice is ethically justifiable only if the indication for its use is based on medical evidence. Non-medical fetal ultrasound can be considered ethically unjustifiable. Nevertheless, the ethical analysis of this issue is time dependent owing to rapid advancements in ultrasound technology and the safety issue. The role of health professionals in ensuring that obstetric ultrasound is an ethically justifiable practice is also discussed.

  11. Non-Invasive In Vivo Ultrasound Temperature Estimation

    NASA Astrophysics Data System (ADS)

    Bayat, Mahdi

    New emerging technologies in thermal therapy require precise monitoring and control of the delivered thermal dose in a variety of situations. The therapeutic temperature changes in target tissues range from few degrees for releasing chemotherapy drugs encapsulated in the thermosensitive liposomes to boiling temperatures in complete ablation of tumors via cell necrosis. High intensity focused ultrasound (HIFU) has emerged as a promising modality for noninvasive surgery due to its ability to create precise mechanical and thermal effects at the target without affecting surrounding tissues. An essential element in all these procedures, however, is accurate estimation of the target tissue temperature during the procedure to ensure its safety and efficacy. The advent of diagnostic imaging tools for guidance of thermal therapy was a key factor in the clinical acceptance of these minimally invasive or noninvasive methods. More recently, ultrasound and magnetic resonance (MR) thermography techniques have been proposed for guidance, monitoring, and control of noninvasive thermal therapies. MR thermography has shown acceptable sensitivity and accuracy in imaging temperature change and it is currently FDA-approved on clinical HIFU units. However, it suffers from limitations like cost of integration with ultrasound therapy system and slow rate of imaging for real time guidance. Ultrasound, on the other hand, has the advantage of real time imaging and ease of integration with the therapy system. An infinitesimal model for imaging temperature change using pulse-echo ultrasound has been demonstrated, including in vivo small-animal imaging. However, this model suffers from limitations that prevent demonstration in more clinically-relevant settings. One limitation stems from the infinitesimal nature of the model, which results in spatial inconsistencies of the estimated temperature field. Another limitation is the sensitivity to tissue motion and deformation during in vivo, which

  12. Development of a control algorithm for the ultrasound scanning robot (NCCUSR) using ultrasound image and force feedback.

    PubMed

    Kim, Yeoun Jae; Seo, Jong Hyun; Kim, Hong Rae; Kim, Kwang Gi

    2017-06-01

    Clinicians who frequently perform ultrasound scanning procedures often suffer from musculoskeletal disorders, arthritis, and myalgias. To minimize their occurrence and to assist clinicians, ultrasound scanning robots have been developed worldwide. Although, to date, there is still no commercially available ultrasound scanning robot, many control methods have been suggested and researched. These control algorithms are either image based or force based. If the ultrasound scanning robot control algorithm was a combination of the two algorithms, it could benefit from the advantage of each one. However, there are no existing control methods for ultrasound scanning robots that combine force control and image analysis. Therefore, in this work, a control algorithm is developed for an ultrasound scanning robot using force feedback and ultrasound image analysis. A manipulator-type ultrasound scanning robot named 'NCCUSR' is developed and a control algorithm for this robot is suggested and verified. First, conventional hybrid position-force control is implemented for the robot and the hybrid position-force control algorithm is combined with ultrasound image analysis to fully control the robot. The control method is verified using a thyroid phantom. It was found that the proposed algorithm can be applied to control the ultrasound scanning robot and experimental outcomes suggest that the images acquired using the proposed control method can yield a rating score that is equivalent to images acquired directly by the clinicians. The proposed control method can be applied to control the ultrasound scanning robot. However, more work must be completed to verify the proposed control method in order to become clinically feasible. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Preoperative Ultrasound Prediction of Essential Landmarks for Successful Fetoscopic Laser Treatment of Twin-Twin Transfusion Syndrome.

