Sample records for ultrasound-guided central venous

  1. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  2. Ultrasound-guided venous access for pacemakers and defibrillators.

    PubMed

    Seto, Arnold H; Jolly, Aaron; Salcedo, Jonathan

    2013-03-01

    Ultrasound guidance is widely recommended to reduce the risk of complications during central venous catheter placement. However, ultrasound guidance is not commonly utilized for implanting leads for cardiac rhythm management devices. We describe our technique of ultrasound-guided pacemaker implantation, including a novel pull-through technique that allows percutaneous guidewire insertion prior to the first incision. We review the literature and recent advances in ultrasound imaging technology that may facilitate the adoption of ultrasound guidance. Ultrasound guidance provides a safe and rapid technique for extrathoracic subclavian or axillary venous lead placement. © 2012 Wiley Periodicals, Inc.

  3. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    PubMed

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  4. Evaluation of cost-effectiveness from the funding body's point of view of ultrasound-guided central venous catheter insertion compared with the conventional technique.

    PubMed

    Noritomi, Danilo Teixeira; Zigaib, Rogério; Ranzani, Otavio T; Teich, Vanessa

    2016-01-01

    To evaluate the cost-effectiveness, from the funding body's point of view, of real-time ultrasound-guided central venous catheter insertion compared to the traditional method, which is based on the external anatomical landmark technique. A theoretical simulation based on international literature data was applied to the Brazilian context, i.e., the Unified Health System (Sistema Único de Saúde - SUS). A decision tree was constructed that showed the two central venous catheter insertion techniques: real-time ultrasonography versus external anatomical landmarks. The probabilities of failure and complications were extracted from a search on the PubMed and Embase databases, and values associated with the procedure and with complications were taken from market research and the Department of Information Technology of the Unified Health System (DATASUS). Each central venous catheter insertion alternative had a cost that could be calculated by following each of the possible paths on the decision tree. The incremental cost-effectiveness ratio was calculated by dividing the mean incremental cost of real-time ultrasound compared to the external anatomical landmark technique by the mean incremental benefit, in terms of avoided complications. When considering the incorporation of real-time ultrasound and the concomitant lower cost due to the reduced number of complications, the decision tree revealed a final mean cost for the external anatomical landmark technique of 262.27 Brazilian reals (R$) and for real-time ultrasound of R$187.94. The final incremental cost of the real-time ultrasound-guided technique was -R$74.33 per central venous catheter. The incremental cost-effectiveness ratio was -R$2,494.34 due to the pneumothorax avoided. Real-time ultrasound-guided central venous catheter insertion was associated with decreased failure and complication rates and hypothetically reduced costs from the view of the funding body, which in this case was the SUS.

  5. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education

    PubMed Central

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J.A.; Dandorf, Stewart J.; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-01-01

    Introduction Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. Methods This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Results Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). Conclusion The use of this novel cadaver

  6. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    PubMed

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). The use of this novel cadaver model prevented extravasation of fluid

  7. Cross sectional survey of ultrasound use for central venous catheter insertion among resident physicians.

    PubMed

    Nomura, Jason T; Sierzenski, Paul R; Nace, Jason E; Bollinger, Melissa

    2008-07-01

    Use of ultrasound guidance for Central Venous Catheter insertion has been associated with decreased complications and increased success rates. Previous reports show low rates of use among physicians. Evaluation of the frequency of Ultrasound Guidance use for Central Venous Catheter insertion among residents at a teaching institution. A cross sectional electronic survey of resident physicians at a tertiary care teaching hospital was conducted to evaluate use of Ultrasound Guidance for Central Venous Catheterization. Assessment included self reported frequency of ultrasound guidance use, and volume of central venous catheter placement. Attitudes toward the use of ultrasound were assessed using Likert scales. There is a high rate. over 90%, of ultrasound guidance use for Internal Jugular central venous catheters among residents. The majority of residents use sterile real-time imaging with a single operator with a reported success rate greater then 80%. Resident use of ultrasound guidance for Internal Jugular central venous catheter insertion can be much higher than previously reported in the literature.

  8. Ultrasound-guided central venous access using Google Glass.

    PubMed

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Sonothrombolysis of Intra-Catheter Aged Venous Thrombi Using Microbubble Enhancement and Guided Three Dimensional Ultrasound Pulses

    PubMed Central

    Kutty, Shelby; Xie, Feng; Gao, Shunji; Drvol, Lucas K; Lof, John; Fletcher, Scott E; Radio, Stanley J; Danford, David A; Hammel, James M; Porter, Thomas R

    2010-01-01

    Central venous and arterial catheters are a major source of thrombo-embolic disease in children. We hypothesized that guided high mechanical index (MI) impulses from diagnostic three-dimensional (3D) ultrasound during an intravenous microbubble infusion could dissolve these thrombi. An in vitro system simulating intra-catheter thrombi was created and then treated with guided high MI impulses from 3D ultrasound, utilizing low MI microbubble sensitive imaging pulse sequence schemes to detect the microbubbles (Perflutren Lipid Microsphere, Definity®, Lantheus). Ten aged thrombi over 24 hours old were tested using 3D ultrasound coupled with a continuous diluted microbubble infusion (Group A), and ten with 3D ultrasound alone (Group B). Mean thrombus age was 28.6 hours (range 26.6–30.3). Groups A exhibited a 55 ± 19 % reduction in venous thrombus size, compared to 31±10 % for Group B (p=0.008). Feasibility testing was performed in 4 pigs, establishing a model to further investigate the efficacy. Sonothrombolysis of aged intra-catheter venous thrombi can be achieved with commercially available microbubbles and guided high MI ultrasound from a diagnostic 3D transducer. PMID:20696549

  10. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    PubMed

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  11. Detection of an embolized central venous catheter fragment with endobronchial ultrasound.

    PubMed

    Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L

    2018-01-01

    An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.

  12. Guidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization. Methods/Design The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections. Discussion The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications. Trial registration ClinicalTrials.gov Identifier: NCT01888094 PMID:24885789

  13. Location of the Central Venous Catheter Tip With Bedside Ultrasound in Young Children: Can We Eliminate the Need for Chest Radiography?

    PubMed

    Alonso-Quintela, Paula; Oulego-Erroz, Ignacio; Rodriguez-Blanco, Silvia; Muñiz-Fontan, Manoel; Lapeña-López-de Armentia, Santiago; Rodriguez-Nuñez, Antonio

    2015-11-01

    To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. Prospective observational study. PICU of a university hospital. Patients aged 0-14 who required a central venous catheter. None. Central venous catheter tip location was confirmed by ultrasound and chest radiography. Central venous catheters were classified as intra-atrial or extra-atrial according to their positions in relation to the cavoatrial junction. Central venous catheters located outside the vena cava were considered malpositioned. The distance between the catheter tip and the cavoatrial junction was measured. The time elapsed from image capture to interpretation was recorded. Fifty-one central venous catheters in 40 patients were analyzed. Chest radiography and ultrasound results agreed 94% of the time (κ coefficient, 0.638; p < 0.001) in determining intra-atrial and extra-atrial locations and 92% of the time in determining the diagnosis of central venous catheter malposition (κ coefficient, 0.670; p < 0.001). Chest radiography indicated a greater distance between the central venous catheter tip and the cavoatrial junction than measured by ultrasound, with a mean difference of 0.38 cm (95% CI, +0.27, +0.48 cm). Three central venous catheters were classified as extra-atrial by chest radiography but as intra-atrial by ultrasound. To locate the central venous catheter tip, ultrasound required less time than chest radiography (22.96 min [20.43 min] vs 2.23 min [1.06 min]; p < 0.001). Bedside ultrasound showed a good agreement with chest radiography in detecting central venous catheter tip location and revealing incorrect positions. Ultrasound could be a preferable method for routine verification of central venous catheter tip and can contribute to increased patient safety.

  14. Diagnostic accuracy of central venous catheter confirmation by bedside ultrasound versus chest radiography in critically ill patients: A systematic review and meta-analysis

    PubMed Central

    Ablordeppey, Enyo A.; Drewry, Anne M.; Beyer, Alexander B.; Theodoro, Daniel L.; Fowler, Susan A.; Fuller, Brian M.; Carpenter, Christopher R.

    2016-01-01

    Objective We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared to chest radiography. Data Sources PubMed, EMBASE, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov Study Selection Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2×2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, inter-rater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis 15 studies with 1553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 [0.77, 0.86] and 0.98 [0.97, 0.99] respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 [14.72, 65.78] and 0.25 [0.13, 0.47]. The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition

  15. Diagnostic Accuracy of Central Venous Catheter Confirmation by Bedside Ultrasound Versus Chest Radiography in Critically Ill Patients: A Systematic Review and Meta-Analysis.

    PubMed

    Ablordeppey, Enyo A; Drewry, Anne M; Beyer, Alexander B; Theodoro, Daniel L; Fowler, Susan A; Fuller, Brian M; Carpenter, Christopher R

    2017-04-01

    We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than

  16. Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center

    PubMed Central

    Ahn, Se Jin; Chung, Jin Wook; An, Sang Bu; Yin, Yong Hu; Jae, Hwan Jun; Park, Jae Hyung

    2012-01-01

    Objective To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. Results A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). Conclusion Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate. PMID:22563269

  17. The Barriers and Facilitators to Transfer of Ultrasound-Guided Central Venous Line Skills From Simulation to Practice: Exploring Perceptions of Learners and Supervisors.

    PubMed

    Mema, Briseida; Harris, Ilene

    2016-01-01

    PHENOMENON: Ultrasound-guided central venous line insertion is currently the standard of care. Randomized controlled trials and systematic reviews show that simulation is superior to apprenticeship training. The purpose of this study is to explore, from the perspectives of participants in a simulation-training program, the factors that help or hinder the transfer of skills from simulation to practice. Purposeful sampling was used to select and study the experience and perspective of novice fellows after they had completed simulation training and then performed ultrasound-guided central venous line in practice. Seven novice pediatric intensive care unit fellows and six supervising faculty in a university-affiliated academic center in a large urban city were recruited between September 2012 and January 2013. We conducted a qualitative study using semistructured interviews as our data source, employing a constructivist, grounded theory methodology. Both curricular and real-life factors influence the transfer of skills from simulation to practice and the overall performance of trainees. Clear instructions, the opportunity to practice to mastery, one-on-one observation with feedback, supervision, and further real-life experiences were perceived as factors that facilitated the transfer of skills. Concern for patient welfare, live trouble shooting, complexity of the intensive care unit environment, and the procedure itself were perceived as real-life factors that hindered the transfer of skills. Insights: As more studies confirm the superiority of simulation training versus apprenticeship training for initial student learning, the faculty should gain insight into factors that facilitate and hinder the transfer of skills from simulation to bedside settings and impact learners' performances. As simulation further augments clinical learning, efforts should be made to modify the curricular and bedside factors that facilitate transfer of skills from simulation to practice

  18. Ultrasound-Guided Vascular Access Simulator for Medical Training: Proposal of a Simple, Economic and Effective Model.

    PubMed

    Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio

    2017-03-01

    To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.

  19. Risk factors for acute adverse events during ultrasound-guided central venous cannulation in the emergency department.

    PubMed

    Theodoro, Daniel; Krauss, Missy; Kollef, Marin; Evanoff, Bradley

    2010-10-01

    Ultrasound (US) greatly facilitates cannulation of the internal jugular vein. Despite the ability to visualize the needle and anatomy, adverse events still occur. The authors hypothesized that the technique has limitations among certain patients and clinical scenarios. The purpose of this study was to identify characteristics of adverse events surrounding US-guided central venous cannulation (CVC). The authors assembled a prospective observational cohort of emergency department (ED) patients undergoing consecutive internal jugular CVC with US. The primary outcome of interest was a composite of acute mechanical adverse events including hematoma, arterial cannulation, pneumothorax, and unsuccessful placement. Physicians performing the CVC recorded anatomical site, reason for insertion, and acute complications. The patients with catheters were followed until the catheters were removed based on radiographic evidence or hospital nursing records. ED charts and pharmacy records contributed variables of interest. A self-reported online survey provided physician experience information. Logistic regression was used to calculate the odds of an adverse outcome.   Physicians attempted 289 CVCs on 282 patients. An adverse outcome occurred in 57 attempts (19.7%, 95% confidence interval [CI] = 15.5 to 24.7), the most common being 31 unsuccessful placements (11%, 95% CI = 7.7 to 14.8). Patients with a history of end-stage renal disease (odds ratio [OR] = 3.54, 95% CI = 1.59 to 7.89), and central lines placed by operators with intermediate experience (OR = 2.26, 95% CI = 1.19 to 4.32), were most likely to encounter adverse events. Previously cited predictors such as body mass index (BMI), coagulopathy, and pulmonary hyperinflation were not significant in our final model. Acute adverse events occurred in approximately one-fifth of US-guided internal jugular central line attempts. The study identified both patient (history of end-stage renal disease) and physician (intermediate

  20. Transitioning from anatomic landmarks to ultrasound guided central venous catheterizations: guidelines applied to clinical practice.

    PubMed

    Oom, Rodrigo; Casaca, Rui; Barroca, Rita; Carvalhal, Sara; Santos, Catarina; Abecasis, Nuno

    2017-07-14

    Centrally inserted central catheter (CICC) insertion is a commonly performed procedure that may give rise to different complications. Despite the suggestion of guidelines to use ultrasound guidance (USG) for vascular access, not all centers use it systematically. The aim of this study is to illustrate the experience with ultrasound in CICC placement at a high-volume oncological center, in a country where the landmark technique is standard. Retrospective analysis of a prospective database was performed on CICC placement under USG in the Central Venous Catheter Unit of Instituto Português de Oncologia de Lisboa Francisco Gentil, from 2012 to 2015. Three thousand five hundred and seventy-two procedures were recorded. From 2728 CICC placements, 1187 (43.5%) were done using USG. The majority of CICC placements were successful without immediate complications (96.1%). In 55 cases (4.6%), more than three attempts were necessary to puncture the vein. Pneumothorax occurred in 5 cases (0.4%) and arterial puncture was registered in 41 cases (3.5%). An increasing use of USG for placing CICCs was planned and observed over the years and, in the last year of the study, 67.3% of the CICC placements were with USG. CICC placement with USG is a safe and effective technique. Despite some resistance that is observed, these results support that it is worth following the guidelines that advocate the use of the USG in the placement of CICC.

  1. [Ultrasound-guided peripheral catheterization].

    PubMed

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  2. Randomized comparison of three transducer orientation approaches for ultrasound guided internal jugular venous cannulation.

    PubMed

    Batllori, M; Urra, M; Uriarte, E; Romero, C; Pueyo, J; López-Olaondo, L; Cambra, K; Ibáñez, B

    2016-03-01

    Ultrasound-guided internal jugular venous access increases the rate of successful cannulation and reduces the incidence of complications, compared with the landmark technique. Three transducer orientation approaches have been proposed for this procedure: short-axis (SAX), long-axis (LAX) and oblique-axis (OAX). Our goal was to assess and compare the performance of these approaches. A prospective randomized clinical trial was conducted in one teaching hospital. Patients aged 18 yr or above, who were undergoing ultrasound-guided internal jugular cannulation, were randomly assigned to one of three intervention groups: SAX, LAX and OAX group. The main outcome measure was successful cannulation on first needle pass. Incidence of mechanical complications was also registered. Restricted randomization was computer-generated. In total, 220 patients were analysed (SAX n=73, LAX n=75, OAX n=72). Cannulation was successful on first needle pass in 51 (69.9%) SAX patients, 39 (52%) LAX patients and 53 (73.6%) OAX patients. First needle pass failure was higher in the LAX group than in the OAX group (adjusted OR 3.7, 95% CI 1.71-8.0, P=0.002). A higher mechanical complication rate was observed in the SAX group (15.1%) than in the OAX (6.9%) and LAX (4%) groups (P=0.047). As OAX showed a higher first needle pass success rate than LAX and a lower mechanical complications rate than SAX, we recommend it as the standard approach when performing ultrasound-guided internal jugular venous access. Further clinical studies are needed to confirm this conclusion. NCT 01966354. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. A descriptive comparison of ultrasound-guided central venous cannulation of the internal jugular vein to landmark-based subclavian vein cannulation.

    PubMed

    Theodoro, Daniel; Bausano, Brian; Lewis, Lawrence; Evanoff, Bradley; Kollef, Marin

    2010-04-01

    The safest site for central venous cannulation (CVC) remains debated. Many emergency physicians (EPs) advocate the ultrasound-guided internal jugular (USIJ) approach because of data supporting its efficiency. However, a number of physicians prefer, and are most comfortable with, the subclavian (SC) vein approach. The purpose of this study was to describe adverse event rates among operators using the USIJ approach, and the landmark SC vein approach without US. This was a prospective observational trial of patients undergoing CVC of the SC or internal jugular veins in the emergency department (ED). Physicians performing the procedures did not undergo standardized training in either technique. The primary outcome was a composite of adverse events defined as hematoma, arterial cannulation, pneumothorax, and failure to cannulate. Physicians recorded the anatomical site of cannulation, US assistance, indications, and acute complications. Variables of interest were collected from the pharmacy and ED record. Physician experience was based on a self-reported survey. The authors followed outcomes of central line insertion until device removal or patient discharge. Physicians attempted 236 USIJ and 132 SC cannulations on 333 patients. The overall adverse event rate was 22% with failure to cannulate being the most common. Adverse events occurred in 19% of USIJ attempts, compared to 29% of non-US-guided SC attempts. Among highly experienced operators, CVCs placed at the SC site resulted in more adverse events than those performed using USIJ (relative risk [RR] = 1.89, 95% confidence interval [CI] = 1.05 to 3.39). While limited by observational design, our results suggest that the USIJ technique may result in fewer adverse events compared to the landmark SC approach.

  4. Long-axis view for ultrasound-guided central venous catheter placement via the internal jugular vein.

    PubMed

    Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus

    2016-04-01

    In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.

  5. Supraclavicular Approach to Ultrasound-Guided Brachiocephalic Vein Cannulation in Children and Neonates

    PubMed Central

    Merchaoui, Zied; Lausten-Thomsen, Ulrik; Pierre, Florence; Ben Laiba, Maher; Le Saché, Nolwenn; Tissieres, Pierre

    2017-01-01

    The correct choice of intra vascular access in critically ill neonates should be individualized depending on the type and duration of therapy, gestational and chronological age, weight and/or size, diagnosis, clinical status, and venous system patency. Accordingly, there is an ongoing demand for optimization of catheterization. Recently, the use of ultrasound (US)-guided cannulation of the subclavian vein (SCV) has been described in children and neonates. This article gives an overview of the current use of US for achieving central venous catheter placement in the SCV or the brachiocephalic vein (BCV) in neonates. More than 1,250 catheters have been reported inserted in children and neonates for a cumulated success rate of 98.4% and the complication rate is reported to be low. The technical aspects of various approaches are discussed, and we offer our recommendation of an US-guided technique for SCV and BCV cannulation based on our experience in a large NICU setting. Although the cannulation the SCV or BCV does not substitute the use of peripherally inserted central catheters or umbilical venous central catheters in neonates, it is a feasible route in very small children who are in need of a large caliber central venous access. PMID:29051889

  6. Stroke Volume Variation-Guided Versus Central Venous Pressure-Guided Low Central Venous Pressure With Milrinone During Living Donor Hepatectomy: A Randomized Double-Blinded Clinical Trial.

    PubMed

    Lee, Jiwon; Kim, Won Ho; Ryu, Ho-Geol; Lee, Hyung-Chul; Chung, Eun-Jin; Yang, Seong-Mi; Jung, Chul-Woo

    2017-08-01

    We previously demonstrated the usefulness of milrinone for living donor hepatectomy. However, a less-invasive alternative to central venous catheterization and perioperative contributors to good surgical outcomes remain undetermined. The current study evaluated whether the stroke volume variation (SVV)-guided method can substitute central venous catheterization during milrinone-induced profound vasodilation. We randomly assigned 42 living liver donors to receive either SVV guidance or central venous pressure (CVP) guidance to obtain milrinone-induced low CVP. Target SVV of 9% was used as a substitute for CVP of 5 mm Hg. The surgical field grade evaluated by 2 attending surgeons on a 4-point scale was compared between the CVP- and SVV-guided groups (n = 19, total number of scores = 38 per group) as a primary outcome variable. Multivariable analysis was performed to identify independent factors associated with the best surgical field as a post hoc analysis. Surgical field grades, which were either 1 or 2, were not found to be different between the 2 groups via Mann-Whitney U test (P = .358). There was a very weak correlation between SVV and CVP during profound vasodilation such as CVP ≤ 5 mm Hg (R = -0.06; 95% confidence interval, -0.09 to -0.04; P < .001). Additional post hoc analysis suggested that younger age, lower baseline CVP, and longer duration of milrinone infusion might be helpful in providing the best surgical field. Milrinone-induced vasodilation resulted in favorable surgical environment regardless of guidance methods of low CVP during living donor hepatectomy. However, SVV was not a useful indicator of low CVP because of very weak correlation between SVV and CVP during profound vasodilation. In addition, factors contributing to the best surgical field such as donor age, proactive fasting, and proper dosing of milrinone need to be investigated further, ideally through prospective studies.

  7. A survey of the use of ultrasound guidance in internal jugular venous cannulation.

    PubMed

    McGrattan, T; Duffty, J; Green, J S; O'Donnell, N

    2008-11-01

    It has been that suggested the use of two dimensional (2D) ultrasound to facilitate placement of central venous cannulae in the internal jugular vein improves patient safety and reduces complications. Since the introduction of the National Institute for Clinical Excellence Technology Appraisal Guideline Number 49 in 2002, promoting the use of ultrasound in placement of internal jugular venous cannulae, utilisation of ultrasound has increased throughout the United Kingdom. We report the findings of a postal survey of 2000 senior anaesthetists in the United Kingdom which enquired about their use of ultrasound for internal jugular vein cannulae placement. Only 27% use 2D ultrasound as their first choice technique, although 35% use it as their first choice when teaching. There was no significant difference in practice between those working within a sub specialty in anaesthesia. There continues to be discrepancies between the application of the guideline and how senior anaesthetists both site and teach the placement of internal jugular vein central venous cannulae.

  8. Quality of Widely Available Video Instructional Materials for Point-of-Care Ultrasound-Guided Procedure Training in Internal Medicine.

    PubMed

    Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek

    2017-07-01

    Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.

  9. Duplex imaging of residual venous obstruction to guide duration of therapy for lower extremity deep venous thrombosis.

    PubMed

    Stephenson, Elliot J P; Liem, Timothy K

    2015-07-01

    Clinical trials have shown that the presence of ultrasound-identified residual venous obstruction (RVO) on follow-up scanning may be associated with an elevated risk for recurrence, thus providing a potential tool to help determine the optimal duration of anticoagulant therapy. We performed a systematic review to evaluate the clinical utility of post-treatment duplex imaging in predicting venous thromboembolism (VTE) recurrence and in adjusting duration of anticoagulation. The Ovid MEDLINE Database, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Database of Abstracts of Reviews of Effects were queried for the terms residual thrombus or obstruction, duration of therapy, deep vein thrombosis, deep venous thrombosis, DVT, venous thromboembolism, VTE, antithrombotic therapy, and anticoagulation, and 228 studies were selected for review. Six studies determined the rate of VTE recurrence on the basis of the presence or absence of RVO. Findings on venous ultrasound scans frequently remained abnormal in 38% to 80% of patients, despite at least 3 months of therapeutic anticoagulation. In evaluating for VTE recurrence, the definition of RVO varied widely in the literature. Some studies have shown an association between RVO and VTE recurrence, whereas other studies have not. Overall, the presence of RVO is a mild risk factor for recurrence (odds ratio, 1.3-2.0), but only when surveillance imaging is performed soon after the index deep venous thrombosis (3 months). RVO is a mild risk factor for VTE recurrence. The presence or absence of ultrasound-identified RVO has a limited role in guiding the duration of therapeutic anticoagulation. Further research is needed to evaluate its utility relative to other known risk factors for VTE recurrence. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe

    PubMed Central

    Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.

    2014-01-01

    Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628

  11. Comparison of Ultrasonography-Guided Central Venous Catheterization Between Adult and Pediatric Populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tercan, Fahri; Oguzkurt, Levent; Ozkan, Ugur

    2008-05-15

    The purpose of this study was to compare the technical success and complication rates of ultrasonography-guided central venous catheterization between adult and pediatric patients which have not been reported previously. In a 4-year period, 859 ultrasonography-guided central vein catheterizations in 688 adult patients and 247 catheterizations in 156 pediatric patients were retrospectively evaluated. Mean age was 56.3 years (range, 18 to 95 years) for adults and 3.3 years (range, 0.1 to 16.3 years) for children. The preferred catheterization site was internal jugular vein in 97% of adults and 85% of children. The technical success rate, mean number of punctures, andmore » rate of single wall puncture were 99.4%, 1.04 (range, 1-3), and 83% for adults and 90.3%, 1.25 (range, 1-5), and 49% for children, respectively. All the differences were statistically significant (p < 0.05). Complication rates were 2.3% and 2.4% for adults and children, respectively (p > 0.05). Major complications such as pneumothorax and hemothorax were not seen in any group. In conclusion, ultrasonography-guided central venous catheterization has a high technical success rate, lower puncture attempt rate, and higher single wall puncture rate in adults compared to children. Complication rates are comparable in the two groups.« less

  12. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less

  13. Photoplethysmographic venous refilling times following ultrasound guided foam sclerotherapy for symptomatic superficial venous reflux: relationship with clinical outcomes.

    PubMed

    Darvall, K A L; Sam, R C; Bate, G R; Adam, D J; Silverman, S H; Bradbury, A W

    2010-08-01

    Digital photoplethysmography (PPG) provides an inexpensive, reproducible, quantitative, non-invasive assessment of lower limb venous function. To examine the relationship between venous refilling time (VRT) and severity of venous disease, and also between changes in VRT and symptomatic improvement after ultrasound guided foam sclerotherapy (UGFS) for symptomatic superficial venous reflux (SVR). Prior to and 6 months after UGFS, 246 patients (317 limbs) completed a symptom questionnaire, underwent duplex ultrasonography and clinical assessment, and VRT measurement by digital PPG. Health related quality of life (HRQL) questionnaires were also completed. Median VRT improved from 11 to 31 s (P < 0.0005, Wilcoxon Signed Ranks). Abnormal VRT (<20 s) correlated well with the presence of SVR on duplex (sensitivity 75%, specificity 94%). Pre-treatment there was a significant relationship between reducing VRT and increasing CEAP clinical grade (P < 0.0005, chi(2)), extent of SVR on duplex (P < 0.0005) and a non-significant relationship with overall increasing symptom severity (P = 0.097). Relief of all symptoms was more likely when there was normalisation of VRT after treatment (80% vs. 65%, P < 0.0005, chi(2)). Pre-treatment VRT correlated with both generic physical (r = 0.428, P = 0.002) and disease-specific (r = -0.413, P = 0.003, Spearman's rank) HRQL. UGFS for SVR improves VRT measured by digital PPG and that improvement correlates with symptom relief. Copyright (c) 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakamoto, Noriaki, E-mail: nosakamoto@hotmail.co.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp; Takeuchi, Yoshito, E-mail: yostakeu@ncc.go.jp

    2010-10-15

    The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurredmore » in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.« less

  15. Ultrasound confirmation of central venous catheter position via a right supraclavicular fossa view using a microconvex probe: an observational pilot study.

    PubMed

    Kim, Se-Chan; Heinze, Ingo; Schmiedel, Alexandra; Baumgarten, Georg; Knuefermann, Pascal; Hoeft, Andreas; Weber, Stefan

    2015-01-01

    Visualisation of a central venous catheter (CVC) with ultrasound is restricted to the internal jugular vein (IJV). CVC tip position is confirmed by chest radiography, intracardiac ECG or transoesophageal/transthoracic echocardiography (TEE/TTE). We explored the feasibility, safety and accuracy of a right supraclavicular view for visualisation of the lower superior vena cava (SVC) and the right pulmonary artery (RPA) as an ultrasound landmark for real-time ultrasound-guided CVC tip positioning via the right IJV. Ultrasound was then compared with chest radiography. An observational pilot study. Bonn, University Hospital, Germany. From July to October 2012. Fifty-one patients scheduled for elective surgery. Reasons for exclusion were emergency procedure, thrombosis or small IJV lumen and mechanical obstacle to guidewire advancement. In 48 patients, CVC insertion via the right IJV and progress of the guidewire into the lower SVC were continuously guided by an ultrasound transducer in the right supraclavicular fossa. CVC tip position in lower SVC and tip-to-carina distance were assessed with chest radiography as a reference method and additionally with TEE in cardiothoracic patients. Insertion depth was compared with intracardiac ECG and body-height formula. The guidewire tip was seen in the SVC of all patients. In four patients, the tip was not visible in proximity of the RPA. Chest radiography and TEE confirmed CVC tip position in the lower SVC (zone A). Bland-Altman analysis revealed an average of difference of 1.6 cm for ultrasound versus ECG (95% limit of agreement -2 to 5 cm) and an average of difference of 1 cm for ultrasound versus body-height formula (95% limit of agreement -2 to 4 cm). Ultrasound via a right supraclavicular view is a feasible, well tolerated and accurate approach and should be further explored. Chest radiography confirmed CVC position in the lower SVC.

  16. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients

    PubMed Central

    Karakitsos, Dimitrios; Labropoulos, Nicolaos; De Groot, Eric; Patrianakos, Alexandros P; Kouraklis, Gregorios; Poularas, John; Samonis, George; Tsoutsos, Dimosthenis A; Konstadoulakis, Manousos M; Karabinis, Andreas

    2006-01-01

    Introduction Central venous cannulation is crucial in the management of the critical care patient. This study was designed to evaluate whether real-time ultrasound-guided cannulation of the internal jugular vein is superior to the standard landmark method. Methods In this randomised study, 450 critical care patients who underwent real-time ultrasound-guided cannulation of the internal jugular vein were prospectively compared with 450 critical care patients in whom the landmark technique was used. Randomisation was performed by means of a computer-generated random-numbers table, and patients were stratified with regard to age, gender, and body mass index. Results There were no significant differences in gender, age, body mass index, or side of cannulation (left or right) or in the presence of risk factors for difficult venous cannulation such as prior catheterisation, limited sites for access attempts, previous difficulties during catheterisation, previous mechanical complication, known vascular abnormality, untreated coagulopathy, skeletal deformity, and cannulation during cardiac arrest between the two groups of patients. Furthermore, the physicians who performed the procedures had comparable experience in the placement of central venous catheters (p = non-significant). Cannulation of the internal jugular vein was achieved in all patients by using ultrasound and in 425 of the patients (94.4%) by using the landmark technique (p < 0.001). Average access time (skin to vein) and number of attempts were significantly reduced in the ultrasound group of patients compared with the landmark group (p < 0.001). In the landmark group, puncture of the carotid artery occurred in 10.6% of patients, haematoma in 8.4%, haemothorax in 1.7%, pneumothorax in 2.4%, and central venous catheter-associated blood stream infection in 16%, which were all significantly increased compared with the ultrasound group (p < 0.001). Conclusion The present data suggest that ultrasound-guided

  17. Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?

    PubMed

    Yıldırım, İlknur; Tütüncü, Ayşe Çiğdem; Bademler, Süleyman; Özgür, İlker; Demiray, Mukaddes; Karanlık, Hasan

    2018-03-01

    To examine whether the real-time ultrasound-guided venipuncture for implantable venous port placement is safer than the traditional venipuncture. The study analyzed the results of 2153 venous ports placed consecutively from January 2009 to January 2016. A total of 922 patients in group 1 and 1231 patients in group 2 were admitted with venous port placed using the traditional landmark subclavian approach and real-time ultrasound-guided axillary approach, respectively. Sociodemographic characteristics of patients, early (pneumothorax, pinch-off syndrome, arterial puncture, hematoma, and malposition arrhythmia) and late (deep vein thrombosis, obstruction, infection, erosion-dehiscence, and rotation of the port chamber) complications and the association of these complications with the implantation method were evaluated. There were no significant differences in the sociodemographic characteristics of the patients between the two groups. The overall and early complications in group 2 were significantly lower than those in group 1. Pinch-off syndrome only developed in group 1. Seven patients and two patients had pneumothorax in groups 1 and 2, respectively. Puncture number was significantly associated with the development of the overall complications. The ultrasound-guided axillary approach may be preferred as a method to reduce the risk of both early and late complications. Large, randomized, controlled prospective trials will be helpful in determining a safer implantable venous port implantation technique.

  18. Sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region

    PubMed Central

    Karmakar, M K; Li, X; Kwok, W H; Ho, A M-H; Ngan Kee, W D

    2012-01-01

    Objectives The use of ultrasound to guide peripheral nerve blocks is now a well-established technique in regional anaesthesia. However, despite reports of ultrasound guided epidural access via the paramedian approach, there are limited data on the use of ultrasound for central neuraxial blocks, which may be due to a poor understanding of spinal sonoanatomy. The aim of this study was to define the sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach. Methods The sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach was defined using a “water-based spine phantom”, young volunteers and anatomical slices rendered from the Visible Human Project data set. Results The water-based spine phantom was a simple model to study the sonoanatomy of the osseous elements of the lumbar spine. Each osseous element of the lumbar spine, in the spine phantom, produced a “signature pattern” on the paramedian sagittal scans, which was comparable to its sonographic appearance in vivo. In the volunteers, despite the narrow acoustic window, the ultrasound visibility of the neuraxial structures at the L3/L4 and L4/L5 lumbar intervertebral spaces was good, and we were able to delineate the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach. Conclusion Using a simple water-based spine phantom, volunteer scans and anatomical slices from the Visible Human Project (cadaver) we have described the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region. PMID:22010025

  19. Influence of arm position on catheter placement during real-time ultrasound-guided right infraclavicular proximal axillary venous catheterization.

    PubMed

    Ahn, J H; Kim, I S; Shin, K M; Kang, S S; Hong, S J; Park, J H; Kim, H J; Lee, S H; Kim, D Y; Jung, J H

    2016-03-01

    Real-time ultrasound-guided infraclavicular proximal axillary venous catheterization is used in many clinical situations and provides the advantages of catheter stabilization, a reduced risk of catheter-related infection, and comfort for the patient without limitation of movement. However, unintended catheter tip dislocation and accidental arterial puncture occur occasionally. This study was designed to investigate the influence of arm position on catheter placement and complications. Patients were randomized to either the neutral group (n=240) or the abduction group (n=241). In the neutral group, patients were positioned with the head and shoulders placed in an anatomically neutral position and the arms kept by the side during catheterization. In the abduction group, the right upper arm was abducted at 90° from the trunk during catheterization. After real-time ultrasound-guided catheterization was carried out in the right infraclavicular proximal axillary vein, misplacement of the catheter and all complications were evaluated with ultrasound and chest radiography. The success rate of complete catheterization before evaluating the placement of the catheter was high in both groups (97.1 vs 98.8%, P=not significant). The incidence of accidental arterial puncture was not different (1.7 vs 0%, P=not significant). The incidence of misplacement of the catheter was higher in the neutral group than in the abduction group (3.9 vs 0.4%, P=0.01). There were no complications, such as haemothorax, pneumothorax, or injury to the brachial plexus and phrenic nerve, in either group. Upper arm abduction may minimize the risk of misplacement of the catheter during real-time ultrasound-guided infraclavicular proximal axillary venous catheterization. The trial was registered with the Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp. Identifier: KCT0001417. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia

  20. Venous catheterization with ultrasound navigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasatkin, A. A., E-mail: ant-kasatkin@yandex.ru; Nigmatullina, A. R.; Urakov, A. L., E-mail: ant-kasatkin@yandex.ru

    By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization.more » We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient’s exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.« less

  1. Venous catheterization with ultrasound navigation

    NASA Astrophysics Data System (ADS)

    Kasatkin, A. A.; Urakov, A. L.; Nigmatullina, A. R.

    2015-11-01

    By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization. We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient's exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.

  2. Central venous catheters: incidence and predictive factors of venous thrombosis.

    PubMed

    Hammes, Mary; Desai, Amishi; Pasupneti, Shravani; Kress, John; Funaki, Brian; Watson, Sydeaka; Herlitz, Jean; Hines, Jane

    2015-07-01

    Central venous catheter access in an acute setting can be a challenge given underlying disease and risk for venous thrombosis. Peripherally inserted central venous catheters (PICCs) are commonly placed but limit sites for fistula creation in patients with chronic renal failure (CKD). The aim of this study is to determine the incidence of venous thrombosis from small bore internal jugular (SBIJ) and PICC line placement. This investigation identifies populations of patients who may not be ideal candidates for a PICC and highlights the importance of peripheral vein preservation in patients with renal failure. A venous Doppler ultrasound was performed at the time of SBIJ insertion and removal to evaluate for thrombosis in the internal jugular vein. Data was collected pre- and post-intervention to ascertain if increased vein preservation knowledge amongst the healthcare team led to less use of PICCs. Demographic factors were collected in the SBIJ and PICC groups and risk factor analysis was completed. 1,122 subjects had PICC placement and 23 had SBIJ placement. The incidence of thrombosis in the PICC group was 10%. One patient with an SBIJ had evidence of central vein thrombosis when the catheter was removed. Univariate and multivariate analysis demonstrated a history of transplant, and the indication of total parenteral nutrition was associated with thrombosis (p<0.001). The decrease in PICCs placed in patients with CKD 6 months before and after intervention was significant (p<0.05). There are subsets of patients ith high risk for thrombosis who may not be ideal candidates for a PICC.

  3. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  4. Efficacy and safety of ultrasound-guided placement of central venous port systems via the right internal jugular vein in elderly oncologic patients: our single-center experience and protocol.

    PubMed

    Canfora, Alfonso; Mauriello, Claudio; Ferronetti, Antonio; Marte, Gianpaolo; Di Maio, Vittorio; Ciorra, Guido; Esposito, Maria Grazia; Giuliano, Maria Elena; Fregola, Giovanni; Barra, Luigi; Cuzzovaglia, Salvatore; Bottino, Vincenzo; Maida, Pietro

    2017-02-01

    Ultrasound-guidance has become the routine method for internal jugular vein (IJV) catheterization reducing dramatically failure and complication rates for central venous port (CVP) placement. The aim of this study was to determine the safety and efficacy of ultrasound-guided IJV CVP placement in elderly oncologic patients. Between January 2013 and December 2015, 101 elderly oncological patients underwent right IJV CVP placement under ultrasound-guidance. The length of catheter introduction ranged from 18 to 21 cm. Intraoperative fluoroscopy (IF) was always performed intraoperatively. Chest X-ray (CXR) was always performed 30 min after the end of the procedure. The morbidity rate was 1.98%; two arterial punctures were reported with one self-limiting hematoma. Two patients (1.98%) had catheter misplacements, recognized by intraoperative IF. No patients (0%) experienced pneumothorax (PNX), confirmed at CXR. Patients were all discharged at maximum 6 h from the procedure. The risk of catheter misplacement, PNX, and arterial/nerve puncture remains present with this technique. Lower rates of catheter misplacement have been reported after right IJV puncture, probably for its straight vertical course. Our results are in accordance with literature (1 counter-lateral subclavian vein and 1 counter-lateral internal jugular vein misplacements). All misplacements were detected intraoperatively. The PNX rates after cannulation of the IJV vary between 0.0 and 0.5%. We had no PNX occurrence. Ultrasonography (US) has improved safety and effectiveness of port system placements. While routine post-procedural CXR seems avoidable, IF should be considered mandatory.

  5. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    NASA Astrophysics Data System (ADS)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  6. Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

    PubMed

    Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita

    2016-10-01

    Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.

  7. Current situation regarding central venous port implantation procedures and complications: a questionnaire-based survey of 11,693 implantations in Japan.

    PubMed

    Shiono, Masatoshi; Takahashi, Shin; Takahashi, Masanobu; Yamaguchi, Takuhiro; Ishioka, Chikashi

    2016-12-01

    We conducted a nationwide questionnaire-based survey to understand the current situation regarding central venous port implantation in order to identify the ideal procedure. Questionnaire sheets concerning the number of implantation procedures and the incidence of complications for all procedures completed in 2012 were sent to 397 nationwide designated cancer care hospitals in Japan in June 2013. Venipuncture sites were categorized as chest, neck, upper arm, forearm, and others. Methods were categorized as landmark, cut-down, ultrasound-mark, real-time ultrasound guided, venography, and other groups. We received 374 responses (11,693 procedures) from 153 centers (38.5 %). The overall complication rates were 7.4 % for the chest (598/8,097 cases); 6.8 % for the neck (157/2325); 5.2 % for the upper arm (54/1,033); 7.3 % for the forearm (9/124); and 6.1 % for the other groups (7/114). Compared to the chest group, only the upper arm group showed a significantly lower incidence of complications (P = 0.010), and multivariate logistic regression (odds ratio 0.69; 95 % confidence interval 0.51-0.91; P = 0.008) also showed similar findings. Real-time ultrasound-guided puncture was most commonly used in the upper arm group (83.8 %), followed by the neck (69.8 %), forearm (53.2 %), chest (41.8 %), and other groups (34.2 %). Upper arm venipuncture with ultrasound guidance seems the most promising technique to prevent complications of central venous port implantation.

  8. Central venous access in children: indications, devices, and risks.

    PubMed

    Ares, Guillermo; Hunter, Catherine J

    2017-06-01

    Central venous catheters (CVCs) have a prominent role in the diagnostic and therapy of neonates and children. Herein, we describe the multiple indications for CVC use and the different devices available for central venous access. Given the prevalent use of CVCs, healthcare systems are focused on reducing complications from their use, particularly central line-associated bloodstream infections (CLABSIs). The most up-to-date information available sheds light on best practices and future areas of investigation. Large systematic reviews of randomized trials suggest that ultrasound guidance for placement of CVCs in children is safer than using blind technique, at least for internal jugular vein access. Appropriate catheter tip placement is associated with decreased complications. Furthermore, the prophylactic use of ethanol lock between cycles of parenteral nutrition administration has reduced the rates of CLABSI. A recent randomized trial in pediatric CVCs showed a benefit with antibiotic-coated CVCs. Based on the available evidence, multiple techniques for CVC placement are still valid, including the landmark technique based on practitioner experience, but ultrasound guidance has been shown to decrease complications from line placement. Adherence to CVC care protocols is essential in reducing infectious complications.

  9. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    PubMed

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  10. Creating and evaluating a data-driven curriculum for central venous catheter placement.

    PubMed

    Duncan, James R; Henderson, Katherine; Street, Mandie; Richmond, Amy; Klingensmith, Mary; Beta, Elio; Vannucci, Andrea; Murray, David

    2010-09-01

    Central venous catheter placement is a common procedure with a high incidence of error. Other fields requiring high reliability have used Failure Mode and Effects Analysis (FMEA) to prioritize quality and safety improvement efforts. To use FMEA in the development of a formal, standardized curriculum for central venous catheter training. We surveyed interns regarding their prior experience with central venous catheter placement. A multidisciplinary team used FMEA to identify high-priority failure modes and to develop online and hands-on training modules to decrease the frequency, diminish the severity, and improve the early detection of these failure modes. We required new interns to complete the modules and tracked their progress using multiple assessments. Survey results showed new interns had little prior experience with central venous catheter placement. Using FMEA, we created a curriculum that focused on planning and execution skills and identified 3 priority topics: (1) retained guidewires, which led to training on handling catheters and guidewires; (2) improved needle access, which prompted the development of an ultrasound training module; and (3) catheter-associated bloodstream infections, which were addressed through training on maximum sterile barriers. Each module included assessments that measured progress toward recognition and avoidance of common failure modes. Since introducing this curriculum, the number of retained guidewires has fallen more than 4-fold. Rates of catheter-associated infections have not yet declined, and it will take time before ultrasound training will have a measurable effect. The FMEA provided a process for curriculum development. Precise definitions of failure modes for retained guidewires facilitated development of a curriculum that contributed to a dramatic decrease in the frequency of this complication. Although infections and access complications have not yet declined, failure mode identification, curriculum development, and

  11. Ultrasound guidance for central venous catheter placement in Australasian emergency departments: potential barriers to more widespread use.

    PubMed

    Matera, Jakub T; Egerton-Warburton, Diana; Meek, Robert

    2010-12-01

    To survey Fellows of the Australasian College for Emergency Medicine (FACEMs) in order to describe current ultrasound (US) usage during central venous catheter (CVC) placement and to compare practice and opinions between FACEMs routinely using US and those not. Descriptive and analytical cross-sectional electronic survey of all FACEMs. Baseline variables including hospital type, US availability, frequency of CVC insertion, US usage and technique are presented descriptively. US practice and opinions on usage are compared between routine and non-routine users. Responses were obtained from 486 (42.4%) of 1146 FACEMs emailed. Whereas 88.5% of respondents had US available and 70% had done an US course, only 37% routinely used US for CVC placement. Completion of an US course and performance of >11 CVC per year were strongly associated with routine US use (odds ratio 10.0 [5.5-18.4] and 2.6 [1.7-3.9], respectively). Common barriers to more frequent US use were not having completed an US course (20%) and US-guided CVC placement taking too long (18%). Eighty-five per cent of FACEMs agreed that there should be ED access to US and US training but only 34% thought its use should be mandatory. We found that only 37% of FACEM respondents routinely used US to guide placement of CVCs and a number of barriers to more frequent use are identified. Practices and opinions regarding US use differed significantly between routine and non-routine users. © 2010 The Authors. EMA © 2010 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  12. Validation of a novel venous duplex ultrasound objective structured assessment of technical skills for the assessment of venous reflux.

    PubMed

    Jaffer, Usman; Normahani, Pasha; Lackenby, Kimberly; Aslam, Mohammed; Standfield, Nigel J

    2015-01-01

    Duplex ultrasound measurement of reflux time is central to the diagnosis of venous incompetence. We have developed an assessment tool for Duplex measurement of venous reflux for both simulator and patient-based training. A novel assessment tool, Venous Duplex Ultrasound Assessment of Technical Skills (V-DUOSATS), was developed. A modified DUOSATS was used for simulator training. Participants of varying skill level were invited to viewed an instructional video and were allowed ample time to familiarize with the Duplex equipment. Attempts made by the participants were recorded and independently assessed by 3 expert assessors and 5 novice assessors using the modified V-DUOSATS. "Global" assessment was also done by expert assessors on a 4-point Likert scale. Content, construct, and concurrent validities as well as reliability were evaluated. Content and construct validity as well as reliability were demonstrated. Receiver operator characteristic analysis-established cut points of 19/22 and 21/30 were most appropriate for simulator and patient-based assessment, respectively. We have validated a novel assessment tool for Duplex venous reflux measurement. Further work is required to establish transference validity of simulator training to improve skill in scanning patients. We have developed and validated V-DUOSATS for simulator training. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  13. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    PubMed

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  14. Risk factors for venous thrombosis associated with peripherally inserted central venous catheters

    PubMed Central

    Pan, Longfang; Zhao, Qianru; Yang, Xiangmei

    2014-01-01

    To evaluate the risk factors associated with an increased risk of symptomatic peripherally inserted central venous catheter (PICC)-related venous thrombosis. Retrospective analyses identified 2313 patients who received PICCs from 1 January 2012 to 31 December 2013. All 11 patients with symptomatic PICC-related venous thrombosis (thrombosis group) and 148 who did not have thromboses (non-thrombosis group) were selected randomly. The medical information of 159 patients (age, body mass index (BMI), diagnosis, smoking history, nutritional risk score, platelet count, leucocyte count as well as levels of D-dimer, fibrinogen, and degradation products of fibrin) were collected. Logistic regression analysis was undertaken to determine the risk factors for thrombosis. Of 2313 patients, 11 (0.47%) were found to have symptomatic PICC-related venous thrombosis by color Doppler ultrasound. Being bedridden for a long time (odds ratio [(OR]), 17.774; P=0.0017), D-dimer >5 mg/L (36.651; 0.0025) and suffering from one comorbidity (8.39; 0.0265) or more comorbidities (13.705; 0.0083) were the major risk factors for PICC-catheter related venous thrombosis by stepwise logistic regression analysis. Among 159 patients, the prevalence of PICC-associated venous thrombosis in those with ≥1 risk factor was 10.34% (12/116), in those with ≥2 risk factors was 20.41% (10/49), and in those with >3 risk factors was 26.67% (4/15). Being bedridden >72 h, having increased levels of D-dimer (>5 mg/L) and suffering from comorbidities were independent risk factors of PICC-related venous thrombosis. PMID:25664112

  15. Internal Medicine Point-of-Care Ultrasound Curriculum: Consensus Recommendations from the Canadian Internal Medicine Ultrasound (CIMUS) Group.

