Sample records for ultrasound-guided botox injections

  1. Ultrasound-guided intrasphincteric botulinum toxin injection relieves obstructive defecation due to Hirschsprung's disease and internal anal sphincter achalasia.

    PubMed

    Church, Joseph T; Gadepalli, Samir K; Talishinsky, Toghrul; Teitelbaum, Daniel H; Jarboe, Marcus D

    2017-01-01

    Chronic obstructive defecation can occur in patients with Hirschsprung Disease (HD) and internal anal sphincter (IAS) achalasia. Injection of Botulinum Toxin (BoTox) into the IAS can temporarily relieve obstructive defecation, but can be challenging when performed by tactile sense alone. We compared results of BoTox injections with and without ultrasound (US) guidance. We retrospectively reviewed BoTox injections into the IAS for obstructive defecation over 5years. Analyzed outcomes included short-term improvement, defined as resolution of enterocolitis, new ability to spontaneously defecate, and/or normalization of bowel movement frequency 2weeks post-operatively, as well as requirement of more definitive surgical therapy (myotomy/myomectomy, colectomy, colostomy, cecostomy/appendicostomy, and/or sacral nerve stimulator implantation). Outcomes were compared using t-test and Fisher's Exact test, with significance defined as p<0.05. Twelve patients who underwent BoTox injection were included, including 5 patients who underwent injections both with and without ultrasound. Ten underwent an ultrasound-guided injection (13 injection procedures), 5 of whom had HD. Seven underwent an injection without ultrasound guidance (17 injection procedures), 5 of whom had HD. Procedures performed with US resulted in greater short-term improvement (76% versus 65% without ultrasound) and less requirement of a definitive procedure for obstructive defecation (p<0.05). US-guided BoTox injection is safe and effective for obstructive defecation, and may decrease the need for a definitive operation. III. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Endoscopic botox injections in therapy of refractory gastroparesis

    PubMed Central

    Ukleja, Andrew; Tandon, Kanwarpreet; Shah, Kinchit; Alvarez, Alicia

    2015-01-01

    Gastroparesis (GP) is a common disease seen in gastroenterology practice particularly in western countries, and it may be underdiagnosed. The available drug therapies for this condition are quite disappointing. Botulinum toxin type A (BT) has been found to be effective therapy in various spastic disorders of smooth muscle of gastrointestinal tract. However, the benefits of BT injections in GP have been unclear. Several retrospective and open label studies have shown clinical advantages of intrapyloric Botulinum toxin type A injections, while two small randomized trials did not show positive results. Therefore, the available published studies yielded conflicting results leading to fading out of botox therapy for GP. We recognize possible clinical benefit of BT injections without any disadvantages of this treatment. We are calling for revisiting the endoscopy guided botox therapy in refractory GP. In this review we discuss important features of these studies pointing out differences in results among them. Differences in patient selection, doses and method of administration of botox toxin in the prior studies may be the cause of conflicting results. The mechanism of action, indications, efficacy and side-effects of BT are reviewed. Finally, we recognize limited evidence to recommend BT in GP and calling attention for future research in this field since no advances in drug management had been made in the last two decades. PMID:26191343

  3. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    PubMed

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  4. Therapeutic Plasma Exchange in a rare case myasthenic crisis after Botox injection.

    PubMed

    Chegini, Azita

    2017-11-01

    Botulinum toxin (Botox) injections are used as a cosmetic treatment to decrease wrinkles in face and chin. Being a neurotoxic agent it minimizes muscle activity, while side effects are usually rare. This article subsequently presents one case of these rare effects. A 30-year-old woman presenting with ptosis, diplopia, dysarthria, dysphagia and muscle weakness was admitted to our hospital. She had no history of disease. For cosmetic reasons, she had three Botox injections during the preceding months. On physical examination, muscle weakness 4/5 (cervical extensor, ocular and pharynx) was detected and a diagnosis of myasthenia gravis was made. Protective artificial ventilation was necessary. As a consequence, eight sessions of 2.5 L volume Therapeutic Plasma Exchange (TPE) were applied using normal saline/albumin as substitute. Due to TPE, her muscle force and clinical condition improved. Artificial ventilation could be stopped. Clinical symptoms of myasthenia gravis and systemic Botox effects are very similar. This should be taken into consideration during medical history taking. The injection of high doses of Botox (more than 200 units in every injection) or boostering within less than one month is dangerous. (Botox BCC2024). Systemic side effects can be treated using TPE to lower the circulating dose of Botox. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Use of prophylactic antibiotics for intra-vesicle Botox® injection.

    PubMed

    Khan, Mohammad Hassan; Baldo, Omer; Koenig, Philip; Shaikh, Naeem

    2017-03-01

    Botox injection in bladder wall is increasingly used in urology for over active bladder and neurogenic bladder. Aim of this audit is to assess the incidence of UTI after procedure and need for routine use of pre and post procedure antibiotics. It was case notes and lab results based retrospective study of all the patients attended for intra-vesicle Botox injection. Rate of UTI's were lower in the group who received antibiotics pre and post operatively as compared to those who did not. Routine antibiotics use lowers the risk of UTI's in patients receiving intra-vesicle botox. Neurourol. Urodynam. 36:828-828, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography

    PubMed Central

    Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.

    2014-01-01

    Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257

  7. Anatomical Regional Targeted (ART) BOTOX Injection Technique: A Novel Paradigm for Migraines and Chronic Headaches

    PubMed Central

    Sanniec, Kyle; Pezeshk, Ronnie; Chung, Michael

    2016-01-01

    Summary: Migraine headaches are a debilitating disease that causes significant socioeconomic problems. One of the speculated etiologies of the generation of migraines is peripheral nerve irritation at different trigger points. The use of Onabotulinum toxin A (BOTOX), although initially a novel approach, has now been determined to be a valid treatment for chronic headaches and migraines as described in the Phase III Research Evaluating Migraine Prophylaxis Therapy trials that prompted the approval by the Food and Drug Administration for treatment of chronic migraines. The injection paradigm established by this trial was one of a broad injection pattern across large muscle groups that did not always correspond to the anatomical locations of nerves. The senior author developed the Anatomical Regional Targeted BOTOX injection paradigm as an alternative to the current injection model. This technique targets both the anatomical location of nerves known to have causal effects with migraines and the region where the pain localizes, to provide relief across a wide distribution of the peripheral nerve. This article serves as a guide to the Anatomical Regional Targeted injection technique, which, to our knowledge, is the first comprehensive BOTOX injection paradigm described in the literature for treatment of migraines that targets nerves and nerve areas rather than purely muscle groups. This technique is based on the most up-to-date anatomical and scientific studies and large-volume migraine surgery experience. PMID:28293532

  8. Urinary retention in female OAB after intravesical Botox injection: who is really at risk?

    PubMed

    Miotla, Pawel; Cartwright, Rufus; Skorupska, Katarzyna; Bogusiewicz, Michal; Markut-Miotla, Ewa; Futyma, Konrad; Rechberger, Tomasz

    2017-06-01

    Intravesical onabotulinumtoxinA (Botox) injections are effective for the treatment of idiopathic overactive bladder (OAB) symptoms. The aim of our study was to assess the predisposing factors for urinary retention in women with OAB after intravesical Botox injection. All participants were women of European descent with idiopathic OAB. OnabotulinumtoxinA (100 U) was administered in 20 intra-detrusor injections. Analysis was performed based on the results of safety assessments made during follow-up (FU) visits on weeks 2, 4 and 12, in 208 women who were treated with Botox injections for refractory OAB and who completed all FU visits. Women who required clean intermittent self-catheterisation (CISC) and those with post-void residual (PVR) greater than 200 ml were older in comparison with patients with PVR between 50 and 200 ml. Patients who required CISC were also characterised by higher parity and particularly by a higher number of vaginal deliveries. Other factors such as body mass index or comorbidities did not significantly influence PVR and the risk of CISC. Elderly and/or multiparous women are at increased risk of urinary retention after intravesical 100-U Botox injections. The risk of new onset urine retention in our study has completely disappeared 2 weeks after Botox injections. Based on our results of the way in which the PVRs have changed over time, we can conclude that OAB patients should be optimally assessed during the first 2 weeks after Botox injections.

  9. Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.

    PubMed

    Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K

    2015-02-01

    We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.

  10. Botox

    MedlinePlus

    ... Category: Share: Yes No, Keep Private Botox Share | Botulinum toxin type A (trade name: Botox) is an injectable ... is for educational purposes only and is the property of the American Osteopathic College of Dermatology. It ...

  11. Ultrasound guided therapeutic injections of the cervical spine and brachial plexus.

    PubMed

    Cormick, Wes

    2014-02-01

    Introduction : Recent applications in ultrasound imaging include ultrasound assessment and ultrasound guided therapeutic injections of the spine and brachial plexus. Discussion : Ultrasound is an ideal modality for these regions as it allows accurate safe and quick injection of single or multiple sites. It has the added advantages of lack of ionising radiation, and can be done without requiring large expensive radiology equipment. Conclusion : Brachial plexus pathology may be present in patients presenting for shoulder symptoms where very little is found at imaging the shoulder. It is important to understand the anatomy and normal variants that may exist to be able to recognise when pathology is present. When pathology is demonstrated it is easy to do a trial of therapy with ultrasound guided injection of steroid around the nerve lesion. This review will outline the normal anatomy and variants and common pathology, which can be amenable to ultrasound guided injection of steroid.

  12. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    PubMed Central

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  13. Ultrasound-guided piriformis muscle injection. A new approach.

    PubMed

    Bevilacqua Alén, E; Diz Villar, A; Curt Nuño, F; Illodo Miramontes, G; Refojos Arencibia, F J; López González, J M

    2016-12-01

    Piriformis syndrome is an uncommon cause of buttock and leg pain. Some treatment options include the injection of piriformis muscle with local anesthetic and steroids. Various techniques for piriformis muscle injection have been described. Ultrasound allows direct visualization and real time injection of the piriformis muscle. We describe 5 consecutive patients, diagnosed of piriformis syndrome with no improvement after pharmacological treatment. Piriformis muscle injection with local anesthetics and steroids was performed using an ultrasound technique based on a standard technique. All 5 patients have improved their pain measured by numeric verbal scale. One patient had a sciatic after injection that improved in 10 days spontaneously. We describe an ultrasound-guided piriformis muscle injection that has the advantages of being effective, simple, and safe. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Ultrasound-guided injection for plantar fasciitis: A brief review

    PubMed Central

    Nair, AS; Sahoo, RK

    2016-01-01

    Plantar fasciitis (PF) is a distressing condition experienced by many patients. Although self-limiting, it tends to become a chronic ailment if the precipitating factors are not addressed. One of the modality of treating PF is intra-lesional corticosteroid injection. This was done using palpation technique earlier but nowadays many specialists use ultrasound (US) imaging as a guide to give injection accurately instead of inadvertently damaging the plantar fascia or injecting into surrounding soft tissue, both of which can have serious implications. We did a literature search in Medline, Scopus, and Embase databases to find out articles describing US-guided corticosteroid injection for treating PF and whether guided injection was effective than injection given by palpation. PMID:27833490

  15. Effect of Botox injection at the bladder neck in boys with bladder dysfunction after valve ablation.

    PubMed

    Mokhless, Ibrahim; Zahran, Abdel-Rahman; Saad, Ashraf; Yehia, Mohamed; Youssif, Mohamed E

    2014-10-01

    After posterior urethral valve ablation, some boys are still have a hostile bladder. We conducted a prospective randomized study to determine if Botox injection at the bladder neck will help improve vesical dysfunction in this subgroup of boys or not. Twenty boys with history of posterior urethral valve ablation and severe bladder dysfunction with a mean age of 16 months were studied. Cases were further randomized into two groups. Group I (study group) had endoscopic injection of a single dose of 100 IU of Botox into the hypertrophied bladder neck at 3, 6, and 9 o'clock. Group II (control group) patients with the same parameters had urethroscopy to exclude residual valves. Both groups had the standard conservative treatment. Cases were followed after 6 months of initiating the management protocol. This includes laboratory studies (urine culture and sensitivity, blood urea nitrogen, serum creatinine), ultrasound of the urinary tract. Voiding cysto-urethrogram and urodynamic study (pressure flow study). There was no statistical difference in both groups regarding rate of urinary tract infection, improvement of hydronephrosis, resolution of vesico-ureteral reflux, creatinine level at the start or at the end of the study. Urodynamic parameters revealed an increase in cystometric capacity in both groups at the end of the study but without statistical difference. The mean voiding pressure reduced significantly in both groups but without statistical difference. Temporarily abolishing the effect of bladder neck by Botox injection does not seem to improve the outcome of those boys who had a severe voiding dysfunction after valve ablation. Copyright © 2014 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  16. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  17. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    PubMed

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  18. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    PubMed

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  19. Outcome after anal intrasphincteric Botox injection in children with surgically treated Hirschsprung disease.

    PubMed

    Han-Geurts, Ingrid J M; Hendrix, Vivian C; de Blaauw, Ivo; Wijnen, Marc H W A; van Heurn, Ernest L W

    2014-11-01

    A nonrelaxing internal anal sphincter is present in a relatively large proportion of children with surgically treated Hirschsprung disease (HD) and can cause obstructive gastrointestinal symptoms. The short- and long-term outcome and adverse effects of intrasphincteric botulinum toxin (Botox) injections in children with obstruction after surgically treated HD are evaluated. The outcome of children with surgically treated HD treated with intrasphincteric Botox injections for obstructive symptoms was analyzed with a retrospective chart review between 2002 and 2013 in the University Medical Centers of Maastricht and Nijmegen. A total of 33 patients were included. The median time of follow-up was 7.3 years (range 1-24). A median of 2 (range 1-5) injections were given. Initial improvement was achieved in 76%, with a median duration of 4.1 months (range 1.7-58.8). Proportion of children hospitalized for enterocolitis decreased after treatment from 19 to 7. A good long-term response was found in 49%. Two children experienced complications: transient pelvic muscle paresis with impairment of walking. In both children symptoms resolved within 4 months without treatment. Intrasphincteric Botox injections in surgically treated HD are an effective long-term therapy in approximately half of our patients with obstructive symptoms. The possibility of adverse effects should be noticed.

  20. A technical report on ultrasound-guided scapulocostal syndrome injection.

    PubMed

    McCarthy, C; Harmon, D

    2016-08-01

    We describe a case report and technique for using an ultrasound scanner and a linear transducer to guide serratus posterior superior (SPS) muscle injection. A 43-year-old female presented with chronic pain centered under the right upper portion of her scapula impacting her activities of daily living. For the ultrasound-guided SPS muscle injection, the patient was placed in the prone position. The transducer was oriented in a transverse orientation at the level of the C6-T1 vertebrae. Here the SPS muscle attaches to the lower portion of the ligament nuchae and the intervening interspinous ligaments. The muscle fibers run inferiorly and laterally to attach to the 2nd-5th ribs which were identified along with the lateral portion of the serratus posterior superior muscle which is covered by the scapula. Real-time imaging was used to direct a spinal needle into the trigger points of the SPS muscle, where solution was injected under direct vision. The patient's pain symptoms improved significantly. Serratus posterior superior injection can confirm a diagnosis of scapulocostal syndrome and be therapeutically beneficial.

  1. Outcomes of Ultrasound-Guided Thrombin Injection of Nongroin Arterial Pseudoaneurysms.

    PubMed

    Valesano, Johnathan C; Schmitz, John J; Kurup, A Nicholas; Schmit, Grant D; Moynagh, Michael R; Atwell, Thomas D; Lewis, Bradley D; Lee, Robert A; Callstrom, Matthew R

    2017-08-01

    To evaluate success and complication rates of percutaneous ultrasound-guided thrombin injection of nongroin pseudoaneurysms (PSAs). Retrospective review of a prospectively maintained institutional database yielded 39 cases of arterial PSAs occurring at nongroin sites that were treated with percutaneous ultrasound-guided thrombin injection between 2000 and 2016 (average patient age 69.2 y ± 14.0). Of PSAs, 74.4% (29/39) arose in the upper extremities, and 92.3% (36/39) were iatrogenic. The brachial artery was the most commonly affected vessel (51.3% [20/39]), and arterial access was the most common cause (56.4% [22/39]). Average overall PSA size was 2.4 cm (range, 0.5-7.2 cm); average amount of thrombin injected was 320 IU (range, 50-2,000 IU). Technical success was defined as absence of flow within the PSA immediately after thrombin injection. Treatment success was defined as sustained thrombosis on follow-up imaging obtained at 1-3 days after treatment. Technical and treatment success rates of thrombin injections were 100% (39/39) and 84.8% (28/33), respectively. Longer term follow-up imaging (average 71 d; range, 12-201 d) was available for 7 of the treatment successes with 100% (7/7) showing sustained thrombosis. Comparing treatment successes and failures, there was no significant difference in average PSA size (2.3 cm vs 2.0 cm, P = .51) or average amount of thrombin injected (360 IU vs 180 IU, P = .14). There were no complications. Ultrasound-guided thrombin injection is a safe, efficacious treatment option for PSAs arising in nongroin locations. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  2. Interarytenoid muscle botox injection for treatment of adductor spasmodic dysphonia with vocal tremor.

    PubMed

    Kendall, Katherine A; Leonard, Rebecca J

    2011-01-01

    Up to one-third of patients presenting with adductor spasmodic dysphonia will have an associated vocal tremor. These patients may not respond fully to treatment using thyroarytenoid (TA) muscle botulinum toxin (Botox) injection. Treatment failures are attributed to the involvement of multiple muscle groups in the tremor. This study evaluates the results of combined interarytenoid (IA) and TA muscle Botox injection in a group of 27 patients with adductor spasmodic dysphonia and vocal tremor and in four patients with severe vocal tremor alone. Patient-satisfaction data were reviewed retrospectively. Pre- and postinjection acoustic data were collected prospectively. Acoustic measures of fundamental frequency and cycle-by-cycle variability in frequency (jitter) and intensity (shimmer) were obtained from 15 patients' sustained vowel productions. Measures were collected after TA muscle injection, alone, and after combined TA and IA (TA+IA) muscle injections. In addition, two experienced voice clinicians blindly assessed tremor severity from recordings made for each patient in the two conditions. Patients were also queried regarding their satisfaction with the results of the injections and whether they desired to continue receiving TA+IA treatment. Significant improvement in all acoustic measures except for % jitter was observed after the TA+IA muscle injections. Listeners identified voice samples after TA+IA muscle injections as demonstrating less tremor in 73% of the paired comparisons. Sixty-seven percent of the patients with spasmodic dysphonia and vocal tremor wished to continue to receive IA muscle injections. Only one patient with severe vocal tremor wished to continue with injections. The addition of an IA muscle Botox injection to the treatment of patients with a combination adductor spasmodic dysphonia and vocal tremor may improve voice outcomes. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  3. Adverse testicular effects of Botox® in mature rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Breikaa, Randa M.; Mosli, Hisham A.; Nagy, Ayman A.

    Botox® injections are taking a consistently increasing place in urology. Intracremasteric injections, particularly, have been applied for cryptorchidism and painful testicular spasms. Studies outlining their safety for this use are, however, scanty. Thus, the present study aimed at evaluating possible testicular toxicity of Botox® injections and their effect on male fertility. Mature rats were given intracremasteric Botox® injections (10, 20 and 40 U/kg) three times in a two-week interval. Changes in body and testes weights were examined and gonadosomatic index compared to control group. Semen quality, sperm parameters, fructose, protein, cholesterol and triglycerides contents were assessed. Effects on normal testicularmore » function were investigated by measuring testosterone levels and changes in enzyme activities (lactate dehydrogenase-X and acid phosphatase). To draw a complete picture, changes in oxidative and inflammatory states were examined, in addition to the extent of connective tissue deposition between seminiferous tubules. In an attempt to have more accurate information about possible spermatotoxic effects of Botox®, flowcytometric analysis and histopathological examination were carried out. Botox®-injected rats showed altered testicular physiology and function. Seminiferous tubules were separated by dense fibers, especially with the highest dose. Flowcytometric analysis showed a decrease in mature sperms and histopathology confirmed the findings. The oxidative state was, however, comparable to control group. This study is the first to show that intracremasteric injections of Botox® induce adverse testicular effects evidenced by inhibited spermatogenesis and initiation of histopathological changes. In conclusion, decreased fertility may be a serious problem Botox® injections could cause. - Highlights: • Botox® injections are the trend nowadays, for both medical and non-medical uses. • They were recently suggested for cryptorchidism and

  4. Ultrasound-guided thrombin injection of genicular artery pseudoaneurysm.

    PubMed

    Rachakonda, Aditya; Qato, Khalil; Khaddash, Tamim; Carroccio, Alfio; Pamoukian, Vicken; Giangola, Gary

    2015-07-01

    Pseudoaneurysm is a rare complication after arthroscopic procedures involving the knee. A 38-year-old man presented 1 month after right-knee arthroscopy with a 2-cm pulsating mass on the medial side of the right knee. Duplex ultrasound evaluation revealed 2.5 × 2.1-cm pseudoaneurysm just distal to the patella with arterialized flow communicating with the inferior medial genicular artery. Ultrasound-guided thrombin injection was performed in an office setting, and the resolution of active flow within the pseudoaneurysm was confirmed with duplex ultrasonography. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Ultrasound-guided platelet-rich plasma injection for distal biceps tendinopathy.

    PubMed

    Barker, Scott L; Bell, Simon N; Connell, David; Coghlan, Jennifer A

    2015-04-01

    Distal biceps tendinopathy is an uncommon cause of elbow pain. The optimum treatment for cases refractory to conservative treatment is unclear. Platelet-rich plasma has been used successfully for other tendinopathies around the elbow. Six patients with clinical and radiological evidence of distal biceps tendinopathy underwent ultrasound-guided platelet-rich plasma (PRP) injection. Clinical examination findings, visual analogue score (VAS) for pain and Mayo Elbow Performance scores were recorded. The Mayo Elbow Performance Score improved from 68.3 (range 65 to 85) (fair function) to 95 (range 85 to 100) (excellent function). The VAS at rest improved from a mean of 2.25 (range 2 to 5) pre-injection to 0. The VAS with movement improved from a mean of 7.25 (range 5 to 8) pre-injection to 1.3 (range 0 to 2). No complications were noted. Ultrasound-guided PRP injection appears to be a safe and effective treatment for recalcitrant cases of distal biceps tendinopathy. Further investigation with a randomized controlled trial is needed to fully assess its efficacy.

  6. Ultrasound-guided platelet-rich plasma injection for distal biceps tendinopathy

    PubMed Central

    Bell, Simon N; Connell, David; Coghlan, Jennifer A

    2015-01-01

    Background Distal biceps tendinopathy is an uncommon cause of elbow pain. The optimum treatment for cases refractory to conservative treatment is unclear. Platelet-rich plasma has been used successfully for other tendinopathies around the elbow. Methods Six patients with clinical and radiological evidence of distal biceps tendinopathy underwent ultrasound-guided platelet-rich plasma (PRP) injection. Clinical examination findings, visual analogue score (VAS) for pain and Mayo Elbow Performance scores were recorded. Results The Mayo Elbow Performance Score improved from 68.3 (range 65 to 85) (fair function) to 95 (range 85 to 100) (excellent function). The VAS at rest improved from a mean of 2.25 (range 2 to 5) pre-injection to 0. The VAS with movement improved from a mean of 7.25 (range 5 to 8) pre-injection to 1.3 (range 0 to 2). No complications were noted. Discussion Ultrasound-guided PRP injection appears to be a safe and effective treatment for recalcitrant cases of distal biceps tendinopathy. Further investigation with a randomized controlled trial is needed to fully assess its efficacy. PMID:27582965

  7. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  8. Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity

    PubMed Central

    Sconfienza, L.M.; Perrone, N.; Lacelli, F.; Lentino, C.; Serafini, G.

    2008-01-01

    Purpose Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. Method and materials The ultrasound-guided technique for BTX-A injection was used on 10 patients. The needle was inserted into the muscle belly at an angle of 45° along the longitudinal axis of the muscle when allowed by patient's condition. Results In all cases, the iliopsoas muscle was easily identified and both the iliac and psoas components were assessed. Introduction of the needle and drug injection were entirely carried out under ultrasonographic guidance. The procedure was successful in all patients, even in those with a high-grade spasticity, and general anesthesia was not required. Conclusions This ultrasound-guided technique allows accurate guidance for the injection of BTX-A, and it can be considered as an alternate supportive therapy in patients with spasticity and dystonia. PMID:23396653

  9. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    PubMed Central

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  10. Gestrinone combined with ultrasound-guided aspiration and ethanol injection for treatment of chocolate cyst of ovary.

    PubMed

    Wu, Xiaoyun; Xu, Yun

    2015-05-01

    The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  11. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    PubMed

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  12. Is ultrasound-guided injection more effective in chronic subacromial bursitis?

    PubMed

    Hsieh, Lin-Fen; Hsu, Wei-Chun; Lin, Yi-Jia; Wu, Shih-Hui; Chang, Kae-Chwen; Chang, Hsiao-Lan

    2013-12-01

    Although ultrasound (US)-guided subacromial injection has shown increased accuracy in needle placement, whether US-guided injection produces better clinical outcome is still controversial. Therefore, this study aimed to compare the efficacy of subacromial corticosteroid injection under US guidance with palpation-guided subacromial injection in patients with chronic subacromial bursitis. Patients with chronic subacromial bursitis were randomized to a US-guided injection group and a palpation-guided injection group. The subjects in each group were injected with a mixture of 0.5 mL dexamethasone suspension and 3 mL lidocaine into the subacromial bursa. The primary outcome measures were the visual analog scale for pain and active and passive ranges of motion of the affected shoulder. Secondary outcome measures were the Shoulder Pain and Disability Index, the Shoulder Disability Questionnaire, and the 36-item Short-Form Health Survey (SF-36). The primary outcome measures were evaluated before, immediately, 1 wk, and 1 month after the injection; the secondary outcome measures were evaluated before, 1 wk, and 1 month after the injection. Of the 145 subjects screened, 46 in each group completed the study. Significantly greater improvement in passive shoulder abduction and in physical functioning and vitality scores on the SF-36 were observed in the US-guided group. The pre- and postinjection within-group comparison revealed significant improvement in the visual analog scale for pain and range of motion, as well as in the Shoulder Pain and Disability Index, Shoulder Disability Questionnaire, and SF-36 scores, in both groups. The US-guided subacromial injection technique produced significantly greater improvements in passive shoulder abduction and in some items of the SF-36. US is effective in guiding the needle into the subacromial bursa in patients with chronic subacromial bursitis.

  13. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    PubMed

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  14. Vaginismus: review of current concepts and treatment using botox injections, bupivacaine injections, and progressive dilation with the patient under anesthesia.

    PubMed

    Pacik, Peter T

    2011-12-01

    Vaginismus is a poorly understood condition affecting approximately 1-7% of females worldwide. This article aims to bring attention to this disorder and to review the use of Botox injections to treat these patients. Vaginismus, also known as vaginal penetration disorder, is an aversion to any form of vaginal penetration as a result of painful attempts and a fear of anticipated pain. It is involuntary and uncontrolled and functions much the same as any reflex to avoid injury. It is the most common reason for unconsummated marriages. The etiology is thought to be unknown. Numerous papers note a history of religious or strict sexual upbringing or aversion to penetration because of perceived pain and bleeding with first-time intercourse. Sexual molestation may be more prevalent in this group of patients. The Lamont classification is very helpful in stratifying these patients for treatment. Lamont grade 5 vaginismus is introduced. Vaginal Botox injections for the treatment of vaginismus has received increasing attention since the technique was first described in a 1997 case report. Plastic surgeons worldwide with their experience using Botox are well positioned to learn more about this relatively unknown entity and render treatment.

  15. Intrathecal Spread of Injectate Following an Ultrasound-Guided Selective C5 Nerve Root Injection in a Human Cadaver Model.

    PubMed

    Falyar, Christian R; Abercrombie, Caroline; Becker, Robert; Biddle, Chuck

    2016-04-01

    Ultrasound-guided selective C5 nerve root blocks have been described in several case reports as a safe and effective means to anesthetize the distal clavicle while maintaining innervation of the upper extremity and preserving diaphragmatic function. In this study, cadavers were injected with 5 mL of 0.5% methylene blue dye under ultrasound guidance to investigate possible proximal and distal spread of injectate along the brachial plexus, if any. Following the injections, the specimens were dissected and examined to determine the distribution of dye and the structures affected. One injection revealed dye extended proximally into the epidural space, which penetrated the dura mater and was present on the spinal cord and brainstem. Dye was noted distally to the divisions in 3 injections. The anterior scalene muscle and phrenic nerve were stained in all 4 injections. It appears unlikely that local anesthetic spread is limited to the nerve root following an ultrasound-guided selective C5 nerve root injection. Under certain conditions, intrathecal spread also appears possible, which has major patient safety implications. Additional safety measures, such as injection pressure monitoring, should be incorporated into this block, or approaches that are more distal should be considered for the acute pain management of distal clavicle fractures.

  16. Ultrasound-guided percutaneous injection of methylene blue to identify nerve pathology and guide surgery.

    PubMed

    Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel

    2015-09-01

    OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.

  17. Effectiveness of ultrasound-guided injections combined with shoulder exercises in the treatment of subacromial adhesive bursitis.

    PubMed

    Gasparre, Giuseppe; Fusaro, Isabella; Galletti, Stefano; Volini, Silvia; Benedetti, Maria Grazia

    2012-05-01

    The aim of this study was to evaluate whether the association of exercises for the shoulder with ultrasound-guided injection into the bursa significantly improves the treatment outcome in adhesive bursitis. Two groups of 35 patients, one treated with ultrasound-guided injection (UGI) and the other one with ultrasound-guided injection and home exercise program (UGI-exercise) for 1 month, were assessed for pain and shoulder function before treatment, 1 and 3 months post-treatment. Fourteen patients in UGI group and 23 patients in the UGI-exercises group were completely free of pain after 1 month (p = 0.031). At 3 months' follow-up, patients in the UGI-exercise group showed a significant improvement with respect to the other group (p = 0.005). No differences were found in function assessment. The UGI combined with shoulder exercises in the treatment of subacromial adhesive bursitis is effective to ensure a more frequent complete pain relief in the medium term.

  18. Long-term follow-up of ultrasound-guided botulinum toxin-A injections for sialorrhea in neurological dysphagia.

    PubMed

    Barbero, Pierangelo; Busso, Marco; Tinivella, Marco; Artusi, Carlo Alberto; De Mercanti, Stefania; Cucci, Angele; Veltri, Andrea; Avagnina, Paolo; Calvo, Andrea; Chio', Adriano; Durelli, Luca; Clerico, Marinella

    2015-12-01

    Literature provides reports only of a limited follow-up single injection of botulinum toxin-A (BoNT-A) in patients with sialorrhea. The aim of our study is to evaluate the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for severe sialorrhea secondary to neurological dysphagia. We enrolled 38 severe adult sialorrhea patients referred consecutively to the neurology unit and performed bilateral parotid and submandibular gland BoNT-A injections under ultrasound guidance. The outcomes of the study were reduction of sialorrhea, duration of therapeutic effect, and subjective patient- and caregiver-reported satisfaction. A total of 113 BoNT-A administrations were given during the study period with a mean duration of follow-up of 20.2 ± 4.4 months. We observed a significant decrease from baseline in mean number of daily aspirations and a significant improvement in patient- and caregiver-reported outcomes following ultrasound-guided BoNT-A injections (p < 0.001 vs baseline for all comparisons) and the mean duration of the efficacy was 5.6 ± 1 months. No major treatment-related adverse events occurred and a low incidence of minor adverse events was reported. This study confirms the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for sialorrhea, regardless of the causative neurological disorder. These results should encourage the use of BoNT-A in the treatment of severe sialorrhea and highlight the role of ultrasound guidance to obtain optimal results in terms of safety and reproducible outcomes.

  19. Ultrasound guided intra-articular ketorolac versus corticosteroid injection in osteoarthritis of the hip: a retrospective comparative study.

    PubMed

    Park, Ki Deok; Kim, Tai Kon; Bae, Byung Woo; Ahn, JaeKi; Lee, Woo Yong; Park, Yongbum

    2015-09-01

    Intra-articular steroid injection has been widely used in the management of symptomatic osteoarthritis; however, its frequent use is avoided since there is an increase in the incidence of articular infection and several mechanical side effects such as cartilage breakdown and loss of elasticity of the articular cartilage. For these reasons, nonsteroidal anti-inflammatory drugs instead of corticosteroids can be considered for intra-articular injection. On this basis, we investigated the effects and safety of ultrasound-guided intra-articular ketorolac versus corticosteroid injection for patients with osteoarthritis of the hip. This retrospective study included 98 patients with diagnoses of hip osteoarthritis who underwent ultrasound-guided intra-articular ketorolac or corticosteroid injection. Fifty patients who received ultrasound-guided intra-articular corticosteroid injection were administered a mixture of 0.5% lidocaine and triamcinolone. Forty-eight patients who received ultrasound-guided intra-articular ketorolac injection were administered 0.5% lidocaine and ketorolac. Outcome measurement was assessed using the Harris hip score and verbal numeric pain scale, which were evaluated before the injections and at 1, 3 and 6 months following the injection. Univariate analysis (using the x (2) test) and multiple logistic regression analysis were performed to evaluate the relationship between the possible outcome predictors (injected medications, patients' age, gender, pain duration and Kellgren-Lawrence classification) and the therapeutic effects. The Harris hip score and verbal numeric pain scale were improved at 1, 3 and 6 months after the injection in both groups. No statistical differences in the Harris hip score and verbal numeric pain scale were observed between the groups. The success rate was also not significantly different among the time periods of 1, 3 and 6 months. Multiple logistic regression and univariate analysis showed that injected medications

  20. Ultrasound-guided corticosteroid injection therapy for juvenile idiopathic arthritis: 12-year care experience.

    PubMed

    Young, Cody M; Shiels, William E; Coley, Brian D; Hogan, Mark J; Murakami, James W; Jones, Karla; Higgins, Gloria C; Rennebohm, Robert M

    2012-12-01

    Intra-articular corticosteroid injections are a safe and effective treatment for patients with juvenile idiopathic arthritis. The potential scope of care in ultrasound-guided corticosteroid therapy in children and a joint-based corticosteroid dose protocol designed to optimize interdisciplinary care are not found in the current literature. The purpose of this study was to report the spectrum of care, technique and safety of ultrasound-guided corticosteroid injection therapy in patients with juvenile idiopathic arthritis and to propose an age-weight-joint-based corticosteroid dose protocol. A retrospective analysis was performed of 198 patients (ages 21 months to 28 years) referred for treatment of juvenile idiopathic arthritis with corticosteroid therapy. Symptomatic joints and tendon sheaths were treated as prescribed by the referring rheumatologist. An age-weight-joint-based dose protocol was developed and utilized for corticosteroid dose prescription. A total of 1,444 corticosteroid injections (1,340 joints, 104 tendon sheaths) were performed under US guidance. Injection sites included small, medium and large appendicular skeletal joints (upper extremity 497, lower extremity 837) and six temporomandibular joints. For patients with recurrent symptoms, 414 repeat injections were performed, with an average time interval of 17.7 months (range, 0.5-101.5 months) between injections. Complications occurred in 2.6% of injections and included subcutaneous tissue atrophy, skin hypopigmentation, erythema and pruritis. US-guided corticosteroid injection therapy provides dynamic, precise and safe treatment of a broad spectrum of joints and tendon sheaths throughout the entire pediatric musculoskeletal system. An age-weight-joint-based corticosteroid dose protocol is effective and integral to interdisciplinary care of patients with juvenile idiopathic arthritis.

  1. Factors influencing discomfort during anterior ultrasound-guided injection for hip arthrography.

    PubMed

    Hsu, Yi-Chih; Wu, Yu-Cheng; Kao, Hao-Lun; Pan, Ru-Yu; Lee, Meei-Shyuan; Huang, Guo-Shu

    2013-09-01

    Although ultrasound (US)-guided injection techniques for magnetic resonance arthrography of the hip have been used with increasing frequency to diagnose internal joint derangements, little is known about patient tolerance, which is relevant information for patients. The objective of this study was to evaluate prospectively the association between possible influencing factors and discomfort felt during the performance of anterior US-guided injection techniques targeting the femoral head-neck junction during hip arthrography. Forty-four consecutive patients (21 women and 23 men; mean age, 41 years) undergoing magnetic resonance hip arthrography were sequentially assigned to receive injection alternating between fixed and freehand US-guided injection. Discomfort was assessed using a visual analog scale and relative ratings. Patient body mass index, extra-articular contrast leakage, the duration of the procedure, the needle advancement distance, and the fixed trajectory of the needle were assessed. Pearson's correlation coefficients and multiple logistic regression analysis were used to determine the association. Puncture was successfully accomplished in all cases, and no relevant complications were reported. The only significant relationships were between discomfort and the time required for needle manipulation (r = 0.8) and fixed US-guided injection (r = 0.6; p < 0.001). Compared with the freehand technique, the fixed technique resulted in significantly less pain and took significantly less time to perform (p < 0.001). The procedure time during needle manipulation in the fixed US-guided injections (4.0 ± 0.9 seconds) was significantly less than that in the freehand US-guided injections (19.4 ± 17.6 seconds; p < 0.001). No significant relationships were found between discomfort and other parameters (r < 0.3, p > 0.05). The procedure time appears to be the most important factor influencing patient discomfort. Fixed US-guided injection is a time

  2. Botulinum toxin injection - larynx

    MedlinePlus

    Injection laryngoplasty; Botox - larynx: spasmodic dysphonia-BTX; Essential voice tremor (EVT)-btx; Glottic insufficiency; Percutaneous electromyography - guided botulinum toxin treatment; Percutaneous indirect laryngoscopy - guided botulinum toxin treatment; ...

  3. A reliable technique for ultrasound-guided perineural injection in ulnar neuropathy at the elbow.

    PubMed

    Hamscha, Ulrike M; Tinhofer, Ines; Heber, Stefan; Grisold, Wolfgang; Weninger, Wolfgang J; Meng, Stefan

    2017-08-01

    Ulnar neuropathy at the elbow (UNE) is a common peripheral compression neuropathy and, in most cases, occurs at 2 sites, the retroepicondylar groove or the cubital tunnel. With regard to a potential therapeutic approach with perineural corticosteroid injection, the aim of this study was to evaluate the distribution of injection fluid applied at a standard site. We performed ultrasound-guided (US-guided) perineural injections to the ulnar nerve halfway between the olecranon and the medial epicondyle in 21 upper limbs from 11 non-embalmed cadavers. In anatomic dissection we investigated the spread of injected ink. Ink was successfully injected into the perineural sheath of the ulnar nerve in all 21 cases (cubital tunnel: 21 of 21; retroepicondylar groove: 19 of 21). US-guided injection between the olecranon and the medial epicondyle is a feasible and safe method to reach the most common sites of ulnar nerve entrapment. Muscle Nerve 56: 237-241, 2017. © 2016 Wiley Periodicals, Inc.

  4. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    PubMed

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  5. Endobronchial ultrasound-guided transbronchial needle injection for local control of recurrent non-small cell lung cancer.

    PubMed

    Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.

  6. Ultrasound-guided Interdigital Neuroma Injections: Short-term Clinical Outcomes after a Single Percutaneous Injection—Preliminary Results

    PubMed Central

    Adler, Ronald S.; Ciavarra, Gina A.; Pavlov, Helene

    2006-01-01

    Purpose To describe the procedure of ultrasound-guided Morton’s neuroma and recurrent stump neuroma injections and early clinical outcomes after a single injection. Materials and Methods Retrospective review of 44 percutaneous ultrasound-guided neuroma injections in 24 patients who had completed clinical outcomes questionnaires. A 10-point pain scale [scale of 1 (no pain) to 10 (severe pain)] in a 7-day pain log format was distributed to patients at the time percutaneous neuroma injection was performed. Results Neuromas were clearly visualized with sonography as hypoechoic nodules and were distinguishable from other causes of forefoot pain, such as metatarsophalangeal joint synovitis and intermetatarsal bursae. The sizes of the neuromas injected ranged between 4 and 19 mm. Postinjection, all neuromas displayed increased echogenicity and/or the appearance of fluid surrounding it, confirming localization of the therapeutic mixture. We arbitrarily subdivided the pain ratings into symptomatic (greater than 4) and asymptomatic (less than or equal to 4) for statistical analysis. Average pain level pre injection was 5.2 and average pain level was 3.7 at 7 days post single injection, with 62% of the initially symptomatic patients asymptomatic on day 7 (p < 0.000001). Overall, 76% of the total number of neuromas injected once were asymptomatic on day 7. Conclusion Ultrasound can be used to accurately target Morton’s neuromas and, therefore, appropriately direct therapeutic interventions, with good short-term clinical results. PMID:18751769

  7. Botox therapy for ischemic digits.

    PubMed

    Neumeister, Michael W; Chambers, Christopher B; Herron, Margo S; Webb, Kelli; Wietfeldt, Joel; Gillespie, Jessica N; Bueno, Rueben A; Cooney, Carisa M

    2009-07-01

    Treating patients with Raynaud's phenomenon who have chronic pain and ulcerations is extremely challenging. Unrelenting pain can lead to dysfunction and disuse, rendering the patient debilitated and/or chronically depressed. Pharmacologic vasodilators and surgical sympathectomies offer variable benefits. Outcomes of symptomatic patients treated with botulinum toxin type A (Botox) injections for Raynaud's phenomenon are presented. A retrospective study focused on patient outcomes was performed on 19 patients diagnosed with Raynaud's phenomenon. Patients suffered from chronic ischemic hand pain. All patients had vascular studies to rule out occlusive disease. Fifty to 100 units of Botox were injected into the palm around each involved neurovascular bundle. Preinjection and postinjection laser Doppler scanning was performed on most patients to measure blood flow. Sixteen of 19 patients (84 percent) reported pain reduction at rest. Thirteen patients reported immediate relief; three reported more gradual pain reduction over 1 to 2 months. Three patients had no or minimal pain relief. Tissue perfusion results demonstrated a marked change in blood flow (-48.15 percent to 425 percent) to the digits. All patients with chronic finger ulcers healed within 60 days. Most patients [n = 12 (63 percent)] remained pain-free (13 to 59 months) with a single-injection schedule. Four patients (21 percent) required repeated injections because of recurrent pain. Vascular function is abnormal in patients with Raynaud's phenomenon. Although its mechanism is unknown, Botox yielded a distinct improvement in perfusion and reduction in pain in patients failing conservative management. Continued research may lead to more specific and reliable treatment for Raynaud's patients.

  8. Effects of Ultrasound-guided intra-articular ketorolac injection with capsular distension.

    PubMed

    Ahn, Jae Ki; Kim, Jongwoo; Lee, Sang Jae; Park, Yongbum; Bae, Byung; Lee, Woo

    2015-01-01

    Frozen shoulder is a painful condition with gradual onset and loss of range of motion in the glenohumeral joint. To investigate the efficacy of ultrasound(US)-guided intra-articular (IA) ketorolac injection with capsular distension compared with steroid injection alone in patients with frozen shoulder by assessing pain relief, functional improvements, and range of motion at 1,3 and 6 months after the last injections. Between January 2009 and December 2012, 121 patient were treated with US-guided IA steroid injection or IA ketorolac injection with capsular distension for frozen shoulder. Patients (n= 57) of US-guided IA steroid injection group were administered with a mixture of 0.5% lidocaine (4 ml) plus triamcinolone (40 mg/ml; 1 ml) and patients (n= 64) of US-guided IA ketorolac injection with capsular distension group were administered by using 0.5% lidocaine (19 mL) plus ketorolac (30 mg/ml; 1 mL) for capsular distension. Outcome measurement was assessed by Shoulder Pain and Disability Index (SPADI), Verbal Numeric pain Scale (VNS) and passive range of motion (ROM) before injections and at 1, 3 and 6 months after the last injections. We regarded the outcomes as a success if patients obtained significant pain relief (as measured by > 50% improvement in the VNS score and 20 point improvement in the SPASI) at 1, 3 and 6 months after the last injections. SPADI, VNS and passive ROM were improved 1, 3 and 6 months after the last injections in both groups. The statistical differences were not observed in SPADI, VNS between groups (p< 0.05). Successful treatment rate were not significantly different between the groups as well as in 1, 3 and 6 month outcomes. However, greater improvement was found in a matter of range of motion in patients receiving IA ketorolac injection with capsular distension than participants receiving US-guided IA steroid injection alone. Significant differences in improvement at 3 and 6 months were observed for shoulder passive abduction and

  9. A prospective, randomized comparison between single- and multiple-injection techniques for ultrasound-guided subgluteal sciatic nerve block.

    PubMed

    Yamamoto, Hiroto; Sakura, Shinichi; Wada, Minori; Shido, Akemi

    2014-12-01

    It is believed that local anesthetic injected to obtain circumferential spread around nerves produces a more rapid onset and successful blockade after some ultrasound-guided peripheral nerve blocks. However, evidence demonstrating this point is limited only to the popliteal sciatic nerve block, which is relatively easy to perform by via a high-frequency linear transducer. In the present study, we tested the hypothesis that multiple injections of local anesthetic to make circumferential spread would improve the rate of sensory and motor blocks compared with a single-injection technique for ultrasound-guided subgluteal sciatic nerve block, which is considered a relatively difficult block conducted with a low-frequency, curved-array transducer. Ninety patients undergoing knee surgery were divided randomly into 2 groups to receive the ultrasound-guided subgluteal approach to sciatic nerve block with 20 mL of 1.5% mepivacaine with epinephrine. For group M (the multiple-injection technique), the local anesthetic was injected to create circumferential spread around the sciatic nerve without limitation on the number of needle passes. For group S (the single-injection technique), the number of needle passes was limited to 1, and the local anesthetic was injected to create spread along the dorsal surface of the sciatic nerve, during which no adjustment of the needle tip was made. Sensory and motor blockade were assessed in double-blind fashion for 30 minutes after completion of the block. The primary outcome was sensory blockade of all sciatic components tested, including tibial, superficial peroneal, and sural nerves at 30 minutes after injection. Data from 86 patients (43 in each group) were analyzed. Block execution took more time for group M than group S. The proportion of patients with complete sensory blockade of all sciatic components at 30 minutes after injection was significantly larger for group M than group S (41.9% vs 16.3%, P = 0.018). Complete motor blockade of

  10. Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

    PubMed

    Rutten, Matthieu J C M; Collins, James M P; Maresch, Bas J; Smeets, Jacques H J M; Janssen, Caroline M M; Kiemeney, Lambertus A L M; Jager, Gerrit J

    2009-03-01

    To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and posterior approach (USp), fluoroscopic-guided anterior (FLa) and posterior (FLp) approach were used. Number of injection attempts, effect of contrast leakage on diagnostic quality, and total room, radiologist and procedure times were measured. Pain was documented with a visual analogue scale (VAS) pain score. Access to the joint was achieved in all patients. A successful first attempt significantly occurred more often with US (94%) than with fluoroscopic guidance (72%). Leakage of contrast medium did not cause interpretative difficulties. With US guidance mean room, procedure and radiologist times were significantly shorter (p < 0.001). The USa approach was rated with the lowest pre- and post-injection VAS scores. The four image-guided injection techniques are successful in injection of contrast material into the glenohumeral joint. US-guided injections and especially the anterior approach are significantly less time consuming, more successful on the first attempt, cause less patient discomfort and obviate the need for radiation and iodine contrast.

  11. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model.

    PubMed

    Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul

    2015-11-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.

  12. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model

    PubMed Central

    Park, Gi-Young; Lee, Sang Chul

    2015-01-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340

  13. Treatment of cervical pregnancy with ultrasound-guided local methotrexate injection.

    PubMed

    Yamaguchi, M; Honda, R; Erdenebaatar, C; Monsur, M; Honda, T; Sakaguchi, I; Okamura, Y; Ohba, T; Katabuchi, H

    2017-12-01

    Cervical pregnancy (CP) is a rare type of ectopic pregnancy. While methotrexate (MTX) is generally the first-line method of choice for clinically stable women, there is still no consensus on the most appropriate treatment for this abnormal pregnancy. The aim of this study was to investigate the efficacy of a single local MTX injection under transvaginal ultrasound guidance for the initial treatment of CP and to assess post-treatment fertility. We reviewed retrospectively 15 patients with CP treated with local MTX injection under transvaginal ultrasound guidance. In all patients, the serum human chorionic gonadotropin (hCG) levels were monitored and the gestational sac was evaluated using ultrasonography after treatment. Magnetic resonance imaging (MRI) was performed as necessary. We evaluated the patients' clinical characteristics and clinical course after treatment, the efficacy of the treatment and the post-treatment fertility in patients desiring subsequent pregnancy. The median estimated gestational age at the time of MTX injection was 6 + 2 (range, 5 + 2 to 11 + 0) weeks. All 15 patients were treated successfully, without the need for blood transfusion or surgical procedures; however, three patients required an additional local MTX injection due to a poor decline in serum hCG level following the initial injection, while one patient required uterine artery embolization due to persistent vaginal bleeding and an enlarging gestational sac with blood vessels visible on contrast-enhanced MRI. The mean time following initial MTX injection for hCG normalization was 43.8 (95% CI, 33.3-54.3) days and for resumption of menses was 68.4 (95% CI, 51.9-84.9) days. Seven of the 10 women desiring subsequent pregnancy following treatment had uneventful pregnancy, one became pregnant but miscarried spontaneously at 8 weeks of gestation, one was treated by laparoscopic surgery after diagnosis of a tubal pregnancy and one did not conceive. A single, ultrasound-guided

  14. Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound.

    PubMed

    Furtado, Rita Nely Vilar; Pereira, Daniele Freitas; da Luz, Karine Rodrigues; dos Santos, Marla Francisca; Konai, Monique Sayuri; Mitraud, Sonia de Aguiar Vilela; Rosenfeld, Andre; Fernandes, Artur da Rocha Correa; Natour, Jamil

    2013-01-01

    Compare the effectiveness of ultrasound and fluoroscopy to guide intra-articular injections (IAI) in selected cases. A prospective study in our outpatient clinics at the Rheumatology Division at Universidade Federal de São Paulo (UNIFESP), Brazil, was conducted to compare the short-term (4 weeks) effectiveness of ultrasound and fluoroscopy-guided IAI in patients with rheumatic diseases. Inclusion criteria were: adults with refractory synovitis undergoing IAI with glucocorticoid. All patients had IAI performed with triamcinolone hexacetonide (20mg/ml) with varying doses according to the joint injected. A total of 71 rheumatic patients were evaluated (52 women, 44 whites). Mean age was 51.9 ± 13 years and 47 of them (66.2%) were on regular DMARD use. Analysis of the whole sample (71 patients) and hip sub-analysis (23 patients) showed that significant improvement was observed for both groups in terms of pain (P < 0.001). Global analysis also demonstrated better outcomes for patients in the FCG in terms of joint flexion (P < 0.001) and percentage change in joint flexion as compared to the USG. Likert scale score analyses demonstrated better results for the patients in the USG as compared to the FCG at the end of the study (P < 0.05). No statistically significant difference between groups was observed for any other study variable. Imaging-guided IAI improves regional pain in patients with various types of synovitis in the short term. For the vast majority of variables, no significant difference in terms of effectiveness was observed between fluoroscopy and ultrasound guided IAI.

  15. Correlation of ultrasound-guided corticosteroid injection of the quadratus femoris with MRI findings of ischiofemoral impingement.

    PubMed

    Backer, Matthew W; Lee, Kenneth S; Blankenbaker, Donna G; Kijowski, Richard; Keene, James S

    2014-09-01

    MRI findings of ischiofemoral impingement (IFI) have been described, but there is little evidence for treatment with ultrasound-guided corticosteroid injection. The purpose of this study was to evaluate the effectiveness of ultrasound-guided corticosteroid injection of the quadratus femoris muscle as a treatment of IFI syndrome and to correlate the MRI findings with injection outcome. The medical records of 61 consecutively registered subjects who underwent bony pelvis MRI in which either IFI or quadratus femoris edema was described in the radiology report were retrospectively reviewed. Subjects with MRI findings of IFI and clinical confirmation of pain that could be attributed to IFI were included and divided into injection and control groups based on clinical management. Control subjects had MRI findings and clinical symptoms suggestive of IFI but underwent conservative therapy rather than injection. The control patients had adequate follow-up and clinical documentation to determine their response to treatment. Quadratus femoris muscle edema, fat atrophy, and hamstring tendinopathy were graded from none to severe (grades 0-3). The ischiofemoral and quadratus femoris spaces were also measured. Clinical presentation was classified as typical, somewhat typical, or not typical of IFI. Injection effectiveness was determined by reported pain reduction assessed before, immediately after, and 2 weeks after the procedure with a standard 10-cm visual analog scale. Response to treatment was classified as good (reduction in pain level > 2), mild or partial (reduced by 1 or 2), or no improvement. For patients who did not return their 2-week postinjection pain surveys, injection effectiveness was determined by qualitative assessments found in their clinical notes. A Kruskal-Wallis rank sum test was used to compare effectiveness of injection between groups (p < 0.05). The Fisher exact test was used to evaluate for associations between each MRI finding and injection outcome. Of

  16. Efficacy and safety of point-of-care ultrasound-guided intra-articular corticosteroid joint injections in patients with haemophilic arthropathy.

    PubMed

    Martin, E J; Cooke, E J; Ceponis, A; Barnes, R F W; Moran, C M; Holle, S; Hughes, T H; Moore, R E; von Drygalski, A

    2017-01-01

    Intra-articular corticosteroid injections are standard of care for managing joint pain secondary to osteoarthritis or rheumatoid arthritis but are rarely used in haemophilic arthropathy. We have introduced and evaluated the efficacy and safety of ultrasound-guided corticosteroid injections for pain relief in patients with haemophilic arthropathy. Ultrasound-guided intra-articular injections performed on haemophilia patients at UCSD between March 2012 and January 2016 were analysed. Needle placement and injection (40 mg triamcinolone; 3-5 mL lidocaine) were performed with musculoskeletal ultrasound and Power Doppler. Analysis included patient demographics, joint-specific parameters such as tissue hypervascularity and effusions, pain relief, and procedure-associated complications. Forty-five injections (14 ankles, 13 elbows, 18 knees) were administered in 25 patients. Advanced arthropathy with hypervascularity and/or effusions was present in 91% and 61% of joints, respectively. Ninety-one per cent of injections resulted in pain relief which was significant in 84% (>30% reduction). Median pain score was reduced from 7 of 10 to 1 of 10 (P < 0.001), usually within 24 h. Median duration of pain relief was 8 weeks (range 1-16 weeks). Haemophilia B patients experienced longer periods of relief, and high Pettersson scores were associated with shorter duration of relief. There were no procedure-associated complications. Repeat ultrasound of eight joints within 4 weeks of injection demonstrated nearly complete resolution of hypervascularity. Point-of-care ultrasound enabled intra-articular corticosteroid injections that provided highly effective, safe, and relatively long-lasting pain relief in haemophilic arthropathy. This approach should be used to improve pain management in haemophilic arthropathy. © 2016 John Wiley & Sons Ltd.

  17. Ultrasound-guided interventional procedures around the shoulder.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria

    2016-01-01

    Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.

  18. Ultrasound-guided steroid tendon sheath injections in juvenile idiopathic arthritis: a 10-year single-center retrospective study.

    PubMed

    Peters, Shannon E; Laxer, Ronald M; Connolly, Bairbre L; Parra, Dimitri A

    2017-04-11

    The aims of this study were to: (a) Identify tendon sheaths most commonly treated with steroid injections in a pediatric patient population with Juvenile Idiopathic Arthritis (JIA); (b) Describe technical aspects of the procedure; (c) Characterize sonographic appearance of tenosynovitis in JIA; (d) Assess agreement between clinical request and sites injected. This was a 10 year single-center retrospective study (May 2006-April 2016) of patients with JIA referred by Rheumatology for ultrasound-guided tendon sheath injections. Patient demographics, clinical referral information, sonographic appearance of the tendon sheaths and technical aspects of the procedure were analyzed. There were 308 procedures of 244 patients (75% female, mean age 9.6 years) who underwent a total of 926 tendon sheath injections. Ankle tendons were most commonly injected (84.9%), specifically the tendon sheaths of tibialis posterior (22.3%), peroneus longus (20%) and brevis (19.7%). The majority of treated sites (91.9%) showed peritendinous fluid and sheath thickening on ultrasound. There were 2 minor intra-procedure complications without sequelae. A good agreement between clinical request and sites injected was observed. Ultrasound-guided tendon sheath injections with steroids are used frequently to treat patients with JIA. It is a safe intervention with a high technical success rate. The ankle region, specifically the medial compartment, is the site most commonly injected in this group of patients. The most common sonographic finding is peritendinous fluid and sheath thickening. These findings might assist clinicians and radiologists to characterize and more effectively manage tenosynovitis in patients with JIA.

  19. Ultrasound-guided therapeutic injections for neural pathology about the foot and ankle: a 4 year retrospective review.

    PubMed

    Walter, William R; Burke, Christopher J; Adler, Ronald S

    2017-06-01

    To describe a 4-year clinical experience with ultrasound-guided therapeutic perineural injections of peripheral nerves about the foot and ankle. Retrospective analysis of foot and ankle perineural injections performed between January 2012 and August 2016. Demographics, clinical indications, presence of structural pathology, immediate and interval pain relief, as well as complications were recorded. Fifty-nine therapeutic injections were performed among 46 patients, accounting for multiple injections in a single visit or multiple visits [mean age = 43 years (range 18-75), 31 female (67%) and 15 male (33%)]. Most commonly, perineural injections involved the hallux branch of the medial plantar nerve (n = 17, 22%). Least commonly, perineural injections involved the saphenous nerve (n = 3, 4%). Other injections in our series include sural (10), superficial (11) and deep (7) peroneal, medial (5) and lateral (3) plantar nerves, and the posterior tibial nerve (3). Ultrasound evaluation revealed structural abnormality associated with the nerve in 30 cases (51%)-most commonly thickening with perineural scarring (n = 14). Of 45 injections with complete documentation, immediate relief of symptoms was reported in 43 (96%) cases. Interval symptom relief was achieved in 23 injections [short term (n = 12), intermediate (n = 6), and long term (n = 5)] out of 38 for which follow-up was available (61%). Complications are rare, occurring in only one case. Ultrasound-guided perineural injections about the foot and ankle are safe and provide lasting symptomatic relief for many indications. Concomitant sonographic evaluation identifies structural abnormalities that may contribute to neuropathic symptoms, allowing targeting of injection or clinical therapy.