    PubMed

    Miller, Jena L; Block-Abraham, Dana M; Blakemore, Karin J; Baschat, Ahmet A

    2018-06-06

    The insertion site of the fetoscope for laser occlusion (FLOC) treatment of twin-twin transfusion syndrome (TTTS) determines the likelihood of treatment success. We assessed a standardized preoperative ultrasound approach for its ability to identify critical landmarks for successful FLOC. Three surgeons independently performed preoperative ultrasound and deduced the likely orientation of the intertwin membrane (ITM) and vascular equator (VE) based on the sites of the cord insertion, the lie of the donor, and the size discordance between twins. At FLOC, these landmarks were visually verified and compared to preoperative assessments. Fifty consecutive FLOC surgeries had 127 preoperative assessments. Basic ITM and VE orientation were accurately predicted in 115 (90.6%), 109 (85.8%), and 105 (82.7%) assessments. Predictions were anatomically correct in 96 (75.6%), 70 (55.1%), and 58 (45.7%) assessments with no differences in accuracy between operators of different training level. The ITM/VE relationship was most poorly predicted in stage-3 TTTS (χ2, p = 0.016). In TTTS, preoperative ultrasound identification of placental cord insertion sites, lie of the donor twin, and size discordance enables preoperative prediction of key landmarks for successful FLOC. © 2018 S. Karger AG, Basel.

  14. Dual-frequency ultrasound focal therapy for MRI-guided transurethral treatment of the prostate: Study in gel phantom

    NASA Astrophysics Data System (ADS)

    N'Djin, W. Apoutou; Mougenot, Charles; Kobelevskiy, Ilya; Ramsay, Elizabeth; Bronskill, Michael; Chopra, Rajiv

    2012-11-01

    Ultrasound thermal therapy of localized prostate cancer offers a minimally-invasive non-ionizing alternative [1-3] to surgery and radiotherapy. MRI-controlled transurethral ultrasound prostate therapy [4-6] has previously been investigated in a pilot human feasibility study [7], by treating a small sub-volume of prostate tissue. In this study, the feasibility of transurethral dual-frequency ultrasound focal therapy has been investigated in gel phantom. A database of pelvic anatomical models of human prostate cancer patients have been created using MR clinical images. The largest prostate boundary (47 cm3) was used to fabricate an anatomical gel phantom which included various MR characteristics to mimic prostate tissues, 4 localized tumors and surrounding prostate tissues. A 9-element transurethral ultrasound applicator working in dual-frequency mode (f = 4.6/14.5 MHz) was evaluated to heat: (i) the entire prostate volume (Full prostate treatment strategy), (ii) a prostate region restricted to tumors (Focal therapy). Acoustic power of each element and rotation rate of the device were adjusted in realtime based on MR-thermometry feedback control (nine thermal slices updated every 6.2s). Experiments have been performed using dual-frequency ultrasound exposures (surface Pmax: 20W.cm-2). (i) For full prostate heating, 7 elements of the device were used to cover the entire prostate length. The heating process was completed within 35 min. Ultrasound exposures at the fundamental frequency allowed full heating of the largest prostate radii (>18 mm), while exposures at the 3rd harmonic ensured homogeneous treatment of the smallest radii. Undertreated and overtreated regions represented respectively 2% and 17% of the prostate volume. (ii) For focal therapy, the target region was optimized to maintain safe regions in the prostate and to cover all tumor-mimics. Only 5 ultrasound elements were used to treat successfully all tumor-mimics within 26 min. Undertreated and

  15. Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.

    PubMed

    Manaf, Noraida Abd; Aziz, Maizatul Nadwa Che; Ridzuan, Dzulfadhli Saffuan; Mohamad Salim, Maheza Irna; Wahab, Asnida Abd; Lai, Khin Wee; Hum, Yan Chai

    2016-06-01

    Recently, there is an increasing interest in the use of local hyperthermia treatment for a variety of clinical applications. The desired therapeutic outcome in local hyperthermia treatment is achieved by raising the local temperature to surpass the tissue coagulation threshold, resulting in tissue necrosis. In oncology, local hyperthermia is used as an effective way to destroy cancerous tissues and is said to have the potential to replace conventional treatment regime like surgery, chemotherapy or radiotherapy. However, the inability to closely monitor temperature elevations from hyperthermia treatment in real time with high accuracy continues to limit its clinical applicability. Local hyperthermia treatment requires real-time monitoring system to observe the progression of the destroyed tissue during and after the treatment. Ultrasound is one of the modalities that have great potential for local hyperthermia monitoring, as it is non-ionizing, convenient and has relatively simple signal processing requirement compared to magnetic resonance imaging and computed tomography. In a two-dimensional ultrasound imaging system, changes in tissue microstructure during local hyperthermia treatment are observed in terms of pixel value analysis extracted from the ultrasound image itself. Although 2D ultrasound has shown to be the most widely used system for monitoring hyperthermia in ultrasound imaging family, 1D ultrasound on the other hand could offer a real-time monitoring and the method enables quantitative measurement to be conducted faster and with simpler measurement instrument. Therefore, this paper proposes a new local hyperthermia monitoring method that is based on one-dimensional ultrasound. Specifically, the study investigates the effect of ultrasound attenuation in normal and pathological breast tissue when the temperature in tissue is varied between 37 and 65 °C during local hyperthermia treatment. Besides that, the total protein content measurement was also