    PubMed

    Ma, Irene W Y; Arishenkoff, Shane; Wiseman, Jeffrey; Desy, Janeve; Ailon, Jonathan; Martin, Leslie; Otremba, Mirek; Halman, Samantha; Willemot, Patrick; Blouw, Marcus

    2017-09-01

    Bedside point-of-care ultrasound (POCUS) is increasingly used to assess medical patients. At present, no consensus exists for what POCUS curriculum is appropriate for internal medicine residency training programs. This document details the consensus-based recommendations by the Canadian Internal Medicine Ultrasound (CIMUS) group, comprising 39 members, representing 14 institutions across Canada. Guiding principles for selecting curricular content were determined a priori. Consensus was defined as agreement by at least 80% of the members on POCUS applications deemed appropriate for teaching and assessment of trainees in the core (internal medicine postgraduate years [PGY] 1-3) and expanded (general internal medicine PGY 4-5) training programs. We recommend four POCUS applications for the core PGY 1-3 curriculum (inferior vena cava, lung B lines, pleural effusion, and abdominal free fluid) and three ultrasound-guided procedures (central venous catheterization, thoracentesis, and paracentesis). For the expanded PGY 4-5 curriculum, we recommend an additional seven applications (internal jugular vein, lung consolidation, pneumothorax, knee effusion, gross left ventricular systolic function, pericardial effusion, and right ventricular strain) and four ultrasound-guided procedures (knee arthrocentesis, arterial line insertion, arterial blood gas sampling, and peripheral venous catheterization). These recommendations will provide a framework for training programs at a national level.

  16. Ultrasonography-guided central venous catheterisation in haematological patients with severe thrombocytopenia

    PubMed Central

    Napolitano, Mariasanta; Malato, Alessandra; Raffaele, Francesco; Palazzolo, Manuela; Iacono, Giorgio Lo; Pinna, Roberto; Geraci, Girolamo; Modica, Giuseppe; Saccullo, Giorgia; Siragusa, Sergio; Cajozzo, Massimo

    2013-01-01

    Background Cannulation of the internal jugular vein (CVC) is a blind surface landmark-guided technique that could be potentially dangerous in patients with very low platelet counts. In such patients, ultrasonography (US)-guided CVC may be a valid approach. There is a lack of published data on the efficacy and safety of urgent US-guided CVC performed in haematological patients with severe thrombocytopenia. Materials and methods We retrospectively studied the safety of urgent CVC procedures in haematological patients including those with severe thrombocytopenia (platelet count <30×109/L). From January 1999 to June 2009, 431 CVC insertional procedures in 431 consecutive patients were evaluated. Patients were included in the study if they had a haematological disorder and required urgent CVC insertion. Patients were placed in Trendelenburg's position, an 18-gauge needle and guide-wire were advanced under real-time US guidance into the last part of the internal jugular vein; central venous cannulation of the internal jugular vein was performed using the Seldinger technique in all the procedures. Major and minor procedure-related complications were recorded. Results All 431 patients studied had haematological disorders: 39 had severe thrombocytopenia, refractory to platelet transfusion (group 1), while 392 did not have severe thrombocytopenia (group 2). The general characteristics of the patients in the two groups differed only for platelet count. The average time taken to perform the procedure was 4 minutes. Success rates were 97.4% and 97.9% in group 1 and group 2, respectively. No major complications occurred in either group. Discussion US-guided CVC is a safe and effective approach in haematological patients with severe thrombocytopenia requiring urgent cannulation for life support, plasma-exchange, chemotherapy and transfusion. PMID:23399356

  17. DKA, CVL and DVT. Increased risk of deep venous thrombosis in children with diabetic ketoacidosis and femoral central venous lines.

    PubMed

    Davis, J; Surendran, T; Thompson, S; Corkey, C

    2007-01-01

    Incidence of type 1 diabetes mellitus is continuing to rise in children. The presentation of diabetic ketoacidosis (DKA) in children with newly diagnosed diabetes is significantly higher in those less than 5 years old. Critically ill patients admitted to Paediatric Intensive Care Units (PICU), would have a central venous line (CVL) inserted as part of their ongoing management. There are associations linking with the development of deep venous thrombosis (DVT) in DKA/CVL patients. An 18-month-old boy presented with a short history of polydypsia, polyuria and weight loss. The initial blood sugar was 27.0 mmol/L and a venous blood gas showed severe metabolic acidosis. He was diagnosed and treated for DKA. He was transferred to the regional PICU for further management. There, a central venous line (CVL) was inserted in his left femoral vein. This was removed on Day 4. Subsequently, he developed a swelling on his left leg, with significant discrepancy in leg circumference. Doppler ultrasound confirmed a deep venous thrombosis. Conclusion Diabetes has a propensity for hypercoagulability and DKA promotes a prothrombotic state. Retrospective studies have shown younger patients with DKA and a femoral CVL are at higher risk of developing DVT. A central femoral line should avoided in such patients. DVT prophylaxis and Doppler follow up should also be considered.

  18. Venous thrombosis and stenosis after peripherally inserted central catheter placement in children.

    PubMed

    Shin, H Stella; Towbin, Alexander J; Zhang, Bin; Johnson, Neil D; Goldstein, Stuart L

    2017-11-01

    Peripherally inserted central catheters (PICCs) can lead to development of venous thrombosis and/or stenosis. The presence of venous thrombosis and/or stenosis may preclude children with chronic medical conditions from receiving lifesaving therapies, from hemodialysis in end-stage renal disease to total parenteral nutrition in short bowel syndrome. Several adult studies have found an association between PICCs and venous thrombosis and/or stenosis, but none has evaluated for this association in children. To determine the incidence of venous thrombosis and/or stenosis after PICC placement and identify factors that increase the risk of venous thrombosis and/or stenosis after PICC placement in children. We conducted a retrospective review of children ages 1-18 years with a PICC placed between January 2010 and July 2013 at our center, and included those who had at least one vascular imaging study of the ipsilateral extremity (Doppler ultrasound, venogram or MR angiogram) after PICC placement. Logistic regression was applied to determine risk factors for development of venous thrombosis and/or stenosis. One thousand, one hundred and ten upper extremity PICCs were placed, with 703 PICCs in the right and 407 PICCs in the left. Eight hundred fifty-one imaging studies (609 Doppler ultrasounds, 193 contrast venograms and 49 MR angiograms) were performed in 376 patients. The incidence of venous thrombosis and/or stenosis in the imaged cohort was 26.3%. PICC laterality, insertion site, duration, patient height to PICC diameter ratio, and number of PICCs per patient were not associated with development of venous thrombosis and/or stenosis. Additionally, primary diagnosis and symptoms at the time of imaging did not predict findings of venous thrombosis and/or stenosis. However, patients exposed to non-PICC central venous catheters (CVC) were more likely to develop venous thrombosis and/or stenosis (odds ratio 1.95, 1.10-3.45). More than a quarter of the vascular imaging studies

  19. Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

    PubMed

    Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos

    2017-02-27

    Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly

  20. Significance of Blunted Venous Waveforms Seen on Upper Extremity Ultrasound.

    PubMed

    Pham, Xuan-Binh D; Ihenachor, Ezinne J; Wu, Hoover; Kim, Jerry J; Kaji, Amy H; Koopmann, Matthew C; Ryan, Timothy J; de Virgilio, Christian

    2017-07-01

    Current guidelines recommend vascular mapping ultrasound (US) prior to arteriovenous fistula creation. Blunted venous waveforms (BVWs) suggest central venous stenosis; however, this relationship and one between BVWs and the presence of a central venous catheter (CVC) remain unclear. All patients who received upper extremity vascular mapping US between January 2013 and October 2014 at a single institution were retrospectively reviewed. Patient demographics, comorbidities, US results, pacemaker history, and CVC status were collected. Waveforms were assessed at the proximal subclavian vein/distal axillary vein and interpreted by radiologists. Patients were determined to have central venous stenosis (CVS) if detected by venography within 6 months of US. There were 342 patients, of which 165 (48%) had a current CVC and 29 (8.5%) had BVW of at least 1 arm. Right-sided BVW were associated with a history of a prior ipsilateral CVC (odds ratio [OR] = 4.5, 95% confidence interval [CI] = 1.6-12.6, P = 0.009). Of the 342 patients, 69 (20%) had a venogram within 6 months. Seventeen (25%) of the 69 patients had CVS, with 7 involving the left subclavian vein, 8 the right subclavian vein, and 3 the superior vena cava (one patient had tandem stenoses). A BVW on the left side was not associated with any CVS. A BVW on the right side was associated with an ipsilateral CVS (OR = 5.8, 95% CI = 1.2-27.4, P = 0.04). This association persisted in the setting of a prior CVC (relative risk = 1.3, 95% CI = 0.9-2, P = 0.01). There are associations between right-sided BVW and an ipsilateral subclavian vein stenosis. We recommend that hemodialysis access planning includes venography to rule out central vein stenosis in patients with BVW, especially if right-sided and in the setting of a prior CVC. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Hydrothorax after Central Venous Catheterization

    PubMed Central

    Rudge, C. J.; Bewick, M.; McColl, I.

    1973-01-01

    Three patients are described who developed hydrothorax as a complication of central venous catheterization. Respiratory distress associated with physical signs of fluid in the chest should arouse suspicion that the venous catheter has perforated the wall of the vein. The complications of central venous catheterization are reviewed and three cases of hydrothorax are presented. Comments on the prevention of these complications, their diagnosis and treatment if they occur, are made. ImagesFIG. 1FIG. 2 PMID:4717421

  2. Human cerebral venous outflow pathway depends on posture and central venous pressure

    PubMed Central

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  3. Ultrasound guidance for internal jugular vein cannulation: Continuing Professional Development.

    PubMed

    Ayoub, Christian; Lavallée, Catherine; Denault, André

    2010-05-01

    The objective of this continuing professional development module is to describe the role of ultrasound for central venous catheterization and to specify its benefits and limitations. Although ultrasound techniques are useful for all central venous access sites, the focus of this module is on the internal jugular vein approach. In recent years, several studies were published on the benefits of ultrasound use for central venous catheterization. This technique has evolved rapidly due to improvements in the equipment and technology available. Ultrasound helps to detect the anatomical variants of the internal jugular vein. The typical anterolateral position of the internal jugular vein with respect to the carotid is found in only 9-92% of cases. Ultrasound guidance reduces the rate of mechanical, infectious, and thrombotic complications by 57%, and it also reduces the failure rate by 86%. Cost-benefit analyses show that the cost of ultrasound equipment is compensated by the decrease in the expenses associated with the treatment of complications. In this article, we will review the history of ultrasound guidance as well as the reasons that account for its superiority over the classical anatomical landmark technique. We will describe the equipment needed for central venous catheterization as well as the various methods to visualize with ultrasound. To improve patient safety, we recommend the use of ultrasound for central venous catheterization using the internal jugular approach.

  4. Prevention of Contrast-Induced Nephropathy by Central Venous Pressure-Guided Fluid Administration in Chronic Kidney Disease and Congestive Heart Failure Patients.

    PubMed

    Qian, Geng; Fu, Zhenhong; Guo, Jun; Cao, Feng; Chen, Yundai

    2016-01-11

    This study aimed to explore the hemodynamic index-guided hydration method for patients with congestive heart failure (CHF) and chronic kidney disease (CKD) to reduce the risk of contrast-induced nephropathy (CIN) and at the same time to avoid the acute heart failure. Patients at moderate or high risk for CIN should receive sufficient hydration before contrast application. This prospective, randomized, double-blind, comparative clinical trial enrolled 264 consecutive patients with CKD and CHF undergoing coronary procedures. These patients were randomly assigned to either central venous pressure (CVP)-guided hydration group (n = 132) or the standard hydration group (n = 132). In the CVP-guided group, the hydration infusion rate was dynamically adjusted according to CVP level every hour. CIN was defined as an absolute increase in serum creatinine (SCr) >0.5 mg/dl (44.2 μmol/l) or a relative increase >25% compared with baseline SCr. Baseline characteristics were well-matched between the 2 groups. The total mean volume of isotonic saline administered in the CVP-guided hydration group was significantly higher than the control group (1,827 ± 497 ml vs. 1,202 ± 247 ml; p < 0.001). CIN occurred less frequently in CVP-guided hydration group than the control group (15.9% vs. 29.5%; p = 0.006). The incidences of acute heart failure during the hydration did not differ between the 2 groups (3.8% vs. 3.0%; p = 0.500). CVP-guided fluid administration can safely and effectively reduce the risk of CIN in patients with CKD and CHF. (Central Venous Pressure Guided Hydration Prevention for Contrast-Induced Nephropathy; NCT02405377). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Hemodynamic and clinical impact of ultrasound-derived venous reflux parameters.

    PubMed

    Neglén, Peter; Egger, John F; Olivier, Jake; Raju, Seshadri

    2004-08-01

    This study was undertaken to assess which ultrasound-derived parameter was superior for measuring venous reflux quantitatively and to evaluate the importance of popliteal vein valve reflux. A retrospective analysis was performed of 244 refluxive limbs in 182 patients who underwent ultrasound scanning, venous pressure measurement, air plethysmography, and clinical classification of severity according to the CEAP score. Reflux time (RT, s), peak reflux velocity (PRV, m/s), time of average rate of reflux (TAF, mL/min), absolute displaced volume retrogradely (ADV, mL) were compared to clinical class, ambulatory venous pressure (% drop), venous filling time (s), and venous filling index (mL/s) using nonparametric statistical tests. A P value of <.05 was considered significant. Limbs were divided into 3 groups: (A) axial great saphenous vein reflux only (n = 68); (B) axial deep reflux including popliteal vein incompetence with or without concomitant gastrocnemius or great or small saphenous vein reflux (all ultrasound reflux parameters of each refluxive vein added at the knee level) (n = 79); and (C) all limbs with popliteal vein reflux (the ultrasound data of the refluxive popliteal vein exclusively was used in comparison regardless of concomitant associated reflux) (n = 103). Limbs were also stratified into limbs with skin changes and ulcer (C-class 4-6) and those without (C-class 1-3) and subsequently compared. No meaningful significant correlation was found between RT and the clinical and hemodynamic results in groups A and B. The PRV and TAF correlated significantly with the hemodynamic parameters. The PRV and TAF and clinical severity trended towards correlation in group A (P =.0554 and P =.0998, respectively), but was significantly correlated in group B. The poor hemodynamic condition in the subset of C-class 4-6 limbs in groups A and B was reflected in a greater PRV, TAF, and ADV in this subset as compared with the limbs in C-class 1-3. RT was not significantly

  6. Changing concepts in long-term central venous access: catheter selection and cost savings.

    PubMed

    Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A

    2001-02-01

    Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted

  7. Ultrasound-guided chest biopsies.

    PubMed

    Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar

    2006-12-01

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.

  8. Development of Needle Insertion Manipulator for Central Venous Catheterization

    NASA Astrophysics Data System (ADS)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  9. [Injuries to blood vessels near the heart caused by central venous catheters].

    PubMed

    Abram, J; Klocker, J; Innerhofer-Pompernigg, N; Mittermayr, M; Freund, M C; Gravenstein, N; Wenzel, V

    2016-11-01

    Injuries to blood vessels near the heart can quickly become life-threatening and include arterial injuries during central venous puncture, which can lead to hemorrhagic shock. We report 6 patients in whom injury to the subclavian artery and vein led to life-threatening complications. Central venous catheters are associated with a multitude of risks, such as venous thrombosis, air embolism, systemic or local infections, paresthesia, hemothorax, pneumothorax, and cervical hematoma, which are not always immediately discernible. The subclavian catheter is at a somewhat lower risk of catheter-associated sepsis and symptomatic venous thrombosis than approaches via the internal jugular and femoral veins. Indeed, access via the subclavian vein carries a substantial risk of pneumo- and hemothorax. Damage to the subclavian vein or artery can also occur during deliberate and inadvertent punctures and result in life-threatening complications. Therefore, careful consideration of the access route is required in relation to the patient and the clinical situation, to keep the incidence of complications as low as possible. For catheterization of the subclavian vein, puncture of the axillary vein in the infraclavicular fossa is a good alternative, because ultrasound imaging of the target vessel is easier than in the subclavian vein and the puncture can be performed much further from the lung.

  10. Central Venous Catheter (Central Line)

    MedlinePlus

    ... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...

  11. Implementation of a children's hospital-wide central venous catheter insertion and maintenance bundle.

    PubMed

    Helder, Onno; Kornelisse, René; van der Starre, Cynthia; Tibboel, Dick; Looman, Caspar; Wijnen, René; Poley, Marten; Ista, Erwin

    2013-10-14

    Central venous catheter-associated bloodstream infections in children are an increasingly recognized serious safety problem worldwide, but are often preventable. Central venous catheter bundles have proved effective to prevent such infections. Successful implementation requires changes in the hospital system as well as in healthcare professionals' behaviour. The aim of the study is to evaluate process and outcome of implementation of a state-of-the-art central venous catheter insertion and maintenance bundle in a large university children's hospital. An interrupted time series design will be used; the study will encompass all children who need a central venous catheter. New state-of-the-art central venous catheter bundles will be developed. The Pronovost-model will guide the implementation process. We developed a tailored multifaceted implementation strategy consisting of reminders, feedback, management support, local opinion leaders, and education. Primary outcome measure is the number of catheter-associated infections per 1000 line-days. The process outcome is degree of adherence to use of these central venous catheter bundles is the secondary outcome. A cost-effectiveness analysis is part of the study. Outcomes will be monitored during three periods: baseline, pre-intervention, and post-intervention for over 48 months. This model-based implementation strategy will reveal the challenges of implementing a hospital-wide safety program. This work will add to the body of knowledge in the field of implementation. We postulate that healthcare workers' willingness to shift from providing habitual care to state-of-the-art care may reflect the need for consistent care improvement. Trial registration: Dutch trials registry, trial # 3635. Dutch trials registry (http://www.trialregister.nl), trial # 3635.

  12. Diagnostic Performance of Wells Score Combined With Point-of-care Lung and Venous Ultrasound in Suspected Pulmonary Embolism.

    PubMed

    Nazerian, Peiman; Volpicelli, Giovanni; Gigli, Chiara; Becattini, Cecilia; Sferrazza Papa, Giuseppe Francesco; Grifoni, Stefano; Vanni, Simone

    2017-03-01

    Lung and venous ultrasound are bedside diagnostic tools increasingly used in the early diagnostic approach of suspected pulmonary embolism (PE). However, the possibility of improving the conventional prediction rule for PE by integrating ultrasound has never been investigated. We performed lung and venous ultrasound in consecutive patients suspected of PE in four emergency departments. Conventional Wells score (Ws) was adjudicated by the attending physician, and ultrasound was performed by one of 20 investigators. Signs of deep venous thrombosis (DVT) at venous ultrasound and signs of pulmonary infarcts or alternative diagnoses at lung ultrasound were considered to recalculate two items of the Ws: signs and symptoms of DVT and alternative diagnosis less likely than PE. The diagnostic performances of the ultrasound-enhanced Ws (USWs) and Ws were then compared after confirmation of the final diagnosis. A total of 446 patients were studied. PE was confirmed in 125 patients (28%). USWs performed significantly better than Ws, with a sensitivity of 69.6% versus 57.6% and a specificity of 88.2% versus 68.2%. In combination with D-dimer, USWs showed an optimal failure rate (0.8%) and a significantly superior efficiency than Ws (32.3% vs. 27.2%). A strategy based on lung and venous ultrasound combined with D-dimer would allow to avoid CT pulmonary angiography in 50.5% of patients with suspected PE, compared to 27.2% when the rule without ultrasound is applied. A pretest risk stratification enhanced by ultrasound of lung and venous performs better than Ws in the early diagnostic process of PE. © 2016 by the Society for Academic Emergency Medicine.

  13. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  14. MR-guided Focused Ultrasound for Uterine Fibroids

    MedlinePlus

    ... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...

  15. Cost effectiveness of different central venous approaches for port placement and use in adult oncology patients: evidence from a randomized three-arm trial.

    PubMed

    Biffi, Roberto; Pozzi, Simonetta; Bonomo, Guido; Della Vigna, Paolo; Monfardini, Lorenzo; Radice, Davide; Rotmensz, Nicole; Zampino, Maria Giulia; Fazio, Nicola; Orsi, Franco

    2014-11-01

    No randomized trials have so far investigated the cost effectiveness of different methods for implantation and use of central venous ports in oncology patients. Overall, 403 patients eligible for receiving intravenous chemotherapy for solid tumours were randomly assigned to implantation of a single type of port, either through a percutaneous landmark access to the internal jugular vein, an ultrasound (US)-guided access to the subclavian vein, or a surgical cut-down access through the cephalic vein at the deltoid-pectoralis groove. Insertion and maintenance costs were estimated by obtaining the charges for an average implant and use, while the costs of the management of complications were analytically assessed. The total cost was defined as the purchase cost plus the insertion cost plus the maintenance cost plus the cost of treatment of the complications, if any. A total of 401 patients were evaluable-132 with the internal jugular vein, 136 with the subclavian vein and 133 with the cephalic vein access. No differences were found for the rate of early complications. The US-guided subclavian insertion site had significantly lower failures. Infections occurred in 1, 3, and 3 patients (internal jugular, subclavian, and cephalic access, respectively; p = 0.464), whereas venous thrombosis was observed in 15, 8, and 11 patients, respectively (p = 0.272). Mean cost for purchase, implantation, diagnosis and treatment of complications in each patient was 2,167.85 for subclavian US-guided, 2,335.87 for cephalic, and 2,384.10 for internal jugular access, respectively (p = 0.0001). US real-time guidance to the subclavian vein resulted in the most cost-effective method of central venous port placement and use.

  16. Intravascular thrombosis as a result of central venous access.

    PubMed

    Biernacka, Jadwiga; Nestorowicz, Andrzej; Wach, Małgorzata

    2002-01-01

    Central venous access represents one of the most basic therapeutic procedures in modern medicine. Unfortunately, numerous advantages that result from maintaining a central venous line are accompanied by some complications among which the venous thrombosis is the most significant clinically. The study was designed to assess frequency and natural history of this complication in the setting at a multi profile clinical hospital. Central venous cannulation was performed by a fully qualified anaesthesiologist in every case. There were 887 cannulations and only 5 patients with clinically significant venous thrombosis. The analysis of the collected data allowed us to state that the frequency of intravascular thrombosis is low, but this complication is often associated with extensive impairment of patency of the central veins. Full recanalization is not always achieved regardless of the treatment applied. Pulmonary embolism in the course of central venous thrombosis was diagnosed in one patient only and appeared as a multiple and fine X-ray infiltrates. It seems that in the presence of permanent or even life threatening complications of central venous thrombosis their risk should be minimized by frequent examination of the cannulation site and early initiation of antithrombotic treatment.

  17. Contrast-enhanced ultrasound in portal venous system aneurysms: a multi-center study.

    PubMed

    Tana, Claudio; Dietrich, Christoph F; Badea, Radu; Chiorean, Liliana; Carrieri, Vincenzo; Schiavone, Cosima

    2014-12-28

    To investigate contrast-enhanced ultrasound (CEUS) findings in portal venous system aneurysms (PVSAs). In this multi-center, retrospective, case series study, we evaluated CEUS features of seven cases of PVSAs that were found incidentally on conventional ultrasound in the period 2007-2013. Three Ultrasound Centers were involved (Chieti, Italy, Bad Mergentheim, Germany, and Cluj-Napoca, Romania). All patients underwent CEUS with Sonovue(®) (Bracco, Milan, Italy) at a standard dose of 2.4 mL, followed by 10 mL of 0.9% saline solution. The examinations were performed using multifrequency transducers and low mechanical index. We considered aneurysmal a focal dilatation of the portal venous system with a size that was significantly greater than the remaining segments of the same vein, and that was equal or larger than 21 mm for the extrahepatic segments of portal venous system, main portal vein and bifurcation, and 9 mm for the intrahepatic branches. After contrast agent injection, all PVSAs were not enhanced in the arterial phase (starting 8-22 s). All PVSAs were then rapidly enhanced in the early portal venous phase (starting three to five seconds after the arterial phase, 11-30 s), with persistence and slow washout of the contrast agent in the late phase (starting 120 s). In all patients, CEUS confirmed the presence of a "to-and-fro" flow by showing a swirling pattern within the dilatation in the early portal venous phase. CEUS also improved the delineation of the lumen, and was reliable in showing its patency degree and integrity of walls. In one patient, CEUS showed a partial enhancement of the lumen with a uniformly nonenhancing area in the portal venous and late phases, suggesting thrombosis. In our case series, we found that CEUS could be useful in the assessment and follow-up of a PVSA. Further studies are needed to validate its diagnostic accuracy.

  18. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajan, Dheeraj K., E-mail: dheeraj.rajan@uhn.on.ca; Saluja, Jasdeep S.

    2007-07-15

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm.more » The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is

  19. [The unnecessary application of central venous catheterization in surgical patients].

    PubMed

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on

  20. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators.

    PubMed

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong; Zhu, Du-Ming

    2017-04-01

    The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture.

  1. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators

    PubMed Central

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong

    2017-01-01

    Background The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. Methods We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. Results The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. Conclusions The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture. PMID:28523170

  2. External jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies.

    PubMed

    Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber

    2011-12-01

    Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.

  3. Lymphatic Leak Complicating Central Venous Catheter Insertion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnacle, Alex M., E-mail: alexbarnacle@yahoo.co.uk; Kleidon, Tricia M.

    2005-12-15

    Many of the risks associated with central venous access are well recognized. We report a case of inadvertent lymphatic disruption during the insertion of a tunneled central venous catheter in a patient with raised left and right atrial pressures and severe pulmonary hypertension, which led to significant hemodynamic instability. To our knowledge, this rare complication is previously unreported.

  4. Central Venous Occlusion in the Hemodialysis Patient.

    PubMed

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  5. Ultrasound-guided peripheral nerve blockade.

    PubMed

    Chin, Ki Jinn; Chan, Vincent

    2008-10-01

    The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.

  6. Transcranial MR-Guided Focused Ultrasound: A Review of the Technology and Neuro Applications

    PubMed Central

    Ghanouni, Pejman; Pauly, Kim Butts; Elias, W. Jeff; Henderson, Jaimie; Sheehan, Jason; Monteith, Stephen; Wintermark, Max

    2015-01-01

    MR guided focused ultrasound is a new, minimally invasive method of targeted tissue thermal ablation that may be of use to treat central neuropathic pain, essential tremor, Parkinson tremor, and brain tumors. The system has also been used to temporarily disrupt the blood-brain barrier to allow targeted drug delivery to brain tumors. This article reviews the physical principles of MR guided focused ultrasound and discusses current and potential applications of this exciting technology. PMID:26102394

  7. Central venous stenosis among hemodialysis patients is often not associated with previous central venous catheters.

    PubMed

    Kotoda, Atsushi; Akimoto, Tetsu; Kato, Maki; Kanazawa, Hidenori; Nakata, Manabu; Sugase, Taro; Ogura, Manabu; Ito, Chiharu; Sugimoto, Hideharu; Muto, Shigeaki; Kusano, Eiji

    2011-01-01

    It is widely assumed that central venous stenosis (CVS) is most commonly associated with previous central venous catheterization among the chronic hemodialysis (HD) patients. We evaluated the validity of this assumption in this retrospective study. The clinical records from 2,856 consecutive HD patients with vascular access failure during a 5-year period were reviewed, and a total of 26 patients with symptomatic CVS were identified. Combined with radiological findings, their clinical characteristics were examined. Only seven patients had a history of internal jugular dialysis catheterization. Diagnostic multidetector row computed tomography angiography showed that 7 of the 19 patients with no history of catheterization had left innominate vein stenosis due to extrinsic compression between the sternum and arch vessels. These patients had a shorter period from the time of creation of the vascular access to the initial referral (9.2 ± 7.6 months) than the rest of the patients (35.5 ± 18.6 months, p = 0.0017). Our findings suggest that cases without a history of central venous catheterization may not be rare among the HD patients with symptomatic CVS. However, those still need to be confirm by larger prospective studies of overall chronic HD patients with symptomatic CVS.

  8. Combining central venous-to-arterial partial pressure of carbon dioxide difference and central venous oxygen saturation to guide resuscitation in septic shock.

    PubMed

    Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi

    2013-12-01

    Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.

  9. Instructional design affects the efficacy of simulation-based training in central venous catheterization.

    PubMed

    Craft, Christopher; Feldon, David F; Brown, Eric A

    2014-05-01

    Simulation-based learning is a common educational tool in health care training and frequently involves instructional designs based on Experiential Learning Theory (ELT). However, little research explores the effectiveness and efficiency of different instructional design methodologies appropriate for simulations. The aim of this study was to compare 2 instructional design models, ELT and Guided Experiential Learning (GEL), to determine which is more effective for training the central venous catheterization procedure. Using a quasi-experimental randomized block design, nurse anesthetists completed training under 1 of the 2 instructional design models. Performance was assessed using a checklist of central venous catheterization performance, pass rates, and critical action errors. Participants in the GEL condition performed significantly better than those in the ELT condition on the overall checklist score after controlling for individual practice time (F[1, 29] = 4.021, P = .027, Cohen's d = .71), had higher pass rates (P = .006, Cohen's d = 1.15), and had lower rates of failure due to critical action errors (P = .038, Cohen's d = .81). The GEL model of instructional design is significantly more effective than ELT for simulation-based learning of the central venous catheterization procedure, yielding large differences in effect size. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Teaching aseptic technique for central venous access under ultrasound guidance: a randomized trial comparing didactic training alone to didactic plus simulation-based training.

    PubMed

    Latif, Rana K; Bautista, Alexander F; Memon, Saima B; Smith, Elizabeth A; Wang, Chenxi; Wadhwa, Anupama; Carter, Mary B; Akca, Ozan

    2012-03-01

    Our goal was to determine whether simulation combined with didactic training improves sterile technique during ultrasound (US)-guided central venous catheter (CVC) insertion compared with didactic training alone among novices. We hypothesized that novices who receive combined didactic and simulation-based training would perform similarly to experienced residents in aseptic technique, knowledge, and perception of comfort during US-guided CVC insertion on a simulator. Seventy-two subjects were enrolled in a randomized, controlled trial of an educational intervention. Fifty-four novices were randomized into either the didactic group or the simulation combined with didactic group. Both groups received didactic training but the simulation combined with didactic group also received simulation-based CVC insertion training. Both groups were tested by demonstrating US-guided CVC insertion on a simulator. Aseptic technique was scored on 8 steps as "yes/no" and also using a 7-point Likert scale with 7 being "excellent technique" by a rater blinded to subject randomization. After initial testing, the didactic group was offered simulation-based training and retesting. Both groups also took a pre- and posttraining test of knowledge and rated their comfort with US and CVC insertion pre- and posttraining on a 5-point Likert scale. Subsequently, 18 experienced residents also took the test of knowledge, rated their comfort level, and were scored while performing aseptic US-guided CVC insertion using a simulator. The simulation combined with didactic group achieved a 167% (95% confidence interval [CI] 133%-167%) incremental increase in yes/no scores and 115% (CI 112%-127%) incremental increase in Likert scale ratings on aseptic technique compared with novices in the didactic group. Compared with experienced residents, simulation combined with didactic trained novices achieved an increase in aseptic scores with a 33.3% (CI 16.7%-50%) increase in yes/no ratings and a 20% (CI 13

  11. Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement

    PubMed Central

    Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying

    2015-01-01

    Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758

  12. A New Technique for Femoral Venous Access in Infants Using Arterial Injection Venous Return Guidance

    PubMed Central

    Ebishima, Hironori; Kitano, Masataka; Kurosaki, Kenichi; Shiraishi, Isao

    2017-01-01

    Objectives: Although venography guidance is helpful for central venous catheter placement, it is sometimes difficult to place a peripheral intravenous cannula for enhancement. We designed a new technique for establishing femoral venous access using venography guidance in the return phase of peripheral arteriography. This new technique was named arterial injection venous return guidance. Here we assessed the efficacy and safety of arterial injection venous return guidance. Methods: We reviewed data of 29 infants less than 6 months old undergoing catheter intervention at our institute in 2014. Of the 29 patients, femoral venous cannulation was performed using arterial injection venous return guidance in 5 patients, venography in 20 patients, and the landmark method in 4 patients. The technical success rates and incidence of complications were compared. Results: The overall success rates were 100% in the arterial injection venous return-guided and venography-guided groups. The mean procedure duration and mean contrast material injection time were similar between the groups. The contrast effect on the femoral vein in the arterial injection venous return-guided group was lower than that in the venography-guided group, but adequate for surgery. The overall complication rate was 17%, and obstruction of previously placed intravenous catheters was the most common complication. Conclusions: Therefore, the arterial injection venous return guidance technique was as safe and efficient as venography for establishing venous access. PMID:29034015

  13. Management of end-stage central venous access in children referred for possible small bowel transplantation.

    PubMed

    Rodrigues, A F; van Mourik, I D M; Sharif, K; Barron, D J; de Giovanni, J V; Bennett, J; Bromley, P; Protheroe, S; John, P; de Ville de Goyet, J; Beath, S V

    2006-04-01

    The 3-year survival after small bowel transplantation (SBTx) has improved to between 73% and 88%. Impaired venous access for parenteral nutrition can be an indication for SBTx in children with chronic intestinal failure. To report our experience in management of children with extreme end-stage venous access. The study consisted of 6 children (all boys), median age of assessment 27 months (range, 13-52 months), diagnosed with total intestinal aganglionosis (1), protracted diarrhea (1), and short bowel syndrome (4), of which gastroschisis (2) and malrotation with midgut volvulus (2) were the causes. All had a documented history of more than 10 central venous catheter insertions previously. All had venograms, and 1 child additionally had a magnetic resonance angiogram to evaluate venous access. Five of 6 presented with thrombosis of the superior vena cava (SVC) and/or inferior vena cava. Venous access was reestablished as follows: transhepatic venous catheters (5), direct intra-atrial catheter via midline sternotomy (4), azygous venous catheters (2), dilatation of left subclavian vein after passage of a guide wire and then placing a catheter to reach the right atrium (1), radiological recanalization of the SVC and placement of a central venous catheter in situ (1), and direct puncture of SVC stump(1). Complications included serous pleural effusion after direct intra-atrial line insertion, which resolved after chest drain insertion (1), displacement of transhepatic catheter needing repositioning (2), and SVC stent narrowing requiring repeated balloon dilatation. Four children with permanent intestinal failure on assessment were offered SBTx, 3 of which were transplanted and were established on full enteral nutrition; the family of 1 child declined the procedure. In the remaining 2 children in whom bowel adaptation was still a possibility, attempts were made to provide adequate central venous access as feeds and drug manipulations were undertaken. One of them received

  14. Infection and natural history of emergency department-placed central venous catheters.

    PubMed

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  15. Central venous access: techniques and indications in oncology.

    PubMed

    Marcy, Pierre-Yves

    2008-10-01

    Long lines can be inserted centrally or peripherally through patent veins into the central venous system down to the atrial caval junction. Traditionally surgeons, anesthetists, cardiologists and more recently interventional radiologists have been placing them using vein cutdown or percutaneous needle puncture techniques. Typical candidates for implanted venous catheters are cancer patients undergoing long-term chemotherapy. The most important issues, in addition to the patency of central veins and the history of previous indwelling catheters, pacewires or venous thrombosis, are the patient's performance status, body mass index, medical history and respiratory status, and the relevant technique. The present article will give an overview of the radiological and surgical implantation techniques and will highlight the impact of imaging means on the technical feasibility, assessment and treatment of device-related complications.

  16. [Venous thrombosis associated with central venous catheter use in patients with cancer].

    PubMed

    Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto

    2015-01-01

    The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  17. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  18. Training Surgical Residents With a Haptic Robotic Central Venous Catheterization Simulator.

    PubMed

    Pepley, David F; Gordon, Adam B; Yovanoff, Mary A; Mirkin, Katelin A; Miller, Scarlett R; Han, David C; Moore, Jason Z

    Ultrasound guided central venous catheterization (CVC) is a common surgical procedure with complication rates ranging from 5 to 21 percent. Training is typically performed using manikins that do not simulate anatomical variations such as obesity and abnormal vessel positioning. The goal of this study was to develop and validate the effectiveness of a new virtual reality and force haptic based simulation platform for CVC of the right internal jugular vein. A CVC simulation platform was developed using a haptic robotic arm, 3D position tracker, and computer visualization. The haptic robotic arm simulated needle insertion force that was based on cadaver experiments. The 3D position tracker was used as a mock ultrasound device with realistic visualization on a computer screen. Upon completion of a practice simulation, performance feedback is given to the user through a graphical user interface including scoring factors based on good CVC practice. The effectiveness of the system was evaluated by training 13 first year surgical residents using the virtual reality haptic based training system over a 3 month period. The participants' performance increased from 52% to 96% on the baseline training scenario, approaching the average score of an expert surgeon: 98%. This also resulted in improvement in positive CVC practices including a 61% decrease between final needle tip position and vein center, a decrease in mean insertion attempts from 1.92 to 1.23, and a 12% increase in time spent aspirating the syringe throughout the procedure. A virtual reality haptic robotic simulator for CVC was successfully developed. Surgical residents training on the simulation improved to near expert levels after three robotic training sessions. This suggests that this system could act as an effective training device for CVC. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  19. Nerve conduction studies are safe in patients with central venous catheters.

    PubMed

    London, Zachary N; Mundwiler, Andrew; Oral, Hakan; Gallagher, Gary W

    2017-08-01

    It is unknown if central venous catheters bypass the skin's electrical resistance and engender a risk of nerve conduction study-induced cardiac arrhythmia. The objective of this study is to determine if nerve conduction studies affect cardiac conduction and rhythm in patients with central venous catheters. Under continuous 12-lead electrocardiogram monitoring, subjects with and without central venous catheters underwent a series of upper extremity nerve conduction studies. A cardiologist reviewed the electrocardiogram tracings for evidence of cardiac conduction abnormality or arrhythmia. Ten control subjects and 10 subjects with central venous catheters underwent the nerve conduction study protocol. No malignant arrhythmias or conduction abnormalities were noted in either group. Nerve conduction studies of the upper extremities, including both proximal stimulation and repetitive stimulation, do not appear to confer increased risk of cardiac conduction abnormality in those patients with central venous catheters who are not critically ill or have a prior history of arrhythmia. Muscle Nerve 56: 321-323, 2017. © 2016 Wiley Periodicals, Inc.

  20. Personalized Learning in Medical Education: Designing a User Interface for a Dynamic Haptic Robotic Trainer for Central Venous Catheterization

    PubMed Central

    Yovanoff, Mary; Pepley, David; Mirkin, Katelin; Moore, Jason; Han, David; Miller, Scarlett

    2017-01-01

    While Virtual Reality (VR) has emerged as a viable method for training new medical residents, it has not yet reached all areas of training. One area lacking such development is surgical residency programs where there are large learning curves associated with skill development. In order to address this gap, a Dynamic Haptic Robotic Trainer (DHRT) was developed to help train surgical residents in the placement of ultrasound guided Internal Jugular Central Venous Catheters and to incorporate personalized learning. In order to accomplish this, a 2-part study was conducted to: (1) systematically analyze the feedback given to 18 third year medical students by trained professionals to identify the items necessary for a personalized learning system and (2) develop and experimentally test the usability of the personalized learning interface within the DHRT system. The results can be used to inform the design of VR and personalized learning systems within the medical community. PMID:29123361

  1. Central Venous Catheter Placement in the Left Internal Jugular Vein Complicated by Perforation of the Left Brachiocephalic Vein and Massive Hemothorax: A Case Report.

    PubMed

    Wetzel, Lindsay R; Patel, Priyesh R; Pesa, Nicholas L

    2017-07-01

    An elderly male presented for emergent repair of a ruptured abdominal aortic aneurysm. For anticipated volume resuscitation, vasopressor administration, and hemodynamic monitoring, a large-bore central venous catheter was placed in the left internal jugular vein under ultrasound guidance before surgical incision. Initially, there were no readily apparent signs of venous perforation. However, a massive left hemothorax developed because of perforation of the brachiocephalic vein and violation of the pleural space. This case report discusses both prevention and management of such a complication.

  2. Manual lymphatic drainage in chronic venous disease: a duplex ultrasound study.

    PubMed

    Dos Santos Crisóstomo, Rute Sofia; Candeias, Miguel Sandu; Ribeiro, Ana Margarida Martins; da Luz Belo Martins, Catarina; Armada-da-Silva, Paulo As

    2014-12-01

    To compare the effect of call-up and reabsorption maneuvers of manual lymphatic drainage on blood flow in femoral vein and great saphenous vein in patients with chronic venous disease and healthy controls. Forty-one subjects participated in this study (mean age: 42.68(15.23)), 23 with chronic venous disease (chronic venous disease group) with clinical classification C1-5 of clinical-etiological-anatomical-pathological (CEAP) and 18 healthy subjects (control group). Call-up and reabsorption maneuvers were randomly applied in the medial aspect of the thigh. The cross-sectional areas, as well as the peak and the mean blood flow velocity at femoral vein and great saphenous vein, were assessed by Duplex ultrasound at the baseline and during maneuvers. The venous flow volume changes were calculated. The venous flow volume in femoral vein and great saphenous vein increased during both manual lymphatic drainage maneuvers and in both groups (P < 0.05). The two maneuvers had a similar effect on femoral vein and great saphenous vein hemodynamics, and in both the chronic venous disease and control groups. As a result of the call-up maneuver, the flow volume augmentations, as a result of call-up maneuver, decreased with the severity of chronic venous disease in those patients measured by the clinical classification of CEAP (r = -0.64; P = 0.03). Manual lymphatic drainage increases the venous blood flow in the lower extremity with a magnitude that is independent from the specific maneuver employed or the presence of chronic venous disease. Therefore, manual lymphatic drainage may be an alternative strategy for the treatment and prevention of venous stasis complications in chronic venous disease. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nicholson, Tony, E-mail: Tony.Nicholson@leedsth.nhs.uk; Ettles, Duncan; Robinson, Graham

    2004-01-15

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred withmore » carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device.« less

  4. Comparison of delayed complications of central venous catheters placed surgically or radiologically in pediatric oncology patients.

    PubMed

    Basford, Tavis J; Poenaru, Dan; Silva, Mariana

    2003-05-01

    Pediatric central venous catheters (CVCs) traditionally have been placed surgically, guided by anatomic landmarks. Increasingly, interventional radiology services are inserting CVCs using ultrasound image guidance. This study compares the frequency of delayed complications in CVCs placed surgically or radiologically in a pediatric oncology population. Data on CVCs placed in one academic institution over 10 years were collected and analyzed retrospectively. Main outcomes assessed were infectious complications, mechanical complications, and premature catheter removal. Ninety-eight CVCs-comprising 52 external tunneled catheters (ETCs) and 46 subcutaneous ports-were assessed in 67 patients. Median patient age was 6.1 years for children with external catheters and 7.8 years for those with ports. Both infectious and mechanical complications were significantly more common among surgically placed ETCs than those placed radiologically (P <.05). Complications per 1,000 catheter days and premature removal showed a trend toward greater frequency among surgical ETCs, although this did not reach statistical significance. No consistent trends were seen in complications among ports. Pediatric patients with CVCs, especially those with external catheters, experience frequent delayed complications. Patients with radiologically inserted ETCs may encounter fewer complications than those with surgically placed ones. This corroborates previous reports in the literature suggesting image-guided CVC placement as a preferable alternative to traditional techniques. Copyright 2003 Elsevier Inc. All rights reserved.

  5. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    NASA Astrophysics Data System (ADS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-07-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.

  6. Ultrasound-Guided Regional Anesthesia Simulation Training: A Systematic Review.

    PubMed

    Chen, Xiao Xu; Trivedi, Vatsal; AlSaflan, AbdulHadi A; Todd, Suzanne Clare; Tricco, Andrea C; McCartney, Colin J L; Boet, Sylvain

    Ultrasound-guided regional anesthesia (UGRA) has become the criterion standard of regional anesthesia practice. Ultrasound-guided regional anesthesia teaching programs often use simulation, and guidelines have been published to help guide URGA education. This systematic review aimed to examine the effectiveness of simulation-based education for the acquisition and maintenance of competence in UGRA. Studies identified in MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and ERIC were included if they assessed simulation-based UGRA teaching with outcomes measured at Kirkpatrick level 2 (knowledge and skills), 3 (transfer of learning to the workplace), or 4 (patient outcomes). Two authors independently reviewed all identified references for eligibility, abstracted data, and appraised quality. After screening 176 citations and 45 full-text articles, 12 studies were included. Simulation-enhanced training improved knowledge acquisition (Kirkpatrick level 2) when compared with nonsimulation training. Seven studies measuring skill acquisition (Kirkpatrick level 2) found that simulation-enhanced UGRA training was significantly more effective than alternative teaching methods or no intervention. One study measuring transfer of learning into the clinical setting (Kirkpatrick level 3) found no difference between simulation-enhanced UGRA training and non-simulation-based training. However, this study was discontinued early because of technical challenges. Two studies examined patient outcomes (Kirkpatrick level 4), and one of these found that simulation-based UGRA training improved patient outcomes compared with didactic teaching. Ultrasound-guided regional anesthesia knowledge and skills significantly improved with simulation training. The acquired UGRA skills may be transferred to the clinical setting; however, further studies are required to confirm these changes translate to improved patient outcomes.

  7. Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation.

    PubMed

    Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y

    2017-08-01

    To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.

  8. Case report: Unilateral conduction hearing loss due to central venous occlusion.

    PubMed

    Ribeiro, Phillip; Patel, Swetal; Qazi, Rizwan A

    2016-05-07

    Central venous stenosis is a well-known complication in patients with vascular access for hemodialysis. We report two cases involving patients on hemodialysis with arteriovenous fistulas who developed reversible unilateral conductive hearing loss secondary to critical stenosis of central veins draining the arteriovenous dialysis access. A proposed mechanism for the patients' reversible unilateral hearing loss is pterygoid venous plexus congestion leading to decreased Eustachian tube patency. Endovascular therapy was conducted to treat the stenosis and the hearing loss of both patients was returned to near normal after successful central venous angioplasty.

  9. Noninvasive measurement of central venous pressure

    NASA Technical Reports Server (NTRS)

    Webster, J. G.; Mastenbrook, S. M., Jr.

    1972-01-01

    A technique for the noninvasive measurement of CVP in man was developed. The method involves monitoring venous velocity at a point in the periphery with a transcutaneous Doppler ultrasonic velocity meter while the patient performs a forced expiratory maneuver. The idea is the CVP is related to the value of pressure measured at the mouth which just stops the flow in the vein. Two improvements were made over the original procedure. First, the site of venous velocity measurement was shifted from a vein at the antecubital fossa (elbow) to the right external jugular vein in the neck. This allows for sensing more readily events occurring in the central veins. Secondly, and perhaps most significantly, a procedure for obtaining a curve of relative mean venous velocity vs mouth pressure was developed.

  10. Internal jugular vein thrombosis associated with venous hypoplasia and protein S deficiency revealed by ultrasonography.

    PubMed

    Lim, Byung Gun; Kim, Young Min; Kim, Heezoo; Lim, Sang Ho; Lee, Mi Kyoung

    2011-12-01

    A 41-year-old woman, who had no thrombotic risk factors and past history except congenital scoliosis, underwent central venous catheterization (CVC) before correction of the scoliosis. When internal jugular vein (IJV) catheterization using the anatomical landmark technique failed, CVC under ultrasound guidance was tried. As a consequence, thrombosis and hypoplasia of the right IJV were incidentally detected by ultrasonography. Central venous catheters were then successfully placed in other veins under ultrasound guidance. Also, after examinations to rule out the possibility of pulmonary embolism and to clarify the causes of the IJV thrombosis, the patient was found to have protein S deficiency. CVC under ultrasound guidance should be recommended to prevent the failure of cannulation and complications such as thromboembolism in patients who could possibly have anomalies of vessels as a result of anatomical deformities caused by severe scoliosis, even if patients do not have thrombotic risk factors such as a history of central catheter insertion or intravenous drug abuse, cancer, advanced age, cerebral infarction, and left ventricular dysfunction. Also, if venous thrombosis is found in patients without predisposing risk factors, one should ascertain the cause of the hypercoagulable state, for example protein S deficiency, and perform appropriate treatment and prevention of venous thromboembolism.

  11. Radiofrequency Guide Wire Recanalization of Venous Occlusions in Patients with Malignant Superior Vena Cava Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Robert M.; David, Elizabeth; Pugash, Robyn A.