  20. Ultrasound-Guided Steroid Injection of the Pisotriquetral Joint: A Multidisciplinary Effort.

    PubMed

    Brose, Steven W; Montfort, Janel; Gustafson, Kenneth J; Mittebrun, Ionica; Gauriloff, Samantha; Mosher, Mary; Bourbeau, Dennis J

    2017-12-01

    From the perspective of a multidisciplinary team, the authors describe the first reported use of ultrasound guidance for steroid injection into the pisotriquetral joint to relieve wrist pain of a person with spinal cord injury undergoing acute inpatient rehabilitation. Musculoskeletal ultrasound guidance was used to improve the accuracy of a corticosteroid injection of the pisotriquetral joint and the basal thumb in a 70-year-old man with paraplegia experiencing multifocal degenerative wrist pain. There was no bleeding or bruising after the injections, and the patient reported complete pain resolution 1 wk after the injections, which continued for over 1 yr. A multidisciplinary team was key in diagnosis, selection of treatment, and evaluation of treatment effect. Corticosteroid injection of the pisotriquetral joint under ultrasound guidance can be used as a treatment modality for managing wrist pain stemming from that joint. Further investigation and studies evaluating the use of ultrasound versus other imaging modalities for injection of the wrist are indicated.

  1. Comparing the effectiveness of ultrasound-guided versus blind steroid injection in the treatment of severe carpal tunnel syndrome

    PubMed

    Karaahmet, Özgür Zeliha; Gürçay, Eda; Kara, Murat; Serçe, Azize; Kıraç Ünal, Zeynep; Çakcı, Aytül

    2017-12-19

    Background/aim: This study aimed to compare the effectiveness of ultrasound (US)-guided injection versus blind injection of corticosteroids in the treatment of carpal tunnel syndrome (CTS). Materials and methods: This prospective, randomized clinical trial included patients with severe CTS based on clinical and electrophysiological criteria. The patients were evaluated for clinical and electrophysiological parameters at baseline and 4 weeks after treatment. Symptom severity and hand function were assessed by the Boston questionnaire. The patients underwent blind injection or US-guided injection. Results: When compared with baseline, both groups showed significant improvement in Boston questionnaire scores and all electrophysiological parameters. Significant differences were observed between the groups for clinical parameters (Boston Symptom Severity Scale: P = 0.007; Functional Status Scale: P < 0.001) in favor of the US-guided group. Conclusion: This study demonstrated that both US-guided and blind injections were effective in reducing symptoms and improving hand function. US-guided injections may yield more effective clinical results in the short-term than blind injections in the treatment of patients with severe CTS.

  2. Full-length silicone insoles versus ultrasound-guided corticosteroid injection in the management of plantar fasciitis: a randomized clinical trial.

    PubMed

    Yucel, Ufuk; Kucuksen, Sami; Cingoz, Havva T; Anliacik, Emel; Ozbek, Orhan; Salli, Ali; Ugurlu, Hatice

    2013-12-01

    Plantar fasciitis often leads to disability. Optimal treatment for this clinical condition is still unknown. To compare the effectiveness of wearing a full-length silicone insole with ultrasound-guided corticosteroid injection in the management of plantar fasciitis. Randomized clinical trial. Forty-two patients with chronic unilateral plantar fasciitis were allocated randomly to have an ultrasound-guided corticosteroid injection or wear a full-length silicone insole. Data were collected before the procedure and 1 month after. The primary outcome measures included first-step heel pain via Visual Analogue Scale and Heel Tenderness Index. Other outcome measures were the Foot and Ankle Outcome Score and ultrasonographic thickness of the plantar fascia. After 1 month, a significant improvement was shown in Visual Analogue Scale, Heel Tenderness Index, Foot and Ankle Outcome Score, and ultrasonographic thickness of plantar fascia in both groups. Visual Analogue Scale scores, Foot and Ankle Outcome Score pain, Foot and Ankle Outcome Score for activities of daily living, Foot and Ankle Outcome Score for sport and recreation function, and plantar fascia thickness were better in injection group than in insole group (p < 0.05). Although both ultrasound-guided corticosteroid injection and wearing a full-length silicone insole were effective in the conservative treatment of plantar fasciitis, we recommend the use of silicone insoles as a first line of treatment for persons with plantar fasciitis.

  3. Comparison of clinical marking and ultrasound-guided injection of Botulinum type A toxin into the masseter muscles for treating bruxism and its cosmetic effects.

    PubMed

    Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo

    2016-09-01

    Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.

  4. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    PubMed

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  5. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    PubMed

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  6. Evaluating the functional outcomes of ultrasound-guided botulinum toxin type A injections using the Euro-musculus approach for upper limb spasticity treatment in post-stroke patients; an observational study.

    PubMed

    Buyukavci, Raikan; Akturk, Semra; Ersoy, Yüksel

    2018-02-07

    Ultrasound-guided botulinum toxin type A injection is an effective treatment for spasticity. Euro-musculus spasticity approach is a new method for administering injections to the correct point of the correct muscle. The clinical outcomes of this practical approach is not yet available in the literature. The purpose of this study was to evaluate the effects on spasticity and the functional outcomes of ultrasound guided botulinum toxin type A injections via the Euro-musculus spasticity approach to treat upper limb spasticity in post-stroke patients. An observational study. Inpatient post-stroke patients. Twenty five post-stroke patients with post-stroke upper limb spasticity were recruited. The ultrasound-guided botulinum toxin type A injections were administered into the spastic target muscles using the Euro-musculus spasticity approach, and all of the patients were enrolled in rehabilitation programmes after the injections. This research included the innervation zone and injection site figures and ultrasound images of each muscle in the upper limb. The degree of spasticity was assessed via the Modified Ashworth Scale and the upper limb motor function via the Fugl Meyer Upper Extremity Scale at the baseline and 4 and 12 weeks after the botulinum toxin type A injection. Significant decreases in the Modified Ashworth Scale scores of the upper limb flexor muscle tone measured 4 and 12 weeks after the botulinum toxin type A injection were found when compared to the baseline scores (p<0.025). When compared with the baseline Fugl Meyer Upper Extremity subgroup scores, the sitting position, wrist and total scores at 4 and 12 weeks were significantly improved (p<0.025). However, only the Fugl Meyer Upper Extremity hand scores were significantly improved 12 weeks after the injection (p<0.025). Ultrasound-guided botulinum toxin type A injection via the Euro- musculus spasticity approach is a practical and effective method for administering injections to the correct point of

  7. Ultrasound image-guided therapy enhances antitumor effect of cisplatin.

    PubMed

    Sasaki, Noboru; Kudo, Nobuki; Nakamura, Kensuke; Lim, Sue Yee; Murakami, Masahiro; Kumara, W R Bandula; Tamura, Yu; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2014-01-01

    The aim of this study was to clarify whether ultrasound image-guided cisplatin delivery with an intratumor microbubble injection enhances the antitumor effect in a xenograft mouse model. Canine thyroid adenocarcinoma cells were used for all experiments. Before in vivo experiments, the cisplatin and microbubble concentration and ultrasound exposure time were optimized in vitro. For in vivo experiments, cells were implanted into the back of nude mice. Observed by a diagnostic ultrasound machine, a mixture of cisplatin and ultrasound contrast agent, Sonazoid, microbubbles was injected directly into tumors. The amount of injected cisplatin and microbubbles was 1 μg/tumor and 1.2 × 10(7) microbubbles/tumor, respectively, with a total injected volume of 20 μl. Using the same diagnostic machine, tumors were exposed to ultrasound for 15 s. The treatment was repeated four times. The combination of cisplatin, microbubbles, and ultrasound significantly delayed tumor growth as compared with no treatment (after 18 days, 157 ± 55 vs. 398 ± 49 mm(3), P = 0.049). Neither cisplatin alone nor the combination of cisplatin and ultrasound delayed tumor growth. The treatment did not decrease the body weight of mice. Ultrasound image-guided anticancer drug delivery may enhance the antitumor effects of drugs without obvious side effects.

  8. Ultrasound-guided versus fluoroscopy-guided sacroiliac joint intra-articular injections in the noninflammatory sacroiliac joint dysfunction: a prospective, randomized, single-blinded study.

    PubMed

    Jee, Haemi; Lee, Ji-Hae; Park, Ki Deok; Ahn, Jaeki; Park, Yongbum

    2014-02-01

    To compare the short-term effects and safety of ultrasound (US)-guided sacroiliac joint (SIJ) injections with fluoroscopy (FL)-guided SIJ injections in patients with noninflammatory SIJ dysfunction. Prospective, randomized controlled trial. University hospital. Patients (N=120) with noninflammatory sacroiliac arthritis were enrolled. All procedures were performed using an FL or US apparatus. Subjects were randomly assigned to either the FL or US group. Immediately after the SIJ injections, fluoroscopy was applied to verify the correct placement of the injected medication and intravascular injections. Treatment effects and functional improvement were compared at 2 and 12 weeks after the procedures. The verbal numeric pain scale and Oswestry Disability Index improved at 2 and 12 weeks after the injections without statistical significances between groups. Of 55 US-guided injections, 48 (87.3%) were successful and 7 (12.7%) were missed. The FL-guided SIJ approach exhibited a greater accuracy (98.2%) than the US-guided approach. Vascularization around the SIJ was seen in 34 of 55 patients. Among the 34 patients, 7 had vascularization inside the joint, 23 had vascularization around the joint, and 4 had vascularization both inside and around the joint. Three cases of intravascular injections occurred in the FL group. The US-guided approach may facilitate the identification and avoidance of the critical vessels around or within the SIJ. Function and pain relief significantly improved in both groups without significant differences between groups. The US-guided approach was shown to be as effective as the FL-guided approach in treatment effects. However, diagnostic application in the SIJ may be limited because of the significantly lower accuracy rate (87.3%). Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Pain reduction and improvement of function following ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid in hip osteoarthritis.

    PubMed

    Araújo, J P; Silva, L; Andrade, R; Paços, M; Moreira, H; Migueis, N; Pereira, R; Sarmento, A; Pereira, H; Loureiro, N; Espregueira-Mendes, J

    2016-01-01

    The scientific literature has shown positive results regarding intra-articular injections of hyaluronic acid in osteoarthritic joints. When injecting in the hip joint, the guidance of ultrasound can provide higher injection accuracy and repeatability. However, due to the methodological limitations in the current available literature, its recommendation in the current practice is still controversial. This study shows that ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid can improve pain, function and quality of life in patients with symptomatic and radiographic hip osteoarthritis. In addition, the administration of triamcinolone hexacetonide and hyaluronic acid to the hip joint in these patients can delay the need for interventional surgery.

  10. A new technical contribution for ultrasound-guided injections of sacro-iliac joints.

    PubMed

    Migliore, A; Bizzi, E; Massafra, U; Vacca, F; Martin-Martin, L S; Granata, M; Tormenta, S

    2010-05-01

    Sacroiliac joint (SIJ) represents a difficult location for local therapies, as intra-articular injections may be hard to execute, especially in particular conditions such as chronic inflammatory diseases. However, in selected patients, local therapies may be considered. Some recent studies demonstrated the feasibility of ultrasound (US)-guided injection of SIJ, but still a complete explanation and definition of the technique is needed. Seven patients, four males and 3 females, affected by mono or bilateral sacroiliitis entered the study. Each patient received 40 mg of acetonide triamcinolone for each SIJ, intra articular (IA) US-guided injection. The technical originality proposed in this study consists in the spinal needle insertion in the middle of the cranial long side of the linear transducer with an orientation of about 10 degrees, determining shorter needle insertion for reaching joint space and consequently probably granting lesser pain and traumatism for patients. A total of 22 injections was performed. The longer follow-up time obtained was 18 months in 3 patients. All patients reached at least a 6 month follow-up. All patients reported an amelioration in pain that lasted for at least 6 months. No systemic adverse events were reported or observed. Complete visualization of SIJ and of needle placement was performed by US imaging, while compound proper injection was also visualized by Color-Doppler US imaging. Actually, sacroiliac joint intraarticular injections are often performed under fluoroscopy or Computerized Tomography guidance. Such techniques present several limitations, especially for repeated injections, such as the use of ionizing radiations, the need of a contrast agent and the direct and indirect costs connected. US guidance in IA SIJ injections may represent an easily repeatable imaging technique for needle placement and a precious tool for detecting inflammatory activity of the joint.

  11. Application of a topical vapocoolant spray decreases pain at the site of initial intradermal anaesthetic injection during ultrasound-guided breast needle biopsy.

    PubMed

    Collado-Mesa, F; Net, J M; Arheart, K; Klevos, G A; Yepes, M M

    2015-09-01

    To assess whether the application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy decreases pain at the site of the initial injection. In this institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study, 50 women aged 49.1 ± 1.6 years (mean ± standard error) were recruited and provided written informed consent. Participants served as their own controls and were blinded as to whether a topical vapocoolant spray or a placebo was used immediately prior to the initial local anaesthetic injection at two separate biopsy sites. With the exception of the application of vapocoolant or placebo, the entire ultrasound-guided procedure was performed according to a routine protocol. Participants recorded pain at initial injection site on a visual analogue scale. General linear mixed models for repeated measures analysis of variance and a 0.05 significance level were used. Application of topical vapocoolant spray was shown to significantly decrease pain at the site of initial intradermal anaesthetic injection as compared to placebo (p<0.001). Treatment effect was independent of age of the subject, race/ethnicity, operator, type of biopsy device, and histopathology result. No complications from vapocoolant spray use were reported. Application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy significantly decreases pain at the site of the initial injection and could contribute to improve the patient's overall procedural experience. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. A randomized, double-blind, controlled study of ultrasound-guided corticosteroid injection into the joint of patients with inflammatory arthritis.

    PubMed

    Cunnington, Joanna; Marshall, Nicola; Hide, Geoff; Bracewell, Claire; Isaacs, John; Platt, Philip; Kane, David

    2010-07-01

    Most corticosteroid injections into the joint are guided by the clinical examination (CE), but up to 70% are inaccurately placed, which may contribute to an inadequate response. The aim of this study was to investigate whether ultrasound (US) guidance improves the accuracy and clinical outcome of joint injections as compared with CE guidance in patients with inflammatory arthritis. A total of 184 patients with inflammatory arthritis and an inflamed joint (shoulder, elbow, wrist, knee, or ankle) were randomized to receive either US-guided or CE-guided corticosteroid injections. Visual analog scales (VAS) for assessment of function, pain, and stiffness of the target joint, a modified Health Assessment Questionnaire, and the EuroQol 5-domain questionnaire were obtained at baseline and at 2 weeks and 6 weeks postinjection. The erythrocyte sedimentation rate and C-reactive protein level were measured at baseline and 2 weeks. Contrast injected with the steroid was used to assess the accuracy of the joint injection. One-third of CE-guided injections were inaccurate. US-guided injections performed by a trainee rheumatologist were more accurate than the CE-guided injections performed by more senior rheumatologists (83% versus 66%; P = 0.010). There was no significant difference in clinical outcome between the group receiving US-guided injections and the group receiving CE-guided injections. Accurate injections led to greater improvement in joint function, as determined by VAS scores, at 6 weeks, as compared with inaccurate injections (30.6 mm versus 21.2 mm; P = 0.030). Clinicians who used US guidance reliably assessed the accuracy of joint injection (P < 0.001), whereas those who used CE guidance did not (P = 0.29). US guidance significantly improves the accuracy of joint injection, allowing a trainee to rapidly achieve higher accuracy than more experienced rheumatologists. US guidance did not improve the short-term outcome of joint injection.

  13. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    PubMed

    Spiliopoulos, S; Katsanos, K; Diamantopoulos, A; Karnabatidis, D; Siablis, D

    2011-05-01

    To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Between January 2009 and 2010, 200 patients (161 men, mean age 63±12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6±1.6 versus 4.6±1.9, p<0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16±2.7 versus 19±0.8ml, p<0.001).Total vascular access time was similar in both groups (4.4±1.3 versus 4.5±1.3min). Overall complications included two small groin haematomas in each group. Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Ultrasound-Guided Thrombin Injection Is a Safe and Effective Treatment for Femoral Artery Pseudoaneurysm in the Morbidly Obese.

    PubMed

    Yoo, Taehwan; Starr, Jean E; Go, Michael R; Vaccaro, Patrick S; Satiani, Bhagwan; Haurani, Mounir J

    2017-08-01

    Ultrasound-guided thrombin injection (UGTI) is a well-established practice for the treatment of femoral artery pseudoaneurysm. This procedure is highly successful but dependent on appropriate pseudoaneurysm anatomy and adequate ultrasound visualization. Morbid obesity can present a significant technical challenge due to increased groin adiposity, resulting in poor visualization of critical structures needed to safely perform the procedure. We aim to evaluate the safety and efficacy of UGTI to treat femoral artery pseudoaneurysm in the morbidly obese. This is a retrospective cohort study in which all patients who underwent UGTI at The Ohio State University Ross Heart Hospital from 2009 to 2014 were analyzed for patient characteristics and stratified by body mass index (BMI). Patients with BMI ≥ 35 were considered morbidly obese and were compared to patients with a BMI < 35. Outcome was failed treatment resulting in residual pseudoaneurysm. Our cohort consisted of 54 patients who underwent thrombin injection. There were 41 nonmorbidly obese and 13 morbidly obese patients. Mean age was 64.5 years. The cohort was 44.4% male. There were 6 failures, of which 1 underwent successful repeat injection and 5 underwent open surgical repair. There was no statistically significant difference in failure between nonmorbidly obese and morbidly obese patients (9.8% vs 15.4%, P = .45). There were no embolic/thrombotic complications. Ultrasound-guided thrombin injection is a safe and effective therapy in the morbidly obese for the treatment of femoral artery pseudoaneurysm. In the hands of experienced sonographers and surgeons with adequate visualization of the pseudoaneurysm sac, UGTI should remain a standard therapy in the morbidly obese.

  15. Successful Treatment of Abdominal Cutaneous Entrapment Syndrome Using Ultrasound Guided Injection

    PubMed Central

    Hong, Myong Joo; Seo, Dong Hyuk

    2013-01-01

    There are various origins for chronic abdominal pain. About 10-30% of patients with chronic abdominal pain have abdominal wall pain. Unfortunately, abdominal wall pain is not thought to be the first origin of chronic abdominal pain; therefore, patients usually undergo extensive examinations, including diagnostic laparoscopic surgery. Entrapment of abdominal cutaneous nerves at the muscular foramen of the rectus abdominis is a rare cause of abdominal wall pain. If abdominal wall pain is considered in earlier stage of chronic abdominal pain, unnecessary invasive procedures are not required and patients will reach symptom free condition as soon as the diagnosis is made. Here, we report a case of successful treatment of a patient with abdominal cutaneous nerve entrapment syndrome by ultrasound guided injection therapy. PMID:23862004

  16. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    PubMed Central

    Allam, Abdallah El-Sayed; Khalil, Adham Aboul Fotouh; Eltawab, Basma Aly; Wu, Wei-Ting

    2018-01-01

    Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves. PMID:29808105

  17. Retrospective Analysis of the Accuracy of Ultrasound-Guided Magnetic Resonance Arthrogram Injections of the Hip in the Office Setting.

    PubMed

    Jernick, Michael; Walker Gallego, Edward; Nuzzo, Michael

    2017-12-01

    Ultrasound (US)-guided intra-articular hip injections have been proposed in the literature to be accurate, reliable, and safe alternatives to fluoroscopy-guided injections. To evaluate the accuracy of US-guided magnetic resonance (MR) arthrogram injections of the hip performed in the office setting by a single orthopaedic surgeon and elucidate the potential effects that patient age, sex, and body mass index (BMI) have on contrast placement. Case series; Level of evidence, 4. From a review of the senior author's office database, 89 patients (101 hips) who had US-guided MR arthrogram injections performed between December 2014 and June 2016 were identified. Official radiology reports were evaluated to determine whether extra-articular contrast was noted. Patient variables, including BMI, age, and sex, were evaluated between patients who had inappropriately placed contrast and those who did not. Of the 101 hip injections, there were 6 cases that demonstrated inadequate contrast placement within the joint, likely secondary to extravasation or incorrect placement; however, an MR arthrogram was adequately interpreted in all cases. There were no significant differences noted between those with appropriate versus inappropriate contrast placement when evaluating BMI ( P = .57), age ( P = .33), or sex ( P = .67), and neither group had an adverse event. US-guided injections are safe and accurate alternatives to fluoroscopy-guided injections in the office setting, with 94% accuracy. Furthermore, BMI, age, and sex did not play a statistically significant role among patients with inappropriately placed contrast.

  18. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma.

    PubMed

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side ( P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  19. Comparative Effectiveness of Radial Extracorporeal Shockwave Therapy and Ultrasound-Guided Local Corticosteroid Injection Treatment for Plantar Fasciitis.

    PubMed

    Hocaoglu, Sehriban; Vurdem, Umit Erkan; Cebicci, Mehtap Aykac; Sutbeyaz, Serap Tomruk; Guldeste, Zuhal; Yunsuroglu, Serap Gurek

    2017-05-01

    We compared the long-term clinical and ultrasonographic effects of radial extracorporeal shockwave therapy (rESWT) versus ultrasound-guided corticosteroid injection treatment in patients with plantar fasciitis unresponsive to conservative therapy. Seventy-two patients with unilateral plantar fasciitis were randomized to receive either rESWT (three times once per week) (n = 36) or corticosteroid treatment (a single 1-mL dose of betamethasone sodium plus 0.5 mL of prilocaine under ultrasound guidance by injection into the plantar fascia) (n = 36). The primary outcome measures were visual analog scale (VAS) and Foot Function Index (FFI) scores. Secondary outcome measures included the heel tenderness index (HTI) score and plantar fascia thickness (PFT) as obtained by ultrasound examination. All of the assessments were performed at baseline and 1, 3, and 6 months after treatment. Significant improvements were observed in the rESWT group in VAS, HTI, and FFI scores and PFT at the end of treatment and were maintained during follow-up. Posttreatment improvements in VAS, HTI, and FFI scores and PFT were also seen in the corticosteroid group but were not maintained for VAS and FFI scores after the completion of therapy and were lost at 1 and 6 months, respectively. No serious treatment-related complications occurred. Both rESWT and corticosteroid injection therapy are effective modalities for treatment of chronic plantar fasciitis. However, rESWT seems to be superior to corticosteroid injection therapy due to its longer duration of action.

  20. Palpation Versus Ultrasound-Guided Acromioclavicular Joint Intra-articular Corticosteroid Injections: A Retrospective Comparative Clinical Study.

    PubMed

    Park, Ki Deok; Kim, Tai Kon; Lee, Jihae; Lee, Woo Yong; Ahn, Jae Ki; Park, Yongbum

    2015-01-01

    Primary osteoarthritis (OA) is the most common cause of pain arising from the acromioclavicular (AC) joint. The true incidence is unknown because of differences in the criteria used to define arthritis in various studies. The proper diagnosis of AC joint OA requires a thorough physical examination, radiographic findings, and a diagnostic local anesthetic injection. The goal of this study was to assess the effects and safety of ultrasound (US) versus palpation-guided acromioclavicular (AC) joint intra-articular (IA) corticosteroid injection for patients with osteoarthritis (OA) of the AC joint. Retrospective, compared clinical study. University hospital outpatient pain clinic. We retrospectively reviewed the charts of patients with AC joint degenerative OA who had undergone US or palpation-guided AC joint IA corticosteroid injection between January 2012 and December 2013 at our outpatient clinic. One hundred consecutive patients identified from chart review met inclusion criteria. Patients (N = 50) in US guide AC joint IA steroid injection group were administered a mixture of 0.5% lidocaine (1 mL) with triamcinolone (20 mg/mL; 0.5 mL) and radiographic contrast material (0.5 mL) and patients (N = 50) in palpation-guided AC joint IA steroid injection group were administered a mixture of 0.5% lidocaine (1 mL) with triamcinolone (20 mg/mL; 0.5 mL) and 0.5 mL of radiographic contrast material. Results were measured using the Shoulder Pain and Disability Index (SPADI), Verbal Numeric pain Scale (VNS) at rest (VNSar), under local pressure (VNSlp) ,and the arm adduction test (VNSaat) at the joint space area before injections and at one, 3, and 6 months after the injections. Successful treatment occurred when patients obtained significant pain relief (as measured by > 50% improvement in the VNS score and 20 point improvement in the SPADI) at one, 3, and 6 months after the injections. Univariable analysis was performed to evaluate the relationship between possible outcome

  1. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    PubMed Central

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment. PMID:28900553

  2. Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.

    PubMed

    Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A

    2010-02-01

    Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.

  3. Palpation- and ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    da Cunha, Anderson F; Strain, George M; Rademacher, Nathalie; Schnellbacher, Rodney; Tully, Thomas N

    2013-01-01

    To compare palpation-guided with ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots. Prospective randomized experimental trial. Eighteen adult Hispaniolan Amazon parrots (Amazona ventralis) weighing 252-295 g. After induction of anesthesia with isoflurane, parrots received an injection of lidocaine (2 mg kg(-1)) in a total volume of 0.3 mL at the axillary region. The birds were randomly assigned to equal groups using either palpation or ultrasound as a guide for the brachial plexus block. Nerve evoked muscle potentials (NEMP) were used to monitor effectiveness of brachial plexus block. The palpation-guided group received the local anesthetic at the space between the pectoral muscle, triceps, and supracoracoideus aticimus muscle, at the insertion of the tendons of the caudal coracobrachial muscle, and the caudal scapulohumeral muscle. For the ultrasound-guided group, the brachial plexus and the adjacent vessels were located with B-mode ultrasonography using a 7-15 MHz linear probe. After location, an 8-5 MHz convex transducer was used to guide injections. General anesthesia was discontinued 20 minutes after lidocaine injection and the birds recovered in a padded cage. Both techniques decreased the amplitude of NEMP. Statistically significant differences in NEMP amplitudes, were observed within the ultrasound-guided group at 5, 10, 15, and 20 minutes after injection and within the palpation-guided group at 10, 15, and 20 minutes after injection. There was no statistically significant difference between the two groups. No effect on motor function, muscle relaxation or wing droop was observed after brachial plexus block. The onset of the brachial plexus block tended to be faster when ultrasonography was used. Brachial plexus injection can be performed in Hispaniolan Amazon parrots and nerve evoked muscle potentials were useful to monitor the effects on nerve conduction in this avian species. Neither technique produced an effective block at the

  4. Mechanical Metatarsalgia as a Risk Factor for Relapse of Morton's Neuroma After Ultrasound-Guided Alcohol Injection.

    PubMed

    Lorenzon, Paolo; Rettore, Carlo

    2018-05-17

    Although many treatment modalities are available for Morton's neuroma, the injection of the neuroma with alcohol has gained popularity. However, recently, some investigators have observed a progressive deterioration in pain scores for patients initially pain free after the treatment. The purpose of the present retrospective comparative study was to determine whether mechanical metatarsalgia is related to symptom recurrence. We included 104 consecutive cases of ultrasound-guided alcohol injection for Morton's neuroma in 92 patients. Of these 104 cases, 51 were in group A (49%; Morton's neuroma) and 53 in group B (51%; Morton's neuroma associated with mechanical metatarsalgia). We evaluated each patient using a visual analog scale and American Orthopaedic Foot and Ankle Society forefoot scale, and Johnson satisfaction scale, with a mean follow-up period of 24 (range 12 to 39) months. Concomitant functional and mechanical disorders have been identified and treated with orthopedic inserts. The present study compared the clinical results and recurrence of symptoms in patients with isolated Morton's disease or Morton's disease associated with mechanical metatarsalgia. Of the 104 cases, the patients for 93 cases (89%) were completely satisfied or satisfied with minor reservations. No major complications developed. Symptoms recurred in 6 patients (6%), in whom neuroma was associated with mechanical disorders (p = .0269). Ultrasound-guided alcohol injection of Morton's neuroma is a relatively safe and well-tolerated treatment. Symptom recurrence is often associated with mechanical metatarsalgia. The treatment of the concomitant anatomical and functional disorders that target the genesis of the neuroma has an important role in the prevention of recurrence of this pathology. Copyright © 2018 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  6. Comparison between ultrasound-guided compression and para-aneurysmal saline injection in the treatment of postcatheterization femoral artery pseudoaneurysms.

    PubMed

    ElMahdy, Mahmoud Farouk; Kassem, Hussien Heshmat; Ewis, Essam Baligh; Mahdy, Soliman Gharieb

    2014-03-01

    Management of postcatheterization femoral artery pseudoaneurysm (FAP) is problematic. Ultrasound-guided compression (UGC) is painful and cumbersome. Thrombin injection is costly and may cause thromboembolism. Ultrasound-guided para-aneurysmal saline injection (PASI) has been described but was never compared against other treatment methods of FAP. We aimed at comparing the success rate and complications of PASI versus UGC. We randomly assigned 80 patients with postcatheterization FAPs to either UGC (40 patients) or PASI (40 patients). We compared the 2 procedures regarding successful obliteration of the FAP, incidence of vasovagal attacks, procedure time, discontinuation of antiplatelet and/or anticoagulants, and the Doppler waveform in the ipsilateral pedal arteries at the end of the procedure. There was no significant difference between patients in both groups regarding clinical and vascular duplex data. The mean durations of UGC and PASI procedures were 58.14 ± 28.45 and 30.33 ± 8.56 minutes, respectively (p = 0.045). Vasovagal attacks were reported in 10 (25%) and 2 patients (5%) treated with UGC and PASI, respectively (p = 0.05). All patients in both groups had triphasic Doppler waveform in the infrapopliteal arteries before and after the procedure. The primary and final success rates were 75%, 92.5%, 87.5%, and 95% for UGC and PASI, respectively (p = 0.43). In successfully treated patients, there was no reperfusion of the FAP in the follow-up studies (days 1 and 7) in both groups. In conclusion, ultrasound-guided PASI is an effective method for the treatment of FAP. Compared with UGC, PASI is faster, less likely to cause vasovagal reactions, and can be more convenient to patients and physicians. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Feasibility of ultrasound-guided epidural access at the lumbo-sacral space in dogs.

    PubMed

    Liotta, Annalisa; Busoni, Valeria; Carrozzo, Maria Valentina; Sandersen, Charlotte; Gabriel, Annick; Bolen, Géraldine

    2015-01-01

    Epidural injections are commonly performed blindly in veterinary medicine. The aims of this study were to describe the lumbosacral ultrasonographic anatomy and to assess the feasibility of an ultrasound-guided epidural injection technique in dogs. A cross sectional anatomic atlas of the lumbosacral region and ex vivo ultrasound images were obtained in two cadavers to describe the ultrasound anatomy and to identify the landmarks. Sixteen normal weight canine cadavers were used to establish two variations of the technique for direct ultrasound-guided injection, using spinal needles or epidural catheters. The technique was finally performed in two normal weight cadavers, in two overweight cadavers and in five live dogs with radiographic abnormalities resulting of the lumbosacral spine. Contrast medium was injected and CT was used to assess the success of the injection. The anatomic landmarks to carry out the procedure were the seventh lumbar vertebra, the iliac wings, and the first sacral vertebra. The target for directing the needle was the trapezoid-shaped echogenic zone between the contiguous articular facets of the lumbosacral vertebral canal visualized in a parasagittal plane. The spinal needle or epidural catheter was inserted in a 45° craniodorsal-caudoventral direction through the subcutaneous tissue and the interarcuate ligament until reaching the epidural space. CT examination confirmed the presence of contrast medium in the epidural space in 25/25 dogs, although a variable contamination of the subarachnoid space was also noted. Findings indicated that this ultrasound-guided epidural injection technique is feasible for normal weight and overweight dogs, with and without radiographic abnormalities of the spine. © 2014 American College of Veterinary Radiology.

  8. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures.

    PubMed

    Barile, Antonio; La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-09-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases.

  9. Free-hand ultrasound guidance permits safe and efficient minimally invasive intrathymic injections in both young and aged mice.

    PubMed

    Tuckett, Andrea Z; Zakrzewski, Johannes L; Li, Duan; van den Brink, Marcel R M; Thornton, Raymond H

    2015-04-01

    The goal of this study was to evaluate whether use of an aseptic free-hand approach to ultrasound-guided injection facilitates injection into the thymic gland in mice. We used this interventional radiology technique in young, aged and immunodeficient mice and found that the thymus was visible in all cases. The mean injection period was 8 seconds in young mice and 19 seconds in aged or immunodeficient mice. Injection accuracy was confirmed by intrathymic location of an injected dye or by in vivo bioluminescence imaging of injected luciferase-expressing cells. Accurate intrathymic injection was confirmed in 97% of cases. No major complications were observed. We conclude that an aseptic freehand technique for ultrasound-guided intrathymic injection is safe and accurate and reduces the time required for intrathymic injections. This method facilitates large-scale experiments and injection of individual thymic lobes and is clinically relevant. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  11. Efficacy and Safety of Single Botulinum Toxin Type A (Botox®) Injection for Relief of Upper Trapezius Myofascial Trigger Point: A Randomized, Double-Blind, Placebo-Controlled Study.

    PubMed

    Kwanchuay, Photsawee; Petchnumsin, Thavatchai; Yiemsiri, Pichet; Pasuk, Nakkamol; Srikanok, Wannarat; Hathaiareerug, Chanasak

    2015-12-01

    Botulinum toxin injection has been applied for pain relief in various chronic pain syndromes. Recently, systematic review studies reported inconclusive effects of Botulinum toxin in myofascial pain management. The present study aimed to demonstrate the efficacy and safety of Botulinum toxin type A (BTxA) (Botox®) injection for pain reduction in myofascial trigger point (MTrP) of the upper trapezius muscle. Thirty-three patients with 48 MTrP on the upper trapezius muscles over three months with moderate to severe pain intensity diagnosed at physical medicine and rehabilitation outpatient department were recruited between December 2011 and March 2012. Eligible patients were blinded and randomly injected with single 0.2 ml (20 IU) of BTxA for 24 MTrP and 0.2 ml of 0.9% NaCl solution for 24 MTrP at the most tender trigger point on the upper trapezius muscle. All patients were advised for stretching exercise and ergonomic adaptation throughout the study. At 3- and 6-week after injections, visual analogue scale (VAS), the pressure pain threshold (PPT), and reported adverse effects were measured. Both BTxA and control groups demonstrated statistically significant differences in VAS reduction and increased PPT after 3 weeks and 6 weeks compared with before treatment. There were no statistically significant differences in VAS reduction from baseline between the two groups at 3- and 6-week after treatment. A statistically significant difference in improvement of PPT from baseline and 6-week after BTxA injection compared with 0.9% NaCl group was shown (1.0 ± 0.9 and 0.5 ± 0.7, p = 0.036). There was mild degree side-effects that spontaneous resolved within one week in both groups without significant difference in percentage. No severe adverse effects were reported during the study. The efficacy in VAS reduction of a single 20 IU of Botulinum toxin type A (Botox®) injection was not different from 0.9% NaCl for myofascial trigger point at the upper trapezius muscle. However

  12. Targeted Ultrasound-Guided Perineural Hydrodissection of the Sciatic Nerve for the Treatment of Piriformis Syndrome.

    PubMed

    Burke, Christopher J; Walter, William R; Adler, Ronald S

    2018-05-01

    Piriformis syndrome is a common cause of lumbar, gluteal, and thigh pain, frequently associated with sciatic nerve symptoms. Potential etiologies include muscle injury or chronic muscle stretching associated with gait disturbances. There is a common pathological end pathway involving hypertrophy, spasm, contracture, inflammation, and scarring of the piriformis muscle, leading to impingement of the sciatic nerve. Ultrasound-guided piriformis injections are frequently used in the treatment of these pain syndromes, with most of the published literature describing injection of the muscle. We describe a safe, effective ultrasound-guided injection technique for the treatment of piriformis syndrome using targeted sciatic perineural hydrodissection followed by therapeutic corticosteroid injection.

  13. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures

    PubMed Central

    La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-01-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases. PMID:27302491

  14. Feasibility of ultrasound-guided sacroiliac joint injection considering sonoanatomic landmarks at two different levels in cadavers and patients.

    PubMed

    Klauser, Andrea; De Zordo, Tobias; Feuchtner, Gudrun; Sögner, Peter; Schirmer, Michael; Gruber, Johann; Sepp, Norbert; Moriggl, Bernhard

    2008-11-15

    Sacroiliitis is often caused by rheumatic diseases, and besides other therapeutic options, treatment consists of intraarticular injection of corticosteroids. The purpose of this study was to assess the feasibility of ultrasound (US)-guided sacroiliac joint (SI joint) injection at 2 different puncture levels in cadavers and patients when defined sonoanatomic landmarks were considered. After defining sonoanatomic landmarks, US-guided needle insertion was performed in 10 human cadavers (20 SI joints) at 2 different puncture sites. Upper level was defined at the level of the posterior sacral foramen 1 and lower level at the level of the posterior sacral foramen 2. In 10 patients with unilateral sacroiliitis, injection at the most feasible level was attempted. Computed tomography confirmed correct intraarticular needle placement in cadavers by showing the tip of the needle in the joint and intraarticular diffusion of contrast media in 16 (80%) of 20 SI joints (upper level 7 [70%] of 10; lower level 9 [90%] of 10). In all 4 cases in which needle insertion failed, intraarticular SI joint injection at the other level was successful. In patients, 100% of US-guided injections were successful (8 lower level, 2 upper level), with a mean pain relief of 8.6 after 3 months. US guidance of needle insertion into SI joints was feasible at both levels when defined sonoanatomic landmarks were used. If SI joint alterations do not allow for direct visualization of the dorsal joint space of the lower level, which is easier to access, the upper level might offer an appropriate alternative.

  15. Ultrasound-Guided Injection of Botulinum Toxin Type A for Piriformis Muscle Syndrome: A Case Report and Review of the Literature

    PubMed Central

    Santamato, Andrea; Micello, Maria Francesca; Valeno, Giovanni; Beatrice, Raffaele; Cinone, Nicoletta; Baricich, Alessio; Picelli, Alessandro; Panza, Francesco; Logroscino, Giancarlo; Fiore, Pietro; Ranieri, Maurizio

    2015-01-01

    Piriformis muscle syndrome (PMS) is caused by prolonged or excessive contraction of the piriformis muscle associated with pain in the buttocks, hips, and lower limbs because of the close proximity to the sciatic nerve. Botulinum toxin type A (BoNT-A) reduces muscle hypertonia as well as muscle contracture and pain inhibiting substance P release and other inflammatory factors. BoNT-A injection technique is important considering the difficult access of the needle for deep location, the small size of the muscle, and the proximity to neurovascular structures. Ultrasound guidance is easy to use and painless and several studies describe its use during BoNT-A administration in PMS. In the present review article, we briefly updated current knowledge regarding the BoNT therapy of PMS, describing also a case report in which this syndrome was treated with an ultrasound-guided injection of incobotulinumtoxin A. Pain reduction with an increase of hip articular range of motion in this patient with PMS confirmed the effectiveness of BoNT-A injection for the management of this syndrome. PMID:26266421

  16. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System.

    PubMed

    Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas

    2017-02-01

    Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.

  17. Ultrasound-guided injection for MR arthrography of the hip: comparison of two different techniques.

    PubMed

    Kantarci, Fatih; Ozbayrak, Mustafa; Gulsen, Fatih; Gencturk, Mert; Botanlioglu, Huseyin; Mihmanli, Ismail

    2013-01-01

    The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for MR arthrography of the hip. Fifty-nine consecutive patients (21 men, 38 women) referred for MR arthrographies of the hip were prospectively included in the study. Three patients underwent bilateral MR arthrography. The two injection techniques were quantitatively and qualitatively compared. Quantitative analysis was performed by the comparison of injected contrast material volume into the hip joint. Qualitative analysis was performed with regard to extraarticular leakage of contrast material into the soft tissues. Extraarticular leakage of contrast material was graded as none, minimal, moderate, or severe according to the MR images. Each patient rated discomfort after the procedure using a visual analogue scale (VAS). The injected contrast material volume was less in femoral head puncture technique (mean 8.9 ± 3.4 ml) when compared to femoral neck puncture technique (mean 11.2 ± 2.9 ml) (p < 0.05). The chi-squared test showed significantly more contrast leakage by femoral head puncture technique (p < 0.05). Statistical analysis showed no difference between the head and neck puncture groups in terms of feeling of pain (p = 0.744) or in the body mass index (p = 0.658) of the patients. The femoral neck injection technique provides high intraarticular contrast volume and produces less extraarticular contrast leakage than the femoral head injection technique when US guidance is used for MR arthrography of the hip.

  18. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    PubMed

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Free-hand ultrasound guidance permits safe and efficient minimally invasive intrathymic injections in both young and aged mice

    PubMed Central

    Tuckett, Andrea Z.; Zakrzewski, Johannes L.; Li, Duan; van den Brink, Marcel R.M.; Thornton, Raymond H.

    2014-01-01

    The goal of this study was to evaluate whether using an aseptic free-hand approach for ultrasound-guided injection facilitates injection into the thymic gland in mice. We used this interventional radiology technique in young, aged, and immunodeficient mice and found that the thymus was visible in all cases. The mean injection period was 8 s in young mice and 19 s in aged or immunodeficient mice. Injection accuracy was confirmed by intrathymic location of an injected dye, or by in vivo bioluminescence imaging of injected luciferase-expressing cells. Accurate intrathymic injection was confirmed in 97% of cases. No major complications were observed. We conclude that an aseptic free-hand technique for ultrasound-guided intrathymic injection is safe, accurate, and reduces the time required for intrathymic injections. This method facilitates large-scale experiments, injection of individual thymic lobes, and is clinically relevant. PMID:25701534

  20. Perforator-Guided Drug Injection in the Treatment of Abdominal Wall Pain.

    PubMed

    Weum, Sven; de Weerd, Louis

    2016-07-01

    Pain from the abdominal wall can be caused by nerve entrapment, a condition called abdominal cutaneous nerve entrapment syndrome (ACNES). As an alternative to surgery, ACNES may be treated with injection of local anesthetics, corticosteroids, or botulinum toxin at the point of maximal pain. The point of maximal pain was marked on the abdominal skin. Using color Doppler ultrasound, the corresponding exit point of perforating blood vessels through the anterior fascia of the rectus abdominis muscle was identified. Ultrasound-guided injection of botulinum toxin in close proximity to the perforator's exit point was performed below and above the muscle fascia. The technique was used from 2008 to 2014 on 15 patients in 46 sessions with a total of 128 injections without complications. The injection technique provided safe and accurate administration of the drug in proximity to the affected cutaneous nerves. The effect of botulinum toxin on ACNES is beyond the scope of this article. Perforator-guided injection enables precise drug administration at the location of nerve entrapment in ACNES in contrast to blind injections. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  2. MR-guided Focused Ultrasound for Uterine Fibroids

    MedlinePlus

    ... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...

  3. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with

  4. Ultrasound-guided retro-calcaneal bursa corticosteroid injection for refractory Achilles tendinitis in patients with seronegative spondyloarthropathy: efficacy and follow-up study.

    PubMed

    Srivastava, Puja; Aggarwal, Amita

    2016-06-01

    Ultrasound (US)-guided corticosteroid injection has been shown to be safe and effective for varied causes of plantar fasciitis; however, its use for Achilles tendinitis is controversial. We studied the efficacy and changes in US findings at Achilles enthesitis after corticosteroid injection in patients with spondyloarthropathy (SpA). Patients with SpA with symptomatic Achilles enthesitis, refractory to 6 weeks of full-dose NSAIDs, were offered US-guided local corticosteroid injection. Injected entheses were examined by US (both B mode and power Doppler) at baseline and 6 weeks after injection. Standard OMERACT definitions were used to define enthesitis. Achilles tendon thickness >5.29 mm, 2 cm proximal to insertion in long axis, was considered thickened. Twenty-seven symptomatic Achilles tendons (in 18 patients) were injected with 20 mg methylprednisolone under US guidance baseline, and 6-week follow-up US features were compared. All patients reported improvement in pain (VAS) in the affected tendon after injection (p < 0.0001). Simultaneously, improvement in local inflammatory changes were noted, in the form of significant reduction in tendon thickness (p < 0.0001), vascularity (p < 0.0001), peritendinous oedema (p = 0.001), bursitis and bursal vascularity (p < 0.001 and < 0.0001, respectively). There was no change in bone erosions and enthesophyte. None of the patients had tendon rupture or other injection-related complications at 6 weeks of follow-up. US-guided local corticosteroid injection is an effective and safe modality for refractory Achilles enthesitis in patients with SpA and leads to reversion of acute changes at entheseal site.

  5. Ultrasound Imaging and Guided Injection for the Lateral and Posterior Hip.

    PubMed

    Chang, Ke-Vin; Wu, Wei-Ting; Lew, Henry L; Özçakar, Levent

    2018-04-01

    Ultrasound has emerged as one of the most utilized tools to diagnose musculoskeletal disorders and to assist in interventions. Traditionally, sonographic examination of the hip joint has been challenging because most of the major structures are deeply situated, thus requiring the use of curvilinear transducer for better penetrance. The posterior lateral hip is a frequent area for musculoskeletal pain and nerve entrapments. Common disorders include greater trochanteric pain syndrome, gluteus medius tendinopathy, piriformis syndrome, pudendal neuralgia, and proximal hamstring tendinopathy. The present review article aims to delineate sonoanatomy of the posterior lateral hip and to exemplify several common ultrasound guided procedures at the greater trochanteric, gluteal, and ischial tuberosity regions.

  6. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  7. Ultrasound-guided microinjection into the mouse forebrain in utero at E9.5.

    PubMed

    Pierfelice, Tarran J; Gaiano, Nicholas

    2010-11-13

    In utero survival surgery in mice permits the molecular manipulation of gene expression during development. However, because the uterine wall is opaque during early embryogenesis, the ability to target specific parts of the embryo for microinjection is greatly limited. Fortunately, high-frequency ultrasound imaging permits the generation of images that can be used in real time to guide a microinjection needle into the embryonic region of interest. Here we describe the use of such imaging to guide the injection of retroviral vectors into the ventricular system of the mouse forebrain at embryonic day (E) 9.5. This method uses a laparotomy to permit access to the uterine horns, and a specially designed plate that permits host embryos to be bathed in saline while they are imaged and injected. Successful surgeries often result in most or all of the injected embryos surviving to any subsequent time point of interest (embryonically or postnatally). The principles described here can be used with slight modifications to perform injections into the amnionic fluid of E8.5 embryos (thereby permitting infection along the anterior posterior extent of the neural tube, which has not yet closed), or into the ventricular system of the brain at E10.5/11.5. Furthermore, at mid-neurogenic ages (~E13.5), ultrasound imaging can be used direct injection into specific brain regions for viral infection or cell transplantation. The use of ultrasound imaging to guide in utero injections in mice is a very powerful technique that permits the molecular and cellular manipulation of mouse embryos in ways that would otherwise be exceptionally difficult if not impossible.

  8. Comparison of transcutaneous contrast-enhanced ultrasound-guided injected hemostatic agents with traditional surgery treatment for liver, spleen and kidney trauma: a retrospective study.

    PubMed

    Wang, Dong; Lv, Faqin; Luo, Yukun; An, Lichun; Li, Junlai; Xie, Xia; Tian, Jiangke; Zhao, Weiyan; Tang, Jie

    2012-10-01

    There is lack of studies on the effectiveness of transcutaneous contrast-enhanced ultrasound-guided injections of hemostatic agents for liver. spleen and kidney trauma. We compared treatment by hemostatic agents to surgical treatment in a retrospective interventional human study. The study enrolled a total of 135 subjects from emergency unit of the Chinese People's Liberation Army General Hospital in Beijing. Within the cohort, 62 patients received contrast enhanced ultrasound-guided injection of hemostatic agents and the rest received surgical treatments. The injury severity score was lower in the hemostatic agent treatment group than surgical treatment group (p<0.05), but Glasgow coma scale scores did not reach statistical significance. The patients in the surgical treatment group had significantly higher hospital fees than those in the hemostatic treatment group (p<0.05), although the length of hospitalization did not significantly differ between two groups. Safety outcome variables pre- and post-treatment remained within normal limits in both groups. Hemostatic agents were more cost-effective than surgery to treat patients with liver, spleen and kidney trauma. However, given the limited sample size, subsequent studies drawing upon larger populations from multiple medical centers are necessary for follow-up.

  9. A comparison of the VHI, VHI-10, and V-RQOL for measuring the effect of botox therapy in adductor spasmodic dysphonia.

    PubMed

    Morzaria, Sanjay; Damrose, Edward J

    2012-05-01

    Although disease-specific quality-of-life (QOL) instruments are an invaluable outcome measure in spasmodic dysphonia, there is no consensus on which QOL instrument should be used. To determine the responsiveness of the Voice Handicap Index (VHI), Voice Handicap Index-10 (VHI-10), and Voice-Related Quality of Life (V-RQOL) to the treatment effect of botulinum toxin (Botox) in adductor spasmodic dysphonia (ADSD). Stanford University Voice and Swallowing Center. Prospective case series (level of evidence=4). Consecutive ADSD patients with a stable Botox dose-response relationship were recruited prospectively. VHI, VHI-10, and V-RQOL scores were obtained pretreatment and during the middle third of the posttreatment injection cycle. Thrity-seven patients completed the follow-up. The average total Botox dose was 0.88 units. The average follow-up time after injection was 7.84 weeks. The pretreatment QOL scores reflected the burden of the disease. All the three instruments were highly correlated in subscale and total scores. After treatment, all three instruments showed significant improvement. The VHI, VHI-10, and V-RQOL all reflected the morbidity associated with ADSD and were significantly responsive to the effect of Botox therapy. The choice of instrument should be based on physician preference. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  10. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection.

    PubMed

    Gubler, Christoph; Bauerfeind, Peter

    2014-09-01

    Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy of all patients with gastric varices. Application was controlled by fluoroscopy to immediately detect any glue embolization. Only perforating veins located within the gastric wall were treated. In the follow up, we repeated this treatment until varices were eradicated. Utmost patients (36 of 40) were treated during or within 24 h of active bleeding. About 32.5% of patients were treated while visible bleeding. Histoacryl injection was always technically successful and only two patients suffered a minor complication. Acute bleeding was stopped in all patients. About 15% (6 of 40) of patients needed an alternative rescue treatment in the longer course. Three patients got a transjugular portosystemic shunt and another three underwent an orthotopic liver transplantation. Mean long-term survival of 60 months was excellent. Active bleeding of gastric varices can be treated successfully without the necessity of gastric rinsing with EUS-guided injection of Histoacryl.

  11. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    PubMed

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  12. Successful treatment of athletic pubalgia in a lacrosse player with ultrasound-guided needle tenotomy and platelet-rich plasma injection: a case report.

    PubMed

    Scholten, Paul M; Massimi, Stephen; Dahmen, Nick; Diamond, Joanne; Wyss, James

    2015-01-01

    Athletic pubalgia is a syndrome of persistent groin pain due to chronic repetitive trauma or stress involving the pelvic joints and many musculotendinous structures that cross the anterior pelvis. As a result, the differential diagnosis can be complex, but insertional tendinopathies are the most common. This case report describes a novel approach to the treatment of distal rectus abdominis tendinopathies with ultrasound-guided needle tenotomy and platelet-rich plasma (PRP) injection. After injection, the patient returned to pain-free play at his previous level of intensity. This suggests that PRP may be a useful treatment for this diagnosis. Copyright © 2015. Published by Elsevier Inc.

  13. Ultrasound-Guided Intratendinous Injections With Platelet-Rich Plasma or Autologous Whole Blood for Treatment of Proximal Hamstring Tendinopathy: A Double-Blind Randomized Controlled Trial.

    PubMed

    Davenport, Kathleen L; Campos, Jose Santiago; Nguyen, Joseph; Saboeiro, Gregory; Adler, Ronald S; Moley, Peter J

    2015-08-01

    To compare the effects of ultrasound-guided platelet-rich plasma (PRP) and whole blood (WB) injections in patients with chronic hamstring tendinopathy. In a prospective double-blind randomized controlled trial, PRP or WB was injected under ultrasound guidance into the proximal hamstring tendon in a cohort of patients with clinically suspected hamstring tendinosis. Questionnaires were administered before injection and 2, 6, and 12 weeks and 6 months after injection. Pain and function outcomes were measured via the Modified Harris Hip Score (MHHS), Hip Outcome Scores for activities of daily living (ADL) and sport-specific function, and International Hip Outcome Tool 33 (IHOT-33). Diagnostic ultrasound was used to compare preinjection and 6-month postinjection tendon appearances. The WB group showed greater improvements in pain and function over the PRP group before 12 weeks, whereas the PRP group showed improved outcomes over WB at 6 months. None of these between-group outcome measures, except 6-week IHOT-33, showed statistical significance. Comparing preinjection and 6-month scores, the PRP group showed significant improvements in ADL (P = .018) and IHOT-33 (P = .28) scores, whereas the WB group showed no significant improvements from baseline. The WB group showed significantly decreased pain with 15-minute sitting (P= .008) at 6 months. Ultrasound imaging showed no significant differences between PRP and WB group tendon appearances. Both PRP and WB groups showed improvements in all outcome measures at 6 months. The PRP group showed significant improvements in 6-month ADL and IHOT-33 scores. The WB group reached significance in 15-minute sitting pain. No significant between-group differences were observed at any time point. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Cryo-Assisted Resection En Bloc, and Cryoablation In Situ, of Primary Breast Cancer Coupled With Intraoperative Ultrasound-Guided Tracer Injection: A Preliminary Clinical Study.

    PubMed

    Korpan, Nikolai N; Xu, Kecheng; Schwarzinger, Philipp; Watanabe, Masashi; Breitenecker, Gerhard; Patrick, Le Pivert

    2018-01-01

    The aim of the study was to perform cryosurgery on a primary breast tumor, coupled with simultaneous peritumoral and intratumoral tracer injection of a blue dye, to evaluate lymphatic mapping. We explored the ability of our strategy to prevent tumor cells, but not that of injected tracers, to migrate to the lymphovascular drainage during conventional resection of frozen breast malignancies. Seventeen patients aged 51 (14) years (mean [standard deviation]), presenting primary breast cancer with stage I to IV, were randomly selected and treated in The Rudolfinerhaus Private Clinic in Vienna, Austria, and included in this preliminary clinical study. Under intraoperative ultrasound, 14 patients underwent curative cryo-assisted tumor resection en bloc, coupled with peritumoral tracer injection, which consisted of complete tumor freezing and concomitant peritumor injection with a blue dye, before resection and sentinel lymph node dissection (group A). Group B consists of 3 patients previously refused any standard therapy and had palliative tumor cryoablation in situ combined with intratumoral tracer injection. The intraoperative ultrasound facilitated needle positioning and dye injection timing. In group A, the frozen site extruded the dye that was distributed through the unfrozen tumor, the breast tissue, and the resection cavity for 12 patients. One to 4 lymph nodes were stained for 10 of 14 patients. The resection margin was evaluable. Our intraoperative ultrasound-guided performance revealed the injection and migration of a blue dye during the frozen resection en bloc and cryoablation in situ of primary breast tumors. Sentinel lymph node mapping, pathological determination of the tumor, and resection margins were achievable. The study paves the way for intraoperative cryo-assisted therapeutic strategies for breast cancer.

  15. Complications of botulinum toxin injections for treatment of esophageal motility disorders†.

    PubMed

    van Hoeij, Froukje B; Tack, Jan F; Pandolfino, John E; Sternbach, Joel M; Roman, Sabine; Smout, André J P M; Bredenoord, Albert J

    2017-02-01

    In achalasia and spastic esophageal motility disorders, botulinum toxin (botox) injection is considered an effective and low-risk procedure for short-term symptom relief. It is mainly offered to medically high-risk patients. However, no analysis of risks of botox injections has been performed. To determine the incidence and risk factors of procedure-related complications after esophageal botox injections, we analyzed the records of all patients undergoing botox injection therapy for esophageal motility disorders at four university hospitals in Europe and North America between 2008 and 2014. Complications were assigned grades according to the Clavien-Dindo classification. In 386 patients, 661 botox treatments were performed. Main indications were achalasia (51%) and distal esophageal spasm (DES) (30%). In total, 52 (7.9%) mild complications (Clavien-Dindo grade I) were reported by 48 patients, the majority consisting of chest pain or heartburn (29 procedures) or epigastric pain (5 procedures). No ulceration, perforation, pneumothorax, or abscess were reported. One patient died after developing acute mediastinitis (Clavien-Dindo grade V) following injections in the body of the esophagus. In univariate logistic regression, younger age was associated with an increased risk of complications (OR 1.43, 95%CI 1.03-1.96). Treatment for DES, injections into the esophageal body, more injections per procedure, more previous treatments and larger amount of injected botulinum toxin were no risk factors for complications. Esophageal botox injection seems particularly appropriate for high-risk patients due to low complication rate. However, it should not be considered completely safe, as it is associated with rare side effects that cannot be predicted. © 2016 International Society for Diseases of the Esophagus.

  16. Three-Year Analysis of Value and Utilization After Development of an Ultrasound-Based Orthopedic Injection Clinic.

    PubMed

    Dukes, Chase; Melton, Thomas; Turner, Eric; Jackson, Andrew; Grassbaugh, Jason; Slevin, John; Arrington, Edward D; Eichinger, Josef K

    2017-09-01

    Sonography is an effective method of diagnosing and treating musculoskeletal conditions, and the use of ultrasound has been shown to improve the accuracy, safety, and efficacy of both therapeutic and diagnostic injections. In 2012, we established an injection clinic at our institution to address our growing need for diagnostic and therapeutic injections. We performed an analysis of value and utilization following the development of an orthopedic injection clinic. This included an evaluation of the cost of materials, equipment, and training required to develop and run the clinic, and an analysis of the services rendered and relative value units (RVUs) generated over 3 fiscal years (FYs). The cost to develop the clinic was $42,498.30. The cost to run the clinic thereafter was $16.90 to $21.60 per injection. By the end of FY 2012, 60% of providers performed at least 1 injection under ultrasound guidance. Every successive year thereafter, 100% of providers were using ultrasound guidance. In FY 2012, we performed 738 injections, 5.4% used ultrasound guidance and generated a total of 1,786.36 RVUs. In FY 2013, we performed 1,814 injections, 17.6% used ultrasound guidance, and generated a total of 7,224.5 RVUs. In FY 2014, we performed 2,821 injections, 25.2% used ultrasound guidance, and generated 13,786.82 RVUs. RVUs generated solely from ultrasound guided injections were 463.2 (2012), 3,694 (2013), 8,221.8 (2014). Injection accuracy was at least 98%. Average time until injection was 0 days. The cost to start an injection clinic is modest, with the potential for large annual growth and early return on investment, and can generate significant revenue by recapturing RVUs that would otherwise be lost to outside referrals. Furthermore, it helps to increase clinic throughput, maximize services rendered during a single patient visit improving the overall quality of their encounter, expands the clinical practice of our midlevel providers, offloads clinical time for surgical

  17. In-vivo ultrasound and photoacoustic image- guided photothermal cancer therapy using silica-coated gold nanorods.

    PubMed

    Kim, Seungsoo; Chen, Yun-Sheng; Luke, Geoffrey P; Emelianov, Stanislav Y

    2014-05-01

    In nanoparticle-augmented photothermal therapy, evaluating the delivery and spatial distribution of nanoparticles, followed by remote temperature mapping and monitoring, is essential to ensure the optimal therapeutic outcome. The utility of ultrasound and photoacoustic imaging to assist photothermal therapy has been previously demonstrated. Here, using a mouse xenograft tumor model, it is demonstrated in vivo that ultrasound-guided photoacoustic imaging can be used to plan the treatment and to guide the therapy. To evaluate nanoparticle delivery and spatial distribution, three-dimensional ultrasound and spectroscopic photoacoustic imaging of a mouse with a tumor was performed before and after intravenous injection of silica-coated gold nanorods. After injection and sufficient circulation of nanoparticles, photothermal therapy was performed for 5 min using an 808-nm continuous-wave laser. During the photothermal therapy, photoacoustic images were acquired continuously and used to measure the temperature changes within tissue. A heterogeneous distribution of temperature, which was spatially correlated with the measured distribution of nanoparticles, indicated that peak temperatures of 53°C were achieved in the tumor. An Arrhenius thermal damage model determined that this thermal deposition would result in significant cell death. The results of this study suggest that ultrasound and photoacoustic imaging can effectively guide photothermal therapy to achieve the desired thermal treatment.