  16. Focused ultrasound thermal therapy system with ultrasound image guidance and temperature measurement feedback.

    PubMed

    Lin, Kao-Han; Young, Sun-Yi; Hsu, Ming-Chuan; Chan, Hsu; Chen, Yung-Yaw; Lin, Win-Li

    2008-01-01

    In this study, we developed a focused ultrasound (FUS) thermal therapy system with ultrasound image guidance and thermocouple temperature measurement feedback. Hydraulic position devices and computer-controlled servo motors were used to move the FUS transducer to the desired location with the measurement of actual movement by linear scale. The entire system integrated automatic position devices, FUS transducer, power amplifier, ultrasound image system, and thermocouple temperature measurement into a graphical user interface. For the treatment procedure, a thermocouple was implanted into a targeted treatment region in a tissue-mimicking phantom under ultrasound image guidance, and then the acoustic interference pattern formed by image ultrasound beam and low-power FUS beam was employed as image guidance to move the FUS transducer to have its focal zone coincident with the thermocouple tip. The thermocouple temperature rise was used to determine the sonication duration for a suitable thermal lesion as a high power was turned on and ultrasound image was used to capture the thermal lesion formation. For a multiple lesion formation, the FUS transducer was moved under the acoustic interference guidance to a new location and then it sonicated with the same power level and duration. This system was evaluated and the results showed that it could perform two-dimensional motion control to do a two-dimensional thermal therapy with a small localization error 0.5 mm. Through the user interface, the FUS transducer could be moved to heat the target region with the guidance of ultrasound image and acoustic interference pattern. The preliminary phantom experimental results demonstrated that the system could achieve the desired treatment plan satisfactorily.

  17. Ovarian preservation with subcutaneous transposition in the setting of cytoreductive surgery

    PubMed Central

    Tan, Winson Jianhong; Jung, JingJin; Chia, Claramae Shulyn; Teo, Melissa Ching Ching; Toh, Han Chong; Soo, Khee Chee

    2013-01-01

    INTRODUCTION In recent years, cytoreductive surgery (CRS) with hyperthermic intraperitoneal chemotherapy (HIPEC) has gained increasing acceptance as a treatment modality for peritoneal carcinomatosis. In female patients, this procedure involves a total hysterectomy and bilateral saphingo-oophorectomy to remove the pelvic peritoneum. We present a case of an unfortunate female adolescent with peritoneal carcinomatosis who underwent cytoreductive surgery and HIPEC. In view of the compelling circumstance, an innovative surgical technique was used to attempt ovarian preservation. PRESENTATION OF CASE A 14 year old girl with carcinoma of the sigmoid colon and peritoneal metastases was offered cytoreductive surgery and hyperthermic intra-peritoneal chemotherapy. In view of her age, ovarian preservation with subcutaneous transposition was performed during cytoreductive surgery. She is currently well 6 months post surgery and has resumed normal menstruation. We review the literature regarding ovarian preservation with subcutaneous transposition and discuss its benefit in pre-menopausal women undergoing peritonectomy and cytoreductive surgery for peritoneal carcinomatosis. DISCUSSION Subcutaneous transposition of the ovary in pre-menopasual patients requiring cytoreductive surgery spares them the sequelae of surgical castration. The subcutaneous location of the transposed ovary conveys advantages such as the ease of ultrasound surveillance and removal in event of disease recurrence. It also retains the possibility of future conception as the transposed ovary can easily be accessed for ovum extraction with assisted reproductive techniques. CONCLUSION Ovarian preservation with subcutaneous transposition is a technique worth considering in the treatment of pre-menopausal women who require cytoreductive surgery for peritoneal carcinomatosis. PMID:23396395

  18. A review of randomised controlled trials comparing ultrasound-guided foam sclerotherapy with endothermal ablation for the treatment of great saphenous varicose veins.

    PubMed

    Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W

    2016-05-01

    The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author

  19. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    PubMed

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  20. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.