    Fibrotic central venous occlusions in patients with thoracic malignancy and prior radiotherapy can be impassable with standard catheters and wires, including the trailing or stiff end of a hydrophilic wire. We report two patients with superior vena cava syndrome in whom we successfully utilized a radiofrequency guide wire (PowerWire, Baylis Medical, Montreal, Quebec, Canada) to perforate through the occlusion and recanalize the occluded segment to alleviate symptoms.

  12. Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock

    NASA Astrophysics Data System (ADS)

    Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.

    2013-03-01

    Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.

  13. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  14. Strategies for prevention of iatrogenic inferior vena cava filter entrapment and dislodgement during central venous catheter placement.

    PubMed

    Wu, Alex; Helo, Naseem; Moon, Eunice; Tam, Matthew; Kapoor, Baljendra; Wang, Weiping

    2014-01-01

    Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication. A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified. A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration. Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  15. Effect of intraoperative transesophageal Doppler-guided fluid therapy versus central venous pressure-guided fluid therapy on renal allograft outcome in patients undergoing living donor renal transplant surgery: a comparative study.

    PubMed

    Srivastava, Divya; Sahu, Sandeep; Chandra, Abhilash; Tiwari, Tanmay; Kumar, Sanjay; Singh, P K

    2015-12-01

    Transesophageal Doppler (TED)-guided intraoperative fluid therapy has shown to noninvasively optimize intravascular volume and reduce postoperative morbidity. The aim of this study was to compare the effects of Doppler-guided intraoperative fluid administration and central venous pressure (CVP)-guided fluid therapy on renal allograft outcome and postoperative complications. A prospective nonrandomized active controlled study was conducted on end-stage renal disease patients scheduled for living donor renal transplant surgery. 110 patients received intraoperative fluid guided by corrected flow time (FTc) and variation in stroke volume values obtained by continuous TED monitoring. Data of 104 patients in whom intraoperative fluid administration was guided by CVP values were retrospectively obtained for a control. The amount of intraoperative fluid given in the study group (12.20 ± 4.24 ml/kg/h) was significantly lower than in the controls (22.21 ± 4.67 ml/kg/h). The amount of colloid used was also significantly less and fewer recipients were seen to require colloid (69 vs 85%). The mean arterial pressures were comparable throughout. CVP reached was 7.18 ± 3.17 mmHg in the study group. It was significantly higher in the controls (13.42 ± 3.12 mmHg). The postoperative graft function and rate of dysfunction were comparable. Side-effects like postoperative dyspnoea (4.8 vs 0%) and tissue edema (9.6 vs 2.7%) were higher in the controls. FTc-guided intraoperative fluid therapy achieved the same rate of immediate graft function as CVP-guided fluid therapy but used a significantly less amount of fluid. The incidence of postoperative complications related to fluid overload was also reduced. The use of TED may replace invasive central line insertions in the future.

  16. Single-stick tunneled central venous access using the jugular veins in infants weighing less than 5 kg.

    PubMed

    Lindquester, Will S; Hawkins, C Matthew; Monroe, Eric J; Gill, Anne E; Shivaram, Giridhar M; Seidel, F Glen; Lungren, Matthew P

    2017-11-01

    Despite the demonstrated feasibility of the single-stick technique in the femoral vein, its use in neonates and infants for placing central lines in internal and external jugular veins has not been reported. Describe and assess the safety and efficacy of tunneled jugular central venous catheter placement performed under ultrasound (US) and fluoroscopic guidance in neonates and infants weighing <5 kg using the single-stick technique at three tertiary pediatric hospitals. Thirty-three children weighing less than 5 kg received tunneled central venous access in either internal or external jugular veins using the single-stick technique. Patient history, procedural records and clinical follow-up documents were retrospectively reviewed. Complication rates were compared to those of 41 patients receiving single-stick femoral central lines. Technical complications occurred during one (3.0%) jugular placement with the patient having a failed right-side attempt with subsequent successful left-side placement. The catheters did not last the entire course of treatment in three (9.1%) patients with jugular lines. One patient had the catheter removed due to concern for infection, one catheter was accidentally removed during dressing changes, and one catheter was displaced and subsequently exchanged. Of patients receiving femoral central lines, 1 (2.4%) had a technical complication and 5 catheters (12.2%) did not last the entire course of treatment. The placement of tunneled central venous catheters in neonates/infants <5 kg is safe and technically feasible using the internal/external jugular vein via the single-stick technique. By theoretically reducing the risks of catheter infection by avoiding the diaper area and thrombosis by using larger veins, it may be preferable in certain patient populations.

  17. Central Venous Catheter-related Fungemia Caused by Rhodotorula glutinis.

    PubMed

    Miglietta, Fabio; Letizia Faneschi, Maria; Braione, Adele; Palumbo, Claudio; Rizzo, Adriana; Lobreglio, Giambattista; Pizzolante, Maria

    2015-01-01

    Bloodstream infection due to Rhodotorula glutinis is extremely rare and mostly associated with underlying immunosuppression or cancer. Vascular access devices provide the necessary surfaces for biofilm formation and are currently responsible for a significant percentage of human infections. In this work, we describe a rare case of central venous catheter-related Rhodotorula glutinis fungemia in a female patient with acute myelogenous leukemia in remission. The timely removal of central venous catheter was an essential element for overcoming this CVC-related Rhodotorula fungemia.

  18. Outcomes of ultrasound guided renal mass biopsies.

    PubMed

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  19. Advanced Technologies in Trauma Critical Care Management

    DTIC Science & Technology

    2012-01-01

    CVL, central venous line; DVT, deep venous thrombosis; FAST, focused assessment with sonography for trauma; IVC, inferior vena cava; PIV, peripheral...either for a 1-time view of the target vein or in real time using a 1- or 2-person technique. Recently, ultrasound-guided subclavian central venous ...technologies such as bedside echocardiography, central venous pressure monitoring, and cardiac electrical velocimetry. These limitations aside, it is

  20. Imaging of head and neck venous malformations.

    PubMed

    Flis, Christine M; Connor, Stephen E

    2005-10-01

    Venous malformations (VMs) are non proliferative lesions that consist of dysplastic venous channels. The aim of imaging is to characterise the lesion and define its anatomic extent. We will describe the plain film, ultrasound (US) (including colour and duplex Doppler), computed tomography (CT), magnetic resonance imaging (MRI), conventional angiographic and direct phlebographic appearances of venous malformations. They will be illustrated at a number of head and neck locations, including orbit, oral cavity, superficial and deep facial space, supraglottic and intramuscular. An understanding of the classification of such vascular anomalies is required to define the correct therapeutic procedure to employ. Image-guided sclerotherapy alone or in combination with surgery is now the first line treatment option in many cases of head and neck venous malformations, so the radiologist is now an integral part of the multidisciplinary management team.

  1. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  2. Correlation between central venous pressure and peripheral venous pressure with passive leg raise in patients on mechanical ventilation.

    PubMed

    Kumar, Dharmendra; Ahmed, Syed Moied; Ali, Shahna; Ray, Utpal; Varshney, Ankur; Doley, Kashmiri

    2015-11-01

    Central venous pressure (CVP) assesses the volume status of patients. However, this technique is not without complications. We, therefore, measured peripheral venous pressure (PVP) to see whether it can replace CVP. To evaluate the correlation and agreement between CVP and PVP after passive leg raise (PLR) in critically ill patients on mechanical ventilation. Prospective observational study in Intensive Care Unit. Fifty critically ill patients on mechanical ventilation were included in the study. CVP and PVP measurements were taken using a water column manometer. Measurements were taken in the supine position and subsequently after a PLR of 45°. Pearson's correlation and Bland-Altman's analysis. This study showed a fair correlation between CVP and PVP after a PLR of 45° (correlation coefficient, r = 0.479; P = 0.0004) when the CVP was <10 cmH2O. However, the correlation was good when the CVP was >10 cmH2O. Bland-Altman analysis showed 95% limits of agreement to be -2.912-9.472. PVP can replace CVP for guiding fluid therapy in critically ill patients.

  3. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    PubMed

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  4. Hospitalists' ability to use hand-carried ultrasound for central venous pressure estimation after a brief training intervention: a pilot study.

    PubMed

    Martin, L David; Ziegelstein, Roy C; Howell, Eric E; Martire, Carol; Hellmann, David B; Hirsch, Glenn A

    2013-12-01

    Access to hand-carried ultrasound technology for noncardiologists has increased significantly, yet development and evaluation of training programs are limited. We studied a focused program to teach hospitalists image acquisition of inferior vena cava (IVC) diameter and IVC collapsibility index with interpretation of estimated central venous pressure (CVP). Ten hospitalists completed an online educational module prior to attending a 1-day in-person training session that included directly supervised IVC imaging on volunteer subjects. In addition to making quantitative assessments, hospitalists were also asked to visually assess whether the IVC collapsed more than 50% during rapid inspiration or a sniff maneuver. Skills in image acquisition and interpretation were assessed immediately after training on volunteer patients and prerecorded images, and again on volunteer patients at least 6 weeks later. Eight of 10 hospitalists acquired adequate IVC images and interpreted them correctly on 5 of the 5 volunteer subjects and interpreted all 10 prerecorded images correctly at the end of the 1-day training session. At 7.4 ± 0.7 weeks (range, 6.9-8.6 weeks) follow-up, 9 of 10 hospitalists accurately acquired and interpreted all IVC images in 5 of 5 volunteers. Hospitalists were also able to accurately determine whether the IVC collapsibility index was more than 50% by visual assessment in 180 of 198 attempts (91% of the time). After a brief training program, hospitalists acquired adequate skills to perform and interpret hand-carried ultrasound IVC images and retained these skills in the near term. Though calculation of the IVC collapsibility index is more accurate, coupling a qualitative assessment with the IVC maximum diameter measurement may be acceptable in aiding bedside estimation of CVP. © 2013 Society of Hospital Medicine.

  5. Evaluation of a central venous catheter tip placement for superior vena cava–subclavian central venous catheterization using a premeasured length

    PubMed Central

    Kwon, Hyun-Jung; Jeong, Young-Il; Jun, In-Gu; Moon, Young-Jin; Lee, Yu-Mi

    2018-01-01

    Abstract Subclavian central venous catheterization is a common procedure for which misplacement of the central venous catheter (CVC) is a frequent complication that can potentially be fatal. The carina is located in the mid-zone of the superior vena cava (SVC) and is considered a reliable landmark for CVC placement in chest radiographs. The C-length, defined as the distance from the edge of the right transverse process of the first thoracic spine to the carina, can be measured in posteroanterior chest radiographs using a picture archiving and communication system. To evaluate the placement of the tip of the CVC in subclavian central venous catheterizations using the C-length, we reviewed the medical records and chest radiographs of 122 adult patients in whom CVC catheterization was performed (from January 2012 to December 2014) via the right subclavian vein using the C-length. The tips of all subclavian CVCs were placed in the SVC using the C-length. No subclavian CVC entered the right atrium. Tip placement was not affected by demographic characteristics such as age, sex, height, weight, and body mass index. The evidence indicates that the C-length on chest radiographs can be used to determine the available insertion length and place the right subclavian CVC tip into the SVC. PMID:29480861

  6. [Prophylaxis of thrombosis induced by chemotherapy or central venous catheters].

    PubMed

    Voog, Eric; Lazard, Eric; Juhel, Laurence

    2007-02-01

    Deep venous thrombosis and pulmonary embolism are well-recognized complications of cancer, especially in patients with a venous access device or receiving chemotherapy. The pathogenic mechanisms of thrombosis in cancer patients involve a complex interaction between the patient's tumor cells and hemostatic system. Chemotherapy and central venous catheters increase the risk of thromboembolism. Prophylactic treatment for these patients remains controversial. We conducted a systematic literature review using the Medline database and abstract books for meetings of the American Society of Clinical Oncology and the American Society of Hematology since 2000. Our search focused on clinical trials of primary prevention of venous catheter-related thrombosis or prevention of chemotherapy-related venous thromboembolism in cancer patients. Ten studies evaluating primary prevention of patients with central catheters were identified, and their results are contradictory. Currently only one study has examined prevention of chemotherapy-related venous thromboembolism, in women with metastatic breast cancer. Its results cannot be extrapolated to other tumors. Systematic prophylaxis cannot yet be recommended. In the near future we must improve our knowledge of the risk factors of these complications. Prophylaxis should be individualized for each patient. New anticoagulant drugs should be tested in cancer patients.

  7. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    PubMed

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  8. [Ultrasound guided percutaneous nephrolithotripsy].

    PubMed

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  9. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    PubMed

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  10. Central venous catheterization for parenteral nutrition.

    PubMed Central

    Padberg, F T; Ruggiero, J; Blackburn, G L; Bistrian, B R

    1981-01-01

    To define the risks associated with central venous catheterization for total parenteral nutrition (TPN) 3291 patient days of this therapy, delivered by an established nutrition support team, were evaluated. One hundred and seventy-five catheters placed in 104 patients were reviewed over an 18 month period. Positive cultures were reported on 11 cannulae for a 6.4% incidence of colonization; five catheters (2.8%) were considered septic. Pleural or mediastinal complications of subclavian or internal jugular venipuncture occurred in eight patients (4.8%). Misdirection of the catheter tip occurred in 11.5% of insertions. Five patients (4.8%) had clinically apparent thrombosis in the superior vena cava, innominate and/or subclavian veins during hospitalization; four others had evidence of thrombosis at autopsy examination, giving an incidence of 8.7% in the entire series. No death directly resulted from the use of this therapy. Compliance with a rigid protocol by an experienced team can allow safe and effective use of central venous catheters and parenteral nutrition therapy. PMID:6782956

  11. Locating the optimal internal jugular target site for central venous line placement.

    PubMed

    Giordano, Chris R; Murtagh, Kevin R; Mills, Jaime; Deitte, Lori A; Rice, Mark J; Tighe, Patrick J

    2016-09-01

    Historically, the placement of internal jugular central venous lines has been accomplished by using external landmarks to help identify target-rich locations in order to steer clear of dangerous structures. This paradigm is largely being displaced, as ultrasound has become routine practice, raising new considerations regarding target locations and risk mitigation. Most human anatomy texts depict the internal jugular vein as a straight columnar structure that exits the cranial vault the same size that it enters the thoracic cavity. We dispute the notion that the internal jugulars are cylindrical columns that symmetrically descend into the thoracic cavity, and purport that they are asymmetric conical structures. The primary aim of this study was to evaluate 100 consecutive adult chest and neck computed tomography exams that were imaged at an inpatient hospital. We measured the internal jugular on the left and right sides at three different levels to look for differences in size as the internal jugular descends into the thoracic cavity. We revealed that as the internal jugular descends into the thorax, the area of the vessel increases and geometrically resembles a conical structure. We also reconfirmed that the left internal jugular is smaller than the right internal jugular. Understanding that the largest target area for central venous line placement is the lower portion of the right internal jugular vein will help to better target vascular access for central line placement. This is the first study the authors are aware of that depicts the internal jugular as a conical structure as opposed to the commonly depicted symmetrical columnar structure frequently illustrated in anatomy textbooks. This target area does come with additional risk, as the closer you get to the thoracic cavity, the greater the chances for lung injury. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Analysis of "dry" mesothelioma with ultrasound guided biopsies.

    PubMed

    Stigt, Jos A; Boers, James E; Groen, Harry J M

    2012-12-01

    Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. A concise history of central venous access.

    PubMed

    Beheshti, Michael V

    2011-12-01

    Central venous access has become a mainstay of modern interventional radiology practice. Its history has paralleled and enabled many current medical therapies. This short overview provides an interesting historical perspective of these increasingly common interventional procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Central line-associated venous late effects in children without prior history of thrombosis.

    PubMed

    Ruud, Ellen; Holmstrøm, Henrik; Hopp, Einar; Wesenberg, Finn

    2006-09-01

    The frequency of asymptomatic central line-associated thromboses is high and well recognized among children with cancer, while the long-term consequences are mainly unknown. In a cross-sectional study, we evaluated clinical and radiological venous outcome in children with previous long-standing intravascular catheters. The study enrolled 71 children previously treated for malignant or haematological diseases, 4-180 (median 37) mo after removal of their central lines. Inclusion criteria were a prior central line in a jugular vein for a minimum of 6 mo and no previous history of thrombosis. The children had clinical examination for post-thrombotic syndrome (PTS) and Doppler ultrasonography of the central neck veins. Twelve children had additional venous magnetic resonance imaging (MRI). But no kind of venography was performed in the remaining. We observed mild PTS with increased superficial collaterals in four children (6%), but no cases of more severe PTS. None complained of symptoms related to venous late effects. By ultrasonography, post-thrombotic venous alterations were detected in 17 children (24%), and five of these had complete occlusion of the veins. The sensitivity for pathologically increased collaterals to identify occlusive thrombosis was 0.6, while the specificity was 0.98. Occlusive venous thromboembolism was associated with the total number of central venous lines (CVLs; p=0.002), previous severe CVL-associated infections (p=0.001) and duration of central line in place (p=0.042). In spite of no prior history of thrombosis, children with previous long-term jugular lines frequently had local thrombotic sequelae, while clinical symptoms of PTS were rare.

  15. Is there a link between the structural impact of thoracic outlet and the development of central venous stenosis?

    PubMed

    Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji

    2013-01-01

    Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Performance of central venous catheterization by medical students: a retrospective study of students’ logbooks

    PubMed Central

    2014-01-01

    Background Medical students often learn the skills necessary to perform a central venous catheterization in the operating room after simulator training. We examined the performance of central venous catheterization by medical students from the logbooks during their rotation in department of anesthesiology. Methods From the logbooks of medical students rotating in our department between January 2011 and June 2012, we obtained the kind and the number of central venous catheterization students had done, the results of the procedures whether they were success or failed, the reasons of the failures, complications, and the student self-reported confidence and satisfaction of their performance. Results There were 93 medical students performed 875 central venous catheterizations with landmark guidance on patients in the operating theater, and the mean number of catheterizations performed per student was 9.4 ± 2.0, with a success rate of 67.3%. Adjusted for age, sex, body mass index, surgical category, ASA score and insertion site, the odds of successful catherization improved with cumulative practice (odds ratio 1.10 per additional central venous catheterization performed; 95% confidence interval 1.05–1.15). The major challenge students encountered during the procedure was the difficulty of finding the central veins, which led to 185 catheterizations failed. The complication rate of central venous catheterization by the students was 7.8%, while the most common complication was puncture of artery. The satisfaction and confidence of students regarding their performance increased with each additional procedure and decreased significantly if failure or complications had occurred. Conclusion A student logbook is a useful tool for recording the actual procedural performance of students. From the logbooks, we could see the students’ performance, challenges, satisfaction and confidence of central venous catheterization were improved through cumulative clinical practice of

  17. Cerebral venous circulatory system evaluation by ultrasonography.

    PubMed

    Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost

    2013-06-01

    Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.

  18. Ultrasound-Guided Treatment of Peripheral Nerve Pathology.

    PubMed

    Dettori, Nathan; Choudur, Hema; Chhabra, Avneesh

    2018-07-01

    High-resolution ultrasound serves as a fast, accessible, reliable, and radiation-free tool for anatomical and dynamic evaluation of various peripheral nerves. It can be used not only to identify and diagnose peripheral nerve and perineural pathology accurately but also to guide various nerve and perineural interventions. We describe the normal and pathologic appearances of peripheral nerves, the pathologies commonly affecting the individual peripheral nerves, and the current ultrasound-guided peripheral nerve interventions and techniques. Future directions are also highlighted. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teichgraeber, Ulf Karl-Martin, E-mail: ulf.teichgraeber@charite.de; Streitparth, Florian, E-mail: florian.streitparth@charite.d; Gebauer, Bernhard, E-mail: bernhard.gebauer@charite.d

    Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition whenmore » required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.« less

  20. Central Venous Catheter Insertion Site and Colonization in Pediatric Cardiac Surgery

    ClinicalTrials.gov

    2017-11-04

    Central Line-associated Bloodstream Infection (CLABSI); Central Venous Catheter Associated Bloodstream Infection; Heart; Surgery, Heart, Functional Disturbance as Result; Congenital Heart Disease; Newborn; Infection

  1. Venous Ulcers

    PubMed Central

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  2. Central venous catheter-associated bloodstream infections in a pediatric intensive care unit: effect of the location of catheter insertion.

    PubMed

    Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan

    2012-05-01

    To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.

  3. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    PubMed

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    PubMed

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-06-01

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p < 0.001]. No difference was seen in time to cannulate [SMD (95% CI) -0.31 (-0.65, 0.04); p = 0.30] and mean number of attempt [MD (95% CI) -0.65 (-1.32, 0.02); p = 0.06] between USG guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of

  5. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    PubMed Central

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  6. Ultrasound-guided interventional procedures around the shoulder.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria

    2016-01-01

    Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.

  7. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    PubMed

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  8. Ultrasound guided therapeutic injections of the cervical spine and brachial plexus.

    PubMed

    Cormick, Wes

    2014-02-01

    Introduction : Recent applications in ultrasound imaging include ultrasound assessment and ultrasound guided therapeutic injections of the spine and brachial plexus. Discussion : Ultrasound is an ideal modality for these regions as it allows accurate safe and quick injection of single or multiple sites. It has the added advantages of lack of ionising radiation, and can be done without requiring large expensive radiology equipment. Conclusion : Brachial plexus pathology may be present in patients presenting for shoulder symptoms where very little is found at imaging the shoulder. It is important to understand the anatomy and normal variants that may exist to be able to recognise when pathology is present. When pathology is demonstrated it is easy to do a trial of therapy with ultrasound guided injection of steroid around the nerve lesion. This review will outline the normal anatomy and variants and common pathology, which can be amenable to ultrasound guided injection of steroid.

  9. Ultrasound-guided central venous catheterization in cancer patients improves the success rate of cannulation and reduces mechanical complications: A prospective observational study of 1,978 consecutive catheterizations

    PubMed Central

    2010-01-01

    Background A central venous catheter (CVC) currently represents the most frequently adopted intravenous line for patients undergoing infusional chemotherapy and/or high-dose chemotherapy with hematopoietic stem-cell transplantation and parenteral nutrition. CVC insertion represents a risk for pneumothorax, nerve or arterial punctures. The aim of this prospective observational study was to explore the safety and efficacy of CVC insertion under ultrasound (US) guidance and to confirm its utility in clinical practice in cancer patients. Methods Consecutive adult patients attending the oncology-hematology department were eligible if they had solid or hematologic malignancies and required CVC insertion. Four types of possible complication were defined a priore: mechanical, thrombotic, infection and malfunctioning. The patient was placed in Trendelenburg's position, a 7.5 MHZ puncturing US probe was placed in the supraclavicular site and a 16-gauge needle was advanced under real-time US guidance into the last portion of internal jugular vein. The Seldinger technique was used to place the catheter, which was advanced into the superior vena cava until insertion into right atrium. Within two hours after each procedure, an upright chest X-ray and ultrasound scanning were carried out to confirm the CVC position and to rule out a pneumotorax. CVC-related infections, symptomatic vein thrombosis and malfunctioning were recorded. Results From December 2000 to January 2009, 1,978 CVC insertional procedures were applied to 1,660 consecutive patients. The procedure was performed 580 times in patients with hematologic malignancies and 1,398 times those with solid tumors. A single-needle puncture of the vein was performed on 1,948 of 1,978 procedures (98.48%); only eighteen attempts among 1,978 failed (0.9%). No pneumotorax, no major bleeding, and no nerve puncture were reported; four cases (0.2%) showed self-limiting hematomas. The mean lifespan of CVC was 189.7 +/- 18.6 days (range

  10. Central venous catheter infection-related glomerulonephritis under long-term parenteral nutrition: a report of two cases.

    PubMed

    Okada, Mari; Sato, Mai; Ogura, Masao; Kamei, Koichi; Matsuoka, Kentaro; Ito, Shuichi

    2016-03-31

    Advances in long-term parenteral nutrition via indwelling central venous catheter have improved the quality of life and mortality in patients with life-threatening gastrointestinal diseases complicated with severely impaired absorption. However, infection to central venous catheter is still a common and critical complication for such patients. We encountered two patients under long-term parenteral nutrition who developed glomerulonephritis associated with central venous catheter infection. Persistent bacterial infection in indwelling medical devices placed in the blood-stream such as a ventricular-atrial shunt is known to cause glomerulonephritis, a condition termed shunt nephritis. We reported the clinical manifestations, treatment and their pathological findings in the two patients with glomerulonephritis associated with central venous catheter infection. Both patients suffered from megacystis microcolon intestinal hypoperistalsis syndrome, a form of pseudo-Hirschsprung's disease. They had been receiving home parenteral nutrition via central venous catheter because of severe malabsorption. They presented proteinuria, hematuria, hypocomplementemia and positive PR3-antineutrophilic cytoplasmic antibody accompanied by Staphylococcus epidermidis infection in the central venous catheter. Their renal biopsy revealed membranoproliferative glomerulonephritis with positive C3 deposition. One of them recovered completely following the removal of catheter and administration of antibiotics, while another did not respond to the treatments. We then treated her with methylprednisolone pulse therapy followed by prednisolone. She responded well, and achieved complete remission. As central venous catheter infection-related glomerulonephritis has a similar etiology to shunt nephritis, removal of the catheter and administration of antibiotics is fundamental to the treatment. If a patient is resistant to such conventional therapy, additional steroid and/or immunosuppressive agent

  11. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    PubMed

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  12. Influence of central venous pressure upon sinus node responses to arterial baroreflex stimulation in man

    NASA Technical Reports Server (NTRS)

    Mark, A. L.; Takeshita, A.; Eckberg, D. L.; Abboud, F. M.

    1978-01-01

    Measurements were made of sinus node responses to arterial baroreceptor stimulation with phenylephrine injection or neck suction, before and during changes of central venous pressure provoked by lower body negative pressure or leg and lower truck elevation. Variations of central venous pressure between 1.1 and 9.0 mm Hg did not influence arterial baroreflex mediated bradycardia. Baroreflex sinus node responses were augmented by intravenous propranolol, but the level of responses after propranolol was comparable during the control state, lower body negative pressure, and leg and trunk elevation. Sinus node responses to very brief baroreceptor stimuli applied during the transitions of central venous pressure also were comparable in the three states. The authors conclude that physiological variations of central venous pressure do not influence sinus node responses to arterial baroreceptor stimulation in man.

  13. Central venous catheters: legal issues.

    PubMed

    Gallieni, Maurizio; Martina, Valentina; Rizzo, Maria Antonietta; Gravellone, Luciana; Mobilia, Francesca; Giordano, Antonino; Cusi, Daniele; Genovese, Umberto

    2011-01-01

    In dialysis patients, both central venous catheter (CVC) insertion and CVC use during the dialysis procedure pose important legal issues, because of potentially severe, even fatal, complications. The first issue is the decision of the kind of vascular access that should be proposed to patients: an arteriovenous (AV) fistula, a graft, or a CVC. The second issue, when choosing the CVC option, is the choice of CVC: nontunneled versus tunneled. Leaving a temporary nontunneled CVC for a prolonged time increases the risk of complications and could raise a liability issue. Even when choosing a long-term tunneled CVC, nephrologists should systematically explain its potential harms, presenting them as "unsafe for long-term use" unless there is a clear contraindication to an AV native or prosthetic access. Another critical issue is the preparation of a complete, informative, and easy-to-understand consent form. The CVC insertion procedure has many aspects of legal interest, including the choice of CVC, the use of ECG monitoring, the use of ultrasound guidance for cannulation, and the use of fluoroscopy for checking the position of the metal guidewire during the procedure as well as the CVC tip before the end of the procedure. Use of insertion devices and techniques that can prevent complications should obviously be encouraged. Complications of CVC use are mainly thrombosis and infection. These are theoretically expected as pure complications (and not as malpractice effects), but legal issues might relate to inappropriate catheter care (in both the inpatient and outpatient settings) rather than to the event per se. Thus, in the individual case it is indeed very difficult to establish malpractice and liability with a catheter-related infection or thrombosis. In conclusion, we cannot avoid complications completely when using CVCs, but reducing them to a minimum and adopting safe approaches to their insertion and use will reduce legal liability.

  14. Characterization of central venous catheter-associated deep venous thrombosis in infants.

    PubMed

    Gray, Brian W; Gonzalez, Raquel; Warrier, Kavita S; Stephens, Lauren A; Drongowski, Robert A; Pipe, Steven W; Mychaliska, George B

    2012-06-01

    Deep venous thrombosis (DVT) is a frequent complication in infants with central venous catheters (CVCs). We performed this study to identify risk factors and risk-reduction strategies of CVC-associated DVT in infants. Infants younger than 1 year who had a CVC placed at our center from 2005 to 2009 were reviewed. Patients with ultrasonically diagnosed DVT were compared to those without radiographic evidence. Of 333 patients, 47% (155/333) had femoral, 33% (111/333) had jugular, and 19% (64/333) had subclavian CVCs. Deep venous thromboses occurred in 18% (60/333) of patients. Sixty percent (36/60) of DVTs were in femoral veins. Femoral CVCs were associated with greater DVT rates (27%; 42/155) than jugular (11%; 12/111) or subclavian CVCs (9%; 6/64; P < .01). There was a 16% DVT rate in those with saphenofemoral Broviac CVCs vs 83% (20/24) in those with percutaneous femoral lines (P < .01). Multilumen CVCs had higher DVT rates than did single-lumen CVCs (54% vs 6%, P < .01), and mean catheter days before DVT diagnosis was shorter for percutaneous lines than Broviacs (13 ± 17 days vs 30 ± 37 days, P = .02). Patients with +DVT had longer length of stay (86 ± 88 days vs 48 ± 48 days, P < .01) and higher percentage of intensive care unit admission (82% vs 70%, P = .02). Deep venous thrombosis reduction strategies in infants with CVCs include avoiding percutaneous femoral and multilumen CVCs, screening percutaneous lines, and early catheter removal. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography

    PubMed Central

    Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.

    2014-01-01

    Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257

  16. Pinch-off syndrome: transection of implantable central venous access device.

    PubMed

    Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu

    2012-11-30

    As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take chemotherapy because the device occluded. Further examination revealed the transection of the catheter. The transected fragment of the catheter in the heart was successfully removed by using a loop snare placed through the right femoral vein.

  17. A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation

    PubMed Central

    Sarach, Janine; Zschokke, Irin; Melcher, Gian A.

    2015-01-01

    Patient: Female, 68 Final Diagnosis: Mediastinal hematoma Symptoms: Agitation • severe hemodynamic instability • severe respiratory distress Medication: — Clinical Procedure: Cardiopulmonary resuscitation • reintubation • thoracic drain Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava. Case Report: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection. Conclusions: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to

  18. Comparison of Two Devices for Intraoperative Portal Venous Flow Measurement in Living-Donor Liver Transplantation: Transit Time Ultrasound and Conventional Doppler Ultrasound.

    PubMed

    Wang, H-K; Chen, C-Y; Lin, N-C; Liu, C-S; Loong, C-C; Lin, Y-H; Lai, Y-C; Chiou, H-J

    2018-05-01

    Intraoperative portal venous flow measurement provides surgeons with instant guidance for portal flow modulation during living-donor liver transplantation (LDLT). In this study, we compared the agreement of portal flow measurement obtained by 2 devices: transit time ultrasound (TTU) and conventional Doppler ultrasound (CDU). Fifty-four recipients of LDLT underwent intraoperative measurement of portal flow after completion of vascular anastomosis of the implanted partial liver graft. Both TTU and CDU were used concurrently. Agreement of TTU and CDU was assessed by intraclass correlation coefficient using a model of 2-way random effects, absolute agreement, and single measurement. A Bland-Altman plot was applied to assess the variability between the 2 devices. The mean, median, and range of portal venous flow was 1456, 1418, and 117 to 2776 mL/min according to TTU; and 1564, 1566, and 119 to 3216 mL/min according to CDU. The intraclass correlation coefficient of portal venous flow between TTU and CDU was 0.68 (95% confidence interval, 0.51-0.80). The Bland-Altman plots revealed an average variation of 4.8% between TTU and CDU but with a rather wide 95% confidence interval of variation ranging from -57.7% to 67.4%. Intraoperative TTU and CDU showed moderate agreement in portal flow measurement. However, a relatively wide range of variation exists between TTU and CDU, indicating that data obtained from the 2 devices may not be interchangeable. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. EFFECTS OF LOW-FREQUENCY ULTRASOUND ON MICROCIRCULATION IN VENOUS LEG ULCERS

    PubMed Central

    Wollina, Uwe; Heinig, Birgit; Naumann, Gunther; Scheibe, Armin; Schmidt, Wolf-Dieter; Neugebauer, Reimund

    2011-01-01

    Background: Therapeutic low-frequency ultrasound (US) has been used for many years to improve wound healing in chronic wounds like venous leg ulcers. No human data are available for the possible effects of single US applications on microcirculation and their frequency-dependency. Aims: To investigated the role of therapeutic low-frequency US on microcirculation of venous leg ulcers in vivo. Patients and Methods: This is a pilot study on an inpatient basis. We use a newly developed low-frequency continuous-wave US-equipment composed of a US transducer based on piezo-fiber composites that allow the change of frequency. In this study, we apply US of 34 kHz, 53.5 kHz, and 75 kHz respectively. Twelve patients with chronic venous leg ulcers are analyzed. As an adjunct to good ulcer care, therapeutic US is applied, non-contacting, once a day, in a subaqual position for 10 minutes. Microcirculation is assessed in the ulcers adjacent to skin before US-therapy, immediately after the treatment and 30 minutes later. We use a micro-light guide spectrophotometer (O2C, LEA Medizintechnik GmbH, Gieίen, Germany) for calculation of blood flow velocity, hemoglobin oxygen saturation (SCO2) and relative hemoglobin concentration (rHb) in 2 and 8 mm depth. Contact-free remission spectroscopy (SkinREM3, Color Control Chemnitz GmbH, Chemnitz, Germany) allows contact free measurements in the VIS-NIR range of the spectrum (400 ± 1600 nm). Results: It is seen that therapeutic US is well tolerated. One patient dropped out from a treatment series since he developed erysipelas responding to standard antibiotic. Effects were seen at 34 kHz only. The SO2 values increased after single US application. The values for rHb were higher in the superficial layer of the wound bed (depth 2 mm) compared to deeper parts (8 mm depth). US treatment did not result in significant changes of rHb and blood cell velocity. The data obtained by remission spectroscopy disclose an increase of oxygenized hemoglobin

  20. [Efficacy and safety of ultrasound-guided or neurostimulator-guided bilateral axillary brachial plexus block].

    PubMed

    Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G

    2017-10-17

    Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P <0.01). The performance pain score of group N was (25.5± 13.2), which was obviously more serious than group U (31.7± 11.2) and a significant statistical difference was detected ( t =2.856, P <0.05). The patient satisfaction degree of group U was 95.0%, which was significantly higher than group N (83.3%) and a markedly statistical difference was detected (χ(2)=4.227, P <0.05). Fifty min after performance, the total plasma concentration of ropivacaine of group U was(1.76±0.48)mg/L, which was significantly lower than group N (1.88±0.53)mg/L and a significant statistical difference was detected ( t =2.43, P <0.05), while no significant differences were detected at the

  1. Central venous recanalization in patients with short gut syndrome: restoration of candidacy for intestinal and multivisceral transplantation.

    PubMed

    Lang, Elvira V; Reyes, Jorge; Faintuch, Salomao; Smith, Amy; Abu-Elmagd, Kareem

    2005-09-01

    To assess feasibility and success of venous recanalization in patients with short gut syndrome who have lost their traditional central venous access and required intestinal or multivisceral transplantation. Twelve patients between the ages of 7 and 55 years with short gut syndrome and long-standing total parenteral nutrition (TPN) dependency and/or hypercoagulability were treated. All had extensive chronic central venous occlusions and survival was dependent on restoration of access and planned transplantation. Central venous recanalizations were obtained via sharp needle recanalization techniques, venous reconstructions with stents, and/or extraanatomic access to the central venous system for placement of central venous tunneled catheters. Central venous access was restored in all patients without operative-related mortality. Three major hemodynamic perioperative technical complications were recorded and successfully treated. There were three self-limited early infectious complications. With a mean follow-up of 22 months, eight of the 12 patients were alive with successful small bowel or multivisceral transplantation; six of those became independent of TPN. The remaining four patients died of complications related to TPN (n = 3) or transplantation (n = 1). With a mean follow-up of 20 months, all but two of the recanalized venous accesses were maintained, for a success rate of 83%. Recanalizations of extensive chronic vein occlusions are feasible but associated with high risk. The technique is life-saving for TPN-dependent patients and can restore candidacy for intestinal and multivisceral transplantation. This approach is likely to be increasingly requested because of the current clinical availability of the transplant procedure.

  2. High-intensity focused ultrasound (HIFU) array system for image-guided ablative therapy (IGAT)

    NASA Astrophysics Data System (ADS)

    Kaczkowski, Peter J.; Keilman, George W.; Cunitz, Bryan W.; Martin, Roy W.; Vaezy, Shahram; Crum, Lawrence A.

    2003-06-01

    Recent interest in using High Intensity Focused Ultrasound (HIFU) for surgical applications such as hemostasis and tissue necrosis has stimulated the development of image-guided systems for non-invasive HIFU therapy. Seeking an all-ultrasound therapeutic modality, we have developed a clinical HIFU system comprising an integrated applicator that permits precisely registered HIFU therapy delivery and high quality ultrasound imaging using two separate arrays, a multi-channel signal generator and RF amplifier system, and a software program that provides the clinician with a graphical overlay of the ultrasound image and therapeutic protocol controls. Electronic phasing of a 32 element 2 MHz HIFU annular array allows adjusting the focus within the range of about 4 to 12 cm from the face. A central opening in the HIFU transducer permits mounting a commercial medical imaging scanhead (ATL P7-4) that is held in place within a special housing. This mechanical fixture ensures precise coaxial registration between the HIFU transducer and the image plane of the imaging probe. Recent enhancements include development of an acoustic lens using numerical simulations for use with a 5-element array. Our image-guided therapy system is very flexible and enables exploration of a variety of new HIFU therapy delivery and monitoring approaches in the search for safe, effective, and efficient treatment protocols.

  3. First noninvasive thermal ablation of a brain tumor with MR-guided focused ultrasound

    PubMed Central

    2014-01-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas its clinical application for tumor neurosurgery has been delayed for various technical and procedural reasons. Here, we report the case of a 63-year-old patient presenting with a centrally located recurrent glioblastoma who was included in our ongoing clinical phase I study aimed at evaluating the feasibility and safety of transcranial MRgFUS for brain tumor ablation. Applying 25 high-power sonications under MR imaging guidance, partial tumor ablation could be achieved without provoking neurological deficits or other adverse effects in the patient. This proves, for the first time, the feasibility of using transcranial MR-guided focused ultrasound to safely ablate substantial volumes of brain tumor tissue. PMID:25671132

  4. Central Vein Dilatation Prior to Concomitant Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krombach, Gabriele A., E-mail: krombach@rad.rwth-aachen.de; Plumhans, Cedric; Goerg, Fabian

    2010-04-15

    Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker andmore » occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.« less

  5. The Use of Ultrasound to Improve Axillary Vein Access and Minimize Complications during Pacemaker Implantation.

    PubMed

    Esmaiel, Abdullah; Hassan, Jeremy; Blenkhorn, Fay; Mardigyan, Vartan

    2016-05-01

    The Agency for Healthcare Research and Quality in the United States recommends the use of ultrasound (US) for central venous access to improve patient outcomes. However, in a recent publication, US is still underutilized for axillary vein access during pacemaker implantation. We sought to describe a technique for US-guided axillary vein access during pacemaker implantation and to report complication rates and success rate. Retrospective data collection included success rate and complications on all pacemaker implants by one operator since implementing the systematic use of US at our institution, from November 2012 to January 2015. For the last 59 cases, data were collected prospectively to include time of venous access and number of attempts. A total of 403 consecutive patients were included in the analysis. Two leads were implanted in 255 cases and one lead was implanted in 148 cases. The rate of successful US-guided access was 99.25%. There were no access-related complications. The average number of venipuncture attempts was 1.18 per patient. The average time to obtain venous access was 2.24 minutes including the time to apply the sterile US sleeve. The described technique has the potential to improve the success rate of axillary vein access and minimize complications during pacemaker implantation. ©2016 Wiley Periodicals, Inc.

  6. Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.

    PubMed

    Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs

    2012-08-01

    Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.

  7. Ultrasound-guided supraclavicular block: outcome of 510 consecutive cases.

    PubMed

    Perlas, Anahi; Lobo, Giovanni; Lo, Nick; Brull, Richard; Chan, Vincent W S; Karkhanis, Reena

    2009-01-01

    Supraclavicular brachial plexus block provides consistently effective anesthesia to the upper extremity. However, traditional nerve localization techniques may be associated with a high risk of pneumothorax. In the present study, we report block success and clinical outcome data from 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery. After institutional review board approval, the outcome of 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery was reviewed. Real-time ultrasound guidance was used with a high-frequency linear probe. The neurovascular structures were imaged on short axis, and the needle was inserted using an in-plane technique with either a medial-to-lateral or lateral-to-medial orientation. Five hundred ten ultrasound-guided supraclavicular blocks were performed (50 inpatients, 460 outpatients) by 47 different operators at different levels of training over a 24-month period. Successful surgical anesthesia was achieved in 94.6% of patients after a single attempt; 2.8% required local anesthetic supplementation of a single peripheral nerve territory; and 2.6% received an unplanned general anesthetic. No cases of clinically symptomatic pneumothorax developed. Complications included symptomatic hemidiaphragmatic paresis (1%), Horner syndrome (1%), unintended vascular punctures (0.4%), and transient sensory deficits (0.4%). Ultrasound-guided supraclavicular block is associated with a high rate of successful surgical anesthesia and a low rate of complications and thus may be a safe alternative for both inpatients and outpatients. Severe underlying respiratory disease and coagulopathy should remain a contraindication for this brachial plexus approach.

  8. Laser Recanalization of Central Venous Occlusion to Salvage a Threatened Arteriovenous Fistula.

    PubMed

    Rambhia, Sagar; Janko, Matthew; Hacker, Robert I

    2018-07-01

    Central venous occlusion is conventionally managed with balloon angioplasty, stent extension, or sharp recanalization. Here, we describe recanalization of a chronically occluded innominate vein using excimer laser after conventional techniques were unsuccessful. Patient clinical improvement and fistula patency have been sustained 2 years postintervention. This technique may provide new hemodialysis access options for patients who would not otherwise be candidates for hemodialysis access on the ipsilateral side of a central venous occlusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Prospective comparison of two management strategies of central venous catheters in burn patients.

    PubMed

    Kealey, G P; Chang, P; Heinle, J; Rosenquist, M D; Lewis, R W

    1995-03-01

    Central venous catheters (CVCs) are associated with sepsis in burn patients. This study was undertaken to compare two strategies of CVC management in patients with major burn injuries. Forty-two burn patients with major burn injuries were randomly assigned to undergo site change every 48 hours of the CVC or to undergo wire guide exchange of the CVC every 48 hours at the same site. Catheter insertion site, distance from the burn wound, cultures of catheter tips, and blood cultures were obtained from all patients in a prospective manner. There was no difference in the incidence of CVC sepsis between the two groups studied. CVCs inserted less than 5 cm from the burn wound developed bacterial contamination at an earlier time than CVCs inserted more than 5 cm from the burn wound. There was no advantage to changing the CVC insertion site every 48 hours. Changing the CVC using the wire guide technique did not prevent, nor predict, CVC bacterial contamination.

  10. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  11. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  12. Ultrasound image-guided therapy enhances antitumor effect of cisplatin.

    PubMed

    Sasaki, Noboru; Kudo, Nobuki; Nakamura, Kensuke; Lim, Sue Yee; Murakami, Masahiro; Kumara, W R Bandula; Tamura, Yu; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2014-01-01

    The aim of this study was to clarify whether ultrasound image-guided cisplatin delivery with an intratumor microbubble injection enhances the antitumor effect in a xenograft mouse model. Canine thyroid adenocarcinoma cells were used for all experiments. Before in vivo experiments, the cisplatin and microbubble concentration and ultrasound exposure time were optimized in vitro. For in vivo experiments, cells were implanted into the back of nude mice. Observed by a diagnostic ultrasound machine, a mixture of cisplatin and ultrasound contrast agent, Sonazoid, microbubbles was injected directly into tumors. The amount of injected cisplatin and microbubbles was 1 μg/tumor and 1.2 × 10(7) microbubbles/tumor, respectively, with a total injected volume of 20 μl. Using the same diagnostic machine, tumors were exposed to ultrasound for 15 s. The treatment was repeated four times. The combination of cisplatin, microbubbles, and ultrasound significantly delayed tumor growth as compared with no treatment (after 18 days, 157 ± 55 vs. 398 ± 49 mm(3), P = 0.049). Neither cisplatin alone nor the combination of cisplatin and ultrasound delayed tumor growth. The treatment did not decrease the body weight of mice. Ultrasound image-guided anticancer drug delivery may enhance the antitumor effects of drugs without obvious side effects.

  13. Pregnancies following ultrasound-guided drainage of tubo-ovarian abscess.

    PubMed

    Gjelland, Knut; Granberg, Seth; Kiserud, Torvid; Wentzel-Larsen, Tore; Ekerhovd, Erling

    2012-07-01

    To study fertility among women treated by means of ultrasound-guided drainage and antibiotics for tubo-ovarian abscess (TOA). Retrospective cohort study. A tertiary referral center. One hundred women of reproductive age treated for TOA between June 1986 and July 2003. Transvaginal ultrasound-guided drainage of TOA was performed in all patients. The procedure was repeated if a substantial amount of pus was seen using ultrasonography 2-5 days after the initial aspiration, and repeated later if necessary. Frequency of naturally conceived pregnancies. Twenty of 38 (52.6%; 95% CI 36.5-68.9%) women who intended to have a child achieved pregnancy naturally and became mothers. In addition, 7 (50%) of 14 women who were not on birth control on a regular basis became pregnant. No ectopic pregnancies were registered. Ultrasound-guided drainage of TOA in combination with antibiotics seems to preserve fertility in approximately half of the patients. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  14. Transurethral ultrasound-guided laser-induced prostatectomy

    NASA Astrophysics Data System (ADS)

    Babayan, Richard K.; Roth, Robert A.

    1991-07-01

    A transurethral ultrasound-guided Nd:YAG laser delivery system has been developed for use as an alternative approach to the treatment of benign prostatic hyperplasia. The TULIP system has been extensively tested in canine models and is currently undergoing FDA trials in humans.

  15. Focused ultrasound guided relocation of kidney stones.

    PubMed

    Abrol, Nitin; Kekre, Nitin S

    2015-01-01

    Complete removal of all fragments is the goal of any intervention for urinary stones. This is more important in lower pole stones where gravity and spatial orientation of lower pole infundibulum may hinder spontaneous passage of fragments. Various adjuvant therapies (inversion, diuresis, percussion, oral citrate, etc.) are described to enhance stone-free rate but are not widely accepted. Focused ultrasound-guided relocation of fragments is a recently described technique aimed at improving results of intervention for stone disease. Purpose of this review is to discuss development of this technology and its potential clinical applications. Pubmed search was made using key words "Focused ultrasound" and "kidney stone". All English language articles were reviewed by title. Relevant studies describing development and application of focused ultrasound in renal stones were selected for review. Focused ultrasound has proven its efficacy in successfully relocating up to 8 mm stone fragments in vitro and in pigs. Relocation is independent of stone composition. The latest model allows imaging and therapy with a single handheld probe facilitating its use by single operator. The acoustic energy delivered by the new prototype is even less than that used for extracorporeal shock wave lithotripsy. Therapeutic exposure has not caused thermal injury in pig kidneys. Focused ultrasound-guided relocation of stones is feasible. Though it is safe in application in pigs, technology is awaiting approval for clinical testing in human beings. This technology has many potential clinical applications in the management of stone disease.

  16. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    PubMed Central

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  17. Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.

    PubMed

    Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K

    2015-02-01

    We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.

  18. [Port device central venous access in children with chronic renal disease--personal experience].