  18. Ultrasound-guided peripheral nerve blockade.

    PubMed

    Chin, Ki Jinn; Chan, Vincent

    2008-10-01

    The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.

  19. Technical Innovation Case Report: Ultrasound-Guided Prolotherapy Injection for Insertional Achilles Calcific Tendinosis

    PubMed Central

    DeLuca, Jesse P.; Lammlein, Kyle P.

    2016-01-01

    We describe the use of ultrasound guidance for hyperosmolar dextrose (prolotherapy) injection of the distal calcaneal tendon specifically just anterior to identified enthesophytes in patients with insertional Achilles calcific tendinosis refractory to conservative treatment. This specific technique has not to our knowledge been described or used in literature previously. PMID:27974984

  20. [Ultrasound-guided peripheral catheterization].

    PubMed

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  1. Management of Dupuytren contracture with ultrasound-guided lidocaine injection and needle aponeurotomy coupled with osteopathic manipulative treatment.

    PubMed

    Sampson, Steven; Meng, Michael; Schulte, Adam; Trainor, Drew; Montenegro, Roberto; Aufiero, Danielle

    2011-02-01

    Dupuytren contracture is a debilitating disease that characteristically presents as a firm nodularity on the palmar surface of the hand with coalescing cords of soft tissue on the webs and digits. With few nonsurgical modalities providing clinical benefits, open surgical procedures are the standard of care for patients with this condition. However, recent studies have associated surgical intervention with many complications, necessitating further exploration of nonsurgical treatment options. We describe the case of a 64-year-old woman who presented with decreased extension of the fourth and fifth digits on the upper extremities bilaterally; previous conservative treatment regimens had been unsuccessful. After a diagnostic ultrasound, the patient was diagnosed as having Dupuytren contracture and underwent 5 treatments consisting of ultrasound-guided dry-needle aponeurotomy, lidocaine injections, and osteopathic manipulative treatment. During the fifth treatment session, the patient experienced dramatic relief of her symptoms after a palpable release during the manual manipulation portion of her therapeutic regimen. At 2-week follow-up, the patient was symptom-free. Based on this desirable outcome, the authors suggest future research be directed at minimally invasive therapeutic options in the management of Dupuytren contracture.

  2. Treatment of Parkinson's disease in rats by Nrf2 transfection using MRI-guided focused ultrasound delivery of nanomicrobubbles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Ling; Cai, Xiaodong; Guo, Ruomi

    Parkinson's disease (PD) is a very common neurological disorder. However, effective therapy is lacking. Although the blood-brain-barrier (BBB) protects the brain, it prevents the delivery of about 90% of drugs and nucleotides into the brain, thereby hindering the development of gene therapy for PD. Magnetic resonance imaging (MRI)-guided focused ultrasound delivery of microbubbles enhances the delivery of gene therapy vectors across the BBB and improves transfection efficiency. In the present study, we delivered nuclear factor E2-related factor 2 (Nrf2, NFE2L2) contained in nanomicrobubbles into the substantia nigra of PD rats by MRI-guided focused ultrasound, and we examined the effect ofmore » Nrf2 over-expression in this animal model of PD. The rat model of PD was established by injecting 6-OHDA in the right substantia nigra stereotactically. Plasmids (pDC315 or pDC315/Nrf2) were loaded onto nanomicrobubbles, and then injected through the tail vein with the assistance of MRI-guided focused ultrasound. MRI-guided focused ultrasound delivery of nanomicrobubbles increased gene transfection efficiency. Furthermore, Nrf2 gene transfection reduced reactive oxygen species levels, thereby protecting neurons in the target region. - Highlights: • MRI-guided focused ultrasound enhances gene transfection into the brain of rats. • Increased Nrf2 expression protects neurons in the rat model of PD. • Nrf2 protects neurons in PD by inhibiting ROS production.« less

  3. Ultrasound-guided peripheral nerve interventions for common pain disorders

    PubMed Central

    Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh

    2018-01-01

    There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534

  4. [Prognostic analysis of plantar fasciitis treated by pneumatic ballistic extracorporeal shock wave versus ultrasound guided intervention].

    PubMed

    Huo, Xiu-Lin; Wang, Ke-Tao; Zhang, Xiao-Ying; Yang, Yi-Tian; Cao, Fu-Yang; Yang, Jing; Yuan, Wei-Xiu; Mi, Wei-Dong

    2018-02-20

    To compare the medium- and long-term effect of pneumatic ballistic extracorporeal shock wave versus ultrasound-guided hormone injection in the treatment of plantar fasciitis. The clinical data were collected from patients with plantar fasciitis admitted to PLA General Hospital pain department from September, 2015 to February, 2017. The patients were randomly divided into ultrasound-guided drug injection group and shock wave group. The therapeutic parameters including the numerical rating scale (NRS) scores in the first step pain in the morning, American Orthopedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale, and thickness of the plantar fascia were monitored before and at 1 week, 1 month, 3 months, and 6 months after the treatment. The recurrence rate, effectiveness, and patient satisfaction were compared between the two groups at 6 months after the treatment. Thirty-nine patients were enrolled in shock wave group and 38 patients in ultrasound group. The NRS scores in the first step pain in the morning were lowered after treatment in both groups (P<0.05), and the scores were significantly lower in ultrasound group than in shock wave group at 1 week and 1 month (P<0.01), but significantly higher in ultrasound group than in shock wave group at 3 and 6 months after treatment (P<0.05). The AOFAS functional scores were increased in both groups (P<0.05) at 6 months after treatment, was significantly lower in ultrasound group than in shock wave group than group B (90.44∓13.27 vs 75.76∓21.40; P<0.05). The effective rates in shock wave group and ultrasound group were 92.31% and 76.32%, respectively (P<0.05). Recurrence was found in 1 patient (2.56%) in shock wave group and in 8 (21.05%) in ultrasound group (P<0.05). The patient satisfaction scores were significantly higher in shock wave group than in ultrasound group (8.13∓2.67 vs 6.63∓3.75, P=0.048). Pneumatic ballistic extracorporeal shock achieves better medium- and long-term outcomes than ultrasound-guided

  5. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  6. Pain related to robotic cholecystectomy with lower abdominal ports: effect of the bilateral ultrasound-guided split injection technique of rectus sheath block in female patients

    PubMed Central

    Kim, Jin Soo; Choi, Jong Bum; Lee, Sook Young; Kim, Wook Hwan; Baek, Nam Hyun; Kim, Jayoun; Park, Chu Kyung; Lee, Yeon Ju; Park, Sung Yong

    2016-01-01

    Abstract Background: Robotic cholecystectomy (RC) using port sites in the lower abdominal area (T12-L1) rather than the upper abdomen has recently been introduced as an alternative procedure for laparoscopic cholecystectomy. Therefore, we investigated the time course of different components of pain and the analgesic effect of the bilateral ultrasound-guided split injection technique for rectus sheath block (sRSB) after RC in female patients. Methods: We randomly assigned 40 patients to undergo ultrasound-guided sRSB (RSB group, n = 20) or to not undergo any block (control group, n = 20). Pain was subdivided into 3 components: superficial wound pain, deep abdominal pain, and referred shoulder pain, which were evaluated with a numeric rating scale (from 0 to 10) at baseline (time of awakening) and at 1, 6, 9, and 24 hours postoperatively. Consumption of fentanyl and general satisfaction were also evaluated 1 hour (before discharge from the postanesthesia care unit) and 24 hours postoperatively (end of study). Results: Superficial wound pain was predominant only at awakening, and after postoperative 1 hour in the control group. Bilateral ultrasound-guided sRSB significantly decreased superficial pain after RC (P < 0.01) and resulted in a better satisfaction score (P < 0.05) 1 hour after RC in the RSB group compared with the control group. The cumulative postoperative consumption of fentanyl at 6, 9, and 24 hours was not significantly different between groups. Conclusions: After RC with lower abdominal ports, superficial wound pain predominates over deep intra-abdominal pain and shoulder pain only at the time of awakening. Afterwards, superficial and deep pain decreased to insignificant levels in 6 hours. Bilateral ultrasound-guided sRSB was effective only during the first hour. This limited benefit should be balanced against the time and risks entailed in performing RSB. PMID:27495072

  7. Minimum effective volume of mepivacaine for ultrasound-guided supraclavicular block

    PubMed Central

    Song, Jae Gyok; Kang, Bong Jin; Park, Kee Keun

    2013-01-01

    Background The aim of this study was to estimate the minimum effective volume (MEV) of 1.5% mepivacaine for ultrasound-guided supraclavicular block by placing the needle near the lower trunk of brachial plexus and multiple injections. Methods Thirty patients undergoing forearm and hand surgery received ultrasound-guided supraclavicular block with 1.5% mepivacaine. The initial volume of local anesthetic injected was 24 ml, and local anesthetic volume for the next patient was determined by the response of the previous patient. The next patient received a 3 ml higher volume in the case of the failure of the previous case. If the previous block was successful, the next volume was 3 ml lower. MEV was estimated by the Dixon and Massey up and down method. MEV in 95, 90, and 50% of patients (MEV95, MEV90, and MEV50) were calculated using probit transformation and logistic regression. Results MEV95 of 1.5% mepivacaine was 17 ml (95% confidence interval [CI], 13-42 ml), MEV90 was 15 ml (95% CI, 12-34 ml), and MEV50 was 9 ml (95% CI, 4-12 ml). Twelve patients had a failed block. Three patients received general anesthesia. Nine patients could undergo surgery with sedation only. Only one patient showed hemi-diaphragmatic paresis. Conclusions MEV95 was 17 ml, MEV90 was 15 ml, and MEV50 was 9 ml. However, needle location near the lower trunk of brachial plexus and multiple injections should be performed. PMID:23904937

  8. Acoustically active injection catheter guided by ultrasound: navigation tests in acutely ischemic porcine hearts.

    PubMed

    Belohlavek, Marek; Katayama, Minako; Zarbatany, David; Fortuin, F David; Fatemi, Mostafa; Nenadic, Ivan Z; McMahon, Eileen M

    2014-07-01

    Catheters are increasingly used therapeutically and investigatively. With complex usage comes a need for more accurate intracardiac localization than traditional guidance can provide. An injection catheter navigated by ultrasound was designed and then tested in an open-chest model of acute ischemia in eight pigs. The catheter is made "acoustically active" by a piezo-electric crystal near its tip, electronically controlled, vibrating in the audio frequency range and uniquely identifiable using pulsed-wave Doppler. Another "target" crystal was sutured to the epicardium within the ischemic region. Sonomicrometry was used to measure distances between the two crystals and then compared with measurements from 2-D echocardiographic images. Complete data were obtained from seven pigs, and the correlation between sonomicrometry and ultrasound measurements was excellent (p < 0.0001, ρ = 0.9820), as was the intraclass correlation coefficient (0.96) between two observers. These initial experimental results suggest high accuracy of ultrasound navigation of the acoustically active catheter prototype located inside the beating left ventricle. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Ultrasound-Guided Elbow Procedures.

    PubMed

    Sussman, Walter I; Williams, Christopher J; Mautner, Ken

    2016-08-01

    High-resolution ultrasonography can help clinicians visualize key anatomic structures of the elbow and guide periarticular and intra-articular injections. Historically, most procedures done around the elbow have been done using landmark guidance, and few studies have reported the accuracy of ultrasonography-guided injections in the elbow region. This article reviews common musculoskeletal disorders about the elbow that can be evaluated with ultrasonography, reviews the literature on ultrasonography-guided injections of the elbow region, and describes the senior author's preferred approach for the most commonly performed elbow region injections. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Development of future indications for BOTOX.

    PubMed

    Brin, Mitchell F

    2009-10-01

    Since the late 1970s, local injections of BoNT have provided clinical benefit for patients with inappropriately contracting muscles with or without pain or sensory disturbance. Marketing authorization for some BoNTs, depending on country, include core indications of dystonia (blepharospasm and cervical dystonia), large muscle spastic disorders (not yet approved in the United States, e.g., adult post-stroke spasticity and equinus foot deformity), hyperhidrosis and aesthetic. Subsequent development has extended to selected conditions characterized by recurrent or chronic pain (migraine headache), and urologic indications (neurogenic/idiopathic overactive bladder; prostate hyperplasia), with multiple additional opportunities available. Portfolio management requires a careful individual opportunity assessment of scientific and technical aspects (basic science foundation, potential to treat unmet medical need, product-specific risk in specific populations, therapeutic margin/safety profile, and probability of successful registration pathway). This article describes ongoing development targets for BOTOX.

  11. Evaluation of the painful athletic hip: imaging options and imaging-guided injections.

    PubMed

    Jacobson, Jon A; Bedi, Asheesh; Sekiya, Jon K; Blankenbaker, Donna G

    2012-09-01

    This article reviews diagnostic imaging tests and injections that provide important information for clinical management of patients with sports-related hip pain. In the evaluation of sports-related hip symptoms, MR arthrography is often used to evaluate intraarticular pathology of the hip. The addition of short- and long-acting anesthetic agents with the MR arthrography injection adds additional information that can distinguish between symptomatic and asymptomatic imaging findings. Osseous abnormalities can be characterized with radiography, MRI, or CT. Ultrasound is important in the assessment of iliopsoas abnormalities, including tendon snapping, and to guide diagnostic anesthetic injection.

  12. Efficacy and safety of closing postcatheterisation pseudoaneurysms with ultrasound-guided thrombin injections using two approaches: bolus versus slow injection. A prospective randomised trial.

    PubMed

    Lewandowski, Paweł; Maciejewski, Paweł; Wąsek, Wojciech; Pasierski, Tomasz; Budaj, Andrzej

    2011-01-01

    Thrombin injection is a widely accepted treatment of an iatrogenic arterial pseudoaneurysm. However, the optimal mode of injection and type of pseudoaneurysm amenable to this therapy have yet been established. To compare efficacy and safety of two approaches to ultrasound-guided thrombin injections into a femoral artery pseudoaneurysm with or without long neck that developed as an iatrogenic complication of cardiac catheterisation. Patients were randomised to thrombin administration in a bolus or slow injection. The length and width of aneurysm neck and blood flow velocity in the neck were measured with color Doppler ultrasonography before the closure procedure. Thrombin dose, time to thrombotic occlusion, blood oxygen saturation in a toe of the extremity with the pseudoaneurysm (a marker of silent microembolisation), and clinical signs of distal embolisation were recorded. Between 2006 and 2009, 73 consecutive patients (33 males; mean age 67.8 ± 11.9 years) with femoral pseudoaneurysms complicating cardiac catheterisation were randomised into two groups that were treated with thrombin bolus (n = 40) or slow injection (n = 33). The efficacy of aneurysm closure with either method was similarly high (100% vs 96.8%, NS, respectively) and did not depend on the length and width of the aneurysm neck. Independent risk factors for distal embolisation were: thrombin dose (OR 4.2; 95% CI 0.92-19.3), the length of aneurysm neck (OR 4.66; 95% CI 1.1-19.9), age above 80 years (OR 10.9; 95% CI 1.0-116.8), and bolus treatment (OR 7.6; 95% CI 1.3-44.9). We observed silent microembolisation phenomenon that was common (occurring in 38% of patients in the bolus group vs 33% of patients in the slow injection group) but in most cases asymptomatic. Femoral pseudoaneurysm closure with a low dose of thrombin is a valid and beneficial treatment. Either method (bolus or slow injection) was similarly efficacious and safe even in the subgroup of patients with neckless aneurysms. We observed

  13. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  14. Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation.

    PubMed

    Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y

    2017-08-01

    To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.

  15. Conventional Landmark-Guided Midline Versus Preprocedure Ultrasound-Guided Paramedian Techniques in Spinal Anesthesia.

    PubMed

    Kallidaikurichi Srinivasan, Karthikeyan; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2015-10-01

    Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of postdural puncture headache, paraesthesia, and spinal hematoma. We hypothesized that the routine use of a preprocedural ultrasound-guided paramedian technique for spinal anesthesia would reduce the number of passes required to achieve entry into the subarachnoid space when compared with the conventional landmark-guided midline approach. One hundred consenting patients scheduled for elective total joint replacements (hip and knee) were randomized into group C (conventional) and group P (preprocedural ultrasound-guided paramedian technique) with 50 in each group. The patients were blinded to the study group. All spinal anesthetics were administered by a consultant anesthesiologist. In group C, spinal anesthetic was done via the midline approach using clinically palpated landmarks. In group P, a preprocedural ultrasound scan was used to mark the paramedian insertion site, and spinal anesthetic was performed via the paramedian approach. The average number of passes (defined as the number of forward advancements of the spinal needle in a given interspinous space, i.e., withdrawal and redirection of spinal needle without exiting the skin) in group P was approximately 0.34 times that in group C, a difference that was statistically significant (P = 0.01). Similarly, the average number of attempts (defined as the number of times the spinal needle was withdrawn from the skin and reinserted) in group P was approximately 0.25 times that of group C (P = 0.0021). In group P, on an average, it took 81.5 (99% confidence interval, 68.4-97 seconds) seconds longer to identify the landmarks than in group C (P = 0.0002). All other parameters, including grading of palpated landmarks, time taken for spinal anesthetic injection, periprocedural pain scores, periprocedural patient discomfort visual analog scale score, conversion to general anesthetic, paresthesia, and radicular pain

  16. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  17. Ultrasound-guided corticosteroid injection of the subtalar joint for treatment of juvenile idiopathic arthritis.

    PubMed

    Young, Cody M; Horst, Deanna M; Murakami, James W; Shiels, William E

    2015-07-01

    The subtalar joint is commonly affected in children with juvenile idiopathic arthritis and is challenging to treat percutaneously. To describe the technique for treating the subtalar joint with US-guided corticosteroid injections in children and young adults with juvenile idiopathic arthritis and to evaluate the safety of the treatment. We retrospectively analyzed 122 patients (age 15 months-29 years) with juvenile idiopathic arthritis who were referred by a pediatric rheumatologist for corticosteroid injection therapy for symptoms related to the hindfoot or ankle. In these patients the diseased subtalar joint was targeted for therapy, often in conjunction with adjacent affected joints or tendon sheaths of the ankle. We used a protocol based on age, weight and joint for triamcinolone hexacetonide or triamcinolone acetonide dose prescription. We describe the technique for successful treatment of the subtalar joint. A total of 241 subtalar joint corticosteroid injections were performed under US guidance, including 68 repeat injections for recurrent symptoms in 26 of the 122 children and young adults. The average time interval between repeat injections was 24.8 months (range 2.2-130.7 months, median 14.2 months). Subcutaneous tissue atrophy and skin hypopigmentation were the primary complications observed. These complications occurred in 3.9% of the injections. With appropriate training and practice, the subtalar joint can be reliably and safely targeted with US-guided corticosteroid injection to treat symptoms related to juvenile idiopathic arthritis.

  18. Outcomes of ultrasound guided renal mass biopsies.

    PubMed

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  19. Penthrox inhaler analgesia in transrectal ultrasound-guided prostate biopsy.

    PubMed

    Lee, Chanyang; Woo, Henry H

    2015-06-01

    Periprostatic injection of local anaesthetic (PILA) has been shown to significantly reduce pain in patients undergoing transrectal ultrasound-guided prostate biopsy (TRUSPB). However, this method does not address pain that is associated with ultrasound probe insertion, and the injection of local anaesthetic itself causes pain. The aim of this study was to explore the efficacy of methoxyflurane delivered by a Penthrox inhaler as a novel method of pain relief during TRUSPB. From July 2012 to July 2013, 64 patients were scheduled at a single centre to undergo TRUSPB while receiving analgesia via Penthrox inhaler. Fifteen minutes after the biopsy procedure, these patients were asked to complete a pain score survey using a 10-cm visual analogue scale (VAS) to separately report the degree of pain experienced during digital rectal examination (DRE), ultrasound probe insertion and core biopsy. The median pain scores on a 10-cm VAS were 2.0, 2.4 and 3.0 during DRE, probe insertion and needle biopsy, respectively, while using the Penthrox inhaler. Of the 64 patients, 11 had undergone TRUSPB previously receiving PILA. In these patients, PILA was significantly better than the Penthrox inhaler for pain relief during needle biopsy (median pain score 2.0 versus 4.0; P = 0.012). The Penthrox inhaler appears to be a safe and effective method of analgesia for TRUSPB. Patients who had experienced both PILA and Penthrox reported pain scores that significantly favoured PILA over the Penthrox inhaler. © 2014 Royal Australasian College of Surgeons.

  20. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  1. Chronic abdominal wall pain and ultrasound-guided abdominal cutaneous nerve infiltration: a case series.

    PubMed

    Kanakarajan, Saravanakumar; High, Kristina; Nagaraja, Ravi

    2011-03-01

    Chronic abdominal wall pain occurs in about 10-30% of patients presenting with chronic abdominal pain. Entrapment of abdominal cutaneous nerves at the lateral border of the rectus abdominis muscle has been attributed as a cause of abdominal wall pain. We report our experience of treating such patients using ultrasound-guided abdominal cutaneous nerve infiltration. We conducted a retrospective audit of abdominal cutaneous nerve infiltration performed in the period between September 2008 to August 2009 in our center. All patients had received local anesthetic and steroid injection under ultrasound guidance. The response to the infiltration was evaluated in the post-procedure telephone review as well as in the follow-up clinic. Brief pain inventory (BPI) and numerical rating scale pain scores were collated from two points: the initial outpatient clinic and the follow up clinic up to 5 months following the injection. Nine patients had abdominal cutaneous nerve injections under ultrasound guidance in the period under review. Six patients reported 50% pain relief or more (responders) while three patients did not. Pain and BPI scores showed a decreasing trend in responders. The median duration of follow-up was 12 weeks. Ultrasound can reliably be used for infiltration of the abdominal cutaneous nerves. This will improve the safety as well as diagnostic utility of the procedure. Wiley Periodicals, Inc.

  2. Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.

    PubMed

    Ajmal, Muhammad; Power, Susan; Smith, Tim; Shorten, George D

    2011-02-01

    To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting. Pilot prospective observational study. Orthopedic operating room of a regional trauma hospital. 15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire. The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion. Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Ultrasound-guided chest biopsies.

    PubMed

    Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar

    2006-12-01

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.

  4. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    PubMed

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  5. Ultrasound-guided approach to the cervical articular process joints in horses: a validation of the technique in cadavers.

    PubMed

    Purefoy Johnson, Jessica; Stack, John David; Rowan, Conor; Handel, Ian; O'Leary, John Mark

    2017-05-22

    To compare accuracy of the ultrasound-guided craniodorsal (CrD) approach with the dorsal (D) approach to the cervical articular process joints, and to evaluate the effect of the transducer, needle gauge, and operator experience. Cervical articular process joints from 14 cadaveric neck specimens were injected using either a D or CrD approach, a linear (13 MHx) or microconvex transducer (10 MHz), and an 18 or 20 gauge needle, by an experienced or inexperienced operator. Injectate consisted of an iodinated contrast material solution. Time taken for injection, number of redirects, and retrieval of synovial fluid were recorded. Accuracy was assessed using a scoring system for contrast seen on computed tomography (CT). The successful performance of intra-articular injections of contrast detected by CT using the D (61/68) and CrD (57/64) approaches was comparable. No significant effect of approach, transducer or needle gauge was observed on injection accuracy, time taken to perform injection, or number of redirects. The 18 gauge needle had a positive correlation with retrieval of synovial fluid. A positive learning curve was observed for the inexperienced operator. Both approaches to the cervical articular process joints were highly accurate. Ultrasound-guided injection of the cervical articular process joints is an easily-learnt technique for an inexperienced veterinarian. Either approach may be employed in the field with a high level of accuracy, using widely available equipment.

  6. [Clinical effect of ultrasound-guided injection of biodegradable poly(lactic-co-glycolic acid)-Fe3O4 in situ implant for magnetic thermal ablation in treatment of nude mice with human liver cancer SMMC-7721 cells].

    PubMed

    Liang, B; Zuo, G Q; Zheng, Y Y; He, S; Zuo, D Y

    2016-12-20

    Objective: To prepare the Fe 3 O 4 -loaded biodegradable liquid-solid phase inversion poly(lactic-co-glycolic acid) (PLGA) in situ implant for ultrasound-guided injection into nude mouse tumor model, and to investigate its clinical effect in thermomagnetic treatment of nude mice with human liver cancer SMMC-7721 cells in an alternating magnetic field. Methods: An in situ implant containing 10% Fe 3 O 4 was prepared, and 50 μl Fe 3 O 4 -PLGA-NMP gel was injected into the subcutaneous tissue of Kunming mice. The degradation of this material was observed for 2 consecutive months, and the changes in body weight were recorded. HE staining and Prussian blue staining were performed for the heart, liver, spleen, lung, and kidney of Kunming mice. Fresh ex vivo bovine liver was taken and cut into cubes with a dimension of 2 cm×2 cm×2 cm and then 50 μl Fe 3 O 4 -PLGA-NMP gel was injected; after phase inversion, the cubes of ex vivo bovine liver were heated for 1, 2, 3, 4, and 5 minutes, respectively, and then cut open for observing the range of ablation; HE staining was also performed. Micro-CT scan was performed after ultrasound-guided injection of 50 μl Fe 3 O 4 -PLGA gel into the tumors of the nude mice, and then the nude mice were divided into treatment group and control group. The mice in the treatment group were given thermomagnetic treatment for 3 minutes, and tumor growth was observed daily. Results: The biodegradation of Fe 3 O 4 -PLGA-NMP implant showed that the subcutaneously injected material was gradually metabolized at 2 weeks after injection and that the nude mice were in good condition. The bovine liver ablation experiment showed that the range of ablation of 50 μl Fe 3 O 4 -PLGA implant reached 1.46 ± 0.11 cm. HE staining showed that part of bovine liver had coagulative necrosis. The phase inversion experiment of Fe 3 O 4 -PLGA gel showed quick liquid-solid phase inversion of the material after injection into the tumor, and the process of liquid

  7. Development of an ultrasound-guided technique for pudendal nerve block in cat cadavers.

    PubMed

    Adami, Chiara; Angeli, Giovanni; Haenssgen, Kati; Stoffel, Michael H; Spadavecchia, Claudia

    2013-10-01

    The objective of this prospective experimental cadaveric study was to develop an ultrasound-guided technique to perform an anaesthetic pudendal nerve block in male cats. Fifteen fresh cadavers were used for this trial. A detailed anatomical dissection was performed on one cat in order to scrutinise the pudendal nerve and its ramifications. In a second step, the cadavers of six cats were used to test three different ultrasonographic approaches to the pudendal nerve: the deep dorso-lateral, the superficial dorso-lateral and the median transperineal. Although none of the approaches allowed direct ultrasonographical identification of the pudendal nerve branches, the deep dorso-lateral was found to be the most advantageous one in terms of practicability and ability to identify useful and reliable landmarks. Based on these findings, the deep dorso-lateral approach was selected as technique of choice for tracer injections (0.1 ml 1% methylene blue injected bilaterally) in six cat cadavers distinct from those used for the ultrasonographical study. Anatomical dissection revealed a homogeneous spread of the tracer around the pudendal nerve sensory branches in all six cadavers. Finally, computed tomography was performed in two additional cadavers after injection of 0.3 ml/kg (0.15 ml/kg per each injection sites, left and right) contrast medium through the deep dorso-lateral approach in order to obtain a model of volume distribution applicable to local anaesthetics. Our findings in cat cadavers indicate that ultrasound-guided pudendal nerve block is feasible and could be proposed to provide peri-operative analgesia in clinical patients undergoing perineal urethrostomy.

  8. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    PubMed

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  9. High volume ultrasound guided injections at the interface between the patellar tendon and Hoffa's body are effective in chronic patellar tendinopathy: A pilot study.

    PubMed

    Crisp, Tom; Khan, Faisal; Padhiar, Nat; Morrissey, Dylan; King, John; Jalan, Rosy; Maffulli, Nicola; Frcr, Otto Chan

    2008-01-01

    To evaluate a novel conservative management modality for patellar tendinopathy. We recruited nine patients with patellar tendinopathy who had failed conservative management and showed evidence of neovascularisation on power Doppler scanning. A high volume ultrasound guided injection at the interface between the patellar tendon and Hoffa's body. The injection contained 10 ml 0.5% Bupivacaine, 25 mg Hydrocortisone, and between 12 and 40 ml normosaline. 100 mm visual analogue scales (VAS) for pain and for function, and Victorian Institute of Sport Assessment - Patellar tendon (VISA-P) questionnaires at an average of 9 months from the injection. All but one patient (whose pain was unchanged) improved (p = 0.028). The mean improvement in function 2 weeks after injection was 58 mm on VAS (interquartile range 27 - 88, p = 0.018). The mean improvement in pain 2 weeks after injection was 56 mm on a VAS scale (interquartile range 32 - 80, p = 0.018). At a mean follow up of 9 months, an improvement of 22 points from a baseline score of 46 on the VISA-P questionnaire (100 being normal) was established. High volume injections to mechanically disrupt the neovascularisation in patellar tendinopathy are helpful in the management of this condition. Controlled trials would be warranted to investigate in a more conclusive fashion this management modality.

  10. [Ultrasound guided percutaneous nephrolithotripsy].

    PubMed

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  11. Pain related to robotic cholecystectomy with lower abdominal ports: effect of the bilateral ultrasound-guided split injection technique of rectus sheath block in female patients: A prospective randomised trial.

    PubMed

    Kim, Jin Soo; Choi, Jong Bum; Lee, Sook Young; Kim, Wook Hwan; Baek, Nam Hyun; Kim, Jayoun; Park, Chu Kyung; Lee, Yeon Ju; Park, Sung Yong

    2016-08-01

    Robotic cholecystectomy (RC) using port sites in the lower abdominal area (T12-L1) rather than the upper abdomen has recently been introduced as an alternative procedure for laparoscopic cholecystectomy. Therefore, we investigated the time course of different components of pain and the analgesic effect of the bilateral ultrasound-guided split injection technique for rectus sheath block (sRSB) after RC in female patients. We randomly assigned 40 patients to undergo ultrasound-guided sRSB (RSB group, n = 20) or to not undergo any block (control group, n = 20). Pain was subdivided into 3 components: superficial wound pain, deep abdominal pain, and referred shoulder pain, which were evaluated with a numeric rating scale (from 0 to 10) at baseline (time of awakening) and at 1, 6, 9, and 24 hours postoperatively. Consumption of fentanyl and general satisfaction were also evaluated 1 hour (before discharge from the postanesthesia care unit) and 24 hours postoperatively (end of study). Superficial wound pain was predominant only at awakening, and after postoperative 1 hour in the control group. Bilateral ultrasound-guided sRSB significantly decreased superficial pain after RC (P < 0.01) and resulted in a better satisfaction score (P < 0.05) 1 hour after RC in the RSB group compared with the control group. The cumulative postoperative consumption of fentanyl at 6, 9, and 24 hours was not significantly different between groups. After RC with lower abdominal ports, superficial wound pain predominates over deep intra-abdominal pain and shoulder pain only at the time of awakening. Afterwards, superficial and deep pain decreased to insignificant levels in 6 hours. Bilateral ultrasound-guided sRSB was effective only during the first hour. This limited benefit should be balanced against the time and risks entailed in performing RSB.

  12. Ultrasound guided injection inside the common sheath of the sciatic nerve at division level has a higher success rate than an injection outside the sheath.

    PubMed

    Lopez, A M; Sala-Blanch, X; Castillo, R; Hadzic, A

    2014-01-01

    The recommendations for the level of injection and ideal placement of the needle tip required for successful ultrasound-guided sciatic popliteal block vary among authors. A hypothesis was made that, when the local anesthetic is injected at the division of the sciatic nerve within the common connective tissue sheath, the block has a higher success rate than an injection outside the sheath. Thirty-four patients scheduled for hallux valgus repair surgery were randomized to receive either a sub-sheath block (n=16) or a peri-sheath block (n=18) at the level of the division of the sciatic nerve at the popliteal fossa. For the sub-sheath block, the needle was advanced out of plane until the tip was positioned between the tibial and peroneal nerves, and local anesthetic was then injected without moving the needle. For the peri-sheath block, the needle was advanced out of plane both sides of the sciatic nerve, to surround the sheath. Mepivacaine 1.5% and levobupivacaine 0.5% 30mL were used in both groups. The progression of motor and sensory block was assessed at 5min intervals. Duration of block was recorded. Adequate surgical block was achieved in all patients in the subsheath group (100%) compared to 12 patients (67%) in the peri-sheath group at 30min. Sensory block was achieved faster in the subsheath than peri-sheath (9.1±7.4min vs. 19.0±4.0; p<.001). Our study suggests that for successful sciatic popliteal block in less than 30min, local anesthetic should be injected within the sheath. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  13. Descriptive Cadaveric Study Comparing the Accuracy of Ultrasound Versus Fluoroscopic Guidance for First Sacral Transforaminal Injections: A Comparison Study.

    PubMed

    Thompson, Bradley F; Pingree, Matthew J; Qu, Wenchun; Murthy, Naveen S; Lachman, Nirusha; Hurdle, Mark Friedrich

    2018-04-01

    Ultrasound is rarely used for guiding lumbosacral epidural steroid injections due to its technical limitations. For example, sonographic imaging lacks the ability to confirm epidural spread and identify vascular uptake. The perceived risk that these limitations pose to human subjects has precluded any large scale clinical trials to date. To compare the accuracy of ultrasound versus fluoroscopic guidance for first sacral transforaminal epidural injections. Cadaveric comparative study using dichotomous outcomes. A fluoroscopy suite and anatomic laboratory at an academic medical center. Four unembalmed adult human cadavers with no history of spinal surgery. Eight sites were injected twice by one interventionalist, using fluoroscopic and ultrasound guidance. In the fluoroscopy arm, contrast spread was assessed using computed tomography. In the ultrasound arm, latex spread was assessed using gross anatomic dissection. Any visible evidence of epidural spread constituted a positive result. Comparison of the success of obtaining epidural contrast flow was the primary outcome measure. Secondary outcome measures included average duration, rate of intravascular uptake, and quantity of intravascular uptake. All injections performed in both the ultrasound arm and the fluoroscopy arm had positive epidural spread. The average duration was 3.03 minutes with fluoroscopy and 4.76 minutes with ultrasound. The rate of intravascular uptake was 37.5% with fluoroscopy and 50% with ultrasound. Within the ultrasound arm, greater intravascular spread and duration variability were recorded. Although ultrasonography can provide reliable image guidance for cannulating the first sacral foramen in cadavers, it would have limited clinical utility due to its inability to visualize relevant neurovascular structures deep to the osseus roof and exclude intravascular uptake. IV. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  14. Botox combined with myofascial release physical therapy as a treatment for myofascial pelvic pain

    PubMed Central

    Scott, Lauren; Wyman, Allison; Mora, Nelsi; Miladinovic, Branko; Bassaly, Renee; Hoyte, Lennox

    2017-01-01

    Purpose To report the effects of combined onabotulinumtoxinA (Botox) injections and myofascial release physical therapy on myofascial pelvic pain (MFPP) by comparing pre- and posttreatment average pelvic pain scores, trigger points, and patient self-reported pelvic pain. Secondary outcomes were to examine posttreatment complications and determine demographic differences between patients with/without an improvement in pain. Materials and Methods This was an Institutional Review Board approved retrospective case series on women over 18 years with MFPP who received Botox and physical therapy between July 2006 and November 2014. Presence of trigger points and pelvic pain scores were determined by digital palpation of the iliococcygeus, puborectalis, obturator internus, and rectus muscles. Average pelvic pain scores (0–10) reflected an average of the scores obtained from palpation of each muscle. Self-reported improvement in pain was recorded as yes/no. Results Fifty women met the inclusion/exclusion criteria. Posttreatment, patients had lower average pelvic pain scores (3.7±4.0 vs. 6.4±1.8, p=0.005), and fewer trigger points (44% vs. 100%, p<0.001). Fifty-eight percent of patients (95% confidence interval, 44–72) noted an improvement in self-reported pain. Patients most likely to report no improvement in pain had chronic bowel disorders, while those most likely to report an improvement in pain had a history of past incontinence sling (p=0.03). Posttreatment complications included: constipation (8%), worsening urinary retention (2%), and urinary tract infection (4%). Conclusions Botox combined with soft tissue myofascial release physical therapy under anesthesia can be effective in treating women with chronic pelvic pain secondary to MFPP. PMID:28261683

  15. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    PubMed

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  16. Analysis of "dry" mesothelioma with ultrasound guided biopsies.

    PubMed

    Stigt, Jos A; Boers, James E; Groen, Harry J M

    2012-12-01

    Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Block of the superior cervical ganglion, description of a novel ultrasound-guided technique in human cadavers.

    PubMed

    Siegenthaler, Andreas; Haug, Matthias; Eichenberger, Urs; Suter, Marc Rene; Moriggl, Bernhard

    2013-05-01

    Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks. Wiley Periodicals, Inc.

  18. Ultrasound-Guided Treatment of Peripheral Nerve Pathology.

    PubMed

    Dettori, Nathan; Choudur, Hema; Chhabra, Avneesh

    2018-07-01

    High-resolution ultrasound serves as a fast, accessible, reliable, and radiation-free tool for anatomical and dynamic evaluation of various peripheral nerves. It can be used not only to identify and diagnose peripheral nerve and perineural pathology accurately but also to guide various nerve and perineural interventions. We describe the normal and pathologic appearances of peripheral nerves, the pathologies commonly affecting the individual peripheral nerves, and the current ultrasound-guided peripheral nerve interventions and techniques. Future directions are also highlighted. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Successful Treatment of Gluteal Pain from Obturator Internus Tendinitis and Bursitis with Ultrasound-Guided Injection.

    PubMed

    Chen, Boqing; Rispoli, Leia; Stitik, Todd; Leong, Michelle

    2017-10-01

    This case report describes what the authors believe is the first case of a patient with obturator internus tendinitis and bursitis successfully treated with a corticosteroid injection using a trans-tendinous lateral to medial approach. The patient presented with right gluteal pain not relieved by physical therapy or right hip and ischial bursa corticosteroid injections. Pelvic and lumbar spine MRIs and EMG/NCS findings were unremarkable. Physical examination demonstrated tenderness to palpation at the right middle lower gluteal region. Ultrasound imaging with sonopalpation identified the maximal local tender point as the right obturator internus muscle and/or its underlying bursa. A 22-gauge 3.5-inch needle was inserted in-plane to the transducer and longitudinal to the obturator internus from a lateral to medial direction, an approach previously described in cadavers. The obturator internus tendon sheath and bursa were injected with 2.5 ml of 0.5% lidocaine combined with 10 mg of triamcinolone. The patient reported immediate complete relief of pain with continued relief at 2 and 6 months post-injection. This case report demonstrates an injection of the obturator internus tendon sheath and bursa using a trans-tendinous approach, which may be successful for treatment of patients presenting with persistent gluteal pain from obturator internus tendinitis and bursitis.

  20. Ultrasound-guided venous access for pacemakers and defibrillators.

    PubMed

    Seto, Arnold H; Jolly, Aaron; Salcedo, Jonathan

    2013-03-01

    Ultrasound guidance is widely recommended to reduce the risk of complications during central venous catheter placement. However, ultrasound guidance is not commonly utilized for implanting leads for cardiac rhythm management devices. We describe our technique of ultrasound-guided pacemaker implantation, including a novel pull-through technique that allows percutaneous guidewire insertion prior to the first incision. We review the literature and recent advances in ultrasound imaging technology that may facilitate the adoption of ultrasound guidance. Ultrasound guidance provides a safe and rapid technique for extrathoracic subclavian or axillary venous lead placement. © 2012 Wiley Periodicals, Inc.

  1. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    PubMed Central

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  2. Augmented Reality-Guided Lumbar Facet Joint Injections.

    PubMed

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P < 0.001 for both readers). Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  3. Polyplex-microbubble hybrids for ultrasound-guided plasmid DNA delivery to solid tumors.

    PubMed

    Sirsi, Shashank R; Hernandez, Sonia L; Zielinski, Lukasz; Blomback, Henning; Koubaa, Adel; Synder, Milo; Homma, Shunichi; Kandel, Jessica J; Yamashiro, Darrell J; Borden, Mark A

    2012-01-30

    Microbubble ultrasound contrast agents are being developed as image-guided gene carriers for targeted delivery in vivo. In this study, novel polyplex-microbubbles were synthesized, characterized and evaluated for systemic circulation and tumor transfection. Branched polyethylenimine (PEI; 25 kDa) was modified with polyethylene glycol (PEG; 5 kDa), thiolated and covalently attached to maleimide groups on lipid-coated microbubbles. The PEI-microbubbles demonstrated increasingly positive surface charge and DNA loading capacity with increasing maleimide content. The in vivo ultrasound contrast persistence of PEI-microbubbles was measured in the healthy mouse kidney, and a two-compartment pharmacokinetic model accounting for free and adherent microbubbles was developed to describe the anomalous time-intensity curves. The model suggested that PEI loading dramatically reduced free circulation and increased nonspecific adhesion to the vasculature. However, DNA loading to form polyplex-microbubbles increased circulation in the bloodstream and decreased nonspecific adhesion. PEI-microbubbles coupled to a luciferase bioluminescence reporter plasmid DNA were shown to transfect tumors implanted in the mouse kidney. Site-specific delivery was achieved using ultrasound applied over the tumor area following bolus injection of the DNA/PEI-microbubbles. In vivo imaging showed over 10-fold higher bioluminescence from the tumor region compared to untreated tissue. Ex vivo analysis of excised tumors showed greater than 40-fold higher expression in tumor tissue than non-sonicated control (heart) tissue. These results suggest that the polyplex-microbubble platform offers improved control of DNA loading and packaging suitable for ultrasound-guided tissue transfection. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Ultrasound-Guided Pulsed Radiofrequency Stimulation of Posterior Tibial Nerve: A Potential Novel Intervention for Recalcitrant Plantar Fasciitis.

    PubMed

    Wu, Yung-Tsan; Chang, Chih-Ya; Chou, Yu-Ching; Yeh, Chun-Chang; Li, Tsung-Ying; Chu, Heng-Yi; Chen, Liang-Cheng

    2017-05-01

    To evaluate the therapeutic benefit of ultrasound-guided pulsed radiofrequency (PRF) stimulation at the posterior tibial nerve (PTN) in patients with recalcitrant plantar fasciitis (PF). A prospective, randomized, double-blinded, placebo-controlled trial (12-wk follow-up). Outpatient local medical center settings. Patients (N=36) with recalcitrant PF underwent randomization, and all were included in the final data analysis. Patients in the PRF group were treated with 1 dose of ultrasound-guided PRF stimulation at the PTN, and those in the control group received 1 dose of 2% lidocaine, 0.5mL, injected at the PTN under ultrasound guidance. The visual analog scale (first-step and overall pain), American Orthopedic Foot-Ankle Society (AOFAS) ankle-hindfoot scale, and ultrasonographic thickness of the plantar fascia were evaluated at 1, 4, 8, and 12 weeks after treatment. Thirty-six patients (20 feet per group) completed the study. The PRF group had a significantly larger improvement in first-step pain, overall pain, and AOFAS score (all P<.001), as well as plantar fascia thickness (P<.05), compared with those of the control group at all observed time points. This study shows that ultrasound-guided PRF stimulation at the PTN is effective for treating recalcitrant PF. This simple, reproducible method could be a novel strategy for managing recalcitrant PF. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Efficacy of Combined Ultrasound-Guided Steroid Injection and Splinting in Patients With Carpal Tunnel Syndrome: A Randomized Controlled Trial.

    PubMed

    Wang, Jia-Chi; Liao, Kwong-Kum; Lin, Kon-Ping; Chou, Chen-Liang; Yang, Tsui-Fen; Huang, Yu-Fang; Wang, Kevin A; Chiu, Jan-Wei

    2017-05-01

    To compare the effectiveness of local steroid injection plus splinting with that of local steroid injection alone using clinical and electrophysiological parameters in patients with carpal tunnel syndrome (CTS). Randomized controlled study with 12 weeks of follow-up. Tertiary care center. Volunteer sample of patients (N=52) diagnosed with CTS. Participants were randomly assigned to the steroid injection group (n=26) or the steroid injection-plus-splinting group (n=26). Patients of both groups received ultrasound-guided steroid injection with 1mL of 10mg (10mg/mL) triamcinolone acetonide (Shincort) and 1mL of 2% lidocaine hydrochloride (Xylocaine). Participants in the second group also wore a volar splint in the neutral position while sleeping and also during daytime whenever possible for the 12-week intervention period. Participants were evaluated before the treatment and at 6 and 12 weeks after the onset of treatment. The primary outcome measure was Boston Carpal Tunnel Questionnaire scores. The secondary outcome measures were as follows: scores on the visual analog scale for pain; electrophysiological parameters, including median nerve distal motor latency, sensory nerve conduction velocity (SNCV), and compound muscle action potential and sensory nerve action potential (SNAP) amplitudes; and patient's subjective impression of improvement. At 12-week follow-up, improvements in symptom severity and functional status scores on the Boston Carpal Tunnel Questionnaire as well as SNCV and SNAP amplitudes were greater in the group that received steroid injection combined with splinting than in the group that received steroid injection alone. The between-group difference was .48 points (95% confidence interval [CI], .09-.88 points; P=.032) in the Symptom Severity Scale score, .37 points (95% CI, .06-.67 points; P=.019) in the Functional Status Scale score, 3.38m/s (95% CI, 0.54-6.22m/s; P=.015) in the SNCV amplitude, and 3.21μV (95% CI, 0.00-6.46μV; P=.025) in the SNAP

  6. Ultrasound - Aided ejection in micro injection molding

    NASA Astrophysics Data System (ADS)

    Masato, D.; Sorgato, M.; Lucchetta, G.

    2018-05-01

    In this work, an ultrasound-aided ejection system was designed and tested for different polymers (PS, COC and POM) and mold topographies. The proposed solution aims at reducing the ejection friction by decreasing the adhesion component of the frictional force, which is controlled by the contact area developed during the filling stage of the injection molding process. The experimental results indicate a positive effect of ultrasound vibration on the friction force values, with a maximum reduction of 16. Moreover, it is demonstrated that the ultrasound effect is strictly related to both polymer selection and mold roughness. The combined effect on the ejection force of mold surface roughness, melt viscosity during filling and polymer elastic modulus at ejection was modeled to the experimental data, in order to demonstrate that the effect of ultrasound vibration on the ejection friction reduction is due to the heating of the contact interface and the consequent reduction of the polymer elastic modulus.

  7. Real-Time Ultrasound-Guided Spinal Anaesthesia: A Prospective Observational Study of a New Approach

    PubMed Central

    Conroy, P. H.; Luyet, C.; McCartney, C. J.; McHardy, P. G.

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1–6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83–4.1) demonstrating the feasibility of this technique in routine clinical practice. PMID:23365568

  8. Ultrasound-guided shoulder MR arthrography: comparison of rotator interval and posterior approach.

    PubMed

    Ogul, Hayri; Bayraktutan, Ummugulsum; Ozgokce, Mesut; Tuncer, Kutsi; Yuce, Ihsan; Yalcin, Ahmet; Pirimoglu, Berhan; Sagsoz, Erdem; Kantarci, Mecit

    2014-01-01

    The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for magnetic resonance (MR) arthrography of the shoulder. This study included 100 patients [50 rotator interval group (n=50) vs. 50 posterior approach group (n=50)]. All procedures were performed by the same radiologist. The two injection techniques were compared. The discomfort during and after arthrography was evaluated. Extraarticular contrast media extravasation was graded according to the MRI findings. The number of injection attempts, effect of contrast media extravasation rate on diagnostic quality and procedure times were recorded. There were no significant difference between the posterior and rotator interval puncture groups with regard to pain (P=.915), procedure times (P=.401) or attempt scores (P=.182). There were significantly more contrast media extravasations with rotator interval approach than posterior approach (P<.05). Both techniques were successful and well tolerated by patients. Posterior injection technique provided a more effective route with decreased extravasation rate and easier approach compared to the rotator interval approach. © 2014.

  9. Botulinum toxin injections for the treatment of hemifacial spasm over 16 years.

    PubMed

    Sorgun, Mine Hayriye; Yilmaz, Rezzak; Akin, Yusuf Alper; Mercan, Fatma Nazli; Akbostanci, Muhittin Cenk

    2015-08-01

    The aim of this study was to investigate the efficacy and side effects of botulinum toxin (BTX) in the treatment of hemifacial spasm (HFS). We also focused on the divergence between different injection techniques and commercial forms. We retrospectively evaluated 470 sessions of BTX injections administered to 68 patients with HFS. The initial time of improvement, duration and degree of improvement, and frequency and duration of adverse effects were analysed. Pretarsal and preseptal injections and Botox (Allergan, Irvine, CA, USA) and Dysport (Ipsen Biopharmaceuticals, Paris, France) brands were compared in terms of efficacy and side effects, accompanied by a review of papers which reported BTX treatment of HFS. An average of 34.5 units was used per patient. The first improvement was felt after 8 days and lasted for 14.8 weeks. Patients experienced a 73.7% improvement. In 79.7% of injections, no adverse effect was reported, in 4.9% erythema, ecchymosis, and swelling in the injection area, in 3.6% facial asymmetry, in 3.4% ptosis, in 3.2% diplopia, and in 2.3% difficulty of eye closure was detected. Patients reported 75% improvement on average after 314 sessions of pretarsal injections and 72.7% improvement after 156 sessions of preseptal injections (p=0.001). The efficacy and side effects of Botox and Dysport were similar. BTX is an effective and safe treatment option for HFS. No difference was determined between Botox and Dysport, and pretarsal injection is better than preseptal injection regarding the reported degree of improvement. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.

    PubMed

    Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs

    2012-08-01

    Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.

  11. Ultrasound-guided supraclavicular block: outcome of 510 consecutive cases.

    PubMed

    Perlas, Anahi; Lobo, Giovanni; Lo, Nick; Brull, Richard; Chan, Vincent W S; Karkhanis, Reena

    2009-01-01

    Supraclavicular brachial plexus block provides consistently effective anesthesia to the upper extremity. However, traditional nerve localization techniques may be associated with a high risk of pneumothorax. In the present study, we report block success and clinical outcome data from 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery. After institutional review board approval, the outcome of 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery was reviewed. Real-time ultrasound guidance was used with a high-frequency linear probe. The neurovascular structures were imaged on short axis, and the needle was inserted using an in-plane technique with either a medial-to-lateral or lateral-to-medial orientation. Five hundred ten ultrasound-guided supraclavicular blocks were performed (50 inpatients, 460 outpatients) by 47 different operators at different levels of training over a 24-month period. Successful surgical anesthesia was achieved in 94.6% of patients after a single attempt; 2.8% required local anesthetic supplementation of a single peripheral nerve territory; and 2.6% received an unplanned general anesthetic. No cases of clinically symptomatic pneumothorax developed. Complications included symptomatic hemidiaphragmatic paresis (1%), Horner syndrome (1%), unintended vascular punctures (0.4%), and transient sensory deficits (0.4%). Ultrasound-guided supraclavicular block is associated with a high rate of successful surgical anesthesia and a low rate of complications and thus may be a safe alternative for both inpatients and outpatients. Severe underlying respiratory disease and coagulopathy should remain a contraindication for this brachial plexus approach.

  12. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  13. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  14. Pregnancies following ultrasound-guided drainage of tubo-ovarian abscess.

    PubMed

    Gjelland, Knut; Granberg, Seth; Kiserud, Torvid; Wentzel-Larsen, Tore; Ekerhovd, Erling

    2012-07-01

    To study fertility among women treated by means of ultrasound-guided drainage and antibiotics for tubo-ovarian abscess (TOA). Retrospective cohort study. A tertiary referral center. One hundred women of reproductive age treated for TOA between June 1986 and July 2003. Transvaginal ultrasound-guided drainage of TOA was performed in all patients. The procedure was repeated if a substantial amount of pus was seen using ultrasonography 2-5 days after the initial aspiration, and repeated later if necessary. Frequency of naturally conceived pregnancies. Twenty of 38 (52.6%; 95% CI 36.5-68.9%) women who intended to have a child achieved pregnancy naturally and became mothers. In addition, 7 (50%) of 14 women who were not on birth control on a regular basis became pregnant. No ectopic pregnancies were registered. Ultrasound-guided drainage of TOA in combination with antibiotics seems to preserve fertility in approximately half of the patients. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  15. Transurethral ultrasound-guided laser-induced prostatectomy

    NASA Astrophysics Data System (ADS)

    Babayan, Richard K.; Roth, Robert A.

    1991-07-01

    A transurethral ultrasound-guided Nd:YAG laser delivery system has been developed for use as an alternative approach to the treatment of benign prostatic hyperplasia. The TULIP system has been extensively tested in canine models and is currently undergoing FDA trials in humans.

  16. Focused ultrasound guided relocation of kidney stones.

    PubMed

    Abrol, Nitin; Kekre, Nitin S

    2015-01-01

    Complete removal of all fragments is the goal of any intervention for urinary stones. This is more important in lower pole stones where gravity and spatial orientation of lower pole infundibulum may hinder spontaneous passage of fragments. Various adjuvant therapies (inversion, diuresis, percussion, oral citrate, etc.) are described to enhance stone-free rate but are not widely accepted. Focused ultrasound-guided relocation of fragments is a recently described technique aimed at improving results of intervention for stone disease. Purpose of this review is to discuss development of this technology and its potential clinical applications. Pubmed search was made using key words "Focused ultrasound" and "kidney stone". All English language articles were reviewed by title. Relevant studies describing development and application of focused ultrasound in renal stones were selected for review. Focused ultrasound has proven its efficacy in successfully relocating up to 8 mm stone fragments in vitro and in pigs. Relocation is independent of stone composition. The latest model allows imaging and therapy with a single handheld probe facilitating its use by single operator. The acoustic energy delivered by the new prototype is even less than that used for extracorporeal shock wave lithotripsy. Therapeutic exposure has not caused thermal injury in pig kidneys. Focused ultrasound-guided relocation of stones is feasible. Though it is safe in application in pigs, technology is awaiting approval for clinical testing in human beings. This technology has many potential clinical applications in the management of stone disease.

  17. Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters

    DTIC Science & Technology

    2015-12-01

    1 AD_________________ AWARD NUMBER: W81XWH-08-2-0162 TITLE: Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War...Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters 5a. CONTRACT NUMBER 5b. GRANT NUMBER: W81XWH-08-2-0162 5c...Purpose: To demonstrate that 1) ultrasound guided foreign body removal (USFBR) is superior to conventional surgery in the cadaver model, 2) USFBR can be

  18. Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.

    PubMed

    Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J

    2010-09-01

    Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.

  19. Ultrasound guided transplantation of enriched and cryopreserved spermatogonial cell suspension in goats.

    PubMed

    Kaul, G; Kaur, J; Rafeeqi, T A

    2010-12-01

    Spermatogonial stem cells transplantation provides a unique approach for studying spermatogenesis. Initially developed in mice, this technique has now been extended in farm animals and provides an alternative means to preserve valuable male germ line and to produce transgenic animals. The aim of this study was to enrich type A spermatogonial cells amongst the isolated cells from goat testis, to cryopreserve these enriched populations of cells and their subsequent transplantation in unrelated recipient goats under ultrasound guidance. The cells were isolated enzymatically and enriched by differential plating and separation on discontinuous percoll gradient. Ultrasound guided injection of trypan blue dye into rete testis resulted in 20-30% filling of the seminiferous tubules. Prior to transplantation, the cells were labelled with a fluorescent dye to trace donor cells in recipient seminiferous tubules after transplantation. The fluorescent-labelled cells were observed up to 12 weeks after transplantation. © 2009 Blackwell Verlag GmbH.

  20. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    PubMed

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  1. Blind or ultrasound-guided corticosteroid injections and short-term response in subacromial impingement syndrome: a randomized, double-blind, prospective study.

    PubMed

    Dogu, Beril; Yucel, Serap Dalgic; Sag, Sinem Yamac; Bankaoglu, Mujdat; Kuran, Banu

    2012-08-01

    The aim of this study was to compare the accuracy of blind vs. ultrasonography-guided corticosteroid injections in subacromial impingement syndrome and determine the correlation between accuracy of the injection location and clinical outcome. Forty-six patients with subacromial impingement syndrome were randomized for ultrasonography-guided (group 1, n = 23) and blind corticosteroid injections (group 2, n = 23). Magnetic resonance imaging analysis was performed immediately after the injection. Changes in shoulder range of motion, pain, and shoulder function were recorded. All patients were assessed before the injection and 6 wks after the injection. Accurate injections were performed in 15 (65%) group 1 patients and in 16 (70%) group 2 patients. There was no statistically significant difference in the injection location accuracy between the two groups (P > 0.05). At the end of the sixth week, regardless of whether the injected mixture was found in the subacromial region or not, all of the patients showed improvements in all of the parameters evaluated (P < 0.05). Blind injections performed in the subacromial region by experienced individuals were reliably accurate and could therefore be given in daily routines. Corticosteroid injections in the subacromial region were very effective in improving the pain and functional status of patients with subacromial impingement syndrome during the short-term follow-up.

  2. Comparison of posterior internal anal sphincter myectomy and intrasphincteric botulinum toxin injection for treatment of internal anal sphincter achalasia: a meta-analysis.

    PubMed

    Friedmacher, Florian; Puri, Prem

    2012-08-01

    Internal anal sphincter (IAS) achalasia is a clinical condition with presentation similar to Hirschsprung's disease, but with the presence of ganglion cells on rectal suction biopsy (RSB). The diagnosis is made by anorectal manometry (ARM), which demonstrates the absence of the rectosphincteric reflex on rectal balloon inflation. The recommended treatment of choice is posterior IAS myectomy. Recently, intrasphincteric botulinum toxin (Botox) injection has been effectively used for treatment of IAS achalasia. The aim of this meta-analysis was to compare the efficacy of posterior IAS myectomy with intrasphincteric Botox injection for treatment of IAS achalasia. A systematic literature search for relevant articles was conducted using the following databases: MEDLINE( ® ), EMBASE(®), ISI Web of Science(SM) and the Cochrane Library. A meta-analysis was performed with the studies where IAS achalasia was diagnosed based on the results of ARM and RSB. Odds ratio (OR) with 95 % confidence intervals were calculated. Sixteen prospective and retrospective studies, published from 1973 to 2009, were identified. A total of 395 patients with IAS achalasia were included in this meta-analysis. Fifty-eight percent of patients underwent IAS myectomy and 42 % Botox injection. Regular bowel movements were significantly more frequent after IAS myectomy (OR 0.53, [95 % CI 0.29-0.99]; p = 0.04). There was no significant difference in continued use of laxatives or rectal enemas (OR 0.92, [95 % CI 0.34-2.53], p = 0.89) and in overall complication rates between both procedures (OR 0.68, [95 % CI 0.38-1.21]; p = 0.19). Looking at specific complications, the rate of transient faecal incontinence was significantly higher after Botox injection (OR 0.07, [95 % CI 0.01-0.54]; p < 0.01). Constipation and soiling were not significantly different between both procedures (OR 0.66, [95 % CI 0.30-1.48]; p = 0.31 and OR 0.24, [95 % CI 0.03-2.07]; p = 0.25). The rate of non

  3. Photoacoustic-guided ultrasound therapy with a dual-mode ultrasound array

    NASA Astrophysics Data System (ADS)

    Prost, Amaury; Funke, Arik; Tanter, Mickaël; Aubry, Jean-François; Bossy, Emmanuel

    2012-06-01

    Photoacoustics has recently been proposed as a potential method to guide and/or monitor therapy based on high-intensity focused ultrasound (HIFU). We experimentally demonstrate the creation of a HIFU lesion at the location of an optical absorber, by use of photoacoustic signals emitted by the absorber detected on a dual mode transducer array. To do so, a dedicated ultrasound array intended to both detect photoacoustic waves and emit HIFU with the same elements was used. Such a dual-mode array provides automatically coregistered reference frames for photoacoustic detection and HIFU emission, a highly desired feature for methods involving guidance or monitoring of HIFU by use of photoacoustics. The prototype is first characterized in terms of both photoacoustic and HIFU performances. The probe is then used to perform an idealized scenario of photoacoustic-guided therapy, where photoacoustic signals generated by an absorbing thread embedded in a piece of chicken breast are used to automatically refocus a HIFU beam with a time-reversal mirror and necrose the tissue at the location of the absorber.

  4. 3D ultrasound imaging in image-guided intervention.

    PubMed

    Fenster, Aaron; Bax, Jeff; Neshat, Hamid; Cool, Derek; Kakani, Nirmal; Romagnoli, Cesare

    2014-01-01

    Ultrasound imaging is used extensively in diagnosis and image-guidance for interventions of human diseases. However, conventional 2D ultrasound suffers from limitations since it can only provide 2D images of 3-dimensional structures in the body. Thus, measurement of organ size is variable, and guidance of interventions is limited, as the physician is required to mentally reconstruct the 3-dimensional anatomy using 2D views. Over the past 20 years, a number of 3-dimensional ultrasound imaging approaches have been developed. We have developed an approach that is based on a mechanical mechanism to move any conventional ultrasound transducer while 2D images are collected rapidly and reconstructed into a 3D image. In this presentation, 3D ultrasound imaging approaches will be described for use in image-guided interventions.

  5. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less

  6. Ultrasound-guided central venous access using Google Glass.

    PubMed

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Image-guided endobronchial ultrasound

    NASA Astrophysics Data System (ADS)

    Higgins, William E.; Zang, Xiaonan; Cheirsilp, Ronnarit; Byrnes, Patrick; Kuhlengel, Trevor; Bascom, Rebecca; Toth, Jennifer

    2016-03-01

    Endobronchial ultrasound (EBUS) is now recommended as a standard procedure for in vivo verification of extraluminal diagnostic sites during cancer-staging bronchoscopy. Yet, physicians vary considerably in their skills at using EBUS effectively. Regarding existing bronchoscopy guidance systems, studies have shown their effectiveness in the lung-cancer management process. With such a system, a patient's X-ray computed tomography (CT) scan is used to plan a procedure to regions of interest (ROIs). This plan is then used during follow-on guided bronchoscopy. Recent clinical guidelines for lung cancer, however, also dictate using positron emission tomography (PET) imaging for identifying suspicious ROIs and aiding in the cancer-staging process. While researchers have attempted to use guided bronchoscopy systems in tandem with PET imaging and EBUS, no true EBUS-centric guidance system exists. We now propose a full multimodal image-based methodology for guiding EBUS. The complete methodology involves two components: 1) a procedure planning protocol that gives bronchoscope movements appropriate for live EBUS positioning; and 2) a guidance strategy and associated system graphical user interface (GUI) designed for image-guided EBUS. We present results demonstrating the operation of the system.

  8. The Efficacy of Platelets Rich Plasma Injection in the Superior Joint Space of the Tempromandibular Joint Guided by Ultra Sound in Patients with Non-reducing Disk Displacement.

    PubMed

    Al-Delayme, Ra'ed M Ayoub; Alnuamy, Shefaa H; Hamid, Firas Taha; Azzamily, Tariq Jassim; Ismaeel, Salah AbdulMahdy; Sammir, R; Hadeel, M; Nabeel, Jafaar; Shwan, R; Alfalahi, Shahad Jamal; Yasin, Alaa

    2017-03-01

    The objective of this study was to determine average improvement during the rest and active mouth opening after ultrasound guided platelets rich plasma injection in the tempromandibular superior joint space for the patients complaining from non-reducing disk displacement. Thirty-four patients with non-reducing disk displacement underwent guided ultrasound injection of platelet rich plasma to the upper joint space. The extent of maximal mouth opening, chewing efficiency, sound intensity of the TMJ, and tenderness of the TMJ and the masticatory muscles at rest, motion and mastication were thoroughly assessed at the beginning of the study and scheduled for next follow-up at 1st, 3rd, and 6th months. Injection with platelets rich plasma was significantly more effective in improvements of the extent of maximal mouth opening, statistics result demonstrated a significant reduction in the VAS values of pain at rest, motion and mastication compared to the baseline VAS values. PRP injection to the upper temporomandibular joint space provided improvement in signs and symptoms of patient with non-reducing disk displacement of the temporomandibular joint.

  9. Interventional multispectral photoacoustic imaging with a clinical linear array ultrasound probe for guiding nerve blocks

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; West, Simeon J.; Nikitichev, Daniil I.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2016-03-01

    Accurate identification of tissue structures such as nerves and blood vessels is critically important for interventional procedures such as nerve blocks. Ultrasound imaging is widely used as a guidance modality to visualize anatomical structures in real-time. However, identification of nerves and small blood vessels can be very challenging, and accidental intra-neural or intra-vascular injections can result in significant complications. Multi-spectral photoacoustic imaging can provide high sensitivity and specificity for discriminating hemoglobin- and lipid-rich tissues. However, conventional surface-illumination-based photoacoustic systems suffer from limited sensitivity at large depths. In this study, for the first time, an interventional multispectral photoacoustic imaging (IMPA) system was used to image nerves in a swine model in vivo. Pulsed excitation light with wavelengths in the ranges of 750 - 900 nm and 1150 - 1300 nm was delivered inside the body through an optical fiber positioned within the cannula of an injection needle. Ultrasound waves were received at the tissue surface using a clinical linear array imaging probe. Co-registered B-mode ultrasound images were acquired using the same imaging probe. Nerve identification was performed using a combination of B-mode ultrasound imaging and electrical stimulation. Using a linear model, spectral-unmixing of the photoacoustic data was performed to provide image contrast for oxygenated and de-oxygenated hemoglobin, water and lipids. Good correspondence between a known nerve location and a lipid-rich region in the photoacoustic images was observed. The results indicate that IMPA is a promising modality for guiding nerve blocks and other interventional procedures. Challenges involved with clinical translation are discussed.

  10. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion PRINCIPAL...Sep 2014 - 28 Sep 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Guided Interventions for Prostate Cancer Using 3D- Transurethral Ultrasound and...Magnetic Resonance- Ultrasound (MR-US) fusion allows for specific targeting of the tumors in real-time during clinical interventions, outside of an MR

  11. Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.

    PubMed

    Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N

    2015-01-01

    The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.

  12. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    PubMed

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  14. Ultrasound-guided platelet-rich plasma injections for the treatment of common peroneal nerve palsy associated with multiple ligament injuries of the knee.

    PubMed

    Sánchez, M; Yoshioka, T; Ortega, M; Delgado, D; Anitua, E

    2014-05-01

    Peroneal nerve palsy in traumatic knee dislocations associated with multiple ligament injuries is common. Several surgical approaches are described for this lesion with less-than-optimal outcomes. The present case represents the application of plasma rich in growth factors (PRGF) technology for the treatment of peroneal nerve palsy with drop foot. This technology has already been proven its therapeutic potential for various musculoskeletal disorders. Based on these results, we hypothesized that PRGF could stimulate the healing process of traumatic peroneal nerve palsy with drop foot. The patient was a healthy 28-year-old man. He suffered peroneal nerve palsy with drop foot after multiple ligament injuries of the knee. PRGF was prepared according to the manufactured instruction. Eleven months after the trauma with severe axonotmesis, serial intraneural infiltrations of PRGF were started using ultrasound guidance. The therapeutic effect was assessed by electromyography (EMG), echogenicity of the peroneal nerve under ultrasound (US) and manual muscle testing. Twenty-one months after the first injection, not complete but partial useful recovery is obtained. He is satisfied with walking and running without orthosis. Sensitivity demonstrates almost full recovery in the peroneal nerve distribution area. EMG controls show complete reinnervation for the peroneus longus and a better reinnervation for the tibialis anterior muscle, compared with previous examinations. Plasma rich in growth factors (PRGF) infiltrations could enhance healing process of peroneal nerve palsy with drop foot. This case report demonstrates the therapeutic potential of this technology for traumatic peripheral nerve palsy and the usefulness of US-guided PRGF. V.

  15. Color Doppler Ultrasound and Gamma Imaging of Intratumorally Injected 500 nm Iron-Silica Nanoshells

    PubMed Central

    Liberman, Alexander; Wu, Zhe; Barback, Christopher V.; Viveros, Robert; Blair, Sarah L.; Ellies, Lesley G.; Vera, David R.; Mattrey, Robert F.; Kummel, Andrew C.; Trogler, William C.

    2013-01-01

    Perfluoropentane gas filled iron-silica nanoshells have been developed as stationary ultrasound contrast agents for marking tumors to guide surgical resection. It is critical to establish their long term imaging efficacy, as well as biodistribution. This work shows that 500 nm Fe-SiO2 nanoshells can be imaged by color Doppler ultrasound over the course of 10 days in Py8119 tumor bearing mice. The 500 nm non-biodegradable SiO2 and biodegradable Fe-SiO2 nanoshells were functionalized with diethylenetriamine pentaacetic acid (DTPA) ligand and radiolabeled with 111In3+ for biodistribution studies in nu/nu mice. The majority of radioactivity was detected in the liver and kidneys following intravenous (IV) administration of nanoshells to healthy animals. By contrast, after nanoshells were injected intratumorally, most of the radioactivity remained at the injection site; however, some nanoshells escaped into circulation and were distributed similarly as those given intravenously. For intratumoral delivery of nanoshells and IV delivery to healthy animals, little difference was seen between the biodistribution of SiO2 and biodegradable Fe-SiO2 nanoshells. However, when nanoshells were administered IV to tumor bearing mice, a significant increase was observed in liver accumulation of SiO2 nanoshells relative to biodegradable Fe-SiO2 nanoshells. Both SiO2 and Fe-SiO2 nanoshells accumulate passively in proportion to tumor mass, during intravenous delivery of nanoshells. This is the first report of the biodistribution following intratumoral injection of any biodegradable silica particle, as well as the first report demonstrating the utility of DTPA-111In labeling for studying silica nanoparticle biodistributions. PMID:23802554

  16. X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?

    PubMed Central

    Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas

    2017-01-01

    OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776

  17. Ultrasound guided platelet-rich plasma injection for the treatment of rotator cuff tendinopathy.

    PubMed

    Tahririan, Mohammad Ali; Moezi, Mehdi; Motififard, Mahdi; Nemati, Mahdi; Nemati, Amin

    2016-01-01

    Degenerative changes and inflammation in the rotator cuff (RC) are the most important causes of shoulder pain. The aim of the present study was to determine the effectiveness of platelet-rich plasma (PRP) in patients with chronic RC tendinopathy. This study was an open-label study performed at Kashani Hospital between April 2012 and June 2014. Patients with a <1 cm partial tearing of the bursal side of RC with no or little response to conservative management were included. PRP injection was done using ultrasonography guide via posterior subacromial approach. Demographic data were obtained in all patient before the study, and shoulder function was evaluated using Constant shoulder score (CSS) before and 3 months after PRP injection. A total number of 17 patients were enrolled. The mean of CSS before and after intervention was 37.05 ± 11.03 and 61.76 ± 14.75, respectively ( P < 0.001). There was no statistically significant correlation between the pain score before the study and the improvement in CSS ( P = 0.45, r = 0.03). Significant relation was observed between the individuals' age and improvement of CSS ( P = 0.02, r = -0.49). There was no significant difference in CSS improvement between genders ( P = 0.23). Single injection of PRP is effective to reduce pain and improve range of motion in patients with bursal side partial tearing of RC who failed to respond to conservative treatments.

  18. Magnetic resonance-guided motorized transcranial ultrasound system for blood-brain barrier permeabilization along arbitrary trajectories in rodents.

    PubMed

    Magnin, Rémi; Rabusseau, Fabien; Salabartan, Frédéric; Mériaux, Sébastien; Aubry, Jean-François; Le Bihan, Denis; Dumont, Erik; Larrat, Benoit

    2015-01-01

    Focused ultrasound combined with microbubble injection is capable of locally and transiently enhancing the permeability of the blood-brain barrier (BBB). Magnetic resonance imaging (MRI) guidance enables to plan, monitor, and characterize the BBB disruption. Being able to precisely and remotely control the permeabilization location is of great interest to perform reproducible drug delivery protocols. In this study, we developed an MR-guided motorized focused ultrasound (FUS) system allowing the transducer displacement within preclinical MRI scanners, coupled with real-time transfer and reconstruction of MRI images, to help ultrasound guidance. Capabilities of this new device to deliver large molecules to the brain on either single locations or along arbitrary trajectories were characterized in vivo on healthy rats and mice using 1.5 MHz ultrasound sonications combined with microbubble injection. The efficacy of BBB permeabilization was assessed by injecting a gadolinium-based MR contrast agent that does not cross the intact BBB. The compact motorized FUS system developed in this work fits into the 9-cm inner diameter of the gradient insert installed on our 7-T preclinical MRI scanners. MR images acquired after contrast agent injection confirmed that this device can be used to enhance BBB permeability along remotely controlled spatial trajectories of the FUS beam in both rats and mice. The two-axis motor stage enables reaching any region of interest in the rodent brain. The positioning error when targeting the same anatomical location on different animals was estimated to be smaller than 0.5 mm. Finally, this device was demonstrated to be useful for testing BBB opening at various acoustic pressures (0.2, 0.4, 0.7, and 0.9 MPa) in the same animal and during one single ultrasound session. Our system offers the unique possibility to move the transducer within a high magnetic field preclinical MRI scanner, thus enabling the delivery of large molecules to virtually

  19. American Medical Society for Sports Medicine (AMSSM) position statement: interventional musculoskeletal ultrasound in sports medicine.

    PubMed

    Finnoff, Jonathan T; Hall, Mederic M; Adams, Erik; Berkoff, David; Concoff, Andrew L; Dexter, William; Smith, Jay

    2015-02-01

    The use of diagnostic and interventional ultrasound has significantly increased over the past decade. A majority of the increased utilisation is by non-radiologists. In sports medicine, ultrasound is often used to guide interventions such as aspirations, diagnostic or therapeutic injections, tenotomies, releases and hydrodissections. Critically review the literature related to the accuracy, efficacy and cost-effectiveness of ultrasound-guided injections (USGIs) in major, intermediate and small joints; and soft tissues. Systematic review of the literature. USGIs are more accurate than landmark-guided injections (LMGIs; strength of recommendation taxonomy (SORT) Evidence Rating=A). USGIs are more efficacious than LMGIs (SORT Evidence Rating=B). USGIs are more cost-effective than LMGIs (SORT Evidence Rating=B). Ultrasound guidance is required to perform many new procedures (SORT Evidence Rating=C). The findings of this position statement indicate there is strong evidence that USGIs are more accurate than LMGI, moderate evidence that they are more efficacious and preliminary evidence that they are more cost-effective. Furthermore, ultrasound-guided (USG) is required to perform many new, advanced procedures and will likely enable the development of innovative USG surgical techniques in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Comparison of the therapeutic effects of ultrasound-guided platelet-rich plasma injection and dry needling in rotator cuff disease: a randomized controlled trial.

    PubMed

    Rha, Dong-wook; Park, Gi-Young; Kim, Yong-Kyun; Kim, Min Tae; Lee, Sang Chul

    2013-02-01

    To compare the effects of platelet-rich plasma injection with those of dry needling on shoulder pain and function in patients with rotator cuff disease. A single-centre, prospective, randomized, double-blinded, controlled study. University rehabilitation hospital. Thirty-nine patients with a supraspinatus tendon lesion (tendinosis or a partial tear less than 1.0 cm, but not a complete tear) who met the inclusion criteria recruited between June 2010 and February 2011. Two dry needling procedures in the control group and two platelet-rich plasma injections in the experimental group were applied to the affected shoulder at four-week intervals using ultrasound guidance. The Shoulder Pain and Disability Index, passive range of motion of the shoulder, a physician global rating scale at the six-month follow-up, adverse effects monitoring and an ultrasound measurement were used as outcome measures. The clinical effect of the platelet-rich plasma injection was superior to the dry needling from six weeks to six months after initial injection (P < 0.05). At six months the mean Shoulder Pain and Disability Index was 17.7 ± 3.7 in the platelet-rich plasma group versus 29.5 ± 3.8 in the dry needling group (P < 0.05). No severe adverse effects were observed in either group. Autologous platelet-rich plasma injections lead to a progressive reduction in the pain and disability when compared to dry needling. This benefit is certainly still present at six months after treatment. These findings suggest that treatment with platelet-rich plasma injections is safe and useful for rotator cuff disease.

  2. Sonographically guided deep plantar fascia injections: where does the injectate go?

    PubMed

    Maida, Eugene; Presley, James C; Murthy, Naveen; Pawlina, Wojciech; Smith, Jay

    2013-08-01

    To determine the distribution of sonographically guided deep plantar fascia injections in an unembalmed cadaveric model. A single experienced operator completed 10 sonographically guided deep plantar fascia injections in 10 unembalmed cadaveric specimens (5 right and 5 left) obtained from 6 donors (2 male and 4 female) aged 49 to 95 years (mean, 77.5 years) with a mean body mass index of 23.2 kg/m(2) (range, 18.4-26.3 kg/m(2)). A 12-3-MHz linear array transducer was used to direct a 22-gauge, 38-mm stainless steel needle deep to the plantar fascia at the anterior aspect of the calcaneus using an in-plane, medial-to-lateral approach. In each case, 1.5 mL of 50% diluted colored latex was injected deep to the plantar fascia. After a minimum of 72 hours, study coinvestigators dissected each specimen to assess injectate placement. All 10 injections accurately placed latex adjacent to the deep side of the plantar fascia at the anterior calcaneus. However, the flexor digitorum brevis (FDB) origin from the plantar fascia variably limited direct latex contact with the plantar fascia, and small amounts of latex interdigitated with the FDB origin in 90% (9 of 10). In all 10 specimens, latex also covered the traversing first branch of the lateral plantar nerve (FBLPN, ie, Baxter nerve) between the FDB and quadratus plantae muscles. No latex was found in the plantar fat pad or plantar fascia in any specimen. Sonographically guided deep plantar fascia injections reliably deliver latex deep to the plantar fascia while avoiding intrafascial injection. However, the extent of direct plantar fascia contact is variable due to the intervening FDB. On the contrary, the traversing FBLPN is reliably covered by the injection. Deep plantar fascia injections may have a role in the management of refractory plantar fasciitis, particularly following failed superficial perifascial or intrafascial injections, in cases of preferential deep plantar fascia involvement, or when entrapment

  3. MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics

    PubMed Central

    Napoli, Alessandro; Sacconi, Beatrice; Battista, Giuseppe; Guglielmi, Giuseppe; Catalano, Carlo; Albisinni, Ugo

    2016-01-01

    MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a “new” interventional technique and on its applications for MSK and allied sciences. PMID:26607640

  4. [Ultrasound-guided peripheral nerve block at wrist level for the treatment of idiopathic palmar hyperhidrosis with botulinum toxin].

    PubMed

    Olea, E; Fondarella, A; Sánchez, C; Iriarte, I; Almeida, M V; Martínez de Salinas, A

    2013-12-01

    Evaluation of pain and degree of satisfaction in patients undergoing ultrasound-assisted peripheral regional block for the treatment of idiopathic palmar hyperhidrosis with botulinum toxin. A descriptive, observational study of patients with palmar hyperhidrosis treated with botulinum toxin A, who underwent ultrasound-guided peripheral regional block of the median and ulnar nerves with 3 ml of mepivacaine 1% in each one. The radial nerve block was injected in the anatomical snuffbox. After establishing blocking, the dermatologist performed a mapping and injected around 100 IU of botulinum toxin across the whole palm. The pain experienced during the injection of botulinum toxin was evaluated by verbal numerical scale (from 0 to 10), along with the degree of satisfaction with the anesthetic technique, and the post-anesthetic complications. A total of 40 patients were enrolled in the study, 11 men and 29 women with no significant differences. The pain intensity assessed with verbal numerical scale was 1.03 (standard deviation of 1.37). No patients had a value greater than 5. The degree of patient satisfaction with the anesthetic technique was very good for 85% of the patients, and good for 7.5%. There were no complications related to type of anesthesia. The ultrasound-assisted peripheral regional block could be a simple, effective and safe technique for patients undergoing palmar injection of botulinum toxin. Pain intensity was very low, and it provided a very good level of satisfaction in most patients. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  5. High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy

    PubMed Central

    Copelan, Alexander; Hartman, Jason; Chehab, Monzer; Venkatesan, Aradhana M.

    2015-01-01

    Image-guided high-intensity focused ultrasound (HIFU) is an innovative therapeutic technology, permitting extracorporeal or endocavitary delivery of targeted thermal ablation while minimizing injury to the surrounding structures. While ultrasound-guided HIFU was the original image-guided system, MR-guided HIFU has many inherent advantages, including superior depiction of anatomic detail and superb real-time thermometry during thermoablation sessions, and it has recently demonstrated promising results in the treatment of both benign and malignant tumors. HIFU has been employed in the management of prostate cancer, hepatocellular carcinoma, uterine leiomyomas, and breast tumors, and has been associated with success in limited studies for palliative pain management in pancreatic cancer and bone tumors. Nonthermal HIFU bioeffects, including immune system modulation and targeted drug/gene therapy, are currently being explored in the preclinical realm, with an emphasis on leveraging these therapeutic effects in the care of the oncology patient. Although still in its early stages, the wide spectrum of therapeutic capabilities of HIFU offers great potential in the field of image-guided oncologic therapy. PMID:26622104

  6. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    PubMed

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  7. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.

  8. Ultrasound-guided greater occipital nerve blocks and pulsed radiofrequency ablation for diagnosis and treatment of occipital neuralgia.

    PubMed

    Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-09-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.

  9. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    PubMed Central

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778

  10. Cognitive task analysis for instruction in single-injection ultrasound guided-regional anesthesia

    NASA Astrophysics Data System (ADS)

    Gucev, Gligor V.

    Cognitive task analysis (CTA) is methodology for eliciting knowledge from subject matter experts. CTA has been used to capture the cognitive processes, decision-making, and judgments that underlie expert behaviors. A review of the literature revealed that CTA has not yet been used to capture the knowledge required to perform ultrasound guided regional anesthesia (UGRA). The purpose of this study was to utilize CTA to extract knowledge from UGRA experts and to determine whether instruction based on CTA of UGRA will produce results superior to the results of traditional training. This study adds to the knowledge base of CTA in being the first one to effectively capture the expert knowledge of UGRA. The derived protocol was used in a randomized, double blinded experiment involving UGRA instruction to 39 novice learners. The results of this study strongly support the hypothesis that CTA-based instruction in UGRA is more effective than conventional clinical instruction, as measured by conceptual pre- and post-tests, performance of a simulated UGRA procedure, and time necessary for the task performance. This study adds to the number of studies that have proven the superiority of CTA-informed instruction. Finally, it produced several validated instruments that can be used in instructing and evaluating UGRA.

  11. Ultrasound-Guided Regional Anesthesia Simulation Training: A Systematic Review.

    PubMed

    Chen, Xiao Xu; Trivedi, Vatsal; AlSaflan, AbdulHadi A; Todd, Suzanne Clare; Tricco, Andrea C; McCartney, Colin J L; Boet, Sylvain

    Ultrasound-guided regional anesthesia (UGRA) has become the criterion standard of regional anesthesia practice. Ultrasound-guided regional anesthesia teaching programs often use simulation, and guidelines have been published to help guide URGA education. This systematic review aimed to examine the effectiveness of simulation-based education for the acquisition and maintenance of competence in UGRA. Studies identified in MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and ERIC were included if they assessed simulation-based UGRA teaching with outcomes measured at Kirkpatrick level 2 (knowledge and skills), 3 (transfer of learning to the workplace), or 4 (patient outcomes). Two authors independently reviewed all identified references for eligibility, abstracted data, and appraised quality. After screening 176 citations and 45 full-text articles, 12 studies were included. Simulation-enhanced training improved knowledge acquisition (Kirkpatrick level 2) when compared with nonsimulation training. Seven studies measuring skill acquisition (Kirkpatrick level 2) found that simulation-enhanced UGRA training was significantly more effective than alternative teaching methods or no intervention. One study measuring transfer of learning into the clinical setting (Kirkpatrick level 3) found no difference between simulation-enhanced UGRA training and non-simulation-based training. However, this study was discontinued early because of technical challenges. Two studies examined patient outcomes (Kirkpatrick level 4), and one of these found that simulation-based UGRA training improved patient outcomes compared with didactic teaching. Ultrasound-guided regional anesthesia knowledge and skills significantly improved with simulation training. The acquired UGRA skills may be transferred to the clinical setting; however, further studies are required to confirm these changes translate to improved patient outcomes.

  12. Endoscopic ultrasound-guided transesophageal thoracentesis for minimal pleural effusion.

    PubMed

    Rana, Surinder Singh; Sharma, Ravi; Gupta, Rajesh

    2018-06-19

    Pleural effusion is a common finding both in patients with benign and malignant diseases of pleura and lung with diagnostic thoracentesis establishing the diagnosis in the majority of cases. The diagnostic thoracentesis can be done either blindly or under the guidance of ultrasound or computed tomography. However, minimal pleural effusion is difficult to sample even under image guidance. Endoscopic ultrasound (EUS) is known to detect smaller volume of pleural effusion and, thus, can help in guiding thoracentesis. To analyze the safety and efficacy of EUS-guided diagnostic thoracentesis in patients with undiagnosed minimal pleural effusion retrospectively. Retrospective analysis of the data of patients with minimal pleural effusion, who underwent EUS-guided transesophageal diagnostic thoracentesis over last 2 years, was performed. Thirteen patients (11 male; mean age 46.7 ± 16.2 years) with undiagnosed minimal pleural effusion underwent successful EUS-guided transesophageal diagnostic thoracentesis using a 22-G needle. Seven (53%) patients had fever on presentation whereas two presented with cough and loss of appetite. Eight to 54 mL fluid was aspirated with an attempt to completely empty the pleural cavity. There were no complications of the procedure. EUS-guided diagnostic thoracentesis is a safe and effective alternative for evaluating patients with minimal pleural effusion.

  13. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  14. Simulation and training of ultrasound supported anaesthesia: a low-cost approach

    NASA Astrophysics Data System (ADS)

    Schaaf, T.; Lamontain, M.; Hilpert, J.; Schilling, F.; Tolxdorff, T.

    2010-03-01

    The use of ultrasound imaging technology during techniques of peripheral nerve blockade offers several clinical benefits. Here we report on a new method to educate residents in ultrasound-guided regional anesthesia. The daily challenge for the anesthesiologists is the 3D angle-depending handling of the stimulation needle and the ultrasound probe while watching the 2D ultrasound image on the monitor. Purpose: Our approach describes how a computer-aided simulation and training set for ultrasound-guided regional anesthesia could be built based on wireless low-cost devices and an interactive simulation of a 2D ultrasound image. For training purposes the injection needle and the ultrasound probe are replaced by wireless Bluetooth-connected 3D tracking devices, which are embedded in WII-mote controllers (Nintendo-Brand). In correlation to the tracked 3D positions of the needle and transducer models the visibility and position of the needle should be simulated in the 2D generated ultrasound image. Conclusion: In future, this tracking and visualization software module could be integrated in a more complex training set, where complex injection paths could be trained based on a 3D segmented model and the training results could be part of a curricular e-learning module.

  15. 'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.

    PubMed

    Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao

    2015-04-01

    The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.

  16. Single, double or multiple-injection techniques for non-ultrasound guided axillary brachial plexus block in adults undergoing surgery of the lower arm.

    PubMed

    Chin, Ki Jinn; Alakkad, Husni; Cubillos, Javier E

    2013-08-08

    Regional anaesthesia comprising axillary block of the brachial plexus is a common anaesthetic technique for distal upper limb surgery. This is an update of a review first published in 2006 and updated in 2011. To compare the relative effects (benefits and harms) of three injection techniques (single, double and multiple) of axillary block of the brachial plexus for distal upper extremity surgery. We considered these effects primarily in terms of anaesthetic effectiveness; the complication rate (neurological and vascular); and pain and discomfort caused by performance of the block. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), MEDLINE, EMBASE and reference lists of trials. We contacted trial authors. The date of the last search was March 2013 (updated from March 2011). We included randomized controlled trials that compared double with single-injection techniques, multiple with single-injection techniques, or multiple with double-injection techniques for axillary block in adults undergoing surgery of the distal upper limb. We excluded trials using ultrasound-guided techniques. Independent study selection, risk of bias assessment and data extraction were performed by at least two investigators. We undertook meta-analysis. The 21 included trials involved a total of 2148 participants who received regional anaesthesia for hand, wrist, forearm or elbow surgery. Risk of bias assessment indicated that trial design and conduct were generally adequate; the most common areas of weakness were in blinding and allocation concealment.Eight trials comparing double versus single injections showed a statistically significant decrease in primary anaesthesia failure (risk ratio (RR 0.51), 95% confidence interval (CI) 0.30 to 0.85). Subgroup analysis by method of nerve location showed that the effect size was greater when neurostimulation was used rather than the transarterial technique.Eight trials comparing multiple with single

  17. Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.

    PubMed

    Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason

    2017-05-01

    To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.

  18. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  19. The Rectal Administration of Lignocaine Gel and Periprostatic Lignocaine Infiltration During Transrectal Ultrasound-Guided Prostate Biopsy Provides Effective Analgesia

    PubMed Central

    Siddiqui, EJ; Ali, S; Koneru, S

    2006-01-01

    INTRODUCTION Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or exclude prostate cancer. This procedure can be associated with significant discomfort, both on insertion of the ultrasound probe as well as on taking the biopsy. We evaluated a new technique for pain relief during TRUS biopsy. PATIENTS AND METHODS In Group 1 (n = 60), the biopsies were taken without any analgesia. In Group 2 (n = 60), 11 ml of Instillagel (2% lignocaine) was administered rectally prior to probe insertion and 5 ml of 1% lignocaine periprostatic injection was administered before taking the biopsy. The discomfort encountered during the procedure was graded by the patient on a scale ranging from no discomfort to mild, moderate and severe pain. RESULTS In Group 2, there was a marked reduction in the pain experienced during the procedure. The Chi-squared test for trend showed a significant association between the rectal administration of local anaesthetic gel and reduction in pain on probe insertion (P = 0.0001). There was also a significant association between the use of periprostatic lignocaine injection and reduction in pain on taking the biopsy (P < 0.0001). CONCLUSIONS The use of lignocaine gel prior to probe insertion and periprostatic infiltration of lignocaine before taking the needle biopsy significantly reduces the pain experienced by the patient during TRUS-guided prostate biopsy. PMID:16551424

  20. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  1. Needle placement for piriformis injection using 3-D imaging.

    PubMed

    Clendenen, Steven R; Candler, Shawn A; Osborne, Michael D; Palmer, Scott C; Duench, Stephanie; Glynn, Laura; Ghazi, Salim M

    2013-01-01

    Piriformis syndrome is a pain syndrome originating in the buttock and is attributed to 6% - 8% of patients referred for the treatment of back and leg pain. The treatment for piriformis syndrome using fluoroscopy, computed tomography (CT), electromyography (EMG), and ultrasound (US) has become standard practice. The treatment of Piriformis Syndrome has evolved to include fluoroscopy and EMG with CT guidance. We present a case study of 5 successful piriformis injections using 3-D computer-assisted electromagnet needle tracking coupled with ultrasound. A 6-degree of freedom electromagnetic position tracker was attached to the ultrasound probe that allowed the system to detect the position and orientation of the probe in the magnetic field. The tracked ultrasound probe was used to find the posterior superior iliac spine. Subsequently, 3 points were captured to register the ultrasound image with the CT or magnetic resonance image scan. Moreover, after the registration was obtained, the navigation system visualized the tracked needle relative to the CT scan in real-time using 2 orthogonal multi-planar reconstructions centered at the tracked needle tip. Conversely, a recent study revealed that fluoroscopically guided injections had 30% accuracy compared to ultrasound guided injections, which tripled the accuracy percentage. This novel technique exhibited an accurate needle guidance injection precision of 98% while advancing to the piriformis muscle and avoiding the sciatic nerve. The mean (± SD) procedure time was 19.08 (± 4.9) minutes. This technique allows for electromagnetic instrument tip tracking with real-time 3-D guidance to the selected target. As with any new technique, a learning curve is expected; however, this technique could offer an alternative, minimizing radiation exposure.

  2. In-line positioning of ultrasound images using wireless remote display system with tablet computer facilitates ultrasound-guided radial artery catheterization.

    PubMed

    Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo

    2016-02-01

    Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.

  3. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    PubMed

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays

    DTIC Science & Technology

    2001-10-25

    81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased

  5. Treatment of isolated mediastinal and hilar recurrence of lung cancer with bronchoscopic endobronchial ultrasound guided intratumoral injection of chemotherapy with cisplatin.

    PubMed

    Mehta, Hiren J; Begnaud, Abbie; Penley, Andrea M; Wynne, John; Malhotra, Paras; Fernandez-Bussy, Sebastian; Cope, Jessica M; Shuster, Jonathan J; Jantz, Michael A

    2015-12-01

    A common pattern of recurrence in lung cancer after receiving full dose external beam radiation therapy (EBRT) to targeted sites is isolated mediastinal and hilar recurrence (IMHR). Treatment options for these patients are limited to palliative radiation, chemotherapy, and/or best supportive care. We describe our experience with treating IMHR with bronchoscopic endobronchial ultrasound (EBUS) guided intratumoral injection of cisplatin (ITC). Patients treated between Jan 2009-September 2014 with ITC for IMHR were included. Patient demographics, tumor histology, size, concurrent therapy, location, number of sites treated, treatment sessions, and encounters were abstracted. Responses were analyzed on follow-up scans 8-12 weeks after the last treatment session using RECIST 1.1 criteria. Locoregional recurrence, progression-free survival (PFS), and overall survival were measured. 50 sites were treated in 36 patients (19 males, 17 females) with mean age 61.9±8.5 years. Eight sites treated on subsequent encounters were excluded and one patient had an unevaluable response, leaving 35 patients and 41 sites for final analysis. 24/35 (69%) had complete or partial response (responders), whereas 11/35 (31%) had stable or progressive disease (non-responders). There were no significant differences in response based on histology, size, and concurrent therapy. Median survival for the group was 8 months (95% CI of 6-11 mo). Responders had significantly higher survival and PFS than non-responders. Two patients treated with concurrent EBRT, developed broncho-mediastinal fistula. EBUS guided intratumoral cisplatin for IMHR appears to be safe and effective, and may represent a new treatment paradigm for this patient population. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Botox Injections

    MedlinePlus

    ... Contact Us Shopping Cart American Academy of Facial Plastic and Reconstructive Surgery Home Meetings & Courses Find a ... FAQ's For Patients Procedures What is a Facial Plastic Surgeon Facelift Surgery Wrinkle Treatment Lip Enhancement Nose ...

  7. [Ultrasound-guided rectus sheath block for upper abdominal surgery].

    PubMed

    Osaka, Yoshimune; Kashiwagi, Masanori; Nagatsuka, Yukio; Oosaku, Masayoshi; Hirose, Chikako

    2010-08-01

    Upper abdominal surgery leads to severe postoperative pain. Insufficient postoperative analgesia accompanies a high incidence of complications. Therefore, postoperative analgesia is very important. The epidural analgesia has many advantages. However it has a high risk of epidural hematoma in anticoagulated patients. Rectus sheath block provided safer and more reliable analgesia in recent years, by the development of ultrasound tools. We experienced two cases of the rectus sheath block in upper abdominal surgery under ultrasound guidance. Ultrasound guided rectus sheath block can reduce the risk of peritoneal puncture, bleeding, and other complications. Rectus sheath block is very effective to reduce postoperative pain in upper abdominal surgery as an alternative method to epidural anesthesia in anticoagulated patients.

  8. CLINICAL EVALUATION OF THE RAPID ACCESS VITREAL INJECTION GUIDE: A Handheld Instrument for Assisting Intravitreal Injections.

    PubMed

    Han, Dennis P; McKenney, Kaitlin C; Kim, Judy E; Weinberg, David V; Musch, David C; Singh, Ravi S J

    2017-04-01

    The Rapid Access Vitreal Injection (RAVI) guide combines the function of an eyelid speculum and measuring caliper into a single instrument for assisting intravitreal injections. This study clinically evaluated the RAVI guide with respect to patient acceptance, complication rates, and operative goals. A prospective study was performed on 54 patients undergoing intravitreal injections using the RAVI guide (n = 32) or the speculum/caliper (n = 22). Device-related pain was assessed using the Wong-Baker scoring system, scaled from 0 (no pain) to 10 (agonizing pain). Mean device-related pain score did not differ significantly between the 2 groups, with scores of 0.6 and 0.7 for the RAVI guide and speculum groups, respectively. The rate of significant pain (score of ≥2) was twice as high in the speculum group (7 of 22, 32%) compared with the RAVI guide group (5 of 32, 16%), but this difference was not statistically significant (P = 0.19, Fisher's exact test). Operative goals of avoiding needle touch to lashes/lids and guiding needle insertion to the intended site were achieved in all patients. The RAVI guide appeared equivalent to the eyelid speculum in achieving operative goals, with similarly low pain scores. It has the potential for facilitating efficient, accurate, and safe intravitreal injections.

  9. Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

    PubMed

    Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J

    2006-01-01

    Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.

  10. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  11. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    NASA Astrophysics Data System (ADS)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  12. Teaching medical students ultrasound-guided vascular access - which learning method is best?

    PubMed

    Lian, Alwin; Rippey, James C R; Carr, Peter J

    2017-05-15

    Ultrasound is recommended to guide insertion of peripheral intravenous vascular cannulae (PIVC) where difficulty is experienced. Ultrasound machines are now common-place and junior doctors are often expected to be able to use them. The educational standards for this skill are highly varied, ranging from no education, to self-guided internet-based education, to formal, face-to-face traditional education. In an attempt to decide which educational technique our institution should introduce, a small pilot trial comparing educational techniques was designed. Thirty medical students were enrolled and allocated to one of three groups. PIVC placing ability was then observed, tested and graded on vascular access phantoms. The formal, face-to-face traditional education was rated best by the students, and had the highest success rate in PIVC placement, the improvement statistically significant compared to no education (p = 0.01) and trending towards significance when compared to self-directed internet-based education (p<0.06). The group receiving traditional face-to-face teaching on ultrasound-guided vascular access, performed significantly better than those not receiving education. As the number of ultrasound machines in clinical areas increases, it is important that education programs to support their safe and appropriate use are developed.

  13. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    NASA Astrophysics Data System (ADS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-07-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.

  14. A cMUT probe for ultrasound-guided focused ultrasound targeted therapy.

    PubMed

    Gross, Dominique; Coutier, Caroline; Legros, Mathieu; Bouakaz, Ayache; Certon, Dominique

    2015-06-01

    Ultrasound-mediated targeted therapy represents a promising strategy in the arsenal of modern therapy. Capacitive micromachined ultrasonic transducer (cMUT) technology could overcome some difficulties encountered by traditional piezoelectric transducers. In this study, we report on the design, fabrication, and characterization of an ultrasound-guided focused ultrasound (USgFUS) cMUT probe dedicated to preclinical evaluation of targeted therapy (hyperthermia, thermosensitive liposomes activation, and sonoporation) at low frequency (1 MHz) with simultaneous ultrasonic imaging and guidance (15 to 20 MHz). The probe embeds two types of cMUT arrays to perform the modalities of targeted therapy and imaging respectively. The wafer-bonding process flow employed for the manufacturing of the cMUTs is reported. One of its main features is the possibility of implementing two different gap heights on the same wafer. All the design and characterization steps of the devices are described and discussed, starting from the array design up to the first in vitro measurements: optical (microscopy) and electrical (impedance) measurements, arrays' electroacoustic responses, focused pressure field mapping (maximum peak-to-peak pressure = 2.5 MPa), and the first B-scan image of a wire-target phantom.

  15. Ultrasound-Guided Cryoanalgesia of Peripheral Nerve Lesions.

    PubMed

    Djebbar, Sahlya; Rossi, Ignacio M; Adler, Ronald S

    2016-11-01

    The real-time nature of ultrasound makes it ideally suited to provide guidance for a variety of musculoskeletal interventional procedures involving peripheral nerves. Continuous observation of the needle ensures proper placement and allows continuous monitoring when performing localized ablative therapy and therefore more accurate positioning of a cryoprobe, use of smaller needles, as well as access to small structures. We describe our experience performing cryoablative procedures. Patients undergoing cryoneurolysis have largely reported varying degrees of long-term pain relief and improvement in function; no serious complications have yet been identified. Ultrasound-guided cryoneurolysis can provide a useful, safe alternative to other ablative techniques to achieve long-term analgesia from painful peripheral nerve lesions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Utility of ultrasound-guided injection of botulinum toxin type A for muscle imbalance in children with obstetric brachial plexus palsy: Description of the procedure and action protocol.

    PubMed

    García Ron, A; Gallardo, R; Huete Hernani, B

    2017-03-24

    Obstetric brachial plexus palsy (OBPP) usually has a favourable prognosis. However, nearly one third of all severe cases have permanent sequelae causing a high level of disability. In this study, we explore the effectiveness of ultrasound-guided injection of botulinum toxin A (BoNT-A) and describe the procedure. We designed a prospective, descriptive study including patients with moderate to severe OBPP who were treated between January 2010 and December 2014. We gathered demographic data, type of OBPP, and progression. Treatment effectiveness was assessed with the Active Movement Scale (AMS), the Mallet classification, and video recordings. We gathered a total of 14 133 newborns, 15 of whom had OBPP (1.6 per 1000 live births). Forty percent of the cases had severe OBPP (0.4/1000), a dystocic delivery, and APGAR scores < 5; mean weight was 4038g. Mean age at treatment onset was 11.5 months. The muscles most frequently receiving BoNT-A injections were the pronator teres, subscapularis, teres major, latissimus dorsi, and pectoralis major. All the patients who completed the follow-up period (83%) experienced progressive improvements: up to 3 points on the AMS and a mean score of 19.5 points out of 25 on the Mallet classification at 2 years. Treatment improved muscle function and abnormal posture in all cases. Surgery was avoided in 3 patients and delayed in one. Adverse events were mild and self-limited. Due to its safety and effectiveness, BoNT-A may be used off-label as an adjuvant to physical therapy and/or surgery in moderate to severe OBPP. Ultrasound may increase effectiveness and reduce adverse effects. Copyright © 2017 The Authors. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Transcranial MR-Guided Focused Ultrasound: A Review of the Technology and Neuro Applications

    PubMed Central

    Ghanouni, Pejman; Pauly, Kim Butts; Elias, W. Jeff; Henderson, Jaimie; Sheehan, Jason; Monteith, Stephen; Wintermark, Max

    2015-01-01

    MR guided focused ultrasound is a new, minimally invasive method of targeted tissue thermal ablation that may be of use to treat central neuropathic pain, essential tremor, Parkinson tremor, and brain tumors. The system has also been used to temporarily disrupt the blood-brain barrier to allow targeted drug delivery to brain tumors. This article reviews the physical principles of MR guided focused ultrasound and discusses current and potential applications of this exciting technology. PMID:26102394

  18. Ultrasound-mediated gene delivery of naked plasmid DNA in skeletal muscles: a case for bolus injections.

    PubMed

    Sanches, Pedro Gomes; Mühlmeister, Mareike; Seip, Ralf; Kaijzel, Eric; Löwik, Clemens; Böhmer, Marcel; Tiemann, Klaus; Grüll, Holger

    2014-12-10

    Localized gene delivery has many potential clinical applications. However, the nucleic acids (e.g. pDNA and siRNA) are incapable of passively crossing the endothelium, cell membranes and other biological barriers which must be crossed to reach their intracellular targets. A possible solution is the use of ultrasound to burst circulating microbubbles inducing transient permeabilization of surrounding tissues which mediates nucleic acid extravasation and cellular uptake. In this study we report on an optimization of the ultrasound gene delivery technique. Naked pDNA (200 μg) encoding luciferase and SonoVue® microbubbles were co-injected intravenously in mice. The hindlimb skeletal muscles were exposed to ultrasound from a non-focused transducer (1 MHz, 1.25 MPa, PRI 30s) and injection protocols and total amounts as well as ultrasound parameters were systemically varied. Gene expression was quantified relative to a control using a bioluminescence camera system at day 7 after sonication. Bioluminescence ratios in sonicated/control muscles of up to 101× were obtained. In conclusion, we were able to specifically deliver genetic material to the selected skeletal muscles and overall, the use of bolus injections and high microbubble numbers resulted in increased gene expression reflected by stronger bioluminescence signals. Based on our data, bolus injections seem to be required in order to achieve transient highly concentrated levels of nucleic acids and microbubbles at the tissue of interest which upon ultrasound exposure should lead to increased levels of gene delivery. Thus, ultrasound mediated gene delivery is a promising technique for the clinical translation of localized drug delivery. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Ultrasound-Guided Vascular Access Simulator for Medical Training: Proposal of a Simple, Economic and Effective Model.

    PubMed

    Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio

    2017-03-01

    To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.

  20. Brief reports: regional anesthesia needles can introduce ultrasound gel into tissues.

    PubMed

    Belavy, David

    2010-09-01

    Anesthesiologists may insert needles through ultrasound gel when performing ultrasound-guided regional anesthesia. In this study, it was determined whether needles carry gel into tissues. Ultrasound gel dyed blue was applied to pork rashers. Tuohy and short-bevel needles were passed through the gel and pork. The needles were then assessed for the presence of ultrasound gel. All needles, including those with stylets, carried gel and tissue within the lumen. Ultrasound gel may be injected around (and perhaps in) nerves during regional anesthesia procedures. Studies are needed to determine the implications of this practice.

  1. A multimodal image guiding system for Navigated Ultrasound Bronchoscopy (EBUS): A human feasibility study

    PubMed Central

    Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav

    2017-01-01

    Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758

  2. Sonographically guided posteromedial approach for intra-articular knee injections: a safe, accurate, and efficient method.

    PubMed

    Tresley, Jonathan; Jose, Jean

    2015-04-01

    Osteoarthritis of the knee can be a debilitating and extremely painful condition. In patients who desire to postpone knee arthroplasty or in those who are not surgical candidates, percutaneous knee injection therapies have the potential to reduce pain and swelling, maintain joint mobility, and minimize disability. Published studies cite poor accuracy of intra-articular knee joint injections without imaging guidance. We present a sonographically guided posteromedial approach to intra-articular knee joint injections with 100% accuracy and no complications in a consecutive series of 67 patients undergoing subsequent computed tomographic or magnetic resonance arthrography. Although many other standard approaches are available, a posteromedial intra-articular technique is particularly useful in patients with a large body habitus and theoretically allows for simultaneous aspiration of Baker cysts with a single sterile preparation and without changing the patient's position. The posteromedial technique described in this paper is not compared or deemed superior to other standard approaches but, rather, is presented as a potentially safe and efficient alternative. © 2015 by the American Institute of Ultrasound in Medicine.

  3. A Randomized Double-Blinded Trial on the Effects of Ultrasound Transducer Orientation on Teaching and Learning Ultrasound-Guided Regional Anesthesia.

    PubMed

    Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R

    2016-07-01

    Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.

  4. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advancedmore » techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.« less

  5. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  6. Transvaginal ultrasound-guided embryo transfer in IVF.

    PubMed

    Larue, L; Keromnes, G; Massari, A; Roche, C; Moulin, J; Gronier, H; Bouret, D; Cassuto, N G; Ayel, J P

    2017-05-01

    To determine whether transvaginal ultrasound-guided embryo transfer is a technique that can be used routinely, whether it improves IVF outcomes and whether it makes difficult transfers easier and more successful. Non-randomized retrospective study conducted between 2012 and 2016 in the fertility center of the Diaconesses-Croix St-Simon hospital group. The outcomes of 3910 transfers, performed by 5 senior operators, under transabdominal ultrasound guidance are compared with those of 800 transfers, performed by 1 senior operator under transvaginal ultrasound guidance. The criteria studied are the feasibility of the technique and the percentage of pregnancies per transfer in the two populations described, as well as in the difficult and very difficult transfer populations. All the transfers were feasible under transvaginal ultrasound guidance without the use of forceps or additional instruments. The percentage of pregnancies per transfer is significantly increased, when the transfer is performed under transvaginal ultrasound guidance compared with that performed under transabdominal ultrasound guidance, in the general population (38%, n=800 vs 30%, n=3910; P 0.0004) and in the reference population characterized by age <38 years and >6 oocytes collected per puncture (45%, n=490 vs 36%, n=1968; P 0.002). The percentage of pregnancies per transfer (P/T) is not significantly different in the populations of easy transfers (n 695, 38% P/T), difficult transfers (n 58, 46% P/T; P=ns) and very difficult transfers (n 47, 34% P/T; P=ns). Embryo transfer is a key stage in IVF, in which the quality of performance determines the outcome. In this study, transvaginal ultrasound guidance of the transfer, which is the reference procedure in gynaecological imaging, significantly increases the percentage of pregnancies per transfer, both in the general population and in the reference population, compared with transfers performed under transabdominal ultrasound guidance. Transvaginal

  7. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  8. Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.

    PubMed

    Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu

    2015-11-01

    Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.

  9. Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe

    PubMed Central

    Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.

    2014-01-01

    Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628

  10. Botulinum toxin B: the new option in cosmetic injection.

    PubMed

    Spencer, James M

    2002-07-01

    Botulinum toxin, one of nature's most toxic substances, is the unlikely source of one of cosmetic dermatology's most popular new injectable treatment options. This article describes the physiological and biological workings of the several structurally similar but antigenically distinct serotypes of botulinum toxin, and provides clinical studies comparing and contrasting the key ingredients in Botox, Dysport, and Myobloc (Neurobloc).

  11. Ultrasound-Guided Foot and Ankle Procedures.

    PubMed

    Henning, P Troy

    2016-08-01

    This article reviews commonly performed injections about the foot and ankle region. Although not exhaustive in its description of available techniques, general approaches to these procedures are applicable to any injection about the foot and ankle. As much as possible, the procedures described are based on commonly used or published techniques. An in-depth knowledge of the regional anatomy and understanding of different approaches when performing ultrasonography-guided procedures allows clinicians to adapt to any clinical scenario. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    PubMed

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  13. Switch to Abobotulinum toxin A may be useful in the treatment of neurogenic detrusor overactivity when intradetrusor injections of Onabotulinum toxin A failed.

    PubMed

    Bottet, Florie; Peyronnet, Benoit; Boissier, Romain; Reiss, Bénédicte; Previnaire, Jean G; Manunta, Andrea; Kerdraon, Jacques; Ruffion, Alain; Lenormand, Loïc; Perrouin Verbe, Brigitte; Gaillet, Sarah; Gamé, Xavier; Karsenty, Gilles

    2018-01-01

    To assess the outcomes of switching to a different brand of botulinum toxin A (BTA, from Botox® to Dysport®) in case of failure of intradetrusor injections (IDI) of Botox® in the treatment of neurogenic detrusor overactivity (NDO). The charts of all patients who underwent a switch to IDI of Dysport® after failure of an IDI of Botox® at six departments of neurourology were retrospectively reviewed. The main outcomes of interest were the bladder diary data and four urodynamic parameters: maximum cystometric capacity (MCC), maximum detrusor pressure (PDET max), and volume at first uninhibited detrusor contraction (UDC). Fifty-seven patients were included. After the first injection of Dysport®, no adverse events were reported. A significant decrease in number of urinary incontinence episodes per day was observed in 52.63% of patients (P < 0.001) and all patients experienced a reduction in PDET Max (-8.1 cmH20 on average; P = 0.003). MCC significantly increased by a mean of 41.2 (P = 0.02). The proportion of patients with no UDC increased significantly at week 6 after ATA injections (from 15.79% to 43.9%; P = 0.0002). Hence, 32 patients draw clinical and/or urodynamic benefits from the botulinum toxin switch from (56.14%). After a median follow up of 21 months, 87% of responders to BTA switch were still treated successfully with BTA. Most patients refractory to Botox® (56.14%) draw benefits from the switch to Dysport®. © 2017 Wiley Periodicals, Inc.

  14. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    PubMed

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  15. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients

    PubMed Central

    Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-01-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173

  16. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    PubMed

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  17. Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP.

    PubMed

    Mora Soler, Ana María; Álvarez Delgado, Alberto; Piñero Pérez, María Concepción; Velasco-Guardado, Antonio; Marcos Prieto, Héctor; Rodríguez Pérez, Antonio

    2018-05-01

    endoscopic ultrasound-guided biliary drainage (EUS-BD) is an alternative to percutaneous trans-hepatic biliary drainage (PTBD) in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). this is a retrospective description of six cases of endoscopic ultrasound-guided biliary drainage via choledochoduodenostomy (EUCD), as well as the clinical characteristics, endoscopic procedure, complications and monitoring. all cases had malignant distal biliary obstruction. The procedure was concluded with good drainage in four out of six patients. Two late complications were recorded that were caused by stent migration and there were no deaths related with the procedure. The average monitoring period was six months. EUCD can be considered as a valid therapeutic choice in some selected cases and when performed by a team of expert endoscopists in cases of failed ERCP drainage or as an alternative to PTBD. However, the procedure has some associated complications.

  18. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    PubMed

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p < 0.0001). When the thickness was greater or equal to 9.9 cm, drained volume was always more than 1000 ml. The measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  19. Assessing the effectiveness of botulinum toxin injections for adductor spasmodic dysphonia: clinician and patient perception.

    PubMed

    Braden, Maia N; Johns, Michael M; Klein, Adam M; Delgaudio, John M; Gilman, Marina; Hapner, Edie R

    2010-03-01

    To determine the effectiveness of Botox treatment for adductor spasmodic dysphonia (ADSD), the clinician and patient judge changes in voice symptoms and the effect on quality of life. Currently, there is no standard protocol for determining the effectiveness of Botox injections in treating ADSD. Therefore, clinicians use a variety of perceptual scales and patient-based self-assessments to determine patients' impressions of severity and changes after treatments. The purpose of this study was to assess clinician-patient agreement of the effects of Botox on voice quality and quality of life in ADSD. Retrospective chart review of 199 randomly selected patients since 2004. Results indicated a weak correlation between the patient's assessment of voice impairment (EIS) and patient's quality of life impairment (Voice-Related Quality of Life [V-RQOL]) in the mild-moderate dysphonia severity group and the moderate-to-severe dysphonia group. There was a weak correlation between the patient's assessment of voice impairment EIS and the clinician's perceptual judgment of voice impairment (Consensus Auditory Perceptual Evaluation of Voice [CAPE-V]) only in the moderate to severe dysphonia group. There was a weak correlation between the patient's quality of life impairment (V-RQOL) and the clinician's perceptual judgment of voice impairment (CAPE-V) only in the severe to profound dysphonia group. The poor relationship among commonly used outcome measures leads us to question how best to assess the effectiveness of Botox in ADSD. Clinicians are required to document treatment outcomes, making it important to use scales that are valid, reliable, and sensitive to change. Future research directions include examining relationships between measures both before and after Botox injections, examining the specific factors that determine quality of life changes, and further research on specific parameters of the CAPE-V as well as comparing perceptual and quality of life scales with acoustic

  20. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    PubMed

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  1. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    PubMed

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  2. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    DTIC Science & Technology

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine (Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine (Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US

  3. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of

  4. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning.

    PubMed

    Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A

    2014-08-01

    To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Botulinum Toxin A Injections Into Pelvic Floor Muscles Under Electromyographic Guidance for Women With Refractory High-Tone Pelvic Floor Dysfunction: A 6-Month Prospective Pilot Study.

    PubMed

    Morrissey, Darlene; El-Khawand, Dominique; Ginzburg, Natasha; Wehbe, Salim; O'Hare, Peter; Whitmore, Kristene

    2015-01-01

    High-tone pelvic floor dysfunction (HTPFD) is a debilitating chronic pain disorder for many women with significant impact on their quality of life (QoL). Our objective was to determine the efficacy of electromyography-guided onabotulinumtoxinA (Botox; Allergan, Irvine, Calif) injections in treating patient's perception of pelvic pain and improving QoL measurement scores. This is a prospective pilot open-label study of women with chronic pelvic pain and HTPFD who have failed conventional therapy between January 2011 and August 2013. Botox injections (up to 300 U) were done using needle electromyography guidance, from a transperineal approach, to localize spastic pelvic floor muscles (PFMs). Data were collected at baseline, 4, 8, 12, and 24 weeks after injections. This included demographics; Visual Analog Scale (VAS) scores for pain and dyspareunia; validated questionnaires for symptoms, QoL, and sexual function; Global Response Assessment scale for pelvic pain; digital examination of PFM for tone and tenderness; and vaginal manometry. Side effects were also recorded. Out of 28 women who enrolled in the study, 21 completed the 6-month follow-up and qualified for analysis. The mean (SD) age was 35.1 (9.4) years (range, 22-50 years), and the mean (SD) body mass index was 25 (4.4). Comorbidities included interstitial cystitis/bladder pain syndrome (42.9%) and vulvodynia (66.7%). Overall, 61.9% of subjects reported improvement on Global Response Assessment at 4 weeks and 80.9% at 8, 12, and 24 weeks post injection, compared with baseline. Of the subjects who were sexually active at baseline, 58.8% (10/17), 68.8% (11/16), 80% (12/15), and 83.3% (15/18) reported less dyspareunia at 4, 8, 12, and 24 weeks, respectively. Dyspareunia Visual Analog Scale score significantly improved at weeks 12 (5.6, P = 0.011) and 24 (5.4, P = 0.004) compared with baseline (7.8). Two of the 4 patients who avoided sexual activity at baseline secondary to dyspareunia resumed and tolerated

  6. A comparative trial of ice application versus EMLA cream in alleviation of pain during botulinum toxin injections for palmar hyperhidrosis.