    PubMed

    Szczepańska, Maria; Szprynger, Krystyna; Stoksik, Piotr; Morawiec-Knysak, Aurelia; Adamczyk, Piotr; Ziora, Katarzyna; Oswiecimska, Joanna

    2006-01-01

    The application of central venous lines in children has been widely accepted in the case of pediatric cancer treatment. This is of particular importance when the treatment must be continued during the long period of time. The indication to long-term application of central venous lines became significantly frequent within last years. They are necessary in the treatment of chronic pediatric patients, in whom the central venous line allows continuous access for medication, parenteral rehydration, nutrition and frequent blood sampling. In the current study authors present their experience in subcutaneous port devices application in children with kidney disease. The case history data obtained from 8 children were retrospectively analysed. In these children subcutaneous port devices were applied for mean 26.7 months (totally 9 port devices). The mean age at the time of implantation was 2.2 years, and the mean body weight--10.6 kg. Peripheral venous access in all children was bad. In one child during the time of implantation the hematoma of coli and chest was present. Infectious complications connected with implanted port device were not detected. Thrombotic complications were present in 6 children with chronic renal failure--in 5 the lumen of port device has been successfully recanalysed, in 3 cases even several times. In 1 child the thrombus on the tip of central venous line was detected. In 2 children the removal of port device was necessary because of breakage of venous line and in the second case because of port device thrombosis. Two children died with functioning port device. The cause of death was not connected with implanted port device. The application of subcutaneous port devices definitely improved the comfort of treatment but was significantly associated with thrombotic complications. Infectious complications were not detected as compared to hematological group of patients.

  19. Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters

    DTIC Science & Technology

    2015-12-01

    1 AD_________________ AWARD NUMBER: W81XWH-08-2-0162 TITLE: Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War...Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters 5a. CONTRACT NUMBER 5b. GRANT NUMBER: W81XWH-08-2-0162 5c...Purpose: To demonstrate that 1) ultrasound guided foreign body removal (USFBR) is superior to conventional surgery in the cadaver model, 2) USFBR can be

  20. Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.

    PubMed

    Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J

    2010-09-01

    Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.

  1. Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.

    PubMed

    Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A

    2010-02-01

    Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.

  2. Knowledge of nursing students about central venous catheters.

    PubMed

    Mlinar, Suzana; Malnarsić, Rosanda Rasković

    2012-04-01

    Central venous catheters (CVC) are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC), dressing the catheter entry point, the reasons for measuring central venous pressure (CVP), possible complications and risk factors for developing infections related to CVC. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.

  3. [Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].

    PubMed

    Conz, P A; Malagoli, A; Normanno, M; Munaro, D

    2007-01-01

    A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.

  4. Prevalence and Risk Factors of Central Venous Stenosis among Prevalent Hemodialysis Patients, a Single Center Experience.

    PubMed

    Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra

    2014-01-01

    Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.

  5. Risk factors for upper extremity venous thrombosis associated with peripherally inserted central venous catheters.

    PubMed

    Marnejon, Thomas; Angelo, Debra; Abu Abdou, Ahmed; Gemmel, David

    2012-01-01

    To identify clinically important risk factors associated with upper extremity venous thrombosis following peripherally inserted central venous catheters (PICC). A retrospective case control study of 400 consecutive patients with and without upper extremity venous thrombosis post-PICC insertion was performed. Patient data included demographics, body mass index (BMI), ethnicity, site of insertion, size and lumen of catheter, internal length, infusate, and co-morbidities, such as diabetes mellitus, congestive heart failure, and renal failure. Additional risk factors analyzed were active cancer, any history of cancer, recent trauma, smoking, a history of prior deep vein thrombosis, and recent surgery, defined as surgery within three months prior to PICC insertion. The prevalence of trauma, renal failure, and infusion with antibiotics and total parenteral nutrition (TPN) was higher among patients exhibiting upper extremity venous thrombosis (UEVT), when compared to controls. Patients developing UEVT were also more likely to have PICC line placement in a basilic vein and less likely to have brachial vein placement (P<.001). Left-sided PICC line sites also posed a greater risk (P=.026). The rate of standard DVT prophylaxis with low molecular weight heparin and unfractionated heparin and the use of warfarin was similar in both groups. Average length of hospital stay was almost double among patients developing UEVT, 19.5 days, when compared to patients undergoing PICC line insertion without thrombosis, 10.8 days (t=6.98, P<.001). In multivariate analysis, trauma, renal failure, left-sided catheters, basilic placement, TPN, and infusion with antibiotics, specifically vancomycin, were significant risk factors for UEVT associated with PICC insertion. Prophylaxis with low molecular weight heparin, unfractionated heparin or use of warfarin did not prevent the development of venous thrombosis in patients with PICCs. Length of hospital stay and cost are markedly increased in

  6. It all unraveled from there: case report of a central venous catheter guidewire unraveling.

    PubMed

    Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc

    2014-12-01

    Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    PubMed

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  8. Placement of Upper Extremity Arteriovenous Access in Patients with Central Venous Occlusions: A Novel Technique.

    PubMed

    Murga, Allen G; Chiriano, Jason T; Bianchi, Christian; Sheng, Neha; Patel, Sheela; Abou-Zamzam, Ahmed M; Teruya, Theodore H

    2017-07-01

    Central venous occlusion is a common occurrence in patients with end-stage renal disease. Placement of upper extremity arteriovenous access in patients with occlusion of the brachiocephalic veins is often not an option. Avoidance of lower extremity vascular access can decrease morbidity and infection. The central venous lesions were crossed centrally via femoral access. The wire was retrieved in the neck extravascularly. A Hemodialysis Reliable Outflow catheter was then placed in the right atrium and completed with an arterial anastomosis. We describe a novel technique for placing upper extremity arteriovenous access in patients with occlusion of the brachiocephalic veins. This technique was utilized in 3 patients. The technical success was 100%. The placement of upper extremity arteriovenous access in patients with central venous occlusions is technically feasible. Published by Elsevier Inc.

  9. Endovascular treatment of central venous stenosis and obstruction in hemodialysis patients.

    PubMed

    Shi, Ya-xue; Ye, Meng; Liang, Wei; Zhang, Hao; Zhao, Yi-ping; Zhang, Ji-wei

    2013-02-01

    Central venous stenosis and obstruction (CVD) is a serious and prevalent challenge to both resolve the venous hypertension symptoms and maintain the pantency of the ipsilateral hemodialysis access in hemodialysis patients. This study aimed to summarize our experience of the endovascular management of the central venous stenosis or obstruction in hemodialysis patients. Twenty-four haemodialysis cases of central vein stenosis or obstruction with ipsilateral functional vascular access in our hospital between July 2006 and February 2012 were treated by interventional therapy and the data were analyzed retrospectively. Eighteen males and six females with mean age of (66.4 ± 13.8) years and manifesting with arm swelling and venous hypertension were enrolled; 62.5% of them had a history of catheterization. Venography showed stenotic lesion in 10 cases including eight cases of brachiocephalic vein stenosis and two cases of subclavian vein stenosis and 14 cases of obstruction lesions including seven cases of short brachiocephalic obstruction and seven cases of long segment obstruction. Interventional therapy was performed and the technique success rate was 83.3%. Percutaneous transluminal angioplasty (PTA) was performed in nine cases and stent was performed in 11 cases firstly. The symptoms of venous hypertension were resolved after intervention in all the cases. There was no major complication and death perioperatively. During follow-up, reintervention was done, the primary patency rates were (88.9 ± 10.5)%, (64.8 ± 10.5)% and (48.6 ± 18.7)% at 3 months, 6 months and 1 year after treatment in the PTA group; (90.0 ± 9.5)% and (77.1 ± 14.4)% at 6 months and 1 year after treatment in the stent group, respectively. The secondary patency rates were (48.6 ± 18.7)% in the PTA group and (83.3 ± 15.2)% in the stent group 1 year after treatment, respectively. There was no significant difference between the two groups (primary patency, P = 0.20; secondary patency, P = 0

  10. Photoacoustic-guided ultrasound therapy with a dual-mode ultrasound array

    NASA Astrophysics Data System (ADS)

    Prost, Amaury; Funke, Arik; Tanter, Mickaël; Aubry, Jean-François; Bossy, Emmanuel

    2012-06-01

    Photoacoustics has recently been proposed as a potential method to guide and/or monitor therapy based on high-intensity focused ultrasound (HIFU). We experimentally demonstrate the creation of a HIFU lesion at the location of an optical absorber, by use of photoacoustic signals emitted by the absorber detected on a dual mode transducer array. To do so, a dedicated ultrasound array intended to both detect photoacoustic waves and emit HIFU with the same elements was used. Such a dual-mode array provides automatically coregistered reference frames for photoacoustic detection and HIFU emission, a highly desired feature for methods involving guidance or monitoring of HIFU by use of photoacoustics. The prototype is first characterized in terms of both photoacoustic and HIFU performances. The probe is then used to perform an idealized scenario of photoacoustic-guided therapy, where photoacoustic signals generated by an absorbing thread embedded in a piece of chicken breast are used to automatically refocus a HIFU beam with a time-reversal mirror and necrose the tissue at the location of the absorber.

  11. 3D ultrasound imaging in image-guided intervention.

    PubMed

    Fenster, Aaron; Bax, Jeff; Neshat, Hamid; Cool, Derek; Kakani, Nirmal; Romagnoli, Cesare

    2014-01-01

    Ultrasound imaging is used extensively in diagnosis and image-guidance for interventions of human diseases. However, conventional 2D ultrasound suffers from limitations since it can only provide 2D images of 3-dimensional structures in the body. Thus, measurement of organ size is variable, and guidance of interventions is limited, as the physician is required to mentally reconstruct the 3-dimensional anatomy using 2D views. Over the past 20 years, a number of 3-dimensional ultrasound imaging approaches have been developed. We have developed an approach that is based on a mechanical mechanism to move any conventional ultrasound transducer while 2D images are collected rapidly and reconstructed into a 3D image. In this presentation, 3D ultrasound imaging approaches will be described for use in image-guided interventions.

  12. Fast Track ultrasound protocol to detect acute complications after totally implantable venous access device placement.

    PubMed

    Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng

    2015-01-01

    The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.

  13. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less

  14. Image-guided endobronchial ultrasound

    NASA Astrophysics Data System (ADS)

    Higgins, William E.; Zang, Xiaonan; Cheirsilp, Ronnarit; Byrnes, Patrick; Kuhlengel, Trevor; Bascom, Rebecca; Toth, Jennifer

    2016-03-01

    Endobronchial ultrasound (EBUS) is now recommended as a standard procedure for in vivo verification of extraluminal diagnostic sites during cancer-staging bronchoscopy. Yet, physicians vary considerably in their skills at using EBUS effectively. Regarding existing bronchoscopy guidance systems, studies have shown their effectiveness in the lung-cancer management process. With such a system, a patient's X-ray computed tomography (CT) scan is used to plan a procedure to regions of interest (ROIs). This plan is then used during follow-on guided bronchoscopy. Recent clinical guidelines for lung cancer, however, also dictate using positron emission tomography (PET) imaging for identifying suspicious ROIs and aiding in the cancer-staging process. While researchers have attempted to use guided bronchoscopy systems in tandem with PET imaging and EBUS, no true EBUS-centric guidance system exists. We now propose a full multimodal image-based methodology for guiding EBUS. The complete methodology involves two components: 1) a procedure planning protocol that gives bronchoscope movements appropriate for live EBUS positioning; and 2) a guidance strategy and associated system graphical user interface (GUI) designed for image-guided EBUS. We present results demonstrating the operation of the system.

  15. Ultrasound-guided percutaneous injection of methylene blue to identify nerve pathology and guide surgery.

    PubMed

    Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel

    2015-09-01

    OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.

  16. Update on Clinical MR-guided Focused Ultrasound Applications

    PubMed Central

    McDannold, Nathan

    2015-01-01

    SYNOPSIS Focused ultrasound (FUS) can be used to thermally ablate tissue. The performance of FUS under magnetic resonance (MR) guidance enables aiming the focus at the target, accurate treatment planning, real-time temperature mapping, and evaluation of the treatment. This review updates several clinical applications of MR-guided FUS. MR-guided FUS has a CE mark and FDA approval for thermal ablation for uterine fibroids and bone metastases related pain management. Thousands of uterine fibroid patients have successfully been treated with minor side effects. Technical improvements, increased experience, and the use of a screening MRI examination should further improve treatment outcome. When used for bone metastases and other bone diseases, thermal ablation leads to pain relief due to denervation, and debulking of the tumor. The use of a hemi-spherical multi-element transducer and phase corrections have enabled application of FUS through the skull. Transcranial MR-guided FUS has received CE certification for ablation of deep, central locations in the brain such as the thalamus. Thermal ablation of specific parts of the thalamus can result in relief of the symptoms in neurological disorders such as essential tremor, Parkinson’s, and neuropathic pain. No CE mark or FDA approval has been obtained as yet for treatment of prostate cancer or breast cancer, but several approaches have been proposed and clinical trials should show the potential of MR-guided FUS for these and other applications. PMID:26499282

  17. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion PRINCIPAL...Sep 2014 - 28 Sep 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Guided Interventions for Prostate Cancer Using 3D- Transurethral Ultrasound and...Magnetic Resonance- Ultrasound (MR-US) fusion allows for specific targeting of the tumors in real-time during clinical interventions, outside of an MR

  18. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    PubMed

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  19. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  20. Percutaneous retrieval of centrally embolized fragments of central venous access devices or knotted Swan-Ganz catheters. Clinical report of 14 retrievals with detailed angiographic analysis and review of procedural aspects

    PubMed Central

    Chmielak, Zbigniew; Dębski, Artur; Kępka, Cezary; Rudziński, Piotr N.; Bujak, Sebastian; Skwarek, Mirosław; Kurowski, Andrzej; Dzielińska, Zofia; Demkow, Marcin

    2016-01-01

    Introduction Totally implantable venous access systems (TIVAS), Swan-Ganz (SG) and central venous catheters (CVC) allow easy and repetitive entry to the central cardiovascular system. Fragments of them may be released inadvertently into the cardiovascular system during their insertion or as a result of mechanical complications encountered during long-term utilization. Aim To present results of percutaneous retrieval of embolized fragments of central venous devices or knotted SG and review the procedural aspects with a series of detailed angiographies. Material and methods Between January 2003 and December 2012 there were 14 (~0.025%) successful retrievals in 13 patients (44 ±16 years, 15% females) of embolized fragments of TIVAS (n = 10) or CVC (n = 1) or of dislodged guide-wires (n = 2) or knotted SG (n = 1). Results Foreign bodies with the forward end located in the right ventricle (RV), as well as those found in the pulmonary artery (PA), often required repositioning with a pigtail catheter as compared to those catheter fragments which were located in the right atrium (RA) and/or great vein and possessed an accessible free end allowing their direct ensnarement with the loop snare (57.0% (4/7) vs. 66.7% (2/3) vs. 0.0% (0/3); p = 0.074 respectively). Procedure duration was 2–3 times longer among catheters retrieved from the PA than among those with the forward edge located in the RV or RA (30 (18–68) vs. 13.5 (11–37) vs. 8 min (8–13); p = 0.054 respectively). The SG catheter knotted in the vena cava superior (VCS) was encircled with the loop snare introduced transfemorally, subsequently cut at its skin entrance and then pulled down inside the 14 Fr vascular sheath. Conclusions By using the pigtail catheter and the loop snare, it is feasible to retrieve centrally embolized fragments or knotted central venous access devices. PMID:27279874

  1. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    PubMed

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.

    PubMed

    Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N

    2015-01-01

    The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.

  3. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    PubMed

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  5. Venous Ultrasound (Extremities)

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... by a computer, which in turn creates a real-time picture on the monitor. One or more frames ...

  6. X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?

    PubMed Central

    Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas

    2017-01-01

    OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776

  7. Transoesophageal echocardiographic evaluation of central venous catheter positioning using Peres' formula or a radiological landmark-based approach: a prospective randomized single-centre study.

    PubMed

    Ahn, J H; Kim, I S; Yang, J H; Lee, I G; Seo, D H; Kim, S P

    2017-02-01

    The lower superior vena cava (SVC), near its junction with the right atrium (RA), is considered the ideal location for the central venous catheter tip to ensure proper function and prevent injuries. We determined catheter insertion depth with a new formula using the sternoclavicular joint and the carina as radiological landmarks, with a 1.5 cm safety margin. The accuracy of tip positioning with the radiological landmark-based technique (R) and Peres' formula (P) was compared using transoesophageal echocardiography. Real-time ultrasound-guided central venous catheter insertion was done through the right internal jugular or subclavian vein. Patients were randomly assigned to either the P group (n=93) or the R group (n=95). Optimal catheter tip position was considered to be within 2 cm above and 1 cm below the RA-SVC junction. Catheter tip position, abutment, angle to the vascular wall, and flow stream were evaluated on a bicaval view. The distance from the skin insertion point to the RA-SVC junction and determined depth of catheter insertion were more strongly correlated in the R group [17.4 (1.2) and 16.7 (1.5) cm; r=0.821, P<0.001] than in the P group [17.3 (1.2) and 16.4 (1.1) cm; r=0.517, P<0.001], with z=3.96 (P<0.001). More tips were correctly positioned in the R group than in the P group (74 vs 93%, P=0.001). Abutment, tip angle to the lateral wall >40°, and disrupted flow stream were comparable. Catheter tip position was more accurate with a radiological landmark-based technique than with Peres' formula. Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp KCT0001937. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    PubMed

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  9. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    PubMed Central

    Allam, Abdallah El-Sayed; Khalil, Adham Aboul Fotouh; Eltawab, Basma Aly; Wu, Wei-Ting

    2018-01-01

    Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves. PMID:29808105

  10. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chibamore » needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.« less

  11. Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.

    PubMed

    Schallom, Marilyn E; Prentice, Donna; Sona, Carrie; Micek, Scott T; Skrupky, Lee P

    2012-06-01

    To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. Single-center, randomized, open label trial. Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. Three hundred forty-one patients with multilumen central venous catheters. Patients with at least one lumen with a minimum of two flushes were included in the analysis. Patients were randomly assigned within 12 hrs of central venous catheter insertion to receive either heparin or 0.9% sodium chloride flush. The primary outcome was lumen nonpatency. Secondary outcomes included the rates of loss of blood return, inability to infuse or flush through the lumen (flush failure), heparin-induced thrombocytopenia, and catheter-related blood stream infection. Assessment for patency was performed every 8 hrs in lumens without continuous infusions for the duration of catheter placement or discharge from intensive care unit. Three hundred twenty-six central venous catheters were studied yielding 709 lumens for analysis. The nonpatency rate was 3.8% in the heparin group (n = 314) and 6.3% in the 0.9% sodium chloride group (n = 395) (relative risk 1.66, 95% confidence interval 0.86-3.22, p = .136). The Kaplan-Meier analysis for time to first patency loss was not significantly different (log rank = 0.093) between groups. The rates of loss of blood return and flush failure were similar between the heparin and 0.9% sodium chloride groups. Pressure-injectable central venous catheters had significantly greater rates of nonpatency (10.6% vs. 4.3%, p = .001) and loss of blood return (37.0% vs. 18.8%, p <.001) compared to nonpressure-injectable catheters. The frequencies of heparin-induced thrombocytopenia and catheter-related blood stream infection were similar between groups. 0.9% sodium chloride and heparin flushing solutions have similar rates of lumen nonpatency. Given potential

  12. Incidence and risk factors for central venous access port-related infection in Chinese cancer patients.

    PubMed

    Wang, Ting-Yao; Lee, Kuan-Der; Chen, Ping-Tsung; Chen, Min-Chi; Chen, Yi-Yang; Huang, Cih-En; Kuan, Feng-Che; Chen, Chih-Cheng; Lu, Chang Hsien

    2015-11-01

    Cytotoxic chemotherapy via central venous access ports is an important part of the standard treatment for most cancers, but it is accompanied with the risk of infections. This study aimed to analyze the incidence and risk factors for central venous access port-related infection (CPI) among Chinese patients receiving cytotoxic chemotherapy. Between January 1, 2002 and December 31, 2005 a total of 1391 cancer patients with 1449 totally implantable central venous access ports were evaluated. The log-rank test and Cox proportional hazards model were used for the analyses of risk factors. The overall CPI incidence rate was 0.21 per 1000 catheter-days. Hematological malignancies and head and neck cancer were associated with an increased risk of CPI (hazard ratio 4.00 and 4.11, respectively, both p < 0.001) and less infection-free catheter longevity (p < 0.001) compared with other cancer types. Chemotherapy in an adjuvant setting was associated with a lower risk of infection than for patients in a nonadjuvant setting (p < 0.001). The most common pathogens isolated from CPI were Pseudomonas aeruginosa and Candida. Infection remains to be a challenging issue for totally implantable central venous ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings. Copyright © 2015. Published by Elsevier B.V.

  13. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  15. MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics

    PubMed Central

    Napoli, Alessandro; Sacconi, Beatrice; Battista, Giuseppe; Guglielmi, Giuseppe; Catalano, Carlo; Albisinni, Ugo

    2016-01-01

    MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a “new” interventional technique and on its applications for MSK and allied sciences. PMID:26607640

  16. High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy

    PubMed Central

    Copelan, Alexander; Hartman, Jason; Chehab, Monzer; Venkatesan, Aradhana M.

    2015-01-01

    Image-guided high-intensity focused ultrasound (HIFU) is an innovative therapeutic technology, permitting extracorporeal or endocavitary delivery of targeted thermal ablation while minimizing injury to the surrounding structures. While ultrasound-guided HIFU was the original image-guided system, MR-guided HIFU has many inherent advantages, including superior depiction of anatomic detail and superb real-time thermometry during thermoablation sessions, and it has recently demonstrated promising results in the treatment of both benign and malignant tumors. HIFU has been employed in the management of prostate cancer, hepatocellular carcinoma, uterine leiomyomas, and breast tumors, and has been associated with success in limited studies for palliative pain management in pancreatic cancer and bone tumors. Nonthermal HIFU bioeffects, including immune system modulation and targeted drug/gene therapy, are currently being explored in the preclinical realm, with an emphasis on leveraging these therapeutic effects in the care of the oncology patient. Although still in its early stages, the wide spectrum of therapeutic capabilities of HIFU offers great potential in the field of image-guided oncologic therapy. PMID:26622104

  17. Use of PTFE Stent Grafts for Hemodialysis-related Central Venous Occlusions: Intermediate-Term Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kundu, Sanjoy, E-mail: sanjoy_kundu40@hotmail.com; Modabber, Milad; You, John M.

    2011-10-15

    Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14),more » and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent

  18. [Disposable nursing applicator-pocket of indwelling central venous catheter].

    PubMed

    Wei, Congli; Ma, Chunyuan

    2017-11-01

    Catheter related infection is the most common complication of central venous catheter, which pathogen mainly originate from the pipe joint and the skin around puncture site. How to prevent catheter infection is an important issue in clinical nursing. The utility model disclosed a "disposable nursing applicator-pocket of indwelling central venous catheter", which is mainly used for the fixation and the protection. The main structure consists of two parts, one is medical applicator to protect the skin around puncture site, and the other is gauze pocket to protect the catheter external connector. When in use, the catheter connector is fitted into the pocket, and then the applicator is applied to cover the puncture point of the skin. Integrated design of medical applicator and gauze pocket was designed to realize double functions of fixation and protection. The disposable nursing applicator-pocket is made of medical absorbent gauze (outer layer) and non-woven fabric (inner layer), which has the characteristics of comfortable, breathable, dust filtered, bacteria filtered, waterproof, antiperspirant and anti-pollution. The utility model has the advantages of simple structure, low cost, simple operation, effective protection, easy realization and popularization.

  19. Comparison of right atrial pressure and central venous pressures measured at various anatomical locations in children.

    PubMed

    Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang

    2005-01-01

    To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.

  20. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization.

    PubMed

    Brass, Patrick; Hellmich, Martin; Kolodziej, Laurentius; Schick, Guido; Smith, Andrew F

    2015-01-09

    Central venous catheters (CVCs) can help with diagnosis and treatment of the critically ill. The catheter may be placed in a large vein in the neck (internal jugular vein), upper chest (subclavian vein) or groin (femoral vein). Whilst this is beneficial overall, inserting the catheter risks arterial puncture and other complications and should be performed with as few attempts as possible. Traditionally, anatomical 'landmarks' on the body surface were used to find the correct place in which to insert catheters, but ultrasound imaging is now available. A Doppler mode is sometimes used to supplement plain 'two-dimensional' ultrasound. The primary objective of this review was to evaluate the effectiveness and safety of two-dimensional (imaging ultrasound (US) or ultrasound Doppler (USD)) guided puncture techniques for insertion of central venous catheters via the internal jugular vein in adults and children. We assessed whether there was a difference in complication rates between traditional landmark-guided and any ultrasound-guided central vein puncture.Our secondary objectives were to assess whether the effect differs between US and USD; whether the effect differs between ultrasound used throughout the puncture ('direct') and ultrasound used only to identify and mark the vein before the start of the puncture procedure (indirect'); and whether the effect differs between different groups of patients or between different levels of experience among those inserting the catheters. We searched the Central Register of Controlled Trials (CENTRAL) (2013, Issue 1), MEDLINE (1966 to 15 January 2013), EMBASE (1966 to 15 January 2013), the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to 15 January 2013 ), reference lists of articles, 'grey literature' and dissertations. An additional handsearch focused on intensive care and anaesthesia journals and abstracts and proceedings of scientific meetings. We attempted to identify unpublished or ongoing studies

  1. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    NASA Astrophysics Data System (ADS)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.

  2. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    PubMed

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  3. Ultrasound-guided greater occipital nerve blocks and pulsed radiofrequency ablation for diagnosis and treatment of occipital neuralgia.

    PubMed

    Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-09-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.

  4. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    PubMed Central

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778

  5. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement

    PubMed Central

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically. PMID:29284881

  6. Postoperative Chylothorax of Unclear Etiology in a Patient with Right-sided Subclavian Central Venous Catheter Placement.

    PubMed

    Asghar, Samie; Shamim, Faisal

    2017-01-01

    A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.

  7. Horner syndrome after unsuccessful venous port implantation by cannulation of the right internal jugular vein.

    PubMed

    Nowak, Łukasz R; Duda, Krzysztof; Mizianty, Marek; Wilczek, Małgorzata; Bieda, Tomasz

    2015-01-01

    Horner syndrome is a rare but likely underdiagnosed complication of internal jugular vein cannulation. We present a case of a young woman undergoing chemotherapy for gestational trophoblastic disease for whom venous port implantation was attempted due to poor peripheral vein access. Despite ultrasound guidance, the procedure was unsuccessful and complicated by a local haematoma, causing compression of the sympathetic nerves with Horner syndrome. The symptoms subsided within 3 weeks without treatment. The possible pathomechanisms of Horner syndrome after central venous cannulation are presented with suggested diagnostic and therapeutic approaches. Special emphasis must be placed on excluding carotid artery dissection because it carries the risk of subsequent cerebral vascular incidents. In the event of a carotid dissection, a multidisciplinary team must choose a pharmacological (antiplatelet drugs/anticoagulation) or interventional approach. Even with ultrasonography, central venous cannulation is not free of serious risks. In case of anisocoria following an uneventful procedure, diagnostic imaging of the vascular structures in the neck is mandatory for the exclusion of potentially serious complications, such as carotid dissection or venous thrombosis.

  8. Ultrasound-guided thrombin injection of genicular artery pseudoaneurysm.

    PubMed

    Rachakonda, Aditya; Qato, Khalil; Khaddash, Tamim; Carroccio, Alfio; Pamoukian, Vicken; Giangola, Gary

    2015-07-01

    Pseudoaneurysm is a rare complication after arthroscopic procedures involving the knee. A 38-year-old man presented 1 month after right-knee arthroscopy with a 2-cm pulsating mass on the medial side of the right knee. Duplex ultrasound evaluation revealed 2.5 × 2.1-cm pseudoaneurysm just distal to the patella with arterialized flow communicating with the inferior medial genicular artery. Ultrasound-guided thrombin injection was performed in an office setting, and the resolution of active flow within the pseudoaneurysm was confirmed with duplex ultrasonography. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Endoscopic ultrasound-guided transesophageal thoracentesis for minimal pleural effusion.

    PubMed

    Rana, Surinder Singh; Sharma, Ravi; Gupta, Rajesh

    2018-06-19

    Pleural effusion is a common finding both in patients with benign and malignant diseases of pleura and lung with diagnostic thoracentesis establishing the diagnosis in the majority of cases. The diagnostic thoracentesis can be done either blindly or under the guidance of ultrasound or computed tomography. However, minimal pleural effusion is difficult to sample even under image guidance. Endoscopic ultrasound (EUS) is known to detect smaller volume of pleural effusion and, thus, can help in guiding thoracentesis. To analyze the safety and efficacy of EUS-guided diagnostic thoracentesis in patients with undiagnosed minimal pleural effusion retrospectively. Retrospective analysis of the data of patients with minimal pleural effusion, who underwent EUS-guided transesophageal diagnostic thoracentesis over last 2 years, was performed. Thirteen patients (11 male; mean age 46.7 ± 16.2 years) with undiagnosed minimal pleural effusion underwent successful EUS-guided transesophageal diagnostic thoracentesis using a 22-G needle. Seven (53%) patients had fever on presentation whereas two presented with cough and loss of appetite. Eight to 54 mL fluid was aspirated with an attempt to completely empty the pleural cavity. There were no complications of the procedure. EUS-guided diagnostic thoracentesis is a safe and effective alternative for evaluating patients with minimal pleural effusion.

  10. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. 'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.

    PubMed

    Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao

    2015-04-01

    The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.

  12. Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.

    PubMed

    Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason

    2017-05-01

    To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.

  13. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  14. Should nurses be trained to use ultrasound for intravenous access to patients with difficult veins?

    PubMed

    Smith, Claire

    2018-06-14

    Peripheral venous access is the most common invasive procedure performed on patients in the UK and is traditionally the responsibility of nursing staff. In an emergency, intravenous therapy can be lifesaving. Approximately 11% of adults have difficult venous access and are often subjected to repeated failed attempts, resulting in delayed diagnosis and treatment. Eventually, rescue methods are used by a doctor, but this increases demand on their time and the workflow of emergency departments. This article explores whether training nurses to obtain venous access using ultrasound would have a positive effect on doctors' workload and benefit adult patients with difficult veins. Research indicates that nurses can successfully use ultrasound to reduce the number of attempts, time to access and patient discomfort, and can prevent the insertion of unnecessary central lines. Ultrasound training programmes for nurses demonstrate benefits for patients and clinicians. © 2018 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.

  15. Low values of central venous oxygen saturation (ScvO2) during surgery and anastomotic leak of abdominal trauma patients.

    PubMed

    Isaza-Restrepo, Andres; Moreno-Mejia, Jose F; Martin-Saavedra, Juan S; Ibañez-Pinilla, Milciades

    2017-01-01

    There is a well known relationship between hypoperfusion and postoperative complications like anastomotic leak. No studies have been done addressing this relationship in the context of abdominal trauma surgery. Central venous oxygen saturation is an important hypoperfusion marker of potential use in abdominal trauma surgery for identifying the risk of anastomotic leak development. The purpose of this study was to identify the relationship between low values of central venous oxygen saturation and anastomotic leak of gastrointestinal sutures in the postoperative period in abdominal trauma surgery. A cross-sectional prospective study was performed. Patients over 14 years old who required surgical gastrointestinal repair secondary to abdominal trauma were included. Anastomotic leak diagnosis was confirmed through clinical manifestations and diagnostic images or secondary surgery when needed. Central venous oxygen blood saturation was measured at the beginning of surgery through a central catheter. Demographic data, trauma mechanism, anatomic site of trauma, hemoglobin levels, abdominal trauma index, and comorbidities were assessed as secondary variables. Patients who developed anastomotic leak showed lower mean central venous oxygen saturation levels (60.0% ± 2.94%) than those who did not (69.89% ± 7.21%) ( p  = 0.010). Central venous oxygen saturation <65% was associated with the development of gastrointestinal leak during postoperative time of patients who underwent surgery secondary to abdominal trauma.

  16. Conventional Landmark-Guided Midline Versus Preprocedure Ultrasound-Guided Paramedian Techniques in Spinal Anesthesia.

    PubMed

    Kallidaikurichi Srinivasan, Karthikeyan; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2015-10-01

    Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of postdural puncture headache, paraesthesia, and spinal hematoma. We hypothesized that the routine use of a preprocedural ultrasound-guided paramedian technique for spinal anesthesia would reduce the number of passes required to achieve entry into the subarachnoid space when compared with the conventional landmark-guided midline approach. One hundred consenting patients scheduled for elective total joint replacements (hip and knee) were randomized into group C (conventional) and group P (preprocedural ultrasound-guided paramedian technique) with 50 in each group. The patients were blinded to the study group. All spinal anesthetics were administered by a consultant anesthesiologist. In group C, spinal anesthetic was done via the midline approach using clinically palpated landmarks. In group P, a preprocedural ultrasound scan was used to mark the paramedian insertion site, and spinal anesthetic was performed via the paramedian approach. The average number of passes (defined as the number of forward advancements of the spinal needle in a given interspinous space, i.e., withdrawal and redirection of spinal needle without exiting the skin) in group P was approximately 0.34 times that in group C, a difference that was statistically significant (P = 0.01). Similarly, the average number of attempts (defined as the number of times the spinal needle was withdrawn from the skin and reinserted) in group P was approximately 0.25 times that of group C (P = 0.0021). In group P, on an average, it took 81.5 (99% confidence interval, 68.4-97 seconds) seconds longer to identify the landmarks than in group C (P = 0.0002). All other parameters, including grading of palpated landmarks, time taken for spinal anesthetic injection, periprocedural pain scores, periprocedural patient discomfort visual analog scale score, conversion to general anesthetic, paresthesia, and radicular pain

  17. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  18. A Contemporary Assessment of Mechanical Complication Rates and Trainee Perceptions of Central Venous Catheter Insertion.

    PubMed

    Heidemann, Lauren; Nathani, Niket; Sagana, Rommel; Chopra, Veneet; Heung, Michael

    2017-08-01

    Limited data exist regarding rates of mechanical complications of ultrasound-guided, nontunneled central venous catheters (CVC). Similarly, trainee perceptions surrounding CVC complications are largely unknown. To evaluate contemporary CVC mechanical complication rates, associated risk factors, and trainee perspectives. A single-center retrospective review of CVC procedures between June 1, 2014, and May 1, 2015. Electronic survey distributed to internal medicine trainees. Intensive care units and the emergency department at an academic hospital. Electronic health records of patients with CVC procedures were reviewed for complications. Demographic and procedural characteristics were compared for complicated vs uncomplicated procedures. Student t tests and chi-square tests were used to compare continuous and categorical variables, respectively. Of the 730 reviewed records, 14 serious mechanical complications occurred due to pneumothorax (n = 5), bleeding (n = 3), vascular injury (n = 3), stroke (n = 1), and death (n = 2). Risk factors for complicated vs uncomplicated CVC placement included subclavian location (21.4% vs 7.8%, = 0.001), number of attempts (2.2 vs 1.5, = 0.02), unsuccessful CVC (21.4% vs. 4.3%, = 0.001), attending supervision (61.5% vs 34.7%, = 0.04), low body mass index (mean 25.7 kg/ m² vs 31.5 kg/m², = 0.001), anticoagulation (28.6% vs 20.6%, = 0.048), and ventilation (78.5% vs 66.5%, = 0.001). Survey data suggested deficiencies in managing unsuccessful CVC procedures; specifically, only 35% (N = 21/60) of trainees regularly perform chest x-rays after failed CVC attempt. We observed a 1.9% rate of mechanical complications associated with CVC placement. Our study confirms historical data that unsuccessful CVC attempts are an important risk factor for complications. Education regarding unsuccessful CVC placement may improve patient safety. © 2017 Society of Hospital Medicine

  19. Efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

    PubMed

    Duan, Xu; Ling, Feng; Shen, Yun; Yang, Jun; Xu, Hai-ying; Tong, Xiao-shan

    2013-04-01

    We investigated the efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation. A total of 40 consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantations were included in the study. Patients were randomly assigned to control group and nitroglycerin group. Patients in the nitroglycerin group were given 200 µg (2 mL) nitroglycerin via ipsilateral peripheral vein about 3 min before puncture. The degree of venous spasm was evaluated by the reduction in lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in lumen calibre of 50-90% and ≥ 90%, respectively. The mean degree of venous spasm of axillary vein was lower in the nitroglycerin group than in the control group (23.0 ± 22.3 vs. 45.5 ± 33.6%, P = 0.018). The incidence of mild or severe venous spasm was lower in the nitroglycerin group than in the control group (3/20 vs. 11/20, P = 0.019). In the nitroglycerin group, the systolic blood pressure had a significant decrease after puncture (129.5 ± 23.7 vs. 143.0 ± 24.1 mmHg, P = 0.003). There was no hypotension and other adverse reaction of nitroglycerin in the nitroglycerin group. Intravenous nitroglycerin is effective and safe for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

  20. Critical Care Ultrasound: A Review for Practicing Nephrologists.

    PubMed

    Wilson, Jennifer G; Breyer, Kristine E W

    2016-05-01

    The use of point-of-care ultrasound in the intensive care unit, both for diagnostic and procedural purposes, has rapidly proliferated, and evidence supporting its use is growing. Conceptually, critical care ultrasound (CCUS) should be considered an extension of the physical examination and should not be considered a replacement for formal echocardiography or radiology-performed ultrasound. Several CCUS applications are of particular relevance to nephrologists, including focused renal ultrasound in patients at high risk for urinary tract obstruction, real-time ultrasound guidance and verification during the placement of central venous catheters, and ultrasound-augmented assessment of shock and volume status. Each of these applications has the capacity to improve outcomes in patients with acute kidney injury. Although robust evidence regarding long-term outcomes is lacking, existing data demonstrate that CCUS has the potential to improve diagnostic accuracy, expedite appropriate management, and increase safety for critically ill patients across a spectrum of pathologies. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  1. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    PubMed

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. In-line positioning of ultrasound images using wireless remote display system with tablet computer facilitates ultrasound-guided radial artery catheterization.

    PubMed

    Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo

    2016-02-01

    Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.

  3. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    PubMed

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Brachial arteriovenous fistula as a complication of placement of a peripherally inserted central venous catheter: a case report and review of the literature.

    PubMed

    Tran, Hoang S; Burrows, Brian J; Zang, William A; Han, David C

    2006-09-01

    Peripherally inserted central venous catheter (PICC) lines have become a frequently used method of intravenous access for long-term administration of antibiotics, chemotherapy, and parenteral nutrition. Catheter-related complications involving the arterial tree are rare. We report a case of a 25-year-old woman with a history of difficult PICC line placement that presented with an arteriovenous fistula in the left arm. Duplex ultrasound confirmed the diagnosis of a brachial artery-to-brachial vein arteriovenous fistula (AVF), and the patient underwent surgical repair. To our knowledge, this is the first reported case of an AVF resulting from PICC line placement. Correction of AVF is indicated to alleviate symptoms as well as to prevent future complications.

  5. Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays

    DTIC Science & Technology

    2001-10-25

    81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased

  6. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    PubMed

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  7. Lights, camera and action in the implementation of central venous catheter dressing.

    PubMed

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    To develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. This is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. The items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. The educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.

  8. [Ultrasound-guided rectus sheath block for upper abdominal surgery].

    PubMed

    Osaka, Yoshimune; Kashiwagi, Masanori; Nagatsuka, Yukio; Oosaku, Masayoshi; Hirose, Chikako

    2010-08-01

    Upper abdominal surgery leads to severe postoperative pain. Insufficient postoperative analgesia accompanies a high incidence of complications. Therefore, postoperative analgesia is very important. The epidural analgesia has many advantages. However it has a high risk of epidural hematoma in anticoagulated patients. Rectus sheath block provided safer and more reliable analgesia in recent years, by the development of ultrasound tools. We experienced two cases of the rectus sheath block in upper abdominal surgery under ultrasound guidance. Ultrasound guided rectus sheath block can reduce the risk of peritoneal puncture, bleeding, and other complications. Rectus sheath block is very effective to reduce postoperative pain in upper abdominal surgery as an alternative method to epidural anesthesia in anticoagulated patients.

  9. [Complications associated to central venous catheters in hematology patients].

    PubMed

    García-Gabás, Carmen; Castillo-Ayala, Ana; Hinojo-Marín, Begoña; Muriel-Abajo, M Ángeles; Gómez-Gutiérrez, Isabel; de Mena-Arenas, Ana M; Rodríguez-Gonzalo, Ana; Chao-Lozano, Cristina; García-Menéndez, Carmen; Madroñero-Agreda, M Antonia

    2015-01-01

    To discover the incidence of central venous catheters (tunnelled, subcutaneous and PICC) in patients with onco-hematological conditions, hospitalized in the Hematology or Transplantations of Hematopoietic Stem Cells Units, in two tertiary care hospitals. A cross-sectional, descriptive study form was developed in order to gather sociodemographic, clinical data as well as complications and follow-up of the care protocol. Each catheter was assigned a correlative identification number. Information was collected on 366 catheters: 185 in the University Hospital Ramón y Cajal (HURYC), 80 tunnelled, 40 subcutaneous venous access and 65 PICC, and 181 in the University Hospital Gregorio Marañón (HUGM), 101 tunnelled and 80 subcutaneous venous access. Major complications in the tunnellized were infections (13.7% in HURYC vs. 6.8% in HUGM - p<0.001) and occlusions (at least once in 3.8% vs. 21.8%). In subcutaneous venous access, infections were confirmed in 5% in HURYC vs. 1.2% in HUGM. There were occlusions at least once in 10% in HUGM and no other significant complications were detected. Regarding PICC, information was only collected in HURYC, where complications were phlebitis 10.8%, thrombosis 7.7%, confirmed or suspected infection 4.6%, occlusion at least once 7.7%. Differences between hospitals with regard to major complications, infection and occlusion may be related to different care protocol. We need to stress the high incidence of phlebitis and thrombosis in PICC catheters, compared with data of lower incidence of other papers. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  10. An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, Shamit S., E-mail: shamit.desai@northwestern.edu; Konanur, Meghana; Foltz, Gretchen

    PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared andmore » externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.« less

  11. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    PubMed

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  12. A randomised crossover study to compare the cross-sectional and longitudinal approaches to ultrasound-guided peripheral venepuncture in a model.

    PubMed

    Griffiths, James; Carnegie, Amadeus; Kendall, Richard; Madan, Rajeev

    2017-12-01

    Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we investigated whether novice ultrasound users should adopt a cross-sectional or longitudinal approach when learning to access peripheral veins under ultrasound guidance. This result would inform the development of a structured training method for this procedure. We conducted a randomised controlled trial of 30 medical students. Subjects received 35 min of training, then attempted to aspirate 1 ml of synthetic blood from a deep vein in a training model under ultrasound guidance. Subjects attempted both the cross-sectional and longitudinal approaches. Group 1 used cross-sectional first, followed by longitudinal. Group 2 used longitudinal first, then cross-sectional. We measured the time from first puncture of the model's skin to aspiration of fluid, and the number of attempts required. Subjects also reported difficulty ratings for each approach. Paired sample t-tests were used for statistical analysis. The mean number of attempts was 1.13 using the cross-sectional approach, compared with 1.30 using the longitudinal approach (p = 0.17). Mean time to aspiration of fluid was 45.1 s using the cross-sectional approach and 52.8 s using the longitudinal approach (p = 0.43). The mean difficulty score out of 10 was 3.97 for the cross-sectional approach and 3.93 for the longitudinal approach (p = 0.95). We found no significant difference in effectiveness between the cross-sectional and longitudinal approaches to ultrasound-guided venepuncture when performed on a model. We believe that both approaches should be included when teaching ultrasound-guided peripheral vascular access. To confirm which approach would be best in clinical practice, we advocate future testing of both approaches on patients.

  13. Potential involvement of the extracranial venous system in central nervous system disorders and aging

    PubMed Central

    2013-01-01

    Background The role of the extracranial venous system in the pathology of central nervous system (CNS) disorders and aging is largely unknown. It is acknowledged that the development of the venous system is subject to many variations and that these variations do not necessarily represent pathological findings. The idea has been changing with regards to the extracranial venous system. Discussion A range of extracranial venous abnormalities have recently been reported, which could be classified as structural/morphological, hemodynamic/functional and those determined only by the composite criteria and use of multimodal imaging. The presence of these abnormalities usually disrupts normal blood flow and is associated with the development of prominent collateral circulation. The etiology of these abnormalities may be related to embryologic developmental arrest, aging or other comorbidities. Several CNS disorders have been linked to the presence and severity of jugular venous reflux. Another composite criteria-based vascular condition named chronic cerebrospinal venous insufficiency (CCSVI) was recently introduced. CCSVI is characterized by abnormalities of the main extracranial cerebrospinal venous outflow routes that may interfere with normal venous outflow. Summary Additional research is needed to better define the role of the extracranial venous system in relation to CNS disorders and aging. The use of endovascular treatment for the correction of these extracranial venous abnormalities should be discouraged, until potential benefit is demonstrated in properly-designed, blinded, randomized and controlled clinical trials. Please see related editorial: http://www.biomedcentral.com/1741-7015/11/259. PMID:24344742

  14. Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

    PubMed

    Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J

    2006-01-01

    Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.

  15. Comparative Evaluation of Two Venous Sampling Techniques for the Assessment of Pancreatic Insulin and Zinc Release upon Glucose Challenge.

    PubMed

    Pillai, Anil Kumar; Silvers, William; Christensen, Preston; Riegel, Matthew; Adams-Huet, Beverley; Lingvay, Ildiko; Sun, Xiankai; Öz, Orhan K

    2015-01-01

    Advances in noninvasive imaging modalities have provided opportunities to study β cell function through imaging zinc release from insulin secreting β cells. Understanding the temporal secretory pattern of insulin and zinc corelease after a glucose challenge is essential for proper timing of administration of zinc sensing probes. Portal venous sampling is an essential part of pharmacological and nutritional studies in animal models. The purpose of this study was to compare two different percutaneous image-guided techniques: transhepatic ultrasound guided portal vein access and transsplenic fluoroscopy guided splenic vein access for ease of access, safety, and evaluation of temporal kinetics of insulin and zinc release into the venous effluent from the pancreas. Both techniques were safe, reproducible, and easy to perform. The mean time required to obtain desired catheter position for venous sampling was 15 minutes shorter using the transsplenic technique. A clear biphasic insulin release profile was observed in both techniques. Statistically higher insulin concentration but similar zinc release after a glucose challenge was observed from splenic vein samples, as compared to the ones from the portal vein. To our knowledge, this is the first report of percutaneous methods to assess zinc release kinetics from the porcine pancreas.

  16. [Risk factors of deep venous thrombosis associated with peripherally inserted central venous catheter in upper extremity in ICU].

    PubMed

    Zhao, Ning; Zhang, Jiale; Jiang, Ting; Chen, Xia; Wang, Jianning; Ding, Chengzhi; Liu, Fen; Qian, Kejian; Jiang, Rong

    2017-02-01

    To analyze the incidence and its risk factors of peripherally inserted central venous catheter related upper extremity deep venous thrombosis (PICC-UEDVT) in intensive care unit (ICU). Clinical data of the patients received PICCs in ICU of the First Affiliated Hospital of Nanchang University from August 2013 to August 2016 were retrospectively analysed. The inclusion criteria in the study included: the age > 18 years old, catheter indwelling time > 1 week and the complete relevant information. The gender, age, history of deep venous thrombosis (DVT) and PICC; number of illness involved organs; complicated with hypertension, diabetes, infection or not; and acute physiology and chronic health evaluation II (APACHE II), duration of mechanical ventilation; D-dimer, platelet count (PLT), and activated partial thromboplastin time (APTT) were recorded. According to the occurrence of PICC-UEDVT, univariate analysis was performed to identify the risk factors of PICC-UEDVT and variables with statistical difference were selected to do multivariate binary logistic regression analysis for the confirmable independence risk factors. Six patients of the 61 cases occurred PICC-UEDVT with the occurrence rate of 9.8%. Time of occurrence was 9 days, 14 days (2 cases), 22 days, 28 days, 62 days after inserted catheter respectively. Univariate analysis demonstrated that previous DVT, D-dimer and big diameter PICC were risk factors associated with PICC-UEDVT [the previous DVT: 50.00% vs. 7.27%, P = 0.017; D-dimer > 5 mg/L: 66.67% vs. 18.18%, P = 0.021; 5F catheter: 83.33% vs. 29.09%, P = 0.016]. It was shown by multivariate logistic regression analysis that the previous DVT [odds ratio (OR) = 20.539, 95% confidence interval (95%CI) = 1.733-243.875, P = 0.017] and increasing size of catheter (OR = 18.070, 95%CI = 1.317-247.875, P = 0.030) were independent risk factors associated with the development of PICC-UEDVT. For critical patients with a history of DVT and D-dimer > 5 mg

  17. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  18. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    NASA Astrophysics Data System (ADS)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  19. Results of surgery in symptomatic non-hydrocephalic pineal cysts: role of magnetic resonance imaging biomarkers indicative of central venous hypertension.

    PubMed

    Eide, Per Kristian; Ringstad, Geir

    2017-02-01

    We have previously proposed that pineal cysts (PCs) may result in crowding of the pineal recess, causing symptoms due to compression of the internal cerebral veins and central venous hypertension. In the present study, we compared clinical outcome of different treatment modalities in symptomatic individuals with non-hydrocephalic PCs. The study included all patients managed surgically for non-hydrocephalic PCs in our Department of Neurosurgery over a 10-year period. We applied a questionnaire to determine occurrence of symptoms before and after surgery, which allowed the use of a grading scale for symptom severity. Magnetic resonance imaging (MRI) biomarkers indicative of central venous hypertension were assessed before and after surgery. Relief of symptoms after surgery was most efficiently obtained by complete microsurgical cyst removal [n = 15; no (0/15), some (1/15) or marked (14/15) improvement], and to a lesser extent by microsurgical cyst fenestration [n = 6; no (2/6), some (4/6) or marked (0/6) improvement]. Shunt surgery was not successful [n = 6; no (5/6), some (1/6) or marked (0/6) improvement]. In all patients, the proposed MRI biomarkers gave evidence of central venous hypertension (PC grades 2-4). Microsurgical cyst removal provided marked symptom relief in symptomatic individuals with non-hydrocephalic PCs and MRI biomarkers of central venous hypertension. The hypothesis that PC-induced crowding of the pineal recess may compromise venous run-off and induce a central venous hypertension syndrome deserves further study.

  20. Teaching medical students ultrasound-guided vascular access - which learning method is best?

    PubMed

    Lian, Alwin; Rippey, James C R; Carr, Peter J

    2017-05-15

    Ultrasound is recommended to guide insertion of peripheral intravenous vascular cannulae (PIVC) where difficulty is experienced. Ultrasound machines are now common-place and junior doctors are often expected to be able to use them. The educational standards for this skill are highly varied, ranging from no education, to self-guided internet-based education, to formal, face-to-face traditional education. In an attempt to decide which educational technique our institution should introduce, a small pilot trial comparing educational techniques was designed. Thirty medical students were enrolled and allocated to one of three groups. PIVC placing ability was then observed, tested and graded on vascular access phantoms. The formal, face-to-face traditional education was rated best by the students, and had the highest success rate in PIVC placement, the improvement statistically significant compared to no education (p = 0.01) and trending towards significance when compared to self-directed internet-based education (p<0.06). The group receiving traditional face-to-face teaching on ultrasound-guided vascular access, performed significantly better than those not receiving education. As the number of ultrasound machines in clinical areas increases, it is important that education programs to support their safe and appropriate use are developed.

  1. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    PubMed

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  2. [Comparison of transverse short-axis classic and oblique long-axis "Syringe-Free" approaches for internal jugular venous catheterization under ultrasound guidance].

    PubMed

    Ince, Ilker; Arı, Muhammet Ali; Sulak, Muhammet Mustafa; Aksoy, Mehmet

    There are different ultrasound probe positions used for internal jugular venous catheter placement. Also, in-plane or out of plane needle approach may be used for catheterization. Transverse short-axis classic approach is the most popular performed approach in literature. "Syringe-Free" is a new described technique that is performed with oblique long-axis approach. We aimed to compare performance of these two approaches. This study was conducted as a prospective and randomized study. 80 patients were included the study and divided into two groups that were named Group C (transverse short-axis classic approach) and Group SF (oblique long-axis syringe-free approach) by a computer-generated randomization. The primary outcome was mean time that guidewire is seen in the internal jugular vein (performing time). The secondary outcomes were to compare number of needle pass, number of skin puncture and complications between two groups. Demographic and hemodynamic data were not significantly different. The mean performing time was 54.9±19.1s in Group C and 43.9±15.8s in Group SF. Significant differences were found between the groups (p=0.006). Mean number of needle pass was 3.2(±2.1) in Group C and 2.1(±1.6) in Group SF. There were statistically significant differences between two groups (p=0.002). The number of skin puncture was 1.6(±0.8) and 1.2(±0.5) in Group C and SF, respectively (p=0.027). "Syringe-Free" technique has lower performing time, number of needle pass and skin puncture. Also, it allows to follow progress of guide-wire under continuous ultrasound visualization and the procedure does not need assistance during catheter insertion. Namely, "Syringe-Free" is effective, safe and fast technique that may be used to place internal jugular venous catheter. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. A cMUT probe for ultrasound-guided focused ultrasound targeted therapy.

    PubMed

    Gross, Dominique; Coutier, Caroline; Legros, Mathieu; Bouakaz, Ayache; Certon, Dominique

    2015-06-01

    Ultrasound-mediated targeted therapy represents a promising strategy in the arsenal of modern therapy. Capacitive micromachined ultrasonic transducer (cMUT) technology could overcome some difficulties encountered by traditional piezoelectric transducers. In this study, we report on the design, fabrication, and characterization of an ultrasound-guided focused ultrasound (USgFUS) cMUT probe dedicated to preclinical evaluation of targeted therapy (hyperthermia, thermosensitive liposomes activation, and sonoporation) at low frequency (1 MHz) with simultaneous ultrasonic imaging and guidance (15 to 20 MHz). The probe embeds two types of cMUT arrays to perform the modalities of targeted therapy and imaging respectively. The wafer-bonding process flow employed for the manufacturing of the cMUTs is reported. One of its main features is the possibility of implementing two different gap heights on the same wafer. All the design and characterization steps of the devices are described and discussed, starting from the array design up to the first in vitro measurements: optical (microscopy) and electrical (impedance) measurements, arrays' electroacoustic responses, focused pressure field mapping (maximum peak-to-peak pressure = 2.5 MPa), and the first B-scan image of a wire-target phantom.

  4. Ultrasound-Guided Cryoanalgesia of Peripheral Nerve Lesions.

    PubMed

    Djebbar, Sahlya; Rossi, Ignacio M; Adler, Ronald S

    2016-11-01

    The real-time nature of ultrasound makes it ideally suited to provide guidance for a variety of musculoskeletal interventional procedures involving peripheral nerves. Continuous observation of the needle ensures proper placement and allows continuous monitoring when performing localized ablative therapy and therefore more accurate positioning of a cryoprobe, use of smaller needles, as well as access to small structures. We describe our experience performing cryoablative procedures. Patients undergoing cryoneurolysis have largely reported varying degrees of long-term pain relief and improvement in function; no serious complications have yet been identified. Ultrasound-guided cryoneurolysis can provide a useful, safe alternative to other ablative techniques to achieve long-term analgesia from painful peripheral nerve lesions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. A multimodal image guiding system for Navigated Ultrasound Bronchoscopy (EBUS): A human feasibility study

    PubMed Central

    Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav

    2017-01-01

    Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758

  6. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  7. A Randomized Double-Blinded Trial on the Effects of Ultrasound Transducer Orientation on Teaching and Learning Ultrasound-Guided Regional Anesthesia.

    PubMed

    Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R

    2016-07-01

    Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.

  8. Influence of Ankle Active Dorsiflexion Movement Guided by Inspiration on the Venous Return From the Lower Limbs: A Prospective Study.

    PubMed

    Pi, Hongying; Ku, Hong'an; Zhao, Ting; Wang, Jie; Fu, Yicheng

    2018-04-01

    Active ankle movement is recommended intervention for preventing deep vein thrombosis effectively and easily by promoting venous return from the lower limbs. The active ankle dorsiflexion and plantar flexion movement guided by deep breathing is considered the most effective method, although outstanding problems remain, including low patient compliance and difficult motion essentials. The aims of this study were to compare the influence of different ankle active movements on venous return from the lower limbs and to suggest the optimal movement for preventing deep venous thrombosis in the lower limbs. A self-controlled study on 130 subjects was undertaken. The femoral venous hemodynamics of the left femoral vein and changes in pulse oxygen saturation and heart rate were compared among the three states of quiescent, active ankle 30° dorsiflexion movement, and active ankle 30° dorsiflexion with active plantar 45° flexion movement. The immediate master rates of the two ankle movements were examined before the study. The femoral venous hemodynamics of the left femoral vein were significantly higher in both movement states compared with the quiescent state. Moreover, no significant difference was found among the three states in terms of pulse oxygen saturation and heart rate. The immediate master rate was significantly higher in the active ankle 30° dorsiflexion movement than in the active ankle 30° dorsiflexion and active plantar 45° flexion movement. Therefore, active ankle 30° dorsiflexion movement guided by inspiration was found in this study to increase femoral venous hemodynamics, which heightened the immediate master rate but had no obvious influence on pulse oxygen saturation and heart rate. Active ankle 30° dorsiflexion movement guided by inspiration effectively promotes venous return from the lower limbs and is a better method to prevent deep vein thrombosis of the lower limbs.

  9. Hand dominance in intravenous drug using patients does not affect peripheral venous access sites identified by ultrasound.

    PubMed

    Kaban, Nicole L; Avitabile, Nicholas C; Siadecki, Sebastian D; Saul, Turandot

    2016-06-01

    The peripheral veins in the arms and forearms of patients with a history of intravenous (IV) drug use may be sclerosed, calcified, or collapsed due to damage from previous injections. These patients may consequently require alternative, more invasive types of vascular access including central venous or intraosseous catheters. We investigated the relationship between hand dominance and the presence of patent upper extremity (UE) veins specifically in patients with a history of IV drug-use. We predicted that injection into the non-dominant UE would occur with a higher frequency than the dominant UE, leading to fewer damaged veins in the dominant UE. If hand dominance affects which upper extremity has more patent veins, providers could focus their first vascular access attempt on the dominant upper extremity. Adult patients were approached for enrollment if they provided a history of IV drug use into one of their upper extremities. Each upper extremity was examined with a high frequency linear transducer in 3 areas: the antecubital crease, forearm and the proximal arm. The number of fully compressible veins ≥1.8 mm in diameter was recorded for each location. The mean vein difference between the numbers of veins in the dominant versus the non-dominant UE was -1.5789. At a .05 significance level, there was insufficient evidence to suggest the number of compressible veins between patients' dominant and non-dominant arms was significantly different (P = .0872.) The number of compressible veins visualized with ultrasound was not greater in the dominant upper extremity as expected. Practitioners may gain more information about potential peripheral venous access sites by asking patients their previous injection practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Variability in alignment of central venous pressure transducer to physiologic reference point in the intensive care unit-A descriptive and correlational study.

    PubMed

    Sjödin, Carl; Sondergaard, Soren; Johansson, Lotta

    2018-06-01

    The phlebostatic axis is the most commonly used anatomical external reference point for central venous pressure measurements. Deviation in the central venous pressure transducer alignment from the phlebostatic axis causes inadequate pressure readings, which may affect treatment decisions for critically ill patients in intensive care units. The primary aim of the study was to assess the variability in central venous pressure transducer levelling in the intensive care unit. We also assessed whether patient characteristics impacted on central venous pressure transducer alignment deviation. A sample of 61 critical care nurses was recruited and asked to place a transducer at the appropriate level for central venous pressure measurement. The measurements were performed in the intensive care unit on critically ill patients in supine and Fowler's positions. The variability among the participants using eyeball levelling and a laser levelling device was calculated in both sessions and adjusted for patient characteristics. A significant variation was found among critical care nurses in the horizontal levelling of the pressure transducer placement when measuring central venous pressure in the intensive care unit. Using a laser levelling device did not reduce the deviation from the phlebostatic axis. Patient characteristics had little impact on the deviation in the measurements. The anatomical external landmark for the phlebostatic axis varied between critical care nurses, as the variation in the central venous pressure transducer placement was not reduced with a laser levelling device. Standardisation of a zero-level for vascular pressures should be considered to reduce the variability in vascular pressure readings in the intensive care unit to improve patient treatment decisions. Further studies are needed to evaluate critical care nurses' knowledge and use of central venous pressure monitoring and whether assistive tools and/or routines can improve the accuracy in vascular

  11. Part versus Whole: A Randomized Trial of Central Venous Catheterization Education

    ERIC Educational Resources Information Center

    Chan, Angela; Singh, Sunita; Dubrowski, Adam; Pratt, Daniel D.; Zalunardo, Nadia; Nair, Parvarthy; McLaughlin, Kevin; Ma, Irene W. Y.

    2015-01-01

    Central venous catheterization (CVC) is a complex but commonly performed procedure. How best to teach this complex skill has not been clearly delineated. We conducted a randomized trial of the effects of two types of teaching of CVC on skill acquisition and retention. We randomly assigned novice internal medicine residents to learning CVC in-part…

  12. Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.

    PubMed

    Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun

    2015-06-01

    Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (P<0.01) and that in internal jugular vein catheterization (P<0.05). No statistically significant difference was found between femoral vein catheterization and internal jugular vein catheterization (P<0.05). Previous venous thrombosis history (P<0.01), high lactate dehydrogenase level (P<0.01), low high-density lipoprotein (HDL) level (P<0.05), and low albumin level (P<0.05) were found as risk factors or predictors of CVC-related venous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.

  13. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    PubMed Central

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  14. [Concordance between central venous and arterial blood gases in post-surgical myocardial revascularization patients in stable condition].

    PubMed

    Santos-Martínez, Luis Efren; Guevara-Carrasco, Marlene; Naranjo-Ricoy, Guillermo; Baranda-Tovar, Francisco Martín; Moreno-Ruíz, Luis Antonio; Herrera-Velázquez, Marco Antonio; Magaña-Serrano, José Antonio; Valencia-Sánchez, Jesús Salvador; Calderón-Abbo, Moisés Cutiel

    2014-01-01

    The concordance between the parameters of arterial and central venous blood gases has not been defined yet. We studied the concordance between both parameters in post-surgical myocardial revascularization patients in stable condition. Consecutive subjects were studied in a cross-sectional design. The position of the central venous catheter was performed and simultaneously we obtained arterial and central venous blood samples prior to discharge from the intensive care unit. Data are expressed according to Bland-Altman statistical method and the intraclass correlation coefficient. Statistical result was accepted at P<.05. Two hundred and six samples were studied of 103 post-surgical patients, pH and lactate had a mean difference (limits of agreement) 0.029±0.048 (-0018, 0.077) and -0.12±0.22 (-0.57, 0.33) respectively. The magnitude of the intraclass correlation coefficient was 0.904 and 0.943 respectively. The values related to oxygen pressure were 27.86±6.08 (15.9, 39.8) and oxygen saturation 33.02±6.13 (21, 45), with magnitude of 0.258 and 0.418 respectively. The best matching parameters between arterial and central venous blood samples were pH and lactate. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  15. Applications of Doppler ultrasound in clinical vascular disease

    NASA Technical Reports Server (NTRS)

    Barnes, R. W.; Hokanson, D. E.; Sumner, D. S.; Strandness, D. E., Jr.

    1975-01-01

    Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

  16. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advancedmore » techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.« less

  17. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures.

    PubMed

    Barile, Antonio; La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-09-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases.

  18. Palpation- and ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    da Cunha, Anderson F; Strain, George M; Rademacher, Nathalie; Schnellbacher, Rodney; Tully, Thomas N

    2013-01-01

    To compare palpation-guided with ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots. Prospective randomized experimental trial. Eighteen adult Hispaniolan Amazon parrots (Amazona ventralis) weighing 252-295 g. After induction of anesthesia with isoflurane, parrots received an injection of lidocaine (2 mg kg(-1)) in a total volume of 0.3 mL at the axillary region. The birds were randomly assigned to equal groups using either palpation or ultrasound as a guide for the brachial plexus block. Nerve evoked muscle potentials (NEMP) were used to monitor effectiveness of brachial plexus block. The palpation-guided group received the local anesthetic at the space between the pectoral muscle, triceps, and supracoracoideus aticimus muscle, at the insertion of the tendons of the caudal coracobrachial muscle, and the caudal scapulohumeral muscle. For the ultrasound-guided group, the brachial plexus and the adjacent vessels were located with B-mode ultrasonography using a 7-15 MHz linear probe. After location, an 8-5 MHz convex transducer was used to guide injections. General anesthesia was discontinued 20 minutes after lidocaine injection and the birds recovered in a padded cage. Both techniques decreased the amplitude of NEMP. Statistically significant differences in NEMP amplitudes, were observed within the ultrasound-guided group at 5, 10, 15, and 20 minutes after injection and within the palpation-guided group at 10, 15, and 20 minutes after injection. There was no statistically significant difference between the two groups. No effect on motor function, muscle relaxation or wing droop was observed after brachial plexus block. The onset of the brachial plexus block tended to be faster when ultrasonography was used. Brachial plexus injection can be performed in Hispaniolan Amazon parrots and nerve evoked muscle potentials were useful to monitor the effects on nerve conduction in this avian species. Neither technique produced an effective block at the

  19. Time-dependent hardening of blood clots quantitatively measured in vivo with shear-wave ultrasound imaging in a rabbit model of venous thrombosis.

    PubMed

    Mfoumou, Etienne; Tripette, Julien; Blostein, Mark; Cloutier, Guy

    2014-02-01

    Provide in vivo blood clot hardening evolution with ultrasound using supersonic imaging of shear waves. We conducted a prospective study in flow stasis-induced venous thrombosis within jugular veins of white female New Zealand rabbits. Blood clot elasticity was noninvasively measured in vivo using the Young's modulus (in kilopascals), on a 2-hour and a 2-week periods after thrombus induction. Monitoring was followed by a necropsy and ex vivo mechanical characterization to validate the existence and elasticity of explanted thrombi. Stagnant blood in the region of interest underwent clotting and progressive hardening with thrombus aging. The mean Young's moduli varied from 1.0 ± 0.6 kPa (at 10 min) to 5.3 ± 1.6 kPa (at 2 hours), then to 25.0 ± 6.8 kPa (at 14 days) post-surgery. Mean ex vivo moduli of 6.2 ± 0.7 kPa at 2 hours and 29.0 ± 2.4 kPa at 2 weeks agreed with in vivo measures. Supersonic imaging of shear waves provides consistent quantitative non-invasive elasticity measurements not available with standard compression ultrasound imaging for diagnosing and following venous thromboembolism. This information translatable to humans could aid in determining whether continued anticoagulant treatment is necessary, especially in the setting of unprovoked venous thromboembolism. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  1. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    PubMed

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  2. Transvaginal ultrasound-guided embryo transfer in IVF.

    PubMed

    Larue, L; Keromnes, G; Massari, A; Roche, C; Moulin, J; Gronier, H; Bouret, D; Cassuto, N G; Ayel, J P

    2017-05-01

    To determine whether transvaginal ultrasound-guided embryo transfer is a technique that can be used routinely, whether it improves IVF outcomes and whether it makes difficult transfers easier and more successful. Non-randomized retrospective study conducted between 2012 and 2016 in the fertility center of the Diaconesses-Croix St-Simon hospital group. The outcomes of 3910 transfers, performed by 5 senior operators, under transabdominal ultrasound guidance are compared with those of 800 transfers, performed by 1 senior operator under transvaginal ultrasound guidance. The criteria studied are the feasibility of the technique and the percentage of pregnancies per transfer in the two populations described, as well as in the difficult and very difficult transfer populations. All the transfers were feasible under transvaginal ultrasound guidance without the use of forceps or additional instruments. The percentage of pregnancies per transfer is significantly increased, when the transfer is performed under transvaginal ultrasound guidance compared with that performed under transabdominal ultrasound guidance, in the general population (38%, n=800 vs 30%, n=3910; P 0.0004) and in the reference population characterized by age <38 years and >6 oocytes collected per puncture (45%, n=490 vs 36%, n=1968; P 0.002). The percentage of pregnancies per transfer (P/T) is not significantly different in the populations of easy transfers (n 695, 38% P/T), difficult transfers (n 58, 46% P/T; P=ns) and very difficult transfers (n 47, 34% P/T; P=ns). Embryo transfer is a key stage in IVF, in which the quality of performance determines the outcome. In this study, transvaginal ultrasound guidance of the transfer, which is the reference procedure in gynaecological imaging, significantly increases the percentage of pregnancies per transfer, both in the general population and in the reference population, compared with transfers performed under transabdominal ultrasound guidance. Transvaginal

  3. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma.

    PubMed

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side ( P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  4. [Doctor-nurse delegation of the insertion of central venous lines].

    PubMed

    Cellupica, Mary

    2015-01-01

    The Léon Bérard Cancer Centre treats the disease in all its complexity with numerous disciplines such as surgery, medicine, radiotherapy, palliative care, home care, etc. The insertion of a central venous line is an essential part of cancer care and the nursing profession. It enables patients to have their treatment administered in the best possible conditions and without risk. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. [Superficial venous thrombosis. A state of art].

    PubMed

    Sándor, Tamás

    2017-01-01

    For a long time superficial thrombophlebitis has been thought to be a rather benign condition. Recently, when duplex ultrasound technique is used for the diagnosis more and more often, the disease is proved to be more dangerous than anticipated. Thrombosis propagates to the deep veins in 6-44% and pulmonary embolism was observed on the patients in 1,5-33%. We can calculate venous thromboembolic complications on every fourth patient. Diagnosis is clinical, but duplex ultrasound examination is mandatory, for estimation of the thrombus extent, for exclusion of the deep venous thrombosis and for follow up. Both legs should be checked with ultrasound, because simultaneous deep venous thrombosis can develop on the contralateral limb. Two different forms can be distinguished: superficial venous thrombosis with, or without varicose veins. In cases of spontaneous, non varicous form, especially when the process is migrating or recurrent, a careful clinical examination is necessery for exclusion of malignant diseases and thrombophilia. The treatment options are summarised on the basis of recent international consensus statements. The American and German guidelines are similar. Compression and mobilisation are cornerstones of the therapy. For a short segment thrombosis non steroidal antiinflammatory drugs are effective. For longer segments low molecular-weight heparins are preferred. Information on the effect of the novel oral anticoagulants for the therapy is lacking but they may appear to be effective in the future for this indication. When thrombus is close to the sapheno-femoral or sapheno-popliteal junction crossectomy (high ligation), or low molecular-weight heparin in therapeutic doses are indicated. The term superficial thrombophlebitis should be discouraged, because inflammation and infection is not the primary pathology. It should be called correctly superficial venous thrombosis in order to avoid the unnecessary administration of antibiotics and the misconception

  6. Non-contact hemodynamic imaging reveals the jugular venous pulse waveform

    NASA Astrophysics Data System (ADS)

    Amelard, Robert; Hughson, Richard L.; Greaves, Danielle K.; Pfisterer, Kaylen J.; Leung, Jason; Clausi, David A.; Wong, Alexander

    2017-01-01

    Cardiovascular monitoring is important to prevent diseases from progressing. The jugular venous pulse (JVP) waveform offers important clinical information about cardiac health, but is not routinely examined due to its invasive catheterisation procedure. Here, we demonstrate for the first time that the JVP can be consistently observed in a non-contact manner using a photoplethysmographic imaging system. The observed jugular waveform was strongly negatively correlated to the arterial waveform (r = -0.73 ± 0.17), consistent with ultrasound findings. Pulsatile venous flow was observed over a spatially cohesive region of the neck. Critical inflection points (c, x, v, y waves) of the JVP were observed across all participants. The anatomical locations of the strongest pulsatile venous flow were consistent with major venous pathways identified through ultrasound.

  7. Non-contact hemodynamic imaging reveals the jugular venous pulse waveform

    PubMed Central

    Amelard, Robert; Hughson, Richard L.; Greaves, Danielle K.; Pfisterer, Kaylen J.; Leung, Jason; Clausi, David A.; Wong, Alexander

    2017-01-01

    Cardiovascular monitoring is important to prevent diseases from progressing. The jugular venous pulse (JVP) waveform offers important clinical information about cardiac health, but is not routinely examined due to its invasive catheterisation procedure. Here, we demonstrate for the first time that the JVP can be consistently observed in a non-contact manner using a photoplethysmographic imaging system. The observed jugular waveform was strongly negatively correlated to the arterial waveform (r = −0.73 ± 0.17), consistent with ultrasound findings. Pulsatile venous flow was observed over a spatially cohesive region of the neck. Critical inflection points (c, x, v, y waves) of the JVP were observed across all participants. The anatomical locations of the strongest pulsatile venous flow were consistent with major venous pathways identified through ultrasound. PMID:28065933

  8. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  9. Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.

    PubMed

    Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu

    2015-11-01

    Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.

  10. Ultrasound-guided piriformis muscle injection. A new approach.

    PubMed

    Bevilacqua Alén, E; Diz Villar, A; Curt Nuño, F; Illodo Miramontes, G; Refojos Arencibia, F J; López González, J M

    2016-12-01

    Piriformis syndrome is an uncommon cause of buttock and leg pain. Some treatment options include the injection of piriformis muscle with local anesthetic and steroids. Various techniques for piriformis muscle injection have been described. Ultrasound allows direct visualization and real time injection of the piriformis muscle. We describe 5 consecutive patients, diagnosed of piriformis syndrome with no improvement after pharmacological treatment. Piriformis muscle injection with local anesthetics and steroids was performed using an ultrasound technique based on a standard technique. All 5 patients have improved their pain measured by numeric verbal scale. One patient had a sciatic after injection that improved in 10 days spontaneously. We describe an ultrasound-guided piriformis muscle injection that has the advantages of being effective, simple, and safe. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    PubMed

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  12. Distal Superficial Femoral Vein Cannulation for Peripherally Inserted Central Catheter Placement in Infants with Cardiac Disease.

    PubMed

    Richter, Robert P; Law, Mark A; Borasino, Santiago; Surd, Jessica A; Alten, Jeffrey A

    2016-12-01

    To describe a novel real-time ultrasound (US)-guided distal superficial femoral vein (DSFV) cannulation technique for insertion of peripherally inserted central catheters (PICC) in critically ill infants with congenital heart disease. Descriptive retrospective cohort study SETTING: Pediatric cardiac intensive care unit in a pediatric tertiary hospital PATIENTS: First 28 critically ill infants that received DSFV PICCs via this new technique. Thirty-seven US-guided DSFV PICCs were attempted on 31 infants from September 2012 to November 2014; 34 PICCs were placed in 28 patients (success rate 92%). Twenty-six of 28 patients underwent cardiac surgery. Median (IQR) age at time of PICC placement 39 days (13, 151); weight 3.4 kg (3.2, 5.3). 25/34 PICCs were placed in patients with STAT 4 or 5 category. Median PICC duration 16 days (11, 29); maximum duration 123 days. Ten infants (36%) had DSFV PICCs placed as the primary central venous access in perioperative period. Ten of 28 patients underwent cardiac catheterization while DSFV PICC was in place, four of which were performed through ipsilateral common femoral vein. Two patients had femoral arterial lines placed in the ipsilateral femoral artery while DSFV PICC was in place. There were no reported inadvertent arterial punctures. The PICC-associated infection rate was 4.6 per 1000 line days. Four of 34 DSFV PICCs (11.8%) were associated with deep venous thrombosis. DSFV is a novel venous access site for PICC placement with high success rate and sufficient longevity and flexibility for critically ill infants with cardiac disease. More experience and larger studies are needed to confirm its potential advantages. © 2016 Wiley Periodicals, Inc.

  13. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    PubMed

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  14. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    PubMed

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  15. Gestrinone combined with ultrasound-guided aspiration and ethanol injection for treatment of chocolate cyst of ovary.

    PubMed

    Wu, Xiaoyun; Xu, Yun

    2015-05-01

    The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  16. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients

    PubMed Central

    Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-01-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173

  17. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    PubMed

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  18. Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP.

    PubMed

    Mora Soler, Ana María; Álvarez Delgado, Alberto; Piñero Pérez, María Concepción; Velasco-Guardado, Antonio; Marcos Prieto, Héctor; Rodríguez Pérez, Antonio

    2018-05-01

    endoscopic ultrasound-guided biliary drainage (EUS-BD) is an alternative to percutaneous trans-hepatic biliary drainage (PTBD) in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). this is a retrospective description of six cases of endoscopic ultrasound-guided biliary drainage via choledochoduodenostomy (EUCD), as well as the clinical characteristics, endoscopic procedure, complications and monitoring. all cases had malignant distal biliary obstruction. The procedure was concluded with good drainage in four out of six patients. Two late complications were recorded that were caused by stent migration and there were no deaths related with the procedure. The average monitoring period was six months. EUCD can be considered as a valid therapeutic choice in some selected cases and when performed by a team of expert endoscopists in cases of failed ERCP drainage or as an alternative to PTBD. However, the procedure has some associated complications.

  19. [Ultrasound dynamics lysis apex thrombus as an objective criterion of effectiveness of anticoagulation therapy in venous thrombosis].

    PubMed

    Kalinin, R E; Suchkov, I A; Pshennikov, A S; Agapov, A B

    2016-01-01

    To assess the effectiveness of anticoagulant therapy (ACT) for the treatment of patients with deep venous thrombosis (DVT) of the lower extremities. The study considered ultrasonic characteristics of lysis of the proximal part of thrombus: localization and nature of venous thrombosis, the length and diameter of the proximal floating part of the thrombus, and duration of the venous thrombosis. Depending on the ACT options patients were divided into 3 groups: Group 1 (18 patients) received rivaroxaban, group 2 (19 patients) received enoxaparin sodium with subsequent transition to warfarin, and 3 group (19 patietns) received enoxaparin sodium, followed by administration of rivaroxaban. Treatment with rivaroxaban was preferable over standard ACT with enoxaparin/warfarin with regards to the lysis of thrombus when duration of thrombosis did not exceed 10 days. In 10.5% of patients who received warfarin flotation of thrombi remained for 14 days; the length of the floating part of the thrombi did not exceed 3 cm. Such circumstances and inability to reach a therapeutic INR value required cava filter placement. Treatment with enoxaparin sodium followed by the administration of rivaroxaban was found to be the most efficient ACT regimen as there was no negative dynamics of ultrasound characteristics of lysis of thrombi at any duration of the disease.

  20. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    PubMed

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p < 0.0001). When the thickness was greater or equal to 9.9 cm, drained volume was always more than 1000 ml. The measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  1. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures

    PubMed Central

    La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-01-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases. PMID:27302491

  2. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    PubMed

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  3. Long-term central venous access device selection.

    PubMed

    Gabriel, Janice

    Infusion therapy is often viewed as a means to an end - a way to administer medications and fluids. It is one of the few specialties that affect almost all areas of healthcare. Safe, effective and reliable vascular access should be the goal of every health professional who is starting a patient on a prescribed course of intravenous therapy, especially if that patient is undergoing a prolonged course. This article aims to refresh and update nurses' clinical knowledge of the detailed patient assessment required before choosing a central venous access device, as well as supporting a reduction in complications and earlier recognition of potential problems. It discusses clinical indications for devices, the range of long-term intravenous therapies that can be used, and patient assessment.

  4. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    PubMed

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  5. Comparative Evaluation of Two Venous Sampling Techniques for the Assessment of Pancreatic Insulin and Zinc Release upon Glucose Challenge

    PubMed Central

    Pillai, Anil Kumar; Silvers, William; Christensen, Preston; Riegel, Matthew; Adams-Huet, Beverley; Lingvay, Ildiko; Sun, Xiankai; Öz, Orhan K.

    2015-01-01

    Advances in noninvasive imaging modalities have provided opportunities to study β cell function through imaging zinc release from insulin secreting β cells. Understanding the temporal secretory pattern of insulin and zinc corelease after a glucose challenge is essential for proper timing of administration of zinc sensing probes. Portal venous sampling is an essential part of pharmacological and nutritional studies in animal models. The purpose of this study was to compare two different percutaneous image-guided techniques: transhepatic ultrasound guided portal vein access and transsplenic fluoroscopy guided splenic vein access for ease of access, safety, and evaluation of temporal kinetics of insulin and zinc release into the venous effluent from the pancreas. Both techniques were safe, reproducible, and easy to perform. The mean time required to obtain desired catheter position for venous sampling was 15 minutes shorter using the transsplenic technique. A clear biphasic insulin release profile was observed in both techniques. Statistically higher insulin concentration but similar zinc release after a glucose challenge was observed from splenic vein samples, as compared to the ones from the portal vein. To our knowledge, this is the first report of percutaneous methods to assess zinc release kinetics from the porcine pancreas. PMID:26273676

  6. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    DTIC Science & Technology

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine (Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine (Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US

  7. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of

  8. Lights, camera and action in the implementation of central venous catheter dressing1

    PubMed Central

    Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise

    2015-01-01

    Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters. PMID:26626011

  9. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    PubMed Central

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment. PMID:28900553

  10. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  11. Iatrogenic vertebral artery pseudoaneurysm due to central venous catheterization

    PubMed Central

    Vasquez, Jay

    2011-01-01

    Central venous lines have become an integral part of patient care, but they are not without complications. Vertebral artery pseudoaneurysm formation is one of the rarer complications of central line placement. Presented is a rare case of two pseudoaneurysms of the vertebral and subclavian artery after an attempted internal jugular vein catheterization. These were successfully treated with open surgical repair and bypass. Open surgical repair remains the gold standard of treatment. Endovascular repair of vertebral artery pseudoaneurysms has been described with promising outcomes, but long-term results are lacking. Ultimately, the best treatment of these iatrogenic injuries should start with prevention. Well-documented techniques to minimize mechanical complications, including inadvertent arterial puncture, should be practiced and taught in training programs to avoid the potentially devastating consequences. PMID:21566753

  12. [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

    PubMed

    Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A

    2012-10-01

    Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily

  13. Noninvasive treatment of deep venous thrombosis using pulsed ultrasound cavitation therapy (histotripsy) in a porcine model.

    PubMed

    Maxwell, Adam D; Owens, Gabe; Gurm, Hitinder S; Ives, Kimberly; Myers, Daniel D; Xu, Zhen

    2011-03-01

    This study evaluated histotripsy as a noninvasive, image-guided method of thrombolysis in a porcine model of deep vein thrombosis. Histotripsy therapy uses short, high-intensity, focused ultrasound pulses to cause mechanical breakdown of targeted soft tissue by acoustic cavitation, which is guided by real-time ultrasound imaging. This is an in vivo feasibility study of histotripsy thrombolysis. Acute thrombi were formed in the femoral vein of juvenile pigs weighing 30-40 kg by balloon occlusion with two catheters and thrombin infusion. A 10-cm-diameter 1-MHz focused transducer was used for therapy. An 8-MHz ultrasound imager was used to align the clot with the therapy focus. Therapy consisted of five cycle pulses delivered at a rate of 1 kHz and peak negative pressure between 14 and 19 MPa. The focus was scanned along the long axis of the vessel to treat the entire visible clot during ultrasound exposure. The targeted region identified by a hyperechoic cavitation bubble cloud was visualized via ultrasound during treatment. Thrombus breakdown was apparent as a decrease in echogenicity within the vessel in 10 of 12 cases and in 7 cases improved flow through the vein as measured by color Doppler. Vessel histology found denudation of vascular endothelium and small pockets of hemorrhage in the vessel adventitia and underlying muscle and fatty tissue, but perforation of the vessel wall was never observed. The results indicate histotripsy has potential for development as a noninvasive treatment for deep vein thrombosis. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  14. Peripherally Inserted Central Catheter Placement with the Sonic Flashlight: Initial Clinical Trial by Nurses

    PubMed Central

    Wang, David; Amesur, Nikhil; Shukla, Gaurav; Bayless, Angela; Weiser, David; Scharl, Adam; Mockel, Derek; Banks, Christopher; Mandella, Bernadette; Klatzky, Roberta; Stetten, George

    2010-01-01

    Objective We describe a case series comprising the first clinical trial by intravenous (IV) team nurses using the Sonic Flashlight for ultrasound guidance of peripherally inserted central catheter (PICC) placement. Methods Two IV team nurses with more than 10 years experience placing PICCs and from 3–6 years experience with ultrasound (US) attempted to place PICCs under US guidance in patients requiring long-term IV access. One of two methods of US guidance was used: conventional ultrasound (CUS) (60 patients) or a new device called the Sonic Flashlight (SF) (44 patients). The number of needle punctures required to gain IV access was recorded for each subject. Results In both methods, 87% of the cases resulted in successful venous access on the first attempt. The average number of needle sticks per patient was 1.18 for SF-guided procedures, as compared to 1.20 for CUS-guided procedures. No significant difference was found in the distribution of the number of attempts between the two methods. Anecdotal comments by the nurses indicated the comparative ease of use of the SF display, although relatively small scale of the SF image compared to the CUS image was also noted. Conclusions We have shown that the Sonic Flashlight is a safe and effective device for guidance of PICC placement in the hands of experienced IV team nurses. The advantage of placing the ultrasound image at its actual location must be balanced against the relatively small scale of the SF image. PMID:19389904

  15. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Osteoid Osteoma: A Case Series Report.

    PubMed

    Rovella, Marcello S; Martins, Guilherme L P; Cavalcanti, Conrado F A; Bor-Seng-Shu, Edson; Camargo, Olavo P; Cerri, Giovanni G; Menezes, Marcos R

    2016-04-01

    Osteoid osteoma is painful benign tumor. The aim of this study was to report our initial experience using magnetic resonance-guided focused ultrasound to treat osteoid osteomas. This retrospective single-center study included four patients treated with magnetic resonance-guided focused ultrasound. They presented with severe pain with reduced quality of life and a poor response to clinical treatment. The pre- and post-treatment evaluation comprised computed tomography and magnetic resonance imaging and focused on quality of life and the impact of pain on daily activities. After treatment, three patients had complete pain resolution with no recurrence. One patient had a recurrence of symptoms after 2 wk and underwent a new successful treatment with increased energy levels. On average, 13 sonications were administered (8-18 sonications/treatment) with an average energy of 2,003 J (range: 1,063-3,522 J). Magnetic resonance-guided focused ultrasound appears to be a feasible, tolerable and effective treatment in selected patients with osteoid osteomas. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Relationship between development of post-thrombotic syndrome and serial ultrasound, D-dimer, and factor VIII activity after a first deep venous thrombosis.

    PubMed

    Roberts, Lara N; Patel, Raj K; Goss, David E; Chitongo, Paradzai; Bonner, Lynda; Arya, Roopen

    2016-01-01

    The aim of this study was to evaluate the relationship of post-thrombotic syndrome (PTS) with residual vein thrombosis, deep venous reflux (DVT), D-dimer, and factor VIII (FVIII) after a first deep venous thrombosis (DVT). There were 133 participants with objectively confirmed DVT, of whom 114 were observed for 6 months after completion of anticoagulation. Ultrasound, D-dimer, and FVIII evaluations were undertaken at 6 weeks after completion of anticoagulation and at the end of follow-up. PTS was considered present in those with a score of ≥5 on the Villalta scale at either assessment. The cumulative incidence of PTS was 51.8%, with median duration of follow-up of 11 months. Median D-dimer and FVIII in those with PTS were significantly higher at both time points compared with those without. Similarly, residual vein thrombosis and deep venous reflux were more prevalent in those with PTS at both study assessments. On multivariable analysis, only FVIII at end of study remained significantly associated with PTS with an odds ratio of 2.83 (95% confidence interval, 1.09-7.42; P = .034). Ultrasound markers and D-dimer were not significantly associated with PTS after adjustment for age, body mass index, Charlson Index ≥1, and proximal extent of DVT. FVIII activity at end of follow-up was independently associated with PTS, suggesting underlying activation of coagulation. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  17. Ultrasound - Breast

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...

  18. Safety of ultrasound-guided high-intensity focused ultrasound ablation for diffuse adenomyosis: A retrospective cohort study.

    PubMed

    Feng, Yujie; Hu, Liang; Chen, Wenzhi; Zhang, Rong; Wang, Xi; Chen, Jinyun

    2017-05-01

    To evaluate the safety of ultrasound-guided high-intensity focused ultrasound (HIFU) ablation for patients with diffuse adenomyosis. This was a retrospective cohort study. The data was collected from 417 symptomatic adenomyosis patients who underwent ultrasound-guided HIFU between January 2012 and December 2015 at 1st Affiliated Hospital of Chongqing Medical University, Chongqing, China. Among them were 260 patients with diffuse adenomyosis (Group D) and 157 patients with focal adenomyosis (Group F). All patients underwent contrast-enhanced magnetic resonance imaging (MRI) one week before and the day after HIFU treatment. Successful treatment with HIFU was measured by the non-perfused volume ratio (NPVR). Intraprocedural and postprocedural adverse effects and complications were recorded to assess the safety of the procedure. Patients were followed-up for three months post-treatment. Complications were given a grade A through F according to the SIR Standards. All patients successfully completed the procedure, non-perfused regions appeared in 415 (99.5%) patients. The non-perfused volume ratio (NPVR) of Group D was significantly lower than that of Group F (P<0.05). During the procedure, the odds ratio of skin-burning pain was 1.7 (OR=1.617, 95% CI: 1.103-2.532), when comparing Group D with Group F, while the odds ratio of inguinal pain was equal to 2.0 (OR=2.038, 95% CI: 1.161-3.580), when Group F was compared to Group D. 97 patients (23.3%) received nominal therapy due to complications ([Society of interventional radiology, SIR]-B grade), among them, there were 62 cases (23.8%) in Group D and 35 cases (22.3%) in Group F. No significant difference was found between the two groups (P>0.05) and neither of the reported complications of SIR-C-SIR-F occurred within the two groups. Based on our results, ultrasound-guided HIFU is safe for the treatment of diffuse adenomyosis, and controlling the ablation zone is crucial to ensure patients' safety. Copyright © 2016 Elsevier

  19. Central venous catheter integrity during mechanical power injection of iodinated contrast medium.

    PubMed

    Macha, Douglas B; Nelson, Rendon C; Howle, Laurens E; Hollingsworth, John W; Schindera, Sebastian T

    2009-12-01

    To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

  20. A novel ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  1. Left ventricular lead placement in the latest activated region guided by coronary venous electroanatomic mapping.

    PubMed

    Rad, Masih Mafi; Blaauw, Yuri; Dinh, Trang; Pison, Laurent; Crijns, Harry J; Prinzen, Frits W; Vernooy, Kevin

    2015-01-01

    Left ventricular (LV) lead placement in the latest activated region is an important determinant of response to cardiac resynchronization therapy (CRT). We investigated the feasibility of coronary venous electroanatomic mapping (EAM) to guide LV lead placement to the latest activated region. Twenty-five consecutive CRT candidates with left bundle-branch block underwent intra-procedural coronary venous EAM using EnSite NavX. A guidewire was used to map the coronary veins during intrinsic activation, and to test for phrenic nerve stimulation (PNS). The latest activated region, defined as the region with an electrical delay >75% of total QRS duration, was located anterolaterally in 18 (basal, n = 10; mid, n = 8) and inferolaterally in 6 (basal, n = 3; mid, n = 3). In one patient, identification of the latest activated region was impeded by limited coronary venous anatomy. In patients with >1 target vein (n = 12), the anatomically targeted inferolateral vein was rarely the vein with maximal electrical delay (n = 3). A concordant LV lead position was achieved in 18 of 25 patients. In six patients, this was hampered by PNS (n = 4), lead instability (n = 1), and coronary vein stenosis (n = 1). Coronary venous EAM can be used intraprocedurally to guide LV lead placement to the latest activated region free of PNS. This approach especially contributes to optimization of LV lead electrical delay in patients with multiple target veins. Conventional anatomical LV lead placement strategy does not target the vein with maximal electrical delay in many of these patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  2. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    PubMed Central

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  3. Ultrasound-guided injection for plantar fasciitis: A brief review

    PubMed Central

    Nair, AS; Sahoo, RK

    2016-01-01

    Plantar fasciitis (PF) is a distressing condition experienced by many patients. Although self-limiting, it tends to become a chronic ailment if the precipitating factors are not addressed. One of the modality of treating PF is intra-lesional corticosteroid injection. This was done using palpation technique earlier but nowadays many specialists use ultrasound (US) imaging as a guide to give injection accurately instead of inadvertently damaging the plantar fascia or injecting into surrounding soft tissue, both of which can have serious implications. We did a literature search in Medline, Scopus, and Embase databases to find out articles describing US-guided corticosteroid injection for treating PF and whether guided injection was effective than injection given by palpation. PMID:27833490

  4. Is routine ultrasound guidance for central line placement beneficial? A prospective analysis.

    PubMed

    Martin, Matthew J; Husain, Farah A; Piesman, Michael; Mullenix, Philip S; Steele, Scott R; Andersen, Charles A; Giacoppe, George N

    2004-01-01

    Portable ultrasound devices have become more readily available in the intensive care unit setting, but their utility outside of controlled trials remains unproven. We sought to determine how the availability of ultrasound guidance affected the types and number of complications during central line placement. Review of a prospectively maintained database in a 20-bed combined intensive care unit. Procedure notes from all attempts at internal jugular vein access from 1996 to 2001 were recorded, and selected patient records were reviewed. Ultrasound guidance was available beginning in March 1998. From 1996 to 2001, there were 484 documented attempts at internal jugular central line placement. Most procedures (83%) were performed by first- or second-year residents. During this period, there were 47 complications for an overall complication rate of 10%. These included 1 pneumothorax (2%), 6 carotid punctures (13%), 2 hematomas (4%), and 34 unsuccessful attempts (72%). There was no significant difference in age, sex, body-mass index, or intubation status between those with and without complications or between the ultrasound and anatomic landmark groups. Ultrasound was used in 179 (37%) attempts. The overall complication rate with ultrasound was 11% versus 9% using anatomic landmarks (p = NS). The complication rate prior to the availability of ultrasound was 15 of 114 attempts (13%) versus 32 of 370 attempts (9%) after the introduction of ultrasound in our intensive care unit (p = NS). Analysis of the 370 procedures performed since ultrasound became available demonstrated a complication rate of 11% with ultrasound guidance versus 6% without (p = 0.09). There was no significant difference in complication rates by resident year group or department (surgery vs. other). However, procedures performed after-hours (1800 to 0800) were associated with a 15% complication rate versus 6% for procedures performed during the workday (p < 0.05). The availability and use of ultrasound

  5. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walser, Eric M., E-mail: walser.eric@mayo.edu

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist ofmore » catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.« less

  6. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algin, Oktay, E-mail: droktayalgin@gmail.com; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-02-15

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improvedmore » clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.« less

  7. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.

    PubMed

    Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki

    2017-03-01

    The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    PubMed

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  9. An ultrasound-guided fluorescence tomography system: design and specification

    NASA Astrophysics Data System (ADS)

    D'Souza, Alisha V.; Flynn, Brendan P.; Kanick, Stephen C.; Torosean, Sason; Davis, Scott C.; Maytin, Edward V.; Hasan, Tayyaba; Pogue, Brian W.

    2013-03-01

    An ultrasound-guided fluorescence molecular tomography system is under development for in vivo quantification of Protoporphyrin IX (PpIX) during Aminolevulinic Acid - Photodynamic Therapy (ALA-PDT) of Basal Cell Carcinoma. The system is designed to combine fiber-based spectral sampling of PPIX fluorescence emission with co-registered ultrasound images to quantify local fluorophore concentration. A single white light source is used to provide an estimate of the bulk optical properties of tissue. Optical data is obtained by sequential illumination of a 633nm laser source at 4 linear locations with parallel detection at 5 locations interspersed between the sources. Tissue regions from segmented ultrasound images, optical boundary data, white light-informed optical properties and diffusion theory are used to estimate the fluorophore concentration in these regions. Our system and methods allow interrogation of both superficial and deep tissue locations up to PpIX concentrations of 0.025ug/ml.

  10. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial)

    PubMed Central

    2011-01-01

    Background Breast-conserving surgery for breast cancer was developed as a method to preserve healthy breast tissue, thereby improving cosmetic outcomes. Thus far, the primary aim of breast-conserving surgery has been the achievement of tumour-free resection margins and prevention of local recurrence, whereas the cosmetic outcome has been considered less important. Large studies have reported poor cosmetic outcomes in 20-40% of patients after breast-conserving surgery, with the volume of the resected breast tissue being the major determinant. There is clear evidence for the efficacy of ultrasonography in the resection of nonpalpable tumours. Surgical resection of palpable breast cancer is performed with guidance by intra-operative palpation. These palpation-guided excisions often result in an unnecessarily wide resection of adjacent healthy breast tissue, while the rate of tumour-involved resection margins is still high. It is hypothesised that the use of intra-operative ultrasonography in the excision of palpable breast cancer will improve the ability to spare healthy breast tissue while maintaining or even improving the oncological margin status. The aim of this study is to compare ultrasound-guided surgery for palpable tumours with the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumour-free margins, cosmetic outcomes and quality of life. Methods/design In this prospective multicentre randomised controlled clinical trial, 120 women who have been diagnosed with palpable early-stage (T1-2N0-1) primary invasive breast cancer and deemed suitable for breast-conserving surgery will be randomised between ultrasound-guided surgery and palpation-guided surgery. With this sample size, an expected 20% reduction of resected breast tissue and an 18% difference in tumour-free margins can be detected with a power of 80%. Secondary endpoints include cosmetic outcomes and quality of life. The rationale, study

  11. Magnetic resonance guided high-intensity focused ultrasound ablation of musculoskeletal tumors

    PubMed Central

    Avedian, Raffi S.; Gold, Garry; Ghanouni, Pejman; Pauly, Kim Butts

    2015-01-01

    This article reviews the fundamental principles and clinical experimental uses of magnetic resonance guided high-intensity focused ultrasound (MRgHIFU) ablation of musculoskeletal tumors. MRgHIFU is a noninvasive treatment modality that takes advantage of the ability of magnetic resonance to measure tissue temperature and uses this technology to guide high-intensity focused ultrasound waves to a specific focus within the human body that results in heat generation and complete thermal necrosis of the targeted tissue. Adjacent normal tissues are spared because of the accurate delivery of thermal energy, as well as, local blood perfusion that provides a cooling effect. MRgHIFU is approved by the Food and Drug Administration for the treatment of uterine fibroids and is used on an experimental basis to treat breast, prostate, liver, bone, and brain tumors. PMID:26120376

  12. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated

  13. Combined Ultrasound and MR Imaging to Guide Focused Ultrasound Therapies in the Brain

    PubMed Central

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-01-01

    Purpose Several emerging therapies with potential for use in the brain harness effects produced by acoustic cavitation – the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength, and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. Materials and Methods We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. Results The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. Conclusion While preliminary, these data clearly demonstrate, for the first time, that is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate it will also prove to

  14. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    NASA Astrophysics Data System (ADS)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  15. Novel ultrasound-responsive chitosan/perfluorohexane nanodroplets for image-guided smart delivery of an anticancer agent: Curcumin.