    PubMed

    Alsantali, Adel

    2018-01-01

    Botulinum toxin is a safe and effective therapy for palmar hyperhidrosis, but the associated pain from injections limits the usefulness of this method of treatment. To evaluate the efficacy of Eutectic Mixture of Local Anesthetics (EMLA) cream versus ice application in alleviation of pain during botulinum toxin injections for palmar hyperhidrosis. In this prospective study, 23 patients underwent palm Botox injections to treat their excessive sweating. In each patient, EMLA cream was applied to one palm and ice was applied directly before the injections in the other palm. Pain was evaluated using a Visual Analog Scale. Statistically, there was a significant difference in pain control between EMLA cream group and ice application group ( p <0.05). The average pain score on the hands where EMLA cream was applied was 8.9 (SD=0.81), whereas it was 4.8 (±0.9) in the ice group. In this study, the successful use of ice application in reducing pain by 40% in comparison to EMLA cream during Botox toxin injection for palmar hyperhidrosis is demonstrated.

  7. A comparative trial of ice application versus EMLA cream in alleviation of pain during botulinum toxin injections for palmar hyperhidrosis

    PubMed Central

    Alsantali, Adel

    2018-01-01

    Background Botulinum toxin is a safe and effective therapy for palmar hyperhidrosis, but the associated pain from injections limits the usefulness of this method of treatment. Purpose To evaluate the efficacy of Eutectic Mixture of Local Anesthetics (EMLA) cream versus ice application in alleviation of pain during botulinum toxin injections for palmar hyperhidrosis. Methods In this prospective study, 23 patients underwent palm Botox injections to treat their excessive sweating. In each patient, EMLA cream was applied to one palm and ice was applied directly before the injections in the other palm. Pain was evaluated using a Visual Analog Scale. Results Statistically, there was a significant difference in pain control between EMLA cream group and ice application group (p<0.05). The average pain score on the hands where EMLA cream was applied was 8.9 (SD=0.81), whereas it was 4.8 (±0.9) in the ice group. Conclusion In this study, the successful use of ice application in reducing pain by 40% in comparison to EMLA cream during Botox toxin injection for palmar hyperhidrosis is demonstrated. PMID:29662322

  8. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Osteoid Osteoma: A Case Series Report.

    PubMed

    Rovella, Marcello S; Martins, Guilherme L P; Cavalcanti, Conrado F A; Bor-Seng-Shu, Edson; Camargo, Olavo P; Cerri, Giovanni G; Menezes, Marcos R

    2016-04-01

    Osteoid osteoma is painful benign tumor. The aim of this study was to report our initial experience using magnetic resonance-guided focused ultrasound to treat osteoid osteomas. This retrospective single-center study included four patients treated with magnetic resonance-guided focused ultrasound. They presented with severe pain with reduced quality of life and a poor response to clinical treatment. The pre- and post-treatment evaluation comprised computed tomography and magnetic resonance imaging and focused on quality of life and the impact of pain on daily activities. After treatment, three patients had complete pain resolution with no recurrence. One patient had a recurrence of symptoms after 2 wk and underwent a new successful treatment with increased energy levels. On average, 13 sonications were administered (8-18 sonications/treatment) with an average energy of 2,003 J (range: 1,063-3,522 J). Magnetic resonance-guided focused ultrasound appears to be a feasible, tolerable and effective treatment in selected patients with osteoid osteomas. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Ultrasound - Breast

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...

  10. Safety of ultrasound-guided high-intensity focused ultrasound ablation for diffuse adenomyosis: A retrospective cohort study.

    PubMed

    Feng, Yujie; Hu, Liang; Chen, Wenzhi; Zhang, Rong; Wang, Xi; Chen, Jinyun

    2017-05-01

    To evaluate the safety of ultrasound-guided high-intensity focused ultrasound (HIFU) ablation for patients with diffuse adenomyosis. This was a retrospective cohort study. The data was collected from 417 symptomatic adenomyosis patients who underwent ultrasound-guided HIFU between January 2012 and December 2015 at 1st Affiliated Hospital of Chongqing Medical University, Chongqing, China. Among them were 260 patients with diffuse adenomyosis (Group D) and 157 patients with focal adenomyosis (Group F). All patients underwent contrast-enhanced magnetic resonance imaging (MRI) one week before and the day after HIFU treatment. Successful treatment with HIFU was measured by the non-perfused volume ratio (NPVR). Intraprocedural and postprocedural adverse effects and complications were recorded to assess the safety of the procedure. Patients were followed-up for three months post-treatment. Complications were given a grade A through F according to the SIR Standards. All patients successfully completed the procedure, non-perfused regions appeared in 415 (99.5%) patients. The non-perfused volume ratio (NPVR) of Group D was significantly lower than that of Group F (P<0.05). During the procedure, the odds ratio of skin-burning pain was 1.7 (OR=1.617, 95% CI: 1.103-2.532), when comparing Group D with Group F, while the odds ratio of inguinal pain was equal to 2.0 (OR=2.038, 95% CI: 1.161-3.580), when Group F was compared to Group D. 97 patients (23.3%) received nominal therapy due to complications ([Society of interventional radiology, SIR]-B grade), among them, there were 62 cases (23.8%) in Group D and 35 cases (22.3%) in Group F. No significant difference was found between the two groups (P>0.05) and neither of the reported complications of SIR-C-SIR-F occurred within the two groups. Based on our results, ultrasound-guided HIFU is safe for the treatment of diffuse adenomyosis, and controlling the ablation zone is crucial to ensure patients' safety. Copyright © 2016 Elsevier

  11. A novel ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  12. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algin, Oktay, E-mail: droktayalgin@gmail.com; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-02-15

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improvedmore » clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.« less

  13. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.

    PubMed

    Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki

    2017-03-01

    The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    PubMed

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  15. An ultrasound-guided fluorescence tomography system: design and specification

    NASA Astrophysics Data System (ADS)

    D'Souza, Alisha V.; Flynn, Brendan P.; Kanick, Stephen C.; Torosean, Sason; Davis, Scott C.; Maytin, Edward V.; Hasan, Tayyaba; Pogue, Brian W.

    2013-03-01

    An ultrasound-guided fluorescence molecular tomography system is under development for in vivo quantification of Protoporphyrin IX (PpIX) during Aminolevulinic Acid - Photodynamic Therapy (ALA-PDT) of Basal Cell Carcinoma. The system is designed to combine fiber-based spectral sampling of PPIX fluorescence emission with co-registered ultrasound images to quantify local fluorophore concentration. A single white light source is used to provide an estimate of the bulk optical properties of tissue. Optical data is obtained by sequential illumination of a 633nm laser source at 4 linear locations with parallel detection at 5 locations interspersed between the sources. Tissue regions from segmented ultrasound images, optical boundary data, white light-informed optical properties and diffusion theory are used to estimate the fluorophore concentration in these regions. Our system and methods allow interrogation of both superficial and deep tissue locations up to PpIX concentrations of 0.025ug/ml.

  16. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial)

    PubMed Central

    2011-01-01

    Background Breast-conserving surgery for breast cancer was developed as a method to preserve healthy breast tissue, thereby improving cosmetic outcomes. Thus far, the primary aim of breast-conserving surgery has been the achievement of tumour-free resection margins and prevention of local recurrence, whereas the cosmetic outcome has been considered less important. Large studies have reported poor cosmetic outcomes in 20-40% of patients after breast-conserving surgery, with the volume of the resected breast tissue being the major determinant. There is clear evidence for the efficacy of ultrasonography in the resection of nonpalpable tumours. Surgical resection of palpable breast cancer is performed with guidance by intra-operative palpation. These palpation-guided excisions often result in an unnecessarily wide resection of adjacent healthy breast tissue, while the rate of tumour-involved resection margins is still high. It is hypothesised that the use of intra-operative ultrasonography in the excision of palpable breast cancer will improve the ability to spare healthy breast tissue while maintaining or even improving the oncological margin status. The aim of this study is to compare ultrasound-guided surgery for palpable tumours with the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumour-free margins, cosmetic outcomes and quality of life. Methods/design In this prospective multicentre randomised controlled clinical trial, 120 women who have been diagnosed with palpable early-stage (T1-2N0-1) primary invasive breast cancer and deemed suitable for breast-conserving surgery will be randomised between ultrasound-guided surgery and palpation-guided surgery. With this sample size, an expected 20% reduction of resected breast tissue and an 18% difference in tumour-free margins can be detected with a power of 80%. Secondary endpoints include cosmetic outcomes and quality of life. The rationale, study

  17. Magnetic resonance guided high-intensity focused ultrasound ablation of musculoskeletal tumors

    PubMed Central

    Avedian, Raffi S.; Gold, Garry; Ghanouni, Pejman; Pauly, Kim Butts

    2015-01-01

    This article reviews the fundamental principles and clinical experimental uses of magnetic resonance guided high-intensity focused ultrasound (MRgHIFU) ablation of musculoskeletal tumors. MRgHIFU is a noninvasive treatment modality that takes advantage of the ability of magnetic resonance to measure tissue temperature and uses this technology to guide high-intensity focused ultrasound waves to a specific focus within the human body that results in heat generation and complete thermal necrosis of the targeted tissue. Adjacent normal tissues are spared because of the accurate delivery of thermal energy, as well as, local blood perfusion that provides a cooling effect. MRgHIFU is approved by the Food and Drug Administration for the treatment of uterine fibroids and is used on an experimental basis to treat breast, prostate, liver, bone, and brain tumors. PMID:26120376

  18. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated

  19. Combined Ultrasound and MR Imaging to Guide Focused Ultrasound Therapies in the Brain

    PubMed Central

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-01-01

    Purpose Several emerging therapies with potential for use in the brain harness effects produced by acoustic cavitation – the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength, and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. Materials and Methods We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. Results The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. Conclusion While preliminary, these data clearly demonstrate, for the first time, that is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate it will also prove to

  20. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    NASA Astrophysics Data System (ADS)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  1. Novel ultrasound-responsive chitosan/perfluorohexane nanodroplets for image-guided smart delivery of an anticancer agent: Curcumin.

    PubMed

    Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid

    2017-05-01

    Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. A review of randomised controlled trials comparing ultrasound-guided foam sclerotherapy with endothermal ablation for the treatment of great saphenous varicose veins.

    PubMed

    Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W

    2016-05-01

    The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author

  3. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    PubMed

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7 < 2.6, 1.6 < 4.0, 3.5 < 5.8, 3.6 < 5.2, 3.2 < 4.2, 1.3 < 2.0), and a higher patient satisfaction score at 6, 12, 18, 24, and 36 h post-operatively than group 2 (7.8 > 6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p < 0.001), and the mean size of rebound pain was smaller in group 1 than that in group 2 (2.5 > 4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier

  4. Sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region

    PubMed Central

    Karmakar, M K; Li, X; Kwok, W H; Ho, A M-H; Ngan Kee, W D

    2012-01-01

    Objectives The use of ultrasound to guide peripheral nerve blocks is now a well-established technique in regional anaesthesia. However, despite reports of ultrasound guided epidural access via the paramedian approach, there are limited data on the use of ultrasound for central neuraxial blocks, which may be due to a poor understanding of spinal sonoanatomy. The aim of this study was to define the sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach. Methods The sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach was defined using a “water-based spine phantom”, young volunteers and anatomical slices rendered from the Visible Human Project data set. Results The water-based spine phantom was a simple model to study the sonoanatomy of the osseous elements of the lumbar spine. Each osseous element of the lumbar spine, in the spine phantom, produced a “signature pattern” on the paramedian sagittal scans, which was comparable to its sonographic appearance in vivo. In the volunteers, despite the narrow acoustic window, the ultrasound visibility of the neuraxial structures at the L3/L4 and L4/L5 lumbar intervertebral spaces was good, and we were able to delineate the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach. Conclusion Using a simple water-based spine phantom, volunteer scans and anatomical slices from the Visible Human Project (cadaver) we have described the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region. PMID:22010025

  5. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  6. Sonothrombolysis of Intra-Catheter Aged Venous Thrombi Using Microbubble Enhancement and Guided Three Dimensional Ultrasound Pulses

    PubMed Central

    Kutty, Shelby; Xie, Feng; Gao, Shunji; Drvol, Lucas K; Lof, John; Fletcher, Scott E; Radio, Stanley J; Danford, David A; Hammel, James M; Porter, Thomas R

    2010-01-01

    Central venous and arterial catheters are a major source of thrombo-embolic disease in children. We hypothesized that guided high mechanical index (MI) impulses from diagnostic three-dimensional (3D) ultrasound during an intravenous microbubble infusion could dissolve these thrombi. An in vitro system simulating intra-catheter thrombi was created and then treated with guided high MI impulses from 3D ultrasound, utilizing low MI microbubble sensitive imaging pulse sequence schemes to detect the microbubbles (Perflutren Lipid Microsphere, Definity®, Lantheus). Ten aged thrombi over 24 hours old were tested using 3D ultrasound coupled with a continuous diluted microbubble infusion (Group A), and ten with 3D ultrasound alone (Group B). Mean thrombus age was 28.6 hours (range 26.6–30.3). Groups A exhibited a 55 ± 19 % reduction in venous thrombus size, compared to 31±10 % for Group B (p=0.008). Feasibility testing was performed in 4 pigs, establishing a model to further investigate the efficacy. Sonothrombolysis of aged intra-catheter venous thrombi can be achieved with commercially available microbubbles and guided high MI ultrasound from a diagnostic 3D transducer. PMID:20696549

  7. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    PubMed

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  8. Ultrasound-guided subacromial injections of sodium hyaluronate for the management of rotator cuff tendinopathy: a prospective comparative study with rehabilitation therapy.

    PubMed

    Merolla, G; Bianchi, P; Porcellini, G

    2013-06-01

    Rotator cuff (RC) tendinopathy is a common cause of pain and shoulder dysfunction. The literature evidence suggests that a combination of overuse and extrinsic compression may induce chronic RC tendinopathy. Aim of the current study was to compare the results of subacromial sodium hyaluronate injections with rehabilitation therapy. We enrolled 48 patients (M/F: 26/22; mean age: 50 years; shoulder right/left: 29/19) with persistent shoulder pain for at least 4 months. Exclusion criteria were as follows: RC tear, calcifying tendinitis, glenohumeral instability, osteoarthritis, rheumatic diseases, physical therapy and/or injection in the previous 4 months, shoulder surgery, anesthetic nerve block, trauma, and severe medical diseases. The included subjects received either two ultrasound-guided subacromial hyaluronic acid (HA) injections (25 patients, HA group) at baseline and 14 days, or underwent rehabilitation therapy (23 patients, Physio group) including active shoulder mobilization, soft tissue stretching and humeral head positioner and propeller muscles strengthening for 30 days (3 sessions every week). Clinical assessment of shoulder function was performed with visual analog scale score for pain (0-100), Oxford Shoulder Score (OSS), and Constant-Murley Score (CS). Overall, patients were examined at baseline, week 2, week 4, week 12, and week 24. Statistical significance was set at 5 % (p < 0.05). Reduction in overall pain in the HA group was statistically significant at week 2 (p < 0.05) week 4 (p < 0.05), week 12 comparing to baseline. Similarly, pain subscores (at night and with activity) were significantly lower at week 2 (p < 0.05), week 4 (p < 0.05), and week 12 (p < 0.05), respectively. In the Physio group, pain decreased significantly at week 2 (p < 0.05) but not maintained at week 4 (p > 0.05), week 12 (p > 0.05), and week 24 (p > 0.05). CS and OSS in the HA group increased significantly at week 2 (p < 0.05), week 4 (p < 0

  9. Ultrasound-guided medical thoracoscopy in the absence of pleural effusion.

    PubMed

    Marchetti, Giampietro; Valsecchi, Alberto; Indellicati, Davide; Arondi, Sabrina; Trigiani, Marco; Pinelli, Valentina

    2015-04-01

    Medical thoracoscopy (MT) is a diagnostic and therapeutic procedure that permits the study of the pleural space. The presence of pleural adhesions is the most important contraindication to performing MT. Lesions of the pleura in absence of pleural effusion are usually studied in video-assisted thoracoscopic surgery (VATS) with preoperative ultrasound evaluation. No data are available about ultrasound-guided MT in the absence of pleural effusion. From January 2007 to June 2013, 622 consecutive MTs were performed under ultrasound guidance without inducing a pneumothorax. A retrospective cohort of 29 patients affected by pleural diseases without fluid was reviewed. The fifth or sixth intercostal spaces along the midaxillary line with a good echographic "sliding sign" and normal appearance of the pleural line were chosen as the entry site. The pleural cavity was explored, and biopsies were performed. The mean age of the patient cohort was 62.8 years; there were 20 male patients and nine female patients. Pleural adherences were avoided, and adequate number of pleural biopsies were performed. No parenchymal lung injuries, bleeding, or hematoma occurred. Seventeen patients had a completely free pleural cavity, four patients had a single pleural adhesion, and eight had multiple pleural adhesions; in all cases, however, endoscopic exploration was possible and biopsy specimens were adequate. The most frequent histopathologic diagnosis was malignant pleural mesothelioma. We have shown that thoracic ultrasound accurately identifies intrathoracic adhesions and, in experienced hands, can guide MT access, replacing the VATS approach, even in the complete absence of pleural effusion.

  10. Propogation loss with frequency of ultrasound guided waves in a composite metal-honeycomb structure

    NASA Astrophysics Data System (ADS)

    Saxena, Indu F.; Baid, Harsh K.; Guzman, Narciso; Kempen, Lothar U.; Mal, Ajit

    2009-05-01

    Non-destructive testing of critical structural components is time consuming, while necessary for maintaining safe operation. Large aerospace structures, such as the vertical stabilizers of aircraft undergo inspection at regular intervals for damage diagnostics. However, conventional techniques for damage detection and identification before repair can be scheduled are conducted off-line and therefore can take weeks. The use of guided ultrasound waves is being investigated to expedite damage detection in composites. We measure the frequency dependent loss of ultrasonic guided waves for a structure comprising a boron-nitride composite skin sandwiching an aluminum honeycomb. A wide range of ultrasound frequencies propagate as measured using PZTs, with the lowest attenuation observed about 200-250 kHz. These measurements are confirmed using optical fiber Bragg grating arrays used as ultrasound transducers.

  11. MR-guided focused ultrasound robot for performing experiments on large animals

    NASA Astrophysics Data System (ADS)

    Mylonas, N.; Damianou, C.

    2011-09-01

    Introduction: In this paper an experimental MRI-guided focused ultrasound robot for large animals is presented. Materials and methods: A single element spherically focused transducer of 4 cm diameter, focusing at 10 cm and operating at 1 MHz was used. A positioning device was developed in order to scan the ultrasound transducer for performing MR-guided focused ultrasound experiments in large animals such as pig, sheep and dog. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, Acrylonitrile Butadiene Styrene (ABS) plastic, brass screws, and brass pulleys. The system is manufactured automatically using a rapid prototyping system. Results: The system was tested successfully in a number of animals for various tasks (creation of single lesions, creation of overlapping lesions, and MR compatibility). Conclusions: A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can be via a lateral or superior-inferior approach. This system has the potential to be marketed as a cost effective solution for performing experiments in small and large animals.

  12. Ultrasound-guided percutaneous tracheostomy in critically ill obese patients

    PubMed Central

    2012-01-01

    Introduction The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Methods Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m2. The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). Results The median BMIs were 34 kg/m2 (32-38) in the obese patient group and 25 kg/m2 (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. Conclusions This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. Trial registration ClinicalTrials.gov: NCT01502657. PMID:22390815

  13. Ultrasound-guided percutaneous tracheostomy in critically ill obese patients.

    PubMed

    Guinot, Pierre-Grégoire; Zogheib, Elie; Petiot, Sandra; Marienne, Jean-Pierre; Guerin, Anne-Marie; Monet, Pauline; Zaatar, Rody; Dupont, Hervé

    2012-12-12

    The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m². The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). The median BMIs were 34 kg/m² (32-38) in the obese patient group and 25 kg/m² (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. ClinicalTrials.gov: NCT01502657.

  14. New platform for evaluating ultrasound-guided interventional technologies

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.

    2016-04-01

    Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.

  15. Therapeutic aspects of endoscopic ultrasound

    NASA Astrophysics Data System (ADS)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  16. Robotic active positioning for magnetic resonance-guided high-intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Xiao, Xu; Huang, Zhihong; Volovick, Alexander; Melzer, Andreas

    2012-11-01

    Magnetic resonance (MR) guided High-intensity focused ultrasound (HIFU) is a noninvasive method producing thermal necrosis and cavitation at the position of tumors with high accuracy. Because the typical size of the high-intensity focused ultrasound focus are much smaller than the targeted tumor or other tissues, multiple sonications and focus repositioning become necessary for HIFU treatment. In order to reach a much wider range, manual repositioning or using MR compatible mechanical actuators could be used. The repositioning technique is a time consuming procedure because it needs a series of MR imaging to detect the transducer and markers preplaced on the mechanical devices. We combined an active tracking technique into the MR guided HIFU system. In this work, the robotic system used is the MR-compatible robotics from InnoMotion{trade mark, serif} (IBSMM, Engineering spol. s r.o. / Ltd, Czech) which is originally designed for MR-guided needle biopsy. The precision and positioning speed of the combined robotic HIFU system are evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the HIFU treatment to operate in a larger spatial range and with a faster speed.

  17. Guiding tissue regeneration with ultrasound in vitro and in vivo

    NASA Astrophysics Data System (ADS)

    Dalecki, Diane; Comeau, Eric S.; Raeman, Carol H.; Child, Sally Z.; Hobbs, Laura; Hocking, Denise C.

    2015-05-01

    Developing new technologies that enable the repair or replacement of injured or diseased tissues is a major focus of regenerative medicine. This paper will discuss three ultrasound technologies under development in our laboratories to guide tissue regeneration both in vitro and in vivo. A critical obstacle in tissue engineering is the need for rapid and effective tissue vascularization strategies. To address this challenge, we are developing acoustic patterning techniques for microvascular tissue engineering. Acoustic radiation forces associated with ultrasound standing wave fields provide a rapid, non-invasive approach to spatially pattern cells in three dimensions without affecting cell viability. Acoustic patterning of endothelial cells leads to the rapid formation of microvascular networks throughout the volumes of three-dimensional hydrogels, and the morphology of the resultant microvessel networks can be controlled by design of the ultrasound field. A second technology under development uses ultrasound to noninvasively control the microstructure of collagen fibers within engineered tissues. The microstructure of extracellular matrix proteins provides signals that direct cell functions critical to tissue regeneration. Thus, controlling collagen microfiber structure with ultrasound provides a noninvasive approach to regulate the mechanical properties of biomaterials and control cellular responses. The third technology employs therapeutic ultrasound to enhance the healing of chronic wounds. Recent studies demonstrate increased granulation tissue thickness and collagen deposition in murine dermal wounds exposed to pulsed ultrasound. In summary, ultrasound technologies offer noninvasive approaches to control cell behaviors and extracellular matrix organization and thus hold great promise to advance tissue regeneration in vitro and in vivo.

  18. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    NASA Astrophysics Data System (ADS)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  19. Comparison of ultrasound-guided supraclavicular block according to the various volumes of local anesthetic

    PubMed Central

    Kim, Seok Kon; Kang, Bong Jin; Kwon, Min A; Song, Jae Gyok; Jeon, Soo Mi

    2013-01-01

    Background The ultrasound guidance in regional nerve blocks has recently been introduced and gaining popularity. Ultrasound-guided supraclavicular block has many advantages including the higher success rate, faster onset time, and fewer complications. The aim of this study was to examine the clinical data according to the varied volume of local anesthetics in the ultrasound-guided supraclavicular block. Methods One hundred twenty patients were randomized into four groups, according to the local anesthetic volume used: Group 35 (n = 30), Group 30 (n = 30), Group 25 (n = 30), and Group 20 (n = 30). Supraclavicular blocks were performed with 1% mepivacaine 35 ml, 30 ml, 25 ml, and 20 ml, respectively. The success rate, onset time, and complications were checked and evaluated. Results The success rate (66.7%) was lower in Group 20 than that of Group 35 (96.7%) (P < 0.05). The average onset times of Group 35, Group 30, Group 25, and Group 20 were 14.3 ± 6.9 min, 13.6 ± 4.5 min, 16.7 ± 4.6 min, and 16.5 ± 3.7 min, respectively. There were no significant differences. Horner's syndrome was higher in Group 35 (P < 0.05). Conclusions In conclusion, we achieved 90% success rate with 30 ml of 1% mepivacaine. Therefore, we suggest 30 ml of local anesthetic volume for ultrasound-guided supraclavicular block. PMID:23814648

  20. Effectiveness and safety of CEUS-guided haemostatic injection for blunt splenic trauma: an animal experiment.

    PubMed

    Li, W; Tang, J; Lv, F; Zhang, H; Zhang, S; An, L

    2010-10-01

    The aim of this study was to investigate whether complications occur after haemostatic agents are injected into blunt splenic injuries. After undergoing ultrasound (US), contrast-enhanced US (CEUS) and contrast-enhanced computed tomography (CECT) examinations, dogs with grade III-IV injury received the minimally invasive therapy. After treatment, CEUS was performed to observe changes in the regions treated. In the immediate group, dogs underwent laparotomy 30 min after treatment to observe the haemostatic effect. In the survival group, animals underwent CEUS and CECT examinations to observe the short-term healing outcome and complications at 3, 7, 14, and 21 days after the injection. After undergoing CEUS and CECT examinations, 12 dogs with grade III-IV injury received the minimally invasive therapy. Before injection, CEUS examinations showed anechoic and/or hypoechoic perfusion defects and active bleeding at the injury sites, and CECT showed traumatic lesions as low-density regions without enhancement. After treatment, CEUS demonstrated the disappearance of active bleeding, and hyperechoic spots emerged at the injury sites. Uneven density regions were displayed on CECT. Treated areas were covered by blood clots and glue membrane in the immediate-group animals. Three weeks later, CEUS showed a decrease of hyperechoic spots in the survival group, and the splenic parenchyma enhanced uniformly on CECT. Laparotomy showed that the greater omentum had moved upwards and partly covered the wound in four animals, and the injury sites had completely healed. Histopathological examination showed that fibrous connective tissue covered the splenic capsule and that the haemostatic glue had degraded. No complication occurred, such as delayed splenic haemorrhage, splenic abscesses, splenic pseudoaneurysms, intestinal obstruction or intestinal adhesions. CEUS-guided haemostatic injection is not only effective in stopping active bleeding immediately, but it is also safe in that no

  1. Cognitive Task Analysis for Instruction in Single-Injection Ultrasound Guided-Regional Anesthesia

    ERIC Educational Resources Information Center

    Gucev, Gligor V.

    2012-01-01

    Cognitive task analysis (CTA) is methodology for eliciting knowledge from subject matter experts. CTA has been used to capture the cognitive processes, decision-making, and judgments that underlie expert behaviors. A review of the literature revealed that CTA has not yet been used to capture the knowledge required to perform ultrasound guided…

  2. Obstructive parotitis secondary to an acute masseteric bend.

    PubMed

    Reddy, Ryan; White, David R; Gillespie, M Boyd

    2012-01-01

    To investigate 3 cases of chronic parotitis secondary to an acute bend in Stensen's duct caused by an enlargement of the masseteric space. Three female patients presented with symptoms consistent with obstructive parotitis including glandular swelling and tenderness during meals. A 10-year-old patient had unilateral facial swelling with enlargement of the masseter muscle and mandible later diagnosed as fibrous dysplasia. Salivary endoscopy showed an acute bend in Stensen's duct secondary to a mass effect. The patient's parotid swelling resolved following debulking of the mandibular mass and sialendoscopy with irrigation. Two adult patients with bilateral parotid involvement presented with bilateral masseteric hypertrophy and dental wear facets consistent with bruxism. Salivary endoscopy revealed bilateral kinking of Stensen's duct with jaw closure. Both patients improved symptomatically following nightly bite guard use and ultrasound-guided Botox injections of the masseter muscle and parotid. Obstructive parotitis is rarely caused by an acute masseteric bend. Diagnosis of a kinking Stensen's duct is aided with salivary endoscopy and imaging to determine the precipitating pathology. In the case of masseteric hypertrophy, symptomatic improvement can be achieved with Botox-induced atrophy of masseteric hypertrophy or with surgical reduction for associated fibrous dysplasia. Copyright © 2011 S. Karger AG, Basel.

  3. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2018-06-01

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  4. Laparoscopic Heller myotomy provides durable relief from achalasia and salvages failures after botox or dilation.

    PubMed

    Rosemurgy, Alexander; Villadolid, Desiree; Thometz, Donald; Kalipersad, Candice; Rakita, Steven; Albrink, Michael; Johnson, Milton; Boyce, Worth

    2005-05-01

    To report outcome after laparoscopic Heller myotomy in a large number of patients. Laparoscopic Heller myotomy has been undertaken for over a decade, but most studies involve small numbers of patients with limited follow-up. Since 1992, 262 patients have undergone laparoscopic Heller myotomy and been prospectively followed. Concomitant fundoplication was undertaken for a patulous hiatus or large hiatal hernia or to buttress the repair of an esophagotomy until recently when it became routinely applied. With mean follow-up at 32 months, symptoms were scored by patients on a Likert scale (frequency: 0 = Never to 10 = Every time I eat/always; severity: 0 = Not bothersome to 10 = Very bothersome). Before myotomy, 79% received Botox or bag dilation: 52% had Botox, 59% underwent dilation, and 36% had both. Inadvertent esophagotomy occurred in 5%. Concomitant diverticulectomy was undertaken in 4%, and fundoplication was undertaken in 30%. Complications were infrequent. Median length of stay was 1 day. After myotomy, the frequency and severity of symptoms of achalasia and reflux significantly decreased. Eighty-eight percent of patients felt their symptoms were greatly improved or resolved, and 90% felt their outcome was satisfying or better. Ninety-three percent felt they would undergo myotomy again, if necessary. Laparoscopic Heller myotomy can safely and durably relieve symptoms of dysphagia while also reducing symptoms of reflux. Length of stay is short and patient satisfaction is very high with extended follow-up. Laparoscopic Heller myotomy is strongly encouraged for patients with symptomatic achalasia and is efficacious even after failures of dilation and/or Botox therapy.

  5. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  6. Reproducibility of Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Thermal Lesions in Minimally-Invasive Brain Surgery

    NASA Astrophysics Data System (ADS)

    Zahedi, Sulmaz

    This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.

  7. The story of Clostridium botulinum: from food poisoning to Botox.

    PubMed

    Ting, Patricia T; Freiman, Anatoli

    2004-01-01

    In the last fifty years, Clostridium botulinum has become notorious for its ability to produce the deadly botulinum neurotoxins. While botulinum toxin A, better known as Botox, is universally recognised by the public as a cosmetic enhancement tool, the botulinum neurotoxins are commonly used off-label for many medical conditions in ophthalmology, neurology and dermatology. The versatility of these botulinum toxins has made Clostridium botulinum one of the most widely known bacterial pathogens in medical history. This article outlines the discovery of botulinum toxins through to their present day applications in medicine.

  8. Transvaginal 3D Image-Guided High Intensity Focused Ultrasound Array

    NASA Astrophysics Data System (ADS)

    Held, Robert; Nguyen, Thuc Nghi; Vaezy, Shahram

    2005-03-01

    The goal of this project is to develop a transvaginal image-guided High Intensity Focused Ultrasound (HIFU) device using piezocomposite HIFU array technology, and commercially-available ultrasound imaging. Potential applications include treatment of uterine fibroids and abnormal uterine bleeding. The HIFU transducer was an annular phased array, with a focal length range of 30-60 mm, an elliptically-shaped aperture of 35×60 mm, and an operating frequency of 3 MHz. A pillow-shaped bag with water circulation will be used for coupling the HIFU energy into the tissue. An intra-cavity imaging probe (C9-5, Philips) was integrated with the HIFU array such that the focal axis of the HIFU transducer was within the image plane. The entire device will be covered by a gel-filled condom when inserted in the vaginal cavity. To control it, software packages were developed in the LabView programming environment. An imaging algorithm processed the ultrasound image to remove noise patterns due to the HIFU signal. The device will be equipped with a three-dimensional tracking system, using a six-degrees-of-freedom articulating arm. Necrotic lesions were produced in a tissue-mimicking phantom and a turkey breast sample for all focal lengths. Various HIFU doses allow various necrotic lesion shapes, including thin ellipsoidal, spherical, wide cylindrical, and teardrop-shaped. Software control of the device allows multiple foci to be activated sequentially for desired lesion patterns. Ultrasound imaging synchronization can be achieved using hardware signals obtained from the imaging system, or software signals determined empirically for various imaging probes. The image-guided HIFU device will provide a valuable tool in visualization of uterine fibroid tumors for the purposes of planning and subsequent HIFU treatment of the tumor, all in a 3D environment. The control system allows for various lesions of different shapes to be optimally positioned in the tumor to cover the entire tumor

  9. Ultrasound contrast agents for bleeding detection and acoustic hemostasis

    NASA Astrophysics Data System (ADS)

    Zderic, Vesna; Luo, Wenbo; Brayman, Andrew; Crum, Lawrence; Vaezy, Shahram

    2005-04-01

    Objective: To investigate the application of ultrasound contrast agents (UCA) in improving both therapeutic and diagnostic aspects of ultrasound-guided High Intensity Focused Ultrasound (HIFU) therapy. Methods: Incisions (3 cm long, 0.5 cm deep) were made in rabbit livers (in anterior surface for HIFU treatment, or posterior surface for bleeding detection). UCA Optison (~0.1 ml/kg) was injected into mesenteric vein or ear vein. A HIFU applicator (5.5 MHz, 6400 W/cm2) was scanned manually over the incision until hemostasis was achieved. Occult bleeding was monitored with Doppler ultrasound. Results: The presence of Optison produced 37% reduction in hemostasis times normalized to initial bleeding rates. Gross and histological observations showed similar appearance of HIFU lesions produced in the presence of Optison and control HIFU lesions. The temperature reached 100°C in both HIFU only and HIFU+UCA treatments. Tension strength of hemostatic liver incisions was 0.9+/-0.5 N. Almost no bleeding could be detected before Optison injection. First appearance of contrast enhancement localized at the bleeding site was 15 s after Optison injection, and lasted for ~50 s. Conclusion: The presence of UCA during HIFU treatment of liver incisions resulted in shortening of HIFU application times and better visualization of bleeding sites.

  10. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    PubMed Central

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  11. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    PubMed

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or

  12. Long-axis view for ultrasound-guided central venous catheter placement via the internal jugular vein.

    PubMed

    Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus

    2016-04-01

    In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.

  13. Treatment of great auricular neuralgia with real-time ultrasound-guided great auricular nerve block

    PubMed Central

    Jeon, Younghoon; Kim, Saeyoung

    2017-01-01

    Abstract Rationale: The great auricular nerve can be damaged by the neck surgery, tumor, and long-time pressure on the neck. But, great auricular neuralgia is very rare condition. It was managed by several medication and landmark-based great auricular nerve block with poor prognosis. Patient concerns: A 25-year-old man presented with a pain in the left lateral neck and auricle. Diagnosis: He was diagnosed with great auricular neuralgia. Interventions: His pain was not reduced by medication. Therefore, the great auricular nerve block with local anesthetics and steroid was performed under ultrasound guidance. Outcomes: Ultrasound guided great auricular nerve block alleviated great auricular neuralgia. Lessons: This medication-resistant great auricular neuralgia was treated by the ultrasound guided great auricular nerve block with local anesthetic agent and steroid. Therefore, great auricular nerve block can be a good treatment option of medication resistant great auricular neuralgia. PMID:28328811

  14. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis.

    PubMed

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A; Quiles, Katherine G; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2018-01-01

    The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis.

  15. Comparison of corticosteroid, autologous blood or sclerosant injections for chronic tennis elbow.

    PubMed

    Branson, R; Naidu, K; du Toit, C; Rotstein, A H; Kiss, R; McMillan, D; Fooks, L; Coombes, B K; Vicenzino, B

    2017-06-01

    To compare three different ultrasound-guided injections for chronic tennis elbow. Assessor-blinded, randomized controlled comparative trial. 44 patients with clinically diagnosed tennis elbow, confirmed by Doppler ultrasound, received under ultrasound guidance, a single corticosteroid injection (n=14), or two injections (separated by 4 weeks) of either autologous blood (n=14) or polidocanol (n=16). Clinical and ultrasound examination was performed at baseline, 4, 12 and 26 weeks. Complete recovery or much improvement was greater for corticosteroid injection than autologous blood and polidocanol at 4 weeks (p<0.001, number needed to treat 1 (95% CI 1-2)). In contrast, at 26 weeks corticosteroid was significantly worse than polidocanol (p=0.004, number needed to harm 2 (1-6)). Recurrence after corticosteroid injection was significantly higher than autologous blood or polidocanol (p=0.007, number needed to harm 2 (1-4)). Corticosteroid injection produced greater reduction in tendon thickness and vascularity than autologous blood at 4 weeks only. Compared to autologous blood, polidocanol reduced tendon thickness at 4 and 12 weeks and reduced echogenicity and hyperaemia after 12 or 26 weeks respectively. Injections of corticosteroid cannot be recommended over polidocanol or autologous blood, because despite beneficial short-term effect there were inferior long-term effects. Whether polidocanol or autologous blood injections are effective is unknown, especially as their global effect profiles are not unlike previously reported for wait-and-see. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Comparison of the analgesic efficacy of ultrasound-guided rectus sheath block and local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children.

    PubMed

    Uchinami, Yuka; Sakuraya, Fumika; Tanaka, Nobuhiro; Hoshino, Koji; Mikami, Eri; Ishikawa, Taro; Fujii, Hitomi; Ishikawa, Takehiko; Morimoto, Yuji

    2017-05-01

    Ultrasound-guided rectus sheath block and local anesthetic infiltration are the standard options to improve postoperative pain for children undergoing surgery with a midline incision. However, there is no study comparing the effect of ultrasound-guided rectus sheath block with local anesthetic infiltration for children undergoing laparoscopic surgery. The aim of this trial was to compare the onset of ultrasound-guided rectus sheath block with that of local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children. We performed an observer-blinded, randomized, prospective trial. Enrolled patients were assigned to either an ultrasound-guided rectus sheath block group or a local anesthetic infiltration group. The ultrasound-guided rectus sheath block group (n = 17) received ultrasound-guided rectus sheath block with 0.2 ml·kg -1 of 0.375% ropivacaine per side in the posterior rectus sheath compartment. The local anesthetic infiltration group (n = 17) received local anesthetic infiltration with 0.2 ml·kg -1 of 0.75% ropivacaine. The Face, Legs, Activity, Cry, and Consolability (FLACC) pain scores were recorded at 0, 30, 60 min after arrival at the postanesthesia care unit. Of the 37 patients enrolled in this study, 34 completed the study protocol. A significant difference in the pain scale between the ultrasound-guided rectus sheath block group and local anesthetic infiltration group was found at 0 min (median: 0, interquartile range [IQR]: 0-1.5, vs median: 1, IQR 0-5, confidence interval of median [95% CI]: 0-3, P = 0.048), but no significant difference was found at 30 min (median: 1, IQR: 0-4 vs median: 6, IQR: 0-7, 95% CI: 0-5, P = 0.061), or 60 min (median: 0, IQR: 0-2 vs median: 1, IQR: 0-3, 95% CI: -1 to 1, P = 0.310). No significant difference was found in anesthesia time between the ultrasound-guided rectus sheath block and local anesthetic infiltration groups. No procedure-related complications were observed in either group

  17. An ultrasound needle insertion guide in a porcine phantom model.

    PubMed

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  18. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion.

    PubMed

    Venderink, Wulphert; Govers, Tim M; de Rooij, Maarten; Fütterer, Jurgen J; Sedelaar, J P Michiel

    2017-05-01

    Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. A decision tree and Markov model were developed to compare cost-effectiveness. Literature review and expert opinion were used as input. A strategy was deemed cost-effective if the costs of gaining one quality-adjusted life year (incremental cost-effectiveness ratio) did not exceed the willingness-to-pay threshold of €80,000 (≈$85,000 in January 2017). A base case analysis was performed to compare systematic transrectal ultrasound- and image fusion-guided biopsies. Because of a lack of appropriate literature regarding the accuracy of direct in-bore MRI-guided biopsy, a threshold analysis was performed. The incremental cost-effectiveness ratio for fusion-guided biopsy compared with systematic transrectal ultrasound-guided biopsy was €1386 ($1470) per quality-adjusted life year gained, which was below the willingness-to-pay threshold and thus assumed cost-effective. If MRI findings are normal in a patient with clinically significant prostate cancer, the sensitivity of direct in-bore MRI-guided biopsy has to be at least 88.8%. If that is the case, the incremental cost-effectiveness ratio is €80,000 per quality-adjusted life year gained and thus cost-effective. Fusion-guided biopsy seems to be cost-effective compared with systematic transrectal ultrasound-guided biopsy. Future research is needed to determine whether direct in-bore MRI-guided biopsy is the best pathway; in this study a threshold was calculated at which it would be cost-effective.

  19. Evaluation of a simplified augmented reality device for ultrasound-guided vascular access in a vascular phantom.

    PubMed

    Jeon, Yunseok; Choi, Seungpyo; Kim, Heechan

    2014-09-01

    To investigate whether a novel ultrasound device may be used with a simplified augmented reality technique, and to compare this device with conventional techniques during vascular access using a vascular phantom. Prospective, randomized study. Anesthesiology and Pain Medicine departments of a university-affiliated hospital. 20 physicians with no experience with ultrasound-guided techniques. All participants performed the vascular access technique on the vascular phantom model using both a conventional device and the new ultrasound device. Time and the number of redirections of the needle until aspiration of dye into a vessel of the vascular phantom were measured. The median/interquartile range of time was 39.5/41.7 seconds versus 18.6/10.0 seconds (P < 0.001) and number of redirections was 3/3.5 versus 1/0 (P < 0.001) for the conventional and novel ultrasound devices, respectively. During vascular access in a vascular phantom model, the novel device decreased the time and the number of redirections significantly. The device successfully improved the efficiency of the ultrasound-guided vascular access technique. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    NASA Astrophysics Data System (ADS)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  1. Cellular and Matrix Response of the Mandibular Condylar Cartilage to Botulinum Toxin

    PubMed Central

    Dutra, Eliane H.; O’ Brien, Mara H.; Lima, Alexandro; Kalajzic, Zana; Tadinada, Aditya; Nanda, Ravindra; Yadav, Sumit

    2016-01-01

    Objectives To evaluate the cellular and matrix effects of botulinum toxin type A (Botox) on mandibular condylar cartilage (MCC) and subchondral bone. Materials and Methods Botox (0.3 unit) was injected into the right masseter of 5-week-old transgenic mice (Col10a1-RFPcherry) at day 1. Left side masseter was used as intra-animal control. The following bone labels were intraperitoneally injected: calcein at day 7, alizarin red at day 14 and calcein at day 21. In addition, EdU was injected 48 and 24 hours before sacrifice. Mice were sacrificed 30 days after Botox injection. Experimental and control side mandibles were dissected and examined by x-ray imaging and micro-CT. Subsequently, MCC along with the subchondral bone was sectioned and stained with tartrate resistant acid phosphatase (TRAP), EdU, TUNEL, alkaline phosphatase, toluidine blue and safranin O. In addition, we performed immunohistochemistry for pSMAD and VEGF. Results Bone volume fraction, tissue density and trabecular thickness were significantly decreased on the right side of the subchondral bone and mineralized cartilage (Botox was injected) when compared to the left side. There was no significant difference in the mandibular length and condylar head length; however, the condylar width was significantly decreased after Botox injection. Our histology showed decreased numbers of Col10a1 expressing cells, decreased cell proliferation and increased cell apoptosis in the subchondral bone and mandibular condylar cartilage, decreased TRAP activity and mineralization of Botox injected side cartilage and subchondral bone. Furthermore, we observed reduced proteoglycan and glycosaminoglycan distribution and decreased expression of pSMAD 1/5/8 and VEGF in the MCC of the Botox injected side in comparison to control side. Conclusion Injection of Botox in masseter muscle leads to decreased mineralization and matrix deposition, reduced chondrocyte proliferation and differentiation and increased cell apoptosis in the

  2. Pre-procedure ultrasound-guided paramedian spinal anaesthesia at L5–S1: Is this better than landmark-guided midline approach? A randomised controlled trial

    PubMed Central

    Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2018-01-01

    Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151

  3. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2017-06-01

    standard transrectal ultrasound (TRUS) probe, a TUUS probe, and MRI. (a) (b) Figure 2: 3D printed prostate phantom mold (a), and pelvis phantom mold...with prostate agar phantom in place (b). The TUUS phantoms were prepared using a standard recipe [ii] for the prostate and the 3D printed mold...AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D -Transurethral Ultrasound and MRI Fusion PRINCIPAL

  4. Review of MRI positioning devices for guiding focused ultrasound systems.

    PubMed

    Yiallouras, C; Damianou, C

    2015-06-01

    This article contains a review of positioning devices that are currently used in the area of magnetic resonance imaging (MRI) guided focused ultrasound surgery (MRgFUS). The paper includes an extensive review of literature published since the first prototype system was invented in 1991. The technology has grown into a fast developing area with application to any organ accessible to ultrasound. The initial design operated using hydraulic principles, while the latest technology incorporates piezoelectric motors. Although, in the beginning there were fears regarding MRI safety, during recent years, the deployment of MR-safe positioning devices in FUS has become routine. Many of these positioning devices are now undergoing testing in clinical trials. Existing MRgFUS systems have been utilized mostly in oncology (fibroids, brain, liver, kidney, bone, pancreas, eye, thyroid, and prostate). It is anticipated that, in the near future, there will be a positioning device for every organ that is accessible by focused ultrasound. Copyright © 2014 John Wiley & Sons, Ltd.

  5. The cost-effectiveness of CT-guided sacroiliac joint injections: a measure of QALY gained.

    PubMed

    Bydon, Mohamad; Macki, Mohamed; De la Garza-Ramos, Rafael; Youssef, Mina; Gokaslan, Ziya L; Meleka, Sherif; Bydon, Ali

    2014-10-01

    The purpose of this study is to estimate the total cost and the quality of life years (QALY) gained for computer tomography (CT)-guided sacroiliac joint (SIJ) injections. The cost per QALY gained for the procedure is the primary end-point of this study. In our 1-year prospective institutional study, we gathered 30 patients undergoing CT-guided SIJ injections for degenerative changes at the SIJ space. Patient-reported outcomes included both the US population-based EQ-5D (EuroQol) index score and the EQ-visual analog scale (VAS). The EQ-5D is based on mobility, self-care, usual activities, pain/discomfort, and anxiety depression. Utility expenditures were based on hospital charges at our institution. All 30 patients had one pre-injection physician visit followed by 43 initial injections (13 bilateral). Each patient underwent one CT scan, and three patients required additional plain films. In the 1 year following the injections, 26 physician visits were documented. Five patients required repeat CT-guided injections. Total 1-year cost for all 30 patients was $34 874·00. Mean decrease in EQ-VAS was 0·60 (P  =  0·187). The mean 1-year gain of 0·58 EQ-5D QALY reached statistical significance (P < 0·001). The cost per QALY gained by CT-guided sacroiliac injections was $2004·29. In one of the first cost analyses of CT-guided sacroiliac injections, we found that the procedure improves pain and activities of daily living. The cost per QALY gained by CT-guided sacroiliac injections falls well below the threshold cost of 1 QALY, suggesting that the procedure is strongly cost-effective.

  6. Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.

    PubMed

    Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M

    2015-05-01

    Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.

  7. To switch from Botox to Dysport in children with CP, a real world, dose conversion, cost-effectiveness study.

    PubMed

    Tedroff, Kristina; Befrits, Gustaf; Tedroff, Carl Johan; Gantelius, Stefan

    2018-05-01

    Children with cerebral palsy (CP) are routinely treated with botulinum toxin A (BoNT-A). Two non dose-equivalent and differently priced products, Botox and Dysport are used. Depending on the conversion one of the products is considerably cheaper. However, the dose conversion factors studied to date have varied widely and relevant studies have not included children. Our objective here was to compare the efficacy and health economics of the switch from Botox to Dysport in children with CP when conversion was set to 1:2. Specifically were these treatments perceived as equivalent in terms of efficacy, duration and side-effects and were the drug cost lowered by using Dysport. This prospective, real-world, cost-effectiveness population-based observational study included all children with CP, (n = 159) mean age 9.4 years (SD, 4.3), in the larger Stockholm area who received BoNT-A between September 1, 2014, and December 31, 2015. Parents reported the efficacy, duration and side-effects of previous treatment while physicians reported doses and goals set by children and parents for the present treatment. Drug acquisition costs were provided by county administrators. In connection with 341 visits caregivers reported comparable effects of similar duration with these products, with few, similar and transient side-effects. The drug-cost per treatment was 4029 SEK for Botox and 2380 SEK in the case of Dysport. When Botox was replaced by a two-fold higher Unit dose of Dysport (conversion 1:2) parents perceived the treatment of their children with CP to be equally effective while the cost was 41% lower according to procured prices. Copyright © 2018 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

  8. Ultrasound-Guided Rectus Sheath Block in Gynaecological Surgery with Pfannenstiel Incision

    PubMed Central

    Cüneyitoğlu, Şule; Türktan, Mediha; Biricik, Ebru; Özcengiz, Dilek

    2015-01-01

    Objective This study aimed to evaluate the effects of ultrasound-guided rectus sheath block in gynaecological surgery with Pfannenstiel incision. Methods After the approval of the ethics committee and the patients’ consent, 75 ASA I–II patients who were aged between 20 and 70 years and scheduled for a gynaecological surgery with Pfannenstiel incision were included in this study. After induction of general anaesthesia, patients were randomly divided into three groups. In Group UR patients (n=25), ultrasound-guided rectus sheath block with 0.25% levobupivacaine (0.2 mL kg−1) was performed. In Group SR patients (n=25), surgical rectus sheath block with 0.25% levobupivacaine (0.2 mL kg−1) was applied. In Group T (n=25) patients, tramadol (2 mg kg−1) was intravenously administered 30 min before the end of surgery. Patient-controlled analgesia device was established for postoperative pain relief in all groups. Haemodynamic data and inspired sevoflurane concentration were recorded during the operation. Pain scores, total tramadol consumption, supplemental analgesic requirement and side effects were postoperatively evaluated. Results Demographic characteristics, duration of surgery and haemodynamic parameters were similar between the groups. Inspired sevoflurane concentration (%) and VAS scores were significantly lower in Group UR than those in Groups SR and T. Total tramadol consumption was significantly lower in Groups UR and SR than that in Group T. There was no significant difference in the incidence of side effects. Conclusion This study demonstrates that ultrasound-guided rectus sheath block helps to provide the effective analgesia without any side effects compared with surgical rectus sheath block and intravenous tramadol for gynaecological surgery with Pfannenstiel incision. PMID:27366521

  9. Ultrasound-Guided Rectus Sheath Block in Gynaecological Surgery with Pfannenstiel Incision.

    PubMed

    Cüneyitoğlu, Şule; Türktan, Mediha; Biricik, Ebru; Özcengiz, Dilek

    2015-10-01

    This study aimed to evaluate the effects of ultrasound-guided rectus sheath block in gynaecological surgery with Pfannenstiel incision. After the approval of the ethics committee and the patients' consent, 75 ASA I-II patients who were aged between 20 and 70 years and scheduled for a gynaecological surgery with Pfannenstiel incision were included in this study. After induction of general anaesthesia, patients were randomly divided into three groups. In Group UR patients (n=25), ultrasound-guided rectus sheath block with 0.25% levobupivacaine (0.2 mL kg(-1)) was performed. In Group SR patients (n=25), surgical rectus sheath block with 0.25% levobupivacaine (0.2 mL kg(-1)) was applied. In Group T (n=25) patients, tramadol (2 mg kg(-1)) was intravenously administered 30 min before the end of surgery. Patient-controlled analgesia device was established for postoperative pain relief in all groups. Haemodynamic data and inspired sevoflurane concentration were recorded during the operation. Pain scores, total tramadol consumption, supplemental analgesic requirement and side effects were postoperatively evaluated. Demographic characteristics, duration of surgery and haemodynamic parameters were similar between the groups. Inspired sevoflurane concentration (%) and VAS scores were significantly lower in Group UR than those in Groups SR and T. Total tramadol consumption was significantly lower in Groups UR and SR than that in Group T. There was no significant difference in the incidence of side effects. This study demonstrates that ultrasound-guided rectus sheath block helps to provide the effective analgesia without any side effects compared with surgical rectus sheath block and intravenous tramadol for gynaecological surgery with Pfannenstiel incision.

  10. Laparoscopic Heller Myotomy Provides Durable Relief From Achalasia and Salvages Failures After Botox or Dilation

    PubMed Central

    Rosemurgy, Alexander; Villadolid, Desiree; Thometz, Donald; Kalipersad, Candice; Rakita, Steven; Albrink, Michael; Johnson, Milton; Boyce, Worth

    2005-01-01

    Objective: To report outcome after laparoscopic Heller myotomy in a large number of patients. Summary Background Data: Laparoscopic Heller myotomy has been undertaken for over a decade, but most studies involve small numbers of patients with limited follow-up. Methods: Since 1992, 262 patients have undergone laparoscopic Heller myotomy and been prospectively followed. Concomitant fundoplication was undertaken for a patulous hiatus or large hiatal hernia or to buttress the repair of an esophagotomy until recently when it became routinely applied. With mean follow-up at 32months, symptoms were scored by patients on a Likert scale (frequency: 0 = Never to 10 = Every time I eat/always; severity: 0 = Not bothersome to 10 = Very bothersome). Results: Before myotomy, 79% received Botox or bag dilation: 52% had Botox, 59% underwent dilation, and 36% had both. Inadvertent esophagotomy occurred in 5%. Concomitant diverticulectomy was undertaken in 4%, and fundoplication was undertaken in 30%. Complications were infrequent. Median length of stay was 1 day. After myotomy, the frequency and severity of symptoms of achalasia and reflux significantly decreased. Eighty-eight percent of patients felt their symptoms were greatly improved or resolved, and 90% felt their outcome was satisfying or better. Ninety-three percent felt they would undergo myotomy again, if necessary. Conclusions: Laparoscopic Heller myotomy can safely and durably relieve symptoms of dysphagia while also reducing symptoms of reflux. Length of stay is short and patient satisfaction is very high with extended follow-up. Laparoscopic Heller myotomy is strongly encouraged for patients with symptomatic achalasia and is efficacious even after failures of dilation and/or Botox therapy. PMID:15849508

  11. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    PubMed

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  12. MR-guided focused ultrasound: a potentially disruptive technology.

    PubMed

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  13. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    PubMed Central

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  14. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a

  15. Impact of Focused Ultrasound-enhanced Drug Delivery on Survival in Rats with Glioma

    NASA Astrophysics Data System (ADS)

    Treat, Lisa Hsu; Zhang, Yongzhi; McDannold, Nathan; Hynynen, Kullervo

    2009-04-01

    Malignancies of the brain remain difficult to treat with chemotherapy because the selective permeability of the blood-brain barrier (BBB) blocks many potent agents from reaching their target. Previous studies have illustrated the feasibility of drug and antibody delivery across the BBB using MRI-guided focused ultrasound. In this study, we investigated the impact of focused ultrasound-enhanced delivery of doxorubicin on survival in rats with aggressive glioma. Sprague-Dawley rats were implanted with 9 L gliosarcoma cells in the brain. Eight days after implantation, each rat received one of the following: (1) no treatment (control), (2) a single treatment with microbubble-enhanced MRI-guided focused ultrasound (FUS only), (3) a single treatment with i.v. liposomal doxorubicin (DOX only), or (4) a single treatment with microbubble-enhanced MRI-guided focused ultrasound and concurrent i.v. injections of liposomal doxorubicin (FUS+DOX). The survival time from implantation to death or euthanasia was recorded. We observed a modest but significant increase in median survival time in rats treated with combined MRI-guided focused ultrasound chemotherapy, compared to chemotherapy alone (p<0.001). There was no significant improvement in survival between those who received stand-alone chemotherapy and those who did not receive any treatment (p>0.10). Our study demonstrates for the first time a therapeutic benefit achieved with ultrasound-enhanced drug delivery across the blood-brain barrier. This confirmation of efficacy in an in vivo tumor model indicates that targeted drug delivery using MRI-guided focused ultrasound has the potential to have a major impact on the treatment of patients with brain tumors and other neurological disorders.

  16. Botulinum toxin effects on gasatrocnemius strength and plantar pressure in diabetics with peripheral neuropathy and forefoot ulceration.

    PubMed

    Hastings, Mary K; Mueller, Michael J; Sinacore, David R; Strube, Michael J; Crowner, Beth E; Johnson, Jeffrey E; Racette, Brad R

    2012-05-01

    High forefoot plantar pressure is associated with plantar ulcers in people with diabetes and peripheral neuropathy. The purpose of this pilot study was to determine the safety and efficacy of botulinum toxin A injected into the gastrocnemius-soleus muscles to reduce muscle strength and plantar pressure. This double blind, randomized clinical trial studied 17 people with diabetes mellitus, peripheral neuropathy and a forefoot plantar ulcer. Subjects were randomized into one of three groups receiving gastrocnemius-soleus muscle injections on the involved side with; 1) Saline (n = 5, weight =99± 21 kg), 2) 200-units of Botox® (n = 7, weight = 101± 5 kg), or 3) 300-units of Botox® (n = 5, weight = 129± 22 kg). Botox® dose was converted to units/kg, the majority received between 1.9 and 2.4 units/kg (n = 11) and one 3.2 units/kg. Plantarflexor peak torque and forefoot peak plantar pressure were quantified prior and 2 weeks post-injection. There were no complications from the injections. Plantarflexor peak torque on the involved side increased in the placebo and 300 groups (3± 4 Nm and 6± 10 Nm, respectively) and decreased -8± 11 Nm in the 200 group. There was no relationship between units/kg of Botox® for each subject and change in plantarflexor peak torque. Forefoot peak plantar pressure did not change in the placebo and 300 groups (0± 11 and 0± 5 N/cm(2), respectively) and decreased -4± 16 N/cm2 (4%) for the 200 group. There were no adverse events associated with the Botox® injections. This study was unable to determine the dose to consistently reduce plantarflexor strength and forefoot plantar pressure. Additional research is needed to investigate diabetes mellitus specific physiological changes and their impact of BoNT-A effectiveness in order to guide appropriate dosing.