    PubMed

    Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid

    2017-05-01

    Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. A review of randomised controlled trials comparing ultrasound-guided foam sclerotherapy with endothermal ablation for the treatment of great saphenous varicose veins.

    PubMed

    Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W

    2016-05-01

    The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author

  17. Does the preference of peripheral versus central venous access in peripheral blood stem cell collection/yield change stem cell kinetics in autologous stem cell transplantation?

    PubMed

    Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi

    2016-02-01

    Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. A technical report on ultrasound-guided scapulocostal syndrome injection.

    PubMed

    McCarthy, C; Harmon, D

    2016-08-01

    We describe a case report and technique for using an ultrasound scanner and a linear transducer to guide serratus posterior superior (SPS) muscle injection. A 43-year-old female presented with chronic pain centered under the right upper portion of her scapula impacting her activities of daily living. For the ultrasound-guided SPS muscle injection, the patient was placed in the prone position. The transducer was oriented in a transverse orientation at the level of the C6-T1 vertebrae. Here the SPS muscle attaches to the lower portion of the ligament nuchae and the intervening interspinous ligaments. The muscle fibers run inferiorly and laterally to attach to the 2nd-5th ribs which were identified along with the lateral portion of the serratus posterior superior muscle which is covered by the scapula. Real-time imaging was used to direct a spinal needle into the trigger points of the SPS muscle, where solution was injected under direct vision. The patient's pain symptoms improved significantly. Serratus posterior superior injection can confirm a diagnosis of scapulocostal syndrome and be therapeutically beneficial.

  19. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    PubMed

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7 < 2.6, 1.6 < 4.0, 3.5 < 5.8, 3.6 < 5.2, 3.2 < 4.2, 1.3 < 2.0), and a higher patient satisfaction score at 6, 12, 18, 24, and 36 h post-operatively than group 2 (7.8 > 6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p < 0.001), and the mean size of rebound pain was smaller in group 1 than that in group 2 (2.5 > 4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier

  20. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  1. Bilateral Pneumothoraces Following Central Venous Cannulation

    PubMed Central

    Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.

    2009-01-01

    We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax. PMID:19901997

  2. Air embolism after central venous catheterization.

    PubMed

    Kashuk, J L; Penn, I

    1984-09-01

    Air embolism--the most dangerous complication of central venous catheterization--may occur in several ways. The most frequent is from disconnection of the catheter from the related intravenous tubing. An embolism may present with a sucking sound, tachypnea, air hunger, wheezing, hypotension and a "mill wheel" murmur. A later manifestation is severe pulmonary edema. In a review of 24 patients, the mortality was 50 per cent. Among the survivors, five (42 per cent) had neurologic damage. Immediate treatment includes placing the patient in the left lateral and Trendelenberg positions, administration of oxygen and aspiration of air from the heart. Cardiac massage and emergency cardiopulmonary bypass may be necessary. Most instances can be prevented by inserting the cannula with the patient in the Trendelenberg position, occluding the cannula hub except briefly while the catheter is inserted, fixation of the catheter hub to its connections and occlusive dressing over the track after removal of the catheter.

  3. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    PubMed

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  4. Clinical evaluation of the use of an intracardiac electrocardiogram to guide the tip positioning of peripherally inserted central catheters.

    PubMed

    Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang

    2016-06-01

    The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.

  5. [Central venous catheter-related infections in critically ill patients].

    PubMed

    Diener, J R; Coutinho, M S; Zoccoli, C M

    1996-01-01

    To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.

  6. Fecal Impaction Causing Pelvic Venous Compression and Edema.

    PubMed

    Naramore, Sara; Aziz, Faisal; Alexander, Chandran Paul; Methratta, Sosamma; Cilley, Robert; Rocourt, Dorothy

    2015-09-28

    Chronic constipation is a common condition which may result in fecal impaction. A 13-year-old male with chronic constipation and encopresis presented with fecal impaction for three weeks. The impaction caused abdominal pain, distension, encopresis, and decreased oral intake. He was found in severe distress with non-pitting edema of his feet and ankles along with perineal edema. The pedal edema worsened after receiving a fluid bolus, so concern arose for venous compression or a thrombus. A Duplex Ultrasound demonstrated changes in the venous waveforms of the bilateral external iliac and common femoral veins without thrombosis. Manual disimpaction and polyethylene glycol 3350 with electrolytes resolved the pedal and perineal edema. Four months later, he had soft bowel movements without recurrence of the edema. A repeat Duplex Ultrasound was normal. We present a child in whom severe fecal impaction caused pelvic venous compression resulting in bilateral pedal and perineal edema.

  7. Ultrasound-guided medical thoracoscopy in the absence of pleural effusion.

    PubMed

    Marchetti, Giampietro; Valsecchi, Alberto; Indellicati, Davide; Arondi, Sabrina; Trigiani, Marco; Pinelli, Valentina

    2015-04-01

    Medical thoracoscopy (MT) is a diagnostic and therapeutic procedure that permits the study of the pleural space. The presence of pleural adhesions is the most important contraindication to performing MT. Lesions of the pleura in absence of pleural effusion are usually studied in video-assisted thoracoscopic surgery (VATS) with preoperative ultrasound evaluation. No data are available about ultrasound-guided MT in the absence of pleural effusion. From January 2007 to June 2013, 622 consecutive MTs were performed under ultrasound guidance without inducing a pneumothorax. A retrospective cohort of 29 patients affected by pleural diseases without fluid was reviewed. The fifth or sixth intercostal spaces along the midaxillary line with a good echographic "sliding sign" and normal appearance of the pleural line were chosen as the entry site. The pleural cavity was explored, and biopsies were performed. The mean age of the patient cohort was 62.8 years; there were 20 male patients and nine female patients. Pleural adherences were avoided, and adequate number of pleural biopsies were performed. No parenchymal lung injuries, bleeding, or hematoma occurred. Seventeen patients had a completely free pleural cavity, four patients had a single pleural adhesion, and eight had multiple pleural adhesions; in all cases, however, endoscopic exploration was possible and biopsy specimens were adequate. The most frequent histopathologic diagnosis was malignant pleural mesothelioma. We have shown that thoracic ultrasound accurately identifies intrathoracic adhesions and, in experienced hands, can guide MT access, replacing the VATS approach, even in the complete absence of pleural effusion.

  8. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with

  9. Videothoracoscopic management of a perforated central vein and pleura after ultrasound-guided internal jugular vein cannulation: a case report

    PubMed Central

    Kim, Jeong-Eun; Jeon, Joon-Pyo; Kim, Yongsuk; Jeong, Su Ah

    2014-01-01

    A 23-year-old male underwent a left internal jugular vein catheterization during extended surgery for treatment of multiple fractures due to a traffic accident. Although the catheterization was performed under ultrasound (US) guidance, iatrogenic perforation of the central vein and pleura occurred. The catheter was removed, and the perforated site was addressed under thoracoscopy rather than an open thoracotomy. This case suggests that using US does not completely guarantee a complication-free outcome, and that catheter placement should be carefully confirmed. In addition, this case suggests that thoracoscopy may be an ideal method of resolving a perforation of the central vein and pleura. PMID:24851167

  10. Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity

    PubMed Central

    Sconfienza, L.M.; Perrone, N.; Lacelli, F.; Lentino, C.; Serafini, G.

    2008-01-01

    Purpose Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. Method and materials The ultrasound-guided technique for BTX-A injection was used on 10 patients. The needle was inserted into the muscle belly at an angle of 45° along the longitudinal axis of the muscle when allowed by patient's condition. Results In all cases, the iliopsoas muscle was easily identified and both the iliac and psoas components were assessed. Introduction of the needle and drug injection were entirely carried out under ultrasonographic guidance. The procedure was successful in all patients, even in those with a high-grade spasticity, and general anesthesia was not required. Conclusions This ultrasound-guided technique allows accurate guidance for the injection of BTX-A, and it can be considered as an alternate supportive therapy in patients with spasticity and dystonia. PMID:23396653

  11. Propogation loss with frequency of ultrasound guided waves in a composite metal-honeycomb structure

    NASA Astrophysics Data System (ADS)

    Saxena, Indu F.; Baid, Harsh K.; Guzman, Narciso; Kempen, Lothar U.; Mal, Ajit

    2009-05-01

    Non-destructive testing of critical structural components is time consuming, while necessary for maintaining safe operation. Large aerospace structures, such as the vertical stabilizers of aircraft undergo inspection at regular intervals for damage diagnostics. However, conventional techniques for damage detection and identification before repair can be scheduled are conducted off-line and therefore can take weeks. The use of guided ultrasound waves is being investigated to expedite damage detection in composites. We measure the frequency dependent loss of ultrasonic guided waves for a structure comprising a boron-nitride composite skin sandwiching an aluminum honeycomb. A wide range of ultrasound frequencies propagate as measured using PZTs, with the lowest attenuation observed about 200-250 kHz. These measurements are confirmed using optical fiber Bragg grating arrays used as ultrasound transducers.

  12. Feasibility of ultrasound-guided epidural access at the lumbo-sacral space in dogs.

    PubMed

    Liotta, Annalisa; Busoni, Valeria; Carrozzo, Maria Valentina; Sandersen, Charlotte; Gabriel, Annick; Bolen, Géraldine

    2015-01-01

    Epidural injections are commonly performed blindly in veterinary medicine. The aims of this study were to describe the lumbosacral ultrasonographic anatomy and to assess the feasibility of an ultrasound-guided epidural injection technique in dogs. A cross sectional anatomic atlas of the lumbosacral region and ex vivo ultrasound images were obtained in two cadavers to describe the ultrasound anatomy and to identify the landmarks. Sixteen normal weight canine cadavers were used to establish two variations of the technique for direct ultrasound-guided injection, using spinal needles or epidural catheters. The technique was finally performed in two normal weight cadavers, in two overweight cadavers and in five live dogs with radiographic abnormalities resulting of the lumbosacral spine. Contrast medium was injected and CT was used to assess the success of the injection. The anatomic landmarks to carry out the procedure were the seventh lumbar vertebra, the iliac wings, and the first sacral vertebra. The target for directing the needle was the trapezoid-shaped echogenic zone between the contiguous articular facets of the lumbosacral vertebral canal visualized in a parasagittal plane. The spinal needle or epidural catheter was inserted in a 45° craniodorsal-caudoventral direction through the subcutaneous tissue and the interarcuate ligament until reaching the epidural space. CT examination confirmed the presence of contrast medium in the epidural space in 25/25 dogs, although a variable contamination of the subarachnoid space was also noted. Findings indicated that this ultrasound-guided epidural injection technique is feasible for normal weight and overweight dogs, with and without radiographic abnormalities of the spine. © 2014 American College of Veterinary Radiology.

  13. MR-guided focused ultrasound robot for performing experiments on large animals

    NASA Astrophysics Data System (ADS)

    Mylonas, N.; Damianou, C.

    2011-09-01

    Introduction: In this paper an experimental MRI-guided focused ultrasound robot for large animals is presented. Materials and methods: A single element spherically focused transducer of 4 cm diameter, focusing at 10 cm and operating at 1 MHz was used. A positioning device was developed in order to scan the ultrasound transducer for performing MR-guided focused ultrasound experiments in large animals such as pig, sheep and dog. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, Acrylonitrile Butadiene Styrene (ABS) plastic, brass screws, and brass pulleys. The system is manufactured automatically using a rapid prototyping system. Results: The system was tested successfully in a number of animals for various tasks (creation of single lesions, creation of overlapping lesions, and MR compatibility). Conclusions: A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can be via a lateral or superior-inferior approach. This system has the potential to be marketed as a cost effective solution for performing experiments in small and large animals.

  14. Ultrasound-guided percutaneous tracheostomy in critically ill obese patients

    PubMed Central

    2012-01-01

    Introduction The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Methods Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m2. The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). Results The median BMIs were 34 kg/m2 (32-38) in the obese patient group and 25 kg/m2 (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. Conclusions This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. Trial registration ClinicalTrials.gov: NCT01502657. PMID:22390815

  15. Ultrasound-guided percutaneous tracheostomy in critically ill obese patients.

    PubMed

    Guinot, Pierre-Grégoire; Zogheib, Elie; Petiot, Sandra; Marienne, Jean-Pierre; Guerin, Anne-Marie; Monet, Pauline; Zaatar, Rody; Dupont, Hervé

    2012-12-12

    The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m². The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). The median BMIs were 34 kg/m² (32-38) in the obese patient group and 25 kg/m² (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. ClinicalTrials.gov: NCT01502657.

  16. New platform for evaluating ultrasound-guided interventional technologies

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.

    2016-04-01

    Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.

  17. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    PubMed

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart

  18. Robotic active positioning for magnetic resonance-guided high-intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Xiao, Xu; Huang, Zhihong; Volovick, Alexander; Melzer, Andreas

    2012-11-01

    Magnetic resonance (MR) guided High-intensity focused ultrasound (HIFU) is a noninvasive method producing thermal necrosis and cavitation at the position of tumors with high accuracy. Because the typical size of the high-intensity focused ultrasound focus are much smaller than the targeted tumor or other tissues, multiple sonications and focus repositioning become necessary for HIFU treatment. In order to reach a much wider range, manual repositioning or using MR compatible mechanical actuators could be used. The repositioning technique is a time consuming procedure because it needs a series of MR imaging to detect the transducer and markers preplaced on the mechanical devices. We combined an active tracking technique into the MR guided HIFU system. In this work, the robotic system used is the MR-compatible robotics from InnoMotion{trade mark, serif} (IBSMM, Engineering spol. s r.o. / Ltd, Czech) which is originally designed for MR-guided needle biopsy. The precision and positioning speed of the combined robotic HIFU system are evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the HIFU treatment to operate in a larger spatial range and with a faster speed.

  19. Outcomes of Ultrasound-Guided Thrombin Injection of Nongroin Arterial Pseudoaneurysms.

    PubMed

    Valesano, Johnathan C; Schmitz, John J; Kurup, A Nicholas; Schmit, Grant D; Moynagh, Michael R; Atwell, Thomas D; Lewis, Bradley D; Lee, Robert A; Callstrom, Matthew R

    2017-08-01

    To evaluate success and complication rates of percutaneous ultrasound-guided thrombin injection of nongroin pseudoaneurysms (PSAs). Retrospective review of a prospectively maintained institutional database yielded 39 cases of arterial PSAs occurring at nongroin sites that were treated with percutaneous ultrasound-guided thrombin injection between 2000 and 2016 (average patient age 69.2 y ± 14.0). Of PSAs, 74.4% (29/39) arose in the upper extremities, and 92.3% (36/39) were iatrogenic. The brachial artery was the most commonly affected vessel (51.3% [20/39]), and arterial access was the most common cause (56.4% [22/39]). Average overall PSA size was 2.4 cm (range, 0.5-7.2 cm); average amount of thrombin injected was 320 IU (range, 50-2,000 IU). Technical success was defined as absence of flow within the PSA immediately after thrombin injection. Treatment success was defined as sustained thrombosis on follow-up imaging obtained at 1-3 days after treatment. Technical and treatment success rates of thrombin injections were 100% (39/39) and 84.8% (28/33), respectively. Longer term follow-up imaging (average 71 d; range, 12-201 d) was available for 7 of the treatment successes with 100% (7/7) showing sustained thrombosis. Comparing treatment successes and failures, there was no significant difference in average PSA size (2.3 cm vs 2.0 cm, P = .51) or average amount of thrombin injected (360 IU vs 180 IU, P = .14). There were no complications. Ultrasound-guided thrombin injection is a safe, efficacious treatment option for PSAs arising in nongroin locations. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  20. Guiding tissue regeneration with ultrasound in vitro and in vivo

    NASA Astrophysics Data System (ADS)

    Dalecki, Diane; Comeau, Eric S.; Raeman, Carol H.; Child, Sally Z.; Hobbs, Laura; Hocking, Denise C.

    2015-05-01

    Developing new technologies that enable the repair or replacement of injured or diseased tissues is a major focus of regenerative medicine. This paper will discuss three ultrasound technologies under development in our laboratories to guide tissue regeneration both in vitro and in vivo. A critical obstacle in tissue engineering is the need for rapid and effective tissue vascularization strategies. To address this challenge, we are developing acoustic patterning techniques for microvascular tissue engineering. Acoustic radiation forces associated with ultrasound standing wave fields provide a rapid, non-invasive approach to spatially pattern cells in three dimensions without affecting cell viability. Acoustic patterning of endothelial cells leads to the rapid formation of microvascular networks throughout the volumes of three-dimensional hydrogels, and the morphology of the resultant microvessel networks can be controlled by design of the ultrasound field. A second technology under development uses ultrasound to noninvasively control the microstructure of collagen fibers within engineered tissues. The microstructure of extracellular matrix proteins provides signals that direct cell functions critical to tissue regeneration. Thus, controlling collagen microfiber structure with ultrasound provides a noninvasive approach to regulate the mechanical properties of biomaterials and control cellular responses. The third technology employs therapeutic ultrasound to enhance the healing of chronic wounds. Recent studies demonstrate increased granulation tissue thickness and collagen deposition in murine dermal wounds exposed to pulsed ultrasound. In summary, ultrasound technologies offer noninvasive approaches to control cell behaviors and extracellular matrix organization and thus hold great promise to advance tissue regeneration in vitro and in vivo.

  1. Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.

    PubMed

    Ajmal, Muhammad; Power, Susan; Smith, Tim; Shorten, George D

    2011-02-01

    To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting. Pilot prospective observational study. Orthopedic operating room of a regional trauma hospital. 15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire. The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion. Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  3. Risk factors, management and primary prevention of thrombotic complications related to the use of central venous catheters.

    PubMed

    Linnemann, Birgit; Lindhoff-Last, Edelgard

    2012-09-01

    An adequate vascular access is of importance for the treatment of patients with cancer and complex illnesses in the intensive, perioperative or palliative care setting. Deep vein thrombosis and thrombotic occlusion are the most common complications attributed to central venous catheters in short-term and, especially, in long-term use. In this review we will focus on the risk factors, management and prevention strategies of catheter-related thrombosis and occlusion. Due to the lack of randomised controlled trials, there is still controversy about the optimal treatment of catheter-related thrombotic complications, and therapy has been widely adopted using the evidence concerning lower extremity deep vein thrombosis. Given the increasing use of central venous catheters in patients that require long-term intravenous therapy, the problem of upper extremity deep venous thrombosis can be expected to increase in the future. We provide data for establishing a more uniform strategy for preventing, diagnosing and treating catheter-related thrombotic complications.

  4. Fecal Impaction Causing Pelvic Venous Compression and Edema

    PubMed Central

    Naramore, Sara; Aziz, Faisal; Alexander, Chandran Paul; Methratta, Sosamma; Cilley, Robert; Rocourt, Dorothy

    2015-01-01

    Chronic constipation is a common condition which may result in fecal impaction. A 13-year-old male with chronic constipation and encopresis presented with fecal impaction for three weeks. The impaction caused abdominal pain, distension, encopresis, and decreased oral intake. He was found in severe distress with non-pitting edema of his feet and ankles along with perineal edema. The pedal edema worsened after receiving a fluid bolus, so concern arose for venous compression or a thrombus. A Duplex Ultrasound demonstrated changes in the venous waveforms of the bilateral external iliac and common femoral veins without thrombosis. Manual disimpaction and polyethylene glycol 3350 with electrolytes resolved the pedal and perineal edema. Four months later, he had soft bowel movements without recurrence of the edema. A repeat Duplex Ultrasound was normal. We present a child in whom severe fecal impaction caused pelvic venous compression resulting in bilateral pedal and perineal edema. PMID:26500749

  5. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    NASA Astrophysics Data System (ADS)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  6. Centers for Disease Control and Prevention guidelines for preventing central venous catheter-related infection: results of a knowledge test among 3405 European intensive care nurses.

    PubMed

    Labeau, Sonia O; Vandijck, Dominique M; Rello, Jordi; Adam, Sheila; Rosa, Ana; Wenisch, Christoph; Bäckman, Carl; Agbaht, Kemal; Csomos, Akos; Seha, Myriam; Dimopoulos, George; Vandewoude, Koenraad H; Blot, Stijn I

    2009-01-01

    To determine European intensive care unit (ICU) nurses' knowledge of guidelines for preventing central venous catheter-related infection from the Centers for Disease Control and Prevention. Multicountry survey (October 2006-March 2007). Twenty-two European countries. ICU nurses. Using a validated multiple-choice test, knowledge of ten recommendations for central venous catheter-related infection prevention was evaluated (one point per question) and assessed in relation to participants' gender, ICU experience, number of ICU beds, and acquisition of a specialized ICU qualification. We collected 3405 questionnaires (70.9% response rate); mean test score was 44.4%. Fifty-six percent knew that central venous catheters should be replaced on indication only, and 74% knew this also concerns replacement over a guidewire. Replacing pressure transducers and tubing every 4 days, and using coated devices in patients requiring a central venous catheter >5 days in settings with high infection rates only were recognized as recommended by 53% and 31%, respectively. Central venous catheters dressings in general are known to be changed on indication and at least once weekly by 43%, and 26% recognized that both polyurethane and gauze dressings are recommended. Only 14% checked 2% aqueous chlorhexidine as the recommended disinfection solution; 30% knew antibiotic ointments are not recommended because they trigger resistance. Replacing administration sets within 24 hrs after administering lipid emulsions was recognized as recommended by 90%, but only 26% knew sets should be replaced every 96 hrs when administering neither lipid emulsions nor blood products. Professional seniority and number of ICU beds showed to be independently associated with better test scores. Opportunities exist to optimize knowledge of central venous catheter-related infection prevention among European ICU nurses. We recommend including central venous catheter-related infection prevention guidelines in educational

  7. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    PubMed

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  8. Comparison of ultrasound-guided supraclavicular block according to the various volumes of local anesthetic

    PubMed Central

    Kim, Seok Kon; Kang, Bong Jin; Kwon, Min A; Song, Jae Gyok; Jeon, Soo Mi

    2013-01-01

    Background The ultrasound guidance in regional nerve blocks has recently been introduced and gaining popularity. Ultrasound-guided supraclavicular block has many advantages including the higher success rate, faster onset time, and fewer complications. The aim of this study was to examine the clinical data according to the varied volume of local anesthetics in the ultrasound-guided supraclavicular block. Methods One hundred twenty patients were randomized into four groups, according to the local anesthetic volume used: Group 35 (n = 30), Group 30 (n = 30), Group 25 (n = 30), and Group 20 (n = 30). Supraclavicular blocks were performed with 1% mepivacaine 35 ml, 30 ml, 25 ml, and 20 ml, respectively. The success rate, onset time, and complications were checked and evaluated. Results The success rate (66.7%) was lower in Group 20 than that of Group 35 (96.7%) (P < 0.05). The average onset times of Group 35, Group 30, Group 25, and Group 20 were 14.3 ± 6.9 min, 13.6 ± 4.5 min, 16.7 ± 4.6 min, and 16.5 ± 3.7 min, respectively. There were no significant differences. Horner's syndrome was higher in Group 35 (P < 0.05). Conclusions In conclusion, we achieved 90% success rate with 30 ml of 1% mepivacaine. Therefore, we suggest 30 ml of local anesthetic volume for ultrasound-guided supraclavicular block. PMID:23814648

  9. Ultrasound Monitoring of Jugular Venous Pulse during Space Missions: Proof of Concept.

    PubMed

    Zamboni, Paolo; Sisini, Francesco; Menegatti, Erica; Taibi, Angelo; Gadda, Giacomo; Tavoni, Valentina; Malagoni, Anna Maria; Tessari, Mirko; Gianesini, Sergio; Gambaccini, Mauro

    2018-03-01

    The jugular venous pulse (JVP) is one of the main parameters of cardiac function and is used by cardiologists in diagnosing heart failure. Its waveform comprises three positive waves (a, c and v) and two negative waves (x and y). Recently, it was found that JVP can be extrapolated from an ultrasound (US) video recording of the internal jugular vein (IJV), suggesting its application in space missions, on which US scanners are already widely used. To date, the feasibility of assessing JVP in microgravity (microG) has not been investigated. To verify the feasibility of JVP assessment in microG, we tested a protocol of self-performed B-mode ultrasound on the International Space Station (ISS). The protocol consisted of a video recording of IJV synchronized with electrocardiogram that produces a cross-sectional area time trace (JVP trace) (in cm 2 ). The scans were acquired in six experimental sessions; two pre-flight (BDC1 and -2), two in space (ISS1 and -2) and two post-flight (Houston PF1, Cologne PF2). We measured the mean and standard deviation of the JVP waves and the phase relationship between such waves and P and T waves on the electrocardiogram. We verified that such parameters had the same accuracy on Earth as they did under microG, and we compared their values. The sensitivity, specificity and accuracy of JVP trace in microgravity are higher than those on Earth. The sequence of (a, c, and v) ascents and (x and y) descents along the cardiac cycle in microG is the same as that on Earth. The cause-and-effect relationship between the P and T waves on the electrocardiogram and a and v waves, respectively, of JVP is also confirmed in microG. Our experiment indicated the feasibility of deriving a JVP trace from a B-mode US examination self-performed by an astronaut in microG. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  10. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2018-06-01

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  11. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  12. Treatment of Parkinson's disease in rats by Nrf2 transfection using MRI-guided focused ultrasound delivery of nanomicrobubbles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Ling; Cai, Xiaodong; Guo, Ruomi

    Parkinson's disease (PD) is a very common neurological disorder. However, effective therapy is lacking. Although the blood-brain-barrier (BBB) protects the brain, it prevents the delivery of about 90% of drugs and nucleotides into the brain, thereby hindering the development of gene therapy for PD. Magnetic resonance imaging (MRI)-guided focused ultrasound delivery of microbubbles enhances the delivery of gene therapy vectors across the BBB and improves transfection efficiency. In the present study, we delivered nuclear factor E2-related factor 2 (Nrf2, NFE2L2) contained in nanomicrobubbles into the substantia nigra of PD rats by MRI-guided focused ultrasound, and we examined the effect ofmore » Nrf2 over-expression in this animal model of PD. The rat model of PD was established by injecting 6-OHDA in the right substantia nigra stereotactically. Plasmids (pDC315 or pDC315/Nrf2) were loaded onto nanomicrobubbles, and then injected through the tail vein with the assistance of MRI-guided focused ultrasound. MRI-guided focused ultrasound delivery of nanomicrobubbles increased gene transfection efficiency. Furthermore, Nrf2 gene transfection reduced reactive oxygen species levels, thereby protecting neurons in the target region. - Highlights: • MRI-guided focused ultrasound enhances gene transfection into the brain of rats. • Increased Nrf2 expression protects neurons in the rat model of PD. • Nrf2 protects neurons in PD by inhibiting ROS production.« less

  13. Barriers and Facilitators to Central Venous Catheter Insertion: A Qualitative Study.

    PubMed

    Cameron, Kenzie A; Cohen, Elaine R; Hertz, Joelle R; Wayne, Diane B; Mitra, Debi; Barsuk, Jeffrey H

    2018-03-14

    The aims of the study were to identify perceived barriers and facilitators to central venous catheter (CVC) insertion among healthcare providers and to understand the extent to which an existing Simulation-Based Mastery Learning (SBML) program may address barriers and leverage facilitators. Providers participating in a CVC insertion SBML train-the-trainer program, in addition to intensive care unit nurse managers, were purposively sampled from Veterans Administration Medical Centers located in geographically diverse areas. We conducted semistructured interviews to assess perceptions of barriers and facilitators to CVC insertion. Deidentified transcripts were analyzed using a grounded theory approach and the constant comparative method. We subsequently mapped identified barriers and facilitators to our SBML curriculum to determine whether or not the curriculum addresses these factors. We interviewed 28 providers at six Veterans Administration Medical Centers, identifying the following five overarching factors of perceived barriers to CVC insertion: (1) equipment, (2) personnel/staff, (3) setting or organizational context, (4) patient or provider, and (5) time-related barriers. Three overarching factors of facilitators emerged: (1) equipment, (2) personnel, and (3) setting or organizational context facilitators. The SBML curriculum seems to address most identified barriers, while leveraging many facilitators; building on the commonly identified facilitator of nursing staff contribution by expanding the curriculum to explicitly include nurse involvement could improve team efficiency and organizational culture of safety. Many identified facilitators (e.g., ability to use ultrasound, personnel confidence/competence) were also identified as barriers. Evidence-based SBML programs have the potential to amplify these facilitators while addressing the barriers by providing an opportunity to practice and master CVC insertion skills.

  14. In-vivo ultrasound and photoacoustic image- guided photothermal cancer therapy using silica-coated gold nanorods.

    PubMed

    Kim, Seungsoo; Chen, Yun-Sheng; Luke, Geoffrey P; Emelianov, Stanislav Y

    2014-05-01

    In nanoparticle-augmented photothermal therapy, evaluating the delivery and spatial distribution of nanoparticles, followed by remote temperature mapping and monitoring, is essential to ensure the optimal therapeutic outcome. The utility of ultrasound and photoacoustic imaging to assist photothermal therapy has been previously demonstrated. Here, using a mouse xenograft tumor model, it is demonstrated in vivo that ultrasound-guided photoacoustic imaging can be used to plan the treatment and to guide the therapy. To evaluate nanoparticle delivery and spatial distribution, three-dimensional ultrasound and spectroscopic photoacoustic imaging of a mouse with a tumor was performed before and after intravenous injection of silica-coated gold nanorods. After injection and sufficient circulation of nanoparticles, photothermal therapy was performed for 5 min using an 808-nm continuous-wave laser. During the photothermal therapy, photoacoustic images were acquired continuously and used to measure the temperature changes within tissue. A heterogeneous distribution of temperature, which was spatially correlated with the measured distribution of nanoparticles, indicated that peak temperatures of 53°C were achieved in the tumor. An Arrhenius thermal damage model determined that this thermal deposition would result in significant cell death. The results of this study suggest that ultrasound and photoacoustic imaging can effectively guide photothermal therapy to achieve the desired thermal treatment.

  15. Reproducibility of Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Thermal Lesions in Minimally-Invasive Brain Surgery

    NASA Astrophysics Data System (ADS)

    Zahedi, Sulmaz

    This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.

  16. Comparison of catheter-related large vein thrombosis in centrally inserted versus peripherally inserted central venous lines in the neurological intensive care unit.

    PubMed

    Wilson, Thomas J; Stetler, William R; Fletcher, Jeffrey J

    2013-07-01

    To compare cumulative complication rates of peripherally (PICC) and centrally (CICVC) inserted central venous catheters, including catheter-related large vein thrombosis (CRLVT), central line-associated bloodstream infection (CLABSI), and line insertion-related complications in neurological intensive care patients. Retrospective cohort study and detailed chart review for 431 consecutive PICCs and 141 CICVCs placed in patients under neurological intensive care from March 2008 through February 2010. Cumulative incidence of CRLVT, CLABSI, and line insertion-related complications were compared between PICC and CICVC groups. Risk factors for CRLVT including mannitol therapy during dwell time, previous history of venous thromboembolism, surgery longer than 1h during dwell time, and line placement in a paretic arm were also compared between groups. During the study period, 431 unique PICCs were placed with cumulative incidence of symptomatic thrombosis of 8.4%, CLABSI 2.8%, and line insertion-related complications 0.0%. During the same period, 141 unique CICVCs were placed with cumulative incidence of symptomatic thrombosis of 1.4%, CLABSI 1.4%, and line insertion-related complications 0.7%. There was a statistically significant difference in CRLVT with no difference in CLABSI or line insertion-related complications. In neurological critical care patients, CICVCs appear to have a better risk profile compared to PICCs, with a decreased risk of CRLVT. As use of PICCs in critical care patients increases, a prospective randomized trial comparing PICCs and CICVCs in neurological critical care patients is necessary to assist in choosing the appropriate catheter and to minimize risks of morbidity and mortality associated with central venous access. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. A prospective study of central venous catheters placed in a tertiary care Emergency Department: indications for use, infectious complications, and natural history.

    PubMed

    Diaz, Katrina; Kelly, Sean G; Smith, Barbara; Malani, Preeti N; Younger, John G

    2012-02-01

    Despite successful efforts to improve overall central line-associated bloodstream infections (CLABSI) rates, little is known about CLABSI rates or even central venous catheter insertion practices in the Emergency Department. We sought to determine the baseline CLABSI rate for Emergency Department-inserted central venous catheters and to describe indications for placement, duration of use, and the natural history of these devices. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Transvaginal 3D Image-Guided High Intensity Focused Ultrasound Array

    NASA Astrophysics Data System (ADS)

    Held, Robert; Nguyen, Thuc Nghi; Vaezy, Shahram

    2005-03-01

    The goal of this project is to develop a transvaginal image-guided High Intensity Focused Ultrasound (HIFU) device using piezocomposite HIFU array technology, and commercially-available ultrasound imaging. Potential applications include treatment of uterine fibroids and abnormal uterine bleeding. The HIFU transducer was an annular phased array, with a focal length range of 30-60 mm, an elliptically-shaped aperture of 35×60 mm, and an operating frequency of 3 MHz. A pillow-shaped bag with water circulation will be used for coupling the HIFU energy into the tissue. An intra-cavity imaging probe (C9-5, Philips) was integrated with the HIFU array such that the focal axis of the HIFU transducer was within the image plane. The entire device will be covered by a gel-filled condom when inserted in the vaginal cavity. To control it, software packages were developed in the LabView programming environment. An imaging algorithm processed the ultrasound image to remove noise patterns due to the HIFU signal. The device will be equipped with a three-dimensional tracking system, using a six-degrees-of-freedom articulating arm. Necrotic lesions were produced in a tissue-mimicking phantom and a turkey breast sample for all focal lengths. Various HIFU doses allow various necrotic lesion shapes, including thin ellipsoidal, spherical, wide cylindrical, and teardrop-shaped. Software control of the device allows multiple foci to be activated sequentially for desired lesion patterns. Ultrasound imaging synchronization can be achieved using hardware signals obtained from the imaging system, or software signals determined empirically for various imaging probes. The image-guided HIFU device will provide a valuable tool in visualization of uterine fibroid tumors for the purposes of planning and subsequent HIFU treatment of the tumor, all in a 3D environment. The control system allows for various lesions of different shapes to be optimally positioned in the tumor to cover the entire tumor

  19. Percutaneous Embolization of Congenital Portosystemic Venous Fistula in an Infant with Down Syndrome

    PubMed Central

    Tanya Chun, Pattaraporn; Files, Matthew; Vo, Nghia; McAdams, Ryan M.

    2013-01-01

    Congenital intrahepatic portosystemic venous shunts are rare vascular malformations often associated with severe complications. We describe a term male infant with Down syndrome with high output heart failure secondary to a congenital arterial to portal venous fistula that was diagnosed by Doppler ultrasound. Percutaneous embolizations of the left hepatic vein, portal vein, and communicating fistulas were performed without complications, resulting in clinical improvement. A subsequent hepatic ultrasound demonstrated resolution of the pathologic fistulous communication and shunting effects. PMID:24171135

  20. Ultrasound-guided platelet-rich plasma injection for distal biceps tendinopathy.

    PubMed

    Barker, Scott L; Bell, Simon N; Connell, David; Coghlan, Jennifer A

    2015-04-01

    Distal biceps tendinopathy is an uncommon cause of elbow pain. The optimum treatment for cases refractory to conservative treatment is unclear. Platelet-rich plasma has been used successfully for other tendinopathies around the elbow. Six patients with clinical and radiological evidence of distal biceps tendinopathy underwent ultrasound-guided platelet-rich plasma (PRP) injection. Clinical examination findings, visual analogue score (VAS) for pain and Mayo Elbow Performance scores were recorded. The Mayo Elbow Performance Score improved from 68.3 (range 65 to 85) (fair function) to 95 (range 85 to 100) (excellent function). The VAS at rest improved from a mean of 2.25 (range 2 to 5) pre-injection to 0. The VAS with movement improved from a mean of 7.25 (range 5 to 8) pre-injection to 1.3 (range 0 to 2). No complications were noted. Ultrasound-guided PRP injection appears to be a safe and effective treatment for recalcitrant cases of distal biceps tendinopathy. Further investigation with a randomized controlled trial is needed to fully assess its efficacy.

  1. Ultrasound-guided platelet-rich plasma injection for distal biceps tendinopathy

    PubMed Central

    Bell, Simon N; Connell, David; Coghlan, Jennifer A

    2015-01-01

    Background Distal biceps tendinopathy is an uncommon cause of elbow pain. The optimum treatment for cases refractory to conservative treatment is unclear. Platelet-rich plasma has been used successfully for other tendinopathies around the elbow. Methods Six patients with clinical and radiological evidence of distal biceps tendinopathy underwent ultrasound-guided platelet-rich plasma (PRP) injection. Clinical examination findings, visual analogue score (VAS) for pain and Mayo Elbow Performance scores were recorded. Results The Mayo Elbow Performance Score improved from 68.3 (range 65 to 85) (fair function) to 95 (range 85 to 100) (excellent function). The VAS at rest improved from a mean of 2.25 (range 2 to 5) pre-injection to 0. The VAS with movement improved from a mean of 7.25 (range 5 to 8) pre-injection to 1.3 (range 0 to 2). No complications were noted. Discussion Ultrasound-guided PRP injection appears to be a safe and effective treatment for recalcitrant cases of distal biceps tendinopathy. Further investigation with a randomized controlled trial is needed to fully assess its efficacy. PMID:27582965

  2. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    PubMed Central

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  3. Nitroglycerine and patient position effect on central, hepatic and portal venous pressures during liver surgery.

    PubMed

    Sand, L; Lundin, S; Rizell, M; Wiklund, J; Stenqvist, O; Houltz, E

    2014-09-01

    To reduce blood loss during liver surgery, a low central venous pressure (CVP) is recommended. Nitroglycerine (NG) with its rapid onset and offset can be used to reduce CVP. In this study, the effect of NG on portal and hepatic venous pressures (PVP and HVP) in different body positions was assessed. Thirteen patients undergoing liver resection were studied. Cardiac output (CO), mean arterial pressure (MAP) and CVP were measured. PVP and HVP were measured using tip manometer catheters at baseline (BL) in horizontal position; during NG infusion, targeting a MAP of 60 mmHg, with NG infusion and the patient placed in 10 head-down position. NG infusion reduced HVP from 9.7 ± 2.4 to 7.2 ± 2.4, PVP from 12.3 ± 2.2 to 9.7 ± 3.0 and CVP from 9.8 ± 1.9 to 7.2 ± 2.1 mmHg at BL. Head-down tilt during ongoing NG resulted in increases in HVP to 8.2 ± 2.1, PVP to 10.7 ± 3 and CVP to 11 ± 1.9 mmHg. CO at BL was 6.3 ± 1.1, which was reduced by NG to 5.8 ± 1.2. Head-down tilt together with NG infusion restored CO to 6.3 ± 1.0 l/min. NG infusion leads to parallel reductions in CVP, HVP and PVP at horizontal body position. Thus, CVP can be used to guide NG dosage and fluid administration at horizontal position. NG infusion can be used to reduce HVP. Head-down tilt can be used during NG infusion to improve both blood pressure and CO without substantial increase in liver venous pressure. In head-down tilt, CVP dissociates from HVP and PVP. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    PubMed

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or

  5. Treatment of great auricular neuralgia with real-time ultrasound-guided great auricular nerve block

    PubMed Central

    Jeon, Younghoon; Kim, Saeyoung

    2017-01-01

    Abstract Rationale: The great auricular nerve can be damaged by the neck surgery, tumor, and long-time pressure on the neck. But, great auricular neuralgia is very rare condition. It was managed by several medication and landmark-based great auricular nerve block with poor prognosis. Patient concerns: A 25-year-old man presented with a pain in the left lateral neck and auricle. Diagnosis: He was diagnosed with great auricular neuralgia. Interventions: His pain was not reduced by medication. Therefore, the great auricular nerve block with local anesthetics and steroid was performed under ultrasound guidance. Outcomes: Ultrasound guided great auricular nerve block alleviated great auricular neuralgia. Lessons: This medication-resistant great auricular neuralgia was treated by the ultrasound guided great auricular nerve block with local anesthetic agent and steroid. Therefore, great auricular nerve block can be a good treatment option of medication resistant great auricular neuralgia. PMID:28328811

  6. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis.

    PubMed

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A; Quiles, Katherine G; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2018-01-01

    The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis.

  7. Comparison of the analgesic efficacy of ultrasound-guided rectus sheath block and local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children.

    PubMed

    Uchinami, Yuka; Sakuraya, Fumika; Tanaka, Nobuhiro; Hoshino, Koji; Mikami, Eri; Ishikawa, Taro; Fujii, Hitomi; Ishikawa, Takehiko; Morimoto, Yuji

    2017-05-01

    Ultrasound-guided rectus sheath block and local anesthetic infiltration are the standard options to improve postoperative pain for children undergoing surgery with a midline incision. However, there is no study comparing the effect of ultrasound-guided rectus sheath block with local anesthetic infiltration for children undergoing laparoscopic surgery. The aim of this trial was to compare the onset of ultrasound-guided rectus sheath block with that of local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children. We performed an observer-blinded, randomized, prospective trial. Enrolled patients were assigned to either an ultrasound-guided rectus sheath block group or a local anesthetic infiltration group. The ultrasound-guided rectus sheath block group (n = 17) received ultrasound-guided rectus sheath block with 0.2 ml·kg -1 of 0.375% ropivacaine per side in the posterior rectus sheath compartment. The local anesthetic infiltration group (n = 17) received local anesthetic infiltration with 0.2 ml·kg -1 of 0.75% ropivacaine. The Face, Legs, Activity, Cry, and Consolability (FLACC) pain scores were recorded at 0, 30, 60 min after arrival at the postanesthesia care unit. Of the 37 patients enrolled in this study, 34 completed the study protocol. A significant difference in the pain scale between the ultrasound-guided rectus sheath block group and local anesthetic infiltration group was found at 0 min (median: 0, interquartile range [IQR]: 0-1.5, vs median: 1, IQR 0-5, confidence interval of median [95% CI]: 0-3, P = 0.048), but no significant difference was found at 30 min (median: 1, IQR: 0-4 vs median: 6, IQR: 0-7, 95% CI: 0-5, P = 0.061), or 60 min (median: 0, IQR: 0-2 vs median: 1, IQR: 0-3, 95% CI: -1 to 1, P = 0.310). No significant difference was found in anesthesia time between the ultrasound-guided rectus sheath block and local anesthetic infiltration groups. No procedure-related complications were observed in either group

  8. An ultrasound needle insertion guide in a porcine phantom model.

    PubMed

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  9. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion.

    PubMed

    Venderink, Wulphert; Govers, Tim M; de Rooij, Maarten; Fütterer, Jurgen J; Sedelaar, J P Michiel

    2017-05-01

    Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. A decision tree and Markov model were developed to compare cost-effectiveness. Literature review and expert opinion were used as input. A strategy was deemed cost-effective if the costs of gaining one quality-adjusted life year (incremental cost-effectiveness ratio) did not exceed the willingness-to-pay threshold of €80,000 (≈$85,000 in January 2017). A base case analysis was performed to compare systematic transrectal ultrasound- and image fusion-guided biopsies. Because of a lack of appropriate literature regarding the accuracy of direct in-bore MRI-guided biopsy, a threshold analysis was performed. The incremental cost-effectiveness ratio for fusion-guided biopsy compared with systematic transrectal ultrasound-guided biopsy was €1386 ($1470) per quality-adjusted life year gained, which was below the willingness-to-pay threshold and thus assumed cost-effective. If MRI findings are normal in a patient with clinically significant prostate cancer, the sensitivity of direct in-bore MRI-guided biopsy has to be at least 88.8%. If that is the case, the incremental cost-effectiveness ratio is €80,000 per quality-adjusted life year gained and thus cost-effective. Fusion-guided biopsy seems to be cost-effective compared with systematic transrectal ultrasound-guided biopsy. Future research is needed to determine whether direct in-bore MRI-guided biopsy is the best pathway; in this study a threshold was calculated at which it would be cost-effective.

  10. Effectiveness of ultrasound-guided injections combined with shoulder exercises in the treatment of subacromial adhesive bursitis.

    PubMed

    Gasparre, Giuseppe; Fusaro, Isabella; Galletti, Stefano; Volini, Silvia; Benedetti, Maria Grazia

    2012-05-01

    The aim of this study was to evaluate whether the association of exercises for the shoulder with ultrasound-guided injection into the bursa significantly improves the treatment outcome in adhesive bursitis. Two groups of 35 patients, one treated with ultrasound-guided injection (UGI) and the other one with ultrasound-guided injection and home exercise program (UGI-exercise) for 1 month, were assessed for pain and shoulder function before treatment, 1 and 3 months post-treatment. Fourteen patients in UGI group and 23 patients in the UGI-exercises group were completely free of pain after 1 month (p = 0.031). At 3 months' follow-up, patients in the UGI-exercise group showed a significant improvement with respect to the other group (p = 0.005). No differences were found in function assessment. The UGI combined with shoulder exercises in the treatment of subacromial adhesive bursitis is effective to ensure a more frequent complete pain relief in the medium term.

  11. Evaluation of a simplified augmented reality device for ultrasound-guided vascular access in a vascular phantom.

    PubMed

    Jeon, Yunseok; Choi, Seungpyo; Kim, Heechan

    2014-09-01

    To investigate whether a novel ultrasound device may be used with a simplified augmented reality technique, and to compare this device with conventional techniques during vascular access using a vascular phantom. Prospective, randomized study. Anesthesiology and Pain Medicine departments of a university-affiliated hospital. 20 physicians with no experience with ultrasound-guided techniques. All participants performed the vascular access technique on the vascular phantom model using both a conventional device and the new ultrasound device. Time and the number of redirections of the needle until aspiration of dye into a vessel of the vascular phantom were measured. The median/interquartile range of time was 39.5/41.7 seconds versus 18.6/10.0 seconds (P < 0.001) and number of redirections was 3/3.5 versus 1/0 (P < 0.001) for the conventional and novel ultrasound devices, respectively. During vascular access in a vascular phantom model, the novel device decreased the time and the number of redirections significantly. The device successfully improved the efficiency of the ultrasound-guided vascular access technique. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Central venous pressure and shock index predict lack of hemodynamic response to volume expansion in septic shock: a prospective, observational study.

    PubMed

    Lanspa, Michael J; Brown, Samuel M; Hirshberg, Eliotte L; Jones, Jason P; Grissom, Colin K

    2012-12-01

    Volume expansion is a common therapeutic intervention in septic shock, although patient response to the intervention is difficult to predict. Central venous pressure (CVP) and shock index have been used independently to guide volume expansion, although their use is questionable. We hypothesize that a combination of these measurements will be useful. In a prospective, observational study, patients with early septic shock received 10-mL/kg volume expansion at their treating physician's discretion after brief initial resuscitation in the emergency department. Central venous pressure and shock index were measured before volume expansion interventions. Cardiac index was measured immediately before and after the volume expansion using transthoracic echocardiography. Hemodynamic response was defined as an increase in a cardiac index of 15% or greater. Thirty-four volume expansions were observed in 25 patients. A CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less individually had a good negative predictive value (83% and 88%, respectively). Of 34 volume expansions, the combination of both a high CVP and a low shock index was extremely unlikely to elicit hemodynamic response (negative predictive value, 93%; P = .02). Volume expansion in patients with early septic shock with a CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less is unlikely to lead to an increase in cardiac index. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    NASA Astrophysics Data System (ADS)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  14. [Venous access in oncology].

    PubMed

    Lesimple, T; Béguec, J F; Levêque, J M

    1998-10-31

    Many treatments administered to cancer patients require venous access either via a peripheral vein or a larger central vein at the risk of local or systemic infection, thrombus formation or venous occlusion and dysfunction. Insertion of a central catheter is an invasive procedure which must be conducted under conditions of rigorous asepsia. Strict rules based on well-defined protocols must be applied throughout its use. Local or systemic infectious complications account for 18 to 25% of all nosocomial infections and are often related to colonisation of the puncture site by a Gram positive germ. In case of infection, ablation of the central catheter is not mandatory for diagnosis or antibiotic treatment. Reported at varying frequencies in the literature from 4 to 42%, thrombus formation is unpredictable and often difficult to diagnose. Anticoagulants or fibrolytic agents are indicated but it may also be necessary to withdraw the catheter. Displacement, rupture, obstruction and extravasation are frequent complications. Back flow must be checked in all venous accesses and free flow carefully verified. The access must remain patent throughout the period of use, guaranteed by a standard heparinization and rinsing protocol. This complications must not mask the important progress achieved with the use of central venous access for specific and symptomatic treatment in cancer patients.

  15. Pre-procedure ultrasound-guided paramedian spinal anaesthesia at L5–S1: Is this better than landmark-guided midline approach? A randomised controlled trial

    PubMed Central

    Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2018-01-01

    Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151

  16. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2017-06-01

    standard transrectal ultrasound (TRUS) probe, a TUUS probe, and MRI. (a) (b) Figure 2: 3D printed prostate phantom mold (a), and pelvis phantom mold...with prostate agar phantom in place (b). The TUUS phantoms were prepared using a standard recipe [ii] for the prostate and the 3D printed mold...AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D -Transurethral Ultrasound and MRI Fusion PRINCIPAL

  17. Review of MRI positioning devices for guiding focused ultrasound systems.

    PubMed

    Yiallouras, C; Damianou, C

    2015-06-01

    This article contains a review of positioning devices that are currently used in the area of magnetic resonance imaging (MRI) guided focused ultrasound surgery (MRgFUS). The paper includes an extensive review of literature published since the first prototype system was invented in 1991. The technology has grown into a fast developing area with application to any organ accessible to ultrasound. The initial design operated using hydraulic principles, while the latest technology incorporates piezoelectric motors. Although, in the beginning there were fears regarding MRI safety, during recent years, the deployment of MR-safe positioning devices in FUS has become routine. Many of these positioning devices are now undergoing testing in clinical trials. Existing MRgFUS systems have been utilized mostly in oncology (fibroids, brain, liver, kidney, bone, pancreas, eye, thyroid, and prostate). It is anticipated that, in the near future, there will be a positioning device for every organ that is accessible by focused ultrasound. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    PubMed

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  19. Differentiation of deep venous thrombosis from femoral vein mixing artifact on routine abdominopelvic CT.

    PubMed

    Doshi, Ankur M; Hoffman, David; Kierans, Andrea S; Ream, Justin M; Rosenkrantz, Andrew B

    2015-10-01

    The objective of this study is to assess the performance of qualitative and quantitative imaging features for the differentiation of deep venous thrombosis (DVT) from mixing artifact on routine portal venous phase abdominopelvic CT. This retrospective study included 40 adult patients with a femoral vein filling defect on portal venous phase CT and a Duplex ultrasound (n = 36) or catheter venogram (n = 4) to confirm presence or absence of DVT. Two radiologists (R1, R2) assessed the femoral veins for various qualitative and quantitative features. 60% of patients were confirmed to have DVT and 40% had mixing artifact. Features with significantly greater frequency in DVT than mixing artifact (all p ≤ 0.006) were central location (R1 90% vs. 28%; R2 96% vs. 31%), sharp margin (R1 83% vs. 28%; R2 96% vs. 31%), venous expansion (R1 48% vs. 6%, R2 56% vs. 6%), and venous wall enhancement (R1 62% vs. 0%; R2 48% vs. 0%). DVT exhibited significantly lower mean attenuation than mixing artifact (R1 42.1 ± 20.2 vs. 57.1 ± 23.6 HU; R2 43.6 ± 19.4 vs. 58.8 ± 23.4 HU, p ≤ 0.031) and a significantly larger difference in vein diameter compared to the contralateral vein (R1 0.4 ± 0.4 vs. 0.1 ± 0.2 cm; R2 0.3 ± 0.4 vs. 0.0 ± 0.1 cm, p ≤ 0.026). At multivariable analysis, central location and sharp margin were significant independent predictors of DVT for both readers (p ≤ 0.013). Awareness of these qualitative and quantitative imaging features may improve radiologists' confidence for differentiating femoral vein DVT and mixing artifact on routine portal venous phase CT. However, given overlap with mixing artifact, larger studies remain warranted.

  20. Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.

    PubMed

    Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M

    2015-05-01

    Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.

  1. Ultrasound-Guided Rectus Sheath Block in Gynaecological Surgery with Pfannenstiel Incision

    PubMed Central

    Cüneyitoğlu, Şule; Türktan, Mediha; Biricik, Ebru; Özcengiz, Dilek

    2015-01-01

    Objective This study aimed to evaluate the effects of ultrasound-guided rectus sheath block in gynaecological surgery with Pfannenstiel incision. Methods After the approval of the ethics committee and the patients’ consent, 75 ASA I–II patients who were aged between 20 and 70 years and scheduled for a gynaecological surgery with Pfannenstiel incision were included in this study. After induction of general anaesthesia, patients were randomly divided into three groups. In Group UR patients (n=25), ultrasound-guided rectus sheath block with 0.25% levobupivacaine (0.2 mL kg−1) was performed. In Group SR patients (n=25), surgical rectus sheath block with 0.25% levobupivacaine (0.2 mL kg−1) was applied. In Group T (n=25) patients, tramadol (2 mg kg−1) was intravenously administered 30 min before the end of surgery. Patient-controlled analgesia device was established for postoperative pain relief in all groups. Haemodynamic data and inspired sevoflurane concentration were recorded during the operation. Pain scores, total tramadol consumption, supplemental analgesic requirement and side effects were postoperatively evaluated. Results Demographic characteristics, duration of surgery and haemodynamic parameters were similar between the groups. Inspired sevoflurane concentration (%) and VAS scores were significantly lower in Group UR than those in Groups SR and T. Total tramadol consumption was significantly lower in Groups UR and SR than that in Group T. There was no significant difference in the incidence of side effects. Conclusion This study demonstrates that ultrasound-guided rectus sheath block helps to provide the effective analgesia without any side effects compared with surgical rectus sheath block and intravenous tramadol for gynaecological surgery with Pfannenstiel incision. PMID:27366521

  2. Ultrasound-Guided Rectus Sheath Block in Gynaecological Surgery with Pfannenstiel Incision.

    PubMed

    Cüneyitoğlu, Şule; Türktan, Mediha; Biricik, Ebru; Özcengiz, Dilek

    2015-10-01

    This study aimed to evaluate the effects of ultrasound-guided rectus sheath block in gynaecological surgery with Pfannenstiel incision. After the approval of the ethics committee and the patients' consent, 75 ASA I-II patients who were aged between 20 and 70 years and scheduled for a gynaecological surgery with Pfannenstiel incision were included in this study. After induction of general anaesthesia, patients were randomly divided into three groups. In Group UR patients (n=25), ultrasound-guided rectus sheath block with 0.25% levobupivacaine (0.2 mL kg(-1)) was performed. In Group SR patients (n=25), surgical rectus sheath block with 0.25% levobupivacaine (0.2 mL kg(-1)) was applied. In Group T (n=25) patients, tramadol (2 mg kg(-1)) was intravenously administered 30 min before the end of surgery. Patient-controlled analgesia device was established for postoperative pain relief in all groups. Haemodynamic data and inspired sevoflurane concentration were recorded during the operation. Pain scores, total tramadol consumption, supplemental analgesic requirement and side effects were postoperatively evaluated. Demographic characteristics, duration of surgery and haemodynamic parameters were similar between the groups. Inspired sevoflurane concentration (%) and VAS scores were significantly lower in Group UR than those in Groups SR and T. Total tramadol consumption was significantly lower in Groups UR and SR than that in Group T. There was no significant difference in the incidence of side effects. This study demonstrates that ultrasound-guided rectus sheath block helps to provide the effective analgesia without any side effects compared with surgical rectus sheath block and intravenous tramadol for gynaecological surgery with Pfannenstiel incision.

  3. Risk factors associated with difficult venous access in adult ED patients.

    PubMed

    Fields, J Matthew; Piela, Nicole E; Au, Arthur K; Ku, Bon S

    2014-10-01

    The objective was to determine risk factors associated with difficult venous access (DVA) in the emergency department (ED). This was a prospective, observational study conducted in the ED of an urban tertiary care hospital. Adult patients undergoing intravenous (IV) placement were consecutively enrolled during periods of block enrollment. The primary outcome was DVA, defined as 3 or more IV attempts or use of a method of rescue vascular access to establish IV access. Univariate and multivariate analyses for factors predicting DVA were performed using logistic regression. A total of 743 patients were enrolled, of which 88 (11.8%) met the criteria for DVA. In the adjusted analysis, only 3 medical conditions were significantly associated with DVA: diabetes (odds ratio [OR] 1.72, 95% confidence interval [CI] 1.1-2.8), sickle cell disease (OR 3.8, 95% CI 1.5-9.5), and history of IV drug abuse (OR 2.5, 95% CI 1.1-5.7). Notably, age, body mass index, and dialysis were not. Of patients who reported a history of requiring multiple IV attempts in the past for IV access, 14% met criteria for DVA on this visit (OR 7.7 95% CI 3-18). Of the patients who reported a history of IV insertion into the external jugular, ultrasound-guided IV placement, or a central venous catheter for IV access, 26% had DVA on this visit (OR 16.7, 95% CI 6.8-41). Nearly 1 of every 9 to 10 adults in an urban ED had DVA. Diabetes, IV drug abuse, and sickle cell disease were found to be significantly associated with DVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    PubMed

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  5. MR-guided focused ultrasound: a potentially disruptive technology.

    PubMed

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  6. [Quality standards for ultrasound assessment of the superficial venous system of the lower limbs. Report of the French Society for Vascular Medicine].

    PubMed

    Auvert, J-F; Chleir, F; Coppé, G; Hamel-Desnos, C; Moraglia, L; Pichot, O

    2014-02-01

    The quality standards of the French Society for Vascular Medicine for the ultrasound assessment of the superficial venous system of the lower limbs are based on the two following requirements: technical know-how (mastering the use of ultrasound devices and the method of examination); medical know-how (ability to adapt the methods and scope of the examination to its clinical indications and purpose and to rationally analyze and interpret its results). To describe an optimal method of examination in relation to the clinical question and hypothesis; to achieve consistent practice, methods, glossary terminologies and reporting; to provide good practice reference points and to promote a high quality process. The three levels of examination. Their clinical indications and goals. The reference standard examination (level 2) and its variants according to clinical needs. The minimal content of the examination report, the letter to the referring physician (synthesis, conclusion and management suggestions) and iconography. Commented glossary (anatomy, hemodynamics, semiology). Technical basis. Ultrasound devices settings. We discuss of use of Duplex ultrasound for the assessment of the superficial veins of the lower limbs in vascular medicine practice. Copyright © 2014. Published by Elsevier Masson SAS.

  7. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    PubMed Central

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  8. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a

  9. [Prognostic analysis of plantar fasciitis treated by pneumatic ballistic extracorporeal shock wave versus ultrasound guided intervention].

    PubMed

    Huo, Xiu-Lin; Wang, Ke-Tao; Zhang, Xiao-Ying; Yang, Yi-Tian; Cao, Fu-Yang; Yang, Jing; Yuan, Wei-Xiu; Mi, Wei-Dong

    2018-02-20

    To compare the medium- and long-term effect of pneumatic ballistic extracorporeal shock wave versus ultrasound-guided hormone injection in the treatment of plantar fasciitis. The clinical data were collected from patients with plantar fasciitis admitted to PLA General Hospital pain department from September, 2015 to February, 2017. The patients were randomly divided into ultrasound-guided drug injection group and shock wave group. The therapeutic parameters including the numerical rating scale (NRS) scores in the first step pain in the morning, American Orthopedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale, and thickness of the plantar fascia were monitored before and at 1 week, 1 month, 3 months, and 6 months after the treatment. The recurrence rate, effectiveness, and patient satisfaction were compared between the two groups at 6 months after the treatment. Thirty-nine patients were enrolled in shock wave group and 38 patients in ultrasound group. The NRS scores in the first step pain in the morning were lowered after treatment in both groups (P<0.05), and the scores were significantly lower in ultrasound group than in shock wave group at 1 week and 1 month (P<0.01), but significantly higher in ultrasound group than in shock wave group at 3 and 6 months after treatment (P<0.05). The AOFAS functional scores were increased in both groups (P<0.05) at 6 months after treatment, was significantly lower in ultrasound group than in shock wave group than group B (90.44∓13.27 vs 75.76∓21.40; P<0.05). The effective rates in shock wave group and ultrasound group were 92.31% and 76.32%, respectively (P<0.05). Recurrence was found in 1 patient (2.56%) in shock wave group and in 8 (21.05%) in ultrasound group (P<0.05). The patient satisfaction scores were significantly higher in shock wave group than in ultrasound group (8.13∓2.67 vs 6.63∓3.75, P=0.048). Pneumatic ballistic extracorporeal shock achieves better medium- and long-term outcomes than ultrasound-guided

  10. Ultrasound-guided peripheral nerve interventions for common pain disorders

    PubMed Central

    Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh

    2018-01-01

    There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534

  11. Central venous catheter-related bloodstream infections in the intensive care unit

    PubMed Central

    Patil, Harsha V.; Patil, Virendra C.; Ramteerthkar, M. N.; Kulkarni, R. D.

    2011-01-01

    Context: Central venous catheter-related bloodstream infection (CRBSI) is associated with high rates of morbidity and mortality in critically ill patients. Aims: This study was conducted to determine the incidence of central venous catheter-related infections (CRIs) and to identify the factors influencing it. So far, there are very few studies that have been conducted on CRBSI in the intensive care unit in India. Settings and Design: This was a prospective, observational study carried out in the medical intensive care unit (MICU) over a period of 1 year from January to December 2004. Materials and Methods: A total of 54 patients with indwelling central venous catheters of age group between 20 and 75 years were included. The catheters were cultured using the standard semiquantitative culture (SQC) method. Statistical analysis used SPSS-10 version statistical software. Results: A total of 54 CVC catheters with 319 catheter days were included in this study. Of 54 patients with CVCs studied for bacteriology, 39 (72.22%) catheters showed negative SQCs and also negative blood cultures. A total of 15 (27.77%) catheters were positive on SQC, of which 10 (18.52%) were with catheter-associated infection and four (7.41%) were with catheter-associated bacteremia; the remaining one was a probable catheter-associated bacteremia. CRIs were high among catheters that were kept in situ for more than 3 days and emergency procedures where two or more attempts were required for catheterization (P < 0.05). In multivariate analysis of covariance duration of catheter in situ for >3 days, inexperienced venupucturist, more number of attempts and emergency CVC were associated with more incidence of CVCBSIs, with P <0.02. The duration of catheter in situ was negatively correlated (-0.53) and number of attempts required to put CVC was positively correlated (+0.39) with incidence of CVCBSIs. Sixty-five percent of the isolates belonged to the CONS group (13/20). Staphylococcus epidermidis showed

  12. A Rare Vascular Anomaly during Central Venous Catheterization: A Persistent Left-Sided Superior Vena Cava.

    PubMed

    Aydın, Kutlay; Tokur, Murat Emre; Ergan, Begüm

    2018-01-01

    A persistent left-sided superior vena cava (PLSVC) is the most frequent abnormality of the venous system; however, it is not a very well-known variation among physicians. Herein we report the case of a patient with a PLSVC who was diagnosed after central venous catheterization (CVC). An 80-year-old man was admitted to the emergency room with cardiopulmonary arrest. After the return of spontaneous circulation, CVC was blindly performed from the left jugular vein without any complications. However, routine chest X-ray after catheterization revealed that the catheter was moving down directly to the left heart. Thoracic computed tomography showed the right brachiocephalic vein draining into the left brachiocephalic vein and forming the left superior vena cava in front of the aortic arch. The left superior vena cava merged into the right atrium after crossing the left pulmonary artery. CVC is widely used in clinical practice, and therefore clinicians should be aware of possible variations in central veins, particularly during blind catheterization.

  13. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    PubMed

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  14. Laparoscopic-guided abdominal wall nerve blocks in the pediatric population: a novel technique with comparison to ultrasound-guided blocks and local wound infiltration alone.

    PubMed

    Landmann, Alessandra; Visoiu, Mihaela; Malek, Marcus M

    2018-03-01

    Abdominal wall nerve blocks have been gaining popularity for the treatment of perioperative pain in children. Our aim was to compare a technique of surgeon-performed, laparoscopic abdominal wall nerve blocks to anesthesia-placed, ultrasound-guided abdominal wall nerve blocks and the current standard of local wound infiltration. After institutional review board approval was obtained, a retrospective chart review was performed of pediatric patients treated at a single institution during a 2-year period. Statistics were calculated using analysis of variance with post-hoc Bonferonni t tests for pair-wise comparisons. Included in this study were 380 patients who received ultrasound-guided abdominal wall nerve blocks (n = 125), laparoscopic-guided abdominal wall nerve blocks (n = 88), and local wound infiltration (n = 117). Groups were well matched for age, sex, and weight. There was no significant difference in pain scores within the first 8 hours or narcotic usage between groups. Local wound infiltration demonstrated the shortest overall time required to perform (P < .0001). Patients who received a surgeon-performed abdominal wall nerve block demonstrated a shorter duration of hospital stay when compared to the other groups (P = .02). Our study has demonstrated that laparoscopic-guided abdominal wall nerve blocks show similar efficacy to ultrasound-guided nerve blocks performed by pain management physicians without increasing time in the operating room. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Current use of ultrasound for central vascular access in children and infants in the Nordic countries--a cross-sectional study.

    PubMed

    Olsen, Thomas C Risom; Rimstad, Ivan Jonassen; Tarpgaard, Mona; Holmberg, Svante; Hallas, Peter

    2015-01-01

    The use of ultrasound (US) guidance for central vascular access in children has been advocated as a safer approach compared to traditional landmark techniques. We therefore collected data on the current use of US for central vascular access in children and infants in the Nordic countries. A cross-sectional survey using an online questionnaire was distributed to one anaesthesiologist at every hospital in the Nordic countries; a total of 177 anaesthesiologists were contacted from July till August 2012. The use of US for placing central venous catheters (CVCs) seems widespread across the Nordic countries. Close to 80% of respondents were using it "almost always" or "frequently" across all paediatric age groups for internal jugular vein cannulation. US was least frequently used when catheterizing the subclavian vein. The two most common reasons given when not using US were lack of training followed by lack of equipment. We found no difference in the use of US between high-volume centres and low-volume centres. (High-volume centres placed paediatric CVCs at least weekly.). US was commonly used for cannulation of the internal jugular vein but infrequently for the subclavian vein. A lack of training seems to be a barrier for further increasing the use of US. Establishing standardized training programmes based on current evidence should alleviate this.

  16. Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

    PubMed Central

    Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung

    2017-01-01

    Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656

  17. Ultrasound Imaging and Guided Injection for the Lateral and Posterior Hip.

    PubMed

    Chang, Ke-Vin; Wu, Wei-Ting; Lew, Henry L; Özçakar, Levent

    2018-04-01

    Ultrasound has emerged as one of the most utilized tools to diagnose musculoskeletal disorders and to assist in interventions. Traditionally, sonographic examination of the hip joint has been challenging because most of the major structures are deeply situated, thus requiring the use of curvilinear transducer for better penetrance. The posterior lateral hip is a frequent area for musculoskeletal pain and nerve entrapments. Common disorders include greater trochanteric pain syndrome, gluteus medius tendinopathy, piriformis syndrome, pudendal neuralgia, and proximal hamstring tendinopathy. The present review article aims to delineate sonoanatomy of the posterior lateral hip and to exemplify several common ultrasound guided procedures at the greater trochanteric, gluteal, and ischial tuberosity regions.

  18. Central venous catheterization training: current perspectives on the role of simulation.

    PubMed

    Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher

    2018-01-01

    Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions.

  19. Targeted Ultrasound-Guided Perineural Hydrodissection of the Sciatic Nerve for the Treatment of Piriformis Syndrome.

    PubMed

    Burke, Christopher J; Walter, William R; Adler, Ronald S

    2018-05-01

    Piriformis syndrome is a common cause of lumbar, gluteal, and thigh pain, frequently associated with sciatic nerve symptoms. Potential etiologies include muscle injury or chronic muscle stretching associated with gait disturbances. There is a common pathological end pathway involving hypertrophy, spasm, contracture, inflammation, and scarring of the piriformis muscle, leading to impingement of the sciatic nerve. Ultrasound-guided piriformis injections are frequently used in the treatment of these pain syndromes, with most of the published literature describing injection of the muscle. We describe a safe, effective ultrasound-guided injection technique for the treatment of piriformis syndrome using targeted sciatic perineural hydrodissection followed by therapeutic corticosteroid injection.

  20. Percutaneous Image-Guided Aspiration and Sclerosis of Adventitial Cystic Disease of the Femoral Vein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Jason M.; Kiankhooy, Armin; Bertges, Daniel J.

    2009-07-15

    Adventitial cystic disease (ACD), also known as cystic mucoid or myxomatous degeneration, is a rare vascular disease mainly seen in arteries. Seventeen cases have been reported in the world literature. We report the first known case of ACD successfully treated with percutaneous image-guided ethanol sclerosis. Computed tomography showed a cystic mass adherent to the wall of the common femoral vein. An ultrasound examination revealed a deep venous thrombosis of the leg, secondary to extrinsic compression of the common femoral vein. Three years prior to our procedure, the cyst was aspirated, which partially relieved the patient's symptoms. Over the following 3more » years the patient's symptoms worsened and a 10-cm discrepancy in thigh size developed, in addition to the deep venous thrombosis associated with lower-extremity edema. Using ultrasound guidance and fluoroscopic control, the cyst was drained and then sclerosed with absolute ethanol. The patient's symptoms and leg swelling resolved completely within several weeks. Follow-up physical examination and duplex ultrasound 6 months following sclerosis demonstrated resolution of the symptoms and elimination of the extrinsic compression effect of the ACD on the common femoral vein.« less

  1. Endobronchial ultrasound-guided transbronchial needle injection for local control of recurrent non-small cell lung cancer.

    PubMed

    Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.

  2. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    PubMed

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  3. Emergency physician perspectives on central venous catheterization in the emergency department: a survey-based study.

    PubMed

    Ballard, Dustin W; Reed, Mary E; Rauchwerger, Adina S; Chettipally, Uli K; Offerman, Steven R; Mark, Dustin G; Vinson, David R

    2014-06-01

    The objective was to assess clinician experience, training, and attitudes toward central venous catheterization (CVC) in adult emergency department (ED) patients in a health system promoting increased utilization of CVC for severely septic ED patients. The authors surveyed all emergency physicians (EPs) within a 21-hospital integrated health care delivery system that had recently instituted a modified Rivers protocol for providing early goal-directed therapy (EGDT) to patients with severe sepsis or septic shock, including CVC if indicated. This initiative was accompanied by a structured, but optional, systemwide hands-on training for EPs in real-time ultrasound-guided CVC (US CVC). EPs' responses to questions regarding self-reported experience with CVC in the ED are reported. Data included frequency of CVC (by type) and US CVC training opportunities: both during and after residency and informal ("on-the-job training involving actual ED patients under the oversight of someone more experienced than yourself") and formal ("off-the-job training not involving actual ED patients"). The survey also asked respondents to report their comfort levels with different types of CVC as well as their agreement with possible barriers (philosophical, time-related, equipment-related, and complication-related) to CVC in the ED. Multivariable ordinal logistic regression was used to identify provider characteristics and responses associated with higher yearly CVC volumes. The survey response rate among eligible participants was 365 of 465 (78%). Overall, 154 of 365 (42%) respondents reported performing 11 or more CVCs a year, while 46 of 365 (13%) reported doing two or fewer. Concerning CVC techniques, 271 of 358 (76%) of respondents reported being comfortable with the internal jugular approach with US guidance, compared to 200 of 345 (58%) with the subclavian approach without US. Training rates were reported as 1) in residency, formal 167 of 358 (47%) and informal 189 of 364 (52%); and

  4. An analysis of leukapheresis and central venous catheter use in the randomized, placebo controlled, phase 3 IMPACT trial of Sipuleucel-T for metastatic castrate resistant prostate cancer.

    PubMed

    Flanigan, Robert C; Polcari, Anthony J; Shore, Neil D; Price, Thomas H; Sims, Robert B; Maher, Johnathan C; Whitmore, James B; Corman, John M

    2013-02-01

    Sipuleucel-T is an autologous cellular immunotherapy. We review the safety of the leukapheresis procedure required for sipuleucel-T preparation and complications related to venous catheter use in the randomized, placebo controlled phase 3 IMPACT (IMmunotherapy for ProstAte Cancer Trial) study (NCT 00065442). A total of 512 patients with asymptomatic or minimally symptomatic metastatic castrate resistant prostate cancer were enrolled in the study. All patients were scheduled to undergo 3 standard 1.5 to 2.0 blood volume leukapheresis procedures at 2-week intervals. Leukapheresis related adverse events and those related to venous catheter use were reviewed. Immune cell counts were examined throughout the treatment course. Of 512 enrolled patients 506 underwent 1 or more leukapheresis procedures and were included in this analysis. Adverse events were comparable between the sipuleucel-T and control arms. Leukapheresis related adverse events were primarily associated with transient hypocalcemia (39.3%). Most leukapheresis related adverse events (97%) were of mild/moderate intensity. Median white blood cell count and absolute monocyte and lymphocyte counts were stable and within normal ranges throughout the treatment course. Of all patients 23.3% had a central venous catheter placed primarily for leukapheresis. Patients with vs without a central venous catheter had a higher risk of infection potentially related to catheter use (11.9% vs 1.3%, p <0.0001) and a trend toward a higher incidence of venous vascular events potentially related to catheter use, excluding the central nervous system (5.9% vs 2.1%, p = 0.06). Adverse events related to leukapheresis are manageable and quickly reversible. The majority of patients can undergo leukapheresis without a central venous catheter. Central venous catheters are associated with an increased risk of infections and venous vascular events. Peripheral intravenous access should be used when feasible. Copyright © 2013 American

  5. Accuracy of electromyography needle placement in cadavers: non-guided vs. ultrasound guided.

    PubMed

    Boon, Andrea J; Oney-Marlow, Theresa M; Murthy, Naveen S; Harper, Charles M; McNamara, Terrence R; Smith, Jay

    2011-07-01

    Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory. Copyright © 2011 Wiley Periodicals, Inc.

  6. A pitfall during endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes.

    PubMed

    Krenke, Rafal; Korczynski, Piotr; Gorska, Katarzyna; Chazan, Ryszarda

    2014-03-01

    The high diagnostic yield and favorable safety profile of endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes have been recently demonstrated. We report an unusual technical problem during endobronchial ultrasound-guided transbronchial forceps biopsy that could be a prerequisite for severe complications. A rupture of the steering band precluded closure of the forceps jaws opened in the subcarinal lymph node. A solution to the problem is presented, together with other procedure-related complications reported in the literature. The report emphasizes that a dysfunction of the forceps steering band can result in severe complications when it occurs during transbronchial sampling of mediastinal lesions. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Polyplex-microbubble hybrids for ultrasound-guided plasmid DNA delivery to solid tumors.

    PubMed

    Sirsi, Shashank R; Hernandez, Sonia L; Zielinski, Lukasz; Blomback, Henning; Koubaa, Adel; Synder, Milo; Homma, Shunichi; Kandel, Jessica J; Yamashiro, Darrell J; Borden, Mark A

    2012-01-30

    Microbubble ultrasound contrast agents are being developed as image-guided gene carriers for targeted delivery in vivo. In this study, novel polyplex-microbubbles were synthesized, characterized and evaluated for systemic circulation and tumor transfection. Branched polyethylenimine (PEI; 25 kDa) was modified with polyethylene glycol (PEG; 5 kDa), thiolated and covalently attached to maleimide groups on lipid-coated microbubbles. The PEI-microbubbles demonstrated increasingly positive surface charge and DNA loading capacity with increasing maleimide content. The in vivo ultrasound contrast persistence of PEI-microbubbles was measured in the healthy mouse kidney, and a two-compartment pharmacokinetic model accounting for free and adherent microbubbles was developed to describe the anomalous time-intensity curves. The model suggested that PEI loading dramatically reduced free circulation and increased nonspecific adhesion to the vasculature. However, DNA loading to form polyplex-microbubbles increased circulation in the bloodstream and decreased nonspecific adhesion. PEI-microbubbles coupled to a luciferase bioluminescence reporter plasmid DNA were shown to transfect tumors implanted in the mouse kidney. Site-specific delivery was achieved using ultrasound applied over the tumor area following bolus injection of the DNA/PEI-microbubbles. In vivo imaging showed over 10-fold higher bioluminescence from the tumor region compared to untreated tissue. Ex vivo analysis of excised tumors showed greater than 40-fold higher expression in tumor tissue than non-sonicated control (heart) tissue. These results suggest that the polyplex-microbubble platform offers improved control of DNA loading and packaging suitable for ultrasound-guided tissue transfection. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Holistic ultrasound in trauma: An update.

    PubMed

    Saranteas, Theodosios; Mavrogenis, Andreas F

    2016-10-01

    Holistic ultrasound is a total body examination using an ultrasound device aiming to achieve immediate patient care and decision making. In the setting of trauma, it is one of the most fundamental components of care of the injured patients. Ground-breaking imaging software allows physicians to examine various organs thoroughly, recognize imaging signs early, and potentially foresee the onset or the possible outcome of certain types of injuries. Holistic ultrasound can be performed on a routine basis at the bedside of the patients, at admission and during the perioperative period. Trauma care physicians should be aware of the diagnostic and guidance benefits of ultrasound and should receive appropriate training for the optimal management of their patients. In this paper, the findings of holistic ultrasound in trauma patients are presented, with emphasis on the lungs, heart, cerebral circulation, abdomen, and airway. Additionally, the benefits of ultrasound imaging in interventional anaesthesia techniques such as ultrasound-guided peripheral nerve blocks and central vein catheterization are described. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis.

    PubMed

    Keil-Ríos, Daniel; Terrazas-Solís, Hiram; González-Garay, Alejandro; Sánchez-Ávila, Juan Francisco; García-Juárez, Ignacio

    2016-04-01

    The pocket ultrasound device (PUD) is a new tool that may be of use in the early detection of ascites. Abdominal ultrasound-guided paracentesis has been reported to decrease the rate of complications due to the procedure, but must be performed in a healthcare setting; this new tool may be a useful on an ambulatory basis. The aim of this study was to determine the diagnostic usefulness of the PUD in the diagnosis of ascites and the safety of guided paracentesis. We conducted a retrospective study that included adult patients suspected of having ascites and in whom an evaluation was performed with the PUD to identify it. Concordance with abdominal ultrasound (AUS) was determined with the Kappa coefficient. Sensitivity (Se), specificity (Sp) and likelihood ratios (LR) were determined and compared with physical examination, AUS, computed tomography and procurement of fluid by paracentesis. Complications resulting from the guided paracentesis were analyzed. 89 participants were included and 40 underwent a paracentesis. The PUD for ascites detection had 95.8 % Se, 81.8 % Sp, 5.27 +LR and 0.05 -LR. It had a concordance with AUS of 0.781 (p < 0.001). Technical problems during the guided paracentesis were present in only two participants (5 %) and three patients (7.5 %) developed minor complications that required no further intervention. There were no severe complications or deaths. This study suggests that the PUD is a reliable tool for ascites detection as a complement to physical examination and appears to be a safe method to perform guided paracentesis.

  10. A serious game for learning ultrasound-guided needle placement skills.

    PubMed

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  11. Long-term follow-up of ultrasound-guided botulinum toxin-A injections for sialorrhea in neurological dysphagia.

    PubMed

    Barbero, Pierangelo; Busso, Marco; Tinivella, Marco; Artusi, Carlo Alberto; De Mercanti, Stefania; Cucci, Angele; Veltri, Andrea; Avagnina, Paolo; Calvo, Andrea; Chio', Adriano; Durelli, Luca; Clerico, Marinella

    2015-12-01

    Literature provides reports only of a limited follow-up single injection of botulinum toxin-A (BoNT-A) in patients with sialorrhea. The aim of our study is to evaluate the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for severe sialorrhea secondary to neurological dysphagia. We enrolled 38 severe adult sialorrhea patients referred consecutively to the neurology unit and performed bilateral parotid and submandibular gland BoNT-A injections under ultrasound guidance. The outcomes of the study were reduction of sialorrhea, duration of therapeutic effect, and subjective patient- and caregiver-reported satisfaction. A total of 113 BoNT-A administrations were given during the study period with a mean duration of follow-up of 20.2 ± 4.4 months. We observed a significant decrease from baseline in mean number of daily aspirations and a significant improvement in patient- and caregiver-reported outcomes following ultrasound-guided BoNT-A injections (p < 0.001 vs baseline for all comparisons) and the mean duration of the efficacy was 5.6 ± 1 months. No major treatment-related adverse events occurred and a low incidence of minor adverse events was reported. This study confirms the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for sialorrhea, regardless of the causative neurological disorder. These results should encourage the use of BoNT-A in the treatment of severe sialorrhea and highlight the role of ultrasound guidance to obtain optimal results in terms of safety and reproducible outcomes.

  12. Increased rate of venous thrombosis may be associated with inpatient dihydroergotamine treatment.

    PubMed

    Tso, Amy R; Patniyot, Irene R; Gelfand, Amy A; Goadsby, Peter J

    2017-07-18

    To review whether the incidence of catheter-associated venous thromboses was higher in patients receiving IV dihydroergotamine compared to lidocaine. We retrospectively reviewed all admissions at the University of California, San Francisco Headache Center from February 25, 2008, through October 31, 2014, for age, sex, diagnosis, aura, treatment dose, type of IV line used, days with line, superficial (SVT) or deep venous thrombosis (DVT), and pulmonary embolism (PE). A peripherally inserted central catheter (PICC) or midline catheter was placed in 315 of 589 (53%) admissions. Mean age was 38 years with a range of 6 to 79 years; 121 patients (21%) were ≤18 years old. Seventy-four percent (433 of 589) of patients were female. Of 263 dihydroergotamine admissions using a PICC or midline catheter, 19 (7.2%) had either an SVT or DVT or a PE; 2 patients were diagnosed with both DVT and PE. Of 52 lidocaine admissions using a PICC or midline catheter, none had a thrombotic event ( p = 0.05, Fisher exact test). Age, sex, aura, total dihydroergotamine dose, and number of days with line were not significant predictors of venous thrombosis. IV dihydroergotamine treatment may be associated with an increased risk of catheter-associated venous thrombosis. A low threshold for diagnostic ultrasound investigation is appropriate because anticoagulation therapy was frequently required. © 2017 American Academy of Neurology.

  13. Risk factors associated with PICC-related upper extremity venous thrombosis in cancer patients.

    PubMed

    Yi, Xiao-lei; Chen, Jie; Li, Jia; Feng, Liang; Wang, Yan; Zhu, Jia-An; Shen, E; Hu, Bing

    2014-03-01

    To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality

  14. Risk of deep venous thrombosis in elective neurosurgical procedures: a prospective, Doppler ultrasound-based study in children 12 years of age or younger.

    PubMed

    Scherer, Andrea G; White, Ian K; Shaikh, Kashif A; Smith, Jodi L; Ackerman, Laurie L; Fulkerson, Daniel H

    2017-07-01

    OBJECTIVE The risk of venous thromboembolism (VTE) from deep venous thrombosis (DVT) is significant in neurosurgical patients. VTE is considered a leading cause of preventable hospital deaths and preventing DVT is a closely monitored quality metric, often tied to accreditation, hospital ratings, and reimbursement. Adult protocols include prophylaxis with anticoagulant medications. Children's hospitals may adopt adult protocols, although the incidence of DVT and the risk or efficacy of treatment is not well defined. The incidence of DVT in children is likely less than in adults, although there is very little prospectively collected information. Most consider the risk of DVT to be extremely low in children 12 years of age or younger. However, this consideration is based on tradition and retrospective reviews of trauma databases. In this study, the authors prospectively evaluated pediatric patients undergoing a variety of elective neurosurgical procedures and performed Doppler ultrasound studies before and after surgery. METHODS A total of 100 patients were prospectively enrolled in this study. All of the patients were between the ages of 1 month and 12 years and were undergoing elective neurosurgical procedures. The 91 patients who completed the protocol received a bilateral lower-extremity Doppler ultrasound examination within 48 hours prior to surgery. Patients did not receive either medical or mechanical DVT prophylaxis during or after surgery. The ultrasound examination was repeated within 72 hours after surgery. An independent, board-certified radiologist evaluated all sonograms. We prospectively collected data, including potential risk factors, details of surgery, and details of the clinical course. All patients were followed clinically for at least 1 year. RESULTS There was no clinical or ultrasound evidence of DVT or VTE in any of the 91 patients. There was no clinical evidence of VTE in the 9 patients who did not complete the protocol. CONCLUSIONS In this

  15. Superior vena cava syndrome with central venous catheter for chemotherapy treated successfully with fibrinolysis.

    PubMed

    Guijarro Escribano, J F; Antón, R F; Colmenarejo Rubio, A; Sáenz Cascos, L; Sainz González, F; Alguacil Rodríguez, R

    2007-03-01

    Recently, there has been an increase in the number of cases of superior vena cava (SVC) syndrome associated with chronic indwelling central venous catheters. Fibrinolytic therapy and endovascular treatment are currently achieving good results. We present a case history of a patient with SVC with a catheter used for chemotherapy, which was successfully treated with catheter-directed (intraclot) infusion thrombolytic therapy with urokinase.

  16. Low central venous pressure versus acute normovolemic hemodilution versus conventional fluid management for reducing blood loss in radical retropubic prostatectomy: a randomized controlled trial.

    PubMed

    Habib, Ashraf S; Moul, Judd W; Polascik, Thomas J; Robertson, Cary N; Roche, Anthony M; White, William D; Hill, Stephen E; Nosnick, Israel; Gan, Tong J

    2014-05-01

    To compare acute normovolemic hemodilution versus low central venous pressure strategy versus conventional fluid management in reducing intraoperative estimated blood loss, hematocrit drop and need for blood transfusion in patients undergoing radical retropubic prostatectomy under general anesthesia. Patients undergoing radical retropubic prostatectomy under general anesthesia were randomized to conventional fluid management, acute normovolemic hemodilution or low central venous pressure (≤5 mmHg). Treatment effects on estimated blood loss and hematocrit change were tested in multivariable regression models accounting for surgeon, prostate size, and all two-way interactions. Ninety-two patients completed the study. Estimated blood loss (mean ± SD) was significantly lower with low central venous pressure (706 ± 362 ml) compared to acute normovolemic hemodilution (1103 ± 635 ml) and conventional (1051 ± 714 ml) groups (p = 0.0134). There was no difference between the groups in need for blood transfusion, or hematocrit drop from preoperative values. The multivariate model predicting estimated blood loss showed a significant effect of treatment (p = 0.0028) and prostate size (p = 0.0323), accounting for surgeon (p = 0.0013). In the model predicting hematocrit change, accounting for surgeon difference (p = 0.0037), the treatment effect depended on prostate size (p = 0.0007) with the slope of low central venous pressure differing from the other two groups. Hematocrit was predicted to drop more with increased prostate size in acute normovolemic hemodilution and conventional groups but not with low central venous pressure. Limitations include the inability to blind providers to group assignment, possible variability between providers in estimation of blood loss, and the relatively small sample size that was not powered to detect differences between the groups in need for blood transfusion. Maintaining low central venous

  17. Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound.

    PubMed

    Furtado, Rita Nely Vilar; Pereira, Daniele Freitas; da Luz, Karine Rodrigues; dos Santos, Marla Francisca; Konai, Monique Sayuri; Mitraud, Sonia de Aguiar Vilela; Rosenfeld, Andre; Fernandes, Artur da Rocha Correa; Natour, Jamil

    2013-01-01

    Compare the effectiveness of ultrasound and fluoroscopy to guide intra-articular injections (IAI) in selected cases. A prospective study in our outpatient clinics at the Rheumatology Division at Universidade Federal de São Paulo (UNIFESP), Brazil, was conducted to compare the short-term (4 weeks) effectiveness of ultrasound and fluoroscopy-guided IAI in patients with rheumatic diseases. Inclusion criteria were: adults with refractory synovitis undergoing IAI with glucocorticoid. All patients had IAI performed with triamcinolone hexacetonide (20mg/ml) with varying doses according to the joint injected. A total of 71 rheumatic patients were evaluated (52 women, 44 whites). Mean age was 51.9 ± 13 years and 47 of them (66.2%) were on regular DMARD use. Analysis of the whole sample (71 patients) and hip sub-analysis (23 patients) showed that significant improvement was observed for both groups in terms of pain (P < 0.001). Global analysis also demonstrated better outcomes for patients in the FCG in terms of joint flexion (P < 0.001) and percentage change in joint flexion as compared to the USG. Likert scale score analyses demonstrated better results for the patients in the USG as compared to the FCG at the end of the study (P < 0.05). No statistically significant difference between groups was observed for any other study variable. Imaging-guided IAI improves regional pain in patients with various types of synovitis in the short term. For the vast majority of variables, no significant difference in terms of effectiveness was observed between fluoroscopy and ultrasound guided IAI.

  18. Percutaneous Treatment of Central Venous Stenosis in Hemodialysis Patients: Long-Term Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Young Chul; Won, Jong Yun, E-mail: jywon@yumc.yonsei.ac.kr; Choi, Sun Young

    2009-03-15

    The purpose of this study was to evaluate the long-term outcomes of endovascular treatment of central venous stenosis in patients with arteriovenous fistulas (AVFs) for hemodialysis. Five hundred sixty-three patients with AVFs who were referred for a fistulogram were enrolled in this study. Among them, 44 patients showed stenosis (n = 35) or occlusions (n = 9) in the central vein. For the initial treatment, 26 patients underwent percutaneous transluminal angioplasty (PTA) and 15 patients underwent stent placements. Periods between AVF formation and first intervention ranged from 3 to 144 months. Each patient was followed for 14 to 60 months.more » Procedures were successful in 41 of 44 patients (93.2%). Primary patency rates for PTA at 12 and 36 months were 52.1% and 20.0%, and assisted primary patency rates were 77.8% and 33.3%, respectively. Primary patency rates for stent at 12 and 36 months were 46.7% and 6.7%, and assisted primary patency rates were 60.0% and 20.0%, respectively. Fifteen of 26 patients with PTAs underwent repeated interventions because of restenosis. Fourteen of 15 patients with a stent underwent repeated interventions because of restenosis and combined migration (n = 1) and shortening (n = 6) of the first stent. There was no significant difference in patency between PTAs and stent placement (p > 0.05). Average AVF patency duration was 61.8 months and average number of endovascular treatments was 2.12. In conclusion, endovascular treatments of central venous stenosis could lengthen the available period of AVFs. There was no significant difference in patency between PTAs and stent placement.« less

  19. ASSESSMENT OF VENOUS THROMBOSIS IN ANIMAL MODELS

    PubMed Central

    SP, Grover; CE, Evans; AS, Patel; B, Modarai; P, Saha; A, Smith

    2016-01-01

    Deep vein thrombosis and common complications, including pulmonary embolism and post thrombotic syndrome, represent a major source of morbidity and mortality worldwide. Experimental models of venous thrombosis have provided considerable insight into the cellular and molecular mechanisms that regulate thrombus formation and subsequent resolution. Here we critically appraise the ex vivo and in vivo techniques used to assess venous thrombosis in these models. Particular attention is paid to imaging modalities, including magnetic resonance imaging, micro computed tomography and high frequency ultrasound that facilitate longitudinal assessment of thrombus size and composition. PMID:26681755

  20. Comparison of Central Corneal Thickness Between Fourier-Domain OCT, Very High-Frequency Digital Ultrasound, and Scheimpflug Imaging Systems.

    PubMed

    Yap, Timothy E; Archer, Timothy J; Gobbe, Marine; Reinstein, Dan Z

    2016-02-01

    To compare corneal thickness measurements between three imaging systems. In this retrospective study of 81 virgin and 58 post-laser refractive surgery corneas, central and minimum corneal thickness were measured using optical coherence tomography (OCT), very high-frequency digital ultrasound (VHF digital ultrasound), and a Scheimpflug imaging system. Agreement between methods was analyzed using mean differences (bias) (OCT - VHF digital ultrasound, OCT - Scheimpflug, VHF digital ultrasound - Scheimpflug) and Bland-Altman analysis with 95% limits of agreement (LoA). Virgin cornea mean central corneal thickness was 508.3 ± 33.2 µm (range: 434 to 588 µm) for OCT, 512.7 ± 32.2 µm (range: 440 to 587 µm) for VHF digital ultrasound, and 530.2 ± 32.6 µm (range: 463 to 612 µm) for Scheimpflug imaging. OCT and VHF digital ultrasound showed the closest agreement with a bias of -4.37 µm, 95% LoA ±12.6 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -21.9 µm, 95% LoA ±20.7 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -17.5 µm, 95% LoA ±19.0 µm. In post-laser refractive surgery corneas, mean central corneal thickness was 417.9 ± 47.1 µm (range: 342 to 557 µm) for OCT, 426.3 ± 47.1 µm (range: 363 to 563 µm) for VHF digital ultrasound, and 437.0 ± 48.5 µm (range: 359 to 571 µm) for Scheimpflug imaging. Closest agreement was between OCT and VHF digital ultrasound with a bias of -8.45 µm, 95% LoA ±13.2 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -19.2 µm, 95% LoA ±19.2 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -10.7 µm, 95% LoA ±20.0 µm. No relationship was observed between difference in central corneal thickness measurements and mean central corneal thickness. Results were similar for minimum corneal thickness. Central and minimum corneal thickness was measured thinnest by OCT and thickest by Scheimpflug imaging in both groups. A clinically

  1. Value of artisanal simulators to train veterinary students in performing invasive ultrasound-guided procedures.

    PubMed

    Hage, Maria Cristina F N S; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-03-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are recommended for this practice. The present study aimed to create a model that can be made "at home" at low cost for ultrasound-guided pericardiocentesis training and to gather feedback about this model through questionnaires given to the participants. Eighteen professionals and thirty-six students were introduced to the simulator in pairs. After the simulation training session, participants filled out the questionnaire. Participants considered the model strong in the following areas: visualization of the pericardium, the heart, fluid in the pericardium, and fluid decrease during fictitious pericardiocentesis and its realism. They considered the model weak or moderate in the following areas: visualization of the surrounding tissues, difficulty of pericardial puncture, and visualization of the catheter. The professionals classified the realism of the experimental heart as moderate, whereas the undergraduate students classified it as strong. All participants believed that the experimental model could be useful in preparing for a future real situation. This model fulfills the need for a practical, realistic, and cost-effective model for ultrasound-guided pericardiocentesis training. Copyright © 2016 The American Physiological Society.

  2. Impact of Ultrasound on Short Peripheral Intravenous Catheter Placement on Vein Thrombosis Risk.

    PubMed

    Holder, Max R; Stutzman, Sonja E; Olson, DaiWai M

    Approximately 90% of hospitalized patients have a short peripheral intravenous catheter (SPC) placed. Methods of inserting the catheter have evolved over time and now include the use of ultrasound (US)-guided procedures for placement. Little is known about the impact that US-guided procedures have on the vein. This study compared the rate of venous thrombosis in patients with and without US-guided catheter placement. This prospective, single-blind, observational study assessed for venous thrombosis in 153 veins from 135 patients. Veins were evaluated by a research nurse blinded to the method of placement between 48 and 72 hours after the SPC was placed. The Fisher exact test showed a significant difference between vessel compressibility and catheter insertion method (P = .0012). The proportion of noncompressible veins was significantly greater when US was used in comparison with freehand SPC insertion. The Mantel-Haenszel chi-square value of 10.34 (P = .0013) showed that US insertion technique is associated with a higher likelihood of noncompressible veins. This pilot study provides compelling evidence that the use of US to assist with catheter placement is associated with a higher rate of noncompressible veins at day 2 or 3. Further studies are needed with a larger sample to determine the generalizability of the results from this pilot study.