  17. Greater Trochanteric Pain Syndrome: Percutaneous Tendon Fenestration Versus Platelet-Rich Plasma Injection for Treatment of Gluteal Tendinosis.

    PubMed

    Jacobson, Jon A; Yablon, Corrie M; Henning, P Troy; Kazmers, Irene S; Urquhart, Andrew; Hallstrom, Brian; Bedi, Asheesh; Parameswaran, Aishwarya

    2016-11-01

    The purpose of this study was to compare ultrasound-guided percutaneous tendon fenestration to platelet-rich plasma (PRP) injection for treatment of greater trochanteric pain syndrome. After Institutional Review Board approval was obtained, patients with symptoms of greater trochanteric pain syndrome and ultrasound findings of gluteal tendinosis or a partial tear (<50% depth) were blinded and treated with ultrasound-guided fenestration or autologous PRP injection of the abnormal tendon. Pain scores were recorded at baseline, week 1, and week 2 after treatment. Retrospective clinic record review assessed patient symptoms. The study group consisted of 30 patients (24 female), of whom 50% were treated with fenestration and 50% were treated with PRP. The gluteus medius was treated in 73% and 67% in the fenestration and PRP groups, respectively. Tendinosis was present in all patients. In the fenestration group, mean pain scores were 32.4 at baseline, 16.8 at time point 1, and 15.2 at time point 2. In the PRP group, mean pain scores were 31.4 at baseline, 25.5 at time point 1, and 19.4 at time point 2. Retrospective follow-up showed significant pain score improvement from baseline to time points 1 and 2 (P< .0001) but no difference between treatment groups (P= .1623). There was 71% and 79% improvement at 92 days (mean) in the fenestration and PRP groups, respectively, with no significant difference between the treatments (P >.99). Our study shows that both ultrasound-guided tendon fenestration and PRP injection are effective for treatment of gluteal tendinosis, showing symptom improvement in both treatment groups. © 2016 by the American Institute of Ultrasound in Medicine.

  18. Laparoscopic-guided abdominal wall nerve blocks in the pediatric population: a novel technique with comparison to ultrasound-guided blocks and local wound infiltration alone.

    PubMed

    Landmann, Alessandra; Visoiu, Mihaela; Malek, Marcus M

    2018-03-01

    Abdominal wall nerve blocks have been gaining popularity for the treatment of perioperative pain in children. Our aim was to compare a technique of surgeon-performed, laparoscopic abdominal wall nerve blocks to anesthesia-placed, ultrasound-guided abdominal wall nerve blocks and the current standard of local wound infiltration. After institutional review board approval was obtained, a retrospective chart review was performed of pediatric patients treated at a single institution during a 2-year period. Statistics were calculated using analysis of variance with post-hoc Bonferonni t tests for pair-wise comparisons. Included in this study were 380 patients who received ultrasound-guided abdominal wall nerve blocks (n = 125), laparoscopic-guided abdominal wall nerve blocks (n = 88), and local wound infiltration (n = 117). Groups were well matched for age, sex, and weight. There was no significant difference in pain scores within the first 8 hours or narcotic usage between groups. Local wound infiltration demonstrated the shortest overall time required to perform (P < .0001). Patients who received a surgeon-performed abdominal wall nerve block demonstrated a shorter duration of hospital stay when compared to the other groups (P = .02). Our study has demonstrated that laparoscopic-guided abdominal wall nerve blocks show similar efficacy to ultrasound-guided nerve blocks performed by pain management physicians without increasing time in the operating room. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deli, Martin, E-mail: martin.deli@web.de; Fritz, Jan, E-mail: jfritz9@jhmi.edu; Mateiescu, Serban, E-mail: mateiescu@microtherapy.de

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 withmore » gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.« less

  20. Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

    PubMed Central

    Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung

    2017-01-01

    Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656

  1. High-intensity focused ultrasound (HIFU) array system for image-guided ablative therapy (IGAT)

    NASA Astrophysics Data System (ADS)

    Kaczkowski, Peter J.; Keilman, George W.; Cunitz, Bryan W.; Martin, Roy W.; Vaezy, Shahram; Crum, Lawrence A.

    2003-06-01

    Recent interest in using High Intensity Focused Ultrasound (HIFU) for surgical applications such as hemostasis and tissue necrosis has stimulated the development of image-guided systems for non-invasive HIFU therapy. Seeking an all-ultrasound therapeutic modality, we have developed a clinical HIFU system comprising an integrated applicator that permits precisely registered HIFU therapy delivery and high quality ultrasound imaging using two separate arrays, a multi-channel signal generator and RF amplifier system, and a software program that provides the clinician with a graphical overlay of the ultrasound image and therapeutic protocol controls. Electronic phasing of a 32 element 2 MHz HIFU annular array allows adjusting the focus within the range of about 4 to 12 cm from the face. A central opening in the HIFU transducer permits mounting a commercial medical imaging scanhead (ATL P7-4) that is held in place within a special housing. This mechanical fixture ensures precise coaxial registration between the HIFU transducer and the image plane of the imaging probe. Recent enhancements include development of an acoustic lens using numerical simulations for use with a 5-element array. Our image-guided therapy system is very flexible and enables exploration of a variety of new HIFU therapy delivery and monitoring approaches in the search for safe, effective, and efficient treatment protocols.

  2. Healing of rotator cuff tendons using botulinum toxin A and immobilization in a rat model.

    PubMed

    Gilotra, Mohit N; Shorofsky, Michael J; Stein, Jason A; Murthi, Anand M

    2016-03-15

    We evaluated effects of botulinum toxin A (Botox) and cast immobilization on tendon healing in a rat model. Injection of Botox into rat supraspinatus was hypothesized to reduce muscle active force and improved healing. Eighty-four supraspinatus tendons were surgically transected and repaired in 42 Sprague-Dawley rats (transosseous technique). After repair, supraspinatus muscle was injected with saline or Botox (3 or 6 U/kg). Half the shoulders were cast-immobilized for the entire postoperative period; half were allowed free cage activity. Histology was examined at 2, 4, 8, and 12 weeks. A healing zone cross-sectional area was measured, and biomechanical testing of repair strength and tendon viscoelastic properties was conducted at 4 and 12 weeks. Botox alone and cast immobilization alone exhibited increased ultimate load compared with controls (saline injection, no immobilization) at 4 weeks. No difference in ultimate load occurred between Botox-only and cast-only groups. At 12 weeks, the Botox (6 U/kg) plus cast immobilization group was significantly weakest (p < 0.05). A trend was shown toward decreased healing zone cross-sectional areas in casted groups. Supraspinatus Botox injection after rotator cuff repair might help protect the repair. However, cast immobilization plus Botox administration is harmful to rotator cuff healing in a rat tendon model.

  3. Fluoroscopically Guided Peritendinous Corticosteroid Injection for Proximal Hamstring Tendinopathy

    PubMed Central

    Nicholson, Luke T.; DiSegna, Steven; Newman, Joel S.; Miller, Suzanne L.

    2014-01-01

    Background: Proximal hamstring tendinopathy is an uncommon but debilitating cause of posterior thigh pain in athletes subjected to repetitive eccentric hamstring contraction, such as runners. Minimal data exist evaluating treatment options for proximal hamstring tendinopathy. Purpose: This retrospective study evaluates the effectiveness of fluoroscopically guided corticosteroid injections in treating proximal hamstring tendinopathy. Study Design: Case series; Level of evidence, 4. Methods: Eighteen athletes with 22 cases of magnetic resonance imaging–confirmed proximal hamstring tendinopathy were treated with corticosteroid injection and later contacted to evaluate the efficacy of the injection with the use of a questionnaire. Results: The visual analog score decreased from 7.22 preinjection to 3.94 postinjection (P < .001), level of athletic participation increased from 28.76% to 68.82% (P < .001) at a mean follow-up of 21 months, and 38.8% of patients experienced complete resolution at a mean follow-up of 24.8 months. The mean lower extremity function score at the time of follow-up was 60. Conclusion: A trial of fluoroscopically guided corticosteroid injection is warranted in patients presenting with symptoms of proximal hamstring tendinopathy refractory to conservative therapy. PMID:26535310

  4. Fluoroscopically Guided Diagnostic and Therapeutic Intra-Articular Sacroiliac Joint Injections: A Systematic Review.

    PubMed

    Kennedy, David J; Engel, Andrew; Kreiner, D Scott; Nampiaparampil, Devi; Duszynski, Belinda; MacVicar, John

    2015-08-01

    To assess the validity of fluoroscopically guided diagnostic intra-articular injections of local anesthetic and effectiveness of intra-articular steroid injections in treating sacroiliac joint (SIJ) pain. Systematic review. Ten reviewers independently assessed 45 publications on diagnostic validity or effectiveness of fluoroscopically guided intra-articular SIJ injections. For diagnostic injections, the primary outcome was validity; for therapeutic injections, analgesia. Secondary outcomes were also described. Of 45 articles reviewed, 39 yielded diagnostic data on physical exam findings, provocation tests, and SIJ injections for diagnosing SIJ pain, and 15 addressed therapeutic effectiveness. When confirmed by comparative local anesthetic blocks with a high degree of pain relief, no single physical exam maneuver predicts response to diagnostic injections. When at least three physical exam findings are present, sensitivity, and specificity increases significantly. The prevalence of SIJ pain is likely 20-30% among patients that have suspected SIJ pain based on history and physical examination. This estimate may be higher in certain subgroups such as the elderly and fusion patients. Two randomized controlled trials and multiple observational studies supported the effectiveness of therapeutic sacroiliac joint injections. Based on this literature, it is unclear whether image-guided intra-articular diagnostic injections of local anesthetic predict positive responses to therapeutic agents. The overall quality of evidence is moderate for the effectiveness of therapeutic SIJ injections. Wiley Periodicals, Inc.

  5. Pilot cohort study of endoscopic botulinum neurotoxin injection in Parkinson's disease.

    PubMed

    Triadafilopoulos, George; Gandhy, Rita; Barlow, Carrolee

    2017-11-01

    Gastrointestinal symptoms, such as dysphagia, postprandial bloating, and defecatory straining are common in Parkinson's Disease (PD) and they impact quality of life. Endoscopic botulinum neurotoxin (BoNT) injection has been used in the treatment of dysphagia, gastroparesis and chronic anismus. To examine the feasibility, safety and efficacy of endoscopically delivered BoNT injection to distal esophagus, pylorus or anal canal aiming at relieving regional gastrointestinal symptoms in patients with PD. This is a retrospective open cohort pilot study to assess the clinical response to endoscopic BoNT injection on selected PD patients with symptoms and identifiable abnormalities on high-resolution manometry and wireless motility capsule, to generate early uncontrolled data on feasibility, tolerability, safety and efficacy. Baseline symptoms and response to therapy were assessed by questionnaires. Fourteen PD patients (10 M:4 F), mean age 73 (range: 62-93) were treated. Three patients had esophageal Botox for ineffective esophageal motility (IEM) (n = 1), esophago-gastric junction outlet obstruction (EGJOO) & IEM (n = 1), and diffuse esophageal spasm (DES) (n = 1). Nine patients were treated with pyloric BoNT injection for gastroparesis with mean gastric transit time of 21.2 h; range 5.2-44.2 h. Two patients received anal Botox for defecatory dyssynergia ((Type I) (n = 1) and overlap (slow-transit and dyssynergic) constipation (n = 1). Endoscopic BoNT injection (100-200 units) was well tolerated and there were no significant adverse events. Endoscopic BoNT injection to esophagus, pylorus or anal canal is safe, well-tolerated and leads to symptomatic improvement that lasts up to several months. The procedure can be repeated as needed and combined with other therapies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Accuracy of electromyography needle placement in cadavers: non-guided vs. ultrasound guided.

    PubMed

    Boon, Andrea J; Oney-Marlow, Theresa M; Murthy, Naveen S; Harper, Charles M; McNamara, Terrence R; Smith, Jay

    2011-07-01

    Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory. Copyright © 2011 Wiley Periodicals, Inc.

  7. A pitfall during endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes.

    PubMed

    Krenke, Rafal; Korczynski, Piotr; Gorska, Katarzyna; Chazan, Ryszarda

    2014-03-01

    The high diagnostic yield and favorable safety profile of endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes have been recently demonstrated. We report an unusual technical problem during endobronchial ultrasound-guided transbronchial forceps biopsy that could be a prerequisite for severe complications. A rupture of the steering band precluded closure of the forceps jaws opened in the subcarinal lymph node. A solution to the problem is presented, together with other procedure-related complications reported in the literature. The report emphasizes that a dysfunction of the forceps steering band can result in severe complications when it occurs during transbronchial sampling of mediastinal lesions. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis.

    PubMed

    Keil-Ríos, Daniel; Terrazas-Solís, Hiram; González-Garay, Alejandro; Sánchez-Ávila, Juan Francisco; García-Juárez, Ignacio

    2016-04-01

    The pocket ultrasound device (PUD) is a new tool that may be of use in the early detection of ascites. Abdominal ultrasound-guided paracentesis has been reported to decrease the rate of complications due to the procedure, but must be performed in a healthcare setting; this new tool may be a useful on an ambulatory basis. The aim of this study was to determine the diagnostic usefulness of the PUD in the diagnosis of ascites and the safety of guided paracentesis. We conducted a retrospective study that included adult patients suspected of having ascites and in whom an evaluation was performed with the PUD to identify it. Concordance with abdominal ultrasound (AUS) was determined with the Kappa coefficient. Sensitivity (Se), specificity (Sp) and likelihood ratios (LR) were determined and compared with physical examination, AUS, computed tomography and procurement of fluid by paracentesis. Complications resulting from the guided paracentesis were analyzed. 89 participants were included and 40 underwent a paracentesis. The PUD for ascites detection had 95.8 % Se, 81.8 % Sp, 5.27 +LR and 0.05 -LR. It had a concordance with AUS of 0.781 (p < 0.001). Technical problems during the guided paracentesis were present in only two participants (5 %) and three patients (7.5 %) developed minor complications that required no further intervention. There were no severe complications or deaths. This study suggests that the PUD is a reliable tool for ascites detection as a complement to physical examination and appears to be a safe method to perform guided paracentesis.

  9. A serious game for learning ultrasound-guided needle placement skills.

    PubMed

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  10. Non-Invasive Targeted Peripheral Nerve Ablation Using 3D MR Neurography and MRI-Guided High-Intensity Focused Ultrasound (MR-HIFU): Pilot Study in a Swine Model.

    PubMed

    Huisman, Merel; Staruch, Robert M; Ladouceur-Wodzak, Michelle; van den Bosch, Maurice A; Burns, Dennis K; Chhabra, Avneesh; Chopra, Rajiv

    2015-01-01

    Ultrasound (US)-guided high intensity focused ultrasound (HIFU) has been proposed for noninvasive treatment of neuropathic pain and has been investigated in in-vivo studies. However, ultrasound has important limitations regarding treatment guidance and temperature monitoring. Magnetic resonance (MR)-imaging guidance may overcome these limitations and MR-guided HIFU (MR-HIFU) has been used successfully for other clinical indications. The primary purpose of this study was to evaluate the feasibility of utilizing 3D MR neurography to identify and guide ablation of peripheral nerves using a clinical MR-HIFU system. Volumetric MR-HIFU was used to induce lesions in the peripheral nerves of the lower limbs in three pigs. Diffusion-prep MR neurography and T1-weighted images were utilized to identify the target, plan treatment and immediate post-treatment evaluation. For each treatment, one 8 or 12 mm diameter treatment cell was used (sonication duration 20 s and 36 s, power 160-300 W). Peripheral nerves were extracted < 3 hours after treatment. Ablation dimensions were calculated from thermal maps, post-contrast MRI and macroscopy. Histological analysis included standard H&E staining, Masson's trichrome and toluidine blue staining. All targeted peripheral nerves were identifiable on MR neurography and T1-weighted images and could be accurately ablated with a single exposure of focused ultrasound, with peak temperatures of 60.3 to 85.7°C. The lesion dimensions as measured on MR neurography were similar to the lesion dimensions as measured on CE-T1, thermal dose maps, and macroscopy. Histology indicated major hyperacute peripheral nerve damage, mostly confined to the location targeted for ablation. Our preliminary results indicate that targeted peripheral nerve ablation is feasible with MR-HIFU. Diffusion-prep 3D MR neurography has potential for guiding therapy procedures where either nerve targeting or avoidance is desired, and may also have potential for post

  11. Non-Invasive Targeted Peripheral Nerve Ablation Using 3D MR Neurography and MRI-Guided High-Intensity Focused Ultrasound (MR-HIFU): Pilot Study in a Swine Model

    PubMed Central

    Huisman, Merel; Staruch, Robert M.; Ladouceur-Wodzak, Michelle; van den Bosch, Maurice A.; Burns, Dennis K.; Chhabra, Avneesh; Chopra, Rajiv

    2015-01-01

    Purpose Ultrasound (US)-guided high intensity focused ultrasound (HIFU) has been proposed for noninvasive treatment of neuropathic pain and has been investigated in in-vivo studies. However, ultrasound has important limitations regarding treatment guidance and temperature monitoring. Magnetic resonance (MR)-imaging guidance may overcome these limitations and MR-guided HIFU (MR-HIFU) has been used successfully for other clinical indications. The primary purpose of this study was to evaluate the feasibility of utilizing 3D MR neurography to identify and guide ablation of peripheral nerves using a clinical MR-HIFU system. Methods Volumetric MR-HIFU was used to induce lesions in the peripheral nerves of the lower limbs in three pigs. Diffusion-prep MR neurography and T1-weighted images were utilized to identify the target, plan treatment and immediate post-treatment evaluation. For each treatment, one 8 or 12 mm diameter treatment cell was used (sonication duration 20 s and 36 s, power 160–300 W). Peripheral nerves were extracted < 3 hours after treatment. Ablation dimensions were calculated from thermal maps, post-contrast MRI and macroscopy. Histological analysis included standard H&E staining, Masson’s trichrome and toluidine blue staining. Results All targeted peripheral nerves were identifiable on MR neurography and T1-weighted images and could be accurately ablated with a single exposure of focused ultrasound, with peak temperatures of 60.3 to 85.7°C. The lesion dimensions as measured on MR neurography were similar to the lesion dimensions as measured on CE-T1, thermal dose maps, and macroscopy. Histology indicated major hyperacute peripheral nerve damage, mostly confined to the location targeted for ablation. Conclusion Our preliminary results indicate that targeted peripheral nerve ablation is feasible with MR-HIFU. Diffusion-prep 3D MR neurography has potential for guiding therapy procedures where either nerve targeting or avoidance is desired, and may

  12. Local Methotrexate Injection as the First-line Treatment for Cesarean Scar Pregnancy: Review of the Literature.

    PubMed

    Cheung, Vincent Y T

    2015-01-01

    The objective of this study was to determine the outcome of using ultrasound-guided local methotrexate injection as the first-line treatment of cesarean scar pregnancy (CSP). A literature review was performed on all eligible reports using this modality as the first-line treatment of CSP. Relevant publications were obtained from the PubMed electronic database from inception to December 2014. Ninety-six cases from 95 women reported in 17 articles were reviewed. The success rate was 73.9% after a single local methotrexate injection. An accumulated success rate of 88.5% could be achieved after additional local or intramuscular methotrexate administration. Eleven cases (11.5%) failed methotrexate treatment and required surgical interventions. Except for women with serum human chorionic gonadotropin levels higher than 100 000 IU/L, ultrasound-guided local methotrexate injection could be considered as a first-line treatment modality for CSP. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  13. Botulinum toxin is detrimental to repair of a chronic rotator cuff tear in a rabbit model.

    PubMed

    Gilotra, Mohit; Nguyen, Thao; Christian, Matthew; Davis, Derik; Henn, R Frank; Hasan, Syed Ashfaq

    2015-08-01

    Re-tear continues to be a problem after rotator cuff repair. Intramuscular botulinum toxin (Botox) injection can help optimize tension at the repair site to promote healing but could have an adverse effect on the degenerated muscle in a chronic tear. We hypothesized that Botox injection would improve repair characteristics without adverse effect on the muscle in a chronic rotator cuff tear model. The supraspinatus tendon of both shoulders in 14 rabbits underwent delayed repair 12 weeks after transection. One shoulder was treated with intramuscular Botox injection and the other with a saline control injection. Six weeks after repair, outcomes were based on biomechanics, histology, and magnetic resonance imaging. Botox-treated repairs were significantly weaker (2.64 N) than control repairs (5.51 N, p = 0.03). Eighty percent of Botox-treated repairs and 40% of control repairs healed with some partial defect. Fatty infiltration of the supraspinatus was present in all shoulders (Goutallier Grade 3 or 4) but was increased in the setting of Botox. This study provides additional support for the rabbit supraspinatus model of chronic cuff tear, showing consistent fatty infiltration. Contrary to our hypothesis, Botox had a negative effect on repair strength and might increase fatty infiltration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Changes in contractile properties of muscles receiving repeat injections of botulinum toxin (Botox).

    PubMed

    Fortuna, Rafael; Vaz, Marco Aurélio; Youssef, Aliaa Rehan; Longino, David; Herzog, Walter

    2011-01-04

    Botulinum toxin type A (BTX-A) is a frequently used therapeutic tool to denervate muscles in the treatment of neuromuscular disorders. Although considered safe by the US Food and Drug Administration, BTX-A can produce adverse effects in target and non-target muscles. With an increased use of BTX-A for neuromuscular disorders, the effects of repeat injections of BTX-A on strength, muscle mass and structure need to be known. Therefore, the purpose of this study was to investigate the changes in strength, muscle mass and contractile material in New Zealand White (NZW) rabbits. Twenty NZW rabbits were divided into 4 groups: control and 1, 3 and 6 months of unilateral, repeat injections of BTX-A into the quadriceps femoris. Outcome measures included knee extensor torque, muscle mass and the percentage of contractile material in the quadriceps muscles of the target and non-injected contralateral hindlimbs. Strength in the injected muscles was reduced by 88%, 89% and 95% in the 1, 3 and 6 months BTX-A injected hindlimbs compared to controls. Muscle mass was reduced by 50%, 42% and 31% for the vastus lateralis (VL), rectus femoris (RF) and vastus medialis (VM), respectively, at 1 month, by 68%, 51% and 50% at 3 months and by 76%, 44% and 13% at 6 months. The percentage of contractile material was reduced for the 3 and 6 months animals to 80-64%, respectively, and was replaced primarily by fat. Similar, but less pronounced results were also observed for the quadriceps muscles of the contralateral hindlimbs, suggesting that repeat BTX-A injections cause muscle atrophy and loss of contractile tissue in target muscles and also in non-target muscles that are far removed from the injection site. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Shall We Inject Superficial or Deep to the Plantar Fascia? An Ultrasound Study of the Treatment of Chronic Plantar Fasciitis.

    PubMed

    Gurcay, Eda; Kara, Murat; Karaahmet, Ozgur Zeliha; Ata, Ayşe Merve; Onat, Şule Şahin; Özçakar, Levent

    We compared the effectiveness of ultrasound (US)-guided corticosteroid, injected superficial or deep to the fascia, in patients with plantar fasciitis. Thirty patients (24 females [75%] and 6 males [25%]) with unilateral chronic plantar fasciitis were divided into 2 groups according to the corticosteroid injection site: superficial (n = 15) or deep (n = 15) to the plantar fascia. Patient heel pain was measured using a Likert pain scale and the Foot Ankle Outcome Scale (FAOS) for foot disability, evaluated at baseline and repeated in the first and sixth weeks. The plantar fascia and heel pad thicknesses were assessed on US scans at baseline and the sixth week. The groups were similar in age, gender, and body mass index (p > .05 for all). Compared with the baseline values, the Likert pain scale (p < .001 for all) and FAOS subscale (p < .01 for all) scores had improved at the first and sixth week follow-up visits in both groups. Although the plantar fascia thickness had decreased significantly in both groups at the sixth week (p < .001 for both), the heel pad thickness remained unchanged (p > .05 for both). The difference in the FAOS subscales (pain, p = .002; activities of daily living, p = .003; sports/recreational activities, p = .008; quality of life, p = .009) and plantar fascia thickness (p = .049) showed better improvement in the deep than in the superficial injection group. US-guided corticosteroid injections are safe and effective in the short-term therapeutic outcome of chronic plantar fasciitis. Additionally, injection of corticosteroid deep to the fascia might result in greater reduction in plantar fascia thickness, pain, and disability and improved foot-related quality of life. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Value of artisanal simulators to train veterinary students in performing invasive ultrasound-guided procedures.

    PubMed

    Hage, Maria Cristina F N S; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-03-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are recommended for this practice. The present study aimed to create a model that can be made "at home" at low cost for ultrasound-guided pericardiocentesis training and to gather feedback about this model through questionnaires given to the participants. Eighteen professionals and thirty-six students were introduced to the simulator in pairs. After the simulation training session, participants filled out the questionnaire. Participants considered the model strong in the following areas: visualization of the pericardium, the heart, fluid in the pericardium, and fluid decrease during fictitious pericardiocentesis and its realism. They considered the model weak or moderate in the following areas: visualization of the surrounding tissues, difficulty of pericardial puncture, and visualization of the catheter. The professionals classified the realism of the experimental heart as moderate, whereas the undergraduate students classified it as strong. All participants believed that the experimental model could be useful in preparing for a future real situation. This model fulfills the need for a practical, realistic, and cost-effective model for ultrasound-guided pericardiocentesis training. Copyright © 2016 The American Physiological Society.

  17. Needle echogenicity in ultrasound-guided lumbar spine injections: a cadaveric study.

    PubMed

    Gofeld, Michael; Krashin, Daniel L; Ahn, Sangmin

    2013-01-01

    Echogenicity of regional anesthesia needles has been tested on different preclinical models; however, previous studies were done in an ideal experimental setting utilizing high-frequency insonation and superficially located targets. Because steep-angle deep injections are typically required for spinal and other chronic pain procedures, and low-frequency transducers are used, further feasibility study is warranted. To determine effectiveness of steep-angle deep injections, typically required for spinal and other chronic pain procedures. Experimental laboratory study. Willed Body Program, University of Washington. In-plane lumbar spine procedures with 50° and 70° angles were performed on a human cadaver. The images and video clips of a non-echogenic (Quincke-type) and echogenic (SonoPlex, StimuQuick, and EchoStim) needle placements were presented to 3 blinded assessors who rated the needle visibility on a 4-point scale. The data was statistically analyzed to determine the differences in visibility between the needles with and without the digital image enhancement, and to compare the video clips to captured images. ANOVA analysis demonstrated that overall SonoPlex was significantly better (P = 0.02) than other needles. SonoPlex maintained its superiority in the subset of facet joint injections (P = 0.02), followed by Quincke-type, then the StimuQuik, and EchoStim needles. In deep procedures, EchoStim was comparable with SonoPlex (P = 0.03), and they both were better than the other 2 needles. The enhanced images received higher rates, with a 0.6 point mean improved rating (P = 0). This study is limited by choice of needles, number of experiments performed, and potential postmortem changes of echogenicity. The SonoPlex needle appeared to have better echogenicity in this study. While non-echogenic Quincke-type needle visibility was adequate in superficial placements, it was limited in deep injections. An imaging enhancement is effective in improving needle visibility

  18. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    PubMed

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  19. Analytical estimation of ultrasound properties, thermal diffusivity, and perfusion using magnetic resonance-guided focused ultrasound temperature data

    PubMed Central

    Dillon, C R; Borasi, G; Payne, A

    2016-01-01

    For thermal modeling to play a significant role in treatment planning, monitoring, and control of magnetic resonance-guided focused ultrasound (MRgFUS) thermal therapies, accurate knowledge of ultrasound and thermal properties is essential. This study develops a new analytical solution for the temperature change observed in MRgFUS which can be used with experimental MR temperature data to provide estimates of the ultrasound initial heating rate, Gaussian beam variance, tissue thermal diffusivity, and Pennes perfusion parameter. Simulations demonstrate that this technique provides accurate and robust property estimates that are independent of the beam size, thermal diffusivity, and perfusion levels in the presence of realistic MR noise. The technique is also demonstrated in vivo using MRgFUS heating data in rabbit back muscle. Errors in property estimates are kept less than 5% by applying a third order Taylor series approximation of the perfusion term and ensuring the ratio of the fitting time (the duration of experimental data utilized for optimization) to the perfusion time constant remains less than one. PMID:26741344

  20. Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT.

    PubMed

    Cheon, Gyeong Woo; Huang, Yong; Kwag, Hye Rin; Kim, Ki-Young; Taylor, Russell H; Gehlbach, Peter L; Kang, Jin U

    2014-01-01

    This paper presents a handheld micro-injector system using common-path swept source optical coherence tomography (CP-SSOCT) as a distal sensor with highly accurate injection-depth-locking. To achieve real-time, highly precise, and intuitive freehand control, the system used graphics processing unit (GPU) to process the oversampled OCT signal with high throughput and a smart customized motion monitoring control algorithm. A performance evaluation was conducted with 60-insertions and fluorescein dye injection tests to show how accurately the system can guide the needle and lock to the target depth. The evaluation tests show our system can guide the injection needle into the desired depth with 4.12 um average deviation error while injecting 50 nl of fluorescein dye.

  1. Image Guidance Technologies for Interventional Pain Procedures: Ultrasound, Fluoroscopy, and CT.

    PubMed

    Wang, Dajie

    2018-01-26

    to fluoroscopy. However, further studies are required to prove the efficacy of ultrasound-guided transforaminal epidural injections. SI joint is unique due to its multiplanar orientation, irregular joint gap, partial ankylosis, and thick dorsal and interosseous ligament. Therefore, it can be difficult to access the joint space with fluoroscopic guidance and ultrasound guidance. CT scan, with its cross-sectional images, can identify posterior joint gap, is most likely the best guidance technology for this intervention. Intercostal nerves lie in the subcostal grove close to the plural space. Significant risk of pneumothorax is associated with intercostal blocks. Ultrasound can provide visualization of ribs and pleura. Therefore, it may improve the accuracy of the injection and reduce the risk of pneumothorax. At present time, most pain specialists are familiar with fluoroscopic guidance techniques, and fluoroscopic machines are readily available in the pain clinics. In the contrast, CT guidance can only be performed in specially equipped facilities. Ultrasound machine is generally portable and inexpensive in comparison to CT scanner and fluoroscopic machine. As pain specialists continue to improve their patient care, ultrasound and CT guidance will undoubtedly be incorporated more into the pain management practice. This review is based on a paucity of clinical evidence to compare these guidance technologies; clearly, more clinical studies is needed to further elucidate the pro and cons of each guidance method for various pain management interventions.

  2. Development of a 3D ultrasound-guided prostate biopsy system

    NASA Astrophysics Data System (ADS)

    Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron

    2007-03-01

    Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.

  3. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    PubMed

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the

  4. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  5. Models to teach lung sonopathology and ultrasound-guided thoracentesis.

    PubMed

    Wojtczak, Jacek A

    2014-12-01

    Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand - eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter's hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.

  6. Novel ultrasound-guided inter-semispinal plane block: a comparative pilot study in healthy volunteers.

    PubMed

    Ohgoshi, Yuichi; Nishizakura, Ryo; Takahashi, Yuki; Takeda, Keisuke; Nakayama, Hirosuke; Kawamata, Mariko; Kurahashi, Kiyoyasu

    2018-02-01

    We previously reported that a novel multifidus cervicis plane (MCP) block could anesthetize the dorsal rami of the cervical spinal nerves. While MCP sonoanatomy is easily detectable in most patients, it is sometimes difficult to recognize the MCP injection plane, especially in elderly patients. Thus, we proposed the inter-semispinal plane (ISP) block as an alternative for the MCP block. The aim of this study was to evaluate the utility of the ISP block by evaluating the area and duration of anesthesia, compared with that of the MCP block in eight healthy volunteers. Each participant underwent unilateral ultrasound-guided MCP block and ISP block. For each block, 20 ml of ropivacaine 0.2% was injected, and the area of anesthesia was determined using the pinprick test. The anesthetic area ranged from C4 to T2 (3/8; 37.5%), T3 (2/8; 25%), or T4 (3/8; 37.5%) in the MCP block, and from C4 to T1 (1/8; 12.5%), T2 (3/8; 37.5%), T3 (2/8; 25%), or T4 (1/8; 12.5%) in the ISP block. The mean (standard deviation) duration of sensory loss following MCP and ISP blocks was 329 (77) min and 349 (70) min, respectively. Thus, the ISP block may be a reliable alternative to the MCP block.

  7. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  8. Ultrasound-guided interventional PDT of liver cancer

    NASA Astrophysics Data System (ADS)

    Zeng, Chaoying; Yang, Dong; Huang, Ping; Zhang, Huijuan; Huang, Muyin; Chen, Ji; Lu, Guorong

    1996-09-01

    Thirty patients with advanced liver cancer were treated by interstitial photodynamic therapy (PDT). These included 28 hepatocellular carcinoma and two adenocarcinoma, 19 primary tumors and 11 recurred follow other treatments. The diameter of tumors were 7-10cm in 13 cases and 10-16cm in 17 cases. In this study, an argon laser pumped dye laser system was used to give a CW laser beam at 630 nm which was split and coupled into there optical fibers. The patients were injected intravenously with photosensitizer hematoporphyrin derivative at a dose of 5mg/kg body weight 48 hours before PDT. Then the fibers were inserted into tumor by ultrasound- guided percutaneous puncture. The inserted irradiation points were spaced in entire tumor with the light release power 300mW and the irradiation time 12 minutes per point. Total 52 treatments were performed in 30 patients. Among them, 14 cases were treated only one time and 16 cases via 2-3 times. The follow-up was carried out in 25 cases for 12- 24 months. The results show that significant remission was 22 percent in those patients by only one treatment and 62 percent in those via 2 to 3 treatments. The shrink rate of tumor size was over 90 percent in five of six cases after treatment 3. The survival time has been over one year in 12 cases. No obvious change to be found for all patients in liver function test, renal function test and blood routine examination. The level of AFP indicated a descending trend after PDT. This work indicate that PDT is effective and safe for the treatment of large liver cancers including those recurred follow hepatic resection and those failed in hepatic artery infusion embolic chemotherapy.

  9. MR-guided pulsed high intensity focused ultrasound enhancement of docetaxel combined with radiotherapy for prostate cancer treatment

    NASA Astrophysics Data System (ADS)

    Mu, Zhaomei; Ma, C.-M.; Chen, Xiaoming; Cvetkovic, Dusica; Pollack, Alan; Chen, Lili

    2012-01-01

    The purpose of this study is to evaluate the efficacy of the enhancement of docetaxel by pulsed focused ultrasound (pFUS) in combination with radiotherapy (RT) for treatment of prostate cancer in vivo. LNCaP cells were grown in the prostates of male nude mice. When the tumors reached a designated volume by MRI, tumor bearing mice were randomly divided into seven groups (n = 5): (1) pFUS alone; (2) RT alone; (3) docetaxel alone; (4) docetaxel + pFUS (5) docetaxel + RT (6) docetaxel + pFUS + RT, and (7) control. MR-guided pFUS treatment was performed using a focused ultrasound treatment system (InSightec ExAblate 2000) with a 1.5T GE MR scanner. Animals were treated once with pFUS, docetaxel, RT or their combinations. Docetaxel was given by i.v. injection at 5 mg kg-1 before pFUS. RT was given 2 Gy after pFUS. Animals were euthanized 4 weeks after treatment. Tumor volumes were measured on MRI at 1 and 4 weeks post-treatment. Results showed that triple combination therapies of docetaxel, pFUS and RT provided the most significant tumor growth inhibition among all groups, which may have potential for the treatment of prostate cancer due to an improved therapeutic ratio.

  10. Injection Therapies for Rotator Cuff Disease.

    PubMed

    Lin, Kenneth M; Wang, Dean; Dines, Joshua S

    2018-04-01

    Rotator cuff disease affects a large proportion of the overall population and encompasses a wide spectrum of pathologies, including subacromial impingement, rotator cuff tendinopathy or tear, and calcific tendinitis. Various injection therapies have been used for the treatment of rotator cuff disease, including corticosteroid, prolotherapy, platelet-rich plasma, stem cells, and ultrasound-guided barbotage for calcific tendinitis. However, the existing evidence for these therapies remains controversial or sparse. Ultimately, improved understanding of the underlying structural and compositional deficiencies of the injured rotator cuff tissue is needed to identify the biological needs that can potentially be targeted with injection therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. User's guide to programming fault injection and data acquisition in the SIFT environment

    NASA Technical Reports Server (NTRS)

    Elks, Carl R.; Green, David F.; Palumbo, Daniel L.

    1987-01-01

    Described are the features, command language, and functional design of the SIFT (Software Implemented Fault Tolerance) fault injection and data acquisition interface software. The document is also intended to assist and guide the SIFT user in defining, developing, and executing SIFT fault injection experiments and the subsequent collection and reduction of that fault injection data. It is also intended to be used in conjunction with the SIFT User's Guide (NASA Technical Memorandum 86289) for reference to SIFT system commands, procedures and functions, and overall guidance in SIFT system programming.

  12. 3D conformal MRI-guided transurethral ultrasound therapy: results of gel phantom experiments

    NASA Astrophysics Data System (ADS)

    N'Djin, W. A.; Burtnyk, M.; McCormick, S.; Bronskill, M.; Chopra, R.

    2011-09-01

    MRI-guided transurethral ultrasound therapy shows promise for minimally invasive treatment of localized prostate cancer. Previous in-vivo studies demonstrated the feasibility of performing conservative treatments using real-time temperature feedback to control accurately the establishment of coagulative lesions within circumscribed prostate regions. This in-vitro study tested device configuration and control options for achieving full prostate treatments. A multi-channel MRI compatible ultrasound therapy system was evaluated in gel phantoms using 3 canine prostate models. Prostate profiles were 5 mm-step-segmented from T2-weighted MR images performed during previous in-vivo experiments. During ultrasound exposures, each ultrasound element was controlled independently by the 3D controller. Decisions on acoustic power, frequency, and device rotation rate were made in real time based on MR thermometry feedback and prostate radii. Low and high power treatment approaches using maximum acoustic powers of 10 or 20 W.cm-2 were tested as well as single and dual-frequency strategies (4.05/13.10 MHz). The dual-frequency strategy used either the fundamental frequency or the 3rd harmonic component, depending on the prostate radius. The 20 W.cm-2 dual frequency approach was the most efficient configuration in achieving full prostate treatments. Treatment times were about half the duration of those performed with 10 W.cm-2 configurations. Full prostate coagulations were performed in 16.3±6.1 min at a rate of 1.8±0.2 cm3.min-1, and resulted in very little undertreated tissue (<3%). Surrounding organs positioned beyond a safety distance of 1.4±1.0 mm from prostate boundaries were not damaged, particularly rectal wall tissues. In this study, a 3D, MR-thermometry-guided transurethral ultrasound therapy was validated in vitro in a tissue-mimicking phantom for performing full prostate treatment. A dual-frequency configuration with 20 W.cm-2 ultrasound intensity exposure showed good

  13. Primary malignant tumours of the bony pelvis: US-guided high intensity focused ultrasound ablation.

    PubMed

    Wang, Yang; Wang, Wei; Tang, Jie

    2013-11-01

    The aim of this review is to evaluate the value of ultrasound (US)-guided high intensity focused ultrasound (HIFU) ablation in the treatment of primary malignant tumours of the bony pelvis. Eleven patients with primary malignant tumours of the bony pelvis received US-guided HIFU ablation. The maximum tumour size ranged from 5.6 to 25.0 cm (median 10.5 cm). Treatment was curative in four patients and palliative in seven patients. During follow-up, the effectiveness of HIFU ablation was assessed by contrast-enhanced magnetic resonance (MR). Significant coagulative necrosis was obtained in all patients after scheduled HIFU ablations; the volume ablation ratio was 86.7% ± 12.5% (range 65-100%). Complete tumour necrosis was achieved in all patients receiving curative HIFU ablation. No major complications were encountered. No patients died of local tumour progression during follow-up. US-guided HIFU ablation may be a safe and effective minimally invasive technique for the local treatment of primary malignant tumours of the bony pelvis.

  14. Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis

    PubMed Central

    Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao

    2013-01-01

    AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631

  15. Opening the Blood-Brain Barrier with MR Imaging-guided Focused Ultrasound: Preclinical Testing on a Trans-Human Skull Porcine Model.

    PubMed

    Huang, Yuexi; Alkins, Ryan; Schwartz, Michael L; Hynynen, Kullervo

    2017-01-01

    Purpose To develop and test a protocol in preparation for a clinical trial on opening the blood-brain barrier (BBB) with magnetic resonance (MR) imaging-guided focused ultrasound for the delivery of chemotherapy drugs to brain tumors. Materials and Methods The procedures were approved by the institutional animal care committee. A trans-human skull porcine model was designed for the preclinical testing. Wide craniotomies were applied in 11 pigs (weight, approximately 15 kg). A partial human skull was positioned over the animal's brain. A modified clinical MR imaging-guided focused ultrasound brain system was used with a 3.0-T MR unit. The ultrasound beam was steered during sonications over a 3 × 3 grid at 3-mm spacing. Acoustic power levels of 3-20 W were tested. Bolus injections of microbubbles at 4 μL/kg were tested for each sonication. Levels of BBB opening, hemorrhage, and cavitation signal were measured with MR imaging, histologic examination, and cavitation receivers, respectively. A cavitation safety algorithm was developed on the basis of logistic regression of the measurements and tested to minimize the risk of hemorrhage. Results BBB openings of approximately 1 cm 3 in volume were visualized with gadolinium-enhanced MR imaging after sonication at an acoustic power of approximately 5 W. Gross examination of histologic specimens helped confirm Evans blue (bound to macromolecule albumin) extravasation, and hematoxylin-eosin staining helped detect only scattered extravasation of red blood cells. In cases where cavitation signals were higher than thresholds, sonications were terminated immediately without causing hemorrhage. Conclusion With a trans-human skull porcine model, this study demonstrated BBB opening with a 230-kHz system in preparation for a clinical trial. © RSNA, 2016 Online supplemental material is available for this article.

  16. Ultrasound Guidance for Botulinum Neurotoxin Chemodenervation Procedures.

    PubMed

    Alter, Katharine E; Karp, Barbara I

    2017-12-28

    Injections of botulinum neurotoxins (BoNTs) are prescribed by clinicians for a variety of disorders that cause over-activity of muscles; glands; pain and other structures. Accurately targeting the structure for injection is one of the principle goals when performing BoNTs procedures. Traditionally; injections have been guided by anatomic landmarks; palpation; range of motion; electromyography or electrical stimulation. Ultrasound (US) based imaging based guidance overcomes some of the limitations of traditional techniques. US and/or US combined with traditional guidance techniques is utilized and or recommended by many expert clinicians; authors and in practice guidelines by professional academies. This article reviews the advantages and disadvantages of available guidance techniques including US as well as technical aspects of US guidance and a focused literature review related to US guidance for chemodenervation procedures including BoNTs injection.

  17. High volume image-guided Injections for patellar tendinopathy: a combined retrospective and prospective case series.

    PubMed

    Morton, Sarah; Chan, Otto; King, John; Perry, David; Crisp, Tom; Maffulli, Nicola; Morrissey, Dylan

    2014-04-01

    the aim was to quantify the effect of a novel high volume-image guided injection (HVIGI) technique for recalcitrant patellar tendinopathy (PT). twenty patients (8 prospective; 12 retrospective) with ultrasonographically confirmed proximal PT were recruited. A HVIGI under ultra-sound guidance of 10 ml 0.5% Bupivacaine, 25 mg Hydrocortisone and 30 ml normal saline at the interface of the patellar tendon and Hoffa's fat pad was administered. A standardised eccentric loading rehabilitation protocol was prescribed. the VISA-P score improved from 45.0 to 64.0 (p<0.01) for all subjects, likely to be clinically significant. There was no statistically significant difference between the increase in the retrospective group of 19.9 (± 23.5) and the prospective of 16.4 (± 11.3) p = 0.7262.5% of prospective subjects agreed that they had significantly improved, with 37.5% returning to sport within 12 weeks. HVIGI should be considered in the management of recalcitrant PT. Randomised controlled trials are warranted.

  18. Ultrasound guided transarterial coil placement in the internal and external carotid artery in horses.

    PubMed

    Muñoz, Juan; Iglesias, Manuel; Chao, Eduardo Lloret; Bussy, Christian

    2015-04-01

    To assess ultrasound guided transarterial coil placement (UGTACP) for occlusion of the internal carotid artery (ICA) and external carotid artery (ECA) in horses. Cadaveric and in vivo study. Cadaveric horses (n = 10), healthy horses (3), and 1 clinical case. Cadaveric and in vivo (healthy horses): UGTACP was performed in the caudal part of the ICA and ECA. Coil placement in the rostral part of the ICA was performed blindly and controlled by conventional radiography. No coils were placed in the rostral part of the ECA. UGTACP of the ICA was in a horse with guttural pouch mycosis of the left guttural pouch. Accurate ultrasound-guided catheterization of the ICA and ECA was performed in all specimens. Ultrasound-guided coil placement was successfully performed in all cases except 1. No complications occurred in the in vivo study. The clinical case fully recovered and returned to its intended use. Based on our study, UGTACP of the ICA and ECA caudal part is a feasible alternative to fluoroscopy. An advantage of this technique is the accuracy with which you can catheterize both ICA and ECA and the ability to identify unusual branching at the origin of the ICA. Regarding the rostral part of the ICA, angiographic catheter guidance in this region is probably more precise using fluoroscopy as it is performed blindly. In a clinical situation, combination of US and fluoroscopy guidance can result in reduction of radiation exposure time. © Copyright 2014 by The American College of Veterinary Surgeons.

  19. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    PubMed

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  20. Prospective randomized trial comparing magnetic resonance imaging (MRI)-guided in-bore biopsy to MRI-ultrasound fusion and transrectal ultrasound-guided prostate biopsy in patients with prior negative biopsies.

    PubMed

    Arsov, Christian; Rabenalt, Robert; Blondin, Dirk; Quentin, Michael; Hiester, Andreas; Godehardt, Erhard; Gabbert, Helmut E; Becker, Nikolaus; Antoch, Gerald; Albers, Peter; Schimmöller, Lars

    2015-10-01

    A significant proportion of prostate cancers (PCas) are missed by conventional transrectal ultrasound-guided biopsy (TRUS-GB). It remains unclear whether the combined approach using targeted magnetic resonance imaging (MRI)-ultrasound fusion-guided biopsy (FUS-GB) and systematic TRUS-GB is superior to targeted MRI-guided in-bore biopsy (IB-GB) for PCa detection. To compare PCa detection between IB-GB alone and FUS-GB + TRUS-GB in patients with at least one negative TRUS-GB and prostate-specific antigen ≥4 ng/ml. Patients were prospectively randomized after multiparametric prostate MRI to IB-GB (arm A) or FUS-GB + TRUS-GB (arm B) from November 2011 to July 2014. The study was powered at 80% to demonstrate an overall PCa detection rate of ≥60% in arm B compared to 40% in arm A. Secondary endpoints were the distribution of highest Gleason scores, the rate of detection of significant PCa (Gleason ≥7), the number of biopsy cores to detect one (significant) PCa, the positivity rate for biopsy cores, and tumor involvement per biopsy core. The study was halted after interim analysis because the primary endpoint was not met. The trial enrolled 267 patients, of whom 210 were analyzed (106 randomized to arm A and 104 to arm B). PCa detection was 37% in arm A and 39% in arm B (95% confidence interval for difference, -16% to 11%; p=0.7). Detection rates for significant PCa (29% vs 32%; p=0.7) and the highest percentage tumor involvement per biopsy core (48% vs 42%; p=0.4) were similar between the arms. The mean number of cores was 5.6 versus 17 (p<0.001). A limitation is the limited number of patients because of early cessation of accrual. This trial failed to identify an important improvement in detection rate for the combined biopsy approach over MRI-targeted biopsy alone. A prospective comparison between MRI-targeted biopsy alone and systematic TRUS-GB is justified. Our randomized study showed similar prostate cancer detection rates between targeted prostate biopsy

  1. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    PubMed

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  2. First noninvasive thermal ablation of a brain tumor with MR-guided focused ultrasound

    PubMed Central

    2014-01-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas its clinical application for tumor neurosurgery has been delayed for various technical and procedural reasons. Here, we report the case of a 63-year-old patient presenting with a centrally located recurrent glioblastoma who was included in our ongoing clinical phase I study aimed at evaluating the feasibility and safety of transcranial MRgFUS for brain tumor ablation. Applying 25 high-power sonications under MR imaging guidance, partial tumor ablation could be achieved without provoking neurological deficits or other adverse effects in the patient. This proves, for the first time, the feasibility of using transcranial MR-guided focused ultrasound to safely ablate substantial volumes of brain tumor tissue. PMID:25671132

  3. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    PubMed

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-06-01

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p < 0.001]. No difference was seen in time to cannulate [SMD (95% CI) -0.31 (-0.65, 0.04); p = 0.30] and mean number of attempt [MD (95% CI) -0.65 (-1.32, 0.02); p = 0.06] between USG guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of

  4. Real-time ultrasound-guided PCNL using a novel SonixGPS needle tracking system.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; Dalin, He; He, Hui

    2014-08-01

    SonixGPS is a successful ultrasound guidance position system. It helps to improve accuracy in performing complex puncture operations. This study firstly used SonixGPS to perform kidney calyx access in PCNL to investigate its effectiveness and safety. This was a prospectively randomized controlled study performed from September 2011 to October 2012. A total of 97 patients were prospectively randomized into two groups using random number generated from SAS software. 47 Patients were enrolled in conventional ultrasound-guided (US-guided) group and 50 patients were classified into SonixGPS-guided group. Nine patients were lost during follow-up. Hence, a total of 88 patients were qualified and analyzed. Preoperative examinations included urine analysis, urine culture, kidney function, coagulation profile and routine analysis of blood. Ultrasonography was used to evaluate the degree of hydronephrosis. The intraoperative findings, including blood loss, operating time, time to successful puncture, the number of attempts for successful puncture and hospital stay were recorded. The stone clearance rate and complications were analyzed. The present study showed no significant difference between the two groups in terms of demographic data, preoperative markers, stone clearance rate and the stone composition. However, the time to successful puncture, the number of trials for successful puncture, operating time and hospital length of stay were significantly decreased in the SonixGPS-guided group. Furthermore, the hemoglobin decrease was also obviously lower in the SonixGPS group than that in conventional US-guided group. SonixGPS needle tacking system guided PCNL is safe and effective in treating upper urinary tract stones. This novel technology makes puncturing more accuracy and can significantly decrease the incidence of relative hemorrhage and accelerate recovery.

  5. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    PubMed

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  6. Pathological fracture of the patella due to an atypical located aneurysmal bone cyst: verification by means of ultrasound-guided biopsy.

    PubMed

    Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander

    2016-03-01

    We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.

  7. Ultrasound-guided drainages and sclerotherapy.

    PubMed

    Lohela, P

    2002-02-01

    Ultrasonically guided fluid collection and abscess drainage have become routine procedures in various parts of the body. In most cases ultrasound is the only imaging and guidance modality needed; however, it is of the utmost importance to remember that CT and fluoroscopy with contrast often give invaluable information when the true extent of the process has to be determined and when assessing the safest route for the catheter in anatomically complicated areas. The importance of irrigation of the abscess cavity with fluids and the ready use of urokinase should be emphasized. Ethanol sclerotherapy is a simple and safe procedure to treat symptomatic hepatic or renal cysts. Parathyroid adenomas and cysts, as well as thyroid cysts, can also be treated with ethanol sclerotherapy in selected cases. Purified mineral talc has been used in pleurodesis and hydrocele sclerotherapy, whereas doxycycline or ethanol is used for postoperative lymphoceles. Both abscess drainages and sclerotherapy procedures are minimally invasive, simple, safe, inexpensive and reasonably efficacious treatment in many clinical instances and may be at least an alternative to surgical treatment, often offering significant advantages over surgery.

  8. MRI-Guided Focused Ultrasound Surgery

    PubMed Central

    Jolesz, Ferenc A.

    2014-01-01

    MRI-guided focused ultrasound (MRgFUS) surgery is a noninvasive thermal ablation method that uses magnetic resonance imaging (MRI) for target definition, treatment planning, and closed-loop control of energy deposition. Integrating FUS and MRI as a therapy delivery system allows us to localize, target, and monitor in real time, and thus to ablate targeted tissue without damaging normal structures. This precision makes MRgFUS an attractive alternative to surgical resection or radiation therapy of benign and malignant tumors. Already approved for the treatment of uterine fibroids, MRgFUS is in ongoing clinical trials for the treatment of breast, liver, prostate, and brain cancer and for the palliation of pain in bone metastasis. In addition to thermal ablation, FUS, with or without the use of microbubbles, can temporarily change vascular or cell membrane permeability and release or activate various compounds for targeted drug delivery or gene therapy. A disruptive technology, MRgFUS provides new therapeutic approaches and may cause major changes in patient management and several medical disciplines. PMID:19630579

  9. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    PubMed

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Acute Calcific Bursitis After Ultrasound-Guided Percutaneous Barbotage of Rotator Cuff Calcific Tendinopathy: A Case Report.

    PubMed

    Kang, Bo-Sung; Lee, Seung Hak; Cho, Yung; Chung, Sun Gun

    2016-08-01

    Ultrasound-guided percutaneous barbotage is an effective treatment for rotator cuff calcific tendinopathy, providing rapid and substantial pain relief. We present the case of a 49-year-old woman with aggravated pain early after ultrasound-guided barbotage of a large calcific deposit in the supraspinatus tendon. Subsequent examination revealed a thick calcification spreading along the subacromial-subdeltoid bursa space, suggesting acute calcific bursitis complicated by barbotage. Additional barbotage alleviated her pain completely. Therefore, a high index of suspicion for acute calcific bursitis is required in patients with unresolved or aggravated pain after barbotage. Repeated barbotage could be effective for this condition. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  11. Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.

    PubMed

    Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman

    2013-10-01

    Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.

  12. Update on Clinical MR-guided Focused Ultrasound Applications

    PubMed Central

    McDannold, Nathan

    2015-01-01

    SYNOPSIS Focused ultrasound (FUS) can be used to thermally ablate tissue. The performance of FUS under magnetic resonance (MR) guidance enables aiming the focus at the target, accurate treatment planning, real-time temperature mapping, and evaluation of the treatment. This review updates several clinical applications of MR-guided FUS. MR-guided FUS has a CE mark and FDA approval for thermal ablation for uterine fibroids and bone metastases related pain management. Thousands of uterine fibroid patients have successfully been treated with minor side effects. Technical improvements, increased experience, and the use of a screening MRI examination should further improve treatment outcome. When used for bone metastases and other bone diseases, thermal ablation leads to pain relief due to denervation, and debulking of the tumor. The use of a hemi-spherical multi-element transducer and phase corrections have enabled application of FUS through the skull. Transcranial MR-guided FUS has received CE certification for ablation of deep, central locations in the brain such as the thalamus. Thermal ablation of specific parts of the thalamus can result in relief of the symptoms in neurological disorders such as essential tremor, Parkinson’s, and neuropathic pain. No CE mark or FDA approval has been obtained as yet for treatment of prostate cancer or breast cancer, but several approaches have been proposed and clinical trials should show the potential of MR-guided FUS for these and other applications. PMID:26499282

  13. Effect of abdominal liposuction on sonographically guided high-intensity focused ultrasound ablation.

    PubMed

    Zhao, Wen-Peng; Chen, Jin-Yun; Chen, Wen-Zhi

    2014-09-01

    The aim of this study was to evaluate the effect of abdominal liposuction on sonographically guided high-intensity focused ultrasound (HIFU) ablation. A total of 10 women with uterine fibroids or adenomyosis who had received abdominal liposuction were analyzed after sonographically guided HIFU ablation. Of the 10 women, 6 had a diagnosis of uterine fibroids, and 4 had a diagnosis of uterine adenomyosis. All of them had a history of a horizontal-margin split-cesarean delivery. In addition, 26 women with a history of a single horizontal-margin split-cesarean delivery who had a diagnosis of uterine fibroids or adenomyosis but had not received liposuction were analyzed together as a control group. Of the 10 women, 1 woman with uterine fibroids developed local skin erythema after treatment; 1 women with uterine adenomyosis developed a skin burn after treatment; and the remaining women had obvious skin-burning pain during treatment. All women who had not received liposuction finished the treatment with no serious adverse events during or after treatment. The pain scores and incidence of skin-burning pain were significantly higher in the liposuction group than the control group (P= .021 and .038, respectively). Abdominal liposuction may increase the risk of skin burns during sonographically guided HIFU ablation. © 2014 by the American Institute of Ultrasound in Medicine.

  14. Defining the reliability of sonoanatomy identification by novices in ultrasound-guided pediatric ilioinguinal and iliohypogastric nerve blockade.

    PubMed

    Ford, Simon; Dosani, Maryam; Robinson, Ashley J; Campbell, G Claire; Ansermino, J Mark; Lim, Joanne; Lauder, Gillian R

    2009-12-01

    The ilioinguinal (II)/iliohypogastric (IH) nerve block is a safe, frequently used block that has been improved in efficacy and safety by the use of ultrasound guidance. We assessed the frequency with which pediatric anesthesiologists with limited experience with ultrasound-guided regional anesthesia could correctly identify anatomical structures within the inguinal region. Our primary outcome was to compare the frequency of correct identification of the transversus abdominis (TA) muscle with the frequency of correct identification of the II/IH nerves. We used 2 ultrasound machines with different capabilities to assess a potential equipment effect on success of structure identification and time taken for structure identification. Seven pediatric anesthesiologists with <6 mo experience with ultrasound-guided regional anesthesia performed a total of 127 scans of the II region in anesthetized children. The muscle planes and the II and IH nerves were identified and labeled. The ultrasound images were reviewed by a blinded expert to mark accuracy of structure identification and time taken for identification. Two ultrasound machines (Sonosite C180plus and Micromaxx, both from Sonosite, Bothell, WA) were used. There was no difference in the frequency of correct identification of the TA muscle compared with the II/IH nerves (chi(2) test, TA versus II, P = 0.45; TA versus IH, P = 0.50). Ultrasound machine selection did show a nonsignificant trend in improving correct II/IH nerve identification (II nerve chi(2) test, P = 0.02; IH nerve chi(2) test, P = 0.04; Bonferroni corrected significance 0.17) but not for the muscle planes (chi(2) test, P = 0.83) or time taken (1-way analysis of variance, P = 0.07). A curve of improving accuracy with number of scans was plotted, with reliability of TA recognition occurring after 14-15 scans and II/IH identification after 18 scans. We have demonstrated that although there is no difference in the overall accuracy of muscle plane versus II

  15. Effect of Low-Intensity Pulsed Ultrasound after Mesenchymal Stromal Cell Injection to Treat Osteochondral Defects: An In Vivo Study.