  3. Central venous device-related thrombosis as imaged with MDCT in oncologic patients: prevalence and findings.

    PubMed

    Catalano, Orlando; de Lutio di Castelguidone, Elisabetta; Sandomenico, Claudia; Petrillo, Mario; Aprea, Pasquale; Granata, Vincenza; D'Errico, Adolfo Gallipoli

    2011-03-01

    Venous thrombosis is a common occurrence in cancer patients, developing spontaneously or in combination with indwelling central venous devices (CVD). To analyze the multidetector CT (MDCT) prevalence, appearance, and significance of catheter-related thoracic venous thrombosis in oncologic patients and to determine the percentage of thrombi identified in the original reports. Five hundred consecutive patients were considered. Inclusion criteria were: presence of a CVD; availability of a contrast-enhanced MDCT; and cancer history. Exclusion criteria were: direct tumor compression/infiltration of the veins; poor image quality; device tip not in the scanned volume; and missing clinical data. Seventeen (3.5%) out of the final 481 patients had a diagnosis of venous thrombosis. Factors showing the highest correlation with thrombosis included peripherally-inserted CVD, right brachiocephalic vein tip location, patient performance status 3, metastatic stage disease, ongoing chemotherapy, and longstanding CVD. The highest prevalence was in patients with lymphoma, lung carcinoma, melanoma, and gynecologic malignancies. Eleven out of 17 cases had not been identified in the original report. CVD-related thrombosis is not uncommon in cancer patients and can also be observed in outpatients with a good performance status and a non-metastatic disease. Thrombi can be very tiny. Radiologists should be aware of the possibility to identify (or overlook) small thrombi.

  4. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    PubMed

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  5. Analytical estimation of ultrasound properties, thermal diffusivity, and perfusion using magnetic resonance-guided focused ultrasound temperature data

    PubMed Central

    Dillon, C R; Borasi, G; Payne, A

    2016-01-01

    For thermal modeling to play a significant role in treatment planning, monitoring, and control of magnetic resonance-guided focused ultrasound (MRgFUS) thermal therapies, accurate knowledge of ultrasound and thermal properties is essential. This study develops a new analytical solution for the temperature change observed in MRgFUS which can be used with experimental MR temperature data to provide estimates of the ultrasound initial heating rate, Gaussian beam variance, tissue thermal diffusivity, and Pennes perfusion parameter. Simulations demonstrate that this technique provides accurate and robust property estimates that are independent of the beam size, thermal diffusivity, and perfusion levels in the presence of realistic MR noise. The technique is also demonstrated in vivo using MRgFUS heating data in rabbit back muscle. Errors in property estimates are kept less than 5% by applying a third order Taylor series approximation of the perfusion term and ensuring the ratio of the fitting time (the duration of experimental data utilized for optimization) to the perfusion time constant remains less than one. PMID:26741344

  6. Demonstration of antibiofilm and antifungal efficacy of chitosan against candidal biofilms, using an in vivo central venous catheter model.

    PubMed

    Martinez, Luis R; Mihu, Mircea Radu; Tar, Moses; Cordero, Radames J B; Han, George; Friedman, Adam J; Friedman, Joel M; Nosanchuk, Joshua D

    2010-05-01

    Candida species are a major cause of catheter infections. Using a central venous catheter Candida albicans biofilm model, we demonstrated that chitosan, a polymer isolated from crustacean exoskeletons, inhibits candidal biofilm formation in vivo. Furthermore, chitosan statistically significantly decreased both the metabolic activity of the biofilms and the cell viability of C. albicans and Candida parapsilosis biofilms in vitro. In addition, confocal and scanning electron microscopic examination demonstrated that chitosan penetrates candidal biofilms and damages fungal cells. Importantly, the concentrations of chitosan that were used to evaluate fungal biofilm susceptibility were not toxic to human endothelial cells. Chitosan should be considered for the prevention or treatment of fungal biofilms on central venous catheters and perhaps other medical devices.

  7. Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.

    PubMed

    Ozmen, Evrim; Algin, Oktay

    2016-07-12

    Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.

  8. Development of a 3D ultrasound-guided prostate biopsy system

    NASA Astrophysics Data System (ADS)

    Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron

    2007-03-01

    Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.

  9. Transhepatic Embolization of Congenital Intrahepatic Portosystemic Venous Shunts with Associated Aneurysms

    PubMed Central

    Paudel, Kalyan; Hoffer, Eric K.

    2015-01-01

    Intrahepatic shunts between the portal and systemic venous systems with associated aneurysms are extremely rare. A middle aged woman presented with hepatic encephalopathy and was found to have two intrahepatic portosystemic venous shunts with associated aneurysms. Diagnosis was made by duplex ultrasound and was confirmed with contrast enhanced MRI. Treatment was performed percutaneously with an Amplatzer vascular plug. PMID:26257785

  10. Comparison of three types of central venous catheters in patients with malignant tumor receiving chemotherapy

    PubMed Central

    Fang, Shirong; Yang, Jinhong; Song, Lei; Jiang, Yan; Liu, Yuxiu

    2017-01-01

    Background Central venous catheters (CVCs) have been an effective access for chemotherapy instead of peripherally intravenous catheters. There were limited studies on the choices and effects of different types of CVCs for chemotherapy. The aim of this study was to compare the complications, cost, and patients’ quality of life and satisfaction of three commonly used CVCs for chemotherapy, such as implanted venous port, peripherally inserted central catheters (PICCs), and external non-tunneled central venous catheters (NTCs). Methods A double-center prospective cohort study was carried out from March 2014 to December 2016. Catheterization situation, complications, catheter maintenance, cost, and patients’ quality of life and satisfaction were recorded, investigated, and analyzed. Forty-five ports, 60 PICCs and 40 NTCs were included. All the CVCs were followed up to catheter removal. Results There was no statistical difference in catheterization success rates between port and PICC. NTC had less success rate by one puncture compared with port. Ports had fewer complications compared with PICCs and NTCs. The complication rates of ports, PICCs and NTCs were 2.2%, 40%, and 27.5%, respectively. If the chemotherapy process was <12 months, NTCs cost least, and the cost of port was much higher than PICC and NTC. When the duration time was longer than 12 months, the cost of port had no difference with the cost of PICC. Quality of life and patients’ satisfaction of port group were significantly higher than the other two groups. Conclusion Although port catheterization costs more and needs professional medical staff and strict operational conditions, ports have fewer complications and higher quality of life and patients’ satisfaction than PICCs and NTCs. Therefore, not following consideration of the economic factor, we recommend port as a safe and an effective chemotherapy access for cancer patients, especially for whom needing long chemotherapy process. PMID:28744109

  11. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    PubMed

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the

  12. Central venous catheterization training: current perspectives on the role of simulation

    PubMed Central

    Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher

    2018-01-01

    Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions. PMID:29872360

  13. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  14. Models to teach lung sonopathology and ultrasound-guided thoracentesis.

    PubMed

    Wojtczak, Jacek A

    2014-12-01

    Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand - eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter's hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.

  15. Measurement of central venous pressure and determination of hormones in blood serum during weightlessness

    NASA Technical Reports Server (NTRS)

    Kirsch, K.

    1981-01-01

    A Spacelab experiment is described which proposes to obtain data on the degree of engorgement of the cephalad circulation during weightlessness by recording central venous pressure. Of practical importance is the question of how close the astronauts are to pulmonary edema and whether the pressure falls toward normal during the time of the mission. Another experiment to investigate deviations from normal fluid and mineral metabolism, possibly initiated by the central engorgement of the low pressure system, is discussed. Hormones responsible for the control of water and mineral balance (vasopressin, catecholamines, renin, aldosterone, corticosteroids, and prostaglandin E1) will be analyzed from blood samples.

  16. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  17. Management of Central Venous Access Device-Associated Skin Impairment: An Evidence-Based Algorithm.

    PubMed

    Broadhurst, Daphne; Moureau, Nancy; Ullman, Amanda J

    Patients relying on central venous access devices (CVADs) for treatment are frequently complex. Many have multiple comorbid conditions, including renal impairment, nutritional deficiencies, hematologic disorders, or cancer. These conditions can impair the skin surrounding the CVAD insertion site, resulting in an increased likelihood of skin damage when standard CVAD management practices are employed. Supported by the World Congress of Vascular Access (WoCoVA), developed an evidence- and consensus-based algorithm to improve CVAD-associated skin impairment (CASI) identification and diagnosis, guide clinical decision-making, and improve clinician confidence in managing CASI. A scoping review of relevant literature surrounding CASI management was undertaken March 2014, and results were distributed to an international advisory panel. A CASI algorithm was developed by an international advisory panel of clinicians with expertise in wounds, vascular access, pediatrics, geriatric care, home care, intensive care, infection control and acute care, using a 2-phase, modified Delphi technique. The algorithm focuses on identification and treatment of skin injury, exit site infection, noninfectious exudate, and skin irritation/contact dermatitis. It comprised 3 domains: assessment, skin protection, and patient comfort. External validation of the algorithm was achieved by prospective pre- and posttest design, using clinical scenarios and self-reported clinician confidence (Likert scale), and incorporating algorithm feasibility and face validity endpoints. The CASI algorithm was found to significantly increase participants' confidence in the assessment and management of skin injury (P = .002), skin irritation/contact dermatitis (P = .001), and noninfectious exudate (P < .01). A majority of participants reported the algorithm as easy to understand (24/25; 96%), containing all necessary information (24/25; 96%). Twenty-four of 25 (96%) stated that they would recommend the tool to

  18. [Superior vena cava syndrome unrelated to central venous catheter in a patient on chronic hemodialysis].

    PubMed

    Veronesi, Marco; Mancini, Elena; Salvati, Filippo; Santoro, Antonio

    2011-01-01

    A 67-year-old woman with end-stage renal disease (polycystic kidney disease) who had been on dialysis for 10 years came to our department for a second opinion about upper left arm edema homolateral to the arteriovenous fistula (AVF). Because of the suspicion of venous stenosis she had already been submitted to angiographic examination of the AVF which, however, did not show any occlusive process. In addition to the kidney problem, the clinical history included dilated cardiomyopathy, and 2 years earlier a biventricular implantable cardioverter defibrillator (ICD) had been placed. The patient had never had a central venous catheter (CVC). She presented a typical superior vena cava syndrome picture with arm, neck and hemifacial edema and superficial cutaneous venous reticulum. The venous pressure during extracoroporeal circulation was high and blood recirculation was documented. Angio-CT was performed to look for a compressive process in the chest, but this was excluded. We then performed a new trans-AVF angiography to study extensively the axillary-subclavian-superior vena cava district. At first, no stenosis or thrombosis was observed, but the presence of ICD and its leads (left-sided implanted) in the anonymous vein created obstacles to diagnosis. Repeated injections of contrast medium and focusing imaging on the leads route allowed us to highlight a venous stenosis in the anonymous vein. Transluminal angioplasty was successfully carried out during the same procedure. 1) In hemodialysis patients the appearance of signs of intrathoracic vein drainage obstacles is not always associated with previous CVC implantation; 2) in the hemodialysis patient, any device (PM, ICD) should be implanted contralaterally to the fistula arm in order to avoid the risk that a venous stenosis may cause AVF dysfunction.

  19. A failure of preoperative duplex imaging to diagnose a lower extremity venous aneurysm in a patient with severe chronic venous insufficiency.

    PubMed

    Jones, Roy Wesley; Parkerson, Godfrey Ross; Ottinger, Mary; Rodriguez, Eduardo; Park, Brian

    2017-01-01

    We present a case of recurrent bilateral lower extremity venous stasis ulcers in association with a superficial venous aneurysm at the right saphenofemoral junction that was misdiagnosed on preoperative duplex scanning. A 53-year-old female presented to our clinic with 6-year history of bilateral lower extremity venous stasis ulcers. Her past medical history was significant for refractory venous stasis ulcers of the bilateral lower extremities present for 6 years and morbid obesity. Preoperative venous duplex demonstrated severe venous insufficiency of the superficial and deep systems, but a venous aneurysm was not appreciated. During the high ligation of the right saphenofemoral junction, a 3 × 4 × 5 cm aneurysm was encountered. Repair consisted of aneurysm resection, high ligation of the greater saphenous vein, dissociation of the great saphenous and anterior saphenous veins, and stab phlebectomy of large varicose veins of the thigh and lower leg. The patient recovered uneventfully and experienced complete healing of the venous stasis ulcer in several weeks. Superficial venous aneurysms of the lower extremity are rare and can be often missed on preoperative duplex ultrasound imaging. Large diameter measurements of the proximal greater saphenous vein and obesity increase the risk of misdiagnosing venous aneurysms with duplex imaging; therefore, clinical suspicion must remain high. These aneurysms can be associated with significant symptoms for which repair is indicated.

  20. 3D conformal MRI-guided transurethral ultrasound therapy: results of gel phantom experiments

    NASA Astrophysics Data System (ADS)

    N'Djin, W. A.; Burtnyk, M.; McCormick, S.; Bronskill, M.; Chopra, R.

    2011-09-01

    MRI-guided transurethral ultrasound therapy shows promise for minimally invasive treatment of localized prostate cancer. Previous in-vivo studies demonstrated the feasibility of performing conservative treatments using real-time temperature feedback to control accurately the establishment of coagulative lesions within circumscribed prostate regions. This in-vitro study tested device configuration and control options for achieving full prostate treatments. A multi-channel MRI compatible ultrasound therapy system was evaluated in gel phantoms using 3 canine prostate models. Prostate profiles were 5 mm-step-segmented from T2-weighted MR images performed during previous in-vivo experiments. During ultrasound exposures, each ultrasound element was controlled independently by the 3D controller. Decisions on acoustic power, frequency, and device rotation rate were made in real time based on MR thermometry feedback and prostate radii. Low and high power treatment approaches using maximum acoustic powers of 10 or 20 W.cm-2 were tested as well as single and dual-frequency strategies (4.05/13.10 MHz). The dual-frequency strategy used either the fundamental frequency or the 3rd harmonic component, depending on the prostate radius. The 20 W.cm-2 dual frequency approach was the most efficient configuration in achieving full prostate treatments. Treatment times were about half the duration of those performed with 10 W.cm-2 configurations. Full prostate coagulations were performed in 16.3±6.1 min at a rate of 1.8±0.2 cm3.min-1, and resulted in very little undertreated tissue (<3%). Surrounding organs positioned beyond a safety distance of 1.4±1.0 mm from prostate boundaries were not damaged, particularly rectal wall tissues. In this study, a 3D, MR-thermometry-guided transurethral ultrasound therapy was validated in vitro in a tissue-mimicking phantom for performing full prostate treatment. A dual-frequency configuration with 20 W.cm-2 ultrasound intensity exposure showed good

  1. Primary malignant tumours of the bony pelvis: US-guided high intensity focused ultrasound ablation.

    PubMed

    Wang, Yang; Wang, Wei; Tang, Jie

    2013-11-01

    The aim of this review is to evaluate the value of ultrasound (US)-guided high intensity focused ultrasound (HIFU) ablation in the treatment of primary malignant tumours of the bony pelvis. Eleven patients with primary malignant tumours of the bony pelvis received US-guided HIFU ablation. The maximum tumour size ranged from 5.6 to 25.0 cm (median 10.5 cm). Treatment was curative in four patients and palliative in seven patients. During follow-up, the effectiveness of HIFU ablation was assessed by contrast-enhanced magnetic resonance (MR). Significant coagulative necrosis was obtained in all patients after scheduled HIFU ablations; the volume ablation ratio was 86.7% ± 12.5% (range 65-100%). Complete tumour necrosis was achieved in all patients receiving curative HIFU ablation. No major complications were encountered. No patients died of local tumour progression during follow-up. US-guided HIFU ablation may be a safe and effective minimally invasive technique for the local treatment of primary malignant tumours of the bony pelvis.

  2. Ultrasound-guided vs endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer diagnosis

    PubMed Central

    Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao

    2013-01-01

    AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631

  3. Central venous pressure and mean circulatory filling pressure in the dogfish Squalus acanthias: adrenergic control and role of the pericardium.

    PubMed

    Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P

    2006-11-01

    Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.

  4. Use of peripherally inserted central venous catheters (PICCs) in children receiving autologous or allogeneic stem-cell transplantation.

    PubMed

    Benvenuti, Stefano; Ceresoli, Rosanna; Boroni, Giovanni; Parolini, Filippo; Porta, Fulvio; Alberti, Daniele

    2018-03-01

    The aim of our study was to present our experience with the use of peripherally inserted central catheters (PICCs) in pediatric patients receiving autologous or allogenic blood stem-cell transplantation. The insertion of the device in older children does not require general anesthesia and does not require a surgical procedure. From January 2014 to January 2017, 13 PICCs were inserted as a central venous device in 11 pediatric patients submitted to 14 autologous or allogeneic stem-cell transplantation, at the Bone Marrow Transplant Unit of the Children's Hospital of Brescia. The mean age of patients at the time of the procedure was 11.3 years (range 3-18 years). PICCs remained in place for an overall period of 4104 days. All PICCs were positioned by the same specifically trained physician and utilized by nurses of our stem-cell transplant unit. No insertion-related complications were observed. Late complications were catheter ruptures and line occlusions (1.2 per 1000 PICC days). No rupture or occlusion required removal of the device. No catheter-related venous thrombosis, catheter-related bloodstream infection (CRBSI), accidental removal or permanent lumen occlusion were observed. Indications for catheter removal were completion of therapy (8 patients) and death (2 patients). Three PICCs are currently being used for blood sampling in follow-up patients after transplantation. Our data suggest that PICCs are a safe and effective alternative to conventional central venous catheters even in pediatric patients with high risk of infectious and hemorrhagic complications such as patients receiving stem-cell transplantation.

  5. Ultrasound-Guided Pulsed Radiofrequency Stimulation of Posterior Tibial Nerve: A Potential Novel Intervention for Recalcitrant Plantar Fasciitis.

    PubMed

    Wu, Yung-Tsan; Chang, Chih-Ya; Chou, Yu-Ching; Yeh, Chun-Chang; Li, Tsung-Ying; Chu, Heng-Yi; Chen, Liang-Cheng

    2017-05-01

    To evaluate the therapeutic benefit of ultrasound-guided pulsed radiofrequency (PRF) stimulation at the posterior tibial nerve (PTN) in patients with recalcitrant plantar fasciitis (PF). A prospective, randomized, double-blinded, placebo-controlled trial (12-wk follow-up). Outpatient local medical center settings. Patients (N=36) with recalcitrant PF underwent randomization, and all were included in the final data analysis. Patients in the PRF group were treated with 1 dose of ultrasound-guided PRF stimulation at the PTN, and those in the control group received 1 dose of 2% lidocaine, 0.5mL, injected at the PTN under ultrasound guidance. The visual analog scale (first-step and overall pain), American Orthopedic Foot-Ankle Society (AOFAS) ankle-hindfoot scale, and ultrasonographic thickness of the plantar fascia were evaluated at 1, 4, 8, and 12 weeks after treatment. Thirty-six patients (20 feet per group) completed the study. The PRF group had a significantly larger improvement in first-step pain, overall pain, and AOFAS score (all P<.001), as well as plantar fascia thickness (P<.05), compared with those of the control group at all observed time points. This study shows that ultrasound-guided PRF stimulation at the PTN is effective for treating recalcitrant PF. This simple, reproducible method could be a novel strategy for managing recalcitrant PF. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. Ultrasound guided transarterial coil placement in the internal and external carotid artery in horses.

    PubMed

    Muñoz, Juan; Iglesias, Manuel; Chao, Eduardo Lloret; Bussy, Christian

    2015-04-01

    To assess ultrasound guided transarterial coil placement (UGTACP) for occlusion of the internal carotid artery (ICA) and external carotid artery (ECA) in horses. Cadaveric and in vivo study. Cadaveric horses (n = 10), healthy horses (3), and 1 clinical case. Cadaveric and in vivo (healthy horses): UGTACP was performed in the caudal part of the ICA and ECA. Coil placement in the rostral part of the ICA was performed blindly and controlled by conventional radiography. No coils were placed in the rostral part of the ECA. UGTACP of the ICA was in a horse with guttural pouch mycosis of the left guttural pouch. Accurate ultrasound-guided catheterization of the ICA and ECA was performed in all specimens. Ultrasound-guided coil placement was successfully performed in all cases except 1. No complications occurred in the in vivo study. The clinical case fully recovered and returned to its intended use. Based on our study, UGTACP of the ICA and ECA caudal part is a feasible alternative to fluoroscopy. An advantage of this technique is the accuracy with which you can catheterize both ICA and ECA and the ability to identify unusual branching at the origin of the ICA. Regarding the rostral part of the ICA, angiographic catheter guidance in this region is probably more precise using fluoroscopy as it is performed blindly. In a clinical situation, combination of US and fluoroscopy guidance can result in reduction of radiation exposure time. © Copyright 2014 by The American College of Veterinary Surgeons.

  7. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    PubMed

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  8. Intracardiac electrocardiography via a "saline-filled central venous catheter electrocardiographic lead": a historical perspective.

    PubMed

    Madias, John E

    2004-04-01

    The author describes his experience with a "saline-filled central venous catheter electrocardiographic lead" for the recording of intracardiac electrocardiograms provides a brief description of the methodology, refers to this modality's clinical usefulness, furnishes 2 examples illustrating the contribution of the method to clinical diagnosis, and outlines his literature search to find the discoverer/originator of the employment of a saline-filled intracardiac catheter as an electrocardiogram recording lead.

  9. Prospective randomized trial comparing magnetic resonance imaging (MRI)-guided in-bore biopsy to MRI-ultrasound fusion and transrectal ultrasound-guided prostate biopsy in patients with prior negative biopsies.

    PubMed

    Arsov, Christian; Rabenalt, Robert; Blondin, Dirk; Quentin, Michael; Hiester, Andreas; Godehardt, Erhard; Gabbert, Helmut E; Becker, Nikolaus; Antoch, Gerald; Albers, Peter; Schimmöller, Lars

    2015-10-01

    A significant proportion of prostate cancers (PCas) are missed by conventional transrectal ultrasound-guided biopsy (TRUS-GB). It remains unclear whether the combined approach using targeted magnetic resonance imaging (MRI)-ultrasound fusion-guided biopsy (FUS-GB) and systematic TRUS-GB is superior to targeted MRI-guided in-bore biopsy (IB-GB) for PCa detection. To compare PCa detection between IB-GB alone and FUS-GB + TRUS-GB in patients with at least one negative TRUS-GB and prostate-specific antigen ≥4 ng/ml. Patients were prospectively randomized after multiparametric prostate MRI to IB-GB (arm A) or FUS-GB + TRUS-GB (arm B) from November 2011 to July 2014. The study was powered at 80% to demonstrate an overall PCa detection rate of ≥60% in arm B compared to 40% in arm A. Secondary endpoints were the distribution of highest Gleason scores, the rate of detection of significant PCa (Gleason ≥7), the number of biopsy cores to detect one (significant) PCa, the positivity rate for biopsy cores, and tumor involvement per biopsy core. The study was halted after interim analysis because the primary endpoint was not met. The trial enrolled 267 patients, of whom 210 were analyzed (106 randomized to arm A and 104 to arm B). PCa detection was 37% in arm A and 39% in arm B (95% confidence interval for difference, -16% to 11%; p=0.7). Detection rates for significant PCa (29% vs 32%; p=0.7) and the highest percentage tumor involvement per biopsy core (48% vs 42%; p=0.4) were similar between the arms. The mean number of cores was 5.6 versus 17 (p<0.001). A limitation is the limited number of patients because of early cessation of accrual. This trial failed to identify an important improvement in detection rate for the combined biopsy approach over MRI-targeted biopsy alone. A prospective comparison between MRI-targeted biopsy alone and systematic TRUS-GB is justified. Our randomized study showed similar prostate cancer detection rates between targeted prostate biopsy

  10. Assessment of Venous Thrombosis in Animal Models.

    PubMed

    Grover, Steven P; Evans, Colin E; Patel, Ashish S; Modarai, Bijan; Saha, Prakash; Smith, Alberto

    2016-02-01

    Deep vein thrombosis and common complications, including pulmonary embolism and post-thrombotic syndrome, represent a major source of morbidity and mortality worldwide. Experimental models of venous thrombosis have provided considerable insight into the cellular and molecular mechanisms that regulate thrombus formation and subsequent resolution. Here, we critically appraise the ex vivo and in vivo techniques used to assess venous thrombosis in these models. Particular attention is paid to imaging modalities, including magnetic resonance imaging, micro-computed tomography, and high-frequency ultrasound that facilitate longitudinal assessment of thrombus size and composition. © 2015 American Heart Association, Inc.

  11. Real-time ultrasound-guided PCNL using a novel SonixGPS needle tracking system.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; Dalin, He; He, Hui

    2014-08-01

    SonixGPS is a successful ultrasound guidance position system. It helps to improve accuracy in performing complex puncture operations. This study firstly used SonixGPS to perform kidney calyx access in PCNL to investigate its effectiveness and safety. This was a prospectively randomized controlled study performed from September 2011 to October 2012. A total of 97 patients were prospectively randomized into two groups using random number generated from SAS software. 47 Patients were enrolled in conventional ultrasound-guided (US-guided) group and 50 patients were classified into SonixGPS-guided group. Nine patients were lost during follow-up. Hence, a total of 88 patients were qualified and analyzed. Preoperative examinations included urine analysis, urine culture, kidney function, coagulation profile and routine analysis of blood. Ultrasonography was used to evaluate the degree of hydronephrosis. The intraoperative findings, including blood loss, operating time, time to successful puncture, the number of attempts for successful puncture and hospital stay were recorded. The stone clearance rate and complications were analyzed. The present study showed no significant difference between the two groups in terms of demographic data, preoperative markers, stone clearance rate and the stone composition. However, the time to successful puncture, the number of trials for successful puncture, operating time and hospital length of stay were significantly decreased in the SonixGPS-guided group. Furthermore, the hemoglobin decrease was also obviously lower in the SonixGPS group than that in conventional US-guided group. SonixGPS needle tacking system guided PCNL is safe and effective in treating upper urinary tract stones. This novel technology makes puncturing more accuracy and can significantly decrease the incidence of relative hemorrhage and accelerate recovery.

  12. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    PubMed

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  13. Pathological fracture of the patella due to an atypical located aneurysmal bone cyst: verification by means of ultrasound-guided biopsy.

    PubMed

    Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander

    2016-03-01

    We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.

  14. Ultrasound-guided drainages and sclerotherapy.

    PubMed

    Lohela, P

    2002-02-01

    Ultrasonically guided fluid collection and abscess drainage have become routine procedures in various parts of the body. In most cases ultrasound is the only imaging and guidance modality needed; however, it is of the utmost importance to remember that CT and fluoroscopy with contrast often give invaluable information when the true extent of the process has to be determined and when assessing the safest route for the catheter in anatomically complicated areas. The importance of irrigation of the abscess cavity with fluids and the ready use of urokinase should be emphasized. Ethanol sclerotherapy is a simple and safe procedure to treat symptomatic hepatic or renal cysts. Parathyroid adenomas and cysts, as well as thyroid cysts, can also be treated with ethanol sclerotherapy in selected cases. Purified mineral talc has been used in pleurodesis and hydrocele sclerotherapy, whereas doxycycline or ethanol is used for postoperative lymphoceles. Both abscess drainages and sclerotherapy procedures are minimally invasive, simple, safe, inexpensive and reasonably efficacious treatment in many clinical instances and may be at least an alternative to surgical treatment, often offering significant advantages over surgery.

  15. MRI-Guided Focused Ultrasound Surgery

    PubMed Central

    Jolesz, Ferenc A.

    2014-01-01

    MRI-guided focused ultrasound (MRgFUS) surgery is a noninvasive thermal ablation method that uses magnetic resonance imaging (MRI) for target definition, treatment planning, and closed-loop control of energy deposition. Integrating FUS and MRI as a therapy delivery system allows us to localize, target, and monitor in real time, and thus to ablate targeted tissue without damaging normal structures. This precision makes MRgFUS an attractive alternative to surgical resection or radiation therapy of benign and malignant tumors. Already approved for the treatment of uterine fibroids, MRgFUS is in ongoing clinical trials for the treatment of breast, liver, prostate, and brain cancer and for the palliation of pain in bone metastasis. In addition to thermal ablation, FUS, with or without the use of microbubbles, can temporarily change vascular or cell membrane permeability and release or activate various compounds for targeted drug delivery or gene therapy. A disruptive technology, MRgFUS provides new therapeutic approaches and may cause major changes in patient management and several medical disciplines. PMID:19630579

  16. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    PubMed

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Acute Calcific Bursitis After Ultrasound-Guided Percutaneous Barbotage of Rotator Cuff Calcific Tendinopathy: A Case Report.

    PubMed

    Kang, Bo-Sung; Lee, Seung Hak; Cho, Yung; Chung, Sun Gun

    2016-08-01

    Ultrasound-guided percutaneous barbotage is an effective treatment for rotator cuff calcific tendinopathy, providing rapid and substantial pain relief. We present the case of a 49-year-old woman with aggravated pain early after ultrasound-guided barbotage of a large calcific deposit in the supraspinatus tendon. Subsequent examination revealed a thick calcification spreading along the subacromial-subdeltoid bursa space, suggesting acute calcific bursitis complicated by barbotage. Additional barbotage alleviated her pain completely. Therefore, a high index of suspicion for acute calcific bursitis is required in patients with unresolved or aggravated pain after barbotage. Repeated barbotage could be effective for this condition. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  18. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    PubMed

    Spiliopoulos, S; Katsanos, K; Diamantopoulos, A; Karnabatidis, D; Siablis, D

    2011-05-01

    To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Between January 2009 and 2010, 200 patients (161 men, mean age 63±12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6±1.6 versus 4.6±1.9, p<0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16±2.7 versus 19±0.8ml, p<0.001).Total vascular access time was similar in both groups (4.4±1.3 versus 4.5±1.3min). Overall complications included two small groin haematomas in each group. Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.

    PubMed

    Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman

    2013-10-01

    Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.

  20. Open heart surgery for management of right auricular thrombus related to central venous catheterization.

    PubMed

    Ribeiro, A F; Neto, I S; Maia, I; Dias, C

    2018-04-19

    Central venous catheters are widely used in critically ill patients; however, they are also associated with increased morbidity and mortality. The literature may underestimate the incidence of catheter-inducible right atrial thrombi that are asymptomatic but potentially life threatening. The recognized risk factors for its development include infections related to the catheter, endothelial injury secondary to mechanical and chemical damage induced by certain medications and infused fluids. The characteristics of the patient and the catheter, such as size, material, type, location and ease of insertion, as well as the duration of placement play an additional role. We report the case of a 38-year-old man, who developed an asymptomatic catheter-inducible right atrial thrombi requiring open heart surgery, after taking a central venous catheter for thirty-five days. The present case highlights existing limitations in making a correct and fast diagnosis, which should be anticipated in patients with multiple risk factors for thrombosis. Given the limited recommendations available, we consider that the most appropriate strategy should be individualized. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Effect of abdominal liposuction on sonographically guided high-intensity focused ultrasound ablation.

    PubMed

    Zhao, Wen-Peng; Chen, Jin-Yun; Chen, Wen-Zhi

    2014-09-01

    The aim of this study was to evaluate the effect of abdominal liposuction on sonographically guided high-intensity focused ultrasound (HIFU) ablation. A total of 10 women with uterine fibroids or adenomyosis who had received abdominal liposuction were analyzed after sonographically guided HIFU ablation. Of the 10 women, 6 had a diagnosis of uterine fibroids, and 4 had a diagnosis of uterine adenomyosis. All of them had a history of a horizontal-margin split-cesarean delivery. In addition, 26 women with a history of a single horizontal-margin split-cesarean delivery who had a diagnosis of uterine fibroids or adenomyosis but had not received liposuction were analyzed together as a control group. Of the 10 women, 1 woman with uterine fibroids developed local skin erythema after treatment; 1 women with uterine adenomyosis developed a skin burn after treatment; and the remaining women had obvious skin-burning pain during treatment. All women who had not received liposuction finished the treatment with no serious adverse events during or after treatment. The pain scores and incidence of skin-burning pain were significantly higher in the liposuction group than the control group (P= .021 and .038, respectively). Abdominal liposuction may increase the risk of skin burns during sonographically guided HIFU ablation. © 2014 by the American Institute of Ultrasound in Medicine.

  2. Defining the reliability of sonoanatomy identification by novices in ultrasound-guided pediatric ilioinguinal and iliohypogastric nerve blockade.

    PubMed

    Ford, Simon; Dosani, Maryam; Robinson, Ashley J; Campbell, G Claire; Ansermino, J Mark; Lim, Joanne; Lauder, Gillian R

    2009-12-01

    The ilioinguinal (II)/iliohypogastric (IH) nerve block is a safe, frequently used block that has been improved in efficacy and safety by the use of ultrasound guidance. We assessed the frequency with which pediatric anesthesiologists with limited experience with ultrasound-guided regional anesthesia could correctly identify anatomical structures within the inguinal region. Our primary outcome was to compare the frequency of correct identification of the transversus abdominis (TA) muscle with the frequency of correct identification of the II/IH nerves. We used 2 ultrasound machines with different capabilities to assess a potential equipment effect on success of structure identification and time taken for structure identification. Seven pediatric anesthesiologists with <6 mo experience with ultrasound-guided regional anesthesia performed a total of 127 scans of the II region in anesthetized children. The muscle planes and the II and IH nerves were identified and labeled. The ultrasound images were reviewed by a blinded expert to mark accuracy of structure identification and time taken for identification. Two ultrasound machines (Sonosite C180plus and Micromaxx, both from Sonosite, Bothell, WA) were used. There was no difference in the frequency of correct identification of the TA muscle compared with the II/IH nerves (chi(2) test, TA versus II, P = 0.45; TA versus IH, P = 0.50). Ultrasound machine selection did show a nonsignificant trend in improving correct II/IH nerve identification (II nerve chi(2) test, P = 0.02; IH nerve chi(2) test, P = 0.04; Bonferroni corrected significance 0.17) but not for the muscle planes (chi(2) test, P = 0.83) or time taken (1-way analysis of variance, P = 0.07). A curve of improving accuracy with number of scans was plotted, with reliability of TA recognition occurring after 14-15 scans and II/IH identification after 18 scans. We have demonstrated that although there is no difference in the overall accuracy of muscle plane versus II

  3. Ultrasound-guided microinjection into the mouse forebrain in utero at E9.5.

    PubMed

    Pierfelice, Tarran J; Gaiano, Nicholas

    2010-11-13

    In utero survival surgery in mice permits the molecular manipulation of gene expression during development. However, because the uterine wall is opaque during early embryogenesis, the ability to target specific parts of the embryo for microinjection is greatly limited. Fortunately, high-frequency ultrasound imaging permits the generation of images that can be used in real time to guide a microinjection needle into the embryonic region of interest. Here we describe the use of such imaging to guide the injection of retroviral vectors into the ventricular system of the mouse forebrain at embryonic day (E) 9.5. This method uses a laparotomy to permit access to the uterine horns, and a specially designed plate that permits host embryos to be bathed in saline while they are imaged and injected. Successful surgeries often result in most or all of the injected embryos surviving to any subsequent time point of interest (embryonically or postnatally). The principles described here can be used with slight modifications to perform injections into the amnionic fluid of E8.5 embryos (thereby permitting infection along the anterior posterior extent of the neural tube, which has not yet closed), or into the ventricular system of the brain at E10.5/11.5. Furthermore, at mid-neurogenic ages (~E13.5), ultrasound imaging can be used direct injection into specific brain regions for viral infection or cell transplantation. The use of ultrasound imaging to guide in utero injections in mice is a very powerful technique that permits the molecular and cellular manipulation of mouse embryos in ways that would otherwise be exceptionally difficult if not impossible.

  4. [Assertiveness and peripheral intravenous catheters dwell time with ultrasonography-guided insertion in children and adolescents].

    PubMed

    Avelar, Ariane Ferreira Machado; Peterlini, Maria Angélica Sorgini; da Pedreira, Mavilde Luz Gonçalves

    2013-06-01

    Randomized controlled trial which aimed to verify whether the use of vascular ultrasound (VUS) increases assertiveness in the use of peripheral venous catheter in children, and the catheter dwell time, when compared to traditional puncture. Data were collected after approval of theethical merit. Children and adolescents undergoing VUS-guided peripheral intravenous (GVUS) or puncture guided by clinical assessment of the venous conditions(CG) were included in the study. Significance level was set at p< or =0.05. The sample was composed of 382 punctures, 188 (49.2%) in VUS Gand 194 (50.8%) in CG, performed in 335 children. Assertiveness was found in 73 (71.6%) GVUS catheters and in 84(71.8%) of the CG (p=0.970), and catheter dwell time presented a median of less than one day in both groups (p=0.121), showing nostatistically significant difference. VUS did not significantly influence the results of the dependent variables investigated. ClinicalTrials.govNCT00930254.

  5. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    NASA Astrophysics Data System (ADS)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  6. An orthopedist's guide to shoulder ultrasound: a systematic review of examination protocols.

    PubMed

    Amoo-Achampong, Kelms; Nwachukwu, Benedict U; McCormick, Frank

    2016-11-01

    The utilization of musculoskeletal ultrasound has expanded within the setting of the orthopedic clinic as a cost-effective, point-of-care diagnostic tool for shoulder pathology. In experienced hands, ultrasound exhibits capabilities equivalent to that of magnetic resonance imaging in the diagnosis of many shoulder diseases including full-thickness and partial-thickness rotator cuff tears. Although similarly effective in identifying additional shoulder disease processes, major obstacles to its widespread use include user dependence and intrinsic limitation to extra-articular diagnosis. The purpose of this review is to present a step-by-step guide of how to perform a comprehensive shoulder examination and to discuss the appropriate use, economic benefit and implementation of ultrasound within the clinic. A systematic search (June 2016) of PubMed, Scopus, and EMBASE databases was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for literature presenting shoulder ultrasound examination protocols. Included studies were peer-reviewed articles or academic society endorsed protocols presenting comprehensive sonographic examinations of the adult shoulder. Papers with limited or single structure examination descriptions, non-English language, and publication dates before 1980 were excluded. Final papers meeting criteria were secondarily screened for publication after 2005 to reflect the current state of ultrasound imaging. The search yielded 1,725 unique articles with 17 studies meeting final selection criteria. Information from identified studies was summarized to formulate a 4-part shoulder examination protocol, including steps most pertinent to orthopedic in-office diagnoses. In agreement with previous studies, the inexperienced orthopedic surgeon can be quickly trained to expert level proficiency in shoulder ultrasound diagnosis. Using an established protocol, a comprehensive, yet effective shoulder

  7. Management of mediastinal syndromes in pediatrics: a new challenge of ultrasound guidance to avoid high-risk general anesthesia.

    PubMed

    Sola, Chrystelle; Choquet, Olivier; Prodhomme, Olivier; Capdevila, Xavier; Dadure, Christophe

    2014-05-01

    Adverse events associated with anesthetic management of anterior mediastinal masses in pediatrics are common. To avoid an extremely hazardous general anesthesia, the use of real-time ultrasonography offers an effective alternative in high-risk cases. We report the anesthetic management including a light sedation and ultrasound guidance for regional anesthesia, surgical node biopsy, and placement of a central venous line in two children with an anterior symptomatic mediastinal mass. For pediatric patients with clinical and/or radiologic signs of airway compression, ultrasound guidance provides safety technical assistance to avoid general anesthesia and should be performed for the initial diagnostic and therapeutic procedures. © 2013 John Wiley & Sons Ltd.

  8. A Randomized Controlled Comparison of the Internal Jugular Vein and the Subclavian Vein as Access Sites for Central Venous Catheterization in Pediatric Cardiac Surgery.

    PubMed

    Camkiran Firat, Aynur; Zeyneloglu, Pinar; Ozkan, Murat; Pirat, Arash

    2016-09-01

    To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. A 1:1 randomized controlled trial. Baskent University Medical Center. Pediatric patients scheduled for cardiac surgery. Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and

  9. Assessment of central venous catheter colonization using surveillance culture of withdrawn connectors and insertion site skin.

    PubMed

    Pérez-Granda, María Jesús; Guembe, María; Cruces, Raquel; Barrio, José María; Bouza, Emilio

    2016-02-02

    Culture of catheter hubs and skin surrounding the catheter entry site has a negative predictive value for catheter tip colonization. However, manipulation of the hub for culture requires the hubs to be swabbed, introducing potential dislodging of biofilm and subsequent migration of microorganisms. Hubs are usually closed with needleless connectors (NCs), which are replaced regularly. Our objective was to evaluate whether culture of flushed withdrawn NCs is an alternative to hub culture when investigating central venous catheter colonization. The study population comprised 49 intensive care unit patients whose central venous catheters had been in place for at least 7 days. Cultures of NCs and skin were obtained weekly. We included 82 catheters with more than 7 days' indwelling time. The catheter tip colonization rate was 18.3% (15/82). Analysis of skin and NC cultures revealed a 92.5% negative predictive value for catheter colonization. Three episodes of catheter-related bloodstream infection (C-RBSI) occurred in patients with colonized catheters. Surveillance of NC and skin cultures could help to identify patients at risk for C-RBSI.

  10. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    García-Medina, J., E-mail: josegmedina57@gmail.com; García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance ismore » feasible and safe in roughly two-thirds of cases.« less

  11. Theoretical Analysis of the Accuracy and Safety of MRI-Guided Transurethral 3-D Conformal Ultrasound Prostate Therapy

    NASA Astrophysics Data System (ADS)

    Burtnyk, Mathieu; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound therapy is a promising new approach for the treatment of localized prostate cancer. Several studies have demonstrated the feasibility of producing large regions of thermal coagulation adequate for prostate therapy; however, the quantitative assessment of shaping these regions to complex 3-D human prostate geometries has not been fully explored. This study used numerical simulations and twenty manually-segmented pelvic anatomical models derived from high-quality MR images of prostate cancer patients to evaluate the treatment accuracy and safety of 3-D conformal MRI-guided transurethral ultrasound therapy. The simulations incorporated a rotating multi-element planar dual-frequency ultrasound transducer (seventeen 4×3 mm elements) operating at 4.7/9.7 MHz and 10 W/cm2 maximum acoustic power. Results using a novel feedback control algorithm which modulated the ultrasound frequency, power and device rate of rotation showed that regions of thermal coagulation could be shaped to predefined prostate volumes within 1.0 mm across the vast majority of these glands. Treatment times were typically 30 min and remained below 60 min for large 60 cc prostates. With a rectal cooling temperature of 15° C, the rectal wall did not exceed 30EM43 in half of the twenty patient models with only a few 1 mm3 voxels above this threshold in the other cases. At 4.7 MHz, heating of the pelvic bone can become significant when it is located less than 10 mm from the prostate. Numerical simulations show that MRI-guided transurethral ultrasound therapy can thermally coagulate whole prostate glands accurately and safely in 3-D.

  12. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.

    PubMed

    Baez, E; Huber, A; Vetter, M; Hackelöer, B-J

    2003-03-01

    The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are ultrasound offers the advantage of better preoperative demonstration of the lesions' margins, resulting in better assessment of volumetry, improved intraoperative needle location and perioperative

  13. Ultrasound in regional anaesthesia.

    PubMed

    Griffin, J; Nicholls, B

    2010-04-01

    Ultrasound guidance is rapidly becoming the gold standard for regional anaesthesia. There is an ever growing weight of evidence, matched with improving technology, to show that the use of ultrasound has significant benefits over conventional techniques, such as nerve stimulation and loss of resistance. The improved safety and efficacy that ultrasound brings to regional anaesthesia will help promote its use and realise the benefits that regional anaesthesia has over general anaesthesia, such as decreased morbidity and mortality, superior postoperative analgesia, cost-effectiveness, decreased postoperative complications and an improved postoperative course. In this review we consider the evidence behind the improved safety and efficacy of ultrasound-guided regional anaesthesia, before discussing its use in pain medicine, paediatrics and in the facilitation of neuraxial blockade. The Achilles' heel of ultrasound-guided regional anaesthesia is that anaesthetists are far more familiar with providing general anaesthesia, which in most cases requires skills that are achieved faster and more reliably. To this ends we go on to provide practical advice on ultrasound-guided techniques and the introduction of ultrasound into a department.

  14. Prospective Durability Testing of a Vascular Access Phantom

    DTIC Science & Technology

    2010-09-01

    ultrasound guidance when obtaining central venous access.19,20 The increasing use of ultrasound guidance for vascular access has created an educational...with difficult intravenous access. Ann Emerg Med. 2005;46:456-61. 7. Gallieni M, Cozzolino M. Uncomplicated central vein catheterization of high risk...al. Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: The third sonography

  15. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    PubMed

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  16. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    PubMed

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  17. Deep Needle Procedures: Improving Safety With Ultrasound Visualization

    PubMed Central

    Peabody, Christopher R.; Mandavia, Diku

    2017-01-01

    Abstract Promoting patient safety and increasing health care quality have dominated the health care landscape during the last 15 years. Health care regulators and payers are now tying patient safety outcomes and best practices to hospital reimbursement. Many health care leaders are searching for new technologies that not only make health care for patients safer but also reduce overall health care costs. New advances in ultrasonography have made this technology available to health care providers at the patient’s bedside. Point-of-care ultrasound assistance now aids providers with real-time diagnosis and with visualization for procedural guidance. This is especially true for common deep needle procedures such as central venous catheter insertion, thoracentesis, and paracentesis. There is now mounting evidence that clinician-performed point-of-care ultrasound improves patient safety, enhances health care quality, and reduces health care cost for deep needle procedures. Furthermore, the miniaturization, ease of use, and the evolving affordability of ultrasound have now made this technology widely available. The adoption of point-of-care ultrasonography has reached a tipping point and should be seriously considered the safety standard for all hospital-based deep needle procedures. PMID:24786918

  18. Novel Evidence-Based Classification of Cavernous Venous Occlusive Disease.

    PubMed

    Pathak, Ram A; Rawal, Bhupendra; Li, Zhuo; Broderick, Gregory A

    2016-10-01

    The primary aim of our study was to determine whether an evidence-based rationale could categorize cavernous venous occlusive disease into mild, moderate and severe erectile dysfunction. A total of 863 patients underwent color duplex Doppler ultrasound from January 2010 to June 2013 performed by a single urologist. We identified a cohort of 75 patients (8.7%) with a diagnosis of cavernous venous occlusive disease based on a unilateral resistive index less than 0.9, and right and left peak systolic velocity 35 cm per second or less after visual sexual stimulation. At a median followup of 13 months patients were evaluated for treatment efficacy. A total of 75 patients with a median age of 60 years (range 19 to 83) and a mean body mass index of 26.3 kg/m(2) (range 19.0 to 39.3) satisfied the criteria of cavernous venous occlusive disease. When substratified into tertiles, resistive index cutoffs were obtained, including mild cavernous venous occlusive disease-81.6 to 94.0, moderate disease-72.6 to 81.5 and severe disease-59.5 to 72.5. Using these 3 groups the phosphodiesterase type 5-inhibitor failure rate (p = 0.017) and SHIM (Sexual Health Inventory for Men) score categories (1 to 10 vs 11 to 20, p = 0.030) were statistically significantly different for mild, moderate and severe cavernous venous occlusive disease. Treatment satisfaction was also statistically significantly different. Penile prosthetic placement was a more common outcome among patients with erectile dysfunction and more severe cavernous venous occlusive disease. Our retrospective analysis supports a correlation between the phosphodiesterase type 5 inhibitor failure rate, SHIM score and the rate of surgical intervention using resistive index values. Our data further suggest that an evidence-based classification of cavernous venous occlusive disease by color Doppler ultrasound is possible and can triage patients to penile prosthetic placement. Copyright © 2016 American Urological Association

  19. Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in Humans

    NASA Technical Reports Server (NTRS)

    Watenpaugh, Donald E.

    1996-01-01

    relatively unimportant. Low calf venous compliance probably results from stiffer venous, skeletal muscle, and connective tissues, and better-developed local and central neural controls of venous distensibility. This research establishes that upper-to-lower body reduction of venous compliance can explain headward positioning of the hydrostatic indifference level in humans.

  20. Central States forest management guides as applied in STEMS.

    Treesearch

    Nancy R. Walters

    1988-01-01

    Describes a management prescription system for Central States cover types developed for use in the Central States Stand and Tree Evaluation and Modeling System (STEMS). It includes one management guide for each of the six major cover types in the region. Each guide consists of a decision key that prescribes management, based on stand characteristics and a set of...