    PubMed

    Yamaguchi, Shoki; Aoyama, Tomoki; Ito, Akira; Nagai, Momoko; Iijima, Hirotaka; Tajino, Junichi; Zhang, Xiangkai; Wataru, Kiyan; Kuroki, Hiroshi

    2016-12-01

    We investigated the effect of low-intensity pulsed ultrasound (LIPUS) treatment combined with mesenchymal stromal cell (MSC) injection for cartilage repair and subchondral bone reconstitution for treatment of osteochondral defects. An osteochondral defect was created on both femur grooves of Wistar rats. Four weeks later, bone marrow MSCs were injected into the right knee joint. The rats were divided into two intervention groups: without or with LIPUS irradiation. Cartilage repair was evaluated histologically based on the Wakitani cartilage repair score. Subchondral bone reconstitution was evaluated as bone volume (BV)/tissue volume (TV) by micro-computed tomography analysis. MSC injection improved the cartilage repair score, and LIPUS irradiation improved BV/TV. Combination treatment promoted both cartilage repair and BV/TV improvement. Thus, MSC injection combined with LIPUS irradiation is more effective than either treatment alone in promoting concurrent cartilage repair and subchondral reconstitution. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    NASA Astrophysics Data System (ADS)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  17. An orthopedist's guide to shoulder ultrasound: a systematic review of examination protocols.

    PubMed

    Amoo-Achampong, Kelms; Nwachukwu, Benedict U; McCormick, Frank

    2016-11-01

    The utilization of musculoskeletal ultrasound has expanded within the setting of the orthopedic clinic as a cost-effective, point-of-care diagnostic tool for shoulder pathology. In experienced hands, ultrasound exhibits capabilities equivalent to that of magnetic resonance imaging in the diagnosis of many shoulder diseases including full-thickness and partial-thickness rotator cuff tears. Although similarly effective in identifying additional shoulder disease processes, major obstacles to its widespread use include user dependence and intrinsic limitation to extra-articular diagnosis. The purpose of this review is to present a step-by-step guide of how to perform a comprehensive shoulder examination and to discuss the appropriate use, economic benefit and implementation of ultrasound within the clinic. A systematic search (June 2016) of PubMed, Scopus, and EMBASE databases was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for literature presenting shoulder ultrasound examination protocols. Included studies were peer-reviewed articles or academic society endorsed protocols presenting comprehensive sonographic examinations of the adult shoulder. Papers with limited or single structure examination descriptions, non-English language, and publication dates before 1980 were excluded. Final papers meeting criteria were secondarily screened for publication after 2005 to reflect the current state of ultrasound imaging. The search yielded 1,725 unique articles with 17 studies meeting final selection criteria. Information from identified studies was summarized to formulate a 4-part shoulder examination protocol, including steps most pertinent to orthopedic in-office diagnoses. In agreement with previous studies, the inexperienced orthopedic surgeon can be quickly trained to expert level proficiency in shoulder ultrasound diagnosis. Using an established protocol, a comprehensive, yet effective shoulder

  18. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    García-Medina, J., E-mail: josegmedina57@gmail.com; García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance ismore » feasible and safe in roughly two-thirds of cases.« less

  19. Theoretical Analysis of the Accuracy and Safety of MRI-Guided Transurethral 3-D Conformal Ultrasound Prostate Therapy

    NASA Astrophysics Data System (ADS)

    Burtnyk, Mathieu; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound therapy is a promising new approach for the treatment of localized prostate cancer. Several studies have demonstrated the feasibility of producing large regions of thermal coagulation adequate for prostate therapy; however, the quantitative assessment of shaping these regions to complex 3-D human prostate geometries has not been fully explored. This study used numerical simulations and twenty manually-segmented pelvic anatomical models derived from high-quality MR images of prostate cancer patients to evaluate the treatment accuracy and safety of 3-D conformal MRI-guided transurethral ultrasound therapy. The simulations incorporated a rotating multi-element planar dual-frequency ultrasound transducer (seventeen 4×3 mm elements) operating at 4.7/9.7 MHz and 10 W/cm2 maximum acoustic power. Results using a novel feedback control algorithm which modulated the ultrasound frequency, power and device rate of rotation showed that regions of thermal coagulation could be shaped to predefined prostate volumes within 1.0 mm across the vast majority of these glands. Treatment times were typically 30 min and remained below 60 min for large 60 cc prostates. With a rectal cooling temperature of 15° C, the rectal wall did not exceed 30EM43 in half of the twenty patient models with only a few 1 mm3 voxels above this threshold in the other cases. At 4.7 MHz, heating of the pelvic bone can become significant when it is located less than 10 mm from the prostate. Numerical simulations show that MRI-guided transurethral ultrasound therapy can thermally coagulate whole prostate glands accurately and safely in 3-D.

  20. Perspectives in ultrasound-guided musculoskeletal interventions

    PubMed Central

    Daftary, Aditya Ravindra; Karnik, Alpana Sudhir

    2015-01-01

    Ultrasonography (USG) is a safe, easily available, and cost-effective modality, which has the additional advantage of being real time for imaging and image-guided interventions of the musculoskeletal system. Musculoskeletal interventions are gaining popularity in sports and rehabilitation for rapid healing of muscle and tendon injuries in professional athletes, healing of chronic tendinopathies, aspiration of joint effusions, periarticular bursae and ganglia, and perineural injections in acute and chronic pain syndromes. This article aims to provide an overview of the spectrum of musculoskeletal interventions that can be done under USG guidance both for diagnostic and therapeutic purposes. PMID:26288519

  1. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.

    PubMed

    Baez, E; Huber, A; Vetter, M; Hackelöer, B-J

    2003-03-01

    The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are ultrasound offers the advantage of better preoperative demonstration of the lesions' margins, resulting in better assessment of volumetry, improved intraoperative needle location and perioperative

  2. Ultrasound in regional anaesthesia.

    PubMed

    Griffin, J; Nicholls, B

    2010-04-01

    Ultrasound guidance is rapidly becoming the gold standard for regional anaesthesia. There is an ever growing weight of evidence, matched with improving technology, to show that the use of ultrasound has significant benefits over conventional techniques, such as nerve stimulation and loss of resistance. The improved safety and efficacy that ultrasound brings to regional anaesthesia will help promote its use and realise the benefits that regional anaesthesia has over general anaesthesia, such as decreased morbidity and mortality, superior postoperative analgesia, cost-effectiveness, decreased postoperative complications and an improved postoperative course. In this review we consider the evidence behind the improved safety and efficacy of ultrasound-guided regional anaesthesia, before discussing its use in pain medicine, paediatrics and in the facilitation of neuraxial blockade. The Achilles' heel of ultrasound-guided regional anaesthesia is that anaesthetists are far more familiar with providing general anaesthesia, which in most cases requires skills that are achieved faster and more reliably. To this ends we go on to provide practical advice on ultrasound-guided techniques and the introduction of ultrasound into a department.

  3. Point-of-care ultrasound diagnosis and treatment of posterior shoulder dislocation.

    PubMed

    Beck, Sierra; Chilstrom, Mikaela

    2013-02-01

    Acute traumatic posterior shoulder dislocations are rare. The diagnosis is often missed or delayed, as radiologic abnormalities can be subtle. We report a case of a 37-year-old man who presented to the emergency department with severe right shoulder pain and inability to move his arm after a motor vehicle collision. Based on examination, he was initially thought to have an anterior dislocation; however, point-of-care (POC) ultrasound clearly demonstrated a posterior shoulder dislocation. Real-time ultrasound-guided intra-articular local anesthetic injection facilitated closed reduction in the emergency department without procedural sedation, and POC ultrasound confirmed successful reduction at the bedside after the procedure. This case demonstrates that POC ultrasound can be a useful diagnostic tool in the rapid assessment and treatment for patients with suspected posterior shoulder dislocation. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    PubMed

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  5. Influence of transvaginal ultrasound-guided follicular punctures in the mare on heart rate, respiratory rate, facial expression changes, and salivary cortisol as pain scoring.

    PubMed

    Diego, Rodrigo; Douet, Cécile; Reigner, Fabrice; Blard, Thierry; Cognié, Juliette; Deleuze, Stefan; Goudet, Ghylène

    2016-10-15

    Transvaginal ultrasound-guided follicular punctures are widely used in the mare for diagnosis, research, and commercial applications. The objective of our study was to determine their influence on pain, stress, and well-being in the mare, by evaluating heart rate, breath rate, facial expression changes, and salivary cortisol before, during, and after puncture. For this experiment, 21 pony mares were used. Transvaginal ultrasound-guided aspirations were performed on 11 mares. After injections for sedation, analgesia, and antispasmodia, the follicles from both ovaries were aspirated with a needle introduced through the vagina wall into the ovary. In the control group, 10 mares underwent similar treatments and injections, but no follicular aspiration. Along the session, heart rate and breath rate were evaluated by a trained veterinarian, ears position, eyelid closure, and contraction of facial muscles were evaluated, and salivary samples were taken for evaluation of cortisol concentration. A significant relaxation was observed after sedative injection in the punctured and control mares, according to ear position, eyelid closure, and contraction of facial muscles, but no difference between punctured and control animals was recorded. No significant modification of salivary cortisol concentration during puncture and no difference between punctured and control mares at any time were observed. No significant modification of the breath rate was observed along the procedure for the punctured and the control mares. Heart rate increased significantly but transiently when the needle was introduced in the ovary and was significantly higher at that time for the punctured mares than that for control mares. None of the other investigated parameters were affected at that time, suggesting discomfort is minimal and transient. Improving analgesia, e.g., through a multimodal approach, during that possibly more sensitive step could be recommended. The evaluation of facial expression

  6. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    PubMed

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  7. Measuring the potency labelling of onabotulinumtoxinA (Botox(®)) and incobotulinumtoxinA (Xeomin (®)) in an LD50 assay.

    PubMed

    Dressler, Dirk; Mander, Gerd; Fink, Klaus

    2012-01-01

    The biological potency of botulinum toxin (BT) drugs is determined by a standardised LD50 assay. However, the potency labelling varies vary amongst different BT drugs. One reason for this may be differences in the LD50 assays applied. When five unexpired batches of onabotulinumtoxinA (Botox(®)) and incobotulinumtoxinA (Xeomin(®)) are compared in the Xeomin(®) batch release assay, the potency variability of both BT drugs fell within the range allowed by the European Pharmacopoiea. Statistical analyses failed to detect differences in the potency labelling of both products. Although the existence of a conversion ratio has been questioned recently, our experimental data are in line with previous clinical experience showing that Botox(®) and Xeomin(®) can be compared using a 1:1 conversion ratio. Identical potency labelling allows easy exchange of both BT drugs in a therapeutic setting, and direct comparison of efficacy, adverse effects and costs.

  8. The effect of morphine added to bupivacaine in ultrasound guided transversus abdominis plane (TAP) block for postoperative analgesia following lower abdominal cancer surgery, a randomized controlled study.

    PubMed

    El Sherif, Fatma Adel; Mohamed, Sahar Abdel-Baky; Kamal, Shereen Mamdouh

    2017-06-01

    Transversus abdominis plane (TAP) block used for management of surgical abdominal pain by injecting local anesthetics into the plane between the internal oblique and transversus abdominis muscles. We aimed to explore the effect of adding morphine to bupivacaine in ultrasound guided TAP-block in patients undergoing lower abdominal cancer surgery. Randomized, double-blind, prospective study. Clinical trial identifier: NCT02566096. Academic medical center. Sixty patients were enrolled in this study after ethical committee approval. Patients divided into 2 groups (30 each): Bupivacaine group (GB): given ultrasound guided TAP-block 20ml 0.5% bupivacaine diluted in 20ml saline; Morphine group (GM): given ultrasound guided TAP-block with 20ml 0.5% bupivacaine+10mg morphine sulphate diluted in 20ml saline. Patients were observed for total morphine consumption, time for first request of rescue analgesia, sedation scores, hemodynamics and side effects for 24h postoperatively. Morphine added to bupivacaine in TAP block compared to bupivacaine alone reduced total morphine consumption (5.33±1.28mg) (10.70±3.09mg) respectively (p<0.001), prolonged the time to first request of analgesia (10.40±4.96h) (6.97±3.26h) respectively (p<0.008), with a statistically significant decrease in (VAS-M) in GM compared with GB at 12h postoperatively (p<0.002). No significant differences in hemodynamics, respiratory rate, oxygen saturation, sedation score, and side effects except for nausea were observed (p>0.05). Addition of morphine to bupivacaine in TAP block is effective method for pain management in patients undergoing major abdominal cancer surgery without serious side effects. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Clinical effects of image-guided hyaluronate injections for the osteochondral lesions of ankle in sport active population.

    PubMed

    DI Gesù, Marco; Fusco, Augusto; Vetro, Angelo; Iosa, Marco; Mantia, Fabrizio; Iovane, Angelo; Mantia, Roberto

    2016-11-01

    Hyaluronic acid injections are effective as intra-articular treatment, but their use in the ankle has been hindered for the difficulty of execution in this area. Use of a guidance of musculo-skeleletal ultrasound could improve the success rate and the subsequent clinical outcome, for the ameliorating placement of the needle tip. The aim of this pilot study was to assess the short-term efficacy in terms of functional outcomes and pain of a image-guided intra-articular hyaluronic acid injections of post-traumatic osteochondral lesions (OLs) of the ankle. Thirty sport active patients (21 males; mean age 27.6±7.46) with a clinical and radiological diagnosis of post-traumatic ankle OLs at initial stage, received a course of three injections within a month. Patients were evaluated for pain (with Numerical Rating Scale, NRS) e function (Ankle-Hindfoot Scale, AHS, and range of motion, ROM) before every injection and ninety days after the last injection (T0-T3). Pain showed a significant and clinically relevant improvement during the period of treatment (P<0.001), even if pain was still presented at last follow-up assessment. Also for AHS e ROM, it was recorded a similar positive trend during time (P<0.001 for both measurements). Before intervention, pain and function resulted correlated (P<0.001), while at follow-up assessment these correlations were reduced, remaining only between pain at rest and plantar-flexion range. These results showed positive effects of the intra-articular hyaluronic acid for the osteochondral lesions, with a full recovery of the functional activity and a significant reduction of pain.

  10. Changes in B-mode ultrasound echo intensity following injection of bupivacaine hydrochloride to rat hind limb muscles in relation to histologic changes.

    PubMed

    Fujikake, T; Hart, R; Nosaka, Kazunori

    2009-04-01

    This study tested the hypothesis that infiltration of inflammatory cells in muscle fibers would increase echo intensity (image brightness) of B-mode ultrasound images. Bupivacaine hydrochloride (BPVC) or saline solution (SAL) was injected to the tibialis anterior (TA) muscles of 14- to 23-wk-old male Wistar rats. Ultrasound images were taken from the muscles before and at 0, 2, 4, 6, 9, 12, 24, 48, 72, 120, 168 and 336 h after the injection and analyzed for the echo intensity (echogenicity) expressed as the mean value of image pixel value of a region-of-interest. Changes in the echo intensity were compared between BPVC-injected and control or SAL-injected muscles. In the subsequent study, rats (n = 2 per time point) were sacrificed after taking ultrasound image at 0, 2, 6, 12, 24, 48 and 168 h after BPVC injection to the right TA and SAL injection to the left TA to observe histologic changes under a light microscope and the relationship between echo intensity and inflammatory cells was assessed. No significant changes in echo intensity were observed for the control, but BPVC induced significant (p < 0.05) increases in the echo intensity peaking 0 to 24 h postinjection. SAL also increased echo intensity immediately after injection but returned to the baseline by 24 h postinjection. The time course of changes in the echo intensity did not match with the time course of increases in inflammatory cells in the muscle. It is concluded that infiltration of inflammatory cells is not a direct cause of the increased echo intensity.

  11. A new diagnostic approach to popliteal artery entrapment syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Charles; Kennedy, Dominic; Bastian-Jordan, Matthew

    A new method of diagnosing and defining functional popliteal artery entrapment syndrome is described. By combining ultrasonography and magnetic resonance imaging techniques with dynamic plantarflexion of the ankle against resistance, functional entrapment can be demonstrated and the location of the arterial occlusion identified. This combination of imaging modalities will also define muscular anatomy for guiding intervention such as surgery or Botox injection.

  12. Thermal fixation of swine liver tissue after magnetic resonance-guided high-intensity focused ultrasound ablation.

    PubMed

    Courivaud, Frédéric; Kazaryan, Airazat M; Lund, Alice; Orszagh, Vivian C; Svindland, Aud; Marangos, Irina Pavlik; Halvorsen, Per Steinar; Jebsen, Peter; Fosse, Erik; Hol, Per Kristian; Edwin, Bjørn

    2014-07-01

    The aim of this study was to investigate experimental conditions for efficient and controlled in vivo liver tissue ablation by magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) in a swine model, with the ultimate goal of improving clinical treatment outcome. Histological changes were examined both acutely (four animals) and 1 wk after treatment (five animals). Effects of acoustic power and multiple sonication cycles were investigated. There was good correlation between target size and observed ablation size by thermal dose calculation, post-procedural MR imaging and histopathology, when temperature at the focal point was kept below 90°C. Structural histopathology investigations revealed tissue thermal fixation in ablated regions. In the presence of cavitation, mechanical tissue destruction occurred, resulting in an ablation larger than the target. Complete extra-corporeal MR-guided HIFU ablation in the liver is feasible using high acoustic power. Nearby large vessels were preserved, which makes MR-guided HIFU promising for the ablation of liver tumors adjacent to large veins. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. The sensitivity of motor response to needle nerve stimulation during ultrasound guided interscalene catheter placement.

    PubMed

    Fredrickson, Michael J

    2008-01-01

    Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.

  14. Ultrasound-guided near-infrared spectroscopy for brain functional study: feasibility analysis and preliminary work

    NASA Astrophysics Data System (ADS)

    Xu, Ronald; Qiang, Bo; Liu, Jun

    2005-04-01

    Recent advances in diffuse optical imaging and spectroscopy (DOIS) allow the noninvasive measurement of local changes in cerebral oxygenation and hemodynamics. Available DOIS devices fall into three categories: time domain (TD), frequency domain (FD) and continuous wave (CW). The TD and FD devices have potential for high spatial resolution, high temporal resolution and high accuracy measurement, but the instrument cost and the hardware size prevent their wide clinical application. Furthermore, the presence of the low scattering cerebrospinal fluid layer (CSF) and its thickness variation during motion challenges quantitative, continuous monitoring of the cortex layer oxygenation and blood content. MRI has been used to provide a priori knowledge of the head anatomy that helps the NIR image reconstruction. However, the technology is expensive and lacks portability. This paper proposes a method that combines the accuracy of a TD/FD system and the portability of a CW device. With the optical baseline measured by a TD or FD device and the layer thickness characterized by an ultrasound transducer, a conventional CW system may be able to quantify the cortex layer optical absorption with high accuracy. In this paper, the feasibility of using ultrasound guided CW spectroscopy to monitor brain activities was studied on a multi layer head model using Monte Carlo simulation and order of magnitude analysis. A forward algorithm based on diffuse approximation and 2D Fourier Transform was used to optimize the source detector separation. Both analytical and neuron network approaches were developed for inverse calculation of the cortex layer absorption in real time. An ultrasound transducer was used to monitor the thickness of different layers surrounding the cerebral cortex. The concept of ultrasound guided CW spectroscopy was demonstrated by numerical simulation on a 2 layer head model and the use of the ultrasound transducer for layer thickness characterization was verified by

  15. Alzheimer disease in a mouse model: MR imaging-guided focused ultrasound targeted to the hippocampus opens the blood-brain barrier and improves pathologic abnormalities and behavior.

    PubMed

    Burgess, Alison; Dubey, Sonam; Yeung, Sharon; Hough, Olivia; Eterman, Naomi; Aubert, Isabelle; Hynynen, Kullervo

    2014-12-01

    To validate whether repeated magnetic resonance (MR) imaging-guided focused ultrasound treatments targeted to the hippocampus, a brain structure relevant for Alzheimer disease ( AD Alzheimer disease ), could modulate pathologic abnormalities, plasticity, and behavior in a mouse model. All animal procedures were approved by the Animal Care Committee and are in accordance with the Canadian Council on Animal Care. Seven-month-old transgenic (TgCRND8) (Tg) mice and their nontransgenic (non-Tg) littermates were entered in the study. Mice were treated weekly with MR imaging-guided focused ultrasound in the bilateral hippocampus (1.68 MHz, 10-msec bursts, 1-Hz burst repetition frequency, 120-second total duration). After 1 month, spatial memory was tested in the Y maze with the novel arm prior to sacrifice and immunohistochemical analysis. The data were compared by using unpaired t tests and analysis of variance with Tukey post hoc analysis. Untreated Tg mice spent 61% less time than untreated non-Tg mice exploring the novel arm of the Y maze because of spatial memory impairments (P < .05). Following MR imaging-guided focused ultrasound, Tg mice spent 99% more time exploring the novel arm, performing as well as their non-Tg littermates. Changes in behavior were correlated with a reduction of the number and size of amyloid plaques in the MR imaging-guided focused ultrasound-treated animals (P < .01). Further, after MR imaging-guided focused ultrasound treatment, there was a 250% increase in the number of newborn neurons in the hippocampus (P < .01). The newborn neurons had longer dendrites and more arborization after MR imaging-guided focused ultrasound, as well (P < .01). Repeated MR imaging-guided focused ultrasound treatments led to spatial memory improvement in a Tg mouse model of AD Alzheimer disease . The behavior changes may be mediated by decreased amyloid pathologic abnormalities and increased neuronal plasticity. © RSNA, 2014.

  16. Simplified stereo-optical ultrasound plane calibration

    NASA Astrophysics Data System (ADS)

    Hoßbach, Martin; Noll, Matthias; Wesarg, Stefan

    2013-03-01

    Image guided therapy is a natural concept and commonly used in medicine. In anesthesia, a common task is the injection of an anesthetic close to a nerve under freehand ultrasound guidance. Several guidance systems exist using electromagnetic tracking of the ultrasound probe as well as the needle, providing the physician with a precise projection of the needle into the ultrasound image. This, however, requires additional expensive devices. We suggest using optical tracking with miniature cameras attached to a 2D ultrasound probe to achieve a higher acceptance among physicians. The purpose of this paper is to present an intuitive method to calibrate freehand ultrasound needle guidance systems employing a rigid stereo camera system. State of the art methods are based on a complex series of error prone coordinate system transformations which makes them susceptible to error accumulation. By reducing the amount of calibration steps to a single calibration procedure we provide a calibration method that is equivalent, yet not prone to error accumulation. It requires a linear calibration object and is validated on three datasets utilizing di erent calibration objects: a 6mm metal bar and a 1:25mm biopsy needle were used for experiments. Compared to existing calibration methods for freehand ultrasound needle guidance systems, we are able to achieve higher accuracy results while additionally reducing the overall calibration complexity. Ke

  17. Renal Sympathetic Denervation by CT-scan-Guided Periarterial Ethanol Injection in Sheep

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Firouznia, Kavous, E-mail: k-firouznia@yahoo.com; Hosseininasab, Sayed jaber, E-mail: dr.hosseininasab@gmail.com; Amanpour, Saeid, E-mail: saeidamanpour@yahoo.com

    BackgroundRenal nerves are a recent target in the treatment of hypertension. Renal sympathetic denervation (RSD) is currently performed using catheter-based radiofrequency ablation (RFA) and because this method has limitations, percutaneous magnetic resonance (MR)-guided periarterial ethanol injection is a suggested alternative. However, few studies have been conducted on the effectiveness of percutaneous ethanol injection for RSD.AimTo evaluate the feasibility, efficacy, and complications of computed tomography (CT)-guided periarterial ethanol injection.MethodsEthanol (10 ml, 99.6 %) was injected around the right renal artery in six sheep under CT guidance with the left kidney serving as a control. Before and after the intervention, the sheep underwent MRmore » imaging studies and the serum creatinine level was measured. One month after the intervention, the sheep were euthanized and norepinephrine (NE) concentration in the renal parenchyma was measured to evaluate the efficacy of the procedure. The treated tissues were also examined histopathologically to evaluate vascular, parenchymal, and neural injury.ResultsThe right kidney parenchymal NE concentration decreased significantly compared with the left kidney after intervention (average reduction: 40 %, P = 0.0016). Histologic examination revealed apparent denervation with no other vascular or parenchymal injuries observed in the histological and imaging studies.ConclusionEffective and feasible RSD was achieved using CT-guided periarterial ethanol injection. This technique may be a potential alternative to catheter-based RFA in the treatment of hypertension.« less

  18. Ultrasound with neurostimulation compared with ultrasound guidance alone for lumbar plexus block: A randomised single blinded equivalence trial.

    PubMed

    Arnuntasupakul, Vanlapa; Chalachewa, Theerawat; Leurcharusmee, Prangmalee; Tiyaprasertkul, Worakamol; Finlayson, Roderick J; Tran, De Q

    2018-03-01

    Ultrasound-guided lumbar plexus blocks usually require confirmatory neurostimulation. A simpler alternative is to inject local anaesthetic inside the posteromedial quadrant of the psoas muscle under ultrasound guidance. We hypothesised that both techniques would result in similar total anaesthesia time, defined as the sum of performance and onset time. A randomised, observer-blinded, equivalence trial. Ramathibodi Hospital and Maharaj Nakorn Chiang Mai Hospital (Thailand) from 12 May 2016 to 10 January 2017. A total of 110 patients undergoing total hip or knee arthroplasty, who required lumbar plexus block for postoperative analgesia. In the combined ultrasonography-neurostimulation group, quadriceps-evoked motor response was sought at a current between 0.2 and 0.8 mA prior to local anaesthetic injection (30 ml of lidocaine 1% and levobupivacaine 0.25% with epinephrine 5 μg ml and 5 mg of dexamethasone). In the ultrasound guidance alone group, local anaesthetic was simply injected inside the posteromedial quadrant of the psoas muscle. We measured the total anaesthesia time, the success rate (at 30 min), the number of needle passes, block-related pain, cumulative opioid consumption (at 24 h) and adverse events (vascular puncture, paraesthesia, local anaesthetic spread to the epidural space). The equivalence margin was 7.4 min. Compared with ultrasound guidance alone, combined ultrasonography-neurostimulation resulted in decreased mean (±SD) total anaesthesia time [15.3 (±6.5) vs. 20.1 (±9.0) min; mean difference, -4.8; 95% confidence interval, -8.1 to -1.9; P = 0.005] and mean (±SD) onset time [10.2 (±5.6) vs. 15.5 (±9.0) min; P = 0.004). No inter-group differences were observed in terms of success rate, performance time, number of needle passes, block-related pain, opioid consumption or adverse events. Although the ultrasonography-neurostimulation technique results in a shorter total anaesthesia time compared with ultrasound

  19. [Efficacy and safety of ultrasound-guided or neurostimulator-guided bilateral axillary brachial plexus block].

    PubMed

    Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G

    2017-10-17

    Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P <0.01). The performance pain score of group N was (25.5± 13.2), which was obviously more serious than group U (31.7± 11.2) and a significant statistical difference was detected ( t =2.856, P <0.05). The patient satisfaction degree of group U was 95.0%, which was significantly higher than group N (83.3%) and a markedly statistical difference was detected (χ(2)=4.227, P <0.05). Fifty min after performance, the total plasma concentration of ropivacaine of group U was(1.76±0.48)mg/L, which was significantly lower than group N (1.88±0.53)mg/L and a significant statistical difference was detected ( t =2.43, P <0.05), while no significant differences were detected at the

  20. A low-cost, durable, combined ultrasound and fluoroscopic phantom for cervical transforaminal injections.

    PubMed

    Lerman, Imanuel R; Souzdalnitski, Dmitri; Narouze, Samer

    2012-01-01

    This technical report describes a durable, low-cost, anatomically accurate, and easy-to-prepare combined ultrasound (US) and fluoroscopic phantom of the cervical spine. This phantom is meant to augment training in US- and fluoroscopic-guided pain medicine procedures. The combined US and fluoroscopic phantom (CUF-P) is prepared from commercially available liquid plastic that is ordinarily used to prepare synthetic fishing lures. The liquid plastic is heated and then poured into a metal canister that houses an anatomical cervical spine model. Drops of dark purple dye are added to make the phantom opaque. After cooling, tubing is attached to the CUF-P to simulate blood vessels. The CUF-P accurately simulates human tissue by imitating both the tactile texture of skin and the haptic resistance of human tissue as the needle is advanced. This phantom contains simulated fluid-filled vertebral arteries that exhibit pulsed flow under color Doppler US. Under fluoroscopic examination, the CUF-P-simulated vertebral arteries also exhibit uptake of contrast dye if mistakenly injected. The creation of a training phantom allows the pain physician to practice needle positioning technique while simultaneously visualizing both targeted and avoidable vascular structures under US and fluoroscopic guidance. This low-cost CUF-P is easy to prepare and is reusable, making it an attractive alternative to current homemade and commercially available phantom simulators.

  1. Effectiveness of Platelet-rich Plasma Injection for Rotator Cuff Tendinopathy: A Prospective Open-label Study.

    PubMed

    Scarpone, Michael; Rabago, David; Snell, Edward; Demeo, Patrick; Ruppert, Kristine; Pritchard, Perry; Arbogast, Gennie; Wilson, John J; Balzano, John F

    2013-03-01

    Assess platelet rich plasma (PRP) injection for rotator cuff tendinopathy (RCT). Prospective open label study with 1-year follow-up. Participants recruited from an outpatient sports medicine clinic had clinically and magnetic resonance image (MRI)-demonstrated RCT refractory to physical therapy and corticosteroid injection. They received one ultrasound-guided injection of 3.0 mL of 1% xylocaine followed by 3.5 mL of PRP at the lesion and surrounding tendon. 0-10 visual analog scale (VAS; baseline, 8, 12, and 52 weeks). functional shoulder tests assessing rotator cuff strength and endurance (at baseline and 8 and 12 weeks), MRI severity (1-5 points [at baseline and 4 and 8 weeks]), and patient satisfaction (52 weeks). Eighteen participants with 19 assessed shoulders reported VAS pain score improvement from 7.5 ± 0.3 points to 0.5 ± 0.3 points by week 12 and 0.4 ± 0.2 (P = .0001) points at week 52. Functional outcomes significantly improved; the largest effect was seen in the external rotation test: 33.5 ± 5.7 seconds to 62.6 ± 7.2 seconds at week 12 (P = .0001). MRI appearance improved by 1 to 3 points in 16 of 18 assessed shoulders. Seventeen participants were "completely satisfied" (12) or "satisfied" (5). One participant was "unsatisfied." A single ultrasound-guided, intralesional injection of PRP resulted in safe, significant, sustained improvement of pain, function, and MRI outcomes in participants with refractory RCT. Randomized multidisciplinary effectiveness trials that add ultrasound and validated clinical outcome measures are needed to further assess PRP for RCT.

  2. Ultrasound-guided plantar fascia release technique: a retrospective study of 46 feet.

    PubMed

    Vohra, Praveen K; Japour, Christopher J

    2009-01-01

    Ultrasound-guided plantar fascia release offers the surgeon clear visualization of anatomy at the surgical site. This technique uses small arthroscopic dissecting instruments through a 0.5-cm incision, allowing the surgeon to avoid the larger and more tissue-disruptive incision that is traditionally used for plantar heel spur resection and plantar fascia releases. Forty-one patients (46 feet) were selected for the study. The mean patient age was 47 years. Twenty-nine were considered obese with a body mass index greater than 30 kg/m(2). Patients were functionally and subjectively evaluated 4 weeks after surgery using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Rating Scale. Results from the study show a significant improvement (P = .05 confidence level) 4 weeks postoperatively for the 41 patients (46 feet), compared to their preoperative condition. The mean pretest score was 33.6 (range 10-52); this score improved to 88.0 (range 50-100), 4 weeks postoperatively. There were no postoperative infections or complications. The ultrasound-guided plantar fascia release technique is a practical surgical procedure for the relief of chronic plantar fascia pain because the surgeon is able to clearly visualize the plantar fascia by ultrasound. In addition, there is minimal disruption to surrounding tissue because small instruments are passed through a small 0.5-cm incision. The traditional open method of heel spur surgery, in contrast, uses a larger skin incision of 3 to 5 cm, followed by larger instruments to dissect to the plantar fascia.

  3. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    ERIC Educational Resources Information Center

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  4. Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation.

    PubMed

    Liu, Tianzhi; Zhang, Nan; Wang, Zhigang; Wu, Meiying; Chen, Yu; Ma, Ming; Chen, Hangrong; Shi, Jianlin

    2017-09-26

    High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H 2 O 2 , facilitating the continuous O 2 gas generation in a relatively mild manner even if incubated with 10 μM H 2 O 2 , which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H 2 O 2 -enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo. Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.

  5. Ultrasound-Guided Forearm Nerve Blocks: A Novel Application for Pain Control in Adult Patients with Digit Injuries

    PubMed Central

    Patricia Javedani, Parisa; Amini, Albert

    2016-01-01

    Phalanx fractures and interphalangeal joint dislocations commonly present to the emergency department. Although these orthopedic injuries are not complex, the four-point digital block used for anesthesia during the reduction can be painful. Additionally, cases requiring prolonged manipulation or consultation for adequate reduction may require repeat blockade. This case series reports four patients presenting after mechanical injuries resulting in phalanx fracture or interphalangeal joint dislocations. These patients received an ultrasound-guided peripheral nerve block of the forearm with successful subsequent reduction. To our knowledge, use of ultrasound-guided peripheral nerve blocks of the forearm for anesthesia in reduction of upper extremity digit injuries in adult patients in the emergency department setting has not been described before. PMID:27555971

  6. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    PubMed Central

    Spugnini, Enrico Pierluigi; Menicagli, Francesco; Pettorali, Michela; Baldi, Alfonso

    2017-01-01

    A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR). Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors. PMID:28331834

  7. [Ultrasound-guided microwave ablation with artificial pleural effusion for liver tumor adjacent to 
diaphragmatic dome].

    PubMed

    Tang, Tian; Gu, Shanzhi; Li, Guowen; Huang, Manping; Huang, Bin; Xiong, Zhengping

    2017-02-28

    To explore the value of ultrasound-guided microwave ablation with artificial pleural effusion for liver tumor adjacent to diaphragmatic dome.
 Methods: A total of 34 patients with liver tumors located at diaphragmatic dome in Hunan Provincial Tumor Hospital were recruited from January 2014 to October 2015. The number of lesions ≤3 or lesion diameter ≤5 cm was in line with the microwave ablation indications. B ultrasound-guided microwave ablation for the liver tumors was undertaken after the artificial pleural effusion being established. 3-4 weeks later after the microwave ablation, all patients were imaged with enhance CT or MRI. The effect of ablation and the complications were evaluated.
 Results: There were 49 lesions in 34 patients, including 30 cases (88.2%) of complete ablation (CA), 3 cases (8.8%) of partial ablation (PA) and one case with new lesions after ablation (2.9%). Thirty-four patients had (1 580±230.7) mL of pleural effusion volume, while one case had bloody pleural effusion. One case had a diaphragmatic thermal injury, and one case had a biliary tumor infection. All of them showed remission after symptomatic treatment. 
 Conclusion: Combination of ultrasound-guided microwave ablation with artificial pleural effusion is a safe and effective therapy for liver tumor adjacent to diaphragmatic dome.

  8. How Much Volume of Local Anesthesia and How Long Should You Wait After Injection for an Effective Wrist Median Nerve Block?

    PubMed

    Lovely, Lyndsay M; Chishti, Yasmin Z; Woodland, Jennifer L; Lalonde, Donald H

    2018-05-01

    Many surgeons and emergentologists use non-ultrasound-guided wrist nerve blocks. There is little evidence to guide the ideal volume of local anesthesia or how long we should wait after injection before performing pain-free procedures. This pilot study examined time to maximal anesthesia to painful needle stick in 14 volunteer participants receiving bilateral wrist blocks of 6 versus 11 mL of local. One surgeon performed all 14 bilateral wrist median nerve blocks in participants who remained blinded until after bandages were applied to their wrist. No one could see which wrist received the larger 11-mL volume injection versus the 6-mL block. Blinded sensory assessors then measured perceived maximal numbness time and numbness to needle stick pain in the fingertips of the median nerve distribution. Failure to get a complete median nerve block occurred in seven of fourteen 6-mL wrist blocks versus failure in only one of fourteen 11-mL blocks. Perceived maximal numbness occurred at roughly 40 minutes after injection, but actual numbness to painful needle stick took around 100 minutes. Incomplete median nerve numbness occurred with both 6- and 11-mL non-ultrasound-guided blocks at the wrist. In those with complete blocks, it took a surprisingly long time of 100 minutes for maximal anesthesia to occur to painful needle stick stimuli to the fingertips of the median nerve distribution. Non-ultrasound-guided median nerve blocks at the wrist as described in this article lack reliability and take too long to work.

  9. Endoscopic Ultrasound-Guided Vascular Therapy: The Present and the Future

    PubMed Central

    Hall, Philip S.J.; Teshima, Christopher; May, Gary R.; Mosko, Jeffrey D.

    2017-01-01

    Endoscopic ultrasound (EUS) offers access to many intra-abdominal vessels that until now have only been accessible to the surgeon and interventional radiologist. In addition to assisting with diagnostics, this unique access offers the potential for therapeutic intervention for a host of indications. To date, this has had the most clinical impact in the treatment of gastroesophageal varices, with EUS-guided coil and glue application growing in use worldwide. Although randomised controlled trial data is lacking, we discuss the growing body of literature behind EUS-guided therapy in the management of varices. EUS has also been used in specialized centres to assist in non-variceal gastrointestinal bleeding. The treatment of bleeding from Dieulafoy lesions, tumours and pancreatic pseudoaneurysms has all been described. The potential applications of EUS have also extended to the placement of portal vein stents and porto-systemic shunts in animal models. As medicine continues to move to increasingly less invasive interventions, EUS-guided therapies offer substantial promise for the safe and effective delivery of targeted treatment for a widening array of vascular disorders. PMID:28391673

  10. Endobronchial ultrasound-guided transbronchial needle aspiration of thyroid: Report of two cases and systematic review of literature

    PubMed Central

    Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep

    2016-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005

  11. WE-H-209-00: Carson/Zagzebski Distinguished Lectureship: Image Guided Ultrasound Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives:more » Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.« less

  12. Real-time three-dimensional ultrasound-assisted axillary plexus block defines soft tissue planes.

    PubMed

    Clendenen, Steven R; Riutort, Kevin; Ladlie, Beth L; Robards, Christopher; Franco, Carlo D; Greengrass, Roy A

    2009-04-01

    Two-dimensional (2D) ultrasound is commonly used for regional block of the axillary brachial plexus. In this technical case report, we described a real-time three-dimensional (3D) ultrasound-guided axillary block. The difference between 2D and 3D ultrasound is similar to the difference between plain radiograph and computer tomography. Unlike 2D ultrasound that captures a planar image, 3D ultrasound technology acquires a 3D volume of information that enables multiple planes of view by manipulating the image without movement of the ultrasound probe. Observation of the brachial plexus in cross-section demonstrated distinct linear hyperechoic tissue structures (loose connective tissue) that initially inhibited the flow of the local anesthesia. After completion of the injection, we were able to visualize the influence of arterial pulsation on the spread of the local anesthesia. Possible advantages of this novel technology over current 2D methods are wider image volume and the capability to manipulate the planes of the image without moving the probe.

  13. Ultrasound-Guided Regional Anesthesia in a Glucose-6-Phosphate Dehydrogenase (G6PD)-Deficient Geriatric Trauma Patient

    PubMed Central

    Födinger, Agnes M.; Kammerlander, Christian; Luger, Thomas J.

    2012-01-01

    Objective: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a genetic enzymatic disorder causing hemolytic anemia. Exposure to drugs is considered to be the most common cause of acute hemolysis in patients with G6PD deficiency. Experience with regional anesthesia, in particular peripheral nerve blocks, is rarely described in patients with G6PD deficiency, but is of great clinical interest. For this reason, we now report on the successful management of ultrasound-guided axillary brachial plexus block in a patient with geriatric G6PD deficiency. Case report: A female, 75-year-old geriatric trauma patient with G6PD deficiency and a fracture of the left forearm, was scheduled for osteosynthesis of the left forearm. For surgery regional anesthesia with ultrasound-guided axillary brachial plexus block with 30 mL bupivacaine 0.5% was established. Surgical operation und postoperative course were uneventful and with no signs of hemolysis. Conclusion: Ultrasound-guided axillary brachial plexus block with bupivacaine was a safe and effective technique in this patient with G6PD deficiency. Peripheral nerve block is a major analgesic approach and of great value for anesthesiologists and surgeons, especially in our aging and multimorbid society. PMID:23569708

  14. Ultrasound-guided direct delivery of 3-bromopyruvate blocks tumor progression in an orthotopic mouse model of human pancreatic cancer.

    PubMed

    Ota, Shinichi; Geschwind, Jean-Francois H; Buijs, Manon; Wijlemans, Joost W; Kwak, Byung Kook; Ganapathy-Kanniappan, Shanmugasundaram

    2013-06-01

    Studies in animal models of cancer have demonstrated that targeting tumor metabolism can be an effective anticancer strategy. Previously, we showed that inhibition of glucose metabolism by the pyruvate analog, 3-bromopyruvate (3-BrPA), induces anticancer effects both in vitro and in vivo. We have also documented that intratumoral delivery of 3-BrPA affects tumor growth in a subcutaneous tumor model of human liver cancer. However, the efficacy of such an approach in a clinically relevant orthotopic tumor model has not been reported. Here, we investigated the feasibility of ultrasound (US) image-guided delivery of 3-BrPA in an orthotopic mouse model of human pancreatic cancer and evaluated its therapeutic efficacy. In vitro, treatment of Panc-1 cells with 3-BrPA resulted in a dose-dependent decrease in cell viability. The loss of viability correlated with a dose-dependent decrease in the intracellular ATP level and lactate production confirming that disruption of energy metabolism underlies these 3-BrPA-mediated effects. In vivo, US-guided delivery of 3-BrPA was feasible and effective as demonstrated by a marked decrease in tumor size on imaging. Further, the antitumor effect was confirmed by (1) a decrease in the proliferative potential by Ki-67 immunohistochemical staining and (2) the induction of apoptosis by terminal deoxynucleotidyl transferase-mediated deoxyuridine 5-triphospate nick end labeling staining. We therefore demonstrate the technical feasibility of US-guided intratumoral injection of 3-BrPA in a mouse model of human pancreatic cancer as well as its therapeutic efficacy. Our data suggest that this new therapeutic approach consisting of a direct intratumoral injection of antiglycolytic agents may represent an exciting opportunity to treat patients with pancreas cancer.

  15. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    PubMed

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  16. Ethnicity influences pain after ultrasound-guided percutaneous liver biopsy.

    PubMed

    Mahadeva, Sanjiv; Mahfudz, Anis S; Vijayananthan, Anushya

    2015-12-01

    The influence of ethnicity on pain complicating ultrasound-guided percutaneous liver biopsy (US-guided PLB) and its clinical impact has not been reported to date. Consecutive adults from a multiethnic background, undergoing an US-guided PLB, were independently assessed for pain up to 6 h after the procedure. Clinical and demographic parameters were analysed to determine independent predictors of significant pain after PLB. Willingness to undergo a repeat procedure was assessed 1 week after PLB. Data from 203 patients (median age 50 years; 43.9% female; ethnicity: Malay 41.5%, Chinese 40%, Indian 18%; median BMI 27.7 kg/m; median waist circumference 92.0 cm) were analysed. Pain after US-guided PLB was experienced in 133 (61.1%) patients, with severity grades as follows: none, n=81 (39.9%); mild, n=56 (27.6%); moderate, n=51 (25.1%); and severe, n=15 (7.4%). Analgesia requirements correlated well with severity of pain. Independent predictors of significant pain after PLB (moderate and severe categories) in patients included age less than 50 years [odds ratio (OR) 3.0], female sex (OR 3.7), Indian ethnicity (OR 2.9) and Malay ethnicity (OR 2.7), but not number of needle passes, BMI and educational levels. Patients who experienced moderate/severe pain were less willing to undergo a repeat PLB compared with those who experienced mild/no pain (60.9 vs. 82.8%, P=0.001). Ethnicity has an important role in the development of pain after US-guided PLB. This has a significant impact on willingness to repeat the procedure.

  17. Ultrasound-Guided Abrams Pleural Biopsy vs CT-Guided Tru-Cut Pleural Biopsy in Malignant Pleural Disease, a 3-Year Follow-up Study.

    PubMed

    Sivakumar, Parthipan; Jayaram, Deepak; Rao, Deepak; Dhileepan, Vignesh; Ahmed, Irfan; Ahmed, Liju

    2016-12-01

    Conventional Abrams biopsy shows low sensitivity in suspected malignant pleural disease. There are limited data on the improvement in sensitivity by adding in image guidance. This retrospective study compares the diagnostic sensitivity of Abrams biopsy using ultrasound guidance with CT-guided Tru-Cut biopsy in suspected malignant pleural disease. Data were collected from 2006 to 2012 of patients who underwent image-guided biopsies for suspected non-tuberculous pleural disease. Data were collected on the result of the initial biopsy and final patient diagnosis as of June 2015. Sixty-three patients underwent image-guided Abrams biopsy and 29 underwent CT-guided Tru-Cut biopsies. The sensitivity of Abrams was 71.43 % compared to 75 % in the CT-guided Tru-Cut group. Specificity was 100 % in both groups. Image-guided Abrams biopsies demonstrate comparable diagnostic sensitivity in malignant pleural disease to CT-guided Tru-Cut biopsy.

  18. Botulinum toxin type A (Botox) for the neuromuscular correction of excessive gingival display on smiling (gummy smile).

    PubMed

    Polo, Mario

    2008-02-01

    Previously, botulinum toxin type A (BTX-A) (Botox; Allergan, Irvine, Calif) was shown to be effective in reducing excessive gingival display in 5 patients with gummy smiles. This study was conducted to determine whether the doses and the primary injection sites used in the pilot study for the correction of gummy smiles provide consistent, statistically significant, and esthetically pleasing results. Thirty patients received BTX-A injections to reduce excessive gingival display. Gingival display was defined as the difference between the lower margin of the upper lip and the superior margin of the right incisor. Patients were followed at 2, 4, 8, 12, 16, 20, and 24 weeks postinjection, with changes documented by photographs and videos. At week 2, the patients rated the effects of BTX-A. A group of specialty clinicians also evaluated the effects of BTX-A. Preinjection gingival display averaged 5.2 +/- 1.4 mm in the 30 patients. At 2 weeks postinjection, mean gingival display had declined to 0.09 mm (+/- 1.06 mm) in 30 patients (t = 26.01, P <.00001). The average lip-drop at 2 weeks was 5.1 mm for 30 patients. Gingival display gradually increased from 2 weeks postinjection through 24 weeks, but, at 24 weeks, average gingival display had not returned to baseline values. Based on predictions from a third-order polynomial equation, the baseline average of 5.2 mm would not be reached until 30 to 32 weeks postinjection. Patients and specialty evaluators rated the effects of BTX-A as highly favorable. BTX-A injections for the neuromuscular correction of gummy smiles caused by hyperfunctional upper lip elevator muscles was effective and statistically superior to baseline smiles, although the effect is transitory.

  19. Ultrasound-guided Interventions for Core and Hip Injuries in Athletes.

    PubMed

    McCarthy, Eoghan; Hegazi, Tarek M; Zoga, Adam C; Morrison, William B; Meyers, William C; Poor, Alex E; Nevalainen, Mika T; Roedl, Johannes B

    2016-09-01

    Trauma and the mechanical strain of high-energy activity predispose athletes to pelvic injuries. Magnetic resonance imaging remains the primary modality for diagnosing these conditions, but ultrasonography-guided interventions are important in the management of core muscle, hip, and other pelvic conditions. This article reviews ultrasonography-guided interventions for injuries at the core, including the pelvis and hips. It reviews common injuries, procedure optimization, medication preparation, clinical evidence behind injections, tenotomy, and platelet-rich plasma. These interventions are especially important in athletes, because ultrasonography-guided procedures are often undertaken early in the treatment process, paralleling conservative rehabilitation to facilitate a faster return to play. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy

    NASA Astrophysics Data System (ADS)

    Hynynen, Kullervo; Jones, Ryan M.

    2016-09-01

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.

  1. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

    PubMed

    Hynynen, Kullervo; Jones, Ryan M

    2016-09-07

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.

  2. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy

    PubMed Central

    Hynynen, Kullervo; Jones, Ryan M.

    2016-01-01

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy. PMID:27494561

  3. [Percutaneous renal puncture guide by a novel real-time needle-tracking ultrasound system for percutaneous nephrolithotomy: analysis of 16 cases].

    PubMed

    Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng

    2014-08-18

    To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.

  4. Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Aliprandi, Alberto; Mauri, Giovanni; Secchi, Francesco; Sardanelli, Francesco; Sconfienza, Luca Maria

    2016-05-01

    Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR imaging, especially when dealing with fibrocartilage and articular cartilage abnormalities. Diluted gadolinium can be injected in the joint space using different approaches: under palpation using anatomic landmarks or using an imaging guidance, such as fluoroscopy, computed tomography, or ultrasound. Fluoroscopy has been traditionally used, but the involvement of ionizing radiation should represent a remarkable limitation of this modality. Conversely, ultrasound has emerged as a feasible, cheap, quick, and radiation-free modality that can be used to inject joints, with comparable accuracy of fluoroscopy. In the present paper, we discuss the advantages and disadvantages of using fluoroscopy or ultrasound in injecting gadolinium-based contrast agents in joints to perform magnetic resonance arthrography, also in view of the new EuroSAFE Imaging initiative promoted by the European Society of Radiology and the recent updates to the European Atomic Energy Community 2013/59 directive on the medical use of ionizing radiation. • Intra-articular contrast agent injection can be performed using different imaging modalities • Fluoroscopy is widely used, but uses ionizing radiation • Ultrasound is an accurate, quick, and radiation-free modality for joint injection • X-rays should be avoided when other radiation-free modalities can be used.

  5. Derivation of a Performance Checklist for Ultrasound-Guided Arthrocentesis Using the Modified Delphi Method.

    PubMed

    Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas

    2017-06-01

    Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.

  6. Ultrasound guided needle localization and microsurgical exploration for incidental nonpalpable testicular tumors.

    PubMed

    Hopps, Carin V; Goldstein, Marc

    2002-09-01

    We describe a technique by which incidental, nonpalpable intratesticular tumors are excised using intraoperative ultrasonography and the operating microscope. Men with impalpable intratesticular tumors incidentally detected by ultrasonography underwent intraoperative ultrasound guided needle localization and microsurgical exploration of the mass. The testis was delivered through an inguinal incision and placed on ice to minimize warm ischemia. Two rubber shod vascular clamps were placed across the spermatic cord. The tumor was identified by ultrasound and localized with a 30 gauge needle, which was placed adjacent to the tumor. An operating microscope providing 6x to 25x magnification was used to excise the lesion with a 2 to 5 mm. margin. Tissue diagnosis was obtained by frozen section. Multiple random biopsies of the remaining parenchyma were done to confirm absent malignancy. Ultrasound showed incidental, nonpalpable testis tumors in 4 of the 65 men who underwent infertility evaluation and were entered into the microsurgical testis biopsy database between January 1995 and December 2001. All lesions were hypoechoic. Frozen section analysis of the lesions revealed 2 Leydig cell tumors, 1 mass with an inconclusive pathological diagnosis and 1 inflammatory mass. On permanent section the latter 2 lesions were seminoma. The seminomas were 1.6 and 0.9 cm. in the greatest diameter, and the Leydig cell tumors were 0.35 and 0.2 cm., respectively. Random biopsies were positive for seminoma and intratubular germ cell neoplasia in both testes with seminoma. These 2 patients subsequently opted to undergo radical orchiectomy. No residual tumor was detected in either radical orchiectomy specimen. Intraoperative ultrasound guided needle localization with microsurgical exploration is a safe and effective approach to even small impalpable testicular masses. This technique provides the opportunity to identify and remove benign and malignant lesions, and preserve the testis when the

  7. Ultrasound guided transrectal catheter drainage of pelvic collections.

    PubMed

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  8. Ultrasound-guided hydrostatic reduction of intussusception with saline: Safe and effective.

    PubMed

    Karadağ, Çetin Ali; Abbasoğlu, Latif; Sever, Nihat; Kalyoncu, Meltem Kaba; Yıldız, Abdullah; Akın, Melih; Candan, Mustafa; Dokucu, Ali İhsan

    2015-09-01

    The study was undertaken to assess the efficacy of ultrasound-guided saline enema in reducing intussusception and to determine the role of age and duration of symptoms on this event. The case records of patients who were treated for intussusception at our institutions over the past 10 years were retrospectively analyzed. A total of 419 patients were treated for intussusception and 375 of them were included into the study. Patients were excluded if they had symptoms and signs of acute abdominal disease and required surgery as an initial treatment. Hydrostatic reduction was successful in 313 of the 375 patients (83.46%). The procedure-related complication rate was nil. There were 29 episodes of recurrences in 23 patients, and recurrence rates did not differ between patients who responded to hydrostatic reduction and those who required surgery. Younger age [median (range); 11 months (3-108 months) vs. 20 months (1-180 months); p<0.05], rectal bleeding (p<0.01) and long duration of symptoms [mean (range); 1.95 days (1-7 days) vs. 1.44 days (1-10 days); p<0.01] were significantly associated with failed hydrostatic reduction. Ultrasound-guided hydrostatic reduction is an easy, safe and effective method for the treatment of intussusception in the absence of acute abdominal findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. State of education regarding ultrasound-guided interventions during pain fellowships in Korea: a survey of recent fellows

    PubMed Central

    Kim, Hyung Tae; Kim, Sae Young; Byun, Gyung Jo; Shin, Byung Chul; Lee, Jin Young; Choi, Eun Joo; Choi, Jong Bum; Hong, Ji Hee; Choi, Seung Won

    2017-01-01

    Background Recently, the use of ultrasound (US) techniques in regional anesthesia and pain medicine has increased significantly. However, the current extent of training in the use of US-guided pain management procedures in Korea remains unknown. The purpose of the present study was to assess the current state of US training provided during Korean Pain Society (KPS) pain fellowship programs through the comparative analysis between training hospitals. Methods We conducted an anonymous survey of 51 pain physicians who had completed KPS fellowships in 2017. Items pertained to current US practices and education, as well as the types of techniques and amount of experience with US-guided pain management procedures. Responses were compared based on the tier of the training hospital. Results Among the 51 respondents, 14 received training at first- and second-tier hospitals (Group A), while 37 received training at third-tier hospitals (Group B). The mean total duration of pain training during the 1-year fellowship was 7.4 months in Group A and 8.4 months in Group B. Our analysis revealed that 36% and 40% of respondents in Groups A and B received dedicated US training, respectively. Most respondents underwent US training in patient-care settings under the supervision of attending physicians. Cervical root, stellate ganglion, piriformis, and lumbar plexus blocks were more commonly performed by Group B than by Group A (P < 0.05). Conclusions Instruction regarding US-guided pain management interventions varied among fellowship training hospitals, highlighting the need for the development of educational standards that mandate a minimum number of US-guided nerve blocks or injections during fellowships in interventional pain management. PMID:29123624

  10. High resolution ultrasound-guided microinjection for interventional studies of early embryonic and placental development in vivo in mice

    PubMed Central

    Slevin, John C; Byers, Lois; Gertsenstein, Marina; Qu, Dawei; Mu, Junwu; Sunn, Nana; Kingdom, John CP; Rossant, Janet; Adamson, S Lee

    2006-01-01

    Background In utero microinjection has proven valuable for exploring the developmental consequences of altering gene expression, and for studying cell lineage or migration during the latter half of embryonic mouse development (from embryonic day 9.5 of gestation (E9.5)). In the current study, we use ultrasound guidance to accurately target microinjections in the conceptus at E6.5–E7.5, which is prior to cardiovascular or placental dependence. This method may be useful for determining the developmental effects of targeted genetic or cellular interventions at critical stages of placentation, gastrulation, axis formation, and neural tube closure. Results In 40 MHz ultrasound images at E6.5, the ectoplacental cone region and proamniotic cavity could be visualized. The ectoplacental cone region was successfully targeted with 13.8 nL of a fluorescent bead suspension with few or no beads off-target in 51% of concepti microinjected at E6.5 (28/55 injected). Seventy eight percent of the embryos survived 2 to 12 days post injection (93/119), 73% (41/56) survived to term of which 68% (38/56) survived and appeared normal one week after birth. At E7.5, the amniotic and exocoelomic cavities, and ectoplacental cone region were discernable. Our success at targeting with few or no beads off-target was 90% (36/40) for the ectoplacental cone region and 81% (35/43) for the exocoelomic cavity but tended to be less, 68% (34/50), for the smaller amniotic cavity. At E11.5, beads microinjected at E7.5 into the ectoplacental cone region were found in the placental spongiotrophoblast layer, those injected into the exocoelomic cavity were found on the surface or within the placental labyrinth, and those injected into the amniotic cavity were found on the surface or within the embryo. Following microinjection at E7.5, survival one week after birth was 60% (26/43) when the amniotic cavity was the target and 66% (19/29) when the target was the ectoplacental cone region. The survival rate was

  11. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  12. Endobronchial ultrasound-guided transbronchial needle aspiration of pulmonary artery tumors: A systematic review (with video).

    PubMed

    Harris, Kassem; Modi, Kush; Kumar, Abhishek; Dhillon, Samjot Singh

    2015-01-01

    Convex probe endobronchial ultrasound (CP-EBUS) was originally introduced as a diagnostic and staging tool for lung cancer and subsequently utilized for diagnosis of other malignant and benign mediastinal diseases such as melanoma, lymphoma, and sarcoidosis. More recently, CP-EBUS has been successfully used for the visualization and diagnosis of pulmonary emboli and other vascular lesions including primary and metastatic pulmonary artery (PA) tumors. In this review, we will underline the role of EBUS-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of pulmonary arterial tumors such as sarcomas and tumor emboli. We will concisely discuss the clinical applications of EBUS-TBNA and the types of pulmonary arterial tumors and their different diagnostic modalities. We searched the Cochrane Library and PubMed from 2004 to 2014 to provide the most comprehensive review. Only 10 cases of EBUS-TBNA for intravascular lesions were identified in the literature. Although many cases of EBUS and EUS-guided transvascular tumor biopsies were described in the literature, there were no reported cases of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for intravascular tumor biopsies. Except for one paper, all cases were published as case reports.

  13. Fluoroscopically Guided Peritendinous Corticosteroid Injection for Proximal Hamstring Tendinopathy: A Retrospective Review.

    PubMed

    Nicholson, Luke T; DiSegna, Steven; Newman, Joel S; Miller, Suzanne L

    2014-03-01

    Proximal hamstring tendinopathy is an uncommon but debilitating cause of posterior thigh pain in athletes subjected to repetitive eccentric hamstring contraction, such as runners. Minimal data exist evaluating treatment options for proximal hamstring tendinopathy. This retrospective study evaluates the effectiveness of fluoroscopically guided corticosteroid injections in treating proximal hamstring tendinopathy. Case series; Level of evidence, 4. Eighteen athletes with 22 cases of magnetic resonance imaging-confirmed proximal hamstring tendinopathy were treated with corticosteroid injection and later contacted to evaluate the efficacy of the injection with the use of a questionnaire. The visual analog score decreased from 7.22 preinjection to 3.94 postinjection (P < .001), level of athletic participation increased from 28.76% to 68.82% (P < .001) at a mean follow-up of 21 months, and 38.8% of patients experienced complete resolution at a mean follow-up of 24.8 months. The mean lower extremity function score at the time of follow-up was 60. A trial of fluoroscopically guided corticosteroid injection is warranted in patients presenting with symptoms of proximal hamstring tendinopathy refractory to conservative therapy.

  14. Prostate tissue ablation with MRI guided transurethral therapeutic ultrasound and intraoperative assessment of the integrity of the neurovascular bundle

    NASA Astrophysics Data System (ADS)

    Sammet, Steffen; Partanen, Ari; Yousuf, Ambereen; Wardrip, Craig; Niekrasz, Marek; Antic, Tatjana; Razmaria, Aria; Sokka, Sham; Karczmar, Gregory; Oto, Aytekin

    2017-03-01

    OBJECTIVES: Evaluation of the precision of prostate tissue ablation with MRI guided therapeuticultrasound by intraoperative objective assessment of the neurovascular bundle in canines in-vivo. METHODS: In this ongoing IACUC approved study, eight male canines were scanned in a clinical 3T Achieva MRI scanner (Philips) before, during, and after ultrasound therapy with a prototype MR-guided ultrasound therapy system (Philips). The system includes a therapy console to plan treatment, to calculate real-time temperature maps, and to control ultrasound exposures with temperature feedback. Atransurethral ultrasound applicator with eight transducer elements was used to ablate canine prostate tissue in-vivo. Ablated prostate tissue volumes were compared to the prescribed target volumes to evaluate technical effectiveness. The ablated volumes determined by MRI (T1, T2, diffusion, dynamic contrast enhanced and 240 CEM43 thermal dose maps) were compared to H&E stained histological slides afterprostatectomy. Potential nerve damage of the neurovascular bundle was objectively assessed intraoperativelyduring prostatectomy with a CaverMap Surgical Aid nerve stimulator (Blue Torch Medical Technologies). RESULTS: Transurethral MRI -guided ultrasound therapy can effectively ablate canine prostate tissue invivo. Coronal MR-imaging confirmed the correct placement of the HIFU transducer. MRI temperature maps were acquired during HIFU treatment, and subsequently used for calculating thermal dose. Prescribed target volumes corresponded to the 240 CEM43 thermal dose maps during HIFU treatment in all canines. Ablated volumes on high resolution anatomical, diffusion weighted, and contrast enhanced MR images matched corresponding histological slides after prostatectomy. MRI guidance with realtime temperature monitoring showed no damage to surrounding tissues, especially to the neurovascular bundle (assessed intra-operatively with a nerve stimulator) or to the rectum wall. CONCLUSIONS: Our study

  15. Evaluation of ultrasound-guided vascular access in dogs.

    PubMed

    Chamberlin, Scott C; Sullivan, Lauren A; Morley, Paul S; Boscan, Pedro

    2013-01-01

    To describe the technique and determine the feasibility, success rate, perceived difficulty, and time to vascular access using ultrasound guidance for jugular vein catheterization in a cardiac arrest dog model. Prospective descriptive study. University teaching hospital. Nine Walker hounds. A total of 27 jugular catheterizations were performed postcardiac arrest using ultrasound guidance. Catheterizations were recorded based on the order in which they were performed and presence/absence of a hematoma around the vein. Time (minutes) until successful vascular access and perceived difficulty in achieving vascular access (scale of 1 = easy to 10 = difficult) were recorded for each catheterization. Mean time to vascular access was 1.9 minutes (95% confidence interval, 1.1-3.4 min) for catheterizations without hematoma, versus 4.3 minutes (1.8-10.1 min) for catheterizations with hematoma (P = 0.1). Median perceived difficulty was 2 of 10 (range 1-7) for catheterizations without hematoma, versus 2 of 10 (range 1-8) for catheterizations with hematoma (P = 0.3). A learning curve was evaluated by comparing mean time to vascular access and perceived difficulty in initial versus subsequent catheterizations. Mean time to vascular access was 2.5 minutes (1.0-6.4 min) in the initial 13 catheterizations versus 3.3 minutes (1.5-7.5 min) in the subsequent 14 catheterizations (P = 0.6). Median perceived difficulty in the first 13 catheterizations (3, range 1-8) was significantly greater (P = 0.049) than median perceived difficulty in the subsequent 14 catheterizations (2, range 1-6). Ultrasound-guided jugular catheterization is associated with a learning curve but is successful in obtaining rapid vascular access in dogs. Further prospective studies are warranted to confirm the utility of this technique in a clinical setting. © Veterinary Emergency and Critical Care Society 2013.

  16. Technical communication: new teaching model for practicing ultrasound-guided regional anesthesia techniques: no perishable food products!

    PubMed

    Liu, Yang; Glass, Nancy L; Power, Robert W

    2010-04-01

    There is a pronounced learning curve for the technique of ultrasound-guided regional anesthesia. Practicing with a simulator model has been shown to speed the acquisition of these skills for various ultrasound-guided procedures. However, commercial models for ultrasound-guided regional anesthesia may be too costly or not readily available. Models using turkey breasts or tofu blocks have the disadvantage of containing perishable food products that can be a source for infection. We describe an alternative inexpensive model that is made from nonperishable components readily available in the operating room. The materials required include 1 clean used 500-mL bag of IV fluids, a bottle of Premisorb (TYCO Healthcare Group, Mansfield, MA), and a piece of foam material approximately 0.3 cm in diameter and 5 cm in length trimmed from operating room foam pads. After filling the IV bag with tap water and inserting the foam into the IV bag from the outlet port of the IV bag, one-third of a bottle of Premisorb (approximately 15 g) is poured into the IV bag. The outlet port of the bag is then sealed by taping the rubber stopper that originally came with the bag. Premisorb, a solidifying agent frequently used to absorb irrigating fluids or blood in operating room suction canisters, produces a gel-like material in the IV bag. The foam inserted into the bag creates a relatively hyperechoic target. This gel-like substance in the bag will seal the holes created after multiple practice needle insertions, resulting in minimal leakage. The semitransparent nature of the gel allows the trainee to visualize the target directly and on the ultrasound screen. The model we describe is inexpensive and easy to make from materials readily available in the operating room with the advantages of being nonperishable, easy to carry, and reusable.

  17. An inexpensive, easily constructed, reusable task trainer for simulating ultrasound-guided pericardiocentesis.

    PubMed

    Zerth, Herb; Harwood, Robert; Tommaso, Laura; Girzadas, Daniel V

    2012-12-01

    Pericardiocentesis is a low-frequency, high-risk procedure integral to the practice of emergency medicine. Ultrasound-guided pericardiocentesis is the preferred technique for providing this critical intervention. Traditionally, emergency physicians learned pericardiocentesis in real time, at the bedside, on critically ill patients. Medical education is moving toward simulation for training and assessment of procedures such as pericardiocentesis because it allows learners to practice time-sensitive skills without risk to patient or learner. The retail market for models for pericardiocentesis practice is limited and expensive. We have developed an ultrasound-guided pericardiocentesis task trainer that allows the physician to insert a needle under ultrasound guidance, pierce the "pericardial sac" and aspirate "blood." Our model can be simply constructed in a home kitchen, and the overall preparation time is 1 h. Our model costs $20.00 (US, 2008). Materials needed for the construction include 16 ounces of plain gelatin, one large balloon, one golf ball, food coloring, non-stick cooking spray, one wooden cooking skewer, surgical iodine solution, and a 4-quart sized plastic food storage container. Refrigeration and a heat source for cooking are also required. Once prepared, the model is usable for 2 weeks at room temperature and may be preserved an additional week if refrigerated. When the model shows signs of wear, it can be easily remade, by simply recycling the existing materials. The self-made model was well liked by training staff due to accessibility of a simulation model, and by learners of the technique as they felt more at ease performing pericardiocentesis on a live patient. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Doppler ultrasound-guided percutaneous nephrolithotomy with two-step tract dilation for management of complex renal stones.

    PubMed

    Xu, Youming; Wu, Zhonghua; Yu, Jianhua; Wang, Shulong; Li, Fang; Chen, Jiushun; Liu, Jin; Chen, Kan

    2012-06-01

    To report our experience and assess the safety and efficacy of Doppler ultrasound-guided percutaneous nephrolithotomy (PCNL) with 2-step tract dilation for complex renal stones. From March 2009 to February 2011, 262 patients underwent PCNL. Eighty-three patients had a complete and 105 had partial staghorn calculus, and 74 had a renal pelvic stone of >2 cm in diameter. Thirty-five patients had renal surgical history. Doppler ultrasound-guided PCNL with 2-step tract dilation were performed. Stones were fragmented and cleared using a combination of ultrasonic and pneumatic lithotripters. All PCNL procedures were successful. Successful access to the collecting system was 100%. Although most of the cases (231/262) were managed satisfactorily by a single tract, a second tract was used in 31 cases. Mean operation time was 56 minutes (range 25-145). The primary stone-free rate of PCNL was 80.9%. There were 39 auxiliary procedures (13 second PCNL and 26 extracorporeal shock wave lithotripsy). One month after treatment, the overall stone-free rate was 92.7%. Five patients (1.9%) received blood transfusion. Eight patients (3.1%) with a postoperative fever of ≥38.5°C were cured by intravenous antibiotics. No other severe complications occurred. The mean postoperative stay was 3.8 days (range 2-12). Doppler ultrasound-guided PCNL with 2-step tract dilation for complex renal stones is safe, effective, and worthy of wider use in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrover, David, E-mail: dpetrover@yahoo.fr; Silvera, Jonathan, E-mail: silvera.jonathan@gmail.com; Baere, Thierry De, E-mail: Debaere@igr.fr

    ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 atmore » baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.« less

  20. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles

    NASA Astrophysics Data System (ADS)

    Burgess, M. T.; Apostolakis, I.; Konofagou, E. E.

    2018-03-01

    Image-guided monitoring of microbubble-based focused ultrasound (FUS) therapies relies on the accurate localization of FUS-stimulated microbubble activity (i.e. acoustic cavitation). Passive cavitation imaging with ultrasound arrays can achieve this, but with insufficient spatial resolution. In this study, we address this limitation and perform high-resolution monitoring of acoustic cavitation-mediated blood-brain barrier (BBB) opening with a new technique called power cavitation imaging. By synchronizing the FUS transmit and passive receive acquisition, high-resolution passive cavitation imaging was achieved by using delay and sum beamforming with absolute time delays. Since the axial image resolution is now dependent on the duration of the received acoustic cavitation emission, short pulses of FUS were used to limit its duration. Image sets were acquired at high-frame rates for calculation of power cavitation images analogous to power Doppler imaging. Power cavitation imaging displays the mean intensity of acoustic cavitation over time and was correlated with areas of acoustic cavitation-induced BBB opening. Power cavitation-guided BBB opening with FUS could constitute a standalone system that may not require MRI guidance during the procedure. The same technique can be used for other acoustic cavitation-based FUS therapies, for both safety and guidance.

  1. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles.

    PubMed

    Burgess, M T; Apostolakis, I; Konofagou, E E

    2018-03-15

    Image-guided monitoring of microbubble-based focused ultrasound (FUS) therapies relies on the accurate localization of FUS-stimulated microbubble activity (i.e. acoustic cavitation). Passive cavitation imaging with ultrasound arrays can achieve this, but with insufficient spatial resolution. In this study, we address this limitation and perform high-resolution monitoring of acoustic cavitation-mediated blood-brain barrier (BBB) opening with a new technique called power cavitation imaging. By synchronizing the FUS transmit and passive receive acquisition, high-resolution passive cavitation imaging was achieved by using delay and sum beamforming with absolute time delays. Since the axial image resolution is now dependent on the duration of the received acoustic cavitation emission, short pulses of FUS were used to limit its duration. Image sets were acquired at high-frame rates for calculation of power cavitation images analogous to power Doppler imaging. Power cavitation imaging displays the mean intensity of acoustic cavitation over time and was correlated with areas of acoustic cavitation-induced BBB opening. Power cavitation-guided BBB opening with FUS could constitute a standalone system that may not require MRI guidance during the procedure. The same technique can be used for other acoustic cavitation-based FUS therapies, for both safety and guidance.

  2. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    PubMed

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological

  3. Survey of ultrasound practice amongst podiatrists in the UK.

    PubMed

    Siddle, Heidi J; Patience, Aimie; Coughtrey, James; Mooney, Jean; Fox, Martin; Cherry, Lindsey

    2018-01-01

    Ultrasound in podiatry practice encompasses musculoskeletal ultrasound imaging, vascular hand-held Doppler ultrasound and therapeutic ultrasound. Sonography practice is not regulated by the Health and Care Professions Council (HCPC), with no requirement to hold a formal qualification. The College of Podiatry does not currently define ultrasound training and competencies.This study aimed to determine the current use of ultrasound, training received and mentorship received and/or provided by podiatrists using ultrasound. A quantitative study utilising a cross-sectional, on-line, single-event survey was undertaken within the UK. Completed surveys were received from 284 podiatrists; 173 (70%) use ultrasound as part of their general practice, 139 (49%) for musculoskeletal problems, 131 (46%) for vascular assessment and 39 (14%) to support their surgical practice. Almost a quarter ( n  = 62) worked for more than one organisation; 202 (71%) were employed by the NHS and/or private sector ( n  = 118, 41%).Nearly all (93%) respondents report using a hand-held vascular Doppler in their daily practice; 216 (82%) to support decisions regarding treatment options, 102 (39%) to provide diagnostic reports for other health professionals, and 34 (13%) to guide nerve blocks.Ultrasound imaging was used by 104 (37%) respondents primarily to aid clinical decision making ( n  = 81) and guide interventions (steroid injections n  = 67; nerve blocks n  = 39). Ninety-three percent stated they use ultrasound imaging to treat their own patients, while others scan at the request of other podiatrists ( n  = 28) or health professionals ( n  = 18). Few use ultrasound imaging for research ( n  = 7) or education ( n  = 2).Only 32 (11%) respondents ( n  = 20 private sector) use therapeutic ultrasound to treat patients presenting with musculoskeletal complaints, namely tendon pathologies.Few respondents (18%) had completed formal post-graduate CASE (Consortium

  4. Ultrasound in Radiology: from Anatomic, Functional, Molecular Imaging to Drug Delivery and Image-Guided Therapy

    PubMed Central

    Klibanov, Alexander L.; Hossack, John A.

    2015-01-01

    During the past decade, ultrasound has expanded medical imaging well beyond the “traditional” radiology setting - a combination of portability, low cost and ease of use makes ultrasound imaging an indispensable tool for radiologists as well as for other medical professionals who need to obtain imaging diagnosis or guide a therapeutic intervention quickly and efficiently. Ultrasound combines excellent ability for deep penetration into soft tissues with very good spatial resolution, with only a few exceptions (i.e. those involving overlying bone or gas). Real-time imaging (up to hundreds and thousands frames per second) enables guidance of therapeutic procedures and biopsies; characterization of the mechanical properties of the tissues greatly aids with the accuracy of the procedures. The ability of ultrasound to deposit energy locally brings about the potential for localized intervention encompassing: tissue ablation, enhancing penetration through the natural barriers to drug delivery in the body and triggering drug release from carrier micro- and nanoparticles. The use of microbubble contrast agents brings the ability to monitor and quantify tissue perfusion, and microbubble targeting with ligand-decorated microbubbles brings the ability to obtain molecular biomarker information, i.e., ultrasound molecular imaging. Overall, ultrasound has become the most widely used imaging modality in modern medicine; it will continue to grow and expand. PMID:26200224

  5. MRI-Guided Focused Ultrasound as a New Method of Drug Delivery

    PubMed Central

    Thanou, M.; Gedroyc, W.

    2013-01-01

    Ultrasound-mediated drug delivery under the guidance of an imaging modality can improve drug disposition and achieve site-specific drug delivery. The term focal drug delivery has been introduced to describe the focal targeting of drugs in tissues with the help of imaging and focused ultrasound. Focal drug delivery aims to improve the therapeutic profile of drugs by improving their specificity and their permeation in defined areas. Focused-ultrasound- (FUS-) mediated drug delivery has been applied with various molecules to improve their local distribution in tissues. FUS is applied with the aid of microbubbles to enhance the permeability of bioactive molecules across BBB and improve drug distribution in the brain. Recently, FUS has been utilised in combination with MRI-labelled liposomes that respond to temperature increase. This strategy aims to “activate” nanoparticles to release their cargo locally when triggered by hyperthermia induced by FUS. MRI-guided FUS drug delivery provides the opportunity to improve drug bioavailability locally and therefore improve the therapeutic profiles of drugs. This drug delivery strategy can be directly translated to clinic as MRg FUS is a promising clinically therapeutic approach. However, more basic research is required to understand the physiological mechanism of FUS-enhanced drug delivery. PMID:23738076

  6. Focused Ultrasound Surgery for Uterine Fibroids

    MedlinePlus

    ... ultrasound surgery, your doctor may perform a pelvic magnetic resonance imaging (MRI) scan before treatment. Focused ultrasound surgery — also called magnetic resonance-guided focused ultrasound surgery or focused ultrasound ...

  7. Randomized comparison of three transducer orientation approaches for ultrasound guided internal jugular venous cannulation.

    PubMed

    Batllori, M; Urra, M; Uriarte, E; Romero, C; Pueyo, J; López-Olaondo, L; Cambra, K; Ibáñez, B

    2016-03-01

    Ultrasound-guided internal jugular venous access increases the rate of successful cannulation and reduces the incidence of complications, compared with the landmark technique. Three transducer orientation approaches have been proposed for this procedure: short-axis (SAX), long-axis (LAX) and oblique-axis (OAX). Our goal was to assess and compare the performance of these approaches. A prospective randomized clinical trial was conducted in one teaching hospital. Patients aged 18 yr or above, who were undergoing ultrasound-guided internal jugular cannulation, were randomly assigned to one of three intervention groups: SAX, LAX and OAX group. The main outcome measure was successful cannulation on first needle pass. Incidence of mechanical complications was also registered. Restricted randomization was computer-generated. In total, 220 patients were analysed (SAX n=73, LAX n=75, OAX n=72). Cannulation was successful on first needle pass in 51 (69.9%) SAX patients, 39 (52%) LAX patients and 53 (73.6%) OAX patients. First needle pass failure was higher in the LAX group than in the OAX group (adjusted OR 3.7, 95% CI 1.71-8.0, P=0.002). A higher mechanical complication rate was observed in the SAX group (15.1%) than in the OAX (6.9%) and LAX (4%) groups (P=0.047). As OAX showed a higher first needle pass success rate than LAX and a lower mechanical complications rate than SAX, we recommend it as the standard approach when performing ultrasound-guided internal jugular venous access. Further clinical studies are needed to confirm this conclusion. NCT 01966354. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Speech Intelligibility in Severe Adductor Spasmodic Dysphonia

    ERIC Educational Resources Information Center

    Bender, Brenda K.; Cannito, Michael P.; Murry, Thomas; Woodson, Gayle E.

    2004-01-01

    This study compared speech intelligibility in nondisabled speakers and speakers with adductor spasmodic dysphonia (ADSD) before and after botulinum toxin (Botox) injection. Standard speech samples were obtained from 10 speakers diagnosed with severe ADSD prior to and 1 month following Botox injection, as well as from 10 age- and gender-matched…

  9. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. High-frequency ultrasound-guided disruption of glycoprotein VI-targeted microbubbles targets atheroprogressison in mice.

    PubMed

    Metzger, Katja; Vogel, Sebastian; Chatterjee, Madhumita; Borst, Oliver; Seizer, Peter; Schönberger, Tanja; Geisler, Tobias; Lang, Florian; Langer, Harald; Rheinlaender, Johannes; Schäffer, Tilman E; Gawaz, Meinrad

    2015-01-01

    Targeted contrast-enhanced ultrasound (CEU) using microbubble agents is a promising non-invasive imaging technique to evaluate atherosclerotic lesions. In this study, we decipher the diagnostic and therapeutic potential of targeted-CEU with soluble glycoprotein (GP)-VI in vivo. Microbubbles were conjugated with the recombinant fusion protein GPVI-Fc (MBGPVI) that binds with high affinity to atherosclerotic lesions. MBGPVI or control microbubbles (MBC) were intravenously administered into ApoE(-/-) or wild type mice and binding of the microbubbles to the vessel wall was visualized by high-resolution CEU. CEU molecular imaging signals of MBGPVI were substantially enhanced in the aortic arch and in the truncus brachiocephalicus in ApoE(-/-) as compared to wild type mice. High-frequency ultrasound (HFU)-guided disruption of MBGPVI enhanced accumulation of GPVI in the atherosclerotic lesions, which may interfere with atheroprogression. Thus, we establish targeted-CEU with soluble GPVI as a novel non-invasive molecular imaging method for atherosclerosis. Further, HFU-guided disruption of GPVI-targeted microbubbles is an innovate therapeutic approach that potentially prevents progression of atherosclerotic disease. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. MR-Guided Pulsed High-Intensity Focused Ultrasound Enhancement of Gene Therapy Combined With Androgen Deprivation and Radiotherapy for Prostate Cancer Treatment

    DTIC Science & Technology

    2009-09-01

    first statement of work is to determine if high intensity focused ultrasound ( HIFU ) increases the cellular uptake of AS-MDM2, AS-bcl-2 and AS-PKA...Drug Delivery in Prostate Tumor in vivo Using MR Guided Focused Ultrasound (MRg HIFU ). WC, IFMBE Proceedings 25: pp341-344, 2009 6...pharmaceutical agents in the treatment target. In the model system proposed, pulsed high intensity focused ultrasound ( HIFU ) is hypothesized to improve

  12. A motorized ultrasound system for MRI-ultrasound fusion guided prostatectomy

    NASA Astrophysics Data System (ADS)

    Seifabadi, Reza; Xu, Sheng; Pinto, Peter; Wood, Bradford J.

    2016-03-01

    Purpose: This study presents MoTRUS, a motorized transrectal ultrasound system, to enable remote navigation of a transrectal ultrasound (TRUS) probe during da Vinci assisted prostatectomy. MoTRUS not only provides a stable platform to the ultrasound probe, but also allows the physician to navigate it remotely while sitting on the da Vinci console. This study also presents phantom feasibility study with the goal being intraoperative MRI-US image fusion capability to bring preoperative MR images to the operating room for the best visualization of the gland, boundaries, nerves, etc. Method: A two degree-of-freedom probe holder is developed to insert and rotate a bi-plane transrectal ultrasound transducer. A custom joystick is made to enable remote navigation of MoTRUS. Safety features have been considered to avoid inadvertent risks (if any) to the patient. Custom design software has been developed to fuse pre-operative MR images to intraoperative ultrasound images acquired by MoTRUS. Results: Remote TRUS probe navigation was evaluated on a patient after taking required consents during prostatectomy using MoTRUS. It took 10 min to setup the system in OR. MoTRUS provided similar capability in addition to remote navigation and stable imaging. No complications were observed. Image fusion was evaluated on a commercial prostate phantom. Electromagnetic tracking was used for the fusion. Conclusions: Motorized navigation of the TRUS probe during prostatectomy is safe and feasible. Remote navigation provides physician with a more precise and easier control of the ultrasound image while removing the burden of manual manipulation of the probe. Image fusion improved visualization of the prostate and boundaries in a phantom study.

  13. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  14. Acoustic characterization of Thiel liver for magnetic resonance-guided focused ultrasound treatment.

    PubMed

    Karakitsios, Ioannis; Joy, Joyce; Mihcin, Senay; Melzer, Andreas

    2017-04-01

    The purpose of this work was to measure the essential acoustic parameters, i.e., acoustic impedance, reflection coefficient, attenuation coefficient, of Thiel embalmed human and animal liver. The Thiel embalmed tissue can be a promising, pre-clinical model to study liver treatment with Magnetic Resonance-guided Focused Ultrasound (MRgFUS). Using a single-element transducer and the contact pulse-echo method, the acoustic parameters, i.e., acoustic impedance, reflection coefficient and attenuation coefficient of Thiel embalmed human and animal liver were measured. The Thiel embalmed livers had higher impedance, similar reflection and lower attenuation compared to the fresh tissue. Embalming liver with Thiel fluid affects its acoustic properties. During MRgFUS sonication of a Thiel organ, more focused ultrasound (FUS) will be backscattered by the organ, and higher acoustic powers are required to reach coagulation levels (temperatures >56 °C).

  15. Perioperative ultrasound-guided wire marking of calcific deposits in calcifying tendinitis of the rotator cuff.

    PubMed

    Sigg, Andreas; Draws, Detlev; Stamm, Axel; Pfeiffer, Michael

    2011-03-01

    The identification of a calcific deposit in the rotator cuff can often cause difficulties. A new technique is described to identify the calcific deposit perioperatively with a ultrasound-guided wire. The technique allows a safe direct marking of calcific deposits making the procedure faster especially in difficult cases.

  16. A randomised crossover study to compare the cross-sectional and longitudinal approaches to ultrasound-guided peripheral venepuncture in a model.

    PubMed

    Griffiths, James; Carnegie, Amadeus; Kendall, Richard; Madan, Rajeev

    2017-12-01

    Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we investigated whether novice ultrasound users should adopt a cross-sectional or longitudinal approach when learning to access peripheral veins under ultrasound guidance. This result would inform the development of a structured training method for this procedure. We conducted a randomised controlled trial of 30 medical students. Subjects received 35 min of training, then attempted to aspirate 1 ml of synthetic blood from a deep vein in a training model under ultrasound guidance. Subjects attempted both the cross-sectional and longitudinal approaches. Group 1 used cross-sectional first, followed by longitudinal. Group 2 used longitudinal first, then cross-sectional. We measured the time from first puncture of the model's skin to aspiration of fluid, and the number of attempts required. Subjects also reported difficulty ratings for each approach. Paired sample t-tests were used for statistical analysis. The mean number of attempts was 1.13 using the cross-sectional approach, compared with 1.30 using the longitudinal approach (p = 0.17). Mean time to aspiration of fluid was 45.1 s using the cross-sectional approach and 52.8 s using the longitudinal approach (p = 0.43). The mean difficulty score out of 10 was 3.97 for the cross-sectional approach and 3.93 for the longitudinal approach (p = 0.95). We found no significant difference in effectiveness between the cross-sectional and longitudinal approaches to ultrasound-guided venepuncture when performed on a model. We believe that both approaches should be included when teaching ultrasound-guided peripheral vascular access. To confirm which approach would be best in clinical practice, we advocate future testing of both approaches on patients.

  17. Plantar fascia: imaging diagnosis and guided treatment.

    PubMed

    McNally, Eugene G; Shetty, Shilpa

    2010-09-01

    Plantar fasciopathy is a common cause of heel pain. This article covers the imaging anatomy of the hindfoot, the imaging findings on ultrasound and magnetic resonance imaging (MRI) of plantar fasciopathy, plantar fibromas, trauma, Achilles tendonopathy, neural compression, stress fractures of the os calcis and other heel pad lesions. Thickening of the plantar fascia insertion more than 5 mm either on ultrasound or MRI is suggestive of plantar fasciopathy. Ultrasound is superior to MRI for diagnosis of plantar fibroma as small low signal lesions on MRI are similar to the normal plantar fascia signal. Ultrasound demonstrates low echogenicity compared with the echogenic plantar fascia. Penetrating injuries can appear bizarre due to associated foreign body impaction and infection. Achilles tendonopathy can cause heel pain and should be considered as a possible diagnosis. Treatment options include physical therapy, ECSWT, corticosteroid injection, and dry needling. Percutaneous US guided treatment methods will be described. Thieme Medical Publishers.

  18. [Clinical application of ultrasound guided Fogarty balloon catheter in arterial crisis].

    PubMed

    Li, Xiaodong; Wang, Pei; Yu, Changyu; Yan, Xiaowei; Yin, Jing

    2017-10-01

    To explore the effectiveness of arterial crisis after replantation of limb treated by ultrasound guided Fogarty balloon catheter. Between January 2012 and July 2016, 27 patients suffered from arterial crisis after replantation of limb were treated with ultrasound guided Fogarty balloon catheter combined with thrombolytic anticoagulant. There were 18 males and 9 females with the age of 19-51 years (mean, 32 years). The limb mutilation position was at knee joint in 3 cases, lower limb in 9 cases, ankle joint in 6 cases, elbow joint in 2 cases, forearm in 4 cases, and wrist joint in 3 cases. The arterial crisis happened at 2.5-18 hours (mean, 7.5 hours) after limb replantation surgery. Color doppler ultrasonography was used to diagnose the arterial thrombosis, finally the anastomotic thrombosis were found in 16 cases, non-anastomotic thrombosis in 7 cases, and combined thrombosis in 4 cases. All the thrombosis were deteced in the arteries with the length of 0.8-3.9 cm. No complication such as vascular perforation, rupture, air embolism, thromboembolism, wound infection, or sepsis happened after operation. Arterial crisis occurred again in 3 cases at 1.5-13.5 hours after limb replantation and treated by arterial exploration, 1 case was treated successfully; 2 cases had arterial occlusion and partial necrosis of limb, and got amputation treatment at last. The rest 24 cases survived with the incision healing by first stage. In the 24 cases, 1 case suffered from acute myonephropathic metabolic syndrome and corrected after hemodialysis; 1 case suffered from acute liver functional damage and corrected by comprehensive treatment of internal medicine. The 24 patients were followed up 7-38 months (mean, 11 months). At last follow-up, blood supply of the limb was good with normal skin temperature and improved sense of feeling, activity, and swelling. According to Chinese Medical Association of hand surgery to the upper extremity function assessment standard, the results were

  19. Distribution of Injectate and Sensory-Motor Blockade After Adductor Canal Block.

    PubMed

    Gautier, Philippe E; Hadzic, Admir; Lecoq, Jean-Pierre; Brichant, Jean Francois; Kuroda, Maxine M; Vandepitte, Catherine

    2016-01-01

    The analgesic efficacy reported for the adductor canal block may be related to the spread of local anesthetic outside the adductor canal. Fifteen patients undergoing knee surgery received ultrasound-guided injections of local anesthetic at the level of the adductor hiatus. Sensory-motor block and spread of contrast solution were assessed. Sensation was rated as "markedly diminished" or "absent" in the saphenous nerve distribution and "slightly diminished" in the sciatic nerve territory without motor deficits. Contrast solution was found in the popliteal fossa. The spread of injectate to the popliteal fossa may contribute to the analgesic efficacy of adductor canal block.

  20. Ultrasound-guided minimally invasive surgery for achilles tendon rupture: preliminary results.

    PubMed

    Wang, Chen-Chie; Chen, Pei-Yu; Wang, Ting-Ming; Wang, Chung-Li

    2012-07-01

    Many surgeons prefer surgical repair for Achilles tendon ruptures in an attempt to reduce the risk of rerupture. To minimize wound complications, the use of minimally invasive surgery has become more popular recently. In line with this, the use of ultrasound to guide Achilles tendon repair is reported in this study. From March 2005 to January 2008, 23 patients with Achilles tendon rupture were repaired by the same surgeon. The ages of the patients ranged from 19 to 67 years old, with an average of 43 years old. The repair of the Achilles tendon was achieved through a stab wound under the guidance of ultrasonography. A control group consisted of 25 patients who received traditional open Achilles tendon repair. The average operation time was 52 minutes, and the average wound size was 1.1 cm. The short leg cast was removed 4 weeks after the surgery, and serial casting was used for another 3 to 4 weeks. The postoperative AOFAS ankle-hindfoot scores were 98.7 in the experimental group, 96.5 in the control group with no significant difference. The rates of local infection, stiffness of the ankle, pain of the scar and sural nerve injury were better in the experimental group than in the control group with significant difference. Ultrasound-guided surgery was a good choice due to its availability and real-time soft tissue visualization. It can further minimize the size of the surgical wound. Our method has the potential to achieve reliable results.

  1. Outcomes of percutaneous coronary intervention in intermediate coronary artery disease: fractional flow reserve-guided versus intravascular ultrasound-guided.

    PubMed

    Nam, Chang-Wook; Yoon, Hyuck-Jun; Cho, Yun-Kyeong; Park, Hyoung-Seob; Kim, Hyungseop; Hur, Seung-Ho; Kim, Yoon-Nyun; Chung, In-Sung; Koo, Bon-Kwon; Tahk, Seung-Jae; Fearon, William F; Kim, Kwon-Bae

    2010-08-01

    This study sought to evaluate the long-term clinical outcomes of a fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) strategy compared with intravascular ultrasound (IVUS)-guided PCI for intermediate coronary lesions. Both FFR- and IVUS-guided PCI strategies have been reported to be safe and effective in intermediate coronary lesions. The study included 167 consecutive patients, with intermediate coronary lesions evaluated by FFR or IVUS (FFR-guided, 83 lesions vs. IVUS-guided, 94 lesions). Cutoff value of FFR in FFR-guided PCI was 0.80, whereas that for minimal lumen cross sectional area in IVUS-guided PCI was 4.0 mm(2). The primary outcome was defined as a composite of major adverse cardiac events including death, myocardial infarction, and ischemia-driven target vessel revascularization at 1 year after the index procedure. Baseline percent diameter stenosis and lesion length were similar in both groups (51 +/- 8% and 24 +/- 12 mm in the FFR group vs. 52 +/- 8% and 24 +/- 13 mm in the IVUS group, respectively). However, the IVUS-guided group underwent revascularization therapy significantly more often (91.5% vs. 33.7%, p < 0.001). No significant difference was found in major adverse cardiac event rates between the 2 groups (3.6% in FFR-guided PCI vs. 3.2% in IVUS-guided PCI). Independent predictors for performing intervention were guiding device: FFR versus IVUS (relative risk [RR]: 0.02); left anterior descending coronary artery versus non-left anterior descending coronary artery disease (RR: 5.60); and multi- versus single-vessel disease (RR: 3.28). Both FFR- and IVUS-guided PCI strategy for intermediate coronary artery disease were associated with favorable outcomes. The FFR-guided PCI reduces the need for revascularization of many of these lesions. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Usefulness of rehabilitation in patients with rotator cuff calcific tendinopathy after ultrasound-guided percutaneous treatment.

    PubMed

    Abate, Michele; Schiavone, Cosima; Salini, Vincenzo

    2015-01-01

    To evaluate the efficacy of a specific rehabilitation program for patients in whom ultrasound-guided percutaneous treatment (UGPT) was performed for rotator cuff calcific tendinopathy (RCCT). In this prospective observational study, 86 patients (22 males and 64 females) with shoulder calcific tendinopathy treated with UGPT were enrolled. At the end of the procedure, a corticosteroid injection into the subacromial-subdeltoid bursa was performed. The patients were then asked to follow a specific rehabilitation protocol (2 times/week for 5 weeks) that focused on mobility, strength and function. At baseline and after 6 weeks, clinical parameters, visual analog scale (VAS) and Constant-Murley scale (CMS) scores and ultrasound (US) features were collected. The mean age of the patients was 48.9 ± 8.4 years and their mean BMI was 22.7 ± 2.1. Considering the whole cohort, the treatment was effective, with a significant decrease in the VAS score and an improvement in the CMS score. Thereafter, on the basis of the compliance to the rehabilitation program (by self-report), 53 and 33 patients were included in the rehabilitation group (Rehab group; performed exercises ≥2 times/week) and the No Rehab group (performed exercises <2 times/week), respectively. The comparison between the groups showed that the subjects who performed the exercises regularly had better results in terms of pain and functional recovery, and less associated diseases (e.g. adhesive bursitis and tenosynovitis of the long head of the biceps) than those who were less compliant with the program. UGPT, followed by a specific postprocedure rehabilitation program, was an effective treatment for RCCT. © 2014 S. Karger AG, Basel.

  3. Treatment efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation for benign thyroid nodules

    PubMed Central

    Li, Xiao-long; Lu, Feng; Yue, Wen-wen; Sun, Li-ping; Bo, Xiao-wan; Guo, Le-hang; Xu, Jun-mei; Liu, Bo-ji; Li, Dan-dan; Qu, Shen

    2016-01-01

    Objective: To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. Methods: The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150–T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. Results: In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47–16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510–17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. Conclusion: Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. Advances in knowledge: Based on the comparable efficacy and clinical

  4. Magnetic resonance-guided focused ultrasound treatment of facet joint pain: summary of preclinical phase

    PubMed Central

    2014-01-01

    Study design A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted to test the feasibility, safety, and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for treating facet joint pain. Objective The goal of the current study was to develop a novel method for accurate and safe noninvasive facet joint ablation using MRgFUS. Summary of background data Facet joints are a common source of chronic back pain. Direct facet joint interventions include medial branch nerve ablation and intra-articular injections, which are widely used, but limited in the short and long term. MRgFUS is a breakthrough technology that enables accurate delivery of high-intensity focused ultrasound energy to create a localized temperature rise for tissue ablation, using MR guidance for treatment planning and real-time feedback. Methods We validated the feasibility, safety, and efficacy of MRgFUS for facet joint ablation using the ExAblate 2000® System (InSightec Ltd., Tirat Carmel, Israel) and confirmed the system's ability to ablate the edge of the facet joint and all terminal nerves innervating the joint. A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted. Results The experiments showed that targeting the facet joint with energies of 150–450 J provides controlled and accurate heating at the facet joint edge without penetration to the vertebral body, spinal canal, or root foramina. Treating with reduced diameter of the acoustic beam is recommended since a narrower beam improves access to the targeted areas. Conclusions MRgFUS can safely and effectively target and ablate the facet joint. These results are highly significant, given that this is the first study to demonstrate the potential of MRgFUS to treat facet joint pain. PMID:24921048

  5. The advent of ultrasound-guided ablation techniques in nodular thyroid disease: towards a patient-tailored approach.

    PubMed

    Papini, Enrico; Pacella, Claudio M; Misischi, Irene; Guglielmi, Rinaldo; Bizzarri, Giancarlo; Døssing, Helle; Hegedus, Laszlo

    2014-08-01

    Surgery is the long-established therapeutic option for benign thyroid nodules, which steadily grow and become symptomatic. The cost of thyroid surgery, the risk of temporary or permanent complications, and the effect on quality of life, however, remain relevant concerns. Therefore, various minimally invasive treatments, directed towards office-based management of symptomatic nodules, without requiring general anaesthesia, and with negligible damage to the skin and cervical tissues, have been proposed during the past two decades. Today, ultrasound-guided percutaneous ethanol injection and thermal ablation with laser or radiofrequency have been thoroughly evaluated, and are accessible procedures in specialized centres. In clinical practice, relapsing thyroid cysts are effectively managed with percutaneous ethanol injection treatment, which should be considered therapy of choice. In solid non-functioning thyroid nodules that grow or become symptomatic, trained operators may safely induce, with a single session of laser ablation treatment or radiofrequency ablation, a 50% volume decrease and, in parallel, improve local symptoms. In contrast, hyperfunctioning nodules remain best treated with radioactive iodine, which results in a better control of hyperthyroidism, also in the long-term, and fewer side-effects. Currently, minimally invasive treatment is also investigated for achieving local control of small size neck recurrences of papillary thyroid carcinoma in patients who are poor candidates for repeat cervical lymph node dissection. This particular use should still be considered experimental. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Magnetic navigation in ultrasound-guided interventional radiology procedures.

    PubMed

    Xu, H-X; Lu, M-D; Liu, L-N; Guo, L-H

    2012-05-01

    To evaluate the usefulness of magnetic navigation in ultrasound (US)-guided interventional procedures. Thirty-seven patients who were scheduled for US-guided interventional procedures (20 liver cancer ablation procedures and 17 other procedures) were included. Magnetic navigation with three-dimensional (3D) computed tomography (CT), magnetic resonance imaging (MRI), 3D US, and position-marking magnetic navigation were used for guidance. The influence on clinical outcome was also evaluated. Magnetic navigation facilitated applicator placement in 15 of 20 ablation procedures for liver cancer in which multiple ablations were performed; enhanced guidance in two small liver cancers invisible on conventional US but visible at CT or MRI; and depicted the residual viable tumour after transcatheter arterial chemoembolization for liver cancer in one procedure. In four of 17 other interventional procedures, position-marking magnetic navigation increased the visualization of the needle tip. Magnetic navigation was beneficial in 11 (55%) of 20 ablation procedures; increased confidence but did not change management in five (25%); added some information but did not change management in two (10%); and made no change in two (10%). In the other 17 interventional procedures, the corresponding numbers were 1 (5.9%), 2 (11.7%), 7 (41.2%), and 7 (41.2%), respectively (p=0.002). Magnetic navigation in US-guided interventional procedure provides solutions in some difficult cases in which conventional US guidance is not suitable. It is especially useful in complicated interventional procedures such as ablation for liver cancer. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Ultrasound-Guided Transesophageal High-Intensity Focused Ultrasound Cardiac Ablation in a Beating Heart: A Pilot Feasibility Study in Pigs.

    PubMed

    Bessiere, Francis; N'djin, W Apoutou; Colas, Elodie Constanciel; Chavrier, Françoise; Greillier, Paul; Chapelon, Jean Yves; Chevalier, Philippe; Lafon, Cyril

    2016-08-01

    Catheter ablation for the treatment of arrhythmia is associated with significant complications and often-repeated procedures. Consequently, a less invasive and more efficient technique is required. Because high-intensity focused ultrasound (HIFU) enables the generation of precise thermal ablations in deep-seated tissues without harming the tissues in the propagation path, it has the potential to be used as a new ablation technique. A system capable of delivering HIFU into the heart by a transesophageal route using ultrasound (US) imaging guidance was developed and tested in vivo in six male pigs. HIFU exposures were performed on atria and ventricles. At the time of autopsy, visual inspection identified thermal lesions in the targeted areas in three of the animals. These lesions were confirmed by histologic analysis (mean size: 5.5 mm(2) × 11 mm(2)). No esophageal thermal injury was observed. One animal presented with bradycardia due to an atrio-ventricular block, which provides real-time confirmation of an interaction between HIFU and the electrical circuits of the heart. Thus, US-guided HIFU has the potential to minimally invasively create myocardial lesions without an intra-cardiac device. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. High-flow vascular malformation treatment using ultrasound-guided laser combined with polidocanol sclerotherapy.

    PubMed

    Zhang, Yan; Zhou, Ping; Li, Lan; Li, Jia-le

    2015-07-01

    The current treatment for vascular malformations includes surgery, sclerotherapy, and embolization. However, each method has its limitations, such as recurrence, complications, scarring, and radiation exposure. Therefore, identifying an effective, minimally invasive treatment that reduces lesion recurrence is particularly important. We describe in detail a patient who received treatment with ultrasound-guided laser interruption of feeding vessels combined with polidocanol sclerotherapy after the recurrence of forearm high-flow vascular malformation.

  9. Percutaneous ultrasound-guided vs. intraoperative rectus sheath block for pediatric umbilical hernia repair: A randomized clinical trial.

    PubMed

    Litz, Cristen N; Farach, Sandra M; Fernandez, Allison M; Elliott, Richard; Dolan, Jenny; Patel, Nikhil; Zamora, Lillian; Colombani, Paul M; Walford, Nebbie E; Amankwah, Ernest K; Snyder, Christopher W; Danielson, Paul D; Chandler, Nicole M

    2017-06-01

    Regional anesthesia is commonly used in children. Our hypothesis was that percutaneous ultrasound-guided (PERC) rectus sheath blocks would result in lower postoperative pain scores compared to intraoperative (IO) rectus sheath blocks following umbilical hernia repair. A single-institution randomized blinded trial was conducted in pediatric patients undergoing elective umbilical hernia repair. The primary outcome was mean postoperative Wong-Baker pain score. Secondary outcomes included narcotic requirements and length of postoperative stay. Fifty-eight patients were included: 28 PERC and 30 IO. Operating room time was significantly longer in the PERC group (41 vs. 35min, p<0.01). Mean postoperative pain scores (PERC-2.6 vs. IO-3.3, p=0.11), morphine equivalents intraoperatively (PERC-0 vs. IO-0.04mg/kg, p=0.29) and postoperatively (PERC-0.04 vs. IO-0.09mg/kg, p=0.17), time to first postoperative narcotic dose (PERC-30 vs. IO-22min, p=0.33, log-rank test), and postoperative length of stay (PERC-76 vs. IO-80min, p=0.44) were similar. Following umbilical hernia repair in children, percutaneous ultrasound-guided and intraoperative rectus sheath blocks resulted in similar mean postoperative pain scores. There were no differences in secondary outcomes such as time to first narcotic, narcotic requirements, and length of stay. The additional resources required to complete a percutaneous ultrasound-guided rectus sheath block may not be warranted. Randomized controlled trial. Level I. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Endoscopic ultrasound-guided techniques for diagnosing pancreatic mass lesions: Can we do better?

    PubMed Central

    Storm, Andrew C; Lee, Linda S

    2016-01-01

    The diagnostic approach to a possible pancreatic mass lesion relies first upon various non-invasive imaging modalities, including computed tomography, ultrasound, and magnetic resonance imaging techniques. Once a suspect lesion has been identified, tissue acquisition for characterization of the lesion is often paramount in developing an individualized therapeutic approach. Given the high prevalence and mortality associated with pancreatic cancer, an ideal approach to diagnosing pancreatic mass lesions would be safe, highly sensitive, and reproducible across various practice settings. Tools, in addition to radiologic imaging, currently employed in the initial evaluation of a patient with a pancreatic mass lesion include serum tumor markers, endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA). EUS-FNA has grown to become the gold standard in tissue diagnosis of pancreatic lesions. PMID:27818584

  11. Ultrasound-mediated nanoparticle delivery across ex vivo bovine retina after intravitreal injection.

    PubMed

    Huang, Di; Chen, Ying-Shan; Thakur, Sachin S; Rupenthal, Ilva D

    2017-10-01

    Intravitreal injection is the most common administration route for the treatment of retinal diseases. However, the vitreous and some of the retinal layers themselves act as significant barriers to efficient delivery of drugs administered intravitreally. This study aimed to improve the diffusive mobility of nanoparticles (NPs) in the vitreous and enhance their permeation across the retina after intravitreal injection by application of ultrasound (US). Ex vivo posterior bovine eye cups were used and the vitreous was either left intact or removed gently from the neural retina. Hyaluronic acid coated human serum albumin NPs were administered into the eye cups and continuous US with a frequency of 1MHz, an intensity of 0.5W/cm 2 , and a duration of 30s was applied once or repeatedly via the transscleral route. After pre-determined time points, fluorescence intensities in the vitreous and the retina were analyzed. Short pulses of US significantly improved the diffusive mobility of NPs through the vitreous as well as their penetration across the neural retina into the retinal pigment epithelium and choroid without causing any detectable damage to the ocular tissues. Therefore, transscleral US could be a powerful and safe tool to enhance retinal delivery of intravitreally injected NPs. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Medial approach of ultrasound-guided costoclavicular plexus block and its effects on regional perfussion.

    PubMed

    Nieuwveld, D; Mojica, V; Herrera, A E; Pomés, J; Prats, A; Sala-Blanch, X

    2017-04-01

    Ultrasound-guided infraclavicular block in the costoclavicular space located between the clavicle and the first rib, reaches the secondary trunks when they are clustered together and lateral to the axillary artery. This block is most often performed through a lateral approach, the difficulty being finding the coracoid process an obstacle and guiding the needle towards the vessels and pleura. A medial approach, meaning from inside to outside, will avoid these structures. Traditionally the assessment of a successful block is through motor or sensitive responses but a sympathetic fibre block can also be evaluated measuring the changes in humeral artery blood flow, skin temperature and/or perfusion index. To describe the medial approach of the ultrasound-guided costoclavicular block evaluating its development by motor and sensitive response and measurement of sympathetic changes. Description of the technique and administration of 20ml of contrast in a fresh cadaver model, evaluating the distribution with CT-scan and sagittal sections of the anatomic piece. Subsequently in a clinical phase, including 11 patients, we evaluated the establishment of motor, sensitive and sympathetic blocks. We evaluated the sympathetic changes reflected by humeral artery blood flow, skin temperature and distal perfusion index. In the anatomical model the block was conducted without difficulties, showing an adequate periclavicular distribution of the contrast in the CT-scan and in sagittal sections, reaching the interscalenic space as far as the secondary trunks. Successful blocks were observed in 91% of patients after 25minutes. All the parameters reflecting sympathetic block increased significantly. The humeral artery blood flow showed an increase from 108 ± 86 to 188±141ml/min (P=.05), skin temperature from 32.1±2 to 32.8±9°C (P=.03) and perfusion index from 4±3 to 9±5 (P=.003). The medial approach of the ultrasound-guided costoclavicular block is anatomically feasible, with high

  13. Management of hypertrophic pylorus stenosis with ultrasound guided single shot epidural anaesthesia--a retrospective analysis of 20 cases.

    PubMed

    Willschke, Harald; Machata, Anette-Marie; Rebhandl, Winfried; Benkoe, Thomas; Kettner, Stephan C; Brenner, Lydia; Marhofer, Peter

    2011-02-01

    To retrospectively describe the performance of ultrasound guided thoracic epidural anaesthesia under sedation for anaesthesia management of open pyloromyotomy. Anaesthesia management for hypertrophic pylorus stenosis (HPS) is usually performed under general anaesthesia with tracheal intubation. Only a few publications describe avoidance of tracheal intubation in infants by using spinal or caudal anaesthesia. The present retrospective analysis describes the performance of ultrasound guided thoracic epidural anaesthesia under sedation for anaesthetic management of open pyloromyotomy. Twenty consecutive infants scheduled for pyloromyotomy according to the Weber-Ramstedt technique were retrospectively analysed. After sedation with nalbuphine and propofol, an ultrasound guided single shot thoracic epidural anaesthesia was performed with 0.75 ml·kg(-1) ropivacaine 0.475%. Insufficient blockade was defined as increase of HR > 15% from initial value and/or any movements at skin incision. In those cases we were prepared for rapid sequence intubation according to the departmental standard. All pyloromyotomies could be performed under single shot thoracic epidural anaesthesia and sedation. One case of moderate oxygen desaturation was treated with intermittent ventilation via face mask. Thoracic epidural anaesthesia under sedation for pyloromyotomy has been a useful technique in this retrospective series of infants suffering from HPS. In 1/20 infants short term assisted ventilation via face mask was required. Undisturbed surgery was possible in all cases. © 2010 Blackwell Publishing Ltd.

  14. Canine Lipomas Treated with Steroid Injections: Clinical Findings

    PubMed Central

    Lamagna, Barbara; Greco, Adelaide; Guardascione, Anna; Navas, Luigi; Ragozzino, Manuela; Paciello, Orlando; Brunetti, Arturo; Meomartino, Leonardo

    2012-01-01

    Lipomas are common benign tumours of fat cells. In most cases, surgical excision is curative and simple to perform; however, such a procedure requires general anaesthesia and may be associated with delayed wound healing, seroma formation and nerve injury in deep and intramuscular tumours. The objective of this study was to evaluate treatment of subcutaneous, subfascial or intermuscular lipomas using intralesional steroid injections in dogs. Fifteen dogs presenting with lipomas were selected for treatment with ultrasound-guided intralesional injection of triamcinolone acetonide at a dose of 40 mg/mL. Nine subcutaneous and subfascial tumours showed a complete regression. The other lipomas decreased in diameter, achieving, in some cases, remission of discomfort and regression of lameness. Steroid injection was a relatively safe and effective treatment for lipomas in dogs; only six dogs experienced polyuria/polydipsia for about 2 weeks post-treatment. PMID:23226250

  15. Ultrasound-guided stellate ganglion blocks combined with pharmacological and occupational therapy in Complex Regional Pain Syndrome (CRPS): a pilot case series ad interim.

    PubMed

    Wei, Karin; Feldmann, Robert E; Brascher, Anne-Kathrin; Benrath, Justus

    2014-12-01

    This preliminary and retrospective pilot case series examines a treatment concept consisting of ultrasound-guided stellate ganglion blocks (SGBs) combined with pharmacological and occupational therapy in patients with complex regional pain syndrome (CRPS) of the hand. Efficacy of combined treatment concepts and safety of ultrasound-guided SGB have not been sufficiently investigated yet. A total number of 156 blocks were evaluated in 16 patients with CRPS in a retrospective analysis. All patients received pharmacotherapy and a standard regimen of occupational therapy offered simultaneously to the SGBs. Changes in both spontaneous and evoked pain levels were assessed by numerical pain rating score before and after the last blockade of a series. Side effects were documented. The overall mean pain reduction was 63.2% regarding spontaneous and 45.3% regarding evoked pain. Mild complications, such as hoarseness or dysphagia, occurred in 13.5% of the blocks (21 SGBs). Serious complications, such as plexus paresis or accidental puncture of vessels or other structures, did not occur. Time between symptom onset and start of treatment did not affect the extent of pain reduction. The combination of ultrasound-guided SGB and simultaneous pharmacological and occupational therapy showed encouraging treatment results under conditions of this pilot case series. Assessment of efficacy of this combined treatment concept and safety of ultrasound-guided SGB require further prospective clinical studies with larger number of participants. Wiley Periodicals, Inc.

  16. Ultrasound biomicroscopy in mouse cardiovascular development

    NASA Astrophysics Data System (ADS)

    Turnbull, Daniel H.

    2004-05-01

    The mouse is the preferred animal model for studying mammalian cardiovascular development and many human congenital heart diseases. Ultrasound biomicroscopy (UBM), utilizing high-frequency (40-50-MHz) ultrasound, is uniquely capable of providing in vivo, real-time microimaging and Doppler blood velocity measurements in mouse embryos and neonates. UBM analyses of normal and abnormal mouse cardiovascular function will be described to illustrate the power of this microimaging approach. In particular, real-time UBM images have been used to analyze dimensional changes in the mouse heart from embryonic to neonatal stages. UBM-Doppler has been used recently to examine the precise timing of onset of a functional circulation in early-stage mouse embryos, from the first detectable cardiac contractions. In other experiments, blood velocity waveforms have been analyzed to characterize the functional phenotype of mutant mouse embryos having defects in cardiac valve formation. Finally, UBM has been developed for real-time, in utero image-guided injection of mouse embryos, enabling cell transplantation and genetic gain-of-function experiments with transfected cells and retroviruses. In summary, UBM provides a unique and powerful approach for in vivo analysis and image-guided manipulation in normal and genetically engineered mice, over a wide range of embryonic to neonatal developmental stages.

  17. New piezocrystal material in the development of a 96-element array transducer for MR-guided focused ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Qiu, Zhen; Habeshaw, Roderick; Fortine, Julien; Huang, Zhihong; Démoré, Christine; Cochran, Sandy

    2012-11-01

    Piezocrystal materials have been recognized as having better performance than piezoelectric ceramics, and have thus been widely adopted in ultrasound imaging arrays. Although their behaviour is susceptible to temperature and pressure, their large electromechanical coupling coefficients and other excellent piezoelectric properties also offer the potential for further improvements in the efficiency of therapeutic ultrasound transducers. Furthermore, new piezocrystals with modified compositions have been developed recently to increase their tolerance to temperature and pressure. In this work, a prototype of faceted bowl transducer was designed and manufactured as a proof of concept to explore practical issues associated with adoption of piezocrystals for magnetic resonance imaging guided focused ultrasound surgery.

  18. Intravascular ultrasound guided wiring re-entry technique for complex chronic total occlusions.

    PubMed

    Huang, Wei-Chieh; Teng, Hsin-I; Hsueh, Chien-Hung; Lin, Shing-Jong; Chan, Wan-Leong; Lu, Tse-Min

    2018-05-03

    The successful recanalization rate of chronic total occlusion (CTO) lesions without retrograde collaterals available is always low. Intravascular ultrasound (IVUS) may be useful to guide the subintimal guidewire to re-enter the true lumen. We evaluated the clinical feasibility and efficacy of the IVUS-guided wiring re-entry technique for these complex CTO lesions. Twenty consecutive patients (19 male, mean age: 65.3 ± 12.8 years) with both failed antegrade and retrograde approaches were enrolled. The IVUS catheter was introduced into the subintimal space to identify the entry point into the subintimal space, and guide another stiff wire to re-enter the true lumen with the adjacent side-branch or first wire as markers, or using IVUS-guided parallel wire technique. The entry point into the subintimal space was identified by IVUS in all cases, and the IVUS-guided wiring re-entry technique succeeded in 17 cases (85%). No procedure-related complication was noted except one case of delayed cardiac tamponade due to the wire perforation. During the mean follow-up period of 1.9 ± 1.3 years, there was no adverse cardiac event, except one patient died of the complication of cardiac transplantation. The IVUS-guided wiringre-entry technique might be feasible and safe for the recanalization of complex CTO lesions. © 2018, Wiley Periodicals, Inc.

  19. Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Gibson, Eli; Uribarri, Laura; Keane, Geri; Gurusami, Kurinchi; Davidson, Brian; Pereira, Stephen P; Clarkson, Matthew J; Barratt, Dean C

    2018-06-01

    Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method. A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ([Formula: see text]) or retrospective clinical ([Formula: see text]) EUS landmarks. The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value [Formula: see text]). The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.

  20. Use of the cumulative sum method (CUSUM) to assess the learning curves of ultrasound-guided continuous femoral nerve block.

    PubMed

    Kollmann-Camaiora, A; Brogly, N; Alsina, E; Gilsanz, F

    2017-10-01

    Although ultrasound is a basic competence for anaesthesia residents (AR) there is few data available on the learning process. This prospective observational study aims to assess the learning process of ultrasound-guided continuous femoral nerve block and to determine the number of procedures that a resident would need to perform in order to reach proficiency using the cumulative sum (CUSUM) method. We recruited 19 AR without previous experience. Learning curves were constructed using the CUSUM method for ultrasound-guided continuous femoral nerve block considering 2 success criteria: a decrease of pain score>2 in a [0-10] scale after 15minutes, and time required to perform it. We analyse data from 17 AR for a total of 237 ultrasound-guided continuous femoral nerve blocks. 8/17 AR became proficient for pain relief, however all the AR who did more than 12 blocks (8/8) became proficient. As for time of performance 5/17 of AR achieved the objective of 12minutes, however all the AR who did more than 20 blocks (4/4) achieved it. The number of procedures needed to achieve proficiency seems to be 12, however it takes more procedures to reduce performance time. The CUSUM methodology could be useful in training programs to allow early interventions in case of repeated failures, and develop competence-based curriculum. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.